WorldWideScience

Sample records for thallium ions

  1. Selective Thallium (I Ion Sensor Based on Functionalised ZnO Nanorods

    Directory of Open Access Journals (Sweden)

    Z. H. Ibupoto

    2012-01-01

    Full Text Available Well controlled in length and highly aligned ZnO nanorods were grown on the gold-coated glass substrate by hydrothermal growth method. ZnO nanorods were functionalised with selective thallium (I ion ionophore dibenzyldiaza-18-crown-6 (DBzDA18C6. The thallium ion sensor showed wide linear potentiometric response to thallium (I ion concentrations ( M to  M with high sensitivity of 36.87 ± 1.49 mV/decade. Moreover, thallium (I ion demonstrated fast response time of less than 5 s, high selectivity, reproducibility, storage stability, and negligible response to common interferents. The proposed thallium (I ion-sensor electrode was also used as an indicator electrode in the potentiometric titration, and it has shown good stoichiometric response for the determination of thallium (I ion.

  2. A calixarene-based ion-selective electrode for thallium(I) detection

    Energy Technology Data Exchange (ETDEWEB)

    Chester, Ryan [Nanochemistry Research Institute, Department of Chemistry, Curtin University, GPO Box U1987, Perth, Western Australia 6845 (Australia); Sohail, Manzar [Faculty of Science, Health, Education and Engineering, University of the Sunshine Coast, Locked Bag 4, Maroochydore DC, Queensland 4556 (Australia); Ogden, Mark I.; Mocerino, Mauro [Nanochemistry Research Institute, Department of Chemistry, Curtin University, GPO Box U1987, Perth, Western Australia 6845 (Australia); Pretsch, Ernö [ETH Zürich, Institute of Biogeochemistry and Pollutant Dynamics (IBP), Universitätstrasse 16, CH-8092, Zürich (Switzerland); De Marco, Roland, E-mail: rdemarc1@usc.edu.au [Nanochemistry Research Institute, Department of Chemistry, Curtin University, GPO Box U1987, Perth, Western Australia 6845 (Australia); Faculty of Science, Health, Education and Engineering, University of the Sunshine Coast, Locked Bag 4, Maroochydore DC, Queensland 4556 (Australia)

    2014-12-03

    Highlights: • Tuning of metal binding cavities in thallium(I) calixarene ionophores. • Novel calixarene-based ionophores with improved selectivity for thallium(I). • Sandwich membrane characterization of thallium(I) binding in novel calixarenes. • Improved selectivity and sensitivity with novel thallium(I) calixarene ionophores. • Solid contact ion-selective electrodes for novel thallium(I) calixarene ionophores. - Abstract: Three new calixarene Tl{sup +} ionophores have been utilized in Tl{sup +} ion-selective electrodes (ISEs) yielding Nernstian response in the concentration range of 10{sup −2}–10{sup −6} M TlNO{sub 3} with a non-optimized filling solution in a conventional liquid contact ISE configuration. The complex formation constants (log β{sub IL}) for two of the calixarene derivatives with thallium(I) (i.e. 6.44 and 5.85) were measured using the sandwich membrane technique, with the other ionophore immeasurable due to eventual precipitation of the ionophore during these long-term experiments. Furthermore, the unbiased selectivity coefficients for these ionophores displayed excellent selectivity against Zn{sup 2+}, Ca{sup 2+}, Ba{sup 2+}, Cu{sup 2+}, Cd{sup 2+} and Al{sup 3+} with moderate selectivity against Pb{sup 2+}, Li{sup +}, Na{sup +}, H{sup +}, K{sup +}, NH{sub 4}{sup +} and Cs{sup +}, noting that silver was the only significant interferent with these calixarene-based ionophores. When optimizing the filling solution in a liquid contact ISE, it was possible to achieve a lower limit of detection of approximately 8 nM according to the IUPAC definition. Last, the new ionophores were also evaluated in four solid-contact (SC) designs leading to Nernstian response, with the best response noted with a SC electrode utilizing a gold substrate, a poly(3-octylthiophene) (POT) ion-to-electron transducer and a poly(methyl methacrylate)–poly(decyl methacrylate) (PMMA–PDMA) co-polymer membrane. This electrode exhibited a slope of 58.4 mV decade

  3. A Novel Ion - selective Polymeric Membrane Sensor for Determining Thallium(I) With High Selectivity

    Science.gov (United States)

    Kassim, Anuar; Rezayi, Majid; Ahmadzadeh, Saeid; Rounaghi, Gholamhossein; Mohajeri, Masoomeh; Azah Yusof, Noor; Tee, Tan Wee; Yook Heng, Lee; Halim Abdullah, Abd

    2011-02-01

    Thallium is a toxic metal that introduced into the environment mainly as a waste from the production of zinc, cadmium, and lead and by combustion of coal. Thallium causes gastrointestinal irritation and nerve damage when people are exposed to it for relatively short period of time. For long term, thallium has the potential to cause the following effects: change in blood chemistry, damage to liver, kidney, intestinal and testicular tissue, and hair loss. In this work a membrane was prepared by use of 4'-nitrobenzo -18-crown-6 (4'NB18C6) as an ion carrier, polyvinylchloride (PVC) as a matrix, and diocthylphetalate (DOP) as a plasticizer for making an ion selective electrode for measurement of Tl+ cation in solutions. The amount of 4'-nitrobenzo-18C6 and polyvinylchloride were optimized in the preparation of the membrane. The response of the electrode was Nernstian within the concentration range 1.0 × 10-8 to 1.0 × 10-1M. This sensor displays a drift in Nernstian response for this cation with increasing the amount of ionophore and decreasing the amount of polyvinylchloride.The results of potentiometric measurements showed that, this electrode also responses to Cu2+ Ni2+ and Pb2+ cations, but the electrode has a wider dynamic range and a lower detection limit to Tl+ cation. The effects of various parameters such as pH, different cations interferences, effect of the amount of ionophore and polyvinylchloride and time on response of the coated ion selective electrode were investigated. Finally the constructed electrode was used in complexometric and precipitation titrations of Tl+ cation with EDTA and KBr, respectively. The response of the fabricated electrode at concentration range from 1.0 × 10-8 to 1.0 × 10-1M is linear with a Nernstian slope of 57.27 mV.

  4. Synthesis and application of a novel nanostructured ion-imprinted polymer for the preconcentration and determination of thallium(I) ions in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Fayazi, M., E-mail: maryamfayazi64@yahoo.com [Young Researchers and Elite Club, Kerman Branch, Islamic Azad University, Kerman (Iran, Islamic Republic of); Ghanei-Motlagh, M. [Young Researchers and Elite Club, Kerman Branch, Islamic Azad University, Kerman (Iran, Islamic Republic of); Taher, M.A. [Department of Chemistry, Faculty of Sciences, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Ghanei-Motlagh, R. [Department of Pathobiology, Faculty of Veterinary Medicine, Ferdowsi University of Mashhad, Mashhad (Iran, Islamic Republic of); Salavati, M.R. [Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad (Iran, Islamic Republic of)

    2016-05-15

    Highlights: • A novel nanostructured thallium(I)-imprinted polymer was evaluated for trace detection of Tl(I). • The prepared sorbent displayed rapid extraction rate, high sensitivity and good reproducibility. • The proposed methodology was applied for quantification of Tl(I) in different water samples. - Abstract: A novel synthesized nanostructured ion-imprinted polymer (IIP) was investigated for the determination of trace amount of thallium(I). For this purpose, the thallium(I) IIP particles were synthesized using methacrylic acid (MAA) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, methyl-2-[2-(2-2-[2-(methoxycarbonyl) phenoxy] ethoxyethoxy) ethoxy] benzoate as the chelating agent and 2,2-azobisisobutyronitrile (AIBN) as the initiator. The prepared IIP particles were characterized by field emission scanning electron microscopy (FE-SEM), Fourier transform infrared spectroscopy (FT-IR) and thermo gravimetric analysis (TGA). Various experimental factors such as pH, the amount of IIP particles, sorption and desorption time, sample volume, elution condition, and potentially interfering ions systematically examined. Under the optimum conditions, a sensitive response to Tl(I) within a wide concentration range (0.05–18 μg L{sup −1}) was achieved. The limit of detection (LOD, 3S{sub b}/m) was 6.3 ng L{sup −1}. The maximum adsorption capacity of the novel imprinted adsorbent for Tl(I) was calculated to be 18.3 mg g{sup −1}. The relative standard deviation (RSD) for eight replicate detections of 0.1 μg L{sup −1} of thallium(I) was found to be 4.0%. An enrichment factor (EF) of 100 was obtained by this method. The proposed technique was successfully applied to monitoring thallium in different water samples and the certified reference material.

  5. Extraction separation of thallium (III) from thallium (I) with n-octylaniline.

    Science.gov (United States)

    Shilimkar, Tulshidas N; Anuse, Mansing A; Patil, Kesharsingh J

    2002-01-01

    A novel method is developed for the extraction separation of thallium(III) from salicylate medium with n-octylaniline dissolved in toluene as an extractant. The optimum conditions have been determined by making a critical study of weak acid concentration, extractant concentration, period of equilibration and effect of solvent on the equilibria. The thallium (III) from the pregnant organic phase is stripped with acetate buffer solution (pH 4.7) and determined complexometrically with EDTA. The method affords the sequential separation of thallium(III) from thallium(I) and also commonly associated metal ions such as Al(III), Ga(III), In(III), Fe(III), Bi(III), Sb(III) and Pb(II). It is used for analysis of synthetic mixtures of associated metal ions and alloys. The method is highly selective, simple and reproducible. The reaction takes place at room temperature and requires 15-20 min for extraction and determination of thallium(III).

  6. Sodium dithionite as a selective demasking agent for the complexometric determination of thallium

    Directory of Open Access Journals (Sweden)

    PRAKASH SHETTY

    2005-11-01

    Full Text Available Sodium dithionite is proposed as a new demasking agent for the rapid and selective complexometric determination of thallium(III. In the presence of diverse metal ions, thallium (III was first complexed with excess EDTA and the surplus EDTAwas then titrated with a standard zinc sulphate solution at pH 5–6 (hexamine buffer using Xylenol Orange as the indicator. The EDTAequivalent to thallium was then released selectively with sodium dithionite and back titrated with a standard zinc sulphate solution as before. Reproducible and accurate results were obtained in the range 4–100 mg of thallium with a relative error of ±27 % and a coefficient of variation (n = 6 of not more than 0.30 %. The effects of various diverse ions were studied. The method was applied to the determination of thallium in its complexes and in alloys.

  7. Extracorporeal treatment for thallium poisoning

    DEFF Research Database (Denmark)

    Ghannoum, Marc; Nolin, Thomas D; Goldfarb, David S

    2012-01-01

    The EXtracorporeal TReatments In Poisoning (EXTRIP) workgroup was formed to provide recommendations on the use of extracorporeal treatment (ECTR) in poisoning. To test and validate its methods, the workgroup reviewed data for thallium (Tl)....

  8. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun [Kosin University College of Medicine, Pusan (Korea, Republic of)

    1994-07-15

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  9. Thallium contamination of water in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Cheam, V. [National Water Research Institute Branch, Burlington, ON (Canada). Aquatic Ecosystems Protection Research Branch

    2001-07-01

    A highly sensitive instrument, a Laser-Excited Atomic Fluorescence Spectrometer, has been developed to study thallium contamination in some important Canadian ecosystems from the Arctic (containing very low thallium concentration) to coal-related industries across Canada and even to the study of thallium toxicity in an invertebrate, Hyalella azteca. Overall, the data indicate that the coal power plants and mines contain higher thallium concentrations than the other ecosystems studied, and the eastern region has the highest Tl concentrations compared to other regions. The range of thallium concentration in ng/L for the Arctic snow and ice was between not detected and 8.4, for the Great Lakes waters 0.9 to 48, for pore waters 0.1 to 213, for western coal power plants and mines 0.1 to 1326, for central coal power plants 1.2 to 175, for eastern coal power plants and mines 0.2 to 23605, and for miscellaneous sites across Canada not detected to 4390 ng/L. Some of these high concentrations and those high ones reported in industrial wastewaters exceeded the chronic toxicity endpoints for Hyalella azteca mortality, growth and reproduction, and thus can cause serious distress to the environment. All data were integrated into a map of thallium distribution, the first one in Canada. Natural background level of thallium for the Arctic was estimated to be 0.02 to 0.03 pg/g.

  10. IRIS Toxicological Review of Thallium and Compounds ...

    Science.gov (United States)

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certain tumors. EPA's assessment of noncancer health effects and carcinogenic potential of thallium compounds was last prepared and added to the IRIS database between 1988 and 1990. The IRIS program is preparing an assessment that will incorporate current health effects information available for thallium and compounds, and current risk assessment methods. The IRIS assessment for thallium compounds will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity in humans and experimental systems. The assessment will present reference values for the noncancer effects of thallium compounds (RfD and Rfc), and a cancer assessment. The Toxicological Review and IRIS Summary have been subject to Agency review, Interagency review, and external scientific peer review. The final product will reflect the Agency opinion on the overall toxicity of thallium and compounds. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for thallium and compounds. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effec

  11. Repeat thallium-201 SPECT in cerebral lymphoma.

    Science.gov (United States)

    Borggreve, F; Dierckx, R A; Crols, R; Mathijs, R; Appel, B; Vandevivere, J; Mariën, P; Martin, J J; De Deyn, P P

    1993-01-01

    The authors report on the contribution of Thallium-201 brain SPECT in the diagnosis and follow-up of a non-immunosuppressed patient, presenting with primary cerebral lymphoma. The tumoral process was at first not diagnosed on CT-scan, but Thallium-201 SPECT suggested a tumoral invasion. During corticosteroid treatment the tumor volume on CT-scan decreased, while on Thallium-201 SPECT there was an enhancement of the accumulation and an increasing tumor to non-tumor ratio. These scintigraphical findings more closely reflected the clinical course and the postmortem results.

  12. Thallium poisoning from maliciously contaminated food.

    Science.gov (United States)

    Meggs, W J; Hoffman, R S; Shih, R D; Weisman, R S; Goldfrank, L R

    1994-01-01

    Four young adults presented two days after one of them had received marzipan balls packaged in a box from an expensive candy manufacturer. Two ate one candy ball, while two others shared a third. The next day, variable gastrointestinal symptoms developed. On the third day, two patients developed painful paresthesiae of the hands and feet, an early but nonspecific clinical marker of thallium poisoning. A tentative diagnosis of thallium poisoning was made based on symptoms, and treatment was initiated. The remaining candies were radiographed. Metallic densities in the candies supported the diagnosis, and atomic absorption spectroscopy was used to quantitate thallium content. Each candy contained a potentially fatal dose. Five to seven days later, hypertension and tachycardia developed in the two patients who had ingested an entire candy. All patients developed alopecia but recovered without overt neurologic or other sequelae. While the diagnosis of thallium poisoning is often delayed until alopecia develops, an early diagnosis favors an effective treatment strategy.

  13. Thallium in mineral resources extracted in Poland

    Directory of Open Access Journals (Sweden)

    Bojakowska I.

    2013-04-01

    Full Text Available Thallium concentrations in primary mineral commodities extracted in Poland and processed in high temperatures were determined by ICP-MS method. Samples of hard and brown coal, copper-silver and zinclead ores, argillaceous and calcareous rocks of different genesis and age were analyzed. The highest thallium concentrations occur in the zinc-lead ores, the average content being of 52.1 mg/kg. The copper ores contain in average 1.4 mg/kg of thallium. Hard coals from the Upper Silesian Coal Basin display higher thallium content than those exploited in the Lublin Coal Basin. Brown coals from Turow deposit distinguish by much higher values, 0.7 mg/kg Tl, than those from huge Bełchatów and smaller Konin-Turek region deposits. Average thallium concentrations in clays used for ceramic materials are lower than 1 mg/kg, except of Mio-Pliocene Slowiany deposit. The average content of thallium in the studied limestone and dolomite raw materials for cement, lime, and metallurgical flux, and refractories is very low in comparison to the average amounts in the world carbonate rocks.

  14. Examining of Thallium in Cigarette Smokers.

    Science.gov (United States)

    Ghaderi, Amir; NasehGhafoori, Payam; Rasouli-Azad, Morad; Sehat, Mojtaba; Mehrzad, Fateme; Nekuei, Mina; Aaseth, Jan; Banafshe, Hamid Reza; Mehrpour, Omid

    2017-08-01

    Smoking is one of the sources of thallium which is considered as a toxic heavy metal. The aim of this study was to determine urinary thallium levels and related variables in smokers, compared to a control group. The study was conducted on 56 participants who had smoked continuously during the year before they were referred to Kashan Smoking Cessation Clinic. Fifty-three nonsmokers who were family members or friends of the smokers were selected as the control group. Urinary thallium was measured in both groups (n = 109) using atomic absorption spectrophotometry. The mean value (with SD) for urinary thallium in the smokers (10.16 ± 1.82 μg/L) was significantly higher than in the control group (2.39 ± 0.63 μg/L). There was a significant relationship between smoking duration and urinary thallium levels (P = 0.003). In a subgroup of smokers who was addicted to opium and opium residues (n = 9), the mean level of thallium (37.5 ± 13.09 μg/L) was significantly higher than in the other smokers (4.93 ± 4.45; P = 0.001). Multiple regression analysis showed opioid abuse, insomnia, and chronic obstructive pulmonary disease (COPD), together were strong predictors of urinary thallium levels in smokers. There was no significant difference in thallium level in hookah smokers (P = 0.299) or in those with COPD compared to other smokers (P = 0.375). Urinary thallium levels of smokers with clinical signs of depression, sleep disorders, memory loss, and sweating were higher than those of smokers without these signs. Since thallium, as other toxic metals is accumulated in the body, and cigarette smoking also involves carcinogenic exposures and health hazards for passively exposed people, the need for cigarette control policies is emphasized.

  15. Complexometric determination of thallium(III using ethanethiol as a selective masking agent

    Directory of Open Access Journals (Sweden)

    Karthikeyan J.

    2006-01-01

    Full Text Available A simple and selective complexometric method for the determination of thallium in presence of other metal ions is proposed based on the selective masking ability of ethanethiol towards thallium(III. Thallium present in a given sample solution is first complexed with a known excess of EDTA and the surplus EDTA is titrated with standard zinc sulphate solution at pH 5-6(hexamine using xylenol orange as the indicator. A 0.3% aqueous solution of ethanethiol is then added to displace EDTA from the Tl(III-EDTA complex. The released EDTA is titrated with standard zinc sulphate solution as before. Reproducible and accurate results are obtained for 3.70 mg to 74.07 mg of Tl (III with relative error less than ? 0.44% and coefficient of variation not more than 0.27%. The interference of various ions was studied and the method was used for the analysis of thallium in its synthetic alloy mixtures and also in complexes.

  16. Thallium-201 scintigraphy in unstable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Wackers, F.J.T.; Lie, K.I.; Liem, K.L.; Sokole, E.B.; Samson, G.; Van Der Schoot, J.B.; Durrer, D.

    1978-04-01

    Thallium-201 scintigraphy was performed during the pain free period in 98 patients with unstable angina. Scintiscans were positive in 39 patients, questionable in 27 patients and normal in 32 patients. Eighty-one patients responded favorably to treatment (group I). Seventeen patients had complicated courses (group II) and despite maximal treatment with propranolol either developed infarction (six patients) or continued to have angina necessitating coronary surgery (11 patients). In group I during the pain free period 26 of 81 patients had positive thallium-201 scans, whereas 20 patients had an abnormal ECG at that time; during angina 18 patients had transient ECG changes. In group II during the pain free period 13 of 17 patients had positive scans, whereas two patients had abnormal ECG at that time; during angina 12 patients showed transient ECG changes. The sensitivity to recognize group II was 76% for thallium-201 scintigraphy, 11% for ECG during the pain free period; 70% for ECG during angina; 94% for the combination of either positive scans or abnormal ECG. Thus, positive thallium-201 scans occur in patients with unstable angina, positive scans can be obtained during the pain free period, thallium-201 scans are more frequently positive in patients with complicated course.

  17. Overlapping toxic effect of long term thallium exposure on white mustard (Sinapis alba L.) photosynthetic activity.

    Science.gov (United States)

    Mazur, Radosław; Sadowska, Monika; Kowalewska, Łucja; Abratowska, Agnieszka; Kalaji, Hazem M; Mostowska, Agnieszka; Garstka, Maciej; Krasnodębska-Ostręga, Beata

    2016-09-02

    Heavy metal exposure affect plant productivity by interfering, directly and indirectly, with photosynthetic reactions. The toxic effect of heavy metals on photosynthetic reactions has been reported in wide-ranging studies, however there is paucity of data in the literature concerning thallium (Tl) toxicity. Thallium is ubiquitous natural trace element and is considered the most toxic of heavy metals; however, some plant species, such as white mustard (Sinapis alba L.) are able to accumulate thallium at very high concentrations. In this study we identified the main sites of the photosynthetic process inhibited either directly or indirectly by thallium, and elucidated possible detoxification mechanisms in S. alba. We studied the toxicity of thallium in white mustard (S. alba) growing plants and demonstrated that tolerance of plants to thallium (the root test) decreased with the increasing Tl(I) ions concentration in culture media. The root growth of plants exposed to Tl at 100 μg L(-1) for 4 weeks was similar to that in control plants, while in plants grown with Tl at 1,000 μg L(-1) root growth was strongly inhibited. In leaves, toxic effect became gradually visible in response to increasing concentration of Tl (100 - 1,000 μg L(-1)) with discoloration spreading around main vascular bundles of the leaf blade; whereas leaf margins remained green. Subsequent structural analyses using chlorophyll fluorescence, microscopy, and pigment and protein analysis have revealed different effects of varying Tl concentrations on leaf tissue. At lower concentration partial rearrangement of the photosynthetic complexes was observed without significant changes in the chloroplast structure and the pigment and protein levels. At higher concentrations, the decrease of PSI and PSII quantum yields and massive oxidation of pigments was observed in discolored leaf areas, which contained high amount of Tl. Substantial decline of the photosystem core proteins and disorder of the

  18. Thallium-201 uptake in a benign thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Campeau, R.J.; Ey, E.H.; Varma, D.G.

    1986-07-01

    A 68-year-old woman was admitted with atypical angina. A chest radiograph showed an anterior mediastinal mass that was confirmed on CT. The mass was relatively avascular and separate from the heart and great vessels. She underwent stress thallium testing that demonstrated no exercise-induced ischemia; however, an abnormal focus of thallium activity was present in the anterior mediastinum on stress and redistribution images. Cardiac catheterization demonstrated a normal left ventriculogram, coronary arteries and thoracic aorta. Subsequent surgery and pathologic examination revealed the mass to be a benign thymoma arising in the right lobe of the thymus gland.

  19. Thallium-201: Autoradiography in pigmented mice and melanin-binding in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Tjaelve, H.; Nilsson, M.; Larsson, B. (Uppsala Univ. (Sweden))

    1982-01-01

    Autoradiography with /sup 201/Tl/sup +/ in C57Bl mice showed a strong labelling of the eye melanin and of pigmented hair follicles. An analysis of the affinity of thallium for pigment from cow eyes indicated a binding to three groups of sites and showed a marked sensitivity to the addition of H/sup +/-ions. The results are consistent with the conception that a binding of thallium occurs to the free carboxyl groups of the melanin and that the structure of the polymer has a marked influence on the affinity. Similar results have previously been obtained with other cations. There was no indication that the strong in vivo affinity of thallium to melanin is due to a more firm binding than for other cations which do not localize on melanin in vivo. Instead, the ability of cations to pass the melanocyte membranes and reach the melanin granules is probably decisive for whether a melanin-binding will take place in vivo. Toxic effects on the eye and epilation are symptoms of thallium intoxication which may be related to its melanin-binding. The fate of /sup 201/Tl/sup +/ in some other tissues is also described and discussed.

  20. Endogenous thiols enhance thallium toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Montes, Sergio; Rios, Camilo [Instituto Nacional de Neurologia y Neurocirugia, ' ' Manuel Velasco Suarez' ' , Departamento de Neuroquimica, Mexico, D.F (Mexico); Soriano, Luz; Monroy-Noyola, Antonio [Universidad Autonoma del Estado de Morelos, Laboratorio de Neuroproteccion, Facultad de Farmacia, Cuernavaca, Morelos (Mexico)

    2007-10-15

    Either L-methionine (L-met) or L-cysteine (L-cys), given alone and in combination with Prussian blue (PB) was characterized as treatment against acute thallium (Tl) toxicity in rats. Animals were intoxicated with 32 mg/kg Tl acetate corresponding to rat LD{sub 50}. Antidotal treatments were administered during 4 days, as follows: (1) vehicle, (2) L-met 100 mg/kg i.p. twice a day, (3) L-cys 100 mg/kg i.p. twice a day, (4) PB 50 mg/kg oral, twice a day, (5) L-met + PB and (6) L-cys + PB. Mortality was as follows: control 50%; L-met 80%; L-cys 80%; PB 20%; L-met + PB 90% and L-cys + PB 100%. In a different experiment, using 16 mg/kg of Tl, tissue levels of this metal were analyzed. PB treatment statistically diminished Tl content in body organs and brain regions (P < 0.01). Whereas, separate treatments of L-met and L-cys failed to decrease Tl content in organs and brain regions; while its administration in combination with PB (L-met + PB and L-cys + PB groups) lowered Tl levels in body organs in the same extent as PB group. Results indicate that L-met and L-cys administered alone or in combination with PB should not be considered suitable treatments against acute Tl toxic effects because this strategy failed to prevent mortality and Tl accumulation in brain. (orig.)

  1. Thallium in fractions of soil formed on floodplain terraces.

    Science.gov (United States)

    Jakubowska, Monika; Pasieczna, Anna; Zembrzuski, Wlodzimierz; Swit, Zbigniew; Lukaszewski, Zenon

    2007-01-01

    Two soils formed on the floodplain terrace of a rivulet flowing through the zinc-lead ore exploration area polluted with thallium and one soil from a floodplain terrace of the reference area were investigated in terms of thallium distribution between soil fractions. Such type of soil is formed on river floodplain terraces next to the main river channel and its composition records the history of river pollution. A sequential extraction of soil according to the BCR protocol was performed with an additional initial stage of extraction with water. Apart from labile thallium, thallium entrapped in the residual parent matter was also determined. Thallium was determined by flow-injection differential-pulse anodic stripping voltammetry. In all three cases, the major fraction is thallium entrapped in parent matter. Top soil from the polluted area contains 49.3% thallium entrapped in the residual parent matter, the bottom soil contains 41% while the reference soil contains 80% in this fraction. The major part of labile thallium is located in the reducible fraction (27.7% of total thallium in the top soil, 27% in the bottom soil and 12.4% of the reference soil). Second in terms of significance is the fraction of oxidizable thallium. The top soil contains 12% of total thallium concentration, the bottom soil contains 19% of total concentration, while the reference soil contains 4.1% of total concentration. The acid soluble/exchangeable fraction of thallium has almost the same significance as the oxidizable fraction. The top soil contains 10.4% of the total concentration, while the bottom soil contains 12% of the total concentration. Water soluble thallium concentration is very small. Comparison of the top and the bottom soil show that thallium has not been transported from the river channel onto the floodplain terrace over a long period.

  2. Thallium Flux Assay for Measuring the Activity of Monovalent Cation Channels and Transporters.

    Science.gov (United States)

    Weaver, C David

    2018-01-01

    Monovalent cation channels are critically important for physiological processes ranging from the control of neuronal excitability to the maintenance of solute balance. Mutations in these channels are associated with a multiplicity of diseases and monovalent cation channel-modulating drugs are used as therapeutics. Techniques that allow the measurement of the activity of these ion channels are useful for exploring their many biological roles as well as enabling the discovery and characterization of ion channel modulators for the purposes of drug discovery. Although there are numerous techniques for measuring the activity of monovalent cation channels, the thallium flux assay technique is a widely used fluorescence-based approach. Described herein is a method for using the thallium-flux technique for detecting and quantifying the activity of small-molecule potassium channel modulators in 384-well plates.

  3. Characteristics of photoconductivity in thallium monosulfide single ...

    Indian Academy of Sciences (India)

    journal of. March 2007 physics pp. 467–479. Characteristics of photoconductivity in thallium monosulfide single crystals. I M ASHRAF, H A ELSHAIKH and A M BADR. Physics Department ... pendencies of carrier lifetime on light intensity, applied voltage and temperature are also ..... 14, 797 (1935) (in Japanese). [10] A T ...

  4. Thallium bromide iodide crystal acoustic anisotropy examination.

    Science.gov (United States)

    Mantsevich, S N

    2017-03-01

    Thallium bromide iodide crystal also known as KRS-5 is the well known material used in far infrared radiation applications for optical windows and lenses fabrication. The main advantage of this material is the transparency in wide band of wavelengths from 0.53 to 50μm. Despite such advantages as transparency and large acousto-optic figure of merit values, KRS-5 is rarely used in acousto-optics. Nevertheless this material seems to be promising for far infrared acousto-optic applications. The acoustic and acousto-optic properties of KRS-5 needed for the full use in optoelectronics are not well understood to date. In this paper the detailed examination of thallium bromide iodide crystal acoustic properties is presented. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Preconcentration of thallium (I) by single drop microextraction with electrothermal atomic absorption spectroscopy detection using dicyclohexano-18-crown-6 as extractant system.

    Science.gov (United States)

    Chamsaz, Mahmoud; Arbab-Zavar, Mohammad Hossien; Darroudi, Abolfazl; Salehi, Thiery

    2009-08-15

    A simple single drop liquid-phase microextraction (SDME) technique, combined with electrothermal atomic absorption spectroscopy (ETAAS) is developed both to preconcentrate and determine thallium (I) ions in aqueous solutions. The ions were transferred from 10.0 ml of aqueous sample (donor phase) containing 0.5 ml of 1% picric acid as the ion-pair agent into a 3 microl microdrop of nitrobenzene (acceptor phase) containing dicyclohexano-18-crown-6 as the complexing agent. The latter will help to improve the extraction efficiency of the analyte. After the ions have been extracted, the acceptor drop was directly injected into a graphite furnace for thallium (I) determination. Several parameters such as the extracting solvent, extraction time, temperature, concentration of picric acid and crown ether, drop volume and stirring rate were examined. Under the optimized experimental conditions, the detection limit (L.O.D.) was 0.7 ng ml(-1). The relative standard deviation for five replicate analysis of 10 ng ml(-1) of thallium (I) was 5.1%. The calibration curve was linear in the range of 3-22 ng ml(-1). The results for determination of thallium in reference material, spiked tap water and seawater demonstrated the accuracy, recovery and applicability of the presented method. The enrichment factor was 50.

  6. Thallium and its contents in Remata carbonate rocks

    Directory of Open Access Journals (Sweden)

    Kondelová Marcela

    1996-09-01

    Full Text Available The article presents at first the list of thallium own minerals and its isomorphic content in other minerals, especially in Slovakian ore deposits. This trace element was found in numerous dolomite-rock samples from Remata massif near Handlová. An interesting level of Tl content was analyzed in nonsilicified rocks; the highest content of Tl (and Ag are along the E – W line of disturbance. The presence of thallium in some limonitic aggregates in close Kremnica-gold deposit indicate any continuous relation. Some similarities to type gold deposits Carlin ( USA are discussed, even if no gold and discrete thallium phases were in Remata determined yet.

  7. Preconcentration of thallium(III) with 2,6-bis( N-phenyl carbamoyl) pyridine on microcrystalline naphthalene prior to its trace determination in human serum spectrophotometrically

    Science.gov (United States)

    Rezaei, B.; Meghdadi, S.; Majidi, N.

    2007-05-01

    A novel, simple, sensitive and effective method has been developed for preconcentration of thallium on 2,6-bis( N-phenyl carbamoyl)pyridine-naphthalene adsorbent in the pH range 5.0-10.0, prior to its spectrophotometric determination, based on the oxidation of bromopyrogallol red at λ = 518 nm. This method makes it possible to quantitize thallium in the range of 3.0 × 10 -9 to 1.0 × 10 -5 M, with a detection limit (S/N = 3) of 1.2 × 10 -9 M. This procedure has been successfully applied to determine the ultra trace levels of thallium in the environmental and biological samples, free from the interference of some diverse ions. The precision, expressed as relative standard deviation of three measurements is better than 4.17%.

  8. Thallium and manganese complexes involved in the luminescence emission of potassium-bearing aluminosilicates

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Gonzalez, Miguel A., E-mail: miguel.gomez@mncn.csic.es [Museo Nacional de Ciencias Naturales, CSIC, Jose Gutierrez Abascal 2, Madrid E-28006 (Spain); Garcia-Guinea, Javier, E-mail: guinea@mncn.csic.es [Museo Nacional de Ciencias Naturales, CSIC, Jose Gutierrez Abascal 2, Madrid E-28006 (Spain); Garrido, Fernando, E-mail: fernando.garrido@mncn.csic.es [Museo Nacional de Ciencias Naturales, CSIC, Jose Gutierrez Abascal 2, Madrid E-28006 (Spain); Townsend, Peter D., E-mail: pdtownsend@gmail.com [School of Science and Technology, University of Sussex, Brighton BN1 9QH (United Kingdom); Marco, Jose-Francisco, E-mail: jfmarco@iqfr.csic.es [Instituto de Química-Física Rocasolano, CSIC, Calle Serrano 119, Madrid E-28006 (Spain)

    2015-03-15

    The luminescence emission at 285 nm in natural K-feldspar has been studied by Russian groups and associated with thallium ions in structural positions of K{sup +} sites as artificially thallium-doped feldspars display the same emission band. Here attention is focussed on spectra of CL emission bands centered near 285 and 560 nm from paragenetic adularia, moscovite and quartz micro-inclusions. With accesorial thallium they show clear resemblances to each other. Associated sedimentary and hydrothermal aluminosilicate samples collected from Guadalix (Madrid, Spain) were analyzed with a wide range of experimental techniques including Environmental Scanning Electron Microscopy (ESEM) with an attached X-Ray Energy-Dispersive Spectrometer (EDS) and a cathodoluminescence probe (CL) and Electron Probe Microanalysis (EPMA), X-Ray Fluorescence Spectrometry (XRF), Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES), Differential and Thermogravimetric Analyses (DTA-TG), radioluminescence (RL), Mössbauer spectroscopy and X-Ray Photoelectron Spectrometry (XPS). The luminescence emission bands at 285 and 560 nm seem to be associated with hydrous thallium–manganese complexes bonded to potassium-bearing aluminosilicates since various minerals such as K-feldspar, moscovite and quartz micro-inclusions display similar CL spectra, accesorial thallium and hydroxyl groups. The presence of iron introduces a brown color which is attributed to submicroscopic iron oxides detectable in the optical and chemical microanalysis, but this does not contribute to the luminescence emission. The XPS Mn 2p spectrum of the adularia sample at room temperature is composed of a spin–orbit doublet plus clear shake-up satellite structure ∼4 eV above the main photoemision lines and is consistent with Mn{sup 2+} in good agreement with the observed luminescence emission at 560 nm for aluminosilicates produced by a {sup 4}T1({sup 4}G)→{sup 6}A1({sup 6}S) transition in tetrahedrally

  9. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry.

    Science.gov (United States)

    Amin, Alaa S; El-Sharjawy, Abdel-Azeem M; Kassem, Mohammed A

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L(-1) of Tl(III) with relative standard deviation (RSD) of 1.40% (n=10). The detection and quantification limits are 150 and 495 ng L(-1) using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31×10(7) L mol(-1)cm(-1) and 0.00156 ng cm(-2), respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. The efficient removal of thallium from sintering flue gas desulfurization wastewater in ferrous metallurgy using emulsion liquid membrane.

    Science.gov (United States)

    Yang, Li; Xiao, Jiangping; Shen, Yi; Liu, Xian; Li, Wensong; Wang, Weiyan; Yang, Yunquan

    2017-11-01

    The removal of thallium ions in flue gas desulfurization wastewater from ferrous metallurgic industry was studied by emulsion liquid membrane (ELM) method using 2-ethylhexyl phosphoric acid-2-ethylhexyl ester (P507) as carrier, aviation kerosene (AK) as organic solvent, polyisobutylene succinimide (T154) as surfactant, polyisobutylene (PIB) as additive, and sulfuric acid as internal reagent. Some important influence parameters such as concentrations of carrier, surfactant and stripping agent, agitation speed, extraction time, volume ratios of feed solution to emulsion phase and internal phase to membrane phase, and their effects on the removal efficiency of Tl in the ELM process were investigated and optimized. Under the optimum operating conditions of 2% of carrier, 5% of surfactant, 0.5 M of stripping agent, 350 rpm of agitation speed, 12.5:1 of volume ratio of feed solution to emulsion phase, and 3:1 volume ratio of membrane to internal phase, the maximum extraction efficiency of thallium reached 99.76% within 15-min reaction time. The ICP-MS analysis indicated that the thallium concentration in treated wastewater was below 5 μg/L and could meet the emission standard demand for industrial wastewater enacted by the local government of Hunan province of China. Meanwhile, the extraction of impurity ions calcium and magnesium in the ELM system was investigated. The result showed that an acidic environment would be in favor of the removal of Tl from calcium and magnesium contained in wastewater. Graphical abstract ᅟ.

  11. [Detecting Thallium in Water Samples using Dispersive Liquid Phase Microextraction-Graphite Furnace Atomic Absorption Spectroscopy].

    Science.gov (United States)

    Zhu, Jing; Li, Yan; Zheng, Bo; Tang, Wei; Chen, Xiao; Zou, Xiao-li

    2015-11-01

    To develope a method of solvent demulsification dispersive liquid phase microextraction (SD-DLPME) based on ion association reaction coupled with graphite furnace atomic absorption spectroscopy (GFAAS) for detecting thallium in water samples. Methods Thallium ion in water samples was oxidized to Tl(III) with bromine water, which reacted with Cl- to form TlCl4-. The ionic associated compound with trioctylamine was obtained and extracted. DLPME was completed with ethanol as dispersive solvent. The separation of aqueous and organic phase was achieved by injecting into demulsification solvent without centrifugation. The extractant was collected and injected into GFAAS for analysis. With palladium colloid as matrix modifier, a two step drying and ashing temperature programming process was applied for high precision and sensitivity. The linear range was 0.05-2.0 microg/L, with a detection limit of 0.011 microg/L. The relative standard derivation (RSD) for detecting Tl in spiked water sample was 9.9%. The spiked recoveries of water samples ranged from 94.0% to 103.0%. The method is simple, sensitive and suitable for batch analysis of Tl in water samples.

  12. Tracing thallium contamination in soils using isotopes

    Science.gov (United States)

    Vaněk, Aleš; Grösslová, Zuzana; Mihaljevič, Martin; Ettler, Vojtěch; Trubač, Jakub; Teper, Leslaw; Cabala, Jerzy; Rohovec, Jan; Penížek, Vít; Zádorová, Tereza; Pavlů, Lenka; Holubík, Ondřej; Drábek, Ondřej; Němeček, Karel; Houška, Jakub; Ash, Christopher

    2017-04-01

    We report the thallium (Tl) isotope record in moderately contaminated soils, which have been historically affected by emissions from coal-fired power plants. Our findings clearly demonstrate that Tl of anthropogenic (high-temperature) origin with light isotope composition was deposited onto the studied soils, where heavier Tl (ɛ205Tl -1) naturally occurs. The results show a positive linear relationship (R2 = 0.71) between 1/Tl and the isotope record, as determined for all the soils and bedrocks, also indicative of binary Tl mixing between two dominant reservoirs. We also identified significant Tl isotope variations within the products from coal combustion and thermo-desorption experiments with local Tl-rich coal pyrite. Bottom ash exhibited the heaviest Tl isotope composition (ɛ205Tl 0), followed by fly ash (ɛ205Tl between -2.5 and -2.8) and volatile Tl fractions (ɛ205Tl between -6.2 and -10.3), suggesting partial Tl isotope fractionations. Despite the evident role of soil processes in the isotope redistribution, we demonstrate that Tl contamination can be traced in soils, and propose that the isotope data represent a possible tool to aid our understanding of post-depositional Tl dynamics in surface environments for the future. This research was supported by the Czech Science Foundation (grant no. 14-01866S and 17-03211S).

  13. Stable room-temperature thallium bromide semiconductor radiation detectors

    Science.gov (United States)

    Datta, A.; Fiala, J.; Becla, P.; Motakef, Shariar

    2017-10-01

    Thallium bromide (TlBr) is a highly efficient ionic semiconductor with excellent radiation detection properties. However, at room temperature, TlBr devices polarize under an applied electric field. This phenomenon not only degrades the charge collection efficiency of the detectors but also promotes chemical reaction of the metal electrodes with bromine, resulting in an unstable electric field and premature failure of the device. This drawback has been crippling the TlBr semiconductor radiation detector technology over the past few decades. In this exhaustive study, this polarization phenomenon has been counteracted using innovative bias polarity switching schemes. Here the highly mobile Br- species, with an estimated electro-diffusion velocity of 10-8 cm/s, face opposing electro-migration forces during every polarity switch. This minimizes the device polarization and availability of Br- ions near the metal electrode. Our results indicate that it is possible to achieve longer device lifetimes spanning more than 17 000 h (five years of 8 × 7 operation) for planar and pixelated radiation detectors using this technique. On the other hand, at constant bias, 2500 h is the longest reported lifetime with most devices less than 1000 h. After testing several biasing switching schemes, it is concluded that the critical bias switching frequency at an applied bias of 1000 V/cm is about 17 μHz. Using this groundbreaking result, it will now be possible to deploy this highly efficient room temperature semiconductor material for field applications in homeland security, medical imaging, and physics research.

  14. Stable room-temperature thallium bromide semiconductor radiation detectors

    Directory of Open Access Journals (Sweden)

    A. Datta

    2017-10-01

    Full Text Available Thallium bromide (TlBr is a highly efficient ionic semiconductor with excellent radiation detection properties. However, at room temperature, TlBr devices polarize under an applied electric field. This phenomenon not only degrades the charge collection efficiency of the detectors but also promotes chemical reaction of the metal electrodes with bromine, resulting in an unstable electric field and premature failure of the device. This drawback has been crippling the TlBr semiconductor radiation detector technology over the past few decades. In this exhaustive study, this polarization phenomenon has been counteracted using innovative bias polarity switching schemes. Here the highly mobile Br− species, with an estimated electro-diffusion velocity of 10−8 cm/s, face opposing electro-migration forces during every polarity switch. This minimizes the device polarization and availability of Br− ions near the metal electrode. Our results indicate that it is possible to achieve longer device lifetimes spanning more than 17 000 h (five years of 8 × 7 operation for planar and pixelated radiation detectors using this technique. On the other hand, at constant bias, 2500 h is the longest reported lifetime with most devices less than 1000 h. After testing several biasing switching schemes, it is concluded that the critical bias switching frequency at an applied bias of 1000 V/cm is about 17 μHz. Using this groundbreaking result, it will now be possible to deploy this highly efficient room temperature semiconductor material for field applications in homeland security, medical imaging, and physics research.

  15. Catalytic properties of Thallium-containing mesoporous silicas

    Directory of Open Access Journals (Sweden)

    A. Baradji

    2017-02-01

    Full Text Available The benzylation of benzene by benzyl chloride over a series of Thallium-containing mesoporous silicas with different Tl contents has been investigated. These materials (Tl-HMS-n have been characterized by chemical analysis, N2 adsorption/desorption isotherm and X-ray diffraction (XRD. The mesoporous Thallium-containing materials showed both high activity and high selectivity for the benzylation of benzene. More interesting is the observation that these catalysts are always active and selective for large molecules like naphthenic compounds such as methoxynaphthalene.

  16. A comparison of the clinical relevance of thallium201 and ...

    African Journals Online (AJOL)

    Thallium-201 is at present the radiotracer of choice for the clinical evaluation of myocardial blood flow. Although different technetium-99m-isonitrile agents have been synthesised recently, only 99mTc-melhoxyisobutyl-isonitrile (99mTc_MIBI) has proved to hold promise for clinical implementation. The myocardial distribution ...

  17. Een bepalingsmethode voor thallium in regenwater met behulp van voltammetrie

    NARCIS (Netherlands)

    Struijs; J.; Wolfs; P.M.; Esseveld; F.G.van

    1985-01-01

    In dit rapport wordt een bepalingmethode beschreven voor thallium in het nanogram/liter-gebied, waarbij gebruik wordt gemaakt van differentiele pulse-anodic stripping voltammetry (DPASV) aan de dunne kwikfilm. Met deze techniek blijkt het mogelijk om de concentratie van dit element rechtstreeks

  18. IRIS Toxicological Review of Thallium and Compounds (External Review Draft)

    Science.gov (United States)

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certai...

  19. Band-Structure of Thallium by the LMTO Method

    DEFF Research Database (Denmark)

    Holtham, P. M.; Jan, J. P.; Skriver, Hans Lomholt

    1977-01-01

    The relativistic band structure of thallium has been calculated using the linear muffin-tin orbital (LMTO) method. The positions and extents of the bands were found to follow the Wigner-Seitz rule approximately, and the origin of the dispersion of the bands was established from the canonical s...

  20. A Simple and Rapid Complexometric Determination of Thallium(III ...

    African Journals Online (AJOL)

    A simple, rapid and selective complexometric method is proposed for the determination of thallium(III), using mercaptoethane(EtSH) as demasking agent. The sample solution containing Tl(III) is first complexed with excess EDTA and the surplus EDTA is removed by titration at pH 5–6 with zinc sulphate solution using ...

  1. L-Tyrosine immobilized on multiwalled carbon nanotubes: A new substrate for thallium separation and speciation using stabilized temperature platform furnace-electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Pablo H.; Gil, Raul A. [Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, CP 5700, San Luis (Argentina); Smichowski, Patricia, E-mail: smichows@cnea.gov.ar [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Rivadavia 1917, CP C1033 AAJ, Ciudad de Buenos Aires (Argentina); Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral. Paz 1499, B1650KNA San Martin (Argentina); Polla, Griselda [Comision Nacional de Energia Atomica, Gerencia de Investigacion y Aplicaciones, Av.Gral. Paz 1499, B1650KNA San Martin (Argentina); Martinez, Luis D., E-mail: ldm@unsl.edu.ar [Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, CP 5700, San Luis (Argentina)

    2009-12-10

    An approach for the separation and determination of inorganic thallium species is described. A new sorbent, L-tyrosine-carbon nanotubes (L-tyr-CNTs), was used and applied to the analysis of tap water samples. At pH 5.0, L-tyr was selective only towards Tl(III), while total thallium was determined directly by stabilized temperature platform furnace-electrothermal atomic absorption spectrometry (STPF-ETAAS). The Tl(III) specie, which was retained by L-tyrosine, was quantitatively eluted from the column with 10% of nitric acid. An on-line breakthrough curve was used to determine the column capacity, which resulted to be 9.00 {mu}mol of Tl(III) g{sup -1} of L-tyr-CNTs with a molar ratio of 0.14 (moles of Tl bound to moles of L-tyr at pH 5). Transient peak areas revealed that Tl stripping from the column occurred instantaneously. Effects of sample flow rate, concentration and flow rate of the eluent, and interfering ions on the recovery of the analyte were systematically investigated. The detection limit for the determination of total thallium (3{sigma}) by STPF-ETAAS was 150 ng L{sup -1}. The detection limit (3{sigma}) for Tl(III) employing the separation system was 3 ng L{sup -1}, with an enrichment factor of 40. The precision of the method expressed as the relative standard deviation (RSD) resulted to be 3.4%. The proposed method was applied to the speciation and determination of inorganic thallium in tap water samples. The found concentrations were in the range of 0.88-0.91 {mu}g L{sup -1} of Tl(III), and 3.69-3.91 {mu}g L{sup -1} of total thallium.

  2. A Simple and Rapid Complexometric Determination of Thallium(III ...

    African Journals Online (AJOL)

    NJD

    2005-10-08

    Oct 8, 2005 ... surplus EDTA is removed by titration at pH 5–6 with zinc sulphate solution using xylenol orange as indicator. ... Reproducible and accurate results are obtained in the concentration range 4–80 mg of thallium with a relative error ≤ ±0.6% .... soluble and stable 1:1 complex with Tl(I) so formed.22 This was.

  3. Thallium in the hydrosphere of south west England

    Energy Technology Data Exchange (ETDEWEB)

    Law, Sin [School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom); Turner, Andrew, E-mail: aturner@plymouth.ac.uk [School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2011-12-15

    Thallium is a highly toxic metal whose environmental concentrations, distributions and behaviour are not well understood. In the present study we measure the concentrations of Tl in filtered and unfiltered samples of rain, tap, river, estuarine and waste waters collected from south west England. Dissolved Tl was lowest (<20 ng L{sup -1}) in tap water, rain water, treated sewage and landfill effluents, estuarine waters, and rivers draining catchments of sandstones and shales. Concentrations up to about 450 ng L{sup -1} were observed in rivers whose catchments are partly mineralized and where metal mining was historically important, and the highest concentration ({approx}1400 ng L{sup -1}) was measured in water abstracted directly from an abandoned mine. Compared with other trace metals measured (e.g. As, Cd, Co, Cr, Cu, Ni, Pb, Zn), Tl has a low affinity for suspended particles and undergoes little removal by conventional (hydroxide precipitation) treatment of mine water. - Highlights: > Thallium concentrations have been measured in natural and waste waters from south west England. > Dissolved concentrations spanned three orders of magnitude and were highest in water from an abandoned mine. > Inputs associated with historical metal mine workings are the most important to the regional hydrosphere. - Concentrations of dissolved thallium in waters of south west England span two orders of magnitude and are greatest in water from an abandoned mine.

  4. [Efficiency of hemoperfusion on clearing thallium based on atomic absorption spectrometry].

    Science.gov (United States)

    Tian, Tian; Wang, Yongan; Nie, Zhiyong; Wang, Jiao; Peng, Xiaobo; Yuan, Ye; Li, Wanhua; Qiu, Zewu; Xue, Yanping; Xiong, Yiru

    2015-04-01

    To determine thallium in whole blood by atomic absorption detection method, and to investigate the eliminating effect of hemoperfusion (HP) for thallium in blood. The blood of Beagle dogs which had not exposed to thallium before were obtained for preparation of thallium nitrate ( TlNO3 )-containing solution in three concentrations according to the conversion formula based on animal weight and volume of blood. HP was performed in the simulated in vivo environment. The content of TlNO3 in blood of the next group was determined on the amount of TlNO3 for the last HP of the former dose group. Thallium quantity in different samples was measured with atomic absorption spectrometer blood samples before and after HP. Finally, the thallium concentration in blood was analyzed statistically. Thallium concentrations showed a good linear relationship in the range of 0-200 μg/L (r = 0.998 4). The intra-day precision (RSD) was lower than 4.913%, the intra-day recovery rate was 96.2%-111.9%; the inter-day precision (RSD) was lower than 7.502%, the inter-day recovery rate was 89.6%-105.2%. The concentration of thallium in blood was significantly reduced after HP per time in high, middle, and low dose groups [(453.43 ± 27.80) mg/L to (56.09 ± 14.44) mg/L in high dose group, F = 8.820, P = 0.003; (64.51 ± 13.60) mg/L to (3.19 ± 0.23) mg/L in middle dose group, F = 36.312, P = 0.000; (5.40 ± 0.98) mg/L to (0.38 ± 0.25) mg/L in low dose group, F = 46.240, P = 0.000 ]. The adsorption rate of four times of HP in high, middle and low dose group were (87.63 ± 2.48 )%, (95.06 ± 1.54 )% and (92.76 ± 4.87)%, respectively, without significant difference (F = 4.231, P = 0.070). The method for measuring thallium was established, and it shows a very stable, simple, sensitive for determination of thallium. HP can effectively remove thallium from blood. Thallium concentration can be reduced by 90% after four times of HP. HP is also effective even when thallium concentration is not high.

  5. Left ventricular dilatation and pulmonary thallium uptake after single-photon emission computer tomography using thallium-201 during adenosine-induced coronary hyperemia

    Energy Technology Data Exchange (ETDEWEB)

    Iskandrian, A.S.; Heo, J.; Nguyen, T.; Lyons, E.; Paugh, E. (Philadelphia Heart Institute, PA (USA))

    1990-10-01

    This study examined the implications of left ventricular (LV) dilatation and increased pulmonary thallium uptake during adenosine-induced coronary hyperemia. The lung-to-heart thallium ratio in the initial images was significantly higher in patients with coronary artery disease (CAD) than normal subjects; 0.48 +/- 0.16 in 3-vessel disease (n = 16), 0.43 +/- 0.10 in 2-vessel disease (n = 20), 0.43 +/- 0.08 in 1-vessel disease (n = 16) and 0.36 +/- 0.05 in normal subjects (n = 7) (p less than 0.001, 0.09 and 0.06, respectively). There was a significant correlation between the severity and the extent of the perfusion abnormality (determined from the polar maps) and the lung-to-heart thallium ratio (r = 0.51 and 0.52, respectively, p less than 0.0002). There was also a significant correlation between lung thallium washout and lung-to-heart thallium ratio (r = 0.42, p = 0.0009) and peak heart rate (r = -0.49, p less than 0.0001). The LV dilatation was mostly due to an increase in cavity dimension (30% increase) and to a lesser extent (6% increase) due to increase in LV size. (The cavity dimensions were measured from the short-axis slices at the midventricular level in the initial and delayed images). The dilation was seen in patients with CAD but not in the normal subjects. These changes correlated with the extent and severity of the thallium perfusion abnormality. Thus, adenosine-induced coronary hyperemia may cause LV dilation and increased lung thallium uptake on the basis of subendocardial ischemia.

  6. Early detection of restenosis after successful percutaneous transluminal coronary angioplasty by exercise-redistribution Thallium scintigraphy

    NARCIS (Netherlands)

    W. Wijns (William); P.W.J.C. Serruys (Patrick); J.H.C. Reiber (Johan); P.J. de Feyter (Pim); M.J.B.M. van den Brand (Marcel); M.L. Simoons (Maarten); P.G. Hugenholtz (Paul)

    1985-01-01

    textabstractThe value of exercise testing and thallium scintigraphy in predicting recurrence of angina pectoris and restenosis after a primary successful transluminal coronary angioplasty (PTCA) was prospectively evaluated. In 89 patients, a symptom-limited exercise electrocardiogram (ECG) and

  7. Oral zinc sulphate in treatment of patients with thallium poisoning: A clinical therapeutic trial

    Directory of Open Access Journals (Sweden)

    Ahmed A. Al-Mohammadi

    2011-06-01

    Full Text Available Thallium poisoning is usually associated with typical dermatological features simulating that of zinc deficiency. The aim of this study was to evaluate the role of oral zinc sulphate in the treatment of patients with thallium poisoning.Materials and methods: This clinical therapeutic trial study was conducted in Departments of Dermatology of Baghdad and Basrah Teaching Hospitals from February 2008 - February 2010, where a total of 37 patients with thallium poisoning were enrolled.A detailed history was taken from all patients and complete clinical examination was performed. All patients received zinc sulphate in a dose of 5 mg/kg three times a day few days before confirming the diagnosis of thallium poisoning. Thallium in urine had been measured using the colorimetric method and was positive in all patients. After confirming the diagnosis of thallium poisoning, thallium antidotes Prussian blue was given to 32 patients.Results: Age range of 37 patients was 5-33 (24±5.3 years. The dermatological findings were mainly: anagen hair loss affected the scalp and limbs. Also, dusky ecchymotic red dermatitis like rash was observed on the face and dorsum of hands and legs, while neurological manifestations were mainly of peripheral neuropathy, were reported in 21 (55% patients. All patients but two responded promptly to a trial of zinc sulphate within few days.Conclusion: Oral Zinc sulphate appears to be an effective and safe treatment for thallium poisoning particularly for skin and hair features and in reducing its lethal progression and complications. J Clin Exp Invest 2011;2(2:133-7

  8. Fate of Thallium(I) in Reverse Osmosis and Chlorinated Water Matrices

    Science.gov (United States)

    2014-02-01

    THALLIUM(I) IN REVERSE OSMOSIS AND CHLORINATED WATER MATRICES ECBC-TR-1127 Approved for public release; distribution is unlimited...3. DATES COVERED (From - To) Apr 2010 - Dec 2011 4. TITLE AND SUBTITLE Fate of Thallium(I) in Reverse Osmosis and Chlorinated Water Matrices... osmosis (RO) and RO water with added chlorine (RO-Cl) was measured using inductively coupled plasma optical emission spectroscopy (ICP-OES) for a period of

  9. Thallium in the hydrosphere of south west England.

    Science.gov (United States)

    Law, Sin; Turner, Andrew

    2011-12-01

    Thallium is a highly toxic metal whose environmental concentrations, distributions and behaviour are not well understood. In the present study we measure the concentrations of Tl in filtered and unfiltered samples of rain, tap, river, estuarine and waste waters collected from south west England. Dissolved Tl was lowest (<20 ng L(-1)) in tap water, rain water, treated sewage and landfill effluents, estuarine waters, and rivers draining catchments of sandstones and shales. Concentrations up to about 450 ng L(-1) were observed in rivers whose catchments are partly mineralized and where metal mining was historically important, and the highest concentration (~1400 ng L(-1)) was measured in water abstracted directly from an abandoned mine. Compared with other trace metals measured (e.g. As, Cd, Co, Cr, Cu, Ni, Pb, Zn), Tl has a low affinity for suspended particles and undergoes little removal by conventional (hydroxide precipitation) treatment of mine water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    Energy Technology Data Exchange (ETDEWEB)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.; el-Etr, A.A.; Bakhos, M.; Sullivan, H.J.; Montoya, A.; Pifarre, R.

    1986-02-01

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques.

  11. Comparison of thallium deposition with segmental perfusion in pigs with chronic hibernating myocardium.

    Science.gov (United States)

    Baldwa, Sunil; Rana, Muzamil; Canty, John M; Fallavollita, James A

    2008-12-01

    Viable, chronically dysfunctional myocardium with reduced resting flow (or hibernating myocardium) is an important prognostic factor in ischemic heart disease. Although thallium-201 imaging is frequently used to assess myocardial viability in patients with ischemic cardiomyopathy, there are limited data regarding its deposition in hibernating myocardium, and this data suggest that thallium retention may be supernormal compared with control myocardium. Accordingly, pigs (n=7) were chronically instrumented with a 1.5 mm Delrin stenosis on the proximal left anterior descending coronary artery (LAD) to produce hibernating myocardium. Four months later, severe anteroapical hypokinesis was documented with contrast ventriculography (wall motion score, 0.7+/-0.8; normal=3), and microsphere measurements confirmed reduced resting flow (LAD subendocardium, 0.78+/-0.34 vs. 0.96+/-0.24 ml.min(-1).g(-1) in remote; P<0.001). Absolute deposition of thallium-201 and insulin-stimulated [18F]-2 fluoro-2-deoxyglucose (FDG) were assessed over 1 h and compared with resting flow (n=704 samples). Thallium-201 deposition was only weakly correlated with perfusion (r2=0.20; P<0.001) and was more homogeneously distributed (relative dispersion, 0.12+/-0.03 vs. 0.29+/-0.10 for microsphere flow; P<0.01). Thus after 1 h relative thallium-201 (subendocardium LAD/remote, 0.96+/-0.16) overestimated relative perfusion (0.78+/-0.32; P<0.0001) and underestimated the relative reduction in flow. Viability was confirmed by both histology and preserved FDG uptake. We conclude that under resting conditions, thallium-201 redistribution in hibernating myocardium is nearly complete within 1 h, with similar deposition to remote myocardium despite regional differences in flow. These data suggest that in this time frame thallium-201 deposition may not discriminate hibernating myocardium from dysfunction myocardium with normal resting flow. Since hibernating myocardium has been associated with a worse prognosis

  12. Thallium uptake and biological behaviour in childhood brain tumours

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, E.J.; Howman-Giles, R.; Kellie, S.; Uren, R.F. [Royal Alexandra Hospital for Children, Sydney, NSW (Australia)

    1998-03-01

    Full text: The histopathological grade and radiological appearance of the diverse cerebral neoplasms in childhood frequently poorly reflect their biological behaviour. We examined thallium accumulation prior to treatment (and in several cases, at intervals there after) in 13 children to determine its usefulness as a tumour marker. 23 SPECT studies were acquired 20 minutes after the injection of 1-3 mCi of {sup 201}TI. Thallium index (TI), the ratio of counts in tumour/normal brain, was calculated. No uptake was seen in two patients (pts) with a Grade 1 cerebellar astrocytomas (disease free at 4/12 f/u). Three pts with medulloblastomas were studied. One pt showed intense uptake (Tl =12). His tumour (proliferative antigen stain Ki67 = 50%) recurred early after debulking surgery (Tl +ve prior to CT or MRI changes). The second pt was imaged at relapse (Ki67 = 60%) and showed intense uptake, Tl = 17. The third pt showed lower level uptake (Tl = 2), Ki67 = 5%, and is disease-free at 5/12 (as per {sup 201}TI and MRI). One pt with a Grade 1 brainstem glioma showed Tl = 5 and has progressed rapidly despite low grade histology. Four pts with chiasmatic-hypothalamic gliomas have been studied. Although these neoplasms are usually low grade histologically, their growth properties vary greatly. Two pts with Tl<2.5 have been conservatively managed because of slow tumour growth. The other two pts have Tl>3.5 and have required aggressive treatment for rapid disease progression. One pt with a large pilocytic astrocytoma of the optic chiasm showed Tl = 9.5. Active treatment was not undertaken. One pt with a pineal germ cell tumour showed avid {sup 201}TI uptake (Tl not performed) and has had two normal studies, and is clinically well, since BMT. Avid {sup 201}TI uptake also seen in one pt with cerebral neuroblastoma. (Died at 8/12 after Dx.) Thus, {sup 201}TI accumulates in histologically diverse paediatric neoplasms. The Tl appears to reflect biological behaviour in the limited

  13. Evaluation of muscular lesions in connective tissue diseases: thallium 201 muscular scans

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, G.; Guillet, J.; Sanciaume, C.; Maleville, J.; Geniaux, M.; Morin, P.

    1988-04-01

    We performed thallium 201 muscle scans to assess muscular involvement in 40 patients with different connective tissue diseases (7 with dermatomyositis, 7 with systemic lupus erythematosus, 12 with progressive systemic scleroderma, 2 with calcinosis, Raynaud's phenomenon, esophageal involvement, sclerodactyly, and telangiectasia (CREST) syndrome, 3 with monomelic scleroderma, 6 with morphea, and 3 with Raynaud's disease). Only 12 of these patients complained of fatigability and/or myalgia. Electromyography was performed and serum levels of muscle enzymes were measured in all patients. Comparison of thallium 201 exercise recording with the other tests revealed that scan sensitivity is greater than electromyographic and serum muscle enzymes levels. Thallium 201 scans showed abnormal findings in 32 patients and revealed subclinical lesions in 18 patients, while electromyography findings were abnormal in 25 of these 32 patients. Serum enzyme levels were raised in only 8 patients. Thallium 201 scanning proved to be a useful guide for modifying therapy when laboratory data were conflicting. It was useful to evaluate treatment efficacy. Because our data indicate a 100% positive predictive value, we believe that thallium 201 scanning should be advised for severe systemic connective tissue diseases with discordant test results.

  14. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro (Ryukyu Univ., Nishihara, Okinawa (Japan). School of Medicine)

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV{sub F} on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author).

