WorldWideScience

Sample records for tetrofosmin chest images

  1. Tetrofosmin in metastatic breast cancer

    International Nuclear Information System (INIS)

    Berghammer, P.; Obwegeser, R.; Ulm, M.; Wiltschke, C.; Kubista, E.; Sinzinger, H.; Zielinski, C.

    1997-01-01

    Tetrofosmin (1,2-bis[bis(2-ethoxyethyl)phosphino]ethan) is currently under investigation for its tumor seeking properties, encouraged by the incidental finding of a malignant breast-lesion on myocardial scintigraphy in 1995 (Rambaldi et al, Clin Nucl Med 1995) using tetrofosmin. Recent reports have confirmed tetrofosmins role in detecting primary tumors in breast cancer. To investigate whether tetrofosmin significantly helps detect metastatic lesions in such patients we performed tetrofosmin scintigraphy in 21 patients with metastatic breast cancer. Patients and methods: Median age of patients was 61 years. In one patient the primary site was unknown. All patients had at least one distant metastasis. 550 MBq of 99m-Tc-tetrofosmin was administered ten minutes before imaging was begun. After obtaining a planar image, a single photon emission computed tomography (SPECT) was done of every suspected distant lesion. CT-scans or MRI were used to confirm positive correlation with tetrofosmin scintigraphy. Results: Tetrofosmin scintigraphy correctly diagnosed metastatic disease in 71 % of patients with no false negative and two false positive results. In each of the two patients a mediastinal hot spot suggestive of malignancy was found, but none of those lesions could be proven using CT scans. Excluding patients with liver metastasis from the present analysis, 91 % of all metastasis would have been correctly diagnosed. The first patient in our department had a large metastasis in the upper mediastinum which could not be seen on regular chest films. In the patient in whom the primary site of cancer was unknown, tetrofosmin scintigraphy showed three consecutive nodules in the left mammary, gland in a coronary fashion. Magnetic resonance imaging then confirmed two single nodules of 0.8 cm in diameter. Conclusions: Evaluating 21 patients, the present study was performed to investigate tetrofosmins properties of detecting metastatic lesions in patients with breast cancer. A 91

  2. Usefulness of technetium-99m tetrofosmin single-photon emission computed tomography for short-term risk stratification in patients with acute chest pain in the emergency room

    International Nuclear Information System (INIS)

    Kawahito, Michitomo; Kondo, Makoto; Abe, Yoshiteru

    2003-01-01

    High-risk patients with acute coronary syndrome are difficult to distinguish from low-risk patients with chest pain in the emergency room. Technetium-99 m ( 99m Tc) tetrofosmin single-photon emission computed tomography (SPECT) was investigated to exclude high-risk patients with chest pain in the emergency room. 99m Tc-tetrofosmin SPECT was evaluated using a four-point scoring system in 228 patients (144 men, 84 women, mean age 68±12 years) with chest pain. Negative was defined as the myocardial segments with a defect score (DS) of 99m Tc-tetrofosmin; no significance (NS)), 84.9% (NS) and 60.4% (p 99m Tc-tetrofosmin SPECT is a useful method to exclude high-risk patients among patients with chest pain in the emergency room. (author)

  3. A comparative study of 99Tcm-tetrofosmin and 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Zhao Kui; Chen Peng; Zhang Furong; Shen Wenhua

    2001-01-01

    Objective: To evaluate the value of 99 Tc m -tetrofosmin myocardial imaging for detecting coronary artery disease. Methods: Twenty-seven patients underwent 99 Tc m -tetrofosmin SPECT, twenty-six patients underwent 99 Tc m -MIBI SPECT; coronary angiography was performed on patients included in both groups (≥50% luminal diameter stenosis was considered significant coronary stenosis). Results: 99 Tc m -tetrofosmin produced high quality myocardial images from 30 min to several hours postinjection, the outlines of myocardial perfusion images provided by 99 Tc m -tetrofosmin imaging were clearly discernible. One-day exercise/rest 99 Tc m -tetrofosmin myocardial perfusion imaging was feasible and had a high sensitivity for detection of coronary artery disease. Sensitivities of 99 Tc m -tetrofosmin SPECT and 99 Tc m -MIBI SPECT for detecting coronary artery disease were 90% and 94%, respectively. The 95% confidence limits of both sensitivities were 68.65% - 98.77% and 72.33% - 99.86%, respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 72.33% - 99.86% respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 66.38% - 98.70%, respectively; efficiencies of both imaging agents were 85.2% and 88.5%, respectively. The 95% confidence limits of both efficiencies were 65.81% - 95.78% and 69.44 - 98.70%, respectively. The specificity for both imaging agents was 71% and 75%. There was no significant difference among above results (P > 0.05). No ECG abnormalities were found following the injection of 99 Tc m -tetrofosmin SPECT. There were no drug-related effects on blood pressure, heart rate and body temperature. This experiment failed to provide the negative predictive value of the myocardial perfusion imaging with 99 Tc m -tetrofosmin because that few patients with

  4. Tc99m-Tetrofosmin and Thallium-201 SPECT imaging of pituitary tumors: Preliminary results

    International Nuclear Information System (INIS)

    Yarman, S.; Mudun, A.

