WorldWideScience

Sample records for texture progressive analysis

  1. 3D texture analysis reveals imperceptible MRI textural alterations in the thalamus and putamen in progressive myoclonic epilepsy type 1, EPM1.

    Directory of Open Access Journals (Sweden)

    Sanna Suoranta

    Full Text Available Progressive myoclonic epilepsy type 1 (EPM1 is an autosomal recessively inherited neurodegenerative disorder characterized by young onset age, myoclonus and tonic-clonic epileptic seizures. At the time of diagnosis, the visual assessment of the brain MRI is usually normal, with no major changes found later. Therefore, we utilized texture analysis (TA to characterize and classify the underlying properties of the affected brain tissue by means of 3D texture features. Sixteen genetically verified patients with EPM1 and 16 healthy controls were included in the study. TA was performed upon 3D volumes of interest that were placed bilaterally in the thalamus, amygdala, hippocampus, caudate nucleus and putamen. Compared to the healthy controls, EPM1 patients had significant textural differences especially in the thalamus and right putamen. The most significantly differing texture features included parameters that measure the complexity and heterogeneity of the tissue, such as the co-occurrence matrix-based entropy and angular second moment, and also the run-length matrix-based parameters of gray-level non-uniformity, short run emphasis and long run emphasis. This study demonstrates the usability of 3D TA for extracting additional information from MR images. Textural alterations which suggest complex, coarse and heterogeneous appearance were found bilaterally in the thalamus, supporting the previous literature on thalamic pathology in EPM1. The observed putamenal involvement is a novel finding. Our results encourage further studies on the clinical applications, feasibility, reproducibility and reliability of 3D TA.

  2. Texture analysis of

    NARCIS (Netherlands)

    Lubsch, A.; Timmermans, K.

    2017-01-01

    Texture analysis is a method to test the physical properties of a material by tension and compression. The growing interest in commercialisation of seaweeds for human food has stimulated research into the physical properties of seaweed tissue. These are important parameters for the survival of

  3. Parallel-Sequential Texture Analysis

    NARCIS (Netherlands)

    van den Broek, Egon; Singh, Sameer; Singh, Maneesha; van Rikxoort, Eva M.; Apte, Chid; Perner, Petra

    2005-01-01

    Color induced texture analysis is explored, using two texture analysis techniques: the co-occurrence matrix and the color correlogram as well as color histograms. Several quantization schemes for six color spaces and the human-based 11 color quantization scheme have been applied. The VisTex texture

  4. Texture analysis using Gabor wavelets

    Science.gov (United States)

    Naghdy, Golshah A.; Wang, Jian; Ogunbona, Philip O.

    1996-04-01

    Receptive field profiles of simple cells in the visual cortex have been shown to resemble even- symmetric or odd-symmetric Gabor filters. Computational models employed in the analysis of textures have been motivated by two-dimensional Gabor functions arranged in a multi-channel architecture. More recently wavelets have emerged as a powerful tool for non-stationary signal analysis capable of encoding scale-space information efficiently. A multi-resolution implementation in the form of a dyadic decomposition of the signal of interest has been popularized by many researchers. In this paper, Gabor wavelet configured in a 'rosette' fashion is used as a multi-channel filter-bank feature extractor for texture classification. The 'rosette' spans 360 degrees of orientation and covers frequencies from dc. In the proposed algorithm, the texture images are decomposed by the Gabor wavelet configuration and the feature vectors corresponding to the mean of the outputs of the multi-channel filters extracted. A minimum distance classifier is used in the classification procedure. As a comparison the Gabor filter has been used to classify the same texture images from the Brodatz album and the results indicate the superior discriminatory characteristics of the Gabor wavelet. With the test images used it can be concluded that the Gabor wavelet model is a better approximation of the cortical cell receptive field profiles.

  5. Texture analysis using Renyi's generalized entropies

    NARCIS (Netherlands)

    Grigorescu, SE; Petkov, N

    2003-01-01

    We propose a texture analysis method based on Renyi's generalized entropies. The method aims at identifying texels in regular textures by searching for the smallest window through which the minimum number of different visual patterns is observed when moving the window over a given texture. The

  6. Evaluation of color representation for texture analysis

    NARCIS (Netherlands)

    Verbrugge, R.; van den Broek, Egon; van Rikxoort, E.M.; Taatgen, N.; Schomaker, L.

    2004-01-01

    Since more than 50 years texture in image material is a topic of research. Hereby, color was ignored mostly. This study compares 70 different configurations for texture analysis, using four features. For the configurations we used: (i) a gray value texture descriptor: the co-occurrence matrix and a

  7. Description of textures by a structural analysis.

    Science.gov (United States)

    Tomita, F; Shirai, Y; Tsuji, S

    1982-02-01

    A structural analysis system for describing natural textures is introduced. The analyzer automatically extracts the texture elements in an input image, measures their properties, classifies them into some distinctive classes (one ``ground'' class and some ``figure'' classes), and computes the distributions of the gray level, the shape, and the placement of the texture elements in each class. These descriptions are used for classification of texture images. An analysis-by-synthesis method for evaluating texture analyzers is also presented. We propose a synthesizer which generates a texture image based on the descriptions. By comparing the reconstructed image with the original one, we can see what information is preserved and what is lost in the descriptions.

  8. TEXTURE ANALYSIS OF SPELT WHEAT BREAD

    Directory of Open Access Journals (Sweden)

    Magdaléna Lacko - Bartošová

    2013-02-01

    Full Text Available The bread quality is considerably dependent on the texture characteristic of bread crumb. Texture analysis is primarily concerned with the evaluation of mechanical characteristics where a material is subjected to a controlled force from which a deformation curve of its response is generated. It is an objective physical examination of baked products and gives direct information on the product quality, oppositely to dough rheology tests what are inform on the baking suitability of the flour, as raw material. This is why the texture analysis is one of the most helpful analytical methods of the product development. In the framework of our research during the years 2008 – 2009 were analyzed selected indicators of bread crumb for texture quality of three Triticum spelta L. cultivars – Oberkulmer Rotkorn, Rubiota and Franckenkorn grown in an ecological system at the locality of Dolna Malanta near Nitra. The bread texture quality was evaluated on texture analyzer TA.XT Plus and expressed as crumb firmness (N, stiffness (N.mm-1 and relative elasticity (%.Our research proved that all selected indicators were significantly influenced by the year of growing and variety. The most soft bread was measured in Rubiota, whereas bread crumb samples from Franckenkorn were the most firm and stiff. Relative elasticity confirmed that the lowest firmness and stiffness was found in Rubiota bread. The spelt grain can be a good source for making bread flour, but is closely dependent on choice of spelt variety.

  9. Neutronographic Texture Analysis of Zirconium Based Alloys

    International Nuclear Information System (INIS)

    Kruz'elová, M; Vratislav, S; Kalvoda, L; Dlouhá, M

    2012-01-01

    Neutron diffraction is a very powerful tool in texture analysis of zirconium based alloys used in nuclear technique. Textures of five samples (two rolled sheets and three tubes) were investigated by using basal pole figures, inversion pole figures, and ODF distribution function. The texture measurement was performed at diffractometer KSN2 on the Laboratory of Neutron Diffraction, Department of Solid State Engineering, Faculty of Nuclear Sciences and Physical Engineering, CTU in Prague. Procedures for studying textures with thermal neutrons and procedures for obtaining texture parameters (direct and inverse pole figures, three dimensional orientation distribution function) are also described. Observed data were processed by software packages HEXAL and GSAS. Our results can be summarized as follows: i) All samples of zirconium alloys show the distribution of middle area into two maxima in basal pole figures. This is caused by alloying elements. A characteristic split of the basal pole maxima tilted from the normal direction toward the transverse direction can be observed for all samples, ii) Sheet samples prefer orientation of planes (100) and (110) perpendicular to rolling direction and orientation of planes (002) perpendicular to normal direction, iii) Basal planes of tubes are oriented parallel to tube axis, meanwhile (100) planes are oriented perpendicular to tube axis. Level of resulting texture and maxima position is different for tubes and for sheets. The obtained results are characteristic for zirconium based alloys.

  10. SURFACE TEXTURE ANALYSIS FOR FUNCTIONALITY CONTROL

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Andreasen, Jan Lasson; Tosello, Guido

    This document is used in connection with three exercises of 3 hours duration as a part of the course VISION ONLINE – One week course on Precision & Nanometrology. The exercises concern surface texture analysis for functionality control, in connection with three different case stories. This docume...... contains a short description of each case story, 3-D roughness parameters analysis and relation with the product’s functionality.......This document is used in connection with three exercises of 3 hours duration as a part of the course VISION ONLINE – One week course on Precision & Nanometrology. The exercises concern surface texture analysis for functionality control, in connection with three different case stories. This document...

  11. Texture-based analysis of COPD

    DEFF Research Database (Denmark)

    Sørensen, Lauge; Nielsen, Mads; Lo, Pechin Chien Pau

    2012-01-01

    This study presents a fully automatic, data-driven approach for texture-based quantitative analysis of chronic obstructive pulmonary disease (COPD) in pulmonary computed tomography (CT) images. The approach uses supervised learning where the class labels are, in contrast to previous work, based...... on measured lung function instead of on manually annotated regions of interest (ROIs). A quantitative measure of COPD is obtained by fusing COPD probabilities computed in ROIs within the lung fields where the individual ROI probabilities are computed using a k nearest neighbor (kNN ) classifier. The distance...... and subsequently applied to classify 200 independent images from the same screening trial. The texture-based measure was significantly better at discriminating between subjects with and without COPD than were the two most common quantitative measures of COPD in the literature, which are based on density...

  12. Texture Analysis Using Rényi’s Generalized Entropies

    NARCIS (Netherlands)

    Grigorescu, S.E.; Petkov, N.

    2003-01-01

    We propose a texture analysis method based on Rényi’s generalized entropies. The method aims at identifying texels in regular textures by searching for the smallest window through which the minimum number of different visual patterns is observed when moving the window over a given texture. The

  13. Quantitative texture analysis of electrodeposited line patterns

    DEFF Research Database (Denmark)

    Pantleon, Karen; Somers, Marcel A.J.

    2005-01-01

    Free-standing line patterns of Cu and Ni were manufactured by electrochemical deposition into lithographically prepared patterns. Electrodeposition was carried out on top of a highly oriented Au-layer physically vapor deposited on glass. Quantitative texture analysis carried out by means of x......-ray diffraction for both the substrate layer and the electrodeposits yielded experimental evidence for epitaxy between Cu and Au. An orientation relation between film and substrate was discussed with respect to various concepts of epitaxy. While the conventional mode of epitaxy fails for the Cu...

  14. Progress in melt-texturing of YBCO superconductors

    International Nuclear Information System (INIS)

    Salama, K.; Lee, D.F.; Selvamanickam, V.

    1993-01-01

    Since the discovery of high temperature superconductors (HTS), tremendous efforts have been expanded toward the improvement of these materials. Due to the weak-link problem associated with grain boundaries, sintered bulk HTS possess a transport critical current density (J c ) on the order of 10 2 -10 3 A/cm 2 at 77 K. While these sintered superconductors may be utilized in low current applications, novel processing methods have to be developed to obtain HTS that can sustain high currents. Melt-texturing of HTS was found to result in a high degree of grain orientation, and is presently the most prominent processing method used to manufacture bulk YBa 2 Cu 3 O x (123) with superior transport and magnetic properties. In this review paper, various melt-texturing methods will be discussed, and the variation in J c with processing will be presented. (orig.)

  15. Textural features for radar image analysis

    Science.gov (United States)

    Shanmugan, K. S.; Narayanan, V.; Frost, V. S.; Stiles, J. A.; Holtzman, J. C.

    1981-01-01

    Texture is seen as an important spatial feature useful for identifying objects or regions of interest in an image. While textural features have been widely used in analyzing a variety of photographic images, they have not been used in processing radar images. A procedure for extracting a set of textural features for characterizing small areas in radar images is presented, and it is shown that these features can be used in classifying segments of radar images corresponding to different geological formations.

  16. On Texture and Geometry in Image Analysis

    DEFF Research Database (Denmark)

    Gustafsson, David Karl John

    2009-01-01

    fields and Maximum Entropy (FRAME) model [213, 214] is used for inpaining texture. We argue that many ’textures’ contain details that must be inpainted exactly. Simultaneous reconstruction of geometric structure and texture is a difficult problem, therefore, a two-phase reconstruction procedure...... is proposed. An inverse temperature is added to the FRAME model. In the first phase, the geometric structure is reconstructed by cooling the distribution, and in the second phase, the texture is added by heating the distribution. Empirically, we show that the long range geometric structure is inpainted...

  17. Prediction of progression of radiographic knee osteoarthritis using tibial trabecular bone texture

    DEFF Research Database (Denmark)

    Woloszynski, T; Podsiadlo, P; Stachowiak, G W

    2012-01-01

    OBJECTIVE.: To develop a system for prediction of progression of radiographic knee osteoarthritis (OA) using tibial trabecular bone (TB) texture. METHODS.: We studied 203 knees with (n=68) or without (n=135) radiographic tibiofemoral OA in 105 subjects (90 men, 15 women, mean age 54 years) who ha...

  18. Multi Texture Analysis of Colorectal Cancer Continuum Using Multispectral Imagery.

    Directory of Open Access Journals (Sweden)

    Ahmad Chaddad

    Full Text Available This paper proposes to characterize the continuum of colorectal cancer (CRC using multiple texture features extracted from multispectral optical microscopy images. Three types of pathological tissues (PT are considered: benign hyperplasia, intraepithelial neoplasia and carcinoma.In the proposed approach, the region of interest containing PT is first extracted from multispectral images using active contour segmentation. This region is then encoded using texture features based on the Laplacian-of-Gaussian (LoG filter, discrete wavelets (DW and gray level co-occurrence matrices (GLCM. To assess the significance of textural differences between PT types, a statistical analysis based on the Kruskal-Wallis test is performed. The usefulness of texture features is then evaluated quantitatively in terms of their ability to predict PT types using various classifier models.Preliminary results show significant texture differences between PT types, for all texture features (p-value < 0.01. Individually, GLCM texture features outperform LoG and DW features in terms of PT type prediction. However, a higher performance can be achieved by combining all texture features, resulting in a mean classification accuracy of 98.92%, sensitivity of 98.12%, and specificity of 99.67%.These results demonstrate the efficiency and effectiveness of combining multiple texture features for characterizing the continuum of CRC and discriminating between pathological tissues in multispectral images.

  19. Research of second harmonic generation images based on texture analysis

    Science.gov (United States)

    Liu, Yao; Li, Yan; Gong, Haiming; Zhu, Xiaoqin; Huang, Zufang; Chen, Guannan

    2014-09-01

    Texture analysis plays a crucial role in identifying objects or regions of interest in an image. It has been applied to a variety of medical image processing, ranging from the detection of disease and the segmentation of specific anatomical structures, to differentiation between healthy and pathological tissues. Second harmonic generation (SHG) microscopy as a potential noninvasive tool for imaging biological tissues has been widely used in medicine, with reduced phototoxicity and photobleaching. In this paper, we clarified the principles of texture analysis including statistical, transform, structural and model-based methods and gave examples of its applications, reviewing studies of the technique. Moreover, we tried to apply texture analysis to the SHG images for the differentiation of human skin scar tissues. Texture analysis method based on local binary pattern (LBP) and wavelet transform was used to extract texture features of SHG images from collagen in normal and abnormal scars, and then the scar SHG images were classified into normal or abnormal ones. Compared with other texture analysis methods with respect to the receiver operating characteristic analysis, LBP combined with wavelet transform was demonstrated to achieve higher accuracy. It can provide a new way for clinical diagnosis of scar types. At last, future development of texture analysis in SHG images were discussed.

  20. Textural Maturity Analysis and Sedimentary Environment Discrimination Based on Grain Shape Data

    Science.gov (United States)

    Tunwal, M.; Mulchrone, K. F.; Meere, P. A.

    2017-12-01

    Morphological analysis of clastic sedimentary grains is an important source of information regarding the processes involved in their formation, transportation and deposition. However, a standardised approach for quantitative grain shape analysis is generally lacking. In this contribution we report on a study where fully automated image analysis techniques were applied to loose sediment samples collected from glacial, aeolian, beach and fluvial environments. A range of shape parameters are evaluated for their usefulness in textural characterisation of populations of grains. The utility of grain shape data in ranking textural maturity of samples within a given sedimentary environment is evaluated. Furthermore, discrimination of sedimentary environment on the basis of grain shape information is explored. The data gathered demonstrates a clear progression in textural maturity in terms of roundness, angularity, irregularity, fractal dimension, convexity, solidity and rectangularity. Textural maturity can be readily categorised using automated grain shape parameter analysis. However, absolute discrimination between different depositional environments on the basis of shape parameters alone is less certain. For example, the aeolian environment is quite distinct whereas fluvial, glacial and beach samples are inherently variable and tend to overlap each other in terms of textural maturity. This is most likely due to a collection of similar processes and sources operating within these environments. This study strongly demonstrates the merit of quantitative population-based shape parameter analysis of texture and indicates that it can play a key role in characterising both loose and consolidated sediments. This project is funded by the Irish Petroleum Infrastructure Programme (www.pip.ie)

  1. Second order statistical analysis of US image texture

    International Nuclear Information System (INIS)

    Tanzi, F.; Novario, R.

    1999-01-01

    The study reports the sonographic image texture of the neonatal heart in different stages of development by calculating numerical parameters extracted from the gray scale co-occurrence matrix. To show pixel values differences and enhance texture structure, images were equalized and then the gray level range was reduced to 16 to allow sufficiently high occupancy frequency of the co-occurrence matrix. Differences are so little significant that they may be due to different factors affecting image texture and the variability introduced by manual ROI positioning; therefore no definitive conclusions can be drawn as to considering this kind of analysis capable of discriminating different stages of myocardial development [it

  2. The promise and limits of PET texture analysis.

    Science.gov (United States)

    Cheng, Nai-Ming; Fang, Yu-Hua Dean; Yen, Tzu-Chen

    2013-11-01

    Metabolic heterogeneity is a recognized characteristic of malignant tumors. Positron emission tomography (PET) texture analysis evaluated intratumoral heterogeneity in the uptake of (18)F-fluorodeoxyglucose. There were recent evidences that PET textural features were of prognostic significance in patients with different solid tumors. Unfortunately, there are still crucial standardization challenges to transform PET texture parameters from their current use as research tools into the arena of validated technologies for use in oncology practice. Testing its generalizability, robustness, consistency, and limitations is necessary before implementing it in daily patient care.

  3. Monitoring Progression of Amyotrophic Lateral Sclerosis Using Ultrasound Morpho-Textural Muscle Biomarkers: A Pilot Study.

    Science.gov (United States)

    Martínez-Payá, Jacinto J; Ríos-Díaz, José; Medina-Mirapeix, Francesc; Vázquez-Costa, Juan F; Del Baño-Aledo, María Elena

    2018-01-01

    The need is increasing for progression biomarkers that allow the loss of motor neurons in amyotrophic lateral sclerosis (ALS) to be monitored in clinical trials. In this prospective longitudinal study, muscle thickness, echointensity, echovariation and gray level co-occurrence matrix textural features are examined as possible progression ultrasound biomarkers in ALS patients during a 5-mo follow-up period. We subjected 13 patients to 3 measurements for 20 wk. They showed a significant loss of muscle, an evident tendency to loss of thickness and increased echointensity and echovariation. In regard to textural parameters, muscle heterogeneity tended to increase as a result of the neoformation of non-contractile tissue through denervation. Considering some limitations of the study, the quantitative muscle ultrasound biomarkers evaluated showed a promising ability to monitor patients affected by ALS. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  4. Texture analysis of Napoleonic War Era copper bolts

    Science.gov (United States)

    Malamud, Florencia; Northover, Shirley; James, Jon; Northover, Peter; Kelleher, Joe

    2016-04-01

    Neutron diffraction techniques are suitable for volume texture analyses due to high penetration of thermal neutrons in most materials. We have implemented a new data analysis methodology that employed the spatial resolution achievable by a time-of-flight neutron strain scanner to non-destructively determine the crystallographic texture at selected locations within a macroscopic sample. The method is based on defining the orientation distribution function of the crystallites from several incomplete pole figures, and it has been implemented on ENGIN-X, a neutron strain scanner at the Isis Facility in the UK. Here, we demonstrate the application of this new texture analysis methodology in determining the crystallographic texture at selected locations within museum quality archaeological objects up to 1 m in length. The results were verified using samples of similar, but less valuable, objects by comparing the results of applying this method with those obtained using both electron backscatter diffraction and X-ray diffraction on their cross sections.

  5. "Textural analysis of multiparametric MRI detects transition zone prostate cancer".

    Science.gov (United States)

    Sidhu, Harbir S; Benigno, Salvatore; Ganeshan, Balaji; Dikaios, Nikos; Johnston, Edward W; Allen, Clare; Kirkham, Alex; Groves, Ashley M; Ahmed, Hashim U; Emberton, Mark; Taylor, Stuart A; Halligan, Steve; Punwani, Shonit

    2017-06-01

    To evaluate multiparametric-MRI (mpMRI) derived histogram textural-analysis parameters for detection of transition zone (TZ) prostatic tumour. Sixty-seven consecutive men with suspected prostate cancer underwent 1.5T mpMRI prior to template-mapping-biopsy (TPM). Twenty-six men had 'significant' TZ tumour. Two radiologists in consensus matched TPM to the single axial slice best depicting tumour, or largest TZ diameter for those with benign histology, to define single-slice whole TZ-regions-of-interest (ROIs). Textural-parameter differences between single-slice whole TZ-ROI containing significant tumour versus benign/insignificant tumour were analysed using Mann Whitney U test. Diagnostic accuracy was assessed by receiver operating characteristic area under curve (ROC-AUC) analysis cross-validated with leave-one-out (LOO) analysis. ADC kurtosis was significantly lower (p Textural features of the whole prostate TZ can discriminate significant prostatic cancer through reduced kurtosis of the ADC-histogram where significant tumour is included in TZ-ROI and reduced T1 entropy independent of tumour inclusion. • MR textural features of prostate transition zone may discriminate significant prostatic cancer. • Transition zone (TZ) containing significant tumour demonstrates a less peaked ADC histogram. • TZ containing significant tumour reveals higher post-contrast T1-weighted homogeneity. • The utility of MR texture analysis in prostate cancer merits further investigation.

  6. Textural Analysis of Fatique Crack Surfaces: Image Pre-processing

    Directory of Open Access Journals (Sweden)

    H. Lauschmann

    2000-01-01

    Full Text Available For the fatique crack history reconstitution, new methods of quantitative microfractography are beeing developed based on the image processing and textural analysis. SEM magnifications between micro- and macrofractography are used. Two image pre-processing operatins were suggested and proved to prepare the crack surface images for analytical treatment: 1. Normalization is used to transform the image to a stationary form. Compared to the generally used equalization, it conserves the shape of brightness distribution and saves the character of the texture. 2. Binarization is used to transform the grayscale image to a system of thick fibres. An objective criterion for the threshold brightness value was found as that resulting into the maximum number of objects. Both methods were succesfully applied together with the following textural analysis.

  7. Aesthetic Perception of Visual Textures: A Holistic Exploration using Texture Analysis, Psychological Experiment and Perception Modeling

    Directory of Open Access Journals (Sweden)

    Jianli eLiu

    2015-11-01

    Full Text Available Modeling human aesthetic perception of visual textures is important and valuable in numerous industrial domains, such as product design, architectural design and decoration. Based on results from a semantic differential rating experiment, we modeled the relationship between low-level basic texture features and aesthetic properties involved in human aesthetic texture perception. First, we compute basic texture features from textural images using four classical methods. These features are neutral, objective and independent of the socio-cultural context of the visual textures. Then, we conduct a semantic differential rating experiment to collect from evaluators their aesthetic perceptions of selected textural stimuli. In semantic differential rating experiment, eights pairs of aesthetic properties are chosen, which are strongly related to the socio-cultural context of the selected textures and to human emotions. They are easily understood and connected to everyday life. We propose a hierarchical feed-forward layer model of aesthetic texture perception and assign 8 pairs of aesthetic properties to different layers. Finally, we describe the generation of multiple linear and nonlinear regression models for aesthetic prediction by taking dimensionality-reduced texture features and aesthetic properties of visual textures as dependent and independent variables, respectively. Our experimental results indicate that the relationships between each layer and its neighbors in the hierarchical feed-forward layer model of aesthetic texture perception can be fitted well by linear functions, and the models thus generated can successfully bridge the gap between computational texture features and aesthetic texture properties.

  8. On uniform resampling and gaze analysis of bidirectional texture functions

    Czech Academy of Sciences Publication Activity Database

    Filip, Jiří; Chantler, M.J.; Haindl, Michal

    2009-01-01

    Roč. 6, č. 3 (2009), s. 1-15 ISSN 1544-3558 R&D Projects: GA MŠk 1M0572; GA ČR GA102/08/0593 Grant - others:EC Marie Curie(BE) 41358 Institutional research plan: CEZ:AV0Z10750506 Keywords : BTF * texture * eye tracking Subject RIV: BD - Theory of Information Impact factor: 1.447, year: 2009 http://library.utia.cas.cz/separaty/2009/RO/haindl-on uniform resampling and gaze analysis of bidirectional texture functions.pdf

  9. Characterizing commercial pureed foods: sensory, nutritional, and textural analysis.

    Science.gov (United States)

    Ettinger, Laurel; Keller, Heather H; Duizer, Lisa M

    2014-01-01

    Dysphagia (swallowing impairment) is a common consequence of stroke and degenerative diseases such as Parkinson's and Alzheimer's. Limited research is available on pureed foods, specifically the qualities of commercial products. Because research has linked pureed foods, specifically in-house pureed products, to malnutrition due to inferior sensory and nutritional qualities, commercial purees also need to be investigated. Proprietary research on sensory attributes of commercial foods is available; however direct comparisons of commercial pureed foods have never been reported. Descriptive sensory analysis as well as nutritional and texture analysis of commercially pureed prepared products was performed using a trained descriptive analysis panel. The pureed foods tested included four brands of carrots, of turkey, and two of bread. Each commercial puree was analyzed for fat (Soxhlet), protein (Dumas), carbohydrate (proximate analysis), fiber (total fiber), and sodium content (Quantab titrator strips). The purees were also texturally compared with a line spread test and a back extrusion test. Differences were found in the purees for sensory attributes as well as nutritional and textural properties. Findings suggest that implementation of standards is required to reduce variability between products, specifically regarding the textural components of the products. This would ensure all commercial products available in Canada meet standards established as being considered safe for swallowing.

  10. Characterization of PET/CT images using texture analysis: the past, the present... any future?

    International Nuclear Information System (INIS)

    Hatt, Mathieu; Visvikis, Dimitris; Tixier, Florent; Le Rest, Catherine Cheze; Pierce, Larry; Kinahan, Paul E.

    2017-01-01

    After seminal papers over the period 2009 - 2011, the use of texture analysis of PET/CT images for quantification of intratumour uptake heterogeneity has received increasing attention in the last 4 years. Results are difficult to compare due to the heterogeneity of studies and lack of standardization. There are also numerous challenges to address. In this review we provide critical insights into the recent development of texture analysis for quantifying the heterogeneity in PET/CT images, identify issues and challenges, and offer recommendations for the use of texture analysis in clinical research. Numerous potentially confounding issues have been identified, related to the complex workflow for the calculation of textural features, and the dependency of features on various factors such as acquisition, image reconstruction, preprocessing, functional volume segmentation, and methods of establishing and quantifying correspondences with genomic and clinical metrics of interest. A lack of understanding of what the features may represent in terms of the underlying pathophysiological processes and the variability of technical implementation practices makes comparing results in the literature challenging, if not impossible. Since progress as a field requires pooling results, there is an urgent need for standardization and recommendations/guidelines to enable the field to move forward. We provide a list of correct formulae for usual features and recommendations regarding implementation. Studies on larger cohorts with robust statistical analysis and machine learning approaches are promising directions to evaluate the potential of this approach. (orig.)

  11. Characterization of PET/CT images using texture analysis: the past, the present... any future?

    Energy Technology Data Exchange (ETDEWEB)

    Hatt, Mathieu; Visvikis, Dimitris [University of Brest IBSAM, INSERM, UMR 1101, LaTIM, Brest (France); Tixier, Florent; Le Rest, Catherine Cheze [University Hospital, Nuclear Medicine, Poitiers (France); University of Poitiers, Medical school, EE DACTIM, Poitiers (France); Pierce, Larry; Kinahan, Paul E. [University of Washington, Imaging Research Laboratory, Seattle, WA (United States)

    2017-01-15

    After seminal papers over the period 2009 - 2011, the use of texture analysis of PET/CT images for quantification of intratumour uptake heterogeneity has received increasing attention in the last 4 years. Results are difficult to compare due to the heterogeneity of studies and lack of standardization. There are also numerous challenges to address. In this review we provide critical insights into the recent development of texture analysis for quantifying the heterogeneity in PET/CT images, identify issues and challenges, and offer recommendations for the use of texture analysis in clinical research. Numerous potentially confounding issues have been identified, related to the complex workflow for the calculation of textural features, and the dependency of features on various factors such as acquisition, image reconstruction, preprocessing, functional volume segmentation, and methods of establishing and quantifying correspondences with genomic and clinical metrics of interest. A lack of understanding of what the features may represent in terms of the underlying pathophysiological processes and the variability of technical implementation practices makes comparing results in the literature challenging, if not impossible. Since progress as a field requires pooling results, there is an urgent need for standardization and recommendations/guidelines to enable the field to move forward. We provide a list of correct formulae for usual features and recommendations regarding implementation. Studies on larger cohorts with robust statistical analysis and machine learning approaches are promising directions to evaluate the potential of this approach. (orig.)

  12. Slice simulation from a model of the parenchymous vascularization to evaluate texture features: work in progress.

    Science.gov (United States)

    Rolland, Y; Bézy-Wendling, J; Duvauferrier, R; Coatrieux, J L

    1999-03-01

    To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Parameters of statistical methods were measured on 16128x128 regions of interest, and mean values and standard deviation were calculated. For each parameter, the performances (discrimination power and stability) were evaluated. Among 11 calculated statistical parameters, three (homogeneity, entropy, mean of gradients) were found to have a good discriminating power to differentiate normal perfusion from hypervascularization, but only the gradient mean was found to have a good stability with respect to the thickness. Five parameters (run percentage, run length distribution, long run emphasis, contrast, and gray level distribution) were found to have intermediate results. In the remaining three, curtosis and correlation was found to have little discrimination power, skewness none. This 3D vascular model, which allows the generation of various examples of vascular textures, is a powerful tool to assess the performance of texture analysis methods. This improves our knowledge of the methods and should contribute to their a priori choice when designing clinical studies.

  13. Anorexia Nervosa: Analysis of Trabecular Texture with CT.

    Science.gov (United States)

    Tabari, Azadeh; Torriani, Martin; Miller, Karen K; Klibanski, Anne; Kalra, Mannudeep K; Bredella, Miriam A

    2017-04-01

    Purpose To determine indexes of skeletal integrity by using computed tomographic (CT) trabecular texture analysis of the lumbar spine in patients with anorexia nervosa and normal-weight control subjects and to determine body composition predictors of trabecular texture. Materials and Methods This cross-sectional study was approved by the institutional review board and compliant with HIPAA. Written informed consent was obtained. The study included 30 women with anorexia nervosa (mean age ± standard deviation, 26 years ± 6) and 30 normal-weight age-matched women (control group). All participants underwent low-dose single-section quantitative CT of the L4 vertebral body with use of a calibration phantom. Trabecular texture analysis was performed by using software. Skewness (asymmetry of gray-level pixel distribution), kurtosis (pointiness of pixel distribution), entropy (inhomogeneity of pixel distribution), and mean value of positive pixels (MPP) were assessed. Bone mineral density and abdominal fat and paraspinal muscle areas were quantified with quantitative CT. Women with anorexia nervosa and normal-weight control subjects were compared by using the Student t test. Linear regression analyses were performed to determine associations between trabecular texture and body composition. Results Women with anorexia nervosa had higher skewness and kurtosis, lower MPP (P anorexia nervosa. Conclusion Patients with anorexia nervosa had increased skewness and kurtosis and decreased entropy and MPP compared with normal-weight control subjects. These parameters were associated with lowest lifetime weight and duration of amenorrhea, but there were no such associations with bone mineral density. These findings suggest that trabecular texture analysis might contribute information about bone health in anorexia nervosa that is independent of that provided with bone mineral density. © RSNA, 2016.

  14. X-ray stress analysis in textured polycrystalline materials

    International Nuclear Information System (INIS)

    Yokoyama, Ryouichi; Harada, Jimpei

    2010-01-01

    The relationship between stress and strain in polycrystalline materials with fibre texture is examined on the basis of the strain analysis in the constituent crystallites within the Reuss approximation. By introducing the symmetry of reciprocal lattices for the constituent crystallites, the physical meaning of taking an average of the strains observed by X-ray diffraction (XRD) is made clear. By using formulae obtained by the present treatment for the stress-strain relation in cubic specimens with fibre texture in the Laue classes m3-bar m hkl Bragg reflections with h≠k≠l split into doublets owing to the existence of crystallites with two different orientations under the stress field. This technique was confirmed by the profile analysis in XRD data observed for reflections of 222 and 420 in a cubic TiN thin film sputtered on a polyimide film. The technique of the stress analysis and its confirmation are introduced. (author)

  15. Robust Face Recognition Based on Texture Analysis

    Directory of Open Access Journals (Sweden)

    Sanun Srisuk

    2013-01-01

    Full Text Available In this paper, we present a new framework for face recognition with varying illumination based on DCT total variation minimization (DTV, a Gabor filter, a sub-micro-pattern analysis (SMP and discriminated accumulative feature transform (DAFT. We first suppress the illumination effect by using the DCT with the help of TV as a tool for face normalization. The DTV image is then emphasized by the Gabor filter. The facial features are encoded by our proposed method - the SMP. The SMP image is then transformed to the 2D histogram using DAFT. Our system is verified with experiments on the AR and the Yale face database B.

  16. About normal distribution on SO(3) group in texture analysis

    Science.gov (United States)

    Savyolova, T. I.; Filatov, S. V.

    2017-12-01

    This article studies and compares different normal distributions (NDs) on SO(3) group, which are used in texture analysis. Those NDs are: Fisher normal distribution (FND), Bunge normal distribution (BND), central normal distribution (CND) and wrapped normal distribution (WND). All of the previously mentioned NDs are central functions on SO(3) group. CND is a subcase for normal CLT-motivated distributions on SO(3) (CLT here is Parthasarathy’s central limit theorem). WND is motivated by CLT in R 3 and mapped to SO(3) group. A Monte Carlo method for modeling normally distributed values was studied for both CND and WND. All of the NDs mentioned above are used for modeling different components of crystallites orientation distribution function in texture analysis.

  17. 2D magnetic texture analysis of Co-Cu films

    International Nuclear Information System (INIS)

    Bayirli, Mehmet; Karaagac, Oznur; Kockar, Hakan; Alper, Mursel

    2017-01-01

    The magnetic textures for the produced magnetic materials are important concepts in accordance with technical applications. Therefore, the aim of this article is to determine 2D magnetic textures of electrodeposited Co-Cu films by the measurement of hysteresis loops at the incremented angles. For that, Co-Cu films were deposited with different Co"2"+ in the electrolyte. In addition, the easy-axis orientation in the films from the squareness values of the angles, M_p(β) obtained by the hysteresis loops have been numerically studied using the Fourier series analysis. The differences observed in the magnetic easy-axis distributions were attributed to changes of the incorporation of Co in the films with the change of Co"2"+ in the electrolyte. The coefficients of Fourier series (A_0 and A_2_n) were also computed for 2D films. It is seen that a systematic and small decrease in A_0 and an obvious decrease in A_2_n (n=1) were observed with increasing incorporated Co in the films. Results imply that interactions cause slightly demagnetization effect accordance with higher incorporation of Co in the films. Furthermore, the crystal structure of the Co-Cu films analysed by X-ray diffraction revealed that the films have dominantly face-centred cubic structure. Film contents analysed by energy-dispersive X-ray spectroscopy and film morphologies observed by scanning electron microscope also support the magnetic texture analysis results found by numerical computation.

  18. Sensory texture analysis of thickened liquids during ingestion.

    Science.gov (United States)

    Chambers, Edgar; Jenkins, Alicia; Mertz Garcia, Jane

    2017-12-01

    Practitioners support the use of thickened liquids for many patients with disordered swallowing. Although physical measures have highlighted differences among products there are questions about the ability of the measures to fully explain the sensory texture effects during swallowing of thickened liquids. This study used a trained sensory panel to describe the textural aspects of liquids during ingestion and swallowing. The lexicon was able to characterize differences in beverages, thickeners, and thickness levels with the most important attribute being viscosity, which loaded heavily in the almost one-dimensional space that resulted from the sensory analysis of these beverages. Other effects, such as slipperiness provided some minimal additional information on the products. Trained sensory panelists were shown to be useful in the measurement of differences in thickened liquid products prescribed for patients with dysphagia. They were able to differentiate products based on perceived differences related to flow speed, viscosity, and other parameters suggesting their use in further studies of swallowing behavior and for development of products for disordered swallowing should be considered. Understanding how these variables might relate to clinical decision making about product selection or modification to best meet the nutritional needs of a person with disordered swallowing could be helpful. This is especially true given the difficulties in measuring texture instrumentally in these products. © 2017 Wiley Periodicals, Inc.

  19. Deep neural networks for texture classification-A theoretical analysis.

    Science.gov (United States)

    Basu, Saikat; Mukhopadhyay, Supratik; Karki, Manohar; DiBiano, Robert; Ganguly, Sangram; Nemani, Ramakrishna; Gayaka, Shreekant

    2018-01-01

    We investigate the use of Deep Neural Networks for the classification of image datasets where texture features are important for generating class-conditional discriminative representations. To this end, we first derive the size of the feature space for some standard textural features extracted from the input dataset and then use the theory of Vapnik-Chervonenkis dimension to show that hand-crafted feature extraction creates low-dimensional representations which help in reducing the overall excess error rate. As a corollary to this analysis, we derive for the first time upper bounds on the VC dimension of Convolutional Neural Network as well as Dropout and Dropconnect networks and the relation between excess error rate of Dropout and Dropconnect networks. The concept of intrinsic dimension is used to validate the intuition that texture-based datasets are inherently higher dimensional as compared to handwritten digits or other object recognition datasets and hence more difficult to be shattered by neural networks. We then derive the mean distance from the centroid to the nearest and farthest sampling points in an n-dimensional manifold and show that the Relative Contrast of the sample data vanishes as dimensionality of the underlying vector space tends to infinity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Application of texture analysis method for mammogram density classification

    Science.gov (United States)

    Nithya, R.; Santhi, B.

    2017-07-01

    Mammographic density is considered a major risk factor for developing breast cancer. This paper proposes an automated approach to classify breast tissue types in digital mammogram. The main objective of the proposed Computer-Aided Diagnosis (CAD) system is to investigate various feature extraction methods and classifiers to improve the diagnostic accuracy in mammogram density classification. Texture analysis methods are used to extract the features from the mammogram. Texture features are extracted by using histogram, Gray Level Co-Occurrence Matrix (GLCM), Gray Level Run Length Matrix (GLRLM), Gray Level Difference Matrix (GLDM), Local Binary Pattern (LBP), Entropy, Discrete Wavelet Transform (DWT), Wavelet Packet Transform (WPT), Gabor transform and trace transform. These extracted features are selected using Analysis of Variance (ANOVA). The features selected by ANOVA are fed into the classifiers to characterize the mammogram into two-class (fatty/dense) and three-class (fatty/glandular/dense) breast density classification. This work has been carried out by using the mini-Mammographic Image Analysis Society (MIAS) database. Five classifiers are employed namely, Artificial Neural Network (ANN), Linear Discriminant Analysis (LDA), Naive Bayes (NB), K-Nearest Neighbor (KNN), and Support Vector Machine (SVM). Experimental results show that ANN provides better performance than LDA, NB, KNN and SVM classifiers. The proposed methodology has achieved 97.5% accuracy for three-class and 99.37% for two-class density classification.

  1. An Analysis of the Max-Min Texture Measure.

    Science.gov (United States)

    1982-01-01

    PANC 33 D2 Confusion Matrices for Scene A, IR 34 D3 Confusion Matrices for Scene B, PANC 35 D4 Confusion Matrices for Scene B, IR 36 D5 Confusion...Matrices for Scene C, PANC 37 D6 Confusion Matrices for Scene C, IR 38 D7 Confusion Matrices for Scene E, PANC 39 D8 Confusion Matrices for Scene E, IR 40...D9 Confusion Matrices for Scene H, PANC 41 DIO Confusion Matrices for Scene H, JR 42 3 .D 10CnuinMtie o cn ,IR4 AN ANALYSIS OF THE MAX-MIN TEXTURE

  2. Linear feature selection in texture analysis - A PLS based method

    DEFF Research Database (Denmark)

    Marques, Joselene; Igel, Christian; Lillholm, Martin

    2013-01-01

    We present a texture analysis methodology that combined uncommitted machine-learning techniques and partial least square (PLS) in a fully automatic framework. Our approach introduces a robust PLS-based dimensionality reduction (DR) step to specifically address outliers and high-dimensional feature...... and considering all CV groups, the methods selected 36 % of the original features available. The diagnosis evaluation reached a generalization area-under-the-ROC curve of 0.92, which was higher than established cartilage-based markers known to relate to OA diagnosis....

  3. 2D magnetic texture analysis of Co-Cu films

    Energy Technology Data Exchange (ETDEWEB)

    Bayirli, Mehmet; Karaagac, Oznur; Kockar, Hakan [Balikesir Univ. (Turkey). Physics Dept.; Alper, Mursel [Uludag Univ., Bursa (Turkey). Physics Dept.

    2017-08-01

    The magnetic textures for the produced magnetic materials are important concepts in accordance with technical applications. Therefore, the aim of this article is to determine 2D magnetic textures of electrodeposited Co-Cu films by the measurement of hysteresis loops at the incremented angles. For that, Co-Cu films were deposited with different Co{sup 2+} in the electrolyte. In addition, the easy-axis orientation in the films from the squareness values of the angles, M{sub p}(β) obtained by the hysteresis loops have been numerically studied using the Fourier series analysis. The differences observed in the magnetic easy-axis distributions were attributed to changes of the incorporation of Co in the films with the change of Co{sup 2+} in the electrolyte. The coefficients of Fourier series (A{sub 0} and A{sub 2n}) were also computed for 2D films. It is seen that a systematic and small decrease in A{sub 0} and an obvious decrease in A{sub 2n} (n=1) were observed with increasing incorporated Co in the films. Results imply that interactions cause slightly demagnetization effect accordance with higher incorporation of Co in the films. Furthermore, the crystal structure of the Co-Cu films analysed by X-ray diffraction revealed that the films have dominantly face-centred cubic structure. Film contents analysed by energy-dispersive X-ray spectroscopy and film morphologies observed by scanning electron microscope also support the magnetic texture analysis results found by numerical computation.

  4. TEXTURE ANALYSIS OF EXTRUDED APPLE POMACE - WHEAT SEMOLINA BLENDS

    Directory of Open Access Journals (Sweden)

    Ivan Bakalov

    2016-03-01

    Full Text Available Apple pomace - wheat semolina blends were extruded in a laboratory single screw extruder (Brabender 20 DN, Germany. Effects apple pomace content, moisture content, screw speed, and temperature of final cooking zone on texture of extrudates were studied applying response surface methodology. The texture characteristics of the extrudates were measured using a TA.XT Plus Texture Analyser, Stable Micro Systems.

  5. X-ray texture analysis of paper coating pigments and the correlation with chemical composition analysis

    Science.gov (United States)

    Roine, J.; Tenho, M.; Murtomaa, M.; Lehto, V.-P.; Kansanaho, R.

    2007-10-01

    The present research experiments the applicability of x-ray texture analysis in investigating the properties of paper coatings. The preferred orientations of kaolin, talc, ground calcium carbonate, and precipitated calcium carbonate particles used in four different paper coatings were determined qualitatively based on the measured crystal orientation data. The extent of the orientation, namely, the degree of the texture of each pigment, was characterized quantitatively using a single parameter. As a result, the effect of paper calendering is clearly seen as an increase on the degree of texture of the coating pigments. The effect of calendering on the preferred orientation of kaolin was also evident in an independent energy dispersive spectrometer analysis on micrometer scale and an electron spectroscopy for chemical analysis on nanometer scale. Thus, the present work proves x-ray texture analysis to be a potential research tool for characterizing the properties of paper coating layers.

  6. Magnetic resonance imaging texture analysis classification of primary breast cancer

    International Nuclear Information System (INIS)

    Waugh, S.A.; Lerski, R.A.; Purdie, C.A.; Jordan, L.B.; Vinnicombe, S.; Martin, P.; Thompson, A.M.

    2016-01-01

    Patient-tailored treatments for breast cancer are based on histological and immunohistochemical (IHC) subtypes. Magnetic Resonance Imaging (MRI) texture analysis (TA) may be useful in non-invasive lesion subtype classification. Women with newly diagnosed primary breast cancer underwent pre-treatment dynamic contrast-enhanced breast MRI. TA was performed using co-occurrence matrix (COM) features, by creating a model on retrospective training data, then prospectively applying to a test set. Analyses were blinded to breast pathology. Subtype classifications were performed using a cross-validated k-nearest-neighbour (k = 3) technique, with accuracy relative to pathology assessed and receiver operator curve (AUROC) calculated. Mann-Whitney U and Kruskal-Wallis tests were used to assess raw entropy feature values. Histological subtype classifications were similar across training (n = 148 cancers) and test sets (n = 73 lesions) using all COM features (training: 75 %, AUROC = 0.816; test: 72.5 %, AUROC = 0.823). Entropy features were significantly different between lobular and ductal cancers (p < 0.001; Mann-Whitney U). IHC classifications using COM features were also similar for training and test data (training: 57.2 %, AUROC = 0.754; test: 57.0 %, AUROC = 0.750). Hormone receptor positive and negative cancers demonstrated significantly different entropy features. Entropy features alone were unable to create a robust classification model. Textural differences on contrast-enhanced MR images may reflect underlying lesion subtypes, which merits testing against treatment response. (orig.)

  7. Magnetic resonance imaging texture analysis classification of primary breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, S.A.; Lerski, R.A. [Ninewells Hospital and Medical School, Department of Medical Physics, Dundee (United Kingdom); Purdie, C.A.; Jordan, L.B. [Ninewells Hospital and Medical School, Department of Pathology, Dundee (United Kingdom); Vinnicombe, S. [University of Dundee, Division of Imaging and Technology, Ninewells Hospital and Medical School, Dundee (United Kingdom); Martin, P. [Ninewells Hospital and Medical School, Department of Clinical Radiology, Dundee (United Kingdom); Thompson, A.M. [University of Texas MD Anderson Cancer Center, Department of Surgical Oncology, Houston, TX (United States)

    2016-02-15

    Patient-tailored treatments for breast cancer are based on histological and immunohistochemical (IHC) subtypes. Magnetic Resonance Imaging (MRI) texture analysis (TA) may be useful in non-invasive lesion subtype classification. Women with newly diagnosed primary breast cancer underwent pre-treatment dynamic contrast-enhanced breast MRI. TA was performed using co-occurrence matrix (COM) features, by creating a model on retrospective training data, then prospectively applying to a test set. Analyses were blinded to breast pathology. Subtype classifications were performed using a cross-validated k-nearest-neighbour (k = 3) technique, with accuracy relative to pathology assessed and receiver operator curve (AUROC) calculated. Mann-Whitney U and Kruskal-Wallis tests were used to assess raw entropy feature values. Histological subtype classifications were similar across training (n = 148 cancers) and test sets (n = 73 lesions) using all COM features (training: 75 %, AUROC = 0.816; test: 72.5 %, AUROC = 0.823). Entropy features were significantly different between lobular and ductal cancers (p < 0.001; Mann-Whitney U). IHC classifications using COM features were also similar for training and test data (training: 57.2 %, AUROC = 0.754; test: 57.0 %, AUROC = 0.750). Hormone receptor positive and negative cancers demonstrated significantly different entropy features. Entropy features alone were unable to create a robust classification model. Textural differences on contrast-enhanced MR images may reflect underlying lesion subtypes, which merits testing against treatment response. (orig.)

  8. Automated detection of regions of interest for tissue microarray experiments: an image texture analysis

    International Nuclear Information System (INIS)

    Karaçali, Bilge; Tözeren, Aydin

    2007-01-01

    Recent research with tissue microarrays led to a rapid progress toward quantifying the expressions of large sets of biomarkers in normal and diseased tissue. However, standard procedures for sampling tissue for molecular profiling have not yet been established. This study presents a high throughput analysis of texture heterogeneity on breast tissue images for the purpose of identifying regions of interest in the tissue for molecular profiling via tissue microarray technology. Image texture of breast histology slides was described in terms of three parameters: the percentage of area occupied in an image block by chromatin (B), percentage occupied by stroma-like regions (P), and a statistical heterogeneity index H commonly used in image analysis. Texture parameters were defined and computed for each of the thousands of image blocks in our dataset using both the gray scale and color segmentation. The image blocks were then classified into three categories using the texture feature parameters in a novel statistical learning algorithm. These categories are as follows: image blocks specific to normal breast tissue, blocks specific to cancerous tissue, and those image blocks that are non-specific to normal and disease states. Gray scale and color segmentation techniques led to identification of same regions in histology slides as cancer-specific. Moreover the image blocks identified as cancer-specific belonged to those cell crowded regions in whole section image slides that were marked by two pathologists as regions of interest for further histological studies. These results indicate the high efficiency of our automated method for identifying pathologic regions of interest on histology slides. Automation of critical region identification will help minimize the inter-rater variability among different raters (pathologists) as hundreds of tumors that are used to develop an array have typically been evaluated (graded) by different pathologists. The region of interest

  9. Automated migration analysis based on cell texture: method & reliability

    Directory of Open Access Journals (Sweden)

    Chittenden Thomas W

    2005-03-01

    Full Text Available Abstract Background In this paper, we present and validate a way to measure automatically the extent of cell migration based on automated examination of a series of digital photographs. It was designed specifically to identify the impact of Second Hand Smoke (SHS on endothelial cell migration but has broader applications. The analysis has two stages: (1 preprocessing of image texture, and (2 migration analysis. Results The output is a graphic overlay that indicates the front lines of cell migration superimposed on each original image, with automated reporting of the distance traversed vs. time. Expert preference compares to manual placement of leading edge shows complete equivalence of automated vs. manual leading edge definition for cell migration measurement. Conclusion Our method is indistinguishable from careful manual determinations of cell front lines, with the advantages of full automation, objectivity, and speed.

  10. Texture analysis using angle dispersive neutron nuclear scattering

    International Nuclear Information System (INIS)

    Brokmeier, H.G.

    1995-01-01

    This paper describes in detail the method of texture determination using neutron diffraction. The main advantages of neutron diffraction arise from the high penetration depth for most materials which is a factor of 10 2 -10 4 higher than for X-ray diffraction. Consequently neutron diffraction is an efficient tool for the investigation of global textures and coarse grained materials. Moreover, the measurement of large sample volumes gives excellent grain statistics, allows the influence of texture inhomogeneities to be neglected and allows the measurement of complete pole figures even of minority phases. A number of examples show the application of neutron diffraction to measure textures of metals, alloys, composites, intermetallic compounds and rocks. A detailed description of TEX-2 the neutron texture diffractometer at GKSS Research Centre is given which is completed by a comparison to other neutron texture diffractometers. (orig.) [de

  11. Diagnostic Performance of Mammographic Texture Analysis in the Differential Diagnosis of Benign and Malignant Breast Tumors.

    Science.gov (United States)

    Li, Zhiming; Yu, Lan; Wang, Xin; Yu, Haiyang; Gao, Yuanxiang; Ren, Yande; Wang, Gang; Zhou, Xiaoming

    2017-11-09

    The purpose of this study was to investigate the diagnostic performance of mammographic texture analysis in the differential diagnosis of benign and malignant breast tumors. Digital mammography images were obtained from the Picture Archiving and Communication System at our institute. Texture features of mammographic images were calculated. Mann-Whitney U test was used to identify differences between the benign and malignant group. The receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic performance of texture features. Significant differences of texture features of histogram, gray-level co-occurrence matrix (GLCM) and run length matrix (RLM) were found between the benign and malignant breast group (P  .05). The AUROCs of imaging-based diagnosis, texture analysis, and imaging-based diagnosis combined with texture analysis were 0.873, 0.863, and 0.961, respectively. When imaging-based diagnosis was combined with texture analysis, the AUROC was higher than that of imaging-based diagnosis or texture analysis (P benign and malignant breast tumors. Furthermore, the combination of imaging-based diagnosis and texture analysis can significantly improve diagnostic performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Soil texture analysis by laser diffraction - standardization needed

    DEFF Research Database (Denmark)

    Callesen, Ingeborg; Palviainen, M.; Kjønaas, O. Janne

    2017-01-01

    Soil texture is a central soil quality property. Laser diffraction (LD) for determination of particle size distribution (PSD) is now widespread due to easy analysis and low cost. However, pretreatment methods and interpretation of the resulting soil PSD’s are not standardized. Comparison of LD data...... with sedimentation and sieving data may cause misinterpretation and confusion. In literature that reports PSD’s based on LD, pretreatment methods, operating procedures and data methods are often underreported or not reported, although literature stressing the importance exists (e.g. Konert and Vandenberghe, 1997...... and many newer; ISO 13320:2009). PSD uncertainty caused by pretreatments and PSD bias caused by plate-shaped clay particles still calls for more method standardization work. If LD is used more generally, new pedotransfer functions for other soil properties (e.g water retention) based on sieving...

  13. Characterisation of radiotherapy planning volumes using textural analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nailon, William H.; Redpath, Anthony T.; McLaren, Duncan B. (Dept. of Oncology Physics, Edinburgh Cancer Centre, Western General Hospital, Edinburgh (United Kingdom))

    2008-08-15

    Computer-based artificial intelligence methods for classification and delineation of the gross tumour volume (GTV) on computerised tomography (CT) and magnetic resonance (MR) images do not, at present, provide the accuracy required for radiotherapy applications. This paper describes an image analysis method for classification of distinct regions within the GTV, and other clinically relevant regions, on CT images acquired on eight bladder cancer patients at the radiotherapy planning stage and thereafter at regular intervals during treatment. Statistical and fractal textural features (N=27) were calculated on the bladder, rectum and a control region identified on axial, coronal and sagittal CT images. Unsupervised classification results demonstrate that with a reduced feature set (N=3) the approach offers significant classification accuracy on axial, coronal and sagittal CT image planes and has the potential to be developed further for radiotherapy applications, particularly towards an automatic outlining approach

  14. Characterisation of radiotherapy planning volumes using textural analysis

    International Nuclear Information System (INIS)

    Nailon, William H.; Redpath, Anthony T.; McLaren, Duncan B.

    2008-01-01

    Computer-based artificial intelligence methods for classification and delineation of the gross tumour volume (GTV) on computerised tomography (CT) and magnetic resonance (MR) images do not, at present, provide the accuracy required for radiotherapy applications. This paper describes an image analysis method for classification of distinct regions within the GTV, and other clinically relevant regions, on CT images acquired on eight bladder cancer patients at the radiotherapy planning stage and thereafter at regular intervals during treatment. Statistical and fractal textural features (N=27) were calculated on the bladder, rectum and a control region identified on axial, coronal and sagittal CT images. Unsupervised classification results demonstrate that with a reduced feature set (N=3) the approach offers significant classification accuracy on axial, coronal and sagittal CT image planes and has the potential to be developed further for radiotherapy applications, particularly towards an automatic outlining approach

  15. Predicting neo-adjuvant chemotherapy response and progression-free survival of locally advanced breast cancer using textural features of intratumoral heterogeneity on F-18 FDG PET/CT and diffusion-weighted MR imaging.

    Science.gov (United States)

    Yoon, Hai-Jeon; Kim, Yemi; Chung, Jin; Kim, Bom Sahn

    2018-03-30

    Predicting response to neo-adjuvant chemotherapy (NAC) and survival in locally advanced breast cancer (LABC) is important. This study investigated the prognostic value of tumor heterogeneity evaluated with textural analysis through F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) and diffusion-weighted imaging (DWI). We enrolled 83 patients with LABC who had completed NAC and curative surgery. Tumor texture indices from pretreatment FDG PET and DWI were extracted from histogram analysis and 7 different parent matrices: co-occurrence matrix, the voxel-alignment matrix, neighborhood intensity difference matrix, intensity size-zone matrix (ISZM), normalized gray-level co-occurrence matrix (NGLCM), neighboring gray-level dependence matrix (NGLDM), and texture spectrum matrix. The predictive values of textural features were tested regarding both pathologic NAC response and progression-free survival. Among 83 patients, 46 were pathologic responders, while 37 were nonresponders. The PET texture indices from 7 parent matrices, DWI texture indices from histogram, and 1 parent matrix (NGLCM) showed significant differences according to NAC response. On multivariable analysis, number nonuniformity of PET extracted from the NGLDM was an independent predictor of pathologic response (P = .009). During a median follow-up period of 17.3 months, 14 patients experienced recurrence. High-intensity zone emphasis (HIZE) and high-intensity short-zone emphasis (HISZE) from PET extracted from ISZM were significant textural predictors (P = .011 and P = .033). On Cox regression analysis, only HIZE was a significant predictor of recurrence (P = .027), while HISZE showed borderline significance (P = .107). Tumor texture indices are useful for NAC response prediction in LABC. Moreover, PET texture indices can help to predict disease recurrence. © 2018 Wiley Periodicals, Inc.

  16. Image segmentation and particles classification using texture analysis method

    Directory of Open Access Journals (Sweden)

    Mayar Aly Atteya

    Full Text Available Introduction: Ingredients of oily fish include a large amount of polyunsaturated fatty acids, which are important elements in various metabolic processes of humans, and have also been used to prevent diseases. However, in an attempt to reduce cost, recent developments are starting a replace the ingredients of fish oil with products of microalgae, that also produce polyunsaturated fatty acids. To do so, it is important to closely monitor morphological changes in algae cells and monitor their age in order to achieve the best results. This paper aims to describe an advanced vision-based system to automatically detect, classify, and track the organic cells using a recently developed SOPAT-System (Smart On-line Particle Analysis Technology, a photo-optical image acquisition device combined with innovative image analysis software. Methods The proposed method includes image de-noising, binarization and Enhancement, as well as object recognition, localization and classification based on the analysis of particles’ size and texture. Results The methods allowed for correctly computing cell’s size for each particle separately. By computing an area histogram for the input images (1h, 18h, and 42h, the variation could be observed showing a clear increase in cell. Conclusion The proposed method allows for algae particles to be correctly identified with accuracies up to 99% and classified correctly with accuracies up to 100%.

  17. Minimizing inter-microscope variability in dental microwear texture analysis

    Science.gov (United States)

    Arman, Samuel D.; Ungar, Peter S.; Brown, Christopher A.; DeSantis, Larisa R. G.; Schmidt, Christopher; Prideaux, Gavin J.

    2016-06-01

    A common approach to dental microwear texture analysis (DMTA) uses confocal profilometry in concert with scale-sensitive fractal analysis to help understand the diets of extinct mammals. One of the main benefits of DMTA over other methods is the repeatable, objective manner of data collection. This repeatability, however, is threatened by variation in results of DMTA of the same dental surfaces yielded by different microscopes. Here we compare DMTA data of five species of kangaroos measured on seven profilers of varying specifications. Comparison between microscopes confirms that inter-microscope differences are present, but we show that deployment of a number of automated treatments to remove measurement noise can help minimize inter-microscope differences. Applying these same treatments to a published hominin DMTA dataset shows that they alter some significant differences between dietary groups. Minimising microscope variability while maintaining interspecific dietary differences requires then that these factors are balanced in determining appropriate treatments. The process outlined here offers a solution for allowing comparison of data between microscopes, which is essential for ongoing DMTA research. In addition, the process undertaken, including considerations of other elements of DMTA protocols also promises to streamline methodology, remove measurement noise and in doing so, optimize recovery of a reliable dietary signature.

  18. Quantitative phase analysis of a highly textured industrial sample using a Rietveld profile analysis

    International Nuclear Information System (INIS)

    Shin, Eunjoo; Huh, Moo-Young; Seong, Baek-Seok; Lee, Chang-Hee

    2001-01-01

    For the quantitative phase analysis on highly textured two-phase materials, samples with known weight fractions of zirconium and aluminum were prepared. Strong texture components prevailed in both zirconium and aluminum sheet. The diffraction patterns of samples were measured by the neutron and refined by the Rietveld method. The preferred orientation correction of diffraction patterns was carried out by means of recalculated pole figures from the ODF. The present Rietveld analysis of various samples with different weight fractions showed that the absolute error of the calculated weight fractions was less than 7.1%. (author)

  19. Texture and microstructure analysis of epitaxial oxide layers prepared on textured Ni-12wt%Cr tapes

    Energy Technology Data Exchange (ETDEWEB)

    Huehne, R; Kursumovic, A; Tomov, R I; Glowacki, B A [Department of Materials Science and IRC in Superconductivity, University of Cambridge, Pembroke Street, Cambridge, CB2 3QZ (United Kingdom); Holzapfel, B [Institut fuer Festkoerper- und Werkstoffforschung, Helmholtzstrasse 20, 01069 Dresden (Germany); Evetts, J E [Department of Materials Science and IRC in Superconductivity, University of Cambridge, Pembroke Street, Cambridge, CB2 3QZ (United Kingdom)

    2003-05-07

    Oxide layers for the preparation of YBa{sub 2}Cu{sub 3}O{sub 7-x} coated conductors were grown on highly textured Ni-12wt%Cr tapes in pure oxygen using surface oxidation epitaxy at temperatures between 1000 deg. C and 1300 deg. C. Microstructural investigations revealed a layered oxide structure. The upper layer consists mainly of dense cube textured NiO. This is followed by a porous layer containing NiO and NiCr{sub 2}O{sub 4} particles. A detailed texture analysis showed a cube-on-cube relationship of the NiCr{sub 2}O{sub 4} spinel to the metal substrate. Untextured Cr{sub 2}O{sub 3} particles in a nickel matrix were found in a third layer arising from internal oxidation of the alloy. A high surface roughness and mechanical instability of the oxide were observed, depending on oxidation temperature and film thickness. However, mechanically stable oxide layers have been prepared using an additional annealing step in a protective atmosphere. Additionally, mechanical polishing or a second buffer layer, which grows with a higher smoothness, may be applied to reduce the surface roughness for coated conductor applications.

  20. Assessment Of Mold-Design Dependent Textures In CIM-Components By Polarized Light Optical Texture Analysis (PLOTA)

    International Nuclear Information System (INIS)

    Kern, Frank; Rauch, Johannes; Gadow, Rainer

    2007-01-01

    By thermoplastic ceramic injection moulding (CIM) ceramic components of high complexity can be produced in a large number of items at low dimensional tolerances. The cost advantage by the high degree of automation leads to an economical mass-production. The structure of injection-moulded components is determined by the form filling behaviour and viscosity of the feedstock, the machine parameters, the design of the mold and the gate design. With an adapted mold- and gate-design CIM-components without textures are possible. The ''Polarized Light Optical Texture analysis'' (PLOTA) makes it possible to inspect the components and detect and quantify the textures produced by a new mold. Based on the work of R. Fischer (2004) the PLOTA procedure was improved by including the possibility to measure the inclination angle and thus describe the orientation of the grains in three dimensions. Sampled thin sections of ceramic components are analysed under the polarization microscope and are brought in diagonal position. Pictures are taken with a digital camera. The pictures are converted in the L*a*b*- colour space and the crystals color values a* and b* in the picture are measured. The color values are compared with the values of a quartz wedge, which serves as universal standard. From the received values the inclination angle can be calculated relative to the microscope axis. It is possible to use the received data quantitatively e.g. for the FEM supported simulation of texture-conditioned divergences of mechanical values. Thus the injection molding parameters can be optimized to obtain improved mechanical properties

  1. TEXTURAL FRACTOGRAPHY

    Directory of Open Access Journals (Sweden)

    Hynek Lauschmann

    2011-05-01

    Full Text Available The reconstitution of the history of a fatigue process is based on the knowledge of any correspondences between the morphology of the crack surface and the velocity of the crack growth (crack growth rate - CGR. The textural fractography is oriented to mezoscopic SEM magnifications (30 to 500x. Images contain complicated textures without distinct borders. The aim is to find any characteristics of this texture, which correlate with CGR. Pre-processing of images is necessary to obtain a homogeneous texture. Three methods of textural analysis have been developed and realized as computational programs: the method based on the spectral structure of the image, the method based on a Gibbs random field (GRF model, and the method based on the idealization of light objects into a fibre process. In order to extract and analyze the fibre process, special methods - tracing fibres and a database-oriented analysis of a fibre process - have been developed.

  2. A neural network detection model of spilled oil based on the texture analysis of SAR image

    Science.gov (United States)

    An, Jubai; Zhu, Lisong

    2006-01-01

    A Radial Basis Function Neural Network (RBFNN) Model is investigated for the detection of spilled oil based on the texture analysis of SAR imagery. In this paper, to take the advantage of the abundant texture information of SAR imagery, the texture features are extracted by both wavelet transform and the Gray Level Co-occurrence matrix. The RBFNN Model is fed with a vector of these texture features. The RBFNN Model is trained and tested by the sample data set of the feature vectors. Finally, a SAR image is classified by this model. The classification results of a spilled oil SAR image show that the classification accuracy for oil spill is 86.2 by the RBFNN Model using both wavelet texture and gray texture, while the classification accuracy for oil spill is 78.0 by same RBFNN Model using only wavelet texture as the input of this RBFNN model. The model using both wavelet transform and the Gray Level Co-occurrence matrix is more effective than that only using wavelet texture. Furthermore, it keeps the complicated proximity and has a good performance of classification.

  3. Adding Texture to Color: Quantitative Analysis of Color Emotions

    NARCIS (Netherlands)

    Lucassen, M.P.; Gevers, T.; Gijsenij, A.

    2010-01-01

    What happens to color emotion responses when texture is added to color samples? To quantify this we performed an experiment in which subjects ordered samples (displayed on a computer monitor) along four scales: Warm-Cool, Masculine-Feminine, Hard-Soft and Heavy-Light. Three sample types were used:

  4. Application of texture analysis in tear film surface assessment based on videokeratoscopy

    Directory of Open Access Journals (Sweden)

    David Alonso-Caneiro

    2013-10-01

    Conclusions: Texture analysis of videokeratoscopy images is applicable to study tear film anomalies in dry eye subjects. The proposed technique appears to have demonstrated its clinical relevance and utility.

  5. Texture analysis of computed tomography images of acute ischemic stroke patients

    International Nuclear Information System (INIS)

    Oliveira, M.S.; Castellano, G.; Fernandes, P.T.; Avelar, W.M.; Santos, S.L.M.; Li, L.M.

    2009-01-01

    Computed tomography (CT) images are routinely used to assess ischemic brain stroke in the acute phase. They can provide important clues about whether to treat the patient by thrombolysis with tissue plasminogen activator. However, in the acute phase, the lesions may be difficult to detect in the images using standard visual analysis. The objective of the present study was to determine if texture analysis techniques applied to CT images of stroke patients could differentiate between normal tissue and affected areas that usually go unperceived under visual analysis. We performed a pilot study in which texture analysis, based on the gray level co-occurrence matrix, was applied to the CT brain images of 5 patients and of 5 control subjects and the results were compared by discriminant analysis. Thirteen regions of interest, regarding areas that may be potentially affected by ischemic stroke, were selected for calculation of texture parameters. All regions of interest for all subjects were classified as lesional or non-lesional tissue by an expert neuroradiologist. Visual assessment of the discriminant analysis graphs showed differences in the values of texture parameters between patients and controls, and also between texture parameters for lesional and non-lesional tissue of the patients. This suggests that texture analysis can indeed be a useful tool to help neurologists in the early assessment of ischemic stroke and quantification of the extent of the affected areas. (author)

  6. Comparison of textural atributes of selected meat sausages using instrumental analysis

    OpenAIRE

    Vladimír Vietoris; Ľubomír Lopašovský; Peter Zajác; Jozef Čurlej; Jozef Čapla

    2013-01-01

    The aim of the study was to compare textural atributes of selected meat sausages using instrumental analysis. For this purpose, seven different meat sausage samples were treated by instrumental analysis, by the use of Warner-Bratzler probe,  to find differences for two selected textural parameter firmness and work of shear. As expected, various values of mentioned atributes were obtained for different samples tested in fresh stage and after storage under controlled conditions (48 hrs., 30 °...

  7. Chemometric approach to texture profile analysis of kombucha fermented milk products.

    Science.gov (United States)

    Malbaša, Radomir; Jevrić, Lidija; Lončar, Eva; Vitas, Jasmina; Podunavac-Kuzmanović, Sanja; Milanović, Spasenija; Kovačević, Strahinja

    2015-09-01

    In the present work, relationships between the textural characteristics of fermented milk products obtained by kombucha inoculums with various teas were investigated by using chemometric analysis. The presented data which describe numerically the textural characteristics (firmness, consistency, cohesiveness and index of viscosity) were analysed. The quadratic correlation was determined between the textural characteristics of fermented milk products obtained at fermentation temperatures of 40 and 43 °C, using milk with 0.8, 1.6 and 2.8% milk fat and kombucha inoculums cultivated on the extracts of peppermint, stinging nettle, wild thyme and winter savory. Hierarchical cluster analysis (HCA) was performed to identify the similarities among the fermented products. The best mathematical models predicting the textural characteristics of investigated samples were developed. The results of this study indicate that textural characteristics of sample based on winter savory have a significant effect on textural characteristics of samples based on peppermint, stinging nettle and wild thyme, which can be very useful in the determination of products texture profile.

  8. Dynamic texture perception and oral processing of semi-solid food gels: Part 1: Comparison between QDA, progressive profiling and TDS

    NARCIS (Netherlands)

    Devezeaux de Lavergne, M.S.M.; Delft, van J.M.; Velde, van de F.; Boekel, van M.A.J.S.; Stieger, M.A.

    2015-01-01

    Texture perception of food is a dynamic phenomenon depending on food properties and oral processing. Several sensory techniques enable to measure texture perception over time. The aim of this study was to compare quantitative descriptive analysis (QDA), temporal dominance of sensation (TDS) and

  9. Geometrical conditions at the quantitative neutronographic texture analysis

    International Nuclear Information System (INIS)

    Tobisch, J.; Kleinstueck, K.

    1975-10-01

    The beam geometry for measuring quantitative pole figures by a neutronographic texture diffractometer is explained for transmission and reflection arrangement of spherical samples and sheets. For given dimensions of counter aperture the maximum possible cross sections of the incident beam are calculated as a function of sample dimensions and the Bragg angle theta. Methods for the calculation of absorption factors and volume correction are given. Under special conditions advantages result in the transmission case for sample motion into the direction +α. (author)

  10. Silicate glasses corrosion. Texture analysis of the corrosion layer

    International Nuclear Information System (INIS)

    Portal, Sabine

    2001-01-01

    We have studied the kinetic and the texture evolution of the corroded layer that forms on glass surfaces exposed to acidic solutions. The corroded layer is depleted in alkali cations and is produced by an ion exchange mechanism. It is porous and shows a lower refractive index than the one of the bulk glass. Spectroscopic ellipsometry allows determining the thickness of the layer and its refractive index. Several other techniques have been developed for characterizing the corrosion behaviour of glass surfaces: porosity is thus investigated by adsorption-desorption of nitrogen; the thickness and the composition of the layer are studied by secondary ion mass spectroscopy (S.I.M.S.); sodium concentration in the solution has been analyzed by atomic absorption. This study shows the importance of leaching conditions and glass preparation. The type of drying employed is susceptible to modify the texture and the structure of the layer. The layers produced in the early stages of the leaching process are not easily detectable. The different results lead however to the same conclusion: after a strong increase of porosity, a densification of the layer is observed with increasing time. The evolution of the layer texture could therefore modify the kinetic of the glass corrosion. (author) [fr

  11. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer.