  15. Advanced crystal growth techniques for thallium bromide semiconductor radiation detectors

    Science.gov (United States)

    Datta, Amlan; Becla, Piotr; Guguschev, Christo; Motakef, Shariar

    2018-02-01

    Thallium Bromide (TlBr) is a promising room-temperature radiation detector candidate with excellent charge transport properties. Currently, Travelling Molten Zone (TMZ) technique is widely used for growth of semiconductor-grade TlBr crystals. However, there are several challenges associated with this type of crystal growth process including lower yield, high thermal stress, and low crystal uniformity. To overcome these shortcomings of the current technique, several different crystal growth techniques have been implemented in this study. These include: Vertical Bridgman (VB), Physical Vapor Transport (PVT), Edge-defined Film-fed Growth (EFG), and Czochralski Growth (Cz). Techniques based on melt pulling (EFG and Cz) were demonstrated for the first time for semiconductor grade TlBr material. The viability of each process along with the associated challenges for TlBr growth has been discussed. The purity of the TlBr crystals along with its crystalline and electronic properties were analyzed and correlated with the growth techniques. Uncorrected 662 keV energy resolutions around 2% were obtained from 5 mm x 5 mm x 10 mm TlBr devices with virtual Frisch-grid configuration.

  16. Thallium distribution in sediments from the Pearl river basin, China

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Juan [Guangzhou University, Key Laboratory of Waters Safety and Protection in the Pearl River Delta, Ministry of Education, Guangzhou (China); Forschungszentrum Dresden-Rossendorf (FZD), Institute of Radiochemistry, Research Site Leipzig, Leipzig (Germany); Wang, Jin; Chen, Yongheng [Guangzhou University, Key Laboratory of Waters Safety and Protection in the Pearl River Delta, Ministry of Education, Guangzhou (China); Qi, Jianying [Department of Environmental Science and Engineering, Guangzhou University, Guangzhou (China); Lippold, Holger [Forschungszentrum Dresden-Rossendorf (FZD), Institute of Radiochemistry, Research Site Leipzig, Leipzig (Germany); Wang, Chunlin [Guangdong Provincial Academy of Environmental Science, Guangzhou (China)

    2010-10-15

    Thallium (Tl) is a rare element of high toxicity. Sediments sampled in three representative locations near industries utilizing Tl-containing raw materials from the Pearl River Basin, China were analyzed for their total Tl contents and the Tl contents in four sequentially extracted fractions (i.e., weak acid exchangeable, reducible, oxidizable, and residual fraction). The results reveal that the total Tl contents (1.25-19.1 {mu}g/g) in the studied sediments were slightly high to quite high compared with those in the Chinese background sediments. This indicates the apparent Tl contamination of the investigated sediments. However, with respect to the chemical fractions, Tl is mainly associated with the residual fraction (>60%) of the sediments, especially of those from the mining area of Tl-bearing pyrite minerals, indicating the relatively low mobility, and low bioavailability of Tl in these sediments. This obviously contrasts with the previous findings that Tl is mainly entrapped in the first three labile fractions of the contaminated samples. Possible reasons were given for the dominating association of Tl with the residual fraction (>95%) of the mining area sediments. The significant role of certain K-containing silicates or minerals of these sediments on retaining Tl in the residual fraction, discovered by this study, provides a special field of research opportunity for the Tl-containing wastewater treatment. (Copyright copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Electrochemical properties of modified copper-thallium hexacyanoferrate electrode in the presence of different univalent cations

    Energy Technology Data Exchange (ETDEWEB)

    Rutkowska, Iwona A.; Stroka, Jadwiga [Department of Chemistry, University of Warsaw, Pasteura 1, PL-02-093 Warsaw (Poland); Galus, Zbigniew [Department of Chemistry, University of Warsaw, Pasteura 1, PL-02-093 Warsaw (Poland)], E-mail: zbgalus@chem.uw.edu.pl

    2008-04-20

    The preparation of copper(II) hexacyanoferrate (CuHCF) films on the surface of gold electrodes as well as their characterization in solutions of various alkali metal and NH{sub 4}{sup +} cations and in the presence of thallium(I) are described. The electrochemical quartz crystal microbalance and cyclic voltammetric techniques were used. In 0.50 M lithium nitrate, even at submillimolar concentration of Tl(I), the formal potential of CuHCF was shifted to more positive values. At higher Tl(I) concentrations, the formal potential of the CuHCF redox reaction changed linearly with the logarithm of Tl(I) concentration (in the 0.50 M solution of lithium or another alkali metal nitrate). From such dependencies, selectivity coefficients K{sub Tl/M} were calculated, and they show that the CuHCF film on the gold electrode interacts preferentially with Tl(I). High affinity of Tl(I) to copper hexacyanoferrate, that was observed in the presence of alkali metal cations, was explained by relatively strong donor-acceptor interactions of Tl(I) ions with nitrogen in CN groups of the CuHCF film. It was also shown for simple M{sub 4}[Fe(CN){sub 6}] metal ferrocyanate salts (where M = Li{sup +}, Na{sup +}, K{sup +}, Rb{sup +}, Cs{sup +} and Tl{sup +}) that there is a preferential interaction of Tl{sup +} with CN group consistent with formation of a Tl-NC-Fe bridge.

  18. Effective removal of trace thallium from surface water by nanosized manganese dioxide enhanced quartz sand filtration.

    Science.gov (United States)

    Huangfu, Xiaoliu; Ma, Chengxue; Ma, Jun; He, Qiang; Yang, Chun; Zhou, Jian; Jiang, Jin; Wang, Yaan

    2017-12-01

    Thallium (Tl) has drawn wide concern due to its high toxicity even at extremely low concentrations, as well as its tendency for significant accumulation in the human body and other organisms. The need to develop effective strategies for trace Tl removal from drinking water is urgent. In this study, the removal of trace Tl (0.5 μg L -1 ) by conventional quartz sand filtration enhanced by nanosized manganese dioxide (nMnO 2 ) has been investigated using typical surface water obtained from northeast China. The results indicate that nMnO 2 enhanced quartz sand filtration could remove trace Tl(I) and Tl(III) efficiently through the adsorption of Tl onto nMnO 2 added to a water matrix and onto nMnO 2 attached on quartz sand surfaces. Tl(III)-HA complexes might be responsible for higher residual Tl(III) in the effluent compared to residual Tl(I). Competitive Ca 2+ cations inhibit Tl removal to a certain extent because the Ca 2+ ions will occupy the Tl adsorption site on nMnO 2 . Moreover, high concentrations of HA (10 mgTOC L -1 ), which notably complexes with and dissolves nMnO 2 (more than 78%), resulted in higher residual Tl(I) and Tl(III). Tl(III)-HA complexes might also enhance Tl(III) penetration to a certain extent. Additionally, a higher pH level could enhance the removal of trace Tl from surface water. Finally, a slight increase of residual Tl was observed after backwash, followed by the reduction of the Tl concentration in the effluent to a "steady" state again. The knowledge obtained here may provide a potential strategy for drinking water treatment plants threatened by trace Tl. Copyright © 2017. Published by Elsevier Ltd.

  19. [Graphite furnace atomic absorption spectrometry for determination of thallium in blood].

    Science.gov (United States)

    Zhang, Q L; Gao, G

    2016-04-20

    Colloidal palladium was used as chemical modifier in the determination of blood thallium by graphite furnace atomic absorption spectrometry. Blood samples were precipitated with 5% (V/V)nitric acid, and then determined by GFAAS with colloidal palladium used as a chemical modifier. 0.2% (W/V)sodium chloride was added in the standard series to improve the matrix matching between standard solution and sample. The detection limit was 0.2 μg/L. The correlation coefficient was 0.9991. The recoveries were between 93.9% to 101.5%.The relative standard deviations were between 1.8% to 2.7%.The certified reference material of whole blood thallium was determined and the result was within the reference range Conclusion: The method is accurate, simple and sensitive, and it can meet the needs of detection thallium in blood entirely.

  20. Myocardial perfusion defect on thallium-201 imaging in patients with chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Mehrotra, P.P.; Weaver, Y.J.; Higginbotham, E.A.

    1983-08-01

    Six patients with angina pectoris had reversible perfusion defects on stress and redistribution thallium imaging. Three patients had a positive electrocardiographic response to exercise. No significant coronary artery lesions were seen on coronary arteriography in any of the six patients. All had mild to moderate hypoxemia at rest and physiologic evidence of chronic obstructive pulmonary disease as defined by the decrease in the ratio of forced expiratory volume at 1 second to forced vital capacity (FEV1/FVC X 100) or decrease in the forced midexpiratory flow rate (FEF25-75), or both. None had clinical findings suggestive of any of the reported causes of positive thallium scans in patients with normal coronary arteriograms. Cellular dysfunction produced by hypoxemia affecting the uptake of thallium seems to be the most likely mechanism of this abnormality.

  1. Early and delayed thallium-201 scintigraphy in thyroid nodules: the relationship between early thallium-201 uptake and perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Derebek, E. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Biberoglu, S. [Dept. of Internal Medicine, Div. of Endocrinology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Kut, O. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yesil, S. [Dept. of Internal Medicine, Div. of Endocrinology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Saydam, S. [Dept. of Surgery, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yilmaz, M. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yenici, O. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Igci, E. [Dept. of Radiology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Gokce, O. [Dept. of Surgery, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Canda, S. [Dept. of Pathology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Bueyuekgebiz, A. [Dept. of Pediatrics, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Dogan, A.S. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Durak, H. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey)

    1996-05-01

    Seventy-six patients with tyroid nodules were studied. Initially, 75 MBq of thallium-201 was injected. The thyroid gland was imaged 15 min (early) and 3 h (delayed) after the injection. Thereafter, 185 MBq technetium-99m pertechnetate was injected. Immediately after the injection, a 1-min perfusion image was acquired, followed by an image at 20 min. Increased early and delayed {sup 201}Tl uptake compared with the contralateral thyroid tissue was adopted as the criterion for malignancy. Sensitivity, specificity and negative predictive values were found to be 85%, 64% and 78%, respectively, in operated patients, but these values were 86%, 87% and 95%, respectively, in the whole group, including patients followed with fine-needle aspiration biopsy. With the purpose of investigating the relationship between perfusion and early {sup 201}Tl uptake, bot perfusion and early images were graded comparing nodular activity with contralateral thyroid activity. There was a poor correlation between perfusion and {sup 201}Tl uptake. The correlation was even worse in hyperactive nodules. It is concluded that early and delayed {sup 201}Tl imaging should not be used in the differential diagnosis of cold nodules and that early {sup 201}Tl uptake seems to be more closely related to factors other than perfusion. (orig.)

  2. Synthesis, Characterization and Antibacterial Studies of N-(Benzothiazol-2-yl-4-chlorobenzenesulphonamide and Its Neodymium(III and Thallium(III Complexes

    Directory of Open Access Journals (Sweden)

    Lawrence Nnamdi Obasi

    2017-02-01

    Full Text Available N-(Benzothiazol-2-yl-4-chlorobenzenesulphonamide (NBTCS was synthesized by condensation reaction of 4-chlorobenzenesulphonyl chloride and 2-aminobenzothiazole in acetone under reflux. Neodymium(III and thallium(III complexes of the ligand were also synthesized. Both ligand and metal complexes were characterized using UV-Vis, IR, 1H- and 13C-NMR spectroscopies, elemental analysis and molar conductance measurement. IR studies revealed that the ligand is tridentate and coordinates to the metal ions through nitrogen and oxygen atoms of the sulphonamide group and nitrogen atom attached to benzothiazole ring. The neodymium(III complex displays a coordination number of eight while thallium(III complex displays a coordination number of six. The ligand and its complexes were screened in vitro for their antibacterial activities against Escherichia coli strains (E. coli 6 and E. coli 13, Proteus species, Staphylococcus aureus and Pseudomonas aeruginosa using the agar well diffusion technique. The synthesized compounds were found to be more active against the microorganisms screened relative to ciprofloxacin, gentamicin and co-trimoxazole.

  3. Thallium pollution in China: A geo-environmental perspective.

    Science.gov (United States)

    Xiao, Tangfu; Yang, Fei; Li, Shehong; Zheng, Baoshan; Ning, Zengping

    2012-04-01

    It is well known that thallium (Tl) is a non-essential and toxic metal to human health, but less is known about the geo-environmentally-induced Tl pollution and its associated health impacts. High concentrations of Tl that are primarily associated with the epithermal metallogenesis of sulfide minerals have the potential of producing Tl pollution in the environment, which has been recognized as an emerging pollutant in China. This paper aims to review the research progress in China on Tl pollution in terms of the source, mobility, transportation pathway, and health exposure of Tl and to address the environmental concerns on Tl pollution in a geo-environmental perspective. Tl associated with the epithermal metallogenesis of sulfide minerals has been documented to disperse readily and accumulate through the geo-environmental processes of soil enrichment, water transportation and food crop growth beyond a mineralized zone. The enrichments of Tl in local soil, water, and crops may result in Tl pollution and consequent adverse health effects, e.g. chronic Tl poisoning. Investigation of the baseline Tl in the geo-environment, proper land use and health-related environmental planning and regulation are critical to prevent the Tl pollution. Examination of the human urinary Tl concentration is a quick approach to identify exposure of Tl pollution to humans. The experiences of Tl pollution in China can provide important lessons for many other regions in the world with similar geo-environmental contexts because of the high mobility and toxicity of Tl. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Medical geology of arsenic, selenium and thallium in China.

    Science.gov (United States)

    Li, Shehong; Xiao, Tangfu; Zheng, Baoshan

    2012-04-01

    Arsenic (As), selenium (Se) and thallium (Tl) are three trace metals (metalloids) of high concern in China because deficiency or excess expose can cause a range of endemic diseases, such as endemic arsenism, selenosis, Keshan disease (KD), Kashin-Beck disease (KBD) and thallotoxicosis. These specific endemic diseases were attributable for overabundance or deficiency (mainly referring to selenium) of these three elements in the local environment as a result of natural geochemical processes and/or anthropologic activities. The geochemistry and human health impacts of these three trace elements have been intensively studied since the 1970s in China, in terms of geochemical sources, distribution, transportation, health impact pathways, and prevention/remediation measures. Endemic arsenism in China are induced from the exposures of high As in either drinking water or domestic combustion of As-rich coals. Both endemic selenium deficiency and selenosis occurred in China. The KD and KBD were related to the deficiency of Se in the low-Se geological belt with Se contents in soil less than 0.125mg/kg stretching from northeast to southwest of China. Endemic selenosis occurred in areas with high Se concentrations in soils derived from the Se-enriched black carbonaceous siliceous rocks, carbonaceous shale and slate. Endemic Tl poisoning occurred in southwestern China due to Tl contamination in local drinking water and vegetables surrounding the Tl-rich sulfide mineralized areas. Some measures have been taken to control and remedy the endemic diseases with significant effects in reducing health risk and damage of As, Se and Tl. However, the states of the endemic diseases of As, Se and Tl in China are still serious in some areas, and substantial research efforts regarding the health impacts of these elements are further required. This paper reviews the progress of medical geology of As, Se and Tl in China, and provides with some outlooks for future research directions. Copyright

  5. New quaternary thallium indium germanium selenide TlInGe2Se6: Crystal and electronic structure

    Science.gov (United States)

    Khyzhun, O. Y.; Parasyuk, O. V.; Tsisar, O. V.; Piskach, L. V.; Myronchuk, G. L.; Levytskyy, V. O.; Babizhetskyy, V. S.

    2017-10-01

    Crystal structure of a novel quaternary thallium indium germanium selenide TlInGe2Se6 was investigated by means of powder X-ray diffraction method. It was determined that the compound crystallizes in the trigonal space group R3 with the unit cell parameters a = 10.1798(2) Å, c = 9.2872(3) Å. The relationship with similar structures was discussed. The as-synthesized TlInGe2Se6 ingot was tested with X-ray photoelectron spectroscopy (XPS) and X-ray emission spectroscopy (XES). In particular, the XPS valence-band and core-level spectra were recorded for initial and Ar+ ion-bombarded surfaces of the sample under consideration. The XPS data allow for statement that the TlInGe2Se6 surface is rigid with respect to Ar+ ion-bombardment. Particularly, Ar+ ion-bombardment (3.0 keV, 5 min duration, ion current density fixed at 14 μA/cm2) did not cause substantial modifications of stoichiometry in topmost surface layers. Furthermore, comparison on a common energy scale of the XES Se Kβ2 and Ge Kβ2 bands and the XPS valence-band spectrum reveals that the principal contributions of the Se 4p and Ge 4p states occur in the upper and central portions of the valence band of TlInGe2Se6, respectively, with also their substantial contributions in other portions of the band. The bandgap energy of TlInGe2Se6 at the level of αg=103 cm-1 is equal to 2.38 eV at room temperature.

  6. New CZT cardiac cameras and myocardial perfusion imaging with thallium 201; Nouvelles cameras cardiaques a semi-conducteur cadmium -zinc- telluride (CZT) et scintigraphies myocardiques au thallium 201

    Energy Technology Data Exchange (ETDEWEB)

    Songy, B. [Service de medecine et imagerie nucleaire, centre cardiologique du Nord (CCN), 93 - Saint-Denis (France)

    2010-08-15

    Myocardial perfusion imaging is widely used for management of coronary artery disease. However, it suffers from technical limitations. New cardiac cameras using CZT detectors are now available and increase spatial (x2) and energy (x2) resolutions and photons sensitivity (x5). We describe here the General Electric Discovery NM 530c new camera and summarize the validation studies with technetium agents and with thallium 201, protocols to reduce doses, ultrafast protocols and perspectives offered with this new technology. (author)

  7. Genotoxic and mutagenic effects of the diagnostic use of thallium-201 in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Kelsey, K.T. (Harvard School of Public Health, Boston, MA (United States)); Donohoe, K.J. (Beth Israel Hospital, Boston, MA (United States). Div. of Nuclear Medicine); Baxter, Barbara; Memisoglu, Asli; Little, J.B.; Caggana, Michele; Liber, H.L. (Harvard School of Public Health, Boston, MA (United States))

    1991-07-01

    In order to investigate possible mutagenetic effects of in vivo exposure to low levels of ionizing radiation used in nuclear medicine, the authors examined hypoxanthine guanine phosphoribosyl transferase (hprt) mutant fraction (MF) and chromosome aberration (CA) frequency in 24 nuclear medicine patients before and after injection of thallium-201. The mean MF of the thallium-201-exposed cohort was 5.2{+-}4.4 x 10{sup -6} before injection exposure. No significant difference in MF was observed 24 h later. In 11 patients who were studied on a 3rd occasion, 30 days after thallium-201 exposure, there was again no significant difference in post-exposure as compared with the pre-exposure MF. The frequency of CA in peripheral blood lymphocytes was not significantly different, comparing pre- and 24h to 1 month post-radionuclide exposure . Thus, thallium-201 exposure was not associated with significant elevations in MF or CA frequency in lymphocytes of exposed individuals. (author). 40 refs.; 3 tabs.

  8. Systematics of c-axis Phonons in the Thallium- and Bismuth-Based Cuprate Superconductors

    NARCIS (Netherlands)

    Tsvetkov, A. A; Dulic, D.; Marel, D. van der; Damascelli, A.; Kaljushnaia, G. A.; Gorina, J. I.; Senturina, N. N.; Kolesnikov, N. N.; Ren, Z. F.; Wang, J. H.; Menovsky, A. A.; Palstra, T. T. M.

    2006-01-01

    Published in: Phys. Rev. B 60 (1999) 13196 Citing articles (CrossRef) citations recorded in [Science Citation Index] Abstract: We present grazing incidence reflectivity measurements in the far infrared region at temperatures above and below Tc for a series of thallium (Tl2Ba2CuO6, Tl2Ba2CaCu2O8) and

  9. Dipyridamole-thallium-201 tomography documenting improved myocardial perfusion with therapy in Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Nienaber, C.A.; Spielmann, R.P.; Hausdorf, G.

    1988-12-01

    Thallium-201 tomographic perfusion studies after pharmacologic vasodilation were performed in seven children (aged 2 years 8 months to 8 years 7 months), 3 to 20 months after the acute stage of the disease. In all patients coronary aneurysms were seen on cross-sectional echocardiograms. The scintigrams of six children showed no significant regional reduction of myocardial thallium-201 uptake. These children had remained asymptomatic in the follow-up period after the acute inflammatory stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with acute posterolateral myocardial infarction; obstruction of two coronary vessels supplying the defect zones was confirmed by contrast angiography. After 8 months of treatment a follow-up nuclear scan showed marked reduction in the size of the defect and almost complete abolishment of the ischemic reaction. Thus tomographic thallium-201 perfusion scintigraphy in conjunction with vasodilation stress is useful to assess myocardial perfusion in children with Kawasaki disease and demonstrates marked improvement in regional perfusion after adequate medical therapy.

  10. Laser-assisted decay and optical spectroscopy studies of neutron-deficient thallium isotopes

    CERN Document Server

    Van Beveren, Céline; Huyse, Mark

    The neutron-deficient thallium isotopes with one proton less than the Z = 82 shell closure, are situated in an interesting region of the nuclear chart, notorious for intruder states and shape coexistence. Shape coexistence is the remarkable phenomenon in which two or more distinct types of deformation occur at low energy in the same atomic nucleus. Shape coexistence has been studied intensively, experimentally as well as theoretically in different nuclei in the light-lead region and the isomerism in the thallium isotopes was among the first indications of this phenomenon. Different shapes, whose structure has been linked to specific proton orbitals above and below the Z = 82 shell closure, are present at low energy in the neutron-deficient odd-mass thallium nuclei. In the odd-odd nuclei, the coupling of an unpaired proton and unpaired neutron gives rise to multiplets of low-lying states from which some can be isomeric. Since thallium has one proton missing in the major proton shell, and when approaching neutr...

  11. Clinical features and applications of thallium-201. With reference to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige

    1988-12-01

    Thallium-201 is not only used widely in myocardial imaging but also has a great potential in other various nuclear medicine imaging studies. This paper presents clinical features and applications of thallium-201, focusing on clinical trials with thallium-201 at the Shinshu University School of Medicine. Thallium-201 myocardial scintigraphy offers information on (1) ventricular position and morphology, (2) hypertrophy or dilatation of the left ventricle, (3) hypertrophy or dilatation of the right ventricle, (4) site and extent of myocardial ischemia and infarct, (5) myocardial blood flow, (6) pulmonary congestion or interstitial pulmonary edema, and (7) pericardial effusion. It can be used in the following evaluation or diagnosis: (1) acute or old myocardial infarction, (2) angina pectoris, (3) treatment strategy or prognosis of ischemic heart disease, (4) treatment strategy or observation of bypass graft or drug therapy, (5) hypertrophic or dilated idiopathic cardiomyopathy, (6) myocardial lesions induced by sarcoidosis, collagen disease, and neuro-muscular disease, (7) ventricular hypertrophy and pulmonary edema, and (9) pericarditis, pericardial effusion, and systolic pericarditis associated with underlying disease. The significance of tumor, liver, bone marrow scintigraphies is also referred to. (Namekawa, K) 69 refs.

  12. Optimised thallium precipitation in a waste water treatment system of the flue gas desulphurisation; Optimierte Thalliumabscheidung einer RAA

    Energy Technology Data Exchange (ETDEWEB)

    Ritzerfeld, Guenter [RWE Power AG, Bergheim (Germany); Birngruber, Ingolf [RWE Power AG, Hamm (Germany); Muelder, Thomas [RWE Power AG, Ibbenbueren (Germany)

    2011-07-01

    When co-combusting substitute fuels in power plants, the element Thallium should be checked in the drain of the waste water treatment system of flue gas desulphurisation. In 2005 Thallium-concentrations exceeding the limit value were determined for the first time as a consequence of the modified analysis of the supervisory authority. The previous lower Thallium concentrations with graphite tube-atomic absorption spectrometry were caused by the high chloride concentration in RAA waste water. The RAA operating mode was checked and changed. Equipment-related weak spots were detected and corrected. (orig.)

  13. Comparison of Polythionates as Precursors for the Formation of Thallium Sulfide Layers

    Directory of Open Access Journals (Sweden)

    Vitalijus JANICKIS

    2011-11-01

    Full Text Available The processes of obtaining layers of thallium, sulfides, TlxSy, by the sorption-diffusion method on polyamide 6 using solutions of lower polythionates - sodium trithionate and tetrathionate, Na2S3O6, Na2S4O6, potassium pentathionate, K2S5O6, and of dodecathionic acid, H2S12O6, as precursors of sulfur are compared. The concentration of sorbed sulfur increases with increasing the duration of treatment, the concentration and temperature of precursor solution. It rather significantly also depends on the nature - sulfurity of polythionate, i. e. on the number of sulfur atoms in the polythionate anion: effectiveness of sulfurization using solutions of dodecathionic acid is significantly higher than that of lower polythionates. Thallium sulfide layers are formed on the surface of polyamide after the treatment of sulfurized polymer with Tl(I salt solution. The concentration of thallium in the layer increases with the increase of initial sulfurization duration and in case of H2S12O6 solution used - on the temperature of this process. The results of X-ray diffraction analysis confirmed the formation of thallium sulfide layers in the surface of polyamide 6. The phase composition of layer changes depending on the conditions of initial treatment in a H2S12O6 solution. Five thallium sulfide phases, two forms of TlS, Tl2S2, Tl4S3 and Tl2S5 were identified in the composition of the layers treated for different time with a solution of dodecathionic acid at the temperature of 20 °C and 30 °C and then with Tl(I salt solution by X-ray diffraction but the maxima of TlS and Tl2S5 phases predominate in the diffractograms.http://dx.doi.org/10.5755/j01.ms.17.4.774

  14. Thallium release from acid mine drainages: Speciation in river and tap water from Valdicastello mining district (northwest Tuscany).

    Science.gov (United States)

    Campanella, Beatrice; Casiot, Corinne; Onor, Massimo; Perotti, Martina; Petrini, Riccardo; Bramanti, Emilia

    2017-08-15

    In this work we present an advantageous method for the simultaneous separation and detection of Tl(I) and Tl(III) species through ion chromatography coupled with on-line inductively coupled plasma - mass spectrometry. Chromatographic separation between Tl(III) and Tl(I) was achieved in less than two minutes. The method was validated by recovery experiments on real samples, and by comparing the sum of the concentrations of individual Tl species with total thallium values obtained from continuous flow ICP-MS. The experimental procedure offers an accurate, sensitive and interference-free method for Tl speciation at trace levels in environmental samples. This allowed us to investigate the Tl speciation in acid mine drainages (AMD), surface waters and springs in a mining catchment in Valdicastello Carducci (Tuscany, Italy), where severe Tl contamination ad been evidenced previously. This study shows for the first time that Tl(III), in addition to Tl(I), is present in considerable amounts in water samples affected by acid mining outflow, raising the question of the origin of this thermodynamically unstable species. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Thermodynamic Study of Tl6SBr4 Compound and Some Regularities in Thermodynamic Properties of Thallium Chalcohalides

    Directory of Open Access Journals (Sweden)

    Dunya Mahammad Babanly

    2017-01-01

    Full Text Available The solid-phase diagram of the Tl-TlBr-S system was clarified and the fundamental thermodynamic properties of Tl6SBr4 compound were studied on the basis of electromotive force (EMF measurements of concentration cells relative to a thallium electrode. The EMF results were used to calculate the relative partial thermodynamic functions of thallium in alloys and the standard integral thermodynamic functions (-ΔfG0, -ΔfH0, and S0298 of Tl6SBr4 compound. All data regarding thermodynamic properties of thallium chalcogen-halides are generalized and comparatively analyzed. Consequently, certain regularities between thermodynamic functions of thallium chalcogen-halides and their binary constituents as well as degree of ionization (DI of chemical bonding were revealed.

  16. Comparative studies on right ventricular pressure and volume overloading by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Owada, K.; Tsukahara, Y.; Kijima, M.; Miyazaki, Y.; Ono, K. (Fukushima Medical Coll. (Japan))

    1982-03-01

    Thallium-201 myocardial scintigraphy was performed in 44 patients with various heart diseases including mitral stenosis, atrial septal defect, primary pulmonary hypertension, and left atrial myxoma. The morphological findings of right ventricular (RV) free wall on the scintigram and RV/IVS (interventricular septum) uptake ratio of the images obtained from the left anterior oblique projection were studied in the patients with RV pressure or volume overloading.

  17. Tunable frequency-stabilization of UV laser using a Hallow-Cathode Lamp of atomic thallium

    CERN Document Server

    Chen, Tzu-Ling; Shy, Jow-Tsong; Liu, Yi-Wei

    2013-01-01

    A frequency-stabilized ultraviolet laser system, locked to the thallium resonant transition of 377.5 nm, was demonstrated using a novel bichromatic spectroscopy technique for tuning the zero-crossing laser-lock point. The atomic thallium system is a promising candidate in atomic parity violation and permanent electric dipole moment experiments, and its 377.5 nm 6P1/2->7S1/2 transition is important for thallium laser cooling and trapping experiment. The pressure shift, owing to the high pressure bu?er gas of the hollow-cathode lamp, was observed using an atomic beam resonance as reference. Such a shift was corrected by adjusting the peak ratio of the two Doppler-free saturation pro?les resulted from two pumping beams with a 130 MHz frequency di?erence. The resulted frequency stability of the ultraviolet laser is ?0.5 MHz at 0.1 sec integration time. This scheme is compact and versatile for stabilizing UV laser systems, which acquire a sub-MHz stability and frequency tunability.

  18. Detection of human collateral circulation by vasodilation-thallium-201 tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nienaber, C.A.; Salge, D.; Spielmann, R.P.; Montz, R.; Bleifeld, W. (University Hospital Eppendorf, Hamburg (Germany, F.R.))

    1990-04-15

    Coronary arteriolar vasodilation may provoke redistribution of flow to collateral-dependent jeopardized myocardium. To assess the physiologic significance of collaterals, 80 consecutive post-infarction patients (age 58 +/- 8 years) underwent vasodilation-redistribution thallium-201 tomographic imaging after administration of 0.56 mg of intravenous dipyridamole/kg body weight. Circumferential profile analysis of thallium-201 uptake and redistribution in representative left ventricular tomograms provided quantitative assessment of transient and fixed defects and separation between periinfarctional and distant inducible hypoperfusion. Tomographic perfusion data were correlated to wall motion and collateral circulation between distinct anatomic perfusion territories. Patients were grouped according to presence (59%) or absence (41%) of angiographically visible collateral channels to jeopardized myocardium. In the presence of collaterals, distant reversible defects were larger than in absence of collaterals (p less than 0.05); the extent of combined periinfarctional and distant redistribution was also larger in collateralized patients (p less than 0.025), whereas the size of the persistent perfusion defect was similar in both groups. By prospective analysis the tomographic perfusion pattern of combined periinfarctional and distant redistribution revealed a sensitivity of 85% and a specificity of 78% for the detection of significant collateral circulation in this group of patients. Thus, using the exhausted flow reserve as a diagnostic tool, vasodilation-thallium-201 tomography has the potential to identify and quantitate collateralized myocardium in post-infarction patients and may guide diagnostic and therapeutic decision-making.

  19. [Characterization of kale (Brassica oberacea var acephala) under thallium stress by in situ attenuated total reflection FTIR].

    Science.gov (United States)

    Yao, Yan; Zhang, Ping; Wang, Zhen-Chun; Chen, Yong-Heng

    2009-01-01

    The experiment was designed based on consumption of carbon dioxide through the photosynthesis of Brassica oberacea var acephala leaf, and the photosynthesis of kale leaf under thallium stress was investigated by in situ attenuated total reflection FTIR (in situ ATR-FTIR). The ATR-FTIR showed that the absorption peaks of leaves had no obvious difference between plants growing in thallium stress soil and plants growing in non-thallium pollution soil, and the strong peaks at 3,380 cm(-1) could be assigned to the absorption of water, carbohydrate, protein or amide; the strong peaks at 2,916 and 2,850 cm(-1) assigned to the absorption of carbohydrate or aliphatic compound; the peaks at 1,640 cm(-1) assigned to the absorption of water. However, as detected by the in situ ATR-FTIR, the double peaks (negative peaks) at 2,360 and 2,340 cm(-1) that are assigned to the absorption of CO2 appeared and became high gradually. It was showed that kale was carrying photosynthesis. At the same time, the carbon dioxide consumption speed of leaf under thallium stress was obviously larger than that of the blank It was expressed that photosynthesis under thallium stress was stronger than the blank All these represented that kale had certain tolerance to the heavy metal thallium. Meanwhile, the carbon dioxide consumption of grown-up leaf was more than that of young leaf whether or not under thallium stress. It was also indicated that the intensity of photosynthesis in grown-up leaf is higher than that in young leaf.

  20. Indium Single-Ion Frequency Standard

    Science.gov (United States)

    Nagourney, Warren

    2001-01-01

    A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

  1. Diagnostic value of 123I-phenylpentadecanoic acid (IPPA) metabolic and thallium 201 perfusion imaging in stable coronary artery disease.

    Science.gov (United States)

    Walamies, M; Turjanmaa, V; Koskinen, M; Uusitalo, A

    1993-08-01

    The diagnostic value of 123I-phenylpentadecanoic acid (IPPA) metabolic cardiac imaging was studied in a group (n = 29) of patients with angiographically confirmed CAD using single photon emission computed tomography (SPECT). A symptom-limited exercise test was first done with IPPA, and 2 days later with thallium. Medications were not withheld during testing. Fourteen healthy control subjects participated in parallel IPPA and 15 in thallium tests. Data acquisition and output were comparable in the two imaging modalities. By testing various relatively simple criteria for abnormality we found that the semiquantitative interpretation was more accurate than the visual readings. The best compromise of accuracy with the scored criteria consisted of a sensitivity of 86% and a specificity of 86%, obtained with IPPA polar tomograms (mild exercise defect) and a sensitivity of 86% and a specificity of 80% obtained with thallium (regionally decreased washout). With visual interpretation alone, a sensitivity of 83% and a specificity of 71% was detected with IPPA (mild exercise defect) and 72% and 73%, respectively, with thallium (partial reversibility). The sensitivity of the exercise ECG alone was 62%. The results of this study imply that IPPA imaging could be a rational, uncomplicated clinical method for non-invasive diagnosis of CAD. The diagnostic ability of IPPA is at least as good as that of thallium, and it is possible to use them in succession.

  2. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging: A new marker of triple-vessel disease

    Energy Technology Data Exchange (ETDEWEB)

    Takeishi, Y.; Tono-oka, I.; Ikeda, K.; Komatani, A.; Tsuiki, K.; Yasui, S. (Yamagata Univ. School of Medicine (Japan))

    1991-02-01

    To investigate the significance and mechanism of dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging, we performed both dipyridamole thallium-201 imaging and dipyridamole radionuclide angiography on 83 patients with known angiograms. The dipyridamole/delayed ratio of the left ventricular dimension from the thallium-201 image was defined as the left ventricular dilatation ratio (LVDR). An LVDR greater than the mean + two standard deviations in patients without coronary artery disease was defined as abnormal. Twenty-two of 83 patients showed an abnormal LVDR, and 18 of the 22 patients (82%) had triple-vessel disease. By defect and washout analysis, the sensitivity and specificity for correctly identifying the patients as having triple-vessel disease was 72% and 76%, respectively, whereas LVDR had a sensitivity of 72% and a specificity of 93%. When LVDR was used in combination with the defect and washout criteria, sensitivity increased to 84% without a loss of specificity. In those 22 patients with abnormal LVDRs, end-diastolic volume measured by radionuclide angiography did not change after dipyridamole infusion. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging reflected relative subendocardial hypoperfusion induced by dipyridamole rather than actual chamber enlargement. The LVDR was moderately sensitive and highly specific for triple-vessel disease and provided complementary information to dipyridamole thallium-201 imaging.

  3. A preliminary investigation and evaluation of the thallium environmental impacts of the unmined Xiangquan thallium-only deposit in Hexian, China

    Science.gov (United States)

    Zhou, Taofa; Fan, Yu; Yuan, Feng; Cooke, David; Zhang, Xin; Li, Liangjun

    2008-03-01

    The Xiangquan Thallium-only deposit in Hexian, east China is a newly found near-surface and unmined shallow-seated thallium deposit. The 250t Tl deposit is hosted in Lower Ordovician Lunshan Group as lenticular and confined by northeast F1, F2 faults. The metallic minerals are dominated by pyrite, more than 95% Tl occurs in pyrite as tiny individual grains or as ‘‘invisible thallium”. Tl and other trace elements pollution in ecosystems such as soils, surface and ground waters and water sediments, plants and crops, and animal and human beings in Xiangquan near the Tl ore deposit have been investigated and evaluated. Results show that Tl as well as As and Sb in ecosystems in Xiangquan around the deposit have enriched, they came from Tl-pyrite in the ore bodies and in the parent rocks of weathered soils on top of the ore bodies and went into the nearby ecosystems through weathering, leaching and dissolving. In 2 km2 around the Xiaolongwang Mountain where the Tl ore deposit seated, soils, vegetables, crops have been polluted or heavily polluted by Tl, As and Sb. Farmlands near the ore body are not fit to grow vegetables and crops. Thermal Spring water in Xiangquan town and pond water close to the Tl deposit are not potable. Tl also enriches in human hair and urinate of villagers who live close to the Tl deposit. Even through the Tl-only deposit has put clear environmental impacts on the local environment and ecosystems around it, no serious consequences of Tl pollution have so far taken place due to unmining of the Tl deposit as well as the screen effect of the silicficious breccia cap on top of it. All this work adds new knowledge to understand Tl behavior in unmined Tl deposit, and also benefit to the local environmental protection and the future mineral resources exploration.

  4. {sup 201}Thallium SPECT, accuracy in astrocytoma diagnosis and treatment evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kaellen, K

    1999-10-01

    The aims of the studies included in this thesis were: - to investigate the reliability of {sup 201}Thallium single photon emission computed tomography. Tl SPECT for preoperative diagnosis and histological staging of malignant astrocytomas in comparison with CT; - to develop a method for quantification of cerebral thallium uptake, and to evaluate the quantitative measurement in comparison with CT, for astrocytoma treatment follow-up purposes; - to compare quantitative Tl SPECT and proton magnetic resonance spectroscopy (H-MRS) with conventional MR imagingfor astrocytoma monitoring, and to evaluate associations between change of morphological tumour characteristics during treatment and changes of cerebral thallium uptake and metabolic ratios. Results and conclusions: - High TI-index, calculated as a ratio comparing tumour uptake to uptake in the contralateral hemisphere, is an indicator of highly malignant astrocytoma. Differentiation between the high-grade astrocytomas, the low-grade astrocytomas, and infectious lesions is only partial, with an overlap of Tl-indexes between these groups. High-grade astrocytomas that do not show contrast enhancement on CT, and astrocytomas with central necrosis and moderate ring-enhancement, tend to be underestimated when evaluated by Tl-index calculation. Tl SPECT is not a reliable method for non-invasive tumour staging among the group of highly malignant astrocytomas. - Quantification of cerebral TI-uptake, defining the volume of viable tumour tissue, is a new method for astrocytoma chemotherapy monitoring. Results suggest that the method provides prognostic information, and information of treatment efficacy, at an earlier stage than CT. - We did not find a higher accuracy of quantitative Tl SPECT than of MR for monitoring purposes and our results indicated that treatment induced MR changes were interrelated with TI-uptake variations. - Multi-voxel H-MRS was difficult to apply for astrocytoma treatment monitoring, due to the

  5. Oxidative stress and DNA damage in broad bean (Vicia faba L.) seedlings induced by thallium.

    Science.gov (United States)

    Radić, Sandra; Cvjetko, Petra; Glavas, Katarina; Roje, Vibor; Pevalek-Kozlina, Branka; Pavlica, Mirjana

    2009-01-01

    Thallium (Tl) is a metal of great toxicological concern because it is highly toxic to all living organisms through mechanisms that are yet poorly understood. Since Tl is accumulated by important crops, the present study aimed to analyze the biological effects induced by bioaccumulation of Tl in broad bean (Vicia faba L.) as well as the plant's antioxidative defense mechanisms usually activated by heavy metals. Thallium toxicity was related to production of reactive oxygen species in leaves and roots of broad bean seedlings following short-term (72 h) exposure to thallium (I) acetate (0, 0.5, 1, 5, and 10 mg/L) by evaluating DNA damage and oxidative stress parameters as well as antioxidative response. The possible antagonistic effect of potassium (K) was tested by combined treatment with 5 mg/L of Tl (Tl+) and 10 mg/L of potassium (K+) acetate. Accumulation of Tl+ in roots was 50 to 250 times higher than in broad bean shoots and was accompanied by increase in dry weight and proline. Despite responsive antioxidative defense (increased activities of superoxide dismutase, ascorbate peroxidase, and pyrogallol peroxidase), Tl+ caused oxidative damage to lipids and proteins as evaluated by malondialdehyde and carbonyl group levels, and induced DNA strand breaks. Combined treatment caused no oxidative alternations to lipids and proteins though it induced DNA damage. The difference in Tl-induced genotoxicity following both acellular and cellular exposure implies indirect DNA damage. Results obtained indicate that oxidative stress is involved in the mechanism of Tl toxicity and that the tolerance of broad bean to Tl is achieved, at least in part, through the increased activity of antioxidant enzymes.

  6. Thallium Intoxication Treated with Long-Term Hemodialysis, Forced Diuresis and Prussian Blue

    DEFF Research Database (Denmark)

    Larsen, Elfinn; Solgaard, Per Bent; Freund, L. Gade

    1978-01-01

    A 56 yr old woman, who ingested 2 g of thallium sulfate, was successfully treated with long-term hemodialysis for 200 h during 10 days, combined with forced diuresis and Prussian blue. The effect of the artificial kidney dialysis was determined by repeated analysis of the Tl concentration...... in the dialysis bath and in blood samples. During the 1st 120 h of hemodialysis, 143 mg of Tl was eliminated via the artificial kidney and 110 mg via the urinary tract. The present case of acute Tl intoxication is the 1st in which long-term hemodialysis has been used in the acute phase...

  7. Experimental excitation functions of deuteron induced reactions on natural thallium up to 50 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Adam Rebeles, R., E-mail: radamreb@vub.ac.be [Cyclotron Laboratory, Vrije Universiteit Brussel, B-1090 Brussels (Belgium); Van den Winkel, P.; Hermanne, A. [Cyclotron Laboratory, Vrije Universiteit Brussel, B-1090 Brussels (Belgium); Tarkanyi, F.; Takacs, S. [Institute of Nuclear Research of the Hungarian Academy of Sciences, Debrecen H-4026 (Hungary)

    2012-10-01

    Excitation functions of deuteron induced reactions on natural thallium leading to the formation of {sup 204m,203m2+m1+g,202m,201m+g,200}Pb and {sup 202,201m+g,200m+g}Tl isotopes were determined up to 50 MeV. The cross sections were measured by an activation technique using stacked foil irradiation. The excitation functions of the investigated reactions are compared with data reported in literature and also with the theoretical results of TALYS nuclear reaction code. From the measured cross section data, the thick target yield for the medical interesting {sup 203}Pb isotope is calculated.

  8. Application of Hyphenated Techniques in Speciation Analysis of Arsenic, Antimony, and Thallium

    Science.gov (United States)

    Michalski, Rajmund; Szopa, Sebastian; Jabłońska, Magdalena; Łyko, Aleksandra

    2012-01-01

    Due to the fact that metals and metalloids have a strong impact on the environment, the methods of their determination and speciation have received special attention in recent years. Arsenic, antimony, and thallium are important examples of such toxic elements. Their speciation is especially important in the environmental and biomedical fields because of their toxicity, bioavailability, and reactivity. Recently, speciation analytics has been playing a unique role in the studies of biogeochemical cycles of chemical compounds, determination of toxicity and ecotoxicity of selected elements, quality control of food products, control of medicines and pharmaceutical products, technological process control, research on the impact of technological installation on the environment, examination of occupational exposure, and clinical analysis. Conventional methods are usually labor intensive, time consuming, and susceptible to interferences. The hyphenated techniques, in which separation method is coupled with multidimensional detectors, have become useful alternatives. The main advantages of those techniques consist in extremely low detection and quantification limits, insignificant interference, influence as well as high precision and repeatability of the determinations. In view of their importance, the present work overviews and discusses different hyphenated techniques used for arsenic, antimony, and thallium species analysis, in different clinical, environmental and food matrices. PMID:22654649

  9. Evaluation of myocardial abnormalities in collagen diseases by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru; Kagoshima, Tadashi; Sugihara, Kiyotaka (Nara Medical Univ., Kashihara (Japan)) (and others)

    1993-12-01

    This study was performed to evaluate myocardial abnormalities in patients with collagen diseases by exercise and rest thallium-201 myocardial scintigrams. A total of 65 patients without ischemic ECG changes, consisting of 18 with systemic lupus erythematosus (SLE), 18 with polymyositis (PM), 8 with progressive systemic sclerosis (PSS), and 21 with Sjoegren's syndrome (SjS), was enrolled in this study. Reversible exercise-induced defects scintigraphically suggesting myocardial ischemia were noted in 8 cases of SLE, 4 cases of PM, 4 cases of PSS, and 3 cases of SjS. Nineteen patients had exercise-induced defects and underwent cardiac catheterization, 8 of whom had normal coronary angiograms. Fixed hypoperfusion areas were observed in one case of SLE, 6 cases of PM and 3 cases of SjS. Rest thallium-201 myocardial scintigram disclosed hypoperfusion areas which were not induced by exercise in 2 cases of SLE, 3 cases of PM, one case of PSS and 5 cases of SjS. Echocardiogram showed no significant differences in ejection fraction and % fractional shortening between the disease groups and healthy control group. These findings suggest that patients with collagen diseases have abnormalities of coronary circulation at the level of the intramural vasculature before cardiac function impairment, myocardial fibrosis and functional abnormalities at the cell membrane. (author).

  10. Follow-up Thallium-201 scintigraphy after mantle field radiotherapy for Hodgkin's disease

    Energy Technology Data Exchange (ETDEWEB)

    Pierga, J.Y.; Girinski, T.; Henry-Amar, M. (Institut Gustave Roussy, Villejuif (France)); Maunoury, C.; Valette, H.; Tchernia, G.; Desgrez, A. (Centre Hospitalier de Bicetre, Le Kremlin-Bicetre (France)); Socie, G. (Institut Gustave Roussy, Villejuif (France) Hopital St Louis, Paris (France)); Cosset, J.M. (Institut Gustave Roussy, Villejuif (France) Institut Curie, Paris (France))

    1993-04-02

    Assessment of the long-term cardiac effects of mediastinal radiotherapy for Hodgkin's disease, by Thallium scintigraphy. 32 patients (14 males and 18 females) who underwent mantle field radiotherapy for Hodgkin's disease were included in this study. Twenty patients received 4 fractions of 2.5 Gy per week and 12, five fraction of 2 Gy per week, delivered on alternate days. All the patients, except three, performed exercise testing electrocardiogram and Thallium-201 tomoscintigraphy. The average time interval from completion of treatment to the study was 7 years (range 3--13 years). No patients had clinical symptoms of cardiac disease. Mean age at the time of the study was 35 years (range 23--48 years). Two electrocardiograms revealed left bundle branch block and the patients were excluded from the study. Only one out of 27 exercise electrocardiograms was abnormal in a patient with mitral valve prolapse, who was also excluded from the study. Twenty-six scintigraphies were evaluable. Twenty-two (85%) were clearly abnormal with partial or complete redistribution on delayed images. The anterior region was affected in 19 of these cases (86%). Four explorations were undoubtedly normal. Coronary angiography was not performed for ethical reasons in these asymptomatic patients. Despite possible false positive tests, the high rate of abnormality (85%) in this small series is striking. These preliminary data justify larger studies and a close long-term follow-up of these patients. 24 refs., 1 fig., 2 tabs.

  11. Thallium occurrence and partitioning in soils and sediments affected by mining activities in Madrid province (Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Gonzalez, M.A.; Garcia-Guinea, J. [National Museum of Natural Sciences, CSIC, Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Laborda, F. [Group of Analytical Spectroscopy and Sensors Group, Institute of Environmental Sciences, University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza (Spain); Garrido, F., E-mail: fernando.garrido@mncn.csic.es [National Museum of Natural Sciences, CSIC, Jose Gutierrez Abascal 2, 28006 Madrid (Spain)

    2015-12-01

    Thallium (Tl) and its compounds are toxic to biota even at low concentrations but little is known about Tl concentration and speciation in soils. An understanding of the source, mobility, and dispersion of Tl is necessary to evaluate the environmental impact of Tl pollution cases. In this paper, we examine the Tl source and dispersion in two areas affected by abandoned mine facilities whose residues remain dumped on-site affecting to soils and sediments of natural water courses near Madrid city (Spain). Total Tl contents and partitioning in soil solid phases as determined by means of a sequential extraction procedure were also examined in soils along the riverbeds of an ephemeral and a permanent streams collecting water runoff and drainage from the mines wastes. Lastly, electronic microscopy and cathodoluminescence probe are used as a suitable technique for Tl elemental detection on thallium-bearing phases. Tl was found mainly bound to quartz and alumino-phyllosilicates in both rocks and examined soils. Besides, Tl was also frequently found associated to organic particles and diatom frustules in all samples from both mine scenarios. These biogenic silicates may regulate the transfer of Tl into the soil-water system. - Highlights: • Abandoned mine residues are Tl sources in soils of Madrid catchment area. • Tl was associated to quartz and aluminosilicates in both rocks and soils. • Tl was frequently found associated to organic particles and diatom frustules. • Cathodoluminescence is a suitable technique for Tl detection on soils and rocks.

  12. The learning machine in quantitative chemical analysis : Part I. Anodic Stripping Voltammetry of Cadmium, Lead and Thallium

    NARCIS (Netherlands)

    Bos, M.; Jasink, G.

    1978-01-01

    The linear learning machine method was applied to the determination of cadmium, lead and thallium down to 10-8 M by anodic stripping voltammetry at a hanging mercury drop electrode. With a total of three trained multicategory classifiers, concentrations of Cd, Pb and Tl could be predicted with an

  13. Thallium chloride 201Tl combined with single photon emission computed tomography (SPECT) in the evaluation of vestibular schwannoma growth

    DEFF Research Database (Denmark)

    Charabi, Samih Ahmed; Lassen, N A; Thomsen, J

    1997-01-01

    Thallium chloride 201Tl combined with SPECT was performed in a series of 29 patients with neuroradiological evidence of vestibular schwannoma (VS). The relative tumor uptake (U) and relative tumor concentration (C) of the radiotracer 201Tl was determined, and the cerebellum served as a reference...

  14. Luminescence characteristics of Tl + ions co-doped RbCl:Eu 2+ crystals

    Science.gov (United States)

    Nagarajan, S.; Sudarkodi, R.

    2008-08-01

    RbCl:Eu 2+ single crystals which are co-doped with thallium display characteristic Eu 2+ emission around 420 nm and additional emission band at 312 nm with a weak shoulder around 390 nm attributable to centers involving Tl + ions. Additional excitation and emission bands observed in Tl + doped RbCl:Eu 2+ single crystals are attributed to the presence of Eu 2+ aggregates and complex centres involving both Eu 2+ and Tl + ions. Inclusion of Tl + ions in RbCl:Eu 2+ crystals is found to enhance the intensity of Eu 2+ emission at 420 nm due to an energy transfer from Tl + → Eu 2+ ions.

  15. Preparation, Characterization, and In Vivo Pharmacoscintigraphy Evaluation of an Intestinal Release Delivery System of Prussian Blue for Decorporation of Cesium and Thallium

    Directory of Open Access Journals (Sweden)

    Nidhi Sandal

    2017-01-01

    Full Text Available Background. Prussian blue (PB, ferric hexacyanoferrate is approved by US-FDA for internal decorporation of Cesium-137 (137Cs and Thallium-201 (201Tl. Aim. Since PB is a costly drug, pH-dependent oral delivery system of PB was developed using calcium alginate matrix system. Methods. Alginate (Alg beads containing PB were optimized by gelation of sodium alginate with calcium ions and effect of varying polymer concentration on encapsulation efficiency and release profile was investigated. Scanning electron microscopy (SEM was carried out to study surface morphology. Adsorption efficacy of Alg-PB beads for 201Tl was evaluated and compared with native PB. In vivo pH-dependent release of the formulation was studied in humans using gamma scintigraphy. Results. Encapsulation efficiencies of Alg-PB beads with 0.5, 1.0, 1.5, and 2.0% polymer solution were 99.9, 91, 92, and 93%, respectively. SEM and particle size analysis revealed differences between formulations in their appearance and size distribution. No drug release was seen in acidic media (pH of 1-2 while complete release was observed at pH of 6.8. Dissolution data was fitted to various mathematical models and beads were found to follow Hixson-Crowell mechanism of release. The pH-dependent release of beads was confirmed in vivo by pharmacoscintigraphy in humans.

  16. Bis(2-mercapto-1-R-imidazolyl)hydroborato complexes of aluminium, gallium, indium and thallium: compounds possessing gallium-gallium bonds and a trivalent thallium alkyl.

    Science.gov (United States)

    Yurkerwich, Kevin; Coleman, Fergal; Parkin, Gerard

    2010-08-14

    The reactions of bis(mercaptoimidazolyl)hydroborato derivatives [Bm(R)]M' (R = Me, Bu(t); M' = Li, Na, Tl) with MX(3) trihalides of aluminium, gallium and indium yield both 1:1 and 2:1 complexes of the types [Bm(R)]MX(2) and [Bm(R)](2)MX, respectively. Structurally characterized examples of the [Bm(R)]MX(2) series include [Bm(Me)]AlCl(2), [Bm(Me)]GaI(2), [Bm(Me)]InI(2), [Bm(Bu(t))]AlCl(2) and [Bm(Bu(t))]GaX(2) (X = Cl, Br, I), while structurally characterized examples of the [Bm(R)](2)MX series include [Bm(Bu(t))](2)InX (X = Cl, Br, I). In addition to the halide complexes, the trivalent dimethyl thallium complex [Bm(Bu(t))]TlMe(2) has been synthesized via the reaction of [Bm(Bu(t))]Tl with Me(2)TlCl. The reactions of [Bm(R)]M' with the monovalent halides, "GaI", InCl and InI, result in disproportionation. In the case of indium, the mononuclear complexes [Bm(Bu(t))](2)InI and [Bm(Bu(t))]InCl(kappa(2)-mim(Bu(t))) are obtained, whereas for gallium, dinuclear compounds that feature Ga-Ga bonds, namely [Bm(R)](GaI)(GaI)[Bm(R)] (R = Me, Bu(t)) have been isolated.

  17. Thallium stress testing does not predict cardiovascular risk in diabetic patients with end-stage renal disease undergoing cadaveric renal transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Holley, J.L.; Fenton, R.A.; Arthur, R.S. (Univ. of Pittsburgh, PA (USA))

    1991-05-01

    This study assessed the usefulness of thallium stress testing as a predictor of perioperative cardiovascular risk in diabetic patients with end-stage renal disease undergoing cadaveric renal transplantation. Demographic factors influencing the exercise performance in these patients were also examined. The medical records of 189 consecutive patients with diabetic nephropathy who were evaluated for cadaveric renal transplantation were reviewed. Thallium stress testing was the initial examination of cardiovascular status in 141 patients. An adequate examination was one in which at least 70% of maximum heart rate was achieved. A thallium stress test was normal if there were no ST segment depressions on the electrocardiogram and no perfusion abnormalities on the thallium scan. Forty-four patients underwent cardiac catheterization as the initial evaluation (Group C) and four patients underwent transplantation without a formal cardiovascular evaluation (Group D). Sixty-four of the 141 patients undergoing thallium stress testing had an adequate and normal examination (Group A). The incidence of perioperative cardiac events in this group was 2%. Seventy-seven patients (Group B) had an abnormal (n = 41) or an inadequate (n = 36) thallium stress test and most (n = 61) then underwent coronary angiography. The use of beta-blockers was the only predictor of an abnormal or inadequate thallium stress test. Forty-three percent of patients with inadequate or abnormal thallium stress tests had significant coronary artery disease on cardiac catheterization. The perioperative risk of cardiac events was not different in Group A versus Groups B, C, and D combined. Survival of Group A and B patients was not different but was significantly longer than that of Group C patients.

  18. Evaluation of thallium-201 scanning for detection of latent coronary artery disease

    Science.gov (United States)

    Johnson, P. C.; Leblanc, A.; Deboer, L.; Jhingran, S.

    1978-01-01

    The use of thallium imaging as a noninvasive method to accurately screen shuttle passengers for latent coronary artery disease was investigated. All radionuclide procedures were performed using an Anger type camera with a high resolution collimator. A minimum of 200,000 counts were collected for each image using a 20% window centered on the 69-83 keV X-rays. For the images obtained following injection with the patient at rest, the testing was begun 10 minutes after injection. Injections of TT during exercise were made at a point near the termination of the treadmill procedure as determined by either the appearance of ST segment changes on the electrocardiogram consistant with subendocardial ischemia, the appearance of angina-like chest pain in the patient or fatigue in the patient which required cessation of the test. The severity of heart disease was based on the medical history, physical exam, exercise electrocardiograms, chest X-rays and the coronary arteriogram.

  19. Thallium Analysis in Environmental Samples by Inductively Coupled Plasma Mass Spectrometry; Analisis de Talio en Muestras Ambientales por Espectrometria de Masas con Fuente de Plasma de Acoplamiento Inductivo

    Energy Technology Data Exchange (ETDEWEB)

    Higueras, I.; Fernandez, M.; Conde, E.; Gajate, A.

    2008-08-06

    Due to its high toxicity, thallium has been considered by the US Environmental Protection Agency as one of the priority pollutants to be controlled. While being a highly toxic element, thallium has been studied to a much lesser degree than other toxic elements, mainly because thallium is often undetected by classical analytical methods. Thallium is a rare and dispersed element that occurs mainly in sulfur-containing ores. Thus, it is a potential pollutant to surrounding environment, if Tl-rich mineral and/or their industrial wastes are not properly disposed. In this work an Inductively Coupled Plasma Mass Spectrometry analytical procedure has been developed in order to determine thallium in environmental solid samples and its application to the study of this element as a potential pollutant associated with natural and anthropogenic activities. The analytical procedure has been validated by the use of appropriate reference materials, and through the isotope dilution technique as a primary method of measurement. Finally, the developed procedure has been applied to several samples from a mining area, as one of the scenarios where thallium it is likely to occur. (Author) 87 refs.

  20. A Case-Control Study of Prenatal Thallium Exposure and Low Birth Weight in China.

    Science.gov (United States)

    Xia, Wei; Du, Xiaofu; Zheng, Tongzhang; Zhang, Bin; Li, Yuanyuan; Bassig, Bryan A; Zhou, Aifen; Wang, Youjie; Xiong, Chao; Li, Zhengkuan; Yao, Yuanxiang; Hu, Jie; Zhou, Yanqiu; Liu, Juan; Xue, Weiyan; Ma, Yue; Pan, Xinyun; Peng, Yang; Xu, Shunqing

    2016-01-01

    Thallium (Tl) is a highly toxic heavy metal widely present in the environment. Case reports have suggested that maternal exposure to high levels of Tl during pregnancy is associated with low birth weight (LBW), but epidemiological data are limited. This study was designed to evaluate whether prenatal Tl exposure is associated with an increased risk of LBW. This case-control study involving 816 study participants (204 LBW cases and 612 matched controls) was conducted in Hubei Province, China, in 2012-2014. Tl concentrations were measured in maternal urine collected at delivery, and associations with LBW were evaluated using conditional logistic regression. Higher maternal urinary Tl levels were significantly associated with increased risk of LBW [crude odds ratio (OR) = 1.52; 95% CI: 1.00, 2.30 for the highest vs. lowest tertile], and the association was similarly elevated after adjustment for potential confounders (adjusted OR = 1.90; 95% CI: 1.01, 3.58 for the highest vs. lowest tertile). Stratified analyses showed slightly higher risk estimates for LBW associated with higher Tl levels for mothers case-control study to investigate the association between prenatal Tl exposure and LBW. The results suggest that prenatal exposure to high levels of Tl may be associated with an increased risk of LBW. Xia W, Du X, Zheng T, Zhang B, Li Y, Bassig BA, Zhou A, Wang Y, Xiong C, Li Z, Yao Y, Hu J, Zhou Y, Liu J, Xue W, Ma Y, Pan X, Peng Y, Xu S. 2016. A case-control study of prenatal thallium exposure and low birth weight in China. Environ Health Perspect 124:164-169; http://dx.doi.org/10.1289/ehp.1409202.

  1. Evaluation of myocardial abnormalities in patients with collagen diseases by thallium-201 myocardial scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru (Nara Medical Univ., Kashihara (Japan))

    1992-08-01

    This study was performed to evaluate myocardial lesions in patients with collagen diseases by rest and exercise thallium-201 myocardial scintigraphies. A total of 76 patients without ischemic ECG changes, consisting of 27 cases of systemic lupus erythematosus (SLE), 17 cases of polymyositis or dermatomyositis (PM[center dot]DM), 11 cases of progressive systemic sclerosis (PSS), and 21 cases of Sjoegren's syndrome (SjS), were enrolled in this study. Reversible exercise-induced defects suggesting myocardial ischemia were noted in 12 cases of SLE, 5 cases of PM[center dot]DM, 3 cases of PSS, and 3 cases of SjS. Of the 23 patients who had exercise-induced defects, 9 patients showed normal coronary angiograms by cardiac catheterization. Fixed hypoperfusion areas were observed in 5 cases of SLE, 6 cases of PM[center dot]DM, 4 cases of PSS and 3 cases of SjS. Rest thallium-201 myocardial scintigraphy disclosed hypoperfusion areas, which were not induced by exercise, in 1 case of SLE, 4 cases of PM[center dot]DM, 1 case of PSS and 5 cases of SjS. Endomyocardial biopsy was performed on 20 patients. Myocardial lesions in PM[center dot]DM and PSS were more severe and wide spread than in SLE. Ejection fraction and fractional shortening evaluated by echocardiography had no significant differences between each disease group and the healthy control group. These findings suggest that patients with collagen diseases show the presence of abnormalities of coronary circulation at the level of the intramyocardial vasculature in the stage before impairment of cardiac function, myocardial fibrosis and functional abnormalities of the cell membrane level that were not dependent on myocardial ischemia. (author).

  2. Development and Applications of Thallium isotopes: a new proxy tracking the extent of manganese oxide burial

    Science.gov (United States)

    Owens, J. D.; Nielsen, S.; Ostrander, C.; Peterson, L. C.; Anbar, A. D.

    2015-12-01

    Thallium (Tl) isotopes are a new and potential powerful paleoredox proxy with the possibility to track bottom water oxygen conditions based on the burial flux of manganese oxides. Thallium has a residence time of ~20 thousand years, which is long enough to render modern oxic seawater conservative with respect to concentration and isotopes. The isotopic signature of Tl in the global ocean is driven mainly by two outputs (1) adsorption onto manganese oxides and (2) low temperature oceanic crust alteration. Importantly, the isotopic inputs of Tl are all nearly the same value; thus, the isotopic composition and flux of the outputs almost exclusively set the seawater signature. For relatively short term redox events it is reasonable to assume that the dominant isotope fractionation process is associated with manganese oxide precipitation because low temperature alteration is controlled by long-term average ocean crust production rates. We present a broad range of modern samples that span several open ocean profiles combined with water column and sediment profiles from the permanently anoxic basins of the Black Sea and Cariaco Basins. The open ocean shows no variation in depth profiles that encompass most of the major water masses in the Atlantic and Southern Oceans. The anoxic basins, however, reveal Tl isotope signatures closer to their inputs, which is likely due to basinal restriction. The authigenic fraction of organic-rich sediments from the Black Sea and Cariaco Basin capture the Tl isotope value of the overlying water column, which shows that Tl isotopes could be applied as a faithful deep time redox proxy. For the first time, we will present new data showing that Tl isotopes is tracking bottom water ocean oxygenation. We are applying this isotope system to ancient samples, testing the spatial and temporal variability of ocean oxygenation coinciding with major biogeochemical events.