    2002-01-01

    Aim: It has been reported that pituitary adenomas accumulate Thallium -201(Tl-201), Tc99m-sestamibi and In111-Octreotide. These agents maybe useful in the diagnosis and follow-up of pituitary adenomas. Tc99m-tetrofosmin also has been shown as an tumor seeking agent in various tumors. The aim of this study is to evaluate the accumulation of Tc99m-tetrofosmin in pituitary adenomas and compare the results to Tl-201 SPECT. Methods: We performed Tc99m-Tetrofosmin and Tl-201 SPECT imaging on 5 patients (pts) with pituitary tumors, 3 patients with acromegaly, 1 patient with macro prolactinoma, and 1 patient with nonfunctional tumor (1 female, 4 male, age range: 26-50). SPECT imaging of cranium were obtained 20 min after intravenous injection of 111 MBq Tl-201 and 555 MBq Tc99m-Tetrofosmin on different days with a dual head gamma camera. All but one patient had surgical therapy. One patient had medical treatment. One patient had post surgical imaging with both Tetrofosmin and Tl-201 and 2 pts had only with Thallium. Semiquantitative analysis were performed by calculating tumor to background ratio from the mean counts of the created ROI's. Results: All adenomas showed prominent uptake with both Thallium and Tetrofosmin. The mean tumor to background ratios were 2.3 (range: 1.2-4.29) with Thallium and 3.57 (range: 1.6-6.86) with Tetrofosmin. Post therapy images showed no significant uptake in pituitary region with both agents in 2 patients. Post therapy mean Thallium uptake ratio in 3 pts was 1.64. One patient with acromegaly showed no decrease in thallium uptake, but showed some decrease in tetrofosmin uptake. Conclusion: Although our patient number is limited, these preliminary results indicate that Tc99m-tetrofosmin has also strong affinity for pituitary adenomas as does Thallium, either the adenoma is functioning or non-functioning. It may have a potential value to evaluate the response to therapy

  5. Evaluation of myocardial viability with 99Tcm-tetrofosmin after nitrate administration: comparison with FDG PET imaging

    International Nuclear Information System (INIS)

    He Wei; Cuocolo, A.

    2007-01-01

    Objective: The purpose of this study was to assess the relationship between tetrofosmin uptake after nitrate administration and the metabolic activity assessed by 18 F-FDG PET in patients with ischemic left ventricular (LV) dysfunction. Methods: A baseline 99 Tc m -tetrofosmin SPECT at rest and a repeated study after sublingual administration of 10 mg isosorbide dinitrate within two days were undertaken in 36 patients with chronic myocardial infarction and LV dysfunction. All patients underwent metabolic PET imaging with 18 F-FDG in the following week. 99 Tc m -tetrofosmin uptake and metabolic activity in 13 segments of myocardium were measured in every patient. A 55% peak activity on tetrofosmin and 50% peak activity on FDG were used as the differential threshold in evaluating myocardial viability, and the uptakes compared with regional LV function assessed by echocardiography. Results: Fifty-three (40%) of the 131 akinetic or dyskinetic segments had reduced tracer uptake. Of those segments, 14 (26%) segments showed increased tetrofosmin uptake after nitrate intervention (>10% vs baseline), 39 (74%) segments remained no change. The sensitivity and specificity of baseline tetrofosmin SPECT for detecting preserved metabolic activity were 69% and 86%, respectively. After nitrate administration, the sensitivity increased to 81% (P 99 Tc m -tetrofosmin SPECT after nitrate administration may improve the identification of ischemic but still viable myocardium in patients with chronic ischemic LV dysfunction. (authors)

  6. Learning chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pedrozo Pupo, John C. (ed.) [Magdalena Univ., Santa Maria (Colombia). Respire - Inst. for Respiratory Care

    2013-03-01

    Useful learning tool for practitioners and students. Overview of the imaging techniques used in chest radiology. Aid to the correct interpretation of chest X-ray images. Radiology of the thorax forms an indispensable element of the basic diagnostic process for many conditions and is of key importance in a variety of medical disciplines. This user-friendly book provides an overview of the imaging techniques used in chest radiology and presents numerous instructive case-based images with accompanying explanatory text. A wide range of clinical conditions and circumstances are covered with the aim of enabling the reader to confidently interpret chest images by correctly identifying structures of interest and the causes of abnormalities. This book, which will be an invaluable learning tool, forms part of the Learning Imaging series for medical students, residents, less experienced radiologists, and other medical staff. Learning Imaging is a unique case-based series for those in professional education in general and for physicians in prarticular.

  7. Technetium-99m tetrofosmin imaging in thyroid diseases: comparison with Tc-99m-pertechnetate, thallium-201 and Tc-99m-methoxyisobutylisonitrile scans

    International Nuclear Information System (INIS)

    Klain, M.; Cuocolo, A.; Marzano, L.; Lombardi, G.; Salvatore, M.; Univ. di Napoli