    Science.gov (United States)

    Bates, Anthony; Miles, Kenneth

    2017-12-01

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at prostate cancer. • Prostate transition zone (TZ) MR texture analysis may assist in prostate cancer detection. • Abnormal transition zone PSMA expression correlates with altered texture on T2-weighted MR. • TZ with abnormal PSMA expression demonstrates significantly reduced MI, SD and MPP.

  12. Texture, residual stress and structural analysis of thin films using a combined X-ray analysis

    International Nuclear Information System (INIS)

    Lutterotti, L.; Chateigner, D.; Ferrari, S.; Ricote, J.

    2004-01-01

    Advanced thin films for today's industrial and research needs require highly specialized methodologies for a successful quantitative characterization. In particular, in the case of multilayer and/or unknown phases a global approach is necessary to obtain some or all the required information. A full approach has been developed integrating novel texture and residual stress methodologies with the Rietveld method (Acta Cryst. 22 (1967) 151) (for crystal structure analysis) and it has been coupled with the reflectivity analysis. The complete analysis can be done at once and offers several benefits: the thicknesses obtained from reflectivity can be used to correct the diffraction spectra, the phase analysis help to identify the layers and to determine the electron density profile for reflectivity; quantitative texture is needed for quantitative phase and residual stress analyses; crystal structure determination benefits of the previous. To achieve this result, it was necessary to develop some new methods, especially for texture and residual stresses. So it was possible to integrate them in the Rietveld, full profile fitting of the patterns. The measurement of these spectra required a special reflectometer/diffractometer that combines a thin parallel beam (for reflectivity) and a texture/stress goniometer with a curved large position sensitive detector. This new diffraction/reflectivity X-ray machine has been used to test the combined approach. Several spectra and the reflectivity patterns have been collected at different tilting angles and processed at once by the special software incorporating the aforementioned methodologies. Some analysis examples will be given to show the possibilities offered by the method

  13. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M. [Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States); University of Health Sciences, Medical Informatics and Technology, 6060 Hall (Austria); AO Development Institute, 7270 Davos Platz (Switzerland); Medical University Innsbruck, 6020 Innsbruck (Austria); Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States)

    2009-11-15

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R{sup 2

  14. UAV Remote Sensing for Urban Vegetation Mapping Using Random Forest and Texture Analysis

    Directory of Open Access Journals (Sweden)

    Quanlong Feng

    2015-01-01

    Full Text Available Unmanned aerial vehicle (UAV remote sensing has great potential for vegetation mapping in complex urban landscapes due to the ultra-high resolution imagery acquired at low altitudes. Because of payload capacity restrictions, off-the-shelf digital cameras are widely used on medium and small sized UAVs. The limitation of low spectral resolution in digital cameras for vegetation mapping can be reduced by incorporating texture features and robust classifiers. Random Forest has been widely used in satellite remote sensing applications, but its usage in UAV image classification has not been well documented. The objectives of this paper were to propose a hybrid method using Random Forest and texture analysis to accurately differentiate land covers of urban vegetated areas, and analyze how classification accuracy changes with texture window size. Six least correlated second-order texture measures were calculated at nine different window sizes and added to original Red-Green-Blue (RGB images as ancillary data. A Random Forest classifier consisting of 200 decision trees was used for classification in the spectral-textural feature space. Results indicated the following: (1 Random Forest outperformed traditional Maximum Likelihood classifier and showed similar performance to object-based image analysis in urban vegetation classification; (2 the inclusion of texture features improved classification accuracy significantly; (3 classification accuracy followed an inverted U relationship with texture window size. The results demonstrate that UAV provides an efficient and ideal platform for urban vegetation mapping. The hybrid method proposed in this paper shows good performance in differentiating urban vegetation mapping. The drawbacks of off-the-shelf digital cameras can be reduced by adopting Random Forest and texture analysis at the same time.

  15. Image sequence analysis using spatio-temporal texture

    International Nuclear Information System (INIS)

    Sengupta, S.K.; Clark, G.A.; Barnes, F.L.; Schaich, P.C.

    1994-01-01

    The authors have developed and coded an algorithm for motion pattern classification based on spatio-temporal texture. The algorithm has been implemented and tested for the detection of wakes in simulated data with a relatively low signal-to-noise ratio (0.7 dB). Using a open-quote hold one out close-quote method, a detection probability of 100% with a 0% false alarm rate has been achieved on the limited number of samples (47 in each category) tested. The actual detection can be displayed in the form of a movie that can effectively show the submarine tracks based on the detected wake locations

  16. Identification of components of fibroadenoma in cytology preparations using texture analysis: a morphometric study.

    Science.gov (United States)

    Singh, S; Gupta, R

    2012-06-01

    To evaluate the utility of image analysis using textural parameters obtained from a co-occurrence matrix in differentiating the three components of fibroadenoma of the breast, in fine needle aspirate smears. Sixty cases of histologically proven fibroadenoma were included in this study. Of these, 40 cases were used as a training set and 20 cases were taken as a test set for the discriminant analysis. Digital images were acquired from cytological preparations of all the cases and three components of fibroadenoma (namely, monolayered cell clusters, stromal fragments and background with bare nuclei) were selected for image analysis. A co-occurrence matrix was generated and a texture parameter vector (sum mean, energy, entropy, contrast, cluster tendency and homogeneity) was calculated for each pixel. The percentage of pixels correctly classified to a component of fibroadenoma on discriminant analysis was noted. The textural parameters, when considered in isolation, showed considerable overlap in their values of the three cytological components of fibroadenoma. However, the stepwise discriminant analysis revealed that all six textural parameters contributed significantly to the discriminant functions. Discriminant analysis using all the six parameters showed that the numbers of pixels correctly classified in training and tests sets were 96.7% and 93.0%, respectively. Textural analysis using a co-occurrence matrix appears to be useful in differentiating the three cytological components of fibroadenoma. These results could further be utilized in developing algorithms for image segmentation and automated diagnosis, but need to be confirmed in further studies. © 2011 Blackwell Publishing Ltd.

  17. Efficient iris texture analysis method based on Gabor ordinal measures

    Science.gov (United States)

    Tajouri, Imen; Aydi, Walid; Ghorbel, Ahmed; Masmoudi, Nouri

    2017-07-01

    With the remarkably increasing interest directed to the security dimension, the iris recognition process is considered to stand as one of the most versatile technique critically useful for the biometric identification and authentication process. This is mainly due to every individual's unique iris texture. A modestly conceived efficient approach relevant to the feature extraction process is proposed. In the first place, iris zigzag "collarette" is extracted from the rest of the image by means of the circular Hough transform, as it includes the most significant regions lying in the iris texture. In the second place, the linear Hough transform is used for the eyelids' detection purpose while the median filter is applied for the eyelashes' removal. Then, a special technique combining the richness of Gabor features and the compactness of ordinal measures is implemented for the feature extraction process, so that a discriminative feature representation for every individual can be achieved. Subsequently, the modified Hamming distance is used for the matching process. Indeed, the advanced procedure turns out to be reliable, as compared to some of the state-of-the-art approaches, with a recognition rate of 99.98%, 98.12%, and 95.02% on CASIAV1.0, CASIAV3.0, and IIT Delhi V1 iris databases, respectively.

  18. Comparation of instrumental and sensory methods in fermented milk beverages texture quality analysis

    Directory of Open Access Journals (Sweden)

    Jovica Hardi

    2001-04-01

    Full Text Available The texture of the curd of fermented dairy products is one of the primary factors of their overall quality. The flow properties of fermented dairy products have characteristic of thixotropic (pseudoplastic type of liquids. At the same time, these products are viscoelastic systems, i.e. they are capable of texture renewal after applied deformation. Complex analysis of some of the properties is essentional for the system description . The aim of the present work was to completely describe the texture of fermented milk beverages . Three basic parameters were taken into consideration: structure, hardness (consistency and stability of the curd. The description model of these three parameters was applied on the basis of the experimental results obteined. Results obtained by present model were compared with the results of sensory analysis. Influence of milk fat content and skimmed milk powder addition on acidophilus milk texture quality was also examined using this model. It was shawn that, by using this model – on the basis of instrumental and sensory analyses, a complete and objective determination of texture quality of the fermented milk beverages can be obtained. High degree of correlation between instrumental and sensory results (r =0.8975 is obtained results of this work indicated that both factors (milk fat content and skimmed milk powder addition had an influence on texture quality. Samples with higher milk fat content had a better texture properties in comparsion with low fat content samples. Texture of all examined samples was improved by increasing skimmed milk powder content. Optimal amounts of skimmed milk powder addition with regard to milk fat content, in milk, is determined using the proposed model.

  19. Fractal Dimension Analysis of Texture Formation of Whey Protein-Based Foods

    Directory of Open Access Journals (Sweden)

    Robi Andoyo

    2018-01-01

    Full Text Available Whey protein in the form of isolate or concentrate is widely used in food industries due to its functionality to form gel under certain condition and its nutritive value. Controlling or manipulating the formation of gel aggregates is used often to evaluate food texture. Many researchers made use of fractal analysis that provides the quantitative data (i.e., fractal dimension for fundamentally and rationally analyzing and designing whey protein-based food texture. This quantitative analysis is also done to better understand how the texture of whey protein-based food is formed. Two methods for fractal analysis were discussed in this review: image analysis (microscopy and rheology. These methods, however, have several limitations which greatly affect the accuracy of both fractal dimension values and types of aggregation obtained. This review therefore also discussed problem encountered and ways to reduce the potential errors during fractal analysis of each method.

  20. Gastric cancer: texture analysis from multidetector computed tomography as a potential preoperative prognostic biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Giganti, Francesco; Salerno, Annalaura; Marra, Paolo; Esposito, Antonio; Del Maschio, Alessandro; De Cobelli, Francesco [Department of Radiology and Centre for Experimental Imaging San Raffaele Scientific Institute, Milan (Italy); San Raffaele Vita-Salute University, Milan (Italy); Antunes, Sofia [San Raffaele Scientific Institute, Centre for Experimental Imaging, Milan (Italy); Ambrosi, Alessandro [San Raffaele Vita-Salute University, Milan (Italy); Nicoletti, Roberto [Department of Radiology and Centre for Experimental Imaging San Raffaele Scientific Institute, Milan (Italy); Orsenigo, Elena [San Raffaele Scientific Institute, Department of Surgery, Milan (Italy); Chiari, Damiano; Staudacher, Carlo [San Raffaele Vita-Salute University, Milan (Italy); San Raffaele Scientific Institute, Department of Surgery, Milan (Italy); Albarello, Luca [San Raffaele Scientific Institute, Pathology Unit, Milan (Italy)

    2017-05-15

    To investigate the association between preoperative texture analysis from multidetector computed tomography (MDCT) and overall survival in patients with gastric cancer. Institutional review board approval and informed consent were obtained. Fifty-six patients with biopsy-proved gastric cancer were examined by MDCT and treated with surgery. Image features from texture analysis were quantified, with and without filters for fine to coarse textures. The association with survival time was assessed using Kaplan-Meier and Cox analysis. The following parameters were significantly associated with a negative prognosis, according to different thresholds: energy [no filter] - Logarithm of relative risk (Log RR): 3.25; p = 0.046; entropy [no filter] (Log RR: 5.96; p = 0.002); entropy [filter 1.5] (Log RR: 3.54; p = 0.027); maximum Hounsfield unit value [filter 1.5] (Log RR: 3.44; p = 0.027); skewness [filter 2] (Log RR: 5.83; p = 0.004); root mean square [filter 1] (Log RR: - 2.66; p = 0.024) and mean absolute deviation [filter 2] (Log RR: - 4.22; p = 0.007). Texture analysis could increase the performance of a multivariate prognostic model for risk stratification in gastric cancer. Further evaluations are warranted to clarify the clinical role of texture analysis from MDCT. (orig.)

  1. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    International Nuclear Information System (INIS)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M.

    2009-01-01

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R 2 =0.61 (MF

  2. Three-dimensional textural analysis of brain images reveals distributed grey-matter abnormalities in schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Ganeshan, Balaji [University of Sussex, Falmer, Clinical Imaging Sciences Centre, Brighton and Sussex Medical School, Brighton (United Kingdom); University of Sussex, Falmer, Department of Engineering and Design, Brighton (United Kingdom); Miles, Kenneth A.; Critchley, Hugo D. [University of Sussex, Falmer, Clinical Imaging Sciences Centre, Brighton and Sussex Medical School, Brighton (United Kingdom); Young, Rupert C.D.; Chatwin, Christopher R. [University of Sussex, Falmer, Department of Engineering and Design, Brighton (United Kingdom); Gurling, Hugh M.D. [University College London, Department of Mental Health Sciences, London (United Kingdom)

    2010-04-15

    Three-dimensional (3-D) selective- and relative-scale texture analysis (TA) was applied to structural magnetic resonance (MR) brain images to quantify the presence of grey-matter (GM) and white-matter (WM) textural abnormalities associated with schizophrenia. Brain TA comprised volume filtration using the Laplacian of Gaussian filter to highlight fine, medium and coarse textures within GM and WM, followed by texture quantification. Relative TA (e.g. ratio of fine to medium) was also computed. T1-weighted MR whole-brain images from 32 participants with diagnosis of schizophrenia (n = 10) and healthy controls (n = 22) were examined. Five patients possessed marker alleles (SZ8) associated with schizophrenia on chromosome 8 in the pericentriolar material 1 gene while the remaining five had not inherited any of the alleles (SZ0). Filtered fine GM texture (mean grey-level intensity; MGI) most significantly differentiated schizophrenic patients from controls (P = 0.0058; area under the receiver-operating characteristic curve = 0.809, sensitivity = 90%, specificity = 70%). WM measurements did not distinguish the two groups. Filtered GM and WM textures (MGI) correlated with total GM and WM volume respectively. Medium-to-coarse GM entropy distinguished SZ0 from controls (P = 0.0069) while measures from SZ8 were intermediate between the two. 3-D TA of brain MR enables detection of subtle distributed morphological features associated with schizophrenia, determined partly by susceptibility genes. (orig.)

  3. Three-dimensional textural analysis of brain images reveals distributed grey-matter abnormalities in schizophrenia

    International Nuclear Information System (INIS)

    Ganeshan, Balaji; Miles, Kenneth A.; Critchley, Hugo D.; Young, Rupert C.D.; Chatwin, Christopher R.; Gurling, Hugh M.D.

    2010-01-01

    Three-dimensional (3-D) selective- and relative-scale texture analysis (TA) was applied to structural magnetic resonance (MR) brain images to quantify the presence of grey-matter (GM) and white-matter (WM) textural abnormalities associated with schizophrenia. Brain TA comprised volume filtration using the Laplacian of Gaussian filter to highlight fine, medium and coarse textures within GM and WM, followed by texture quantification. Relative TA (e.g. ratio of fine to medium) was also computed. T1-weighted MR whole-brain images from 32 participants with diagnosis of schizophrenia (n = 10) and healthy controls (n = 22) were examined. Five patients possessed marker alleles (SZ8) associated with schizophrenia on chromosome 8 in the pericentriolar material 1 gene while the remaining five had not inherited any of the alleles (SZ0). Filtered fine GM texture (mean grey-level intensity; MGI) most significantly differentiated schizophrenic patients from controls (P = 0.0058; area under the receiver-operating characteristic curve = 0.809, sensitivity = 90%, specificity = 70%). WM measurements did not distinguish the two groups. Filtered GM and WM textures (MGI) correlated with total GM and WM volume respectively. Medium-to-coarse GM entropy distinguished SZ0 from controls (P = 0.0069) while measures from SZ8 were intermediate between the two. 3-D TA of brain MR enables detection of subtle distributed morphological features associated with schizophrenia, determined partly by susceptibility genes. (orig.)

  4. Texture analysis for the assessment of structural changes in parotid glands induced by radiotherapy

    International Nuclear Information System (INIS)

    Scalco, Elisa; Fiorino, Claudio; Cattaneo, Giovanni Mauro; Sanguineti, Giuseppe; Rizzo, Giovanna

    2013-01-01

    Background and purpose: During radiotherapy (RT) for head-and-neck cancer, parotid glands undergo significant anatomic, functional and structural changes which could characterize pre-clinical signs of an increased risk of xerostomia. Texture analysis is proposed to assess structural changes of parotids induced by RT, and to investigate whether early variations of textural parameters (such as mean intensity and fractal dimension) can predict parotid shrinkage at the end of treatment. Material and methods: Textural parameters and volumes of 42 parotids from 21 patients treated with intensity-modulated RT for nasopharyngeal cancer were extracted from CT images. To individuate which parameters changed during RT, a Wilcoxon signed-rank test between textural indices (first and second RT week; first and last RT week) was performed. Discriminant analysis was applied to variations of these parameters in the first two weeks of RT to assess their power in predicting parotid shrinkage at the end of RT. Results: A significant decrease in mean intensity (1.7 HU and 3.8 HU after the second and last weeks, respectively) and fractal dimension (0.016 and 0.021) was found. Discriminant analysis, based on volume and fractal dimension, was able to predict the final parotid shrinkage (accuracy of 71.4%). Conclusion: Textural features could be used in combination with volume to characterize structural modifications on parotid glands and to predict parotid shrinkage at the end of RT

  5. Adaptive multiresolution Hermite-Binomial filters for image edge and texture analysis

    NARCIS (Netherlands)

    Gu, Y.H.; Katsaggelos, A.K.

    1994-01-01

    A new multiresolution image analysis approach using adaptive Hermite-Binomial filters is presented in this paper. According to the local image structural and textural properties, the analysis filter kernels are made adaptive both in their scales and orders. Applications of such an adaptive filtering

  6. A standardised protocol for texture feature analysis of endoscopic images in gynaecological cancer

    Directory of Open Access Journals (Sweden)

    Pattichis Marios S

    2007-11-01

    Full Text Available Abstract Background In the development of tissue classification methods, classifiers rely on significant differences between texture features extracted from normal and abnormal regions. Yet, significant differences can arise due to variations in the image acquisition method. For endoscopic imaging of the endometrium, we propose a standardized image acquisition protocol to eliminate significant statistical differences due to variations in: (i the distance from the tissue (panoramic vs close up, (ii difference in viewing angles and (iii color correction. Methods We investigate texture feature variability for a variety of targets encountered in clinical endoscopy. All images were captured at clinically optimum illumination and focus using 720 × 576 pixels and 24 bits color for: (i a variety of testing targets from a color palette with a known color distribution, (ii different viewing angles, (iv two different distances from a calf endometrial and from a chicken cavity. Also, human images from the endometrium were captured and analysed. For texture feature analysis, three different sets were considered: (i Statistical Features (SF, (ii Spatial Gray Level Dependence Matrices (SGLDM, and (iii Gray Level Difference Statistics (GLDS. All images were gamma corrected and the extracted texture feature values were compared against the texture feature values extracted from the uncorrected images. Statistical tests were applied to compare images from different viewing conditions so as to determine any significant differences. Results For the proposed acquisition procedure, results indicate that there is no significant difference in texture features between the panoramic and close up views and between angles. For a calibrated target image, gamma correction provided an acquired image that was a significantly better approximation to the original target image. In turn, this implies that the texture features extracted from the corrected images provided for better

  7. Diagnosis and prognosis of Ostheoarthritis by texture analysis using sparse linear models

    DEFF Research Database (Denmark)

    Marques, Joselene; Clemmensen, Line Katrine Harder; Dam, Erik

    We present a texture analysis methodology that combines uncommitted machine-learning techniques and sparse feature transformation methods in a fully automatic framework. We compare the performances of a partial least squares (PLS) forward feature selection strategy to a hard threshold sparse PLS...... algorithm and a sparse linear discriminant model. The texture analysis framework was applied to diagnosis of knee osteoarthritis (OA) and prognosis of cartilage loss. For this investigation, a generic texture feature bank was extracted from magnetic resonance images of tibial knee bone. The features were...... used as input to the sparse algorithms, which dened the best features to retain in the model. To cope with the limited number of samples, the data was evaluated using 10 fold cross validation (CV). The diagnosis evaluation using sparse PLS reached a generalization area-under-the-ROC curve (AUC) of 0...

  8. Differentiating pheochromocytoma from lipid-poor adrenocortical adenoma by CT texture analysis: feasibility study.

    Science.gov (United States)

    Zhang, Gu-Mu-Yang; Shi, Bing; Sun, Hao; Jin, Zheng-Yu; Xue, Hua-Dan

    2017-09-01

    To investigate the feasibility of using CT texture analysis (CTTA) to differentiate pheochromocytoma from lipid-poor adrenocortical adenoma (lp-ACA). Ninety-eight pheochromocytomas and 66 lp-ACAs were included in this retrospective study. CTTA was performed on unenhanced and enhanced images. Receiver operating characteristic (ROC) analysis was performed, and the area under the ROC curve (AUC) was calculated for texture parameters that were significantly different for the objective. Diagnostic accuracies were evaluated using the cutoff values of texture parameters with the highest AUCs. Compared to lp-ACAs, pheochromocytomas had significantly higher mean gray-level intensity (Mean), entropy, and mean of positive pixels (MPP), but lower skewness and kurtosis on unenhanced images (P feasible to use CTTA to differentiate pheochromocytoma from lp-ACA.

  9. Medullar fat influences texture analysis of trabecular microarchitecture on X-ray radiographs

    International Nuclear Information System (INIS)

    Chappard, Daniel; Pascaretti-Grizon, Florence; Gallois, Yves; Mercier, Philippe; Basle, Michel F.; Audran, Maurice

    2006-01-01

    Alteration of trabecular architecture is a predictor of fracture risk in osteoporosis. Until now, microarchitecture analysis is difficult to evaluate in routine clinical practice for osteoporosis. Texture analysis on X-ray images has been advocated to be a suitable method to assess microarchitecture in bone diseases. The X-ray acquisition conditions have been often taken into consideration; however, the influence of anatomical conditions on texture parameters has received little interest. Because fat is a well-known problem with computed tomography and densitometry, we have designed a cadaver study to compare the influence of marrow lipids on numerous texture parameters. Twenty-one human distal radii were obtained, radiographed, and analyzed using a software that measures: heterogeneity, skeletonized parameters, run-lengths and fractal dimensions. Texture parameters were measured before, and after an extensive delipidation period lasting 3 weeks. Quality of the radiographs was improved after defatting. Delipidation had a very significant effect on measurements: afterwards defatting, the images were less blurred, and a better delineation of trabeculae and marrow cavities was obtained. This provoked an increase of parameters based on the grey level distribution but had no influence on parameters describing the reticulated honeycomb microarchitecture of the trabeculae (i.e., fractal dimension). Some parameters appeared anisotropy-sensitive, due to the different constitution and size of the trabeculae. The fat content of bone marrow induces noise that can modify some texture parameters. One should take into account the fat content of the marrow when using texture analysis to compare patients with osteoporosis due to various etiologies

  10. Investigation of magnetic resonance imaging texture analysis as an aid tool for characterization of refractory epilepsies

    Directory of Open Access Journals (Sweden)

    Mauricio Martins Baldissin

    2013-12-01

    Full Text Available Refractory epilepsies are syndromes for which therapies that employ two or more antiepileptic drugs, separately or in association, do not result in control of crisis. Patients may present focal cortical dysplasia or diffuse dysplasia and/or hippocampal atrophic alterations that may not be detectable by a simple visual analysis in magnetic resonance imaging. The aim of this study was to evaluate MRI texture in regions of interest located in the hippocampi, limbic association cortex and prefrontal cortex of 20 patients with refractory epilepsy and to compare them with the same areas in 20 healthy individuals, in order to find out if the texture parameters could be related to the presence of the disease. Of the 11 texture parameters calculated, three indicated the existence of statistically significant differences between the studied groups. Such findings suggest the possibility of this technique contributing to studies of refractory epilepsies.

  11. Digitisation of films and texture analysis for digital classification of pulmonary opacities

    International Nuclear Information System (INIS)

    Desaga, J.F.; Dengler, J.; Wolf, T.; Engelmann, U.; Scheppelmann, D.; Meinzer, H.P.

    1988-01-01

    The study aimed at evaluating the effect of different methods of digitisation of radiographic films on the digital classification of pulmonary opacities. Test sets from the standard of the International Labour Office (ILO) Classification of Radiographs of Pneumoconiosis were prepared by film digitsation using a scanning microdensitometer or a video digitiser based on a personal computer equipped with a real time digitiser board and a vidicon or a Charge Coupled Device (CCD) camera. Seven different algorithms were used for texture analysis resulting in 16 texture parameters for each region. All methods used for texture analysis were independent of the mean grey value level and the size of the image analysed. Classification was performed by discriminant analysis using the classes from the ILO classification. A hit ratio of at least 85% was achieved for a digitisation by scanner digitisation or the vidicon, while the corresponding results of the CCD camera were significantly less good. Classification by texture analysis of opacities of chest X-rays of pneumoconiosis digitised by a personal computer based video digitiser and a vidicon are of equal quality compared to digitisation by a scanning microdensitometer. Correct classification of 90% was achieved via the described statistical approach. (orig.) [de

  12. Application of CT texture analysis in predicting histopathological characteristics of gastric cancers

    International Nuclear Information System (INIS)

    Liu, Shunli; Liu, Song; Ji, Changfeng; Zheng, Huanhuan; Pan, Xia; Zhang, Yujuan; He, Jian; Zhou, Zhengyang; Guan, Wenxian; Chen, Ling; Guan, Yue; Li, Weifeng; Ge, Yun

    2017-01-01

    To explore the application of computed tomography (CT) texture analysis in predicting histopathological features of gastric cancers. Preoperative contrast-enhanced CT images and postoperative histopathological features of 107 patients (82 men, 25 women) with gastric cancers were retrospectively reviewed. CT texture analysis generated: (1) mean attenuation, (2) standard deviation, (3) max frequency, (4) mode, (5) minimum attenuation, (6) maximum attenuation, (7) the fifth, 10th, 25th, 50th, 75th and 90th percentiles, and (8) entropy. Correlations between CT texture parameters and histopathological features were analysed. Mean attenuation, maximum attenuation, all percentiles and mode derived from portal venous CT images correlated significantly with differentiation degree and Lauren classification of gastric cancers (r, -0.231 ∝-0.324, 0.228 ∝ 0.321, respectively). Standard deviation and entropy derived from arterial CT images also correlated significantly with Lauren classification of gastric cancers (r = -0.265, -0.222, respectively). In arterial phase analysis, standard deviation and entropy were significantly lower in gastric cancers with than those without vascular invasion; however, minimum attenuation was significantly higher in gastric cancers with than those without vascular invasion. CT texture analysis held great potential in predicting differentiation degree, Lauren classification and vascular invasion status of gastric cancers. (orig.)

  13. Application of CT texture analysis in predicting histopathological characteristics of gastric cancers

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shunli; Liu, Song; Ji, Changfeng; Zheng, Huanhuan; Pan, Xia; Zhang, Yujuan; He, Jian; Zhou, Zhengyang [The Affiliated Hospital of Nanjing University Medical School, Department of Radiology, Nanjing Drum Tower Hospital, Nanjing, Jiangsu Province (China); Guan, Wenxian [The Affiliated Hospital of Nanjing University Medical School, Department of Gastrointestinal Surgery, Nanjing Drum Tower Hospital, Nanjing (China); Chen, Ling [The Affiliated Hospital of Nanjing University Medical School, Department of Pathology, Nanjing Drum Tower Hospital, Nanjing, Jiangsu Province (China); Guan, Yue; Li, Weifeng; Ge, Yun [Nanjing University, School of Electronic Science and Engineering, Nanjing (China)

    2017-12-15

    To explore the application of computed tomography (CT) texture analysis in predicting histopathological features of gastric cancers. Preoperative contrast-enhanced CT images and postoperative histopathological features of 107 patients (82 men, 25 women) with gastric cancers were retrospectively reviewed. CT texture analysis generated: (1) mean attenuation, (2) standard deviation, (3) max frequency, (4) mode, (5) minimum attenuation, (6) maximum attenuation, (7) the fifth, 10th, 25th, 50th, 75th and 90th percentiles, and (8) entropy. Correlations between CT texture parameters and histopathological features were analysed. Mean attenuation, maximum attenuation, all percentiles and mode derived from portal venous CT images correlated significantly with differentiation degree and Lauren classification of gastric cancers (r, -0.231 ∝-0.324, 0.228 ∝ 0.321, respectively). Standard deviation and entropy derived from arterial CT images also correlated significantly with Lauren classification of gastric cancers (r = -0.265, -0.222, respectively). In arterial phase analysis, standard deviation and entropy were significantly lower in gastric cancers with than those without vascular invasion; however, minimum attenuation was significantly higher in gastric cancers with than those without vascular invasion. CT texture analysis held great potential in predicting differentiation degree, Lauren classification and vascular invasion status of gastric cancers. (orig.)

  14. Characterising the disintegration properties of tablets in opaque media using texture analysis

    OpenAIRE

    Scheuerle, Rebekah L.; Gerrard, Stephen E.; Kendall, Richard A.; Tuleu, Catherine; Slater, Nigel K.H.; Mahbubani, Krishnaa T.

    2015-01-01

    Tablet disintegration characterisation is used in pharmaceutical research, development, and quality control. Standard methods used to characterise tablet disintegration are often dependent on visual observation in measurement of disintegration times. This presents a challenge for disintegration studies of tablets in opaque, physiologically relevant media that could be useful for tablet formulation optimisation. In this study is explored an application of texture analysis disintegration testin...

  15. Characterization of microcirculation in multiple sclerosis lesions by dynamic texture parameter analysis (DTPA.

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar Verma

    Full Text Available OBJECTIVE: Texture analysis is an alternative method to quantitatively assess MR-images. In this study, we introduce dynamic texture parameter analysis (DTPA, a novel technique to investigate the temporal evolution of texture parameters using dynamic susceptibility contrast enhanced (DSCE imaging. Here, we aim to introduce the method and its application on enhancing lesions (EL, non-enhancing lesions (NEL and normal appearing white matter (NAWM in multiple sclerosis (MS. METHODS: We investigated 18 patients with MS and clinical isolated syndrome (CIS, according to the 2010 McDonald's criteria using DSCE imaging at different field strengths (1.5 and 3 Tesla. Tissues of interest (TOIs were defined within 27 EL, 29 NEL and 37 NAWM areas after normalization and eight histogram-based texture parameter maps (TPMs were computed. TPMs quantify the heterogeneity of the TOI. For every TOI, the average, variance, skewness, kurtosis and variance-of-the-variance statistical parameters were calculated. These TOI parameters were further analyzed using one-way ANOVA followed by multiple Wilcoxon sum rank testing corrected for multiple comparisons. RESULTS: Tissue- and time-dependent differences were observed in the dynamics of computed texture parameters. Sixteen parameters discriminated between EL, NEL and NAWM (pAVG = 0.0005. Significant differences in the DTPA texture maps were found during inflow (52 parameters, outflow (40 parameters and reperfusion (62 parameters. The strongest discriminators among the TPMs were observed in the variance-related parameters, while skewness and kurtosis TPMs were in general less sensitive to detect differences between the tissues. CONCLUSION: DTPA of DSCE image time series revealed characteristic time responses for ELs, NELs and NAWM. This may be further used for a refined quantitative grading of MS lesions during their evolution from acute to chronic state. DTPA discriminates lesions beyond features of enhancement or T2

  16. Breast Cancer Risk Estimation Using Parenchymal Texture Analysis in Digital Breast Tomosynthesis

    International Nuclear Information System (INIS)

    Ikejimba, Lynda C.; Kontos, Despina; Maidment, Andrew D. A.

    2010-01-01

    Mammographic parenchymal texture has been shown to correlate with genetic markers of developing breast cancer. Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique in which tomographic images of the breast are reconstructed from multiple source projections acquired at different angles of the x-ray tube. Compared to digital mammography (DM), DBT eliminates breast tissue overlap, offering superior parenchymal tissue visualization. We hypothesize that texture analysis in DBT could potentially provide a better assessment of parenchymal texture and ultimately result in more accurate assessment of breast cancer risk. As a first step towards validating this hypothesis, we investigated the association between DBT parenchymal texture and breast percent density (PD), a known breast cancer risk factor, and compared it to DM. Bilateral DBT and DM images from 71 women participating in a breast cancer screening trial were analyzed. Filtered-backprojection was used to reconstruct DBT tomographic planes in 1 mm increments with 0.22 mm in-plane resolution. Corresponding DM images were acquired at 0.1 mm pixel resolution. Retroareolar regions of interest (ROIs) equivalent to 2.5 cm 3 were segmented from the DBT images and corresponding 2.5 cm 2 ROIs were segmented from the DM images. Breast PD was mammographically estimated using the Cumulus scale. Overall, DBT texture features demonstrated a stronger correlation than DM to PD. The Pearson correlation coefficients for DBT were r = 0.40 (p 2 = 0.39) compared to DM (R 2 = 0.33). We attribute these observations to the superior parenchymal tissue visualization in DBT. Our study is the first to perform DBT texture analysis in a screening population of women, showing that DBT could potentially provide better breast cancer risk assessment in the future.

  17. Application of Texture Analysis to Study Small Vessel Disease and Blood–Brain Barrier Integrity

    Directory of Open Access Journals (Sweden)

    Maria del C. Valdés Hernández

    2017-07-01

    Full Text Available ObjectivesWe evaluate the alternative use of texture analysis for evaluating the role of blood–brain barrier (BBB in small vessel disease (SVD.MethodsWe used brain magnetic resonance imaging from 204 stroke patients, acquired before and 20 min after intravenous gadolinium administration. We segmented tissues, white matter hyperintensities (WMH and applied validated visual scores. We measured textural features in all tissues pre- and post-contrast and used ANCOVA to evaluate the effect of SVD indicators on the pre-/post-contrast change, Kruskal–Wallis for significance between patient groups and linear mixed models for pre-/post-contrast variations in cerebrospinal fluid (CSF with Fazekas scores.ResultsTextural “homogeneity” increase in normal tissues with higher presence of SVD indicators was consistently more overt than in abnormal tissues. Textural “homogeneity” increased with age, basal ganglia perivascular spaces scores (p < 0.01 and SVD scores (p < 0.05 and was significantly higher in hypertensive patients (p < 0.002 and lacunar stroke (p = 0.04. Hypertension (74% patients, WMH load (median = 1.5 ± 1.6% of intracranial volume, and age (mean = 65.6 years, SD = 11.3 predicted the pre/post-contrast change in normal white matter, WMH, and index stroke lesion. CSF signal increased with increasing SVD post-contrast.ConclusionA consistent general pattern of increasing textural “homogeneity” with increasing SVD and post-contrast change in CSF with increasing WMH suggest that texture analysis may be useful for the study of BBB integrity.

  18. Quantitative Ultrasound Using Texture Analysis of Myofascial Pain Syndrome in the Trapezius.

    Science.gov (United States)

    Kumbhare, Dinesh A; Ahmed, Sara; Behr, Michael G; Noseworthy, Michael D

    2018-01-01

    Objective-The objective of this study is to assess the discriminative ability of textural analyses to assist in the differentiation of the myofascial trigger point (MTrP) region from normal regions of skeletal muscle. Also, to measure the ability to reliably differentiate between three clinically relevant groups: healthy asymptomatic, latent MTrPs, and active MTrP. Methods-18 and 19 patients were identified with having active and latent MTrPs in the trapezius muscle, respectively. We included 24 healthy volunteers. Images were obtained by research personnel, who were blinded with respect to the clinical status of the study participant. Histograms provided first-order parameters associated with image grayscale. Haralick, Galloway, and histogram-related features were used in texture analysis. Blob analysis was conducted on the regions of interest (ROIs). Principal component analysis (PCA) was performed followed by multivariate analysis of variance (MANOVA) to determine the statistical significance of the features. Results-92 texture features were analyzed for factorability using Bartlett's test of sphericity, which was significant. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.94. PCA demonstrated rotated eigenvalues of the first eight components (each comprised of multiple texture features) explained 94.92% of the cumulative variance in the ultrasound image characteristics. The 24 features identified by PCA were included in the MANOVA as dependent variables, and the presence of a latent or active MTrP or healthy muscle were independent variables. Conclusion-Texture analysis techniques can discriminate between the three clinically relevant groups.

  19. Transformations in destination texture

    DEFF Research Database (Denmark)

    Gyimóthy, Szilvia

    2018-01-01

    This article takes heterogeographical approaches to understand Bollywood-induced destination transformations in Switzerland. Positioned within the theoretical field of mediatized mobility, the study contextualizes Bollywood-induced tourism in Europe the concept of texture. Textural analysis (base...

  20. Relating instrumental texture, determined relating instrumental texture, determined attachments, to sensory analysis of rainbow trout, Oncorhynchus mykiss, fillets

    Science.gov (United States)

    Texture is one of the most important quality attributes of fish fillets, and accurate assessment of variation in this attribute, as affected by storage and handling, is critical in providing consistent quality product. Trout fillets received 4 treatments: 3-d refrigeration (R3), 7-d refrigeration (R...

  1. Characterization of Enhancing MS Lesions by Dynamic Texture Parameter Analysis of Dynamic Susceptibility Perfusion Imaging

    Directory of Open Access Journals (Sweden)

    Rajeev K. Verma

    2016-01-01

    Full Text Available Purpose. The purpose of this study was to investigate statistical differences with MR perfusion imaging features that reflect the dynamics of Gadolinium-uptake in MS lesions using dynamic texture parameter analysis (DTPA. Methods. We investigated 51 MS lesions (25 enhancing, 26 nonenhancing lesions of 12 patients. Enhancing lesions (n=25 were prestratified into enhancing lesions with increased permeability (EL+; n=11 and enhancing lesions with subtle permeability (EL−; n=14. Histogram-based feature maps were computed from the raw DSC-image time series and the corresponding texture parameters were analyzed during the inflow, outflow, and reperfusion time intervals. Results. Significant differences (p<0.05 were found between EL+ and EL− and between EL+ and nonenhancing inactive lesions (NEL. Main effects between EL+ versus EL− and EL+ versus NEL were observed during reperfusion (mainly in mean and standard deviation (SD: EL+ versus EL− and EL+ versus NEL, while EL− and NEL differed only in their SD during outflow. Conclusion. DTPA allows grading enhancing MS lesions according to their perfusion characteristics. Texture parameters of EL− were similar to NEL, while EL+ differed significantly from EL− and NEL. Dynamic texture analysis may thus be further investigated as noninvasive endogenous marker of lesion formation and restoration.

  2. Quinoa Starch Characteristics and Their Correlations with the Texture Profile Analysis (TPA) of Cooked Quinoa.

    Science.gov (United States)

    Wu, Geyang; Morris, Craig F; Murphy, Kevin M

    2017-10-01

    Starch characteristics significantly influence the functionality and end-use quality of cereals and pseudo-cereals. This study examined the composition and properties of starch from 11 pure varieties and 2 commercial samples of quinoa in relationship to the texture of cooked quinoa. Nearly all starch properties and characteristics differed among these samples. Results showed that total starch content of seeds ranged from 53.2 to 75.1 g/100 g apparent amylose content ranged from 2.7% to 16.9%; total amylose ranged from 4.7% to 17.3%; and the degree of amylose-lipid complex ranged from 3.4% to 43.3%. Amylose leaching ranged from 31 mg/100 g starch in "Japanese Strain" to 862 mg/100 g starch in "49ALC." "Japanese Strain" starch also exhibited the highest water solubility (4.5%) and the lowest swelling power (17). α-Amylase activity in "1ESP," "Col.#6197," "Japanese Strain," "QQ63," "Yellow Commercial," and "Red Commercial" (0.03 to 0.09 CU) were significantly lower than the levels of the other quinoa samples (0.20 to 1.16 CU). Additionally, gel texture, thermal properties, and pasting properties of quinoa starches were investigated. Lastly, correlation analysis showed that the quinoa samples with higher amylose content tended to yield harder, stickier, more cohesive, more gummy, and more chewy texture after cooking. A higher degree of amylose-lipid complex and amylose leaching were associated with softer and less chewy cooked quinoa TPA texture. Higher starch enthalpy correlated with firmer, more adhesive, more cohesive, and chewier texture. In sum, starch plays a significant role in the texture of cooked quinoa. The research determined starch characteristics among a diverse set of pure quinoa varieties and commercial samples, and identified the relationships between starch properties and cooked quinoa texture. The results can help breeders and food manufacturers to understand better the relationships among quinoa starch characteristics, cooked quinoa texture, and

  3. Review of relationships between grey-tone co-occurrence, semivariance, and autocorrelation based image texture analysis approaches

    NARCIS (Netherlands)

    Sanden, van der J.J.; Hoekman, D.H.

    2005-01-01

    In the present paper we review relationships between commonly used statistical approaches to analysis of image texture. The approaches considered characterize image texture by means of the statistics of grey- tone co- occurrence contrast, grey- tone co- occurrence correlation, semivariance, and

  4. Texture analysis for mapping Tamarix parviflora using aerial photographs along the Cache Creek, California.

    Science.gov (United States)

    Ge, Shaokui; Carruthers, Raymond; Gong, Peng; Herrera, Angelica

    2006-03-01

    Natural color photographs were used to detect the coverage of saltcedar, Tamarix parviflora, along a 40 km portion of Cache Creek near Woodland, California. Historical aerial photographs from 2001 were retrospectively evaluated and compared with actual ground-based information to assess accuracy of the assessment process. The color aerial photos were sequentially digitized, georeferenced, classified using color and texture methods, and mosaiced into maps for field use. Eight types of ground cover (Tamarix, agricultural crops, roads, rocks, water bodies, evergreen trees, non-evergreen trees and shrubs (excluding Tamarix)) were selected from the digitized photos for separability analysis and supervised classification. Due to color similarities among the eight cover types, the average separability, based originally only on color, was very low. The separability was improved significantly through the inclusion of texture analysis. Six types of texture measures with various window sizes were evaluated. The best texture was used as an additional feature along with the color, for identifying Tamarix. A total of 29 color photographs were processed to detect Tamarix infestations using a combination of the original digital images and optimal texture features. It was found that the saltcedar covered a total of 3.96 km(2) (396 hectares) within the study area. For the accuracy assessment, 95 classified samples from the resulting map were checked in the field with a global position system (GPS) unit to verify Tamarix presence. The producer's accuracy was 77.89%. In addition, 157 independently located ground sites containing saltcedar were compared with the classified maps, producing a user's accuracy of 71.33%.

  5. In Vivo Imaging of Tau Pathology Using Magnetic Resonance Imaging Textural Analysis

    Directory of Open Access Journals (Sweden)

    Niall Colgan

    2017-11-01

    Full Text Available Background: Non-invasive characterization of the pathological features of Alzheimer's disease (AD could enhance patient management and the development of therapeutic strategies. Magnetic resonance imaging texture analysis (MRTA has been used previously to extract texture descriptors from structural clinical scans in AD to determine cerebral tissue heterogeneity. In this study, we examined the potential of MRTA to specifically identify tau pathology in an AD mouse model and compared the MRTA metrics to histological measures of tau burden.Methods: MRTA was applied to T2 weighted high-resolution MR images of nine 8.5-month-old rTg4510 tau pathology (TG mice and 16 litter matched wild-type (WT mice. MRTA comprised of the filtration-histogram technique, where the filtration step extracted and enhanced features of different sizes (fine, medium, and coarse texture scales, followed by quantification of texture using histogram analysis (mean gray level intensity, mean intensity, entropy, uniformity, skewness, standard-deviation, and kurtosis. MRTA was applied to manually segmented regions of interest (ROI drawn within the cortex, hippocampus, and thalamus regions and the level of tau burden was assessed in equivalent regions using histology.Results: Texture parameters were markedly different between WT and TG in the cortex (E, p < 0.01, K, p < 0.01, the hippocampus (K, p < 0.05 and in the thalamus (K, p < 0.01. In addition, we observed significant correlations between histological measurements of tau burden and kurtosis in the cortex, hippocampus and thalamus.Conclusions: MRTA successfully differentiated WT and TG in brain regions with varying degrees of tau pathology (cortex, hippocampus, and thalamus based on T2 weighted MR images. Furthermore, the kurtosis measurement correlated with histological measures of tau burden. This initial study indicates that MRTA may have a role in the early diagnosis of AD and the assessment of tau pathology using

  6. Dental microwear texture analysis of late Pliocene Procynocephalus subhimalayanus (Primates: Cercopithecidae) of the Upper Siwaliks, India

    Science.gov (United States)

    Williams, Frank L'Engle; Holmes, Noelle A.

    2012-09-01

    Late Pliocene Procynocephalus subhimalayanus from the Upper Siwaliks, India is known from only three specimens. The dietary proclivities of this taxon have implications for reconstructing the paleoecology of the Upper Siwaliks. The dental microwear texture properties of Procynocephalus are compared to those from extant tropical forest primates including Alouatta palliata (n = 11), Cebus apella (n = 13), Gorilla gorilla (n = 9), Lophocebus albigena (n = 15) and Trachypithecus cristatus (n = 12). Dental microwear textures are generated by scanning the surface enamel of Facet 9 using white-light confocal microscopy at 100x. Four variables were extracted from scale-sensitive fractal analysis, and the data were ranked before ANOVA with post-hoc tests of significance and multivariate analyses were performed. Procynocephalus clusters closest to Lophocebus, Cebus and some Gorilla specimens suggesting hard-object feeding characterized a portion of its diet. The dental microwear texture of Procynocephalus supports interpretations of widespread grasslands of the Late Pliocene Kansal Formation (Pinjor zone). The extreme enamel complexity characterizing Procynocephalus may derive from consumption of underground storage organs, or other foods with high grit loads. Foods consumed near ground level carry a heavy load of abrasive minerals possibly contributing to greater enamel surface complexity and textural fill volume.

  7. Soil texture and climatc conditions for biocrust growth limitation: a meta analysis

    Science.gov (United States)

    Fischer, Thomas; Subbotina, Mariia

    2015-04-01

    Along with afforestation, attempts have been made to combat desertification by managing soil crusts, and is has been reported that recovery rates of biocrusts are dependent on many factors, including the type, severity, and extent of disturbance; structure of the vascular plant community; conditions of adjoining substrates; availability of inoculation material; and climate during and after disturbance (Belnap & Eldridge 2001). Because biological soil crusts are known to be more stable on and to prefer fine substrates (Belnap 2001), the question arises as to how successful crust management practices can be applied to coarser soil. In previous studies we observed similar crust biomasses on finer soils under arid and on coarser soils under temperate conditions. We hypothesized that the higher water holding capacity of finer substrates would favor crust development, and that the amount of silt and clay in the substrate that is required for enhanced crust development would vary with changes in climatic conditions. In a global meta study, climatic and soil texture threshold values promoting BSC growth were derived. While examining literature sources, it became evident that the amount of studies to be incorporated into this meta analysis was reversely related to the amount of common environmental parameters they share. We selected annual mean precipitaion, mean temperature and the amount of silt and clay as driving variables for crust growth. Response variable was the "relative crust biomass", which was computed per literature source as the ratio between each individual crust biomass value of the given study to the study maximum value reported. We distinguished lichen, green algal, cyanobacterial and moss crusts. To quantify threshold conditions at which crust biomass responded to differences in texture and climate, we (I) determined correlations between bioclimatic variables, (II) calculated linear models to determine the effect of typical climatic variables with soil

  8. Quantitative Evaluation of Trabecular Bone Structure by Calcaneus MR Images Texture Analysis of Healthy Volunteers and Osteoporotic Subjects

    National Research Council Canada - National Science Library

    Herlidou, S

    2001-01-01

    ...), Texture analysis is not used very, frequently since the interpretation of the large number of calculated parameters is difficult, We here apply multiparametric data analyses such as Correspondence Factorial Analysis (CFA...

  9. NDVI and Panchromatic Image Correlation Using Texture Analysis

    Science.gov (United States)

    2010-03-01

    6 Figure 5. Spectral reflectance of vegetation and soil from 0.4 to 1.1 mm (From Perry...should help the classification methods to be able to classify kelp. Figure 5. Spectral reflectance of vegetation and soil from 0.4 to 1.1 mm...1988). Image processing software for imaging spectrometry analysis. Remote Sensing of Enviroment , 24: 201–210. Perry, C., & Lautenschlager, L. F

  10. Textural analysis of pre-therapeutic [18F]-FET-PET and its correlation with tumor grade and patient survival in high-grade gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Pyka, Thomas; Hiob, Daniela; Wester, Hans-Juergen [Klinikum Rechts der Isar der TU Muenchen, Department of Nuclear Medicine, Munich (Germany); Gempt, Jens; Ringel, Florian; Meyer, Bernhard [Klinikum Rechts der Isar der TU Muenchen, Neurosurgic Department, Munich (Germany); Schlegel, Juergen [Klinikum Rechts der Isar der TU Muenchen, Institute of Pathology and Neuropathology, Munich (Germany); Bette, Stefanie [Klinikum Rechts der Isar der TU Muenchen, Neuroradiologic department, Munich (Germany); Foerster, Stefan [Klinikum Rechts der Isar der TU Muenchen, Department of Nuclear Medicine, Munich (Germany); Klinikum Rechts der Isar der TU Muenchen, TUM Neuroimaging Center (TUM-NIC), Munich (Germany)

    2016-01-15

    Amino acid positron emission tomography (PET) with [18F]-fluoroethyl-L-tyrosine (FET) is well established in the diagnostic work-up of malignant brain tumors. Analysis of FET-PET data using tumor-to-background ratios (TBR) has been shown to be highly valuable for the detection of viable hypermetabolic brain tumor tissue; however, it has not proven equally useful for tumor grading. Recently, textural features in 18-fluorodeoxyglucose-PET have been proposed as a method to quantify the heterogeneity of glucose metabolism in a variety of tumor entities. Herein we evaluate whether textural FET-PET features are of utility for grading and prognostication in patients with high-grade gliomas. One hundred thirteen patients (70 men, 43 women) with histologically proven high-grade gliomas were included in this retrospective study. All patients received static FET-PET scans prior to first-line therapy. TBR (max and mean), volumetric parameters and textural parameters based on gray-level neighborhood difference matrices were derived from static FET-PET images. Receiver operating characteristic (ROC) and discriminant function analyses were used to assess the value for tumor grading. Kaplan-Meier curves and univariate and multivariate Cox regression were employed for analysis of progression-free and overall survival. All FET-PET textural parameters showed the ability to differentiate between World Health Organization (WHO) grade III and IV tumors (p < 0.001; AUC 0.775). Further improvement in discriminatory power was possible through a combination of texture and metabolic tumor volume, classifying 85 % of tumors correctly (AUC 0.830). TBR and volumetric parameters alone were correlated with tumor grade, but showed lower AUC values (0.644 and 0.710, respectively). Furthermore, a correlation of FET-PET texture but not TBR was shown with patient PFS and OS, proving significant in multivariate analysis as well. Volumetric parameters were predictive for OS, but this correlation did not

  11. MRI Texture Analysis Reflects Histopathology Parameters in Thyroid Cancer - A First Preliminary Study.

    Science.gov (United States)

    Meyer, Hans-Jonas; Schob, Stefan; Höhn, Anne Kathrin; Surov, Alexey

    2017-12-01

    Thyroid cancer represents the most frequent malignancy of the endocrine system with an increasing incidence worldwide. Novel imaging techniques are able to further characterize tumors and even predict histopathology features. Texture analysis is an emergent imaging technique to extract extensive data from an radiology images. The present study was therefore conducted to identify possible associations between texture analysis and histopathology parameters in thyroid cancer. The radiological database was retrospectively reviewed for thyroid carcinoma. Overall, 13 patients (3 females, 23.1%) with a mean age of 61.6 years were identified. The MaZda program was used for texture analysis. The T1-precontrast and T2-weighted images were analyzed and overall 279 texture feature for each sequence was investigated. For every patient cell count, Ki67-index and p53 count were investigated. Several significant correlations between texture features and histopathology were identified. Regarding T1-weighted images, S(0;1)Sum Averg correlated the most with cell count (r=0.82). An inverse correlations with S(5;0)AngScMom, S(5;0)DifVarnc S(5;0), DiffEntrp and GrNonZeros (r=-0.69, -0.66, -0.69 and -0.63, respectively) was also identified. For T2-weighted images, Variance with r=0.63 was the highest coefficient, WavEnLL_S3 correlated inversely with cell count (r=-0.57). WavEnLL_S2 derived from T1-weighted images was the highest coefficient r=-0.80, S(0;5)SumVarnc was positively with r=0.74. Regarding T2-weighted images WavEnHL_s-1 was inverse correlated with Ki67 index (r=-0.77). S(1;0)Correlat was with r=0.75 the best correlation with Ki67 index. For T1-weighed images S(5;0)SumofSqs was the best with r=0.65 with p53 count. For T2-weighted images S(1;-1)SumEntrp was the inverse correlation with r=-0.72, whereas S(0;4)AngScMom correlated positively with r=0.63. MRI texture analysis derived from conventional sequences reflects histopathology features in thyroid cancer. This technique

  12. Understanding Crystal Populations: The Role of Textural Analysis in Determining Magmatic Timescales

    Science.gov (United States)

    Jerram, D. A.

    2006-12-01

    Crystal populations in igneous rocks that erupt at the Earths surface act as records of magma chamber processes at depth, predominantly recording episodes of growth/nucleation and geochemical changes within the host body. Detailed inspection of such crystal populations, however, reveals a complex crystal cargo that comprises crystals which have grown directly from the host, crystals that have spent one or more protracted periods being isolated from the host magma and crystals that originated from a completely different magma body and/or country rock. To further interrogate this crystal cargo we can use textural analysis techniques to fully quantify the crystal population and gather important information about the population, such as crystal morphology, spatial distribution and size relationships. When quantified, such data can be used to better constrain the different components of the resultant crystal population and how they relate to each other. Additionally, by combining textural analysis information with geochemical analysis, a powerful measure of magma timescales and magma chamber processes results. In this contribution the different types of textural analysis techniques in 2D and 3D are introduced with examples from both plutonic and volcanic systems presented to highlight the roll of this approach to quantifying magma timescales.

  13. Comparison of textural atributes of selected meat sausages using instrumental analysis

    Directory of Open Access Journals (Sweden)

    Vladimír Vietoris

    2013-03-01

    Full Text Available Normal 0 21 false false false SK X-NONE X-NONE The aim of the study was to compare textural atributes of selected meat sausages using instrumental analysis. For this purpose, seven different meat sausage samples were treated by instrumental analysis, by the use of Warner-Bratzler probe,  to find differences for two selected textural parameter firmness and work of shear. As expected, various values of mentioned atributes were obtained for different samples tested in fresh stage and after storage under controlled conditions (48 hrs., 30 °C temp., and 60 % R.H. before and after cooking. For statistical evaluation of results, paired T test was used, statistically significant differences were taken at pdoi:10.5219/273

  14. SU-E-J-265: Feasibility Study of Texture Analysis for Prognosis of Local Tumor Recurrence Within 5-Years for Pharyngeal-Laryngeal Carcinoma Patients Received Radiotherapy Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Huang, W; Tu, S [Chang Gung University, Kwei-shan, Tao-Yuan, Taiwan (China)

    2015-06-15

    Purpose: Pharyngeal and laryngeal carcinomas (PLC) are among the top leading cancers in Asian populations. Typically the tumor may recur and progress in a short period of time if radiotherapy fails to deliver a successful treatment. Here we used image texture features extracted from images of computed tomography (CT) planning and conducted a retrospective study to evaluate whether texture analysis is a feasible approach to predict local tumor recurrence for PLC patients received radiotherapy treatment. Methods: CT planning images of 100 patients with PLC treated by radiotherapy at our facility between 2001 and 2010 are collected. These patients were received two separate CT scans, before and mid-course of the treatment delivery. Before the radiotherapy, a CT scanning was used for the first treatment planning. A total of 30 fractions were used in the treatment and patients were scanned with a second CT around the end of the fifteenth delivery for an adaptive treatment planning. Only patients who were treated with intensity modulated radiation therapy and RapidArc were selected. Treatment planning software of Eclipse was used. The changes of texture parameters between two CT acquisitions were computed to determine whether they were correlated to the local tumor recurrence. The following texture parameters were used in the preliminary assessment: mean, variance, standard deviation, skewness, kurtosis, energy, entropy, inverse difference moment, cluster shade, inertia, cluster prominence, gray-level co-occurrence matrix, and gray-level run-length matrix. The study was reviewed and approved by the committee of our institutional review board. Results: Our calculations suggested the following texture parameters were correlated with the local tumor recurrence: skewness, kurtosis, entropy, and inertia (p<0.0.05). Conclusion: The preliminary results were positive. However some works remain crucial to be completed, including addition of texture parameters for different image

  15. 3D Texture Analysis in Renal Cell Carcinoma Tissue Image Grading

    Science.gov (United States)

    Cho, Nam-Hoon; Choi, Heung-Kook

    2014-01-01

    One of the most significant processes in cancer cell and tissue image analysis is the efficient extraction of features for grading purposes. This research applied two types of three-dimensional texture analysis methods to the extraction of feature values from renal cell carcinoma tissue images, and then evaluated the validity of the methods statistically through grade classification. First, we used a confocal laser scanning microscope to obtain image slices of four grades of renal cell carcinoma, which were then reconstructed into 3D volumes. Next, we extracted quantitative values using a 3D gray level cooccurrence matrix (GLCM) and a 3D wavelet based on two types of basis functions. To evaluate their validity, we predefined 6 different statistical classifiers and applied these to the extracted feature sets. In the grade classification results, 3D Haar wavelet texture features combined with principal component analysis showed the best discrimination results. Classification using 3D wavelet texture features was significantly better than 3D GLCM, suggesting that the former has potential for use in a computer-based grading system. PMID:25371701

  16. 3D Texture Analysis in Renal Cell Carcinoma Tissue Image Grading

    Directory of Open Access Journals (Sweden)

    Tae-Yun Kim

    2014-01-01

    Full Text Available One of the most significant processes in cancer cell and tissue image analysis is the efficient extraction of features for grading purposes. This research applied two types of three-dimensional texture analysis methods to the extraction of feature values from renal cell carcinoma tissue images, and then evaluated the validity of the methods statistically through grade classification. First, we used a confocal laser scanning microscope to obtain image slices of four grades of renal cell carcinoma, which were then reconstructed into 3D volumes. Next, we extracted quantitative values using a 3D gray level cooccurrence matrix (GLCM and a 3D wavelet based on two types of basis functions. To evaluate their validity, we predefined 6 different statistical classifiers and applied these to the extracted feature sets. In the grade classification results, 3D Haar wavelet texture features combined with principal component analysis showed the best discrimination results. Classification using 3D wavelet texture features was significantly better than 3D GLCM, suggesting that the former has potential for use in a computer-based grading system.

  17. Reproducibility of tumor uptake heterogeneity characterization through textural feature analysis in 18F-FDG PET.

    Science.gov (United States)

    Tixier, Florent; Hatt, Mathieu; Le Rest, Catherine Cheze; Le Pogam, Adrien; Corcos, Laurent; Visvikis, Dimitris

    2012-05-01

    (18)F-FDG PET measurement of standardized uptake value (SUV) is increasingly used for monitoring therapy response and predicting outcome. Alternative parameters computed through textural analysis were recently proposed to quantify the heterogeneity of tracer uptake by tumors as a significant predictor of response. The primary objective of this study was to evaluate the reproducibility of these heterogeneity measurements. Double baseline (18)F-FDG PET scans were acquired within 4 d of each other for 16 patients before any treatment was considered. A Bland-Altman analysis was performed on 8 parameters based on histogram measurements and 17 parameters based on textural heterogeneity features after discretization with values between 8 and 128. The reproducibility of maximum and mean SUV was similar to that in previously reported studies, with a mean percentage difference of 4.7% ± 19.5% and 5.5% ± 21.2%, respectively. By comparison, better reproducibility was measured for some textural features describing local heterogeneity of tracer uptake, such as entropy and homogeneity, with a mean percentage difference of -2% ± 5.4% and 1.8% ± 11.5%, respectively. Several regional heterogeneity parameters such as variability in the intensity and size of regions of homogeneous activity distribution had reproducibility similar to that of SUV measurements, with 95% confidence intervals of -22.5% to 3.1% and -1.1% to 23.5%, respectively. These parameters were largely insensitive to the discretization range. Several parameters derived from textural analysis describing heterogeneity of tracer uptake by tumors on local and regional scales had reproducibility similar to or better than that of simple SUV measurements. These reproducibility results suggest that these (18)F-FDG PET-derived parameters, which have already been shown to have predictive and prognostic value in certain cancer models, may be used to monitor therapy response and predict patient outcome.

  18. SU-D-9A-03: STAMP: Simulator for Texture Analysis in MRI/PET

    Energy Technology Data Exchange (ETDEWEB)

    Laberge, S; Vallieres, M; Levesque, I R.; El Naqa, I [McGill University, Montreal, QC (Canada)

    2014-06-01

    Purpose: To develop a convenient simulation platform to facilitate PET/MR image analysis with the prospect of gaining a better understanding of the influence of acquisition parameters on PET/MRI textural features. The simulation platform is demonstrated by showing textural variations of a representative case study using different image acquisition parameters. Methods: The simulation platform is composed of MRI simulators JEMRIS and SIMRI to achieve simulations of customized MRI sequences on sample tumor models. The PET simulator GATE is used to get 2D and 3D Monte Carlo acquisitions of voxelized PET sources using a phantom geometry and a customized scanner architecture. The platform incorporates a series of graphical user interfaces written in Matlab. Two GUIs are used to facilitate communication with the simulation executables installed on a computer cluster. A third GUI is used to collect and display the clinical and simulated images, as well as fused PET/MRI images, and perform computation of textural features.To illustrate the capabilities of this platform, one FDG-PET and T1-weighted (T1w) digitized tumor models were generated from clinical images of a soft-tissue sarcoma patient. Numerically simulated MR images were produced using 3 different echo times (TE) and 5 different repetition times (TR). PET 2D images were simulated using an OSEM algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. Results: STAMP was successfully used to produce numerically simulated FDG-PET and MRI images, and to calculate their corresponding textures. Three typical textures (GLCM-Contrast, GLSZM-ZSV and NGTDM-Coarseness) were found to vary by a range of 45% on average compared to reference scanning conditions in the case of FDG-PET, and by a range of 40% in the case of T1w MRI. Conclusion: We have successfully developed a Matlab-based simulation platform to facilitate PET/MRI texture image analysis for outcome prediction.

  19. Wavelet analysis enables system-independent texture analysis of optical coherence tomography images

    Science.gov (United States)

    Lingley-Papadopoulos, Colleen A.; Loew, Murray H.; Zara, Jason M.

    2009-07-01

    Texture analysis for tissue characterization is a current area of optical coherence tomography (OCT) research. We discuss some of the differences between OCT systems and the effects those differences have on the resulting images and subsequent image analysis. In addition, as an example, two algorithms for the automatic recognition of bladder cancer are compared: one that was developed on a single system with no consideration for system differences, and one that was developed to address the issues associated with system differences. The first algorithm had a sensitivity of 73% and specificity of 69% when tested using leave-one-out cross-validation on data taken from a single system. When tested on images from another system with a different central wavelength, however, the method classified all images as cancerous regardless of the true pathology. By contrast, with the use of wavelet analysis and the removal of system-dependent features, the second algorithm reported sensitivity and specificity values of 87 and 58%, respectively, when trained on images taken with one imaging system and tested on images taken with another.

  20. Wavelet analysis enables system-independent texture analysis of optical coherence tomography images.

    Science.gov (United States)

    Lingley-Papadopoulos, Colleen A; Loew, Murray H; Zara, Jason M

    2009-01-01

    Texture analysis for tissue characterization is a current area of optical coherence tomography (OCT) research. We discuss some of the differences between OCT systems and the effects those differences have on the resulting images and subsequent image analysis. In addition, as an example, two algorithms for the automatic recognition of bladder cancer are compared: one that was developed on a single system with no consideration for system differences, and one that was developed to address the issues associated with system differences. The first algorithm had a sensitivity of 73% and specificity of 69% when tested using leave-one-out cross-validation on data taken from a single system. When tested on images from another system with a different central wavelength, however, the method classified all images as cancerous regardless of the true pathology. By contrast, with the use of wavelet analysis and the removal of system-dependent features, the second algorithm reported sensitivity and specificity values of 87 and 58%, respectively, when trained on images taken with one imaging system and tested on images taken with another.

  1. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer

    International Nuclear Information System (INIS)

    Bates, Anthony; Miles, Kenneth

    2017-01-01

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at <5%. Eighty-eight T2-weighted images in 18 patients demonstrated abnormal PSMA expression within the TZ on PET-MR. 123 images were PSMA negative. Based on the corrected p-value of 0.005, significant differences between PSMA positive and negative slices were found for 16 texture parameters: Standard deviation and mean of positive pixels for all spatial filters (p = <0.0001 for both at all spatial scaling factor (SSF) values) and mean intensity following filtration for SSF 3-6 mm (p = 0.0002-0.0018). Abnormal expression of PSMA within the TZ is associated with altered texture on T2-weighted MR, providing validation of MRTA for the detection of TZ prostate cancer. (orig.)

  2. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bates, Anthony [Princess Alexandra Hospital, Brisbane (Australia); Miles, Kenneth [Princess Alexandra Hospital, Department of Diagnostic Radiology, Brisbane, QLD (Australia); University College London, Institute of Nuclear Medicine, London (United Kingdom)

    2017-12-15

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at <5%. Eighty-eight T2-weighted images in 18 patients demonstrated abnormal PSMA expression within the TZ on PET-MR. 123 images were PSMA negative. Based on the corrected p-value of 0.005, significant differences between PSMA positive and negative slices were found for 16 texture parameters: Standard deviation and mean of positive pixels for all spatial filters (p = <0.0001 for both at all spatial scaling factor (SSF) values) and mean intensity following filtration for SSF 3-6 mm (p = 0.0002-0.0018). Abnormal expression of PSMA within the TZ is associated with altered texture on T2-weighted MR, providing validation of MRTA for the detection of TZ prostate cancer. (orig.)

  3. A vegetation height classification approach based on texture analysis of a single VHR image

    International Nuclear Information System (INIS)

    Petrou, Z I; Manakos, I; Stathaki, T; Tarantino, C; Adamo, M; Blonda, P

    2014-01-01

    Vegetation height is a crucial feature in various applications related to ecological mapping, enhancing the discrimination among different land cover or habitat categories and facilitating a series of environmental tasks, ranging from biodiversity monitoring and assessment to landscape characterization, disaster management and conservation planning. Primary sources of information on vegetation height include in situ measurements and data from active satellite or airborne sensors, which, however, may often be non-affordable or unavailable for certain regions. Alternative approaches on extracting height information from very high resolution (VHR) satellite imagery based on texture analysis, have recently been presented, with promising results. Following the notion that multispectral image bands may often be highly correlated, data transformation and dimensionality reduction techniques are expected to reduce redundant information, and thus, the computational cost of the approaches, without significantly compromising their accuracy. In this paper, dimensionality reduction is performed on a VHR image and textural characteristics are calculated on its reconstructed approximations, to show that their discriminatory capabilities are maintained up to a large degree. Texture analysis is also performed on the projected data to investigate whether the different height categories can be distinguished in a similar way

  4. Texture analysis of speckle in optical coherence tomography images of tissue phantoms

    International Nuclear Information System (INIS)

    Gossage, Kirk W; Smith, Cynthia M; Kanter, Elizabeth M; Hariri, Lida P; Stone, Alice L; Rodriguez, Jeffrey J; Williams, Stuart K; Barton, Jennifer K

    2006-01-01

    Optical coherence tomography (OCT) is an imaging modality capable of acquiring cross-sectional images of tissue using back-reflected light. Conventional OCT images have a resolution of 10-15 μm, and are thus best suited for visualizing tissue layers and structures. OCT images of collagen (with and without endothelial cells) have no resolvable features and may appear to simply show an exponential decrease in intensity with depth. However, examination of these images reveals that they display a characteristic repetitive structure due to speckle.The purpose of this study is to evaluate the application of statistical and spectral texture analysis techniques for differentiating living and non-living tissue phantoms containing various sizes and distributions of scatterers based on speckle content in OCT images. Statistically significant differences between texture parameters and excellent classification rates were obtained when comparing various endothelial cell concentrations ranging from 0 cells/ml to 25 million cells/ml. Statistically significant results and excellent classification rates were also obtained using various sizes of microspheres with concentrations ranging from 0 microspheres/ml to 500 million microspheres/ml. This study has shown that texture analysis of OCT images may be capable of differentiating tissue phantoms containing various sizes and distributions of scatterers

  5. BMI and WHR Are Reflected in Female Facial Shape and Texture: A Geometric Morphometric Image Analysis.

    Directory of Open Access Journals (Sweden)

    Christine Mayer

    Full Text Available Facial markers of body composition are frequently studied in evolutionary psychology and are important in computational and forensic face recognition. We assessed the association of body mass index (BMI and waist-to-hip ratio (WHR with facial shape and texture (color pattern in a sample of young Middle European women by a combination of geometric morphometrics and image analysis. Faces of women with high BMI had a wider and rounder facial outline relative to the size of the eyes and lips, and relatively lower eyebrows. Furthermore, women with high BMI had a brighter and more reddish skin color than women with lower BMI. The same facial features were associated with WHR, even though BMI and WHR were only moderately correlated. Yet BMI was better predictable than WHR from facial attributes. After leave-one-out cross-validation, we were able to predict 25% of variation in BMI and 10% of variation in WHR by facial shape. Facial texture predicted only about 3-10% of variation in BMI and WHR. This indicates that facial shape primarily reflects total fat proportion, rather than the distribution of fat within the body. The association of reddish facial texture in high-BMI women may be mediated by increased blood pressure and superficial blood flow as well as diet. Our study elucidates how geometric morphometric image analysis serves to quantify the effect of biological factors such as BMI and WHR to facial shape and color, which in turn contributes to social perception.

  6. Intratumoral Heterogeneity of Breast Cancer Xenograft Models: Texture Analysis of Diffusion-Weighted MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Bo La; Cho, Nariya; Li, Mulun; Song, In Chan; Moon, Woo Kyung [Dept. of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jang, Min Hye; Park, So Yeon; Kim, Bo Young [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Kang, Ho Chul [Dept. of Computer Science and Engineering, Seoul National University, Seoul (Korea, Republic of)

    2014-10-15

    To investigate whether there is a relationship between texture analysis parameters of apparent diffusion coefficient (ADC) maps and histopathologic features of MCF-7 and MDA-MB-231 xenograft models. MCF-7 estradiol (+), MCF-7 estradiol (-), and MDA-MB-231 xenograft models were made with approval of the animal care committee. Twelve tumors of MCF-7 estradiol (+), 9 tumors of MCF-7 estradiol (-), and 6 tumors in MDA-MB-231 were included. Diffusion-weighted MR images were obtained on a 9.4-T system. An analysis of the first and second order texture analysis of ADC maps was performed. The texture analysis parameters and histopathologic features were compared among these groups by the analysis of variance test. Correlations between texture parameters and histopathologic features were analyzed. We also evaluated the intraobserver agreement in assessing the texture parameters. MCF-7 estradiol (+) showed a higher standard deviation, maximum, skewness, and kurtosis of ADC values than MCF-7 estradiol (-) and MDA-MB-231 (p < 0.01 for all). The contrast of the MCF-7 groups was higher than that of the MDA-MB-231 (p 0.004). The correlation (COR) of the texture analysis of MCF-7 groups was lower than that of MDA-MB-231 (p < 0.001). The histopathologic analysis showed that Ki-67mean and Ki-67diff of MCF-7 estradiol (+) were higher than that of MCF-7 estradiol (-) or MDA-MB-231 (p < 0.05). The microvessel density (MVD)mean and MVDdiff of MDA-MB-231 were higher than those of MCF-7 groups (p < 0.001). A diffuse-multifocal necrosis was more frequently found in MDA-MB-231 (p < 0.001). The proportion of necrosis moderately correlated with the contrast (r = -0.438, p = 0.022) and strongly with COR (r = 0.540, p 0.004). Standard deviation (r = 0.622, r = 0.437), skewness (r = 0.404, r 0.484), and kurtosis (r = 0.408, r = 0.452) correlated with Ki-67 mean and Ki-67diff (p < 0.05 for all). COR moderately correlated with Ki-67diff (r -0.388, p = 0.045). Skewness (r = -0.643, r = -0

  7. Towards true 3D textural analysis; using your crystal mush wisely.

    Science.gov (United States)

    Jerram, D. A.; Morgan, D. J.; Pankhurst, M. J.