  3. Thallium myocardial tomoscintigraphy: detection of ischemia during weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease. Tomoscintigraphie myocardique au thallium: detection de l'ischemie provoquee par le sevrage de la ventilation assistee chez le bronchiteux chronique

    Energy Technology Data Exchange (ETDEWEB)

    Andre, L.; Valette, H.; Obama, S.; Archambaud, F.; Richard, C.; Teboul, J.L.; Hebert, J.L.; Auzepy, P.; Desgrez, A. (Hopital de Bicetre, 94 - Le Kremlin-Bicetre (FR))

    1990-01-01

    In order to evidence myocardial ischemia-leading to ventricular dysfunction-during weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease, thallium myocardial tomography and gated blood pool studies were performed in 9 patients during mechanical ventilation and during weaning from mechanical ventilation. During the latter, results of gated blood pool studies showed a diffuse homogeneous left ventricular dysfunction. A fixed lower thallium uptake in the septum than in the lateral wall was found with the quantitative analysis of myocardial tomograms. Partial volume effect is likely the cause of this septal defect. The hypothesis of a diffuse ischemia cannot be excluded; but, without the absolute quantification of tomographic data, it cannot be proven.

  4. Studies on calcium phosphate precipitation: effects of metal ions used in dental materials.

    Science.gov (United States)

    Okamoto, Y; Hidaka, S

    1994-12-01

    The effects of 26 metal ions, of which 23 are used in dental materials, on the conversion of amorphous calcium phosphate (ACP) to hydroxyapatite (HAP) in vitro were studied. From the effects on both the rate of HAP transformation and induction time, effects of metal ions were classified into three types; inhibitory (in the order: nickel, tin, cobalt, manganese, copper, zinc, gallium, thallium, molybdenum, cadmium, antimony, magnesium, and mercury); ineffective (cesium, titanium, chromium, iron [ferrous], iridium, palladium, platinum, silver, gold, aluminum, and lead); and stimulatory (iron [ferric] and indium). These results suggest that metal ions used in dental materials may modify the precipitation of oral calcium phosphate.

  5. Technetium-99m pyrophosphate/thallium-201 dual-isotope SPECT imaging predicts reperfusion injury in patients with acute myocardial infarction after reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Akutsu, Yasushi; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Nishimura, Hideki; Hamazaki, Yuji; Kobayashi, Youichi [Showa University School of Medicine, Division of Cardiology, Department of Medicine, Tokyo (Japan); Suyama, Jumpei; Shinozuka, Akira; Gokan, Takehiko [Showa University School of Medicine, Department of Radiology, Tokyo (Japan)

    2009-02-15

    Microcirculatory failure after reperfusion is clinically indicated to cause reperfusion injury whereas excessive intracellular calcium ion overload is experimentally proved as a key mechanism of reperfusion injury. We hypothesized that technetium-99m ({sup 99m}Tc) pyrophosphate (Tc-PYP) uptake in injured but viable infarct-related myocardium with preserved myocardial perfusion after reperfusion estimated by thallium-201 ({sup 201}Tl) uptake would be associated with final functional recovery. Dual-isotope Tc-PYP/{sup 201}Tl single-photon emission computed tomography (SPECT) was performed 2 days after successful reperfusion therapy in patients with first acute myocardial infarction, and 50 patients (63 {+-} 13 years old, female 22%) with preserved {sup 201}Tl uptakes of {>=}50% in reperfused myocardium was followed for 1 month. Tc-PYP uptake was assessed as the heart-to-sternum (H/S) ratio. Two-dimensional echocardiography was also performed 2 days and 1 month after reperfusion to evaluate functional recovery. High Tc-PYP uptake, defined as the H/S ratio {>=}0.81, was predictive of chronic phase no functional recovery (73.7% in 14 of 19 patients with high uptake vs 16.1% in five of 31 patients without those, p < 0.0001). After adjustment for potential confounding variables, including electrocardiographic persistent ST segment elevation at 1 h after reperfusion, high Tc-PYP uptake remained independently predictive of no functional recovery with odds ratio of 8.7 (95% confidential interval = 2 to 38.7; p = 0.005). High Tc-PYP uptake in reperfused but viable infarct-related myocardium was a powerful predictor of no functional recovery, which may reflect excessive intracellular calcium ion overload caused by reperfusion injury. Tc-PYP/{sup 201}Tl dual-isotope SPECT imaging can provide prognostic information after reperfusion. (orig.)

  6. Studies of photon spectra from a thallium-204 foil source as an aid to dosimetry and shielding

    CERN Document Server

    Francis, T M

    1976-01-01

    Beta ray foil sources incorporating nuclides such as thallium-204, promethium-147 and strontium-90 plus yttrium-90 ar increasingly used in industrial devices such as thickness gauges. These sources are so constructed that they give rise to complex photon spectra containing low energy Bremsstrahlung and X-rays characteristic of the constructional materials. The energy response of practical monitoring instruments is such that they are likely to underestimate the dose due to such spectra unless they are calibrated using appropriate spectra. This report describes a series of measurements carried out on a commercially available thallium-204 foil source and five commonly used shielding materials. The measurements made with a NaI(T1) spectrometer have been corrected for instrumental distortions to obtain the photon spectra in air. These spectra are presented and have been used to compute dose in air with the help of published data on mass energy-absorption coefficients. Also included in the report are data derived f...

  7. Septal myocardial perfusion imaging with thallium-201 in the diagnosis of proximal left anterior descending coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Pichard, A.D.; Wiener, I.; Martinez, E.; Horowitz, S.; Patterson, R.; Meller, J.; Goldsmith, S.J.; Gorlin, R.; Herman, M.V.

    1981-07-01

    The use of myocardial perfusion imaging (MPI) to identify obstructive coronary disease of the left anterior descending coronary artery proximal to the first septal perforator (prox LAD) was studied in 60 patients. Perfusion of the septum and anteroapical areas with thallium-201 injected during exercise was compared to results of coronary arteriography. Septal MPI defect was found in 92.3% of patients with obstruction of the proximal LAD, 27.7% of patients with obstruction of LAD distal to first septal perforator, 0% in patients with obstructions involving right or circumflex arteries, and in 10.5% of patients without coronary disease. Anteroapical MPI defects were found with similar frequency in the three groups with obstructive coronary disease. Septal MPI defect had a sensitivity of 92.3% and specificity of 85.4% in the diagnosis of proximal LAD disease. Normal septal perfusion with thallium-201 virtually excluded proximal LAD disease.

  8. Usefulness of rest-redistribution thallium scan for the indication of PTCA in an interesting case with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Chiba, Hiroshi; Nishimura, Tsunehiko; Mitani, Isao; Matsuo, Takeshi; Uehara, Toshiisa; Hayashida, Kohei; Sumiyoshi, Tetsuya; Haze, Kazuo

    1988-04-01

    A 72-year-old woman with acute myocardial infarction was received coronary thrombolytic therapy. After percutaneous transluminal coronary recanalization (PTCR), the stenosis of LAD became from 99 % to 90 %. Left ventriculogram showed dyskinesis of anterior wall in acute phase. After PTCR, she complained of postinfarctional angina. Thus, in order to evaluate the viability of anterior wall, serial thallium scintigraphy was performed at rest, which showed perfusion defect and redistribution of anterior wall. After percutaneous transluminal coronary angioplasty (PTCA), anterior wall motion became almost normal. The perfusion defect of anterior wall was also gradually disappeared. The serial thallium scintigraphy at rest is an useful method not only to evaluate the viability of myocardium in acute myocardial infarction, but also to follow the effect of PTCA.

  9. Rearrangement of beta,gamma-unsaturated esters with thallium trinitrate: synthesis of indans bearing a beta-keto ester moiety

    Directory of Open Access Journals (Sweden)

    Silva Jr. Luiz F.

    2006-01-01

    Full Text Available The rearrangement of beta,gamma-unsaturated esters, such as 2-(3,4-dihydronaphthalen-1-yl-propionic acid ethyl ester, with thallium trinitrate (TTN in acetic acid leads to 3-indan-1-yl-2-methyl-3-oxo-propionic acid ethyl ester in good yield, through a ring contraction reaction. The new indans thus obtained feature a beta-keto ester moiety, which would be useful for further functionalization.

  10. Formic acid electrooxidation on thallium-decorated shape-controlled platinum nanoparticles: an improvement in electrocatalytic activity

    OpenAIRE

    Busó-Rogero, Carlos; Perales-Rondón, Juan V.; Farias, Manuel J.S.; Vidal-Iglesias, Francisco J.; Solla-Gullón, José; Herrero, Enrique; Feliu, Juan M.

    2014-01-01

    Thallium modified shape-controlled Pt nanoparticles were prepared and their electrocatalytic activity towards formic acid electrooxidation was evaluated in 0.5 M sulfuric acid. The electrochemical and in situ FTIR spectroscopic results show a remarkable improvement in the electrocatalytic activity, especially in the low potential region (around 0.1–0.2 V vs. RHE). Cubic Pt nanoparticles modified with Tl were found to be more active than the octahedral Pt ones in the entire range of Tl coverag...

  11. Usefulness and limitations of thallium-201 myocardial scintigraphy in delineating location and size of prior myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Niess, G.S.; Logic, J.R.; Russell, R.O. Jr.; Rackley, C.E.; Rogers, W.J.

    1979-05-01

    Thirty-two patients were evaluated at a mean of 7 +- 2 months after infarction with a 12-lead ECG, resting /sup 201/Tl myocardial scintigram, biplane left ventriculogram, and coronary angiograms. From the left ventriculogram, asynergy was quantified as percent abnormally contracting segment (% ACS), the percent of end-diastolic circumference which was either akinetic or dyskinetic. Using a computerized planimetry system, we expressed /sup 201/Tl perfusion defects as a percentage of total potential thallium uptake. Of 21 patients with ECG evidence of prior transmural infarction, a /sup 201/Tl defect was present in 20, and angiographic asynergy was present in all 21. The site of prior infarction by ECG agreed with the /sup 201/T1 defect location in 24 of 32 patients and with site of angiographic asynergy in 23 of 32 patients. Scintigraphic defects were present in only four of 10 patients with ACS less than or equal to 6%, but scintigraphic defects were found in 20 of 22 patients with ACS > 6%. Thallium defect size correlated marginally with angiographic left ventricular ejection fraction but correlated closely with angiographic % ACS. Thallium defect size was similar among patients with one-, two-, or three-vessel coronary artery disease (greater than or equal to 70% stenosis), but thallium defect size was larger in patients with electrocardiographic evidence of transmural infarction or pulmonary capillary wedge pressure > 12 mm Hg. Thus, resting /sup 201/T1 myocardial scintigraphy is useful in localizing and quantifying the extent of prior myocardial infarction, but is insensitive to small infarcts (ACS < 6%).

  12. Thallium isotopes in metallurgical wastes/contaminated soils: A novel tool to trace metal source and behavior.

    Science.gov (United States)

    Vaněk, Aleš; Grösslová, Zuzana; Mihaljevič, Martin; Ettler, Vojtěch; Trubač, Jakub; Chrastný, Vladislav; Penížek, Vít; Teper, Leslaw; Cabala, Jerzy; Voegelin, Andreas; Zádorová, Tereza; Oborná, Vendula; Drábek, Ondřej; Holubík, Ondřej; Houška, Jakub; Pavlů, Lenka; Ash, Christopher

    2018-02-05

    Thallium (Tl) concentration and isotope data have been recorded for contaminated soils and a set of industrial wastes that were produced within different stages of Zn ore mining and metallurgical processing of Zn-rich materials. Despite large differences in Tl levels of the waste materials (1-500mgkg-1), generally small changes in ε205Tl values have been observed. However, isotopically lighter Tl was recorded in fly ash (ε205Tl∼-4.1) than in slag (ε205Tl∼-3.3), implying partial isotope fractionation during material processing. Thallium isotope compositions in the studied soils reflected the Tl contamination (ε205Tl∼-3.8), despite the fact that the major pollution period ended more than 30 years ago. Therefore, we assume that former industrial Tl inputs into soils, if significant, can potentially be traced using the isotope tracing method. We also suggest that the isotope redistributions occurred in some soil (subsurface) horizons, with Tl being isotopically heavier than the pollution source, due to specific sorption and/or precipitation processes, which complicates the discrimination of primary Tl. Thallium isotope analysis proved to be a promising tool to aid our understanding of Tl behavior within the smelting process, as well as its post-depositional dynamics in the environmental systems (soils). Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Thallium-isotopic compositions of euxinic sediments as a proxy for global manganese-oxide burial

    Science.gov (United States)

    Owens, Jeremy D.; Nielsen, Sune G.; Horner, Tristan J.; Ostrander, Chadlin M.; Peterson, Larry C.

    2017-09-01

    Thallium (Tl) isotopes are a new and potentially powerful paleoredox proxy that may track bottom water oxygen conditions based on the global burial flux of manganese oxides. Thallium has a residence time of ∼20 thousand years, which is longer than the ocean mixing time, and it has been inferred that modern oxic seawater is conservative with respect to both concentration and isotopes. Marine sources of Tl have nearly identical isotopic values. Therefore, the Tl sinks, adsorption onto manganese oxides and low temperature oceanic crust alteration (the dominant seawater output), are the primary controls of the seawater isotopic composition. For relatively short-term, ∼million years, redox events it is reasonable to assume that the dominant mechanism that alters the Tl isotopic composition of seawater is associated with manganese oxide burial because large variability in low temperature ocean crust alteration is controlled by long-term, multi-million years, average ocean crust production rates. This study presents new Tl isotope data for an open ocean transect in the South Atlantic, and depth transects for two euxinic basins (anoxic and free sulfide in the water column), the Cariaco Basin and Black Sea. The Tl isotopic signature of open ocean seawater in the South Atlantic was found to be homogeneous with ε205Tl = -6.0 ± 0.3 (±2 SD, n = 41) while oxic waters from Cariaco and the Black Sea are -5.6 and -2.2, respectively. Combined with existing data from the Pacific and Arctic Oceans, our Atlantic data establish the conservatism of Tl isotopes in the global ocean. In contrast, partially- and predominantly-restricted basins reveal Tl isotope differences that vary between open-ocean (-6) and continental material (-2) ε205Tl, scaling with the degree of restriction. Regardless of the differences between basins, Tl is quantitatively removed from their euxinic waters below the chemocline. The burial of Tl in euxinic sediments is estimated to be an order of magnitude

  14. Thallium isotopes as a potential tracer for the origin of cratonic eclogites

    Science.gov (United States)

    Nielsen, Sune G.; Williams, Helen M.; Griffin, William L.; O'Reilly, Suzanne Y.; Pearson, Norman; Viljoen, Fanus

    2009-12-01

    Cratonic eclogites are inferred to originate either from subducted ocean crust or mantle melts accreted onto the roots of continents. These models have different implications for the growth of continents, but it is currently difficult to determine the origin of individual eclogite suites. Upper ocean crust altered at low temperatures and marine sediments both display high thallium (Tl) concentrations and strongly fractionated Tl isotope signatures relative to the ambient upper mantle. In this study we carry out the first examination of the suitability of Tl isotopes as a tracer for an ocean-crust origin of cratonic eclogites. We have analysed the Tl isotope composition of clinopyroxene and garnet in six eclogites from the Kaalvallei and Bellsbank kimberlite pipes in South Africa. Minerals were pre-cleaned with an HCl leaching technique and the leachates display variably light Tl isotope ratios. These most likely reflect low-temperature hydrothermal alteration occurring after eruption of the kimberlite that carried the eclogites to the surface. The leached mineral pairs all display identical Tl isotope ratios, strongly suggesting that the source of the analysed Tl is identical for each mineral pair. It is, however, not possible to exclude the possibility that the analysed Tl originates from kimberlitic material that was not removed by the cleaning procedure. Only one of the six samples exhibits a Tl isotope composition different from ambient mantle. Assuming that the Tl isotope signatures indeed represent the eclogite minerals and not any form of contamination, the Tl isotope composition in this sample is consistent with containing a minor component (low temperatures. Thallium isotopes may become one of the most sensitive indicators for the presence of low-T altered ocean crust because of the stark contrast in Tl concentration and isotopic composition between the mantle and altered ocean crust. In fact, no other chemical or isotopic tracer could have provided an

  15. Thallium-201 SPECT in the diagnosis of head and neck cancer.

    Science.gov (United States)

    Valdés Olmos, R A; Balm, A J; Hilgers, F J; Koops, W; Loftus, B M; Tan, I B; Muller, S H; Hoefnagel, C A; Gregor, R T

    1997-06-01

    The accuracy of SPECT with 201Tl-chloride for the diagnosis of primary tumors, lymph node metastases and recurrences in head and neck cancer was evaluated for clinical applicability. SPECT images, obtained 60 min after administration of 150 MBq 201Tl-chloride, were compared with clinical, CT and/or MRI and histology results. In addition, whole-body images were obtained to detect distant metastases. In 79 patients studied for primary tumors (principally larynix, hypopharynx, oropharynx, nasopharynx and oral cavity), 201Tl SPECT correctly identified 69 of 73 (95% versus 88% for CT/MRI) histologically confirmed malignancies including 63 squamous-cell carcinomas. The method localized four occult naso- and oropharynx carcinomas not seen on CT/MRI and was correctly negative in two patients without tumor and in three of four patients with no confirmed primary tumor in the head and neck. With respect to regional spread, only patients who had cervical lymph node dissection were evaluated, and the findings were recorded per side of the neck. Thallium-201 SPECT correctly identified metastases in 31 of 36 neck dissections with proven lymph node involvement (86%), was correctly negative in nine and false-positive in one. Although the sensitivity of CT/MRI was clearly higher (97%), considerably more false-positive cases affected its accuracy (81% versus 87% for SPECT). In 30 patients investigated for recurrences, 201Tl SPECT correctly identified 27 of 29 microscopically confirmed tumor sites (93%) and was correctly negative in seven. Sensitivity of CT/MRI was lower (76%), and a greater number of false-positives (seven versus three for SPECT) further decreased its accuracy (64% versus 87% for SPECT). Distant metastases were detected in five patients. Thallium-201 SPECT appears to be an accurate method for the diagnosis of head and neck cancer. The method is particularly useful for detection of occult head and neck tumors and for assessing recurrences. It also may be of

  16. Thallium in spawn, juveniles, and adult common toads (Bufo bufo) living in the vicinity of a zinc-mining complex, Poland.

    Science.gov (United States)

    Dmowski, Krzysztof; Rossa, Monika; Kowalska, Joanna; Krasnodębska-Ostręga, Beata

    2015-01-01

    A breeding population of the common toad Bufo bufo living in the vicinity of a Zn-Pb smelting works in Bukowno, Poland was studied for the presence of thallium. Tl concentration was measured in the bottom sediments of the spawning pond, in the laid eggs, in juveniles after metamorphosis, and in the selected tissues of the adult individuals. A very high concentration of Tl was detected in the spawn (13.97 ± 8.90 mg/kg d.w.). In 50% of the spawn samples, levels exceeded 20 mgTl/kg d.w. The issue of maternal transfer of thallium from females to oocytes is discussed. Due to a significant accumulation of thallium, spawn analysis can be used as a sensitive indicator of the presence of this element in the environment and may replace more invasive methods that involve the killing of adult animals. In those regions that are abundant in Zn-Pb ores, the spawn of amphibians may be a very important source of thallium contamination for predators. From among all tissues of the Bukowno adult toads, the livers have shown the highest accumulation of thallium (mean 3.98 mg/kg d.w. and maximum value--18.63). For as many as 96.5% of livers, concentrations exceeded 1.0 mgTl/kg d.w. which is treated as indicative of poisoning.

  17. In-situ pre-concentration through repeated sampling and pyrolysis for ultrasensitive determination of thallium in drinking water by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Liu, Liwei; Zheng, Huaili; Xu, Bincheng; Xiao, Lang; Chigan, Yong; Zhangluo, Yilan

    2018-03-01

    In this paper, a procedure for in-situ pre-concentration in graphite furnace by repeated sampling and pyrolysis is proposed for the determination of ultra-trace thallium in drinking water by graphite furnace atomic absorption spectrometry (GF-AAS). Without any other laborious enrichment processes that routinely result in analyte loss and contamination, thallium was directly concentrated in the graphite furnace automatically and subsequently subject to analysis. The effects of several key factors, such as the temperature for pyrolysis and atomization, the chemical modifier, and the repeated sampling times were investigated. Under the optimized conditions, a limit of detection of 0.01µgL -1 was obtained, which fulfilled thallium determination in drinking water by GB 5749-2006 regulated by China. Successful analysis of thallium in certified water samples and drinking water samples was demonstrated, with analytical results in good agreement with the certified values and those by inductively coupled plasma mass spectrometry (ICP-MS), respectively. Routine spike-recovery tests with randomly selected drinking water samples showed satisfactory results of 80-96%. The proposed method is simple and sensitive for screening of ultra-trace thallium in drinking water samples. Copyright © 2017. Published by Elsevier B.V.

  18. The ECG component of Thallium-201 exercise testing impacts on cardiac intervention rates

    Energy Technology Data Exchange (ETDEWEB)

    Deague, J.; Salehi, N.; Grigg, L.; Lichtenstein, M.; Better, N. [Royal Melbourne Hospital, Parkville, VIC (Australia). Departments of Nuclear Medicine and Cardiology

    1998-06-01

    Full text: Thallium exercise testing (Tlex) offers superior sensitivity and specificity to exercise electrocardiography (ECG), but the value of the ECG data in Tlex remains poorly studied. While a normal Tlex is associated with an excellent prognosis, patients with a positive Tlex have a higher cardiac event rate. We aimed to see if a negative ECG Component of the Tlex (ECGTl) was associated with an improved outcome compared with a positive ECGTl, in those patients with a reversible Tlex defect. We followed 100 consecutive patients retrospectively with a reversible defect on Tlex (50 with negative and 50 with positive ECGTI) for 12 months. The ECG was reviewed as positive (1mm ST depression 0.08 seconds after J point or >2mm if on digoxin or prior ECG changes), negative, equivocal or uninterpretable. We excluded patients with pharmacological testing, and those with equivocal or uninterpretable ECGs. End-points included angiography, cardiac interventions and cardiac event rate (CER) incorporating unstable angina, acute myocardial infarction, and cardiac death. In conclusion 24% of patients with reversible defects on Tlex who had a negative ECGTI still proceeded to PTCA or CABG. Those with a positive ECGTI had a higher incidence of angiography and cardiac revascularisation, but this difference was only evident in patients with mild to moderate reversibility

  19. Redox-controlled release dynamics of thallium in periodically flooded arable soil.

    Science.gov (United States)

    Antić-Mladenović, Svetlana; Frohne, Tina; Kresović, Mirjana; Stärk, Hans-Joachim; Savić, Dubravka; Ličina, Vlado; Rinklebe, Jörg

    2017-07-01

    To our knowledge, this is the first work to mechanistically study the impact of the redox potential (E H ) and principal factors, such as pH, iron (Fe), manganese (Mn), dissolved organic carbon (DOC), dissolved inorganic carbon (DIC), chlorides (Cl - ) and sulfates (SO 4 2- ), on the release dynamics of thallium (Tl) in periodically flooded soil. We simulated flooding using an automated biogeochemical microcosm system that allows for systematical control of pre-defined redox windows. The E H value was increased mechanistically at intervals of approximately 100 mV from reducing (-211 mV) to oxidizing (475 mV) conditions. Soluble Tl levels (0.02-0.28 μg L -1 ) increased significantly with increases in E H (r = 0.80, p soils along with a determination of the Tl species and monitoring of the Tl content in plants to achieve more detailed insight into soluble Tl behavior. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. EFFECTS OF THALLIUM ON THE LARVAL DEVELOPMENT OF LUCILIA SERICATA MEIGEN 1826 AND PMI ESTIMATION

    Directory of Open Access Journals (Sweden)

    Arif Gökhan BAŞARAN

    2011-08-01

    Full Text Available Determination of larval growth rate of and forensic analysis of the age of Calliphoridae larvae on a corpse are useful evidence in legal investigations for the estimation of exact death time and time duration after death; post mortem interval. However many factors, such as temperature, tissue type and contamination of drugs and toxins, effect larval development of blow fly larvae and consequently theestimation of post mortem interval. The present study examined the larval growth rate of a forensically important blow fly species, Lucilia sericata Meigen 1826 in different concentrations (0,12; 0,25; 0,50; 1 and 2 μg/g of toxic heavy metal Thallium under controlled laboratory conditions. Body length and weight, death ratio of larvae and pupa between experimental and control groups were compared. Results demonstrated that the development rate of larvae between uncontaminated and contaminated diets varies significantly. In short, they molted later, reached maximum length more slowly and sometimesproduced significantly smaller pupae in contaminated food source. These results emphasized that the importance of determining the contamination rate of toxins in tissue for the forensic entomologist,while using development rates from standard curves based on larvae fed non-contaminated mediums.

  1. Value of transient dilation of the left ventricular cavity on stress thallium scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Hiroki; Shiga, Kouji; Umamoto, Ikuo (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1991-02-01

    This study was undertaken to evaluate the value of transient dilation of the left ventricular cavity on stress thallium scintigraphy in 80 patients with ischemic heart disease (IHD) and 50 with hypertrophic cardiomyopathy (HCM). Twenty persons without either coronary artery stenosis or heart disease were served as controls. Areas surrounded by maximum count points on the line of each 10deg on the short axis slice through the mid-cavity of the left ventricle were obtained at 10 minutes and at 3 hours after exercise. Transient dilation index (TDI) was obtained by dividing the area on early image by that on delayed image. TDI was significantly higher in patients with two or three vessel disease in the IHD group than the control group. High TDI was observed in 8% for one vessel disease, 40% for two vessel disease, and 80% for three vessel disease, contributing to the detection of multivessel IHD. In the HCM group of 80 patients, 24 (48%) had high TDI which was frequently associated with a history of chest pain and positive ECG findings at exercise. When these 24 HCM patients underwent exercise blood pool scintiscanning, left ventricular enddiastolic volume was similar before and at 10 minutes after exercise. These findings suggest that transient dilation of the left ventricular cavity after exercise may reflect subendocardial ischemia in both IHD and HCM. TDI would become a useful indicator for transient dilation of the left ventricular cavity. (N.K.).

  2. Clinicopathologic correlation study of thallium-201 myocardial scintigraphy in diagnosis of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Chida, Kouji; Sugiura, Masaya; Ohkawa, Shin-ichiro

    1987-05-01

    In a series of 1,000 consecutive autopsy cases, we evaluated the clinical utility of thallium-201 (Tl-201) myocardial scintigraphy and electrocardiography (ECG) in 101 patients who had been studied while alive. Fifty-five cases had myocardial infarctions (MI) at autopsy. The Tl-201 scintigram and ECG in diagnosis of MI showed sensitivities of 68 % and 60 %, specificities of 87 % and 83 %, and diagnostic accuracies of 76 % and 70 %, respectively. The sensitivity of the Tl-201 scintigram was 70 % in anterior MI, 80 % in postero-inferior MI, 25 % in lateral and subendocardial infarction. The sensitivity was 88 % for large massive MI, but was low in scattered (50 %) or middle-sized MI (17 %). The diagnostic limit of the resolution of Tl-201 scintigrams was 4.5 cm in long diameter. All 8 cases with MI of less than 4 cm could not be diagnosed with the technique. There were 48 cases of large MI (more than 5 cm), but 8 cases could not be diagnosed by scintigraphy because of non-transmural or scattered MI. A comparison of the Tl-201 scintigram and ECG showed that 27 cases out of 60 cases were diagnosed by both methods, 14 only by the Tl-201 scintigram, 9 only by ECG and 10 by neither method.

  3. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Takuhisa; Shibuya, Noritoshi (Kawatana National Hospital, Nagasaki (Japan)); Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD[>=]10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD[>=]10 and age[>=]15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age[>=]15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author).

  4. Role of relativity in high-pressure phase transitions of thallium.

    Science.gov (United States)

    Kotmool, Komsilp; Chakraborty, Sudip; Bovornratanaraks, Thiti; Ahuja, Rajeev

    2017-02-20

    We demonstrate the relativistic effects in high-pressure phase transitions of heavy element thallium. The known first phase transition from h.c.p. to f.c.c. is initially investigated by various relativistic levels and exchange-correlation functionals as implemented in FPLO method, as well as scalar relativistic scheme within PAW formalism. The electronic structure calculations are interpreted from the perspective of energetic stability and electronic density of states. The full relativistic scheme (FR) within L(S)DA performs to be the scheme that resembles mostly with experimental results with a transition pressure of 3 GPa. The s-p hybridization and the valence-core overlapping of 6s and 5d states are the primary reasons behind the f.c.c. phase occurrence. A recent proposed phase, i.e., a body-centered tetragonal (b.c.t.) phase, is confirmed with a small distortion from the f.c.c. phase. We have also predicted a reversible b.c.t. → f.c.c. phase transition at 800 GPa. This finding has been suggested that almost all the III-A elements (Ga, In and Tl) exhibit the b.c.t. → f.c.c. phase transition at extremely high pressure.

  5. High thallium concentrations in soils from sites of historical Ag, Pb, and Zn mining in western Małopolska (S Poland

    Directory of Open Access Journals (Sweden)

    Woch M. W.

    2013-04-01

    Full Text Available The aim of this study was to assess thallium concentration in topsoil originating from sites of historical mining of Ag, Pb and Zn in western Małopolska (S Poland. Soil samples were collected from 63 sites, sieved, ground and digested in hot HClO4. Thallium concentration was measured with an atomic absorption spectrometer. Thallium concentrations averaged 20.84 mg kg-1 and varied from 4.42 to 49.82 mg kg-1. In all studied soils they exceeded values typical for uncontaminated soils (0.02 to 2.8 mg Tl kg-1. This indicates that Tl contamination may threaten the environment and public health. Routine monitoring of Tl contamination in southern Poland is required.

  6. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    Energy Technology Data Exchange (ETDEWEB)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-02-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease.

  7. Influence of the Dirac-Hartree-Fock starting potential on the parity-nonconserving electric-dipole-transition amplitudes in cesium and thallium

    Science.gov (United States)

    Perger, W. F.; Das, B. P.

    1987-01-01

    The parity-nonconserving electric-dipole-transition amplitudes for the 6s1/2-7s1/2 transition in cesium and the 6p1/2-7p1/2 transition in thallium have been calculated by the Dirac-Hartree-Fock method. The effects of using different Dirac-Hartree-Fock atomic core potentials are examined and the transition amplitudes for both the length and velocity gauges are given. It is found that the parity-nonconserving transition amplitudes exhibit a greater dependence on the starting potential for thallium than for cesium.

  8. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    Science.gov (United States)

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  9. Self-propagating high-temperature synthesis (SHS) and microwave-assisted combustion synthesis (MACS) of the thallium superconducting phases

    Science.gov (United States)

    Bayya, S. S.; Snyder, R. L.

    1994-05-01

    This paper explores the speed of reaction as a parameter to minimizing thallium loss. Self-propagating high-temperature synthesis (SHS) and microwave-assisted combustion synthesis (MACS) were developed for the synthesis of Tl-2212 and Tl-2223 superconductors using Cu metal powder as a fuel. A kitchen microwave oven was used to carry out MACS reactions. The samples were reacted for few seconds and led to the formation of the superconducting phases. Further explorations and modifications in the processing could lead to the formation of single phases by MACS.

  10. Tracking along-arc sediment inputs to the Aleutian arc using thallium isotopes

    Science.gov (United States)

    Nielsen, Sune G.; Yogodzinski, Gene; Prytulak, Julie; Plank, Terry; Kay, Suzanne M.; Kay, Robert W.; Blusztajn, Jerzy; Owens, Jeremy D.; Auro, Maureen; Kading, Tristan

    2016-05-01

    Sediment transport from the subducted slab to the mantle wedge is an important process in understanding the chemical and physical conditions of arc magma generation. The Aleutian arc offers an excellent opportunity to study sediment transport processes because the subducted sediment flux varies systematically along strike (Kelemen et al., 2003) and many lavas exhibit unambiguous signatures of sediment addition to the sub-arc mantle (Morris et al., 1990). However, the exact sediment contribution to Aleutian lavas and how these sediments are transported from the slab to the surface are still debated. Thallium (Tl) isotope ratios have great potential to distinguish sediment fluxes in subduction zones because pelagic sediments and low-temperature altered oceanic crust are highly enriched in Tl and display heavy and light Tl isotope compositions, respectively, compared with the upper mantle and continental crust. Here, we investigate the Tl isotope composition of lavas covering almost the entire Aleutian arc a well as sediments outboard of both the eastern (DSDP Sites 178 and 183) and central (ODP Hole 886C) portions of the arc. Sediment Tl isotope compositions change systematically from lighter in the Eastern to heavier in the Central Aleutians reflecting a larger proportion of pelagic sediments when distal from the North American continent. Lavas in the Eastern and Central Aleutians mirror this systematic change to heavier Tl isotope compositions to the west, which shows that the subducted sediment composition is directly translated to the arc east of Kanaga Island. Moreover, quantitative mixing models of Tl and Pb, Sr and Nd isotopes reveal that bulk sediment transfer of ∼0.6-1.0% by weight in the Eastern Aleutians and ∼0.2-0.6% by weight in the Central Aleutians can account for all four isotope systems. Bulk mixing models, however, require that fractionation of trace element ratios like Ce/Pb, Cs/Tl, and Sr/Nd in the Central and Eastern Aleutians occurs after

  11. Controls on thallium uptake during hydrothermal alteration of the upper ocean crust

    Science.gov (United States)

    Coggon, Rosalind M.; Rehkämper, Mark; Atteck, Charlotte; Teagle, Damon A. H.; Alt, Jeffrey C.; Cooper, Matthew J.

    2014-11-01

    Hydrothermal circulation is a fundamental component of global biogeochemical cycles. However, the magnitude of the high temperature axial hydrothermal fluid flux remains disputed, and the lower temperature ridge flank fluid flux is difficult to quantify. Thallium (Tl) isotopes behave differently in axial compared to ridge flank systems, with Tl near-quantitatively stripped from the intrusive crust by high temperature hydrothermal reactions, but added to the lavas during low temperature reaction with seawater. This contrasting behavior provides a unique approach to determine the fluid fluxes associated with axial and ridge flank environments. Unfortunately, our understanding of the Tl isotopic mass balance is hindered by poor knowledge of the mineralogical, physical and chemical controls on Tl-uptake by the ocean crust. Here we use analyses of basaltic volcanic upper crust from Integrated Ocean Drilling Program Hole U1301B on the Juan de Fuca Ridge flank, combined with published analyses of dredged seafloor basalts and upper crustal basalts from Holes 504B and 896A, to investigate the controls on Tl-uptake by mid-ocean ridge basalts and evaluate when in the evolution of the ridge flank hydrothermal system Tl-uptake occurs. Seafloor basalts indicate an association between basaltic uptake of Tl from cold seawater and uptake of Cs and Rb, which are known to partition into K-rich phases. Although there is no clear relationship between Tl and K contents of seafloor basalts, the data do not rule out the incorporation of at least some Tl into the same minerals as the alkali elements. In contrast, we find no relationship between the Tl content and either the abundance of secondary phyllosilicate minerals, or the K, Cs or Rb contents in upper crustal basalts. We conclude that the uptake of Tl and alkali elements during hydrothermal alteration of the upper crust involves different processes and/or mineral phases compared to those that govern seafloor weathering. Furthermore

  12. Luminescent one- and two-dimensional extended structures and a loosely associated dimer based on platinum(II)-thallium(I) backbones.

    Science.gov (United States)

    Forniés, Juan; García, Ana; Lalinde, Elena; Moreno, M Teresa

    2008-05-05

    Neutralization reactions between (NBu4)2[ trans-Pt(C 6F5)2(CN)2] 1 and (NBu4)2[cis-Pt(C6F5)2(CN)2] 2 with TlPF 6 have been carried out, and the resulting structures of [trans,trans,trans-Tl2{Pt(C6F5)2(CN)2}.(CH3COCH3) ] n [4.(CH3COCH3)2] n and {Tl[Tl{cis-Pt(C6F5)2(CN)2}].(H2O)} n [5.(H2O)] n have been determined by X-ray crystallography. Remarkably, the change from trans to cis geometry on the platinum substrate causes a significant decrease in the Pt(II)...Tl(I) metallophilic interaction. Thus, the platinum center in the trans fragment easily connects with two Tl(I) ions forming a distorted pseudo-octahedron PtTl2, which generates a final two-dimensional layered structure by secondary additional intermolecular Tl(I)...N(CN) interactions. However, the [cis-Pt(C6F5)2(CN)2] (2-) fragment interacts strongly with just one Tl center leading to an extended helical [-Pt-Tl-Pt-Tl-] n(n-) chain. In this case, the second thallium center neutralizes the anionic chain mainly through Tl...N(CN) ( intra) and Tl...F(C 6F 5) (intra and inter)actions. The reaction of TlPF 6 with the monoanionic fragment (NBu4)[cis-Pt(C6F5)2(CN)(PPh2C[triple bond]CPh)] 3 yields the discrete associated dimer [Tl{cis-Pt(C6F5)2(CN)(PPh2C[triple bond]CPh)}] 2 [ 6] 2. Dimer [ 6] 2 could be described as two square pyramids with the thallium atoms in the apical positions, connected through Tl...N(cyano) interactions. The final heteropolynuclear Pt-Tl complexes, except 4 at room temperature, show bright emission in the solid state when irradiated with UV-vis radiation, in contrast to the precursors 1 and 3, which are not luminescent. This difference indicates that the emissions in 4- 6 are presumably related to the interaction between the metal centers. The Pt-Tl bonding interactions and, consequently, the emissive properties are lost in solution at room temperature, as shown by the conductivity and NMR measurements. However, variable-concentration luminescence measurements in glassy acetonitrile solutions

  13. Chemistry and phase evolution during roasting of toxic thallium-bearing pyrite.

    Science.gov (United States)

    Lopez-Arce, Paula; Garcia-Guinea, Javier; Garrido, Fernando

    2017-08-01

    In the frame of a research project on microscopic distribution and speciation of geogenic thallium (Tl) from contaminated mine soils, Tl-bearing pyrite ore samples from Riotinto mining district (Huelva, SW Spain) were experimentally fired to simulate a roasting process. Concentration and volatility behavior of Tl and other toxic heavy metals was determined by quantitative ICP-MS, whereas semi-quantitative mineral phase transitions were identified by in situ thermo X-Ray Diffraction (HT-XRD) and Scanning Electron Microscopy with Energy Dispersive Spectroscopy (SEM-EDS) analyses after each firing temperature. Sample with initial highest amount of quartz (higher Si content), lowest quantity of pyrite and traces of jarosite (lower S content) developed hematite and concentrated Tl (from 10 up to 72 mg kg-1) after roasting at 900 °C in an oxidizing atmosphere. However, samples with lower or absent quartz content and higher pyrite amount mainly developed magnetite, accumulating Tl between 400 and 500 °C and releasing Tl from 700 up to 900 °C (from 10-29 mg kg-1 down to 4-1 mg kg-1). These results show the varied accumulative, or volatile, behaviors of one of the most toxic elements for life and environment, in which oxidation of Tl-bearing Fe sulfides produce Fe oxides wastes with or without Tl. The initial chemistry and mineralogy of pyrite ores should be taken into account in coal-fired power stations, cement or sulfuric acid production industry involving pyrite roasting processes, and steel, brick or paint industries, which use iron ore from roasted pyrite ash, where large amounts of Tl entail significant environmental pollution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Measurement of the parity nonconserving neutral weak interaction in atomic thallium

    Energy Technology Data Exchange (ETDEWEB)

    Bucksbaum, P.H.

    1980-11-01

    This thesis describes an experiment to measure parity nonconservation in atomic thallium. A frequency doubled, flashlamp pumped tunable dye laser is used to excite the 6P/sub 1/2/(F = 0) ..-->.. 7P/sub 1/2/(F = 1) transition at 292.7 nm, with circularly polarized light. An electrostatic field E of 100 to 300 V/cm causes this transition to occur via Stark induced electric dipole. Two field free transitions may also occur: a highly forbidden magnetic dipole M, and a parity nonconserving electric dipole epsilon/sub P/. The latter is presumed to be due to the presence of a weak neutral current interaction between the 6p valence electron and the nucleus, as predicted by gauge theories which unite the electromagnetic and weak interactions. Both M and epsilon/sub P/ interfere with the Stark amplitude ..beta..E to produce a polarization of the 7P/sub 1/2/ state. This is measured with a circularly polarized infrared laser beam probe, tuned to the 7P/sub 1/2/ ..-->.. 8S/sub 1/2/ transition. This selectively excites m/sub F/ = +1 or -1 components of the 7P/sub 1/2/ state, and the polarization is seen as an asymmetry in 8S ..-->.. 6P/sub 3/2/ fluorescence when the probe helicity is reversed. The polarization due to M is ..delta../sub M/ = -2M/(BETAE). It is used to calibrate the analyzing efficiency. The polarization due to epsilon/sub P/ is ..delta../sub P/ = 2i epsilon/sub P//(..beta..E), and can be distinguished from ..delta../sub M/ by its properties under reversal of the 292.7 nm photon helicity and reversal of the laser direction. A preliminary measurement yielded a parity violation in agreement with the gauge theory of Weinberg and Salam.

  15. MRI and thallium-201 SPECT in the prediction of survival in glioma

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Maaike J. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Medical Center Haaglanden, Department of Neurology, PO Box 432, The Hague (Netherlands); Berkhof, Johannes [VU University Medical Center, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Hoekstra, Otto S. [VU University Medical Center, Department of Nuclear Medicine and PET Research, Amsterdam (Netherlands); Bosma, Ingeborg; Sizoo, Eefje M.; Heimans, Jan J.; Reijneveld, Jaap C.; Postma, Tjeerd J. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Sanchez, Esther [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Lagerwaard, Frank J. [VU University Medical Center, Department of Radiation Oncology, Amsterdam (Netherlands); Buter, Jan [VU University Medical Center, Department of Medical Oncology, Amsterdam (Netherlands); Noske, David P. [VU University Medical Center, Department of Neurosurgery and Neuro-Oncology Research Group, Amsterdam (Netherlands)

    2012-06-15

    This paper aims to study the value of MRI and Thallium 201 ({sup 201}Tl) single-photon emission computed tomography (SPECT) in the prediction of overall survival (OS) in glioma patients treated with temozolomide (TMZ) and to evaluate timing of radiological follow-up. We included patients treated with TMZ chemoradiotherapy for newly diagnosed glioblastoma multiforme (GBM) and with TMZ for recurrent glioma. MRIs and {sup 201}Tl SPECTs were obtained at regular intervals. The value of both imaging modalities in predicting OS was examined using Cox regression analyses. Altogether, 138 MRIs and 113 {sup 201}Tl SPECTs in 46 patients were performed. Both imaging modalities were strongly related to OS (P {<=} 0.02). In newly diagnosed GBM patients, the last follow-up MRI (i.e., after six adjuvant TMZ courses) and SPECT (i.e., after three adjuvant TMZ courses) were the strongest predictors of OS (P = 0.01). In recurrent glioma patients, baseline measurements appeared to be the most predictive of OS (P < 0.01). The addition of one imaging modality to the other did not contribute to the prediction of OS. Both MRI and {sup 201}Tl SPECT are valuable in the prediction of OS. It is adequate to restrict to one of both modalities in the radiological follow-up during treatment. In the primary GBM setting, MRI after six adjuvant TMZ courses contributes significantly to the prediction of survival. In the recurrent glioma setting, baseline MRI appears to be a powerful predictor of survival, whereas follow-up MRIs during TMZ seem to be of little additional value. (orig.)

  16. Synthesis, calorimetric, structural and conductivity studies in a new thallium selenate tellurate adduct compound

    Energy Technology Data Exchange (ETDEWEB)

    Ktari, L. [Laboratoire de l' Etat Solide (LES), Faculte des Sciences de Sfax, 3000 Sfax (Tunisia); Abdelhedi, M. [Laboratoire de l' Etat Solide (LES), Faculte des Sciences de Sfax, 3000 Sfax (Tunisia); Laboratoire Leon Brouillon LLB, CEA Saclay, 91191 Gif-Sur-Yvette Cedex (France); Bouhlel, N. [Laboratoire de l' Etat Solide (LES), Faculte des Sciences de Sfax, 3000 Sfax (Tunisia); Dammak, M., E-mail: meddammak@yahoo.fr [Laboratoire de l' Etat Solide (LES), Faculte des Sciences de Sfax, 3000 Sfax (Tunisia); Cousson, A. [Laboratoire Leon Brouillon LLB, CEA Saclay, 91191 Gif-Sur-Yvette Cedex (France)

    2009-08-05

    The crystal structure of the thallium selenate tellurate Tl{sub 2}SeO{sub 4}.Te(OH){sub 6} (TlSeTe) was determined by X-ray diffraction method. The title compound crystallizes in the monoclinic system with P2{sub 1}/c space group. The following parameters are: a = 12.358(3) A; b = 7.231(1) A; c = 11.986(2) A; {beta} = 111.092(2){sup o}; Z = 4. The structure can be regarded as being built of isolated TeO{sub 6} octahedra and SeO{sub 4} tetrahedra. The Tl{sup +} cations are intercalated between these kinds of polyhedra. The main feature of this structure is the coexistence of two different and independent anions (SeO{sub 4}{sup 2-} and TeO{sub 6}{sup 6-}) in the same unit cell. The structure is stable due to O-H...O hydrogen bonds which link tetrahedral and octahedral groups. Crystals of Tl{sub 2}SeO{sub 4}.Te(OH){sub 6} undergo three endothermal transitions at 373, 395 and 437 K. These transitions are detected by DSC and analyzed by dielectric measurements with impedance spectroscopy. The evolution of conductivity versus temperature showed the presence of a protonic conduction phase transition at 437 K. The phase transition at 373 K can be related to a structural phase transition, whereas the one at 395 K is ascribed as likely due to a ferroelectric-paraelectric phase transition.

  17. Quantitative evaluation of thallium-201 myocardial scintigram in coronary artery diseases

    Energy Technology Data Exchange (ETDEWEB)

    Mikada, Ken-etsu (Akita Univ. (Japan). School of Medicine)

    1992-11-01

    Quantitative indices from circumferential profile curves of thallium-201 ([sup 201]Tl) myocardial scintigram were evaluated for diagnostic utility in coronary artery diseases (CAD). Myocardial [sup 201]Tl scintigrams with single photon emission computed tomography (SPECT) were obtained 5 minutes (early) and 4 hours (delayed) after exercise in 20 normal subjects and 66 cases of CAD, of which 20 were angina pectoris without myocardial infarction (AP), 14 were subendocardial infarction (non-QMI) and 32 were Q-wave infarction (QMI). Tl counts, %Tl uptake and washout ratio (WR) were measured in 81 segments (9 apical segments of the slice from the longitudinal axis and all 72 segments of two slices from the short axis). A mean early defect (MED), a mean delayed defect (MDD), a mean delta washout rate (MDR), and a [Sigma] delayed defect ([Sigma]DD) were calculated from the areas which were below the two standard deviations of the mean %Tl uptake in normal subjects. A mean filling-in (MFI) was calculated from the difference of the %Tl uptake between early and delayed curves in each patient. In patients with CAD, the MED and MFI were higher, but MDW was lower with a more severe coronary stenosis, indicating that these indices were useful to detect myocardial hypo-perfuion. In severely stenotic regions, the MDD was higher in QMI than in AP and non-QMI, indicating that the ratio of infarct to the myocardium in the region was higher in QMI. In QMI, [Sigma]DD correlated well (r=0.723) with Total Wall Motion Scores with two-dimentional echocardiography which was directly related with infarct size. Further, MED, MFI and MDW were improved after aortocoronary bypass only in patients with patent graft. It is concluded that this quantitative evaluation with [sup 201]Tl-SPECT can provide an objective and quantitative estimate of regional myocardial ischemia and infarct. (author).

  18. Thallium-201 for cardiac stress tests: residual radioactivity worries patients and security.

    Science.gov (United States)

    Geraci, Matthew J; Brown, Norman; Murray, David

    2012-12-01

    A 47-year-old man presented to the Emergency Department (ED) in duress and stated he was "highly radioactive." There were no reports of nuclear disasters, spills, or mishaps in the local area. This report discusses the potential for thallium-201 (Tl-201) patients to activate passive radiation alarms days to weeks after nuclear stress tests, even while shielded inside industrial vehicles away from sensors. Characteristics of Tl-201, as used for medical imaging, are described. This patient was twice detained by Homeland Security Agents and searched after he activated radiation detectors at a seaport security checkpoint. Security agents deemed him not to be a threat, but they expressed concern regarding his health and level of personal radioactivity. The patient was subsequently barred from his job and sent to the hospital. Tl-201 is a widely used radioisotope for medical imaging. The radioactive half-life of Tl-201 is 73.1h, however, reported periods of extended personal radiation have been seen as far out as 61 days post-administration. This case describes an anxious, but otherwise asymptomatic patient presenting to the ED with detection of low-level personal radiation. Documentation should be provided to and carried by individuals receiving radionuclides for a minimum of five to six half-lives of the longest-lasting isotope provided. Patients receiving Tl-201 should understand the potential for security issues; reducing probable tense moments, confusion, and anxiety to themselves, their employers, security officials, and ED staff. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Usefulness of thallium-201 SPECT in the evaluation of tumor natures in intracranial meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tetsuji; Nakano, Takahiro; Asano, Kenichiroh; Shimamura, Norihito; Ohkuma, Hiroki [Hirosaki University Graduate School of Medicine, Department of Neurosurgery, Hirosaki (Japan)

    2011-11-15

    Although intracranial meningiomas are regarded as benign tumors, some of them behave clinically as malignant tumors. Past reports suggest that MIB 1 and vascular endothelial growth factor (VEGF) in postoperative tumor specimens correlate with the aggressive nature of tumors, but preoperative prediction of such a nature is more useful for therapeutic planning for the tumor. The purpose of this study was to assess the usefulness of preoperative thallium-201 chloride single-photon emission computed tomography (Tl SPECT) to evaluate biological behavior in intracranial meningiomas. Tl SPECT was performed on 39 patients with intracranial meningioma and Tl uptake indices were calculated. The difference in the Tl uptake index between atypical meningiomas and other pathological types of meningioma was evaluated. Moreover, correlation of Tl uptake indices with the MIB1 labeling index was estimated. Tl uptake indices were also compared between VEGF strongly positive and weakly positive meningiomas. The delayed index of atypical meningioma was significantly higher than that of the other pathological types (p = 0.036). Significant correlation was found between the Tl uptake index in the delayed image and MIB1 labeling index (p < 0.0001, R{sup 2} = 0.36). Moreover, VEGF strongly positive meningiomas exhibited a significantly higher Tl uptake index compared to VEGF weakly positive meningiomas in both the early image and the delayed image (p = 0.029, 0.023, respectively). Tl uptake index may be a possible preoperative surrogate marker of MIB1 and VEGF that is useful in detecting aggressive natures in intracranial meningiomas. (orig.)

  20. Reduced left ventricular cavitary activity ("black hole sign") in thallium-201 SPECT perfusion images of anteroapical transmural myocardial infarction.

    Science.gov (United States)

    Civelek, A C; Shafique, I; Brinker, J A; Durski, K; Weiss, J L; Links, J M; Natarajan, T K; Ozguven, M A; Wagner, H N

    1991-11-01

    Apparently reduced left ventricular (LV) cavitary thallium activity in both planar and tomographic perfusion images has been previously observed by these and other investigators. With single-photon emission computerized tomography, we have clinically noted that this "black hole sign" was associated with an aneurysm in the setting of a transmural anterior or anteroapical perfusion defect. We have now prospectively studied the etiology and predictive value of this sign in 84 consecutive patients with an anterior, anteroapical transmural perfusion defect. Of the 84 patients, 49 had both LV aneurysm (confirmed by contrast ventriculography, echocardiography or gated blood pool studies) and a black hole sign. Only 1 patient with an aneurysm did not have the black hole sign, and 2 without aneurysm did. Thus, it is concluded that this sign is highly accurate in diagnosing LV aneurysm. Because thallium-201 single-photon emission computerized tomography imaging is often performed as one of the first diagnostic tests soon after myocardial infarction, this has important clinical management implications.

  1. The analysis of thallium in geological materials by radiochemical neutron activation and x-ray fluorescence spectrometry: a comparison

    Energy Technology Data Exchange (ETDEWEB)

    McGoldrick, P.J.; Robinson, P. [Tasmania Univ., Sandy Bay, TAS (Australia)

    1993-12-31

    Carrier-based radiochemical neutron activation (RNAA) is a precise and accurate technique for the analysis of Tl in geological materials. For about a decade, until the mid-80s, a procedure modified from Keays et al. (1974) was used at the University of Melbourne to analyse for Tl in a wide variety of geological materials. Samples of powdered rock weighing several hundred milligrams each were irradiated in HIFAR for between 12 hours and 1 week, and subsequently fused with a sodium hydroxide - sodium peroxide mixture and several milligrams of inactive Tl carrier. Following acid digestion of the fusion mixture anion exchange resin was used to separate Tl from the major radioactive rock constituents. The Tl was then stripped from the resin and purified as thallium iodide and a yield measured gravimetrically. Activity from {sup 204}Tl (a {beta}-emitter with a 3 8 year half-life) was measured and Tl determined by reference to pure chemical standards irradiated and processed along with the unkowns. Detection limits for the longer irradiations were about one part per billion. Precision was monitored by repeat analyses of `internal standard` rocks and was estimated to be about five to ten percent (one standard deviation). On the other hand, X-ray fluorescence spectrometry (XRF) was seen as an excellent cost-effective alternative for thallium analysis in geological samples, down to 1 ppm. 6 refs. 1 tab., 1 fig.

  2. Pentoxifylline (Trental) does not inhibit dipyridamole-induced coronary hyperemia: Implications for dipyridamole-thallium-201 myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.A.; Slinker, B.K. (Univ. of Vermont College of Medicine, Burlington (USA))

    1990-06-01

    Dipyridamole-thallium-201 imaging is often performed in patients unable to exercise because of peripheral vascular disease. Many of these patients are taking pentoxifylline (Trental), a methylxanthine derivative which may improve intermittent claudication. Whether pentoxifylline inhibits dipyridamole-induced coronary hyperemia like other methylxanthines such as theophylline and should be stopped prior to dipyridamole-thallium-201 imaging is unknown. Therefore, we studied the hyperemic response to dipyridamole in seven open-chest anesthetized dogs after pretreatment with either pentoxifylline (0, 7.5, or 15 mg/kg i.v.) or theophylline (3 mg/kg i.v.). Baseline circumflex coronary blood flows did not differ significantly among treatment groups. Dipyridamole significantly increased coronary blood flow before and after 7.5 or 15 mm/kg i.v. pentoxifylline (p less than 0.002). Neither dose of pentoxifylline significantly decreased the dipyridamole-induced hyperemia, while peak coronary blood flow was significantly lower after theophylline (p less than 0.01). We conclude that pentoxyifylline does not inhibit dipyridamole-induced coronary hyperemia even at high doses.

  3. Thallium-201 scintigraphy after dipyridamole infusion with low-level exercise. III Clinical significance and additional diagnostic value of ST segment depression and angina pectoris during the test

    NARCIS (Netherlands)

    G-J. Laarman (GertJan); P.W.J.C. Serruys (Patrick); J.F. Verzijlbergen (Fred); C.A.P.L. Ascoop (Carl); J. Azar

    1990-01-01

    textabstractIntravenous dipyridamole thallium testing is a useful alternative procedure for assessing coronary artery disease (CAD) in patients who are unable to perform maximal exercise tests. Ischaemic ST segment depression and angina pectoris are frequently observed during the test, in particular

  4. Indium-111 antimyosin antibody imaging and thallium-201 imaging. A comparative myocardial scintigraphic study using single-photon emission computed tomography in patients with myocarditis and dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takehiko; Matsumori, Akira; Nohara, Ryuji; Konishi, Junji; Sasayama, Shigetake [Kyoto Univ. (Japan). Faculty of Medicine; Tamaki, Nagara

    1997-10-01

    Indium-111 antimyosin antibody imaging (a tracer of myocardial necrosis) and thallium-201 imaging (a tracer of myocardial perfusion) were compared in patients with myocarditis and dilated cardiomyopathy. The distribution of each tracer and antimyosin/thallium-201 overlapping were evaluated with single-photon emission computed tomography (SPECT). Scintigraphic data were classified into 5 patterns according to the distribution of both images and were compared with histologic findings of endomyocardial biopsy: AM-D, intense and diffuse antimyosin uptake and no perfusion abnormality (active myocarditis); AM-L, localized antimyosin uptake and no perfusion abnormality (active myocarditis); HM, no antimyosin uptake with or without perfusion abnormality (healed myocarditis); DCM-NH, diffuse antimyosin uptake and inhomogeneous thallium-201 uptake (dilated cardiomyopathy); DCM-PD, diffuse or localized antimyosin uptake and myocardial perfusion defect(s) (dilated cardiomyopathy). Patients with dilated-phase hypertrophic cardiomyopathy were frequently found in the DCM-PD group. Taken together, comparative antimyosin/thallium-201 SPECT images are useful for evaluating the activity of myocarditis and ongoing myocardial damage even in areas with no perfusion in patients with dilated cardiomyopathy. (author)

  5. Thallium-201 myocardial scintigraphy in patients with normal coronary arteries and normal left ventriculogram. Comparison with hemodynamic, metabolic and morphologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Loesse, B.; Kuhn, H.; Rafflenbeul, D.; Kroenert, H.; Hort, W.; Feinendegen, L.E.; Loogen, F.

    1980-01-01

    36 consecutive patients with chest pain and/or severe ventricular dysrhythmias, but normal coronary arteries and normal left ventriculogram, underwent thallium-201 myocardial imaging at rest and during exercise. The myocardial scintigram was abnormal in 27 patients (group A) and normal in only 9 patients (group B).

  6. Tracing subducted sediment inputs to the Ryukyu arc-Okinawa Trough system: Evidence from thallium isotopes

    Science.gov (United States)

    Shu, Yunchao; Nielsen, Sune G.; Zeng, Zhigang; Shinjo, Ryuichi; Blusztajn, Jerzy; Wang, Xiaoyuan; Chen, Shuai

    2017-11-01

    Sediments are actively subducted in virtually every arc worldwide. However, quantifying their contributions to arc lavas and thereby establishing budgets of how sediments participate in slab-mantle interaction is challenging. In this contribution we use thallium (Tl) abundances and isotopic compositions of lavas from the Ryukyu arc (including south Kyushu) and its back-arc basin, Okinawa Trough, to investigate the influence of sediments from arc to back-arc. We also present extensive geochemical data for sediments and altered oceanic crust (AOC) outboard of the northern (DSDP Sites 296, 442B, 443 and 444) and central (DSDP Sites 294 and 295) part of the Ryukyu arc. The Tl isotopic compositions of sediments change systematically from lighter outboard of northern Ryukyu arc to heavier outboard of central Ryukyu arc. The feature reflects the dominance of terrigenous material and pelagic sedimentation outboard of the northern and central Ryukyu arc, respectively. Central and northern sections of Ryukyu arc and Okinawa Trough display larger range of Tl isotopic variation than southern section, which is consistent with more pelagic provenance for sediments outboard of central and northern Ryukyu arcs than that of expected sediments outboard of southern Ryukyu arc. Identical Tl, Sr, Nd and Pb isotope variations are found when comparing arc and back arc lavas, which indicates that sediments fluxes also account for the Tl isotopic variations in the Okinawa Trough lavas. Two-end-member mixing models of Tl with Pb, Sr and Nd isotopes require sediment inputs ofsediment end members predict very similar sediment fluxes when using Tl, Sr, Nd and Pb isotopes, which indicates that fractionation of these elements must have happened after mixing between mantle and sediments. This conclusion is corroborated by model calculations of mixing between sediment melts with fractionated Sr/Nd ratios and mantle wedge, which show that no arc lava plot on such mixing lines. Thus bulk sediment

  7. Comparison of arbutamine stress and treadmill exercise thallium-201 SPECT: Hemodynamics, safety profile and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kiat, H.; Berman, D.S. [Cedars-Sinai Medical Centre, Los Angeles, California, LA (United States)

    1998-02-01

    Full text: Arbutamine (ARB), a new pharmacologic stress agent with enhanced chronotropic property compared to dobutamine, was compared with treadmill (TM) exercise testing (Ex) in a multicenter study using thallium-201 (Tl) SPECT. Of the total of 184 patients who underwent ARB, 69 also had TM stress and quantitative coronary angiography. Fifty-eight patients with a low pretest likelihood of CAD also underwent ARB study for evaluation of test specificity (normalcy rate). Tl scans were scored by a central laboratory using a 20 segment (seg)/scan visual analysis (5 point system: 0=normal, 4-absent uptake). Maximum heart rate (HR) by ARB and Ex was 122 vs 141 bpm (p<0.05). Mean %HR change from baseline was similar (79% vs 82%, respectively, p=ns). Maximum systolic BP for ARB and Ex was 173 vs 175 mmHg, and mean % change from baseline was 24% vs 28% (p=ns). Sensitivity for detecting CAD (270% stenosis) by ARB Tl was 94% and 97% by Ex Tl (p=ns). Stress Tl SPECT segmental agreement for presence of defect between ARB and Ex was 92% (kappa=0.8, p<0.001). Exact segmental stress Tl score (0-4 grading) agreement was 83 % (kappa=0.7, p<0.001). Among 346 segs with stress defects by both ARB and Ex defect reversibility agreement was 86% (kappa=0.7, p<0.001). The normalcy rate for ARB TI-SPECT among patients with a low likelihood of CAD was 90%. Adverse events were mostly mild (tremor: 23%, flushing: 10%, headache: 10%, paraesthesia: 8%, dizziness: 8%, hot flushes: 4%). Arrhythimia of clinical concern occurred in 8% (10/122) of ARB patients who had cardiac catheterisation and in 1.4% (1/69) of patients who had stress Tl. Of all 184 patients with ARB stress, ARB was discontinued due to arrhythmia in 7(5%) and 1 patient had IV Metoprolol for frequent ventricular couplets. Sustained arrhythmias were not observed

  8. Thallium Isotopes Tracking Mn-Oxide Burial - A Proxy for Deoxygenation During Oceanic Anoxic Event 2

    Science.gov (United States)

    Ostrander, C.; Owens, J. D.; Nielsen, S.