    1996-01-01

    In this study, tetrofosmin whole-body scintigraphy was performed in 35 patients with evidence of thyroid diseases. All patients underwent laboratory evaluation of thyroid function as well as 99m Tc pertechnetate scan, thallium-201 99m Tc-methoxyisobutylisonitrile (MIBI) whole-body studies. Thyroid images were semi-quantitatively analysed by a 4-point score: 0=no significant uptake; 1=uptake increased but inferior to normal thyroid tissue; 2=uptake equal to normal thyroid tissue; 3=uptake superior to normal thyroid tissue. A total of 41 thyroid nodules were detected, of which 15 were goitre nodules, 13 adenomas and 13 malignant lesions. In goitre nodules, concordant results of tetrofosmin and pertechnetate uptake (score 1 or 0) were observed in the majority of lesions (87%). In function adenomas both tetrofosmin uptake and pertechnetate uptake were score 3. In non-function adenomas tetrofosmin uptake was score 3, while pertechnetate uptake was score 0. In six malignant lesions, tetrofosmin uptake was score 3, while pertechnetate uptake was score 0; in the other seven lesions, where a prevalence of goitre abnormalities was observed, results of tetrofosmin and pertechnetate uptake were similar (score 0 or 1). In (70%) patients with malignant nodules, whole-body tetrofosmin images showed increased abnormal uptake in a total of 28 extra-thyroid tumour sites, as subsequently confirmed by other techniques. When tetrofosmin images were compared to 201 Tl and 99m Tc-MIBI scans, concordant results were observed in all cases. In conclusion, tetrofosmin imaging may be particularly useful to characterize and stage patients with malignant thyroid nodules; it shows similar results to thallium but provides better image quality. Comparable findings were observed between tetrofosmin and MIBI studies. Thus, tetrofosmin may be an alternative to thallium and MIBI in the aforementioned patients. (orig.). With 4 figs., 3 tabs

  8. Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands

    International Nuclear Information System (INIS)

    Giordano, A.; Meduri, G.; Calcagni, M.L.; Marozzi, P.; Ficola, U.; Vaccaro, A.; Rubini, G.; Attard, M.; Li Puma, M.; Ricci, R.; Corsello, S.

    1999-01-01

    The aim of the study was to quantitatively compare the scintigraphic images of the thyroid and abnormal parathyroid glands obtained with technetium-99m tetrofosmin and thallium-201 in patients with hyperparathyroidism. Forty-six patients with hyperparathyroidism underwent 201 Tl (74 MBq), 99m Tc-pertechnetate (74 MBq) and 99m Tc-tetrofosmin (555-740 MBq) scintigraphy in a single session. Image analysis included the computation of the thyroid/background ratio in the whole study population and the parathyroid/background ratio, parathyroid/thyroid ratio and diagnostic sensitivity in 17 patients who underwent parathyroid surgery. The pertechnetate subtraction technique was used. 201 Tl and 99m Tc-tetrofosmin showed a similar thyroid/background ratio (1.79±0.41 and 1.81±0.47, respectively, P=NS); however, 99m Tc-tetrofosmin showed a higher parathyroid/background ratio than 201 Tl (2.06±0.54 vs 1.79± 0.50, P=0.007). Despite the superior quality of 99m Tc-tetrofosmin images, both tracers showed identical sensitivity in detecting enlarged parathyroid glands in patients with primary hyperparathyroidism (89%) and in those with secondary hyperparathyroidism (50%). (orig.)

  9. Pediatric digital chest imaging.

    Science.gov (United States)

    Tarver, R D; Cohen, M; Broderick, N J; Conces, D J

    1990-01-01

    The Philips Computed Radiography system performs well with pediatric portable chest radiographs, handling the throughout of a busy intensive care service 24 hours a day. Images are excellent and routinely provide a conventional (unenhanced) image and an edge-enhanced image. Radiation dose is decreased by the lowered frequency of repeat examinations and the ability of the plates to respond to a much lower dose and still provide an adequate image. The high quality and uniform density of serial PCR portable radiographs greatly enhances diagnostic content of the films. Decreased resolution has not been a problem clinically. Image manipulation and electronic transfer to remote viewing stations appear to be helpful and are currently being evaluated further. The PCR system provides a marked improvement in pediatric portable chest radiology.

  10. Pediatric digital chest imaging

    International Nuclear Information System (INIS)

    Tarver, R.D.; Cohen, M.; Broderick, N.J.; Conces, D.J. Jr.

    1990-01-01

    The Philips Computed Radiography system performs well with pediatric portable chest radiographs, handling the throughout of a busy intensive care service 24 hours a day. Images are excellent and routinely provide a conventional (unenhanced) image and an edge-enhanced image. Radiation dose is decreased by the lowered frequency of repeat examinations and the ability of the plates to respond to a much lower dose and still provide an adequate image. The high quality and uniform density of serial PCR portable radiographs greatly enhances diagnostic content of the films. Decreased resolution has not been a problem clinically. Image manipulation and electronic transfer to remote viewing stations appear to be helpful and are currently being evaluated further. The PCR system provides a marked improvement in pediatric portable chest radiology

  11. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    Science.gov (United States)

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS SSS >9 were compared to patients with SSS SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  12. Nuclear imaging of the chest

    International Nuclear Information System (INIS)

    Bahk, Y.W.

    1998-01-01

    This book provides up-to-the minute information on the diagnostic nuclear imaging of chest disorders. The authors have endeavored to integrate and consolidate the many different subspecialities in order to enable a holistic understanding of chest diseases from the nuclear medicine standpoint. Highlights of the book include in addition to the cardiac scan the description of aerosol lung imaging in COPD and other important pulmonary diseases and the updates on breast and lung cancer imaging, as well as imaging of the bony thorax and esophagus. It is required reading not only for nuclear medicine practitioners and researchers but also for all interested radiologists, traumatologists, pulmonologists, oncologists and cardiologists. (orig.)