    2014-12-01

    The crystal cargo that is found in volcanic and plutonic rocks contains a wealth of information about magmatic mush processes, crystallisation history, crystal entrainment and recycling. Phenocryst populations predominantly record episodes of growth/nucleation and bulk geochemical changes within an evolving crystal-melt body. Ante- and xeno-crysts provide useful clues to the nature of mush interaction with wall rock and with principal magma(s). Furthermore, crystal evolutions (core to rim) record pathways through pressure, temperature and compositional space. These can often illustrate complex recycling within systems, describing the plumbing architecture. Understanding this architecture underpins our knowledge of how igneous systems can interact with the crust, grow, freeze, re-mobilise and prime for eruption. Initially, 2D studies produced corrected 3D crystal size distributions to help provide information about nucleation and residence times. It immediately became clear that crystal shape is an important factor in determining the confidence placed upon 3D reconstructions of 2D data. Additionally studies utilised serial sections of medium- to coarse-grain-size populations which allowed 3D reconstruction using modelling software to be improved, since size and shape etc. can be directly constrained. Finally the advent of textural studies using X-ray tomography has revolutionised the way in which we can inspect the crystal cargo in mushy systems, allowing us to image in great detail crystal packing arrangements, 3D CSDs, shapes and orientations etc. The latest most innovative studies use X-ray micro-computed tomography to rapidly characterise chemical populations within the crystal cargo, adding a further dimension to this approach, and implies the ability to untangle magmatic chemical components to better understand their individual and combined evolution. In this contribution key examples of the different types of textural analysis techniques in 2D and 3D

  8. Feasibility of opportunistic osteoporosis screening in routine contrast-enhanced multi detector computed tomography (MDCT) using texture analysis.

    Science.gov (United States)

    Mookiah, M R K; Rohrmeier, A; Dieckmeyer, M; Mei, K; Kopp, F K; Noel, P B; Kirschke, J S; Baum, T; Subburaj, K

    2018-04-01

    This study investigated the feasibility of opportunistic osteoporosis screening in routine contrast-enhanced MDCT exams using texture analysis. The results showed an acceptable reproducibility of texture features, and these features could discriminate healthy/osteoporotic fracture cohort with an accuracy of 83%. This aim of this study is to investigate the feasibility of opportunistic osteoporosis screening in routine contrast-enhanced MDCT exams using texture analysis. We performed texture analysis at the spine in routine MDCT exams and investigated the effect of intravenous contrast medium (IVCM) (n = 7), slice thickness (n = 7), the long-term reproducibility (n = 9), and the ability to differentiate healthy/osteoporotic fracture cohort (n = 9 age and gender matched pairs). Eight texture features were extracted using gray level co-occurrence matrix (GLCM). The independent sample t test was used to rank the features of healthy/fracture cohort and classification was performed using support vector machine (SVM). The results revealed significant correlations between texture parameters derived from MDCT scans with and without IVCM (r up to 0.91) slice thickness of 1 mm versus 2 and 3 mm (r up to 0.96) and scan-rescan (r up to 0.59). The performance of the SVM classifier was evaluated using 10-fold cross-validation and revealed an average classification accuracy of 83%. Opportunistic osteoporosis screening at the spine using specific texture parameters (energy, entropy, and homogeneity) and SVM can be performed in routine contrast-enhanced MDCT exams.

  9. Computer-assisted liver graft steatosis assessment via learning-based texture analysis.

    Science.gov (United States)

    Moccia, Sara; Mattos, Leonardo S; Patrini, Ilaria; Ruperti, Michela; Poté, Nicolas; Dondero, Federica; Cauchy, François; Sepulveda, Ailton; Soubrane, Olivier; De Momi, Elena; Diaspro, Alberto; Cesaretti, Manuela

    2018-05-23

    Fast and accurate graft hepatic steatosis (HS) assessment is of primary importance for lowering liver dysfunction risks after transplantation. Histopathological analysis of biopsied liver is the gold standard for assessing HS, despite being invasive and time consuming. Due to the short time availability between liver procurement and transplantation, surgeons perform HS assessment through clinical evaluation (medical history, blood tests) and liver texture visual analysis. Despite visual analysis being recognized as challenging in the clinical literature, few efforts have been invested to develop computer-assisted solutions for HS assessment. The objective of this paper is to investigate the automatic analysis of liver texture with machine learning algorithms to automate the HS assessment process and offer support for the surgeon decision process. Forty RGB images of forty different donors were analyzed. The images were captured with an RGB smartphone camera in the operating room (OR). Twenty images refer to livers that were accepted and 20 to discarded livers. Fifteen randomly selected liver patches were extracted from each image. Patch size was [Formula: see text]. This way, a balanced dataset of 600 patches was obtained. Intensity-based features (INT), histogram of local binary pattern ([Formula: see text]), and gray-level co-occurrence matrix ([Formula: see text]) were investigated. Blood-sample features (Blo) were included in the analysis, too. Supervised and semisupervised learning approaches were investigated for feature classification. The leave-one-patient-out cross-validation was performed to estimate the classification performance. With the best-performing feature set ([Formula: see text]) and semisupervised learning, the achieved classification sensitivity, specificity, and accuracy were 95, 81, and 88%, respectively. This research represents the first attempt to use machine learning and automatic texture analysis of RGB images from ubiquitous smartphone

  10. Texture analysis on MR images helps predicting non-response to NAC in breast cancer

    International Nuclear Information System (INIS)

    Michoux, N.; Van den Broeck, S.; Lacoste, L.; Fellah, L.; Galant, C.; Berlière, M.; Leconte, I.

    2015-01-01

    To assess the performance of a predictive model of non-response to neoadjuvant chemotherapy (NAC) in patients with breast cancer based on texture, kinetic, and BI-RADS parameters measured from dynamic MRI. Sixty-nine patients with invasive ductal carcinoma of the breast who underwent pre-treatment MRI were studied. Morphological parameters and biological markers were measured. Pathological complete response was defined as the absence of invasive and in situ cancer in breast and nodes. Pathological non-responders, partial and complete responders were identified. Dynamic imaging was performed at 1.5 T with a 3D axial T1W GRE fat-suppressed sequence. Visual texture, kinetic and BI-RADS parameters were measured in each lesion. ROC analysis and leave-one-out cross-validation were used to assess the performance of individual parameters, then the performance of multi-parametric models in predicting non-response to NAC. A model based on four pre-NAC parameters (inverse difference moment, GLN, LRHGE, wash-in) and k-means clustering as statistical classifier identified non-responders with 84 % sensitivity. BI-RADS mass/non-mass enhancement, biological markers and histological grade did not contribute significantly to the prediction. Pre-NAC texture and kinetic parameters help predicting non-benefit to NAC. Further testing including larger groups of patients with different tumor subtypes is needed to improve the generalization properties and validate the performance of the predictive model

  11. Analysis of elastic strain and crystallographic texture in poled rhombohedral PZT ceramics

    International Nuclear Information System (INIS)

    Hall, D.A.; Steuwer, A.; Cherdhirunkorn, B.; Mori, T.; Withers, P.J.

    2006-01-01

    The elastic strain and crystallographic texture of a rhombohedral lead zirconate titanate ceramic have been characterised in the remanent state, after poling, using high-energy synchrotron X-ray diffraction as a function of the grain orientation ψ relative to the poling direction. It is observed that the (2 0 0) diffraction peak exhibits pronounced shifts as a function of ψ, indicating an elastic lattice strain, while others ({1 1 1}, {1 1 2} and {2 2 0}) show marked changes in intensity as a result of preferred ferroelectric domain orientation. It is shown that the (2 0 0) peak is not affected by the domain switching itself but rather acts like an elastic macrostrain sensor. A simple Eshelby analysis is used to demonstrate that both the elastic strain and texture vary systematically with ψ according to the factor (3cos 2 ψ - 1). This angular dependence is evaluated through micromechanics modelling. The physical meaning of the texture variations with ψ is also discussed

  12. A Study of Feature Extraction Using Divergence Analysis of Texture Features

    Science.gov (United States)

    Hallada, W. A.; Bly, B. G.; Boyd, R. K.; Cox, S.

    1982-01-01

    An empirical study of texture analysis for feature extraction and classification of high spatial resolution remotely sensed imagery (10 meters) is presented in terms of specific land cover types. The principal method examined is the use of spatial gray tone dependence (SGTD). The SGTD method reduces the gray levels within a moving window into a two-dimensional spatial gray tone dependence matrix which can be interpreted as a probability matrix of gray tone pairs. Haralick et al (1973) used a number of information theory measures to extract texture features from these matrices, including angular second moment (inertia), correlation, entropy, homogeneity, and energy. The derivation of the SGTD matrix is a function of: (1) the number of gray tones in an image; (2) the angle along which the frequency of SGTD is calculated; (3) the size of the moving window; and (4) the distance between gray tone pairs. The first three parameters were varied and tested on a 10 meter resolution panchromatic image of Maryville, Tennessee using the five SGTD measures. A transformed divergence measure was used to determine the statistical separability between four land cover categories forest, new residential, old residential, and industrial for each variation in texture parameters.

  13. Diabetic peripheral neuropathy assessment through texture based analysis of corneal nerve images

    Science.gov (United States)

    Silva, Susana F.; Gouveia, Sofia; Gomes, Leonor; Negrão, Luís; João Quadrado, Maria; Domingues, José Paulo; Morgado, António Miguel

    2015-05-01

    Diabetic peripheral neuropathy (DPN) is one common complication of diabetes. Early diagnosis of DPN often fails due to the non-availability of a simple, reliable, non-invasive method. Several published studies show that corneal confocal microscopy (CCM) can identify small nerve fibre damage and quantify the severity of DPN, using nerve morphometric parameters. Here, we used image texture features, extracted from corneal sub-basal nerve plexus images, obtained in vivo by CCM, to identify DPN patients, using classification techniques. A SVM classifier using image texture features was used to identify (DPN vs. No DPN) DPN patients. The accuracies were 80.6%, when excluding diabetic patients without neuropathy, and 73.5%, when including diabetic patients without diabetic neuropathy jointly with healthy controls. The results suggest that texture analysis might be used as a complementing technique for DPN diagnosis, without requiring nerve segmentation in CCM images. The results also suggest that this technique has enough sensitivity to detect early disorders in the corneal nerves of diabetic patients.

  14. Parameter optimization of parenchymal texture analysis for prediction of false-positive recalls from screening mammography

    Science.gov (United States)

    Ray, Shonket; Keller, Brad M.; Chen, Jinbo; Conant, Emily F.; Kontos, Despina

    2016-03-01

    This work details a methodology to obtain optimal parameter values for a locally-adaptive texture analysis algorithm that extracts mammographic texture features representative of breast parenchymal complexity for predicting falsepositive (FP) recalls from breast cancer screening with digital mammography. The algorithm has two components: (1) adaptive selection of localized regions of interest (ROIs) and (2) Haralick texture feature extraction via Gray- Level Co-Occurrence Matrices (GLCM). The following parameters were systematically varied: mammographic views used, upper limit of the ROI window size used for adaptive ROI selection, GLCM distance offsets, and gray levels (binning) used for feature extraction. Each iteration per parameter set had logistic regression with stepwise feature selection performed on a clinical screening cohort of 474 non-recalled women and 68 FP recalled women; FP recall prediction was evaluated using area under the curve (AUC) of the receiver operating characteristic (ROC) and associations between the extracted features and FP recall were assessed via odds ratios (OR). A default instance of mediolateral (MLO) view, upper ROI size limit of 143.36 mm (2048 pixels2), GLCM distance offset combination range of 0.07 to 0.84 mm (1 to 12 pixels) and 16 GLCM gray levels was set. The highest ROC performance value of AUC=0.77 [95% confidence intervals: 0.71-0.83] was obtained at three specific instances: the default instance, upper ROI window equal to 17.92 mm (256 pixels2), and gray levels set to 128. The texture feature of sum average was chosen as a statistically significant (p<0.05) predictor and associated with higher odds of FP recall for 12 out of 14 total instances.

  15. Texture analysis of articular cartilage traumatic changes in the knee calculated from morphological 3.0 T MR imaging

    International Nuclear Information System (INIS)

    Boutsikou, Konstantina; Kostopoulos, Spiros; Glotsos, Dimitris; Cavouras, Dionisis; Lavdas, Eleftherios; Oikonomou, Georgia; Malizos, Konstantinos; Fezoulidis, Ioannis V.; Vlychou, Marianna

    2013-01-01

    Objectives: In the present work, we aim to identify changes in the cartilage texture of the injured knee in young, physically active, patients by computer analysis of MRI images based on 3.0 T morphological sequences. Methods: Fifty-three young patients with training injury or trauma in one knee underwent MRI and arthroscopy. Textural features were computed from the MRI images of the knee-cartilages and two classes were formed of 28 normal and 16 with pathology only in the medial femoral condyle (MFC) cartilage. Results: Textural features with statistically significant differences between the two classes were found only at the MFC and the medial tibial condyle (MTC) areas. Three features-combinations, at the MFC or the MTC, maximized the between classes separation, thus, rendering alterations in cartilage texture due to injury more evident. The MFC cartilage in the pathology class was found more inhomogeneous in the distribution of gray-levels and of lower texture anisotropy and the opposed MTC cartilage, though normal on MRI and arthroscopy, was found to have lower texture anisotropy than cartilage in the normal class. Conclusion: Texture analysis may be used as an adjunct to morphological MR imaging for improving the detection of subtle cartilage changes and contributes to early therapeutic approach

  16. Texture analysis of articular cartilage traumatic changes in the knee calculated from morphological 3.0 T MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Boutsikou, Konstantina [Department of Medical Radiologic Technology, Technological Educational Institute of Athens, Ag.Spyridonos, Egaleo, Athens 12210 (Greece); Kostopoulos, Spiros; Glotsos, Dimitris; Cavouras, Dionisis [Department of Medical Instruments Technology, Technological Educational Institute of Athens, Ag.Spyridonos, Egaleo, Athens 12210 (Greece); Lavdas, Eleftherios; Oikonomou, Georgia [Department of Medical Radiologic Technology, Technological Educational Institute of Athens, Ag.Spyridonos, Egaleo, Athens 12210 (Greece); Malizos, Konstantinos [Department of Orthopaedic Surgery, University of Thessaly, School of Health Sciences, University Hospital of Larissa, Biopolis, Larissa 41110 (Greece); Fezoulidis, Ioannis V. [Department of Radiology, University of Thessaly, School of Health Sciences, University Hospital of Larissa, Biopolis, Larissa 41110 (Greece); Vlychou, Marianna, E-mail: mvlychou@med.uth.gr [Department of Radiology, University of Thessaly, School of Health Sciences, University Hospital of Larissa, Biopolis, Larissa 41110 (Greece)

    2013-08-15

    Objectives: In the present work, we aim to identify changes in the cartilage texture of the injured knee in young, physically active, patients by computer analysis of MRI images based on 3.0 T morphological sequences. Methods: Fifty-three young patients with training injury or trauma in one knee underwent MRI and arthroscopy. Textural features were computed from the MRI images of the knee-cartilages and two classes were formed of 28 normal and 16 with pathology only in the medial femoral condyle (MFC) cartilage. Results: Textural features with statistically significant differences between the two classes were found only at the MFC and the medial tibial condyle (MTC) areas. Three features-combinations, at the MFC or the MTC, maximized the between classes separation, thus, rendering alterations in cartilage texture due to injury more evident. The MFC cartilage in the pathology class was found more inhomogeneous in the distribution of gray-levels and of lower texture anisotropy and the opposed MTC cartilage, though normal on MRI and arthroscopy, was found to have lower texture anisotropy than cartilage in the normal class. Conclusion: Texture analysis may be used as an adjunct to morphological MR imaging for improving the detection of subtle cartilage changes and contributes to early therapeutic approach.

  17. Texture analysis by the Schulz reflection method: Defocalization corrections for thin films

    International Nuclear Information System (INIS)

    Chateigner, D.; Germi, P.; Pernet, M.

    1992-01-01

    A new method is described for correcting experimental data obtained from the texture analysis of thin films. The analysis employed for correcting the data usually requires the experimental curves of defocalization for a randomly oriented specimen. In view of difficulties in finding non-oriented films, a theoretical method for these corrections is proposed which uses the defocalization evolution for a bulk sample, the film thickness and the penetration depth of the incident beam in the material. This correction method is applied to a film of YBa 2 CU 3 O 7-δ on an SrTiO 3 single-crystal substrate. (orig.)

  18. Inferring species richness and turnover by statistical multiresolution texture analysis of satellite imagery.

    Directory of Open Access Journals (Sweden)

    Matteo Convertino

    Full Text Available BACKGROUND: The quantification of species-richness and species-turnover is essential to effective monitoring of ecosystems. Wetland ecosystems are particularly in need of such monitoring due to their sensitivity to rainfall, water management and other external factors that affect hydrology, soil, and species patterns. A key challenge for environmental scientists is determining the linkage between natural and human stressors, and the effect of that linkage at the species level in space and time. We propose pixel intensity based Shannon entropy for estimating species-richness, and introduce a method based on statistical wavelet multiresolution texture analysis to quantitatively assess interseasonal and interannual species turnover. METHODOLOGY/PRINCIPAL FINDINGS: We model satellite images of regions of interest as textures. We define a texture in an image as a spatial domain where the variations in pixel intensity across the image are both stochastic and multiscale. To compare two textures quantitatively, we first obtain a multiresolution wavelet decomposition of each. Either an appropriate probability density function (pdf model for the coefficients at each subband is selected, and its parameters estimated, or, a non-parametric approach using histograms is adopted. We choose the former, where the wavelet coefficients of the multiresolution decomposition at each subband are modeled as samples from the generalized Gaussian pdf. We then obtain the joint pdf for the coefficients for all subbands, assuming independence across subbands; an approximation that simplifies the computational burden significantly without sacrificing the ability to statistically distinguish textures. We measure the difference between two textures' representative pdf's via the Kullback-Leibler divergence (KL. Species turnover, or [Formula: see text] diversity, is estimated using both this KL divergence and the difference in Shannon entropy. Additionally, we predict species

  19. Texture analysis in quantitative MR imaging. Tissue characterisation of normal brain and intracranial tumours at 1.5 T

    DEFF Research Database (Denmark)

    Kjaer, L; Ring, P; Thomsen, C

    1995-01-01

    The diagnostic potential of texture analysis in quantitative tissue characterisation by MR imaging at 1.5 T was evaluated in the brain of 6 healthy volunteers and in 88 patients with intracranial tumours. Texture images were computed from calculated T1 and T2 parameter images by applying groups o...... to be successful in some cases of clinical importance. However, no discrimination between benign and malignant tumour growth was possible. Much texture information seems to be contained in MR images, which may prove useful for classification and image segmentation....

  20. INLINING 3D RECONSTRUCTION, MULTI-SOURCE TEXTURE MAPPING AND SEMANTIC ANALYSIS USING OBLIQUE AERIAL IMAGERY

    Directory of Open Access Journals (Sweden)

    D. Frommholz

    2016-06-01

    Full Text Available This paper proposes an in-line method for the simplified reconstruction of city buildings from nadir and oblique aerial images that at the same time are being used for multi-source texture mapping with minimal resampling. Further, the resulting unrectified texture atlases are analyzed for fac¸ade elements like windows to be reintegrated into the original 3D models. Tests on real-world data of Heligoland/ Germany comprising more than 800 buildings exposed a median positional deviation of 0.31 m at the fac¸ades compared to the cadastral map, a correctness of 67% for the detected windows and good visual quality when being rendered with GPU-based perspective correction. As part of the process building reconstruction takes the oriented input images and transforms them into dense point clouds by semi-global matching (SGM. The point sets undergo local RANSAC-based regression and topology analysis to detect adjacent planar surfaces and determine their semantics. Based on this information the roof, wall and ground surfaces found get intersected and limited in their extension to form a closed 3D building hull. For texture mapping the hull polygons are projected into each possible input bitmap to find suitable color sources regarding the coverage and resolution. Occlusions are detected by ray-casting a full-scale digital surface model (DSM of the scene and stored in pixel-precise visibility maps. These maps are used to derive overlap statistics and radiometric adjustment coefficients to be applied when the visible image parts for each building polygon are being copied into a compact texture atlas without resampling whenever possible. The atlas bitmap is passed to a commercial object-based image analysis (OBIA tool running a custom rule set to identify windows on the contained fac¸ade patches. Following multi-resolution segmentation and classification based on brightness and contrast differences potential window objects are evaluated against geometric

  1. Progress in realistic LOCA analysis

    International Nuclear Information System (INIS)

    Young, M.Y.; Bajorek, S.M.; Ohkawa, K.

    2004-01-01

    In 1988 the USNRC revised the ECCS rule contained in Appendix K and Section 50.46 of 10 CFR Part 50, which governs the analysis of the Loss Of Coolant Accident (LOCA). The revised regulation allows the use of realistic computer models to calculate the loss of coolant accident. In addition, the new regulation allows the use of high probability estimates of peak cladding temperature (PCT), rather than upper bound estimates. Prior to this modification, the regulations were a prescriptive set of rules which defined what assumptions must be made about the plant initial conditions and how various physical processes should be modeled. The resulting analyses were highly conservative in their prediction of the performance of the ECCS, and placed tight constraints on core power distributions, ECCS set points and functional requirements, and surveillance and testing. These restrictions, if relaxed, will allow for additional economy, flexibility, and in some cases, improved reliability and safety as well. For example, additional economy and operating flexibility can be achieved by implementing several available core and fuel rod designs to increase fuel discharge burnup and reduce neutron flux on the reactor vessel. The benefits of application of best estimate methods to LOCA analyses have typically been associated with reductions in fuel costs, resulting from optimized fuel designs, or increased revenue from power upratings. Fuel cost savings are relatively easy to quantify, and have been estimated at several millions of dollars per cycle for an individual plant. Best estimate methods are also likely to contribute significantly to reductions in O and M costs, although these reductions are more difficult to quantify. Examples of O and M cost reductions are: 1) Delaying equipment replacement. With best estimate methods, LOCA is no longer a factor in limiting power levels for plants with high tube plugging levels or degraded safety injection systems. If other requirements for

  2. Classifying brain metastases by their primary site of origin using a radiomics approach based on texture analysis: a feasibility study.

    Science.gov (United States)

    Ortiz-Ramón, Rafael; Larroza, Andrés; Ruiz-España, Silvia; Arana, Estanislao; Moratal, David

    2018-05-14

    To examine the capability of MRI texture analysis to differentiate the primary site of origin of brain metastases following a radiomics approach. Sixty-seven untreated brain metastases (BM) were found in 3D T1-weighted MRI of 38 patients with cancer: 27 from lung cancer, 23 from melanoma and 17 from breast cancer. These lesions were segmented in 2D and 3D to compare the discriminative power of 2D and 3D texture features. The images were quantized using different number of gray-levels to test the influence of quantization. Forty-three rotation-invariant texture features were examined. Feature selection and random forest classification were implemented within a nested cross-validation structure. Classification was evaluated with the area under receiver operating characteristic curve (AUC) considering two strategies: multiclass and one-versus-one. In the multiclass approach, 3D texture features were more discriminative than 2D features. The best results were achieved for images quantized with 32 gray-levels (AUC = 0.873 ± 0.064) using the top four features provided by the feature selection method based on the p-value. In the one-versus-one approach, high accuracy was obtained when differentiating lung cancer BM from breast cancer BM (four features, AUC = 0.963 ± 0.054) and melanoma BM (eight features, AUC = 0.936 ± 0.070) using the optimal dataset (3D features, 32 gray-levels). Classification of breast cancer and melanoma BM was unsatisfactory (AUC = 0.607 ± 0.180). Volumetric MRI texture features can be useful to differentiate brain metastases from different primary cancers after quantizing the images with the proper number of gray-levels. • Texture analysis is a promising source of biomarkers for classifying brain neoplasms. • MRI texture features of brain metastases could help identifying the primary cancer. • Volumetric texture features are more discriminative than traditional 2D texture features.

  3. Application of texture analysis method for classification of benign and malignant thyroid nodules in ultrasound images.

    Science.gov (United States)

    Abbasian Ardakani, Ali; Gharbali, Akbar; Mohammadi, Afshin

    2015-01-01

    The aim of this study was to evaluate computer aided diagnosis (CAD) system with texture analysis (TA) to improve radiologists' accuracy in identification of thyroid nodules as malignant or benign. A total of 70 cases (26 benign and 44 malignant) were analyzed in this study. We extracted up to 270 statistical texture features as a descriptor for each selected region of interests (ROIs) in three normalization schemes (default, 3s and 1%-99%). Then features by the lowest probability of classification error and average correlation coefficients (POE+ACC), and Fisher coefficient (Fisher) eliminated to 10 best and most effective features. These features were analyzed under standard and nonstandard states. For TA of the thyroid nodules, Principle Component Analysis (PCA), Linear Discriminant Analysis (LDA) and Non-Linear Discriminant Analysis (NDA) were applied. First Nearest-Neighbour (1-NN) classifier was performed for the features resulting from PCA and LDA. NDA features were classified by artificial neural network (A-NN). Receiver operating characteristic (ROC) curve analysis was used for examining the performance of TA methods. The best results were driven in 1-99% normalization with features extracted by POE+ACC algorithm and analyzed by NDA with the area under the ROC curve ( Az) of 0.9722 which correspond to sensitivity of 94.45%, specificity of 100%, and accuracy of 97.14%. Our results indicate that TA is a reliable method, can provide useful information help radiologist in detection and classification of benign and malignant thyroid nodules.

  4. 3D tooth microwear texture analysis in fishes as a test of dietary hypotheses of durophagy

    Science.gov (United States)

    Purnell, Mark A.; Darras, Laurent P. G.

    2016-03-01

    An understanding of how extinct animals functioned underpins our understanding of past evolutionary events, including adaptive radiations, and the role of functional innovation and adaptation as drivers of both micro- and macroevolution. Yet analysis of function in extinct animals is fraught with difficulty. Hypotheses that interpret molariform teeth in fishes as evidence of durophagous (shell-crushing) diets provide a good example of the particular problems inherent in the methods of functional morphology. This is because the assumed close coupling of form and function upon which the approach is based is weakened by, among other things, behavioural flexibility and the absence of a clear one to one relationship between structures and functions. Here we show that ISO 25178-2 standard parameters for surface texture, derived from analysis of worn surfaces of molariform teeth of fishes, vary significantly between species that differ in the amount of hard-shelled prey they consume. Two populations of the Sheepshead Seabream (Archosargus probatocephalus) were studied. This fish is not a dietary specialist, and one of the populations is known to consume more vegetation and less hard-shelled prey than the other; this is reflected in significant differences in their microwear textures. The Archosargus populations differ significantly in their microwear from the specialist shell-crusher Anarhichas lupus (the Atlantic Wolffish). Multivariate analysis of these three groups of fishes lends further support to the relationship between diet and tooth microwear, and provides robust validation of the approach. Application of the multivariate models derived from microwear texture in Archosargus and Anarhichas to a third fish species—the cichlid Astatoreochromis alluaudi—successfully separates wild caught fish that ate hard-shelled prey from lab-raised fish that did not. This cross-taxon validation demonstrates that quantitative analysis of tooth microwear texture can

  5. 3D tooth microwear texture analysis in fishes as a test of dietary hypotheses of durophagy

    International Nuclear Information System (INIS)

    Purnell, Mark A; Darras, Laurent P G

    2016-01-01

    An understanding of how extinct animals functioned underpins our understanding of past evolutionary events, including adaptive radiations, and the role of functional innovation and adaptation as drivers of both micro- and macroevolution. Yet analysis of function in extinct animals is fraught with difficulty. Hypotheses that interpret molariform teeth in fishes as evidence of durophagous (shell-crushing) diets provide a good example of the particular problems inherent in the methods of functional morphology. This is because the assumed close coupling of form and function upon which the approach is based is weakened by, among other things, behavioural flexibility and the absence of a clear one to one relationship between structures and functions. Here we show that ISO 25178-2 standard parameters for surface texture, derived from analysis of worn surfaces of molariform teeth of fishes, vary significantly between species that differ in the amount of hard-shelled prey they consume. Two populations of the Sheepshead Seabream (Archosargus probatocephalus) were studied. This fish is not a dietary specialist, and one of the populations is known to consume more vegetation and less hard-shelled prey than the other; this is reflected in significant differences in their microwear textures. The Archosargus populations differ significantly in their microwear from the specialist shell-crusher Anarhichas lupus (the Atlantic Wolffish). Multivariate analysis of these three groups of fishes lends further support to the relationship between diet and tooth microwear, and provides robust validation of the approach. Application of the multivariate models derived from microwear texture in Archosargus and Anarhichas to a third fish species—the cichlid Astatoreochromis alluaudi—successfully separates wild caught fish that ate hard-shelled prey from lab-raised fish that did not. This cross-taxon validation demonstrates that quantitative analysis of tooth microwear texture can

  6. ''Textural analysis of multiparametric MRI detects transition zone prostate cancer''

    Energy Technology Data Exchange (ETDEWEB)

    Sidhu, Harbir S.; Johnston, Edward W.; Taylor, Stuart A.; Halligan, Steve [Centre for Medical Imaging, University College London, London (United Kingdom); University College London Hospitals NHS Foundation Trust, London (United Kingdom); Benigno, Salvatore; Dikaios, Nikos [Centre for Medical Imaging, University College London, London (United Kingdom); Ganeshan, Balaji [Institute of Nuclear Medicine, University College London, University College Hospital, London (United Kingdom); Allen, Clare; Kirkham, Alex [University College London Hospitals NHS Foundation Trust, London (United Kingdom); Groves, Ashley M. [University College London Hospitals NHS Foundation Trust, London (United Kingdom); Institute of Nuclear Medicine, University College London, University College Hospital, London (United Kingdom); Ahmed, Hashim U.; Emberton, Mark [University College London Hospitals NHS Foundation Trust, London (United Kingdom); University College London, Research Department of Urology, London (United Kingdom); Punwani, Shonit [Centre for Medical Imaging, University College London, London (United Kingdom); University College London Hospitals NHS Foundation Trust, London (United Kingdom); Centre for Medical Imaging, University College London and University College London Hospitals NIHR Biomedical Research Centre, London (United Kingdom)

    2017-06-15

    To evaluate multiparametric-MRI (mpMRI) derived histogram textural-analysis parameters for detection of transition zone (TZ) prostatic tumour. Sixty-seven consecutive men with suspected prostate cancer underwent 1.5T mpMRI prior to template-mapping-biopsy (TPM). Twenty-six men had 'significant' TZ tumour. Two radiologists in consensus matched TPM to the single axial slice best depicting tumour, or largest TZ diameter for those with benign histology, to define single-slice whole TZ-regions-of-interest (ROIs). Textural-parameter differences between single-slice whole TZ-ROI containing significant tumour versus benign/insignificant tumour were analysed using Mann Whitney U test. Diagnostic accuracy was assessed by receiver operating characteristic area under curve (ROC-AUC) analysis cross-validated with leave-one-out (LOO) analysis. ADC kurtosis was significantly lower (p < 0.001) in TZ containing significant tumour with ROC-AUC 0.80 (LOO-AUC 0.78); the difference became non-significant following exclusion of significant tumour from single-slice whole TZ-ROI (p = 0.23). T1-entropy was significantly lower (p = 0.004) in TZ containing significant tumour with ROC-AUC 0.70 (LOO-AUC 0.66) and was unaffected by excluding significant tumour from TZ-ROI (p = 0.004). Combining these parameters yielded ROC-AUC 0.86 (LOO-AUC 0.83). Textural features of the whole prostate TZ can discriminate significant prostatic cancer through reduced kurtosis of the ADC-histogram where significant tumour is included in TZ-ROI and reduced T1 entropy independent of tumour inclusion. (orig.)

  7. Measurement and analysis of field-induced crystallographic texture using curved position-sensitive diffraction detectors

    DEFF Research Database (Denmark)

    Simons, Hugh; Daniels, John E.; Studer, Andrew J.

    2014-01-01

    This paper outlines measurement and analysis methodologies created for determining the structural responses of electroceramics to an electric field. A sample stage is developed to apply electric fields to ceramic materials at elevated temperatures during neutron diffraction experiments. The tested...... employing a curved positive sensitive detector. Methodologies are proposed to account for the geometrical effects when vector fields are applied to textured materials with angularly dispersive detector geometries. Representative results are presented for the ferroelectric (Bi1/2Na1/2)TiO3-6%BaTiO3 (BNT-6BT...

  8. MRI Texture Analysis Reflects Histopathology Parameters in Thyroid Cancer – A First Preliminary Study

    Directory of Open Access Journals (Sweden)

    Hans-Jonas Meyer

    2017-12-01

    Full Text Available OBJECT: Thyroid cancer represents the most frequent malignancy of the endocrine system with an increasing incidence worldwide. Novel imaging techniques are able to further characterize tumors and even predict histopathology features. Texture analysis is an emergent imaging technique to extract extensive data from an radiology images. The present study was therefore conducted to identify possible associations between texture analysis and histopathology parameters in thyroid cancer. METHODS: The radiological database was retrospectively reviewed for thyroid carcinoma. Overall, 13 patients (3 females, 23.1% with a mean age of 61.6 years were identified. The MaZda program was used for texture analysis. The T1-precontrast and T2-weighted images were analyzed and overall 279 texture feature for each sequence was investigated. For every patient cell count, Ki67-index and p53 count were investigated. RESULTS: Several significant correlations between texture features and histopathology were identified. Regarding T1-weighted images, S(0;1Sum Averg correlated the most with cell count (r = 0.82. An inverse correlations with S(5;0AngScMom, S(5;0DifVarnc S(5;0, DiffEntrp and GrNonZeros (r = −0.69, −0.66, −0.69 and −0.63, respectively was also identified. For T2-weighted images, Variance with r = 0.63 was the highest coefficient, WavEnLL_S3 correlated inversely with cell count (r = −0.57. WavEnLL_S2 derived from T1-weighted images was the highest coefficient r = −0.80, S(0;5SumVarnc was positively with r = 0.74. Regarding T2-weighted images WavEnHL_s-1 was inverse correlated with Ki67 index (r = −0.77. S(1;0Correlat was with r = 0.75 the best correlation with Ki67 index. For T1-weighed images S(5;0SumofSqs was the best with r = 0.65 with p53 count. For T2-weighted images S(1;−1SumEntrp was the inverse correlation with r = −0.72, whereas S(0;4AngScMom correlated positively with r = 0.63. CONCLUSIONS: MRI texture analysis

  9. Spectral analysis of the stick-slip phenomenon in "oral" tribological texture evaluation.

    Science.gov (United States)

    Sanahuja, Solange; Upadhyay, Rutuja; Briesen, Heiko; Chen, Jianshe

    2017-08-01

    "Oral" tribology has become a new paradigm in food texture studies to understand complex texture attributes, such as creaminess, oiliness, and astringency, which could not be successfully characterized by traditional texture analysis nor by rheology. Stick-slip effects resulting from intermittent sliding motion during kinetic friction of oral mucosa could constitute an additional determining factor of sensory perception where traditional friction coefficient values and their Stribeck regimes fail in predicting different lubricant (food bolus and saliva) behaviors. It was hypothesized that the observed jagged behavior of most sliding force curves are due to stick-slip effects and depend on test velocity, normal load, surface roughness as well as lubricant type. Therefore, different measurement set-ups were investigated: sliding velocities from 0.01 to 40 mm/s, loads of 0.5 and 2.5 N as well as a smooth and a textured silicone contact surface. Moreover, dry contact measurements were compared to model food systems, such as water, oil, and oil-in-water emulsions. Spectral analysis permitted to extract the distribution of stick-slip magnitudes for specific wave numbers, characterizing the occurrence of jagged force peaks per unit sliding distance, similar to frequencies per unit time. The spectral features were affected by all the above mentioned tested factors. Stick-slip created vibration frequencies in the range of those detected by oral mechanoreceptors (0.3-400 Hz). The study thus provides a new insight into the use of tribology in food psychophysics. Dynamic spectral analysis has been applied for the first time to the force-displacement curves in "oral" tribology. Analyzing the stick-slip phenomenon in the dynamic friction provides new information that is generally overlooked or confused with machine noise and which may help to understand friction-related sensory attributes. This approach allows us to differentiate samples that have similar friction coefficient

  10. Advanced measurement and analysis of surface textures produced by micro-machining processes

    International Nuclear Information System (INIS)

    Bordatchev, Evgueni V; Hafiz, Abdullah M K

    2014-01-01

    Surface texture of a part or a product has significant effects on its functionality, physical-mechanical properties and visual appearance. In particular for miniature products, the implication of surface quality becomes critical owing to the presence of geometrical features with micro/nano-scale dimensions. Qualitative and quantitative assessments of surface texture are carried out predominantly by profile parameters, which are often insufficient to address the contribution of constituent spatial components with varied amplitudes and wavelengths. In this context, this article presents a novel approach for advanced measurement and analysis of profile average roughness (R a ) and its spatial distribution at different wavelength intervals. The applicability of the proposed approach was verified for three different surface topographies prepared by grinding, laser micro-polishing and micro-milling processes. From the measurement and analysis results, R a (λ) spatial distribution was found to be an effective measure of revealing the contributions of various spatial components within specific wavelength intervals towards formation of the entire surface profile. In addition, the approach was extended to the measurement and analysis of areal average roughness S a (λ) spatial distribution within different wavelength intervals. Besides, the proposed method was demonstrated to be a useful technique in developing a functional correlation between a manufacturing process and its corresponding surface profile. (paper)

  11. Personal recognition using finger knuckle shape oriented features and texture analysis

    Directory of Open Access Journals (Sweden)

    K. Usha

    2016-10-01

    Full Text Available Finger knuckle print is considered as one of the emerging hand biometric traits due to its potentiality toward the identification of individuals. This paper contributes a new method for personal recognition using finger knuckle print based on two approaches namely, geometric and texture analyses. In the first approach, the shape oriented features of the finger knuckle print are extracted by means of angular geometric analysis and then integrated to achieve better precision rate. Whereas, the knuckle texture feature analysis is carried out by means of multi-resolution transform known as Curvelet transform. This Curvelet transform has the ability to approximate curved singularities with minimum number of Curvelet coefficients. Since, finger knuckle patterns mainly consist of lines and curves, Curvelet transform is highly suitable for its representation. Further, the Curvelet transform decomposes the finger knuckle image into Curvelet sub-bands which are termed as ‘Curvelet knuckle’. Finally, principle component analysis is applied on each Curvelet knuckle for extracting its feature vector through the covariance matrix derived from their Curvelet coefficients. Extensive experiments were conducted using PolyU database and IIT finger knuckle database. The experimental results confirm that, our proposed method shows a high recognition rate of 98.72% with lower false acceptance rate of 0.06%.

  12. Assessment of textural differentiations in forest resources in Romania using fractal analysis

    DEFF Research Database (Denmark)

    Andronache, Ion; Fensholt, Rasmus; Ahammer, Helmut

    2017-01-01

    regions in Romania affected by both deforestation and reforestation using a non-Euclidean method based on fractal analysis.We calculated four fractal dimensions of forest areas: the fractal box-counting dimension of the forest areas, the fractal box-counting dimension of the dilated forest areas......, the fractal dilation dimension and the box-counting dimension of the border of the dilated forest areas. Fractal analysis revealed morpho-structural and textural differentiations of forested, deforested and reforested areas in development regions with dominant mountain relief and high hills (more forested...... and compact organization) in comparison to the development regions dominated by plains or low hills (less forested, more fragmented with small and isolated clusters). Our analysis used the fractal analysis that has the advantage of analyzing the entire image, rather than studying local information, thereby...

  13. Use of digital image analysis combined with fractal theory to determine particle morphology and surface texture of quartz sands

    Directory of Open Access Journals (Sweden)

    Georgia S. Araujo

    2017-12-01

    Full Text Available The particle morphology and surface texture play a major role in influencing mechanical and hydraulic behaviors of sandy soils. This paper presents the use of digital image analysis combined with fractal theory as a tool to quantify the particle morphology and surface texture of two types of quartz sands widely used in the region of Vitória, Espírito Santo, southeast of Brazil. The two investigated sands are sampled from different locations. The purpose of this paper is to present a simple, straightforward, reliable and reproducible methodology that can identify representative sandy soil texture parameters. The test results of the soil samples of the two sands separated by sieving into six size fractions are presented and discussed. The main advantages of the adopted methodology are its simplicity, reliability of the results, and relatively low cost. The results show that sands from the coastal spit (BS have a greater degree of roundness and a smoother surface texture than river sands (RS. The values obtained in the test are statistically analyzed, and again it is confirmed that the BS sand has a slightly greater degree of sphericity than that of the RS sand. Moreover, the RS sand with rough surface texture has larger specific surface area values than the similar BS sand, which agree with the obtained roughness fractal dimensions. The consistent experimental results demonstrate that image analysis combined with fractal theory is an accurate and efficient method to quantify the differences in particle morphology and surface texture of quartz sands.

  14. A Framework for Establishing Standard Reference Scale of Texture by Multivariate Statistical Analysis Based on Instrumental Measurement and Sensory Evaluation.

    Science.gov (United States)

    Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye

    2016-01-13

    A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.

  15. Texture Based Quality Analysis of Simulated Synthetic Ultrasound Images Using Local Binary Patterns †

    Directory of Open Access Journals (Sweden)

    Prerna Singh

    2017-12-01

    Full Text Available Speckle noise reduction is an important area of research in the field of ultrasound image processing. Several algorithms for speckle noise characterization and analysis have been recently proposed in the area. Synthetic ultrasound images can play a key role in noise evaluation methods as they can be used to generate a variety of speckle noise models under different interpolation and sampling schemes, and can also provide valuable ground truth data for estimating the accuracy of the chosen methods. However, not much work has been done in the area of modeling synthetic ultrasound images, and in simulating speckle noise generation to get images that are as close as possible to real ultrasound images. An important aspect of simulated synthetic ultrasound images is the requirement for extensive quality assessment for ensuring that they have the texture characteristics and gray-tone features of real images. This paper presents texture feature analysis of synthetic ultrasound images using local binary patterns (LBP and demonstrates the usefulness of a set of LBP features for image quality assessment. Experimental results presented in the paper clearly show how these features could provide an accurate quality metric that correlates very well with subjective evaluations performed by clinical experts.

  16. Subacute and Chronic Left Ventricular Myocardial Scar: Accuracy of Texture Analysis on Nonenhanced Cine MR Images.

    Science.gov (United States)

    Baessler, Bettina; Mannil, Manoj; Oebel, Sabrina; Maintz, David; Alkadhi, Hatem; Manka, Robert

    2018-01-01

    Purpose To test whether texture analysis (TA) allows for the diagnosis of subacute and chronic myocardial infarction (MI) on noncontrast material-enhanced cine cardiac magnetic resonance (MR) images. Materials and Methods In this retrospective, institutional review board-approved study, 120 patients who underwent cardiac MR imaging and showed large transmural (volume of enhancement on late gadolinium enhancement [LGE] images >20%, n = 72) or small (enhanced volume ≤20%, n = 48) subacute or chronic ischemic scars were included. Sixty patients with normal cardiac MR imaging findings served as control subjects. Regions of interest for TA encompassing the left ventricle were drawn by two blinded, independent readers on cine images in end systole by using a freely available software package. Stepwise dimension reduction and texture feature selection based on reproducibility, machine learning, and correlation analyses were performed for selecting features, enabling the diagnosis of MI on nonenhanced cine MR images by using LGE imaging as the standard of reference. Results Five independent texture features allowed for differentiation between ischemic scar and normal myocardium on cine MR images in both subgroups: Teta1, Perc.01, Variance, WavEnHH.s-3, and S(5,5)SumEntrp (in patients with large MI: all P values cine MR images, with an area under the curve of 0.93 and 0.92, respectively. Conclusion This proof-of-concept study indicates that TA of nonenhanced cine MR images allows for the diagnosis of subacute and chronic MI with high accuracy. © RSNA, 2017 Online supplemental material is available for this article.

  17. Texture analysis of MR images of patients with Mild Traumatic Brain Injury

    International Nuclear Information System (INIS)

    Holli, Kirsi K; Harrison, Lara; Dastidar, Prasun; Wäljas, Minna; Liimatainen, Suvi; Luukkaala, Tiina; Öhman, Juha; Soimakallio, Seppo; Eskola, Hannu

    2010-01-01

    Our objective was to study the effect of trauma on texture features in cerebral tissue in mild traumatic brain injury (MTBI). Our hypothesis was that a mild trauma may cause microstructural changes, which are not necessarily perceptible by visual inspection but could be detected with texture analysis (TA). We imaged 42 MTBI patients by using 1.5 T MRI within three weeks of onset of trauma. TA was performed on the area of mesencephalon, cerebral white matter at the levels of mesencephalon, corona radiata and centrum semiovale and in different segments of corpus callosum (CC) which have been found to be sensitive to damage. The same procedure was carried out on a control group of ten healthy volunteers. Patients' TA data was compared with the TA results of the control group comparing the amount of statistically significantly differing TA parameters between the left and right sides of the cerebral tissue and comparing the most discriminative parameters. There were statistically significant differences especially in several co-occurrence and run-length matrix based parameters between left and right side in the area of mesencephalon, in cerebral white matter at the level of corona radiata and in the segments of CC in patients. Considerably less difference was observed in the healthy controls. TA revealed significant changes in texture parameters of cerebral tissue between hemispheres and CC segments in TBI patients. TA may serve as a novel additional tool for detecting the conventionally invisible changes in cerebral tissue in MTBI and help the clinicians to make an early diagnosis

  18. Symmetric textures

    International Nuclear Information System (INIS)

    Ramond, P.

    1993-01-01

    The Wolfenstein parametrization is extended to the quark masses in the deep ultraviolet, and an algorithm to derive symmetric textures which are compatible with existing data is developed. It is found that there are only five such textures

  19. Glaucoma Monitoring in a Clinical Setting Glaucoma Progression Analysis vs Nonparametric Progression Analysis in the Groningen Longitudinal Glaucoma Study

    NARCIS (Netherlands)

    Wesselink, Christiaan; Heeg, Govert P.; Jansonius, Nomdo M.

    Objective: To compare prospectively 2 perimetric progression detection algorithms for glaucoma, the Early Manifest Glaucoma Trial algorithm (glaucoma progression analysis [GPA]) and a nonparametric algorithm applied to the mean deviation (MD) (nonparametric progression analysis [NPA]). Methods:

  20. Surface Textural Analysis of Quartz Grains from Modern Point Bar Deposits in Lower Reaches of the Yellow River

    Science.gov (United States)

    Cheng, Yong; Liu, Cong; Lu, Ping; Zhang, Yu; Nie, Qi; Wen, Yiming

    2018-01-01

    The surfaces of quartz grains contain characteristic textures formed during the process of transport, due to their stable physical and chemical properties. The surface textures include the information about source area, transporting force, sedimentary environment and evolution history of sediment. Surface textures of quartz grains from modern point bar deposits in the lower reaches of the Yellow River are observed and studied by scanning electron microscopy (SEM). Results indicate that there are 22 kinds of surface textures. The overall surface morphology of quartz grains shows short transporting time and distance and weak abrasive action of the river water. The combined surface textures caused by mechanical action indicate that quartz grains are transporting in a high-energy hydrodynamic condition and suffer a strong mechanical impact and abrasion. The common solution pits prove that the chemical property of transportation medium is very active and quartz grains receive an obvious chemical action. The combination of these surface textures can be an identification mark of fluvial environment, and that is: quartz grains are main subangular outline, whose roundness is higher with the farther motion distance; Surface fluctuation degree of quartz grains is relatively high, and gives priority to high and medium relief; V-shaped percussion marks are very abundant caused by mechanical action; The conchoidal of different sizes and steps are common-developed with paragenesis relationship; Solution pits are common-developed as well. The study makes up for the blank of surface textures analysis of quartz grains from modern fluvial deposits in China. It provides new ideas and evidence for studies of the sedimentary process and environmental significance, although the deep meanings of these micro textures remain to be further researched.

  1. Can Laws Be a Potential PET Image Texture Analysis Approach for Evaluation of Tumor Heterogeneity and Histopathological Characteristics in NSCLC?

    Science.gov (United States)

    Karacavus, Seyhan; Yılmaz, Bülent; Tasdemir, Arzu; Kayaaltı, Ömer; Kaya, Eser; İçer, Semra; Ayyıldız, Oguzhan

    2018-04-01

    We investigated the association between the textural features obtained from 18 F-FDG images, metabolic parameters (SUVmax , SUVmean, MTV, TLG), and tumor histopathological characteristics (stage and Ki-67 proliferation index) in non-small cell lung cancer (NSCLC). The FDG-PET images of 67 patients with NSCLC were evaluated. MATLAB technical computing language was employed in the extraction of 137 features by using first order statistics (FOS), gray-level co-occurrence matrix (GLCM), gray-level run length matrix (GLRLM), and Laws' texture filters. Textural features and metabolic parameters were statistically analyzed in terms of good discrimination power between tumor stages, and selected features/parameters were used in the automatic classification by k-nearest neighbors (k-NN) and support vector machines (SVM). We showed that one textural feature (gray-level nonuniformity, GLN) obtained using GLRLM approach and nine textural features using Laws' approach were successful in discriminating all tumor stages, unlike metabolic parameters. There were significant correlations between Ki-67 index and some of the textural features computed using Laws' method (r = 0.6, p = 0.013). In terms of automatic classification of tumor stage, the accuracy was approximately 84% with k-NN classifier (k = 3) and SVM, using selected five features. Texture analysis of FDG-PET images has a potential to be an objective tool to assess tumor histopathological characteristics. The textural features obtained using Laws' approach could be useful in the discrimination of tumor stage.

  2. Surface inspection of flat products by means of texture analysis: on-line implementation using neural networks

    Science.gov (United States)

    Fernandez, Carlos; Platero, Carlos; Campoy, Pascual; Aracil, Rafael

    1994-11-01

    This paper describes some texture-based techniques that can be applied to quality assessment of flat products continuously produced (metal strips, wooden surfaces, cork, textile products, ...). Since the most difficult task is that of inspecting for product appearance, human-like inspection ability is required. A common feature to all these products is the presence of non- deterministic texture on their surfaces. Two main subjects are discussed: statistical techniques for both surface finishing determination and surface defect analysis as well as real-time implementation for on-line inspection in high-speed applications. For surface finishing determination a Gray Level Difference technique is presented to perform over low resolution images, that is, no-zoomed images. Defect analysis is performed by means of statistical texture analysis over defective portions of the surface. On-line implementation is accomplished by means of neural networks. When a defect arises, textural analysis is applied which result in a data-vector, acting as input of a neural net, previously trained in a supervised way. This approach tries to reach on-line performance in automated visual inspection applications when texture is presented in flat product surfaces.

  3. Progress of electromagnetic analysis for fusion reactors

    International Nuclear Information System (INIS)

    Takagi, T.; Ruatto, P.; Boccaccini, L.V.

    1998-01-01

    This paper describes the recent progress of electromagnetic analysis research for fusion reactors including methods, codes, verification tests and some applications. Due to the necessity of the research effort for the structural design of large tokamak devices since the 1970's with the help of the introduction of new numerical methods and the advancement of computer technologies, three-dimensional analysis methods have become as practical as shell approximation methods. The electromagnetic analysis is now applied to the structural design of new fusion reactors. Some more modeling and verification tests are necessary when the codes are applied to new materials with nonlinear material properties. (orig.)

  4. Characterising the disintegration properties of tablets in opaque media using texture analysis.

    Science.gov (United States)

    Scheuerle, Rebekah L; Gerrard, Stephen E; Kendall, Richard A; Tuleu, Catherine; Slater, Nigel K H; Mahbubani, Krishnaa T

    2015-01-01

    Tablet disintegration characterisation is used in pharmaceutical research, development, and quality control. Standard methods used to characterise tablet disintegration are often dependent on visual observation in measurement of disintegration times. This presents a challenge for disintegration studies of tablets in opaque, physiologically relevant media that could be useful for tablet formulation optimisation. This study has explored an application of texture analysis disintegration testing, a non-visual, quantitative means of determining tablet disintegration end point, by analysing the disintegration behaviour of two tablet formulations in opaque media. In this study, the disintegration behaviour of one tablet formulation manufactured in-house, and Sybedia Flashtab placebo tablets in water, bovine, and human milk were characterised. A novel method is presented to characterise the disintegration process and to quantify the disintegration end points of the tablets in various media using load data generated by a texture analyser probe. The disintegration times in the different media were found to be statistically different (Pdisintegration times from each other in human versus bovine milk (adjusted P value 0.1685). Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Automatic Segmenting Structures in MRI's Based on Texture Analysis and Fuzzy Logic

    Science.gov (United States)

    Kaur, Mandeep; Rattan, Munish; Singh, Pushpinder

    2017-12-01

    The purpose of this paper is to present the variational method for geometric contours which helps the level set function remain close to the sign distance function, therefor it remove the need of expensive re-initialization procedure and thus, level set method is applied on magnetic resonance images (MRI) to track the irregularities in them as medical imaging plays a substantial part in the treatment, therapy and diagnosis of various organs, tumors and various abnormalities. It favors the patient with more speedy and decisive disease controlling with lesser side effects. The geometrical shape, the tumor's size and tissue's abnormal growth can be calculated by the segmentation of that particular image. It is still a great challenge for the researchers to tackle with an automatic segmentation in the medical imaging. Based on the texture analysis, different images are processed by optimization of level set segmentation. Traditionally, optimization was manual for every image where each parameter is selected one after another. By applying fuzzy logic, the segmentation of image is correlated based on texture features, to make it automatic and more effective. There is no initialization of parameters and it works like an intelligent system. It segments the different MRI images without tuning the level set parameters and give optimized results for all MRI's.

  6. Texture analysis of trabecular bone using conventional radiographs: medical imaging and osteoporosis

    International Nuclear Information System (INIS)

    Karunanithi, R.; Panicker, T.M.R.; Paul Korath, M.; Jagadeesan, K.; Ganesan, S.

    2008-01-01

    Osteoporosis is characterized by reduced bone mass, microstructural deterioration with advancing age, and an increase in fracture risk. The accurate clinical assessment of bone strength and fracture risk is important for management of bone loss diseases such as osteoporosis risk. From a clinical point of view, microarchitecture is an interesting aspect to study and define patterns of bone alterations with aging and pathology. Microarchitecture seems to be a determinant of bone fragility independent of bone density. Moreover, bone microarchitecture seems to be important to understand the mechanisms of bone fragility independent of bone density. Moreover bone microarchitecture seems to be important to understand the mechanisms of bone fragility as well as the action of the drugs used to prevent osteoporotic fractures. In the case of osteoporosis the bone texture of the trabecular network as it appears on the plain radiographs can be quantified by applying image processing tools. Among the factors conditioning bone strength and osteoporotic fractures, bone mineral density is the most important and the best studied. Though, other factors also play a role: macroarchitecture of bones, cortical thickness, quality of bone crystal and of collagen network and trabecular microarchitecture. The microarchitecture plays a major role, and is an aspect of the definition of osteoporosis. Therefore, it would be very helpful if these alterations could be measured in addition to bone mineral density with noninvasive techniques, such as radiographs, and to assess the status of the bone by texture analysis

  7. MRI Texture Analysis Reveals Deep Gray Nuclei Damage in Amyotrophic Lateral Sclerosis.

    Science.gov (United States)

    de Albuquerque, Milena; Anjos, Lara G V; Maia Tavares de Andrade, Helen; de Oliveira, Márcia S; Castellano, Gabriela; Junqueira Ribeiro de Rezende, Thiago; Nucci, Anamarli; França Junior, Marcondes Cavalcante

    2016-01-01

    Amyotrophic Lateral Sclerosis (ALS) is characterized by extensive corticospinal damage, but extrapyramidal involvement is suggested in pathological studies. Texture analysis (TA) is an image processing technique that evaluates the distribution of gray levels between pixels in a given region of interest (ROI). It provides quantitative data and has been employed in several neurodegenerative disorders. Here, we used TA to investigate possible deep gray nuclei (DGN) abnormalities in a cohort of ALS patients. Thirty-two ALS patients and 32 healthy controls underwent MRI in a 3T scanner. The T1 volumetric sequence was used for DGN segmentation and extraction of 11 texture parameters using the MaZda software. Statistical analyses were performed using the Mann-Whitney non-parametric test, with a significance level set at α = 0.025 (FDR-corrected) for TA. Patients had significantly higher values for the parameter correlation (CO) in both thalami and in the right caudate nucleus compared to healthy controls. Also, the parameter Inverse Difference Moment or Homogeneity (IDM) presented significantly smaller values in the ALS group in both thalami. TA of T1 weighted images revealed DGN alterations in patients with ALS, namely in the thalami and caudate nuclei. Copyright © 2015 by the American Society of Neuroimaging.

  8. Automated kidney morphology measurements from ultrasound images using texture and edge analysis

    Science.gov (United States)

    Ravishankar, Hariharan; Annangi, Pavan; Washburn, Michael; Lanning, Justin

    2016-04-01

    In a typical ultrasound scan, a sonographer measures Kidney morphology to assess renal abnormalities. Kidney morphology can also help to discriminate between chronic and acute kidney failure. The caliper placements and volume measurements are often time consuming and an automated solution will help to improve accuracy, repeatability and throughput. In this work, we developed an automated Kidney morphology measurement solution from long axis Ultrasound scans. Automated kidney segmentation is challenging due to wide variability in kidney shape, size, weak contrast of the kidney boundaries and presence of strong edges like diaphragm, fat layers. To address the challenges and be able to accurately localize and detect kidney regions, we present a two-step algorithm that makes use of edge and texture information in combination with anatomical cues. First, we use an edge analysis technique to localize kidney region by matching the edge map with predefined templates. To accurately estimate the kidney morphology, we use textural information in a machine learning algorithm framework using Haar features and Gradient boosting classifier. We have tested the algorithm on 45 unseen cases and the performance against ground truth is measured by computing Dice overlap, % error in major and minor axis of kidney. The algorithm shows successful performance on 80% cases.

  9. A multi-topographical-instrument analysis: the breast implant texture measurement

    Science.gov (United States)

    Garabédian, Charles; Delille, Rémi; Deltombe, Raphaël; Anselme, Karine; Atlan, Michael; Bigerelle, Maxence

    2017-06-01

    Capsular contracture is a major complication after implant-based breast augmentation. To address this tissue reaction, most manufacturers texture the outer breast implant surfaces with calibrated salt grains. However, the analysis of these surfaces on sub-micron scales has been under-studied. This scale range is of interest to understand the future of silicone particles potentially released from the implant surface and the aetiology of newly reported complications, such as Anaplastic Large Cell Lymphoma. The surface measurements were accomplished by tomography and by two optical devices based on interferometry and on focus variation. The robustness of the measurements was investigated from the tissue scale to the cellular scale. The macroscopic pore-based structure of the textured implant surfaces is consistently measured by the three instruments. However, the multi-scale analyses start to be discrepant in a scale range between 50 µm and 500 µm characteristic of a finer secondary roughness regardless of the pore shape. The focus variation and the micro-tomography would fail to capture this roughness regime because of a focus-related optical artefact and of step-shaped artefact respectively.

  10. Usefulness of texture analysis in differentiating transient from persistent part-solid nodules(PSNs: a retrospective study.

    Directory of Open Access Journals (Sweden)

    Sang Hwan Lee

    Full Text Available BACKGROUND: Early discrimination between transient and persistent par-solid ground-glass nodules (PSNs at CT is essential for patient management. The objective of our study was to retrospectively investigate the value of texture analysis in differentiating pulmonary transient and persistent PSNs in addition to clinical and CT features. METHODS: This retrospective study was performed with IRB approval and a waiver of the requirement for patients' informed consent. From January 2007 to October 2009, we identified 77 individuals (39 men and 38 women; mean age, 55 years with 86 PSNs on thin-section chest CT. Thirty-nine PSNs in 31 individuals were transient and 47 PSNs in 46 patients were persistent. The clinical, CT, and texture features of PSNs were evaluated. To investigate the additional value of texture analysis in differentiating transient from persistent PSNs, logistic regression analysis and C-statistics were performed. RESULTS: Between transient and persistent PSNs, there were significant differences in age, gender, smoking history, and eosinophil count among the clinical features. As for thin-section CT features, there were significant differences in lesion size, solid portion size, and lesion multiplicity. In terms of texture features, there were significant differences in mean attenuation, skewness of whole PSN, attenuation ratio of whole PSN to inner solid portion, and 5-, 10-, 25-, 50-percentile CT numbers of whole PSN. Multivariate analysis revealed eosinophilia, lesion size, lesion multiplicity, mean attenuation of whole PSN, skewness of whole PSN, and 5-percentile CT number were significant independent predictors of transient PSNs. (P<0.05 C-statistics revealed that texture analysis incorporating clinical and CT features (AUC, 92.9% showed significantly higher differentiating performance of transient from persistent PSNs compared with the clinical and CT features alone (AUC, 79.0%. (P =  0.004. CONCLUSION: Texture analysis of

  11. Evolutionary Game Theory Analysis of Tumor Progression

    Science.gov (United States)

    Wu, Amy; Liao, David; Sturm, James; Austin, Robert

    2014-03-01

    Evolutionary game theory applied to two interacting cell populations can yield quantitative prediction of the future densities of the two cell populations based on the initial interaction terms. We will discuss how in a complex ecology that evolutionary game theory successfully predicts the future densities of strains of stromal and cancer cells (multiple myeloma), and discuss the possible clinical use of such analysis for predicting cancer progression. Supported by the National Science Foundation and the National Cancer Institute.

  12. CT Texture Analysis of Ex Vivo Renal Stones Predicts Ease of Fragmentation with Shockwave Lithotripsy.

    Science.gov (United States)

    Cui, Helen W; Devlies, Wout; Ravenscroft, Samuel; Heers, Hendrik; Freidin, Andrew J; Cleveland, Robin O; Ganeshan, Balaji; Turney, Benjamin W

    2017-07-01

    Understanding the factors affecting success of extracorporeal shockwave lithotripsy (SWL) would improve informed decision-making on the most appropriate treatment modality for an individual patient. Although stone size and skin-to-stone distance do correlate with fragmentation efficacy, it has been shown that stone composition and architecture, as reflected by structural heterogeneity on CT, are also important factors. This study aims to determine if CT texture analysis (CTTA), a novel, nondestructive, and objective tool that generates statistical metrics reflecting stone heterogeneity, could have utility in predicting likelihood of SWL success. Seven spontaneously passed, intact renal tract stones, were scanned ex vivo using standard CT KUB and micro-CT. The stones were then fragmented in vitro using a clinical lithotripter, after which, chemical composition analysis was performed. CTTA was used to generate a number of metrics that were correlated to the number of shocks needed to fragment the stone. CTTA metrics reflected stone characteristics and composition, and predicted ease of SWL fragmentation. The strongest correlation with number of shocks required to fragment the stone was mean Hounsfield unit (HU) density (r = 0.806, p = 0.028) and a CTTA metric measuring the entropy of the pixel distribution of the stone image (r = 0.804, p = 0.039). Using multiple linear regression analysis, the best model showed that CTTA metrics of entropy and kurtosis could predict 92% of the outcome of number of shocks needed to fragment the stone. This was superior to using stone volume or density. CTTA metrics entropy and kurtosis have been shown in this experimental ex vivo setting to strongly predict fragmentation by SWL. This warrants further investigation in a larger clinical study for the contribution of CT textural metrics as a measure of stone heterogeneity, along with other known clinical factors, to predict likelihood of SWL success.

  13. RHEED transmission mode and pole figures thin film and nanostructure texture analysis

    CERN Document Server

    Wang, Gwo-Ching

    2014-01-01

    This unique book covers the fundamental principle of electron diffraction, basic instrumentation of RHEED, definitions of textures in thin films and nanostructures, mechanisms and control of texture formation, and examples of RHEED transmission mode measurements of texture and texture evolution of thin films and nanostructures. Also presented is a new application of RHEED in the transmission mode called RHEED pole figure technique that can be used to monitor the texture evolution in thin film growth and nanostructures and is not limited to single crystal epitaxial film growth. Details of the construction of RHEED pole figures and the interpretation of observed pole figures are presented.  Materials covered include metals, semiconductors, and thin insulators. This book also: Presents a new application of RHEED in the transmission mode Introduces a variety of textures from metals, semiconductors, compound semiconductors, and their characteristics in RHEED pole figures Provides examples of RHEED measurements o...

  14. Analysis of Crystallographic Textures in Aluminum Plates Processed by Equal Channel Angular Extrusion

    DEFF Research Database (Denmark)

    Li, Saiyi; Mishin, Oleg

    2014-01-01

    A modeling and experimental investigation has been conducted to explore the effect of processing route on texture evolution during equal channel angular extrusion (ECAE) of aluminum plate samples. It is found that although the textures in the plates develop along orientation fibers previously ide...... identified for ECAE-processed rods and bars, the main components and strength of these textures vary significantly with processing route, which may lead to considerable differences in the plastic anisotropy of the plates....

  15. Texture analysis of pulmonary parenchymateous changes related to pulmonary thromboembolism in dogs - a novel approach using quantitative methods

    DEFF Research Database (Denmark)

    Marschner, Clara Büchner; Kokla, Marietta; Amigo Rubio, Jose Manuel

    2017-01-01

    include dual energy computed tomography (DECT) as well as computer assisted diagnosis (CAD) techniques. The purpose of this study was to investigate the performance of quantitative texture analysis for detecting dogs with PTE using grey-level co-occurrence matrices (GLCM) and multivariate statistical...... classification analyses. CT images from healthy (n = 6) and diseased (n = 29) dogs with and without PTE confirmed on CTPA were segmented so that only tissue with CT numbers between −1024 and −250 Houndsfield Units (HU) was preserved. GLCM analysis and subsequent multivariate classification analyses were...... using GLCM is an effective tool for distinguishing healthy from abnormal lung. Furthermore the texture of pulmonary parenchyma in dogs with PTE is altered, when compared to the texture of pulmonary parenchyma of healthy dogs. The models’ poorer performance in classifying dogs within the diseased group...

  16. Utilization of Advanced Diagnostic Methods for Texture and Rut Depth Analysis on a Testing Pavement Section

    Directory of Open Access Journals (Sweden)

    Slabej Martin

    2015-05-01

    Full Text Available Qualitative characteristics of pavement in wide range reflects the pavement serviceability, which is a summary of the characteristics of the pavement, providing a fast, smooth, economical and especially safe driving of motor-vehicles. The target factor of pavement serviceability and safety of roads represents the quality of their surface properties. In the framework of research activities performed in the Research Centre founded under the auspices of University of Žilina, individual parameters of pavement serviceability were monitored by pavement surface scanning. This paper describes the creation of a 3D - road surface model and its analysis and evaluation from the viewpoint of two pavement serviceability parameters - the rut depth and texture. Measurements were performed on an experimental pavement section used contemporary in an Accelerated Pavement Testing experiment. The long-term goal is to ascertain functions predicting degradation of these two pavement serviceability parameters.

  17. Image-Based Three-Dimensional Analysis to Characterize the Texture of Porous Scaffolds

    Directory of Open Access Journals (Sweden)

    Diana Massai

    2014-01-01

    Full Text Available The aim of the present study is to characterize the microstructure of composite scaffolds for bone tissue regeneration containing different ratios of chitosan/gelatin blend and bioactive glasses. Starting from realistic 3D models of the scaffolds reconstructed from micro-CT images, the level of heterogeneity of scaffold architecture is evaluated performing a lacunarity analysis. The results demonstrate that the presence of the bioactive glass component affects not only macroscopic features such as porosity, but mainly scaffold microarchitecture giving rise to structural heterogeneity, which could have an impact on the local cell-scaffold interaction and scaffold performances. The adopted approach allows to investigate the scale-dependent pore distribution within the scaffold and the related structural heterogeneity features, providing a comprehensive characterization of the scaffold texture.

  18. Gender and age effects in structural brain asymmetry as measured by MRI texture analysis.

    Science.gov (United States)

    Kovalev, Vassili A; Kruggel, Frithjof; von Cramon, D Yves

    2003-07-01

    Effects of gender and age on structural brain asymmetry were studied by 3D texture analysis in 380 adults. Asymmetry is detected by comparing the complex 3D gray-scale image patterns in the left and right cerebral hemispheres as revealed by anatomical T1-weighted MRI datasets. The Talairach and Tournoux parcellation system was applied to study the asymmetry on five levels: the whole cerebrum, nine coronal sections, 12 axial sections, boxes resulting from both coronal and axial subdivisions, and by a sliding spherical window of 9 mm diameter. The analysis revealed that the brain asymmetry increases in the anterior-posterior direction starting from the central region onward. Male brains were found to be more asymmetric than female. This gender-related effect is noticeable in all brain areas but is most significant in the superior temporal gyrus, Heschl's gyrus, the adjacent white matter regions in the temporal stem and the knee of the optic radiation, the thalamus, and the posterior cingulate. The brain asymmetry increases significantly with age in the inferior frontal gyrus, anterior insula, anterior cingulate, parahippocampal gyrus, retrosplenial cortex, coronal radiata, and knee region of the internal capsule. Asymmetry decreases with age in the optic radiation, precentral gyrus, and angular gyrus. The texture-based method reported here is based on extended multisort cooccurrence matrices that employ intensity, gradient, and anisotropy features in a uniform way. It is sensitive, simple to reproduce, robust, and unbiased in the sense that segmentation of brain compartments and spatial transformations are not necessary. Thus, it should be considered as another tool for digital morphometry in neuroscience.

  19. Visualizing Organic Textures and Biosignatures: Analysis of the Deep Biosphere, Meteorites, and Mars

    Science.gov (United States)

    Bhartia, R.

    2017-12-01

    Understanding life in the subsurface offers a unique understanding of how we can search for potential biosignatures on Mars. The spatial distri- bution of communities in this nutrient limited envi- ronment can be co-located with mineral facies, associ- ated to morphological features, or bound to zones of high potential energy. Comparing these organic textures to abotically driven processes in meteorites, when coupled to characterization of the organic con- tent, spatial relationships to mineralogical and ele- mental textures, and morphology will aid in our under- standing of the likely provenance of organics on Mars. Often we approach biosignatures detection with an earth-centric perspective where we assume that extant or ancient life leaves behind visible indicators; either as pigments used to absorb energy from the sun/radiation, protectant from UV radiation, or as veri- gated mineral facies that may persist in the rock rec- ord. Our analysis of subsurface life, a region that is decoupled from the photozone (decoupled from photo- synthesis) and/or exists in a nutrient limited environ- ment, has shown that we need to capitalize on a wider range of the electromagnetic spectrum over multiple spatial scales to understand where microbial life may exist, how they make a living, and how/if their signa- tures will persist geological time. Similar to the approach of the NAI Life Under- ground program, the Mars 2020 project includes a suite of instruments operating over the meter to micrometer scale that will observe the surface (and near subsur- face) of Mars from gamma rays to the IR - a range where minerals and organics reflect, absorb, and vi- brate. More specifically, the combined capabilities of both SHERLOC (a deep UV Raman/fluorescence spectrometer) and PIXL (an X-ray fluorescence spectrometer), spatial maps of organics minerals and elements will be correlated to morphology and textures to assess potential biosignatures. We present here our results of a spectral

  20. Aboveground biomass mapping of African forest mosaics using canopy texture analysis: toward a regional approach.

    Science.gov (United States)

    Bastin, Jean-François; Barbier, Nicolas; Couteron, Pierre; Adams, Benoît; Shapiro, Aurélie; Bogaert, Jan; De Cannière, Charles

    textural analysis offer new opportunities to characterize the spatial and temporal variation of the structure of dense forests and may complement the toolbox used by tropical forest ecologists, managers or REDD+ national monitoring, reporting and verification bodies.