    2015-12-01

    Thallium (Tl) is proving to be a useful paleoredox proxy given that the Tl isotope composition of seawater is highly dependent on the magnitude of manganese (Mn) oxide burial in the ocean. In turn, Mn oxides require oxygen at the sediment-water interface to precipitate, linking the Tl isotope cycle to ocean oxygenation. Currently, the marine residence time of Tl is ~20kyrs and the Tl isotope composition of seawater is invariant, which suggests Tl isotopes could be a global tracer of marine Mn-oxide burial. Importantly, recent research suggests sediments deposited under a euxinic water column faithfully record the Tl isotope value of the overlying oxic water column (e.g. Black Sea and Cariaco Basin). Therefore, analysis of organic-rich black shales may prove useful in evaluating the seawater Tl isotope composition of past oceans and, hence, large-scale burial of Mn-oxides and the extent of bottom water ocean oxygenation. A logical test for this proxy is during the well-studied Cenomanian-Turonian boundary event termed Oceanic Anoxic Event 2 (OAE-2) at ~94 Ma. It is known that the global extent of anoxia and euxinia increased during this event, however, to what extent global bottom water deoxygenation occured is unconstrained. If deep water deoxygenation occurred, it would be hypothesized that Mn-oxide precipitation would decrease, resulting in a positive Tl isotope excursion during OAE-2. We have analyzed the Tl isotope composition of organic-rich black shales from Site 1258 of the Ocean Drilling Program (ODP) spanning the period before, during, and after OAE-2. Based on Fe redox proxies, the entire section is euxinic and thus no Mn-oxides are present (i.e. no local redox changes). Before the event, Tl isotope compositions are similar or slightly heavier than modern seawater values. Just prior to the onset of OAE-2, a positive shift occurs and is maintained until recovery, slightly before the termination of the event. The shift to heavier values and subsequent

  9. Geochemical translocation of thallium in the sediments from the North River, China

    Science.gov (United States)

    Liu, J.

    2016-12-01

    Thallium (Tl) is a highly toxic rare heavy metal. As a sulphophile element, it usually occurs in numerous sulphide minerals (such as pyrite, galena, sphlerite). Guangdong north region, known as the hometown of nonferrous metals, has abundant containing Tl mineral resources. Numerous industrial activities, such as mining, smelting, and electroplating are also flourishing. In 2010, a serious Tl pollution in the North River (a major river in the Northern Guangdong Province) shocked the society. The Tl pollution in water appeared to be under control after that incident. But in fact, even if the wastewater discharge of pollution sources has been controlled, the potential risk of heavy metal pollution in the sediments of the North River still exists, for the metals are easy to precipitate and accumulate into sediment from water. So far, Tl pollution in sediments has been studied to a very limited extent. In this paper, we investigated the content and vertical distribution characteristics of Tl and some other related heavy metals in a typical sediment profile from the North River by using inductively coupled plasma mass spectrometry (ICP-MS). Then the Pb isotopic compositions in the sediments were measured by using multi-inductively coupled plasma mass spectrometry (MC-ICP-MS). Several sediments from typical layers were also subjected to sequential extraction procedure for investigating the geochemical fractions of Tl. The risk of Tl and other metal pollution was finally assessed by calculating geo-accumulation indexes (Igeo) and potential ecological risk. The results showed that: (1) Tl concentrations range 1.03 mg/kg to 3.13 mg/kg with a mean of 1.89 mg/kg, three times higher than that in local background soil; (2) Tl content generally increased with depth with some fluctuations and significant correlations were found between Tl and Pb, Zn, Cd, Cu, and Ni; (3) About 46 % to 70 % in sediment cores were resided in the residual fraction; (4) Igeo showed that the studied

  10. Source and distribution of sedimentary thallium in the Bohai Sea: Implications for hydrodynamic forces and anthropogenic impact

    Science.gov (United States)

    Hu, Ningjing; Liu, Jihua; Shi, Xuefa

    2015-04-01

    Source and distribution of sedimentary thallium in the Bohai Sea: Implications for hydrodynamic forces and anthropogenic impact Hu Ningjing, Liu Jihua, Shi Xuefa First Institute of Oceanography, State Oceanic Administration, Qingdao 266061, China Thallium (Tl), a non-essential and highly toxic trace metal, is listed as priority toxic pollutant by the United States Environmental Protection Agency (USEPA) (Keith and Telliard, 1979). However, its geochemical cycling in aquatic environment has received far less attention than that of many other trace metals. This has been attributed to relatively little commercial interest in Tl and, until recently, problems inherent in its detection at environmental concentrations (Meeravali and Jiang, 2008). In this study, we investigated the sources, distribution and fate of Tl in surface sediments of the Bohai Sea (BS), China, based on the datasets of total Tl and chemical speciation of Tl of 408 surface sediment samples in the total entire BS. The enrichment factors and chemical speciation of Tl indicated that Tl in BS was dominated by natural Tl, although anthropogenic Tl contamination was observed in the Liuguhe River mouth; the mud deposits are the sinks of Tl and the regional currents and tide systems play a key role on the accumulation of Tl in BS. The distribution of Tl consistent with that of MnO and Fe2O3 as well as the level of Fe-Mn fraction is relatively high, indicating MnO and Fe2O3 influence the geochemical behaviors of Tl in the BS. Although the positive correlation between Tl and TOC is observed for the samples in the BS, however, level of Tl in oxidizable faction could be neglected, suggesting TOC might not be a major factor affecting the concentration of Tl in BS. The low proportion of Tl in the non-residual fraction dominated by the Fe-Mn oxides suggested that the labile Tl was controlled by the Fe-Mn oxides and Tl has a low bioavailability and a minor potential threat to biota in BS. Acknowledgements: this work

  11. Fractionation and Mobility of Thallium in Volcanic Ashes after Eruption of Eyjafjallajökull (2010) in Iceland.

    Science.gov (United States)

    Karbowska, Bozena; Zembrzuski, Wlodzimierz

    2016-07-01

    Volcanic ash contains thallium (Tl), which is highly toxic to the biosphere. The aim of this study was to determine the Tl concentration in fractions of volcanic ash samples originating from the Eyjafjallajökull volcano. A sequential extraction scheme allowed for a study of element migration in the environment. Differential pulse anodic stripping voltammetry using a flow measuring system was selected as the analytical method to determine Tl content. The highest average content of Tl in volcanic ash was determined in the fraction entrapped in the aluminosilicate matrix (0.329 µg g(-1)), followed by the oxidizable fraction (0.173 µg g(-1)). The lowest content of Tl was found in the water soluble fraction (0.001 µg g(-1)); however, this fraction is important due to the fact that Tl redistribution among all the fractions occurs through the aqueous phase.

  12. ion with phenolate ions

    Indian Academy of Sciences (India)

    Administrator

    Photoinduced electron transfer (PET) reaction of homoleptic tris-chelated polypyridine ruthenium(II) complexes with phenolate ions is sensitive to the structure of the ligand of the Ru(II) complex as well as of the phenolate ions 1. In recent years 2 the photophysical and photochemical properties of Ru(II) complexes based on ...

  13. Determination of gold, indium, tellurium and thallium in the same sample digest of geological materials by atomic-absorption spectroscopy and two-step solvent extraction

    Science.gov (United States)

    Hubert, A.E.; Chao, T.T.

    1985-01-01

    A rock, soil, or stream-sediment sample is decomposed with hydrofluoric acid, aqua regia, and hydrobromic acid-bromine solution. Gold, thallium, indium and tellurium are separated and concentrated from the sample digest by a two-step MIBK extraction at two concentrations of hydrobromic add. Gold and thallium are first extracted from 0.1M hydrobromic acid medium, then indium and tellurium are extracted from 3M hydrobromic acid in the presence of ascorbic acid to eliminate iron interference. The elements are then determined by flame atomic-absorption spectrophotometry. The two-step solvent extraction can also be used in conjunction with electrothermal atomic-absorption methods to lower the detection limits for all four metals in geological materials. ?? 1985.

  14. Comparison of glucose-insulin-thallium-201 infusion single photon emission computed tomography (SPECT), stress-redistribution-reinjection thallium-201 SPECT and low dose dobutamine echocardiography for prediction of reversible dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Hiroki; Kondo, Makoto; Motohiro, Masayuki; Usami, Satoru [Shimada Municipal Hospital, Shizuoka (Japan)

    2001-12-01

    The usefulness of glucose-insulin-thallium-201 (GI-Tl) infusion single photon emission computed tomography (SPECT) in predicting reversible dysfunction has not been evaluated, so the present study recruited 20 patients with regional ischemic dysfunction for investigation. All patients underwent GI-Tl SPECT, post-stress Tl reinjection imaging and low dose dobutamine echocardiography. The diagnostic accuracy of these 3 techniques in predicting functional recovery was evaluated by receiver operating characteristic (ROC) analysis. In segments with functional recovery, regional Tl activities of GI-Tl SPECT were significantly higher than those of reinjection imaging (p<0.05), although there were no significant differences in segments without recovery. The area under the ROC curve for GI-Tl SPECT (0.75{+-}0.06) was greater than that for reinjection imaging (0.68{+-}0.07). The optimal cutoff values to identify viable myocardium were considered to be 55% of peak activity for GI-Tl SPECT and 50% for reinjection imaging. At this cutoff point, the sensitivity and specificity for detection of functional recovery were, respectively, 85% and 61% for GI-Tl SPECT, and 73% and 61% for reinjection imaging. Dobutamine echocardiography had the same sensitivity (85%), but lower specificity (48%) than GI-Tl SPECT. Continuous infusion of GI-Tl solution enhances regional Tl uptake compared with conventional post-stress reinjection imaging. This study suggests that GI-Tl SPECT is superior to reinjection imaging and dobutamine echocardiography in predicting functional recovery after ischemic left ventricular dysfunction. (author)

  15. Detection and dosimetry of gamma ray emitted from thallium-201 and technetium-99m based on chemiluminescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Shourian, Mostafa [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Tavakoli, Hassan, E-mail: tavakoli@ibb.ut.ac.i [Faculty of Medicine, Department of Physiology and Biophysics, Faculty of Medicine, Baqiyatollah University of Medical Sciences, P.O. Box 19395-6558, Tehran (Iran, Islamic Republic of); Ghourchian, Hedayatollah, E-mail: hadi@ibb.ut.ac.i [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Rafiee-Pour, Hossain-Ali [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of)

    2010-09-15

    This report describes the detection and dosimetry of gamma ray emitted from Thallium-201 ({sup 201}Tl) and Technetium-99m ({sup 99m}Tc) based on chemiluminescence technique. H{sub 2}O{sub 2} produced by two gamma emitter radioisotopes of {sup 201}Tl and {sup 99m}Tc were quantitatively measured by chemiluminescence method. Upon producing H{sub 2}O{sub 2} in a luminol alkaline solution, in the presence of diperiodatocuprate, as catalyst a chemical reaction was accrued and consequently the emitted light was measured. The determined H{sub 2}O{sub 2} concentration was correlated with the gamma ray detection and dosimetry. The sensitivity of chemiluminescence technique for {sup 201}Tl and {sup 99m}Tc dosimetry was determined to be 0.20 and 0.08 MBq/l (Mega Becquerel per liter) respectively (R.S.D. = %5, N = 3). The plotted calibration curves showed detection limits of 3.24 and 1.76 MBq/l for {sup 201}Tl and {sup 99m}Tc, respectively.

  16. Myocardial infarction diagnosis with body surface potential mapping, electrocardiography, vectorcardiography and thallium-201 scintigraphy: a correlative study with left ventriculography.

    Science.gov (United States)

    Ackaoui, A; Nadeau, R; Sestier, F; Savard, P; Primeau, R; Lemieux, R; Descary, M C

    1985-01-01

    In 35 subjects with typical or atypical angina and/or documented myocardial infarction (MI), body surface potential maps (BSPMs), ECG, VCG and rest Thallium-201 (T1-201) have been compared to left ventriculography (LVG). BSPMs were recorded with 26 ECGs, and BSPM abnormalities for MI cases were considered to be areas of normally positive potentials that have become negative. Subjects with MI were classified according to the segmental localization and degree of asynergy on LVG. Moderate anterolateral and apical asynergy were found to correlate with BSPM diagnosis of anterolateral MI and ischemia, severe anterolateral and apical asynergy with BSPM diagnosis of anterolateral MI and ischemia, and moderate diaphragmatic and/or posterobasal asynergy with BSPM diagnosis of posterior MI. Simultaneous anterior and posterior asynergy were found for BSPM diagnosis of anterior with posterior MI. Subjects with no LVG asynergy had normal BSPMs. BSPM diagnosis had the highest correlation coefficient with the LVG diagnosis (r = 0.88). ECG and VCG showed similar results with r = 0.65 and 0.71 respectively, while T1-201 had r = 0.55. The examination of our BSPMs, as well as the ECG, VCG and T1-201, did not permit to detect apical damage in presence of anterior MI, and posterobasal damage in the presence of inferoposterior MI. It is concluded that BSPMs are slightly superior to ECG and VCG for diagnosis of MI.

  17. Nondestructive method for quantifying thallium dopant concentrations in CsI:Tl crystals.

    Science.gov (United States)

    Miller, Stuart R; Ovechkina, Elena E; Bennett, Paul; Brecher, Charles

    2013-12-01

    We report a quantitative method for using X-ray fluorescence (XRF) to nondestructively measure the true content of Tl dopant in CsI:Tl scintillator crystals. The instrument is the handheld LeadTracer™, originally developed at RMD Instruments for measuring Pb concentration in electronic components. We describe both the measurement technique and specific findings on how changes in crystal size and growth parameters affect Tl concentration. This method is also applicable to numerous other activator ions important to scintillators, such as Ce(3+) and Eu(2+). © 2013 Elsevier Ltd. All rights reserved.

  18. Two new examples of very short thallium-transition metal contacts

    DEFF Research Database (Denmark)

    Karanovic, Ljiljana; Poleti, Dejan; Balic Zunic, Tonci

    2008-01-01

    Two new sulphosalts Tl3Ag3Sb2S6, (1) and Tl(3)Ag(3)AS(2)S(6), (2) were prepared in reaction of synthetic binary sulfides: argentite (Ag2S), carlinite (Tl2S) and orpiment (As2O3) or stibnite (Sb2S3), and their crystal structures have been determined using single-crystal data. The compounds are iso....... It is also pointed out that if only valence shell electrons are considered (Tl-Ag)(2+) group is isoelectronic with the (Hg-Hg)(2+) ion, therefore new examples of short Tl-Ag contacts could be expected. (C) 2007 Elsevier B.V. All rights reserved....

  19. New Proton-Ionizable, Calixarene-Based Ligands for Selective Metal Ion Separations

    Energy Technology Data Exchange (ETDEWEB)

    Bartsch, Richard A.

    2012-06-04

    The project objective was the discovery of new ligands for performing metal ion separations. The research effort entailed the preparation of new metal ion complexing agents and polymers and their evaluation in metal ion separation processes of solvent extraction, synthetic liquid membrane transport, and sorption. Structural variations in acyclic, cyclic, and bicyclic organic ligands were used to probe their influence upon the efficiency and selectivity with which metal ion separations can be performed. A unifying feature of the ligand structures is the presence of one (or more) side arm with a pendent acidic function. When a metal ion is complexed within the central cavity of the ligand, ionization of the side arm(s) produces the requisite anion(s) for formation of an overall electroneutral complex. This markedly enhances extraction/transport efficiency for separations in which movement of aqueous phase anions of chloride, nitrate, or sulfate into an organic medium would be required. Through systematic structural variations, new ligands have been developed for efficient and selective separations of monovalent metal ions (e.g., alkali metal, silver, and thallium cations) and of divalent metal ion species (e.g., alkaline earth metal, lead, and mercury cations). Research results obtained in these fundamental investigations provide important insight for the design and development of ligands suitable for practical metal ion separation applications.

  20. Thallium in spawn, juveniles, and adult common toads (Bufo bufo) living in the vicinity of a zinc-mining complex, Poland

    OpenAIRE

    Dmowski, Krzysztof; Rossa, Monika; Kowalska, Joanna; Krasnodębska-Ostręga, Beata

    2014-01-01

    A breeding population of the common toad Bufo bufo living in the vicinity of a Zn-Pb smelting works in Bukowno, Poland was studied for the presence of thallium. Tl concentration was measured in the bottom sediments of the spawning pond, in the laid eggs, in juveniles after metamorphosis, and in the selected tissues of the adult individuals. A very high concentration of Tl was detected in the spawn (13.97 ± 8.90 mg/kg d.w.). In 50 % of the spawn samples, levels exceeded 20 mgTl/kg d.w. The iss...

  1. Effects of potassium channel opener on the kinetics of thallium-201 in in-vitro and in-vivo

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.; Kim, E. J.; Ahn, B. C.; Chae, S. C.; Lee, K. B. [College of Medicine, Kyungpook National Univ., Taegu (Korea, Republic of); Kim, C. K. [Mt. Sinai Medical School, New York (United States)

    1997-07-01

    Potassium channel opener (K-opener) opens membrane ATP-sensitive K{sup +}-channel and induces and increase in potassium efflux from cells. K-openers are powerful smooth muscle relaxants and currently used as antihypertensive, antianginal drugs or bronchodilators in clinic. Pharmacologic potency of newly synthesized K-opener is being evaluated with efflux capacity of preincubated Rb-83 from the isolated aortic vascular tissue preparation. Thallium has similar characteristics to those of rubidium and potassium in vivo. To evaluate the effect of pinacidil (a potent K-opener) on Tl-201 biokinetics, we have performed uptake/washout studies in cultured myocytes, and mice biodistribution study. Primary culture of spontaneous contracting myocytes was undertake from hearts of newborn Sprague-Dawley rat. Different concentration of pinacidil (100nM or 10uM) was co-incubated with Tl-201 in HBSS buffer to evaluate its effect on cellular uptake, or challenged to myocyte preparations pre-incubated with Tl-201 for washout study. Pinacidil was injected into mice simultaneous or 10-min after Tl-201 injection, and organ uptake and whole body retention ratio was measured using gamma counter or dose calibrator. Co-incubation of pinacidil with Tl-201 resulted in a decrease in Tl uptake into myocytes by 1.6 - 2.5 times, and an increase in washout by 1.6 - 3.1 times. Pinacidil injection resulted in mild decrease in blood, heart and liver uptake in mice, bur renal uptake was markedly decreased in a dose dependent manner. These results suggest that the pinacidil Tl-201 kinetics and may potentially affect the interpretation of Tl-201 myocardial imaging.

  2. Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Lee, Jong Doo; Cho, Seung Yun; Shim, Won Heum; Ha, Jong Won; Kim, Han Soo; Kwon, Hyuk Moon; Jang, Yang Soo; Chung, Nam Sik; Kim, Sung Soon [Yonsei University College of Medicine, Seoul (Korea, Republic of); Park, Chang Yun; Kim, Young Soo [Inje University College of Medicine, Seoul (Korea, Republic of)

    1993-07-15

    To compare the myocardial viability in patients suffering from total occlusion of the right coronary artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) (300 approx 350 mu Ci) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA (200-250 mu Ci) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar and SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 reinjection. Intravenous T1-201 reinjection (six pts) or {sup 99m}Tc-MIBI (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201(IV T1-201) images, EGG, and ventriculography. Intracoronary TI-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  3. Disease stage classification in hypertrophic cardiomyopathy by dual analysis of iodine-123-labeled metaiodobenzylguanidine and thallium-201 myocardial scintigraphies

    Energy Technology Data Exchange (ETDEWEB)

    Hiasa, Go [Ehime Univ., Matsuyama (Japan). School of Medicine

    2001-08-01

    Many patients with hypertrophic cardiomyopathy (HCM) gradually changes from typical myocardial hypertrophy to dilated cardiomyopathy-like features. However, it is difficult to estimate the disease stage in HCM. To determine the disease stage, dual analysis of iodine-123-labeled metaiodobenzylguanidine ({sup 123}I-MIBG) and thallium-201 ({sup 201}Tl) myocardial scintigraphies were performed in 108 HCM patients. According to the scintigraphic distribution patterns, patients were divided into three groups. Group A (n=15): normal distributions of both {sup 123}I-MIBG and {sup 201}Tl, group B (n=71): normal {sup 201}Tl and low {sup 123}I-MIBG patterns, group C (n=22): low distributions of both scintigraphies. The decrease in {sup 201}Tl uptake was observed in only group C. Concerning {sup 123}I-MIBG, heart-to-mediastinum ratio (H/M) and washout rate (WOR) had good correlations with left ventricular systolic functions. H/M was decreased and WOR was increased in order of C, B and A groups. Left ventricular diastolic function reflected by isovolumic relaxation time was longer in group B than in group A. Attenuated left ventricular hypertrophy, enlarged left ventricular volumes, impaired left ventricular functions and serious clinical symptoms were observed in only group C. Myocardial sympathetic abnormalities in group B may be mainly due to myocardial hypertrophy, and those in group C may be due to myocardial injury. Dual analysis of {sup 123}I-MIBG and {sup 201}Tl scintigraphies may be useful to classify disease stages of HCM. (author)

  4. Comparative study of body surface isopotential map, left ventriculogram and thallium-201 myocardial scintigram in patients with old lateral myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Naoyuki

    1988-01-01

    In 16 patients with old lateral myocardial infarction, body surface isopotential maps and 12 lead electrocardiograms were compared with left ventriculographic findings. In addition 8 of these subjects were performed thallium-201 myocardial scintigraphy in order to determine the location and extent of myocardial necrosis. Common 12 lead electrocardiographic findings of the subjects were initial Q waves more than 30 msec and inverted T waves in only aVL lead. The patients were classified into 4 groups according to the location and extent of ventricular wall motion abnormalities group I (6 cases) showed hypokinesis in the anterior segment, group II (5 cases): akinesis in the anterior segment and hypokinesis in the seg. 6, group III (4 cases): hypokinesis in the anterior segment and seg. 7, group IV (1 case): hypokinesis in the anterior segment and seg. 4, 7. And each of the 4 groups demonstrated characteristic findings of surface isopotential maps. Group II with coexisting hypokinesis in the seg. 6 showed surface isopotential maps additional pattern of anterior myocardial infarction, and group III with coexisting hypokinesis in the seg. 7 showed additional patterns of posterior myocardial infarction. The classification according to the abnormality of ventricular wall motion was also conformed with the thallium-201 myocardial scintigraphic findings except one case. These results suggest that body surface isopotential map is more useful than the 12 lead electrocardiogram in detecting the location and extent of left ventricular wall motion abnormality in patients with old lateral myocardial infarction. (author) 53 refs.

  5. Serial thallium-201 imaging at rest in patients with unstable and stable angina pectoris: relationship of myocardial perfusion at rest to presenting clinical syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.A.; Okada, R.D.; Boucher, C.A.; Phillips, H.R.; Strauss, H.W.; Pohost, G.M.

    1983-07-01

    In order to determine whether there are differences in myocardial perfusion at rest among patients with various unstable and stable angina syndromes, serial thallium-201 imaging was performed at rest in 19 patients presenting with rapidly worsening exertional angina (unstable angina, group A), 12 patients with rest angina alone without exertional symptoms (unstable angina, group B), and 34 patients with chronic stable angina. No patient had an episode of angina within 4 hours of study. Nineteen of 19 (100%) patients in group A demonstrated transient defects compared to only 3 of 12 (25%) patients in group B (p less than 0.0001) and 4 of 34 (12%) stable angina patients (p less than 0.0001). The majority of zones demonstrating transient defects in group A were associated with hypokinesis of the corresponding left ventriculogram segment without associated ECG evidence of previous infarction. There were no significant differences in the frequency of persistent thallium defects, severity of angiographic coronary artery disease, or frequency of regional wall motion abnormalities of myocardial segments supplied by stenotic coronary arteries among the three groups of patients. Transient defects have been shown to reflect reduction in regional coronary blood flow to viable myocardium. Therefore, we conclude that regional resting hypoperfusion of viable myocardium is far more common in patients with exertional unstable angina symptoms than in patients with rest angina alone or chronic stable angina.

  6. Syndrome of diminished vasodilator reserve of the coronary microcirculation (microvascular angina or syndrome X): Diagnosis by combined atrial pacing and thallium 201 imaging--a case report

    Energy Technology Data Exchange (ETDEWEB)

    Magarian, G.J.; Palac, R.; Reinhart, S. (Veterans Administration Medical Center, Portland, OR (USA))

    1990-08-01

    Patients with angina-like chest pain without evidence of epicardial coronary artery disease or coronary arterial vasospasm are becoming increasingly recognized. These are often related to noncardiac causes including esophageal, musculoskeletal, and hyperventilatory or panic states. However, recently a subgroup of such patients are being recognized as having true myocardial ischemia and chest pain on the basis of diminished coronary microvascular vasodilatory reserve (microvascular ischemia or Syndrome X). The authors describe such a patient who was found to have replication of anginal pain associated with a reversible ischemic defect on thallium 201 imaging during atrial pacing, suggesting ischemia in this myocardial segment. Resolution of angina and ST segment electrocardiographic changes of ischemia occurred with cessation of pacing. We believe this is the first report of a patient with this form of myocardial ischemia diagnosed by this method and should be considered in patients with anginal chest pain after significant coronary artery disease and coronary vasospasm have been excluded.

  7. Determination of perfusion defect area in experimental myocardial infarction. A comparison between 201-thallium and sup 99m Tc methoxy-isobutyl-isonitril (MIBI)

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, K.D.; Rohmann, S.; Bahavar, H.; Grebe, S.F.; Schaper, W.; Schlepper, M. (Kerckhoff-Klinik, Bad Nauheim (Germany))

    1991-08-01

    To assess the accuracy of two myocardial perfusion markers in quantifying defect size, the left anterior descending coronary artery (LAD) was occluded in 13 porcine hearts. Fourty minutes later 55 MBq {sup 201}TI and 370 MBq {sup 99m}Tc-MIBI were simultaneously injected i.v. in 10 animals. After injection and in vivo double nuclide SPECT acquisition, the risk area was demarcated with fluorescein (FI) dye in 5 animals. The in vitro defect area determined by {sup 201}TI was significant larger (15.8 {+-} 27%) than those of {sup 99m}Tc-MIBI, while FI compared to Tc showed no statistical difference. Thus, in a pig model Tc-MIBI was more accurate with ex vivo imaging. With SPECT thallium imaging defect size was overestimated. In vivo there was a distinct trend with Tc-MIBI studies to underestimate the defect size up to 16%. (orig.).

  8. High thallium content in rocks associated with Au-As-Hg-Tl and coal mineralization and its adverse environmental potential in SW Guizhou, China

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, T.F.; Guha, J.; Boyle, D. [Chinese Academy of Science, Guiyang (China)

    2004-08-15

    This study is focused on high concentrations of Tl in rocks in SW Guizhou, China, that are related to several widely scattered disseminated gold-mercury-arsenic and coal deposits, and a primary Tl deposit within an Au-As-Hg-Tl metallogenic belt of the Huijiabao anticline. The Tl, Hg and As in the Lanmuchang Hg-Tl deposit area are associated with the abundant occurrence of sulfide minerals such as lorandite, realgar, orpiment and cinnabar. Concentrations of Tl range from 100 to 35 000 ppm in sulfide ores, and 39-490 ppm in host rocks. The enrichment of Au, Tl, Hg, As, and Sb in the Yanshang gold mineralized area reflects the occurrence of Au mineralization and its mineral assemblage of Tl-Hg-As-Sb sulfides. Thallium ranges from 0.22 to 16 ppm in Au ores and host rocks. Thallium in coals is enriched up to 46 ppm within the Au-As-Hg-TI metallogenic belt, and is derived from the regional Au-As-Hg-Tl mineralization. Mercury and As show a similar distribution to Tl with high concentrations in sulfide ores, coals and host rocks. Human populations living near and downstream of Tl deposits and Tl-bearing ore deposits are susceptible to Tl contamination because of its high toxicity and high uptake rate by crops. The dispersion of Tl, Hg and As associated with the primary mineralization of Au-As-Hg-TI can be traced through physical erosion and chemical weathering, producing secondary dispersion into sods, groundwater and surface water and crops. Mining activities compound the natural processes, readily dispersing Tl into the surface environment.

  9. Functional significance of myocardial perfusion defects induced by dipyridamole using thallium-201 single-photon emission computed tomography and two-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Jain, A.; Suarez, J.; Mahmarian, J.J.; Zoghbi, W.A.; Quinones, M.A.; Verani, M.S. (Baylor College of Medicine, Houston, TX (USA))

    1990-10-01

    The mechanisms responsible for inhomogeneous myocardial blood flow after oral administration of a large dose (300 mg) of dipyridamole were assessed in 27 patients with serial thallium-201 single-photon emission computed tomography (SPECT) and simultaneous 2-dimensional echocardiograms. Myocardial tomographic images were obtained 50 minutes and 3 to 4 hours after administration of dipyridamole. Two-dimensional echocardiograms were recorded at baseline and then every 15 minutes for 60 minutes. Dipyridamole caused only a mild reduction in blood pressure (from 129 +/- 18 to 126 +/- 16 mm Hg) and a mild increase in heart rate (from 69 +/- 15 to 73 +/- 4 beats/min). Sixteen patients had perfusion defects after dipyridamole by SPECT, which underwent partial or total filling-in. Fourteen of these patients (87.5%) had either a new abnormality or further deterioration of a preexisting wall motion abnormality by 2-dimensional echocardiography, and thus were considered to have developed transient ischemia during dipyridamole administration. Ten of 11 patients (91%) with normal perfusion or fixed defects by SPECT had no further deterioration in wall motion after oral dipyridamole, and were thus considered to have no evidence of myocardial ischemia. In conclusion, most patients with transient thallium-201 defects after dipyridamole develop transient worsening of resting wall motion by 2-dimensional echocardiography, suggestive of true myocardial ischemia. Because myocardial oxygen demand, as indicated by the heart rate-blood pressure product, did not change significantly, the mechanism of myocardial ischemia in these patients is likely to be diminished regional blood flow related to a subendocardial steal induced by dipyridamole.

  10. Effects of Potassium-Channel Opener on Thallium-201 Kinetics: In-vitro Study in Rat Myocyte Preparations and In-vivo Mice Biodistribution Study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Tae; Kim, Eun Ji; Ahn, Byeong Cheol; Son, Kang Kyun; Lee, Kyu Bo [Kyungpook National University School of Medicine, Taegu (Korea, Republic of); Ha, Jeoung Hee [Youngnam University Medical School, Taegu (Korea, Republic of); Kim, Chun Ki [Mt. Sinai School of Medicine, New York (United States)

    1996-10-15

    Potassium channel opener (K-opener) opens ATP-sensitive K{sup +}-channel located at membrane and induces potassium efflux from cytosol, resulting in intracellular hyperpolarization. Newly synthesized K-opener is currently examined for pharmacologic potency by means of rubidium release test from smooth muscle strip preincubated with Rb-86. Since in-vive behavior of thallium is similar to that of rubidium, we hypothesized that K-opener can alter T1-201 kinetics in vivo. This study was prepared to investigate the effects of pinacidil (one of potent K-openers) on the T1-201 uptake and clearance in cultured myocyte, and in-vivo biodistribution in mice. Spontaneous contracting myocytes were prepared to imitate in-vivo condition from 20 hearts of 3-5 days old Sprague-Dawley rat and cultured for 3-5 days before use (5 X 105 cells/ml). Pinacidil was dissolved in 10% DMSO solution at a final concentration of 100nM or 10uM and was co-incubated with T1-201 in HBSS buffer for 20-min to evaluate its effect on cellular T1-uptake, or challenged to cell preparation pre-incubated with T1-201 for washout study. Two, 40 or 100 mg of pinacidil was injected intravenously into ICR mice at 10 min after 5 muCi T1-201 injection, and organ uptake and whole body retention rate were measured at different time points. Co-incubation of pinacidil with T1-201 resulted in a decrease in T1-201 uptake into cultured myocyte by 1.6 to 2.5 times, depending on pinacidil concentration and activity of T1-201 used. Pinacidil enhanced T1-201 washout by 1.6-3.1 times from myocyte preparations pre-incubated with T1-201. Pinacidil treatment appears to be resulted in mild decreases in blood and liver activity in normal mice, in contrast, renal and cardiac uptake were mildly decreased in a dose dependent manner. Whole body retention ratios of T1-201 were lower at 24 hour after injection with 100 mg of pinacidil than control. These results suggest that treatment with K-opener may affect the interpretation of T1

  11. From lattice ion ion-exchanger to ion memorizing ion-exchanger; Koshi ion ion kokantai kara ion kioku ion kokantai e

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, T. [Yamanashi University, Yamanashi (Japan). Faculty of Engineering

    1996-05-05

    Introduced in this report is the lattice-ion ion exchanger and ion-memorizing ion exchanger that have of late developed into key words. The former is the name given to inorganic ion exchangers, such as hydroxyapatite (hereinafter to be shortened to HAp), which selectively exchange ions for other ions in a water solution, at the ordinary temperature and atmospheric pressure off the common knowledge in inorganic structural chemistry. HAp is an example different from the conventional counter-ion ion exchangers as represented by zeolite, in terms of the order of selectiveness it demonstrates when encountering various cations. HAp and the same with its PO4{sup 3-} ion group replaced with a CO3{sup 2-} or SiO4{sup 4-} group is effective in removing dangerous ions and in sterilizing. The ion-memorizing ion exchanger is a development from the lattice-ion ion exchanger, and is capable of very selectively collecting and removing specified ions as if it remembered the specified ions. The Li- or K-ion-memorizing ion exchanger is a typical example. 17 refs., 4 figs, 4 tabs.

  12. Determination of particle mass deposition according to Bergerhoff; Performance characteristics of the measurement of particle mass deposition and its portions of lead, cadmium, zinc and thallium. Bestimmung des Staubniederschlags nach Bergerhoff; Verfahrenskenngroessen fuer die Messung des Staubniederschlags und seiner Anteile an Blei, Cadmium, Zink und Thallium

    Energy Technology Data Exchange (ETDEWEB)

    Gehrig, R. (Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland). Abt. fuer Luftfremdstoffe); Faesi, C. (Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland). Abt. fuer Luftfremdstoffe); Hofer, P. (Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland). Abt. fuer Luftfremdstoffe)

    1993-05-01

    The requirements concerning quality assurance have increased considerably in the field of immission control. Well founded values for detection limits and confidence limits have to be given. Based on the statistical analysis of long term data series of deposition measurements of particle mass (Berghoff method), lead, cadmium, zinc and thallium performance characteristics were established for very differently polluted sites. The resulting detection limits as well as confidence limits are low enough for a reliable control of the respective immission limit values. It is further shown that the use of plastic buckets instead of the glass buckets required by the VDI guideline or the addition of a protecting agent to avoid freezing does not affect the measurements significantly. (orig.)

  13. ION VATAMANU

    Directory of Open Access Journals (Sweden)

    l. Povar

    2012-12-01

    Full Text Available Ion Vatamanu was a chemist, writer and public figure. He was equally passionate about both his chosen fields of activity: chemistry and poetry. Chemistry, with its perfect equilibrium of logic and precision, provided inspiration for lyrical creativity, whereas poetry writing enlivened his imagination and passion for chemistry. He loved his parents. He adored his wife Elena, whom he often gifted a sea of flowers. He loved his daughters Mihaela, Mariana, and Leontina. He loved life, and he loved people.

  14. Ion Beam Extraction by Discrete Ion Focusing

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (900) and methods are disclosed for ion beam extraction. In an implementation, the apparatus includes a plasma source (or plasma) (802) and an ion extractor (804). The plasma source is adapted to generate ions and the ion extractor is immersed in the plasma source to extract a fraction...... of the generated ions. The ion extractor is surrounded by a space charge (810) formed at least in part by the extracted ions. The ion extractor includes a biased electrode (806) forming an interface with an insulator (808). The interface is customized to form a strongly curved potential distribution (812......) in the space-charge surrounding the ion extractor. The strongly curved potential distribution focuses the extracted ions towards an opening (814) on a surface of the biased electrode thereby resulting in an ion beam....

  15. Replacement of a photomultiplier tube in a 2-inch thallium-doped sodium iodide gamma spectrometer with silicon photomultipliers and a light guide

    Directory of Open Access Journals (Sweden)

    Chankyu Kim

    2015-06-01

    Full Text Available The thallium-doped sodium iodide [NaI(Tl] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs. It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl 2′ × 2′ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

  16. Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: a comparative dual-isotope study.

    Science.gov (United States)

    Zimmermann, R; Rauch, B; Kapp, M; Bubeck, B; Neumann, F J; Seitz, F; Stokstad, P; Mall, G; Tillmanns, H; Kübler, W

    1992-01-01

    To characterise the clinical usefulness of serial myocardial scintigraphy with iodine-123 phenylpentadecanoic acid (IPPA) in comparison with thallium-201, dual-isotope investigations were performed in 41 patients with angiographically documented coronary artery disease. Both tracers were administered simultaneously during symptom-limited ergometry. Planar scintigrams were acquired immediately after stress, and delayed imaging was performed after 1 h for IPPA and 4 h for 201Tl. Scintigrams were evaluated both qualitatively and quantitatively using a newly developed algorithm for automated image superposition. Initial myocardial uptake of both tracers was closely correlated (r = 0.75, p or = 75% (IP-PA: 70.0%, 201Tl: 66.3%, P = NS) with identical specificity (69.8%). The number of persistent defects, however, was significantly higher with IPPA (P = 0.021), suggesting that visual analysis of serial IPPA scintigrams may overestimate the presence of myocardial scar tissue. On the other hand, previous Q wave myocardial infarction was associated with a decreased regional IPPA clearance (29% +/- 11% vs 44% +/- 11% in normal myocardium, P IPPA is essentially as sensitive as scintigraphy with 201Tl for the detection of stress-induced perfusion abnormalities. Quantitative analysis of myocardial IPPA kinetics, however, is required for the evaluation of tissue viability.

  17. Dynamic low dose I-123-iodophenylpentadecanoic acid metabolic cardiac imaging; Comparison to myocardial biopsy and reinjection SPECT thallium in ischemic cardiomyopathy and cardiac transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Murray, G.L.; Magill, H.L. [Baptist Memorial Hospital (United States); Schad, N.C.

    1993-12-01

    Recognition of stunned and hibernating myocardium is essential in this era of cardiac revascularization. Positron emission tomography (PET) accurately identifies viability but is costly and unavailable to most patients. Dynamic low dose I-123-iodophenylpentadecanoic acid (IPPA) metabolic cardiac imaging is a potentially cost-effective alternative to PET. Using transmural myocardial biopsies obtained during coronary bypass surgery as the viability gold standard, resting IPPA imaging agreed with 39/43 (91%) biopsies, with a sensitivity for viability of 33/36(92%) and a specificity of 6/7 (86%) in patients with severe ischemic cardiomyopathy. Eighty percent of IPPA viable, infarcted segments improved wall motion postoperatively. Furthermore, when compared to reinjection thallium (SPECT-Tl) scans after myocardial infarction, there was IPPA-Tl concordance in 27/35 (77%)(Kappa=0.536, p=0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-Tl, 26/35 (74%) vs. 18/35 (51%)(p=0.047). Finally, when compared to transvenous endomyocardial biopsy for detecting rejection following cardiac transplantation, IPPA sensitivity for {>=}Grade II rejection was 100%, and IPPA screening assessment for the necessity of biopsy could result in a 31% cost-savings. Therefore, IPPA metabolic cardiac imaging is a safe, inexpensive technique with a promising future. (author).

  18. Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: A comparative dual-isotope study

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, R.; Rauch, B.; Kapp, M.; Neumann, F.J.; Seitz, F.; Kuebler, W. (Heidelberg Univ. (Germany). Dept. of Cardiology); Bubeck, B. (Heidelberg Univ. (Germany). Dept. of Nuclear Medicine); Mall, G. (Heidelberg Univ. (Germany). Dept. of Pathology); Tillmanns, H. (Giessen Univ. (Germany). Dept. of Cardiology); Stokstad, P.

    1992-11-01

    To characterise the clinical usefulness of serial myocardial scintigraphy with iodine-123 phenylpentadecanoic acid (IPPA) in comparison with thallium-201, dual-isotope investigations were performed in 41 patients with angiographically documented coronary artery disease. Both tracers were adminstered simultaneously during symptom-limited ergometry. Planar scintigrams were acquired immediately after stress, and delayed imaging was performed after 1 h for IPPA and 4 h for {sup 201}Tl. Scintigrams were evaluated both qualitatively and quantitatively using a newly developed algorithm for automated image superposition. Initial myocardial uptake of both tracers was closely correlated (r=0.75, p<0.001). Both tracers also revealed a similar sensitivity for the identification of individual coronary artery stenoses {>=}75% (IPPA: 70%, {sup 201}Tl: 66.3%, P=NS) with identical specificity (69.8%). The number of persistent defects, however, was significantly higher with IPPA (P=0.021), suggesting that visual analysis of serial IPPA scintigrams may overestimate the presence of myocardial scar tissue. On the other hand, previous Q wave myocardial infarction was associated with a decreased regional IPPA clearance (29%{+-}11% vs 44%{+-}11% in normal myocardium, P<0.05). The data indicate that serial myocardial scintigraphy with IPPA is essentially as sensitive as scintigraphy with {sup 201}Tl for the detection of stress-induced perfusion abnormalities. Quantitative analysis of myocardial IPPA kinetics, however, is required for the evaluation of tissue viability. (orig.).

  19. Myocardial viability assessment with dynamic low-dose iodine-123-iodophenylpentadecanoic acid metabolic imaging: comparison with myocardial biopsy and reinjection SPECT thallium after myocardial infarction.

    Science.gov (United States)

    Murray, G L; Schad, N C; Magill, H L; Vander Zwaag, R

    1994-04-01

    Aggressive cardiac revascularization requires recognition of stunned and hibernating myocardium, and cost considerations may well govern the technique used. Dynamic low-dose (1 mCi) [123I]iodophenylpentadecanoic acid (IPPA) metabolic imaging is a potential alternative to PET using either 18FDG or 15O-water. Resting IPPA images were obtained from patients with severe ischemic cardiomyopathy, and transmural myocardial biopsies were obtained during coronary bypass surgery to confirm viability. Thirty-nine of 43 (91%) biopsies confirmed the results of the IPPA images with a sensitivity for viability of 33/36 (92%) and a specificity of 6/7 (86%). Postoperatively, wall motion improved in 80% of IPPA-viable, dysfunctional segments. Furthermore, when compared to reinjection thallium (SPECT-TI) scans after myocardial infarction, IPPA-SPECT-TI concordance occurred in 27/35 (77%) (K = 0.536, p = 0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-TI, 26/35 (74%) versus 18/35 (51%) (p = 0.047). Metabolic IPPA cardiac viability imaging is a safe, inexpensive technique that may be a useful alternative to PET.

  20. Identification and Decay Studies of New, Neutron-Rich Isotopes of Bismuth, Lead and Thallium by means of a Pulsed Release Element Selective Method

    CERN Multimedia

    Mills, A; Kugler, E; Van duppen, P L E; Lettry, J

    2002-01-01

    % IS354 \\\\ \\\\ It is proposed to produce, identify and investigate at ISOLDE new, neutron-rich isotopes of bismuth, lead and thallium at the mass numbers A=215 to A=218. A recently tested operation mode of the PS Booster-ISOLDE complex, taking an advantage of the unique pulsed proton beam structure, will be used together with a ThC target in order to increase the selectivity. The decay properties of new nuclides will be studied by means of $\\beta$-, $\\gamma$- and X- ray spectroscopy methods. The expected information on the $\\beta$-half-lives and excited states will be used for testing and developing the nuclear structure models ``south-east'' of $^{208}$Pb, and will provide input data for the description of the r-process path at very heavy nuclei. The proposed study of the yields and the decay properties of those heavy nuclei produced in the spallation of $^{232}$Th by a 1~GeV proton beam contributes also the data necessary for the simulations of a hybrid accelerator-reactor system.

  1. Thallium contamination in arable soils and vegetables around a steel plant-A newly-found significant source of Tl pollution in South China.

    Science.gov (United States)

    Liu, Juan; Luo, Xuwen; Wang, Jin; Xiao, Tangfu; Chen, Diyun; Sheng, Guodong; Yin, Meiling; Lippold, Holger; Wang, Chunlin; Chen, Yongheng

    2017-05-01

    Thallium (Tl) is a highly toxic rare element. Severe Tl poisoning can cause neurological brain damage or even death. The present study was designed to investigate contents of Tl and other associated heavy metals in arable soils and twelve common vegetables cultivated around a steel plant in South China, a newly-found initiator of Tl pollution. Potential health risks of these metals to exposed population via consumption of vegetables were examined by calculating hazard quotients (HQ). The soils showed a significant contamination with Tl at a mean concentration of 1.34 mg/kg. The Tl levels in most vegetables (such as leaf lettuce, chard and pak choy) surpassed the maximum permissible level (0.5 mg/kg) according to the environmental quality standards for food in Germany. Vegetables like leaf lettuce, chard, pak choy, romaine lettuce and Indian beans all exhibited bioconcentration factors (BCF) and transfer factors (TF) for Tl higher than 1, indicating a hyperaccumulation of Tl in these plants. Although the elevated Tl levels in the vegetables at present will not immediately pose significant non-carcinogenic health risks to residents, it highlights the necessity of a permanent monitoring of Tl contamination in the steel-making areas. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Thallium-201 is comparable to technetium-99m-sestamibi for estimating cardiac function in patients with abnormal myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Ming-Che Wu

    2015-11-01

    Full Text Available We analyzed the left-ventricular functional data obtained by cardiac-gated single-photon emission computed tomography myocardial perfusion imaging (MPI with thallium-201 (Tl-201 and technetium-99m-sestamibi (MIBI protocols in different groups of patients, and compared the data between Tl-201 and MIBI. Two hundred and seventy-two patients undergoing dipyridamole stress/redistribution Tl-201 MPI and 563 patients undergoing 1-day rest/dipyridamole stress MIBI MPI were included. Higher mean stress ejection fraction (EF, rest EF, and change in EF (ΔEF were noticed in the normal MPI groups by both Tl-201 and MIBI protocols. Higher mean EF was observed in the females with normal MPI results despite their higher mean age. Comparisons between the Tl-201 and MIBI groups suggested a significant difference in all functional parameters, except for the rest end diastolic volume/end systolic volume and ΔEF between groups with negative MPI results. For the positive MPI groups, there was no significant difference in all parameters, except for the change in end diastolic volume and change in end systolic volume after stress between both protocols. The Tl-201 provides comparable left-ventricular functional data to MIBI cardiac-gated single-photon emission computed tomography in patients with positive MPI results, and may therefore be undertaken routinely for incremental functional information that is especially valuable to this patient group.

  3. Usefulness of thallium-201 myocardial scintigraphy during hyperventilation and accelerated exercise test in patients with vasospastic angina and nearly normal coronary artery

    Energy Technology Data Exchange (ETDEWEB)

    Sueda, Shozo; Mineoi, Kazuaki; Kondou, Tadashi [Takanoko Hospital, Matsuyama, Ehime (Japan)] [and others

    1998-04-01

    The usefulness of thallium-201 ({sup 201}Tl) myocardial scintigraphy was studied in 109 patients with vasospastic angina who had nearly normal coronary arteries (degree of stenosis <50%). Coronary spasm was confirmed by pharmacologic agents in all 109 patients from January 1991 to June 1996. The appearance rate of visual redistribution on {sup 201}Tl myocardial scintigraphy was compared between four groups, 34 patients performing graded bicycle ergometer exercise starting at a work load of 50 W with increments of 25 W every 3 min (Ergo(3) group), 14 patients performing hyperventilation for 5 min (HV(5) group), 31 patients performing bicycle ergometer exercise with increments of 25 W every 1 min after 5 min hyperventilation (HV(5)+Ergo(1) group), and 30 patients at rest (Rest group). The value of the visual redistribution rate on {sup 201}Tl myocardial scintigrams in the HV(5)+Ergo(l) group (65%) was higher than that in the patients of other groups (Ergo(3) 41%, HV(5) 43%, Rest 33%). However, there were no significant differences between the four groups. Stress {sup 201}Tl imaging after hyperventilation and accelerated exercise is useful to disclose ischemic evidence in about two thirds of patients with vasospastic angina and nearly normal coronary arteries, whereas about 40% of patients had visual redistribution on {sup 201}Tl myocardial scintigrams by performing standard procedures. (author)

  4. On-line preconcentration of ultra-trace thallium(I in water samples with titanium dioxide nanoparticles and determination by graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Saeid Asadpour

    2016-11-01

    Full Text Available A new method has been developed for the determination of Tl(I based on simultaneous sorption and preconcentration with a microcolumn packed with TiO2 nanoparticle with a high specific surface area prepared by Sonochemical synthesis prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS. The optimum experimental parameters for preconcentration of thallium, such as elution condition, pH, and sample volume and flow rate have been investigated. Tl(I can be quantitatively retained by TiO2 nanoparticles at pH 9.0, then eluted completely with 1.0 mol L−1 HCl. The adsorption capacity of TiO2 nanoparticles for Tl(I was found to be 25 mg g−1. Also detection limit, precision (RSD, n = 8 and enrichment factor for Tl(I were 87 ng L−1, 6.4% and 100, respectively. The method has been applied for the determination of trace amounts of Tl(I in some environmental water samples with satisfactory results.

  5. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Sakata, Hitomi; Ishihara, Tadayuki

    2001-02-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ({sup 201}Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting {sup 201}Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by {sup 201}Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting {sup 201}Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  6. Studies on the adsorption of caesium, thallium, strontium and cobalt radionuclides on activated carbons from aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Rivera-Utrilla, J.; Ferro-Garcia, M.A.; Mata-Arjona, A.; Gonzalez-Gomez, C. (Granada Univ. (Spain). Dept. of Inorganic Chemistry)

    1984-07-01

    Individual adsorption studies of Cs/sup +/, Tl/sup +/, Sr/sup 2 +/ and Co/sup 2 +/ on activated carbons from aqueous solutions are reported. The carbon samples were characterised using different techniques. The surface area and the micro-, meso- and macropore volumes of all samples have been calculated. The chemical nature of the surface of the activated carbons was also studied. Optimal conditions for the adsorption of the metal ions have been identified. The adsorption of these cations by the carbon samples was also determined in the presence of a number of different anions. The data suggest the possible use of activated carbons for the preconcentration and separation of some cations.

  7. Iodine-123 phenylpentadecanoic acid and single photon emission computed tomography in identifying left ventricular regional metabolic abnormalities in patients with coronary heart disease: comparison with thallium-201 myocardial tomography.

    Science.gov (United States)

    Hansen, C L; Corbett, J R; Pippin, J J; Jansen, D E; Kulkarni, P V; Ugolini, V; Henderson, E; Akers, M; Buja, L M; Parkey, R W

    1988-07-01

    Iodine-123 phenylpentadecanoic acid (IPPA) is a synthetic long chain fatty acid with myocardial kinetics similar to palmitate. Two hypotheses were tested in this study. The first hypothesis was that IPPA imaging with single photon emission computed tomography (SPECT) is useful in the identification of patients with coronary artery disease. Fourteen normal volunteers (aged 27 +/- 2 years) and 33 patients (aged 54 +/- 11 years) with stable symptomatic coronary artery disease and at least one major coronary artery with luminal diameter narrowing greater than or equal to 70% were studied with symptom-limited maximal exercise testing. The IPPA (6 to 8 mCi) was injected 1 min before the termination of exercise, and tomographic imaging was performed beginning at 9 min and repeated at 40 min after the injection of IPPA. Nine of the normal volunteers and 13 of the patients had a second examination performed at rest on another day. Using the limits of normal as 2 SD from the normal mean values, 27 of the 33 patients with coronary artery disease demonstrated abnormalities in either the initial distribution or the clearance of IPPA, or both. Nineteen of the 33 patients had a maximal variation of activity distribution of greater than or equal to 25% on the 9 min IPPA images. Twenty-two of the 33 patients had a maximal variation in IPPA washout greater than 17% and 17 had a washout rate less than or equal to 2%. There was good agreement between the location of significant coronary artery stenoses and abnormalities in the initial distribution and clearance of IPPA. The second hypothesis tested was that IPPA imaging is as or more sensitive and, therefore, complementary to thallium-201 imaging in the identification of exercise-induced ischemia in patients. Twenty-five of the 33 patients underwent both thallium-201 and IPPA tomographic imaging after symptom-limited maximal exercise testing. The amount of exercise performed by each patient during both studies was similar. Twenty

  8. Simultaneous dual myocardial imaging with iodine-123-[beta]-methyl iodophenyl-pentadecanoic acid (BMIPP) and thallium-201 in patients with coronary heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Tawarahara, Kei; Kurata, Chinori; Taguchi, Takahisa; Aoshima, Shigeyuki; Okayama, Kenichi; Kobayashi, Akira; Yamazaki, Noboru; Kaneko, Masao (Hamamatsu Univ. School of Medicine, Shizuoka (Japan))

    1994-02-01

    To assess the clinical value of simultaneous dual myocardial imaging with iodine-123-[beta]-methyl-iodophenyl-pentadecanoic acid ([sup 123]I-BMIPP) and thallium-201 ([sup 201]TL), myocardial imaging was performed at rest and during execise in seven patients with coronary heart disease. When [sup 123]I-BMIPP and [sup 201]Tl images were compared, the initial exercise and resting images agreed 87% and 64%, respectively. In the initial resting images, the regional uptake of [sup 123]I-BMIPP was frequently less than that of [sup 201]Tl. The incidence of exercise-induced reversible defects by [sup 201]Tl in the Tl>BMIPP regions was significantly higher than that in the Tl=BMIPP regions (57% vs 4%, p<0.01) and the incidence of coronary narrowing of more than 90% in the Tl>BMIPP regions was also significantly higher than that in the Tl=BMIPP regions (91% vs 38%, p<0.01). In addition, this disparity (Tl>BMIPP) was found more frequently in regions with abnormal wall motion than in regions with normal wall motion (hypokinetic regions; 68%, severe hypokinetic or akinetic regions; 50%, vs normokinetic regions; 4%, p<0.01). In contrast, the uptake of [sup 123]I-BMIPP correlated closely with that of [sup 201]Tl in normal myocardium and the uptake of both [sup 123]I-BMIPP and [sup 201]Tl was severely reduced in myocardium with severe ischemia during exercise and prior infarction. These results indicate that dual myocardial imaging with [sup 123]I-BMIPP and [sup 201]Tl may provide a unique means of identifying patients with metabolically disturbed myocardium, such as hibernating and stunned myocardium. (author).

  9. Imaging of brain tumors in AIDS patients by means of dual-isotope thallium-201 and technetium-99m sestamibi single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    De La Pena, R.C.; Ketonen, L.; Villanueva-Meyer, J. [Dept. of Radiology, Univ. of Texas, Galveston (United States)

    1998-10-01

    Our aim was to evaluate the use of dual-isotope thallium-201 (Tl) and technetium-99m sestamibi (sestamibi) simultaneous acquisition in brain single-photon emission tomography (SPET) for the differentiation between brain lymphoma and benign central nervous system (CNS) lesions in AIDS patients. Thirty-six consecutive patients with enhancing mass lesions on magnetic resonance (MR) imaging were included in the study. SPET of the brain was performed to obtain simultaneous Tl and sestamibi images. Regions-of-interest were drawn around the lesion and on the contralateral side to calculate uptake ratios. The final diagnosis was reached by pathologic findings in 17 patients and clinical and/or MR follow-up in 19 patients. Of the 36 patients, 11 had brain lymphoma, 1 glioblastoma multiforme, 15 toxoplasmosis and 9 other benign CNS lesions. Correlation between SPET and the final diagnosis revealed in 10 true-positive, 23 true-negative, 1 false-positive and 2 false-negative studies. All patients with toxoplasmosis had negative scans. A patient with a purulent infection had positive scans. Tl and sestamibi scans were concordant in every lesion. The same lesions that took up Tl were also visualized with sestamibi. However, sestamibi scans showed higher lesion-to-normal tissue uptake ratios (3.7{+-}1.8) compared with those of Tl (2.3{+-}0.8, P<0.002). Simultaneous acquisition of Tl and sestamibi can help differentiate CNS lymphoma from benign brain lesions in AIDS patients. (orig.) With 2 figs., 2 tabs., 34 refs.

  10. BaHg2Tl2. An unusual polar intermetallic phase with strong differentiation between the neighboring elements mercury and thallium.

    Science.gov (United States)

    Dai, Jing-Cao; Gupta, Shalabh; Gourdon, Olivier; Kim, Hyun-Jeong; Corbett, John D

    2009-06-24

    High yields of the novel BaHg(2)Tl(2) are achieved from reactions of the appropriate cast alloys at approximately 400 degrees C. (Isotypic SrHg(2)Tl(2) also exists.) The tetragonal barium structure (P4(2)/mnm, a = 10.606 A, c = 5.159 A) was refined from both single-crystal X-ray and neutron powder diffraction data in order to ensure the atom site assignments although distances and calculated atom site population also support the results. The Hg and Tl network atoms are distinctive in their functions and bonding. Parallel chains of Hg hexagons and of Tl tetrahedra along c are constructed from polyhedra that share opposed like edges, and these are in turn interconnected by Hg-Tl bonds. Overall, the number of Tl-Tl bonds per cell exceeds the Hg-Hg type by 20:12, but these are approximately 1:2 each in bonding according to their average -ICOHP values (related to overlap populations). Barium is bound within a close 15-atom polyhedron, 12 atoms of which are the more electronegative Hg. LMTO-ASA calculations show that scalar relativistic effects are particularly important for Hg 5d-6s mixing in Hg-Hg and Hg-Tl bonding, whereas relatively separate Tl 6s and 6p states are more important in Tl-Tl interactions. The 6p states of Hg and Tl and 5d of Ba define a dominant conduction band around E(F), and the phase is metallic and Pauli-like paramagnetic. The thallium characteristics here are close to those in numerous alkali-metal-Tl cluster systems. Other active metal-mercury phases that have been studied theoretically are all distinctly electron-richer and more reduced, and without appreciable net 5d, 6s contributions to Hg-Hg bonding.

  11. Gas phase ion chemistry

    CERN Document Server

    Bowers, Michael T

    1979-01-01

    Gas Phase Ion Chemistry, Volume 1 covers papers on the advances of gas phase ion chemistry. The book discusses the advances in flow tubes and the measurement of ion-molecule rate coefficients and product distributions; the ion chemistry of the earth's atmosphere; and the classical ion-molecule collision theory. The text also describes statistical methods in reaction dynamics; the state selection by photoion-photoelectron coincidence; and the effects of temperature and pressure in the kinetics of ion-molecule reactions. The energy distribution in the unimolecular decomposition of ions, as well

  12. Microfabricated ion frequency standard

    Science.gov (United States)

    Schwindt, Peter; Biedermann, Grant; Blain, Matthew G.; Stick, Daniel L.; Serkland, Darwin K.; Olsson, III, Roy H.

    2010-12-28

    A microfabricated ion frequency standard (i.e. an ion clock) is disclosed with a permanently-sealed vacuum package containing a source of ytterbium (Yb) ions and an octupole ion trap. The source of Yb ions is a micro-hotplate which generates Yb atoms which are then ionized by a ultraviolet light-emitting diode or a field-emission electron source. The octupole ion trap, which confines the Yb ions, is formed from suspended electrodes on a number of stacked-up substrates. A microwave source excites a ground-state transition frequency of the Yb ions, with a frequency-doubled vertical-external-cavity laser (VECSEL) then exciting the Yb ions up to an excited state to produce fluorescent light which is used to tune the microwave source to the ground-state transition frequency, with the microwave source providing a precise frequency output for the ion clock.

  13. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma.

    Science.gov (United States)

    Lin, J D; Kao, P F; Weng, H F; Lu, W T; Huang, M J

    1998-07-01

    Radioactive iodine (131I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. 201Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative 131I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of 201Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of 131I and 201Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative 201Tl and 131I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. 201Tl imaging was performed before the 131I studies. Of the 62 patients who underwent 201Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the 201Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic 131I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by 201Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative 201Tl scans, 11 had positive findings on 131I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on 131I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative 201Tl and 131I scans, 15 had elevated serum Tg levels. Among these, local recurrence followed by lung metastases was manifested in

  14. MRI and thallium features of pigmented villonodular synovitis and giant cell tumours of tendon sheaths: a retrospective single centre study of imaging and literature review.

    Science.gov (United States)

    Lynskey, Samuel J; Pianta, Marcus J

    2015-01-01

    The purpose of this study was to characterize the MRI and thallium-201 ((201)TI) scintigraphy attributes of pigmented villonodular synovitis (PVNS) and giant cell tumours of tendon sheaths (GCTTS). The epidemiology of these uncommon lesions was also assessed and less commonly encountered pathology reported on including multifocality, necrosis and concurrent malignancy. A retrospective single centre review of MRI and (201)TI scintigraphy findings for 83 surgically proven or biopsy-proven consecutive cases of PVNS was undertaken. Radiological findings including lesion size, (201)TI uptake (as a marker of metabolic activity), location, extent and patient demographics were correlated with biopsy and surgical specimen histology. Typical appearances are described, as well as less common imaging manifestations. The study period encompassed all patients presenting or referred to a tertiary bone and soft-tissue tumour referral centre with PVNS or GCTTS between 1 January 2007 and the 1 December 2013. Lesions occur most commonly around the knee joint in the fourth decade of life, with younger patients showing a tendency to occur in the hip. Features of PVNS and GTTS include bone erosion, ligamentous and cartilage replacement, muscle infiltration and multifocality. MR signal characteristics were variable but post-contrast enhancement was near-universal. 14 of 83 cases showed no uptake of (201)TI and revealed a statistically significant smaller average axial dimension of 19.8 mm than lesions displaying active (201)TI uptake of 36.4 mm, p = 0.016. Four lesions demonstrated central necrosis on gross histology, two of each from both the (201)TI-avid and (201)TI-non-avid groups. MR is the imaging modality of choice when considering the diagnosis of these uncommon tumours. (201)TI scintigraphy as a marker of metabolic activity further adds minimal value although small lesions can appear to lack (201)TI avidity. This article depicts typical imaging findings of PVNS/GCTTS and

  15. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jen-Der; Weng Hsiao-Fen; Lu Wen-Tsoung [Division of Endocrinology and Metabolism, Chang Gung Memorial Hospital (Taiwan, Province of China); Kao Pan-Fu; Huang Miau-Ju [Department of Nuclear Medicine, Chang Gung Memorial Hospital, Taiwan (Taiwan, Province of China)

    1998-07-01

    Radioactive iodine ({sup 131}I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. {sup 201}Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative {sup 131}I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of {sup 201}Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of {sup 131}I and {sup 201}Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative {sup 201}Tl and {sup 131}I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. {sup 201}Tl imaging was performed before the {sup 131}I studies. Of the 62 patients who underwent {sup 201}Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the {sup 201}Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic {sup 131}I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by {sup 201}Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative {sup 201}Tl scans, 11 had positive findings on {sup 131}I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on {sup 131}I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative {sup 201}Tl and {sup 131}I

  16. Effects of adenosine and a selective A2A adenosine receptor agonist on hemodynamic and thallium-201 and technetium-99m-sestaMIBI biodistribution and kinetics.