  13. Imaging of chest wall infections

    International Nuclear Information System (INIS)

    Chelli Bouaziz, Mouna; Jelassi, Helmi; Chaabane, Skander; Ladeb, Mohamed Fethi; Ben Miled-Mrad, Khaoula

    2009-01-01

    A wide variety of infections can affect the chest wall including pyogenic, tuberculous, fungal, and some other unusual infections. These potentially life-threatening disorders are frequent especially among immunocompromised patients but often misdiagnosed by physical examination and radiographs. The purpose of this article is to describe the clinical and imaging features of these different chest wall infections according to the different imaging modalities with emphasis on ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI). The outcome of chest wall infection depends on early diagnosis, severity of the immunosuppression, offending organism, and extent of infection. Because clinical findings and laboratory tests may be not contributive in immunocompromised patients, imaging plays an important role in the early detection and precise assessment of the disease. US, CT, and MRI are all useful: bone destruction is more accurately detected with CT whereas soft tissue involvement are better visualized with US and MRI. CT and US are also used to guide percutaneous biopsy and drainage procedures. MR images are helpful in pre-operative planning of extensive chest wall infections. (orig.)

  14. 99Tcm-tetrofosmin myocardial perfusion imaging for diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Zhang Lele; Tian Wei; Shao Guoqiang; Zhang Hang; You Wei; Meng Qingle; Yang Rui; Cao Yan; Wang Xiaowen; Wang Feng

    2012-01-01

    Objective: To assess the clinical value of 99 Tc m -tetrofosmin (TF) MPI for diagnosis of CHD. Methods: A total of 73 patients (46 males,27 females; age: (61.16 ± 12.95) y) were included in this study. 99 Tc m -TF MPI and CAG were performed in all patients. Two-day protocol of MPI was used in this study, with rest MPI performed on the first day and stress (exercise stress or adenosine stress) imaging on the next day. CAG was performed within one week after MPI and served as the gold standard in diagnosis of CHD. Stenosis over 50% of the lumen was considered positive. The diagnostic efficacy of 99 Tc m -TF MPI was evaluated based on the results of CAG. Results: Among the 73 patients,43 patients were CAG positive, 27 cases with single vessel disease, 10 patients with double vessel disease and 6 patients with triple vessel disease. There were 37 patients with abnormality in MPI and 36 patients with normal MPI. Out of 43 patients with positive CAG, there were 32 cases diagnosed with myocardial ischemia and 11 with normal results in MPI. Among the 65 diseased vessels,there were 33 involved in LAD, 16 LCX and 16 RCA. The sensitivity,specificity, positive predictive value,negative predictive value and accuracy of MPI for detection of CHD were 74.4% (32/43), 83.3% (25/30), 86.5% (32/37), 69.4% (25/36) and 78.1% (57/73), respectively. The sensitivities for detection of single vessel disease, double vessel disease and triple vessel disease were 66.7% (18/27), 80.0% (8/10) and 5/6, respectively. The sensitivity and specificity of MPI for detection of coronary disease in all 219 vessels were 67.7% (44/65) and 89.0% (137/154), respectively. Conclusion: 99 Tc m -TF MPI, with convenient preparation and reliable properties of the tracer, may provide an alternative modality for accurate detection of CHD. (authors)

  15. Assessment of area at risk and efficacy of treatment in patients with acute coronary syndrome using 99Tc tetrofosmin imaging in humans

    International Nuclear Information System (INIS)

    Matsuo, Hitoshi; Watanabe, Sachiro; Nishida, Yoshio

    1993-01-01

    The determination of the myocardium at risk before intervention and the change in that region after intervention constitute a promising measurement tool for the assessment of acute therapy. A new 99m Tc labeled myocardial blood flow tracer, 99m Tc tetrofosmin, is expected to enable the evaluation of myocardium at risk because of the absence of redistribution. This preliminary study was performed in 9 patients with acute coronary syndrome (4 unstable angina and 5 acute myocardial infarction) to investigate whether recovery of perfusion by tetrofosmin imaging parallels mechanical improvement. Tetrofosmin imaging was performed acutely and 3-30 days later. Visual analysis of defect severity was assessed in both studies. Segments with improvement in perfusion were accompanied by significant wall motion recovery compared with normal and unimproved segments (ΔWMI: normal segments 0.40±0.67, improved segments 1.79±0.68, unimproved segments -0.15±0.16, p 99m Tc tetrofosmin imaging is a useful method for the assessment of the myocardial area at risk and the efficacy of acute therapy in acute myocardial infarction and unstable angina. (author)

  16. Imaging of fetal chest masses

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Richard A. [Lucile Packard Children' s Hospital, Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2012-01-15

    Prenatal imaging with high-resolution US and rapid acquisition MRI plays a key role in the accurate diagnosis of congenital chest masses. Imaging has enhanced our understanding of the natural history of fetal lung masses, allowing for accurate prediction of outcome, parental counseling, and planning of pregnancy and newborn management. This paper will focus on congenital bronchopulmonary malformations, which account for the vast majority of primary lung masses in the fetus. In addition, anomalies that mimic masses and less common causes of lung masses will be discussed. (orig.)

  17. Chest tube insertion - series (image)

    Science.gov (United States)

    Chest tubes are inserted to drain blood, fluid, or air and allow full expansion of the lungs. The tube is placed in the pleural space. The area where the tube will be inserted is numbed (local anesthesia). The patient may also be sedated. The chest ...

  18. Imaging of blunt chest trauma

    International Nuclear Information System (INIS)

    Prosch, H.; Negrin, L.