  1. Texture analysis of pulmonary parenchymateous changes related to pulmonary thromboembolism in dogs - a novel approach using quantitative methods.

    Science.gov (United States)

    Marschner, C B; Kokla, M; Amigo, J M; Rozanski, E A; Wiinberg, B; McEvoy, F J

    2017-07-11

    Diagnosis of pulmonary thromboembolism (PTE) in dogs relies on computed tomography pulmonary angiography (CTPA), but detailed interpretation of CTPA images is demanding for the radiologist and only large vessels may be evaluated. New approaches for better detection of smaller thrombi include dual energy computed tomography (DECT) as well as computer assisted diagnosis (CAD) techniques. The purpose of this study was to investigate the performance of quantitative texture analysis for detecting dogs with PTE using grey-level co-occurrence matrices (GLCM) and multivariate statistical classification analyses. CT images from healthy (n = 6) and diseased (n = 29) dogs with and without PTE confirmed on CTPA were segmented so that only tissue with CT numbers between -1024 and -250 Houndsfield Units (HU) was preserved. GLCM analysis and subsequent multivariate classification analyses were performed on texture parameters extracted from these images. Leave-one-dog-out cross validation and receiver operator characteristic (ROC) showed that the models generated from the texture analysis were able to predict healthy dogs with optimal levels of performance. Partial Least Square Discriminant Analysis (PLS-DA) obtained a sensitivity of 94% and a specificity of 96%, while Support Vector Machines (SVM) yielded a sensitivity of 99% and a specificity of 100%. The models, however, performed worse in classifying the type of disease in the diseased dog group: In diseased dogs with PTE sensitivities were 30% (PLS-DA) and 38% (SVM), and specificities were 80% (PLS-DA) and 89% (SVM). In diseased dogs without PTE the sensitivities of the models were 59% (PLS-DA) and 79% (SVM) and specificities were 79% (PLS-DA) and 82% (SVM). The results indicate that texture analysis of CTPA images using GLCM is an effective tool for distinguishing healthy from abnormal lung. Furthermore the texture of pulmonary parenchyma in dogs with PTE is altered, when compared to the texture of pulmonary parenchyma

  2. Texture analysis of ultrahigh field T2*-weighted MR images of the brain: application to Huntington's disease.

    Science.gov (United States)

    Doan, Nhat Trung; van den Bogaard, Simon J A; Dumas, Eve M; Webb, Andrew G; van Buchem, Mark A; Roos, Raymund A C; van der Grond, Jeroen; Reiber, Johan H C; Milles, Julien

    2014-03-01

    To develop a framework for quantitative detection of between-group textural differences in ultrahigh field T2*-weighted MR images of the brain. MR images were acquired using a three-dimensional (3D) T2*-weighted gradient echo sequence on a 7 Tesla MRI system. The phase images were high-pass filtered to remove phase wraps. Thirteen textural features were computed for both the magnitude and phase images of a region of interest based on 3D Gray-Level Co-occurrence Matrix, and subsequently evaluated to detect between-group differences using a Mann-Whitney U-test. We applied the framework to study textural differences in subcortical structures between premanifest Huntington's disease (HD), manifest HD patients, and controls. In premanifest HD, four phase-based features showed a difference in the caudate nucleus. In manifest HD, 7 magnitude-based features showed a difference in the pallidum, 6 phase-based features in the caudate nucleus, and 10 phase-based features in the putamen. After multiple comparison correction, significant differences were shown in the putamen in manifest HD by two phase-based features (both adjusted P values=0.04). This study provides the first evidence of textural heterogeneity of subcortical structures in HD. Texture analysis of ultrahigh field T2*-weighted MR images can be useful for noninvasive monitoring of neurodegenerative diseases. Copyright © 2013 Wiley Periodicals, Inc.

  3. Relation between consumers' perceptions of color and texture of dairy desserts and instrumental measurements using a generalized procrustes analysis.

    Science.gov (United States)

    González-Tomás, L; Costell, E

    2006-12-01

    Consumers' perceptions of the color and texture of 8 commercial vanilla dairy desserts were studied and related to color and rheological measurements. First, the 8 desserts were evaluated by a group of consumers by means of the Free Choice Profile. For both color and texture, a 2-dimensional solution was chosen, with dimension 1 highly related to yellow color intensity in the case of color and to thickness in the case of texture. Second, mechanical spectra, flow behavior, and instrumental color were determined. All the samples showed a time-dependent and shear-thinning flow and a mechanical spectrum typical of a weak gel. Differences were found in the flow index, in the apparent viscosity at 10 s(-1), and in the values of the storage modulus, the loss modulus, the loss angle tangent, and the complex viscosity at 1 Hz, as well as in the color parameters. Finally, sensory and instrumental relationships were investigated by a generalized Procrustes analysis. For both color and texture, a 3-dimensional solution explained a high percentage of the total variance (>80%). In these particular samples, the instrumental color parameters provided more accurate information on consumers' color perceptions than was provided by the rheological parameters of consumers' perceptions of texture.

  4. Cooking Methods for a Soft Diet Using Chicken Based on Food Texture Analysis.

    Science.gov (United States)

    Watanabe, Emi; Maeno, Masami; Kayashita, Jun; Miyamoto, Ken-Ichi; Kogirima, Miho

    2017-01-01

    Undernutrition caused by difficulties in masticating is of growing concern among the elderly. Soft diets are often served at nursing homes; however, the styles differ with nursing homes. Improperly modified food texture and consistency may lead to further loss of nutritive value. Therefore, we developed a method to produce a soft diet using chicken. The texture-modified chicken was prepared by boiling a mixture of minced chicken and additive foodstuff that softened the meat. The best food additive was determined through testing cooking process, size after modification and texture. The optimum proportions of each component in the mixture were determined measuring food texture using a creep meter. Teriyaki chicken was cooked using the texture-modified chicken, and provided to a nursing home. The amount of food intake by elderly residents was subsequently surveyed. This study involved 22 residents (1 man and 21 women; mean age 91.4±5.3 y). Consequently, yakifu, which was made from wheat gluten, was the most suitable additive foodstuff. The hardness of the texture-modified chicken, with proportions of minced chicken, yakifu, and water being 50%, 10%, and 40% respectively, was under 40,000 N/m 2 . The intake amount of the texture-modified chicken of subjects whose intake amount of conventional chicken using chicken thigh was not 100% was significantly higher. These findings suggest that properly modified food textures could contribute to improve the quality of meals by preventing undernutrition among the elderly with mastication difficulties.

  5. Analysis of through-thickness heterogeneities of microstructure and texture in nickel after accumulative roll bonding

    DEFF Research Database (Denmark)

    Zhang, Yubin; Mishin, Oleg; Godfrey, A.

    2014-01-01

    with the summed fraction of the rolling texture components. The observed microstructural and textural variations are discussed and compared with literature data, taking into account the influence of large-draught rolling and lubrication on the distribution of strain imposed during the ARB process....

  6. Texture analysis for survival prediction of pancreatic ductal adenocarcinoma patients with neoadjuvant chemotherapy

    Science.gov (United States)

    Chakraborty, Jayasree; Langdon-Embry, Liana; Escalon, Joanna G.; Allen, Peter J.; Lowery, Maeve A.; O'Reilly, Eileen M.; Do, Richard K. G.; Simpson, Amber L.

    2016-03-01

    Pancreatic ductal adenocarcinoma (PDAC) is the fourth leading cause of cancer-related death in the United States. The five-year survival rate for all stages is approximately 6%, and approximately 2% when presenting with distant disease.1 Only 10-20% of all patients present with resectable disease, but recurrence rates are high with only 5 to 15% remaining free of disease at 5 years. At this time, we are unable to distinguish between resectable PDAC patients with occult metastatic disease from those with potentially curable disease. Early classification of these tumor types may eventually lead to changes in initial management including the use of neoadjuvant chemotherapy or radiation, or in the choice of postoperative adjuvant treatments. Texture analysis is an emerging methodology in oncologic imaging for quantitatively assessing tumor heterogeneity that could potentially aid in the stratification of these patients. The present study derives several texture-based features from CT images of PDAC patients, acquired prior to neoadjuvant chemotherapy, and analyzes their performance, individually as well as in combination, as prognostic markers. A fuzzy minimum redundancy maximum relevance method with leave-one-image-out technique is included to select discriminating features from the set of extracted features. With a naive Bayes classifier, the proposed method predicts the 5-year overall survival of PDAC patients prior to neoadjuvant therapy and achieves the best results in terms of the area under the receiver operating characteristic curve of 0:858 and accuracy of 83:0% with four-fold cross-validation techniques.

  7. Assessment of Textural Differentiations in Forest Resources in Romania Using Fractal Analysis

    Directory of Open Access Journals (Sweden)

    Ion Andronache

    2017-02-01

    Full Text Available Deforestation and forest degradation have several negative effects on the environment including a loss of species habitats, disturbance of the water cycle and reduced ability to retain CO2, with consequences for global warming. We investigated the evolution of forest resources from development regions in Romania affected by both deforestation and reforestation using a non-Euclidean method based on fractal analysis. We calculated four fractal dimensions of forest areas: the fractal box-counting dimension of the forest areas, the fractal box-counting dimension of the dilated forest areas, the fractal dilation dimension and the box-counting dimension of the border of the dilated forest areas. Fractal analysis revealed morpho-structural and textural differentiations of forested, deforested and reforested areas in development regions with dominant mountain relief and high hills (more forested and compact organization in comparison to the development regions dominated by plains or low hills (less forested, more fragmented with small and isolated clusters. Our analysis used the fractal analysis that has the advantage of analyzing the entire image, rather than studying local information, thereby enabling quantification of the uniformity, fragmentation, heterogeneity and homogeneity of forests.

  8. Laws' masks descriptors applied to bone texture analysis: an innovative and discriminant tool in osteoporosis

    International Nuclear Information System (INIS)

    Rachidi, M.; Marchadier, A.; Gadois, C.; Lespessailles, E.; Chappard, C.; Benhamou, C.L.

    2008-01-01

    The objective of this study was to explore Laws' masks analysis to describe structural variations of trabecular bone due to osteoporosis on high-resolution digital radiographs and to check its dependence on the spatial resolution. Laws' masks are well established as one of the best methods for texture analysis in image processing and are used in various applications, but not in bone tissue characterisation. This method is based on masks that aim to filter the images. From each mask, five classical statistical parameters can be calculated. The study was performed on 182 healthy postmenopausal women with no fractures and 114 age-matched women with fractures [26 hip fractures (HFs), 29 vertebrae fractures (VFs), 29 wrist fractures (WFs) and 30 other fractures (OFs)]. For all subjects radiographs were obtained of the calcaneus with a new high-resolution X-ray device with direct digitisation (BMA, D3A, France). The lumbar spine, femoral neck, and total hip bone mineral density (BMD) were assessed by dual-energy X-ray absorptiometry. In terms of reproducibility, the best results were obtained with the TR E5E5 mask, especially for three parameters: ''mean'', ''standard deviation'' and ''entropy'' with, respectively, in vivo mid-term root mean square average coefficient of variation (RMSCV)%=1.79, 4.24 and 2.05. The ''mean'' and ''entropy'' parameters had a better reproducibility but ''standard deviation'' showed a better discriminant power. Thus, for univariate analysis, the difference between subjects with fractures and controls was significant (P -3 ) and significant for each fracture group independently (P -4 for HF, P=0.025 for VF and P -3 for OF). After multivariate analysis with adjustment for age and total hip BMD, the difference concerning the ''standard deviation'' parameter remained statistically significant between the control group and the HF and VF groups (P -5 , and P=0.04, respectively). No significant correlation between these Laws' masks parameters and

  9. Quantitative analysis of textures produced in a hot-extruded zirconium plate

    International Nuclear Information System (INIS)

    Couterne, J.

    1967-01-01

    The textures produced in zirconium by the extrusion at 730 deg C of a cylindrical billet in the form of a plate having a rectangular cross-section, have been studied by the Schulz method using an isotropic standard. These textures have been determined both parallel to the plane of the plate and parallel to the plane of the sides, All the results are analyzed in a final discussion which makes it possible to show, in particular near the edges of the plate, that certain components of the textures observed in the two series of recordings are in fact aspects of the same texture seen from two different angles, It is shown furthermore that the zirconium thus shaped has cold-work textures and als recrystallisation textures formed after the preceding cold-working, If the observed textures are considered schematically, it can be see that two of these have already been described in the literature and are similar to those found in rolled products: these textures are such that the (0001) planes are inclined at 36 deg C and 60 deg C respectively with respect to a plan tangential to the curve (envelope of transverse flow rates) resulting from the extrusion geometry under consideration; the third texture is defined. by the fact that the (0001) plane is orthogonal to the exterior surfaces of the plate. The direction of extrusion associated with these planes and common to the three textures is of the type , Dilatometric tests have been carried out on samples taken both parallel and perpendicular to the extrusion direction, These tests show that the zirconium is dilatometrically anisotropic and that a plot of (α v )-a against temperature shows a change of gradient at 400 deg C, this latter effect may be due to the change in the electronic configuration of the metal occurring at this temperature. (author) [fr

  10. Remote sensing of selective logging in Amazonia Assessing limitations based on detailed field observations, Landsat ETM+, and textural analysis.

    Science.gov (United States)

    Gregory P. Asner; Michael Keller; Rodrigo Pereira; Johan C. Zweede

    2002-01-01

    We combined a detailed field study of forest canopy damage with calibrated Landsat 7 Enhanced Thematic Mapper Plus (ETM+) reflectance data and texture analysis to assess the sensitivity of basic broadband optical remote sensing to selective logging in Amazonia. Our field study encompassed measurements of ground damage and canopy gap fractions along a chronosequence of...

  11. Profile fitting and the two-stage method in neutron powder diffractometry for structure and texture analysis

    International Nuclear Information System (INIS)

    Jansen, E.; Schaefer, W.; Will, G.; Kernforschungsanlage Juelich G.m.b.H.

    1988-01-01

    An outline and an application of the two-stage method in neutron powder diffractometry are presented. Stage (1): Individual reflection data like position, half-width and integrated intensity are analysed by profile fitting. The profile analysis is based on an experimentally determined instrument function and can be applied without prior knowledge of a structural model. A mathematical procedure is described which results in a variance-covariance matrix containing standard deviations and correlations of the refined reflection parameters. Stage (2): The individual reflection data derived from the profile fitting procedure can be used for appropriate purposes either in structure determination or in texture and strain or stress analysis. The integrated intensities are used in the non-diagonal weighted least-squares routine POWLS for structure refinement. The weight matrix is given by the inverted variance-covariance matrix of stage (1). This procedure is the basis for reliable and real Bragg R values and for a realistic estimation of standard deviations of structural parameters. In the case of texture analysis the integrated intensities are compiled into pole figures representing the intensity distribution for all sample orientations of individual hkl. Various examples for the wide application of the two-stage method in structure and texture analysis are given: Structure refinement of a standard quartz specimen, magnetic ordering in the system Tb x Y 1-x Ag, preferred orientation effects in deformed marble and texture investigations of a triclinic plagioclase. (orig.)

  12. Examples of neutron diffraction texture analysis on one and the same chalcopyrite sample before and after experimental deformation

    International Nuclear Information System (INIS)

    Jansen, E.M.; Brokmeier, H.G.; Siemes, H.

    1994-01-01

    Natural chalcopyrite specimens from Mt. Isa, Australia were investigated by neutron diffraction texture analysis. The preferred orientation of the specimens consists of 3 main orientation components. After axial shortening at a temperature of 25 C the initial orientation components became weaker, a new component was detected. (orig.)

  13. MRI texture analysis in differentiating luminal A and luminal B breast cancer molecular subtypes - a feasibility study.

    Science.gov (United States)

    Holli-Helenius, Kirsi; Salminen, Annukka; Rinta-Kiikka, Irina; Koskivuo, Ilkka; Brück, Nina; Boström, Pia; Parkkola, Riitta

    2017-12-29

    The aim of this study was to use texture analysis (TA) of breast magnetic resonance (MR) images to assist in differentiating estrogen receptor (ER) positive breast cancer molecular subtypes. Twenty-seven patients with histopathologically proven invasive ductal breast cancer were selected in preliminary study. Tumors were classified into molecular subtypes: luminal A (ER-positive and/or progesterone receptor (PR)-positive, human epidermal growth factor receptor type 2 (HER2) -negative, proliferation marker Ki-67 MaZda. Texture parameters and tumour volumes were correlated with tumour prognostic factors. Textural differences were observed mainly in precontrast images. The two most discriminative texture parameters to differentiate luminal A and luminal B subtypes were sum entropy and sum variance (p = 0.003). The AUCs were 0.828 for sum entropy (p = 0.004), and 0.833 for sum variance (p = 0.003), and 0.878 for the model combining texture features sum entropy, sum variance (p = 0.001). In the LOOCV, the AUC for model combining features sum entropy and sum variance was 0.876. Sum entropy and sum variance showed positive correlation with higher Ki-67 index. Luminal B types were larger in volume and moderate correlation between larger tumour volume and higher Ki-67 index was also observed (r = 0.499, p = 0.008). Texture features which measure randomness, heterogeneity or smoothness and homogeneity may either directly or indirectly reflect underlying growth patterns of breast tumours. TA and volumetric analysis may provide a way to evaluate the biologic aggressiveness of breast tumours and provide aid in decisions regarding therapeutic efficacy.

  14. Evaluation of Liver Fibrosis Using Texture Analysis on Combined-Contrast-Enhanced Magnetic Resonance Images at 3.0T

    Directory of Open Access Journals (Sweden)

    Takeshi Yokoo

    2015-01-01

    Full Text Available Purpose. To noninvasively assess liver fibrosis using combined-contrast-enhanced (CCE magnetic resonance imaging (MRI and texture analysis. Materials and Methods. In this IRB-approved, HIPAA-compliant prospective study, 46 adults with newly diagnosed HCV infection and recent liver biopsy underwent CCE liver MRI following intravenous administration of superparamagnetic iron oxides (ferumoxides and gadolinium DTPA (gadopentetate dimeglumine. The image texture of the liver was quantified in regions-of-interest by calculating 165 texture features. Liver biopsy specimens were stained with Masson trichrome and assessed qualitatively (METAVIR fibrosis score and quantitatively (% collagen stained area. Using L1 regularization path algorithm, two texture-based multivariate linear models were constructed, one for quantitative and the other for quantitative histology prediction. The prediction performance of each model was assessed using receiver operating characteristics (ROC and correlation analyses. Results. The texture-based predicted fibrosis score significantly correlated with qualitative (r=0.698, P<0.001 and quantitative (r=0.757, P<0.001 histology. The prediction model for qualitative histology had 0.814–0.976 areas under the curve (AUC, 0.659–1.000 sensitivity, 0.778–0.930 specificity, and 0.674–0.935 accuracy, depending on the binary classification threshold. The prediction model for quantitative histology had 0.742–0.950 AUC, 0.688–1.000 sensitivity, 0.679–0.857 specificity, and 0.696–0.848 accuracy, depending on the binary classification threshold. Conclusion. CCE MRI and texture analysis may permit noninvasive assessment of liver fibrosis.

  15. Quantitative analysis of textures produced in a hot-extruded zirconium plate; Analyse quantitative des textures developpees dans une plaque de zirconium filee a chaud

    Energy Technology Data Exchange (ETDEWEB)

    Couterne, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Institut national des sciences et techniques nucleaires, laboratoire de metallurgie

    1967-01-01

    The textures produced in zirconium by the extrusion at 730 deg C of a cylindrical billet in the form of a plate having a rectangular cross-section, have been studied by the Schulz method using an isotropic standard. These textures have been determined both parallel to the plane of the plate and parallel to the plane of the sides, All the results are analyzed in a final discussion which makes it possible to show, in particular near the edges of the plate, that certain components of the textures observed in the two series of recordings are in fact aspects of the same texture seen from two different angles, It is shown furthermore that the zirconium thus shaped has cold-work textures and als recrystallisation textures formed after the preceding cold-working, If the observed textures are considered schematically, it can be see that two of these have already been described in the literature and are similar to those found in rolled products: these textures are such that the (0001) planes are inclined at 36 deg C and 60 deg C respectively with respect to a plan tangential to the curve (envelope of transverse flow rates) resulting from the extrusion geometry under consideration; the third texture is defined. by the fact that the (0001) plane is orthogonal to the exterior surfaces of the plate. The direction of extrusion associated with these planes and common to the three textures is of the type <1010>, Dilatometric tests have been carried out on samples taken both parallel and perpendicular to the extrusion direction, These tests show that the zirconium is dilatometrically anisotropic and that a plot of ({alpha}{sub v})-a against temperature shows a change of gradient at 400 deg C, this latter effect may be due to the change in the electronic configuration of the metal occurring at this temperature. (author) [French] Les textures conferees au zirconium par filage a chaud a 730 deg C d'une billette cylindrique sous forme d'une plaque de section rectangulaire, ont ete

  16. Quantitative analysis of textures produced in a hot-extruded zirconium plate; Analyse quantitative des textures developpees dans une plaque de zirconium filee a chaud

    Energy Technology Data Exchange (ETDEWEB)

    Couterne, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Institut national des sciences et techniques nucleaires, laboratoire de metallurgie

    1967-01-01

    The textures produced in zirconium by the extrusion at 730 deg C of a cylindrical billet in the form of a plate having a rectangular cross-section, have been studied by the Schulz method using an isotropic standard. These textures have been determined both parallel to the plane of the plate and parallel to the plane of the sides, All the results are analyzed in a final discussion which makes it possible to show, in particular near the edges of the plate, that certain components of the textures observed in the two series of recordings are in fact aspects of the same texture seen from two different angles, It is shown furthermore that the zirconium thus shaped has cold-work textures and als recrystallisation textures formed after the preceding cold-working, If the observed textures are considered schematically, it can be see that two of these have already been described in the literature and are similar to those found in rolled products: these textures are such that the (0001) planes are inclined at 36 deg C and 60 deg C respectively with respect to a plan tangential to the curve (envelope of transverse flow rates) resulting from the extrusion geometry under consideration; the third texture is defined. by the fact that the (0001) plane is orthogonal to the exterior surfaces of the plate. The direction of extrusion associated with these planes and common to the three textures is of the type <1010>, Dilatometric tests have been carried out on samples taken both parallel and perpendicular to the extrusion direction, These tests show that the zirconium is dilatometrically anisotropic and that a plot of ({alpha}{sub v})-a against temperature shows a change of gradient at 400 deg C, this latter effect may be due to the change in the electronic configuration of the metal occurring at this temperature. (author) [French] Les textures conferees au zirconium par filage a chaud a 730 deg C d'une billette cylindrique sous forme d'une plaque de section rectangulaire, ont

  17. Spectral multi-energy CT texture analysis with machine learning for tissue classification: an investigation using classification of benign parotid tumours as a testing paradigm.

    Science.gov (United States)

    Al Ajmi, Eiman; Forghani, Behzad; Reinhold, Caroline; Bayat, Maryam; Forghani, Reza

    2018-06-01

    There is a rich amount of quantitative information in spectral datasets generated from dual-energy CT (DECT). In this study, we compare the performance of texture analysis performed on multi-energy datasets to that of virtual monochromatic images (VMIs) at 65 keV only, using classification of the two most common benign parotid neoplasms as a testing paradigm. Forty-two patients with pathologically proven Warthin tumour (n = 25) or pleomorphic adenoma (n = 17) were evaluated. Texture analysis was performed on VMIs ranging from 40 to 140 keV in 5-keV increments (multi-energy analysis) or 65-keV VMIs only, which is typically considered equivalent to single-energy CT. Random forest (RF) models were constructed for outcome prediction using separate randomly selected training and testing sets or the entire patient set. Using multi-energy texture analysis, tumour classification in the independent testing set had accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 92%, 86%, 100%, 100%, and 83%, compared to 75%, 57%, 100%, 100%, and 63%, respectively, for single-energy analysis. Multi-energy texture analysis demonstrates superior performance compared to single-energy texture analysis of VMIs at 65 keV for classification of benign parotid tumours. • We present and validate a paradigm for texture analysis of DECT scans. • Multi-energy dataset texture analysis is superior to single-energy dataset texture analysis. • DECT texture analysis has high accura\\cy for diagnosis of benign parotid tumours. • DECT texture analysis with machine learning can enhance non-invasive diagnostic tumour evaluation.

  18. Detection of neovascularization based on fractal and texture analysis with interaction effects in diabetic retinopathy.

    Science.gov (United States)

    Lee, Jack; Zee, Benny Chung Ying; Li, Qing

    2013-01-01

    Diabetic retinopathy is a major cause of blindness. Proliferative diabetic retinopathy is a result of severe vascular complication and is visible as neovascularization of the retina. Automatic detection of such new vessels would be useful for the severity grading of diabetic retinopathy, and it is an important part of screening process to identify those who may require immediate treatment for their diabetic retinopathy. We proposed a novel new vessels detection method including statistical texture analysis (STA), high order spectrum analysis (HOS), fractal analysis (FA), and most importantly we have shown that by incorporating their associated interactions the accuracy of new vessels detection can be greatly improved. To assess its performance, the sensitivity, specificity and accuracy (AUC) are obtained. They are 96.3%, 99.1% and 98.5% (99.3%), respectively. It is found that the proposed method can improve the accuracy of new vessels detection significantly over previous methods. The algorithm can be automated and is valuable to detect relatively severe cases of diabetic retinopathy among diabetes patients.

  19. Detection of neovascularization based on fractal and texture analysis with interaction effects in diabetic retinopathy.

    Directory of Open Access Journals (Sweden)

    Jack Lee

    Full Text Available Diabetic retinopathy is a major cause of blindness. Proliferative diabetic retinopathy is a result of severe vascular complication and is visible as neovascularization of the retina. Automatic detection of such new vessels would be useful for the severity grading of diabetic retinopathy, and it is an important part of screening process to identify those who may require immediate treatment for their diabetic retinopathy. We proposed a novel new vessels detection method including statistical texture analysis (STA, high order spectrum analysis (HOS, fractal analysis (FA, and most importantly we have shown that by incorporating their associated interactions the accuracy of new vessels detection can be greatly improved. To assess its performance, the sensitivity, specificity and accuracy (AUC are obtained. They are 96.3%, 99.1% and 98.5% (99.3%, respectively. It is found that the proposed method can improve the accuracy of new vessels detection significantly over previous methods. The algorithm can be automated and is valuable to detect relatively severe cases of diabetic retinopathy among diabetes patients.

  20. A procedure for the evaluation of 2D radiographic texture analysis to assess 3D bone micro-architecture

    International Nuclear Information System (INIS)

    Apostol, L.; Peyrin, F.; Yot, S.; Basset, O.; Odet, Ch.; Apostal, L.; Peyrin, F.; Boller, E.; Tabary, J.; Dinten, J.M.; Boudousq, V.; Kotzki, P.O.

    2004-01-01

    Although the diagnosis of osteoporosis is mainly based on Dual X-ray Absorptiometry, it has been shown that trabecular bone micro-architecture is also an important factor in regards of fracture risk, which can be efficiently assessed in vitro using three-dimensional x-ray microtomography (μCT). In vivo, techniques based on high-resolution x-ray radiography associated to texture analysis have been proposed to investigate bone micro-architecture, but their relevance for giving pertinent 3D information is unclear. The purpose of this work was to develop a method for evaluating the relationships between 3D micro-architecture and 2D texture parameters, and optimizing the conditions for radiographic imaging. Bone sample images taken from cortical to cortical were acquired using 3D-synchrotron x-ray μCT at the ESRF. The 3D digital images were further used for two purposes: 1) quantification of three-dimensional bone micro-architecture, 2) simulation of realistic x-ray radiographs under different acquisition conditions. Texture analysis was then applied to these 2D radiographs using a large variety of methods (co-occurrence, spectrum, fractal...). First results of the statistical analysis between 2D and 3D parameters allowed identifying the most relevant 2D texture parameters. (authors)

  1. The use of texture analysis in the vertebral morphometric study of a lordotic chub (Squalius cephalus L.

    Directory of Open Access Journals (Sweden)

    Maurizio Manera

    2014-08-01

    Full Text Available Objective: To characterise vertebral aspects of a lordotic chub (Squalius cephalus L. using texture analysis by radiograph and to verify possible alterations in the vertebral microarchitecture of the lordotic tract. Methods: Four vertebrae belonging to the lordotic tract were analyzed for their texture features by means of a software package (MaZda vers. 4.6 and were compared, for the same features, to other four vertebrae cranial (anterior to the lordotic vertebrae. Results: Two representative features were selected out of 259 extracted texture features by means of the convex hull selection method. In particular, (5, 5 sum of squares (according to cooccurrence matrix method and 45° short run emphasis (according to run-length matrix method were used to classify, without classification errors, two selected spinal tracts (the lordotic one and the immediately cranial one, both corresponding to the anal fin pterigiophores vertebral portion according to the following methods: linear discriminant analysis and hierarchical clustering. Conclusions: This is the first known application of texture analysis in medical imaging applied to fish species and represents a start point for further studies in aquariology and in aquaculture, where spinal deformities occur relative frequently and are cause of economic losses.

  2. Texture Analysis of Hydrophobic Polycarbonate and Polydimethylsiloxane Surfaces via Persistent Homology

    Directory of Open Access Journals (Sweden)

    Ali Nabi Duman

    2017-09-01

    Full Text Available Due to recent climate change-triggered, regular dust storms in the Middle East, dust mitigation has become the critical issue for solar energy harvesting devices. One of the methods to minimize and prevent dust adhesion and create self-cleaning abilities is to generate hydrophobic characteristics on surfaces. The purpose of this study is to explore the topological features of hydrophobic surfaces. We use non-standard techniques from topological data analysis to extract morphological features from the AFM images. Our method recovers most of the previous qualitative observations in a robust and quantitative way. Persistence diagrams, which is a summary of topological structures, witness quantitatively that the crystallized polycarbonate (PC surface possesses spherulites, voids, and fibrils, and the texture height and spherulite concentration increases with the increased immersion period. The approach also shows that the polydimethylsiloxane (PDMS exactly copied the structures at the PC surface but 80 to 90 percent of the nanofibrils were not copied at PDMS surface. We next extract a feature vector from each persistence diagram to show which experiments hold features with similar variance using principal component analysis (PCA. The K-means clustering algorithm is applied to the matrix of feature vectors to support the PCA result, grouping experiments with similar features.

  3. Unsupervised consensus cluster analysis of [18F]-fluoroethyl-L-tyrosine positron emission tomography identified textural features for the diagnosis of pseudoprogression in high-grade glioma.

    Science.gov (United States)

    Kebir, Sied; Khurshid, Zain; Gaertner, Florian C; Essler, Markus; Hattingen, Elke; Fimmers, Rolf; Scheffler, Björn; Herrlinger, Ulrich; Bundschuh, Ralph A; Glas, Martin

    2017-01-31

    Timely detection of pseudoprogression (PSP) is crucial for the management of patients with high-grade glioma (HGG) but remains difficult. Textural features of O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography (FET-PET) mirror tumor uptake heterogeneity; some of them may be associated with tumor progression. Fourteen patients with HGG and suspected of PSP underwent FET-PET imaging. A set of 19 conventional and textural FET-PET features were evaluated and subjected to unsupervised consensus clustering. The final diagnosis of true progression vs. PSP was based on follow-up MRI using RANO criteria. Three robust clusters have been identified based on 10 predominantly textural FET-PET features. None of the patients with PSP fell into cluster 2, which was associated with high values for textural FET-PET markers of uptake heterogeneity. Three out of 4 patients with PSP were assigned to cluster 3 that was largely associated with low values of textural FET-PET features. By comparison, tumor-to-normal brain ratio (TNRmax) at the optimal cutoff 2.1 was less predictive of PSP (negative predictive value 57% for detecting true progression, p=0.07 vs. 75% with cluster 3, p=0.04). Clustering based on textural O-(2-[18F]fluoroethyl)-L-tyrosine PET features may provide valuable information in assessing the elusive phenomenon of pseudoprogression.

  4. Multi-Parametric MRI and Texture Analysis to Visualize Spatial Histologic Heterogeneity and Tumor Extent in Glioblastoma.

    Directory of Open Access Journals (Sweden)

    Leland S Hu

    Full Text Available Genetic profiling represents the future of neuro-oncology but suffers from inadequate biopsies in heterogeneous tumors like Glioblastoma (GBM. Contrast-enhanced MRI (CE-MRI targets enhancing core (ENH but yields adequate tumor in only ~60% of cases. Further, CE-MRI poorly localizes infiltrative tumor within surrounding non-enhancing parenchyma, or brain-around-tumor (BAT, despite the importance of characterizing this tumor segment, which universally recurs. In this study, we use multiple texture analysis and machine learning (ML algorithms to analyze multi-parametric MRI, and produce new images indicating tumor-rich targets in GBM.We recruited primary GBM patients undergoing image-guided biopsies and acquired pre-operative MRI: CE-MRI, Dynamic-Susceptibility-weighted-Contrast-enhanced-MRI, and Diffusion Tensor Imaging. Following image coregistration and region of interest placement at biopsy locations, we compared MRI metrics and regional texture with histologic diagnoses of high- vs low-tumor content (≥80% vs <80% tumor nuclei for corresponding samples. In a training set, we used three texture analysis algorithms and three ML methods to identify MRI-texture features that optimized model accuracy to distinguish tumor content. We confirmed model accuracy in a separate validation set.We collected 82 biopsies from 18 GBMs throughout ENH and BAT. The MRI-based model achieved 85% cross-validated accuracy to diagnose high- vs low-tumor in the training set (60 biopsies, 11 patients. The model achieved 81.8% accuracy in the validation set (22 biopsies, 7 patients.Multi-parametric MRI and texture analysis can help characterize and visualize GBM's spatial histologic heterogeneity to identify regional tumor-rich biopsy targets.

  5. X-ray diffraction from thin films : Residual stress and texture analysis

    Energy Technology Data Exchange (ETDEWEB)

    Leoni, M; Scardi, [Trento Univ. (Italy). Dept. of Materials Engineering

    1996-09-01

    In this short contribution the attention will be drawn to the use of XRD-based non-destructive techniques for the study of the stress state and the orientation (texture) of various technologically valuable films. The cases in which the texture is important will be presented and they are: applicative examples, spacing in a wide variety of application areas and regarding growth-induced and machining-induced orientation.

  6. Precision of quantitative computed tomography texture analysis using image filtering: A phantom study for scanner variability.

    Science.gov (United States)

    Yasaka, Koichiro; Akai, Hiroyuki; Mackin, Dennis; Court, Laurence; Moros, Eduardo; Ohtomo, Kuni; Kiryu, Shigeru

    2017-05-01

    Quantitative computed tomography (CT) texture analyses for images with and without filtration are gaining attention to capture the heterogeneity of tumors. The aim of this study was to investigate how quantitative texture parameters using image filtering vary among different computed tomography (CT) scanners using a phantom developed for radiomics studies.A phantom, consisting of 10 different cartridges with various textures, was scanned under 6 different scanning protocols using four CT scanners from four different vendors. CT texture analyses were performed for both unfiltered images and filtered images (using a Laplacian of Gaussian spatial band-pass filter) featuring fine, medium, and coarse textures. Forty-five regions of interest were placed for each cartridge (x) in a specific scan image set (y), and the average of the texture values (T(x,y)) was calculated. The interquartile range (IQR) of T(x,y) among the 6 scans was calculated for a specific cartridge (IQR(x)), while the IQR of T(x,y) among the 10 cartridges was calculated for a specific scan (IQR(y)), and the median IQR(y) was then calculated for the 6 scans (as the control IQR, IQRc). The median of their quotient (IQR(x)/IQRc) among the 10 cartridges was defined as the variability index (VI).The VI was relatively small for the mean in unfiltered images (0.011) and for standard deviation (0.020-0.044) and entropy (0.040-0.044) in filtered images. Skewness and kurtosis in filtered images featuring medium and coarse textures were relatively variable across different CT scanners, with VIs of 0.638-0.692 and 0.430-0.437, respectively.Various quantitative CT texture parameters are robust and variable among different scanners, and the behavior of these parameters should be taken into consideration.

  7. Parameter set for computer-assisted texture analysis of fetal brain.

    Science.gov (United States)

    Gentillon, Hugues; Stefańczyk, Ludomir; Strzelecki, Michał; Respondek-Liberska, Maria

    2016-11-25

    Magnetic resonance data were collected from a diverse population of gravid women to objectively compare the quality of 1.5-tesla (1.5 T) versus 3-T magnetic resonance imaging of the developing human brain. MaZda and B11 computational-visual cognition tools were used to process 2D images. We proposed a wavelet-based parameter and two novel histogram-based parameters for Fisher texture analysis in three-dimensional space. Wavenhl, focus index, and dispersion index revealed better quality for 3 T. Though both 1.5 and 3 T images were 16-bit DICOM encoded, nearly 16 and 12 usable bits were measured in 3 and 1.5 T images, respectively. The four-bit padding observed in 1.5 T K-space encoding mimics noise by adding illusionistic details, which are not really part of the image. In contrast, zero-bit padding in 3 T provides space for storing more details and increases the likelihood of noise but as well as edges, which in turn are very crucial for differentiation of closely related anatomical structures. Both encoding modes are possible with both units, but higher 3 T resolution is the main difference. It contributes to higher perceived and available dynamic range. Apart from surprisingly larger Fisher coefficient, no significant difference was observed when testing was conducted with down-converted 8-bit BMP images.

  8. Clinical applications of textural analysis in non-small cell lung cancer.

    Science.gov (United States)

    Phillips, Iain; Ajaz, Mazhar; Ezhil, Veni; Prakash, Vineet; Alobaidli, Sheaka; McQuaid, Sarah J; South, Christopher; Scuffham, James; Nisbet, Andrew; Evans, Philip

    2018-01-01

    Lung cancer is the leading cause of cancer mortality worldwide. Treatment pathways include regular cross-sectional imaging, generating large data sets which present intriguing possibilities for exploitation beyond standard visual interpretation. This additional data mining has been termed "radiomics" and includes semantic and agnostic approaches. Textural analysis (TA) is an example of the latter, and uses a range of mathematically derived features to describe an image or region of an image. Often TA is used to describe a suspected or known tumour. TA is an attractive tool as large existing image sets can be submitted to diverse techniques for data processing, presentation, interpretation and hypothesis testing with annotated clinical outcomes. There is a growing anthology of published data using different TA techniques to differentiate between benign and malignant lung nodules, differentiate tissue subtypes of lung cancer, prognosticate and predict outcome and treatment response, as well as predict treatment side effects and potentially aid radiotherapy planning. The aim of this systematic review is to summarize the current published data and understand the potential future role of TA in managing lung cancer.

  9. Historical Texture Analysis of Küçük Kumla Village and Preservation Proposals

    Directory of Open Access Journals (Sweden)

    Tülay ESİN

    2013-08-01

    Full Text Available Küçük Kumla Village, which is situated in the Marmara region, Bursa City and Gemlik District embraces traces of different cultures with respect to its fertile soil character, mild climate and location. In this study, the features of the traditional neighbourhood in Küçük Kumla Village are sought to research. Through the coverage of analysis made, it is found out that the traditional texture of the village has been deteriorating gradually. Due to the fact that the varying life styles and new comfort necessities are not fulfilled by the traditional civil architectural samples, the society leads to new building production rather than traditional building usage. Another issue that results with the abandonment is the immigration to the towns and city centres from the region regarding various reasons. Not providing necessary care on the abandoned buildings tends to accelerate the deterioration process. The buildings constructs on the previous historical buildings contradicting with the original thus preventing the sense of traditional texture of the village. Through contemporary and applicable proposals provided in this study, it is predicted that historical textural deterioration of the region can be prevented and the texture of the village can be rehabilitated and preserved

  10. Application of Image Texture Analysis for Evaluation of X-Ray Images of Fungal-Infected Maize Kernels

    DEFF Research Database (Denmark)

    Orina, Irene; Manley, Marena; Kucheryavskiy, Sergey V.

    2018-01-01

    The feasibility of image texture analysis to evaluate X-ray images of fungal-infected maize kernels was investigated. X-ray images of maize kernels infected with Fusarium verticillioides and control kernels were acquired using high-resolution X-ray micro-computed tomography. After image acquisition...... developed using partial least squares discriminant analysis (PLS-DA), and accuracies of 67 and 73% were achieved using first-order statistical features and GLCM extracted features, respectively. This work provides information on the possible application of image texture as method for analysing X-ray images......., homogeneity and contrast) were extracted from the side, front and top views of each kernel and used as inputs for principal component analysis (PCA). The first-order statistical image features gave a better separation of the control from infected kernels on day 8 post-inoculation. Classification models were...

  11. On the use of a composite moderator at the IBR-2 reactor: Advantages for the neutron-diffraction texture analysis of rocks

    Czech Academy of Sciences Publication Activity Database

    Bulavin, M. V.; Vasin, R.N.; Kulikov, S.A.; Lokajíček, Tomáš; Levin, D.M.

    2016-01-01

    Roč. 10, č. 4 (2016), s. 677-686 ISSN 1027-4510 Institutional support: RVO:67985831 Keywords : cold moderator * neutron-diffraction texture analysis * phase analysis * Rietveld method Subject RIV: DB - Geology ; Mineralogy

  12. Progression Analysis and Stage Discovery in Continuous Physiological Processes Using Image Computing

    Directory of Open Access Journals (Sweden)

    Ferrucci Luigi

    2010-01-01

    Full Text Available We propose an image computing-based method for quantitative analysis of continuous physiological processes that can be sensed by medical imaging and demonstrate its application to the analysis of morphological alterations of the bone structure, which correlate with the progression of osteoarthritis (OA. The purpose of the analysis is to quantitatively estimate OA progression in a fashion that can assist in understanding the pathophysiology of the disease. Ultimately, the texture analysis will be able to provide an alternative OA scoring method, which can potentially reflect the progression of the disease in a more direct fashion compared to the existing clinically utilized classification schemes based on radiology. This method can be useful not just for studying the nature of OA, but also for developing and testing the effect of drugs and treatments. While in this paper we demonstrate the application of the method to osteoarthritis, its generality makes it suitable for the analysis of other progressive clinical conditions that can be diagnosed and prognosed by using medical imaging.

  13. Tumor spatial heterogeneity in myxoid-containing soft tissue using texture analysis of diffusion-weighted MRI.

    Directory of Open Access Journals (Sweden)

    Hyun Su Kim

    Full Text Available The objective of this study was to examine the tumor spatial heterogeneity in myxoid-containing soft-tissue tumors (STTs using texture analysis of diffusion-weighted imaging (DWI. A total of 40 patients with myxoid-containing STTs (23 benign and 17 malignant were included in this study. The region of interest (ROI was manually drawn on the apparent diffusion coefficient (ADC map. For texture analysis, the global (mean, standard deviation, skewness, and kurtosis, regional (intensity variability and size-zone variability, and local features (energy, entropy, correlation, contrast, homogeneity, variance, and maximum probability were extracted from the ADC map. Student's t-test was used to test the difference between group means. Analysis of covariance (ANCOVA was performed with adjustments for age, sex, and tumor volume. The receiver operating characteristic (ROC analysis was performed to compare diagnostic performances. Malignant myxoid-containing STTs had significantly higher kurtosis (P = 0.040, energy (P = 0.034, correlation (P<0.001, and homogeneity (P = 0.003, but significantly lower contrast (P<0.001 and variance (P = 0.001 compared with benign myxoid-containing STTs. Contrast showed the highest area under the curve (AUC = 0.923, P<0.001, sensitivity (94.12%, and specificity (86.96%. Our results reveal the potential utility of texture analysis of ADC maps for differentiating benign and malignant myxoid-containing STTs.

  14. The precision of textural analysis in {sup 18}F-FDG-PET scans of oesophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Doumou, Georgia; Siddique, Musib [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Tsoumpas, Charalampos [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); University of Leeds, The Division of Medical Physics, Leeds (United Kingdom); Goh, Vicky [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Guy' s and St Thomas' Hospitals NHS Foundation Trust, Radiology Department, London (United Kingdom); Cook, Gary J. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Guy' s and St Thomas' Hospitals NHS Foundation Trust, The PET Centre, London (United Kingdom); University of Leeds, The Division of Medical Physics, Leeds (United Kingdom); St Thomas' Hospital, Clinical PET Centre, Division of Imaging Sciences and Biomedical Engineering, Kings College London, London (United Kingdom)

    2015-09-15

    Measuring tumour heterogeneity by textural analysis in {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) provides predictive and prognostic information but technical aspects of image processing can influence parameter measurements. We therefore tested effects of image smoothing, segmentation and quantisation on the precision of heterogeneity measurements. Sixty-four {sup 18}F-FDG PET/CT images of oesophageal cancer were processed using different Gaussian smoothing levels (2.0, 2.5, 3.0, 3.5, 4.0 mm), maximum standardised uptake value (SUV{sub max}) segmentation thresholds (45 %, 50 %, 55 %, 60 %) and quantisation (8, 16, 32, 64, 128 bin widths). Heterogeneity parameters included grey-level co-occurrence matrix (GLCM), grey-level run length matrix (GLRL), neighbourhood grey-tone difference matrix (NGTDM), grey-level size zone matrix (GLSZM) and fractal analysis methods. The concordance correlation coefficient (CCC) for the three processing variables was calculated for each heterogeneity parameter. Most parameters showed poor agreement between different bin widths (CCC median 0.08, range 0.004-0.99). Segmentation and smoothing showed smaller effects on precision (segmentation: CCC median 0.82, range 0.33-0.97; smoothing: CCC median 0.99, range 0.58-0.99). Smoothing and segmentation have only a small effect on the precision of heterogeneity measurements in {sup 18}F-FDG PET data. However, quantisation often has larger effects, highlighting a need for further evaluation and standardisation of parameters for multicentre studies. (orig.)

  15. An explorative childhood pneumonia analysis based on ultrasonic imaging texture features

    Science.gov (United States)

    Zenteno, Omar; Diaz, Kristians; Lavarello, Roberto; Zimic, Mirko; Correa, Malena; Mayta, Holger; Anticona, Cynthia; Pajuelo, Monica; Oberhelman, Richard; Checkley, William; Gilman, Robert H.; Figueroa, Dante; Castañeda, Benjamín.

    2015-12-01

    According to World Health Organization, pneumonia is the respiratory disease with the highest pediatric mortality rate accounting for 15% of all deaths of children under 5 years old worldwide. The diagnosis of pneumonia is commonly made by clinical criteria with support from ancillary studies and also laboratory findings. Chest imaging is commonly done with chest X-rays and occasionally with a chest CT scan. Lung ultrasound is a promising alternative for chest imaging; however, interpretation is subjective and requires adequate training. In the present work, a two-class classification algorithm based on four Gray-level co-occurrence matrix texture features (i.e., Contrast, Correlation, Energy and Homogeneity) extracted from lung ultrasound images from children aged between six months and five years is presented. Ultrasound data was collected using a L14-5/38 linear transducer. The data consisted of 22 positive- and 68 negative-diagnosed B-mode cine-loops selected by a medical expert and captured in the facilities of the Instituto Nacional de Salud del Niño (Lima, Peru), for a total number of 90 videos obtained from twelve children diagnosed with pneumonia. The classification capacity of each feature was explored independently and the optimal threshold was selected by a receiver operator characteristic (ROC) curve analysis. In addition, a principal component analysis was performed to evaluate the combined performance of all the features. Contrast and correlation resulted the two more significant features. The classification performance of these two features by principal components was evaluated. The results revealed 82% sensitivity, 76% specificity, 78% accuracy and 0.85 area under the ROC.

  16. Tensile properties of cooked meat sausages and their correlation with texture profile analysis (TPA) parameters and physico-chemical characteristics.

    Science.gov (United States)

    Herrero, A M; de la Hoz, L; Ordóñez, J A; Herranz, B; Romero de Ávila, M D; Cambero, M I

    2008-11-01

    The possibilities of using breaking strength (BS) and energy to fracture (EF) for monitoring textural properties of some cooked meat sausages (chopped, mortadella and galantines) were studied. Texture profile analysis (TPA), folding test and physico-chemical measurements were also performed. Principal component analysis enabled these meat products to be grouped into three textural profiles which showed significant (p<0.05) differences mainly for BS, hardness, adhesiveness and cohesiveness. Multivariate analysis indicated that BS, EF and TPA parameters were correlated (p<0.05) for every individual meat product (chopped, mortadella and galantines) and all products together. On the basis of these results, TPA parameters could be used for constructing regression models to predict BS. The resulting regression model for all cooked meat products was BS=-0.160+6.600∗cohesiveness-1.255∗adhesiveness+0.048∗hardness-506.31∗springiness (R(2)=0.745, p<0.00005). Simple linear regression analysis showed significant coefficients of determination between BS (R(2)=0.586, p<0.0001) versus folding test grade (FG) and EF versus FG (R(2)=0.564, p<0.0001).

  17. Introduction of High Throughput Magnetic Resonance T2-Weighted Image Texture Analysis for WHO Grade 2 and 3 Gliomas.

    Science.gov (United States)

    Kinoshita, Manabu; Sakai, Mio; Arita, Hideyuki; Shofuda, Tomoko; Chiba, Yasuyoshi; Kagawa, Naoki; Watanabe, Yoshiyuki; Hashimoto, Naoya; Fujimoto, Yasunori; Yoshimine, Toshiki; Nakanishi, Katsuyuki; Kanemura, Yonehiro

    2016-01-01

    Reports have suggested that tumor textures presented on T2-weighted images correlate with the genetic status of glioma. Therefore, development of an image analyzing framework that is capable of objective and high throughput image texture analysis for large scale image data collection is needed. The current study aimed to address the development of such a framework by introducing two novel parameters for image textures on T2-weighted images, i.e., Shannon entropy and Prewitt filtering. Twenty-two WHO grade 2 and 28 grade 3 glioma patients were collected whose pre-surgical MRI and IDH1 mutation status were available. Heterogeneous lesions showed statistically higher Shannon entropy than homogenous lesions (p = 0.006) and ROC curve analysis proved that Shannon entropy on T2WI was a reliable indicator for discrimination of homogenous and heterogeneous lesions (p = 0.015, AUC = 0.73). Lesions with well-defined borders exhibited statistically higher Edge mean and Edge median values using Prewitt filtering than those with vague lesion borders (p = 0.0003 and p = 0.0005 respectively). ROC curve analysis also proved that both Edge mean and median values were promising indicators for discrimination of lesions with vague and well defined borders and both Edge mean and median values performed in a comparable manner (p = 0.0002, AUC = 0.81 and p image metrics that reflect lesion texture described on T2WI. These two metrics were validated by readings of a neuro-radiologist who was blinded to the results. This observation will facilitate further use of this technique in future large scale image analysis of glioma.

  18. Wavelet-packet-based texture analysis for differentiation between benign and malignant liver tumours in ultrasound images

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki; Casalino, David D; Keserci, Bilgin; Coskun, Abdulhakim; Ozturk, Omer; Savranlar, Ahmet

    2003-01-01

    The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesions were decomposed into subimages by wavelet packets. Multiscale texture features that quantify homogeneity of the echogenicity were calculated from these subimages and were combined by an artificial neural network (ANN). A subset of the multiscale features was selected that yielded the highest performance in the classification of lesions measured by the area under the receiver operating characteristic curve (A z ). In an analysis of 193 ROIs consisting of 50 hemangiomas, 87 hepatocellular carcinomas and 56 metastases, the multiscale features yielded a high A z value of 0.92 in distinguishing benign from malignant lesions, 0.93 in distinguishing hemangiomas from HCCs and 0.94 in distinguishing hemangiomas from metastases. Our new multiscale texture analysis method can effectively differentiate malignant from benign lesions, and thus has the potential to increase the accuracy of diagnosis of focal liver lesions in ultrasound images

  19. An automated classification system for the differentiation of obstructive lung diseases based on the textural analysis of HRCT images

    International Nuclear Information System (INIS)

    Park, Seong Hoon; Seo, Joon Beom; Kim, Nam Kug; Lee, Young Kyung; Kim, Song Soo; Chae, Eun Jin; Lee, June Goo

    2007-01-01

    To develop an automated classification system for the differentiation of obstructive lung diseases based on the textural analysis of HRCT images, and to evaluate the accuracy and usefulness of the system. For textural analysis, histogram features, gradient features, run length encoding, and a co-occurrence matrix were employed. A Bayesian classifier was used for automated classification. The images (image number n = 256) were selected from the HRCT images obtained from 17 healthy subjects (n = 67), 26 patients with bronchiolitis obliterans (n = 70), 28 patients with mild centrilobular emphysema (n = 65), and 21 patients with panlobular emphysema or severe centrilobular emphysema (n = 63). An five-fold cross-validation method was used to assess the performance of the system. Class-specific sensitivities were analyzed and the overall accuracy of the system was assessed with kappa statistics. The sensitivity of the system for each class was as follows: normal lung 84.9%, bronchiolitis obliterans 83.8%, mild centrilobular emphysema 77.0%, and panlobular emphysema or severe centrilobular emphysema 95.8%. The overall performance for differentiating each disease and the normal lung was satisfactory with a kappa value of 0.779. An automated classification system for the differentiation between obstructive lung diseases based on the textural analysis of HRCT images was developed. The proposed system discriminates well between the various obstructive lung diseases and the normal lung

  20. Texture of poled tetragonal PZT detected by synchrotron X-ray diffraction and micromechanics analysis

    International Nuclear Information System (INIS)

    Hall, D.A.; Steuwer, A.; Cherdhirunkorn, B.; Withers, P.J.; Mori, T.

    2005-01-01

    The texture and lattice elastic strain due to electrical poling of tetragonal PZT (lead zirconate titanate) ceramics have been measured using high energy synchrotron X-ray diffraction. It is shown that XRD peak intensity ratios associated with crystal planes of the form {002}, {112} and {202} exhibit a linear dependence on cos-bar 2 Ψ, where Ψ represents the orientation angle between the plane normal and the macroscopic poling axis. The observed dependence of texture and lattice strain on the grain orientation can be understood on the basis that the macroscopic strain due to poling is the average of the poling strains of all the individual grains

  1. Texture analysis of B-mode ultrasound images to stage hepatic lipidosis in the dairy cow: A methodological study.

    Science.gov (United States)

    Banzato, Tommaso; Fiore, Enrico; Morgante, Massimo; Manuali, Elisabetta; Zotti, Alessandro

    2016-10-01

    Hepatic lipidosis is the most diffused hepatic disease in the lactating cow. A new methodology to estimate the degree of fatty infiltration of the liver in lactating cows by means of texture analysis of B-mode ultrasound images is proposed. B-mode ultrasonography of the liver was performed in 48 Holstein Friesian cows using standardized ultrasound parameters. Liver biopsies to determine the triacylglycerol content of the liver (TAGqa) were obtained from each animal. A large number of texture parameters were calculated on the ultrasound images by means of a free software. Based on the TAGqa content of the liver, 29 samples were classified as mild (TAGqa100mg/g) and 13 as severe (TAG>100mg/g) in steatosis. Stepwise linear regression analysis was performed to predict the TAGqa content of the liver (TAGpred) from the texture parameters calculated on the ultrasound images. A five-variable model was used to predict the TAG content from the ultrasound images. The regression model explained 83.4% of the variance. An area under the curve (AUC) of 0.949 was calculated for 50mg/g of TAGqa; using an optimal cut-off value of 72mg/g TAGpred had a sensitivity of 86.2% and a specificity of 84.2%. An AUC of 0.978 for 100mg/g of TAGqa was calculated; using an optimal cut-off value of 89mg/g, TAGpred sensitivity was 92.3% and specificity was 88.6%. Texture analysis of B-mode ultrasound images may therefore be used to accurately predict the TAG content of the liver in lactating cows. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Diagnostic value of MRI-based 3D texture analysis for tissue characterisation and discrimination of low-grade chondrosarcoma from enchondroma. A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Lisson, Catharina S.; Lisson, Christoph G.; Flosdorf, Kerstin; Meier, Reinhard; Beer, Meinrad; Schmidt, Stefan A. [University Hospital of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Mayer-Steinacker, Regine [University Hospital of Ulm, Department of Internal Medicine III, Ulm (Germany); Schultheiss, Markus; Baer, Alexandra von [University Hospital of Ulm, Department of Trauma Surgery, Ulm (Germany); Barth, Thomas F.E. [University of Ulm, Institute of Pathology, Ulm (Germany); Beer, Ambros J. [University Hospital of Ulm, Department of Nuclear Medicine, Ulm (Germany); Baumhauer, Matthias [Mint Medical, Dossenheim (Germany)

    2018-02-15

    To explore the diagnostic value of MRI-based 3D texture analysis to identify texture features that can be used for discrimination of low-grade chondrosarcoma from enchondroma. Eleven patients with low-grade chondrosarcoma and 11 patients with enchondroma were retrospectively evaluated. Texture analysis was performed using mint Lesion: Kurtosis, entropy, skewness, mean of positive pixels (MPP) and uniformity of positive pixel distribution (UPP) were obtained in four MRI sequences and correlated with histopathology. The Mann-Whitney U-test and receiver operating characteristic (ROC) analysis were performed to identify most discriminative texture features. Sensitivity, specificity, accuracy and optimal cut-off values were calculated. Significant differences were found in four of 20 texture parameters with regard to the different MRI sequences (p<0.01). The area under the ROC curve values to discriminate chondrosarcoma from enchondroma were 0.876 and 0.826 for kurtosis and skewness in contrast-enhanced T1 (ceT1w), respectively; in non-contrast T1, values were 0.851 and 0.822 for entropy and UPP, respectively. The highest discriminatory power had kurtosis in ceT1w with a cut-off ≥3.15 to identify low-grade chondrosarcoma (82 % sensitivity, 91 % specificity, accuracy 86 %). MRI-based 3D texture analysis might be able to discriminate low-grade chondrosarcoma from enchondroma by a variety of texture parameters. (orig.)

  3. Texture analysis of cardiac cine magnetic resonance imaging to detect nonviable segments in patients with chronic myocardial infarction.

    Science.gov (United States)

    Larroza, Andrés; López-Lereu, María P; Monmeneu, José V; Gavara, Jose; Chorro, Francisco J; Bodí, Vicente; Moratal, David

    2018-04-01

    To investigate the ability of texture analysis to differentiate between infarcted nonviable, viable, and remote segments on cardiac cine magnetic resonance imaging (MRI). This retrospective study included 50 patients suffering chronic myocardial infarction. The data were randomly split into training (30 patients) and testing (20 patients) sets. The left ventricular myocardium was segmented according to the 17-segment model in both cine and late gadolinium enhancement (LGE) MRI. Infarcted myocardium regions were identified on LGE in short-axis views. Nonviable segments were identified as those showing LGE ≥ 50%, and viable segments those showing 0 cine images. A support vector machine (SVM) classifier was trained with different combination of texture features to obtain a model that provided optimal classification performance. The best classification on testing set was achieved with local binary patterns features using a 2D + t approach, in which the features are computed by including information of the time dimension available in cine sequences. The best overall area under the receiver operating characteristic curve (AUC) were: 0.849, sensitivity of 92% to detect nonviable segments, 72% to detect viable segments, and 85% to detect remote segments. Nonviable segments can be detected on cine MRI using texture analysis and this may be used as hypothesis for future research aiming to detect the infarcted myocardium by means of a gadolinium-free approach. © 2018 American Association of Physicists in Medicine.

  4. Whole-lesion ADC histogram and texture analysis in predicting recurrence of cervical cancer treated with CCRT.

    Science.gov (United States)

    Meng, Jie; Zhu, Lijing; Zhu, Li; Xie, Li; Wang, Huanhuan; Liu, Song; Yan, Jing; Liu, Baorui; Guan, Yue; He, Jian; Ge, Yun; Zhou, Zhengyang; Yang, Xiaofeng

    2017-11-03

    To explore the value of whole-lesion apparent diffusion coefficient (ADC) histogram and texture analysis in predicting tumor recurrence of advanced cervical cancer treated with concurrent chemo-radiotherapy (CCRT). 36 women with pathologically confirmed advanced cervical squamous carcinomas were enrolled in this prospective study. 3.0 T pelvic MR examinations including diffusion weighted imaging (b = 0, 800 s/mm 2 ) were performed before CCRT (pre-CCRT) and at the end of 2nd week of CCRT (mid-CCRT). ADC histogram and texture features were derived from the whole volume of cervical cancers. With a mean follow-up of 25 months (range, 11 ∼ 43), 10/36 (27.8%) patients ended with recurrence. Pre-CCRT 75th, 90th, correlation, autocorrelation and mid-CCRT ADC mean , 10th, 25th, 50th, 75th, 90th, autocorrelation can effectively differentiate the recurrence from nonrecurrence group with area under the curve ranging from 0.742 to 0.850 (P values range, 0.001 ∼ 0.038). Pre- and mid-treatment whole-lesion ADC histogram and texture analysis hold great potential in predicting tumor recurrence of advanced cervical cancer treated with CCRT.

  5. Decision Tree and Texture Analysis for Mapping Debris-Covered Glaciers in the Kangchenjunga Area, Eastern Himalaya

    Directory of Open Access Journals (Sweden)

    Adina Racoviteanu

    2012-10-01

    Full Text Available In this study we use visible, short-wave infrared and thermal Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER data validated with high-resolution Quickbird (QB and Worldview2 (WV2 for mapping debris cover in the eastern Himalaya using two independent approaches: (a a decision tree algorithm, and (b texture analysis. The decision tree algorithm was based on multi-spectral and topographic variables, such as band ratios, surface reflectance, kinetic temperature from ASTER bands 10 and 12, slope angle, and elevation. The decision tree algorithm resulted in 64 km2 classified as debris-covered ice, which represents 11% of the glacierized area. Overall, for ten glacier tongues in the Kangchenjunga area, there was an area difference of 16.2 km2 (25% between the ASTER and the QB areas, with mapping errors mainly due to clouds and shadows. Texture analysis techniques included co-occurrence measures, geostatistics and filtering in spatial/frequency domain. Debris cover had the highest variance of all terrain classes, highest entropy and lowest homogeneity compared to the other classes, for example a mean variance of 15.27 compared to 0 for clouds and 0.06 for clean ice. Results of the texture image for debris-covered areas were comparable with those from the decision tree algorithm, with 8% area difference between the two techniques.

  6. A novel method of estimating dose responses for polymer gels using texture analysis of scanning electron microscopy images.

    Directory of Open Access Journals (Sweden)

    Cheng-Ting Shih

    Full Text Available Polymer gels are regarded as a potential dosimeter for independent validation of absorbed doses in clinical radiotherapy. Several imaging modalities have been used to convert radiation-induced polymerization to absorbed doses from a macro-scale viewpoint. This study developed a novel dose conversion mechanism by texture analysis of scanning electron microscopy (SEM images. The modified N-isopropyl-acrylamide (NIPAM gels were prepared under normoxic conditions, and were administered radiation doses from 5 to 20 Gy. After freeze drying, the gel samples were sliced for SEM scanning with 50×, 500×, and 3500× magnifications. Four texture indices were calculated based on the gray level co-occurrence matrix (GLCM. The results showed that entropy and homogeneity were more suitable than contrast and energy as dose indices for higher linearity and sensitivity of the dose response curves. After parameter optimization, an R (2 value of 0.993 can be achieved for homogeneity using 500× magnified SEM images with 27 pixel offsets and no outlier exclusion. For dose verification, the percentage errors between the prescribed dose and the measured dose for 5, 10, 15, and 20 Gy were -7.60%, 5.80%, 2.53%, and -0.95%, respectively. We conclude that texture analysis can be applied to the SEM images of gel dosimeters to accurately convert micro-scale structural features to absorbed doses. The proposed method may extend the feasibility of applying gel dosimeters in the fields of diagnostic radiology and radiation protection.

  7. Texture profile analysis of yogurt as influenced by partially hydrolyzed guar gum and process variables.

    Science.gov (United States)

    Mudgil, Deepak; Barak, Sheweta; Khatkar, B S

    2017-11-01

    Effect of partially hydrolyzed guar gum (PHGG) level (1-5%), culture level (1.5-3.5%) and incubation time (4-8 h) on texture profile of yogurt was studied using response surface methodology. The fortification of partially hydrolyzed guar gum in yogurt decreased the firmness and gumminess while it increased the adhesiveness, cohesiveness and springiness of yogurt significantly at p  < 0.01. The culture level did not affect the textural properties of yogurt significantly except gumminess whereas textural properties of yogurt were negatively correlated with incubation time. The coefficient of determination for hardness/hardness, adhesiveness, cohesiveness, springiness and gumminess were 0.9216, 0.9397, 0.8914, 0.8971 and 0.9156, respectively, which revealed that the models obtained were significant as coefficient of determination value was close to one. The optimum conditions obtained were PHGG level 3.37%, culture level 1.96% and incubation time 5.96 h which leads to preparation of yogurt with desired textural characteristics.

  8. Texture Analysis of Recurrence Plots Based on Wavelets and PSO for Laryngeal Pathologies Detection.

    Science.gov (United States)

    Souza, Taciana A; Vieira, Vinícius J D; Correia, Suzete E N; Costa, Silvana L N C; de A Costa, Washington C; Souza, Micael A

    2015-01-01

    This paper deals with the discrimination between healthy and pathological speech signals using recurrence plots and wavelet transform with texture features. Approximation and detail coefficients are obtained from the recurrence plots using Haar wavelet transform, considering one decomposition level. The considered laryngeal pathologies are: paralysis, Reinke's edema and nodules. Accuracy rates above 86% were obtained by means of the employed method.

  9. Quantitative radiomics: impact of stochastic effects on textural feature analysis implies the need for standards.

    Science.gov (United States)

    Nyflot, Matthew J; Yang, Fei; Byrd, Darrin; Bowen, Stephen R; Sandison, George A; Kinahan, Paul E

    2015-10-01

    Image heterogeneity metrics such as textural features are an active area of research for evaluating clinical outcomes with positron emission tomography (PET) imaging and other modalities. However, the effects of stochastic image acquisition noise on these metrics are poorly understood. We performed a simulation study by generating 50 statistically independent PET images of the NEMA IQ phantom with realistic noise and resolution properties. Heterogeneity metrics based on gray-level intensity histograms, co-occurrence matrices, neighborhood difference matrices, and zone size matrices were evaluated within regions of interest surrounding the lesions. The impact of stochastic variability was evaluated with percent difference from the mean of the 50 realizations, coefficient of variation and estimated sample size for clinical trials. Additionally, sensitivity studies were performed to simulate the effects of patient size and image reconstruction method on the quantitative performance of these metrics. Complex trends in variability were revealed as a function of textural feature, lesion size, patient size, and reconstruction parameters. In conclusion, the sensitivity of PET textural features to normal stochastic image variation and imaging parameters can be large and is feature-dependent. Standards are needed to ensure that prospective studies that incorporate textural features are properly designed to measure true effects that may impact clinical outcomes.

  10. Differentiation of Uterine Leiomyosarcoma from Atypical Leiomyoma: Diagnostic Accuracy of Qualitative MR Imaging Features and Feasibility of Texture Analysis.

    Science.gov (United States)

    Lakhman, Yulia; Veeraraghavan, Harini; Chaim, Joshua; Feier, Diana; Goldman, Debra A; Moskowitz, Chaya S; Nougaret, Stephanie; Sosa, Ramon E; Vargas, Hebert Alberto; Soslow, Robert A; Abu-Rustum, Nadeem R; Hricak, Hedvig; Sala, Evis

    2017-07-01

    To investigate whether qualitative magnetic resonance (MR) features can distinguish leiomyosarcoma (LMS) from atypical leiomyoma (ALM) and assess the feasibility of texture analysis (TA). This retrospective study included 41 women (ALM = 22, LMS = 19) imaged with MRI prior to surgery. Two readers (R1, R2) evaluated each lesion for qualitative MR features. Associations between MR features and LMS were evaluated with Fisher's exact test. Accuracy measures were calculated for the four most significant features. TA was performed for 24 patients (ALM = 14, LMS = 10) with uniform imaging following lesion segmentation on axial T2-weighted images. Texture features were pre-selected using Wilcoxon signed-rank test with Bonferroni correction and analyzed with unsupervised clustering to separate LMS from ALM. Four qualitative MR features most strongly associated with LMS were nodular borders, haemorrhage, "T2 dark" area(s), and central unenhanced area(s) (p ≤ 0.0001 each feature/reader). The highest sensitivity [1.00 (95%CI:0.82-1.00)/0.95 (95%CI: 0.74-1.00)] and specificity [0.95 (95%CI:0.77-1.00)/1.00 (95%CI:0.85-1.00)] were achieved for R1/R2, respectively, when a lesion had ≥3 of these four features. Sixteen texture features differed significantly between LMS and ALM (p-values: feasible. • Four qualitative MR features demonstrated the strongest statistical association with LMS. • Combination of ≥3 these features could accurately differentiate LMS from ALM. • Texture analysis was a feasible semi-automated approach for lesion categorization.

  11. Texture analysis of {sup 18}F-FDG PET/CT to predict tumour response and prognosis of patients with esophageal cancer treated by chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nakajo, Masatoyo; Jinguji, Megumi; Nakabeppu, Yoshiaki; Higashi, Ryutarou; Fukukura, Yoshihiko; Yoshiura, Takashi [Kagoshima University, Department of Radiology, Graduate School of Medical and Dental Sciences, Kagoshima (Japan); Nakajo, Masayuki [Nanpuh Hospital, Department of Radiology, Kagoshima (Japan); Sasaki, Ken; Uchikado, Yasuto; Natsugoe, Shoji [Kagoshima University, Department of Digestive Surgery, Breast and Thyroid Surgery, Graduate School of Medical and Dental Sciences, Kagoshima (Japan)

    2017-02-15

    This retrospective study was done to examine whether the heterogeneity in primary tumour F-18-fluorodeoxyglucose ({sup 18}F-FDG) distribution can predict tumour response and prognosis of patients with esophageal cancer treated by chemoradiotherapy (CRT). The enrolled 52 patients with esophageal cancer underwent {sup 18}F-FDG-PET/CT studies before CRT. SUVmax, SUVmean, metabolic tumour volume (MTV, SUV ≥ 2.5), total lesion glycolysis (TLG) and six heterogeneity parameters assessed by texture analysis were obtained. Patients were classified as responders or non-responders according to Response Evaluation Criteria in Solid Tumors. Progression-free survival (PFS) and overall survival (OS) were calculated by the Kaplan-Meier method. Prognostic significance was assessed by Cox proportional hazards analysis. Thirty four non-responders showed significantly higher MTV (p = 0.006), TLG (p = 0.007), intensity variability (IV; p = 0.003) and size-zone variability (SZV; p = 0.004) than 18 responders. The positive and negative predictive values for non-responders were 77 % and 69 % in MTV, 76 % and 100 % in TLG, 78 % and 67 % in IV and 78 % and 82 % in SZV, respectively. Although PFS and OS were significantly shorter in patients with high MTV (PFS, p = 0.018; OS, p = 0.014), TLG (PFS, p = 0.009; OS, p = 0.025), IV (PFS, p = 0.013; OS, p = 0.007) and SZV (PFS, p = 0.010; OS, p = 0.007) at univariate analysis, none of them was an independent factor, while lymph node status, stage and tumour response status were independent factors at multivariate analysis. Texture features IV and SZV, and volumetric parameters MTV and TLG can predict tumour response, but all of them have limited value in prediction of prognosis of patients with esophageal cancer treated by CRT. (orig.)

  12. Computerized image analysis: Texture-field orientation method for pectoral muscle identification on MLO-view mammograms

    International Nuclear Information System (INIS)

    Zhou Chuan; Wei Jun; Chan, Heang-Ping; Paramagul, Chintana; Hadjiiski, Lubomir M.; Sahiner, Berkman; Douglas, Julie A.