    Science.gov (United States)

    Mekkaoui, Choukri; Jadbabaie, Farid; Dione, Donald P; Meoli, David F; Purushothaman, Kailasnath; Belardinelli, Luiz; Sinusas, Albert J

    2009-10-01

    The purpose of this study was to compare a selective A(2A) adenosine receptor agonist (regadenoson) with adenosine in clinically relevant canine models with regard to effects on hemodynamics and thallium-201 ((201)Tl) and technetium-99m ((99m)Tc)-sestaMIBI biodistribution and kinetics. The clinical application of vasodilator stress for perfusion imaging requires consideration of the effects of these vasodilating agents on systemic hemodynamics, coronary flow, and radiotracer uptake and clearance kinetics. Sequential imaging and arterial blood sampling was performed on control, anesthetized closed-chest canines (n = 7) to evaluate radiotracer biodistribution and kinetics after either a bolus administration of regadenoson (2.5 microg/kg) or 4.5-min infusion of adenosine (280 microg/kg). The effects of regadenoson on coronary flow and myocardial radiotracer uptake were then evaluated in an open-chest canine model of a critical stenosis (n = 7). Results from ex vivo single-photon emission computed tomography were compared with tissue well-counting. The use of regadenoson compared favorably with adenosine in regard to the duration and magnitude of the hemodynamic effects and the effect on (201)Tl and (99m)Tc-sestaMIBI biodistribution and kinetics. The arterial blood clearance half-time was significantly faster for (99m)Tc-sestaMIBI (regadenoson: 1.4 +/- 0.03 min; adenosine: 1.5 +/- 0.08 min) than for (201)Tl (regadenoson: 2.5 +/- 0.16 min, p adenosine: 2.7 +/- 0.04 min, p regadenoson stress was significantly greater than the relative perfusion defect with (99m)Tc-sestaMIBI (0.69 +/- 0.03%, p regadenoson produced a hyperemic response comparable to a standard infusion of adenosine. The biodistribution and clearance of both (201)Tl and (99m)Tc-sestaMIBI during regadenoson were similar to adenosine vasodilation. Ex vivo perfusion images under the most ideal conditions permitted detection of a critical stenosis, although (201)Tl offered significant advantages over (99m

  17. Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters.

    Science.gov (United States)

    Kurisu, Satoshi; Sumimoto, Yoji; Ikenaga, Hiroki; Watanabe, Noriaki; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-07-01

    The myocardial perfusion single photon emission computed tomography synchronized with the electrocardiogram (gated SPECT) has been widely used for the assessment of left ventricular (LV) systolic and diastolic functions using Quantitative gated SPECT. The aim of this study was to compare the effects of 8-frame and 16-frame thallium-201 (Tl-201) gated SPECT for determining LV systolic and diastolic parameters. The study population included 42 patients with suspected coronary artery disease who underwent gated SPECT by clinical indication. LV systolic and diastolic parameters were assessed on 8-frame and 16-frame gated SPECT. There were good correlations in end-diastolic volume (r = 0.99, p < 0.001), end-systolic volume (ESV) (r = 0.97, p < 0.001) and ejection fraction (EF) (r = 0.95, p < 0.001) between 8-frame and 16-frame gated SPECT. Bland-Altman plot showed a significant negative slope of -0.08 in EDV indicating a larger difference for larger EDV. Eight-frame gated SPECT overestimated ESV by 2.3 ml, and underestimated EF by -4.2% than 16-frame gated SPECT. There were good correlations in peak filling rate (PFR) (r = 0.87, p < 0.001), one third mean filling rate (r = 0.87, p < 0.001) and time to PFR (r = 0.61, p < 0.001) between 8-frame and 16-frame gated SPECT. Eight-frame gated SPECT underestimated PFR by -0.22 than 16-frame gated SPECT. Eight-frame gated SPECT estimated as much MFR/3 and TPFR as 16-frame gated SPECT. According to the data, the study suggested that 8-frame Tl-201 gated SPECT could underestimate systolic and/or diastolic parameter when compared with 16-frame gated SPECT.

  18. Radioactive Ion Sources

    OpenAIRE

    Stora, T

    2014-01-01

    This chapter provides an overview of the basic requirements for ion sources designed and operated in radioactive ion beam facilities. The facilities where these sources are operated exploit the isotope separation online (ISOL) technique, in which a target is combined with an ion source to maximize the secondary beam intensity and chemical element selectivity. Three main classes of sources are operated, namely surface-type ion sources, arc discharge-type ion sources, and finally radio-frequenc...

  19. Ion recombination correction in carbon ion beams.

    Science.gov (United States)

    Rossomme, S; Hopfgartner, J; Lee, N D; Delor, A; Thomas, R A S; Romano, F; Fukumura, A; Vynckier, S; Palmans, H

    2016-07-01

    In this work, ion recombination is studied as a function of energy and depth in carbon ion beams. Measurements were performed in three different passively scattered carbon ion beams with energies of 62 MeV/n, 135 MeV/n, and 290 MeV/n using various types of plane-parallel ionization chambers. Experimental results were compared with two analytical models for initial recombination. One model is generally used for photon beams and the other model, developed by Jaffé, takes into account the ionization density along the ion track. An investigation was carried out to ascertain the effect on the ion recombination correction with varying ionization chamber orientation with respect to the direction of the ion tracks. The variation of the ion recombination correction factors as a function of depth was studied for a Markus ionization chamber in the 62 MeV/n nonmodulated carbon ion beam. This variation can be related to the depth distribution of linear energy transfer. Results show that the theory for photon beams is not applicable to carbon ion beams. On the other hand, by optimizing the value of the ionization density and the initial mean-square radius, good agreement is found between Jaffé's theory and the experimental results. As predicted by Jaffé's theory, the results confirm that ion recombination corrections strongly decrease with an increasing angle between the ion tracks and the electric field lines. For the Markus ionization chamber, the variation of the ion recombination correction factor with depth was modeled adequately by a sigmoid function, which is approximately constant in the plateau and strongly increasing in the Bragg peak region to values of up to 1.06. Except in the distal edge region, all experimental results are accurately described by Jaffé's theory. Experimental results confirm that ion recombination in the investigated carbon ion beams is dominated by initial recombination. Ion recombination corrections are found to be significant and cannot be

  20. Ions and light

    CERN Document Server

    Bowers, Michael T

    2013-01-01

    Gas Phase Ion Chemistry, Volume 3: Ions and Light discusses how ions are formed by electron impact, ion-molecule reactions, or electrical discharge. This book discusses the use of light emitted by excited molecules to characterize either the chemistry that formed the excited ion, the structure of the excited ion, or both.Organized into 10 chapters, this volume begins with an overview of the extension of the classical flowing afterglow technique to include infrared and chemiluminescence and laser-induced fluorescence detection. This text then examines the experiments involving molecules that ar

  1. Radioactive Ion Sources

    CERN Document Server

    Stora, T

    2013-01-01

    This chapter provides an overview of the basic requirements for ion sources designed and operated in radioactive ion beam facilities. The facilities where these sources are operated exploit the isotope separation online (ISOL) technique, in which a target is combined with an ion source to maximize the secondary beam intensity and chemical element selectivity. Three main classes of sources are operated, namely surface-type ion sources, arc discharge-type ion sources, and finally radio-frequency-heated plasma-type ion sources.

  2. IBC - ION BEAM CENTER

    Directory of Open Access Journals (Sweden)

    Johannes von Borany

    2017-12-01

    Full Text Available In the Ion Beam Center (IBC, various set-ups – electrostatic accelerators, ion implanters, plasma-based ion implantation equipment, low-energy ion tools, an ion microscope etc. – are combined into a unique facility for research and applications using ion beams. Almost all ions from stable chemical nuclides are available in the ion energy range from 10 eV to about 60 MeV. In addition to broad beams, also focused (down to 1 nm and highly-charged (charge state up to 45+ ion beams, or ions extracted from a plasma can be provided. In total, the IBC operates more than 30 dedicated tools or beamline end-stations. The specific expertise of IBC is the modification and analysis of solids by energetic ions aimed to develop novel materials for information technology, electronics or energy systems. In addition, ion beam analysis techniques became of increasing importance for interdisciplinary fields like geochemistry, climate or environmental research and resources technology. Special add-on services offered ensure a successful realization of user experiments. Based on a long-term expertise, specific equipment and common commercial procedures, the IBC is strongly active in the use of ion beam techniques for industrial applications aimed to initiate valuable product innovation.

  3. Yield and excitation function measurements of some nuclear reactions on natural thallium induced by protons leading to the production of medical radioisotopes {sup 201}Tl and {sup 203}Pb

    Energy Technology Data Exchange (ETDEWEB)

    Al-Saleh, F.S.; Al-Harbi, A.A. [Girls College of Education, Riyadh (Saudi Arabia). Physics Dept.; Azzam, A. [Nuclear Research Center, Cairo (Egypt). Nuclear Physics Dept.

    2007-07-01

    Excitation functions for {sup 201}Pb, {sup 202m}Pb, {sup 203}Pb and {sup 204m}Pb radionuclides which are formed via proton induced reactions with natural thallium target have been measured from their respective threshold (E{sub thr}) to 27.5 MeV using activation technique. Natural copper foils were used to monitor the cyclotron beam. The integral yields (MBq/{mu}A h) of the produced radionuclides were calculated from the measured excitation functions. The optimum proton energy range for the production of {sup 203}Pb with low amount of impurities is (16-10 MeV) after 5 h of EOB. The experimental cross-sections for {sup nat}Tl(p,xn) reactions were compared with the cross-sections recommended by the IAEA and with earlier published data when it was possible. (orig.)

  4. Ion mobility spectrometry

    CERN Document Server

    Eiceman, GA

    2005-01-01

    Key Developments for Faster, More Precise Detection Capabilities Driven by the demand for the rapid and advanced detection of explosives, chemical and biological warfare agents, and narcotics, ion mobility spectrometry (IMS) undergone significant refinements in technology, computational capabilities, and understanding of the principles of gas phase ion chemistry and mobility. Beginning with a thorough discussion of the fundamental theories and physics of ion mobility, Ion Mobility Spectrometry, Second Edition describes the recent advances in instrumentation and newly

  5. Gas phase ion chemistry

    CERN Document Server

    Bowers, Michael T

    1979-01-01

    Gas Phase Ion Chemistry, Volume 2 covers the advances in gas phase ion chemistry. The book discusses the stabilities of positive ions from equilibrium gas-phase basicity measurements; the experimental methods used to determine molecular electron affinities, specifically photoelectron spectroscopy, photodetachment spectroscopy, charge transfer, and collisional ionization; and the gas-phase acidity scale. The text also describes the basis of the technique of chemical ionization mass spectrometry; the energetics and mechanisms of unimolecular reactions of positive ions; and the photodissociation

  6. Negative Ion Density Fronts

    Energy Technology Data Exchange (ETDEWEB)

    Igor Kaganovich

    2000-12-18

    Negative ions tend to stratify in electronegative plasmas with hot electrons (electron temperature Te much larger than ion temperature Ti, Te > Ti ). The boundary separating a plasma containing negative ions, and a plasma, without negative ions, is usually thin, so that the negative ion density falls rapidly to zero-forming a negative ion density front. We review theoretical, experimental and numerical results giving the spatio-temporal evolution of negative ion density fronts during plasma ignition, the steady state, and extinction (afterglow). During plasma ignition, negative ion fronts are the result of the break of smooth plasma density profiles during nonlinear convection. In a steady-state plasma, the fronts are boundary layers with steepening of ion density profiles due to nonlinear convection also. But during plasma extinction, the ion fronts are of a completely different nature. Negative ions diffuse freely in the plasma core (no convection), whereas the negative ion front propagates towards the chamber walls with a nearly constant velocity. The concept of fronts turns out to be very effective in analysis of plasma density profile evolution in strongly non-isothermal plasmas.

  7. Ion-kill dosimetry

    Science.gov (United States)

    Katz, R.; Cucinotta, F. A.; Fromm, M.; Chambaudet, A.

    2001-01-01

    Unanticipated late effects in neutron and heavy ion therapy, not attributable to overdose, imply a qualitative difference between low and high LET therapy. We identify that difference as 'ion kill', associated with the spectrum of z/beta in the radiation field, whose measurement we label 'ion-kill dosimetry'.

  8. Enhanced ion acoustic fluctuations and ion outflows

    Directory of Open Access Journals (Sweden)

    F. R. E. Forme

    1999-02-01

    Full Text Available A number of observations showing enhanced ion acoustic echoes observed by means of incoherent scatter radars have been reported in the literature. The received power is extremely enhanced by up to 1 or 2 orders of magnitude above usual values, and it is mostly contained in one of the two ion acoustic lines. This spectral asymmetry and the intensity of the received signal cannot be resolved by the standard analysis procedure and often causes its failure. As a result, and in spite of a very clear spectral signature, the analysis is unable to fit the plasma parameters inside the regions of ion acoustic turbulence. We present European Incoherent Scatter radar (EISCAT observations of large ion outflows associated with the simultaneous occurrence of enhanced ion acoustic echoes. The ion fluxes can reach 1014 m-2 s-1 at 800 km altitude. From the very clear spectral signatures of these echoes, a method is presented to extract estimates of the electron temperature and the ion drift within the turbulent regions. It is shown that the electron gas is strongly heated up to 11 000 K. Also electron temperature gradients of about 0.02 K/m exist. Finally, the estimates of the electron temperature and of the ion drift are used to study the possible implications for the plasma transport inside turbulent regions. It is shown that strong electron temperature gradients cause enhancement of the ambipolar electric field and can account for the observed ion outflows.Key words. Ionosphere (auroral ionosphere; ionosphere · magnetosphere interactions; plasma waves and instabilities.

  9. Vacuum Arc Ion Sources

    CERN Document Server

    Brown, I.

    2013-12-16

    The vacuum arc ion source has evolved into a more or less standard laboratory tool for the production of high-current beams of metal ions, and is now used in a number of different embodiments at many laboratories around the world. Applications include primarily ion implantation for material surface modification research, and good performance has been obtained for the injection of high-current beams of heavy-metal ions, in particular uranium, into particle accelerators. As the use of the source has grown, so also have the operational characteristics been improved in a variety of different ways. Here we review the principles, design, and performance of vacuum arc ion sources.

  10. Ion cyclotron resonance cell

    Science.gov (United States)

    Weller, R.R.

    1995-02-14

    An ion cyclotron resonance cell is disclosed having two adjacent sections separated by a center trapping plate. The first section is defined by the center trapping plate, a first end trapping plate, and excitation and detector electrodes. The second section includes a second end trapping plate spaced apart from the center plate, a mirror, and an analyzer. The analyzer includes a wavelength-selective light detector, such as a detector incorporating an acousto-optical device (AOD) and a photodetector. One or more ion guides, grounded plates with holes for the ion beam, are positioned within the vacuum chamber of the mass spectrometer between the ion source and the cell. After ions are trapped and analyzed by ion cyclotron resonance techniques in the first section, the ions of interest are selected according to their mass and passed into the second section for optical spectroscopic studies. The trapped ions are excited by light from a laser and caused thereby to fluoresce. The fluorescent light emitted by the excited ions is reflected by the mirror and directed onto the detector. The AOD is scanned, and the photodetector output is recorded and analyzed. The ions remain in the second section for an extended period, enabling multiple studies to be carried out on the same ensemble of ions. 5 figs.

  11. Crater formation by single ions, cluster ions and ion "showers"

    CERN Document Server

    Djurabekova, Flyura; Timko, Helga; Nordlund, Kai; Calatroni, Sergio; Taborelli, Mauro; Wuensch, Walter

    2011-01-01

    The various craters formed by giant objects, macroscopic collisions and nanoscale impacts exhibit an intriguing resemblance in shapes. At the same time, the arc plasma built up in the presence of sufficiently high electric fields at close look causes very similar damage on the surfaces. Although the plasma–wall interaction is far from a single heavy ion impact over dense metal surfaces or the one of a cluster ion, the craters seen on metal surfaces after a plasma discharge make it possible to link this event to the known mechanisms of the crater formations. During the plasma discharge in a high electric field the surface is subject to high fluxes (~1025 cm-2s-1) of ions with roughly equal energies typically of the order of a few keV. To simulate such a process it is possible to use a cloud of ions of the same energy. In the present work we follow the effect of such a flux of ions impinging the surface in the ‘‘shower’’ manner, to find the transition between the different mechanisms of crater formati...

  12. Microfabricated ion trap array

    Science.gov (United States)

    Blain, Matthew G [Albuquerque, NM; Fleming, James G [Albuquerque, NM

    2006-12-26

    A microfabricated ion trap array, comprising a plurality of ion traps having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale ion traps to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The reduced electrode voltage enables integration of the microfabricated ion trap array with on-chip circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of the microfabricated ion trap array can be realized in truly field portable, handheld microanalysis systems.

  13. Single ion TRICS

    Energy Technology Data Exchange (ETDEWEB)

    Bruce, J.A.; Anderson, G.A.; Hofstadler, S.A.; Smith, R.D. [Pacific Northwest Lab., Richland, WA (United States)

    1994-12-31

    A Fourier transform ion cyclotron resonance (FTICR) mass spectrometer has been used to trap individual, multiply charged ions of high molecular weight polymers, such as poly(ethylene oxide) (PEG). Accurate mass measurements of electrosprayed ions, or other multiply charge ions, requires determination of charge state. Trapping two or more large individual ions with the same mass, differing only by one additional charge is highly unlikely. Thus, exact mass assignments based on the measurement of charge state spacing to determine molecular weight is not feasible. Therefore, a new scheme was required to determine the mass of individual ions based on the observation of m/z shifts (i.e., cyclotron frequency shifts) resulting from reactions such as charge exchange or the adduction of a substance of a known mass. A new technique for mass determination of individual ions has been developed based on the observation of cyclotron frequency shifts during the time-domain acquisition period. This Time Resolved Ion Correlation (TRIC) technique allows reactant and product ions to be correlated with confidence by segmented Fourier transformation and comparison of extracted time-domain signals, and provides the basis for simultaneously studying a moderate number of ions.

  14. Macromolecular ion accelerator.

    Science.gov (United States)

    Hsu, Yun-Fei; Lin, Jung-Lee; Lai, Szu-Hsueh; Chu, Ming-Lee; Wang, Yi-Sheng; Chen, Chung-Hsuan

    2012-07-03

    Presented herein are the development of macromolecular ion accelerator (MIA) and the results obtained by MIA. This new instrument utilizes a consecutive series of planar electrodes for the purpose of facilitating stepwise acceleration. Matrix-assisted laser desorption/ionization (MALDI) is employed to generate singly charged macromolecular ions. A regular Z-gap microchannel plate (MCP) detector is mounted at the end of the accelerator to record the ion signals. In this work, we demonstrated the detection of ions with the mass-to-charge (m/z) ratio reaching 30,000,000. Moreover, we showed that singly charged biomolecular ions can be accelerated with the voltage approaching 1 MV, offering the evidence that macromolecular ions can possess much higher kinetic energy than ever before.

  15. Ion photon emission microscope

    Science.gov (United States)

    Doyle, Barney L.

    2003-04-22

    An ion beam analysis system that creates microscopic multidimensional image maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the ion-induced photons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted photons are collected in the lens system of a conventional optical microscope, and projected on the image plane of a high resolution single photon position sensitive detector. Position signals from this photon detector are then correlated in time with electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these photons initially.

  16. Materials analysis fast ions

    CERN Document Server

    Denker, A; Rauschenberg, J; Röhrich, J; Strub, E

    2006-01-01

    Materials analysis with ion beams exploits the interaction of ions with the electrons and nuclei in the sample. Among the vast variety of possible analytical techniques available with ion beams we will restrain to ion beam analysis with ion beams in the energy range from one to several MeV per mass unit. It is possible to use either the back-scattered projectiles (RBS – Rutherford Back Scattering) or the recoiled atoms itself (ERDA – Elastic Recoil Detection Analysis) from the elastic scattering processes. These techniques allow the simultaneous and absolute determination of stoichiometry and depth profiles of the detected elements. The interaction of the ions with the electrons in the sample produces holes in the inner electronic shells of the sample atoms, which recombine and emit X-rays characteristic for the element in question. Particle Induced X-ray Emission (PIXE) has shown to be a fast technique for the analysis of elements with an atomic number above 11.

  17. Lithium-ion batteries

    CERN Document Server

    Yoshio, Masaki; Kozawa, Akiya

    2010-01-01

    This book is a compilation of up-to-date information relative to Li-Ion technology. It provides the reader with a single source covering all important aspects of Li-Ion battery operations. It fills the gap between the old original Li-Ion technology and present state of the technology that has developed into a high state of practice. The book is designed to provide a single source for an up-to-date description of the technology associated with the Li-Ion battery industry. It will be useful to researchers interested in energy conversion for the direct conversion of chemical energy into electrica

  18. Correlation ion mobility spectroscopy

    Science.gov (United States)

    Pfeifer, Kent B [Los Lunas, NM; Rohde, Steven B [Corrales, NM

    2008-08-26

    Correlation ion mobility spectrometry (CIMS) uses gating modulation and correlation signal processing to improve IMS instrument performance. Closely spaced ion peaks can be resolved by adding discriminating codes to the gate and matched filtering for the received ion current signal, thereby improving sensitivity and resolution of an ion mobility spectrometer. CIMS can be used to improve the signal-to-noise ratio even for transient chemical samples. CIMS is especially advantageous for small geometry IMS drift tubes that can otherwise have poor resolution due to their small size.

  19. Ion-beam technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fenske, G.R. [Argonne National Lab., IL (United States)

    1993-01-01

    This compilation of figures and diagrams reviews processes for depositing diamond/diamond-like carbon films. Processes addressed are chemical vapor deposition (HFCVD, PACVD, etc.), plasma vapor deposition (plasma sputtering, ion beam sputtering, evaporation, etc.), low-energy ion implantation, and hybrid processes (biased sputtering, IBAD, biased HFCVD, etc.). The tribological performance of coatings produced by different means is discussed.

  20. Classification of Ion Sources

    OpenAIRE

    Scrivens, R.

    2014-01-01

    In this chapter, the anatomy of an ion source is briefly described, as well as a few features of particle motion in electric and magnetic fields, and of particle dynamics and plasmas. Using this information, different types of ion sources are described, highlighting their main mode of operation.

  1. Cooperativity in ion hydration

    NARCIS (Netherlands)

    Tielrooij, K.J.; Garcia-Araez, N.; Bonn, M.; Bakker, H.J.

    2010-01-01

    Despite prolonged scientific efforts to unravel the effects of ions on the structure and dynamics of water, many open questions remain, in particular concerning the spatial extent of this effect (i.e., the number of water molecules affected) and the origin of ion-specific effects. A combined

  2. CLASSICS The Ions

    Indian Academy of Sciences (India)

    Arrhenius theory of electrolytic dissociation, viz., in general, salts in solution dissociate to give ions. Ostwald, in 1888 gave a quantitative description of the dissociation, which was very useful in understanding the physical chemistry of solutions. The following portion 'The Ions' is from the book The Fundamental Principles of.

  3. Ion mobility sensor system

    Science.gov (United States)

    Xu, Jun; Watson, David B.; Whitten, William B.

    2013-01-22

    An ion mobility sensor system including an ion mobility spectrometer and a differential mobility spectrometer coupled to the ion mobility spectrometer. The ion mobility spectrometer has a first chamber having first end and a second end extending along a first direction, and a first electrode system that generates a constant electric field parallel to the first direction. The differential mobility spectrometer includes a second chamber having a third end and a fourth end configured such that a fluid may flow in a second direction from the third end to the fourth end, and a second electrode system that generates an asymmetric electric field within an interior of the second chamber. Additionally, the ion mobility spectrometer and the differential mobility spectrometer form an interface region. Also, the first end and the third end are positioned facing one another so that the constant electric field enters the third end and overlaps the fluid flowing in the second direction.

  4. Lipid Ion Channels

    CERN Document Server

    Heimburg, Thomas

    2010-01-01

    The interpretation electrical phenomena in biomembranes is usually based on the assumption that the experimentally found discrete ion conduction events are due to a particular class of proteins called ion channels while the lipid membrane is considered being an inert electrical insulator. The particular protein structure is thought to be related to ion specificity, specific recognition of drugs by receptors and to macroscopic phenomena as nerve pulse propagation. However, lipid membranes in their chain melting regime are known to be highly permeable to ions, water and small molecules, and are therefore not always inert. In voltage-clamp experiments one finds quantized conduction events through protein-free membranes in their melting regime similar to or even undistinguishable from those attributed to proteins. This constitutes a conceptual problem for the interpretation of electrophysiological data obtained from biological membrane preparations. Here, we review the experimental evidence for lipid ion channels...

  5. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  6. Ion channel pharmacology.

    Science.gov (United States)

    Camerino, Diana Conte; Tricarico, Domenico; Desaphy, Jean-François

    2007-04-01

    Because ion channels are involved in many cellular processes, drugs acting on ion channels have long been used for the treatment of many diseases, especially those affecting electrically excitable tissues. The present review discusses the pharmacology of voltage-gated and neurotransmitter-gated ion channels involved in neurologic diseases, with emphasis on neurologic channelopathies. With the discovery of ion channelopathies, the therapeutic value of many basic drugs targeting ion channels has been confirmed. The understanding of the genotype-phenotype relationship has highlighted possible action mechanisms of other empirically used drugs. Moreover, other ion channels have been pinpointed as potential new drug targets. With regards to therapy of channelopathies, experimental investigations of the intimate drug-channel interactions have demonstrated that channel mutations can either increase or decrease affinity for the drug, modifying its potential therapeutic effect. Together with the discovery of channel gene polymorphisms that may affect drug pharmacodynamics, these findings highlight the need for pharmacogenetic research to allow identification of drugs with more specific effects on channel isoforms or mutants, to increase efficacy and reduce side effects. With a greater understanding of channel genetics, structure, and function, together with the identification of novel primary and secondary channelopathies, the number of ion channel drugs for neurologic channelopathies will increase substantially.

  7. Ion optics of RHIC electron beam ion source.

    Science.gov (United States)

    Pikin, A; Alessi, J; Beebe, E; Kponou, A; Okamura, M; Raparia, D; Ritter, J; Tan, Y; Kuznetsov, G

    2012-02-01

    RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  8. Ion dynamics during seizures

    Directory of Open Access Journals (Sweden)

    Joseph Valentino Raimondo

    2015-10-01

    Full Text Available Changes in membrane voltage brought about by ion fluxes through voltage and transmitter-gated channels represent the basis of neural activity. As such, electrochemical gradients across the membrane determine the direction and driving force for the flow of ions and are therefore crucial in setting the properties of synaptic transmission and signal propagation. Ion concentration gradients are established by a variety of mechanisms, including specialised transporter proteins. However, transmembrane gradients can be affected by ionic fluxes through channels during periods of elevated neural activity, which in turn are predicted to influence the properties of on-going synaptic transmission. Such activity-induced changes to ion concentration gradients are a feature of both physiological and pathological neural processes. An epileptic seizure is an example of severely perturbed neural activity, which is accompanied by pronounced changes in intracellular and extracellular ion concentrations. Appreciating the factors that contribute to these ion dynamics is critical if we are to understand how a seizure event evolves and is sustained and terminated by neural tissue. Indeed, this issue is of significant clinical importance as status epilepticus – a type of seizure that does not stop of its own accord – is a life-threatening medical emergency. In this review we explore how the transmembrane concentration gradient of the six major ions (K+, Na+, Cl-, Ca2+, H+ and HCO3- is altered during an epileptic seizure. We will first examine each ion individually, before describing how multiple interacting mechanisms between ions might contribute to concentration changes and whether these act to prolong or terminate epileptic activity. In doing so, we will consider how the availability of experimental techniques has both advanced and restricted our ability to study these phenomena.

  9. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  10. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi [Gunma Prefectural Cardiovascular Center, Maebashi (Japan)] [and others

    2000-04-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V{sub 2}, V{sub 3} and V{sub 4} leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV{sub F}, V{sub 5} and V{sub 6} leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  11. Ion exchange phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Bourg, I.C.; Sposito, G.

    2011-05-01

    Ion exchange phenomena involve the population of readily exchangeable ions, the subset of adsorbed solutes that balance the intrinsic surface charge and can be readily replaced by major background electrolyte ions (Sposito, 2008). These phenomena have occupied a central place in soil chemistry research since Way (1850) first showed that potassium uptake by soils resulted in the release of an equal quantity of moles of charge of calcium and magnesium. Ion exchange phenomena are now routinely modeled in studies of soil formation (White et al., 2005), soil reclamation (Kopittke et al., 2006), soil fertilitization (Agbenin and Yakubu, 2006), colloidal dispersion/flocculation (Charlet and Tournassat, 2005), the mechanics of argillaceous media (Gajo and Loret, 2007), aquitard pore water chemistry (Tournassat et al., 2008), and groundwater (Timms and Hendry, 2007; McNab et al., 2009) and contaminant hydrology (Chatterjee et al., 2008; van Oploo et al., 2008; Serrano et al., 2009).

  12. Sensing with Ion Channels

    CERN Document Server

    Martinac, Boris

    2008-01-01

    All living cells are able to detect and translate environmental stimuli into biologically meaningful signals. Sensations of touch, hearing, sight, taste, smell or pain are essential to the survival of all living organisms. The importance of sensory input for the existence of life thus justifies the effort made to understand its molecular origins. Sensing with Ion Channels focuses on ion channels as key molecules enabling biological systems to sense and process the physical and chemical stimuli that act upon cells in their living environment. Its aim is to serve as a reference to ion channel specialists and as a source of new information to non specialists who want to learn about the structural and functional diversity of ion channels and their role in sensory physiology.

  13. Multi-Ion Magnetohydrodynamics

    Science.gov (United States)

    Toth, G.; Glocer, A.; Ma, Y.; Najib, D.; Gombosi, T.

    2010-09-01

    We derive and numerically solve the full set of magnetohydrodynamic equations with multiple ion fluids. The numerical difficulties and the algorithmic solutions are discussed. We show some preliminary results for the interaction of Mars' ionosphere with the solar wind.

  14. Ion Mass Determination

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (100) is described for determining the mass of ions, the apparatus configured to hold a plasma (101 ) having a plasma potential. The apparatus (100) comprises an electrode (102) having a surface extending in a surface plane and an insulator (104) interfacing with the electrode (102......, and a processing unit (108) configured to interpret the detected impact locations in terms of the mass of the impacting ions....

  15. Ion exchange equilibrium constants

    CERN Document Server

    Marcus, Y

    2013-01-01

    Ion Exchange Equilibrium Constants focuses on the test-compilation of equilibrium constants for ion exchange reactions. The book first underscores the scope of the compilation, equilibrium constants, symbols used, and arrangement of the table. The manuscript then presents the table of equilibrium constants, including polystyrene sulfonate cation exchanger, polyacrylate cation exchanger, polymethacrylate cation exchanger, polysterene phosphate cation exchanger, and zirconium phosphate cation exchanger. The text highlights zirconium oxide anion exchanger, zeolite type 13Y cation exchanger, and

  16. Miniaturized Ion Mobility Spectrometer

    Science.gov (United States)

    Kaye, William J (Inventor); Stimac, Robert M. (Inventor)

    2017-01-01

    By utilizing the combination of a unique electronic ion injection control circuit in conjunction with a particularly designed drift cell construction, the instantly disclosed ion mobility spectrometer (IMS) achieves increased levels of sensitivity, while achieving significant reductions in size and weight. The instant IMS is of a much simpler and easy to manufacture design, rugged and hermetically sealed, capable of operation at high temperatures to at least 250 degrees Centigrade, and is uniquely sensitive, particularly to explosive chemicals.

  17. Numerical Simulation of Multicomponent Ion Beam from Ion Sources

    CERN Document Server

    Alexandrov, V S; Kazarinov, Yu M; Shevtsov, V P; Shirkov, G D

    1999-01-01

    A program library for numerical simulation of a multicomponent charged particle beam from ion sources is presented. The library is aimed for simulation of high current, low energy multicomponent ion beam from ion source through beamline and realized under the Windows user interface for the IBM PC. It is used for simulation and optimization of beam dynamics and based on successive and consistent application of two methods: the momentum method of distribution function (RMS technique) and particle in cell method. The library has been used to simulate and optimize the transportation of tantalum ion beam from the laser ion source (CERN) and calcium ion beam from the ECR ion source (JINR, Dubna).

  18. 2010 ion run: completed!

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    After a very fast switchover from protons to lead ions, the LHC has achieved performances that allowed the machine to exceed both peak and integrated luminosity by a factor of three. Thanks to this, experiments have been able to produce high-profile results on ion physics almost immediately, confirming that the LHC was able to keep its promises for ions as well as for protons.   First direct observation of jet quenching. A seminar on 2 December was the opportunity for the ALICE, ATLAS and CMS collaborations to present their first results on ion physics in front of a packed auditorium. These results are important and are already having a major impact on the understanding of the physics processes that involve the basic constituents of matter at high energies. In the ion-ion collisions, the temperature is so high that partons (quarks and gluons), which are usually constrained inside the nucleons, are deconfined to form a highly dense and hot soup known as quark-gluon plasma (QGP). The existence of ...

  19. Radiative ion-ion neutralization: a new gas-phase atmospheric pressure ion transduction mechanism.

    Science.gov (United States)

    Davis, Eric J; Siems, William F; Hill, Herbert H

    2012-06-05

    All atmospheric pressure ion detectors, including photo ionization detectors, flame ionization detectors, electron capture detectors, and ion mobility spectrometers, utilize Faraday plate designs in which ionic charge is collected and amplified. The sensitivity of these Faraday plate ion detectors are limited by thermal (Johnson) noise in the associated electronics. Thus approximately 10(6) ions per second are required for a minimal detection. This is not the case for ion detection under vacuum conditions where secondary electron multipliers (SEMs) can be used. SEMs produce a cascade of approximately 10(6) electrons per ion impinging on the conversion dynode. Similarly, photomultiplier tubes (PMTs) can generate approximately 10(6) electrons per photon. Unlike SEMs, however, PMTs are evacuated and sealed so that they are commonly used under atmospheric pressure conditions. This paper describes an atmospheric pressure ion detector based on coupling a PMT with light emitted from ion-ion neutralization reactions. The normal Faraday plate collector electrode was replaced with an electrode "needle" used to concentrate the anions as they were drawn to the tip of the needle by a strong focusing electric field. Light was emitted near the surface of the electrode when analyte ions were neutralized with cations produced from the anode. Although radiative-ion-ion recombination has been previously reported, this is the first time ions from separate ionization sources have been combined to produce light. The light from this radiative-ion-ion-neutralization (RIIN) was detected using a photon multiplier such that an ion mobility spectrum was obtained by monitoring the light emitted from mobility separated ions. An IMS spectrum of nitroglycerin (NG) was obtained utilizing RIIN for tranducing the mobility separated ions into an analytical signal. The implications of this novel ion transduction method are the potential for counting ions at atmospheric pressure and for obtaining ion

  20. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1983-01-01

    Ion-Selective Electrode Reviews, Volume 5 is a collection of articles that covers ion-speciation. The book aims to present the advancements of the range and capabilities of selective ion-sensors. The topics covered in the selection are neutral carrier based ion-selective electrodes; reference electrodes and liquid junction effects in ion-selective electrode potentiometry; ion transfer across water/organic phase boundaries and analytical; and carbon substrate ion-selective electrodes. The text will be of great use to chemists and chemical engineers.

  1. Ion optics of RHIC EBIS

    Energy Technology Data Exchange (ETDEWEB)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Okamura, M.; Raparia, D.; Ritter, J.; Tan, Y.; Kuznetsov, G.

    2011-09-10

    RHIC EBIS has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  2. Silane Discharge Ion Chemistry.

    Science.gov (United States)

    Chatham, Robert Hood, III

    We have studied silane dc, rf and dc proximity discharges, using mass spectroscopic measurements of the positive ions as a detailed diagnostic for the type of discharge used to produce hydrogenated amorphous silicon solar photovoltaic cells. The properties and quality of these films depends in a very complex way upon the interactions of the many reactive neutral and ion species in the discharge. We have developed qualitative models of the ion chemical processes in these discharges from our measurements. Knowledge of the ion-molecule and electron-molecule collision cross sections is important to any attempt at understanding silane discharge chemistry. Consequently, we have measured the electron impact ionization cross sections for silane and disilane, and for comparison purposes also for methane and ethane. In addition, we have measured the rate coefficients for charge exchange reactions of He('+), Ne('+), and Ar('+) with silane, disilane, methane, and ethane, as these are important to understanding discharges in inert gas-silane mixtures. We have developed a detailed quantitative model of the cathode sheath region of a silane dc discharge, by extending the best recent calculation of the electron motion in the sheath to a self-consistent form which includes the ion motion. This model is used with comparison of silane dc discharge data to diagnose the ion chemistry occurring in the sheath region of silane dc discharge. The understanding of the discharge ion chemical processes that we have gained in this study represent an important step toward understanding the chemical and physical processes leading to film growth.

  3. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1985-01-01

    Ion-Selective Electrode Reviews, Volume 7 is a collection of papers that covers the applications of electrochemical sensors, along with the versatility of ion-selective electrodes. The coverage of the text includes solid contact in membrane ion-selective electrodes; immobilized enzyme probes for determining inhibitors; potentiometric titrations based on ion-pair formation; and application of ion-selective electrodes in soil science, kinetics, and kinetic analysis. The text will be of great use to chemists and chemical engineers.

  4. The ion circus

    Energy Technology Data Exchange (ETDEWEB)

    Minaya Ramirez, Enrique [GSI Helmholtzzentrum, Darmstadt (Germany); Lunney, David [CSNSM- IN2P3/CNRS, Universite de Paris-Sud, Orsay (France)

    2010-07-01

    The ability to prepare radioactive beams for experiments in nuclear structure has seen important developments in recent years. The use of ion traps and buffer-gas cooling now enables the accumulation and purification of even short-lived nuclides. This is a key point for future installations since higher intensity also brings increased isobaric contamination which can be disastrous for background. Until now, the development of beam cooler/bunchers has relied on linear (radiofrequency quadrupole) Paul traps. In this contribution we describe the progress in developing a novel circular Paul trap. The ion circus, so named for its ability to trap ions at different positions along the ring circumference and to eject them in either perpendicular or tangential direction, has also been designed to cool and mass separate the ions over a longer flight path. The resolving power is increased as the ions orbit in the ring and are cooled with buffer gas at a much lower pressure. The first prototype is now under test in Orsay. We report results of the first tests and the future program.

  5. Molecular ion photofragment spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bustamente, S.W.

    1983-11-01

    A new molecular ion photofragment spectrometer is described which features a supersonic molecular beam ion source and a radio frequency octapole ion trap interaction region. This unique combination allows several techniques to be applied to the problem of detecting a photon absorption event of a molecular ion. In particular, it may be possible to obtain low resolution survey spectra of exotic molecular ions by using a direct vibrational predissociation process, or by using other more indirect detection methods. The use of the spectrometer is demonstrated by measuring the lifetime of the O/sub 2//sup +/(/sup 4/..pi../sub u/) metastable state which is found to consist of two main components: the /sup 4/..pi../sub 5/2/ and /sup 4/..pi../sub -1/2/ spin components having a long lifetime (approx. 129 ms) and the /sup 4/..pi../sub 3/2/ and /sup 4/..pi../sub 1/2/ spin components having a short lifetime (approx. 6 ms).

  6. Laser ion source for isobaric heavy ion collider experiment.

    Science.gov (United States)

    Kanesue, T; Kumaki, M; Ikeda, S; Okamura, M

    2016-02-01

    Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is (96)Ru + (96)Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions.

  7. Ion-selective electrodes

    CERN Document Server

    Mikhelson, Konstantin N

    2013-01-01

    Ion-selective electrodes (ISEs) have a wide range of applications in clinical, environmental, food and pharmaceutical analysis as well as further uses in chemistry and life sciences. Based on his profound experience as a researcher in ISEs and a course instructor, the author summarizes current knowledge for advanced teaching and training purposes with a particular focus on ionophore-based ISEs. Coverage includes the basics of measuring with ISEs, essential membrane potential theory and a comprehensive overview of the various classes of ion-selective electrodes. The principles of constructing I

  8. Magnetic ions in crystals

    CERN Document Server

    Stevens, K W

    2014-01-01

    There have been many demonstrations, particularly for magnetic impurity ions in crystals, that spin-Hamiltonians are able to account for a wide range of experimental results in terms of much smaller numbers of parameters. Yet they were originally derived from crystal field theory, which contains a logical flaw; electrons on the magnetic ions are distinguished from those on the ligands. Thus there is a challenge: to replace crystal field theory with one of equal or greater predictive power that is based on a surer footing. The theory developed in this book begins with a generic Hamiltonian, on

  9. Interferometry with Strontium Ions

    Science.gov (United States)

    Jackson, Jarom; Lambert, Enoch; Otterstrom, Nils; Jones, Tyler; Durfee, Dallin

    2014-05-01

    We describe progress on a cold ion matter-wave interferometer. Cold Strontium atoms are extracted from an LVIS. The atoms will be photo-ionized with a two-photon transition to an auto-ionizing state in the continuum. The ions will be split and recombined using stimulated Raman transitions from a pair of diode lasers injection locked to two beams from a master laser which have been shifted up and down by half the hyperfine splitting. We are developing laser instrumentation for this project including a method to prevent mode-hopping by analyzing laser frequency noise, and an inexpensive, robust wavelength meter. Supported by NSF Award No. 1205736.

  10. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve: A single-center prospective study.

    Science.gov (United States)

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-12-01

    The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD).We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC.FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = -0.584 and r = -0.568, respectively, both P < .001). Receiver-operating characteristics analyses using rSDS revealed an optimal FFR cut-off of <0.80 without and with CT-AC. Although the diagnostic accuracy of FFR <0.80 did not significantly differ, FFR ≥0.82 was significantly more accurate with, than without CT-AC. Regions with rSDS ≥2 without or with CT-AC predicted FFR <0.80, and those with rSDS ≤1 without and with CT-AC predicted FFR ≥0.81, with 73% and 83% sensitivity, 84% and 67% specificity, and 79% and 75% accuracy, respectively.Although limited by the sample size and the single-center design, these findings showed that the IQ-SPECT system can predict FFR at an optimal cut-off of <0.80, and we propose a novel application of CT-AC to MPI-IQ-SPECT for predicting clinically significant and insignificant FFR even in nonobese patients. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  11. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-{beta}-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Shimoyama, Katsuya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-10-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using {sup 123}I-{beta}-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and {sup 201}thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p<0.042). However, when Tl defect score was larger than BMIPP defect score, an increase in Tl defect score was slight. A significant negative correlation was found between the sum of the BMIPP and Tl defect scores and the left ventricular ejection fraction (LVEF) (r=0.66, p<0.0001). According to the histo-pathological study of two autopsied hearts, severe myocardial fibrosis was seen in segments with fixed perfusion defect. In addition, the mismatched segments of BMIPP defect score > Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  12. Analytical applications of ion exchangers

    CERN Document Server

    Inczédy, J

    1966-01-01

    Analytical Applications of Ion Exchangers presents the laboratory use of ion-exchange resins. This book discusses the development in the analytical application of ion exchangers. Organized into 10 chapters, this book begins with an overview of the history and significance of ion exchangers for technical purposes. This text then describes the properties of ion exchangers, which are large molecular water-insoluble polyelectrolytes having a cross-linked structure that contains ionic groups. Other chapters consider the theories concerning the operation of ion-exchange resins and investigate th

  13. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1982-01-01

    Ion-Selective Electrode Reviews, Volume 3, provides a review of articles on ion-selective electrodes (ISEs). The volume begins with an article on methods based on titration procedures for surfactant analysis, which have been developed for discrete batch operation and for continuous AutoAnalyser use. Separate chapters deal with detection limits of ion-selective electrodes; the possibility of using inorganic ion-exchange materials as ion-sensors; and the effect of solvent on potentials of cells with ion-selective electrodes. Also included is a chapter on advances in calibration procedures, the d

  14. Ion-dust streaming instability with non-Maxwellian ions

    Energy Technology Data Exchange (ETDEWEB)

    Kählert, Hanno, E-mail: kaehlert@theo-physik.uni-kiel.de [Institut für Theoretische Physik und Astrophysik, Christian-Albrechts-Universität zu Kiel, Leibnizstr. 15, 24098 Kiel (Germany)

    2015-07-15

    The influence of non-Maxwellian ions on the ion-dust streaming instability in a complex plasma is investigated. The ion susceptibility employed for the calculations self-consistently accounts for the acceleration of the ions by a homogeneous background electric field and their collisions with neutral gas particles via a Bhatnagar-Gross-Krook collision term [e.g., A. V. Ivlev et al., Phys. Rev. E 71, 016405 (2005)], leading to significant deviations from a shifted Maxwellian distribution. The dispersion relation and the properties of the most unstable mode are studied in detail and compared with the Maxwellian case. The largest deviations occur at low to intermediate ion-neutral damping. In particular, the growth rate of the instability for ion streaming below the Bohm speed is found to be lower than in the case of Maxwellian ions, yet remains on a significant level even for fast ion flows above the Bohm speed.

  15. Quadrupole Ion Traps

    Indian Academy of Sciences (India)

    ), while in the Paul trap a RF potential is applied to the electrodes (Figure 4b). The Penning Trap. It is now clear that, the dc field provides confinement of the ions along the axial direction while there is a repulsive force in the .... _--.-----. Zo. Lr. o.

  16. Lithium ion conducting electrolytes

    Science.gov (United States)

    Angell, Charles Austen; Liu, Changle; Xu, Kang; Skotheim, Terje A.

    1999-01-01

    The present invention relates generally to highly conductive alkali-metal ion non-crystalline electrolyte systems, and more particularly to novel and unique molten (liquid), rubbery, and solid electrolyte systems which are especially well suited for use with high current density electrolytic cells such as primary and secondary batteries.

  17. Lithium ion conducting electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Angell, C.A.; Liu, C.; Xu, K.; Skotheim, T.A.

    1999-10-05

    The present invention relates generally to highly conductive alkali-metal ion non-crystalline electrolyte systems, and more particularly to novel and unique molten (liquid), rubbery, and solid electrolyte systems which are especially well suited for use with high current density electrolytic cells such as primary and secondary batteries.

  18. Anodes sliced with ions

    NARCIS (Netherlands)

    Boukamp, Bernard A.

    2006-01-01

    A detailed image of a complex fuel-cell anode structure, obtained through ion-beam milling, SEM imaging and advanced digital reconstruction, yields an accurate description of the three-dimensional structure, and enables correct prediction of the electrode's properties

  19. Polyatomic ions from a high current ion implanter driven by a liquid metal ion source.

    Science.gov (United States)

    Pilz, W; Laufer, P; Tajmar, M; Böttger, R; Bischoff, L

    2017-12-01

    High current liquid metal ion sources are well known and found their first application as field emission electric propulsion thrusters in space technology. The aim of this work is the adaption of such kind of sources in broad ion beam technology. Surface patterning based on self-organized nano-structures on, e.g., semiconductor materials formed by heavy mono- or polyatomic ion irradiation from liquid metal (alloy) ion sources (LMAISs) is a very promising technique. LMAISs are nearly the only type of sources delivering polyatomic ions from about half of the periodic table elements. To overcome the lack of only very small treated areas by applying a focused ion beam equipped with such sources, the technology taken from space propulsion systems was transferred into a large single-end ion implanter. The main component is an ion beam injector based on high current LMAISs combined with suited ion optics allocating ion currents in the μA range in a nearly parallel beam of a few mm in diameter. Different types of LMAIS (needle, porous emitter, and capillary) are presented and characterized. The ion beam injector design is specified as well as the implementation of this module into a 200 kV high current ion implanter operating at the HZDR Ion Beam Center. Finally, the obtained results of large area surface modification of Ge using polyatomic Bi 2 + ions at room temperature from a GaBi capillary LMAIS will be presented and discussed.

  20. Ion transport from plasma ion source at ISOLTRAP

    CERN Document Server

    Steinsberger, Timo Pascal

    2017-01-01

    In this report, my work as CERN Summer Student at the ISOLTRAP experiment at ISOLDE is described. A new plasma ion source used as oine source for calibration and implemented before my arrival was commissioned and transportation settings for the produced ions to the ion traps were found. The cyclotron frequencies of 40Ar and the xenon isotopes 129-132Xe were measured using time-of-flight and phase-imaging ion-cyclotron-resonance mass spectroscopy.

  1. Ion-Beam-Excited Electrostatic Ion Cyclotron Waves

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field.......Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field....

  2. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion ...

  3. Unstable Electrostatic Ion Cyclotron Waves Exited by an Ion Beam

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Electrostatic ion cyclotron waves were observed in a quiescent cesium plasma into which a low‐energy beam of sodium ions was injected. The instability appeared when the beam velocity was above 12 times the ion thermal velocity. The waves propagated along the magnetic field with a velocity somewhat...

  4. Using Ion Exchange Chromatography to Separate and Quantify Complex Ions

    Science.gov (United States)

    Johnson, Brian J.

    2014-01-01

    Ion exchange chromatography is an important technique in the separation of charged species, particularly in biological, inorganic, and environmental samples. In this experiment, students are supplied with a mixture of two substitution-inert complex ions. They separate the complexes by ion exchange chromatography using a "flash"…

  5. Prolonging coherence in trapped ions

    CSIR Research Space (South Africa)

    Uys, H

    2010-09-01

    Full Text Available The authors study pulse sequences that dynamically decouple 9Be+ ions from their decohering environment. The noise environment the ions see is artificially synthesized to emulate a variety of physical systems. By incorporating measurement feedback...

  6. Membranes in Lithium Ion Batteries

    Directory of Open Access Journals (Sweden)

    Junbo Hou

    2012-07-01

    Full Text Available Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed.

  7. Membranes in Lithium Ion Batteries

    Science.gov (United States)

    Yang, Min; Hou, Junbo

    2012-01-01

    Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed. PMID:24958286

  8. The Ion Conveyor. An ion focusing and conveying device.

    Science.gov (United States)

    Colburn, Alex W; Giannakopulos, A E; Derrick, Peter J

    2004-01-01

    The control and transmission of ions or small charged droplets in the intermediate to high-pressure regime is of primary importance in areas such as atmospheric pressure ionisation. Where small apertures separate differentially pumped vacuum regions in the inlet systems to mass spectrometers, a large proportion of the available ion current is lost to the surrounding electrode structures. A new ion-optical device, named the ion conveyor, incorporating electrodynamic focusing and conveying of charged entities is described. Results from ion-optical simulations are presented demonstrating the performance of the device in various operating modes and electrode configurations.

  9. Ion Accelerator Merges Several Beams

    Science.gov (United States)

    Aston, G.

    1984-01-01

    Intense ion beam formed by merging multiple ion beamlets into one concentrated beam. Beamlet holes in graphite screen and focusing grids arranged in hexagonal pattern. Merged beam passes through single hole in each of aluminum accelerator and decelerator grids. Ion extraction efficiency, beam intensity, and focusing improved.

  10. Scanning ion microscopy with low energy lithium ions

    Energy Technology Data Exchange (ETDEWEB)

    Twedt, Kevin A. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Maryland NanoCenter, University of Maryland, College Park, MD 20742 (United States); Chen, Lei [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); McClelland, Jabez J., E-mail: jabez.mcclelland@nist.gov [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2014-07-01

    Using an ion source based on photoionization of laser-cooled lithium atoms, we have developed a scanning ion microscope with probe sizes of a few tens of nanometers and beam energies from 500 eV to 5 keV. These beam energies are much lower than the typical operating energies of the helium ion microscope or gallium focused ion beam systems. We demonstrate how low energy can be advantageous in ion microscopy when detecting backscattered ions, due to a decreased interaction volume and the potential for surface sensitive composition analysis. As an example application that demonstrates these advantages, we non-destructively image the removal of a thin residual resist layer during plasma etching in a nano-imprint lithography process. - Highlights: • We use an ion source based on photoionization of laser-cooled lithium atoms. • The ion source makes possible a low energy (500 eV to 5 keV) scanning ion microscope. • Low energy is preferred for ion microscopy with backscattered ions. • We use the microscope to image a thin resist used in nano-imprint lithography.

  11. Ion bipolar junction transistors.

    Science.gov (United States)

    Tybrandt, Klas; Larsson, Karin C; Richter-Dahlfors, Agneta; Berggren, Magnus

    2010-06-01

    Dynamic control of chemical microenvironments is essential for continued development in numerous fields of life sciences. Such control could be achieved with active chemical circuits for delivery of ions and biomolecules. As the basis for such circuitry, we report a solid-state ion bipolar junction transistor (IBJT) based on conducting polymers and thin films of anion- and cation-selective membranes. The IBJT is the ionic analogue to the conventional semiconductor BJT and is manufactured using standard microfabrication techniques. Transistor characteristics along with a model describing the principle of operation, in which an anionic base current amplifies a cationic collector current, are presented. By employing the IBJT as a bioelectronic circuit element for delivery of the neurotransmitter acetylcholine, its efficacy in modulating neuronal cell signaling is demonstrated.

  12. Trapped Ion Qubits

    Energy Technology Data Exchange (ETDEWEB)

    Maunz, Peter Lukas Wilhelm

    2017-04-01

    Qubits can be encoded in clock states of trapped ions. These states are well isolated from the environment resulting in long coherence times [1] while enabling efficient high-fidelity qubit interactions mediated by the Coulomb coupled motion of the ions in the trap. Quantum states can be prepared with high fidelity and measured efficiently using fluorescence detection. State preparation and detection with 99.93% fidelity have been realized in multiple systems [1,2]. Single qubit gates have been demonstrated below rigorous fault-tolerance thresholds [1,3]. Two qubit gates have been realized with more than 99.9% fidelity [4,5]. Quantum algorithms have been demonstrated on systems of 5 to 15 qubits [6–8].

  13. Improving Ion Computed Tomography

    DEFF Research Database (Denmark)

    Hansen, David Christoffer

    2014-01-01

    -HIT, og de blev tilpasset eksperimentelle tværsnit. Modellerne passede godt med eksperimentelle målinger af kernefragmentation af kulstof i vand, hvorimod der var større afvigelser for neon. I tidligere undersøgelser af ion CT med ioner tungere end brint har dosis altid været meget høj, i flere tilfælde...

  14. Ion funnel device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Chen, Tsung-Chi; Harrer, Marques B.; Tang, Keqi; Smith, Richard D.

    2017-11-21

    An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

  15. Ion Acoustic Microscopy

    Science.gov (United States)

    1985-07-01

    Murphy and L. C. Aamodt , "Signal Enhancement in Photothermal Imaging Produced by Three Dimensional Heat Flow", Appl. Phys. Lett. 39, 519 (1981); L. C... Aamodt and J. C. Murphy, "Photothermal Measurements Using a Localized Excitation Source", J. Appl. Phys. 52, 4903 (1981) (9) R. L. Thomas, L. D. Favro...25 (23) J. C. Murphy, F. G. Satkiewicz and L. C. Aamodt , "Ion Acoustic Imaging of Buried Flaws in Aluminum", Review of Progress in Quantitative NDE

  16. Micro Ion Frequency Standard

    Science.gov (United States)

    2009-11-01

    Figure 6. (a) Fabricated VCSEL . (b) Emission spectrum of VCSEL at 1 mA drive current . As expected, our initial VCSEL wafers produced much less...light source at 369 nm. (a) (b) Figure 7. (a) 740-nm VCSEL output power and voltage versus current . (b) Periodically poled KTP crystal with...micro ion frequency standard and relevant current results. INTRODUCTION Vapor cell atomic clocks have seen extreme miniaturization within the past

  17. Superheated Water Ion-exchange Chromatography

    National Research Council Canada - National Science Library

    SHIBUKAWA, Masami; MORINAGA, Ryota; SAITO, Shingo

    2016-01-01

    ... superheated water chromatography. The selectivity coefficient for a pair of identically charged inorganic ions, such as alkali metal ions and halide ions, approaches unity as the temperature increases, provided that the ions...

  18. Ion channeling revisited

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, Barney Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Corona, Aldo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nguyen, Anh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    A MS Excel program has been written that calculates accidental, or unintentional, ion channeling in cubic bcc, fcc and diamond lattice crystals or polycrystalline materials. This becomes an important issue when simulating the creation by energetic neutrons of point displacement damage and extended defects using beams of ions. All of the tables and graphs in the three Ion Beam Analysis Handbooks that previously had to be manually looked up and read from were programed into Excel in handy lookup tables, or parameterized, for the case of the graphs, using rather simple exponential functions with different powers of the argument. The program then offers an extremely convenient way to calculate axial and planar half-angles and minimum yield or dechanneling probabilities, effects on half-angles of amorphous overlayers, accidental channeling probabilities for randomly oriented crystals or crystallites, and finally a way to automatically generate stereographic projections of axial and planar channeling half-angles. The program can generate these projections and calculate these probabilities for axes and [hkl] planes up to (555).

  19. Novel laser ion sources

    CERN Document Server

    Fournier, P; Kugler, H; Lisi, N; Scrivens, R; Rodríguez, F V; Düsterer, S; Sauerbrey, R; Schillinger, H; Theobald, W; Veisz, L; Tisch, J W G; Smith, R A

    2000-01-01

    Development in the field of high-power laser systems with repetition rates of several Hz and energies of few joules is highly active and opening, giving new possibilities for the design of laser ions sources. Preliminary investigations on the use of four different laser and target configurations are presented: (1) A small CO/sub 2/ laser (100 mJ, 10.6 mu m) focused onto a polyethylene target to produce C ions at 1 Hz repetition rate (CERN). (2) An excimer XeCl laser (6 J, 308 nm) focused onto solid targets (Frascati). (3) A femtosecond Ti: sapphire laser (250 mJ, 800 nm) directed onto a solid targets (Jena). (4) A picosecond Nd: yttrium-aluminum-garnet (0.3 J, 532 nm) focused into a dense medium of atomic clusters and onto solid targets (London). The preliminary experimental results and the most promising schemes will be discussed with respect to the scaling of the production of high numbers of highly charged ions. Different lasers are compared in terms of current density at 1 m distance for each charge state...

  20. Resonance Ionization Laser Ion Sources

    CERN Document Server

    Marsh, B

    2013-01-01

    The application of the technique of laser resonance ionization to the production of singly charged ions at radioactive ion beam facilities is discussed. The ability to combine high efficiency and element selectivity makes a resonance ionization laser ion source (RILIS) an important component of many radioactive ion beam facilities. At CERN, for example, the RILIS is the most commonly used ion source of the ISOLDE facility, with a yearly operating time of up to 3000 hours. For some isotopes the RILIS can also be used as a fast and sensitive laser spectroscopy tool, provided that the spectral resolution is sufficiently high to reveal the influence of nuclear structure on the atomic spectra. This enables the study of nuclear properties of isotopes with production rates even lower than one ion per second and, in some cases, enables isomer selective ionization. The solutions available for the implementation of resonance laser ionization at radioactive ion beam facilities are summarized. Aspects such as the laser r...

  1. Electron string ion sources for carbon ion cancer therapy accelerators

    Science.gov (United States)

    Boytsov, A. Yu.; Donets, D. E.; Donets, E. D.; Donets, E. E.; Katagiri, K.; Noda, K.; Ponkin, D. O.; Ramzdorf, A. Yu.; Salnikov, V. V.; Shutov, V. B.

    2015-08-01

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C4+ and C6+ ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 1010 C4+ ions per pulse and about 5 × 109 C6+ ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 1011 C6+ ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the 11C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C4+ ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of 11C, transporting to the tumor with the primary accelerated 11C4+ beam, this efficiency is preliminarily considered to be large enough to produce the 11C4+ beam from radioactive methane and to inject this beam into synchrotrons.

  2. STATUS OF ITEP DECABORANE ION SOURCE PROGRAM.

    Energy Technology Data Exchange (ETDEWEB)

    KULEVOY,T.V.; PETRENKO, S.V.; KUIBEDA, R.P.; SELEZNEV, D.N.; KOZLOV, A.V.; STASEVICH, YU.B.; SITNIKOV, A.L.; SHAMAILOV, I.M.; PERSHIN, V.I.; HERSHCOVITCH, A.; JOHNSON, B.M.; GUSHENETS, V.I.; OKS, E.M.; POOLE, H.J.; MASUNOV, E.S.; POLOZOV, S.M.

    2007-08-26

    The joint research and development program is continued to develop steady-state ion source of decaborane beam for ion implantation industry. Both Freeman and Bemas ion sources for decaborane ion beam generation were investigated. Decaborane negative ion beam as well as positive ion beam were generated and delivered to the output of mass separator. Experimental results obtained in ITEP are presented.

  3. An ion trap-ion mobility-time of flight mass spectrometer with three ion sources for ion/ion reactions.

    Science.gov (United States)

    Zhao, Qin; Soyk, Matthew W; Schieffer, Gregg M; Fuhrer, Katrin; Gonin, Marc M; Houk, R S; Badman, Ethan R

    2009-08-01

    This instrument combines the capabilities of ion/ion reactions with ion mobility (IM) and time-of-flight (TOF) measurements for conformation studies and top-down analysis of large biomolecules. Ubiquitin ions from either of two electrospray ionization (ESI) sources are stored in a three dimensional (3D) ion trap (IT) and reacted with negative ions from atmospheric sampling glow discharge ionization (ASGDI). The proton transfer reaction products are then separated by IM and analyzed via a TOF mass analyzer. In this way, ubiquitin +7 ions are converted to lower charge states down to +1; the ions in lower charge states tend to be in compact conformations with cross sections down to approximately 880 A(2). The duration and magnitude of the ion ejection pulse on the IT exit and the entrance voltage on the IM drift tube can affect the measured distribution of conformers for ubiquitin +7 and +6. Alternatively, protein ions are fragmented by collision-induced dissociation (CID) in the IT, followed by ion/ion reactions to reduce the charge states of the CID product ions, thus simplifying assignment of charge states and fragments using the mobility-resolved tandem mass spectrum. Instrument characteristics and the use of a new ion trap controller and software modifications to control the entire instrument are described.

  4. Evaluation of myocardial flow reserve using pharmacological stress thallium-201 single-photon emission computed tomography: is there a difference between total arterial off-pump coronary artery bypass grafting and conventional coronary artery bypass grafting?

    Science.gov (United States)

    Lee, Jae Won; Ryu, Sang Wan; Song, Hyun; Kim, Kyung Sun; Yang, Yu Jung; Moon, Dae Hyeuk

    2004-01-01

    The advantage of total arterial off-pump coronary bypass grafting (OPCAB) over conventional onpump coronary artery bypass grafting with 1 internal thoracic artery and veins (CCAB) in terms of myocardial flow reserve has not been studied. We studied these procedures using thallium- 201 perfusion single-photon emission computed tomography (Tl-201 perfusion SPECT). Between 1997 and 2001, 152 patients were recruited from our database (OPCAB, n = 100; CCAB, n = 52). All patients underwent pharmacological stress Tl-201 perfusion SPECT 3 to 12 months after bypass surgery. Myocardial perfusion was analyzed semiquantitatively with a 5-point scoring system in a 20-segment model (0, normal, to 4, absence of uptake). Summed stress (SSS), rest (SRS), and difference score (SDS) of the entire myocardium as well as average scores (ASS, ARS, ADS) of individual walls (anterior, septal, lateral, and inferior) were compared by Student t test as well as by repeated-measures analysis of variance with Bonferroni correction. The SSS, SRS, and SDS of OPCAB versus those of CCAB were 6.86 +/- 0.72 versus 7.17 +/- 0.92, 3.95 +/- 0.57 versus 3.75 +/- 0.73, and 2.91 +/- 0.47 versus 3.42 +/- 0.74 (P > .05). However, the lateral wall showed lower scores in OPCAB (ASS, 0.18 versus 0.41, P = .015; ARS, 0.12 versus 0.20, P = .168; ADS, 0.06 versus 0.21, P = .031). The septal wall had higher scores in OPCAB (ASS, 0.33 versus 0.12, P = .003; ARS, 0.18 versus 0.07, P = .037; ADS, 0.14 versus 0.04, P = .030). The anterior and inferior walls were not different between the 2 groups. OPCAB led to results similar to those of CCAB. The better results in the lateral wall have been the effect of grafting radial artery rather than vein. The similarity in myocardial reserve in the inferior wall between the 2 groups needs further study. There was no deleterious effect of off-pump as opposed to on-pump CAB.