    2014-01-01

    Blunt chest trauma is associated with high morbidity and mortality. Consequently, all patients should be evaluated radiologically after blunt chest trauma to allow timely and appropriate treatment. Conventional chest radiographs and computed tomography (CT) are proven modalities with which to evaluate patients after blunt chest trauma. Over the last several years extended focused assessment with sonography for trauma (eFAST) has gained increasing importance for the initial assessment of seriously injured patients. In the acute phase of severely injured patients eFAST examinations are helpful to exclude pneumothorax, hemothorax and hemopericardium. Chest radiographs may also be used to diagnose a pneumothorax or hemothorax; however, the sensitivity is limited and CT is the diagnostic modality of choice to evaluate severely injured patients. (orig.) [de

  19. Imaging of blunt chest trauma

    International Nuclear Information System (INIS)

    Wicky, S.; Wintermark, M.; Schnyder, P.; Capasso, P.; Denys, A.

    2000-01-01

    In western European countries most blunt chest traumas are associated with motor vehicle and sport-related accidents. In Switzerland, 39 of 10,000 inhabitants were involved and severely injured in road accidents in 1998. Fifty two percent of them suffered from blunt chest trauma. According to the Swiss Federal Office of Statistics, traumas represented in men the fourth major cause of death (4 %) after cardiovascular disease (38 %), cancer (28 %), and respiratory disease (7 %) in 1998. The outcome of chest trauma patients is determined mainly by the severity of the lesions, the prompt appropriate treatment delivered on the scene of the accident, the time needed to transport the patient to a trauma center, and the immediate recognition of the lesions by a trained emergency team. Other determining factors include age as well as coexisting cardiac, pulmonary, and renal diseases. Our purpose was to review the wide spectrum of pathologies related to blunt chest trauma involving the chest wall, pleura, lungs, trachea and bronchi, aorta, aortic arch vessels, and diaphragm. A particular focus on the diagnostic impact of CT is demonstrated. (orig.)

  20. Usefulness of combination post-stress dysfunction and perfusion imaging in technetium-99m-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Yamazaki, Yoko; Imai, Kamon; Konaka, Ryohei; Nakajima, Takatomo; Goto, Sayaka; Horie, Toshinobu; Saito, Satoshi; Ozawa, Yukio; Kanmatsuse, Katsuo

    2001-01-01

    Myocardial perfusion imaging has lower sensitivity for the diagnosis of coronary artery disease in patients with three-vessel disease. The presence of post-stress dysfunction of the left ventricle, evaluated by electrocardiography (ECG) gated single photon emission computed tomography (SPECT) with a quantitative gated SPECT program, was investigated in patients with coronary artery disease, and also whether combining post-stress dysfunction and myocardial perfusion imaging improved the diagnosis of coronary artery disease. ECG gated technetium-99m-tetrofosmin SPECT was performed using a one day, stress and rest, protocol in 139 patients. SPECT and coronary angiography were performed within 1 month. The coronary artery disease group consisted of 89 patients: 43 with one-vessel disease (1VD), 28 with two-vessel disease (2VD), and 18 with three-vessel disease (3VD). The group with zero-vessel disease (0VD) consisted of 50 patients. According to post-stress and rest ejection fraction (EF) and end-systolic volume (ESV), post-stress dysfunction is defined as follows: rest EF - post-stress EF≥5% and post-stress ESV - rest ESV≥5ml. In the coronary artery disease group, post-stress ESV was larger than rest ESV (37.8±26.4, 34.0±24.2 ml, p<0.001), and post-stress EF was lower than rest EF (61.5±11.1%, 64.2±10.8%, p<0.001). In the 0VD group, ESV and EF were the same for post-stress and rest (25.7±20.8, 26.2±21.6 ml, NS; 70.4±9.5%, 70.0±9.6%, NS). Post-stress dysfunction was 6.0% in the 0VD group and 30.3% in the coronary artery disease group (p<0.001). Furthermore, post-stress dysfunction in the 2VD (35.7%) and 3VD (38.9%) groups was higher than that in the 0VD group (p<0.01, p<0.01). Sensitivity of coronary artery disease diagnosis by myocardial perfusion imaging was 75%. The combination of post-stress dysfunction and myocardial perfusion imaging improved sensitivity from 75% to 82% (p<0.05), but reduced the specificity from 92% to 86% (p=0.08). Post

  1. Myocardial imaging with 99mTc-Tetrofosmin: Influence of post-stress acquisition time, regional radiotracer uptake, and wall motion abnormalities on the clinical result.

    Science.gov (United States)

    Giorgetti, Assuero; Kusch, Annette; Casagranda, Mirta; Tagliavia, Irene D'Aragona; Marzullo, Paolo

    2010-04-01

    We previously demonstrated that early (15', T1) post-stress myocardial imaging with Tetrofosmin could be more accurate than standard acquisitions (45', T2) in identifying coronary artery disease. To clarify this phenomenon, 120 subjects (age 61 +/- 10 years) with both T1 and T2 scans were divided into Group 1 (53/120 pts) with more ischemia at T1 vs T2 imaging (T1-T2SDS > or = 3); Group 2 (67/120 pts) with similar results (T1-T2SDS statistic and semiquantitative wall motion/thickening values were obtained. Analysis of T1 and T2 post-stress myocardial counts demonstrated a significant Tetrofosmin wash-out rate that was higher in Group 1 control nonischemic regions (15 +/- 8% vs 13.6 +/- 9.6%, P stress wall thickening (T1-T2) was lower in Group 1 ischemic regions (-4.5 +/- 9.15% vs -1.90 +/- 7.0%, P stress acquisition time because of ischemic-induced regional wall thickening abnormalities and the existence of a differential radiotracer myocardial wash-out.