    2010-01-01

    Purpose: To develop a new texture-field orientation (TFO) method that combines a priori knowledge, local and global information for the automated identification of pectoral muscle on mammograms. Methods: The authors designed a gradient-based directional kernel (GDK) filter to enhance the linear texture structures, and a gradient-based texture analysis to extract a texture orientation image that represented the dominant texture orientation at each pixel. The texture orientation image was enhanced by a second GDK filter for ridge point extraction. The extracted ridge points were validated and the ridges that were less likely to lie on the pectoral boundary were removed automatically. A shortest-path finding method was used to generate a probability image that represented the likelihood that each remaining ridge point lay on the true pectoral boundary. Finally, the pectoral boundary was tracked by searching for the ridge points with the highest probability lying on the pectoral boundary. A data set of 130 MLO-view digitized film mammograms (DFMs) from 65 patients was used to train the TFO algorithm. An independent data set of 637 MLO-view DFMs from 562 patients was used to evaluate its performance. Another independent data set of 92 MLO-view full field digital mammograms (FFDMs) from 92 patients was used to assess the adaptability of the TFO algorithm to FFDMs. The pectoral boundary detection accuracy of the TFO method was quantified by comparison with an experienced radiologist's manually drawn pectoral boundary using three performance metrics: The percent overlap area (POA), the Hausdorff distance (Hdist), and the average distance (AvgDist). Results: The mean and standard deviation of POA, Hdist, and AvgDist were 95.0±3.6%, 3.45±2.16 mm, and 1.12±0.82 mm, respectively. For the POA measure, 91.5%, 97.3%, and 98.9% of the computer detected pectoral muscles had POA larger than 90%, 85%, and 80%, respectively. For the distance measures, 85.4% and 98.0% of the

  13. Texture-Based Analysis of 100 MR Examinations of Head and Neck Tumors - Is It Possible to Discriminate Between Benign and Malignant Masses in a Multicenter Trial?

    Science.gov (United States)

    Fruehwald-Pallamar, J; Hesselink, J R; Mafee, M F; Holzer-Fruehwald, L; Czerny, C; Mayerhoefer, M E

    2016-02-01

    To evaluate whether texture-based analysis of standard MRI sequences can help in the discrimination between benign and malignant head and neck tumors. The MR images of 100 patients with a histologically clarified head or neck mass, from two different institutions, were analyzed. Texture-based analysis was performed using texture analysis software, with region of interest measurements for 2 D and 3 D evaluation independently for all axial sequences. COC, RUN, GRA, ARM, and WAV features were calculated for all ROIs. 10 texture feature subsets were used for a linear discriminant analysis, in combination with k-nearest-neighbor classification. Benign and malignant tumors were compared with regard to texture-based values. There were differences in the images from different field-strength scanners, as well as from different vendors. For the differentiation of benign and malignant tumors, we found differences on STIR and T2-weighted images for 2 D, and on contrast-enhanced T1-TSE with fat saturation for 3 D evaluation. In a separate analysis of the subgroups 1.5 and 3 Tesla, more discriminating features were found. Texture-based analysis is a useful tool in the discrimination of benign and malignant tumors when performed on one scanner with the same protocol. We cannot recommend this technique for the use of multicenter studies with clinical data. 2 D/3 D texture-based analysis can be performed in head and neck tumors. Texture-based analysis can differentiate between benign and malignant masses. Analyzed MR images should originate from one scanner with an identical protocol. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Texture-based analysis of 100 MR examinations of head and neck tumors. Is it possible to discriminate between benign and malignant masses in a multicenter trial?

    International Nuclear Information System (INIS)

    Fruehwald-Pallamar, J.; Czerny, C.; Hesselink, J.R.; Mafee, M.F.; Holzer-Fruehwald, L.; Mayerhoefer, M.E.

    2016-01-01

    To evaluate whether texture-based analysis of standard MRI sequences can help in the discrimination between benign and malignant head and neck tumors. The MR images of 100 patients with a histologically clarified head or neck mass, from two different institutions, were analyzed. Texture-based analysis was performed using texture analysis software, with region of interest measurements for 2D and 3D evaluation independently for all axial sequences. COC, RUN, GRA, ARM, and WAV features were calculated for all ROIs. 10 texture feature subsets were used for a linear discriminant analysis, in combination with k-nearest-neighbor classification. Benign and malignant tumors were compared with regard to texture-based values. There were differences in the images from different field-strength scanners, as well as from different vendors. For the differentiation of benign and malignant tumors, we found differences on STIR and T2-weighted images for 2D, and on contrast-enhanced T1-TSE with fat saturation for 3D evaluation. In a separate analysis of the subgroups 1.5 and 3 Tesla, more discriminating features were found. Texture-based analysis is a useful tool in the discrimination of benign and malignant tumors when performed on one scanner with the same protocol. We cannot recommend this technique for the use of multicenter studies with clinical data.

  15. Texture-based analysis of 100 MR examinations of head and neck tumors. Is it possible to discriminate between benign and malignant masses in a multicenter trial?

    Energy Technology Data Exchange (ETDEWEB)

    Fruehwald-Pallamar, J.; Czerny, C. [Medical University of Vienna (Austria). Subdiv. of Neuroradiology and Musculoskeletal Radiology; Hesselink, J.R.; Mafee, M.F. [UCSD Medical Center, San Diego, CA (United States). Dept. of Radiology; Holzer-Fruehwald, L.; Mayerhoefer, M.E. [Medical University of Vienna (Austria). Dept. of Biomedical Imaging and Image-Guided Therapy

    2016-02-15

    To evaluate whether texture-based analysis of standard MRI sequences can help in the discrimination between benign and malignant head and neck tumors. The MR images of 100 patients with a histologically clarified head or neck mass, from two different institutions, were analyzed. Texture-based analysis was performed using texture analysis software, with region of interest measurements for 2D and 3D evaluation independently for all axial sequences. COC, RUN, GRA, ARM, and WAV features were calculated for all ROIs. 10 texture feature subsets were used for a linear discriminant analysis, in combination with k-nearest-neighbor classification. Benign and malignant tumors were compared with regard to texture-based values. There were differences in the images from different field-strength scanners, as well as from different vendors. For the differentiation of benign and malignant tumors, we found differences on STIR and T2-weighted images for 2D, and on contrast-enhanced T1-TSE with fat saturation for 3D evaluation. In a separate analysis of the subgroups 1.5 and 3 Tesla, more discriminating features were found. Texture-based analysis is a useful tool in the discrimination of benign and malignant tumors when performed on one scanner with the same protocol. We cannot recommend this technique for the use of multicenter studies with clinical data.

  16. Trabecular morphometry by fractal signature analysis is a novel marker of osteoarthritis progression.

    Science.gov (United States)

    Kraus, Virginia Byers; Feng, Sheng; Wang, ShengChu; White, Scott; Ainslie, Maureen; Brett, Alan; Holmes, Anthony; Charles, H Cecil

    2009-12-01

    To evaluate the effectiveness of using subchondral bone texture observed on a radiograph taken at baseline to predict progression of knee osteoarthritis (OA) over a 3-year period. A total of 138 participants in the Prediction of Osteoarthritis Progression study were evaluated at baseline and after 3 years. Fractal signature analysis (FSA) of the medial subchondral tibial plateau was performed on fixed flexion radiographs of 248 nonreplaced knees, using a commercially available software tool. OA progression was defined as a change in joint space narrowing (JSN) or osteophyte formation of 1 grade according to a standardized knee atlas. Statistical analysis of fractal signatures was performed using a new model based on correlating the overall shape of a fractal dimension curve with radius. Fractal signature of the medial tibial plateau at baseline was predictive of medial knee JSN progression (area under the curve [AUC] 0.75, of a receiver operating characteristic curve) but was not predictive of osteophyte formation or progression of JSN in the lateral compartment. Traditional covariates (age, sex, body mass index, knee pain), general bone mineral content, and joint space width at baseline were no more effective than random variables for predicting OA progression (AUC 0.52-0.58). The predictive model with maximum effectiveness combined fractal signature at baseline, knee alignment, traditional covariates, and bone mineral content (AUC 0.79). We identified a prognostic marker of OA that is readily extracted from a plain radiograph using FSA. Although the method needs to be validated in a second cohort, our results indicate that the global shape approach to analyzing these data is a potentially efficient means of identifying individuals at risk of knee OA progression.

  17. Characterization of Adrenal Lesions on Unenhanced MRI Using Texture Analysis: A Machine-Learning Approach.

    Science.gov (United States)

    Romeo, Valeria; Maurea, Simone; Cuocolo, Renato; Petretta, Mario; Mainenti, Pier Paolo; Verde, Francesco; Coppola, Milena; Dell'Aversana, Serena; Brunetti, Arturo

    2018-01-17

    Adrenal adenomas (AA) are the most common benign adrenal lesions, often characterized based on intralesional fat content as either lipid-rich (LRA) or lipid-poor (LPA). The differentiation of AA, particularly LPA, from nonadenoma adrenal lesions (NAL) may be challenging. Texture analysis (TA) can extract quantitative parameters from MR images. Machine learning is a technique for recognizing patterns that can be applied to medical images by identifying the best combination of TA features to create a predictive model for the diagnosis of interest. To assess the diagnostic efficacy of TA-derived parameters extracted from MR images in characterizing LRA, LPA, and NAL using a machine-learning approach. Retrospective, observational study. Sixty MR examinations, including 20 LRA, 20 LPA, and 20 NAL. Unenhanced T 1 -weighted in-phase (IP) and out-of-phase (OP) as well as T 2 -weighted (T 2 -w) MR images acquired at 3T. Adrenal lesions were manually segmented, placing a spherical volume of interest on IP, OP, and T 2 -w images. Different selection methods were trained and tested using the J48 machine-learning classifiers. The feature selection method that obtained the highest diagnostic performance using the J48 classifier was identified; the diagnostic performance was also compared with that of a senior radiologist by means of McNemar's test. A total of 138 TA-derived features were extracted; among these, four features were selected, extracted from the IP (Short_Run_High_Gray_Level_Emphasis), OP (Mean_Intensity and Maximum_3D_Diameter), and T 2 -w (Standard_Deviation) images; the J48 classifier obtained a diagnostic accuracy of 80%. The expert radiologist obtained a diagnostic accuracy of 73%. McNemar's test did not show significant differences in terms of diagnostic performance between the J48 classifier and the expert radiologist. Machine learning conducted on MR TA-derived features is a potential tool to characterize adrenal lesions. 4 Technical Efficacy: Stage 2 J

  18. Assessing breast cancer masking risk with automated texture analysis in full field digital mammography

    DEFF Research Database (Denmark)

    Kallenberg, Michiel Gijsbertus J; Lillholm, Martin; Diao, Pengfei

    2015-01-01

    PURPOSE The goal of this work is to develop a method to assess the risk of breast cancer masking, based on image characteristics beyond breast density. METHOD AND MATERIALS From the Dutch breast cancer screening program we collected 285 screen detected cancers, and 109 cancers that were screen...... negative and subsequently appeared as interval cancers. To obtain mammograms without cancerous tissue, we took the contralateral mammograms. We developed a novel machine learning based method called convolutional sparse autoencoder to characterize mammographic texture. The reason for focusing...... status in a five-fold cross validation. To assess the interaction of the texture scores with breast density, Volpara Density Grade (VDG) was determined for each image using Volpara, Matakina Technology, New Zealand. RESULTS We grouped women into low (VDG 1/2) versus high (VDG 3/4) dense, and low...

  19. Assessing breast cancer masking risk in full field digital mammography with automated texture analysis

    DEFF Research Database (Denmark)

    Kallenberg, Michiel Gijsbertus J; Lillholm, Martin; Diao, Pengfei

    2015-01-01

    Purpose: The goal of this work is to develop a method to assess the risk of breast cancer masking, based on image characteristics beyond breast density. Method: From the Dutch breast cancer screening program we collected 285 screen detected cancers, and 109 cancers that were screen negative...... and subsequently appeared as interval cancers. To obtain mammograms without cancerous tissue, we took the contralateral mammograms. We developed a novel machine learning based method called convolutional sparse autoencoder to characterize mammographic texture. The method was trained and tested on raw mammograms...... to determine cancer detection status in a five-fold cross validation. To assess the interaction of the texture scores with breast density, Volpara Density Grade was determined for each image. Results: We grouped women into low (VDG 1/2) versus high (VDG 3/4) dense, and low (Quartile 1/2) versus high (Q 3...

  20. The distribution function of crystalline orientation's usefulness in crystallographic texture analysis

    International Nuclear Information System (INIS)

    Hermida, J.D.; Pochettino, A.A.

    1982-01-01

    The theoretical fundaments of the Distribution Function of Crystalline Orientations (DFCO) are described and this method is compared with the usual description of the crystallographic texture by direct pole figures. Such function is applied to the study of a Zry-4 sample obtained from a tube belonging to a CANDU type fuel element. The DFCO is obtained from the pole figures (0002), (101-bar0) and (101-bar1). The results show the existence of six fundamental components of texture, which are enunciated below, in decreasing order of importance: (2-bar115) ; (3-bar128) ; (1-bar013) ; (2-bar114) ; (0001) ; (0001) . A much more complete view of the crystals' orientation state of such sample can be obtained by analyzing the weight and the distribution of the different components. (M.E.L.) [es

  1. Seismic texture classification. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Vinther, R.

    1997-12-31

    The seismic texture classification method, is a seismic attribute that can both recognize the general reflectivity styles and locate variations from these. The seismic texture classification performs a statistic analysis for the seismic section (or volume) aiming at describing the reflectivity. Based on a set of reference reflectivities the seismic textures are classified. The result of the seismic texture classification is a display of seismic texture categories showing both the styles of reflectivity from the reference set and interpolations and extrapolations from these. The display is interpreted as statistical variations in the seismic data. The seismic texture classification is applied to seismic sections and volumes from the Danish North Sea representing both horizontal stratifications and salt diapers. The attribute succeeded in recognizing both general structure of successions and variations from these. Also, the seismic texture classification is not only able to display variations in prospective areas (1-7 sec. TWT) but can also be applied to deep seismic sections. The seismic texture classification is tested on a deep reflection seismic section (13-18 sec. TWT) from the Baltic Sea. Applied to this section the seismic texture classification succeeded in locating the Moho, which could not be located using conventional interpretation tools. The seismic texture classification is a seismic attribute which can display general reflectivity styles and deviations from these and enhance variations not found by conventional interpretation tools. (LN)

  2. Analysis of SURRGO Data and Obtaining Soil Texture Classifications for Simulating Hydrologic Processes

    Science.gov (United States)

    2016-07-01

    the general texture classifications. 2. Another source for soil information, such as the Food and Agriculture Organization of the United Nations (FAO...is to use another soils dataset that contains soil properties for the areas of interest, such as the Digital Soil Map of the World provided by the...www.nrcs.usda.gov/wps/portal/nrcs/main/soils/survey/ NOTE: The contents of this technical note are not to be used for advertising

  3. Nonlinear Progressive Collapse Analysis Including Distributed Plasticity

    Directory of Open Access Journals (Sweden)

    Mohamed Osama Ahmed

    2016-01-01

    Full Text Available This paper demonstrates the effect of incorporating distributed plasticity in nonlinear analytical models used to assess the potential for progressive collapse of steel framed regular building structures. Emphasis on this paper is on the deformation response under the notionally removed column, in a typical Alternate Path (AP method. The AP method employed in this paper is based on the provisions of the Unified Facilities Criteria – Design of Buildings to Resist Progressive Collapse, developed and updated by the U.S. Department of Defense [1]. The AP method is often used for to assess the potential for progressive collapse of building structures that fall under Occupancy Category III or IV. A case study steel building is used to examine the effect of incorporating distributed plasticity, where moment frames were used on perimeter as well as the interior of the three dimensional structural system. It is concluded that the use of moment resisting frames within the structural system will enhance resistance to progressive collapse through ductile deformation response and that it is conserative to ignore the effects of distributed plasticity in determining peak displacement response under the notionally removed column.

  4. Statistical analysis of texture in trunk images for biometric identification of tree species.

    Science.gov (United States)

    Bressane, Adriano; Roveda, José A F; Martins, Antônio C G

    2015-04-01

    The identification of tree species is a key step for sustainable management plans of forest resources, as well as for several other applications that are based on such surveys. However, the present available techniques are dependent on the presence of tree structures, such as flowers, fruits, and leaves, limiting the identification process to certain periods of the year. Therefore, this article introduces a study on the application of statistical parameters for texture classification of tree trunk images. For that, 540 samples from five Brazilian native deciduous species were acquired and measures of entropy, uniformity, smoothness, asymmetry (third moment), mean, and standard deviation were obtained from the presented textures. Using a decision tree, a biometric species identification system was constructed and resulted to a 0.84 average precision rate for species classification with 0.83accuracy and 0.79 agreement. Thus, it can be considered that the use of texture presented in trunk images can represent an important advance in tree identification, since the limitations of the current techniques can be overcome.

  5. Automated Texture Analysis and Determination of Fibre Orientation of Heart Tissue: A Morphometric Study.

    Science.gov (United States)

    Zach, Bernhard; Hofer, Ernst; Asslaber, Martin; Ahammer, Helmut

    2016-01-01

    The human heart has a heterogeneous structure, which is characterized by different cell types and their spatial configurations. The physical structure, especially the fibre orientation and the interstitial fibrosis, determines the electrical excitation and in further consequence the contractility in macroscopic as well as in microscopic areas. Modern image processing methods and parameters could be used to describe the image content and image texture. In most cases the description of the texture is not satisfying because the fibre orientation, detected with common algorithms, is biased by elements such as fibrocytes or endothelial nuclei. The goal of this work is to figure out if cardiac tissue can be analysed and classified on a microscopic level by automated image processing methods with a focus on an accurate detection of the fibre orientation. Quantitative parameters for identification of textures of different complexity or pathological attributes inside the heart were determined. The focus was set on the detection of the fibre orientation, which was calculated on the basis of the cardiomyocytes' nuclei. It turned out that the orientation of these nuclei corresponded with a high precision to the fibre orientation in the image plane. Additionally, these nuclei also indicated very well the inclination of the fibre.

  6. Multi-phase EBSD mapping and local texture analysis in NdFeB sintered magnets

    Energy Technology Data Exchange (ETDEWEB)

    Woodcock, T.G., E-mail: t.woodcock@ifw-dresden.de [IFW Dresden, Institute for Metallic Materials, PO Box 270116, 01171 Dresden (Germany); Gutfleisch, O. [IFW Dresden, Institute for Metallic Materials, PO Box 270116, 01171 Dresden (Germany)

    2011-02-15

    A combination of electron backscatter diffraction and energy-dispersive X-ray spectroscopy has been used to identify the crystal structure and composition of all the phases present in commercially available NdFeB sintered magnets and to map their spatial distribution. The Nd{sub 2}Fe{sub 14}B and NdO grains were shown to have low defect densities. The fcc Nd-rich and Nd{sub 2}O{sub 3} grains had intra-grain misorientation angles of up to 14{sup o}, which was shown to be due to defects. Large numbers ({approx}100) of data points for each phase were used to study texture in the NdO, Nd{sub 2}O{sub 3} and Nd{sub 2}Fe{sub 14}B phases. The Nd{sub 2}Fe{sub 14}B grains exhibited a <0 0 1> fibre texture. The Nd oxide phases showed no strong texture, which implied that no strongly preferred orientation relationships between those phases and Nd{sub 2}Fe{sub 14}B exist. The result was shown to be valid for optimally annealed samples exhibiting high coercivity and as-sintered samples exhibiting low coercivity.

  7. Texture analysis of a friction stir processed 6061-T6 aluminum alloy using neutron diffraction

    International Nuclear Information System (INIS)

    Woo, W.; Choo, H.; Brown, D.W.; Vogel, S.C.; Liaw, P.K.; Feng, Z.

    2006-01-01

    Time-of-flight neutron diffraction was used to investigate the texture changes in friction stir-processed (FSP) 6061-T6 aluminum alloy plates. Two different specimens were prepared with the purpose of separating the effects of frictional heating and severe plastic deformation on the changes of the preferred orientation in the as-received rolled plates: a plate processed with both stirring pin and tool shoulder, i.e., a regular FSP plate subjected to both severe plastic deformation and frictional heating (Case 1); and a plate processed only with the tool shoulder, i.e., subjected mainly to frictional heating (Case 2). The diffraction peak intensities provide insights into the texture variations at various locations across the centerline and through the thickness of the FSP plates. Comparison of the texture variations between Cases 1 and 2 clearly shows that the severe plastic deformation from the stirring pin affects the preferred orientation during the FSP, while heating alone from the tool shoulder has little effect

  8. Temporal analysis of intratumoral metabolic heterogeneity characterized by textural features in cervical cancer.

    Science.gov (United States)

    Yang, Fei; Thomas, Maria A; Dehdashti, Farrokh; Grigsby, Perry W

    2013-05-01

    The aim of this pilot study was to explore heterogeneity in the temporal behavior of intratumoral [(18)F]fluorodeoxyglucose (FDG) accumulation at a regional scale in patients with cervical cancer undergoing chemoradiotherapy. Included in the study were 20 patients with FIGO stages IB1 to IVA cervical cancer treated with combined chemoradiotherapy. Patients underwent FDG PET/CT before treatment, during weeks 2 and 4 of treatment, and 12 weeks after completion of therapy. Patients were classified based on response to therapy as showing a complete metabolic response (CMR), a partial metabolic response (PMR), or residual disease and the development of new disease (NEW). Based on the presence of residual primary tumor following therapy, patients were divided into two groups, CMR and PMR/NEW. Temporal profiles of intratumoral FDG heterogeneity as characterized by textural features at a regional scale were assessed and compared with those of the standardized uptake value (SUV) indices (SUVmax and SUVmean) within the context of differentiating response groups. Textural features at a regional scale with emphasis on characterizing contiguous regions of high uptake in tumors decreased significantly with time (P features describing contiguous regions of low uptake along with those measuring the nonuniformity of contiguous isointense regions in tumors exhibited significant temporal changes in the PMR/NEW group (P textural features may provide an adjunctive or alternative option for understanding tumor response to chemoradiotherapy and interpreting FDG accumulation dynamics in patients with malignant cervical tumors during the course of the disease.

  9. SU-E-J-249: Characterization of Gynecological Tumor Heterogeneity Using Texture Analysis in the Context of An 18F-FDG PET Adaptive Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Nawrocki, J [Duke University Medical Physics Graduate Program, Durham, NC (United States); Chino, J; Craciunescu, O [Duke University Medical Center Department of Radiation Oncology, Durham, NC (United States); Das, S [University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2015-06-15

    Purpose: We propose a method to examine gynecological tumor heterogeneity using texture analysis in the context of an adaptive PET protocol in order to establish if texture metrics from baseline PET-CT predict tumor response better than SUV metrics alone as well as determine texture features correlating with tumor response during radiation therapy. Methods: This IRB approved protocol included 29 women with node positive gynecological cancers visible on FDG-PET treated with EBRT to the PET positive nodes. A baseline and intra-treatment PET-CT was obtained. Tumor outcome was determined based on RECIST on posttreatment PET-CT. Primary GTVs were segmented using 40% threshold and a semi-automatic gradient-based contouring tool, PET Edge (MIM Software Inc., Cleveland, OH). SUV histogram features, Metabolic Volume (MV), and Total Lesion Glycolysis (TLG) were calculated. Four 3D texture matrices describing local and regional relationships between voxel intensities in the GTV were generated: co-occurrence, run length, size zone, and neighborhood difference. From these, 39 texture features were calculated. Prognostic power of baseline features derived from gradientbased and threshold GTVs were determined using the Wilcoxon rank-sum test. Receiver Operating Characteristics and logistic regression was performed using JMP (SAS Institute Inc., Cary, NC) to find probabilities of predicting response. Changes in features during treatment were determined using the Wilcoxon signed-rank test. Results: Of the 29 patients, there were 16 complete responders, 7 partial responders, and 6 non-responders. Comparing CR/PR vs. NR for gradient-based GTVs, 7 texture values, TLG, and SUV kurtosis had a p < 0.05. Threshold GTVs yielded 4 texture features and TLG with p < 0.05. From baseline to intra-treatment, 14 texture features, SUVmean, SUVmax, MV, and TLG changed with p < 0.05. Conclusion: Texture analysis of PET imaged gynecological tumors is an effective method for early prognosis and should

  10. SU-E-J-249: Characterization of Gynecological Tumor Heterogeneity Using Texture Analysis in the Context of An 18F-FDG PET Adaptive Protocol

    International Nuclear Information System (INIS)

    Nawrocki, J; Chino, J; Craciunescu, O; Das, S

    2015-01-01

    Purpose: We propose a method to examine gynecological tumor heterogeneity using texture analysis in the context of an adaptive PET protocol in order to establish if texture metrics from baseline PET-CT predict tumor response better than SUV metrics alone as well as determine texture features correlating with tumor response during radiation therapy. Methods: This IRB approved protocol included 29 women with node positive gynecological cancers visible on FDG-PET treated with EBRT to the PET positive nodes. A baseline and intra-treatment PET-CT was obtained. Tumor outcome was determined based on RECIST on posttreatment PET-CT. Primary GTVs were segmented using 40% threshold and a semi-automatic gradient-based contouring tool, PET Edge (MIM Software Inc., Cleveland, OH). SUV histogram features, Metabolic Volume (MV), and Total Lesion Glycolysis (TLG) were calculated. Four 3D texture matrices describing local and regional relationships between voxel intensities in the GTV were generated: co-occurrence, run length, size zone, and neighborhood difference. From these, 39 texture features were calculated. Prognostic power of baseline features derived from gradientbased and threshold GTVs were determined using the Wilcoxon rank-sum test. Receiver Operating Characteristics and logistic regression was performed using JMP (SAS Institute Inc., Cary, NC) to find probabilities of predicting response. Changes in features during treatment were determined using the Wilcoxon signed-rank test. Results: Of the 29 patients, there were 16 complete responders, 7 partial responders, and 6 non-responders. Comparing CR/PR vs. NR for gradient-based GTVs, 7 texture values, TLG, and SUV kurtosis had a p < 0.05. Threshold GTVs yielded 4 texture features and TLG with p < 0.05. From baseline to intra-treatment, 14 texture features, SUVmean, SUVmax, MV, and TLG changed with p < 0.05. Conclusion: Texture analysis of PET imaged gynecological tumors is an effective method for early prognosis and should

  11. Radiation injury vs. recurrent brain metastasis: combining textural feature radiomics analysis and standard parameters may increase 18F-FET PET accuracy without dynamic scans.

    Science.gov (United States)

    Lohmann, Philipp; Stoffels, Gabriele; Ceccon, Garry; Rapp, Marion; Sabel, Michael; Filss, Christian P; Kamp, Marcel A; Stegmayr, Carina; Neumaier, Bernd; Shah, Nadim J; Langen, Karl-Josef; Galldiks, Norbert

    2017-07-01

    We investigated the potential of textural feature analysis of O-(2-[ 18 F]fluoroethyl)-L-tyrosine ( 18 F-FET) PET to differentiate radiation injury from brain metastasis recurrence. Forty-seven patients with contrast-enhancing brain lesions (n = 54) on MRI after radiotherapy of brain metastases underwent dynamic 18 F-FET PET. Tumour-to-brain ratios (TBRs) of 18 F-FET uptake and 62 textural parameters were determined on summed images 20-40 min post-injection. Tracer uptake kinetics, i.e., time-to-peak (TTP) and patterns of time-activity curves (TAC) were evaluated on dynamic PET data from 0-50 min post-injection. Diagnostic accuracy of investigated parameters and combinations thereof to discriminate between brain metastasis recurrence and radiation injury was compared. Diagnostic accuracy increased from 81 % for TBR mean alone to 85 % when combined with the textural parameter Coarseness or Short-zone emphasis. The accuracy of TBR max alone was 83 % and increased to 85 % after combination with the textural parameters Coarseness, Short-zone emphasis, or Correlation. Analysis of TACs resulted in an accuracy of 70 % for kinetic pattern alone and increased to 83 % when combined with TBR max . Textural feature analysis in combination with TBRs may have the potential to increase diagnostic accuracy for discrimination between brain metastasis recurrence and radiation injury, without the need for dynamic 18 F-FET PET scans. • Textural feature analysis provides quantitative information about tumour heterogeneity • Textural features help improve discrimination between brain metastasis recurrence and radiation injury • Textural features might be helpful to further understand tumour heterogeneity • Analysis does not require a more time consuming dynamic PET acquisition.

  12. Statistical-techniques-based computer-aided diagnosis (CAD) using texture feature analysis: application in computed tomography (CT) imaging to fatty liver disease

    Science.gov (United States)

    Chung, Woon-Kwan; Park, Hyong-Hu; Im, In-Chul; Lee, Jae-Seung; Goo, Eun-Hoe; Dong, Kyung-Rae

    2012-09-01

    This paper proposes a computer-aided diagnosis (CAD) system based on texture feature analysis and statistical wavelet transformation technology to diagnose fatty liver disease with computed tomography (CT) imaging. In the target image, a wavelet transformation was performed for each lesion area to set the region of analysis (ROA, window size: 50 × 50 pixels) and define the texture feature of a pixel. Based on the extracted texture feature values, six parameters (average gray level, average contrast, relative smoothness, skewness, uniformity, and entropy) were determined to calculate the recognition rate for a fatty liver. In addition, a multivariate analysis of the variance (MANOVA) method was used to perform a discriminant analysis to verify the significance of the extracted texture feature values and the recognition rate for a fatty liver. According to the results, each texture feature value was significant for a comparison of the recognition rate for a fatty liver ( p fatty liver had the same scale as that for the F-value, showing 100% (average gray level) at the maximum and 80% (average contrast) at the minimum. Therefore, the recognition rate is believed to be a useful clinical value for the automatic detection and computer-aided diagnosis (CAD) using the texture feature value. Nevertheless, further study on various diseases and singular diseases will be needed in the future.

  13. Systems analysis department annual progress report 1986

    International Nuclear Information System (INIS)

    Grohnheit, P.E.; Larsen, H.; Vestergaard, N.K.

    1987-02-01

    The report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1986. The activities may be classified as energy systems analysis and risk and reliability analysis. The report includes a list of staff members. (author)

  14. SU-D-BRA-06: Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features

    International Nuclear Information System (INIS)

    Sorensen, J; Duran, C; Stingo, F; Wei, W; Rao, A; Zhang, L; Court, L; Erasmus, J; Godoy, M

    2015-01-01

    Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Level Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were

  15. SU-D-BRA-06: Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features

    Energy Technology Data Exchange (ETDEWEB)

    Sorensen, J; Duran, C; Stingo, F; Wei, W; Rao, A; Zhang, L; Court, L; Erasmus, J; Godoy, M [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Level Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were

  16. Visual Progression Analysis of Student Records Data

    OpenAIRE

    Raji, Mohammad; Duggan, John; DeCotes, Blaise; Huang, Jian; Zanden, Bradley Vander

    2017-01-01

    University curriculum, both on a campus level and on a per-major level, are affected in a complex way by many decisions of many administrators and faculty over time. As universities across the United States share an urgency to significantly improve student success and success retention, there is a pressing need to better understand how the student population is progressing through the curriculum, and how to provide better supporting infrastructure and refine the curriculum for the purpose of ...

  17. The brass-type texture and its deviation from the copper-type texture

    DEFF Research Database (Denmark)

    Leffers, Torben; Ray, R.K.

    2009-01-01

    Our basic aim with the present review is to address the classical problem of the “fcc rolling texture transition” – the fact that fcc materials may, depending on material parameters and rolling conditions, develop two different types of rolling textures, the copper-type texture and the brass...... the subject and sketch our approach for dealing with it. We then recapitulate the decisive progress made during the nineteen sixties in the empirical description of the fcc rolling texture transition and in lining up a number of possible explanations. Then follows a section about experimental investigations...... of the brass-type texture after the nineteen sixties covering texture measurements and microstructural investigations. The main observations are: (1) The brass-type texture deviates from the copper-type texture from an early stage of texture development. (2) Deformation twinning has a decisive effect...

  18. Introduction of High Throughput Magnetic Resonance T2-Weighted Image Texture Analysis for WHO Grade 2 and 3 Gliomas.

    Directory of Open Access Journals (Sweden)

    Manabu Kinoshita

    Full Text Available Reports have suggested that tumor textures presented on T2-weighted images correlate with the genetic status of glioma. Therefore, development of an image analyzing framework that is capable of objective and high throughput image texture analysis for large scale image data collection is needed. The current study aimed to address the development of such a framework by introducing two novel parameters for image textures on T2-weighted images, i.e., Shannon entropy and Prewitt filtering. Twenty-two WHO grade 2 and 28 grade 3 glioma patients were collected whose pre-surgical MRI and IDH1 mutation status were available. Heterogeneous lesions showed statistically higher Shannon entropy than homogenous lesions (p = 0.006 and ROC curve analysis proved that Shannon entropy on T2WI was a reliable indicator for discrimination of homogenous and heterogeneous lesions (p = 0.015, AUC = 0.73. Lesions with well-defined borders exhibited statistically higher Edge mean and Edge median values using Prewitt filtering than those with vague lesion borders (p = 0.0003 and p = 0.0005 respectively. ROC curve analysis also proved that both Edge mean and median values were promising indicators for discrimination of lesions with vague and well defined borders and both Edge mean and median values performed in a comparable manner (p = 0.0002, AUC = 0.81 and p < 0.0001, AUC = 0.83, respectively. Finally, IDH1 wild type gliomas showed statistically lower Shannon entropy on T2WI than IDH1 mutated gliomas (p = 0.007 but no difference was observed between IDH1 wild type and mutated gliomas in Edge median values using Prewitt filtering. The current study introduced two image metrics that reflect lesion texture described on T2WI. These two metrics were validated by readings of a neuro-radiologist who was blinded to the results. This observation will facilitate further use of this technique in future large scale image analysis of glioma.

  19. Dynamics of metamorphism processes by the fractal textures analysis of garnets, amphiboles and pyroxenes of Lapland Granulite Belt, Kola Peninsula

    Directory of Open Access Journals (Sweden)

    Miłosz A. Huber

    2012-01-01

    Full Text Available About thousand analyzes of garnet, amphibole and pyroxene crystals from selected samples of amphibolite and granulite rocks from Lapland Granulite Belt in Kandalaksha region (Kola Peninsula has been made. Indicated fractal-box dimension of studied minerals has a good correlation with tectonic zones, lead to a new insight in the dynamics of processes, which has modified the examined region. Fractal-box dimension makes the textural analysis more precise, because it consents for the mathematic and repeated review of crystals topology depending directly on processes which had created them.

  20. Texture analysis applied to second harmonic generation image data for disease classification and development of a multi-view second harmonic generation imaging platform

    Science.gov (United States)

    Wen, Lianggong

    Many diseases, e.g. ovarian cancer, breast cancer and pulmonary fibrosis, are commonly associated with drastic alterations in surrounding connective tissue, and changes in the extracellular matrix (ECM) are associated with the vast majority of cellular processes in disease progression and carcinogenesis: cell differentiation, proliferation, biosynthetic ability, polarity, and motility. We use second harmonic generation (SHG) microscopy for imaging the ECM because it is a non-invasive, non-linear laser scanning technique with high sensitivity and specificity for visualizing fibrillar collagen. In this thesis, we are interested in developing imaging techniques to understand how the ECM, especially the collagen architecture, is remodeled in diseases. To quantitate remodeling, we implement a 3D texture analysis to delineate the collagen fibrillar morphology observed in SHG microscopy images of human normal and high grade malignant ovarian tissues. In the learning stage, a dictionary of "textons"---frequently occurring texture features that are identified by measuring the image response to a filter bank of various shapes, sizes, and orientations---is created. By calculating a representative model based on the texton distribution for each tissue type using a training set of respective mages, we then perform classification between normal and high grade malignant ovarian tissues classification based on the area under receiver operating characteristic curves (true positives versus false positives). The local analysis algorithm is a more general method to probe rapidly changing fibrillar morphologies than global analyses such as FFT. It is also more versatile than other texture approaches as the filter bank can be highly tailored to specific applications (e.g., different disease states) by creating customized libraries based on common image features. Further, we describe the development of a multi-view 3D SHG imaging platform. Unlike fluorescence microscopy, SHG excites

  1. Analysis of physical properties of color and texture in goji-berry processed by ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Pâmela Galo da; Koike, Amanda Cristina Ramos; Villavicencio, Anna Lucia Casañas Haasis, E-mail: pamela.gallo@outlook.com, E-mail: amandaramosk@gmail.com, E-mail: villavic@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Rodrigues, Flavio Thihara, E-mail: flaviot@ymail.com [Instituto Federal de Educação, Ciência e Tecnologia de Goiás (IFG), Inhumas, GO (Brazil)

    2017-07-01

    Goji-berry is fruit native from China, found on a red berry form and keeps an excellent source of antioxidants, such as carotenoids. The consumption of goji-berry is growing on the Brazilian commerce. To allow the commercialization of this foods its necessary of these foods are free of contaminants agents which may cause damages to the consumers health. For this warranty it's required of this method does not harm the food properties and quality. For this check was made the study using goji-berry. Irradiation is one of the methods that improves the safety and extends the shelf life of some foods. Food irradiation is a technology process of exposing a particular food to a controlled dose of ionizing radiation. This study aimed compares the effects of ionizing radiation processing on physical properties of color and texture in goji-berries at different irradiation doses. Samples were bought on the retail market in the city of São Paulo and processed by ionizing radiation on Nuclear and Energy Research Institute (IPEN/CNEN-SP) at doses of 2.5; 5.0; 7.5; 10.0 kGy and the control group. Then the samples were followed by color and texture analyses. The color assay's results showed that the irradiation process decreased red and yellow pigments. On the other hand, the sample's luminosity increased after being processed by ionizing radiation. On the texture assay was verified a decrease of the fruit compressive force, turning the fruit more softened. (author)

  2. Analysis of physical properties of color and texture in goji-berry processed by ionizing radiation

    International Nuclear Information System (INIS)

    Silva, Pâmela Galo da; Koike, Amanda Cristina Ramos; Villavicencio, Anna Lucia Casañas Haasis; Rodrigues, Flavio Thihara

    2017-01-01

    Goji-berry is fruit native from China, found on a red berry form and keeps an excellent source of antioxidants, such as carotenoids. The consumption of goji-berry is growing on the Brazilian commerce. To allow the commercialization of this foods its necessary of these foods are free of contaminants agents which may cause damages to the consumers health. For this warranty it's required of this method does not harm the food properties and quality. For this check was made the study using goji-berry. Irradiation is one of the methods that improves the safety and extends the shelf life of some foods. Food irradiation is a technology process of exposing a particular food to a controlled dose of ionizing radiation. This study aimed compares the effects of ionizing radiation processing on physical properties of color and texture in goji-berries at different irradiation doses. Samples were bought on the retail market in the city of São Paulo and processed by ionizing radiation on Nuclear and Energy Research Institute (IPEN/CNEN-SP) at doses of 2.5; 5.0; 7.5; 10.0 kGy and the control group. Then the samples were followed by color and texture analyses. The color assay's results showed that the irradiation process decreased red and yellow pigments. On the other hand, the sample's luminosity increased after being processed by ionizing radiation. On the texture assay was verified a decrease of the fruit compressive force, turning the fruit more softened. (author)

  3. Characterization of Tumor Heterogeneity by Texture Analysis in 18F-FDG PET images: A Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Manso, M.; Martino, M.E.; Rodriguez, E.A.; Landaeta, L.C.; Carreras, J.L.; Calvo, F.A.; Desco, M.; Pascau, J.; Muñoz-Barrutia, M.

    2016-07-01

    2-Deoxy-2-[18F]-fluoro-D-glucose (FDG) positron emission tomography (PET) is often used in clinic for cancer diagnosis, staging, therapy planning and monitoring. Alternative features to the classical semi-quantitative variables have been recently proposed to study the heterogeneity of tumors. The method to extract such characteristics is texture analysis, which quantifies variations of uptake distribution within the lesions. Methods: Fifty-three head and neck and twelve rectal cancer patients were included in the analysis. A workflow in an open-source software, 3D slicer, was designed and expert clinicians were trained on its use, sixty six features were calculated including metabolic and texture parameters. Statistical analysis and dimensionality reduction techniques were performed on the data. Results: After observing a high correlation between variables, dimensions were reduced to five and three independent components for head and neck and rectal cancer cohort, respectively. Conclusion: Tumor heterogeneity parameters could be expressing important information about tumor and cancer disease, information that could be used to assess disease staging, patients’ prognosis, therapy plan and survival. (Author)

  4. Risk Analysis Group annual progress report 1984

    International Nuclear Information System (INIS)

    1985-06-01

    The activities of the Risk Analysis Group at Risoe during 1984 are presented. These include descriptions in some detail of work on general development topics and risk analysis performed as contractor. (author)

  5. Human versus artificial texture perception

    NARCIS (Netherlands)

    Petiet, Peter J.; van Erp, J.; Drullman, R.; van den Broek, Egon; Beintema, J.; van Wijngaarden, S.

    2006-01-01

    The performances of current texture analysis algorithms are still poor, especially when applied to a large, diffuse texture domain. Most of these purely computationally driven techniques are created to function within a highly restricted domain. When applied as computer vision techniques, frequently

  6. Preferred orientation of a naturally and experimentally deformed pyrrhotite ore by X-ray and neutron diffraction texture analysis

    International Nuclear Information System (INIS)

    Niederschlag, E.; Brokmeier, H.G.; Siemes, H.

    1994-01-01

    Two samples of polycrystalline naturally deformed hexagonal Pyrrhotite were deformed experimentally in axial compression tests with different temperatures and strain. The texture of the naturally deformed ore was investigated both by X-ray and neutron texture analyses. Texture measurements on the experimentally deformed ore were carried out by neutron diffraction. (orig.)

  7. Statistical analysis of textural features for improved classification of oral histopathological images.

    Science.gov (United States)

    Muthu Rama Krishnan, M; Shah, Pratik; Chakraborty, Chandan; Ray, Ajoy K

    2012-04-01

    The objective of this paper is to provide an improved technique, which can assist oncopathologists in correct screening of oral precancerous conditions specially oral submucous fibrosis (OSF) with significant accuracy on the basis of collagen fibres in the sub-epithelial connective tissue. The proposed scheme is composed of collagen fibres segmentation, its textural feature extraction and selection, screening perfomance enhancement under Gaussian transformation and finally classification. In this study, collagen fibres are segmented on R,G,B color channels using back-probagation neural network from 60 normal and 59 OSF histological images followed by histogram specification for reducing the stain intensity variation. Henceforth, textural features of collgen area are extracted using fractal approaches viz., differential box counting and brownian motion curve . Feature selection is done using Kullback-Leibler (KL) divergence criterion and the screening performance is evaluated based on various statistical tests to conform Gaussian nature. Here, the screening performance is enhanced under Gaussian transformation of the non-Gaussian features using hybrid distribution. Moreover, the routine screening is designed based on two statistical classifiers viz., Bayesian classification and support vector machines (SVM) to classify normal and OSF. It is observed that SVM with linear kernel function provides better classification accuracy (91.64%) as compared to Bayesian classifier. The addition of fractal features of collagen under Gaussian transformation improves Bayesian classifier's performance from 80.69% to 90.75%. Results are here studied and discussed.

  8. Hydride-induced degradation of hoop ductility in textured zirconium-alloy tubes: A theoretical analysis

    International Nuclear Information System (INIS)

    Qin, W.; Szpunar, J.A.; Kozinski, J.

    2012-01-01

    Hydride-induced degradation of hoop ductility in Zr-alloy tubular components has been studied for many years because of its importance in the nuclear industry. In this paper the role of intergranular and intragranular δ-hydrides in the degradation of ductility of the textured Zr-alloy tubes is investigated. The correlation among hydride distribution, orientation and morphology in the tubes is formulated based on thermodynamic modeling, and then analyzed. The results show that the applied stress, the crystallographic texture of α-Zr matrix, the grain-boundary structure, and the morphology and size of Zr grains simultaneously govern the site preference and the orientation of hydrides. A criterion is proposed to determine the threshold stress of hydride reorientation. The hoop ductility of the hydrided Zr tubes is discussed using the concept of macroscopic fracture strain. It is shown that the intergranular hydrides may be more deleterious to ductility than the intragranular ones. This work defines a general framework for understanding the relation of the microstructure of hydride-forming materials to embrittlement.

  9. Soil texture analysis revisited: Removal of organic matter matters more than ever

    Science.gov (United States)

    Schjønning, Per; Watts, Christopher W.; Christensen, Bent T.; Munkholm, Lars J.

    2017-01-01

    Exact estimates of soil clay (<2 μm) and silt (2–20 μm) contents are crucial as these size fractions impact key soil functions, and as pedotransfer concepts based on clay and silt contents are becoming increasingly abundant. We examined the effect of removing soil organic matter (SOM) by H2O2 before soil dispersion and determination of clay and silt. Soil samples with gradients in SOM were retrieved from three long-term field experiments each with uniform soil mineralogy and texture. For soils with less than 2 g C 100 g-1 minerals, clay estimates were little affected by SOM. Above this threshold, underestimation of clay increased dramatically with increasing SOM content. Silt contents were systematically overestimated when SOM was not removed; no lower SOM threshold was found for silt, but the overestimation was more pronounced for finer textured soils. When exact estimates of soil particles <20 μm are needed, SOM should always be removed before soil dispersion. PMID:28542416

  10. Texture Feature Analysis for Different Resolution Level of Kidney Ultrasound Images

    Science.gov (United States)

    Kairuddin, Wan Nur Hafsha Wan; Mahmud, Wan Mahani Hafizah Wan

    2017-08-01

    Image feature extraction is a technique to identify the characteristic of the image. The objective of this work is to discover the texture features that best describe a tissue characteristic of a healthy kidney from ultrasound (US) image. Three ultrasound machines that have different specifications are used in order to get a different quality (different resolution) of the image. Initially, the acquired images are pre-processed to de-noise the speckle to ensure the image preserve the pixels in a region of interest (ROI) for further extraction. Gaussian Low- pass Filter is chosen as the filtering method in this work. 150 of enhanced images then are segmented by creating a foreground and background of image where the mask is created to eliminate some unwanted intensity values. Statistical based texture features method is used namely Intensity Histogram (IH), Gray-Level Co-Occurance Matrix (GLCM) and Gray-level run-length matrix (GLRLM).This method is depends on the spatial distribution of intensity values or gray levels in the kidney region. By using One-Way ANOVA in SPSS, the result indicated that three features (Contrast, Difference Variance and Inverse Difference Moment Normalized) from GLCM are not statistically significant; this concludes that these three features describe a healthy kidney characteristics regardless of the ultrasound image quality.

  11. Second order statistical analysis of US image texture; Analisi della tessitura delle immagini ecografiche con metodi statistici del secondo ordine

    Energy Technology Data Exchange (ETDEWEB)

    Tanzi, F.; Novario, R. [Varese Ospedale di Circolo, Varese (Italy). Servizio di fisica sanitaria; Conte, L. [Varese Univ., Varese (Italy). Cattedra di biofisica e tecnologie biomediche; Tosetto, C.; Dimichele, R. [Milan Clinica Mangiagalli, Milan (Italy). Istituti clinici di perfezionamento; Goddi, A. [SME, Studio medico di diagnostica per immagini, Varese (Italy)

    1999-05-01

    The study reports the sonographic image texture of the neonatal heart in different stages of development by calculating numerical parameters extracted from the gray scale co-occurrence matrix. To show pixel values differences and enhance texture structure, images were equalized and then the gray level range was reduced to 16 to allow sufficiently high occupancy frequency of the co-occurrence matrix. Differences are so little significant that they may be due to different factors affecting image texture and the variability introduced by manual ROI positioning; therefore no definitive conclusions can be drawn as to considering this kind of analysis capable of discriminating different stages of myocardial development. [Italian] Scopo del lavoro e' la caratterizzazione della tessitura di immagini ecocardiografiche di neonati in diverse fasi dell'accrescimento mediante il valore di parametri ottenuti con il metodo della matrice delle co-occorrenze. Per evidenziare le differenze tra i pixel e quindi esaltare la tessitura, le immagini sono state elaborate mediante equalizzazione, successivamente sono state ridotte a 16 livelli di grigio al fine di avere alta frequenza di occupazione della matrice delle co-occorrenze. Nonostante alcuni confronti risultino significativi a livello del 95% dei casi, non si possono trarre conclusioni definitive circa la possibilita' di utilizzare questa metodica per disciminare fasi diverse della crescita miocardica, in quanto le differenze di tessitura sono cosi' lievi che possono essere ascrivibili alla normale variabilita' della tessitura introdotta dal metodo di acquisizione delle immagini e dal posizionamento delle regioni di interesse.

  12. Systems Analysis Department annual progress report 1998

    DEFF Research Database (Denmark)

    1999-01-01

    The report describes the work of the Systems Analysis Department at Risø National Laboratory during 1998. The department undertakes research within Energy Systems Analysis, Integrated Energy, Environment and Development Planning - UNEP Centre, IndustrialSafety and Reliability, Man/Machine Interac....../Machine Interaction, and Technology Scenarios. The report includes lists of publications, lectures, committees and staff members....

  13. Systems Analysis Department annual progress report 1999

    DEFF Research Database (Denmark)

    2000-01-01

    This report describes the work of the Systems Analysis Department at Risø National Laboratory during 1999. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning - UNEP Centre, Safety,Realiability and Human Factors, and Technology...

  14. Systems Analysis Department. Annual Progress Report 1999

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Hans; Olsson, Charlotte; Loevborg, Leif [eds.

    2000-03-01

    This report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1999. The department is undertaking research within Energy Systems Analysis, Energy, Environment and Development Planning-UNEP Centre, Safety, Reliability and Human Factors, and Technology Scenarios. The report includes summary statistics and lists of publications, committees and staff members. (au)

  15. Systems Analysis department. Annual progress report 1997

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Hans; Olsson, Charlotte; Petersen, Kurt E

    1998-03-01

    The report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1997. The department is undertaking research within Energy systems Analysis, Integrated Energy, Environment and Development Planning - UNEP Centre, Industrial Safety and Reliability and Man/Machine Interaction. The report includes lists of publications lectures, committees and staff members. (au) 110 refs.

  16. Systems Analysis Department annual progress report 1998

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Hans; Olsson, Charlotte; Loevborg, Leif [eds.

    1999-03-01

    The report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1998. The department undertakes research within Energy Systems Analysis, Integrated Energy, Environment and Development Planning - UNEP Centre, Industrial Safety and Reliability, Man/Machine Interaction and Technology Scenarios. The report includes lists of publications, lectures, committees and staff members. (au) 111 refs.

  17. Progress report on the AMT analysis

    International Nuclear Information System (INIS)

    Wood, B.

    1992-01-01

    ICF Resources Incorporated's analysis of the Alternative Minimum Tax (AMT) has examined its effect on the US oil and gas industry from several different perspectives, to estimate the effect of the three relief proposals and to better understand the source of the outcry about the AMTs ''inequities.'' This report is a brief summary of the methodology and results to date. The complexity of the accounting mechanisms that comprise the AMT and the disparity between this analytical conclusions and clauses made by the oil and gas industry (principally the IPAA) have led this analysis through several distinct phases of: Project-level analysis; firm-level analysis; and demographic analysis. These analyses are described in detail

  18. Texture analysis on the fluence map to evaluate the degree of modulation for volumetric modulated arc therapy

    International Nuclear Information System (INIS)

    Park, So-Yeon; Kim, Il Han; Ye, Sung-Joon; Carlson, Joel

    2014-01-01

    Purpose: Texture analysis on fluence maps was performed to evaluate the degree of modulation for volumetric modulated arc therapy (VMAT) plans. Methods: A total of six textural features including angular second moment, inverse difference moment, contrast, variance, correlation, and entropy were calculated for fluence maps generated from 20 prostate and 20 head and neck VMAT plans. For each of the textural features, particular displacement distances (d) of 1, 5, and 10 were adopted. To investigate the deliverability of each VMAT plan, gamma passing rates of pretreatment quality assurance, and differences in modulating parameters such as multileaf collimator (MLC) positions, gantry angles, and monitor units at each control point between VMAT plans and dynamic log files registered by the Linac control system during delivery were acquired. Furthermore, differences between the original VMAT plan and the plan reconstructed from the dynamic log files were also investigated. To test the performance of the textural features as indicators for the modulation degree of VMAT plans, Spearman’s rank correlation coefficients (r s ) with the plan deliverability were calculated. For comparison purposes, conventional modulation indices for VMAT including the modulation complexity score for VMAT, leaf travel modulation complexity score, and modulation index supporting station parameter optimized radiation therapy (MI SPORT ) were calculated, and their correlations were analyzed in the same way. Results: There was no particular textural feature which always showed superior correlations with every type of plan deliverability. Considering the results comprehensively, contrast (d = 1) and variance (d = 1) generally showed considerable correlations with every type of plan deliverability. These textural features always showed higher correlations to the plan deliverability than did the conventional modulation indices, except in the case of modulating parameter differences. The r s values

  19. Texture analysis on the fluence map to evaluate the degree of modulation for volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Park, So-Yeon [Department of Radiation Oncology, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 110-744 (Korea, Republic of); Biomedical Research Institute, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of); Kim, Il Han [Department of Radiation Oncology, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 110-744 (Korea, Republic of); Biomedical Research Institute, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Department of Radiation Oncology, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Ye, Sung-Joon [Department of Radiation Oncology, Seoul National University Hospital, Seoul 110-744, (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 110-744 (Korea, Republic of); Biomedical Research Institute, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Suwon 433-270 (Korea, Republic of); Carlson, Joel [Biomedical Research Institute, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Suwon 433-270 (Korea, Republic of); and others

    2014-11-01

    Purpose: Texture analysis on fluence maps was performed to evaluate the degree of modulation for volumetric modulated arc therapy (VMAT) plans. Methods: A total of six textural features including angular second moment, inverse difference moment, contrast, variance, correlation, and entropy were calculated for fluence maps generated from 20 prostate and 20 head and neck VMAT plans. For each of the textural features, particular displacement distances (d) of 1, 5, and 10 were adopted. To investigate the deliverability of each VMAT plan, gamma passing rates of pretreatment quality assurance, and differences in modulating parameters such as multileaf collimator (MLC) positions, gantry angles, and monitor units at each control point between VMAT plans and dynamic log files registered by the Linac control system during delivery were acquired. Furthermore, differences between the original VMAT plan and the plan reconstructed from the dynamic log files were also investigated. To test the performance of the textural features as indicators for the modulation degree of VMAT plans, Spearman’s rank correlation coefficients (r{sub s}) with the plan deliverability were calculated. For comparison purposes, conventional modulation indices for VMAT including the modulation complexity score for VMAT, leaf travel modulation complexity score, and modulation index supporting station parameter optimized radiation therapy (MI{sub SPORT}) were calculated, and their correlations were analyzed in the same way. Results: There was no particular textural feature which always showed superior correlations with every type of plan deliverability. Considering the results comprehensively, contrast (d = 1) and variance (d = 1) generally showed considerable correlations with every type of plan deliverability. These textural features always showed higher correlations to the plan deliverability than did the conventional modulation indices, except in the case of modulating parameter differences. The r

  20. Progress in spatial analysis methods and applications

    CERN Document Server

    Páez, Antonio; Buliung, Ron N; Dall'erba, Sandy

    2010-01-01

    This book brings together developments in spatial analysis techniques, including spatial statistics, econometrics, and spatial visualization, and applications to fields such as regional studies, transportation and land use, population and health.

  1. Low-order non-spatial effects dominate second-order spatial effects in the texture quantifier analysis of 18F-FDG-PET images.

    Directory of Open Access Journals (Sweden)

    Frank J Brooks

    Full Text Available There is increasing interest in applying image texture quantifiers to assess the intra-tumor heterogeneity observed in FDG-PET images of various cancers. Use of these quantifiers as prognostic indicators of disease outcome and/or treatment response has yielded inconsistent results. We study the general applicability of some well-established texture quantifiers to the image data unique to FDG-PET.We first created computer-simulated test images with statistical properties consistent with clinical image data for cancers of the uterine cervix. We specifically isolated second-order statistical effects from low-order effects and analyzed the resulting variation in common texture quantifiers in response to contrived image variations. We then analyzed the quantifiers computed for FIGOIIb cervical cancers via receiver operating characteristic (ROC curves and via contingency table analysis of detrended quantifier values.We found that image texture quantifiers depend strongly on low-effects such as tumor volume and SUV distribution. When low-order effects are controlled, the image texture quantifiers tested were not able to discern only the second-order effects. Furthermore, the results of clinical tumor heterogeneity studies might be tunable via choice of patient population analyzed.Some image texture quantifiers are strongly affected by factors distinct from the second-order effects researchers ostensibly seek to assess via those quantifiers.

  2. Analysis of the texture of zircaloy-4 sheet by crystallite orientation distribution function

    International Nuclear Information System (INIS)

    Ryoo, Hwei Soo; Hwang Sun Keum

    1990-01-01

    In order to analyze the texture variation of Zircaloy-4 sheet the Roe's method of calculating the crystallite orientation distribution function(CODF) for hcp system was computer programmed. The coefficients W lmn of CODF were calculated from plane-normal distribution pole figures obtained by X-ray diffraction, and the CODF was computed from a series expansion of spherical harmonics. The Legendre function, which is the basis of the harmonics, was computed up to l=16 to account for the symmetry systems of specimen and hcp crystal. A cross-rolling followed by beta-phase heat treatment and furnace cooling increased the density of basal poles along the sheet normal direction and rotated prism poles around the c axis. (Author)

  3. Analysis of texture in baby carrot (Daucus carota) subjected to the process of ionizing radiation

    International Nuclear Information System (INIS)

    Nunes, Thaise C.F.; Rogovschi, Vladimir D.; Fabbri, Adriana D.T.; Sagretti, Juliana M.A.; Sabato, Susy F.

    2011-01-01

    The carrot is a vegetable of great economic value due to its versatility in the food industry and can be used as raw or minimally processed vegetable or aggregating value to the product, transforming the fresh carrots in baby carrots. It is well known that the application of gamma radiation in food may help in maintaining the quality of food. The aim of this study was to analyze the effects of the low doses of ionizing radiation on texture of minimally processed baby carrot after the processing in a Multipurpose 60 Co irradiator. It can be concluded that the treatment with low doses of gamma radiation keep the quality of fresh-cut baby carrot. (author)

  4. Numerical analysis of the texture effect on the hydrodynamic performance of a mechanical seal

    Science.gov (United States)

    Adjemout, M.; Brunetiere, N.; Bouyer, J.

    2016-03-01

    The purpose of this paper is to analyze the effect of the main geometrical characteristics of texture on the hydrodynamic lubrication of a mechanical seal. A parametric study was carried out in order to improve the performance of a mechanical seal. The numerical model used in this study solves the Reynolds equation coupled with a mass conservative model which takes into account the cavitation phenomenon. It is shown that among the six dimple shapes tested herein, namely cylinder, square, triangle, truncated cone, truncated pyramid, and spherical cap, the triangular dimples placed symmetrically with respect to their bases are more effective for enhancing the hydrodynamic performance of the mechanical seal. The effect of the area and depth ratios is studied and optimized as well. The optimized solution is able to minimize friction and leakage under a range of operating conditions.

  5. SU-E-J-262: Variability in Texture Analysis of Gynecological Tumors in the Context of An 18F-FDG PET Adaptive Protocol

    International Nuclear Information System (INIS)

    Nawrocki, J; Chino, J; Das, S; Craciunescu, O

    2015-01-01

    Purpose: This study examines the effect on texture analysis due to variable reconstruction of PET images in the context of an adaptive FDG PET protocol for node positive gynecologic cancer patients. By measuring variability in texture features from baseline and intra-treatment PET-CT, we can isolate unreliable texture features due to large variation. Methods: A subset of seven patients with node positive gynecological cancers visible on PET was selected for this study. Prescribed dose varied between 45–50.4Gy, with a 55–70Gy boost to the PET positive nodes. A baseline and intratreatment (between 30–36Gy) PET-CT were obtained on a Siemens Biograph mCT. Each clinical PET image set was reconstructed 6 times using a TrueX+TOF algorithm with varying iterations and Gaussian filter. Baseline and intra-treatment primary GTVs were segmented using PET Edge (MIM Software Inc., Cleveland, OH), a semi-automatic gradient-based algorithm, on the clinical PET and transferred to the other reconstructed sets. Using an in-house MATLAB program, four 3D texture matrices describing relationships between voxel intensities in the GTV were generated: co-occurrence, run length, size zone, and neighborhood difference. From these, 39 textural features characterizing texture were calculated in addition to SUV histogram features. The percent variability among parameters was first calculated. Each reconstructed texture feature from baseline and intra-treatment per patient was normalized to the clinical baseline scan and compared using the Wilcoxon signed-rank test in order to isolate variations due to reconstruction parameters. Results: For the baseline scans, 13 texture features showed a mean range greater than 10%. For the intra scans, 28 texture features showed a mean range greater than 10%. Comparing baseline to intra scans, 25 texture features showed p <0.05. Conclusion: Variability due to different reconstruction parameters increased with treatment, however, the majority of texture

  6. SU-E-J-262: Variability in Texture Analysis of Gynecological Tumors in the Context of An 18F-FDG PET Adaptive Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Nawrocki, J [Duke University Medical Physics Graduate Program, Durham, NC (United States); Chino, J; Das, S; Craciunescu, O [Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: This study examines the effect on texture analysis due to variable reconstruction of PET images in the context of an adaptive FDG PET protocol for node positive gynecologic cancer patients. By measuring variability in texture features from baseline and intra-treatment PET-CT, we can isolate unreliable texture features due to large variation. Methods: A subset of seven patients with node positive gynecological cancers visible on PET was selected for this study. Prescribed dose varied between 45–50.4Gy, with a 55–70Gy boost to the PET positive nodes. A baseline and intratreatment (between 30–36Gy) PET-CT were obtained on a Siemens Biograph mCT. Each clinical PET image set was reconstructed 6 times using a TrueX+TOF algorithm with varying iterations and Gaussian filter. Baseline and intra-treatment primary GTVs were segmented using PET Edge (MIM Software Inc., Cleveland, OH), a semi-automatic gradient-based algorithm, on the clinical PET and transferred to the other reconstructed sets. Using an in-house MATLAB program, four 3D texture matrices describing relationships between voxel intensities in the GTV were generated: co-occurrence, run length, size zone, and neighborhood difference. From these, 39 textural features characterizing texture were calculated in addition to SUV histogram features. The percent variability among parameters was first calculated. Each reconstructed texture feature from baseline and intra-treatment per patient was normalized to the clinical baseline scan and compared using the Wilcoxon signed-rank test in order to isolate variations due to reconstruction parameters. Results: For the baseline scans, 13 texture features showed a mean range greater than 10%. For the intra scans, 28 texture features showed a mean range greater than 10%. Comparing baseline to intra scans, 25 texture features showed p <0.05. Conclusion: Variability due to different reconstruction parameters increased with treatment, however, the majority of texture

  7. Bas-relief map using texture analysis with application to live enhancement of ultrasound images.

    Science.gov (United States)

    Du, Huarui; Ma, Rui; Wang, Xiaoying; Zhang, Jue; Fang, Jing

    2015-05-01

    For ultrasound imaging, speckle is one of the most important factors in the degradation of contrast resolution because it masks meaningful texture and has the potential to interfere with diagnosis. It is expected that researchers would explore appropriate ways to reduce the speckle noise, to find the edges of structures and enhance weak borders between different organs in ultrasound imaging. Inspired by the principle of differential interference contrast microscopy, a "bas-relief map" is proposed that depicts the texture structure of ultrasound images. Based on a bas-relief map, an adaptive bas-relief filter was developed for ultrafast despeckling. Subsequently, an edge map was introduced to enhance the edges of images in real time. The holistic bas-relief map approach has been used experimentally with synthetic phantoms and digital ultrasound B-scan images of liver, kidney and gallbladder. Based on the visual inspection and the performance metrics of the despeckled images, it was found that the bas-relief map approach is capable of effectively reducing the speckle while significantly enhancing contrast and tissue boundaries for ultrasonic images, and its speckle reduction ability is comparable to that of Kuan, Lee and Frost filters. Meanwhile, the proposed technique could preserve more intra-region details compared with the popular speckle reducing anisotropic diffusion technique and more effectively enhance edges. In addition, the adaptive bas-relief filter was much less time consuming than the Kuan, Lee and Frost filter and speckle reducing anisotropic diffusion techniques. The bas-relief map strategy is effective for speckle reduction and live enhancement of ultrasound images, and can provide a valuable tool for clinical diagnosis. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Comparison of demons deformable registration-based methods for texture analysis of serial thoracic CT scans

    Science.gov (United States)

    Cunliffe, Alexandra R.; Al-Hallaq, Hania A.; Fei, Xianhan M.; Tuohy, Rachel E.; Armato, Samuel G.

    2013-02-01

    To determine how 19 image texture features may be altered by three image registration methods, "normal" baseline and follow-up computed tomography (CT) scans from 27 patients were analyzed. Nineteen texture feature values were calculated in over 1,000 32x32-pixel regions of interest (ROIs) randomly placed in each baseline scan. All three methods used demons registration to map baseline scan ROIs to anatomically matched locations in the corresponding transformed follow-up scan. For the first method, the follow-up scan transformation was subsampled to achieve a voxel size identical to that of the baseline scan. For the second method, the follow-up scan was transformed through affine registration to achieve global alignment with the baseline scan. For the third method, the follow-up scan was directly deformed to the baseline scan using demons deformable registration. Feature values in matched ROIs were compared using Bland- Altman 95% limits of agreement. For each feature, the range spanned by the 95% limits was normalized to the mean feature value to obtain the normalized range of agreement, nRoA. Wilcoxon signed-rank tests were used to compare nRoA values across features for the three methods. Significance for individual tests was adjusted using the Bonferroni method. nRoA was significantly smaller for affine-registered scans than for the resampled scans (p=0.003), indicating lower feature value variability between baseline and follow-up scan ROIs using this method. For both of these methods, however, nRoA was significantly higher than when feature values were calculated directly on demons-deformed followup scans (p<0.001). Across features and methods, nRoA values remained below 26%.

  9. Machine learning-based quantitative texture analysis of CT images of small renal masses: Differentiation of angiomyolipoma without visible fat from renal cell carcinoma.

    Science.gov (United States)

    Feng, Zhichao; Rong, Pengfei; Cao, Peng; Zhou, Qingyu; Zhu, Wenwei; Yan, Zhimin; Liu, Qianyun; Wang, Wei

    2018-04-01

    To evaluate the diagnostic performance of machine-learning based quantitative texture analysis of CT images to differentiate small (≤ 4 cm) angiomyolipoma without visible fat (AMLwvf) from renal cell carcinoma (RCC). This single-institutional retrospective study included 58 patients with pathologically proven small renal mass (17 in AMLwvf and 41 in RCC groups). Texture features were extracted from the largest possible tumorous regions of interest (ROIs) by manual segmentation in preoperative three-phase CT images. Interobserver reliability and the Mann-Whitney U test were applied to select features preliminarily. Then support vector machine with recursive feature elimination (SVM-RFE) and synthetic minority oversampling technique (SMOTE) were adopted to establish discriminative classifiers, and the performance of classifiers was assessed. Of the 42 extracted features, 16 candidate features showed significant intergroup differences (P Machine learning analysis of CT texture features can facilitate the accurate differentiation of small AMLwvf from RCC. • Although conventional CT is useful for diagnosis of SRMs, it has limitations. • Machine-learning based CT texture analysis facilitate differentiation of small AMLwvf from RCC. • The highest accuracy of SVM-RFE+SMOTE classifier reached 93.9 %. • Texture analysis combined with machine-learning methods might spare unnecessary surgery for AMLwvf.

  10. Texture collapse

    International Nuclear Information System (INIS)

    Prokopec, T.; Sornborger, A.; Brandenberger, R.H.

    1992-01-01

    We study single-texture collapse using a leapfrog discretization method on a 30x30x30 spatial lattice. We investigate the influence of boundary conditions, physical size of the lattice, type of space-time background (flat, i.e., nonexpanding, vs radiation-dominated and matter-dominated universes), and spatial distribution of the initial texture configuration on collapse time and critical winding. For a spherically symmetric initial configuration of size equal to the horizon size on a lattice containing 12 (30) horizon volumes, the critical winding is found to be 0.621±0.001 (0.602±0.003) (flat case), 0.624±0.002 (0.604±0.005) (radiation era), 0.628±0.002 (0.612±0.003) (matter era). The larger the physical size of the lattice (in units of the horizon size), the smaller is the critical winding, and in the limit of an infinite lattice, we argue that the critical winding approaches 0.5. For radially asymmetric cases, contraction of one axis ( /Ipancake case) slightly reduces collapse time and critical winding, and contraction of two axes (d/Icigar case) reduces collapse time and critical winding significantly

  11. Quantitative Analysis of Patellar Tendon Abnormality in Asymptomatic Professional “Pallapugno” Players: A Texture-Based Ultrasound Approach

    Directory of Open Access Journals (Sweden)

    Kristen M. Meiburger

    2018-04-01

    Full Text Available Abnormalities in B-mode ultrasound images of the patellar tendon often take place in asymptomatic athletes but it is still not clear if these modifications forego or can predict the development of tendinopathy. Subclinical tendinopathy can be arbitrarily defined as either (1 the presence of light structural changes in B-mode ultrasound images in association with mild neovascularization (determined with Power Doppler images or (2 the presence of moderate/severe structural changes with or without neovascularization. Up to now, the structural changes and neovascularization of the tendon are evaluated qualitatively by visual inspection of ultrasound images. The aim of this study is to investigate the capability of a quantitative texture-based approach to determine tendon abnormality of “pallapugno” players. B-mode ultrasound images of the patellar tendon were acquired in 14 players and quantitative texture parameters were calculated within a Region of Interest (ROI of both the non-dominant and the dominant tendon. A total of 90 features were calculated for each ROI, including 6 first-order descriptors, 24 Haralick features, and 60 higher-order spectra and entropy features. These features on the dominant and non-dominant side were used to perform a multivariate linear regression analysis (MANOVA and our results show that the descriptors can be effectively used to determine tendon abnormality and, more importantly, the occurrence of subclinical tendinopathy.

  12. Multi-Parametric MRI and Texture Analysis to Visualize Spatial Histologic Heterogeneity and Tumor Extent in Glioblastoma.

    Science.gov (United States)

    Hu, Leland S; Ning, Shuluo; Eschbacher, Jennifer M; Gaw, Nathan; Dueck, Amylou C; Smith, Kris A; Nakaji, Peter; Plasencia, Jonathan; Ranjbar, Sara; Price, Stephen J; Tran, Nhan; Loftus, Joseph; Jenkins, Robert; O'Neill, Brian P; Elmquist, William; Baxter, Leslie C; Gao, Fei; Frakes, David; Karis, John P; Zwart, Christine; Swanson, Kristin R; Sarkaria, Jann; Wu, Teresa; Mitchell, J Ross; Li, Jing

    2015-01-01

    Genetic profiling represents the future of neuro-oncology but suffers from inadequate biopsies in heterogeneous tumors like Glioblastoma (GBM). Contrast-enhanced MRI (CE-MRI) targets enhancing core (ENH) but yields adequate tumor in only ~60% of cases. Further, CE-MRI poorly localizes infiltrative tumor within surrounding non-enhancing parenchyma, or brain-around-tumor (BAT), despite the importance of characterizing this tumor segment, which universally recurs. In this study, we use multiple texture analysis and machine learning (ML) algorithms to analyze multi-parametric MRI, and produce new images indicating tumor-rich targets in GBM. We recruited primary GBM patients undergoing image-guided biopsies and acquired pre-operative MRI: CE-MRI, Dynamic-Susceptibility-weighted-Contrast-enhanced-MRI, and Diffusion Tensor Imaging. Following image coregistration and region of interest placement at biopsy locations, we compared MRI metrics and regional texture with histologic diagnoses of high- vs low-tumor content (≥80% vs heterogeneity to identify regional tumor-rich biopsy targets.

  13. Systems Analysis Department. Annual progress report 1996

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, H; Olsson, C; Petersen, K E [eds.