  5. Electromagnetic ion/ion cyclotron instability - Theory and simulations

    Science.gov (United States)

    Winske, D.; Omidi, N.

    1992-01-01

    Linear theory and 1D and 2D hybrid simulations are employed to study electromagnetic ion/ion cyclotron (EMIIC) instability driven by the relative streaming of two field-aligned ion beams. The characteristics of the instability are studied as a function of beam density, propagation angle, electron-ion temperature ratios, and ion beta. When the propagation angle is near 90 deg the EMIIC instability has the characteristics of an electrostatic instability, while at smaller angles electromagnetic effects play a significant role as does strong beam coupling. The 2D simulations point to a narrowing of the wave spectrum and accompanying coherent effects during the linear growth stage of development. The EMIIC instability is an important effect where ion beta is low such as in the plasma-sheet boundary layer and upstream of slow shocks in the magnetotail.

  6. Ion-water clusters, bulk medium effects, and ion hydration

    CERN Document Server

    Merchant, Safir; Dean, Kelsey R; Asthagiri, D

    2011-01-01

    Thermochemistry of gas-phase ion-water clusters together with estimates of the hydration free energy of the clusters and the water ligands are used to calculate the hydration free energy of the ion. Often the hydration calculations use a continuum model of the solvent. The primitive quasichemical approximation to the quasichemical theory provides a transparent framework to anchor such efforts. Here we evaluate the approximations inherent in the primitive quasichemical approach and elucidate the different roles of the bulk medium. We find that the bulk medium can stabilize configurations of the cluster that are usually not observed in the gas phase, while also simultaneously lowering the excess chemical potential of the ion. This effect is more pronounced for soft ions. Since the coordination number that minimizes the excess chemical potential of the ion is identified as the optimal or most probable coordination number, for such soft ions, the optimum cluster size and the hydration thermodynamics obtained with...

  7. Charge Breeding of Radioactive Ions

    CERN Document Server

    Wenander, F J C

    2013-01-01

    Charge breeding is a technique to increase the charge state of ions, in many cases radioactive ions. The singly charged radioactive ions, produced in an isotope separator on-line facility, and extracted with a low kinetic energy of some tens of keV, are injected into a charge breeder, where the charge state is increased to Q. The transformed ions are either directed towards a dedicated experiment requiring highly charged ions, or post-accelerated to higher beam energies. In this paper the physics processes involved in the production of highly charged ions will be introduced, and the injection and extraction beam parameters of the charge breeder defined. A description of the three main charge-breeding methods is given, namely: electron stripping in gas jet or foil; external ion injection into an electron-beam ion source/trap (EBIS/T); and external ion injection into an electron cyclotron resonance ion source (ECRIS). In addition, some preparatory devices for charge breeding and practical beam delivery aspects ...

  8. Cobalt alloy ion sources for focused ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Muehle, R.; Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Zimmermann, P. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Cobalt alloy ion sources have been developed for silicide formation by focused ion beam implantation. Four eutectic alloys AuCo, CoGe, CoY and AuCoGe were produced by electron beam welding. The AuCo liquid alloy ion source was investigated in detail. We have measured the emission current stability, the current-voltage characteristics, and the mass spectrum as a function of the mission current. (author) 1 fig., 2 refs.

  9. Carbon Ion Therapy

    DEFF Research Database (Denmark)

    Bassler, Niels; Hansen, David Christoffer; Herrmann, Rochus

    On the importance of choice of target size for selective boosting of hypoxic tumor subvolumina in carbon ion therapy Purpose: Functional imaging methods in radiotherapy are maturing and can to some extent uncover radio resistant structures found within a tumour entity. Selective boost of identified...... hypoxic subvolumina with high-LET radiation may in principle lead to increased tumour control due to LET-dependence of the oxygen enhancement ratio (OER). Here, we demonstrate the importance of minimizing field sizes in order not to dilute the dose average LET by quantifying the OER as a function of PTV...

  10. Ion/neutral, ion/electron, ion/photon, and ion/ion interactions in tandem mass spectrometry: do we need them all? Are they enough?

    Science.gov (United States)

    McLuckey, Scott A; Mentinova, Marija

    2011-01-01

    A range of strategies and tools have been developed to facilitate the determination of primary structures of analyte molecules of interest via tandem mass spectrometry (MS/MS). The two main factors that determine the primary structural information present in an MS/MS spectrum are the type of ion generated from the analyte molecule and the dissociation method. The ion type subjected to dissociation is determined by the ionization method/conditions and ion transformation processes that might take place after initial gas-phase ion formation. Furthermore, the range of analyte-related ion types can be expanded via derivatization reactions prior to mass spectrometry. Dissociation methods include those that simply alter the population of internal states of the mass-selected ion (i.e., activation methods like collision-induced dissociation) as well as processes that rely on the transformation of the ion type prior to dissociation (e.g., electron capture dissociation). A variety of ion interactions have been studied for the purpose of ion dissociation and ion transformation, including ion/neutral, ion/photon, ion/electron, and ion/ion interactions. A wide range of phenomena have been observed, many of which have been explored/developed as means for structural analysis. The techniques arising from these phenomena are discussed within the context of the elements of structural determination in tandem mass spectrometry: ion-type definition and dissociation. Unique aspects of the various ion interactions are emphasized along with any barriers to widespread implementation. © American Society for Mass Spectrometry, 2011

  11. A novel planar ion funnel design for miniature ion optics.

    Science.gov (United States)

    Chaudhary, A; van Amerom, Friso H W; Short, R T

    2014-10-01

    The novel planar ion funnel (PIF) design presented in this article emphasizes simple fabrication, assembly, and operation, making it amenable to extreme miniaturization. Simulations performed in SIMION 8.0 indicate that ion focusing can be achieved by using a gradient of electrostatic potentials on concentric metal rings in a plane. A prototype was fabricated on a 35 × 35 mm custom-designed printed circuit board (PCB) with a center hole for ions to pass through and a series of concentric circular metal rings of increasing diameter on the front side of the PCB. Metal vias on the PCB electrically connected each metal ring to a resistive potential divider that was soldered on the back of the PCB. The PIF was tested at 5.5 × 10(-6) Torr in a vacuum test setup that was equipped with a broad-beam ion source on the front and a micro channel plate (MCP) ion detector on the back of the PIF. The ion current recorded on the MCP anode during testing indicated a 23× increase in the ion transmission through the PIF when electric potentials were applied to the rings. These preliminary results demonstrate the functionality of a 2D ion funnel design with a much smaller footprint and simpler driving electronics than conventional 3D ion funnels. Future directions to improve the design and a possible micromachining approach to fabrication are discussed in the conclusions.

  12. Enhanced life ion source for germanium and carbon ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Tseh-Jen; Colvin, Neil; Kondratenko, Serguei [Axcelis Technologies, Inc. 108 Cherry Hill Drive, Beverly, MA 01915 (United States)

    2012-11-06

    Germanium and carbon ions represent a significant portion of total ion implantation steps in the process flow. Very often ion source materials that used to produce ions are chemically aggressive, especially at higher temperatures, and result in fast ion source performance degradation and a very limited lifetime [B.S. Freer, et. al., 2002 14th Intl. Conf. on Ion Implantation Technology Proc, IEEE Conf. Proc., p. 420 (2003)]. GeF{sub 4} and CO{sub 2} are commonly used to generate germanium and carbon beams. In the case of GeF{sub 4} controlling the tungsten deposition due to the de-composition of WF{sub 6} (halogen cycle) is critical to ion source life. With CO{sub 2}, the materials oxidation and carbon deposition must be controlled as both will affect cathode thermionic emission and anti-cathode (repeller) efficiencies due to the formation of volatile metal oxides. The improved ion source design Extended Life Source 3 (Eterna ELS3) together with its proprietary co-gas material implementation has demonstrated >300 hours of stable continuous operation when using carbon and germanium ion beams. Optimizing cogas chemistries retard the cathode erosion rate for germanium and carbon minimizes the adverse effects of oxygen when reducing gas is introduced for carbon. The proprietary combination of hardware and co-gas has improved source stability and the results of the hardware and co-gas development are discussed.

  13. Practical aspects of trapped ion mass spectrometry, 5 applications of ion trapping devices

    CERN Document Server

    March, Raymond E

    2009-01-01

    Examines ion/neutral and ion/ion reactions, ion spectroscopy, and the structural characterization of proteins and peptides using quadropole ion trap mass spectrometry, Fourier transform - ion cyclotron resonance (FT-ICR) mass spectrometry, and traveling wave ion mobility mass spectrometry.

  14. Proton and carbon ion therapy

    CERN Document Server

    Lomax, Tony

    2013-01-01

    Proton and Carbon Ion Therapy is an up-to-date guide to using proton and carbon ion therapy in modern cancer treatment. The book covers the physics and radiobiology basics of proton and ion beams, dosimetry methods and radiation measurements, and treatment delivery systems. It gives practical guidance on patient setup, target localization, and treatment planning for clinical proton and carbon ion therapy. The text also offers detailed reports on the treatment of pediatric cancers, lymphomas, and various other cancers. After an overview, the book focuses on the fundamental aspects of proton and carbon ion therapy equipment, including accelerators, gantries, and delivery systems. It then discusses dosimetry, biology, imaging, and treatment planning basics and provides clinical guidelines on the use of proton and carbon ion therapy for the treatment of specific cancers. Suitable for anyone involved with medical physics and radiation therapy, this book offers a balanced and critical assessment of state-of-the-art...

  15. TOPICAL REVIEW: Highly charged ions

    Science.gov (United States)

    Gillaspy, J. D.

    2001-10-01

    This paper reviews some of the fundamental properties of highly charged ions, the methods of producing them (with particular emphasis on table-top devices), and their use as a tool for both basic science and applied technology. Topics discussed include: charge dependence and scaling laws along isoelectronic or isonuclear sequences (for wavefunction size or Bohr radius, ionization energy, dipole transition energy, relativistic fine structure, hyperfine structure, Zeeman effect, Stark effect, line intensities, linewidths, strength of parity violation, etc), changes in angular momentum coupling schemes, selection rules, interactions with surfaces, electron-impact ionization, the electron beam ion trap (EBIT), ion accelerators, atomic reference data, cosmic chronometers, laboratory x-ray astrophysics, vacuum polarization, solar flares, ion implantation, ion lithography, ion microprobes (SIMS and x-ray microscope), nuclear fusion diagnostics, nanotechnology, quantum computing, cancer therapy and biotechnology.

  16. An ion displacement membrame model.

    Science.gov (United States)

    Hladky, S B; Harris, J D

    1967-09-01

    The usual assumption in treating the diffusion of ions in an electric field has been that the movement of each ion is independent of the movement of the others. The resulting equation for diffusion by a succession of spontaneous jumps has been well stated by Parlin and Eyring. This paper will consider one simple case in which a different assumption is reasonable. Diffusion of monovalent positive ions is considered as a series of jumps from one fixed negative site to another. The sites are assumed to be full (electrical neutrality). Interaction occurs by the displacement of one ion by another. An ion leaves a site if and only if another ion, not necessarily of the same species, attempts to occupy the same site. Flux ratios and net fluxes are given as functions of the electrical potential, concentration ratios, and number of sites encountered in crossing the membrane. Quantitative comparisons with observations of Hodgkin and Keynes are presented.

  17. SUERC AMS ion detection

    Science.gov (United States)

    Maden, C.; Anastasi, P. A. F.; Dougans, A.; Freeman, S. P. H. T.; Kitchen, R.; Klody, G.; Schnabel, C.; Sundquist, M.; Vanner, K.; Xu, S.

    2007-06-01

    In a short time Be, C, Al, Cl, Ca and I accelerator mass spectrometry (AMS) have been established on the National Electrostatics Corporation (NEC) 5 MV pelletron system at the Scottish Universities Environmental Research Centre (SUERC). While summarising the present performance of the system, this report will focus on the details of ion detection, which sample materials are used and the analytical procedures employed for each individual species during routine analysis. All rare isotope detection is with a single flexible detector and ion event analysis system, but switching of analysed species typically requires a detector reconfiguration. Configurations for routine 10Be, 14C, 26Al, 36Cl, 41Ca and 129I detection have been established and will be presented here. Notably, there has proven to be sufficient suppression of the isobaric interferences of 36Cl and 41Ca in the 5+ charge state using an argon gas stripper at a terminal voltage of 5.0 MV to allow for routine analysis of these isotopes.

  18. Electrically switched ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Lilga, M.A. [Pacific Northwest National Lab., Richland, WA (United States); Schwartz, D.T.; Genders, D.

    1997-10-01

    A variety of waste types containing radioactive {sup 137}Cs are found throughout the DOE complex. These waste types include water in reactor cooling basins, radioactive high-level waste (HLW) in underground storage tanks, and groundwater. Safety and regulatory requirements and economics require the removal of radiocesium before these wastes can be permanently disposed of. Electrically Switched Ion Exchange (ESIX) is an approach for radioactive cesium separation that combines IX and electrochemistry to provide a selective, reversible, and economic separation method that also produces little or no secondary waste. In the ESIX process, an electroactive IX film is deposited electrochemically onto a high-surface area electrode, and ion uptake and elution are controlled directly by modulating the potential of the film. For cesium, the electroactive films under investigation are ferrocyanides, which are well known to have high selectivities for cesium in concentrated sodium solutions. When a cathode potential is applied to the film, Fe{sup +3} is reduced to the Fe{sup +2} state, and a cation must be intercalated into the film to maintain charge neutrality (i.e., Cs{sup +} is loaded). Conversely, if an anodic potential is applied, a cation must be released from the film (i.e., Cs{sup +} is unloaded). Therefore, to load the film with cesium, the film is simply reduced; to unload cesium, the film is oxidized.

  19. Highly Stripped Ion Sources for MeV Ion Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, Ady

    2009-06-30

    Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high

  20. Ion beam assisted film growth

    CERN Document Server

    Itoh, T

    2012-01-01

    This volume provides up to date information on the experimental, theoretical and technological aspects of film growth assisted by ion beams.Ion beam assisted film growth is one of the most effective techniques in aiding the growth of high-quality thin solid films in a controlled way. Moreover, ion beams play a dominant role in the reduction of the growth temperature of thin films of high melting point materials. In this way, ion beams make a considerable and complex contribution to film growth. The volume will be essential reading for scientists, engineers and students working in thi

  1. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    A nanogan type of ECR source based on a fully permanent magnet design was chosen for this purpose [3]. The ECR ion source along with all its peripheral electron- ics and vacuum components placed on a 200 kV high voltage platform provides multiply charged positive ions in a widely varying energy range from a few ...

  2. Energy landscapes for mobile ions in ion conducting solids

    Indian Academy of Sciences (India)

    demonstrated here for a range of metaphosphate and diborate glasses, the complete description of the energy landscape for mobile ions also provides an effective tool for achieving a more detailed understanding of ion transport in glasses. The investigation of time evolutions can be included, if the bond valence analysis is ...

  3. Cold atomic beam ion source for focused ion beam applications

    Energy Technology Data Exchange (ETDEWEB)

    Knuffman, B.; Steele, A. V. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Maryland Nanocenter, University of Maryland, College Park, Maryland 20742 (United States); zeroK NanoTech, Montgomery Village, Maryland 20886 (United States); McClelland, J. J. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States)

    2013-07-28

    We report measurements and modeling of an ion source that is based on ionization of a laser-cooled atomic beam. We show a high brightness and a low energy spread, suitable for use in next-generation, high-resolution focused ion beam systems. Our measurements of total ion current as a function of ionization conditions support an analytical model that also predicts the cross-sectional current density and spatial distribution of ions created in the source. The model predicts a peak brightness of 2 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1} and an energy spread less than 0.34 eV. The model is also combined with Monte-Carlo simulations of the inter-ion Coulomb forces to show that the source can be operated at several picoamperes with a brightness above 1 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1}. We estimate that when combined with a conventional ion focusing column, an ion source with these properties could focus a 1 pA beam into a spot smaller than 1 nm. A total current greater than 5 nA was measured in a lower-brightness configuration of the ion source, demonstrating the possibility of a high current mode of operation.

  4. Ion trajectories in atom probe field ion microscopy and gas field ion sources

    CERN Document Server

    Castilho, C M C

    1999-01-01

    Trajectories of positive ions produced in a region close to a structured surface, modelled by spherical or spheroidal protrusions and kept at a positive electric potential with respect to a distant screen or detector are calculated. The results are discussed in comparison with similar practical situations produced by field ionization and field evaporation or desorption, such as those occurring in gas field ion sources, field ion microscopy and field desorption spectroscopy. (author)

  5. LEXUS heavy ion collisions

    CERN Document Server

    Sang Yong Jeon

    1997-01-01

    We use a Glauber-like approach to describe very energetic nucleus- nucleus collisions as a sequence of binary nucleon-nucleon collisions. No free parameters are needed: all the information comes from simple parametrizations of nucleon-nucleon collision data. Produced mesons are assumed not to interact with each other or with the original baryons. Comparisons are made to published experimental measurements of baryon rapidity and transverse momentum distributions, negative hadron rapidity and transverse momentum distributions, average multiplicities of pions, kaons, hyperons, and antihyperons, and zero degree energy distributions for sulfur-sulfur collisions at 200 GeV/c per nucleon and for lead-lead collisions at 158 GeV/c per nucleon. Good agreement is found except that the number of strange particles produced, especially antihyperons, is too small compared with experiment. We call this model LEXUS: Linear EXtrapolation of Ultrarelativistic nucleon-nucleon Scattering to heavy ion collisions. (11 refs).

  6. Optical Barium Ion Qubit

    CERN Document Server

    Yum, Dahyun; Dutta, Tarun; Mukherjee, Manas

    2016-01-01

    We demonstrate an optical single qubit based on 6S1/2 to 5D5/2 quadrupole transition of a single Ba+ ion operated by diode based lasers only. The resonance wavelength of the 6S1/2 to 5D5/2 quadrupole transition is about 1762 nm which suitably falls close to the U-band of the telecommunication wavelength. Thus this qubit is a naturally attractive choice towards implementation of quantum repeater or quantum networks using existing telecommunication networks. We observe continuous bit-flip oscillations at a rate of about 250 kHz which is fast enough for the qubit operation as compared to the measured coherence time of over 3 ms. We also present a technique to quantify the bit-flip error in each qubit NOT gate operation.

  7. Fast ion atomic spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Berry, H.G.; Young, L.; Goodman, L.S.; Somerville, L.P.; Hardis, J.; Neek, D.

    1984-01-01

    We have set up two collinear fast beam/laser excitation systems, one at the Argonne Dynamitron Accelerator (0.5 to 5.0 MeV beam energy) and another at a small electrostatic accelerator (20 to 130 keV). Our objective is to study fine structure, hyperfine structure and QED effects in ions of a few electrons. Initial projects underway include studies of multi-excited transitions in Li/sup -/ and Li/sup 0/, and transitions to high Rydberg states in H/sup 0/ and He/sup 0/. We have simultaneously excited a sodium jet with a laser at the resonance wavelength (D/sub 1/ or D/sub 2/ lines) and a 1-MeV He/sup +/ beam to produce excitation to autoionizing Na and Na/sup +/ states. The Auger electron spectra are compared to spectra obtained without laser excitation, and indicate strong variations in final state populations. 17 references.

  8. Ion-conducting membranes

    Energy Technology Data Exchange (ETDEWEB)

    Masel, Richard L.; Chen, Qingmei; Liu, Zengcai; Kutz, Robert

    2016-06-21

    An ion conducting polymeric composition mixture comprises a copolymer of styrene and vinylbenzyl-R.sub.s. R.sub.s is selected from the group consisting of imidazoliums and pyridiniums. The composition contains 10%-90% by weight of vinylbenzyl-R.sub.s. The composition can further comprise a polyolefin comprising substituted polyolefins, a polymer comprising cyclic amine groups, a polymer comprising at least one of a phenylene group and a phenyl group, a polyamide, and/or the reaction product of a constituent having two carbon-carbon double bonds. The composition can be in the form of a membrane. In a preferred embodiment, the membrane is a Helper Membrane that increases the faradaic efficiency of an electrochemical cell into which the membrane is incorporated, and also allows product formation at lower voltages than in cells without the Helper Membrane.

  9. Miniature Lightweight Ion Pump

    Science.gov (United States)

    Sinha, Mahadeva P.

    2010-01-01

    This design offers a larger surface area for pumping of active gases and reduces the mass of the pump by eliminating the additional vacuum enclosure. There are three main components to this ion pump: the cathode and anode pumping elements assembly, the vacuum enclosure (made completely of titanium and used as the cathode and maintained at ground potential) containing the assembly, and the external magnet. These components are generally put in a noble diode (or differential) configuration of the ion pump technology. In the present state of the art, there are two cathodes, one made of titanium and the other of tantalum. The anodes are made up of an array of stainless steel cylinders positioned between the two cathodes. All the elements of the pump are in a vacuum enclosure. After the reduction of pressure in this enclosure to a few microns, a voltage is applied between the cathode and the anode elements. Electrons generated by the ionization are accelerated toward the anodes that are confined in the anode space by the axial magnetic field. For the generation of the axial field along the anode elements, the magnet is designed in a C-configuration and is fabricated from rare earth magnetic materials (Nd-B-Fe or Sm-Co) possessing high energy product values, and the yoke is fabricated from the high permeability material (Hiperco-50A composed of Fe-Co-V). The electrons in this region collide with the gas molecules and generate their positive ions. These ions are accelerated into the cathode and eject cathode material (Ti). The neutral atoms deposit on the anode surfaces. Because of the chemical activity of Ti, the atoms combine with chemically active gas molecules (e.g. N2, O2, etc.) and remove them. New layers of Ti are continually deposited, and the pumping of active gases is thus accomplished. Pumping of the inert gases is accomplished by their burial several atomic layers deep into the cathode. However, they tend to re-emit if the entrapping lattice atoms are

  10. Ion-conducting membranes

    Energy Technology Data Exchange (ETDEWEB)

    Masel, Richard I.; Chen, Qingmei; Liu, Zengcai; Kutz, Robert

    2017-02-28

    An ion conducting polymeric composition mixture comprises a copolymer of styrene and vinylbenzyl-R.sub.s. R.sub.s is selected from the group consisting of imidazoliums, pyridiniums, pyrazoliums, pyrrolidiniums, pyrroliums, pyrimidiums, piperidiniums, indoliums, and triaziniums. The composition contains 10%-90% by weight of vinylbenzyl-R.sub.s. The composition can further comprise a polyolefin comprising substituted polyolefins, a polymer comprising cyclic amine groups, a polymer comprising at least one of a phenylene group and a phenyl group, a polyamide, and/or the reaction product of a constituent having two carbon-carbon double bonds. The composition can be in the form of a membrane. In a preferred embodiment, the membrane is a Helper Membrane that increases the faradaic efficiency of an electrochemical cell into which the membrane is incorporated, and also allows product formation at lower voltages than in cells without the Helper Membrane.

  11. Ion beams in materials processing and analysis

    CERN Document Server

    Schmidt, Bernd

    2012-01-01

    This book covers ion beam application in modern materials research, offering the basics of ion beam physics and technology and a detailed account of the physics of ion-solid interactions for ion implantation, ion beam synthesis, sputtering and nano-patterning.

  12. Holifield heavy ion research facility

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.; Alton, G.D.; Ball, J.B.; Biggerstaff, J.A.; Dowling, D.T.; Erb, K.A.; Haynes, D.L.; Hoglund, D.E.; Hudson, E.D.; Juras, R.C.

    1988-05-20

    Development of the Holifield facility has continued with resulting improvements in the number of ion species provided, in the ion energy for tandem-only operations, and in utilization efficiency. In this report, we describe our recent operational experience, development activities, and future development plans.

  13. Propagation of Ion Acoustic Perturbations

    DEFF Research Database (Denmark)

    Pécseli, Hans

    1975-01-01

    Equations describing the propagation of ion acoustic perturbations are considered, using the assumption that the electrons are Boltzman distributed and isothermal at all times. Quasi-neutrality is also considered.......Equations describing the propagation of ion acoustic perturbations are considered, using the assumption that the electrons are Boltzman distributed and isothermal at all times. Quasi-neutrality is also considered....

  14. High Resolution Scanning Ion Microscopy

    NARCIS (Netherlands)

    Castaldo, V.

    2011-01-01

    The structure of the thesis is the following. The first chapter is an introduction to scanning microscopy, where the path that led to the Focused Ion Beam (FIB) is described and the main differences between electrons and ion beams are highlighted. Chapter 2 is what is normally referred to (which I

  15. Quantum computing with trapped ions

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, R.J.

    1998-01-01

    The significance of quantum computation for cryptography is discussed. Following a brief survey of the requirements for quantum computational hardware, an overview of the ion trap quantum computation project at Los Alamos is presented. The physical limitations to quantum computation with trapped ions are analyzed and an assessment of the computational potential of the technology is made.

  16. SPS Ion Induced Desorption Experiment

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    This experiment will give a study about the induced desorption from heavy ion (Indium ion run from week 45 in SPS T4-H8 area) impacting LHC type graphite collimator. 4 different samples are located in the 4 chambers 90° one to each other: pure graphite, graphite with copper coating, graphite with NEG coating, 316LN stainless steal (reference).

  17. Bundle Security Protocol for ION

    Science.gov (United States)

    Burleigh, Scott C.; Birrane, Edward J.; Krupiarz, Christopher

    2011-01-01

    This software implements bundle authentication, conforming to the Delay-Tolerant Networking (DTN) Internet Draft on Bundle Security Protocol (BSP), for the Interplanetary Overlay Network (ION) implementation of DTN. This is the only implementation of BSP that is integrated with ION.

  18. Lithium ion storage between graphenes

    Directory of Open Access Journals (Sweden)

    Chan Yue

    2011-01-01

    Full Text Available Abstract In this article, we investigate the storage of lithium ions between two parallel graphene sheets using the continuous approximation and the 6-12 Lennard-Jones potential. The continuous approximation assumes that the carbon atoms can be replaced by a uniform distribution across the surface of the graphene sheets so that the total interaction potential can be approximated by performing surface integrations. The number of ion layers determines the major storage characteristics of the battery, and our results show three distinct ionic configurations, namely single, double, and triple ion forming layers between graphenes. The number densities of lithium ions between the two graphenes are estimated from existing semi-empirical molecular orbital calculations, and the graphene sheets giving rise to the triple ion layers admit the largest storage capacity at all temperatures, followed by a marginal decrease of storage capacity for the case of double ion layers. These two configurations exceed the maximum theoretical storage capacity of graphite. Further, on taking into account the charge-discharge property, the double ion layers are the most preferable choice for enhanced lithium storage. Although the single ion layer provides the least charge storage, it turns out to be the most stable configuration at all temperatures. One application of the present study is for the design of future high energy density alkali batteries using graphene sheets as anodes for which an analytical formulation might greatly facilitate rapid computational results.

  19. Anisotropic water reorientation around ions

    NARCIS (Netherlands)

    Tielrooij, K.J.; van der Post, S.T.; Hunger, J.; Bonn, M.; Bakker, H.J.

    2011-01-01

    We study the reorientation dynamics of water molecules around ions using terahertz dielectric relaxation spectroscopy and polarization-resolved femtosecond infrared pump-probe spectroscopy. The results are discussed in relation to the ion-specific Hofmeister series and the concomitant

  20. Nanofriction in cold ion traps.

    Science.gov (United States)

    Benassi, A; Vanossi, A; Tosatti, E

    2011-01-01

    Sliding friction between crystal lattices and the physics of cold ion traps are so far non-overlapping fields. Two sliding lattices may either stick and show static friction or slip with dynamic friction; cold ions are known to form static chains, helices or clusters, depending on the trapping conditions. Here we show, based on simulations, that much could be learnt about friction by sliding, through, for example, an electric field, the trapped ion chains over a corrugated potential. Unlike infinite chains, in which the theoretically predicted Aubry transition to free sliding may take place, trapped chains are always pinned. Yet, a properly defined static friction still vanishes Aubry-like at a symmetric-asymmetric structural transition, found for decreasing corrugation in both straight and zig-zag trapped chains. Dynamic friction is also accessible in ringdown oscillations of the ion trap. Long theorized static and dynamic one-dimensional friction phenomena could thus become accessible in future cold ion tribology.

  1. Logic gates with ion transistors

    Science.gov (United States)

    Grebel, H.

    2017-09-01

    Electronic logic gates are the basic building blocks of every computing and micro controlling system. Logic gates are made of switches, such as diodes and transistors. Ion-selective, ionic switches may emulate electronic switches [1-8]. If we ever want to create artificial bio-chemical circuitry, then we need to move a step further towards ion-logic circuitry. Here we demonstrate ion XOR and OR gates with electrochemical cells, and specifically, with two wet-cell batteries. In parallel to vacuum tubes, the batteries were modified to include a third, permeable and conductive mid electrode (the gate), which was placed between the anode and cathode in order to affect the ion flow through it. The key is to control the cell output with a much smaller biasing power, as demonstrated here. A successful demonstration points to self-powered ion logic gates.

  2. The ATLAS positive ion injector

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.; Bollinger, L.M.; Pardo, R.C.

    1990-01-01

    This paper reviews the design, construction status, and beam tests to date of the positive ion injector (PII) which is replacing the tandem injector for the ATLAS heavy-ion facility. PII consists of an ECR ion source on a 350 KV platform injecting a very low velocity superconducting linac. The linac is composed of an independently-phased array of superconducting four-gap interdigital resonators which accelerate over a velocity range of .006 to .05c. In finished form, PII will be able to inject ions as heavy as uranium into the existing ATLAS linac. Although at the present time little more than 50% of the linac is operational, the indenpently-phased array is sufficiently flexible that ions in the lower half of the periodic table can be accelerated and injected into ATLAS. Results of recent operational experience will be discussed. 5 refs.

  3. Logic Gates with Ion Transistors

    CERN Document Server

    Grebel, Haim

    2016-01-01

    Electronic logic gates are the basic building blocks of every computing and micro controlling system. Logic gates are made of switches, such as diodes and transistors. Ion-selective, ionic switches may emulate electronic switches [1-8]. If we ever want to create artificial bio-chemical circuitry, then we need to move a step further towards ion-logic circuitry. Here we demonstrate ion XOR and OR gates with electrochemical cells, and specifically, with two wet-cell batteries. In parallel to vacuum tubes, the batteries were modified to include a third, permeable and conductive mid electrode (the gate), which was placed between the anode and cathode in order to affect the ion flow through it. The key is to control the cell output with a much smaller biasing power, as demonstrated here. A successful demonstration points to self-powered ion logic gates.

  4. Ion-Molecule Reaction Dynamics.

    Science.gov (United States)

    Meyer, Jennifer; Wester, Roland

    2017-05-05

    We review the recent advances in the investigation of the dynamics of ion-molecule reactions. During the past decade, the combination of single-collision experiments in crossed ion and neutral beams with the velocity map ion imaging detection technique has enabled a wealth of studies on ion-molecule reactions. These methods, in combination with chemical dynamics simulations, have uncovered new and unexpected reaction mechanisms, such as the roundabout mechanism and the subtle influence of the leaving group in anion-molecule nucleophilic substitution reactions. For this important class of reactions, as well as for many fundamental cation-molecule reactions, the information obtained with crossed-beam imaging is discussed. The first steps toward understanding micro-solvation of ion-molecule reaction dynamics are presented. We conclude with the presentation of several interesting directions for future research.

  5. Ions kinematics in an electrostatic ion beam trap

    Energy Technology Data Exchange (ETDEWEB)

    Attia, D

    2004-06-01

    In this study, I have tried to provide a better understanding of the dynamics of ions inside an electrostatic ion beam trap. The electrostatic ion trap allows to store ions moving between two electrostatic mirrors. Although the trap has been developed already seven years ago, no direct measurement of the transversal velocity distribution of the ions has been performed. Such quantity is central for understanding the conditions under which a beam should be produced (mainly emittance) in order to be trapped by such a device. The data I have obtained during the course of this work are based on an experimental technique which relies on the direct imaging of the particles exiting the trap, as well as on numerical simulations of the ion trajectories inside the trap. I have personally been involved in the hardware development of the imaging system, the data acquisition and analysis of the data as well as il all numerical calculations presented here. These results allow us to obtain, for the first time, experimental information on the transverse phase space of the trap, and contribute to the overall understanding of the ion motion in this system. (author)

  6. Ion Rings for Magnetic Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Greenly, John, B.

    2005-07-31

    This Final Technical Report presents the results of the program, Ion Rings for Magnetic Fusion, which was carried out under Department of Energy funding during the period August, 1993 to January, 2005. The central objective of the program was to study the properties of field-reversed configurations formed by ion rings. In order to reach this objective, our experimental program, called the Field-reversed Ion Ring Experiment, FIREX, undertook to develop an efficient, economical technology for the production of field-reversed ion rings. A field-reversed configuration (FRC) in which the azimuthal (field-reversing) current is carried by ions with gyro-radius comparable to the magnetic separatrix radius is called a field-reversed ion ring. A background plasma is required for charge neutralization of the ring, and this plasma will be confined within the ring's closed magnetic flux. Ion rings have long been of interest as the basis of compact magnetic fusion reactors, as the basis for a high-power accelerator for an inertial fusion driver, and for other applications of high power ion beams or plasmas of high energy density. Specifically, the FIREX program was intended to address the longstanding question of the contribution of large-orbit ions to the observed stability of experimental FRCs to the MHD tilt mode. Typical experimental FRCs with s {approx} 2-4, where s is the ratio of separatrix radius to ion gyro-radius, have been stable to tilting, but desired values for a fusion reactor, s > 20, should be unstable. The FIREX ring would consist of a plasma with large s for the background ions, but with s {approx} 1 for the ring ions. By varying the proportions of these two populations, the minimum proportion of large-orbit ions necessary for stability could be determined. The incorporation of large-orbit ions, perhaps by neutral-beam injection, into an FRC has been advanced for the purpose of stabilizing, heating, controlling angular momentum, and aiding the formation

  7. Data acquisition for the HILI (Heavy Ion Light Ion) detector

    Energy Technology Data Exchange (ETDEWEB)

    Teh, K.M.; Shapira, D.; McConnell, J.W.; Kim, H.; Novotny, R.

    1987-01-01

    A large acceptance, multi-segmented detector system capable of the simultaneous detection of heavy and light ions has been constructed. The heavy ions are detected with a segmented gas ionization chamber and a multiwire proportional counter while the light ions are detected with a 192 element plastic phoswich hodoscope. Processing the large number of signals is accomplished through a combination of CAMAC and FASTBUS modules and preprocessors, and a Host minicomputer. Details of the data acquisition system and the reasons for adopting a dual standards system are discussed. In addition, a technique for processing signals from an individual hodoscope detector is presented. 4 refs., 3 figs.

  8. Ion beam analysis of metal ion implanted surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P.J.; Chu, J.W.; Johnson, E.P.; Noorman, J.T. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Sood, D.K. [Royal Melbourne Inst. of Tech., VIC (Australia)

    1993-12-31

    Ion implantation is an established method for altering the surface properties of many materials. While a variety of analytical techniques are available for the characterisation of implanted surfaces, those based on particle accelerators such as Rutherford backscattering (RBS) and nuclear reaction analysis (NRA) provide some of the most useful and powerful for this purpose. Application of the latter techniques to metal ion implantation research at ANSTO will be described with particular reference to specific examples from recent studies. Where possible, the information obtained from ion beam analysis will be compared with that derived from other techniques such as Energy Dispersive X-ray (EDX) and Auger spectroscopies. 4 refs., 5 figs.

  9. High Current Ion Sources and Injectors for Heavy Ion Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Kwan, Joe W.

    2005-02-15

    Heavy ion beam driven inertial fusion requires short ion beam pulses with high current and high brightness. Depending on the beam current and the number of beams in the driver system, the injector can use a large diameter surface ionization source or merge an array of small beamlets from a plasma source. In this paper, we review the scaling laws that govern the injector design and the various ion source options including the contact ionizer, the aluminosilicate source, the multicusp plasma source, and the MEVVA source.

  10. Rearrangement reactions in ion-ion and ion-atom collisions: results and problems

    Energy Technology Data Exchange (ETDEWEB)

    Presnyakov, L.P. [Lebedev Physical Institute, Moscow (Russian Federation); Tawara, H.

    1997-01-01

    Recent experimental and theoretical results are discussed for ionic collisions with large cross sections at intermediate and small energies of the relative motion. Single- and double-electron removal from H{sup -} ions in slow collisions with other ions is considered in more details. The theoretical methods are discussed from the viewpoint of general requirements of scattering theory. (author)

  11. Three-dimensional simulations of ion dynamics in an Electron Cyclotron Resonance Ion Source

    NARCIS (Netherlands)

    Beijers, J. P. M.; Mironov, V.

    We present a three-dimensional simulation of the ion dynamics in an electron cyclotron resonance ion source. Ion trajectories in the min-B field of the source are calculated taking ion-ion and electron-ion collisions into account. The electrons are not tracked but considered as a neutralizing

  12. Behavior of Time-Resolved Ion Energy Distribution Functions during Ion-Ion Instability

    Science.gov (United States)

    Saitou, Yoshifumi; Nakamura, Yoshiharu; Tanaka, Masayoshi; Komori, Akio; Kawai, Yoshinobu

    1993-10-01

    When an external RF field is applied to an ion beam plasma system, ion-ion instability is suppressed at f/fii≳1, where f and fii are the frequency of the external RF field and the peak frequency of the instability, respectively. It is also observed that the time-averaged energy distribution function of the ion beam broadens when the instability is suppressed. In order to investigate the cause of this broadening, time-resolved energy distribution functions of ions are measured with a boxcar integrator. As a result, it is found that the energy distribution functions periodically change with the external RF field and the above broadening is apparently caused by the time-averaging of the energy distribution functions.

  13. Characteristics of photoconductivity in thallium monosulfide single ...

    Indian Academy of Sciences (India)

    Pramana – Journal of Physics. Current Issue : Vol. 90, Issue 1 · Current Issue Volume 90 | Issue 1. January 2018. Home · Volumes & Issues · Special Issues · Forthcoming Articles · Search · Editorial Board · Information for Authors · Subscription ...

  14. Triple ion beam irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, M.B.; Allen, W.R.; Buhl, R.A.; Packan, N.H.; Cook, S.W.; Mansur, L.K.

    1988-12-01

    A unique ion irradiation facility consisting of three accelerators is described. The accelerators can be operated simultaneously to deliver three ion beams on one target sample. The energy ranges of the ions are 50 to 400 keV, 200 keV to 2.5 MeV, and 1.0 to 5.0 MeV. Three different ions in the appropriate mass range can be simultaneously implanted to the same depth in a target specimen as large as 100 mm/sup 2/ in area. Typical depth ranges are 0.1 to 1.0 ..mu..m. The X-Y profiles of all three ion beams are measured by a system of miniature Faraday cups. The low-voltage accelerator can periodically ramp the ion beam energy during the implantation. Three different types of target chambers are in use at this facility. The triple-beam high-vacuum chamber can hold nine transmission electron microscopy specimens at elevated temperature during a irradiation by the three simultaneous beams. A second high-vacuum chamber on the medium-voltage accelerator beamline houses a low- and high-temperature translator and a two-axis goniometer for ion channeling measurements. The third chamber on the high-energy beamline can be gas-filled for special stressed specimen irradiations. Special applications for the surface modification of materials with this facility are described. Appendixes containing operating procedures are also included. 18 refs., 27 figs., 1 tab.

  15. DIVALENT ION EXCHANGE WITH ALKALI

    Energy Technology Data Exchange (ETDEWEB)

    Bunge, A.L.; Klein, G.; Radke, C.J.

    1980-05-01

    Exchange of hardness ions is important in enhanced oil recovery with chemical additives. In both micellar-polymer and caustic flooding processes, multivalent ions released from rock surfaces can interact with anionic surfactants, rendering them preferentially oil soluble and/or insoluble in water. Because hardness cations are sparingly soluble and precipitate in alkaline solutions, such solutions may be more efficient as surfactant flood preflushes than are softened brines. Multivalent ion precipitation may also occur in alkaline waterflooding. To permit design of such processes, this paper presents a chromatographic theory for simultaneous ion exchange with precipitation of divalent ions. Theoretical effluent histories and concentration profiles are presented for the cases of finite pulses and continuous injection of hydroxide ions into linear cores. Complete capture of the insoluble salt particles is assumed. Results are given for the case of instantaneous equilibration of the solution with the precipitate, as well for the case of complete nonequilibrium, in which the solid precipitate does not redissolve. The efficiency of alklaine preflushing is shown to depend on the exchange isotherm, initial divalent loading of the rock, injected pH and salinity, the solubility product of the precipitated salt, and pulse size. The effect of slug size on complete equilibrium removal of hardness ions is reduced efficiency with increasing size until a critical volume approximating continuous injection is reached. Increasing injected pH and salinity provides a more favorable response. Experimental data for Berea sandstone and an argillaceous sand compare favorably with the proposed theory.

  16. Electrically Switched Cesium Ion Exchange

    Energy Technology Data Exchange (ETDEWEB)

    JPH Sukamto; ML Lilga; RK Orth

    1998-10-23

    This report discusses the results of work to develop Electrically Switched Ion Exchange (ESIX) for separations of ions from waste streams relevant to DOE site clean-up. ESIX combines ion exchange and electrochemistry to provide a selective, reversible method for radionuclide separation that lowers costs and minimizes secondary waste generation typically associated with conventional ion exchange. In the ESIX process, an electroactive ion exchange film is deposited onto. a high surface area electrode, and ion uptake and elution are controlled directly by modulating the potential of the film. As a result, the production of secondary waste is minimized, since the large volumes of solution associated with elution, wash, and regeneration cycles typical of standard ion exchange are not needed for the ESIX process. The document is presented in two parts: Part I, the Summary Report, discusses the objectives of the project, describes the ESIX concept and the approach taken, and summarizes the major results; Part II, the Technology Description, provides a technical description of the experimental procedures and in-depth discussions on modeling, case studies, and cost comparisons between ESIX and currently used technologies.

  17. Ultrarelativistic heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, H.G.

    1980-12-01

    Studies with ultrarelativistic heavy ions combine aspects of cosmic ray physics, particle physics, nuclear physics, astrophysics and cosmogenesis. The leading theoretical concerns are the behavior of matter at very high-energy density and flux, the general behavior of space time in collisions, relativistic nuclear theory, and quantum chromodynamics. The field has developed over a period of more than thirty years, since the first observation of heavy nuclei in cosmic rays and the major developments of understanding of high-energy collisions made by Fermi and Landau in the early fifties. In the late sixties the discovery of the parton content of nucleons was rapidly followed by a great extension of high-energy collision phenomenology at the CERN ISR and subsequent confirmation of the QCD theory. In parallel the study of p-nucleus and nucleus-nucleus collisions at very high energies, especially at the CERN PS, Fermilab and the Bevalac, and in cosmic rays demonstrated that studies involving the nucleus opened up a new dimension in studies of the hadronic interaction. It is now at a high level of interest on an international scale, with major new accelerators being proposed to dedicate to this kind of study.

  18. LHC Report: Ion Age

    CERN Multimedia

    John Jowett for the LHC team

    2013-01-01

    The LHC starts the New Year facing a new challenge: proton-lead collisions in the last month before the shutdown in mid-February.    Commissioning this new and almost unprecedented mode of collider operation is a major challenge both for the LHC and its injector chain. Moreover, it has to be done very quickly to achieve a whole series of physics goals, requiring modifications of the LHC configuration, in a very short time. These include a switch of the beam directions halfway through the run, polarity reversals of the ALICE spectrometer magnet and Van der Meer scans.    The Linac3 team kept the lead source running throughout the end-of-year technical stop, and recovery of the accelerator complex was very quick. New proton and lead beams were soon ready, with a bunch filling pattern that ensures they will eventually match up in the LHC. The LEIR machine has even attained a new ion beam intensity record.  On Friday 11 January the first single bunches o...

  19. Laser induced fluorescence of trapped molecular ions

    Energy Technology Data Exchange (ETDEWEB)

    Grieman, F.J.

    1979-10-01

    An experimental apparatus for obtaining the optical spectra of molecular ions is described. The experimental technique includes the use of three dimensional ion trapping, laser induced fluorescence, and gated photon counting methods. The ions, which are produced by electron impact, are confined in a radio-frequency quadrupole ion trap of cylindrical design. Because the quadrupole ion trap allows mass selection of the molecular ion desired for study, the analysis of the spectra obtained is greatly simplified. The ion trap also confines the ions to a region easily probed by a laser beam. 18 references.

  20. Ion Exchange and Liquid Column Chromatography.

    Science.gov (United States)

    Walton, Harold F.

    1980-01-01

    Emphasizes recent advances in principles and methodology in ion exchange and chromatography. Two tables list representative examples for inorganic ions and organic compounds. Cites 544 references. (CS)

  1. Plasma ion sources and ion beam technology inmicrofabrications

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Lili [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 μm-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance (25

  2. Ion guiding in alumina capillaries

    DEFF Research Database (Denmark)

    Juhász, Z.; Sulik, B.; Biri, S.

    2009-01-01

    Transmission of a few keV impact energy Ne ions through capillaries in anodic alumina membranes has been studied with different ion counting methods using an energy dispersive electrostatic spectrometer, a multichannel plate (MCP) array and sensitive current-measurement. In the present work, we...... focus our attention to the measurements with the MCP array. The alumina capillaries were prepared by electro-chemical oxidation of aluminium foils. For the present experiments guiding of 3-6 keV Ne ions has been studied in two samples with capillary diameter of about 140 nm and 260 nm and with capillary...

  3. Intermediate ions in the atmosphere

    Science.gov (United States)

    Tammet, Hannes; Komsaare, Kaupo; Hõrrak, Urmas

    2014-01-01

    Intermediate air ions are charged nanometer-sized aerosol particles with an electric mobility of about 0.03-0.5 cm2 V- 1 s- 1 and a diameter of about 1.5-7.5 nm. Intensive studies of new particle formation provided good knowledge about intermediate ions during burst events of atmospheric aerosol nucleation. Information about intermediate ions during quiet periods between the bursts remained poor. The new mobility analyzer SIGMA can detect air ions at concentrations of mobility fractions of about 1 cm- 3 and enables studying intermediate ions during quiet periods. It became evident that intermediate ions always exist in atmospheric air and should be considered an indicator and a mediator of aerosol nucleation. The annual average concentration of intermediate ions of one polarity in Tartu, Estonia, was about 40 cm- 3 while 5% of the measurements showed a concentration of less than 10 cm- 3. The fraction concentrations in logarithmic 1/8-decade mobility bins between 0.1 and 0.4 cm2 V- 1 s- 1 often dropped below 1 cm- 3. The bursts of intermediate ions at stations separated by around 100 km appeared to be correlated. The lifespan of intermediate ions in the atmosphere is a few minutes, and they cannot be carried by wind over long distances. Thus the observed long-range correlation of intermediate ions is explained by simultaneous changes in air composition in widely spaced stations. A certain amount of intermediate ion bursts, predominantly of negative polarity, are produced by the balloelectric effect at the splashing of water drops during rain. These bursts are usually excluded when speaking about new particle formation because the balloelectric particles are assumed not to grow to the size of the Aitken mode. The mobility distribution of balloelectric ions is uniform in shape in all measurements. The maximum is located at a mobility of about 0.2 cm2 V- 1 s- 1, which corresponds to the diameter of particles of about 2.5 nm.

  4. The emerging role of ion/ion reactions in biological mass spectrometry: considerations for reagent ion selection.

    Science.gov (United States)

    McLuckey, Scott A

    2010-01-01

    The advent of ionization methods that can produce multiply charged gaseous ions has enabled the development of gas-phase ion/ion reactions in analytical mass spectrometry. Ion/ion chemistry has proved to be a particularly effective means for converting ions from one type to another and allows for a decoupling of the ionization method from the nature of the ion subjected to tandem mass spectrometry. A growing array of applications has been developed based on a variety of reaction types, including electron transfer, proton transfer, charge inversion, metal transfer, etc. Most ion/ion reactions take place following the formation of a stable bound orbit between the reactants. As reactants approach closely enough for chemistry to occur, they can react by small charged particle transfer (i.e. electron transfer and proton transfer) at crossing points in the interaction potential. Alternatively, the reactants can collide to form a relatively long-lived complex. A wide range of chemical reactions can result from the long-lived complex, which include multiple charged particle transfers and covalent bond formation. For a given analyte ion, the major reaction pathway is determined by the characteristics of the reagent ion. An appreciation of the factors that underlie the partitioning of ion/ion reaction products is important in the design and selection of reagent ions to effect transformations of interest. Important considerations for reagent ion selection are discussed here within the context of a generalized scheme for ion/ion reaction dynamics.

  5. Fully variational average atom model with ion-ion correlations.

    Science.gov (United States)

    Starrett, C E; Saumon, D

    2012-02-01

    An average atom model for dense ionized fluids that includes ion correlations is presented. The model assumes spherical symmetry and is based on density functional theory, the integral equations for uniform fluids, and a variational principle applied to the grand potential. Starting from density functional theory for a mixture of classical ions and quantum mechanical electrons, an approximate grand potential is developed, with an external field being created by a central nucleus fixed at the origin. Minimization of this grand potential with respect to electron and ion densities is carried out, resulting in equations for effective interaction potentials. A third condition resulting from minimizing the grand potential with respect to the average ion charge determines the noninteracting electron chemical potential. This system is coupled to a system of point ions and electrons with an ion fixed at the origin, and a closed set of equations is obtained. Solution of these equations results in a self-consistent electronic and ionic structure for the plasma as well as the average ionization, which is continuous as a function of temperature and density. Other average atom models are recovered by application of simplifying assumptions.

  6. Negative Ions in Space.

    Science.gov (United States)

    Millar, Thomas J; Walsh, Catherine; Field, Thomas A

    2017-02-08

    Until a decade ago, the only anion observed to play a prominent role in astrophysics was H - . The bound-free transitions in H - dominate the visible opacity in stars with photospheric temperatures less than 7000 K, including the Sun. The H - anion is also believed to have been critical to the formation of molecular hydrogen in the very early evolution of the Universe. Once H 2 formed, about 500 000 years after the Big Bang, the expanding gas was able to lose internal gravitational energy and collapse to form stellar objects and "protogalaxies", allowing the creation of heavier elements such as C, N, and O through nucleosynthesis. Although astronomers had considered some processes through which anions might form in interstellar clouds and circumstellar envelopes, including the important role that polycyclic aromatic hydrocarbons might play in this, it was the detection in 2006 of rotational line emission from C 6 H - that galvanized a systematic study of the abundance, distribution, and chemistry of anions in the interstellar medium. In 2007, the Cassini mission reported the unexpected detection of anions with mass-to-charge ratios of up to ∼10 000 in the upper atmosphere of Titan; this observation likewise instigated the study of fundamental chemical processes involving negative ions among planetary scientists. In this article, we review the observations of anions in interstellar clouds, circumstellar envelopes, Titan, and cometary comae. We then discuss a number of processes by which anions can be created and destroyed in these environments. The derivation of accurate rate coefficients for these processes is an essential input for the chemical kinetic modeling that is necessary to fully extract physics from the observational data. We discuss such models, along with their successes and failings, and finish with an outlook on the future.

  7. Applications of ion beam technology

    Science.gov (United States)

    Gelerinter, E.; Spielberg, N.

    1980-01-01

    Wire adhesion in steel belted radial tires; carbon fibers and composite; cold welding, brazing, and fabrication; hydrogen production, separation, and storage; membrane use; catalysis; sputtering and texture; and ion beam implantation are discussed.

  8. Ion bombardment in RF photoguns

    Energy Technology Data Exchange (ETDEWEB)

    Pozdeyev,E.; Kayran, D.; Litvinenko, V. N.

    2009-05-04

    A linac-ring eRHIC design requires a high-intensity CW source of polarized electrons. An SRF gun is viable option that can deliver the required beam. Numerical simulations presented elsewhere have shown that ion bombardment can occur in an RF gun, possibly limiting lifetime of a NEA GaAs cathode. In this paper, we analytically solve the equations of motion of ions in an RF gun using the ponderomotive potential of the Rf field. We apply the method to the BNL 1/2-cell SRF photogun and demonstrate that a significant portion of ions produced in the gun can reach the cathode if no special precautions are taken. Also, the paper discusses possible mitigation techniques that can reduce the rate of ion bombardment.

  9. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  10. Ion manipulation method and device

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Gordon A.; Baker, Erin M.; Smith, Richard D.; Ibrahim, Yehia M.

    2017-11-07

    An ion manipulation method and device is disclosed. The device includes a pair of substantially parallel surfaces. An array of inner electrodes is contained within, and extends substantially along the length of, each parallel surface. The device includes a first outer array of electrodes and a second outer array of electrodes. Each outer array of electrodes is positioned on either side of the inner electrodes, and is contained within and extends substantially along the length of each parallel surface. A DC voltage is applied to the first and second outer array of electrodes. A RF voltage, with a superimposed electric field, is applied to the inner electrodes by applying the DC voltages to each electrode. Ions either move between the parallel surfaces within an ion confinement area or along paths in the direction of the electric field, or can be trapped in the ion confinement area.

  11. Hydrated interfacial ions and electrons.

    Science.gov (United States)

    Abel, Bernd

    2013-01-01

    Charged particles such as hydrated ions and transient hydrated electrons, the simplest anionic reducing agents in water, and the special hydronium and hydroxide ions at water interfaces play an important role in many fields of science, such as atmospheric chemistry, radiation chemistry, and biology, as well as biochemistry. This article focuses on these species near hydrophobic interfaces of water, such as the air or vacuum interface of water or water protein/membrane interfaces. Ions at interfaces as well as solvated electrons have been reviewed frequently during the past decade. Although all species have been known for some time with seemingly familiar features, recently the picture in all cases became increasingly diffuse rather than clearer. The current account gives a critical state-of-the art overview of what is known and what remains to be understood and investigated about hydrated interfacial ions and electrons.

  12. Emissive Ion Thruster -EMIT Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A propulsion system is proposed that is based on acceleration of ions emitted from a thin, solid-state electrochemical ceramic membrane. This technology would...

  13. Modeling the Lithium Ion Battery

    Science.gov (United States)

    Summerfield, John

    2013-01-01

    The lithium ion battery will be a reliable electrical resource for many years to come. A simple model of the lithium ions motion due to changes in concentration and voltage is presented. The battery chosen has LiCoO[subscript 2] as the cathode, LiPF[subscript 6] as the electrolyte, and LiC[subscript 6] as the anode. The concentration gradient and…

  14. Ion association in natural brines

    Science.gov (United States)

    Truesdell, A.H.; Jones, B.F.

    1969-01-01

    Natural brines, both surface and subsurface, are highly associated aqueous solutions. Ion complexes in brines may be ion pairs in which the cation remains fully hydrated and the bond between the ions is essentially electrostatic, or coordination complexes in which one or more of the hydration water molecules are replaced by covalent bonds to the anion. Except for Cl-, the major simple ions in natural brines form ion pairs; trace and minor metals in brines form mainly coordination complexes. Limitations of the Debye-Hu??ckel relations for activity coefficients and lack of data on definition and stability of all associated species in concentrated solutions tend to produce underestimates of the degree of ion association, except where the brines contain a very high proportion of Cl-. Data and calculations on closed basin brines of highly varied composition have been coupled with electrode measurements of single-ion activities in an attempt to quantify the degree of ion association. Such data emphasize the role of magnesium complexes. Trace metal contents of closed basin brines are related to complexes formed with major anions. Alkaline sulfo- or chlorocarbonate brines (western Great Basin) carry significant trace metal contents apparently as hydroxides or hydroxy polyions. Neutral high chloride brines (Bonneville Basin) are generally deficient in trace metals. With a knowledge of the thermodynamic properties of a natural water, many possible reactions with other phases (solids, gases, other liquids) may be predicted. A knowledge of these reactions is particularly important in the study of natural brines which may be saturated with many solid phases (silicates, carbonates, sulfates, etc.), which may have a high pH and bring about dissolution of other phases (silica, amphoteric hydroxides, CO2, etc.), and which because of their high density may form relatively stable interfaces with dilute waters. ?? 1969.

  15. Principles of Magnetospheric Ion Composition.

    Science.gov (United States)

    1984-12-17

    BOREAL ) OF SIANDARDS-1963-A REPRODUtCED AT GOVERNMENT EXPENSE REPORT SD-TR-84-57 IC) Principles of Magnetospheric Ion Composition M. SCHULZ Space...species by different amounts. Entry of ionospheric ions into the plasma sheet seems to occur primarily through afternoon- and evening-sector auroral arcs...rather than through the polar wind as had previously been postulated. Energization occurs through interaction with the auroral potential structure

  16. Ion currents in diesel engines

    OpenAIRE

    Rao, Rahul

    2017-01-01

    This thesis documents an experimental and modelling investigation into ion formation in diesel engines, its uses in the field of engine performance and emissions prediction and the mechanisms by which these uses are made possible. Ion sensors have been employed in engines for a variety of purposes, including estimation of air-fuel ratio, start of combustion and in-cylinder pressure, detection of knock, misfire and combustion resonance, prediction of soot formation, and control of spark ...

  17. Heavy ion therapy: Bevalac epoch

    Energy Technology Data Exchange (ETDEWEB)

    Castro, J.R.

    1993-10-01

    An overview of heavy ion therapy at the Bevelac complex (SuperHILac linear accelerator + Bevatron) is given. Treatment planning, clinical results with helium ions on the skull base and uveal melanoma, clinical results with high-LET charged particles, neon radiotherapy of prostate cancer, heavy charged particle irradiation for unfavorable soft tissue sarcoma, preliminary results in heavy charged particle irradiation of bone sarcoma, and irradiation of bile duct carcinoma with charged particles and-or photons are all covered. (GHH)

  18. Intracellular ion channels and cancer

    OpenAIRE

    Luigi eLeanza; Lucia eBiasutto; Antonella eManago; Erich eGulbins; Mario eZoratti; Ildikò eSzabò

    2013-01-01

    Several types of channels play a role in the maintenance of ion homeostasis in subcellular organelles including endoplasmatic reticulum, nucleus, lysosome, endosome, and mitochondria. Here we give a brief overview of the contribution of various mitochondrial and other organellar channels to cancer cell proliferation or death. Much attention is focused on channels involved in intracellular calcium signaling and on ion fluxes in the ATP-producing organelle mitochondria. Mitochondrial K+ channel...

  19. Dissociative Recombination of Complex Ions

    Science.gov (United States)

    Mitchell, J. Brian A.

    1999-10-01

    The FALP-MS apparatus at the University of Rennes allows the measurement of rate coefficients for the recombination of molecular ions to be made (at 300K) even though several ions may be present in the afterglow. The recombination of a number of hydrocarbon ions derived from alkane ( Lehfaoui et al. J. Chem. Phys. 106, 5406, 1997.), alkene ( Rebrion-Rowe et al. J. Chem. Phys. 108, 7185, 1998.) and aromatic (Rebrion-Rowe et al. (Submitted to J. Chem. Phys.)) parent molecules has been studied. Despite the wide range of complexity of these compounds, the measured recombination rates are remarkably similar having values in the range of 4-10-7 cm^3.s-1. Plans are being laid for a new version of this apparatus that will allow pre-prepared ions to be injected into the inert buffer gas flow. This will allow reactive ions to be studied as well as halogen containing ions whose recombination rates would normally be masked by electron attachment to their parent gases in a conventional flowing afterglow apparatus. A high temperature modification to the CRESU supersonic flow apparatus (J.L. Le Garrec et al. J. Chem. Phys. 107, 54, 1997.) in our laboratory will allow electron attachment to radicals to be studied by means of the mass spectrometric detection of products, Langmuir probe measurement of the electron density in the flow and Laser Induced Fluorescent identification of the radical species. Such measurements are needed for the modeling of semiconductor processing plasmas.

  20. Ion Bernstein wave heating research

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Masayuki.

    1992-03-01

    Ion Bernstein wave heating (IBWH) utilizes the ion Bernstein wave (IBW), a hot plasma wave, to carry the radio frequency (rf) power to heat tokamak reactor core. Earlier wave accessibility studies have shown that this finite-Larmor-radius (FLR) mode should penetrate into a hot dense reactor plasma core without significant attenuation. Moreover, the IBW's low phase velocity ({omega}/k{sub {perpendicular}} {approx} V{sub Ti} {much lt} V{sub {alpha}}) greatly reduces the otherwise serious wave absorption by the 3.5 MeV fusion {alpha}-particles. In addition, the property of IBW's that k{sub {perpendicular}} {rho}{sub i} {approx} 1 makes localized bulk ion heating possible at the ion cyclotron harmonic layers. Such bulk ion heating can prove useful in optimizing fusion reactivity. In another vein, with proper selection of parameters, IBW's can be made subject to strong localized electron Landau damping near the major ion cyclotron harmonic resonance layers. This property can be useful, for example, for rf current drive in the reactor plasma core. This paper discusses this research.

  1. Ion Bernstein wave heating research

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Masayuki

    1992-03-01

    Ion Bernstein wave heating (IBWH) utilizes the ion Bernstein wave (IBW), a hot plasma wave, to carry the radio frequency (rf) power to heat tokamak reactor core. Earlier wave accessibility studies have shown that this finite-Larmor-radius (FLR) mode should penetrate into a hot dense reactor plasma core without significant attenuation. Moreover, the IBW`s low phase velocity ({omega}/k{sub {perpendicular}} {approx} V{sub Ti} {much_lt} V{sub {alpha}}) greatly reduces the otherwise serious wave absorption by the 3.5 MeV fusion {alpha}-particles. In addition, the property of IBW`s that k{sub {perpendicular}} {rho}{sub i} {approx} 1 makes localized bulk ion heating possible at the ion cyclotron harmonic layers. Such bulk ion heating can prove useful in optimizing fusion reactivity. In another vein, with proper selection of parameters, IBW`s can be made subject to strong localized electron Landau damping near the major ion cyclotron harmonic resonance layers. This property can be useful, for example, for rf current drive in the reactor plasma core. This paper discusses this research.

  2. Cyclotron transitions of bound ions

    Science.gov (United States)

    Bezchastnov, Victor G.; Pavlov, George G.

    2017-06-01

    A charged particle in a magnetic field possesses discrete energy levels associated with particle rotation around the field lines. The radiative transitions between these levels are the well-known cyclotron transitions. We show that a bound complex of particles with a nonzero net charge displays analogous transitions between the states of confined motion of the entire complex in the field. The latter bound-ion cyclotron transitions are affected by a coupling between the collective and internal motions of the complex and, as a result, differ from the transitions of a "reference" bare ion with the same mass and charge. We analyze the cyclotron transitions for complex ions by including the coupling within a rigorous quantum approach. Particular attention is paid to comparison of the transition energies and oscillator strengths to those of the bare ion. Selection rules based on integrals of collective motion are derived for the bound-ion cyclotron transitions analytically, and the perturbation and coupled-channel approaches are developed to study the transitions quantitatively. Representative examples are considered and discussed for positive and negative atomic and cluster ions.

  3. Low Z impurity ion extraction from TFTR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Kamperschroer, J.H.; Grisham, L.R.; Newman, R.A.; O' Connor, T.E.; Stevenson, T.N.; von Halle, A.; Williams, M.D.; Wright, K.E.