  2. Pediatric chest imaging. Chest imaging in infants and children. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Lucaya, Javier [Vall d' Hebron Hospitals, Barcelona (Spain). Dept. of Pediatric Radiology and Inst. of Diagnostic Imaging; Hospital Quiron, Barcelona (Spain). Dept. of Radiology; Strife, Janet L. (eds.) [Cincinnati Univ. Coll. of Medicine, Cincinnati, OH (United States). Dept. of Radiology Cincinnati Children' s Hospital Medical Center

    2008-07-01

    Imaging of the pediatric chest continues to evolve rapidly. All chapters in this 2nd edition of Pediatric Chest Imaging have been extensively updated, with additional disease-specific information and numerous new illustrations. The book thus presents the state of the art in the diagnosis of pediatric chest disorders, highlighting the role played by advanced technology. As the conventional features of most of these disorders are extremely well known, special attention is devoted to the technical aspects of the modern imaging modalities, their indications, and the diagnostic information that they supply. Individual chapters focus on chest ultrasound, nuclear medicine imaging, high-resolution chest CT, helical CT, and pediatric cardiac CT and pediatric cardiacMRI. Others are directed towards specific disorders, including congenital malformations of the chest, chest tumors, pulmonary infection, trauma, the lung in systemic diseases, the pediatric airway, foreign bodies, the thymus, and the chest wall. Without exception, the authors of this book are internationally known specialists with great expertise in the field. This book will serve as a handy, superbly illustrated reference for all who routinely image children, as well as for those who need access to information on how best to image them. (orig.)

  3. Clinical efficacy of 99mTc-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Adachi, Itaru; Sugioka, Yasushi; Tanaka, Yasunori

    1993-01-01

    99m Tc-tetrofosmin is a lipophilic, cationic diphosphine which has been developed for myocardial imaging. We examined 9 patients with ischemic heart disease including 3 angina pectoris (AP), 4 old myocardial infarction (OMI), 1 AP with OMI and 1 syndrome X. One patient was examined before and after operation. Three hundred seventy MBq of 99m Tc-tetrofosmin was injected during exercise and 740 MBq at rest. And 74 MBq of 201 Tl myocardial exercise and redistribution scintigraphy was also performed to compare with 99m Tc-tetrofosmin myocardial scintigraphy. SPECT, multiple gated SPECT and anterior planar images were obtained in all cases. We calculated percent wall thickening (%WT) using multiple gated SPECT images. There was a decreased lung uptake in 99m Tc-tetrofosmin planar images compared to 201 Tl myocardial scintigraphy. Liver and Biliary system uptake in 99m Tc-tetrofosmin images was decreased with intake of milk. Segmental comparison of SPECT images showed an agreement in 9/10 of the segment between 201 Tl and 99m Tc-tetrofosmin. We could obtain excellent quality of multiple gated SPECT images in all patients. We could calculate percent wall thickening (%WT) in all patients. We conclude that 99m Tc-tetrofosmin myocardial scintigraphy should provide usefulness for detection of ischemic myocardium as same as 201 Tl myocardial scintigraphy, although the biologic characteristics of two agents were different. These data and excellent quality of multiple gated SPECT images suggest that 99m Tc-tetrofosmin is a new 99m Tc agent for evaluation of patients with ischemic heart disease. (author)

  4. Image processing in digital chest radiography

    International Nuclear Information System (INIS)

    Manninen, H.; Partanen, K.; Lehtovirta, J.; Matsi, P.; Soimakallio, S.

    1992-01-01

    The usefulness of digital image processing of chest radiographs was evaluated in a clinical study. In 54 patients, chest radiographs in the posteroanterior projection were obtained by both 14 inch digital image intensifier equipment and the conventional screen-film technique. The digital radiographs (512x512 image format) viewed on a 625 line monitor were processed in 3 different ways: 1.standard display; 2.digital edge enhancement for the standard display; 3.inverse intensity display. The radiographs were interpreted independently by 3 radiologists. Diagnoses were confirmed by CT, follow-up radiographs and clinical records. Chest abnormalities of the films analyzed included 21 primary lung tumors, 44 pulmonary nodules, 16 cases with mediastinal disease, 17 with pneumonia /atelectasis. Interstitial lung disease, pleural plaques, and pulmonary emphysema were found in 30, 18 and 19 cases respectively. Sensitivity of conventional radiography when averaged overall findings was better than that of digital techniques (P<0.001). Differences in diagnostic accuracy measured by sensitivity and specificity between the 3 digital display modes were small. Standard image display showed better sensitivity for pulmonary nodules (0.74 vs 0.66; P<0.05) but poorer specificity for pulmonary emphysema (0.85 vs 0.93; P<0.05) compared with inverse intensity display. It is concluded that when using 512x512 image format, the routine use of digital edge enhancement and tone reversal at digital chest radiographs is not warranted. (author). 12 refs.; 4 figs.; 2 tabs

  5. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    International Nuclear Information System (INIS)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung; Ho, Shung-Tai

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  6. Quality of intensive care chest imaging

    International Nuclear Information System (INIS)

    Adam, G.; Wein, B.; Keulers, P.; Stargardt, A.; Guenther, R.W.