    1997-03-01

    The report describes the work of the Systems Analysis Department at Risoe National Laboratory during 1996. The department is undertaking research within Simulation and Optimisation of Energy Systems, Energy and Environment in Developing Countries - UNEP Centre, Integrated Environmental and Risk Management and Man/Machine Interaction. The report includes lists of publications, lectures, committees and staff members. (au) 131 refs.

  14. A primary study on texture modification and proteolysis of mao-tofu ...

    African Journals Online (AJOL)

    Proteolysis occurred during fermentation was evaluated by SDS-PAGE and chemical analysis. Results from Texture Profile Analysis showed that adhesiveness of mao-tofu had an increase trend while hardness, cohesiveness and springiness had a decrease trend as fermentation progressed. SEM analysis showed that the ...

  15. Dynamics and vibrations progress in nonlinear analysis

    CERN Document Server

    Kachapi, Seyed Habibollah Hashemi

    2014-01-01

    Dynamical and vibratory systems are basically an application of mathematics and applied sciences to the solution of real world problems. Before being able to solve real world problems, it is necessary to carefully study dynamical and vibratory systems and solve all available problems in case of linear and nonlinear equations using analytical and numerical methods. It is of great importance to study nonlinearity in dynamics and vibration; because almost all applied processes act nonlinearly, and on the other hand, nonlinear analysis of complex systems is one of the most important and complicated tasks, especially in engineering and applied sciences problems. There are probably a handful of books on nonlinear dynamics and vibrations analysis. Some of these books are written at a fundamental level that may not meet ambitious engineering program requirements. Others are specialized in certain fields of oscillatory systems, including modeling and simulations. In this book, we attempt to strike a balance between th...

  16. Radiation injury vs. recurrent brain metastasis: combining textural feature radiomics analysis and standard parameters may increase {sup 18}F-FET PET accuracy without dynamic scans

    Energy Technology Data Exchange (ETDEWEB)

    Lohmann, Philipp; Stoffels, Gabriele; Stegmayr, Carina; Neumaier, Bernd [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); Ceccon, Garry [University of Cologne, Department of Neurology, Cologne (Germany); Rapp, Marion; Sabel, Michael; Kamp, Marcel A. [Heinrich Heine University Duesseldorf, Department of Neurosurgery, Duesseldorf (Germany); Filss, Christian P. [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany); Shah, Nadim J. [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); RWTH Aachen University Hospital, Department of Neurology, Aachen (Germany); Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain, Department of Neurology, Juelich (Germany); Langen, Karl-Josef [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany); Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain, Department of Neurology, Juelich (Germany); Galldiks, Norbert [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); University of Cologne, Department of Neurology, Cologne (Germany); University of Cologne, Center of Integrated Oncology (CIO), Cologne (Germany)

    2017-07-15

    We investigated the potential of textural feature analysis of O-(2-[{sup 18}F]fluoroethyl)-L-tyrosine ({sup 18}F-FET) PET to differentiate radiation injury from brain metastasis recurrence. Forty-seven patients with contrast-enhancing brain lesions (n = 54) on MRI after radiotherapy of brain metastases underwent dynamic {sup 18}F-FET PET. Tumour-to-brain ratios (TBRs) of {sup 18}F-FET uptake and 62 textural parameters were determined on summed images 20-40 min post-injection. Tracer uptake kinetics, i.e., time-to-peak (TTP) and patterns of time-activity curves (TAC) were evaluated on dynamic PET data from 0-50 min post-injection. Diagnostic accuracy of investigated parameters and combinations thereof to discriminate between brain metastasis recurrence and radiation injury was compared. Diagnostic accuracy increased from 81 % for TBR{sub mean} alone to 85 % when combined with the textural parameter Coarseness or Short-zone emphasis. The accuracy of TBR{sub max} alone was 83 % and increased to 85 % after combination with the textural parameters Coarseness, Short-zone emphasis, or Correlation. Analysis of TACs resulted in an accuracy of 70 % for kinetic pattern alone and increased to 83 % when combined with TBR{sub max}. Textural feature analysis in combination with TBRs may have the potential to increase diagnostic accuracy for discrimination between brain metastasis recurrence and radiation injury, without the need for dynamic {sup 18}F-FET PET scans. (orig.)

  17. CT-based texture analysis potentially provides prognostic information complementary to interim fdg-pet for patients with hodgkin's and aggressive non-hodgkin's lymphomas

    International Nuclear Information System (INIS)

    Ganeshan, B.; Miles, K.A.; Shortman, R.; Afaq, A.; Ardeshna, K.M.; Groves, A.M.; Kayani, I.; Babikir, S.

    2017-01-01

    The purpose of this study was to investigate the ability of computed tomography texture analysis (CTTA) to provide additional prognostic information in patients with Hodgkin's lymphoma (HL) and high-grade non-Hodgkin's lymphoma (NHL). This retrospective, pilot-study approved by the IRB comprised 45 lymphoma patients undergoing routine 18F-FDG-PET-CT. Progression-free survival (PFS) was determined from clinical follow-up (mean-duration: 40 months; range: 10-62 months). Non-contrast-enhanced low-dose CT images were submitted to CTTA comprising image filtration to highlight features of different sizes followed by histogram-analysis using kurtosis. Prognostic value of CTTA was compared to PET FDG-uptake value, tumour-stage, tumour-bulk, lymphoma-type, treatment-regime, and interim FDG-PET (iPET) status using Kaplan-Meier analysis. Cox regression analysis determined the independence of significantly prognostic imaging and clinical features. A total of 27 patients had aggressive NHL and 18 had HL. Mean PFS was 48.5 months. There was no significant difference in pre-treatment CTTA between the lymphoma sub-types. Kaplan-Meier analysis found pre-treatment CTTA (medium feature scale, p=0.010) and iPET status (p<0.001) to be significant predictors of PFS. Cox analysis revealed that an interaction between pre-treatment CTTA and iPET status was the only independent predictor of PFS (HR: 25.5, 95% CI: 5.4-120, p<0.001). Specifically, pre-treatment CTTA risk stratified patients with negative iPET. CTTA can potentially provide prognostic information complementary to iPET for patients with HL and aggressive NHL. (orig.)

  18. Dust emission parameterization scheme over the MENA region: Sensitivity analysis to soil moisture and soil texture

    Science.gov (United States)

    Gherboudj, Imen; Beegum, S. Naseema; Marticorena, Beatrice; Ghedira, Hosni

    2015-10-01

    The mineral dust emissions from arid/semiarid soils were simulated over the MENA (Middle East and North Africa) region using the dust parameterization scheme proposed by Alfaro and Gomes (2001), to quantify the effect of the soil moisture and clay fraction in the emissions. For this purpose, an extensive data set of Soil Moisture and Ocean Salinity soil moisture, European Centre for Medium-Range Weather Forecasting wind speed at 10 m height, Food Agricultural Organization soil texture maps, MODIS (Moderate Resolution Imaging Spectroradiometer) Normalized Difference Vegetation Index, and erodibility of the soil surface were collected for the a period of 3 years, from 2010 to 2013. Though the considered data sets have different temporal and spatial resolution, efforts have been made to make them consistent in time and space. At first, the simulated sandblasting flux over the region were validated qualitatively using MODIS Deep Blue aerosol optical depth and EUMETSAT MSG (Meteosat Seciond Generation) dust product from SEVIRI (Meteosat Spinning Enhanced Visible and Infrared Imager) and quantitatively based on the available ground-based measurements of near-surface particulate mass concentrations (PM10) collected over four stations in the MENA region. Sensitivity analyses were performed to investigate the effect of soil moisture and clay fraction on the emissions flux. The results showed that soil moisture and soil texture have significant roles in the dust emissions over the MENA region, particularly over the Arabian Peninsula. An inversely proportional dependency is observed between the soil moisture and the sandblasting flux, where a steep reduction in flux is observed at low friction velocity and a gradual reduction is observed at high friction velocity. Conversely, a directly proportional dependency is observed between the soil clay fraction and the sandblasting flux where a steep increase in flux is observed at low friction velocity and a gradual increase is

  19. TU-F-18C-09: Mammogram Surveillance Using Texture Analysis for Breast Cancer Patients After Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kuo, H; Tome, W; FOX, J; Hong, L; Yaparpalvi, R; Mehta, K; Bodner, W; Kalnicki, S [Montefiore Medical Center/Albert Einstein College of Medicine, Bronx, New York (United States); Huang, Y [Memorial Sloan-Kettering Cancer Center, Great Neck, NY (United States)

    2014-06-15

    Purpose: To study the feasibility of applying cancer risk model established from treated patients to predict the risk of recurrence on follow-up mammography after radiation therapy for both ipsilateral and contralateral breast. Methods: An extensive set of textural feature functions was applied to a set of 196 Mammograms from 50 patients. 56 Mammograms from 28 patients were used as training set, 44 mammograms from 22 patients were used as test set and the rest were used for prediction. Feature functions include Histogram, Gradient, Co-Occurrence Matrix, Run-Length Matrix and Wavelet Energy. An optimum subset of the feature functions was selected by Fisher Coefficient (FO) or Mutual Information (MI) (up to top 10 features) or a method combined FO, MI and Principal Component (FMP) (up to top 30 features). One-Nearest Neighbor (1-NN), Linear Discriminant Analysis (LDA) and Nonlinear Discriminant Analysis (NDA) were utilized to build a risk model of breast cancer from the training set of mammograms at the time of diagnosis. The risk model was then used to predict the risk of recurrence from mammogram taken one year and three years after RT. Results: FPM with NDA has the best classification power in classifying the training set of the mammogram with lesions versus those without lesions. The model of FPM with NDA achieved a true positive (TP) rate of 82% compared to 45.5% of using FO with 1-NN. The best false positive (FP) rates were 0% and 3.6% in contra-lateral breast of 1-year and 3-years after RT, and 10.9% in ipsi-lateral breast of 3-years after RT. Conclusion: Texture analysis offers high dimension to differentiate breast tissue in mammogram. Using NDA to classify mammogram with lesion from mammogram without lesion, it can achieve rather high TP and low FP in the surveillance of mammogram for patient with conservative surgery combined RT.

  20. Detection of architectural distortion in prior screening mammograms using Gabor filters, phase portraits, fractal dimension, and texture analysis

    International Nuclear Information System (INIS)

    Rangayyan, Rangaraj M.; Prajna, Shormistha; Ayres, Fabio J.; Desautels, J.E.L.

    2008-01-01

    Mammography is a widely used screening tool for the early detection of breast cancer. One of the commonly missed signs of breast cancer is architectural distortion. The purpose of this study is to explore the application of fractal analysis and texture measures for the detection of architectural distortion in screening mammograms taken prior to the detection of breast cancer. A method based on Gabor filters and phase portrait analysis was used to detect initial candidates for sites of architectural distortion. A total of 386 regions of interest (ROIs) were automatically obtained from 14 ''prior mammograms'', including 21 ROIs related to architectural distortion. From the corresponding set of 14 ''detection mammograms'', 398 ROIs were obtained, including 18 related to breast cancer. For each ROI, the fractal dimension and Haralick's texture features were computed. The fractal dimension of the ROIs was calculated using the circular average power spectrum technique. The average fractal dimension of the normal (false-positive) ROIs was significantly higher than that of the ROIs with architectural distortion (p = 0.006). For the ''prior mammograms'', the best receiver operating characteristics (ROC) performance achieved, in terms of the area under the ROC curve, was 0.80 with a Bayesian classifier using four features including fractal dimension, entropy, sum entropy, and inverse difference moment. Analysis of the performance of the methods with free-response receiver operating characteristics indicated a sensitivity of 0.79 at 8.4 false positives per image in the detection of sites of architectural distortion in the ''prior mammograms''. Fractal dimension offers a promising way to detect the presence of architectural distortion in prior mammograms. (orig.)

  1. Template characterization and correlation algorithm created from segmentation for the iris biometric authentication based on analysis of textures implemented on a FPGA

    International Nuclear Information System (INIS)

    Giacometto, F J; Vilardy, J M; Torres, C O; Mattos, L

    2011-01-01

    Among the most used biometric signals to set personal security permissions, taker increasingly importance biometric iris recognition based on their textures and images of blood vessels due to the rich in these two unique characteristics that are unique to each individual. This paper presents an implementation of an algorithm characterization and correlation of templates created for biometric authentication based on iris texture analysis programmed on a FPGA (Field Programmable Gate Array), authentication is based on processes like characterization methods based on frequency analysis of the sample, and frequency correlation to obtain the expected results of authentication.

  2. Organic analysis progress report FY 1997

    Energy Technology Data Exchange (ETDEWEB)

    Clauss, S.A.; Grant, K.E.; Hoopes, V.; Mong, G.M.; Steele, R.; Bellofatto, D.; Sharma, A.

    1998-04-01

    The Organic Analysis and Methods Development Task is being conducted by Pacific Northwest National Laboratory (PNNL) as part of the Organic Tank Waste Safety Project. The objective of the task is to apply developed analytical methods to identify and/or quantify the amount of particular organic species in tank wastes. In addition, this task provides analytical support for the Gas Generation Studies Task, Waste Aging, and Solubility Studies. This report presents the results from analyses of tank waste samples archived at Pacific Northwest National Laboratory (PNNL) and received from the Project Hanford Management Contractor (PHMC), which included samples associated with both the Flammable Gas and Organic Tank Waste Safety Programs. The data are discussed in Section 2.0. In addition, the results of analytical support for analyzing (1) simulated wastes for Waste Aging, (2) tank waste samples for Gas Generation, and (3) simulated wastes associated with solubility studies discussed in Sections 3.0, 4.0, and 5.0, respectively. The latter part of FY 1997 was devoted to documenting the analytical procedures, including derivation gas chromatography/mass spectrometry (GC/MS) and GC/FID for quantitation, ion-pair chromatography (IPC), IC, and the cation exchange procedure for reducing the radioactivity of samples. The documentation of analytical procedures is included here and discussed in Section 6.0 and Section 7.0 discusses other analytical procedures. The references are listed in Section 8.0 and future plans are discussed in Section 9.0. Appendix A is a preprint of a manuscript accepted for publication. Appendix B contains the cc mail messages and chain-of-custody forms for the samples received for analyses. Appendix C contains the test plan for analysis of tank waste samples.

  3. Organic analysis progress report FY 1997

    International Nuclear Information System (INIS)

    Clauss, S.A.; Grant, K.E.; Hoopes, V.; Mong, G.M.; Steele, R.; Bellofatto, D.; Sharma, A.

    1998-04-01

    The Organic Analysis and Methods Development Task is being conducted by Pacific Northwest National Laboratory (PNNL) as part of the Organic Tank Waste Safety Project. The objective of the task is to apply developed analytical methods to identify and/or quantify the amount of particular organic species in tank wastes. In addition, this task provides analytical support for the Gas Generation Studies Task, Waste Aging, and Solubility Studies. This report presents the results from analyses of tank waste samples archived at Pacific Northwest National Laboratory (PNNL) and received from the Project Hanford Management Contractor (PHMC), which included samples associated with both the Flammable Gas and Organic Tank Waste Safety Programs. The data are discussed in Section 2.0. In addition, the results of analytical support for analyzing (1) simulated wastes for Waste Aging, (2) tank waste samples for Gas Generation, and (3) simulated wastes associated with solubility studies discussed in Sections 3.0, 4.0, and 5.0, respectively. The latter part of FY 1997 was devoted to documenting the analytical procedures, including derivation gas chromatography/mass spectrometry (GC/MS) and GC/FID for quantitation, ion-pair chromatography (IPC), IC, and the cation exchange procedure for reducing the radioactivity of samples. The documentation of analytical procedures is included here and discussed in Section 6.0 and Section 7.0 discusses other analytical procedures. The references are listed in Section 8.0 and future plans are discussed in Section 9.0. Appendix A is a preprint of a manuscript accepted for publication. Appendix B contains the cc mail messages and chain-of-custody forms for the samples received for analyses. Appendix C contains the test plan for analysis of tank waste samples

  4. Classification of grass pollen through the quantitative analysis of surface ornamentation and texture.

    Science.gov (United States)

    Mander, Luke; Li, Mao; Mio, Washington; Fowlkes, Charless C; Punyasena, Surangi W

    2013-11-07

    Taxonomic identification of pollen and spores uses inherently qualitative descriptions of morphology. Consequently, identifications are restricted to categories that can be reliably classified by multiple analysts, resulting in the coarse taxonomic resolution of the pollen and spore record. Grass pollen represents an archetypal example; it is not routinely identified below family level. To address this issue, we developed quantitative morphometric methods to characterize surface ornamentation and classify grass pollen grains. This produces a means of quantifying morphological features that are traditionally described qualitatively. We used scanning electron microscopy to image 240 specimens of pollen from 12 species within the grass family (Poaceae). We classified these species by developing algorithmic features that quantify the size and density of sculptural elements on the pollen surface, and measure the complexity of the ornamentation they form. These features yielded a classification accuracy of 77.5%. In comparison, a texture descriptor based on modelling the statistical distribution of brightness values in image patches yielded a classification accuracy of 85.8%, and seven human subjects achieved accuracies between 68.33 and 81.67%. The algorithmic features we developed directly relate to biologically meaningful features of grass pollen morphology, and could facilitate direct interpretation of unsupervised classification results from fossil material.

  5. Observation and analysis of nanodomain textures in dielectric relaxor lead magnesium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Bursill, L A; Qian, Hua; Peng, Julin; Fan, X D

    1995-10-01

    High-resolution (0.2nm) images are used to locate chemical domains occurring with length scales of 1-5nm in the dielectric relaxor lead magnesium niobate (PMN). The experimental HRTEM images are analysed using computer-simulations and image matching in order to clarify and characterize the nature of the chemical ordering. Madelung electrostatic energy calculations are used to rank a set of structural models for possible ordered and disordered distributions of Nb and Mg over the B-sites of perovskite ABO{sub 3}. Next, the chemical domain textures are modelled using next-nearest-neighbour Ising (NNNI) models and Monte Carlo methods. This results in a preferred model for the B-site distribution (the extended NNN-Ising model), which is used for image simulations. Both HRTEM many-beam bright-and dark-field and single-beam dark-field TEM images are obtained and compared with the experimental images. The final result is a realistic atomic model for the Nb, Mg distribution of PMN. 42 refs., 2 tabs., 10 figs.

  6. Observation and analysis of nanodomain textures in dielectric relaxor lead magnesium niobate

    International Nuclear Information System (INIS)

    Bursill, L.A.; Qian, Hua; Peng, Julin; Fan, X.D.

    1995-01-01

    High-resolution (0.2nm) images are used to locate chemical domains occurring with length scales of 1-5nm in the dielectric relaxor lead magnesium niobate (PMN). The experimental HRTEM images are analysed using computer-simulations and image matching in order to clarify and characterize the nature of the chemical ordering. Madelung electrostatic energy calculations are used to rank a set of structural models for possible ordered and disordered distributions of Nb and Mg over the B-sites of perovskite ABO 3 . Next, the chemical domain textures are modelled using next-nearest-neighbour Ising (NNNI) models and Monte Carlo methods. This results in a preferred model for the B-site distribution (the extended NNN-Ising model), which is used for image simulations. Both HRTEM many-beam bright-and dark-field and single-beam dark-field TEM images are obtained and compared with the experimental images. The final result is a realistic atomic model for the Nb, Mg distribution of PMN. 42 refs., 2 tabs., 10 figs

  7. Instrumental texture profile analysis of gelatin gel extracted from grouper skin and commercial (bovine and porcine) gelatin gels.

    Science.gov (United States)

    Rahman, Mohammad Shafiur; Al-Mahrouqi, Abdullah Issa

    2009-01-01

    Mechanical compression was used to study the gelling characteristics of gelatin gels. Texture profile analysis (TPA) showed that the hardness of fish and mammalian gelatin increased significantly as the concentrations of gels increased. TPA attributes of 10% fish skin gel showed significant differences from those obtained from 20% and 30% gels. In bovine and porcine cases, such generic trends were not observed. Mechanical characteristics of 10% gels of gelatin from fish skin, determined from one cycle compression, were significantly lower than other sources of gelatin gels, while bovine and porcine gels did not show any significant differences. In the case of TPA, hardness of bovine gelatin gel was highest at 41 N for 10% gel, followed by porcine (30 N) then fish skin (5 N) gelatin gels. The gels prepared from different sources did not show any generic trends when all other mechanical attributes were considered.

  8. Statistical-techniques-based computer-aided diagnosis (CAD) using texture feature analysis: application in computed tomography (CT) imaging to fatty liver disease

    International Nuclear Information System (INIS)

    Chung, Woon-Kwan; Park, Hyong-Hu; Im, In-Chul; Lee, Jae-Seung; Goo, Eun-Hoe; Dong, Kyung-Rae

    2012-01-01

    This paper proposes a computer-aided diagnosis (CAD) system based on texture feature analysis and statistical wavelet transformation technology to diagnose fatty liver disease with computed tomography (CT) imaging. In the target image, a wavelet transformation was performed for each lesion area to set the region of analysis (ROA, window size: 50 x 50 pixels) and define the texture feature of a pixel. Based on the extracted texture feature values, six parameters (average gray level, average contrast, relative smoothness, skewness, uniformity, and entropy) were determined to calculate the recognition rate for a fatty liver. In addition, a multivariate analysis of the variance (MANOVA) method was used to perform a discriminant analysis to verify the significance of the extracted texture feature values and the recognition rate for a fatty liver. According to the results, each texture feature value was significant for a comparison of the recognition rate for a fatty liver (p < 0.05). Furthermore, the F-value, which was used as a scale for the difference in recognition rates, was highest in the average gray level, relatively high in the skewness and the entropy, and relatively low in the uniformity, the relative smoothness and the average contrast. The recognition rate for a fatty liver had the same scale as that for the F-value, showing 100% (average gray level) at the maximum and 80% (average contrast) at the minimum. Therefore, the recognition rate is believed to be a useful clinical value for the automatic detection and computer-aided diagnosis (CAD) using the texture feature value. Nevertheless, further study on various diseases and singular diseases will be needed in the future.

  9. Texture analysis of automatic graph cuts segmentations for detection of lung cancer recurrence after stereotactic radiotherapy

    Science.gov (United States)

    Mattonen, Sarah A.; Palma, David A.; Haasbeek, Cornelis J. A.; Senan, Suresh; Ward, Aaron D.

    2015-03-01

    Stereotactic ablative radiotherapy (SABR) is a treatment for early-stage lung cancer with local control rates comparable to surgery. After SABR, benign radiation induced lung injury (RILI) results in tumour-mimicking changes on computed tomography (CT) imaging. Distinguishing recurrence from RILI is a critical clinical decision determining the need for potentially life-saving salvage therapies whose high risks in this population dictate their use only for true recurrences. Current approaches do not reliably detect recurrence within a year post-SABR. We measured the detection accuracy of texture features within automatically determined regions of interest, with the only operator input being the single line segment measuring tumour diameter, normally taken during the clinical workflow. Our leave-one-out cross validation on images taken 2-5 months post-SABR showed robustness of the entropy measure, with classification error of 26% and area under the receiver operating characteristic curve (AUC) of 0.77 using automatic segmentation; the results using manual segmentation were 24% and 0.75, respectively. AUCs for this feature increased to 0.82 and 0.93 at 8-14 months and 14-20 months post SABR, respectively, suggesting even better performance nearer to the date of clinical diagnosis of recurrence; thus this system could also be used to support and reinforce the physician's decision at that time. Based on our ongoing validation of this automatic approach on a larger sample, we aim to develop a computer-aided diagnosis system which will support the physician's decision to apply timely salvage therapies and prevent patients with RILI from undergoing invasive and risky procedures.

  10. Identification of ghost artifact using texture analysis in pediatric spinal cord diffusion tensor images.

    Science.gov (United States)

    Alizadeh, Mahdi; Conklin, Chris J; Middleton, Devon M; Shah, Pallav; Saksena, Sona; Krisa, Laura; Finsterbusch, Jürgen; Faro, Scott H; Mulcahey, M J; Mohamed, Feroze B

    2018-04-01

    Ghost artifacts are a major contributor to degradation of spinal cord diffusion tensor images. A multi-stage post-processing pipeline was designed, implemented and validated to automatically remove ghost artifacts arising from reduced field of view diffusion tensor imaging (DTI) of the pediatric spinal cord. A total of 12 pediatric subjects including 7 healthy subjects (mean age=11.34years) with no evidence of spinal cord injury or pathology and 5 patients (mean age=10.96years) with cervical spinal cord injury were studied. Ghost/true cords, labeled as region of interests (ROIs), in non-diffusion weighted b0 images were segmented automatically using mathematical morphological processing. Initially, 21 texture features were extracted from each segmented ROI including 5 first-order features based on the histogram of the image (mean, variance, skewness, kurtosis and entropy) and 16s-order feature vector elements, incorporating four statistical measures (contrast, correlation, homogeneity and energy) calculated from co-occurrence matrices in directions of 0°, 45°, 90° and 135°. Next, ten features with a high value of mutual information (MI) relative to the pre-defined target class and within the features were selected as final features which were input to a trained classifier (adaptive neuro-fuzzy interface system) to separate the true cord from the ghost cord. The implemented pipeline was successfully able to separate the ghost artifacts from true cord structures. The results obtained from the classifier showed a sensitivity of 91%, specificity of 79%, and accuracy of 84% in separating the true cord from ghost artifacts. The results show that the proposed method is promising for the automatic detection of ghost cords present in DTI images of the spinal cord. This step is crucial towards development of accurate, automatic DTI spinal cord post processing pipelines. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Automated cloud classification using a ground based infra-red camera and texture analysis techniques

    Science.gov (United States)

    Rumi, Emal; Kerr, David; Coupland, Jeremy M.; Sandford, Andrew P.; Brettle, Mike J.

    2013-10-01

    Clouds play an important role in influencing the dynamics of local and global weather and climate conditions. Continuous monitoring of clouds is vital for weather forecasting and for air-traffic control. Convective clouds such as Towering Cumulus (TCU) and Cumulonimbus clouds (CB) are associated with thunderstorms, turbulence and atmospheric instability. Human observers periodically report the presence of CB and TCU clouds during operational hours at airports and observatories; however such observations are expensive and time limited. Robust, automatic classification of cloud type using infrared ground-based instrumentation offers the advantage of continuous, real-time (24/7) data capture and the representation of cloud structure in the form of a thermal map, which can greatly help to characterise certain cloud formations. The work presented here utilised a ground based infrared (8-14 μm) imaging device mounted on a pan/tilt unit for capturing high spatial resolution sky images. These images were processed to extract 45 separate textural features using statistical and spatial frequency based analytical techniques. These features were used to train a weighted k-nearest neighbour (KNN) classifier in order to determine cloud type. Ground truth data were obtained by inspection of images captured simultaneously from a visible wavelength colour camera at the same installation, with approximately the same field of view as the infrared device. These images were classified by a trained cloud observer. Results from the KNN classifier gave an encouraging success rate. A Probability of Detection (POD) of up to 90% with a Probability of False Alarm (POFA) as low as 16% was achieved.

  12. Idiopathic Pulmonary Fibrosis: Data-driven Textural Analysis of Extent of Fibrosis at Baseline and 15-Month Follow-up.

    Science.gov (United States)

    Humphries, Stephen M; Yagihashi, Kunihiro; Huckleberry, Jason; Rho, Byung-Hak; Schroeder, Joyce D; Strand, Matthew; Schwarz, Marvin I; Flaherty, Kevin R; Kazerooni, Ella A; van Beek, Edwin J R; Lynch, David A

    2017-10-01

    Purpose To evaluate associations between pulmonary function and both quantitative analysis and visual assessment of thin-section computed tomography (CT) images at baseline and at 15-month follow-up in subjects with idiopathic pulmonary fibrosis (IPF). Materials and Methods This retrospective analysis of preexisting anonymized data, collected prospectively between 2007 and 2013 in a HIPAA-compliant study, was exempt from additional institutional review board approval. The extent of lung fibrosis at baseline inspiratory chest CT in 280 subjects enrolled in the IPF Network was evaluated. Visual analysis was performed by using a semiquantitative scoring system. Computer-based quantitative analysis included CT histogram-based measurements and a data-driven textural analysis (DTA). Follow-up CT images in 72 of these subjects were also analyzed. Univariate comparisons were performed by using Spearman rank correlation. Multivariate and longitudinal analyses were performed by using a linear mixed model approach, in which models were compared by using asymptotic χ 2 tests. Results At baseline, all CT-derived measures showed moderate significant correlation (P pulmonary function. At follow-up CT, changes in DTA scores showed significant correlation with changes in both forced vital capacity percentage predicted (ρ = -0.41, P pulmonary function (P fibrosis at CT yields an index of severity that correlates with visual assessment and functional change in subjects with IPF. © RSNA, 2017.

  13. SU-E-T-30: Absorbed Doses Determined by Texture Analysis of Gafchromic EBT3 Films Using Scanning Electron Microscopy: A Feasibility Study

    International Nuclear Information System (INIS)

    Park, S; Kim, H; Ye, S

    2014-01-01

    Purpose: The texture analysis method is useful to estimate structural features of images as color, size, and shape. The study aims to determine a dose-response curve by texture analysis of Gafchromic EBT3 film images using scanning electron microscopy (SEM). Methods: The uncoated Gafchromic EBT3 films were prepared to directly scan over the active surface layer of EBT3 film using SEM. The EBT3 films were exposed at a dose range of 0 to 10 Gy using a 6 MV photon beam. The exposed film samples were SEM-scanned at 100X, 1000X, and 3000X magnifications. The four texture features (Homogeneity, Correlation, Contrast, and Energy) were calculated based on the gray level co-occurrence matrix (GLCM) derived from the SEM images at each dose. To validate a correlation between delivered doses and texture features, an R-squared value in linear regression was tested. Results: The results showed that the Correlation index was more suitable as dose indices than the other three texture features due to higher linearity and sensitivity of the dose response curves. Further the Correlation index of 3000X magnified SEM images with 9 pixel offsets had an R-squared value of 0.964. The differences between the delivered doses and the doses measured by this method were 0.9, 1.2, 0.2, and 0.2 Gy at 5, 10, 15, and 20 Gy, respectively. Conclusion: It seems to be feasible to convert micro-scale structural features of χ t χχχ he EBT3 films to absorbed doses using the texture analysis method

  14. Texture analysis of torn rotator cuff on preoperative magnetic resonance arthrography as a predictor of postoperative tendon status

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeon Ah; Lee, Guen Young; Lee, Joon Woo; Lee, Eugene; Kim, Boh Young; Kim, Su Jin; Ahn, Joong Mo; Kang, Heung Sik [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2017-08-01

    To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state. Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independently the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated. Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors. Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair.

  15. Texture analysis of torn rotator cuff on preoperative magnetic resonance arthrography as a predictor of postoperative tendon status

    International Nuclear Information System (INIS)

    Kang, Yeon Ah; Lee, Guen Young; Lee, Joon Woo; Lee, Eugene; Kim, Boh Young; Kim, Su Jin; Ahn, Joong Mo; Kang, Heung Sik

    2017-01-01

    To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state. Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independently the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated. Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors. Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair

  16. Estimation of Sensory Pork Loin Tenderness Using Warner-Bratzler Shear Force and Texture Profile Analysis Measurements.

    Science.gov (United States)

    Choe, Jee-Hwan; Choi, Mi-Hee; Rhee, Min-Suk; Kim, Byoung-Chul

    2016-07-01

    This study investigated the degree to which instrumental measurements explain the variation in pork loin tenderness as assessed by the sensory evaluation of trained panelists. Warner-Bratzler shear force (WBS) had a significant relationship with the sensory tenderness variables, such as softness, initial tenderness, chewiness, and rate of breakdown. In a regression analysis, WBS could account variations in these sensory variables, though only to a limited proportion of variation. On the other hand, three parameters from texture profile analysis (TPA)-hardness, gumminess, and chewiness-were significantly correlated with all sensory evaluation variables. In particular, from the result of stepwise regression analysis, TPA hardness alone explained over 15% of variation in all sensory evaluation variables, with the exception of perceptible residue. Based on these results, TPA analysis was found to be better than WBS measurement, with the TPA parameter hardness likely to prove particularly useful, in terms of predicting pork loin tenderness as rated by trained panelists. However, sensory evaluation should be conducted to investigate practical pork tenderness perceived by consumer, because both instrumental measurements could explain only a small portion (less than 20%) of the variability in sensory evaluation.

  17. Measurement of kinaesthetic properties of in-brine table olives by microstructure of fracture surface, sensory evaluation and texture profile analysis (TPA).

    Science.gov (United States)

    Lanza, Barbara; Amoruso, Filomena

    2018-02-02

    A series of transformations occur in olive fruit both during ripening and processing. In particular, significant changes in the microstructural composition affect the flavour, texture, nutrients and overall quality of the end product. Texture is one of the sensory quality attributes of greatest importance to consumer acceptance. In the present work, kinaesthetic properties of in-brine table olives of three cultivars of Olea europaea L. (Bella di Cerignola, Peranzana and Taggiasca cvs) were provided by several measurements of olive tissue texture by sensory, rheological and microstructural approaches. Olives at the same stage of ripening and processed with the same technology, but belonging to different cultivars, showed significant differences at microstructural, sensorial and rheological levels. To describe the relationship between the three variables, multiple regression analysis and principal component analysis were chosen. Differences in microstructure were closely related both in terms of hardness measured by texture profile analysis and hardness measured by sensory analysis. The information provided could be an aid for screening and training of a sensory panel. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  18. Textural properties of chars as determined by petrographic analysis: comparison between air-blown, oxygen-blown and oxygen-enriched gasification

    CSIR Research Space (South Africa)

    Oboirien, BO

    2012-11-01

    Full Text Available In this study, the textural properties of chars generated from a vitrinite, high ash coal in a fluidised bed gasifier under air-blown, oxygen-blown and oxygen-enriched conditions were determined by detailed petrographic analysis. The char samples...

  19. Applied Behavior Analysis Is a Science And, Therefore, Progressive

    Science.gov (United States)

    Leaf, Justin B.; Leaf, Ronald; McEachin, John; Taubman, Mitchell; Ala'i-Rosales, Shahla; Ross, Robert K.; Smith, Tristram; Weiss, Mary Jane

    2016-01-01

    Applied behavior analysis (ABA) is a science and, therefore, involves progressive approaches and outcomes. In this commentary we argue that the spirit and the method of science should be maintained in order to avoid reductionist procedures, stifled innovation, and rote, unresponsive protocols that become increasingly removed from meaningful…

  20. Interactive reliability analysis project. FY 80 progress report

    International Nuclear Information System (INIS)

    Rasmuson, D.M.; Shepherd, J.C.

    1981-03-01

    This report summarizes the progress to date in the interactive reliability analysis project. Purpose is to develop and demonstrate a reliability and safety technique that can be incorporated early in the design process. Details are illustrated in a simple example of a reactor safety system

  1. Prediction of the therapeutic response after FOLFOX and FOLFIRI treatment for patients with liver metastasis from colorectal cancer using computerized CT texture analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Su Joa, E-mail: joa0827@gmail.com [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Jung Hoon, E-mail: jhkim2008@gmail.com [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Sang Joon, E-mail: lunao78@naver.com [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Cancer Research Institute, Seoul National University, Seoul (Korea, Republic of); Han, Joon Koo, E-mail: hanjk@snu.ac.kr [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2016-10-15

    Purpose: To determine whether baseline CT texture analysis of hepatic metastasis from colorectal cancer (CRC) is predictive of therapeutic response after cytotoxic chemotherapy. Materials and methods: 235 patients with liver metastasis from CRC who underwent CT and cytotoxic chemotherapy using FOLFOX and FOLFIRI were divided into derivation cohort (n = 145) and validation cohort (n = 90). The CT texture of the hepatic metastasis was quantified using baseline CT. We analyzed the independent predictor for the response from derivation cohort and validated it using validation cohort. We also compared texture features between included four CT scanners. Results: 89 responding and 146 non-responding patients were evaluated. In the derivation cohort, lower skewness (OR, 6.739) in 2D, higher mean attenuation (OR, 2.587), and narrower standard deviation (SD) (OR, 3.163) in 3D were independently associated with response to chemotherapy. However, only lower skewness (P=0.213) on 2D and narrower SD on 3D analysis (P=0.097) did not show a significant difference on either CT scanner. When applied to the validation set, the lower skewness on 2D (AUC = 0.797) and narrower SD on 3D (AUC = 0.785) showed good performance. Conclusion: CT texture analysis is useful for prediction of therapeutic response after cytotoxic chemotherapy in patients with liver metastasis from colorectal cancer.

  2. Texture Analysis of satellite imagery in the field of biodiversity and forest structure of the Colombian Andes

    International Nuclear Information System (INIS)

    Anaya A, Jesus A; Duque L, Rosa A; Valencia H, German M

    2008-01-01

    The relationship between texture calculated from an Ikonos image with diversity and structure was evaluated along a corridor with 43 field plots in the Colombian Andes. Diversity indexes were calculated at the 43 plots and Land Use maps were used as an approach to vegetation structure. Texture was obtained from an Ikonos image using Gray Level Co-occurrence Matrix GLCM and Gray Level Difference Vector GLDV. Traditionally, texture has been interpreted from a qualitatively point of view from smooth to rough, however our approach using a matrix allows for a quantitative measurement. Texture was related to field information at two different detail levels: first with diversity measurements (Shannon Index and Richness) established at forest plots and second, with classes of a land use map (primary forest, secondary forests, forest plantation, crops and pastures) considered to be representative of vegetation structure. Results are based on relations between structure diversity,texture diversity and texture structure. Ikonos texture presents a large potential to classify forests at different successional stages however, the relation between diversity and data gathered with remote sensing is still weak. Landsat images are mentioned throughout the text as a reference or comparison with Ikonos images.

  3. Analysis of the effect of spatial resolution on texture features in the classification of breast masses in mammograms

    International Nuclear Information System (INIS)

    Rangayyan, R.M.; Nguyen, T.M.; Ayres, F.J.; Nandi, A.K.

    2007-01-01

    The present study investigates the effect of spatial resolution on co-occurrence matrix-based texture features in discriminating breast lesions as benign masses or malignant tumors. The highest classification result, in terms of the area under the receiver operating characteristics (ROC) curve, of A z 0.74, was obtained at the spatial resolution of 800 μm using all 14 of Haralick's texture features computed using the margins, or ribbons, of the breast masses as seen on mammograms. Furthermore, our study indicates that texture features computed using the ribbons resulted in higher classification accuracy than the same texture features computed using the corresponding regions of interest within the mass boundaries drawn by an expert radiologist. Classification experiments using each single texture feature showed that the texture F 8 , sum entropy, gives consistently high classification results with an average A z of 0.64 across all levels of resolution. At certain levels of resolution, the textures F 5 , F 9 , and F 11 individually gave the highest classification result with A z = 0.70. (orig.)

  4. CRUMB TEXTURE OF SPELT BREAD

    Directory of Open Access Journals (Sweden)

    Joanna Korczyk-Szabó

    2013-12-01

    Full Text Available Abstract The bread quality is considerably dependent on the texture characteristic of bread crumb. Crumb texture is an important quality indicator, as consumer prefer different bread taste. Texture analysis is primarily concerned with the evaluation of mechanical characteristics where a material is subjected to a controlled force from which a deformation curve of its response is generated. It is an objective physical examination of baked products and gives direct information on the product quality, oppositely to dough rheology tests what inform on the baking suitability of the flour, as raw material. This is why the texture analysis is one of the most helpful analytical methods of the product development. In the framework of our research during the years 2008 – 2009 were analyzed selected indicators for bread texture quality of five Triticum spelta L. varieties – Altgold, Oberkulmer Rotkorn, Ostro, Rubiota and Franckenkorn grown in an ecological system. The bread texture quality was evaluated on texture analyzer TA.XT Plus (Stable Micro Systems, Surrey, UK, following the AACC (74-09 standard method and expressed as crumb firmness (N, stiffness (N.mm-1 and relative elasticity (%. Our research proved that all selected indicators were significantly influenced by the year of growing and variety. The most soft bread was achieved in Rubiota, whereas bread crumb samples from Franckenkorn and Altgold were the most firm and stiff. Correlation analysis showed strong negative correlation between relative elasticity and bread crumb firmness as well as bread stiffness (-0.81++, -0.78++. The spelt grain can be a good source for making bread flour, but is closely dependent on choice of spelt variety. The spelt wheat bread crumb texture need further investigation as it can be a reliable quality parameter.

  5. Tumour heterogeneity in non-small cell lung carcinoma assessed by CT texture analysis: a potential marker of survival

    International Nuclear Information System (INIS)

    Ganeshan, Balaji; Miles, Ken; Panayiotou, Elleny; Burnand, Kate; Dizdarevic, Sabina

    2012-01-01

    To establish the potential for tumour heterogeneity in non-small cell lung cancer (NSCLC) as assessed by CT texture analysis (CTTA) to provide an independent marker of survival for patients with NSCLC. Tumour heterogeneity was assessed by CTTA of unenhanced images of primary pulmonary lesions from 54 patients undergoing 18 F-fluorodeoxyglucose (FDG) PET-CT for staging of NSCLC. CTTA comprised image filtration to extract fine, medium and coarse features with quantification of the distribution of pixel values (uniformity) within the filtered images. Receiver operating characteristics identified thresholds for PET and CTTA parameters that were related to patient survival using Kaplan-Meier analysis. The median (range) survival was 29.5 (1-38) months. 24, 10, 14 and 6 patients had tumour stages I, II, III and IV respectively. PET stage and tumour heterogeneity assessed by CTTA were significant independent predictors of survival (PET stage: Odds ratio 3.85, 95% confidence limits 0.9-8.09, P = 0.002; CTTA: Odds ratio 56.4, 95% confidence limits 4.79-666, p = 0.001). SUV was not a significantly associated with survival. Assessment of tumour heterogeneity by CTTA of non-contrast enhanced images has the potential for to provide a novel, independent predictor of survival for patients with NSCLC. (orig.)

  6. Automatic Detection of Optic Disc in Retinal Image by Using Keypoint Detection, Texture Analysis, and Visual Dictionary Techniques

    Directory of Open Access Journals (Sweden)

    Kemal Akyol

    2016-01-01

    Full Text Available With the advances in the computer field, methods and techniques in automatic image processing and analysis provide the opportunity to detect automatically the change and degeneration in retinal images. Localization of the optic disc is extremely important for determining the hard exudate lesions or neovascularization, which is the later phase of diabetic retinopathy, in computer aided eye disease diagnosis systems. Whereas optic disc detection is fairly an easy process in normal retinal images, detecting this region in the retinal image which is diabetic retinopathy disease may be difficult. Sometimes information related to optic disc and hard exudate information may be the same in terms of machine learning. We presented a novel approach for efficient and accurate localization of optic disc in retinal images having noise and other lesions. This approach is comprised of five main steps which are image processing, keypoint extraction, texture analysis, visual dictionary, and classifier techniques. We tested our proposed technique on 3 public datasets and obtained quantitative results. Experimental results show that an average optic disc detection accuracy of 94.38%, 95.00%, and 90.00% is achieved, respectively, on the following public datasets: DIARETDB1, DRIVE, and ROC.

  7. Role of zein proteins in structure and assembly of protein bodies and endosperm texture. Progress report and appendix 1 - preliminary data

    Energy Technology Data Exchange (ETDEWEB)

    Larkins, B.

    1997-05-01

    Although funding for this project was initiated less than two years ago, we have made significant progress with our research objectives. We have cloned the gene responsible for the fl2 mutation. In fl2, the mutant phenotype appears to result from a defective signal peptide in an alpha-zein protein. As a consequence, the signal peptide remains attached when the protein accumulates in the protein body. A mutation like fl2 could explain other semidominant and dominant opaque mutants on the basis of abnormal zein polypeptides. A manuscript describing the research that led to the cloning of fl2 is in press, and a second manuscript on the characterization of this gene has been prepared for publication. We found that increased amounts of the 27-kD gamma-zein protein enlarge the proportion of vitreous endosperm and increases the hardness of o2 mutants. This protein also enhances these properties in wild type seeds. The mechanism by which the gamma-zein protein brings about these changes is unclear, and is under investigation. We have found and characterized several mutants that reduce gamma-zein synthesis. The mutations do not significantly affect synthesis of any other type of zein protein. They appear to create an opaque phenotype by reducing the number rather than the size of protein bodies. Interestingly, the mutant seeds fail to germinate. A manuscript describing one of these mutants, o15, has been prepared for publication. We have created a number of transgenic tobacco plants that can produce alpha-, beta-, gamma(27-kD)-, or delta-zeins, as well as combinations of these proteins. Analysis of seeds from these plants and crosses of these plants has shown that tobacco endosperm can serve as a heterologous system to study zein interactions. We have obtained evidence that interactions between alpha- and gamma-zein proteins are required for stable accumulation of alpha-zeins in the endosperm. These and other preliminary results are illustrated in Appendix 1.

  8. Quantitative CT texture and shape analysis: Can it differentiate benign and malignant mediastinal lymph nodes in patients with primary lung cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Bayanati, Hamid; Thornhill, Rebecca E.; Souza, Carolina A.; Sethi-Virmani, Vineeta; Gupta, Ashish; Dennie, Carole [University of Ottawa, The Ottawa Hospital Research Institute, Department of Medical Imaging, The Ottawa Hospital, 501 Smyth Road, Box 232, Ottawa, ON (Canada); Maziak, Donna [University of Ottawa, The Ottawa Hospital Research Institute, Department of Surgery - Division of Thoracic Surgery, The Ottawa Hospital, Ottawa, ON (Canada); Amjadi, Kayvan [University of Ottawa, The Ottawa Hospital Research Institute, Department of Respiratory Medicine, The Ottawa Hospital, Ottawa, ON (Canada)

    2014-09-13

    To assess the accuracy of CT texture and shape analysis in the differentiation of benign and malignant mediastinal nodes in lung cancer. Forty-three patients with biopsy-proven primary lung malignancy with pathological mediastinal nodal staging and unenhanced CT of the thorax were studied retrospectively. Grey-level co-occurrence and run-length matrix textural features, as well as morphological features, were extracted from 72 nodes. Differences between benign and malignant features were assessed using Mann-Whitney U tests. Receiver operating characteristic (ROC) curves for each were constructed and the area under the curve (AUC) calculated with histopathology diagnosis as outcome. Combinations of features were also entered as predictors in logistic regression models and optimal threshold criteria were used to estimate sensitivity and specificity. Using optimum-threshold criteria, the combined textural and shape features identified malignant mediastinal nodes with 81 % sensitivity and 80 % specificity (AUC = 0.87, P < 0.0001). Using this combination, 84 % malignant and 71 % benign nodes were correctly classified. Quantitative CT texture and shape analysis has the potential to accurately differentiate malignant and benign mediastinal nodes in lung cancer. (orig.)

  9. Time-Frequency Feature Representation Using Multi-Resolution Texture Analysis and Acoustic Activity Detector for Real-Life Speech Emotion Recognition

    Directory of Open Access Journals (Sweden)

    Kun-Ching Wang

    2015-01-01

    Full Text Available The classification of emotional speech is mostly considered in speech-related research on human-computer interaction (HCI. In this paper, the purpose is to present a novel feature extraction based on multi-resolutions texture image information (MRTII. The MRTII feature set is derived from multi-resolution texture analysis for characterization and classification of different emotions in a speech signal. The motivation is that we have to consider emotions have different intensity values in different frequency bands. In terms of human visual perceptual, the texture property on multi-resolution of emotional speech spectrogram should be a good feature set for emotion classification in speech. Furthermore, the multi-resolution analysis on texture can give a clearer discrimination between each emotion than uniform-resolution analysis on texture. In order to provide high accuracy of emotional discrimination especially in real-life, an acoustic activity detection (AAD algorithm must be applied into the MRTII-based feature extraction. Considering the presence of many blended emotions in real life, in this paper make use of two corpora of naturally-occurring dialogs recorded in real-life call centers. Compared with the traditional Mel-scale Frequency Cepstral Coefficients (MFCC and the state-of-the-art features, the MRTII features also can improve the correct classification rates of proposed systems among different language databases. Experimental results show that the proposed MRTII-based feature information inspired by human visual perception of the spectrogram image can provide significant classification for real-life emotional recognition in speech.

  10. 17th International Conference on Textures of Materials (ICOTOM 17)

    International Nuclear Information System (INIS)

    Skrotzki, Werner; Oertel, Carl-Georg

    2015-01-01

    The 17th International Conference on Textures of Materials (ICOTOM 17) took place in Dresden, Germany, August 24-29, 2014. It belongs to the 'triennial' series of ICOTOM meetings with a long tradition, starting in 1969 - Clausthal, 1971 - Cracow, 1973 - Pont-à-Mousson, 1975 - Cambridge, 1978 - Aachen, 1981 - Tokyo, 1984 - Noordwijkerhout, 1987 - Santa Fe, 1990 - Avignon, 1993 - Clausthal, 1996 - Xian, 1999 - Montreal, 2002 - Seoul, 2005 - Leuven, 2008 - Pittsburgh, 2011 - Mumbai, 2014 - Dresden. ICOTOM 17 was hosted by the Dresden University of Technology, Institute of Structural Physics. Following the tradition of the ICOTOM conferences, the main focus of ICOTOM-17 was to promote and strengthen the fundamental understanding of the basic processes that govern the formation of texture and its relation to the properties of polycrystalline materials. Nonetheless, it was the aim to forge links between basic research on model materials and applied research on engineering materials of technical importance. Thus, ICOTOM 17 provided a forum for the presentation and discussion of recent progress in research of texture and related anisotropy of mechanical and functional properties of all kinds of polycrystalline materials including natural materials like rocks. Particular attention was paid to recent advances in texture measurement and analysis as well as modeling of texture development for all kinds of processes like solidification, plastic deformation, recrystallization and grain growth, phase transformations, thin film deposition, etc. Hence, ICOTOM 17 was of great interest to materials scientists, engineers from many different areas and geoscientists. The topics covered by ICOTOM 17 were: 1. Mathematical, numerical and statistical methods of texture analysis 2. Deformation textures 3. Crystallization, recrystallization and growth textures 4. Transformation textures 5. Textures in functional materials 6. Textures in advanced materials 7. Textures in rocks 8

  11. Comparison of fabric analysis of snow samples by Computer-Integrated Polarization Microscopy and Automatic Ice Texture Analyzer

    Science.gov (United States)

    Leisinger, Sabine; Montagnat, Maurine; Heilbronner, Renée; Schneebeli, Martin

    2014-05-01

    Accurate knowledge of fabric anisotropy is crucial to understand the mechanical behavior of snow and firn, but is also important for understanding metamorphism. Computer-Integrated Polarization Microscopy (CIP) method used for the fabric analysis was developed by Heilbronner and Pauli in the early 1990ies and uses a slightly modified traditional polarization microscope for the fabric analysis. First developed for quartz, it can be applied to other uniaxial minerals. Up to now this method was mainly used in structural geology. However, it is also well suited for the fabric analysis of snow, firn and ice. The method is based on the analysis of first- order interference colors images by a slightly modified optical polarization microscope, a grayscale camera and a computer. The optical polarization microscope is featured with high quality objectives, a rotating table and two polarizers that can be introduced above and below the thin section, as well as a full wave plate. Additionally, two quarter-wave plates for circular polarization are needed. Otherwise it is also possible to create circular polarization from a set of crossed polarized images through image processing. A narrow band interference filter transmitting a wavelength between 660 and 700 nm is also required. Finally a monochrome digital camera is used to capture the input images. The idea is to record the change of interference colors while the thin section is being rotated once through 180°. The azimuth and inclination of the c-axis are defined by the color change. Recording the color change through a red filter produces a signal with a well-defined amplitude and phase angle. An advantage of this method lies in the simple conversion of an ordinary optical microscope to a fabric analyzer. The Automatic Ice Texture Analyzer (AITA) as the first fully functional instrument to measure c-axis orientation was developed by Wilson and other (2003). Most recent fabric analysis of snow and firn samples was carried

  12. Discrimination of Vegetation Height Categories With Passive Satellite Sensor Imagery Using Texture Analysis

    NARCIS (Netherlands)

    Petrou, Z.; Manakos, I.; Stathaki, T.; Mücher, C.A.; Adamo, M.

    2015-01-01

    Vegetation height is a crucial factor in environmental studies, landscape analysis, and mapping applications. Its estimation may prove cost and resource demanding, e.g., employing light detection and ranging (LiDAR) data. This study presents a cost-effective framework for height estimation, built

  13. Texture Analysis using The Neutron Diffraction Method on The Non Standardized Austenitic Steel Process by Machining,Annealing, and Rolling

    Directory of Open Access Journals (Sweden)

    Tri Hardi Priyanto

    2016-04-01

    Full Text Available Austenitic steel is one type of stainless steel which is widely used in the industry. Many studies on  austenitic stainless steel have been performed to determine the physicalproperties using various types of equipment and methods. In this study, the neutron diffraction method is used to characterize the materials which have been made from  minerals extracted from the mines in Indonesia. The materials consist of a granular ferro-scrap, nickel, ferro-chrome, ferro-manganese, and ferro-silicon added with a little titanium. Characterization of the materials was carried out in threeprocesses, namely: machining, annealing, and rolling. Experimental results obtained from the machining process generally produces a texture in the 〈100〉direction. From the machining to annealing process, the texture index decreases from 3.0164 to 2.434.Texture strength in the machining process (BA2N sample is  8.13 mrd and it then decreases to 6.99 in the annealing process (A2DO sample. In the annealing process the three-component texture appears, cube-on-edge type texture{110}〈001〉, cube-type texture {001}〈100〉, and brass-type {110}〈112〉. The texture is very strong leading to the direction of orientation {100}〈001〉, while the {011}〈100〉is weaker than that of the {001}, and texture withorientation {110}〈112〉is weak. In the annealing process stress release occurred, and this was shown by more randomly pole compared to stress release by the machining process. In the rolling process a brass-type texture{110}〈112〉with a spread towards the goss-type texture {110}〈001〉 appeared,  and  the  brass  component  is markedly  reinforced  compared  to  the undeformed state (before rolling. Moreover, the presence of an additional {110} component was observed at the center of the (110 pole figure. The pole density of three components increases withthe increasing degree of thickness reduction. By increasing degrees

  14. Analysis of image versus position, scale and direction reveals pattern texture anisotropy

    Directory of Open Access Journals (Sweden)

    Roland eLehoucq

    2015-01-01

    Full Text Available Pattern heterogeneities and anisotropies often carry significant physical information. We provide a toolbox which: (i cumulates analysis in terms of position, direction and scale; (ii is as general as possible; (iii is simple and fast to understand, implement, execute and exploit.It consists in dividing the image into analysis boxes at a chosen scale; in each box an ellipse (the inertia tensor is fitted to the signal and thus determines the direction in which the signal is more present. This tensor can be averaged in position and/or be used to study the dependence with scale. This choice is formally linked with Leray transforms and anisotropic wavelet analysis. Such protocol is intutively interpreted and consistent with what the eye detects: relevant scales, local variations in space, priviledged directions. It is fast and parallelizable.Its several variants are adaptable to the user's data and needs. It is useful to statistically characterize anisotropies of 2D or 3D patterns in which individual objects are not easily distinguished, with only minimal pre-processing of the raw image, and more generally applies to data in higher dimensions.It is less sensitive to edge effects, and thus better adapted for a multiscale analysis down to small scale boxes, than pair correlation function or Fourier transform.Easy to understand and implement,it complements more sophisticated methods such as Hough transform or diffusion tensor imaging.We use it on various fracture patterns (sea ice cover, thin sections of granite, granular materials, to pinpoint the maximal anisotropy scales. The results are robust to noise and to user choices. This toolbox could turn also useful for granular materials, hard condensed matter, geophysics, thin films, statistical mechanics, characterisation of networks, fluctuating amorphous systems, inhomogeneous and disordered systems, or medical imaging, among others.

  15. Ion beam texturing

    Science.gov (United States)

    Hudson, W. R.

    1977-01-01

    A microscopic surface texture was created by sputter-etching a surface while simultaneously sputter-depositing a lower sputter yield material onto the surface. A xenon ion-beam source was used to perform the texturing process on samples as large as 3-cm diameter. Textured surfaces have been characterized with SEM photomicrographs for a large number of materials including Cu, Al, Si, Ti, Ni, Fe, stainless steel, Au, and Ag. A number of texturing parameters are studied including the variation of texture with ion-beam powder, surface temperature, and the rate of texture growth with sputter etching time.

  16. TEXTURAL DESCRIPTORS FOR MULTIPHASIC ORE PARTICLES

    Directory of Open Access Journals (Sweden)

    Laura Pérez-Barnuevo

    2012-11-01

    Full Text Available Monitoring of mineral processing circuits by means of particle liberation analysis through quantitative image analysis has become a routine technique within the last decades. Usually, liberation indices are computed as weight proportions, which is not informative enough when complex texture ores are treated by flotation. In these cases, liberation has to be computed as phase surface exposed to reactants, and textural relationships between minerals have to be characterized to determine the possibility of increasing exposure. In this paper, some indices to achieve a complete texture characterization have been developed in terms of 2D phase contact and mineral surfaces exposure. Indices suggested by other authors are also compared. The response of this set of parameters against textural changes has been explored on simple synthetic textures ranging from single to multiple inclusions and single to multiple veins and their ability to discriminate between different textural features is analyzed over real mineral particles with known internal structure.

  17. Some distinguishing characteristics of contour and texture phenomena in images

    Science.gov (United States)

    Jobson, Daniel J.

    1992-01-01

    The development of generalized contour/texture discrimination techniques is a central element necessary for machine vision recognition and interpretation of arbitrary images. Here, the visual perception of texture, selected studies of texture analysis in machine vision, and diverse small samples of contour and texture are all used to provide insights into the fundamental characteristics of contour and texture. From these, an experimental discrimination scheme is developed and tested on a battery of natural images. The visual perception of texture defined fine texture as a subclass which is interpreted as shading and is distinct from coarse figural similarity textures. Also, perception defined the smallest scale for contour/texture discrimination as eight to nine visual acuity units. Three contour/texture discrimination parameters were found to be moderately successful for this scale discrimination: (1) lightness change in a blurred version of the image, (2) change in lightness change in the original image, and (3) percent change in edge counts relative to local maximum.

  18. [Research progresses of anabolic steroids analysis in doping control].

    Science.gov (United States)

    Long, Yuanyuan; Wang, Dingzhong; Li, Ke'an; Liu, Feng

    2008-07-01

    Anabolic steroids, a kind of physiological active substance, are widely abused to improve athletic performance in human sports. They have been forbidden in sports by the International Olympic Committee since 1983. Since then, many researchers have been focusing their attentions on the establishment of reliable detection methods. In this paper, we review the research progresses of different analytical methods for anabolic steroids since 2002, such as gas chromatography-mass spectrometry, liquid chromatography-mass spectrometry, immunoassay, electrochemistry analysis and mass spectrometry. The developing prospect of anabolic steroids analysis is also discussed.

  19. Tribological analysis of the ventral scale structure in a Python regius in relation to laser textured surfaces

    International Nuclear Information System (INIS)

    Abdel-Aal, H A; El Mansori, M

    2013-01-01

    Laser texturing is one of the leading technologies applied to modify surface topography. To date, however, a standardized procedure to generate deterministic textures is virtually non-existent. In nature, especially in squamata, there are many examples of deterministic structured textures that allow species to control friction and condition their tribological response for efficient function. In this work, we draw a comparison between industrial surfaces and reptilian surfaces. We chose the Python regius species as a bio-analogue with a deterministic surface. We first study the structural make up of the ventral scales of the snake (both construction and metrology). We further compare the metrological features of the ventral scales to experimentally recommended performance indicators of industrial surfaces extracted from open literature. The results indicate the feasibility of engineering a laser textured surface based on the reptilian ornamentation constructs. It is shown that the metrological features, key to efficient function of a rubbing deterministic surface, are already optimized in the reptile. We further show that optimization in reptilian surfaces is based on synchronizing surface form, textures and aspects to condition the frictional response. Mimicking reptilian surfaces, we argue, may form a design methodology potentially capable of generating advanced deterministic surface constructs capable of efficient tribological function. (paper)

  20. Bone Texture Fractal Dimension Analysis of Ultrasound-Treated Bone around Implant Site: A Double-Blind Clinical Trial

    Directory of Open Access Journals (Sweden)

    Elaf Akram Abdulhameed

    2018-01-01

    Full Text Available Objectives. To evaluate the efficacy of bone texture fractal dimension (FD analysis method in predicting implant stability from intraoral periapical radiographs using two implant protocols. Materials and Methods. A double-blind clinical trial was conducted on 22 subjects who needed dental implants. The participants were randomized into two groups, the control group with standard implant protocol treatment and the intervention group with added low-intensity power ultrasound treatment (LIPUS besides the standard implant protocol. The FD values of bone density were carried out on the mesial and distal sides of the implant on digital intraoral radiographs using the box-counting method. Both resonance frequency (RF and fractal dimension (FD were assessed in three time intervals: after surgery and before and after loading. Results. FD on both the mesial and distal sides serve as very good-to-excellent tests with high validity (ROC area exceeding 0.8 in predicting high implant stability (ISQ ≥ 70. The mesial side measurements were consistently better than the distal side among the intervention groups. The optimum cutoff value for the FD-mesial side that predicts a highly stable implant (ISQ ≥ 70 is ≥1.505. At this optimum cutoff value, the mesial side FD is associated with a perfect sensitivity (100% and fairly high specificity (86.5%. Conclusion. The FD analysis could be recommended as an adjunctive quantitative method in prediction of the implant stability with very high sensitivity and specificity. This trial is registered with ISRCTN72648040.

  1. Assessment of tumor heterogeneity by CT texture analysis: Can the largest cross-sectional area be used as an alternative to whole tumor analysis?

    International Nuclear Information System (INIS)

    Ng, Francesca; Kozarski, Robert; Ganeshan, Balaji; Goh, Vicky

    2013-01-01

    Objective: To determine if there is a difference between contrast enhanced CT texture features from the largest cross-sectional area versus the whole tumor, and its effect on clinical outcome prediction. Methods: Entropy (E) and uniformity (U) were derived for different filter values (1.0–2.5: fine to coarse textures) for the largest primary tumor cross-sectional area and the whole tumor of the staging contrast enhanced CT in 55 patients with primary colorectal cancer. Parameters were compared using non-parametric Wilcoxon test. Kaplan–Meier analysis was performed to determine the relationship between CT texture and 5-year overall survival. Results: E was higher and U lower for the whole tumor indicating greater heterogeneity at all filter levels (1.0–2.5): median (range) for E and U for whole tumor versus largest cross-sectional area of 7.89 (7.43–8.31) versus 7.62 (6.94–8.08) and 0.005 (0.004–0.01) versus 0.006 (0.005–0.01) for filter 1.0; 7.88 (7.22–8.48) versus 7.54 (6.86–8.1) and 0.005 (0.003–0.01) versus 0.007 (0.004–0.01) for filter 1.5; 7.88 (7.17–8.54) versus 7.48 (5.84–8.25) and 0.005 (0.003–0.01) versus 0.007 (0.004–0.02) for filter 2.0; and 7.83 (7.03–8.57) versus 7.42 (5.19–8.26) and 0.005 (0.003–0.01) versus 0.006 (0.004–0.03) for filter 2.5 respectively (p ≤ 0.001). Kaplan–Meier analysis demonstrated better separation of E and U for whole tumor analysis for 5-year overall survival. Conclusion: Whole tumor analysis appears more representative of tumor heterogeneity

  2. SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

    International Nuclear Information System (INIS)

    Fang, Y; Huang, H; Su, T

    2015-01-01

    Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination

  3. Cascaded Amplitude Modulations in Sound Texture Perception

    Directory of Open Access Journals (Sweden)

    Richard McWalter

    2017-09-01

    Full Text Available Sound textures, such as crackling fire or chirping crickets, represent a broad class of sounds defined by their homogeneous temporal structure. It has been suggested that the perception of texture is mediated by time-averaged summary statistics measured from early auditory representations. In this study, we investigated the perception of sound textures that contain rhythmic structure, specifically second-order amplitude modulations that arise from the interaction of different modulation rates, previously described as “beating” in the envelope-frequency domain. We developed an auditory texture model that utilizes a cascade of modulation filterbanks that capture the structure of simple rhythmic patterns. The model was examined in a series of psychophysical listening experiments using synthetic sound textures—stimuli generated using time-averaged statistics measured from real-world textures. In a texture identification task, our results indicated that second-order amplitude modulation sensitivity enhanced recognition. Next, we examined the contribution of the second-order modulation analysis in a preference task, where the proposed auditory texture model was preferred over a range of model deviants that lacked second-order modulation rate sensitivity. Lastly, the discriminability of textures that included second-order amplitude modulations appeared to be perceived using a time-averaging process. Overall, our results demonstrate that the inclusion of second-order modulation analysis generates improvements in the perceived quality of synthetic textures compared to the first-order modulation analysis considered in previous approaches.

  4. Using texture analysis to improve per-pixel classification of very high resolution images for mapping plastic greenhouses

    Science.gov (United States)

    Agüera, Francisco; Aguilar, Fernando J.; Aguilar, Manuel A.

    The area occupied by plastic-covered greenhouses has undergone rapid growth in recent years, currently exceeding 500,000 ha worldwide. Due to the vast amount of input (water, fertilisers, fuel, etc.) required, and output of different agricultural wastes (vegetable, plastic, chemical, etc.), the environmental impact of this type of production system can be serious if not accompanied by sound and sustainable territorial planning. For this, the new generation of satellites which provide very high resolution imagery, such as QuickBird and IKONOS can be useful. In this study, one QuickBird and one IKONOS satellite image have been used to cover the same area under similar circumstances. The aim of this work was an exhaustive comparison of QuickBird vs. IKONOS images in land-cover detection. In terms of plastic greenhouse mapping, comparative tests were designed and implemented, each with separate objectives. Firstly, the Maximum Likelihood Classification (MLC) was applied using five different approaches combining R, G, B, NIR, and panchromatic bands. The combinations of the bands used, significantly influenced some of the indexes used to classify quality in this work. Furthermore, the quality classification of the QuickBird image was higher in all cases than that of the IKONOS image. Secondly, texture features derived from the panchromatic images at different window sizes and with different grey levels were added as a fifth band to the R, G, B, NIR images to carry out the MLC. The inclusion of texture information in the classification did not improve the classification quality. For classifications with texture information, the best accuracies were found in both images for mean and angular second moment texture parameters. The optimum window size in these texture parameters was 3×3 for IK images, while for QB images it depended on the quality index studied, but the optimum window size was around 15×15. With regard to the grey level, the optimum was 128. Thus, the

  5. Classification of brain tumors using texture based analysis of T1-post contrast MR scans in a preclinical model

    Science.gov (United States)

    Tang, Tien T.; Zawaski, Janice A.; Francis, Kathleen N.; Qutub, Amina A.; Gaber, M. Waleed

    2018-02-01

    Accurate diagnosis of tumor type is vital for effective treatment planning. Diagnosis relies heavily on tumor biopsies and other clinical factors. However, biopsies do not fully capture the tumor's heterogeneity due to sampling bias and are only performed if the tumor is accessible. An alternative approach is to use features derived from routine diagnostic imaging such as magnetic resonance (MR) imaging. In this study we aim to establish the use of quantitative image features to classify brain tumors and extend the use of MR images beyond tumor detection and localization. To control for interscanner, acquisition and reconstruction protocol variations, the established workflow was performed in a preclinical model. Using glioma (U87 and GL261) and medulloblastoma (Daoy) models, T1-weighted post contrast scans were acquired at different time points post-implant. The tumor regions at the center, middle, and peripheral were analyzed using in-house software to extract 32 different image features consisting of first and second order features. The extracted features were used to construct a decision tree, which could predict tumor type with 10-fold cross-validation. Results from the final classification model demonstrated that middle tumor region had the highest overall accuracy at 79%, while the AUC accuracy was over 90% for GL261 and U87 tumors. Our analysis further identified image features that were unique to certain tumor region, although GL261 tumors were more homogenous with no significant differences between the central and peripheral tumor regions. In conclusion our study shows that texture features derived from MR scans can be used to classify tumor type with high success rates. Furthermore, the algorithm we have developed can be implemented with any imaging datasets and may be applicable to multiple tumor types to determine diagnosis.

  6. Cascaded Amplitude Modulations in Sound Texture Perception

    DEFF Research Database (Denmark)

    McWalter, Richard Ian; Dau, Torsten

    2017-01-01

    . In this study, we investigated the perception of sound textures that contain rhythmic structure, specifically second-order amplitude modulations that arise from the interaction of different modulation rates, previously described as "beating" in the envelope-frequency domain. We developed an auditory texture...... model that utilizes a cascade of modulation filterbanks that capture the structure of simple rhythmic patterns. The model was examined in a series of psychophysical listening experiments using synthetic sound textures-stimuli generated using time-averaged statistics measured from real-world textures....... In a texture identification task, our results indicated that second-order amplitude modulation sensitivity enhanced recognition. Next, we examined the contribution of the second-order modulation analysis in a preference task, where the proposed auditory texture model was preferred over a range of model...

  7. Nano-Aptasensing in Mycotoxin Analysis: Recent Updates and Progress

    Directory of Open Access Journals (Sweden)

    Amina Rhouati

    2017-10-01

    Full Text Available Recent years have witnessed an overwhelming integration of nanomaterials in the fabrication of biosensors. Nanomaterials have been incorporated with the objective to achieve better analytical figures of merit in terms of limit of detection, linear range, assays stability, low production cost, etc. Nanomaterials can act as immobilization support, signal amplifier, mediator and artificial enzyme label in the construction of aptasensors. We aim in this work to review the recent progress in mycotoxin analysis. This review emphasizes on the function of the different nanomaterials in aptasensors architecture. We subsequently relate their features to the analytical performance of the given aptasensor towards mycotoxins monitoring. In the same context, a critically analysis and level of success for each nano-aptasensing design will be discussed. Finally, current challenges in nano-aptasensing design for mycotoxin analysis will be highlighted.

  8. Probabilistic Accident Progression Analysis with application to a LMFBR design

    International Nuclear Information System (INIS)

    Jamali, K.M.

    1982-01-01

    A method for probabilistic analysis of accident sequences in nuclear power plant systems referred to as ''Probabilistic Accident Progression Analysis'' (PAPA) is described. Distinctive features of PAPA include: (1) definition and analysis of initiator-dependent accident sequences on the component level; (2) a new fault-tree simplification technique; (3) a new technique for assessment of the effect of uncertainties in the failure probabilities in the probabilistic ranking of accident sequences; (4) techniques for quantification of dependent failures of similar components, including an iterative technique for high-population components. The methodology is applied to the Shutdown Heat Removal System (SHRS) of the Clinch River Breeder Reactor Plant during its short-term (0 -2 . Major contributors to this probability are the initiators loss of main feedwater system, loss of offsite power, and normal shutdown

  9. Machine learning-based quantitative texture analysis of CT images of small renal masses. Differentiation of angiomyolipoma without visible fat from renal cell carcinoma

    International Nuclear Information System (INIS)

    Feng, Zhichao; Rong, Pengfei; Zhou, Qingyu; Zhu, Wenwei; Yan, Zhimin; Liu, Qianyun; Wang, Wei; Cao, Peng

    2018-01-01

    To evaluate the diagnostic performance of machine-learning based quantitative texture analysis of CT images to differentiate small (≤ 4 cm) angiomyolipoma without visible fat (AMLwvf) from renal cell carcinoma (RCC). This single-institutional retrospective study included 58 patients with pathologically proven small renal mass (17 in AMLwvf and 41 in RCC groups). Texture features were extracted from the largest possible tumorous regions of interest (ROIs) by manual segmentation in preoperative three-phase CT images. Interobserver reliability and the Mann-Whitney U test were applied to select features preliminarily. Then support vector machine with recursive feature elimination (SVM-RFE) and synthetic minority oversampling technique (SMOTE) were adopted to establish discriminative classifiers, and the performance of classifiers was assessed. Of the 42 extracted features, 16 candidate features showed significant intergroup differences (P < 0.05) and had good interobserver agreement. An optimal feature subset including 11 features was further selected by the SVM-RFE method. The SVM-RFE+SMOTE classifier achieved the best performance in discriminating between small AMLwvf and RCC, with the highest accuracy, sensitivity, specificity and AUC of 93.9 %, 87.8 %, 100 % and 0.955, respectively. Machine learning analysis of CT texture features can facilitate the accurate differentiation of small AMLwvf from RCC. (orig.)