    1993-04-01

    TFTR deuterium neutral beams have been operated unintentionally with significant quantities of extracted water ions. Water has been observed with an Optical Multichannel Analyzer (OMA) during beam extraction when small water leaks were present within the arc chamber. These leaks were thermally induced with the contamination level increasing linearly with pulse length. 6% of the beam current was attributed to water ions for the worst leak, corresponding to an instantaneous value of 12% at the end of a 1.5 s pulse. A pre-calorimeter collimator was damaged as a result of this operation. A similar contamination is observed during initial operation of ion sources exposed to air. This latter contamination is attributed to the synthesis, from adsorbed air, of either D[sub 2]O or the indistinguishable ND[sub 3]. Initial operation of new ion sources typically produces a contamination level of [approximately]2%. These impurities are reduced to undetectable levels after 50 to 100 beam pulses. Once a water molecule is present in the plasma generator, it is predominantly ionized rather than dissociated, resulting in the extraction of only trace amounts of hydrogenated ions. The addition of water to the extracted beam also reduces the optimum perveance, moving the typical underdense operating point closer to optimum, causing the frequency of grid faults to increase. Close to 90% of the water extracted from ion sources with water leaks was deuterated, implying that the potential exists for the production of tritiated water during TFTR's forthcoming DT operation. Isotope exchange in the plasma generator takes place rapidly and is believed to be surface catalyzed. The primary concern is with O implanted into beam absorbers recombining with tritium, and the subsequent hold up of T[sub 2]O on cryopanels. Continuous surveillance with the OMA diagnostic during DT operation will ensure that ion sources with detectable water are not operated with tritium.

  4. Low Z impurity ion extraction from TFTR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Kamperschroer, J.H.; Grisham, L.R.; Newman, R.A.; O`Connor, T.E.; Stevenson, T.N.; von Halle, A.; Williams, M.D.; Wright, K.E.

    1993-04-01

    TFTR deuterium neutral beams have been operated unintentionally with significant quantities of extracted water ions. Water has been observed with an Optical Multichannel Analyzer (OMA) during beam extraction when small water leaks were present within the arc chamber. These leaks were thermally induced with the contamination level increasing linearly with pulse length. 6% of the beam current was attributed to water ions for the worst leak, corresponding to an instantaneous value of 12% at the end of a 1.5 s pulse. A pre-calorimeter collimator was damaged as a result of this operation. A similar contamination is observed during initial operation of ion sources exposed to air. This latter contamination is attributed to the synthesis, from adsorbed air, of either D{sub 2}O or the indistinguishable ND{sub 3}. Initial operation of new ion sources typically produces a contamination level of {approximately}2%. These impurities are reduced to undetectable levels after 50 to 100 beam pulses. Once a water molecule is present in the plasma generator, it is predominantly ionized rather than dissociated, resulting in the extraction of only trace amounts of hydrogenated ions. The addition of water to the extracted beam also reduces the optimum perveance, moving the typical underdense operating point closer to optimum, causing the frequency of grid faults to increase. Close to 90% of the water extracted from ion sources with water leaks was deuterated, implying that the potential exists for the production of tritiated water during TFTR`s forthcoming DT operation. Isotope exchange in the plasma generator takes place rapidly and is believed to be surface catalyzed. The primary concern is with O implanted into beam absorbers recombining with tritium, and the subsequent hold up of T{sub 2}O on cryopanels. Continuous surveillance with the OMA diagnostic during DT operation will ensure that ion sources with detectable water are not operated with tritium.

  5. On a cryogenic noble gas ion catcher

    NARCIS (Netherlands)

    Dendooven, P; Purushothaman, S; Gloos, K

    2006-01-01

    In situ purification of the gas used as stopping medium in a noble gas ion catcher by operating the device at low temperatures of 60-150 K was investigated. Alpha-decay recoil ions from a Ra-223 source served as energetic probes. The combined ion survival and transport efficiencies for Rn-219 ions

  6. A sensitive fluorescent sensor of lanthanide ions

    CERN Document Server

    Bekiari, V; Lianos, P

    2003-01-01

    A fluorescent probe bearing a diazostilbene chromophore and a benzo-15-crown-5 ether moiety is a very efficient sensor of lanthanide ions. The ligand emits strong fluorescence only in the presence of specific ions, namely lanthanide ions, while the emission wavelength is associated with a particular ion providing high sensitivity and resolution.

  7. Scanning reflection ion microscopy in a helium ion microscope

    Directory of Open Access Journals (Sweden)

    Yuri V. Petrov

    2015-05-01

    Full Text Available Reflection ion microscopy (RIM is a technique that uses a low angle of incidence and scattered ions to form an image of the specimen surface. This paper reports on the development of the instrumentation and the analysis of the capabilities and limitations of the scanning RIM in a helium ion microscope (HIM. The reflected ions were detected by their “conversion” to secondary electrons on a platinum surface. An angle of incidence in the range 5–10° was used in the experimental setup. It was shown that the RIM image contrast was determined mostly by surface morphology but not by the atomic composition. A simple geometrical analysis of the reflection process was performed together with a Monte Carlo simulation of the angular dependence of the reflected ion yield. An interpretation of the RIM image formation and a quantification of the height of the surface steps were performed. The minimum detectable step height was found to be approximately 5 nm. RIM imaging of an insulator surface without the need for charge compensation was successfully demonstrated.

  8. Observations of strong ion-ion correlations in dense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T.; Fletcher, L.; Pak, A.; Chapman, D. A.; Falcone, R. W.; Fortmann, C.; Galtier, E.; Gericke, D. O.; Gregori, G.; Hastings, J.; Landen, O. L.; Le Pape, S.; Lee, H. J.; Nagler, B.; Neumayer, P.; Turnbull, D.; Vorberger, J.; White, T. G.; Wünsch, K.; Zastrau, U.; Glenzer, S. H.; Döppner, T.

    2014-05-01

    Using simultaneous spectrally, angularly, and temporally resolved x-ray scattering, we measure the pronounced ion-ion correlation peak in a strongly coupled plasma. Laser-driven shock-compressed aluminum at ~3× solid density is probed with high-energy photons at 17.9 keV created by molybdenum He-α emission in a laser-driven plasma source. The measured elastic scattering feature shows a well-pronounced correlation peak at a wave vector of k=4k=4Å-1. The magnitude of this correlation peak cannot be described by standard plasma theories employing a linear screened Coulomb potential. Advanced models, including a strong short-range repulsion due to the inner structure of the aluminum ions are however in good agreement with the scattering data. These studies have demonstrated a new highly accurate diagnostic technique to directly measure the state of compression and the ion-ion correlations. We have since applied this new method in single-shot wave-number resolved S(k) measurements to characterize the physical properties of dense plasmas.

  9. Ion beam analysis fundamentals and applications

    CERN Document Server

    Nastasi, Michael; Wang, Yongqiang

    2015-01-01

    Ion Beam Analysis: Fundamentals and Applications explains the basic characteristics of ion beams as applied to the analysis of materials, as well as ion beam analysis (IBA) of art/archaeological objects. It focuses on the fundamentals and applications of ion beam methods of materials characterization.The book explains how ions interact with solids and describes what information can be gained. It starts by covering the fundamentals of ion beam analysis, including kinematics, ion stopping, Rutherford backscattering, channeling, elastic recoil detection, particle induced x-ray emission, and nucle

  10. Modification of graphene by ion beam

    Science.gov (United States)

    Gawlik, G.; Ciepielewski, P.; Jagielski, J.; Baranowski, J.

    2017-09-01

    Ion induced defect generation in graphene was analyzed using Raman spectroscopy. A single layer graphene membrane produced by chemical vapor deposition (CVD) on copper foil and then transferred on glass substrate was subjected to helium, carbon, nitrogen, argon and krypton ions bombardment at energies from the range 25 keV to 100 keV. A density of ion induced defects and theirs mean size were estimated by using Raman measurements. Increasing number of defects generated by ion with increase of ion mass and decrease of ion energy was observed. Dependence of ion defect efficiency (defects/ion) on ion mass end energy was proportional to nuclear stopping power simulated by SRIM. No correlation between ion defect efficiency and electronic stopping power was observed.

  11. Cyclotron axial ion-beam-buncher system

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, R.W.; Swenson, D.A.; Wangler, T.P.

    1982-02-11

    Adiabatic ion bunching is achieved in a cyclotron axial ion injection system through the incorporation of a radio frequency quadrupole system, which receives ions from an external ion source via an accelerate-decelerate system and a focusing einzel lens system, and which adiabatically bunches and then injects the ions into the median plane of a cyclotron via an electrostatic quadrupole system and an inflection mirror.

  12. The ion pairs and superconducting bosons

    OpenAIRE

    Minasyan, V. N.

    2008-01-01

    First, it is shown that the creation of the spinless ion pairs in the lattice, which are hold by the binding with neighbor ion pairs together regarded as covalent. These ion pairs are created by the repulsive potential interaction of two ions which is bound as linear oscillator. The repulsive S-wave scattering between ion pairs and electrons is transformed to the attractive effective interaction between electrons which leads to a creation of electron pairs by a binding energy depending on the...

  13. Maskless, resistless ion beam lithography

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Qing [Univ. of California, Berkeley, CA (United States)

    2003-01-01

    As the dimensions of semiconductor devices are scaled down, in order to achieve higher levels of integration, optical lithography will no longer be sufficient for the needs of the semiconductor industry. Alternative next-generation lithography (NGL) approaches, such as extreme ultra-violet (EUV), X-ray, electron-beam, and ion projection lithography face some challenging issues with complicated mask technology and low throughput. Among the four major alternative NGL approaches, ion beam lithography is the only one that can provide both maskless and resistless patterning. As such, it can potentially make nano-fabrication much simpler. This thesis investigates a focused ion beam system for maskless, resistless patterning that can be made practical for high-volume production. In order to achieve maskless, resistless patterning, the ion source must be able to produce a variety of ion species. The compact FIB system being developed uses a multicusp plasma ion source, which can generate ion beams of various elements, such as O2+, BF2+, P+ etc., for surface modification and doping applications. With optimized source condition, around 85% of BF2+, over 90% of O2+ and P+ have been achieved. The brightness of the multicusp-plasma ion source is a key issue for its application to maskless ion beam lithography. It can be substantially improved by optimizing the source configuration and extractor geometry. Measured brightness of 2 keV He+ beam is as high as 440 A/cm2 • Sr, which represents a 30x improvement over prior work. Direct patterning of Si thin film using a focused O2+ ion beam has been investigated. A thin surface oxide film can be selectively formed using 3 keV O2+ ions with the dose of 1015 cm-2. The oxide can then serve as a hard mask for patterning of the Si film. The

  14. Marine Toxins Targeting Ion Channels

    Directory of Open Access Journals (Sweden)

    Hugo R. Arias

    2006-04-01

    Full Text Available Abstract: This introductory minireview points out the importance of ion channels for cell communication. The basic concepts on the structure and function of ion channels triggered by membrane voltage changes, the so-called voltage-gated ion channels (VGICs, as well as those activated by neurotransmitters, the so-called ligand-gated ion channel (LGICs, are introduced. Among the most important VGIC superfamiles, we can name the voltage-gated Na+ (NaV, Ca2+ (CaV, and K+ (KV channels. Among the most important LGIC super families, we can include the Cys-loop or nicotinicoid, the glutamate-activated (GluR, and the ATP-activated (P2XnR receptor superfamilies. Ion channels are transmembrane proteins that allow the passage of different ions in a specific or unspecific manner. For instance, the activation of NaV, CaV, or KV channels opens a pore that is specific for Na+, Ca2+, or K+, respectively. On the other hand, the activation of certain LGICs such as nicotinic acetylcholine receptors, GluRs, and P2XnRs allows the passage of cations (e.g., Na+, K+, and/or Ca2+, whereas the activation of other LGICs such as type A γ-butyric acid and glycine receptors allows the passage of anions (e.g., Cl− and/or HCO3−. In this regard, the activation of NaV and CaV as well as ligand-gated cation channels produce membrane depolarization, which finally leads to stimulatory effects in the cell, whereas the activation of KV as well as ligand-gated anion channels induce membrane hyperpolarization that finally leads to inhibitory effects in the cell. The importance of these ion channel superfamilies is emphasized by considering their physiological functions throughout the body as well as their pathophysiological implicance in several neuronal diseases. In this regard, natural molecules, and especially marine toxins, can be potentially used as modulators (e.g., inhibitors or prolongers of ion channel functions to treat or to alleviate a specific

  15. THOR Ion Mass Spectrometer (IMS)

    Science.gov (United States)

    Retinò, Alessandro

    2017-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The Ion Mass Spectrometer (IMS) onboard THOR will provide the first high-time resolution measurements of mass-resolved ions in near-Earth space, focusing on hot ions in the foreshock, shock and magnetosheath turbulent regions. These measurements are required to study how kinetic-scale turbulent fluctuations heat and accelerate different ion species. IMS will measure the full three-dimensional distribution functions of main ion species (H+, He++, O+) in the energy range 10 eV/q to 30 keV/q with energy resolution DE/E down to 10% and angular resolution down to 11.25˚ . The time resolution will be 150 ms for O+, 300 ms for He++ and ˜ 1s for O+, which correspond to ion scales in the the foreshock, shock and magnetosheath regions. Such high time resolution is achieved by mounting four identical IMS units phased by 90˚ in the spacecraft spin plane. Each IMS unit combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. Adequate mass-per-charge resolution (M/q)/(ΔM/q) (≥ 8 for He++ and ≥ 3 for O+) is obtained through a 6 cm long Time-of-Flight (TOF) section. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCPs) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification and discrimination and a discrete Time-to-Amplitude Converter (TAC) to determine the ion time of flight. A processor board will be used to for ion events formatting and will interface with the Particle Processing Unit (PPU), which will perform data processing for THOR particle detectors. The IMS instrument is being designed and will be built and calibrated by an international consortium of scientific institutes from France, USA, Germany and Japan and Switzerland.

  16. Ionomers for Ion-Conducting Energy Materials

    Science.gov (United States)

    Colby, Ralph

    For ionic actuators and battery separators, it is vital to utilize single-ion conducting ionomers that avoid the detrimental polarization of other ions. Single-ion conducting ionomers are synthesized based on DFT calculations, with low glass transition temperatures (facile dynamics) to prepare ion-conducting membranes for battery separators that conduct Li+ or Na+. Characterization by X-ray scattering, dielectric spectroscopy, FTIR, NMR and linear viscoelasticity collectively develop a coherent picture of ionic aggregation and both counterion and polymer dynamics. 7Li NMR diffusion measurements find that diffusion is faster than expected by conductivity using the Nernst-Einstein equation, which means that the majority of Li diffusion occurs by ion pairs moving with the polymer segmental motion. Segmental motion only contributes to ionic conduction in the rare event that one of these ion pairs has an extra Li (a positive triple ion). This leads us to a new metric for ion-conducting soft materials, the product of the cation number density p0 and their diffusion coefficient D; p0D is the diffusive flux of lithium ions. This new metric has a maximum at intermediate ion content that corresponds to the overlap of ion pair polarizability volumes. At higher ion contents, the ion pairs interact strongly and form larger aggregation states that retard segmental motion of both mobile ion pairs and triple ions.

  17. Numerical Simulation of Ion Rings and Ion Beam Propagation.

    Science.gov (United States)

    Mankofsky, Alan

    This thesis presents the development of numerical simulation techniques for studying the physics of ion beams and rings in a background plasma as applicable to certain problems in magnetic and inertial confinement fusion. Two codes have been developed for these purposes: RINGA and CIDER. The 2 and 1/2-dimensional (r,z,v(,r),v(,(theta)),v(,z); (PAR-DIFF)/(PAR-DIFF)(theta) = 0) particle code RINGA follows the trajectories of ions in their self-consistent magnetic field. The code assumes strict charge neutrality and admits currents only in the azimuthal direction, i.e., (PHI) = J(,r) = J(,z) = 0. The injection and resistive trapping of ion rings has been studied with RINGA. The number of particles trapped as a fraction of the total number injected N is found to be strongly dependent upon (1) N (in the range 2.85 x 10('16) - 3.99 x 10('17)) and (2) mirror ratios in the system (1.05 -1.14), and more weakly dependent upon (3) wall resistance per unit length (0.72 (OMEGA)/cm - 1.80 (OMEGA)/cm) and (4) beam divergence (0(DEGREES)-6(DEGREES)). Fractions of trapped particles in excess of 0.9 have been observed. Modifications to RINGA to include finite pressure of confined plasma and beam ion-electron slowing down collisions are discussed. Finite plasma pressure leads to a diamagnetic current which increases the field reversal factor in ion ring equilibria, while causing the closed flux surfaces to expand outward. The ideal magnetohydrodynamic stability of the plasma is analyzed in the high toroidal mode number limit, where the beam ions are noninteracting. The existence of stable high-(beta) equilibria is demonstrated. One such equilibrium, stable to both ideal interchange and ballooning modes, has (TBOND) 8(pi) / (DBLTURN) 55%. In the CIDER hybrid code, ions are represented by particles and electrons by an inertialess thermal fluid which obeys a generalized Ohm's law. Fields are solved in the quasineutral Darwin approximation. Several collisional and atomic processes are

  18. Characterization of ISOLDE ion source and ion source chemistry

    CERN Document Server

    Barbeau, Marion

    2014-01-01

    This report presents results of measurements made with the ISOLDE OFF-LINE mass separator [1]. The first part shows measurements of the ionization characteristics of noble gases in a VADIS ion source. The goal of the measurements was to determine the dependency of the extractable current of first and second noble gases ions with the electron energy. In the second part, investigation on in-target chemistry are presented. Here, the effect of injected sulfur hexafluoride ($SF_6$) on the release of oxygen from aluminium oxide ($Al_2 O_3$) was studied.

  19. Industrial ion sources broadbeam gridless ion source technology

    CERN Document Server

    Zhurin, Viacheslav V

    2012-01-01

    Due to the large number of uses of ion sources in academia and industry, those who utilize these sources need up to date and coherent information to keep themselves abreast of developments and options, and to chose ideal solutions for quality and cost-effectiveness. This book, written by an author with a strong industrial background and excellent standing, is the comprehensive guide users and developers of ion sources have been waiting for. Providing a thorough refresher on the physics involved, this resource systematically covers the source types, components, and the operational parameters.

  20. Heavy ion fusion--Using heavy ions to make electricity

    Energy Technology Data Exchange (ETDEWEB)

    Celata, C.M.

    2004-03-15

    The idea of using nuclear fusion as a source of commercial electrical power has been pursued worldwide since the 1950s. Two approaches, using magnetic and inertial confinement of the reactants, are under study. This paper describes the difference between the two approaches, and discusses in more detail the heavy-ion-driven inertial fusion concept. A multibeam induction linear accelerator would be used to bring {approx}100 heavy ion beams to a few GeV. The beams would then heat and compress a target of solid D-T. This approach is unique among fusion concepts in its ability to protect the reaction chamber wall from neutrons and debris.

  1. Cholesterol binding to ion channels

    Directory of Open Access Journals (Sweden)

    Irena eLevitan

    2014-02-01

    Full Text Available Numerous studies demonstrated that membrane cholesterol is a major regulator of ion channel function. The goal of this review is to discuss significant advances that have been recently achieved in elucidating the mechanisms responsible for cholesterol regulation of ion channels. The first major insight that comes from growing number of studies that based on the sterol specificity of cholesterol effects, show that several types of ion channels (nAChR, Kir, BK, TRPV are regulated by specific sterol-protein interactions. This conclusion is supported by demonstrating direct saturable binding of cholesterol to a bacterial Kir channel. The second major advance in the field is the identification of putative cholesterol binding sites in several types of ion channels. These include sites at locations associated with the well-known cholesterol binding motif CRAC and its reversed form CARC in nAChR, BK, and TRPV, as well as novel cholesterol binding regions in Kir channels. Notably, in the majority of these channels, cholesterol is suggested to interact mainly with hydrophobic residues in non-annular regions of the channels being embedded in between transmembrane protein helices. We also discuss how identification of putative cholesterol binding sites is an essential step to understand the mechanistic basis of cholesterol-induced channel regulation. Clearly, however, these are only the first few steps in obtaining a general understanding of cholesterol-ion channels interactions and their roles in cellular and organ functions.

  2. Heavy-ion nucleus scattering

    CERN Document Server

    Rahman, M A; Haque, S

    2003-01-01

    Heavy ion-nucleus scattering is an excellent laboratory to probe high spin phenomena, exotic nuclei and for the analysis of various exit channels. The Strong Absorption Model or the generalized diffraction models, which are semi-classical in nature, have been employed in the description of various heavy ion-nucleus scattering phenomena with reasonable success. But one needs to treat the deflection function (scattering angles) quantum mechanically in the Wave Mechanical picture for the appropriate description of the heavy-ion nucleus scattering phenomena. We have brought the mathematics for the cross-section of the heavy-ion nucleus scattering to an analytic expression taking account of the deflection function (scattering angles) quantum mechanically. sup 9 Be, sup 1 sup 6 O, sup 2 sup 0 Ne and sup 3 sup 2 S heavy-ion beams elastic scattering from sup 2 sup 8 Si, sup 2 sup 4 Mg and sup 4 sup 0 Ca target nuclei at various projectile energies over the range 20-151 MeV have been analysed in terms of the 2-paramet...

  3. Rotation sensing with trapped ions

    Science.gov (United States)

    Campbell, W. C.; Hamilton, P.

    2017-03-01

    We present a protocol for rotation measurement via matter-wave Sagnac interferometry using trapped ions. The ion trap based interferometer encloses a large area in a compact apparatus through repeated round-trips in a Sagnac geometry. We show how a uniform magnetic field can be used to close the interferometer over a large dynamic range in rotation speed and measurement bandwidth without contrast loss. Since this technique does not require the ions to be confined in the Lamb-Dicke regime, Doppler laser cooling should be sufficient to reach a sensitivity of { S }=1.4× {10}-6 {{rad}} {{{s}}}-1 {{{H}}{{z}}}-1/2. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Wes Campbell was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  4. Results of heavy ion radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Castro, J.R. [Lawrence Berkeley Lab., CA (United States). Life Sciences Div.

    1994-04-01

    The potential of heavy ion therapy for clinical use in cancer therapy stems from the biological parameters of heavy charged particles, and their precise dose localization. Biologically, carbon, neon and other heavy ion beams (up to about silicon) are clinically useful in overcoming the radioresistance of hypoxic tumors, thus increasing biological effectiveness relative to low-LET x-ray or electron beams. Cells irradiated by heavy ions show less variation in cell-cycle related radiosensitivity and decreased repair of radiation injury. The physical parameters of these heavy charged particles allow precise delivery of high radiation doses to tumors while minimizing irradiation of normal tissues. Clinical use requires close interaction between radiation oncologists, medical physicists, accelerator physicists, engineers, computer scientists and radiation biologists.

  5. Miniature Bipolar Electrostatic Ion Thruster

    Science.gov (United States)

    Hartley, Frank T.

    2006-01-01

    The figure presents a concept of a bipolar miniature electrostatic ion thruster for maneuvering a small spacecraft. The ionization device in the proposed thruster would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several mega-volts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. In a thruster-based on this concept, one or more propellant gases would be introduced into such a membrane ionizer. Unlike in larger prior ion thrusters, all of the propellant molecules would be ionized. This thruster would be capable of bipolar operation. There would be two accelerator grids - one located forward and one located aft of the membrane ionizer. In one mode of operation, which one could denote the forward mode, positive ions leaving the ionizer on the backside would be accelerated to high momentum by an electric field between the ionizer and an accelerator grid. Electrons leaving the ionizer on the front side would be ejected into free space by a smaller accelerating field. The equality of the ion and electron currents would eliminate the need for an additional electron- or ion-emitting device to keep the spacecraft charge-neutral. In another mode of operation, which could denote the reverse mode, the polarities of the voltages applied to the accelerator grids and to the electrodes of the membrane ionizer would be the reverse of those of the forward mode. The reversal of electric fields would cause the ion and electrons to be ejected in the reverse of their forward mode directions, thereby giving rise to thrust in the direction opposite that of the forward mode.

  6. Ion Implantation and Synthesis of Materials

    CERN Document Server

    Nastasi, Michael

    2006-01-01

    Ion implantation is one of the key processing steps in silicon integrated circuit technology. Some integrated circuits require up to 17 implantation steps and circuits are seldom processed with less than 10 implantation steps. Controlled doping at controlled depths is an essential feature of implantation. Ion beam processing can also be used to improve corrosion resistance, to harden surfaces, to reduce wear and, in general, to improve materials properties. This book presents the physics and materials science of ion implantation and ion beam modification of materials. It covers ion-solid interactions used to predict ion ranges, ion straggling and lattice disorder. Also treated are shallow-junction formation and slicing silicon with hydrogen ion beams. Topics important for materials modification, such as ion-beam mixing, stresses, and sputtering, are also described.

  7. Fast ion-atom and ion-molecule collisions

    CERN Document Server

    2013-01-01

    The principal goal of this book is to provide state-of-the art coverage of the non-relativistic three- and four-body theories at intermediate and high energy ion-atom and ion-molecule collisions. The focus is on the most frequently studied processes: electron capture, ionization, transfer excitation and transfer ionization. The content is suitable both for graduate students and experienced researchers. For these collisions, the literature has seen enormous renewal of activity in the development and applications of quantum-mechanical theories. This subject is of relevance in several branches of science and technology, like accelerator-based physics, the search for new sources of energy and high temperature fusion of light ions. Other important applications are in life sciences via medicine, where high-energy ion beams are used in radiotherapy for which a number of storage ring accelerators are in full operation, under construction or planned to be built worldwide. Therefore, it is necessary to review this fiel...

  8. Ion-Beam-Excited, Electrostatic, Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  9. Ion-Beam-Excited Electrostatic Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  10. Low Energy Ion Implanting of Silver Ion in Titanium

    Directory of Open Access Journals (Sweden)

    Fernanda Elisa Demore Palandi

    2014-08-01

    Full Text Available In modern medicine, biomaterials have been widely used as implants. Among biomaterials, titanium medical class is distinguished by its high degree of biocompatibility. However, orthoses and prostheses infected with post-implanted microorganisms require surgeries and medical interventions that are costly and treatment can take months. To combat infections associated with implants, the best strategy is to prevent them from occurring. One strategy is the silver ion implantation in titanium. In this work, silver ions were implanted at low energies (4 keV in medical titanium with the goal to take bactericide titanium surface and therefore, inhibit biofilm formation. The implantation was done using the Ion Plating equipment. After ion implantation, the samples were analyzing for Rutherford Backscattering Spectrometry, Glow-Discharge Optical Emission Spectroscopy and X-Ray Diffraction. The results show that the silver was implanted at depths up to 10 nm, corroborating simulation data. In addition, the strategy used in this work can be applied on an industrial scale due to the type of equipment used for the surface treatment.

  11. Heavy ions: Report from Relativistic Heavy Ion Collider

    Indian Academy of Sciences (India)

    We review selected highlights from the experiments at the Relativistic Heavy Ion Collider (RHIC) exploring the QCD phase diagram. A wealth of new results appeared recently from RHIC due to major recent upgrades, like for example the Υ suppression in central nucleus-nucleus collisions which has been discovered ...

  12. Ion composition variety and variability around perihelion

    Science.gov (United States)

    Beth, Arnaud; Altwegg, Kathrin; Behar, Étienne; Broiles, Tom; Burch, Jim; Carr, Christopher; Eriksson, Anders; Galand, Marina; Goetz, Charlotte; Henri, Pierre; Heritier, Kévin; Nilsson, Hans; Odelstad, Elias; Richter, Ingo; Rubin, Martin; Vallieres, Xavier

    2017-04-01

    For two years, the Double Focusing Mass Spectrometer (DFMS), one of the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) onboard Rosetta probed the neutral gas and the plasma composition of the comet 67P/Churyumov-Gerasimenko's coma (67P). Major ion species detected include water ions (e.g, H2O+, H3O+, HO+) observed throughout the escorting phase. The analysis of DFMS data revealed a large zoo of ion species near perihelion (summer 2015). In particular, protonated versions of high proton affinity neutrals (e.g., NH4+) were detected, but also hydrocarbon and organic ion species. Near perihelion, ion composition was also highly variable and showed interesting variations in the complexity of the observed ion species. We will first present an overview of the rich variety of ion species observed during perihelion. This study will be supported by ionospheric modeling of ion composition below the ion exobase. We will then show an intercomparison between DFMS data and Rosetta Plasma Consortium (RPC) plasma and particle data to interpret the DFMS ion composition variability. Our primary goal is to highlight any correlation between observations from these different instruments (i.e. ion composition, ion and electron number density, energy distribution, magnetic field) and to find relevant signatures of physical processes which can affect the chemistry and dynamics (e.g., acceleration and deflection) of the involved neutral and ion species.

  13. Therapeutic approaches to ion channel diseases.

    Science.gov (United States)

    Camerino, Diana Conte; Desaphy, Jean-François; Tricarico, Domenico; Pierno, Sabata; Liantonio, Antonella

    2008-01-01

    More than 400 genes are known that encode ion channel subunits. In addition, alternative splicing and heteromeric assembly of different subunits increase tremendously the variety of ion channels. Such many channels are needed to accomplish very complex cellular functions, whereas dysfunction of ion channels are key events in many pathological processes. The recent discovery of ion channelopathies, which, in its more stringent definition, encloses monogenic disorders due to mutations in ion channel genes, has largely contributed to our understanding of the function of the various channel subtypes and of the role of ion channels in multigenic or acquired diseases. Last but not least, ion channels are the main targets of many drugs already used in the clinics. Most of these drugs were introduced in therapy based on the experience acquired quite empirically, and many were discovered afterward to target ion channels. Now, intense research is being conducted to develop new drugs acting selectively on ion channel subtypes and aimed at the understanding of the intimate drug-channel interaction. In this review, we first focus on the pharmacotherapy of ion channel diseases, which includes many drugs targeting ion channels. Then, we describe the molecular pharmacology of ion channels, including the more recent advancement in drug development. Among the newest aspect of ion channel pharmacology, we draw attention to how polymorphisms or mutations in ion channel genes may modify sensitivity to drugs, opening the way toward the development of pharmacogenetics.

  14. Ion Heating in the Martian Ionosphere

    Science.gov (United States)

    Fowler, C. M.; Ergun, R. E.; Andersson, L.; Peterson, W. K.; Hara, T.; Mcfadden, J.; Espley, J.; Halekas, J.; Mitchell, D. L.; Mazelle, C.; Jakosky, B. M.

    2017-10-01

    Energetic O+ and O2+ ions with energies of up to a few hundred eV are observed in the Martian ionosphere. Corresponding ion velocity distributions show ion conics, suggesting that the observed ion populations have been heated perpendicular to the local magnetic field before experiencing a magnetic mirror force. Magnetic field observations support these interpretations: wave power at the local O+ and O2+ gyrofrequencies in the spacecraft frame is observed coincident with the energetic ions, within an apparent magnetic field bottle-like topology. Analysis of the observed ion conics leads to estimates of ion temperatures of 10-30 eV. We suggest that the ion populations are initially heated perpendicular to the local magnetic field by wave power propagating inward from the Mars-solar wind interaction. The local magnetic field "balloons out" in response to these enhanced ion temperatures and pressures. The resultant magnetic field topology is bottle like; the transversely heated ions would subsequently experience a magnetic mirror force in the converging field regions, agreeing with the reported observations. Such strong heating events that significantly increase the ion temperature and pressure, thereby decreasing the net magnetic field, are rare and seem to occur under specific interplanetary magnetic field orientations. Events were observed to span the upper exobase region and just above, a region characterized by significant ion densities in an increasingly collisionless domain. Ion heating in this region has the potential to drive significant ion outflows, thus contributing to atmospheric loss from the planet.

  15. Understanding Molecular Ion-Neutral Atom Collisions for the Production of Ultracold Molecular Ions

    Science.gov (United States)

    2016-06-06

    Understanding Molecular Ion-Neutral Atom Collisions for the Production of Utracold Molecular Ions In the last five years, the study of ultracold...U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 molecular ion, quantum chemistry, atom ion interaction...Molecular Ion-Neutral Atom Collisions for the Production of Utracold Molecular Ions Report Title In the last five years, the study of ultracold molecular

  16. Clotrimazole-triiodide ion association as an ion exchanger for a triiodide ion-selective electrode.

    Science.gov (United States)

    Farhadi, Khalil; Maleki, Ramin

    2002-02-01

    A novel triiodide ion-selective electrode based on a clotrimazole-triiodide ion pair as a membrane carrier was prepared. It has a linear response to triiodide from 8 x 10(-6) to 5 x 10(-3) M with a slope of -68.9 mV per decade and a detection limit of 5 x 10(-6) M. The electrode response is independent of the pH of the solution in the pH range 2-9. It has a very short response time and can be used for at least 3 months without any considerable divergence in the potentials. The proposed sensor revealed very good selectivities for I3- over a variety of other anions. It was used as an indicator electrode in the potentiometric titration of triiodide ions and in an indirect potentiometric determination of clotrimazole in pharmaceutical preparations.

  17. A fast beam-ion instability

    Energy Technology Data Exchange (ETDEWEB)

    Stupakov, G.V. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    The ionization of residual gas by an electron beam in an accelerator generates ions that can resonantly couple to the beam through a wave propagating in the beam-ion system. Results of the study of a beam-ion instability are presented for a multi-bunch train taking into account the decoherence of ion oscillations due to the ion frequency spread and spatial variation of the ion frequency. It is shown that the combination of both effects can substantially reduce the growth rate of the instability. (author)

  18. Ion mobility spectrometer with virtual aperture grid

    Science.gov (United States)

    Pfeifer, Kent B.; Rumpf, Arthur N.

    2010-11-23

    An ion mobility spectrometer does not require a physical aperture grid to prevent premature ion detector response. The last electrodes adjacent to the ion collector (typically the last four or five) have an electrode pitch that is less than the width of the ion swarm and each of the adjacent electrodes is connected to a source of free charge, thereby providing a virtual aperture grid at the end of the drift region that shields the ion collector from the mirror current of the approaching ion swarm. The virtual aperture grid is less complex in assembly and function and is less sensitive to vibrations than the physical aperture grid.

  19. ADVANCED TECHNOLOGY WASTEWATER TREATMENT OF NITRITE IONS

    Directory of Open Access Journals (Sweden)

    E.G. Morozov

    2012-06-01

    Full Text Available The main reason for high concentration of nitrite ions in water is the existence of sources of industrial and agricultural pollution. Contamination of drinking water, juices, wine and other liquids of nitrite ions as a result of improper use of nitrogen fertilizers has an adverse effect on living organism, because under the influence of enzymes nitrite ions in living organisms form high carcinogenic nitrosamines, and the interaction of nitrite ions from blood hemoglobin causes such toxicity that leads to disease cyanosis [1]. Therefore removal of nitrite ions from water has received increased attention. The paper discusses an innovative wastewater treatment technology from the nitrite ion with hypochlorite produced during electrolysis.

  20. Infrared spectroscopy of weakly bound molecular ions

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Lisa I-Ching

    1988-11-01

    The infrared spectra of a series of hydrated hydronium cluster ions and of protonated ethane ion are presented. A tandem mass spectrometer is ideally suited to obtaining the spectra of such weakly bound molecular ions. Traditional absorption spectroscopy is not feasible in these situations, so the techniques described in this thesis make use of some consequence of photon absorption with higher sensitivity than simply attenuation of laser power. That consequence is dissociation. By first mass selecting the parent ion under study and then mass selecting the fragment ion formed from dissociation, the near unit detection efficiency of ion counting methods has been used to full advantage.

  1. Microfluidic ion-sensing devices.

    Science.gov (United States)

    Johnson, R Daniel; Gavalas, Vasilis G; Daunert, Sylvia; Bachas, Leonidas G

    2008-04-14

    Quantitative determinations of ions in a variety of media have been performed traditionally via one of three approaches: optical instrumental methods (e.g., atomic absorption, and inductively-coupled plasma-optical emission or mass spectrometry), "wet" methods, or ion-selective sensors. Each of the approaches, though, possesses limitations including: power/reagent consumption and lack of portability for instrumental techniques; laborious sample-treatment steps for wet methods; and lack of selectivity and sensitivity with sensors when employed with complex samples. Microfluidic device have emerged as a solution to some of these challenges associated with ion analysis. Such systems can integrate multiple sample handling, calibration, and detection steps ("lab-on-a-chip" concept) into a footprint amenable to portability, while requiring small amounts of sample and power. Furthermore, devices can be constructed for multi-analyte detection, either through multiple parallel fluidic architectures or by using arrays of detection elements. This paper reviews recent progress in the development of total-analysis systems for ionic species. Fabrication techniques and various fluid-handling operations are discussed briefly, followed by a number of more mature strategies for microfluidic ion analysis. A variety of approaches expected to comprise the next generation of devices are also presented.

  2. Microfluidic ion-sensing devices

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R. Daniel [Department of Chemistry, Murray State University, Murray, KY 42071-3346 (United States)], E-mail: daniel.johnson@murraystate.edu; Gavalas, Vasilis G.; Daunert, Sylvia [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States); Bachas, Leonidas G. [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States)], E-mail: bachas@uky.edu

    2008-04-14

    Quantitative determinations of ions in a variety of media have been performed traditionally via one of three approaches: optical instrumental methods (e.g., atomic absorption, and inductively-coupled plasma-optical emission or mass spectrometry), 'wet' methods, or ion-selective sensors. Each of the approaches, though, possesses limitations including: power/reagent consumption and lack of portability for instrumental techniques; laborious sample-treatment steps for wet methods; and lack of selectivity and sensitivity with sensors when employed with complex samples. Microfluidic device have emerged as a solution to some of these challenges associated with ion analysis. Such systems can integrate multiple sample handling, calibration, and detection steps ('lab-on-a-chip' concept) into a footprint amenable to portability, while requiring small amounts of sample and power. Furthermore, devices can be constructed for multi-analyte detection, either through multiple parallel fluidic architectures or by using arrays of detection elements. This paper reviews recent progress in the development of total-analysis systems for ionic species. Fabrication techniques and various fluid-handling operations are discussed briefly, followed by a number of more mature strategies for microfluidic ion analysis. A variety of approaches expected to comprise the next generation of devices are also presented.

  3. Improved Ion-Channel Biosensors

    Science.gov (United States)

    Nadeau, Jay; White, Victor; Dougherty, Dennis; Maurer, Joshua

    2004-01-01

    An effort is underway to develop improved biosensors of a type based on ion channels in biomimetic membranes. These sensors are microfabricated from silicon and other materials compatible with silicon. As described, these sensors offer a number of advantages over prior sensors of this type.

  4. Future relativistic heavy ion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, H.G.

    1980-12-01

    Equations of state for nuclear matter and ongoing experimental studies are discussed. Relativistic heavy ion physics is the only opportunity to study in the laboratory the properties of extended multiquark systems under conditions such that quarks might run together into new arrangements previously unobserved. Several lines of further study are mentioned. (GHT)

  5. Doped to Rare Earth Ions

    African Journals Online (AJOL)

    In the present work, we are interested by studying the spectroscopic properties for optical applications, mainly laser amplification, of MF2 crystals, where M is an alkaline earth (Ba, Sr) or Cadmium (Cd) doped with rare earth ions (Tb3+, Er3+, Ho3+. So far, we present the absorption and emission properties and also the ...

  6. Quantum Games in ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Buluta, Iulia Maria [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: noa@lyman.q.t.u-tokyo.ac.jp; Fujiwara, Shingo [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: fujiwara@lyman.q.t.u-tokyo.ac.jp; Hasegawa, Shuichi [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: hasegawa@q.t.u-tokyo.ac.jp

    2006-10-09

    We propose a general, scalable framework for implementing two-choices-multiplayer Quantum Games in ion traps. In particular, we discuss two famous examples: the Quantum Prisoners' Dilemma and the Quantum Minority Game. An analysis of decoherence due to intensity fluctuations in the applied laser fields is also provided.

  7. Ion Channels in Brain Metastasis.

    Science.gov (United States)

    Klumpp, Lukas; Sezgin, Efe C; Eckert, Franziska; Huber, Stephan M

    2016-09-08

    Breast cancer, lung cancer and melanoma exhibit a high metastatic tropism to the brain. Development of brain metastases severely worsens the prognosis of cancer patients and constrains curative treatment options. Metastasizing to the brain by cancer cells can be dissected in consecutive processes including epithelial-mesenchymal transition, evasion from the primary tumor, intravasation and circulation in the blood, extravasation across the blood-brain barrier, formation of metastatic niches, and colonization in the brain. Ion channels have been demonstrated to be aberrantly expressed in tumor cells where they regulate neoplastic transformation, malignant progression or therapy resistance. Moreover, many ion channel modulators are FDA-approved drugs and in clinical use proposing ion channels as druggable targets for future anti-cancer therapy. The present review article aims to summarize the current knowledge on the function of ion channels in the different processes of brain metastasis. The data suggest that certain channel types involving voltage-gated sodium channels, ATP-release channels, ionotropic neurotransmitter receptors and gap junction-generating connexins interfere with distinct processes of brain metastazation.

  8. Ion Channels in Brain Metastasis

    Directory of Open Access Journals (Sweden)

    Lukas Klumpp

    2016-09-01

    Full Text Available Breast cancer, lung cancer and melanoma exhibit a high metastatic tropism to the brain. Development of brain metastases severely worsens the prognosis of cancer patients and constrains curative treatment options. Metastasizing to the brain by cancer cells can be dissected in consecutive processes including epithelial–mesenchymal transition, evasion from the primary tumor, intravasation and circulation in the blood, extravasation across the blood–brain barrier, formation of metastatic niches, and colonization in the brain. Ion channels have been demonstrated to be aberrantly expressed in tumor cells where they regulate neoplastic transformation, malignant progression or therapy resistance. Moreover, many ion channel modulators are FDA-approved drugs and in clinical use proposing ion channels as druggable targets for future anti-cancer therapy. The present review article aims to summarize the current knowledge on the function of ion channels in the different processes of brain metastasis. The data suggest that certain channel types involving voltage-gated sodium channels, ATP-release channels, ionotropic neurotransmitter receptors and gap junction-generating connexins interfere with distinct processes of brain metastazation.

  9. Studies of the hydroxyborohydride and triborohydride ions

    Energy Technology Data Exchange (ETDEWEB)

    Reed, J.

    1977-10-01

    Results of the following studies are reported: chemical synthesis of hydroxytrihydroborate and peroxynitrite; the reduction of organic compounds with the hydroxyborohydride ion; and a kinetic study of the hydrolysis of the octahydrotriborate ions. (LK)

  10. Scaling ion traps for quantum computing

    CSIR Research Space (South Africa)

    Uys, H

    2010-09-01

    Full Text Available The design, fabrication and preliminary testing of a chipscale, multi-zone, surface electrode ion trap is reported. The modular design and fabrication techniques used are anticipated to advance scalability of ion trap quantum computing architectures...

  11. Divergent Field Annular Ion Engine Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed work investigates an approach that would allow an annular ion engine geometry to achieve ion beam currents approaching the Child-Langmuir limit. In this...

  12. Additive Manufacturing of Ion Thruster Optics Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Plasma Controls will manufacture and test a set of ion optics for electric propulsion ion thrusters using additive manufacturing technology, also known as 3D...

  13. Metal ions, Alzheimer's disease and chelation therapy

    National Research Council Canada - National Science Library

    Budimir, Ana

    2011-01-01

    .... In contrast to the direct chelation approach in metal ion overload disorders, in neurodegeneration the goal seems to be a better and subtle modulation of metal ion homeostasis, aimed at restoring ionic balance...

  14. Lithium-Ion Battery Program Status

    Science.gov (United States)

    Surampudi, S.; Huang, C. K.; Smart, M.; Davies, E.; Perrone, D.; Distefano, S.; Halpert, G.

    1996-01-01

    The objective of this program is to develop rechargeable Li-ion cells for future NASA missions. Applications that would benefit from this project are: new millenium spacecraft; rovers; landers; astronaut equipment; and planetary orbiters. The approach of this program is: select electrode materials and electrolytes; identify failure modes and mechanisms and enhance cycle life; demonstrate Li-ion cell technology with liquid electrolyte; select candidate polymer electrolytes for Li-ion polymer cells; and develop Li-ion polymer cell technology.

  15. From heavy ions to exotic atoms

    OpenAIRE

    Indelicato, Paul; Trassinelli, Martino

    2005-01-01

    We review a number of experiments and theoretical calculations on heavy ions and exotic atoms, which aim at providing informations on fundamental interactions. Among those are propositions of experiments for parity violation measurements in heavy ions and high-precision mesurements of He-like transition energies in highly charged ions. We also describe recent experiments on pionic atoms, that make use of highly-charged ion transitions to obtain accurate measurements of strong interaction shif...

  16. Ion-batterier - "The Next Generation"

    DEFF Research Database (Denmark)

    Søndergaard, Martin; Becker, Jacob; Shen, Yanbin

    2014-01-01

    Lithium-ion batterier er strømkilden, der har revolutioneret vores transportable elektronik. Familien af ion-batterier er imidlertid større end som så og har meget, meget mere at byde på.......Lithium-ion batterier er strømkilden, der har revolutioneret vores transportable elektronik. Familien af ion-batterier er imidlertid større end som så og har meget, meget mere at byde på....

  17. Negative ions produced in multicharged ions and C60 collisions

    Science.gov (United States)

    Martin, S.; Salmoun, A.; Brédy, R.; Montagne, G.; Bernard, J.; Ma, X.; Chen, L.

    2011-06-01

    We have measured the differential cross-sections in F3+-C60 collisions at low velocity (v=0.18 a.u.). Using coincidence measurements between the ejected electron number and recoil ions, we have estimated the initial charge state of C60 parent ions associated with neutral outgoing projectiles to range from 4+ to 7+. We found that the formation of anions is correlated with the strong excitation of C60 (average excitation energy about 160 eV). The cross-section of the production of the anion has been found to be 25 a.u. This value is in agreement with the scenario of anion formation in two steps. In the first step, F3+ ions are neutralized by multicollision on the C60 surface. In the second step and at the exit part of the collision, the electron attachment process occurs. For the production of a stable anion, the capture of electrons on carbon must occur directly to the ground states of F-, giving many electron vacancies on C60. This process explains the observation of strong electronic and vibronic excitations of C60 leading to electron emission and multifragmentation processes.

  18. Ion-optically driven depth compensation for ion beam tracking

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhri, Naved; Saito, Nami; Bert, Christoph; Franczak, Bernhard; Durante, Marco; Schardt, Dieter [GSI, Abt. Biophysik, Darmstadt (Germany); Rietzel, Eike [Siemens Healthcare, Particle Therapy, Erlangen (Germany)

    2009-07-01

    The beam delivery system for scanned carbon ion beam radiotherapy at GSI has been extended in research mode to irradiate moving targets. For beam tracking, the ion beam is adapted laterally as well as in range corresponding to the target's three dimensional (3D) motion. A beam tracking system with a motorized double wedge system for fast and accurate range adaptation has been developed. In addition to the current range adaptation system a much faster method for online energy modulation is being investigated where a fine focused ion beam is dynamically positioned, controlled by fast dipole magnets, on a small static wedge shaped absorber within the beam line. Experiments were performed at the therapy beam line to study the beam shift from central axis by the first dipole magnet up to the maximum limit where the beam can be deflected back to central axis by the second dipole magnet. Beam profiles were measured at different locations of the beam delivery system. The particle transmission was measured as well at the target position. Experiments were supported by Monte Carlo simulations for energy variation studies and for assessing the influence on beam profiles using MOCADI code.

  19. On ion escape from Venus

    Science.gov (United States)

    Jarvinen, R.

    2011-04-01

    This doctoral thesis is about the solar wind influence on the atmosphere of the planet Venus. A numerical plasma simulation model was developed for the interaction between Venus and the solar wind to study the erosion of charged particles from the Venus upper atmosphere. The developed model is a hybrid simulation where ions are treated as particles and electrons are modelled as a fluid. The simulation was used to study the solar wind induced ion escape from Venus as observed by the European Space Agency's Venus Express and NASA's Pioneer Venus Orbiter spacecraft. Especially, observations made by the ASPERA-4 particle instrument onboard Venus Express were studied. The thesis consists of an introductory part and four peer-reviewed articles published in scientific journals. In the introduction Venus is presented as one of the terrestrial planets in the Solar System and the main findings of the work are discussed within the wider context of planetary physics.Venus is the closest neighbouring planet to the Earth and the most earthlike planet in its size and mass orbiting the Sun. Whereas the atmosphere of the Earth consists mainly of nitrogen and oxygen, Venus has a hot carbon dioxide atmosphere, which is dominated by the greenhouse effect. Venus has all of its water in the atmosphere, which is only a fraction of the Earth's total water supply. Since planets developed presumably in similar conditions in the young Solar System, why Venus and Earth became so different in many respects?One important feature of Venus is that the planet does not have an intrinsic magnetic field. This makes it possible for the solar wind, a continuous stream of charged particles from the Sun, to flow close to Venus and to pick up ions from the planet's upper atmosphere. The strong intrinsic magnetic field of the Earth dominates the terrestrial magnetosphere and deflects the solar wind flow far away from the atmosphere. The region around Venus where the planet's atmosphere interacts with the

  20. Ion-exchange chromatographic protein refolding

    NARCIS (Netherlands)

    Freydell, E.; Wielen, van der L.; Eppink, M.H.M.; Ottens, M.

    2010-01-01

    The application of ion-exchange (IEX) chromatography to protein refolding (IExR) has been successfully proven, as supported by various studies using different model proteins, ion-exchange media and flow configurations. Ion-exchange refolding offers a relatively high degree of process

  1. Superconducting heavy-ion accelerating structures

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.

    1996-08-01

    This paper briefly reviews the technical history of superconducting ion-accelerating structures. Various superconducting cavities currently used and being developed for use in ion linacs are discussed. Principal parameters and operational characteristics of superconducting structures in active use at various heavy-ion facilities are described.

  2. Drift wave in pair-ion plasma

    Indian Academy of Sciences (India)

    ion plasma are discussed. It is shown that the temperature and/or mass difference of both species could produce drift wave in a pair-ion plasma. The results are discussed in the context of the fullerene pair-ion plasma experiment.

  3. Trapping and Sympathetic Cooling of Boron Ions

    CERN Document Server

    Rugango, Rene; Shu, Gang; Brown, Kenneth R

    2016-01-01

    We demonstrate the trapping and sympathetic cooling of B$^{+}$ ions in a Coulomb crystal of laser-cooled Ca$^{+}$, We non-destructively confirm the presence of the both B$^+$ isotopes by resonant excitation of the secular motion. The B$^{+}$ ions are loaded by ablation of boron and the secular excitation spectrum also reveals features consistent with ions of the form B$_{n}^{+}$.

  4. Nanofabrication with a helium ion microscope

    NARCIS (Netherlands)

    Maas, D.; Van Veldhoven, E.; Chen, P.; Sidorkin, V.; Salemink, H.; Van der Drift, E.; Alkemade, P.

    2009-01-01

    The recently introduced helium ion microscope (HIM) is capable of imaging and fabrication of nanostructures thanks to its sub-nanometer sized ion probe [1,2]. The unique interaction of the helium ions with the sample material provides very localized secondary electron emission, thus providing a

  5. Ion heat transport studies in JET

    DEFF Research Database (Denmark)

    Mantica, P; Angioni, C; Baiocchi, B

    2011-01-01

    Detailed experimental studies of ion heat transport have been carried out in JET exploiting the upgrade of active charge exchange spectroscopy and the availability of multi-frequency ion cyclotron resonance heating with 3He minority. The determination of ion temperature gradient (ITG) threshold a...

  6. Negative Halogen Ions for Fusion Applications

    Energy Technology Data Exchange (ETDEWEB)

    Grisham, L.R.; Kwan, J.W.; Hahto, S.K.; Hahto, S.T.; Leung, K.N.; Westenskow, G.

    2006-01-01

    Over the past quarter century, advances in hydrogen negative ion sources have extended the usable range of hydrogen isotope neutral beams to energies suitable for large magnetically confined fusion devices. Recently, drawing upon this experience, negative halogen ions have been proposed as an alternative to positive ions for heavy ion fusion drivers in inertial confinement fusion, because electron accumulation would be prevented in negative ion beams, and if desired, the beams could be photo-detached to neutrals. This paper reports the results of an experiment comparing the current density and beam emittance of Cl+ and Cl- extracted from substantially ion-ion plasmas with that of Ar+ extracted from an ordinary electron-ion plasma, all using the same source, extractor, and emittance scanner. At similar discharge conditions, the Cl- current was typically 85 – 90% of the positive chlorine current, with an e-/ Cl- ratio as low as seven without grid magnets. The Cl- was as much as 76% of the Ar+ current from a discharge with the same RF drive. The minimum normalized beam emittance and inferred ion temperatures of Cl+, Cl-, and Ar+ were all similar, so the current density and optical quality of Cl- appear as suitable for heavy ion fusion driver applications as a positive noble gas ion of similar mass. Since F, I, and Br should all behave similarly in an ion source, they should also be suitable as driver beams.

  7. The mean excitation energy of atomic ions

    DEFF Research Database (Denmark)

    Sauer, Stephan P. A.; Oddershede, Jens; Sabin, John R.

    2015-01-01

    A method for calculation of the mean excitation energies of atomic ions is presented, making the calculation of the energy deposition of fast ions to plasmas, warm, dense matter, and complex biological systems possible. Results are reported to all ions of helium, lithium, carbon, neon, aluminum, ...

  8. Improved Ion Optics for Introduction of Ions into a 9.4 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

    Science.gov (United States)

    Chen, Yu; Leach, Franklin E.; Kaiser, Nathan K.; Dang, Xibei; Ibrahim, Yehia M.; Norheim, Randolph V.; Anderson, Gordon A.; Smith, Richard D.; Marshall, Alan G.

    2014-01-01

    Enhancements to the ion source and transfer optics of our 9.4 T FT-ICR mass spectrometer have resulted in improved ion transmission efficiency for more sensitive mass measurement of complex mixtures at the MS and MS/MS levels. The tube lens/skimmer has been replaced by a dual ion funnel and the following octopole by a quadrupole for reduced ion cloud radial expansion before transmission into a mass-selective quadrupole. The number of ions that reach the ICR cell is increased by an order of magnitude for the funnel/quadrupole relative to the tube lens/skimmer/octopole. PMID:25601704

  9. Na Cl-ion pair association in water-DMSO mixtures: Effect of ion pair ...

    Indian Academy of Sciences (India)

    The physical picturethat emerges is that there is a strong contact ion pair (CIP) and strong to moderate solvent separated ion pair(SSIP) in these solutions. Analysis of local ion clusters shows that ions are dominantly solvated by watermolecules. The 12-6-1 potential model predicts running coordination numbers closest to ...

  10. Na Cl ion pair association in water-DMSO mixtures: Effect of ion pair ...

    Indian Academy of Sciences (India)

    ion pair in water–dimethyl sulfoxide (DMSO) mixtures for three DMSO mole fractions have been computed using constrained Molecular Dynamics (MD) simulations and confirmed by dynamical trajectories and residence times of the ion pair at various inter-ionic separations. The three ion-ion direct potentials used are 12-6-1 ...

  11. Heavy Ion Injection Into Synchrotrons, Based On Electron String Ion Sources

    CERN Document Server

    Donets, E E; Syresin, E M

    2004-01-01

    A possibility of heavy ions injection into synchrotrons is discussed on the base of two novel ion sources, which are under development JINR during last decade: 1) the electron string ion source (ESIS), which is a modified version of a conventional electron beam ion source (EBIS), working in a reflex mode of operation, and 2) the tubular electron string ion source (TESIS). The Electron String Ion Source "Krion-2" (VBLHE, JINR, Dubna) with an applied confining magnetic field of 3 T was used for injection into the superconducting JINR synchrotron - Nuclotron and during this runs the source provided a high pulse intensity of the highly charged ion beams: Ar16+

  12. Rechargeable Aluminum-Ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Paranthaman, Mariappan Parans [ORNL; Liu, Hansan [ORNL; Sun, Xiao-Guang [ORNL; Dai, Sheng [ORNL; Brown, Gilbert M [ORNL

    2015-01-01

    This chapter reports on the development of rechargeable aluminum-ion batteries. A possible concept of rechargeable aluminum/aluminum-ion battery based on low-cost, earth-abundant Al anode, ionic liquid EMImCl:AlCl3 (1-ethyl-3-methyl imidazolium chloroaluminate) electrolytes and MnO2 cathode has been proposed. Al anode has been reported to show good reversibility in acid melts. However, due to the problems in demonstrating the reversibility in cathodes, alternate battery cathodes and battery concepts have also been presented. New ionic liquid electrolytes for reversible Al dissolution and deposition are needed in the future for replacing corrosive EMImCl:AlCl3 electrolytes.

  13. Ion channelopathies and migraine pathogenesis.

    Science.gov (United States)

    Albury, Cassie L; Stuart, Shani; Haupt, Larisa M; Griffiths, Lyn R

    2017-08-01

    Migraine is a common neurological disorder that affects approximately 12-20% of the general adult population. Migraine pathogenesis is complex and not wholly understood. Molecular genetic investigations, imaging and biochemical studies, have unveiled a number of interconnected neurological pathways which seem to have a cause and effect component integral to its cause. Much weight of migraine attack initiation can be placed on the initial trigger and the pathways involved in its neuronal counter reaction. Ion channels play a large role in the generation, portrayal and mitigation of the brains response to external triggers. Several genetic studies have identified and implicated a number of ion channelopathy genes which may contribute to this generalised process. This review will focus on the genetics of migraine with particular emphasis placed on the potentially important role genes HEPH (responsible for iron transport and homeostasis) and KCNK18 (important for the transport and homeostasis of potassium) play in migraine cause.

  14. Semiholography for heavy ion collisions

    CERN Document Server

    Mukhopadhyay, Ayan

    2017-01-01

    The formation of QGP in heavy ion collisions gives us a great opportunity for learning about nonperturbative dynamics of QCD. Semiholography provides a new consistent framework to combine perturbative and non-perturbative effects in a coherent way and can be applied to obtain an effective description for heavy ion collisions. In particular, it allows us to include nonperturbative effects in existing glasma effective theory and QCD kinetic theory for the weakly coupled saturated degrees of freedom liberated by the collisions in the initial stages in a consistent manner. We argue why the full framework should be able to confront experiments with only a few phenomenological parameters and present feasibility tests for the necessary numerical computations. Furthermore, we discuss that semiholography leads to a new description of collective flow in the form of a generalised non-Newtonian fluid. We discuss some open questions which we hope to answer in the near future.

  15. Perspective on the Role of Negative Ions and Ion-Ion Plasmas in Heavy Ion Fusion Science, Magnetic Fusion Energy, and Related Fields

    Energy Technology Data Exchange (ETDEWEB)

    L. Grisham and J.W. Kwan

    2008-08-12

    Some years ago it was suggested that halogen negative ions [1] could offer a feasible alternative path to positive ions as a heavy ion fusion driver beam which would not suffer degradation due to electron accumulation in the accelerator and beam transport system, and which could be converted to a neutral beam by photodetachment near the chamber entrance if desired. Since then, experiments have demonstrated that negative halogen beams can be extracted and accelerated away from the gas plume near the source with a surviving current density close to what could be achieved with a positive ion of similar mass, and with comparable optical quality. In demonstrating the feasibility of halogen negative ions as heavy ion driver beams, ion - ion plasmas, an interesting and somewhat novel state of matter, were produced. These plasmas, produced near the extractor plane of the sources, appear, based upon many lines of experimental evidence, to consist of almost equal densities of positive and negative chlorine ions, with only a small component of free electrons. Serendipitously, the need to extract beams from this plasma for driver development provides a unique diagnostic tool to investigate the plasma, since each component - positive ions, negative ions, and electrons -- can be extracted and measured separately. We discuss the relevance of these observations to understanding negative ion beam extraction from electronegative plasmas such as halogens, or the more familiar hydrogen of magnetic fusion ion sources. We suggest a concept which might improve negative hydrogen extraction by the addition of a halogen. The possibility and challenges of producing ion-ion plasmas with thin targets of halogens or, perhaps, salt, is briefly addressed.

  16. Perspective on the Role of Negative Ions and Ion-Ion Plasmas in Heavy Ion Fusion Science, Magnetic Fusion Energy,and Related Fields

    Energy Technology Data Exchange (ETDEWEB)

    Grisham, L. R.; Kwan, J. W.

    2008-08-01

    Some years ago it was suggested that halogen negative ions could offer a feasible alternative path to positive ions as a heavy ion fusion driver beam which would not suffer degradation due to electron accumulation in the accelerator and beam transport system, and which could be converted to a neutral beam by photodetachment near the chamber entrance if desired. Since then, experiments have demonstrated that negative halogen beams can be extracted and accelerated away from the gas plume near the source with a surviving current density close to what could be achieved with a positive ion of similar mass, and with comparable optical quality. In demonstrating the feasibility of halogen negative ions as heavy ion driver beams, ion - ion plasmas, an interesting and somewhat novel state of matter, were produced. These plasmas, produced near the extractor plane of the sources, appear, based upon many lines of experimental evidence, to consist of almost equal densities of positive and negative chlorine ions, with only a small component of free electrons. Serendipitously, the need to extract beams from this plasma for driver development provides a unique diagnostic tool to investigate the plasma, since each component - positive ions, negative ions, and electrons - can be extracted and measured separately. We discuss the relevance of these observations to understanding negative ion beam extraction from electronegative plasmas such as halogens, or the more familiar hydrogen of magnetic fusion ion sources. We suggest a concept which might improve negative hydrogen extraction by the addition of a halogen. The possibility and challenges of producing ion - ion plasmas with thin targets of halogens or, perhaps, salt, is briefly addressed.

  17. Perspective on the Role of Negative Ions and Ion-Ion Plasmas in Heavy Ion Fusion Science, Magnetic Fusion Energy, and Related Fields

    Energy Technology Data Exchange (ETDEWEB)

    Grisham, L.R.; Kwan, J.W.

    2008-08-01

    Some years ago it was suggested that halogen negative ions [1]could offer a feasible alternative path to positive ions as a heavy ion fusion driver beam which would not suffer degradation due to electron accumulation in the accelerator and beam transport system, and which could be converted to a neutral beam by photodetachment near the chamber entrance if desired. Since then, experiments have demonstrated that negative halogen beams can be extracted and accelerated away from the gas plume near the source with a surviving current density close to what could be achieved with a positive ion of similar mass, and with comparable optical quality. In demonstrating the feasibility of halogen negative ions as heavy ion driver beams, ion - ion plasmas, an interesting and somewhat novel state of matter, were produced. These plasmas, produced near the extractor plane of the sources, appear, based upon many lines of experimental evidence, to consist of almost equal densities of positive and negative chlorine ions, with only a small component of free electrons. Serendipitously, the need to extract beams from this plasma for driver development provides a unique diagnostic tool to investigate the plasma, since each component - positive ions, negative ions, and electrons -- can be extracted and measured separately. We discuss the relevance of these observations to understanding negative ion beam extraction from electronegative plasmas such as halogens, or the more familiar hydrogen of magnetic fusion ion sources. We suggest a concept which might improve negative hydrogen extraction by the addition of a halogen. The possibility and challenges of producing ion-ion plasmas with thin targets of halogens or, perhaps, salt, is briefly addressed.