    1989-01-01

    The authors have evaluated the image quality of a stimulable phosphorous plate system in intensive care chest radiography. Four radiologists examined 308 chest radiographs (200 conventional, 108 digital) according to the following criteria: visibility of catheters, tubes (artificial objects), bronchi, central and peripheral vessels, diaphragm, trachea, and retrocardial lung parenchyma. Detectability of these structures was classified as good, poor, or impossible to see. In addition, optical density was measured in the region of liver, heart, and lung. Results were evaluated by Student and υ test

  7. Clinical Significance of Reverse Redistribution Phenomenon on Delayed Tc-99m Tetrofosmin Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction

    International Nuclear Information System (INIS)

    Park, Soon Ah; Kim, Dae Weung; Kim, Chang Guhn; Jeong, Jin Won; Kim, Nam Ho; Yun, Kyeong Ho

    2009-01-01

    This study was performed to investigate the clinical significance of reverse redistribution (RR) phenomenon detected on delayed Tc-99m tetrofosmin myocardial single photon emission computed tomography (SPECT) in patients with acute myocardial infarction after revascularization. A Tc-99m tetrofrosmin myocardial SPECT was performed in 67 consecutive patients after revascularization for acute myocardial infarction. Myocardial SPECT imaging was performed for early imaging at 40 min and for delayed imaging at 180 min after reinjection at myocardial stress. Regional myocardial uptakes were scored by 4-point scoring in the left ventricular wall divided into 17 segments. Reverse redistribution was defined as an increase of more than 2 point in the activity score on the delayed image. Follow-up myocardial SPECT and coronary angiography (CAG) were performed 9 months later. On myocardial SPECT performed following revascularization, RR was observed in 100 of all 319 segments (31%) and in 43 patients (64%). The abnormalities of perfusion and regional wall motion were more severe in the patients with RR compared to those without RR (p<0.05). On follow-up myocardial SPECT, the myocardial perfusion, regional wall motion, and myocardial thickness were significantly improved in the patients with RR (p<0.05) however, these changes were not significant in those without RR. There was no significant difference between the patients with RR and those without RR in the occurrence of restenosis on CAG. In patients with acute myocardial infarction, the regions showing the RR phenomenon on delayed Tc-99m tetrofosmin SPECT may reflect viable myocardium and indicate recovery of salvaged myocardium

  8. Effect of Temperature and Mole Ratio on the Synthesis Yield of Rhenium-Tetrofosmin

    Directory of Open Access Journals (Sweden)

    Widyastuti

    2015-08-01

    Full Text Available Technetium-99m (99mTc tetrofosmin is widely used in nuclear medicine as a diagnostic agent for myocardial perfusion and as a tumor imaging agent. As a parenteral preparation it requires an evaluation of its pharmacokinetics and stability in-vivo. Since 99mTc has a short half-life and is only available in very low concentrations, it is impossible to characterize its chemical properties and presence in the body. Due to this reason, only technetium-99 (T1/2 = 5 × 105 years, which is available in macro quantities, or natural rhenium can be used for this purpose. In this study rhenium-188 (188Re tetrofosmin will be synthesized and applied, because non-radioactive Re can be easily obtained. Synthesis and radiochemical purity analysis of carrier-added 188Re-tetrofosmin were carried out as a model to study the in-vivo stability of technetium-99m tetrofosmin. Rhenium-188 was used as a tracer to identify the formation of rhenium tetrofosmin. Rhenium gluconate was synthesized first prior to the formation of rhenium tetrofosmin. The quality of labeling for both rhenium gluconate and rhenium tetrofosmin was analyzed using paper- and thin-layer chromatography, respectively. Rhenium gluconate can be synthesized with high labeling yield within 1 hour, whereas rhenium tetrofosmin was synthesized both in room temperature and in an elevated temperature with various tetrofosmin-to-rhenium mole ratios.The results showed that heating at 95oC led to a higher yield of more than 90% within 30 minutes. Rhenium tetrofosmin could be produced in high radiochemical purity using an excess of tetrofosmin with mole ratio of 2000. It is concluded that rhenium tetrofosmin could be synthesized through the formation of rhenium gluconate, and a higher yield could be obtained in a shorter time by heating process.

  9. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  10. Chest magnetic resonance imaging: a protocol suggestion

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-12-01

    Full Text Available Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.

  11. Chest tuberculosis: Radiological review and imaging recommendations

    International Nuclear Information System (INIS)

    Bhalla, Ashu Seith; Goyal, Ankur; Guleria, Randeep; Gupta, Arun Kumar

    2015-01-01

    Chest tuberculosis (CTB) is a widespread problem, especially in our country where it is one of the leading causes of mortality. The article reviews the imaging findings in CTB on various modalities. We also attempt to categorize the findings into those definitive for active TB, indeterminate for disease activity, and those indicating healed TB. Though various radiological modalities are widely used in evaluation of such patients, no imaging guidelines exist for the use of these modalities in diagnosis and follow-up. Consequently, imaging is not optimally utilized and patients are often unnecessarily subjected to repeated CT examinations, which is undesirable. Based on the available literature and our experience, we propose certain recommendations delineating the role of imaging in the diagnosis and follow-up of such patients. The authors recognize that this is an evolving field and there may be future revisions depending on emergence of new evidence