  10. Progressive reduction of the thermal wall system by modal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mokhtari, A.; Meslem, A.; Bounif, A.; Kadi, L. [Universite des Sciences et de la Technologie, Oran (Algeria)

    1993-12-31

    A reduction method of thermal systems called ``progress`` using the modal Analysis is presented. It allows to do, at each time of simulation, a synthesis information in the system evolution. Consequently, the limited number of descriptive and significant parameters (proper modes), can produce some extremely useful indication about dynamic evolution. However this method can eliminate proper modes of which the energetic contribution will be neglected or amortized. Some examples were studied, showing the efficiency of this method by reducing the computing time, as well as, having high precision on predicted dynamic response over time of simulation. (Authors). 4 refs., 4 figs.

  11. Genetic analysis of kernel texture (grain hardness) in a hard red spring wheat (Triticum aestivum L.) bi-parental population

    Science.gov (United States)

    Grain hardness is a very important trait in determining wheat market class and also influences milling and baking traits. At the grain Hardness (Ha) locus on chromosome 5DS, there are two primary mutations responsible for conveying a harder kernel texture among U.S. hard red spring wheats: (1) the P...

  12. Local binary pattern variants-based adaptive texture features analysis for posed and nonposed facial expression recognition

    Science.gov (United States)

    Sultana, Maryam; Bhatti, Naeem; Javed, Sajid; Jung, Soon Ki

    2017-09-01

    Facial expression recognition (FER) is an important task for various computer vision applications. The task becomes challenging when it requires the detection and encoding of macro- and micropatterns of facial expressions. We present a two-stage texture feature extraction framework based on the local binary pattern (LBP) variants and evaluate its significance in recognizing posed and nonposed facial expressions. We focus on the parametric limitations of the LBP variants and investigate their effects for optimal FER. The size of the local neighborhood is an important parameter of the LBP technique for its extraction in images. To make the LBP adaptive, we exploit the granulometric information of the facial images to find the local neighborhood size for the extraction of center-symmetric LBP (CS-LBP) features. Our two-stage texture representations consist of an LBP variant and the adaptive CS-LBP features. Among the presented two-stage texture feature extractions, the binarized statistical image features and adaptive CS-LBP features were found showing high FER rates. Evaluation of the adaptive texture features shows competitive and higher performance than the nonadaptive features and other state-of-the-art approaches, respectively.

  13. Tumour heterogeneity in oesophageal cancer assessed by CT texture analysis: Preliminary evidence of an association with tumour metabolism, stage, and survival

    International Nuclear Information System (INIS)

    Ganeshan, B.; Skogen, K.; Pressney, I.; Coutroubis, D.; Miles, K.

    2012-01-01

    Aim: To undertake a pilot study assessing whether tumour heterogeneity evaluated using computed tomography texture analysis (CTTA) has the potential to provide a marker of tumour aggression and prognosis in oesophageal cancer. Materials and methods: In 21 patients, unenhanced CT images of the primary oesophageal lesion obtained using positron-emission tomography (PET)-CT examinations underwent CTTA. CTTA was carried out using a software algorithm that selectively filters and extracts textures at different anatomical scales between filter values 1.0 (fine detail) and 2.5 (coarse features) with quantification as entropy and uniformity (measures image heterogeneity). Texture parameters were correlated with average tumour 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) uptake [standardized uptake values (SUV mean and SUV max )] and clinical staging as determined by endoscopic ultrasound (nodal involvement) and PET-CT (distant metastases). The relationship between tumour stage, FDG uptake, and texture with survival was assessed using Kaplan–Meier analysis. Results: Tumour heterogeneity correlated with SUV max and SUV mean . The closest correlations were found for SUV mean measured as uniformity and entropy with coarse filtration (r = –0.754, p < 0.0001; and r = 0.748, p = 0.0001 respectively). Heterogeneity was also significantly greater in patients with clinical stage III or IV for filter values between 1.0 and 2.0 (maximum difference at filter value 1.5: entropy: p = 0.027; uniformity p = 0.032). The median (range) survival was 21 (4–34) months. Tumour heterogeneity assessed by CTTA (coarse uniformity) was an independent predictor of survival [odds ratio (OR)=4.45 (95% CI: 1.08, 18.37); p = 0.039]. Conclusion: CTTA assessment of tumour heterogeneity has the potential to identify oesophageal cancers with adverse biological features and provide a prognostic indicator of survival.

  14. Development and validation of a prognostic model incorporating texture analysis derived from standardised segmentation of PET in patients with oesophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Foley, Kieran G. [Cardiff University, Division of Cancer and Genetics, Cardiff (United Kingdom); Hills, Robert K. [Cardiff University, Haematology Clinical Trials Unit, Cardiff (United Kingdom); Berthon, Beatrice; Marshall, Christopher [Wales Research and Diagnostic PET Imaging Centre, Cardiff (United Kingdom); Parkinson, Craig; Spezi, Emiliano [Cardiff University, School of Engineering, Cardiff (United Kingdom); Lewis, Wyn G. [University Hospital of Wales, Department of Upper GI Surgery, Cardiff (United Kingdom); Crosby, Tom D.L. [Department of Oncology, Velindre Cancer Centre, Cardiff (United Kingdom); Roberts, Stuart Ashley [University Hospital of Wales, Department of Clinical Radiology, Cardiff (United Kingdom)

    2018-01-15

    This retrospective cohort study developed a prognostic model incorporating PET texture analysis in patients with oesophageal cancer (OC). Internal validation of the model was performed. Consecutive OC patients (n = 403) were chronologically separated into development (n = 302, September 2010-September 2014, median age = 67.0, males = 227, adenocarcinomas = 237) and validation cohorts (n = 101, September 2014-July 2015, median age = 69.0, males = 78, adenocarcinomas = 79). Texture metrics were obtained using a machine-learning algorithm for automatic PET segmentation. A Cox regression model including age, radiological stage, treatment and 16 texture metrics was developed. Patients were stratified into quartiles according to a prognostic score derived from the model. A p-value < 0.05 was considered statistically significant. Primary outcome was overall survival (OS). Six variables were significantly and independently associated with OS: age [HR =1.02 (95% CI 1.01-1.04), p < 0.001], radiological stage [1.49 (1.20-1.84), p < 0.001], treatment [0.34 (0.24-0.47), p < 0.001], log(TLG) [5.74 (1.44-22.83), p = 0.013], log(Histogram Energy) [0.27 (0.10-0.74), p = 0.011] and Histogram Kurtosis [1.22 (1.04-1.44), p = 0.017]. The prognostic score demonstrated significant differences in OS between quartiles in both the development (X{sup 2} 143.14, df 3, p < 0.001) and validation cohorts (X{sup 2} 20.621, df 3, p < 0.001). This prognostic model can risk stratify patients and demonstrates the additional benefit of PET texture analysis in OC staging. (orig.)

  15. Assessment of Feasibility to Use Computer Aided Texture Analysis Based Tool for Parametric Images of Suspicious Lesions in DCE-MR Mammography

    Directory of Open Access Journals (Sweden)

    Mehmet Cemil Kale

    2013-01-01

    Full Text Available Our aim was to analyze the feasibility of computer aided malignant tumor detection using the traditional texture analysis applied on two-compartment-based parameter pseudoimages of dynamic contrast-enhanced magnetic resonance (DCE-MR breast image data. A major contribution of this research will be the through-plane assessment capability. Texture analysis was performed on two-compartment-based pseudo images of DCE-MRI datasets of breast data of eight subjects. The resulting texture parameter pseudo images were inputted to a feedforward neural network classification system which uses the manual segmentations of a primary radiologist as a gold standard, and each voxel was assigned as malignant or nonmalignant. The classification results were compared with the lesions manually segmented by a second radiologist. Results show that the mean true positive fraction (TPF and false positive fraction (FPF performance of the classifier vs. primary radiologist is statistically as good as the mean TPF and FPF performance of the second radiologist vs. primary radiologist with a confidence interval of 95% using a one-sample -test with . In the experiment implemented on all of the eight subjects, all malignant tumors marked by the primary radiologist were classified to be malignant by the computer classifier. Our results have shown that neural network classification using the textural parameters for automated screening of two-compartment-based parameter pseudo images of DCE-MRI as input data can be a supportive tool for the radiologists in the preassessment stage to show the possible cancerous regions and in the postassessment stage to review the segmentations especially in analyzing complex DCE-MRI cases.

  16. Textural analysis of early-phase spatiotemporal changes in contrast enhancement of breast lesions imaged with an ultrafast DCE-MRI protocol.

    Science.gov (United States)

    Milenković, Jana; Dalmış, Mehmet Ufuk; Žgajnar, Janez; Platel, Bram

    2017-09-01

    New ultrafast view-sharing sequences have enabled breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to be performed at high spatial and temporal resolution. The aim of this study is to evaluate the diagnostic potential of textural features that quantify the spatiotemporal changes of the contrast-agent uptake in computer-aided diagnosis of malignant and benign breast lesions imaged with high spatial and temporal resolution DCE-MRI. The proposed approach is based on the textural analysis quantifying the spatial variation of six dynamic features of the early-phase contrast-agent uptake of a lesion's largest cross-sectional area. The textural analysis is performed by means of the second-order gray-level co-occurrence matrix, gray-level run-length matrix and gray-level difference matrix. This yields 35 textural features to quantify the spatial variation of each of the six dynamic features, providing a feature set of 210 features in total. The proposed feature set is evaluated based on receiver operating characteristic (ROC) curve analysis in a cross-validation scheme for random forests (RF) and two support vector machine classifiers, with linear and radial basis function (RBF) kernel. Evaluation is done on a dataset with 154 breast lesions (83 malignant and 71 benign) and compared to a previous approach based on 3D morphological features and the average and standard deviation of the same dynamic features over the entire lesion volume as well as their average for the smaller region of the strongest uptake rate. The area under the ROC curve (AUC) obtained by the proposed approach with the RF classifier was 0.8997, which was significantly higher (P = 0.0198) than the performance achieved by the previous approach (AUC = 0.8704) on the same dataset. Similarly, the proposed approach obtained a significantly higher result for both SVM classifiers with RBF (P = 0.0096) and linear kernel (P = 0.0417) obtaining AUC of 0.8876 and 0.8548, respectively

  17. Preliminary study on the development of an antistretch marks water-in-oil cream: ultrasound assessment, texture analysis, and sensory analysis.

    Science.gov (United States)

    Bogdan, Cătălina; Moldovan, Mirela L; Man, Ioana Manuela; Crișan, Maria

    2016-01-01

    Striae distensae represent the result of the failure of the dermis to sustain intrinsic mechanical forces. Intensive moisturization of the lesions and use of emollient oils have been recommended for the prevention and treatment of striae distensae rubra. The aim of this research was to formulate an emollient water-in-oil cosmetic cream containing argan oil, which may be helpful in the prevention or early treatment of striae distensae. Sensory evaluation of the consistency, firmness, adhesiveness, oiliness, spreadability, and rapidity of penetration into the skin was evaluated by 22 volunteers using 10-point scales for each descriptor. The instrumental characterization of the cream was performed using Brookfield(®) CT3 Texture Analyzer. The cutaneous changes induced by the topical use of the cream were evaluated by assessing the thickness of the epidermis, hydration, and elasticity of the skin using DermaLab(®) Combo scanner. Ultrasound measurements showed an improvement in the elasticity of the epidermis following the application of cream. The product was well tolerated and appreciated by the consumers in terms of its spreadability, penetration ability, and lack of stickiness. The values recorded for texture analysis were firmness 10.16±0.15 mJ, adhesiveness 30.94±6.87 g, consistency 1229.50±119.78 g, spreadability 481.50±39 g, and stringiness 0.56±0.09 mJ. A water-in-oil cream containing argan oil and emollient ingredients with appropriate physical characteristics was obtained. In vivo study of clinical efficacy revealed a positive effect on increasing the skin elasticity, suggesting that the cream may be helpful in the prevention or early treatment of striae distensae.

  18. Differentiation between acute and chronic myocardial infarction by means of texture analysis of late gadolinium enhancement and cine cardiac magnetic resonance imaging.

    Science.gov (United States)

    Larroza, Andrés; Materka, Andrzej; López-Lereu, María P; Monmeneu, José V; Bodí, Vicente; Moratal, David

    2017-07-01

    The purpose of this study was to differentiate acute from chronic myocardial infarction using machine learning techniques and texture features extracted from cardiac magnetic resonance imaging (MRI). The study group comprised 22 cases with acute myocardial infarction (AMI) and 22 cases with chronic myocardial infarction (CMI). Cine and late gadolinium enhancement (LGE) MRI were analyzed independently to differentiate AMI from CMI. A total of 279 texture features were extracted from predefined regions of interest (ROIs): the infarcted area on LGE MRI, and the entire myocardium on cine MRI. Classification performance was evaluated by a nested cross-validation approach combining a feature selection technique with three predictive models: random forest, support vector machine (SVM) with Gaussian Kernel, and SVM with polynomial kernel. The polynomial SVM yielded the best classification performance. Receiver operating characteristic curves provided area-under-the-curve (AUC) (mean±standard deviation) of 0.86±0.06 on LGE MRI using 72 features; AMI sensitivity=0.81±0.08 and specificity=0.84±0.09. On cine MRI, AUC=0.82±0.06 using 75 features; AMI sensitivity=0.79±0.10 and specificity=0.80±0.10. We concluded that texture analysis can be used for differentiation of AMI from CMI on cardiac LGE MRI, and also on standard cine sequences in which the infarction is visually imperceptible in most cases. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Pretreatment 18F-FDG PET Textural Features in Locally Advanced Non–Small Cell Lung Cancer: Secondary Analysis of ACRIN 6668/RTOG 0235

    Science.gov (United States)

    Ohri, Nitin; Duan, Fenghai; Snyder, Bradley S.; Wei, Bo; Machtay, Mitchell; Alavi, Abass; Siegel, Barry A.; Johnson, Douglas W.; Bradley, Jeffrey D.; DeNittis, Albert; Werner-Wasik, Maria; El Naqa, Issam

    2016-01-01

    In a secondary analysis of American College of Radiology Imaging Network (ACRIN) 6668/RTOG 0235, high pretreatment metabolic tumor volume (MTV) on 18F-FDG PET was found to be a poor prognostic factor for patients treated with chemoradiotherapy for locally advanced non–small cell lung cancer (NSCLC). Here we utilize the same dataset to explore whether heterogeneity metrics based on PET textural features can provide additional prognostic information. Methods Patients with locally advanced NSCLC underwent 18F-FDG PET prior to treatment. A gradient-based segmentation tool was used to contour each patient’s primary tumor. MTV, maximum SUV, and 43 textural features were extracted for each tumor. To address over-fitting and high collinearity among PET features, the least absolute shrinkage and selection operator (LASSO) method was applied to identify features that were independent predictors of overall survival (OS) after adjusting for MTV. Recursive binary partitioning in a conditional inference framework was utilized to identify optimal thresholds. Kaplan–Meier curves and log-rank testing were used to compare outcomes among patient groups. Results Two hundred one patients met inclusion criteria. The LASSO procedure identified 1 textural feature (SumMean) as an independent predictor of OS. The optimal cutpoint for MTV was 93.3 cm3, and the optimal Sum-Mean cutpoint for tumors above 93.3 cm3 was 0.018. This grouped patients into three categories: low tumor MTV (n = 155; median OS, 22.6 mo), high tumor MTV and high SumMean (n = 23; median OS, 20.0 mo), and high tumor MTV and low SumMean (n = 23; median OS, 6.2 mo; log-rank P textural PET features in the context of established prognostic factors. We have also identified a promising feature that may have prognostic value in locally advanced NSCLC patients with large tumors who are treated with chemoradiotherapy. Validation studies are warranted. PMID:26912429

  20. Haralick texture analysis of prostate MRI: utility for differentiating non-cancerous prostate from prostate cancer and differentiating prostate cancers with different Gleason scores

    Energy Technology Data Exchange (ETDEWEB)

    Wibmer, Andreas; Hricak, Hedvig; Sala, Evis; Vargas, Hebert Alberto [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York City, NY (United States); Gondo, Tatsuo; Matsumoto, Kazuhiro; Eastham, James [Memorial Sloan Kettering Cancer Center, Department of Urology, New York City, NY (United States); Veeraraghavan, Harini; Fehr, Duc [Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York City, NY (United States); Zheng, Junting; Goldman, Debra; Moskowitz, Chaya [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York City, NY (United States); Fine, Samson W.; Reuter, Victor E. [Memorial Sloan Kettering Cancer Center, Department of Pathology, New York City, NY (United States)

    2015-10-15

    To investigate Haralick texture analysis of prostate MRI for cancer detection and differentiating Gleason scores (GS). One hundred and forty-seven patients underwent T2- weighted (T2WI) and diffusion-weighted prostate MRI. Cancers ≥0.5 ml and non-cancerous peripheral (PZ) and transition (TZ) zone tissue were identified on T2WI and apparent diffusion coefficient (ADC) maps, using whole-mount pathology as reference. Texture features (Energy, Entropy, Correlation, Homogeneity, Inertia) were extracted and analysed using generalized estimating equations. PZ cancers (n = 143) showed higher Entropy and Inertia and lower Energy, Correlation and Homogeneity compared to non-cancerous tissue on T2WI and ADC maps (p-values: <.0001-0.008). In TZ cancers (n = 43) we observed significant differences for all five texture features on the ADC map (all p-values: <.0001) and for Correlation (p = 0.041) and Inertia (p = 0.001) on T2WI. On ADC maps, GS was associated with higher Entropy (GS 6 vs. 7: p = 0.0225; 6 vs. >7: p = 0.0069) and lower Energy (GS 6 vs. 7: p = 0.0116, 6 vs. >7: p = 0.0039). ADC map Energy (p = 0.0102) and Entropy (p = 0.0019) were significantly different in GS ≤3 + 4 versus ≥4 + 3 cancers; ADC map Entropy remained significant after controlling for the median ADC (p = 0.0291). Several Haralick-based texture features appear useful for prostate cancer detection and GS assessment. (orig.)

  1. Haralick texture analysis of prostate MRI: utility for differentiating non-cancerous prostate from prostate cancer and differentiating prostate cancers with different Gleason scores

    International Nuclear Information System (INIS)

    Wibmer, Andreas; Hricak, Hedvig; Sala, Evis; Vargas, Hebert Alberto; Gondo, Tatsuo; Matsumoto, Kazuhiro; Eastham, James; Veeraraghavan, Harini; Fehr, Duc; Zheng, Junting; Goldman, Debra; Moskowitz, Chaya; Fine, Samson W.; Reuter, Victor E.

    2015-01-01

    To investigate Haralick texture analysis of prostate MRI for cancer detection and differentiating Gleason scores (GS). One hundred and forty-seven patients underwent T2- weighted (T2WI) and diffusion-weighted prostate MRI. Cancers ≥0.5 ml and non-cancerous peripheral (PZ) and transition (TZ) zone tissue were identified on T2WI and apparent diffusion coefficient (ADC) maps, using whole-mount pathology as reference. Texture features (Energy, Entropy, Correlation, Homogeneity, Inertia) were extracted and analysed using generalized estimating equations. PZ cancers (n = 143) showed higher Entropy and Inertia and lower Energy, Correlation and Homogeneity compared to non-cancerous tissue on T2WI and ADC maps (p-values: <.0001-0.008). In TZ cancers (n = 43) we observed significant differences for all five texture features on the ADC map (all p-values: <.0001) and for Correlation (p = 0.041) and Inertia (p = 0.001) on T2WI. On ADC maps, GS was associated with higher Entropy (GS 6 vs. 7: p = 0.0225; 6 vs. >7: p = 0.0069) and lower Energy (GS 6 vs. 7: p = 0.0116, 6 vs. >7: p = 0.0039). ADC map Energy (p = 0.0102) and Entropy (p = 0.0019) were significantly different in GS ≤3 + 4 versus ≥4 + 3 cancers; ADC map Entropy remained significant after controlling for the median ADC (p = 0.0291). Several Haralick-based texture features appear useful for prostate cancer detection and GS assessment. (orig.)

  2. BREAD CRUMBS TEXTURE OF SPELT

    Directory of Open Access Journals (Sweden)

    Joanna Korczyk – Szabó

    2014-02-01

    Full Text Available Texture analysis is an objective physical examination of baked products and gives direct information on the product quality, oppositely to dough rheology tests what inform on the baking suitability of the flour, as raw material. Evaluation of the mechanical properties of bread crumb is important not only for quality assurance in the bakeries, but also for assessing the effects of changes in dough ingredients and processing condition and also for describing the changes in bread crumb during storage. Crumb cellular structure is an important quality criterion used in commercial baking and research laboratories to judge bread quality alongside taste, crumb colour and crumb physical texture. In the framework of our research during the years 2010 – 2011 were analyzed selected indicators of bread crumb for texture quality of three Triticum spelta L. cultivars – Altgold, Rubiota and Ostro grown in an ecological system. The bread texture quality was evaluated on texture analyzer TA.XT Plus (Stable Micro Systems, Surrey, UK, following the AACC (74-09 standard and expressed as crumb firmness (N, stiffness (N.mm-1 and relative elasticity (%. Our research proved that all selected indicators were significantly influenced by the year of growing and variety. The most soft bread was achieved in Rubiota, whereas bread crumb samples from Altgold and Ostro were the most firm and stiff. Correlation analysis showed strong negative correlation between relative elasticity and bread crumb firmness as well as bread stiffness (-0.65++, -0.66++. The spelt wheat bread crumb texture need further investigation as it can be a reliable quality parameter.

  3. MR textural analysis on T2 FLAIR images for the prediction of true oligodendroglioma by the 2016 WHO genetic classification.

    Science.gov (United States)

    Rui, Wenting; Ren, Yan; Wang, Yin; Gao, Xinyi; Xu, Xiao; Yao, Zhenwei

    2017-11-15

    The genetic status of 1p/19q is important for differentiating oligodendroglioma, isocitrate-dehydrogenase (IDH)-mutant, and 1p/19q-codeleted from diffuse astrocytoma, IDH-mutant according to the 2016 World Health Organization (WHO) criteria. To assess the value of magnetic resonance textural analysis (MRTA) on T 2 fluid-attenuated inversion recovery (FLAIR) images for making a genetically integrated diagnosis of true oligodendroglioma by WHO guidelines. Retrospective case control. In all, there were 54 patients with a histopathological diagnosis of diffuse glioma (grade II). All were tested for IDH and 1p/19q. 3.0T, including T 2 FLAIR sequence, axial T 1 -weighted, and T 2 -weighted sequence. MRTA on a representative tumor region of interest (ROI) was made on preoperative T 2 FLAIR images around the area that had the largest diameter of solid tumor using Omni Kinetics software. Differences between IDH-mutant and 1p/19q-codeleted and IDH-mutant and 1p/19q-intact gliomas were analyzed by the Mann-Whitney rank sum test. Receiver operating characteristic curves (ROC) were created to assess MRTA diagnostic performance. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated with a cutoff value according to the Youden Index. Comparisons demonstrated significant differences in kurtosis (P = 0.007), energy (0.008), entropy (0.008), mean deviation (MD) (features comprising entropy (area under the curve [AUC] = 0.718, sensitivity = 97.1%) and energy (0.719, 94.1%) had the highest sensitivity but lower specificity (both 45%). Second-order features such as HGLRE (AUC = 0.750, sensitivity = 73.5%, specificity = 80.0%) and sum average (0.751, 70.6%, 80.0%) had relatively higher specificity, and all had AUC >0.7. MD had the highest diagnostic performance, with AUC = 0.878, sensitivity = 94.1%, specificity = 75.0%, PPV = 86.5%, and NPV = 88.2%. MRTA on T 2 FLAIR images may be

  4. Intratumor partitioning and texture analysis of dynamic contrast-enhanced (DCE)-MRI identifies relevant tumor subregions to predict pathological response of breast cancer to neoadjuvant chemotherapy.

    Science.gov (United States)

    Wu, Jia; Gong, Guanghua; Cui, Yi; Li, Ruijiang

    2016-11-01

    To predict pathological response of breast cancer to neoadjuvant chemotherapy (NAC) based on quantitative, multiregion analysis of dynamic contrast enhancement magnetic resonance imaging (DCE-MRI). In this Institutional Review Board-approved study, 35 patients diagnosed with stage II/III breast cancer were retrospectively investigated using 3T DCE-MR images acquired before and after the first cycle of NAC. First, principal component analysis (PCA) was used to reduce the dimensionality of the DCE-MRI data with high temporal resolution. We then partitioned the whole tumor into multiple subregions using k-means clustering based on the PCA-defined eigenmaps. Within each tumor subregion, we extracted four quantitative Haralick texture features based on the gray-level co-occurrence matrix (GLCM). The change in texture features in each tumor subregion between pre- and during-NAC was used to predict pathological complete response after NAC. Three tumor subregions were identified through clustering, each with distinct enhancement characteristics. In univariate analysis, all imaging predictors except one extracted from the tumor subregion associated with fast washout were statistically significant (P < 0.05) after correcting for multiple testing, with area under the receiver operating characteristic (ROC) curve (AUC) or AUCs between 0.75 and 0.80. In multivariate analysis, the proposed imaging predictors achieved an AUC of 0.79 (P = 0.002) in leave-one-out cross-validation. This improved upon conventional imaging predictors such as tumor volume (AUC = 0.53) and texture features based on whole-tumor analysis (AUC = 0.65). The heterogeneity of the tumor subregion associated with fast washout on DCE-MRI predicted pathological response to NAC in breast cancer. J. Magn. Reson. Imaging 2016;44:1107-1115. © 2016 International Society for Magnetic Resonance in Medicine.

  5. On-line transmission electron microscopic image analysis of chromatin texture for differentiation of thyroid gland tumors.

    Science.gov (United States)

    Kriete, A; Schäffer, R; Harms, H; Aus, H M

    1987-06-01

    Nuclei of the cells from the thyroid gland were analyzed in a transmission electron microscope by direct TV scanning and on-line image processing. The method uses the advantages of a visual-perception model to detect structures in noisy and low-contrast images. The features analyzed include area, a form factor and texture parameters from the second derivative stage. Three tumor-free thyroid tissues, three follicular adenomas, three follicular carcinomas and three papillary carcinomas were studied. The computer-aided cytophotometric method showed that the most significant differences were the statistics of the chromatin texture features of homogeneity and regularity. These findings document the possibility of an automated differentiation of tumors at the ultrastructural level.

  6. Response evaluation of giant-cell tumor of bone treated by denosumab: Histogram and texture analysis of CT images.

    Science.gov (United States)

    Yi, Jisook; Lee, Young Han; Kim, Sang Kyum; Kim, Seung Hyun; Song, Ho-Taek; Shin, Kyoo-Ho; Suh, Jin-Suck

    2018-05-01

    This study aimed to compare computed tomography (CT) features, including tumor size and textural and histogram measurements, of giant-cell tumors of bone (GCTBs) before and after denosumab treatment and determine their applicability in monitoring GCTB response to denosumab treatment. This retrospective study included eight patients (male, 3; female, 5; mean age, 33.4 years) diagnosed with GCTB, who had received treatment by denosumab and had undergone pre- and post-treatment non-contrast CT between January 2010 and December 2016. This study was approved by the institutional review board. Pre- and post-treatment size, histogram, and textural parameters of GCTBs were compared by the Wilcoxon signed-rank test. Pathological findings of five patients who underwent surgery after denosumab treatment were evaluated for assessment of treatment response. Relative to the baseline values, the tumor size had decreased, while the mean attenuation, standard deviation, entropy (all, P = 0.017), and skewness (P = 0.036) of the GCTBs had significantly increased post-treatment. Although the difference was statistically insignificant, the tumors also exhibited increased kurtosis, contrast, and inverse difference moment (P = 0.123, 0.327, and 0.575, respectively) post-treatment. Histologic findings revealed new bone formation and complete depletion or decrease in the number of osteoclast-like giant cells. The histogram and textural parameters of GCTBs changed significantly after denosumab treatment. Knowledge of the tendency towards increased mean attenuation and heterogeneity but increased local homogeneity in post-treatment CT histogram and textural features of GCTBs might aid in treatment planning and tumor response evaluation during denosumab treatment. Copyright © 2018. Published by Elsevier B.V.

  7. Shape and texture analysis of the carotid plaque, and its correlation with cerebral infarctions on CT, and cerebrovascular symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Kalomiris, Konstantinos; Tegos, Thomas J; Sabetai, Michael; Nicolaides, Andrew N [Irvine Laboratory for Cardiovascular Investigations and Research, Imperial College School of Medicine at St Mary` , Praed Street, London W2 1NY (United Kingdom)

    1999-12-31

    This work has studied the relationship between ultrasonic texture characteristics, ultrasonic shape characteristics, cerebral infarctions on CT, and cerebrovascular symptoms, in an attempt to identify the unstable carotid plaque, i.e. the plaque associated with high prevalence of ipsilateral cerebral infarctions on CT, and cerebrovascular symptoms. The morphological features used were : the grey scale median (GSM) for the texture, and the bending energy (BE) for the shape. It has been shown that echoluscent plaques (plaques with low GSM) with irregular shape (high BE) are associated with high prevalence of ipsilateral cerebral infarctions on CT and cerebrovascular symptoms, whereas echogenic plaques (high GSM) with smooth shape (low BE) are associated with low prevalence of ipsilateral cerebral infarctions on CT and cerebrovascular symptoms. Previous work has demonstrated the significance of the GSM in identifying the unstable carotid plaques, but no attempt, to our knowledge, has been made to establish the clinical significance of the ultrasonic shape characteristics of the carotid plaque. The importance of the ultrasonic texture and shape characteristics will be established in prospective studies of patients with asymptomatic carotid plaques, aiming at the identification of patients with a high risk for stroke, and therefore for a better selection of asymptomatic patients who might benefit from a carotid endarterectomy. (authors) 5 refs., 3 figs.

  8. Using Image Texture and Spectral Reflectance Analysis to Detect Yellowness and Esca in Grapevines at Leaf-Level

    Directory of Open Access Journals (Sweden)

    Hania Al-Saddik

    2018-04-01

    Full Text Available Plant diseases are one of the main reasons behind major economic and production losses in the agricultural field. Current research activities enable large fields monitoring and plant disease detection using innovative and robust technologies. French grapevines have a reputation for producing premium quality wines, however, these major fruit crops are susceptible to many diseases, including Esca, Downy mildew, Powdery mildew, Yellowing, and many others. In this study, we focused on two main infections (Esca and Yellowing, and data were gathered from fields that were located in Aquitaine and Burgundy regions, France. Since plant diseases can be diagnosed from the properties of the leaf, we acquired both Red-Green-Blue (RGB digital image and hyperspectral reflectance data from infected and healthy leaves. Biophysical parameters that were produced by the PROSPECT model inversion together with texture parameters compiled from the literature were deduced. Then we investigated their relationship to damage caused by Yellowing and Esca. This study examined whether spectral and textural data can identify the two diseases through the use of Neural Networks. We obtained an overall accuracy of 99% for both of the diseases when textural and spectral data are combined. These results suggest that, first, biophysical parameters present a valid dimension reduction tool that could replace the use of complete hyperspectral data. Second, remote sensing using spectral reflectance and digital images can make an overall nondestructive, rapid, cost-effective, and reproducible technique to determine diseases in grapevines with a good level of accuracy.

  9. Scenario development and analysis in JNC'S second progress report

    International Nuclear Information System (INIS)

    Umeki, H.; Makino, H.; Miyahara, K.; Naito, M.

    2001-01-01

    Scenario development and analysis is an integral part of the performance assessment in the JNC's second progress report which will be issued by the end of November 1999. A systematic approach has been elaborated to ensure traceability and transparency in overall context of the scenario development and set up of calculation cases for assessment of the repository performance. In this approach, the hierarchical FEP matrix was designed to flexibly identify FEPs at different level of detail. The reasoned argument with clearly defined criteria was then applied for screening and grouping of FEPs to define scenarios in the form of influence diagrams. Scenarios and calculation cases were developed based on the expected safety functions of disposal system and relationships with potential detrimental/favorable factors and perturbation factors. The process to develop scenarios and calculation cases are recorded and managed in a computer system. (authors)

  10. Progressive Damage and Failure Analysis of Composite Laminates

    Science.gov (United States)

    Joseph, Ashith P. K.

    Composite materials are widely used in various industries for making structural parts due to higher strength to weight ratio, better fatigue life, corrosion resistance and material property tailorability. To fully exploit the capability of composites, it is required to know the load carrying capacity of the parts made of them. Unlike metals, composites are orthotropic in nature and fails in a complex manner under various loading conditions which makes it a hard problem to analyze. Lack of reliable and efficient failure analysis tools for composites have led industries to rely more on coupon and component level testing to estimate the design space. Due to the complex failure mechanisms, composite materials require a very large number of coupon level tests to fully characterize the behavior. This makes the entire testing process very time consuming and costly. The alternative is to use virtual testing tools which can predict the complex failure mechanisms accurately. This reduces the cost only to it's associated computational expenses making significant savings. Some of the most desired features in a virtual testing tool are - (1) Accurate representation of failure mechanism: Failure progression predicted by the virtual tool must be same as those observed in experiments. A tool has to be assessed based on the mechanisms it can capture. (2) Computational efficiency: The greatest advantages of a virtual tools are the savings in time and money and hence computational efficiency is one of the most needed features. (3) Applicability to a wide range of problems: Structural parts are subjected to a variety of loading conditions including static, dynamic and fatigue conditions. A good virtual testing tool should be able to make good predictions for all these different loading conditions. The aim of this PhD thesis is to develop a computational tool which can model the progressive failure of composite laminates under different quasi-static loading conditions. The analysis

  11. DCE-MRI texture analysis with tumor subregion partitioning for predicting Ki-67 status of estrogen receptor-positive breast cancers

    KAUST Repository

    Fan, Ming

    2017-12-08

    Breast tumor heterogeneity is related to risk factors that lead to worse prognosis, yet such heterogeneity has not been well studied.To predict the Ki-67 status of estrogen receptor (ER)-positive breast cancer patients via analysis of tumor heterogeneity with subgroup identification based on patterns of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).Retrospective study.Seventy-seven breast cancer patients with ER-positive breast cancer were investigated, of whom 51 had low Ki-67 expression.T1 -weighted 3.0T DCE-MR images.Each tumor was partitioned into multiple subregions using three methods based on patterns of dynamic enhancement: 1) time to peak (TTP), 2) peak enhancement rate (PER), and 3) kinetic pattern clustering (KPC). In each tumor subregion, 18 texture features were computed.Univariate and multivariate logistic regression analyses were performed using a leave-one-out-based cross-validation (LOOCV) method. The partitioning results were compared with the same feature extraction methods across the whole tumor.In the univariate analysis, the best-performing feature was the texture statistic of sum variance in the tumor subregion with early TTP for differentiating between patients with high and low Ki-67 expression (area under the receiver operating characteristic curves, AUC = 0.748). Multivariate analysis showed that features from the tumor subregion associated with early TTP yielded the highest performance (AUC = 0.807) among the subregions for predicting the Ki-67 status. Among all regions, the tumor area with high PER at a precontrast MR image achieved the highest performance (AUC = 0.722), while the subregion that exhibited the highest overall enhancement rate based on KPC had an AUC of 0.731. These three models based on intratumoral texture analysis significantly (P < 0.01) outperformed the model using features from the whole tumor (AUC = 0.59).Texture analysis of intratumoral heterogeneity has the potential to serve as a valuable

  12. Dilatometry study of textures

    International Nuclear Information System (INIS)

    Sofrenovic, R.; Lazarevic, Dj.

    1965-01-01

    Presence of textures in the metal uranium fuel is harmful because of anisotropy properties of uranium during thermal treatment, and especially during irradiation. Anisotropic radiation swelling of uranium can cause deformation of fuel element due to existence of textures. The objective of this work was studying of the influence of phase transformations on textures in uranium which has undergone plastic deformation due to rotational casting. Dilatometry method was adopted for testing the textures. This report describes the device for dilatometry testing and the measured preliminary results are shown

  13. SU-F-R-13: Decoding 18F-FDG Uptake Heterogeneity for Primary and Lymphoma Tumors by Using Texture Analysis in PET Images

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Yin, Y [Shandong Cancer Hospital and Institute, Jinan, Shandong (China)

    2016-06-15

    Purpose: To explore 18F-FDG uptake heterogeneity of primary tumor and lymphoma tumor by texture features of PET image and quantify the heterogeneity difference between primary tumor and lymphoma tumor. Methods: 18 patients with primary tumor and lymphoma tumor in lung cancer were enrolled. All patients underwent whole-body 18F-FDG PET/CT scans before treatment. Texture features, based on Gray-level Co-occurrence Matrix, second and high order matrices are extracted from code using MATLAB software to quantify 18F-FDG uptake heterogeneity. The relationships of volume between energy, entropy, correlation, homogeneity and contrast were analyzed. Results: For different cases, tumor heterogeneity was not the same. Texture parameters (contrast, entropy, and correlation) of lymphoma were lower than primary tumor. On the contrast, the texture parameters (energy, homogeneity and inverse different moment) of lymphoma were higher than primary tumor. Significantly, correlations were observed between volume and energy (primary, r=−0.194, p=0.441; lymphoma, r=−0.339, p=0.582), homogeneity (primary, r=−0.146, p=0.382; lymphoma, r=−0.193, p=0.44), inverse difference moment (primary, r=−0.14, p=0.374; lymphoma, r=−0.172, p=0.414) and a positive correlation between volume and entropy (primary, r=0.233, p=0.483; lymphoma, r=0.462, p=0.680), contrast (primary, r=0.159, p=0.399; lymphoma, r=0.341, p=0.584), correlation (primary, r=0.027, p=0.165; lymphoma, r=0.046, p=0.215). For the same patient, energy for primary and lymphoma tumor is equal. The volume of lymphoma is smaller than primary tumor, but the homogeneity were higher than primary tumor. Conclusion: This study showed that there were effective heterogeneity differences between primary and lymphoma tumor by FDG-PET image texture analysis.

  14. SU-F-R-13: Decoding 18F-FDG Uptake Heterogeneity for Primary and Lymphoma Tumors by Using Texture Analysis in PET Images

    International Nuclear Information System (INIS)

    Ma, C; Yin, Y

    2016-01-01

    Purpose: To explore 18F-FDG uptake heterogeneity of primary tumor and lymphoma tumor by texture features of PET image and quantify the heterogeneity difference between primary tumor and lymphoma tumor. Methods: 18 patients with primary tumor and lymphoma tumor in lung cancer were enrolled. All patients underwent whole-body 18F-FDG PET/CT scans before treatment. Texture features, based on Gray-level Co-occurrence Matrix, second and high order matrices are extracted from code using MATLAB software to quantify 18F-FDG uptake heterogeneity. The relationships of volume between energy, entropy, correlation, homogeneity and contrast were analyzed. Results: For different cases, tumor heterogeneity was not the same. Texture parameters (contrast, entropy, and correlation) of lymphoma were lower than primary tumor. On the contrast, the texture parameters (energy, homogeneity and inverse different moment) of lymphoma were higher than primary tumor. Significantly, correlations were observed between volume and energy (primary, r=−0.194, p=0.441; lymphoma, r=−0.339, p=0.582), homogeneity (primary, r=−0.146, p=0.382; lymphoma, r=−0.193, p=0.44), inverse difference moment (primary, r=−0.14, p=0.374; lymphoma, r=−0.172, p=0.414) and a positive correlation between volume and entropy (primary, r=0.233, p=0.483; lymphoma, r=0.462, p=0.680), contrast (primary, r=0.159, p=0.399; lymphoma, r=0.341, p=0.584), correlation (primary, r=0.027, p=0.165; lymphoma, r=0.046, p=0.215). For the same patient, energy for primary and lymphoma tumor is equal. The volume of lymphoma is smaller than primary tumor, but the homogeneity were higher than primary tumor. Conclusion: This study showed that there were effective heterogeneity differences between primary and lymphoma tumor by FDG-PET image texture analysis.

  15. Prediction of Chemoresistance in Women Undergoing Neo-Adjuvant Chemotherapy for Locally Advanced Breast Cancer: Volumetric Analysis of First-Order Textural Features Extracted from Multiparametric MRI.

    Science.gov (United States)

    Panzeri, M M; Losio, C; Della Corte, A; Venturini, E; Ambrosi, A; Panizza, P; De Cobelli, F

    2018-01-01

    To assess correlations between volumetric first-order texture parameters on baseline MRI and pathological response after neoadjuvant chemotherapy (NAC) for locally advanced breast cancer (BC). 69 patients with locally advanced BC candidate to neoadjuvant chemotherapy underwent MRI within 4 weeks from the start of therapeutic regimen. T2, DWI, and DCE sequences were analyzed and maps were generated for Apparent Diffusion Coefficient (ADC), T2 signal intensity, and the following dynamic parameters: k -trans, peak enhancement, area under curve (AUC), time to maximal enhancement (TME), wash-in rate, and washout rate. Volumetric analysis of these parameters was performed, yielding a histogram analysis including first-order texture kinetics (percentiles, maximum value, minimum value, range, standard deviation, mean, median, mode, skewness, and kurtosis). Finally, correlations between these values and response to NAC (evaluated on the surgical specimen according to RECIST 1.1 criteria) were assessed. Out of 69 tumors, 33 (47.8%) achieved complete pathological response, 26 (37.7%) partial response, and 10 (14.5%) no response. Higher levels of AUCmax ( p value = 0.0338), AUCrange ( p value = 0.0311), and TME 75 ( p value = 0.0452) and lower levels of washout 10 ( p value = 0.0417), washout 20 ( p value = 0.0138), washout 25 ( p value = 0.0114), and washout 30 ( p value = 0.05) were predictive of noncomplete response. Histogram-derived texture analysis of MRI images allows finding quantitative parameters predictive of nonresponse to NAC in women affected by locally advanced BC.

  16. Prediction of Chemoresistance in Women Undergoing Neo-Adjuvant Chemotherapy for Locally Advanced Breast Cancer: Volumetric Analysis of First-Order Textural Features Extracted from Multiparametric MRI

    Directory of Open Access Journals (Sweden)

    M. M. Panzeri

    2018-01-01

    Full Text Available Purpose. To assess correlations between volumetric first-order texture parameters on baseline MRI and pathological response after neoadjuvant chemotherapy (NAC for locally advanced breast cancer (BC. Materials and Methods. 69 patients with locally advanced BC candidate to neoadjuvant chemotherapy underwent MRI within 4 weeks from the start of therapeutic regimen. T2, DWI, and DCE sequences were analyzed and maps were generated for Apparent Diffusion Coefficient (ADC, T2 signal intensity, and the following dynamic parameters: k-trans, peak enhancement, area under curve (AUC, time to maximal enhancement (TME, wash-in rate, and washout rate. Volumetric analysis of these parameters was performed, yielding a histogram analysis including first-order texture kinetics (percentiles, maximum value, minimum value, range, standard deviation, mean, median, mode, skewness, and kurtosis. Finally, correlations between these values and response to NAC (evaluated on the surgical specimen according to RECIST 1.1 criteria were assessed. Results. Out of 69 tumors, 33 (47.8% achieved complete pathological response, 26 (37.7% partial response, and 10 (14.5% no response. Higher levels of AUCmax (p value = 0.0338, AUCrange (p value = 0.0311, and TME75 (p value = 0.0452 and lower levels of washout10 (p value = 0.0417, washout20 (p value = 0.0138, washout25 (p value = 0.0114, and washout30 (p value = 0.05 were predictive of noncomplete response. Conclusion. Histogram-derived texture analysis of MRI images allows finding quantitative parameters predictive of nonresponse to NAC in women affected by locally advanced BC.

  17. Texture analysis with neutron bending on geological/mineralogical multi-phase samples using a locally resolving detector and profile analysis

    International Nuclear Information System (INIS)

    Merz, P.L.

    1991-02-01

    In the context of this work, the NANCY four circuit diffractometer of the University of Bonn at the RRJ2 research reactor at KFA Juelich was equipped with a linear locally resolving scintillation detector JULIOS. To evaluate the diffractogram occurring at a pole figure measurement, user-friendly profile analysis and other evaluation programs were developed on the PC. The course of evaluation was largely automated, so that only a few interactive steps are required. The measuring period of a sample is usually two to three days. Up to 35 pole figures are produced, depending on the phase conditions of the examined sample. The evaluation of up to 900 diffractograms with the aid of the automatically running profile analysis program takes between 30 and 100 minutes on a 20 MHz PC 386. Pole figure datafiles are produced from the intensity data obtained in this way by a conversion program. The texture analyses of copper pyrites ores introduced here are connected with geological questions. (orig.) [de

  18. A dynamical system approach to texel identification in regular textures

    NARCIS (Netherlands)

    Grigorescu, S.E.; Petkov, N.; Loncaric, S; Neri, A; Babic, H

    2003-01-01

    We propose a texture analysis method based on Rényi’s entropies. The method aims at identifying texels in regular textures by searching for the smallest window through which the minimum number of different visual patterns is observed when moving the window over a given texture. The experimental

  19. Texture Control During the Manufacturing of Nonoriented Electrical Steels

    NARCIS (Netherlands)

    Kestens, L.; Jacobs, S.

    2008-01-01

    Methods of modern quantitative texture analysis are applied in order to characterize the crystallographic texture of various non-oriented electrical steel grades in view of their relation with the magnetic properties of the steel sheet. A texture parameter is defined which quantifies the density of

  20. SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dengwang [Shandong Normal University, Jinan, Shandong Province (China); Wang, Qinfen [Shandong Normal University, Jinan, Shandong (China); Li, H; Chen, J [Shandong Cancer Hospital and Institute, Jinan, Shandong (China)

    2014-06-01

    Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity

  1. Dislocation density and Burgers vector population in fiber-textured Ni thin films determined by high-resolution X-ray line profile analysis

    DEFF Research Database (Denmark)

    Csiszár, Gábor; Pantleon, Karen; Alimadadi, Hossein

    2012-01-01

    distribution are determined by high-resolution X-ray diffraction line profile analysis. The substructure parameters are correlated with the strength of the films by using the combined Taylor and Hall-Petch relations. The convolutional multiple whole profile method is used to obtain the substructure parameters......Nanocrystalline Ni thin films have been produced by direct current electrodeposition with different additives and current density in order to obtain 〈100〉, 〈111〉 and 〈211〉 major fiber textures. The dislocation density, the Burgers vector population and the coherently scattering domain size...

  2. EVNTRE, Code System for Event Progression Analysis for PRA

    International Nuclear Information System (INIS)

    2002-01-01

    1 - Description of program or function: EVNTRE is a generalized event tree processor that was developed for use in probabilistic risk analysis of severe accident progressions for nuclear power plants. The general nature of EVNTRE makes it applicable to a wide variety of analyses that involve the investigation of a progression of events which lead to a large number of sets of conditions or scenarios. EVNTRE efficiently processes large, complex event trees. It can assign probabilities to event tree branch points in several different ways, classify pathways or outcomes into user-specified groupings, and sample input distributions of probabilities and parameters. PSTEVNT, a post-processor program used to sort and reclassify the 'binned' data output from EVNTRE and generate summary tables, is included. 2 - Methods: EVNTRE processes event trees that are cast in the form of questions or events, with multiple choice answers for each question. Split fractions (probabilities or frequencies that sum to unity) are either supplied or calculated for the branches of each question in a path-dependent manner. EVNTRE traverses the tree, enumerating the leaves of the tree and calculating their probabilities or frequencies based upon the initial probability or frequency and the split fractions for the branches taken along the corresponding path to an individual leaf. The questions in the event tree are usually grouped to address specific phases of time regimes in the progression of the scenario or severe accident. Grouping or binning of each path through the event tree in terms of a small number of characteristics or attributes is allowed. Boolean expressions of the branches taken are used to select the appropriate values of the characteristics of interest for the given path. Typically, the user specifies a cutoff tolerance for the frequency of a pathway to terminate further exploration. Multiple sets of input to an event tree can be processed by using Monte Carlo sampling to generate

  3. Investigating the use of texture features for analysis of breast lesions on contrast-enhanced cone beam CT

    Science.gov (United States)

    Wang, Xixi; Nagarajan, Mahesh B.; Conover, David; Ning, Ruola; O'Connell, Avice; Wismueller, Axel

    2014-04-01

    Cone beam computed tomography (CBCT) has found use in mammography for imaging the entire breast with sufficient spatial resolution at a radiation dose within the range of that of conventional mammography. Recently, enhancement of lesion tissue through the use of contrast agents has been proposed for cone beam CT. This study investigates whether the use of such contrast agents improves the ability of texture features to differentiate lesion texture from healthy tissue on CBCT in an automated manner. For this purpose, 9 lesions were annotated by an experienced radiologist on both regular and contrast-enhanced CBCT images using two-dimensional (2D) square ROIs. These lesions were then segmented, and each pixel within the lesion ROI was assigned a label - lesion or non-lesion, based on the segmentation mask. On both sets of CBCT images, four three-dimensional (3D) Minkowski Functionals were used to characterize the local topology at each pixel. The resulting feature vectors were then used in a machine learning task involving support vector regression with a linear kernel (SVRlin) to classify each pixel as belonging to the lesion or non-lesion region of the ROI. Classification performance was assessed using the area under the receiver-operating characteristic (ROC) curve (AUC). Minkowski Functionals derived from contrastenhanced CBCT images were found to exhibit significantly better performance at distinguishing between lesion and non-lesion areas within the ROI when compared to those extracted from CBCT images without contrast enhancement (p < 0.05). Thus, contrast enhancement in CBCT can improve the ability of texture features to distinguish lesions from surrounding healthy tissue.

  4. Normative values for CT-based texture analysis of vertebral bodies in dual X-ray absorptiometry-confirmed, normally mineralized subjects

    International Nuclear Information System (INIS)

    Mannil, Manoj; Eberhard, Matthias; Becker, Anton S.; Alkadhi, Hatem; Guggenberger, Roman; Schoenenberg, Denise; Osterhoff, Georg; Frey, Diana P.; Konukoglu, Ender

    2017-01-01

    To develop age-, gender-, and regional-specific normative values for texture analysis (TA) of spinal computed tomography (CT) in subjects with normal bone mineral density (BMD), as defined by dual X-ray absorptiometry (DXA), and to determine age-, gender-, and regional-specific differences. In this retrospective, IRB-approved study, TA was performed on sagittal CT bone images of the thoracic and lumbar spine using dedicated software (MaZda) in 141 individuals with normal DXA BMD findings. Numbers of female and male subjects were balanced in each of six age decades. Three hundred and five TA features were analyzed in thoracic and lumbar vertebrae using free-hand regions-of-interest. Intraclass correlation (ICC) coefficients were calculated for determining intra- and inter-observer agreement of each feature. Further dimension reduction was performed with correlation analyses. The TA features with an ICC 0.8 with other features were excluded from further analysis for dimension reduction. From the remaining 31 texture features, a significant correlation with age was found for the features mean (r = -0.489, p < 0.001), variance (r = -0.681, p < 0.001), kurtosis (r = 0.273, p < 0.001), and WavEnLL_s4 (r = 0.273, p < 0.001). Significant differences were found between genders for various higher-level texture features (p < 0.001). Regional differences among the thoracic spine, thoracic-lumbar junction, and lumbar spine were found for most TA features (p < 0.021). This study established normative values of TA features on CT images of the spine and showed age-, gender-, and regional-specific differences in individuals with normal BMD as defined by DXA. (orig.)

  5. Multi-institutional validation of a novel textural analysis tool for preoperative stratification of suspected thyroid tumors on diffusion-weighted MRI.

    Science.gov (United States)

    Brown, Anna M; Nagala, Sidhartha; McLean, Mary A; Lu, Yonggang; Scoffings, Daniel; Apte, Aditya; Gonen, Mithat; Stambuk, Hilda E; Shaha, Ashok R; Tuttle, R Michael; Deasy, Joseph O; Priest, Andrew N; Jani, Piyush; Shukla-Dave, Amita; Griffiths, John

    2016-04-01

    Ultrasound-guided fine needle aspirate cytology fails to diagnose many malignant thyroid nodules; consequently, patients may undergo diagnostic lobectomy. This study assessed whether textural analysis (TA) could noninvasively stratify thyroid nodules accurately using diffusion-weighted MRI (DW-MRI). This multi-institutional study examined 3T DW-MRI images obtained with spin echo echo planar imaging sequences. The training data set included 26 patients from Cambridge, United Kingdom, and the test data set included 18 thyroid cancer patients from Memorial Sloan Kettering Cancer Center (New York, New York, USA). Apparent diffusion coefficients (ADCs) were compared over regions of interest (ROIs) defined on thyroid nodules. TA, linear discriminant analysis (LDA), and feature reduction were performed using the 21 MaZda-generated texture parameters that best distinguished benign and malignant ROIs. Training data set mean ADC values were significantly different for benign and malignant nodules (P = 0.02) with a sensitivity and specificity of 70% and 63%, respectively, and a receiver operator characteristic (ROC) area under the curve (AUC) of 0.73. The LDA model of the top 21 textural features correctly classified 89/94 DW-MRI ROIs with 92% sensitivity, 96% specificity, and an AUC of 0.97. This algorithm correctly classified 16/18 (89%) patients in the independently obtained test set of thyroid DW-MRI scans. TA classifies thyroid nodules with high sensitivity and specificity on multi-institutional DW-MRI data sets. This method requires further validation in a larger prospective study. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  6. Normative values for CT-based texture analysis of vertebral bodies in dual X-ray absorptiometry-confirmed, normally mineralized subjects.

    Science.gov (United States)

    Mannil, Manoj; Eberhard, Matthias; Becker, Anton S; Schönenberg, Denise; Osterhoff, Georg; Frey, Diana P; Konukoglu, Ender; Alkadhi, Hatem; Guggenberger, Roman

    2017-11-01

    To develop age-, gender-, and regional-specific normative values for texture analysis (TA) of spinal computed tomography (CT) in subjects with normal bone mineral density (BMD), as defined by dual X-ray absorptiometry (DXA), and to determine age-, gender-, and regional-specific differences. In this retrospective, IRB-approved study, TA was performed on sagittal CT bone images of the thoracic and lumbar spine using dedicated software (MaZda) in 141 individuals with normal DXA BMD findings. Numbers of female and male subjects were balanced in each of six age decades. Three hundred and five TA features were analyzed in thoracic and lumbar vertebrae using free-hand regions-of-interest. Intraclass correlation (ICC) coefficients were calculated for determining intra- and inter-observer agreement of each feature. Further dimension reduction was performed with correlation analyses. The TA features with an ICC  0.8 with other features were excluded from further analysis for dimension reduction. From the remaining 31 texture features, a significant correlation with age was found for the features mean (r = -0.489, p < 0.001), variance (r = -0.681, p < 0.001), kurtosis (r = 0.273, p < 0.001), and WavEnLL_s4 (r = 0.273, p < 0.001). Significant differences were found between genders for various higher-level texture features (p < 0.001). Regional differences among the thoracic spine, thoracic-lumbar junction, and lumbar spine were found for most TA features (p < 0.021). This study established normative values of TA features on CT images of the spine and showed age-, gender-, and regional-specific differences in individuals with normal BMD as defined by DXA.

  7. Normative values for CT-based texture analysis of vertebral bodies in dual X-ray absorptiometry-confirmed, normally mineralized subjects

    Energy Technology Data Exchange (ETDEWEB)

    Mannil, Manoj; Eberhard, Matthias; Becker, Anton S.; Alkadhi, Hatem; Guggenberger, Roman [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Schoenenberg, Denise; Osterhoff, Georg [University Hospital Zurich, Division of Trauma Surgery, Zurich (Switzerland); Frey, Diana P. [University Hospital Zurich, Department of Rheumatology, Zurich (Switzerland); Konukoglu, Ender [Computer Vision Laboratory, Department of Information Technology and Electrical Engineering, Zurich (Switzerland)

    2017-11-15

    To develop age-, gender-, and regional-specific normative values for texture analysis (TA) of spinal computed tomography (CT) in subjects with normal bone mineral density (BMD), as defined by dual X-ray absorptiometry (DXA), and to determine age-, gender-, and regional-specific differences. In this retrospective, IRB-approved study, TA was performed on sagittal CT bone images of the thoracic and lumbar spine using dedicated software (MaZda) in 141 individuals with normal DXA BMD findings. Numbers of female and male subjects were balanced in each of six age decades. Three hundred and five TA features were analyzed in thoracic and lumbar vertebrae using free-hand regions-of-interest. Intraclass correlation (ICC) coefficients were calculated for determining intra- and inter-observer agreement of each feature. Further dimension reduction was performed with correlation analyses. The TA features with an ICC < 0.81 indicating compromised intra- and inter-observer agreement and with Pearson correlation scores r > 0.8 with other features were excluded from further analysis for dimension reduction. From the remaining 31 texture features, a significant correlation with age was found for the features mean (r = -0.489, p < 0.001), variance (r = -0.681, p < 0.001), kurtosis (r = 0.273, p < 0.001), and WavEnLL{sub s}4 (r = 0.273, p < 0.001). Significant differences were found between genders for various higher-level texture features (p < 0.001). Regional differences among the thoracic spine, thoracic-lumbar junction, and lumbar spine were found for most TA features (p < 0.021). This study established normative values of TA features on CT images of the spine and showed age-, gender-, and regional-specific differences in individuals with normal BMD as defined by DXA. (orig.)

  8. Influence of texture on the analysis of thermoelastic/plastic ansisotropy and the initial yielding of Zircaloy tubes

    International Nuclear Information System (INIS)

    Eisenberg, M.A.; Yen, C.F.

    1980-01-01

    Averaging procedures are developed to obtain texture factors relating the thermoelastic properties of single crystals of zirconium to polycrystalline properties. The effect of various approximations to the elastic properties of polycrystalline material and various assumed yield criteria on the transition from elastic to plastic behavior for a tube subjected to various boundary conditions is examined. It is found that thermal anisotropy has a greater effect on the elastic-plastic transitions than does elastic anisotropy. The choice of yield condition can also affect appreciably the predicted yielding behavior of a tube. (orig.)

  9. Mimicking human texture classification

    NARCIS (Netherlands)

    Rogowitz, B.E.; van Rikxoort, Eva M.; van den Broek, Egon; Pappas, T.N.; Schouten, Theo E.; Daly, S.J.

    2005-01-01

    In an attempt to mimic human (colorful) texture classification by a clustering algorithm three lines of research have been encountered, in which as test set 180 texture images (both their color and gray-scale equivalent) were drawn from the OuTex and VisTex databases. First, a k-means algorithm was

  10. Textured perovskite cells

    NARCIS (Netherlands)

    Deelen, J. van; Tezsevin, Y.; Barink, M.

    2017-01-01

    Most research of texturization of solar cells has been devoted to Si based cells. For perovskites, it was assumed that texturization would not have much of an impact because of the relatively low refractive indexes lead to relatively low reflection as compared to the Si based cells. However, our

  11. New durum wheat with soft kernel texture: milling performance and end-use quality analysis of the Hardness locus in Triticum turgidum ssp. durum

    Science.gov (United States)

    Wheat kernel texture dictates U.S. wheat market class. Durum wheat has limited demand and culinary end-uses compared to bread wheat because of its extremely hard kernel texture which preclude conventional milling. ‘Soft Svevo’, a new durum cultivar with soft kernel texture comparable to a soft white...

  12. New durum wheat with soft kernel texture: end-use quality analysis of the Hardness locus in Triticum turgidum ssp. durum

    Science.gov (United States)

    Wheat kernel texture dictates U.S. wheat market class. Durum wheat has limited demand and culinary end-uses compared to bread wheat because of its extremely hard kernel texture which precludes conventional milling. ‘Soft Svevo’, a new durum cultivar with soft kernel texture comparable to a soft whit...

  13. Preliminary study on the development of an antistretch marks water-in-oil cream: ultrasound assessment, texture analysis, and sensory analysis

    Directory of Open Access Journals (Sweden)

    Bogdan C

    2016-09-01

    Full Text Available Cătălina Bogdan,1 Mirela L Moldovan,1 Ioana Manuela Man,2 Maria Crișan,2 1Department of Dermopharmacy and Cosmetics, Faculty of Pharmacy, 2Department of Histology, Faculty of Medicine, University of Medicine and Pharmacy “Iuliu Hațieganu”, Cluj-Napoca, Romania Purpose: Striae distensae represent the result of the failure of the dermis to sustain intrinsic mechanical forces. Intensive moisturization of the lesions and use of emollient oils have been recommended for the prevention and treatment of striae distensae rubra. The aim of this research was to formulate an emollient water-in-oil cosmetic cream containing argan oil, which may be helpful in the prevention or early treatment of striae distensae. Patients and methods: Sensory evaluation of the consistency, firmness, adhesiveness, oiliness, spreadability, and rapidity of penetration into the skin was evaluated by 22 volunteers using 10-point scales for each descriptor. The instrumental characterization of the cream was performed using Brookfield® CT3 Texture Analyzer. The cutaneous changes induced by the topical use of the cream were evaluated by assessing the thickness of the epidermis, hydration, and elasticity of the skin using DermaLab® Combo scanner. Results: Ultrasound measurements showed an improvement in the elasticity of the epidermis following the application of cream. The product was well tolerated and appreciated by the consumers in terms of its spreadability, penetration ability, and lack of stickiness. The values recorded for texture analysis were firmness 10.16±0.15 mJ, adhesiveness 30.94±6.87 g, consistency 1229.50±119.78 g, spreadability 481.50±39 g, and stringiness 0.56±0.09 mJ. Conclusion: A water-in-oil cream containing argan oil and emollient ingredients with appropriate physical characteristics was obtained. In vivo study of clinical efficacy revealed a positive effect on increasing the skin elasticity, suggesting that the cream may be helpful in the

  14. Diffusion tensor analysis of corpus callosum in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Shoichi; Makino, Takahiro; Shirai, Wakako; Hattori, Takamichi [Department of Neurology, Graduate School of Medicine, Chiba University (Japan)

    2008-11-15

    Progressive supranuclear palsy (PSP) is a neurodegenerative disease featuring parkinsonism, supranuclear ophthalmoplegia, dysphagia, and frontal lobe dysfunction. The corpus callosum which consists of many commissure fibers probably reflects cerebral cortical function. Several previous reports showed atrophy or diffusion abnormalities of anterior corpus callosum in PSP patients, but partitioning method used in these studies was based on data obtained in nonhuman primates. In this study, we performed a diffusion tensor analysis using a new partitioning method for the human corpus callosum. Seven consecutive patients with PSP were compared with 29 age-matched patients with Parkinson's Disease (PD) and 19 age-matched healthy control subjects. All subjects underwent diffusion tensor magnetic resonance imaging, and the corpus callosum was partitioned into five areas on the mid-sagittal plane according to a recently established topography of human corpus callosum (CC1-prefrontal area, CC2-premotor and supplementary motor area, CC3-motor area, CC4-sensory area, CC5-parietal, temporal, and occipital area). Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were measured in each area and differences between groups were analyzed. In the PSP group, FA values were significantly decreased in CC1 and CC2, and ADC values were significantly increased in CC1 and CC2. Receiver operating characteristic analysis showed excellent reliability of FA and ADC analyses of CC1 for differentiating PSP from PD. The anterior corpus callosum corresponding to the prefrontal, premotor, and supplementary motor cortices is affected in PSP patients. This analysis can be an additional test for further confirmation of the diagnosis of PSP.

  15. Diffusion tensor analysis of corpus callosum in progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Ito, Shoichi; Makino, Takahiro; Shirai, Wakako; Hattori, Takamichi

    2008-01-01

    Progressive supranuclear palsy (PSP) is a neurodegenerative disease featuring parkinsonism, supranuclear ophthalmoplegia, dysphagia, and frontal lobe dysfunction. The corpus callosum which consists of many commissure fibers probably reflects cerebral cortical function. Several previous reports showed atrophy or diffusion abnormalities of anterior corpus callosum in PSP patients, but partitioning method used in these studies was based on data obtained in nonhuman primates. In this study, we performed a diffusion tensor analysis using a new partitioning method for the human corpus callosum. Seven consecutive patients with PSP were compared with 29 age-matched patients with Parkinson's Disease (PD) and 19 age-matched healthy control subjects. All subjects underwent diffusion tensor magnetic resonance imaging, and the corpus callosum was partitioned into five areas on the mid-sagittal plane according to a recently established topography of human corpus callosum (CC1-prefrontal area, CC2-premotor and supplementary motor area, CC3-motor area, CC4-sensory area, CC5-parietal, temporal, and occipital area). Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were measured in each area and differences between groups were analyzed. In the PSP group, FA values were significantly decreased in CC1 and CC2, and ADC values were significantly increased in CC1 and CC2. Receiver operating characteristic analysis showed excellent reliability of FA and ADC analyses of CC1 for differentiating PSP from PD. The anterior corpus callosum corresponding to the prefrontal, premotor, and supplementary motor cortices is affected in PSP patients. This analysis can be an additional test for further confirmation of the diagnosis of PSP

  16. Analysis of the right-handed Majorana neutrino mass in an S U (4 )×S U (2 )L×S U (2 )R Pati-Salam model with democratic texture

    Science.gov (United States)

    Yang, Masaki J. S.

    2017-03-01

    In this paper, we attempt to build a unified model with the democratic texture, that has some unification between up-type Yukawa interactions Yν and Yu . Since the S3 L×S3 R flavor symmetry is chiral, the unified gauge group is assumed to be Pati-Salam type S U (4 )c×S U (2 )L×S U (2 )R. The breaking scheme of the flavor symmetry is considered to be S3 L×S3 R→S2 L×S2 R→0 . In this picture, the four-zero texture is desirable for realistic masses and mixings. This texture is realized by a specific representation for the second breaking of the S3 L×S3 R flavor symmetry. Assuming only renormalizable Yukawa interactions, type-I seesaw mechanism, and neglecting C P phases for simplicity, the right-handed neutrino mass matrix MR can be reconstructed from low energy input values. Numerical analysis shows that the texture of MR basically behaves like the "waterfall texture." Since MR tends to be the "cascade texture" in the democratic texture approach, a model with type-I seesaw and up-type Yukawa unification Yν≃Yu basically requires fine-tunings between parameters. Therefore, it seems to be more realistic to consider universal waterfall textures for both Yf and MR, e.g., by the radiative mass generation or the Froggatt-Nielsen mechanism. Moreover, analysis of eigenvalues shows that the lightest mass eigenvalue MR 1 is too light to achieve successful thermal leptogenesis. Although the resonant leptogenesis might be possible, it also requires fine-tunings of parameters.

  17. Texture analysis of advanced non-small cell lung cancer (NSCLC) on contrast-enhanced computed tomography: prediction of the response to the first-line chemotherapy

    International Nuclear Information System (INIS)

    Farina, Davide; Morassi, Mauro; Maroldi, Roberto; Roca, Elisa; Tassi, Gianfranco; Cavalleri, Giuseppe

    2013-01-01

    To assess whether tumour heterogeneity, quantified by texture analysis (TA) on contrast-enhanced computed tomography (CECT), can predict response to chemotherapy in advanced non-small cell lung cancer (NSCLC). Fifty-three CECT studies of patients with advanced NSCLC who had undergone first-line chemotherapy were retrospectively reviewed. Response to chemotherapy was evaluated according to RECIST1.1. Tumour uniformity was assessed by a TA method based on Laplacian of Gaussian filtering. The resulting parameters were correlated with treatment response and overall survival by multivariate analysis. Thirty-one out of 53 patients were non-responders and 22 were responders. Average overall survival was 13 months (4-35), minimum follow-up was 12 months. In the adenocarcinoma group (n = 31), the product of tumour uniformity and grey level (GL*U) was the unique independent variable correlating with treatment response. Dividing the GL*U (range 8.5-46.6) into tertiles, lesions belonging to the second and the third tertiles had an 8.3-fold higher probability of treatment response compared with those in the first tertile. No association between texture features and response to treatment was observed in the non-adenocarcinoma group (n = 22). GL*U did not correlate with overall survival. TA on CECT images in advanced lung adenocarcinoma provides an independent predictive indicator of response to first-line chemotherapy. (orig.)

  18. Sensory and instrumental texture assessment of roasted pistachio nut/kernel by partial least square (PLS) regression analysis: effect of roasting conditions.

    Science.gov (United States)

    Mohammadi Moghaddam, Toktam; Razavi, Seyed M A; Taghizadeh, Masoud; Sazgarnia, Ameneh

    2016-01-01

    Roasting is an important step in the processing of pistachio nuts. The effect of hot air roasting temperature (90, 120 and 150 °C), time (20, 35 and 50 min) and air velocity (0.5, 1.5 and 2.5 m/s) on textural and sensory characteristics of pistachio nuts and kernels were investigated. The results showed that increasing the roasting temperature decreased the fracture force (82-25.54 N), instrumental hardness (82.76-37.59 N), apparent modulus of elasticity (47-21.22 N/s), compressive energy (280.73-101.18 N.s) and increased amount of bitterness (1-2.5) and the hardness score (6-8.40) of pistachio kernels. Higher roasting time improved the flavor of samples. The results of the consumer test showed that the roasted pistachio kernels have good acceptability for flavor (score 5.83-8.40), color (score 7.20-8.40) and hardness (score 6-8.40) acceptance. Moreover, Partial Least Square (PLS) analysis of instrumental and sensory data provided important information for the correlation of objective and subjective properties. The univariate analysis showed that over 93.87 % of the variation in sensory hardness and almost 87 % of the variation in sensory acceptability could be explained by instrumental texture properties.

  19. SU-F-J-207: Non-Small Cell Lung Cancer Patient Survival Prediction with Quantitative Tumor Textures Analysis in Baseline CT

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Y; Zou, J; Murillo, P; Nosher, J; Amorosa, J; Bramwit, M; Yue, N; Jabbour, S; Foran, D [Rutgers University, New Brunswick, NJ (United States)

    2016-06-15

    Purpose: Chemo-radiation therapy (CRT) is widely used in treating patients with locally advanced non-small cell lung cancer (NSCLC). Determination of the likelihood of patient response to treatment and optimization of treatment regime is of clinical significance. Up to date, no imaging biomarker has reliably correlated to NSCLC patient survival rate. This pilot study is to extract CT texture information from tumor regions for patient survival prediction. Methods: Thirteen patients with stage II-III NSCLC were treated using CRT with a median dose of 6210 cGy. Non-contrast-enhanced CT images were acquired for treatment planning and retrospectively collected for this study. Texture analysis was applied in segmented tumor regions using the Local Binary Pattern method (LBP). By comparing its HU with neighboring voxels, the LBPs of a voxel were measured in multiple scales with different group radiuses and numbers of neighbors. The LBP histograms formed a multi-dimensional texture vector for each patient, which was then used to establish and test a Support Vector Machine (SVM) model to predict patients’ one year survival. The leave-one-out cross validation strategy was used recursively to enlarge the training set and derive a reliable predictor. The predictions were compared with the true clinical outcomes. Results: A 10-dimensional LBP histogram was extracted from 3D segmented tumor region for each of the 13 patients. Using the SVM model with the leave-one-out strategy, only 1 out of 13 patients was misclassified. The experiments showed an accuracy of 93%, sensitivity of 100%, and specificity of 86%. Conclusion: Within the framework of a Support Vector Machine based model, the Local Binary Pattern method is able to extract a quantitative imaging biomarker in the prediction of NSCLC patient survival. More patients are to be included in the study.