  18. Electrically controlled cesium ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Lilga, M. [Pacific Northwest Lab., Richland, WA (United States)

    1996-10-01

    Several sites within the DOE complex (Savannah River, Idaho, Oak Ridge and Hanford) have underground storage tanks containing high-level waste resulting from nuclear engineering activities. To facilitate final disposal of the tank waste, it is advantageous to separate and concentrate the radionuclides for final immobilization in a vitrified glass matrix. This task proposes a new approach for radionuclide separation by combining ion exchange (IX) and electrochemistry to provide a selective and economic separation method.

  19. Chromosome Aberrations by Heavy Ions

    Science.gov (United States)

    Ballarini, Francesca; Ottolenghi, Andrea

    It is well known that mammalian cells exposed to ionizing radiation can show different types of chromosome aberrations (CAs) including dicentrics, translocations, rings, deletions and complex exchanges. Chromosome aberrations are a particularly relevant endpoint in radiobiology, because they play a fundamental role in the pathways leading either to cell death, or to cell conversion to malignancy. In particular, reciprocal translocations involving pairs of specific genes are strongly correlated (and probably also causally-related) with specific tumour types; a typical example is the BCR-ABL translocation for Chronic Myeloid Leukaemia. Furthermore, aberrations can be used for applications in biodosimetry and more generally as biomarkers of exposure and risk, that is the case for cancer patients monitored during Carbon-ion therapy and astronauts exposed to space radiation. Indeed hadron therapy and astronauts' exposure to space radiation represent two of the few scenarios where human beings can be exposed to heavy ions. After a brief introduction on the main general features of chromosome aberrations, in this work we will address key aspects of the current knowledge on chromosome aberration induction, both from an experimental and from a theoretical point of view. More specifically, in vitro data will be summarized and discussed, outlining important issues such as the role of interphase death/mitotic delay and that of complex-exchange scoring. Some available in vivo data on cancer patients and astronauts will be also reported, together with possible interpretation problems. Finally, two of the few available models of chromosome aberration induction by ionizing radiation (including heavy ions) will be described and compared, focusing on the different assumptions adopted by the authors and on how these models can deal with heavy ions.

  20. Holifield Heavy Ion Research Facility

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.; Alton, G.D.; Ball, J.B.; Biggerstaff, J.A.; Dowling, D.T.; Erb, K.A.; Haynes, D.L.; Hoglund, D.E.; Hudson, E.D.; Juras, R.C.

    1986-02-15

    The Holifield Heavy Ion Research Facility has been in routine operation since July 1982. Beams have been provided using both the tandem accelerator alone and a coupled mode in which the Oak Ridge Isochronous Cyclotron is used as an energy booster for tandem beams. The coupled mode has proved to be especially effective and has allowed us to provide a wide range of energetic beams for scheduled experiments. In this report we discuss our operational experience and recent development activities.

  1. Holifield Heavy Ion Research Facility

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.; Alton, G.D.; Ball, J.B.; Biggerstaff, J.A.; Dowling, D.T.; Erb, K.A.; Haynes, D.L.; Hoglund, D.E.; Hudson, E.D.; Juras, R.C.

    1985-01-01

    The Holifield Heavy Ion Research Facility has been in routine operation since July 1982. Beams have been provided using both the tandem accelerator alone and a coupled mode in which the Oak Ridge Isochronous Cyclotron is used as an energy booster for tandem beams. The coupled mode has proved to be especially effective and has allowed us to provide a wide range of energetic beams for scheduled experiments. In this report we discuss our operational experience and recent development activities.

  2. Optically pumped polarized ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Zelenski, A.N.

    1995-12-31

    Polarization transfer collisions between protons, atomic hydrogen, or deuterium and optically pumped alkali-metal vapour are implemented in the high current optically pumped polarized ion source (OPPIS) and the laser driven source (LDS) of nuclear polarized atoms for target applications. The OPPIS technique overcomes the limitations on intensity of the conventional atomic beam source technique and meets the requirements of the new generation of polarization experiments at multi-GeV accelerators and colliders. 17 refs., 3 figs.

  3. Asymmetric Ion-Pairing Catalysis

    Science.gov (United States)

    Brak, Katrien

    2014-01-01

    Charged intermediates and reagents are ubiquitous in organic transformations. The interaction of these ionic species with chiral neutral, anionic, or cationic small molecules has emerged as a powerful strategy for catalytic, enantioselective synthesis. This review describes developments in the burgeoning field of asymmetric ion-pairing catalysis with an emphasis on the insights that have been gleaned into the structural and mechanistic features that contribute to high asymmetric induction. PMID:23192886

  4. Electrolytes for lithium ion batteries

    Science.gov (United States)

    Vaughey, John; Jansen, Andrew N.; Dees, Dennis W.

    2014-08-05

    A family of electrolytes for use in a lithium ion battery. The genus of electrolytes includes ketone-based solvents, such as, 2,4-dimethyl-3-pentanone; 3,3-dimethyl 2-butanone(pinacolone) and 2-butanone. These solvents can be used in combination with non-Lewis Acid salts, such as Li.sub.2[B.sub.12F.sub.12] and LiBOB.

  5. Heavy-ion Physics (ATLAS)

    CERN Document Server

    Przybycien, Mariusz; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment at the Large Hadron Collider has undertaken a broad physics program to probe and characterize the hot nuclear matter created in relativistic heavy-ion collisions. This talk presents recent results on production of electroweak bosons and quarkonium, charged particles and jets, bulk particle collectivity and electromagnetic processes in ultra-peripheral collisions, from Pb+Pb and p+Pb collisions.

  6. Intracellular ion channels and cancer.

    Science.gov (United States)

    Leanza, Luigi; Biasutto, Lucia; Managò, Antonella; Gulbins, Erich; Zoratti, Mario; Szabò, Ildikò

    2013-09-03

    Several types of channels play a role in the maintenance of ion homeostasis in subcellular organelles including endoplasmatic reticulum, nucleus, lysosome, endosome, and mitochondria. Here we give a brief overview of the contribution of various mitochondrial and other organellar channels to cancer cell proliferation or death. Much attention is focused on channels involved in intracellular calcium signaling and on ion fluxes in the ATP-producing organelle mitochondria. Mitochondrial K(+) channels (Ca(2+)-dependent BKCa and IKCa, ATP-dependent KATP, Kv1.3, two-pore TWIK-related Acid-Sensitive K(+) channel-3 (TASK-3)), Ca(2+) uniporter MCU, Mg(2+)-permeable Mrs2, anion channels (voltage-dependent chloride channel VDAC, intracellular chloride channel CLIC) and the Permeability Transition Pore (MPTP) contribute importantly to the regulation of function in this organelle. Since mitochondria play a central role in apoptosis, modulation of their ion channels by pharmacological means may lead to death of cancer cells. The nuclear potassium channel Kv10.1 and the nuclear chloride channel CLIC4 as well as the endoplasmatic reticulum (ER)-located inositol 1,4,5-trisphosphate (IP3) receptor, the ER-located Ca(2+) depletion sensor STIM1 (stromal interaction molecule 1), a component of the store-operated Ca(2+) channel and the ER-resident TRPM8 are also mentioned. Furthermore, pharmacological tools affecting organellar channels and modulating cancer cell survival are discussed. The channels described in this review are summarized on Figure 1. Overall, the view is emerging that intracellular ion channels may represent a promising target for cancer treatment.

  7. Intracellular ion channels and cancer

    Directory of Open Access Journals (Sweden)

    Luigi eLeanza

    2013-09-01

    Full Text Available Several types of channels play a role in the maintenance of ion homeostasis in subcellular organelles including endoplasmatic reticulum, nucleus, lysosome, endosome and mitochondria. Here we give a brief overview of the contribution of various mitochondrial and other organellar channels to cancer cell proliferation or death. Much attention is focused on channels involved in intracellular calcium signaling and on ion fluxes in the ATP-producing organelle mitochondria. Mitochondrial K+ channels (Ca2+-dependent BKCa and IKCa, ATP-dependent KATP, Kv1.3, two-pore TWIK-related Acid-Sensitive K+ channel-3 (TASK-3, Ca2+ uniporter MCU, Mg2+-permeable Mrs2, anion channels (voltage-dependent chloride channel VDAC, intracellular chloride channel CLIC and the Permeability Transition Pore (MPTP contribute importantly to the regulation of function in this organelle. Since mitochondria play a central role in apoptosis, modulation of their ion channels by pharmacological means may lead to death of cancer cells. The nuclear potassium channel Kv10.1 and the nuclear chloride channel CLIC4 as well as the endoplasmatic reticulum (ER-located inositol 1,4,5-trisphosphate (IP3 receptor, the ER-located Ca2+ depletion sensor STIM1 (stromal interaction molecule 1, a component of the store-operated Ca2+ channel and the ER-resident TRPM8 are also mentioned. Furthermore, pharmacological tools affecting organellar channels and modulating cancer cell survival are discussed. The channels described in this review are summarized on Figure 1. Overall, the view is emerging that intracellular ion channels may represent a promising target for cancer treatment.

  8. Ion-Pumping Microbial Rhodopsins

    Directory of Open Access Journals (Sweden)

    Hideki eKandori

    2015-09-01

    Full Text Available Rhodopsins are light-sensing proteins used in optogenetics. The word rhodopsin originates from the Greek words rhodo and opsis, indicating rose and sight, respectively. Although the classical meaning of rhodopsin is the red-colored pigment in our eyes, the modern meaning of rhodopsin encompasses photoactive proteins containing a retinal chromophore in animals and microbes. Animal and microbial rhodopsins possess 11-cis and all-trans retinal, respectively, to capture light in seven transmembrane α-helices, and photoisomerizations into all-trans and 13-cis forms, respectively, initiate each function. Ion-transporting proteins can be found in microbial rhodopsins, such as light-gated channels and light-driven pumps, which are the main tools in optogenetics. Light-driven pumps, such as archaeal H+ pump bacteriorhodopsin (BR and Cl- pump halorhodopsin (HR, were discovered in the 1970s, and their mechanism has been extensively studied. On the other hand, different kinds of H+ and Cl- pumps have been found in marine bacteria, such as proteorhodopsin (PR and Fulvimarina pelagi rhodopsin (FR, respectively. In addition, a light-driven Na+ pump was found, Krokinobacter eikastus rhodopsin 2 (KR2. These light-driven ion-pumping microbial rhodopsins are classified as DTD, TSA, DTE, NTQ and NDQ rhodopsins for BR, HR, PR, FR and KR2, respectively. Recent understanding of ion-pumping microbial rhodopsins is reviewed in this paper.

  9. heavy ion acceleration at shocks

    Science.gov (United States)

    Shevchenko, V. I.; Galinsky, V.

    2009-12-01

    The theoretical study of alpha particle acceleration at a quasi-parallel shock due to interaction with Alfven waves self-consistently excited in both upstream and downstream regions was conducted using a scale-separation model [1]. The model uses conservation laws and resonance conditions to find where waves will be generated or dumped and hence particles will be pitch--angle scattered as well as the change of the wave energy due to instability or damping. It includes in consideration the total distribution function (the bulk plasma and high energy tail), so no any assumptions (e.g. seed populations, or some ad-hoc escape rate of accelerated particles) are required. In previous studies heavy ions were treated as perfect test particles, they only experienced the Alfven turbulence excited by protons and didn’t contribute to turbulence generation. In contrast to this approach, we consider the ion scattering on hydromagnetic turbulence generated by both protons and ions themselves. It is important for alpha particles with their relatively large mass-loading parameter that defines efficiency of the wave excitation by alpha particles. The energy spectra of alpha particles is found and compared with those obtained in test particle approximation. [1] Galinsky, V.L., and V.I. Shevchenko, Astrophys. J., 669, L109, 2007.

  10. Influence of ion charge on primary defects creation in crystals irradiated by ions

    CERN Document Server

    Altynov, V A

    2002-01-01

    The model of primary defects formation under ion irradiation of crystals is described. The model is based on suggestion that defects are created as a result of Coulomb repulsion of neighbouring atoms at crystalline lattice ionized by bombarding ions. The changes of average charge of ions and the charge distribution of ions versus the depth of ion penetration to crystal are taken into account. The results of calculations are presented

  11. DETERMINATION OF STRONTIUM IONS IN WATERS WITH A HIGH CONTENT OF SODIUM IONS

    OpenAIRE

    Tatiana Mitina; Nadejda Bondarenco; Diana Grigoras; Elena Botizat; Tudor Lupascu

    2015-01-01

    This paper reports on the influence of sodium ions on experimental determination of strontium ions concentration in waters with a high content of sodium ions by using emission flame photometry and atomic absorption spectroscopy. For the method of emission flame photometry it was shown that at a wavelength of 460.7 nm (spectral emission line of strontium) the emission is linearly dependent on the concentration of sodium ions. The greatest impact of high concentrations of sodium ions on the res...

  12. Experimental Observations of Ion Phase-Space Vortices

    DEFF Research Database (Denmark)

    Pécseli, Hans; Armstrong, R. J.; Trulsen, J.

    1981-01-01

    Experimental observations of ion phase-space vortices are reported. The ion phase-space vortices form in the region of heated ions behind electrostatic ion acoustic shocks. The results are in qualitative agreement with numerical and analytic studies.......Experimental observations of ion phase-space vortices are reported. The ion phase-space vortices form in the region of heated ions behind electrostatic ion acoustic shocks. The results are in qualitative agreement with numerical and analytic studies....

  13. Ion Exchange Formation via Sulfonated Bicomponent Nonwovens

    Science.gov (United States)

    Stoughton, Hannah L.

    For many years ion exchange resins were used to: remove heavy metals from water, recover materials from wastewater, and eliminate harmful gases from the air. While use of these resin beads dominates the ion exchange industry, the beads have limitations that should be considered when decisions are made to employ them. For instance, officials must balance the inherent zero sum surface area and porosity of the materials. This series of studies investigates the use of bicomponent nonwovens as a base substrate for producing high surface area ion exchange materials for the removal of heavy metal ions. Functionalized materials were produced in a two-step process: (1) PET/PE spunbond bicomponent fibers were fractured completely, producing the high surface area nonwoven to be used as the base ion exchange material, and (2) the conditions for functionalizing the PET fibers of the nonwoven webs were investigated where an epoxy containing monomer was grafted to the surface followed by sulfonation of the monomer. The functionalization reactions of the PET fibers were monitored based on: weight gain, FTIR, TOF-SIMS, and SEM. Ion exchange properties were evaluated using titration and copper ion removal capacity from test solutions. The relationship between web structure and removal efficiency of the metal ions was defined through a comparison of the bicomponent and homocomponent nonwovens for copper ion removal efficiency. The investigation revealed that utilizing the high surface area, fractured bicomponent nonwoven ion exchange materials with capacities comparable to commercially available ion exchange resins could be produced.

  14. Laser Ion Acceleration Toward Future Ion Beam Cancer Therapy - Numerical Simulation Sudy-

    CERN Document Server

    Kawata, Shigeo; Nagashima, Toshihiro; Takano, Masahiro; Barada, Daisuke; Kong, Qing; Gu, Yan Jun; Wang, Ping Xiao; Ma, Yan Yun; Wang, Wei Ming

    2013-01-01

    Ion beam has been used in cancer treatment, and has a unique preferable feature to deposit its main energy inside a human body so that cancer cell could be killed by the ion beam. However, conventional ion accelerator tends to be huge in its size and its cost. In this paper a future intense-laser ion accelerator is proposed to make the ion accelerator compact. An intense femtosecond pulsed laser was employed to accelerate ions. The issues in the laser ion accelerator include the energy efficiency from the laser to the ions, the ion beam collimation, the ion energy spectrum control, the ion beam bunching and the ion particle energy control. In the study particle computer simulations were performed to solve the issues, and each component was designed to control the ion beam quality. When an intense laser illuminates a target, electrons in the target are accelerated and leave from the target; temporarily a strong electric field is formed between the high-energy electrons and the target ions, and the target ions ...

  15. Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Hamid, Ahmed M.; Cox, Jonathan T.; Garimella, Venkata BS; Smith, Richard D.

    2017-01-19

    We describe two approaches based upon ion ‘elevator’ and ‘escalator’ components that allow moving ions to different levels in structures for lossless ion manipulations (SLIM). Guided by ion motion simulations we designed elevator and escalator components providing essentially lossless transmission in multi-level designs based upon ion current measurements. The ion elevator design allowed ions to efficiently bridge a 4 mm gap between levels. The component was integrated in a SLIM and coupled to a QTOF mass spectrometer using an ion funnel interface to evaluate the m/z range transmitted as compared to transmission within a level (e.g. in a linear section). Mass spectra for singly-charged ions of m/z 600-2700 produced similar mass spectra for both elevator and straight (linear motion) components. In the ion escalator design, traveling waves (TW) were utilized to transport ions efficiently between two SLIM levels. Ion current measurements and ion mobility (IM) spectrometry analysis illustrated that ions can be transported between TW-SLIM levels with no significant loss of either ions or IM resolution. These developments provide a path for the development of multilevel designs providing e.g. much longer IM path lengths, more compact designs, and the implementation of much more complex SLIM devices in which e.g. different levels may operate at different temperatures or with different gases.

  16. Beam losses in heavy ion drivers

    CERN Document Server

    Mustafin, E R; Hofmann, I; Spiller, P J

    2002-01-01

    While beam loss issues have hardly been considered in detail for heavy ion fusion scenarios, recent heavy ion machine developments in different labs (European Organization for Nuclear Research (CERN), Gesellschaft fur Schwerionenforschung (GSI), Institute for Theoretical and Experimental Physics (ITEP), Relativistic Heavy-Ion Collider (RHIC)) have shown the great importance of beam current limitations due to ion losses. Two aspects of beam losses in heavy ion accelerators are theoretically considered: (1) secondary neutron production due to lost ions, and (2) vacuum pressure instability due to charge exchange losses. Calculations are compared and found to be in good agreement with measured data. The application to a Heavy-Ion Driven Inertial Fusion (HIDIF) scenario is discussed. 12 Refs.

  17. Ion trap architectures and new directions

    Science.gov (United States)

    Siverns, James D.; Quraishi, Qudsia

    2017-12-01

    Trapped ion technology has seen advances in performance, robustness and versatility over the last decade. With increasing numbers of trapped ion groups worldwide, a myriad of trap architectures are currently in use. Applications of trapped ions include: quantum simulation, computing and networking, time standards and fundamental studies in quantum dynamics. Design of such traps is driven by these various research aims, but some universally desirable properties have lead to the development of ion trap foundries. Additionally, the excellent control achievable with trapped ions and the ability to do photonic readout has allowed progress on quantum networking using entanglement between remotely situated ion-based nodes. Here, we present a selection of trap architectures currently in use by the community and present their most salient characteristics, identifying features particularly suited for quantum networking. We also discuss our own in-house research efforts aimed at long-distance trapped ion networking.

  18. RF synchronized short pulse laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fuwa, Yasuhiro, E-mail: fuwa@kyticr.kuicr.kyoto-u.ac.jp; Iwashita, Yoshihisa; Tongu, Hiromu; Inoue, Shunsuke; Hashida, Masaki; Sakabe, Shuji [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Okamura, Masahiro [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Yamazaki, Atsushi [Graduate School of Engineering, Nagoya University, Nagoya, Aichi 464-8603 (Japan)

    2016-02-15

    A laser ion source that produces shortly bunched ion beam is proposed. In this ion source, ions are extracted immediately after the generation of laser plasma by an ultra-short pulse laser before its diffusion. The ions can be injected into radio frequency (RF) accelerating bucket of a subsequent accelerator. As a proof-of-principle experiment of the ion source, a RF resonator is prepared and H{sub 2} gas was ionized by a short pulse laser in the RF electric field in the resonator. As a result, bunched ions with 1.2 mA peak current and 5 ns pulse length were observed at the exit of RF resonator by a probe.

  19. Microvillar ion channels: cytoskeletal modulation of ion fluxes.

    Science.gov (United States)

    Lange, K

    2000-10-21

    The recently presented theory of microvillar Ca(2+)signaling [Lange, K. (1999) J. Cell. Physiol.180, 19-35], combined with Manning's theory of "condensed counterions" in linear polyelectrolytes [Manning, G. S. (1969). J. Chem. Phys.51, 924-931] and the finding of cable-like ion conductance in actin filaments [Lin, E. C. & Cantiello, H. F. (1993). Biophys. J.65, 1371-1378], allows a systematic interpretation of the role of the actin cytoskeleton in ion channel regulation. Ion conduction through actin filament bundles of microvilli exhibits unique nonlinear transmission properties some of which closely resemble that of electronic semiconductors: (1) bundles of microfilaments display significant resistance to cation conduction and (2) this resistance is decreased by supply of additional energy either as thermal, mechanical or electromagnetic field energy. Other transmission properties, however, are unique for ionic conduction in polyelectrolytes. (1) Current pulses injected into the filaments were transformed into oscillating currents or even into several discrete charge pulses closely resembling that of single-channel recordings. Discontinuous transmission is due to the existence of counterion clouds along the fixed anionic charge centers of the polymer, each acting as an "ionic capacitor". (2) The conductivity of linear polyelectrolytes strongly decreases with the charge number of the counterions; thus, Ca(2+)and Mg(2+)are effective modulator of charge transfer through linear polyelectrolytes. Field-dependent formation of divalent cation plugs on either side of the microvillar conduction line may generate the characteristic gating behavior of cation channels. (3) Mechanical movement of actin filament bundles, e.g. bending of hair cell microvilli, generates charge translocations along the filament structure (mechano-electrical coupling). (4) Energy of external fields, by inducing molecular dipoles within the polyelectrolyte matrix, can be transformed into mechanical

  20. Dual-Polarity Ion Trap Mass Spectrometry: Dynamic Monitoring and Controlling Gas-phase Ion-Ion Reactions

    Science.gov (United States)

    He, Muyi; Jiang, You; Guo, Dan; Xiong, Xingchuang; Fang, Xiang; Xu, Wei

    2017-07-01

    A dual-polarity linear ion trap (LIT) mass spectrometer was developed in this study, and the method for simultaneously controlling and detecting cations and anions was proposed and realized in the LIT. With the application of an additional dipolar DC field on the ejection electrodes of an LIT, dual-polarity mass spectra could be obtained, which include both the mass-to-charge ( m/z) ratio and charge polarity information of an ion. Compared with conventional method, the ion ejection and detection efficiency could also be improved by about one-fold. Furthermore, ion-ion reactions within the LIT could be dynamically controlled and monitored by manipulating the distributions of ions with opposite charge polarities. This method was then used to control and study the reaction kinetics of ion-ion reactions, including electron transfer dissociation (ETD) and charge inversion reactions. A dual-polarity collision-induced dissociation (CID) experiment was proposed and performed to enhance the sequence coverage of a peptide ion. Ion trajectory simulations were also carried out for concept validation and system optimization.

  1. Status report on electron cyclotron resonance ion sources at the Heavy Ion Medical Accelerator in Chiba

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Jincho, K; Okada, T; Yamamoto, M; Hattori, T G; Biri, S; Baskaran, R; Sakata, T; Sawada, K; Uno, K

    2000-01-01

    The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences (NIRS) is not only dedicated to cancer therapy, it is also utilized with various ion species for basic experiments of biomedical science, physics, chemistry, etc. Two electron cyclotron resonance (ECR) ion sources are installed for production of gaseous ions. One of them, the NIRS-ECR, is a 10 GHz ECR ion source, and is mainly operated to produce C/sup 4+/ ions for daily clinical treatment. This source realizes good reproducibility and reliability and it is easily operated. The other source, the NIRS-HEC, is an 18 GHz ECR ion source that is expected to produce heavier ion species. The output ion currents of the NIRS-ECR and the NIRS-HEC are 430e mu A for C/sup 4+/ and 1.1e mA for Ar/sup 8+/, respectively. (14 refs).

  2. Effect of ion clouds micromotion on measured signal in Fourier transform ion cyclotron resonance: Computer simulation.

    Science.gov (United States)

    Vladimirov, Gleb; Kostyukevich, Yury; Kharybin, Oleg; Nikolaev, Eugene

    2017-08-01

    Particle-in-cell-based realistic simulation of Fourier transform ion cyclotron resonance experiments could be used to generate ion trajectories and a signal induced on the detection electrodes. It has been shown recently that there is a modulation of "reduced" cyclotron frequencies in ion cyclotron resonance signal caused by Coulomb interaction of ion clouds. In this work it was proposed to use this modulation in order to determine frequency difference between an ion of known m/z and all other ions generating signal in ion cyclotron resonance cell. It is shown that with an increase of number of ions in ion cyclotron resonance trap, the modulation index increases, which lead to a decrease in the accuracy of determination of peak intensities by super Fourier transform resolution methods such as filter diagonalization method.

  3. Ion beam modification of solids ion-solid interaction and radiation damage

    CERN Document Server

    Wesch, Werner

    2016-01-01

    This book presents the method of ion beam modification of solids in realization, theory and applications in a comprehensive way. It provides a review of the physical basics of ion-solid interaction and on ion-beam induced structural modifications of solids. Ion beams are widely used to modify the physical properties of materials. A complete theory of ion stopping in matter and the calculation of the energy loss due to nuclear and electronic interactions are presented including the effect of ion channeling. To explain structural modifications due to high electronic excitations, different concepts are presented with special emphasis on the thermal spike model. Furthermore, general concepts of damage evolution as a function of ion mass, ion fluence, ion flux and temperature are described in detail and their limits and applicability are discussed. The effect of nuclear and electronic energy loss on structural modifications of solids such as damage formation, phase transitions and amorphization is reviewed for ins...

  4. Anthropogenic perturbations of tropospheric ion composition

    Science.gov (United States)

    Beig, G.; Brasseur, G.

    This paper presents a simple model of the vertical distribution of the most abundant positive ions in the troposphere. The model is based on a simple ion chemical scheme, measured rate constants, and observed or calculated atmospheric densities of parent neutral compounds. It suggests that in many cases the most abundant gaseous ions are heavy protonated water cluster ions of pyridine, picoline and lutidine with ammonia molecules attached (pyridinated cluster ions) in the lower troposphere (below 7 km altitude), acetone cluster ions in the upper troposphere (between 7 and 15 km) and methyl cyanide cluster ions above 15 km. The relative abundance of heavy clustered aerosol ions is predicted to be highest near the surface. The model suggests that ion composition could be perturbed as a result of human activities (i.e., increasing emissions of parent neutral species including alkaline compounds), and that in particular, the relative atmospheric abundance of pyridinated water cluster ions is increasing dramatically and should further increase in the future.

  5. Computational modeling of ion transport through nanopores

    Science.gov (United States)

    Modi, Niraj; Winterhalter, Mathias; Kleinekathöfer, Ulrich

    2012-09-01

    Nanoscale pores are ubiquitous in biological systems while artificial nanopores are being fabricated for an increasing number of applications. Biological pores are responsible for the transport of various ions and substrates between the different compartments of biological systems separated by membranes while artificial pores are aimed at emulating such transport properties. As an experimental method, electrophysiology has proven to be an important nano-analytical tool for the study of substrate transport through nanopores utilizing ion current measurements as a probe for the detection. Independent of the pore type, i.e., biological or synthetic, and objective of the study, i.e., to model cellular processes of ion transport or electrophysiological experiments, it has become increasingly important to understand the dynamics of ions in nanoscale confinements. To this end, numerical simulations have established themselves as an indispensable tool to decipher ion transport processes through biological as well as artificial nanopores. This article provides an overview of different theoretical and computational methods to study ion transport in general and to calculate ion conductance in particular. Potential new improvements in the existing methods and their applications are highlighted wherever applicable. Moreover, representative examples are given describing the ion transport through biological and synthetic nanopores as well as the high selectivity of ion channels. Special emphasis is placed on the usage of molecular dynamics simulations which already have demonstrated their potential to unravel ion transport properties at an atomic level.

  6. Spectroscopy with trapped highly charged ions

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P

    2008-01-23

    We give an overview of atomic spectroscopy performed on electron beam ion traps at various locations throughout the world. Spectroscopy at these facilities contributes to various areas of science and engineering, including but not limited to basic atomic physics, astrophysics, extreme ultraviolet lithography, and the development of density and temperature diagnostics of fusion plasmas. These contributions are accomplished by generating, for example, spectral surveys, making precise radiative lifetime measurements, accounting for radiative power emitted in a given wavelength band, illucidating isotopic effects, and testing collisional-radiative models. While spectroscopy with electron beam ion traps had originally focused on the x-ray emission from highly charged ions interacting with the electron beam, the operating modes of such devices have expanded to study radiation in almost all wavelength bands from the visible to the hard x-ray region; and at several facilities the ions can be studied even in the absence of an electron beam. Photon emission after charge exchange or laser excitation has been observed, and the work is no longer restricted to highly charged ions. Much of the experimental capabilities are unique to electron beam ion traps, and the work performed with these devices cannot be undertaken elsewhere. However, in other areas the work on electron beam ion traps rivals the spectroscopy performed with conventional ion traps or heavy-ion storage rings. The examples we present highlight many of the capabilities of the existing electron beam ion traps and their contributions to physics.

  7. Exploring Quantum Physics with Trapped Ions

    Science.gov (United States)

    Leibfried, Dietrich

    2017-04-01

    Trapped ions were among the first systems, where a single quantum particle can be confined and manipulated in almost perfect isolation from its environment. This makes ions prime candidates for high precision experiments and for demonstrating textbook quantum mechanical principles. Several ions in the same trap can couple strongly to each other through their Coulomb interaction. This enables entangling quantum logic gates and as a consequence, many experiments with trapped ions have concentrated on advancing quantum information processing in the last 20 years. While much work still needs to be done before a scalable, fault tolerant universal quantum processor can be realized in any system, the advances with ions have enabled exploration of new avenues, such as quantum simulation, quantum logic spectroscopy for ion clocks, and for molecular ion and highly charged ion spectroscopy. Lately, ion-based sensors and ideas for hybrid quantum systems that aim to couple trapped ions to photons, neutral atoms, superconducting circuits, micro-mechanical oscillators or other quantum coherent entities are gaining momentum.

  8. Novel electrostatic column for ion projection lithography

    Energy Technology Data Exchange (ETDEWEB)

    Chalupka, A.; Stengl, G.; Buschbeck, H.; Lammer, G.; Vonach, H.; Fischer, R.; Hammel, E.; Loeschner, H.; Nowak, R.; Wolf, P. (IMS - Ion Microfabrication Systems GmbH, A-1020 Vienna (Austria)); Finkelstein, W.; Hill, R.W. (Advanced Lithography Group, Columbia, Maryland 21045 (United States)); Berry, I.L. (Department of Defense, Microelectronics Research Laboratory, Columbia, Maryland 21045 (United States)); Harriott, L.R. (AT T Bell Laboratories, Murray Hill, New Jersey 07974 (United States)); Melngailis, J. (University of Maryland, College Park, Maryland 20742 (United States)); Randall, J.N. (Texas Instruments, Dallas, Texas 75243 (United States)); Wolfe, J.C. (University of Houston, Houston, Texas 77204 (United States)); Stroh, H.; Wollnik, H. (University of Giessen, D-35392 Giessen (Germany)); Mondelli, A.A.; Petillo, J.J. (Science Applications International Corporation, McLean, Virginia 22102 (United States)); Leung, K. (Lawrence Berkeley Laboratory, University of Californi

    1994-11-01

    Ion projection lithography (IPL) is being considered for high volume sub-0.25-[mu]m lithography. A novel ion-optical column has been designed for exposing 20[times]20 mm[sup 2] fields at 3[times] reduction from stencil mask to wafer substrates. A diverging lens is realized by using the stencil mask as the first electrode of the ion-optical column. The second and third electrode form an accelerating field lens. The aberrations of the first two lenses (diverging lens and field lens) are compensated by an asymmetric Einzel lens projecting an ion image of the stencil mask openings onto the wafer substrate with better than 2 mrad telecentricity. Less than 30 nm intrafield distortion was calculated within 20[times]20 mm[sup 2] exposure fields. The calculation uncertainty is estimated to be about 10 nm. The calculation holds for helium ions with [approx]10 keV ion energy at the stencil mask and 150 keV ion energy at the wafer plane. A virtual ion source size of 10 [mu]m has been assumed. The calculated chromatic aberrations are less than 60 nm, assuming 6 eV energy spread of the ions extracted from a duoplasmatron source. Recently a multicusp ion source has been developed for which preliminary results indicate an energy spread of less than 2 eV. Thus, with a multicusp source chromatic aberrations of less than 20 nm are to be expected. The ion energy at the crossover between the field lens and the asymmetric Einzel lens is 200 keV. Therefore, stochastic space charge induced degradations in resolution can be kept sufficiently low. The divergence of the ion image projected to the wafer plane is less than 2 mrad. Thus, the usable'' depth of focus for the novel ion optics is in the order of 10 [mu]m.

  9. IOOC Organizational Network (ION) Project

    Science.gov (United States)

    Dean, H.

    2013-12-01

    In order to meet the growing need for ocean information, research communities at the national and international levels have responded most recently by developing organizational frameworks that can help to integrate information across systems of existing networks and standardize methods of data gathering, management, and processing that facilitate integration. To address recommendations and identified challenges related to the need for a better understanding of ocean observing networks, members of the U.S. Interagency Ocean Observation Committee (IOOC) supported pursuing a project that came to be titled the IOOC Organizational Network (ION). The ION tool employs network mapping approaches which mirror approaches developed in academic literature aimed at understanding political networks. Researchers gathered data on the list of global ocean observing organizations included in the Framework for Ocean Observing (FOO), developed in 2012 by the international Task Team for an Integrated Framework for Sustained Ocean Observing. At the international scale, researchers reviewed organizational research plans and documents, websites, and formal international agreement documents. At the U.S. national scale, researchers analyzed legislation, formal inter-agency agreements, work plans, charters, and policy documents. Researchers based analysis of relationships among global organizations and national federal organizations on four broad relationship categories: Communications, Data, Infrastructure, and Human Resources. In addition to the four broad relationship categories, researchers also gathered data on relationship instrument types, strength of relationships, and (at the global level) ocean observing variables. Using network visualization software, researchers then developed a series of dynamic webpages. Researchers used the tool to address questions identified by the ocean observing community, including identifying gaps in global relationships and the types of tools used to

  10. Ion Mobility Spectrometer Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Nicholas [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; McLain, Derek [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Steeb, Jennifer [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2017-12-20

    The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

  11. Mutation induction by ion beams in plants

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Atsushi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2001-03-01

    The effect of ion beams such as C, He, and Ne ions was investigated on the mutation induction in plants with the expectation that ion beams of high linear energy transfer (LET) can frequently produce large DNA alternation such as inversion, translocation and large deletion rather than point mutation. Mutation frequency was investigated using Arabidopsis visible phenotype loci and was 8 to 33 fold higher for 220 MeV carbon ions than for electrons. Mutation spectrum was investigated on the flower color of chrysanthemum cv to find that flower mutants induced by ion beams show complex and stripe types rather than single color. Polymerase chain reaction analysis was performed to investigate DNA alteration of mutations. In conclusion, the characteristics of ion beams for the mutation induction are 1) high frequency, 2) broad mutation spectrum, and 3) novel mutants. (S. Ohno)

  12. High-Resolution Ion Cyclotron Mobility Spectrometry

    Science.gov (United States)

    Merenbloom, Samuel I.; Glaskin, Rebecca S.; Henson, Zachary B.; Clemmer, David E.

    2009-01-01

    A novel ion mobility spectrometry instrument incorporating a cyclotron geometry drift tube is presented. The drift tube consists of eight regions, four curved drift tubes and four ion funnels. Packets of ions are propagated around the drift tube by changing the drift field at a frequency that is resonant with the ion’s drift time through each region. The approach trims each packet of ions as it leaves and enters each new region. An electrostatic gate allows ions to be kept in the drift tube for numerous cycles, increasing the ability to resolve specified ions. We demonstrate the approach by isolating the [M+2H]2+ or [M+3H]3+ charge state of substance P as well as individual trisaccharide isomers from a mixture of melezitose and raffinose. Resolving powers in excess of 300 are obtainable with this approach. PMID:19143495

  13. A Plasma Ion Source for ISOLTRAP

    CERN Document Server

    Skov, Thomas Guldager

    2016-01-01

    In this report, my work testing the new Penning ion source as a summer student at ISOLTRAP is described. The project was composed of three stages: (1) Setting up a test laboratory in building 275, (2) characterizing the ion source, and (3) implementing and testing the source in the ISOLTRAP setup. After setting up the test laboratory, the ion source was tested in a constant pressure environment with produced ion currents in the range of nA . An extensive scan of the source ion current versus operating parameters (pressure, voltage) was performed. A setup with pulsed gas flow was also tested, allowing a reduction of the gas load on the vacuum system. The behavior of the ion source together with the ISOLTRAP setup was also investigated, allowing to understand current limitations and future directions of improvement.

  14. Binding of Ca Ions by Paramecium caudatum

    Science.gov (United States)

    Naitoh, Yutaka; Yasumasu, Ikuo

    1967-01-01

    Binding of 45Ca by live Paramecium caudatum was determined under various external ionic conditions. It was found that calcium uptake was separable into at least two components, a rapid and a slow one. The rapid component was influenced by the presence of certain other ions in a manner which agrees with the law of mass action. It appears that an ion exchange system may be involved in a binding equilibrium established between Paramecium, Ca++, and certain other ions. K+, Rb+, and Ba++ in the equilibrium medium are among those ions which inhibit calcium uptake. It is proposed that liberation of Ca++ from binding sites on Paramecium by an exchange reaction with competing ions is the first step in the mechanism of ciliary reversal in the response to external application of these ions. PMID:6033587

  15. Microsecond pulsed hydrogen/deuterium exchange of electrosprayed ubiquitin ions stored in a linear ion trap.

    Science.gov (United States)

    Rajabi, Khadijeh

    2015-02-07

    A pulse of D2O vapour on the order of microseconds is allowed to react with the +6 to +9 charge states of ubiquitin confined in a linear ion trap (LIT). Two envelopes of peaks are detected for the ions of ubiquitin, corresponding to the ions that exchange more quickly and more slowly. The deuterium uptake of the protonated sites on ubiquitin ions accounts for the ion population with the fast exchange. The hydrogen/deuterium exchange (HDX) kinetics of ubiquitin ions trapped in the LIT for 200 ms showed comparable structural transitions to those trapped for 300 ms. When ions are trapped for longer, i.e. up to 2000 ms, mainly the slow exchanging ion population is detected. In all experiments the +7 ions exchange the most, suggesting a short distance between the surface protonated sites and nearby charged sites, and concomitantly high accessibility of surface protonated sites towards D2O. The +6 ions are more compact than the +7 ions but have one fewer protonated site, therefore fewer surface availabilities for D2O attack. The data suggest that the +6 ions keep most of their solution-phase contacts intact while the hydrophobic core is slightly interrupted in the +7 ions, possibly due to the exposure of charged His68 that is normally buried in the hydrophobic pocket. The +8 and +9 ions have more protonated sites but are less compact than the +7 ions because of Coulombic repulsion, resulting in a larger distance between the protonated sites and the basic sites. The data indicate that the HDX mechanism of ions with the slower exchange corresponding to the second envelope of peaks is primarily governed via a relay mechanism. The results suggest that the pulsed HDX MS method is sampling a population of ubiquitin ions with a similar backbone fold to the solution.

  16. LHC Report: Positive ion run!

    CERN Multimedia

    Mike Lamont for the LHC Team

    2011-01-01

    The current LHC ion run has been progressing very well. The first fill with 358 bunches per beam - the maximum number for the year - was on Tuesday, 15 November and was followed by an extended period of steady running. The quality of the beam delivered by the heavy-ion injector chain has been excellent, and this is reflected in both the peak and the integrated luminosity.   The peak luminosity in ATLAS reached 5x1026 cm-2s-1, which is a factor of ~16 more than last year's peak of 3x1025 cm-2s-1. The integrated luminosity in each of ALICE, ATLAS and CMS is now around 100 inverse microbarn, already comfortably over the nominal target for the run. The polarity of the ALICE spectrometer and solenoid magnets was reversed on Monday, 28 November with the aim of delivering another sizeable amount of luminosity in this configuration. On the whole, the LHC has been behaving very well recently, ensuring good machine availability. On Monday evening, however, a faulty level sensor in the cooling towe...

  17. LHC Report: Ions cross protons

    CERN Multimedia

    Reyes Alemany Fernandez for the LHC team

    2013-01-01

    The LHC starts the New Year facing a new challenge: proton-lead collisions in the last month before the shutdown in mid-February.    The first stable beams were achieved on 20 January with 13 individual bunches per beam. In the next fill, the first bunch-trains were injected and stable beams were achieved with 96 proton on 120 ion bunches.  This fill was very important because we were able to study the so-called moving long-range beam-beam encounters. Long-range encounters, which are also seen in proton-proton runs, occur when the bunches in the two beams “see” each other as they travel in the same vacuum chamber at either side of the experiments.  The situation becomes more complicated with proton-lead ions because the two species have different revolution times (until the frequencies are locked at top energy- see “Cogging exercises”) and thus these encounters move. We found that this effect does not cause significant beam losses...

  18. Heavy Ion Physics at CMS

    CERN Document Server

    Veres, Gabor

    2017-01-01

    In the present proceedings recent heavy ion results from the Compact Muon Solenoid collaboration at the LHC are presented. These contain comparisons between small and large collision systems, as well as studies of energy evolution, thus include data collected in proton-proton collisions at 13 TeV (2015 and 2016), proton-proton and lead-lead collisions at 5 TeV (2015), and proton-lead collisions at 5 TeV and 8 TeV (2016) center-of-mass energy per nucleon pair. They provide new insights into the properties of the extremely high density and high temperature matter created in heavy ion collisions, while pointing out similarities and differences in comparison to smaller collision systems. These include gluon distribution functions in the lead nucleus; the azimuthal anisotropy of final state particle distributions in all the three different collision systems; charge separation signals from proton-lead collisions and consequences for the Chiral Magnetic Effect; new studies of parton energy loss and its dependence on...

  19. Multifunctional scanning ion conductance microscopy.

    Science.gov (United States)

    Page, Ashley; Perry, David; Unwin, Patrick R

    2017-04-01

    Scanning ion conductance microscopy (SICM) is a nanopipette-based technique that has traditionally been used to image topography or to deliver species to an interface, particularly in a biological setting. This article highlights the recent blossoming of SICM into a technique with a much greater diversity of applications and capability that can be used either standalone, with advanced control (potential-time) functions, or in tandem with other methods. SICM can be used to elucidate functional information about interfaces, such as surface charge density or electrochemical activity (ion fluxes). Using a multi-barrel probe format, SICM-related techniques can be employed to deposit nanoscale three-dimensional structures and further functionality is realized when SICM is combined with scanning electrochemical microscopy (SECM), with simultaneous measurements from a single probe opening up considerable prospects for multifunctional imaging. SICM studies are greatly enhanced by finite-element method modelling for quantitative treatment of issues such as resolution, surface charge and (tip) geometry effects. SICM is particularly applicable to the study of living systems, notably single cells, although applications extend to materials characterization and to new methods of printing and nanofabrication. A more thorough understanding of the electrochemical principles and properties of SICM provides a foundation for significant applications of SICM in electrochemistry and interfacial science.

  20. Measurement of ultra-low ion energy of decelerated ion beam using a deflecting electric field

    Energy Technology Data Exchange (ETDEWEB)

    Thopan, P.; Suwannakachorn, D.; Tippawan, U. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@thep-center.org [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2015-12-15

    In investigation on ultra-low-energy ion bombardment effect on DNA, an ion beam deceleration lens was developed for high-quality ultra-low-energy ion beam. Measurement of the ion energy after deceleration was necessary to confirm the ion beam really decelerated as theoretically predicted. In contrast to conventional methods, this work used a simple deflecting electrostatic field after the deceleration lens to bend the ion beam. The beam bending distance depended on the ion energy and was described and simulated. A system for the measurement of the ion beam energy was constructed. It consisted of a pair of parallel electrode plates to generate the deflecting electrical field, a copper rod measurement piece to detect ion beam current, a vernier caliper to mark the beam position, a stepping motor to translate the measurement rod, and a webcam-camera to read the beam bending distance. The entire system was installed after the ion-beam deceleration lens inside the large chamber of the bioengineering vertical ion beam line. Moving the measurement rod across the decelerated ion beam enabled to obtain beam profiles, from which the beam bending distance could be known and the ion beam energy could be calculated. The measurement results were in good agreement with theoretical and simulated results.

  1. Electrochemical ion separation in molten salts

    Energy Technology Data Exchange (ETDEWEB)

    Spoerke, Erik David; Ihlefeld, Jon; Waldrip, Karen; Wheeler, Jill S.; Brown-Shaklee, Harlan James; Small, Leo J.; Wheeler, David R.

    2017-12-19

    A purification method that uses ion-selective ceramics to electrochemically filter waste products from a molten salt. The electrochemical method uses ion-conducting ceramics that are selective for the molten salt cations desired in the final purified melt, and selective against any contaminant ions. The method can be integrated into a slightly modified version of the electrochemical framework currently used in pyroprocessing of nuclear wastes.

  2. The Aarhus Ion Micro-Trap Project

    DEFF Research Database (Denmark)

    Miroshnychenko, Yevhen; Nielsen, Otto; Poulsen, Gregers

    and installed in an ultra high vacuum chamber, which includes an ablation oven for all-optical loading of the trap [2]. The next steps on the project are to demonstrate the operation of the micro-trap and the cooling of ions using fiber delivered light. [1] D. Grant, Development of Micro-Scale Ion traps, Master......As part of our involvement in the EU MICROTRAP project, we have designed, manufactured and assembled a micro-scale ion trap with integrated optical fibers. These prealigned fibers will allow delivering cooling laser light to single ions. Therefore, such a trap will not require any direct optical...

  3. Neutral beamline with improved ion energy recovery

    Science.gov (United States)

    Kim, Jinchoon

    1984-01-01

    A neutral beamline employing direct energy recovery of unneutralized residual ions is provided which enhances the energy recovery of the full energy ion component of the beam exiting the neutralizer cell, and thus improves the overall neutral beamline efficiency. The unneutralized full energy ions exiting the neutralizer are deflected from the beam path and the electrons in the cell are blocked by a magnetic field applied transverse to the beam direction in the neutral izer exit region. The ions which are generated at essentially ground potential and accelerated through the neutralizer cell by a negative acceleration voltage are collected at ground potential. A neutralizer cell exit end region is provided which allows the magnetic and electric fields acting on the exiting ions to be loosely coupled. As a result, the fractional energy ions exiting the cell are reflected onto and collected at an interior wall of the neutralizer formed by the modified end geometry, and thus do not detract from the energy recovery efficiency of full energy ions exiting the cell. Electrons within the neutralizer are prevented from exiting the neutralizer end opening by the action of crossed fields drift (ExB) and are terminated to a collector collar around the downstream opening of the neutralizer. The correct combination of the extended neutralizer end structure and the magnet region is designed so as to maximize the exit of full energy ions and to contain the fractional energy ions.

  4. Oxygen ions observed near Saturn's A ring.

    Science.gov (United States)

    Waite, J H; Cravens, T E; Ip, W-H; Kasprzak, W T; Luhmann, J G; McNutt, R L; Niemann, H B; Yelle, R V; Mueller-Wodarg, I; Ledvina, S A; Scherer, S

    2005-02-25

    Ions were detected in the vicinity of Saturn's A ring by the Ion and Neutral Mass Spectrometer (INMS) instrument onboard the Cassini Orbiter during the spacecraft's passage over the rings. The INMS saw signatures of molecular and atomic oxygen ions and of protons, thus demonstrating the existence of an ionosphere associated with the A ring. A likely explanation for these ions is photoionization by solar ultraviolet radiation of neutral O2 molecules associated with a tenuous ring atmosphere. INMS neutral measurements made during the ring encounter are dominated by a background signal.

  5. Heavy Ion Fusion Accelerator Research (HIFAR)

    Energy Technology Data Exchange (ETDEWEB)

    1991-04-01

    This report discusses the following topics: emittance variations in current-amplifying ion induction lina; transverse emittance studies of an induction accelerator of heavy ions; drift compression experiments on MBE-4 and related emittance; low emittance uniform- density C{sub s}+ sources for heavy ion fusion accelerator studies; survey of alignment of MBE-4; time-of-flight dependence on the MBE-4 quadrupole voltage; high order calculation of the multiple content of three dimensional electrostatic geometries; an induction linac injector for scaled experiments; induction accelerator test module for HIF; longitudinal instability in HIF beams; and analysis of resonant longitudinal instability in a heavy ion induction linac.

  6. 11. international conference on ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, D.; Lyneis, C.; Cheng, D.; Galloway, M.L.; Leitner, M.; Todd, D.S.; Ciavola, G.; Gammino, S.; Celona, L.; Ando, L.; Torrisi, L.; Cavenago, M.; Galata, A.; Spaedtke, P.; Tinschert, K.; Lang, R.; Iannucci, R.; Leroy, R.; Barue, C.; Hitz, D.; Koivisto, H.; Suominen, P.; Tarvainen, O.; Beijers, H.; Brandenburg, S.; Vanrooyen, D.; Hillo, C.; Kuchler, D.; Homeyer, H.; Rohrich, J.; Schachter, L.; Dobrescu, S.; Nakagawa, T.; Higurashi, Y.; Kidera, M.; Aihara, T.; Kase, M.; Goto, A.; Yang, Y.; Zhao, H.W.; Zhang, Z.M.; Zhang, X.Z.; Guo, X.H.; He, W.E.; Sun, L.T.; Yuan, P.; Song, M.T.; Xie, Z.Q.; Cao, Y.; Zhan, W.L.; Wei, B.W.; Bricault, P.; Lau, C.; Essabaa, S.; Cheikh Mhamed, M.; Bajeat, O.; Ducourtieux, M.; Lefort, H.; Panteleev, V.N.; Barzakh, A.E.; Fedorov, D.V.; Ionan, A.M.; Mezilev, K.A.; Moroz, F.V.; Orlov, S.Y.; Volkov, Y.M.; Andrighetto, A.; Lhersonneau, G.; Rizzi, V.; Tecchio, L.B.; Dubois, M.; Gaubert, G.; Jardins, P.; Lecesne, N.; Leroy, R.; Pacquet, J.Y.; Saint Laurent, M.G.; Villari, A.C.O.; Bajeat, O.; Essabaa, S.; Lau, C.; Menna, M.; Franberg, H.; Ammann, M.; Gdggeler, H.W.; Koster, U.; Allen, F.; Biedermann, C.; Radtke, R.; Ames, F.; Baartman, R.; Bricault, P.; Jayamanna, K.; Lamy, T.; McDonald, M.; Olivo, M.; Schmorl, P.; Yuan, D.H.L.; Asaji, T.; Sasaki, H.; Kato, Y.; Atabaev, B.; Radjabov, S.S.; Akhmadjanova, M.K.; Yuzikaeva, F.R.; Baoqun, Cui; Liqiang, Li; Yingjun, Ma; Shengyun, Zhu; Cong, Jiang

    2005-07-01

    This document gathers the summaries of the presentations made at ICIS05 (international conference on ion sources). It can be organized into 3 main topics: 1) 'fundamentals and theory' that deals with plasma, beam extraction, transport and emittance, diagnostics and simulation; 2) 'various types of ion sources' that include ECRIS, EBIS, microwave, negative, radioactive, polarized and laser ion sources, and charge breeders; and 3) 'ion sources and applications' in fields like accelerator injection, fusion energy, space propulsion, mass spectrometry, and neutron and cluster and rare nuclide production.

  7. Potential biomedical applications of ion beam technology

    Science.gov (United States)

    Banks, B. A.; Weigand, A. J.; Van Kampen, C. L.; Babbush, C. A.

    1976-01-01

    Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic prosthesis fixation, and dental implants.

  8. Paper-based potentiometric ion sensing.

    Science.gov (United States)

    Lan, Wen-Jie; Zou, Xu U; Hamedi, Mahiar M; Hu, Jinbo; Parolo, Claudio; Maxwell, E Jane; Bühlmann, Philippe; Whitesides, George M

    2014-10-07

    This paper describes the design and fabrication of ion-sensing electrochemical paper-based analytical devices (EPADs) in which a miniaturized paper reference electrode is integrated with a small ion-selective paper electrode (ISPE) for potentiometric measurements. Ion-sensing EPADs use printed wax barriers to define electrochemical sample and reference zones. Single-layer EPADs for sensing of chloride ions include wax-defined sample and reference zones that each incorporate a Ag/AgCl electrode. In EPADs developed for other electrolytes (potassium, sodium, and calcium ions), a PVC-based ion-selective membrane is added to separate the sample zone from a paper indicator electrode. After the addition of a small volume (less than 10 μL) of sample and reference solutions to different zones, ion-sensing EPADs exhibit a linear response, over 3 orders of magnitude, in ranges of electrolyte concentrations that are relevant to a variety of applications, with a slope close to the theoretical value (59.2/z mV). Ion-selective EPADs provide a portable, inexpensive, and disposable way of measuring concentrations of electrolyte ions in aqueous solutions.

  9. Spectroscopy of mobility-selected biomolecular ions.

    Science.gov (United States)

    Papadopoulos, Georgios; Svendsen, Annette; Boyarkin, Oleg V; Rizzo, Thomas R

    2011-01-01

    We describe here experiments that combine differential ion mobility, which separates conformational isomers of biomolecular ions, with electronic spectroscopy in a cold, radio-frequency ion trap. Although the low temperature attainable in a cold ion trap greatly simplifies the electronic spectra of large molecules, conformational heterogeneity can still be a significant source of congestion, complicating spectroscopic analysis. We demonstrate here that using differential ion mobility to separate gas-phase peptide conformers before injecting them into a cold ion trap allows one to decompose a dense spectrum into contributions from different conformational families. In the inverse sense, cold ion spectroscopy can be used as a conformation-specific detector for ion mobility, allowing one to separate an unresolved peak into contributions from different conformational families. The doubly protonated peptide bradykinin serves as a good test case for the marriage of these two techniques as it exhibits a considerable degree of conformational heterogeneity that results in a highly congested electronic spectrum. Our results demonstrate the feasibility and advantages of directly coupling ion mobility with spectroscopy and provide a diagnostic of conformational isomerization of this peptide after being produced in the gas phase by electrospray.

  10. Neutral beamline with improved ion energy recovery

    Science.gov (United States)

    Dagenhart, William K.; Haselton, Halsey H.; Stirling, William L.; Whealton, John H.

    1984-01-01

    A neutral beamline generator with unneutralized ion energy recovery is provided which enhances the energy recovery of the full energy ion component of the beam exiting the neutralizer cell of the beamline. The unneutralized full energy ions exiting the neutralizer are deflected from the beam path and the electrons in the cell are blocked by a magnetic field applied transverse to the beamline in the cell exit region. The ions, which are generated at essentially ground potential and accelerated through the neutralizer cell by a negative acceleration voltage, are collected at ground potential. A neutralizer cell exit end region is provided which allows the magnetic and electric fields acting on the exiting ions to be closely coupled. As a result, the fractional energy ions exiting the cell with the full energy ions are reflected back into the gas cell. Thus, the fractional energy ions do not detract from the energy recovery efficiency of full energy ions exiting the cell which can reach the ground potential interior surfaces of the beamline housing.

  11. Ion Sources for MedAustron

    CERN Document Server

    Lettry, J; Wallner, J; Sargsyan, E; CERN. Geneva. BE Department

    2010-01-01

    The MedAustron Ion therapy center will be constructed in Wiener Neustadt (Austria) in the vicinity of Vienna. Its accelerator complex consists of four ion sources, a linear accelerator, a synchrotron and a beam delivery system to the three medical treatment rooms and to the research irradiation room. The ion sources shall deliver beams of H31+, C4+ and light ions with utmost reliability and stability. This paper describes the features of the ion sources presently planned for the MedAustron facility; such as ion source main parameters, gas injection, temperature control and cooling systems. A dedicated beam diagnostics technique is proposed in order to characterize ECR ions beams; in the first drift region after the ion source, a fraction of the mixed beam is selected via moveable aperture. With standard beam diagnostics, we then aim to produce position-dependant observables such as ion-current density, beam energy distribution and emittance for each charge states to be compared to simulations of ECR e-heating...

  12. Lithium-ion batteries fundamentals and applications

    CERN Document Server

    Wu, Yuping

    2015-01-01

    Lithium-Ion Batteries: Fundamentals and Applications offers a comprehensive treatment of the principles, background, design, production, and use of lithium-ion batteries. Based on a solid foundation of long-term research work, this authoritative monograph:Introduces the underlying theory and history of lithium-ion batteriesDescribes the key components of lithium-ion batteries, including negative and positive electrode materials, electrolytes, and separatorsDiscusses electronic conductive agents, binders, solvents for slurry preparation, positive thermal coefficient (PTC) materials, current col

  13. Ion thruster charge-exchange plasma flow

    Science.gov (United States)

    Carruth, M. R., Jr.; Gabriel, S. B.; Kitamura, S.

    1982-01-01

    The electron bombardment ion thruster has been under development for a number of years and during this time, studies of the plasmas produced by the thrusters and their interactions with spacecraft have been evaluated, based on available data. Due to diagnostic techniques used and facility effects, there is uncertainty as to the reliability of data from these early studies. This paper presents data on the flow of the charge-exchange plasma produced just downstream of the thruster's ion optics. The 'end-effect' of a cylindrical Langmuir probe is used to determine ion density and directed ion velocity. Results are compared with data obtained from a retarding potential analyzer-Faraday cup.

  14. Plasma immersion ion implantation for reducing metal ion release

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, C.; Garcia, J. A.; Maendl, S.; Pereiro, R.; Fernandez, B.; Rodriguez, R. J. [Centro de Ingenieria Avanzada de Superficies AIN, 31191, Cordovilla-Pamplona (Spain); Leibniz-Institut fuer Oberflaechenmodifizierung, 04318 Leipzig (Germany); Universidad de Oviedo, Departamento Quimica Fisica y Analitica (Spain); Centro de Ingenieria Avanzada de Superficies AIN, 31191, Cordovilla-Pamplona (Spain)

    2012-11-06

    Plasma immersion ion implantation of Nitrogen and Oxygen on CoCrMo alloys was carried out to improve the tribological and corrosion behaviors of these biomedical alloys. In order to optimize the implantation results we were carried experiments at different temperatures. Tribocorrosion tests in bovine serum were used to measure Co, Cr and Mo releasing by using Inductively Coupled Plasma Mass Spectrometry analysis after tests. Also, X-ray Diffraction analysis were employed in order to explain any obtained difference in wear rate and corrosion tests. Wear tests reveals important decreases in rate of more than one order of magnitude for the best treatment. Moreover decreases in metal release were found for all the implanted samples, preserving the same corrosion resistance of the unimplanted samples. Finally this paper gathers an analysis, in terms of implantation parameters and achieved properties for industrial implementation of these treatments.

  15. An ion guide laser ion source for isobar-suppressed rare isotope beams

    Energy Technology Data Exchange (ETDEWEB)

    Raeder, Sebastian, E-mail: sebastian.raeder@fys.kuleuven.be; Ames, Friedhelm; Bishop, Daryl; Bricault, Pierre; Kunz, Peter; Mjøs, Anders [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Heggen, Henning, E-mail: heggen@triumf.ca [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Institute of Applied Physics, TU Darmstadt, Schlossgartenstr. 7, 64289 Darmstadt (Germany); Lassen, Jens, E-mail: lassen@triumf.ca; Teigelhöfer, Andrea [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada)

    2014-03-15

    Modern experiments at isotope separator on-line (ISOL) facilities like ISAC at TRIUMF often depend critically on the purity of the delivered rare isotope beams. Therefore, highly selective ion sources are essential. This article presents the development and successful on-line operation of an ion guide laser ion source (IG-LIS) for the production of ion beams free of isobaric contamination. Thermionic ions from the hot ISOL target are suppressed by an electrostatic potential barrier, while neutral radio nuclides effusing out are resonantly ionized by laser radiation within a quadrupole ion guide behind this barrier. The IG-LIS was developed through detailed thermal and ion optics simulation studies and off-line tests with stable isotopes. In a first on-line run with a SiC target a suppression of surface-ionized Na contaminants in the ion beam of up to six orders of magnitude was demonstrated.

  16. Ion hole formation and nonlinear generation of electromagnetic ion cyclotron waves: THEMIS observations

    Science.gov (United States)

    Shoji, Masafumi; Miyoshi, Yoshizumi; Katoh, Yuto; Keika, Kunihiro; Angelopoulos, Vassilis; Kasahara, Satoshi; Asamura, Kazushi; Nakamura, Satoko; Omura, Yoshiharu

    2017-09-01

    Electromagnetic plasma waves are thought to be responsible for energy exchange between charged particles in space plasmas. Such an energy exchange process is evidenced by phase space holes identified in the ion distribution function and measurements of the dot product of the plasma wave electric field and the ion velocity. We develop a method to identify ion hole formation, taking into consideration the phase differences between the gyromotion of ions and the electromagnetic ion cyclotron (EMIC) waves. Using this method, we identify ion holes in the distribution function and the resulting nonlinear EMIC wave evolution from Time History of Events and Macroscale Interactions during Substorms (THEMIS) observations. These ion holes are key to wave growth and frequency drift by the ion currents through nonlinear wave-particle interactions, which are identified by a computer simulation in this study.

  17. Motion of negative ion plasma near the boundary with electron−ion plasma

    Energy Technology Data Exchange (ETDEWEB)

    Medvedev, Yu. V., E-mail: medve@mail.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2017-01-15

    Processes occurring near the boundary between three-component plasma with negative ions and two-component electron−ion plasma are considered. The excited waves and instability are described. Stability condition at the boundary is determined.

  18. Production of High Energy Ions Near an Ion Thruster Discharge Hollow Cathode

    Science.gov (United States)

    Katz, Ira; Mikellides, I. G.; Goebel, D. M.; Jameson, K. K.; Wirz, R.; Polk, James E.

    2006-01-01

    Several researchers have measured ions leaving ion thruster discharge chambers with energies far greater than measured discharge chamber potentials. Presented in this paper is a new mechanism for the generation of high energy ions and a comparison with measured ion spectra. The source of high energy ions has been a puzzle because they not only have energies in excess of measured steady state potentials, but as reported by Goebel et. al. [1], their flux is independent of the amplitude of time dependent plasma fluctuations. The mechanism relies on the charge exchange neutralization of xenon ions accelerated radially into the potential trough in front of the discharge cathode. Previous researchers [2] have identified the importance of charge exchange in this region as a mechanism for protecting discharge cathode surfaces from ion bombardment. This paper is the first to identify how charge exchange in this region can lead to ion energy enhancement.

  19. Hybrid Lithium-ion Capacitor / Lithium-ion Battery System for Extended Performance Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The work focused on testing the Li-ion supercapacitors to confirm their performance and safety.  The li-ion supercaps were found to be safe under several...

  20. Simulation of Electric Potentials and Ion Motion in Planar Electrode Structures for Lossless Ion Manipulations (SLIM)

    OpenAIRE

    Garimella, Sandilya V.B.; Ibrahim, Yehia M.; Webb, Ian K.; Tolmachev, Aleksey V.; Zhang, Xinyu; Prost, Spencer A; Anderson, Gordon A.; Smith, Richard D.

    2014-01-01

    We report a conceptual study and computational evaluation of novel planar electrode Structures for Lossless Ion Manipulations (SLIM). Planar electrode SLIM devices were designed that allow for flexible ion confinement, transport and storage using a combination of RF and DC fields. Effective potentials can be generated that provide near ideal regions for confining and manipulating ions in the presence of a gas. Ion trajectory simulations using SIMION 8.1 demonstrated the capability for lossles...