  20. SU-F-J-207: Non-Small Cell Lung Cancer Patient Survival Prediction with Quantitative Tumor Textures Analysis in Baseline CT

    International Nuclear Information System (INIS)

    Wu, Y; Zou, J; Murillo, P; Nosher, J; Amorosa, J; Bramwit, M; Yue, N; Jabbour, S; Foran, D

    2016-01-01

    Purpose: Chemo-radiation therapy (CRT) is widely used in treating patients with locally advanced non-small cell lung cancer (NSCLC). Determination of the likelihood of patient response to treatment and optimization of treatment regime is of clinical significance. Up to date, no imaging biomarker has reliably correlated to NSCLC patient survival rate. This pilot study is to extract CT texture information from tumor regions for patient survival prediction. Methods: Thirteen patients with stage II-III NSCLC were treated using CRT with a median dose of 6210 cGy. Non-contrast-enhanced CT images were acquired for treatment planning and retrospectively collected for this study. Texture analysis was applied in segmented tumor regions using the Local Binary Pattern method (LBP). By comparing its HU with neighboring voxels, the LBPs of a voxel were measured in multiple scales with different group radiuses and numbers of neighbors. The LBP histograms formed a multi-dimensional texture vector for each patient, which was then used to establish and test a Support Vector Machine (SVM) model to predict patients’ one year survival. The leave-one-out cross validation strategy was used recursively to enlarge the training set and derive a reliable predictor. The predictions were compared with the true clinical outcomes. Results: A 10-dimensional LBP histogram was extracted from 3D segmented tumor region for each of the 13 patients. Using the SVM model with the leave-one-out strategy, only 1 out of 13 patients was misclassified. The experiments showed an accuracy of 93%, sensitivity of 100%, and specificity of 86%. Conclusion: Within the framework of a Support Vector Machine based model, the Local Binary Pattern method is able to extract a quantitative imaging biomarker in the prediction of NSCLC patient survival. More patients are to be included in the study.

  1. Effect of zooming on texture features of ultrasonic images

    Directory of Open Access Journals (Sweden)

    Kyriacou Efthyvoulos

    2006-01-01

    Full Text Available Abstract Background Unstable carotid plaques on subjective, visual, assessment using B-mode ultrasound scanning appear as echolucent and heterogeneous. Although previous studies on computer assisted plaque characterisation have standardised B-mode images for brightness, improving the objective assessment of echolucency, little progress has been made towards standardisation of texture analysis methods, which assess plaque heterogeneity. The aim of the present study was to investigate the influence of image zooming during ultrasound scanning on textural features and to test whether or not resolution standardisation decreases the variability introduced. Methods Eighteen still B-mode images of carotid plaques were zoomed during carotid scanning (zoom factor 1.3 and both images were transferred to a PC and normalised. Using bilinear and bicubic interpolation, the original images were interpolated in a process of simulating off-line zoom using the same interpolation factor. With the aid of the colour-coded image, carotid plaques of the original, zoomed and two resampled images for each case were outlined and histogram, first order and second order statistics were subsequently calculated. Results Most second order statistics (21/25, 84% were significantly (p Conclusion Texture analysis of ultrasonic plaques should be performed under standardised resolution settings; otherwise a resolution normalisation algorithm should be applied.

  2. Fast Image Texture Classification Using Decision Trees

    Science.gov (United States)

    Thompson, David R.

    2011-01-01

    Texture analysis would permit improved autonomous, onboard science data interpretation for adaptive navigation, sampling, and downlink decisions. These analyses would assist with terrain analysis and instrument placement in both macroscopic and microscopic image data products. Unfortunately, most state-of-the-art texture analysis demands computationally expensive convolutions of filters involving many floating-point operations. This makes them infeasible for radiation- hardened computers and spaceflight hardware. A new method approximates traditional texture classification of each image pixel with a fast decision-tree classifier. The classifier uses image features derived from simple filtering operations involving integer arithmetic. The texture analysis method is therefore amenable to implementation on FPGA (field-programmable gate array) hardware. Image features based on the "integral image" transform produce descriptive and efficient texture descriptors. Training the decision tree on a set of training data yields a classification scheme that produces reasonable approximations of optimal "texton" analysis at a fraction of the computational cost. A decision-tree learning algorithm employing the traditional k-means criterion of inter-cluster variance is used to learn tree structure from training data. The result is an efficient and accurate summary of surface morphology in images. This work is an evolutionary advance that unites several previous algorithms (k-means clustering, integral images, decision trees) and applies them to a new problem domain (morphology analysis for autonomous science during remote exploration). Advantages include order-of-magnitude improvements in runtime, feasibility for FPGA hardware, and significant improvements in texture classification accuracy.

  3. Pretreatment 18F-FDG PET Textural Features in Locally Advanced Non-Small Cell Lung Cancer: Secondary Analysis of ACRIN 6668/RTOG 0235.

    Science.gov (United States)

    Ohri, Nitin; Duan, Fenghai; Snyder, Bradley S; Wei, Bo; Machtay, Mitchell; Alavi, Abass; Siegel, Barry A; Johnson, Douglas W; Bradley, Jeffrey D; DeNittis, Albert; Werner-Wasik, Maria; El Naqa, Issam

    2016-06-01

    In a secondary analysis of American College of Radiology Imaging Network (ACRIN) 6668/RTOG 0235, high pretreatment metabolic tumor volume (MTV) on (18)F-FDG PET was found to be a poor prognostic factor for patients treated with chemoradiotherapy for locally advanced non-small cell lung cancer (NSCLC). Here we utilize the same dataset to explore whether heterogeneity metrics based on PET textural features can provide additional prognostic information. Patients with locally advanced NSCLC underwent (18)F-FDG PET prior to treatment. A gradient-based segmentation tool was used to contour each patient's primary tumor. MTV, maximum SUV, and 43 textural features were extracted for each tumor. To address overfitting and high collinearity among PET features, the least absolute shrinkage and selection operator (LASSO) method was applied to identify features that were independent predictors of overall survival (OS) after adjusting for MTV. Recursive binary partitioning in a conditional inference framework was utilized to identify optimal thresholds. Kaplan-Meier curves and log-rank testing were used to compare outcomes among patient groups. Two hundred one patients met inclusion criteria. The LASSO procedure identified 1 textural feature (SumMean) as an independent predictor of OS. The optimal cutpoint for MTV was 93.3 cm(3), and the optimal SumMean cutpoint for tumors above 93.3 cm(3) was 0.018. This grouped patients into three categories: low tumor MTV (n = 155; median OS, 22.6 mo), high tumor MTV and high SumMean (n = 23; median OS, 20.0 mo), and high tumor MTV and low SumMean (n = 23; median OS, 6.2 mo; log-rank P textural PET features in the context of established prognostic factors. We have also identified a promising feature that may have prognostic value in locally advanced NSCLC patients with large tumors who are treated with chemoradiotherapy. Validation studies are warranted. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  4. A procedure for the evaluation of 2D radiographic texture analysis to assess 3D bone micro-architecture; Evaluation de l'analyse de la texture de radiographies 2D pour evaluer les micro architecture 3D d'os

    Energy Technology Data Exchange (ETDEWEB)

    Apostol, L.; Peyrin, F.; Yot, S.; Basset, O.; Odet, Ch. [CREATIS - Centre National de la Recherche Scientifique (UMR CNRS 5515), 69 - Villeurbanne (France); Apostal, L.; Boller, E. [European Synchrotron Radiation Facility (ESRF), 38 - Grenoble (France); Tabary, J.; Dinten, J.M. [CEA Grenoble, Lab. d' Electronique et de Technologie de l' Informatique (LETI), 38 (France); Boudousq, V.; Kotzki, P.O. [Faculte de Medecine, Lab. de Biophysique Medicale, 30 - Nimes (France)

    2004-07-01

    Although the diagnosis of osteoporosis is mainly based on Dual X-ray Absorptiometry, it has been shown that trabecular bone micro-architecture is also an important factor in regards of fracture risk, which can be efficiently assessed in vitro using three-dimensional x-ray microtomography ({mu}CT). In vivo, techniques based on high-resolution x-ray radiography associated to texture analysis have been proposed to investigate bone micro-architecture, but their relevance for giving pertinent 3D information is unclear. The purpose of this work was to develop a method for evaluating the relationships between 3D micro-architecture and 2D texture parameters, and optimizing the conditions for radiographic imaging. Bone sample images taken from cortical to cortical were acquired using 3D-synchrotron x-ray {mu}CT at the ESRF. The 3D digital images were further used for two purposes: 1) quantification of three-dimensional bone micro-architecture, 2) simulation of realistic x-ray radiographs under different acquisition conditions. Texture analysis was then applied to these 2D radiographs using a large variety of methods (co-occurrence, spectrum, fractal...). First results of the statistical analysis between 2D and 3D parameters allowed identifying the most relevant 2D texture parameters. (authors)

  5. A Portfolio Analysis Tool for Measuring NASAs Aeronautics Research Progress toward Planned Strategic Outcomes

    Science.gov (United States)

    Tahmasebi, Farhad; Pearce, Robert

    2016-01-01

    Description of a tool for portfolio analysis of NASA's Aeronautics research progress toward planned community strategic Outcomes is presented. The strategic planning process for determining the community Outcomes is also briefly described. Stakeholder buy-in, partnership performance, progress of supporting Technical Challenges, and enablement forecast are used as the criteria for evaluating progress toward Outcomes. A few illustrative examples are also presented.

  6. Seismic texture and amplitude analysis of large scale fluid escape pipes using time lapses seismic surveys: examples from the Loyal Field (Scotland, UK)

    Science.gov (United States)

    Maestrelli, Daniele; Jihad, Ali; Iacopini, David; Bond, Clare

    2016-04-01

    Fluid escape pipes are key features of primary interest for the analysis of vertical fluid flow and secondary hydrocarbon migration in sedimentary basin. Identified worldwide (Løset et al., 2009), they acquired more and more importance as they represent critical pathways for supply of methane and potential structure for leakage into the storage reservoir (Cartwright & Santamarina, 2015). Therefore, understanding their genesis, internal characteristics and seismic expression, is of great significance for the exploration industry. Here we propose a detailed characterization of the internal seismic texture of some seal bypass system (e.g fluid escape pipes) from a 4D seismic survey (released by the BP) recently acquired in the Loyal Field. The seal by pass structure are characterized by big-scale fluid escape pipes affecting the Upper Paleogene/Neogene stratigraphic succession in the Loyal Field, Scotland (UK). The Loyal field, is located on the edge of the Faroe-Shetland Channel slope, about 130 km west of Shetland (Quadrants 204/205 of the UKCS) and has been recently re-appraised and re developed by a consortium led by BP. The 3D detailed mapping analysis of the full and partial stack survey (processed using amplitude preservation workflows) shows a complex system of fluid pipe structure rooted in the pre Lista formation and developed across the paleogene and Neogene Units. Geometrical analysis show that pipes got diameter varying between 100-300 m and a length of 500 m to 2 km. Most pipes seem to terminate abruptly at discrete subsurface horizons or in diffuse termination suggesting multiple overpressured events and lateral fluid migration (through Darcy flows) across the overburden units. The internal texture analysis of the large pipes, (across both the root and main conduit zones), using near, medium and far offset stack dataset (processed through an amplitude preserved PSTM workflow) shows a tendency of up-bending of reflection (rather than pulls up artefacts

  7. CT-based texture analysis potentially provides prognostic information complementary to interim fdg-pet for patients with hodgkin's and aggressive non-hodgkin's lymphomas

    Energy Technology Data Exchange (ETDEWEB)

    Ganeshan, B.; Miles, K.A.; Shortman, R.; Afaq, A.; Ardeshna, K.M.; Groves, A.M.; Kayani, I. [University College London, Institute of Nuclear Medicine, London (United Kingdom); Babikir, S. [International Atomic Energy Agency (IAEA), Human Health Division, Nuclear Medicine and Diagnostic Imaging Section, Vienna (Austria)

    2017-03-15

    The purpose of this study was to investigate the ability of computed tomography texture analysis (CTTA) to provide additional prognostic information in patients with Hodgkin's lymphoma (HL) and high-grade non-Hodgkin's lymphoma (NHL). This retrospective, pilot-study approved by the IRB comprised 45 lymphoma patients undergoing routine 18F-FDG-PET-CT. Progression-free survival (PFS) was determined from clinical follow-up (mean-duration: 40 months; range: 10-62 months). Non-contrast-enhanced low-dose CT images were submitted to CTTA comprising image filtration to highlight features of different sizes followed by histogram-analysis using kurtosis. Prognostic value of CTTA was compared to PET FDG-uptake value, tumour-stage, tumour-bulk, lymphoma-type, treatment-regime, and interim FDG-PET (iPET) status using Kaplan-Meier analysis. Cox regression analysis determined the independence of significantly prognostic imaging and clinical features. A total of 27 patients had aggressive NHL and 18 had HL. Mean PFS was 48.5 months. There was no significant difference in pre-treatment CTTA between the lymphoma sub-types. Kaplan-Meier analysis found pre-treatment CTTA (medium feature scale, p=0.010) and iPET status (p<0.001) to be significant predictors of PFS. Cox analysis revealed that an interaction between pre-treatment CTTA and iPET status was the only independent predictor of PFS (HR: 25.5, 95% CI: 5.4-120, p<0.001). Specifically, pre-treatment CTTA risk stratified patients with negative iPET. CTTA can potentially provide prognostic information complementary to iPET for patients with HL and aggressive NHL. (orig.)

  8. A fully-automated software pipeline for integrating breast density and parenchymal texture analysis for digital mammograms: parameter optimization in a case-control breast cancer risk assessment study

    Science.gov (United States)

    Zheng, Yuanjie; Wang, Yan; Keller, Brad M.; Conant, Emily; Gee, James C.; Kontos, Despina

    2013-02-01

    Estimating a woman's risk of breast cancer is becoming increasingly important in clinical practice. Mammographic density, estimated as the percent of dense (PD) tissue area within the breast, has been shown to be a strong risk factor. Studies also support a relationship between mammographic texture and breast cancer risk. We have developed a fullyautomated software pipeline for computerized analysis of digital mammography parenchymal patterns by quantitatively measuring both breast density and texture properties. Our pipeline combines advanced computer algorithms of pattern recognition, computer vision, and machine learning and offers a standardized tool for breast cancer risk assessment studies. Different from many existing methods performing parenchymal texture analysis within specific breast subregions, our pipeline extracts texture descriptors for points on a spatial regular lattice and from a surrounding window of each lattice point, to characterize the local mammographic appearance throughout the whole breast. To demonstrate the utility of our pipeline, and optimize its parameters, we perform a case-control study by retrospectively analyzing a total of 472 digital mammography studies. Specifically, we investigate the window size, which is a lattice related parameter, and compare the performance of texture features to that of breast PD in classifying case-control status. Our results suggest that different window sizes may be optimal for raw (12.7mm2) versus vendor post-processed images (6.3mm2). We also show that the combination of PD and texture features outperforms PD alone. The improvement is significant (p=0.03) when raw images and window size of 12.7mm2 are used, having an ROC AUC of 0.66. The combination of PD and our texture features computed from post-processed images with a window size of 6.3 mm2 achieves an ROC AUC of 0.75.

  9. Microstructure and texture evolution in cryorolled Al 7075 alloy

    International Nuclear Information System (INIS)

    Jayaganthan, R.; Brokmeier, H.-G.; Schwebke, Bernd; Panigrahi, S.K.

    2010-01-01

    The present work investigates the microstructure and texture evolution of cryorolled Al 7075 alloy using FE-SEM, TEM, and neutron diffraction, respectively. The solution treated bulk Al 7075 alloy is subjected to rolling at liquid nitrogen temperature to produce sheets with different thickness reductions such as 35%, 50%, 70%, and 90%, respectively. It is evident from the microstructural characterisations of cryorolled samples that with the increasing deformation strain induced in the materials, the grains are fragmented and produce high amount of dislocation density due the suppression of dynamic recovery. The texture analysis of the cryorolled Al 7075 alloy has shown that the ideal fibres observed in the starting solution treated alloy has been destroyed during rolling. The Goss/Brass orientation of the cryorolled Al alloy is shifting towards the Brass components with increasing deformation strain induced in the samples. The orientation distribution functions of the cryorolled Al 7075 alloy clearly indicate the progressive weakening of the texture components, during cryorolling, with increasing strain, therefore, fragmentation and reorientation of micron sized grains occurs easily for the formation of subgrains and ultrafine-grained microstructures as evident from EBSD and TEM micrographs.

  10. Watermarking textures in video games

    Science.gov (United States)

    Liu, Huajian; Berchtold, Waldemar; Schäfer, Marcel; Lieb, Patrick; Steinebach, Martin

    2014-02-01

    Digital watermarking is a promising solution to video game piracy. In this paper, based on the analysis of special challenges and requirements in terms of watermarking textures in video games, a novel watermarking scheme for DDS textures in video games is proposed. To meet the performance requirements in video game applications, the proposed algorithm embeds the watermark message directly in the compressed stream in DDS files and can be straightforwardly applied in watermark container technique for real-time embedding. Furthermore, the embedding approach achieves high watermark payload to handle collusion secure fingerprinting codes with extreme length. Hence, the scheme is resistant to collusion attacks, which is indispensable in video game applications. The proposed scheme is evaluated in aspects of transparency, robustness, security and performance. Especially, in addition to classical objective evaluation, the visual quality and playing experience of watermarked games is assessed subjectively in game playing.

  11. Methods of making textured catalysts

    Science.gov (United States)

    Werpy, Todd [West Richland, WA; Frye, Jr., John G.; Wang, Yong [Richland, WA; Zacher, Alan H [Kennewick, WA

    2010-08-17

    A textured catalyst having a hydrothermally-stable support, a metal oxide and a catalyst component is described. Methods of conducting aqueous phase reactions that are catalyzed by a textured catalyst are also described. The invention also provides methods of making textured catalysts and methods of making chemical products using a textured catalyst.

  12. Total RNA Sequencing Analysis of DCIS Progressing to Invasive Breast Cancer

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-14-1-0080 TITLE: Total RNA Sequencing Analysis of DCIS Progressing to Invasive Breast Cancer . PRINCIPAL INVESTIGATOR...TITLE AND SUBTITLE Total RNA Sequencing Analysis of DCIS Progressing to Invasive Breast Cancer . 5a. CONTRACT NUMBER 5b. GRANT NUMBER GRANT11489...institutional, NIH-funded study of genetic and epigenetic alterations of pre-invasive DCIS that did or did not progress to invasive breast cancer , with an

  13. Automatic classification of cardioembolic and arteriosclerotic ischemic strokes from apparent diffusion coefficient datasets using texture analysis and deep learning

    Science.gov (United States)

    Villafruela, Javier; Crites, Sebastian; Cheng, Bastian; Knaack, Christian; Thomalla, Götz; Menon, Bijoy K.; Forkert, Nils D.

    2017-03-01

    Stroke is a leading cause of death and disability in the western hemisphere. Acute ischemic strokes can be broadly classified based on the underlying cause into atherosclerotic strokes, cardioembolic strokes, small vessels disease, and stroke with other causes. The ability to determine the exact origin of an acute ischemic stroke is highly relevant for optimal treatment decision and preventing recurrent events. However, the differentiation of atherosclerotic and cardioembolic phenotypes can be especially challenging due to similar appearance and symptoms. The aim of this study was to develop and evaluate the feasibility of an image-based machine learning approach for discriminating between arteriosclerotic and cardioembolic acute ischemic strokes using 56 apparent diffusion coefficient (ADC) datasets from acute stroke patients. For this purpose, acute infarct lesions were semi-atomically segmented and 30,981 geometric and texture image features were extracted for each stroke volume. To improve the performance and accuracy, categorical Pearson's χ2 test was used to select the most informative features while removing redundant attributes. As a result, only 289 features were finally included for training of a deep multilayer feed-forward neural network without bootstrapping. The proposed method was evaluated using a leave-one-out cross validation scheme. The proposed classification method achieved an average area under receiver operator characteristic curve value of 0.93 and a classification accuracy of 94.64%. These first results suggest that the proposed image-based classification framework can support neurologists in clinical routine differentiating between atherosclerotic and cardioembolic phenotypes.

  14. On the pleasantness of a haptic stimulation: how different textures can be recognized through heart rate variability nonlinear analysis.

    Science.gov (United States)

    Nardelli, Mimma; Greco, Alberto; Bianchi, Matteo; Scilingo, Enzo Pasquale; Valenza, Gaetano

    2016-08-01

    The hedonic attributes of cutaneous elicitation play a crucial role in everyday life, influencing our behavior and psychophysical state. However, the correlation between such a hedonic aspect of touch and the Autonomic Nervous System (ANS)-related physiological response, which is intimately connected to emotions, still needs to be deeply investigated. This study reports on caress-like stimuli conveyed to the forearm of 32 healthy subjects through different fabrics actuated by a haptic device, which can control both the strength (i.e. the normal force exerted by the fabric) and the velocity of the elicitation. The mimicked caresses were elicited with a fixed force of 6 N, two levels of velocity of 9.4 mm/sec and 65 mm/sec, and four different fabrics with different textures: burlap, hemp, velvet and silk. Participants were asked to score the caress-like stimuli in terms of arousal and valence through a self-assessment questionnaire. Heartbeat data related to the perceived most pleasant (silk) and unpleasant (burlap) fabrics were used as an input to an automatic pattern recognition procedure. Accordingly, considering gender differences, support vector machines using features extracted from linear and nonlinear heartbeat dynamics showed a recognition accuracy of 84.38% (men) and 78.13% (women) while discerning between burlap and silk elicitations at the higher velocity. Results suggest that the fabrics used for the caress-like stimulation significantly affect the nonlinear cardiovascular dynamics, also showing differences according to gender.

  15. Texture analysis of clinical radiographs using radon transform on a local scale for differentiation between post-menopausal women with and without hip fracture

    Science.gov (United States)

    Boehm, Holger F.; Körner, Markus; Baumert, Bernhard; Linsenmaier, Ulrich; Reiser, Maximilian

    2011-03-01

    Osteoporosis is a chronic condition characterized by demineralization and destruction of bone tissue. Fractures associated with the disease are becoming an increasingly relevant issue for public health institutions. Prediction of fracture risk is a major focus research and, over the years, has been approched by various methods. Still, bone mineral density (BMD) obtained by dual-energy X-ray absorptiometry (DXA) remains the clinical gold-standard for diagnosis and follow-up of osteoporosis. However, DXA is restricted to specialized diagnostic centers and there exists considerable overlap in BMD results between populations of individuals with and without fractures. Clinically far more available than DXA is conventional x-ray imaging depicting trabecular bone structure in great detail. In this paper, we demonstrate that bone structure depicted by clinical radiographs can be analysed quantitatively by parameters obtained from the Radon Transform (RT). RT is a global analysis-tool for detection of predefined, parameterized patterns, e.g. straight lines or struts, representing suitable approximations of trabecular bone texture. The proposed algorithm differentiates between patients with and without fractures of the hip by application of various texture-metrics based on the Radon-Transform to standard x-ray images of the proximal femur. We consider three different regions-of-interest in the proximal femur (femoral head, neck, and inter-trochanteric area), and conduct an analysis with respect to correct classification of the fracture status. Performance of the novel approach is compared to DXA. We draw the conclusion that performance of RT is comparable to DXA and may become a useful supplement to densitometry for the prediction of fracture risk.

  16. TU-D-207B-03: Early Assessment of Response to Chemoradiotherapy Based On Textural Analysis of Pre and Mid-Treatment FDG-PET Image in Locally Advanced Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Y; Pollom, E; Loo, B; Le, Q; Hara, W; Li, R [Stanford University, Palo Alto, CA (United States)

    2016-06-15

    Purpose: To evaluate whether tumor textural features extracted from both pre- and mid-treatment FDG-PET images predict early response to chemoradiotherapy in locally advanced head and neck cancer, and investigate whether they provide complementary value to conventional volume-based measurements. Methods: Ninety-four patients with locally advanced head and neck cancers were retrospectively studied. All patients received definitive chemoradiotherapy and underwent FDG-PET planning scans both before and during treatment. Within the primary tumor we extracted 6 textural features based on gray-level co-occurrence matrices (GLCM): entropy, dissimilarity, contrast, correlation, energy, and homogeneity. These image features were evaluated for their predictive power of treatment response to chemoradiotherapy in terms of local recurrence free survival (LRFS) and progression free survival (PFS). Logrank test were used to assess the statistical significance of the stratification between low- and high-risk groups. P-values were adjusted for multiple comparisons by the false discovery rate (FDR) method. Results: All six textural features extracted from pre-treatment PET images significantly differentiated low- and high-risk patient groups for LRFS (P=0.011–0.038) and PFS (P=0.029–0.034). On the other hand, none of the textural features on mid-treatment PET images was statistically significant in stratifying LRFS (P=0.212–0.445) or PFS (P=0.168–0.299). An imaging signature that combines textural feature (GLCM homogeneity) and metabolic tumor volume showed an improved performance for predicting LRFS (hazard ratio: 22.8, P<0.0001) and PFS (hazard ratio: 13.9, P=0.0005) in leave-one-out cross validation. Intra-tumor heterogeneity measured by textural features was significantly lower in mid-treatment PET images than in pre-treatment PET images (T-test: P<1.4e-6). Conclusion: Tumor textural features on pretreatment FDG-PET images are predictive for response to chemoradiotherapy

  17. Computer Texture Mapping for Laser Texturing of Injection Mold

    Directory of Open Access Journals (Sweden)

    Yongquan Zhou

    2014-04-01

    Full Text Available Laser texturing is a relatively new multiprocess technique that has been used for machining 3D curved surfaces; it is more flexible and efficient to create decorative texture on 3D curved surfaces of injection molds so as to improve the surface quality and achieve cosmetic surface of molded plastic parts. In this paper, a novel method of laser texturing 3D curved surface based on 3-axis galvanometer scanning unit has been presented to prevent the texturing of injection mold surface from much distortion which is often caused by traditional texturing processes. The novel method has been based on the computer texture mapping technology which has been developed and presented. The developed texture mapping algorithm includes surface triangulation, notations, distortion measurement, control, and numerical method. An interface of computer texture mapping has been built to implement the algorithm of texture mapping approach to controlled distortion rate of 3D texture math model from 2D original texture applied to curvature surface. Through a case study of laser texturing of a high curvature surface of injection mold of a mice top case, it shows that the novel method of laser texturing meets the quality standard of laser texturing of injection mold.

  18. Texture analysis of high-resolution dedicated breast {sup 18}F-FDG PET images correlates with immunohistochemical factors and subtype of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Moscoso, Alexis; Dominguez-Prado, Ines; Herranz, Michel; Argibay, Sonia; Silva-Rodriguez, Jesus [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); Ruibal, Alvaro [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); University of Santiago de Compostela (USC), Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Santiago de Compostela (Spain); Fundacion Tejerina, Madrid (Spain); Fernandez-Ferreiro, Anxo [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Pharmacy Department and Pharmacology Group, Santiago de Compostela (Spain); Albaina, Luis [University Hospital A Coruna (SERGAS), Department of General Surgery, A Coruna (Spain); Pardo-Montero, Juan [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); Complexo Hospitalario Universitario de Santiago de Compostela (CHUS), Medical Physics Department, Santiago de Compostela (Spain); Aguiar, Pablo [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); University of Santiago de Compostela (USC), Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Santiago de Compostela (Spain)

    2018-02-15

    This study aims to determine whether PET textural features measured with a new dedicated breast PET scanner reflect biological characteristics of breast tumors. One hundred and thirty-nine breast tumors from 127 consecutive patients were included in this analysis. All of them underwent a {sup 18}F-FDG PET scan before treatment. Well-known PET quantitative parameters such as SUV{sub m} {sub a} {sub x}, SUV{sub m} {sub e} {sub a} {sub n}, metabolically active tumor volume (MATV) and total lesion glycolysis (TLG) were extracted. Together with these parameters, local, regional, and global heterogeneity descriptors, which included five textural features (TF), were computed. Immunohistochemical classification of breast cancer considered five subtypes: luminal A like (LA), luminal B like/HER2 - (LB -), luminal B like/HER2+ (LB+), HER2-positive-non-luminal (HER2pnl), and triple negative (TN). Associations between PET features and tumor characteristics were assessed using non-parametric hypothesis tests. Along with well-established associations, new correlations were found. HER2-positive tumors had significantly higher uptake (p < 0.001, AUCs > 0.70) and presented different global and regional heterogeneity (p = 0.002, p = 0.016, respectively, AUCs < 0.70). Nine out of ten analyzed features were significantly associated with immunohistochemical subtype. Uptake was lower for LA tumors (p < 0.001) with AUCs ranging from 0.71 to 0.88 for each subgroup comparison. Heterogeneity metrics were significantly associated when comparing LA and LB - (p < 0.01), being regional heterogeneity metrics more discriminative than any other parameter (AUC = 0.80 compared to AUC = 0.71 for SUV). LB+ and HER2pnl tumors also showed more regional heterogeneity than LA tumors (AUCs = 0.79 and 0.84, respectively). After comparison with whole-body PET studies, we observed an overall improvement in the classification ability of both non-heterogeneity metrics and textural features. PET parameters

  19. An introductory analysis of digital infrared thermal imaging guided oral cancer detection using multiresolution rotation invariant texture features

    Science.gov (United States)

    Chakraborty, M.; Das Gupta, R.; Mukhopadhyay, S.; Anjum, N.; Patsa, S.; Ray, J. G.

    2017-03-01

    This manuscript presents an analytical treatment on the feasibility of multi-scale Gabor filter bank response for non-invasive oral cancer pre-screening and detection in the long infrared spectrum. Incapability of present healthcare technology to detect oral cancer in budding stage manifests in high mortality rate. The paper contributes a step towards automation in non-invasive computer-aided oral cancer detection using an amalgamation of image processing and machine intelligence paradigms. Previous works have shown the discriminative difference of facial temperature distribution between a normal subject and a patient. The proposed work, for the first time, exploits this difference further by representing the facial Region of Interest(ROI) using multiscale rotation invariant Gabor filter bank responses followed by classification using Radial Basis Function(RBF) kernelized Support Vector Machine(SVM). The proposed study reveals an initial increase in classification accuracy with incrementing image scales followed by degradation of performance; an indication that addition of more and more finer scales tend to embed noisy information instead of discriminative texture patterns. Moreover, the performance is consistently better for filter responses from profile faces compared to frontal faces.This is primarily attributed to the ineptness of Gabor kernels to analyze low spatial frequency components over a small facial surface area. On our dataset comprising of 81 malignant, 59 pre-cancerous, and 63 normal subjects, we achieve state-of-the-art accuracy of 85.16% for normal v/s precancerous and 84.72% for normal v/s malignant classification. This sets a benchmark for further investigation of multiscale feature extraction paradigms in IR spectrum for oral cancer detection.

  20. WE-E-17A-05: Complementary Prognostic Value of CT and 18F-FDG PET Non-Small Cell Lung Cancer Tumor Heterogeneity Features Quantified Through Texture Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Desseroit, M; Cheze Le Rest, C; Tixier, F [CHU Poitiers Poitiers (France); INSERM LaTIM UMR 1101, Brest (France); Majdoub, M; Visvikis, D; Hatt, M [INSERM LaTIM UMR 1101, Brest (France); Guillevin, R; Perdrisot, R [CHU Poitiers Poitiers (France)

    2014-06-15

    Purpose: Previous studies have shown that CT or 18F-FDG PET intratumor heterogeneity features computed using texture analysis may have prognostic value in Non-Small Cell Lung Cancer (NSCLC), but have been mostly investigated separately. The purpose of this study was to evaluate the potential added value with respect to prognosis regarding the combination of non-enhanced CT and 18F-FDG PET heterogeneity textural features on primary NSCLC tumors. Methods: One hundred patients with non-metastatic NSCLC (stage I–III), treated with surgery and/or (chemo)radiotherapy, that underwent staging 18F-FDG PET/CT images, were retrospectively included. Morphological tumor volumes were semi-automatically delineated on non-enhanced CT using 3D SlicerTM. Metabolically active tumor volumes (MATV) were automatically delineated on PET using the Fuzzy Locally Adaptive Bayesian (FLAB) method. Intratumoral tissue density and FDG uptake heterogeneities were quantified using texture parameters calculated from co-occurrence, difference, and run-length matrices. In addition to these textural features, first order histogram-derived metrics were computed on the whole morphological CT tumor volume, as well as on sub-volumes corresponding to fine, medium or coarse textures determined through various levels of LoG-filtering. Association with survival regarding all extracted features was assessed using Cox regression for both univariate and multivariate analysis. Results: Several PET and CT heterogeneity features were prognostic factors of overall survival in the univariate analysis. CT histogram-derived kurtosis and uniformity, as well as Low Grey-level High Run Emphasis (LGHRE), and PET local entropy were independent prognostic factors. Combined with stage and MATV, they led to a powerful prognostic model (p<0.0001), with median survival of 49 vs. 12.6 months and a hazard ratio of 3.5. Conclusion: Intratumoral heterogeneity quantified through textural features extracted from both CT and FDG PET

  1. PREFACE: 17th International Conference on Textures of Materials (ICOTOM 17)

    Science.gov (United States)

    Skrotzki, Werner; Oertel, Carl-Georg

    2015-04-01

    The 17th International Conference on Textures of Materials (ICOTOM 17) took place in Dresden, Germany, August 24-29, 2014. It belongs to the "triennial" series of ICOTOM meetings with a long tradition, starting in 1969 - Clausthal, 1971 - Cracow, 1973 - Pont-à-Mousson, 1975 - Cambridge, 1978 - Aachen, 1981 - Tokyo, 1984 - Noordwijkerhout, 1987 - Santa Fe, 1990 - Avignon, 1993 - Clausthal, 1996 - Xian, 1999 - Montreal, 2002 - Seoul, 2005 - Leuven, 2008 - Pittsburgh, 2011 - Mumbai, 2014 - Dresden. ICOTOM 17 was hosted by the Dresden University of Technology, Institute of Structural Physics. Following the tradition of the ICOTOM conferences, the main focus of ICOTOM-17 was to promote and strengthen the fundamental understanding of the basic processes that govern the formation of texture and its relation to the properties of polycrystalline materials. Nonetheless, it was the aim to forge links between basic research on model materials and applied research on engineering materials of technical importance. Thus, ICOTOM 17 provided a forum for the presentation and discussion of recent progress in research of texture and related anisotropy of mechanical and functional properties of all kinds of polycrystalline materials including natural materials like rocks. Particular attention was paid to recent advances in texture measurement and analysis as well as modeling of texture development for all kinds of processes like solidification, plastic deformation, recrystallization and grain growth, phase transformations, thin film deposition, etc. Hence, ICOTOM 17 was of great interest to materials scientists, engineers from many different areas and geoscientists. The topics covered by ICOTOM 17 were: 1. Mathematical, numerical and statistical methods of texture analysis 2. Deformation textures 3. Crystallization, recrystallization and growth textures 4. Transformation textures 5. Textures in functional materials 6. Textures in advanced materials 7. Textures in rocks 8. Texture

  2. Ion-beam texturing of uniaxially textured Ni films

    International Nuclear Information System (INIS)

    Park, S.J.; Norton, D.P.; Selvamanickam, Venkat

    2005-01-01

    The formation of biaxial texture in uniaxially textured Ni thin films via Ar-ion irradiation is reported. The ion-beam irradiation was not simultaneous with deposition. Instead, the ion beam irradiates the uniaxially textured film surface with no impinging deposition flux, which differs from conventional ion-beam-assisted deposition. The uniaxial texture is established via a nonion beam process, with the in-plane texture imposed on the uniaxial film via ion beam bombardment. Within this sequential ion beam texturing method, grain alignment is driven by selective etching and grain overgrowth

  3. Non-Hodgkin lymphoma response evaluation with MRI texture classification

    Directory of Open Access Journals (Sweden)

    Heinonen Tomi T

    2009-06-01

    Full Text Available Abstract Background To show magnetic resonance imaging (MRI texture appearance change in non-Hodgkin lymphoma (NHL during treatment with response controlled by quantitative volume analysis. Methods A total of 19 patients having NHL with an evaluable lymphoma lesion were scanned at three imaging timepoints with 1.5T device during clinical treatment evaluation. Texture characteristics of images were analyzed and classified with MaZda application and statistical tests. Results NHL tissue MRI texture imaged before treatment and under chemotherapy was classified within several subgroups, showing best discrimination with 96% correct classification in non-linear discriminant analysis of T2-weighted images. Texture parameters of MRI data were successfully tested with statistical tests to assess the impact of the separability of the parameters in evaluating chemotherapy response in lymphoma tissue. Conclusion Texture characteristics of MRI data were classified successfully; this proved texture analysis to be potential quantitative means of representing lymphoma tissue changes during chemotherapy response monitoring.

  4. Thermodynamic Activity-Based Progress Curve Analysis in Enzyme Kinetics.

    Science.gov (United States)

    Pleiss, Jürgen

    2018-03-01

    Macrokinetic Michaelis-Menten models based on thermodynamic activity provide insights into enzyme kinetics because they separate substrate-enzyme from substrate-solvent interactions. Kinetic parameters are estimated from experimental progress curves of enzyme-catalyzed reactions. Three pitfalls are discussed: deviations between thermodynamic and concentration-based models, product effects on the substrate activity coefficient, and product inhibition. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Analysis of interventional therapy for progressing stage gastric cancer

    International Nuclear Information System (INIS)

    Zhu Mingde; Zhang Zijing; Ji Hongsheng; Ge Chenlin; Hao Gang; Wei Kongming; Yuan Yuhou; Zhao Xiuping

    2008-01-01

    Objective: To investigate the interventional therapy and its curative effect for progressing stage gastric cancer. Methods: two hundred and twelve patients with progressing stage gastric cancer were treated with arterial perfusion and arterial embolization. Gastric cardia cancer was treated through the left gastric artery and the left inferior phrenic artery or splenic artery. Cancers of lesser and greater gastric curvature was treated either through the left and right gastric arteries or common hepatic artery or through gastroduodenal artery, right gastroomental artery or splenic artery. Gastric antrum cancers were perfused through gastroduodenal artery or after the middle segmental embolization of right gastroomental artery. Results: One hundred and ninety three cases undergone interventional management were followed up. The CR + PR of gastric cardia cancer was 53.13%; gastric body cancer 44.44%; gastric antrum cancer 10%; recurrent cancer and remnant gastric cancer 0. There was no significant difference in outcome between gastric cardia cancer and gastric body cancer (P>0.05) but significant differences were shown both between gastric cardia cancer and gastric antrum cancer, and between gastric body cancer and gastric antrum cancer (P<0.05), with 1 year and 2 years survival rates of 81% and 56% respectively. Conclusion: The interventional therapeutic effect of progressing stage gastric cancers is different due to the different sites of the lesions in the gastric tissue. The curative effect of gastric cardia cancer and gastric body cancer is better than that of gastric antrum cancer, recurrent cancer and remnant gastric cancer. (authors)

  6. A pilot study for texture analysis of {sup 18}F-FDG and {sup 18}F-FLT-PET/CT to predict tumor recurrence of patients with colorectal cancer who received surgery

    Energy Technology Data Exchange (ETDEWEB)

    Nakajo, Masatoyo; Tani, Atsushi; Jinguji, Megumi; Yoshiura, Takashi [Kagoshima University, Department of Radiology, Graduate School of Medical and Dental Sciences, Kagoshima (Japan); Kajiya, Yoriko; Nakajo, Masayuki [Nanpuh Hospital, Department of Radiology, Kagoshima (Japan); Kitazono, Masaki [Nanpuh Hospital, Department of Surgery, Kagoshima (Japan)

    2017-12-15

    This retrospective study was done to examine whether the heterogeneity in primary tumor F-18-fluorodeoxyglucose ({sup 18}F-FDG) and {sup 18}F-3'-fluoro-3'-deoxythymidine ({sup 18}F-FLT) distribution can predict prognosis of patients with colorectal cancer who received surgery. The enrolled 32 patients with colorectal cancer underwent both {sup 18}F-FDG- and {sup 18}F-FLT-PET/CT studies before surgery. Clinicopathological factors, stage, SUVmax, SUVmean, metabolic tumor volume (SUV ≥ 2.5), total lesion glycolysis, total lesion proliferation and seven texture heterogeneity parameters (coefficient of variation, local parameters: entropy, homogeneity, and dissimilarity; and regional parameters: intensity variability [IV], size-zone variability [SZV], and zone percentage [ZP]) were obtained. Progression free survival (PFS) was calculated by the Kaplan-Meier method. Prognostic significance was assessed by Cox proportional hazards analysis. Eight patients had eventually come to progression, and 24 patients were alive without progression during clinical follow-up [mean follow-up PFS; 55.9 months (range, 1-72)]. High stage (p = 0.004), high {sup 18}F-FDG-IV (p = 0.015), high {sup 18}F-FDG-SZV (p = 0.013) and high {sup 18}F-FLT-entropy (p = 0.015) were significant in predicting poor 5-year PFS. Other parameters did not predict the disease outcome. At bivariate analysis, disease event hazards ratios for {sup 18}F-FDG-IV and {sup 18}F-FDG-SZV remained significant when adjusted for stage and {sup 18}F-FLT-entropy ({sup 18}F-FDG-IV; p = 0.004 [adjusted for stage], 0.007 [adjusted for {sup 18}F-FLT-entropy]; {sup 18}F-FDG-SZV; p = 0.028 [adjusted for stage], 0.040 [adjusted for {sup 18}F-FLT-entropy]). {sup 18}F-FDG PET heterogeneity parameters, IV and SZV, have a potential to be strong prognostic factors to predict PFS of patients with surgically resected colorectal cancer and are more useful than {sup 18}F-FLT-PET/CT heterogeneity parameters. (orig.)

  7. Progress on radiochemical analysis for nuclear waste management in decommissioning

    Energy Technology Data Exchange (ETDEWEB)

    Hou, X. (Technical Univ. of Denmark. Center for Nuclear Technologies (NuTech), Roskilde (Denmark))

    2012-01-15

    This report summarized the progress in the development and improvement of radioanalytical methods for decommissioning and waste management completed in the NKS-B RadWaste 2011 project. Based on the overview information of the analytical methods in Nordic laboratories and requirement from the nuclear industry provided in the first phase of the RadWaste project (2010), some methods were improved and developed. A method for efficiently separation of Nb from nuclear waste especially metals for measurement of long-lived 94Nb by gamma spectrometry was developed. By systematic investigation of behaviours of technetium in sample treatment and chromatographic separation process, an effective method was developed for the determination of low level 99Tc in waste samples. An AMS approachment was investigated to measure ultra low level 237Np using 242Pu for AMS normalization, the preliminary results show a high potential of this method. Some progress on characterization of waste for decommissioning of Danish DR3 is also presented. (Author)

  8. Progress on radiochemical analysis for nuclear waste management in decommissioning

    International Nuclear Information System (INIS)

    Hou, X.

    2012-01-01

    This report summarized the progress in the development and improvement of radioanalytical methods for decommissioning and waste management completed in the NKS-B RadWaste 2011 project. Based on the overview information of the analytical methods in Nordic laboratories and requirement from the nuclear industry provided in the first phase of the RadWaste project (2010), some methods were improved and developed. A method for efficiently separation of Nb from nuclear waste especially metals for measurement of long-lived 94Nb by gamma spectrometry was developed. By systematic investigation of behaviours of technetium in sample treatment and chromatographic separation process, an effective method was developed for the determination of low level 99Tc in waste samples. An AMS approachment was investigated to measure ultra low level 237Np using 242Pu for AMS normalization, the preliminary results show a high potential of this method. Some progress on characterization of waste for decommissioning of Danish DR3 is also presented. (Author)

  9. Semantic attributes based texture generation

    Science.gov (United States)

    Chi, Huifang; Gan, Yanhai; Qi, Lin; Dong, Junyu; Madessa, Amanuel Hirpa

    2018-04-01

    Semantic attributes are commonly used for texture description. They can be used to describe the information of a texture, such as patterns, textons, distributions, brightness, and so on. Generally speaking, semantic attributes are more concrete descriptors than perceptual features. Therefore, it is practical to generate texture images from semantic attributes. In this paper, we propose to generate high-quality texture images from semantic attributes. Over the last two decades, several works have been done on texture synthesis and generation. Most of them focusing on example-based texture synthesis and procedural texture generation. Semantic attributes based texture generation still deserves more devotion. Gan et al. proposed a useful joint model for perception driven texture generation. However, perceptual features are nonobjective spatial statistics used by humans to distinguish different textures in pre-attentive situations. To give more describing information about texture appearance, semantic attributes which are more in line with human description habits are desired. In this paper, we use sigmoid cross entropy loss in an auxiliary model to provide enough information for a generator. Consequently, the discriminator is released from the relatively intractable mission of figuring out the joint distribution of condition vectors and samples. To demonstrate the validity of our method, we compare our method to Gan et al.'s method on generating textures by designing experiments on PTD and DTD. All experimental results show that our model can generate textures from semantic attributes.

  10. Heterogeneous patterns enhancing static and dynamic texture classification

    International Nuclear Information System (INIS)

    Silva, Núbia Rosa da; Martinez Bruno, Odemir

    2013-01-01

    Some mixtures, such as colloids like milk, blood, and gelatin, have homogeneous appearance when viewed with the naked eye, however, to observe them at the nanoscale is possible to understand the heterogeneity of its components. The same phenomenon can occur in pattern recognition in which it is possible to see heterogeneous patterns in texture images. However, current methods of texture analysis can not adequately describe such heterogeneous patterns. Common methods used by researchers analyse the image information in a global way, taking all its features in an integrated manner. Furthermore, multi-scale analysis verifies the patterns at different scales, but still preserving the homogeneous analysis. On the other hand various methods use textons to represent the texture, breaking texture down into its smallest unit. To tackle this problem, we propose a method to identify texture patterns not small as textons at distinct scales enhancing the separability among different types of texture. We find sub patterns of texture according to the scale and then group similar patterns for a more refined analysis. Tests were performed in four static texture databases and one dynamical one. Results show that our method provide better classification rate compared with conventional approaches both in static and in dynamic texture.

  11. Chameleons: Reptilian Texture

    Science.gov (United States)

    Petersen, Hugh

    2009-01-01

    This article presents an art project inspired by a drawing of a chameleon the author saw in an art-supply catalog. Chameleons prove to be a good subject to highlight shape, color and texture with eigth-graders. In this project, middle- and high-school students draw a chameleon, learn how to use shapes to add to their chameleon drawing, learn how…

  12. Strings, texture, and inflation

    International Nuclear Information System (INIS)

    Hodges, H.M.; Primack, J.R.

    1991-01-01

    We examine mechanisms, several of which are proposed here, to generate structure formation, or to just add large-scale features, through either gauged or global cosmic strings or global texture, within the framework of inflation. We first explore the possibility that strings or texture form if there is no coupling between the topological theory and the inflaton or spacetime curvature, via (1) quantum creation, and (2) a sufficiently high reheat temperature. In addition, we examine the prospects for the inflaton field itself to generate strings or texture. Then, models with the string/texture field coupled to the curvature, and an equivalent model with coupling to the inflaton field, are considered in detail. The requirement that inflationary density fluctuations are not so large as to conflict with observations leads to a number of constraints on model parameters. We find that strings of relevance for structure formation can form in the absence of coupling to the inflaton or curvature through the process of quantum creation, but only if the strings are strongly type I, or if they are global strings. If formed after reheating, naturalness suggests that gauged cosmic strings correspond to a type-I superconductor. Similarly, gauged strings formed during inflation via conformal coupling ξ=1/6 to the spacetime curvature (in a model suggested by Yokoyama in order to evade the millisecond pulsar constraint on cosmic strings) are expected to be strongly type I

  13. Hierarchical cluster analysis of progression patterns in open-angle glaucoma patients with medical treatment.

    Science.gov (United States)

    Bae, Hyoung Won; Rho, Seungsoo; Lee, Hye Sun; Lee, Naeun; Hong, Samin; Seong, Gong Je; Sung, Kyung Rim; Kim, Chan Yun

    2014-04-29

    To classify medically treated open-angle glaucoma (OAG) by the pattern of progression using hierarchical cluster analysis, and to determine OAG progression characteristics by comparing clusters. Ninety-five eyes of 95 OAG patients who received medical treatment, and who had undergone visual field (VF) testing at least once per year for 5 or more years. OAG was classified into subgroups using hierarchical cluster analysis based on the following five variables: baseline mean deviation (MD), baseline visual field index (VFI), MD slope, VFI slope, and Glaucoma Progression Analysis (GPA) printout. After that, other parameters were compared between clusters. Two clusters were made after a hierarchical cluster analysis. Cluster 1 showed -4.06 ± 2.43 dB baseline MD, 92.58% ± 6.27% baseline VFI, -0.28 ± 0.38 dB per year MD slope, -0.52% ± 0.81% per year VFI slope, and all "no progression" cases in GPA printout, whereas cluster 2 showed -8.68 ± 3.81 baseline MD, 77.54 ± 12.98 baseline VFI, -0.72 ± 0.55 MD slope, -2.22 ± 1.89 VFI slope, and seven "possible" and four "likely" progression cases in GPA printout. There were no significant differences in age, sex, mean IOP, central corneal thickness, and axial length between clusters. However, cluster 2 included more high-tension glaucoma patients and used a greater number of antiglaucoma eye drops significantly compared with cluster 1. Hierarchical cluster analysis of progression patterns divided OAG into slow and fast progression groups, evidenced by assessing the parameters of glaucomatous progression in VF testing. In the fast progression group, the prevalence of high-tension glaucoma was greater and the number of antiglaucoma medications administered was increased versus the slow progression group. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  14. Some Numerical Characteristics of Image Texture

    Directory of Open Access Journals (Sweden)

    O. Samarina

    2012-05-01

    Full Text Available Texture classification is one of the basic images processing tasks. In this paper we present some numerical characteristics to the images analysis and processing. It can be used at the solving of images classification problems, their recognition, problems of remote sounding, biomedical images analysis, geological researches.

  15. Perceptual asymmetry in texture perception.

    OpenAIRE

    Williams, D; Julesz, B

    1992-01-01

    A fundamental property of human visual perception is our ability to distinguish between textures. A concerted effort has been made to account for texture segregation in terms of linear spatial filter models and their nonlinear extensions. However, for certain texture pairs the ease of discrimination changes when the role of figure and ground are reversed. This asymmetry poses a problem for both linear and nonlinear models. We have isolated a property of texture perception that can account for...

  16. A Noise Robust Statistical Texture Model

    DEFF Research Database (Denmark)

    Hilger, Klaus Baggesen; Stegmann, Mikkel Bille; Larsen, Rasmus

    2002-01-01

    Appearance Models segmentation framework. This is accomplished by augmenting the model with an estimate of the covariance of the noise present in the training data. This results in a more compact model maximising the signal-to-noise ratio, thus favouring subspaces rich on signal, but low on noise......This paper presents a novel approach to the problem of obtaining a low dimensional representation of texture (pixel intensity) variation present in a training set after alignment using a Generalised Procrustes analysis.We extend the conventional analysis of training textures in the Active...

  17. TU-F-12A-09: GLCM Texture Analysis for Normal-Tissue Toxicity: A Prospective Ultrasound Study of Acute Toxicity in Breast-Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, T; Yang, X; Curran, W; Torres, M [Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA (United States)

    2014-06-15

    Purpose: To evaluate the morphologic and structural integrity of the breast glands using sonographic textural analysis, and identify potential early imaging signatures for radiation toxicity following breast-cancer radiotherapy (RT). Methods: Thirty-eight patients receiving breast RT participated in a prospective ultrasound imaging study. Each participant received 3 ultrasound scans: 1 week before RT (baseline), and at 6-week and 3-month follow-ups. Patients were imaged with a 10-MHz ultrasound on the four quadrant of the breast. A second order statistical method of texture analysis, called gray level co-occurrence matrix (GLCM), was employed to assess RT-induced breast-tissue toxicity. The region of interest (ROI) was 28 mm × 10 mm in size at a 10 mm depth under the skin. Twenty GLCM sonographic features, ratios of the irradiated breast and the contralateral breast, were used to quantify breast-tissue toxicity. Clinical assessment of acute toxicity was conducted using the RTOG toxicity scheme. Results: Ninety-seven ultrasound studies (776 images) were analyzed; and 5 out of 20 sonographic features showed significant differences (p < 0.05) among the baseline scans, the acute toxicity grade 1 and 2 groups. These sonographic features quantified the degree of tissue damage through homogeneity, heterogeneity, randomness, and symmetry. Energy ratio value decreased from 108±0.05 (normal) to 0.99±0.05 (Grade 1) and 0.84±0.04 (Grade 2); Entropy ratio value increased from 1.01±0.01 to 1.02±0.01 and 1.04±0.01; Contrast ratio value increased from 1.03±0.03 to 1.07±0.06 and 1.21±0.09; Variance ratio value increased from 1.06±0.03 to 1.20±0.04 and 1.42±0.10; Cluster Prominence ratio value increased from 0.98±0.02 to 1.01±0.04 and 1.25±0.07. Conclusion: This work has demonstrated that the sonographic features may serve as imaging signatures to assess radiation-induced normal tissue damage. While these findings need to be validated in a larger cohort, they suggest

  18. Multi-scale analysis by SEM, EBSD and X-ray diffraction of deformation textures of a copper wire drawn industrially

    Directory of Open Access Journals (Sweden)

    Zidani M.

    2013-09-01

    Full Text Available In this study, we tried to understand the texture evolution of deformation during the cold drawing of copper wire (99.26% Drawn by the company ENICAB destined for electrical cabling and understand its link with the electrical conductivity. Characterisations performed show the appearance and texture development during the reduction of section of the wire. The texture is mainly composed of the fiber // DN (DN // drawing axis (majority and the fiber // ND (minority whose acuity increases with deformation level. The wire was performed for the main components of the texture, ie the fiber and conventionally present in these materials. We will pay particular attention on the energy of the cube component {100} recrystallization that develops when the level of reduction is sufficient. There was also an increase in hardness and electrical resistivity along the applied deformation.

  19. X-ray diffraction stress analysis of ferroelectric thin films with ideal (h k l) textures considering the piezoelectric coupling effect

    International Nuclear Information System (INIS)

    Wu Huaping; Wu Linzhi; Li Jiquan; Chai Guozhong; Du Shanyi

    2010-01-01

    Ferroelectric thin films present large residual stress and strong texture during preparation, which affect the mechanical, dielectric and piezoelectric properties of the thin films. The determination of residual stresses in ferroelectric thin films with different textures is therefore very important. In this paper, an extended crystallite group model to evaluate the residual stresses of ferroelectric thin films using X-ray diffraction is proposed by considering the constitutive equation of orthogonally anisotropic ferroelectric medium. The effects of anisotropy and piezoelectric coupling on residual stresses of ferroelectric thin films are analyzed. X-ray stress factors for ideal (h k l)-textured ferroelectric thin films are obtained. An example of calculating the residual stresses of tetragonal perovskite ferroelectric thin films with (1 1 1) and (1 0 0) textures using the extended model is provided to validate the model.

  20. Texture and deformation mechanism of yttrium

    International Nuclear Information System (INIS)

    Adamesku, R.A.; Grebenkin, S.V.; Stepanenko, A.V.

    1992-01-01

    X-ray pole figure analysis was applied to study texture and deformation mechanism in pure and commercial polycrystalline yttrium on cold working. It was found that in cast yttrium the texture manifected itself weakly enough both for pure and commercial metal. Analysis of the data obtained made it possible to assert that cold deformation of pure yttrium in the initial stage occurred mainly by slip the role of which decreased at strains higher than 36%. The texture of heavily deformed commercial yttrium contained two components, these were an 'ideal' basic orientation and an axial one with the angle of inclination about 20 deg. Twinning mechanism was revealed to be also possible in commercial yttrium

  1. Textural analysis of particles from El Zaguán debris avalanche deposit, Nevado de Toluca volcano, Mexico: Evidence of flow behavior during emplacement

    Science.gov (United States)

    Caballero, Lizeth; Capra, Lucia

    2011-02-01

    El Zaguán deposit originated at 28,000 yrs. B.P. from the flank collapse of Nevado de Toluca, a dacitic stratovolcano of the Transmexican Volcanic Belt. Scanning Electron Microprobe analyses (SEM) were performed on some particles from this deposit to observe microtextures produced during transport and emplacement of the debris avalanche flow. Particles from 2ϕ (250 μm), 0ϕ (1 mm) and - 2ϕ (4 mm) granulometric classes were randomly selected at different outcrops, and their surface textures were described. The observed textures are divided in two groups, Basal and Upper textures, each one indicating different clast interactions. Basal textures are observed predominantly in the lower part of the deposit and consist of parallel ridges, parallel grooves, scratches and lips. Upper textures are mainly present in the upper part of the deposit and consisted of fractures, percussion marks, and broken or grinded crystals. These characteristics, coupled with field observations such as the presence of clastic dikes and deformed lacustrine mega-blocks, indicate that the basal part of the debris avalanche was moving in a partially liquefied state. By contrast, the particles in the upper part were able to move freely, interacting by collision. These microscopic textures are in agreement with previously described emplacement behaviors in debris avalanches of volcanic origin, suggesting a stratified flow dominated by different transport and depositional mechanisms depending upon flow depth and possible fluid content at their base.

  2. Cloud field classification based on textural features

    Science.gov (United States)

    Sengupta, Sailes Kumar

    1989-01-01

    An essential component in global climate research is accurate cloud cover and type determination. Of the two approaches to texture-based classification (statistical and textural), only the former is effective in the classification of natural scenes such as land, ocean, and atmosphere. In the statistical approach that was adopted, parameters characterizing the stochastic properties of the spatial distribution of grey levels in an image are estimated and then used as features for cloud classification. Two types of textural measures were used. One is based on the distribution of the grey level difference vector (GLDV), and the other on a set of textural features derived from the MaxMin cooccurrence matrix (MMCM). The GLDV method looks at the difference D of grey levels at pixels separated by a horizontal distance d and computes several statistics based on this distribution. These are then used as features in subsequent classification. The MaxMin tectural features on the other hand are based on the MMCM, a matrix whose (I,J)th entry give the relative frequency of occurrences of the grey level pair (I,J) that are consecutive and thresholded local extremes separated by a given pixel distance d. Textural measures are then computed based on this matrix in much the same manner as is done in texture computation using the grey level cooccurrence matrix. The database consists of 37 cloud field scenes from LANDSAT imagery using a near IR visible channel. The classification algorithm used is the well known Stepwise Discriminant Analysis. The overall accuracy was estimated by the percentage or correct classifications in each case. It turns out that both types of classifiers, at their best combination of features, and at any given spatial resolution give approximately the same classification accuracy. A neural network based classifier with a feed forward architecture and a back propagation training algorithm is used to increase the classification accuracy, using these two classes

  3. Novel Texture-based Probabilistic Object Recognition and Tracking Techniques for Food Intake Analysis and Traffic Monitoring

    Science.gov (United States)

    2015-10-02

    International Conference on, pages 25–30, July 2012. [126] I. Matthews, T. Ishikawa , and S. Baker. The template update problem. Pattern Analysis and Machine...and Kaoru Ko- hyama. Visual illusion in mass estimation of cut food. APPETITE, 49(1):183–190, JUL 2007. [181] E.A. Wan and R. Van Der Merwe. The

  4. Defect analysis program for LOFT. Progress report, 1977

    International Nuclear Information System (INIS)

    Doyle, R.E.; Scoonover, T.M.

    1978-03-01

    In order to alleviate problems encountered while performing previous defect analyses on components of the LOFT system, regions of LOFT most likely to require defect analysis have been identified. A review of available documentation has been conducted to identify shapes, sizes, materials, and welding procedures and to compile mechanical property data. The LOFT Reactor Vessel Material Surveillance Program has also been reviewed, and a survey of available literature describing existing techniques for conducting elastic-plastic defect analysis was initiated. While large amounts of mechanical property data were obtained from the available documentation and the literature, much information was not available, especially for weld heat-affected zones. Therefore, a program of mechanical property testing is recommended for FY-78 as well as continued literature search. It is also recommended that fatigue-crack growth-rate data be sought from the literature and that evaluation of the various techniques of elastic-plastic defect analysis be continued. Review of additional regions of the LOFT system in the context of potential defect analysis will be conducted as time permits

  5. Progress in structural analysis of glycosaminoglycans and their ...

    African Journals Online (AJOL)

    Yomi

    2012-03-06

    Mar 6, 2012 ... The rising interest in the application of glycosaminoglycans (GAGs) is ... in functional food, clinical medicine, cosmetics and biomaterial. .... labor leads to incomplete hydrolysis and lower results. In ... GAG are spectrum analysis combined with enzymolysis ... spectrometry (ESI-FTMS), and nuclear magnetic.

  6. Progress of the DUPIC fuel compatibility analysis (I) - reactor physics

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hang Bok; Jeong, Chang Joon; Roh, Gyu Hong; Rhee, Bo Wook; Park, Jee Won

    2003-12-01

    Since 1992, the direct use of spent pressurized water reactor fuel in CANada Deuterium Uranium (CANDU) reactors (DUPIC) has been studied as an alternative to the once-through fuel cycle. The DUPIC fuel cycle study is focused on the technical feasibility analysis, the fabrication of DUPIC fuels for irradiation tests and the demonstration of the DUPIC fuel performance. The feasibility analysis was conducted for the compatibility of the DUPIC fuel with existing CANDU-6 reactors from the viewpoints of reactor physics, reactor safety, fuel cycle economics, etc. This study has summarized the intermediate results of the DUPIC fuel compatibility analysis, which includes the CANDU reactor physics design requirements, DUPIC fuel core physics design method, performance of the DUPIC fuel core, regional overpower trip setpoint, and the CANDU primary shielding. The physics analysis showed that the CANDU-6 reactor can accommodate the DUPIC fuel without deteriorating the physics design requirements by adjusting the fuel management scheme if the fissile content of the DUPIC fuel is tightly controlled.

  7. Progressive-Ratio Schedules and Applied Behavior Analysis

    Science.gov (United States)

    Poling, Alan

    2010-01-01

    Establishing appropriate relations between the basic and applied areas of behavior analysis has been of long and persistent interest to the author. In this article, the author illustrates that there is a direct relation between how hard an organism will work for access to an object or activity, as indexed by the largest ratio completed under a…

  8. Calcium determination in bone by proton activation analysis. Progress report

    International Nuclear Information System (INIS)

    Wilson, R.; Adelstein, S.

    1974-01-01

    The incidence of post-menopausal osteoporosis in almost epidemic proportions makes the early diagnosis and development of effective therapy a matter of considerable concern. Current status of the project is reviewed and new applications of calcium determination by in vivo proton activation analysis are discussed. The proton activation method promises to give precise and reproducible measurements of calcium content for a single vertebra or several vertebrae in vivo. By controlling the number and energy of protons incident on a vertebra and by accurately detecting the number of 2.17 MeV gamma rays emitted, one may determine the 40Ca content. The proton technique offers advantages by directly measuring calcium in a very well-defined region. On-going studies by the construction of a lead shield for in vivo counting and for the analysis of the results are also given

  9. [Progress on Determination and Analysis of Zopiclone in Biological Samples].

    Science.gov (United States)

    Shu, C X; Gong, D; Zhang, L P; Zhao, J X

    2017-12-01

    As a new hypnotic, zopiclone is widely used in clinical treatment. There are many methods for determination of zopiclone, including spectrophotometry, chromatography and chromatography mass spectrum, etc. Present paper reviews different kinds of biological samples associated with zopiclone, extraction and purification methods, and determination and analysis methods, which aims to provide references for the relevant research and practice. Copyright© by the Editorial Department of Journal of Forensic Medicine.

  10. PROGRESS IN SIFT-MS: BREATH ANALYSIS AND OTHER APPLICATIONS

    Czech Academy of Sciences Publication Activity Database

    Španěl, Patrik; Smith, D.

    2011-01-01

    Roč. 30, č. 2 (2011), s. 236-267 ISSN 0277-7037 R&D Projects: GA MPO FT-TA4/124; GA ČR GA202/09/0800; GA ČR GA203/09/0256 Institutional research plan: CEZ:AV0Z40400503 Keywords : SIFT-MS * breath analysis * ion flow tube Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 10.461, year: 2011

  11. Recent progress on HYSPEC, and its polarization analysis capabilities

    Directory of Open Access Journals (Sweden)

    Winn Barry

    2015-01-01

    Full Text Available HYSPEC is a high-intensity, direct-geometry time-of-flight spectrometer at the Spallation Neutron Source, optimized for measurement of excitations in small single-crystal specimens with optional polarization analysis capabilities. The incident neutron beam is monochromated using a Fermi chopper with short, straight blades, and is then vertically focused by Bragg scattering onto the sample position by either a highly oriented pyrolitic graphite (unpolarized or a Heusler (polarized crystal array. Neutrons are detected by a bank of 3He tubes that can be positioned over a wide range of scattering angles about the sample axis. HYSPEC entered the user program in February 2013 for unpolarized experiments, and is already experiencing a vibrant research program. Polarization analysis will be accomplished by using the Heusler crystal array to polarize the incident beam, and either a 3He spin filter or a supermirror wide-angle polarization analyser to analyse the scattered beam. The 3He spin filter employs the spin-exchange optical pumping technique. A 60∘ wide angle 3He cell that matches the detector coverage will be used for polarization analysis. The polarized gas in the post-sample wide angle cell is designed to be periodically and automatically refreshed with an adjustable pressure of polarized gas, optically pumped in a separate cell and then transferred to the wide angle cell. The supermirror analyser has 960 supermirror polarizers distributed over 60∘, and has been characterized at the Swiss Spallation Neutron Source. The current status of the instrument and the development of its polarization analysis capabilities are presented.

  12. Texture and mouthfeel of semi-solid foods : commercial mayonnaises, dressings, custard desserts and warm sauces

    NARCIS (Netherlands)

    Weenen, H.; Gemert, van L.J.; Doorn, van J.M.; Dijksterhuis, G.B.; Wijk, de R.A.

    2003-01-01

    Texture and mouthfeel sensations of three groups of semisolid foodstuffs (mayonnaises and dressings, custard desserts and warm sauces) were characterised, measured, evaluated and compared based on quantitative descriptive sensory analysis of commercial products. Six groups of texture attributes were

  13. Texture and mouthfeel of semisolid foods: Commercial mayonnaises, dressings, custard desserts and warm sauces

    NARCIS (Netherlands)

    Weenen, H.; Gemert, L.J. van; Doorn, J.M. van; Dijksterhuis, G.B.; Wijk, R.A. de

    2003-01-01

    Texture and mouthfeel sensations of three groups of semisolid foodstuffs (mayonnaises and dressings, custard desserts and warm sauces) were characterised, measured, evaluated and compared based on quantitative descriptive sensory analysis of commercial products. Six groups of texture attributes were

  14. TEXTURE OF COOKED SPELT WHEAT NOODLES

    Directory of Open Access Journals (Sweden)

    Magdaléna Lacko - Bartošová

    2013-02-01

    Full Text Available At present, there are limited and incomplete data on the ability of spelt to produce alimentary pasta of suitable quality. Noodles are traditional cereal-based food that is becoming increasingly popular worldwide because of its convenience, nutritional qualities, and palatability. It is generally accepted that texture is the main criterion for assessing overall quality of cooked noodles. We present selected indicators of noodle texture of three spelt cultivars – Oberkulmer Rotkorn, Rubiota and Franckenkorn grown in an ecological system at the locality of Dolna Malanta near Nitra. A texture analyzer TA.XT PLUS was used to determine cooked spelt wheat noodle firmness (N (AACC 66-50. The texture of cooked spelt wheat noodles was expressed also as elasticity (N and extensibility (mm. Statistical analysis showed significant influence of the variety and year of growing on the firmness, elasticity and extensibility of cooked noodles. The wholemeal spelt wheat noodles were characterized with lower cutting firmness than the flour noodles. Flour noodles were more tensile than wholemeal noodles. The best elasticity and extensibility of flour noodles was found in noodles prepared from Rubiota however from wholemeal noodles it was Oberkulmer Rotkorn. Spelt wheat is suitable for noodle production, however also here it is necessary to differentiate between varieties. According to achieved results, wholemeal noodles prepared from Oberkulmer Rotkorn can be recommended for noodle industry due to their consistent structure and better texture quality after cooking.

  15. Hardwood species classification with DWT based hybrid texture ...

    Indian Academy of Sciences (India)

    to decompose the image up to 7 levels using Daubechies (db3) wavelet as decom ... binary pattern (DWTFOSLBPu2) texture features at the 4th level of image decomposi ...... In addition, inclusion of further levels of image decomposition gives rise to ..... Texture analysis of SAR sea ice imagery using gray level co-occurrence.

  16. M-HinTS: Mimicking Humans in Texture Sorting

    NARCIS (Netherlands)

    van den Broek, Egon; Rogowitz, Bernice E.; van Rikxoort, Eva M.; Pappas, Thrasyvoulos N.; Kok, Thijs; Daly, Scott J.; Schouten, Theo E.

    2006-01-01

    Various texture analysis algorithms have been developed the last decades. However, no computational model has arisen that mimics human texture perception adequately. In 2000, Payne, Hepplewhite, and Stoneham and in 2005, Van Rikxoort, Van den Broek, and Schouten achieved mappings between humans and

  17. Quaternion-Based Texture Analysis of Multiband Satellite Images: Application to the Estimation of Aboveground Biomass in the East Region of Cameroon.

    Science.gov (United States)

    Djiongo Kenfack, Cedrigue Boris; Monga, Olivier; Mpong, Serge Moto; Ndoundam, René

    2018-03-01

    Within the last decade, several approaches using quaternion numbers to handle and model multiband images in a holistic manner were introduced. The quaternion Fourier transform can be efficiently used to model texture in multidimensional data such as color images. For practical application, multispectral satellite data appear as a primary source for measuring past trends and monitoring changes in forest carbon stocks. In this work, we propose a texture-color descriptor based on the quaternion Fourier transform to extract relevant information from multiband satellite images. We propose a new multiband image texture model extraction, called FOTO++, in order to address biomass estimation issues. The first stage consists in removing noise from the multispectral data while preserving the edges of canopies. Afterward, color texture descriptors are extracted thanks to a discrete form of the quaternion Fourier transform, and finally the support vector regression method is used to deduce biomass estimation from texture indices. Our texture features are modeled using a vector composed with the radial spectrum coming from the amplitude of the quaternion Fourier transform. We conduct several experiments in order to study the sensitivity of our model to acquisition parameters. We also assess its performance both on synthetic images and on real multispectral images of Cameroonian forest. The results show that our model is more robust to acquisition parameters than the classical Fourier Texture Ordination model (FOTO). Our scheme is also more accurate for aboveground biomass estimation. We stress that a similar methodology could be implemented using quaternion wavelets. These results highlight the potential of the quaternion-based approach to study multispectral satellite images.

  18. Progress of the DUPIC Fuel Compatibility Analysis (IV) - Fuel Performance

    International Nuclear Information System (INIS)

    Choi, Hang Bok; Ryu, Ho Jin; Roh, Gyu Hong; Jeong, Chang Joon; Park, Chang Je; Song, Kee Chan; Lee, Jung Won

    2005-10-01

    This study describes the mechanical compatibility of the direct use of spent pressurized water reactor (PWR) fuel in Canada deuterium uranium (CANDU) reactors (DUPIC) fuel, when it is loaded into a CANDU reactor. The mechanical compatibility can be assessed for the fuel management, primary heat transport system, fuel channel, and the fuel handling system in the reactor core by both the experimental and analytic methods. Because the physical dimensions of the DUPIC fuel bundle adopt the CANDU flexible (CANFLEX) fuel bundle design which has already been demonstrated for a commercial use in CANDU reactors, the experimental compatibility analyses focused on the generation of material property data and the irradiation tests of the DUPIC fuel, which are used for the computational analysis. The intermediate results of the mechanical compatibility analysis have shown that the integrity of the DUPIC fuel is mostly maintained under the high power and high burnup conditions even though some material properties like the thermal conductivity is a little lower compared to the uranium fuel. However it is required to slightly change the current DUPIC fuel design to accommodate the high internal pressure of the fuel element. It is also strongly recommended to perform more irradiation tests of the DUPIC fuel to accumulate a database for the demonstration of the DUPIC fuel performance in the CANDU reactor

  19. Progress of the DUPIC Fuel Compatibility Analysis (IV) - Fuel Performance

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hang Bok; Ryu, Ho Jin; Roh, Gyu Hong; Jeong, Chang Joon; Park, Chang Je; Song, Kee Chan; Lee, Jung Won

    2005-10-15