  12. Relationship between lung-to-heart uptake ratio of technetium-99m-tetrofosmin during exercise myocardial single photon emission computed tomographic imaging and the number of diseased coronary arteries in patients with effort angina pectoris without myocardial infarction

    International Nuclear Information System (INIS)

    Okajima, Toshiya; Ueshima, Kenji; Nishiyama, Osamu; Ogawa, Muneyoshi; Ohuchi, Mami; Saitoh, Masahiko; Hiramori, Katsuhiko

    2004-01-01

    Increased lung uptake of thallium-201 in exercise myocardial perfusion imaging is a reliable marker of multivessel disease in patients with ischemic heart disease. This study investigated whether the lung-to-heart uptake ratio with technetium-99m ( 99m Tc)-tetrofosmin also provides valuable information to detect patients with multivessel disease. Fifty-three consecutive patients (35 men, 18 women, mean age 66±11 years; single-vessel disease: 29, double-vessel disease: 16, triple-vessel disease: 8) with stable effort angina pectoris without prior myocardial infarction and 17 control subjects (12 men, 5 women, mean age 62±9 years) underwent exercise myocardial perfusion imaging with 99m Tc-tetrofosmin and coronary angiography in January 2000 to December 2002. The lung-to-heart uptake ratio was calculated on an anterior projection before reconstruction of the exercise single photon emission computed tomographic images. The mean lung-to-heart uptake ratio was 0.34±0.04, 0.38±0.07, 0.41±0.05, and 0.46±0.09, in patients with normal coronary, single-vessel disease, double-vessel disease, and triple-vessel disease, respectively. Significantly higher lung-to-heart uptake ratio was associated with more diseased vessels (p 99m Tc-tetrofosmin can provide clinically useful information to detect multivessel disease in patients with ischemic heart disease. (author)

  13. Chest trauma in children: current imaging guidelines and techniques.

    LENUS (Irish Health Repository)

    Moore, Michael A

    2011-09-01

    Given the heterogeneous nature of pediatric chest trauma, the optimal imaging approach is tailored to the specific patient. Chest radiography remains the most important imaging modality for initial triage. The decision to perform a chest computed tomography scan should be based on the nature of the trauma, the child\\'s clinical condition, and the initial radiographic findings, taking the age-related pretest probabilities of serious injury into account. The principles of as low as reasonably achievable and Image Gently should be followed. The epidemiology and pathophysiology, imaging techniques, characteristic findings, and evidence-based algorithms for pediatric chest trauma are discussed.

  14. Technetium-99m-tetrofosmin in diagnosis of breast cancer and axillary lymph node involvement

    International Nuclear Information System (INIS)

    Jaukovic, Dj.; Ajdinovic, B.Z.; Jankovic, Z. D.; Strbac, M.

    2006-01-01

    The aim of this study was to evaluate the accuracy of breast cancer seeking agent Tc-99m-Tetrofosmin in the detection of breast malignancy and axillary lymph node metastases. Twenty-eight female patients (mean age 52.4) with 30 breast lesions suspected of malignancy were enrolled in the study. All the patients underwent clinical investigation, Tc-99m Tetrofosmin scintimammography (SMM), mammography (MM) and biopsy/surgery for final histopathologic diagnosis. Patients were injected intravenously with 555 MBq of Tc-99m Tetrofosmin, cubitally, in the contralateral arm to the side of suspicious lesion. Seven minute static scans or at least 2.0 million counts were obtained using single head gamma camera (Orbiter 75, Siemens). Planar images were acquired in left and right prone lateral view as well as in the supine position for an anterior view of chest and axillary region. SMM scans of 30 breast lesions were compared to the definitive histopathology findings (HP) using decision matrix. In the group of 23 patients with positive SMM scans 19 had breast malignancy: 15 infiltrating ductal cancer, three patients with one infiltrating lobular, one papillary, one colloidal cancer and one patient with cystosarcoma phyllodes-malignant type. SMM detected primary breast malignancy with 95% sensitivity, 60% specificity and 83% accuracy. Axillary dissection was performed in 19/20 with malignant disease. The number of lymph nodes extracted and HP evaluated varied from 4 to 23 per patient. Metastatic involvement was confirmed by HP in 9 out of 20 patients. SMM detected axillary metastases with 55% sensitivity and 80% accuracy. Our results showed that SMM might be useful as a complementary test to improve the sensitivity and specificity of conventional imaging modalities, although SMM in the staging of breast carcinoma was less reliable. Further studies to evaluate the role of SMM in metastatic node involvement are necessary. (author)

  15. Imaging recognition of inhibition of multidrug resistance in human breast cancer xenografts using 99mTc-labeled sestamibi and tetrofosmin

    International Nuclear Information System (INIS)

    Liu Zhonglin; Stevenson, Gail D.; Barrett, Harrison H.; Furenlid, Lars R.; Wilson, Donald W.; Kastis, George A.; Bettan, Michael; Woolfenden, James M.

    2005-01-01

    Background: 99m Tc-sestamibi (MIBI) and 99m Tc-tetrofosmin (TF) are avid transport substrates recognized by the multidrug resistance (MDR) P-glycoprotein (Pgp). This study was designed to compare the properties of MIBI and TF in assessing the inhibition of Pgp by PSC833 in severe combined immunodeficient mice bearing MCF7 human breast tumors using SPECT imaging. Methods: Animals with drug-sensitive (MCF/WT) and drug-resistant (MCF7/AdrR) tumors were treated by PSC833 and by carrier vehicle 1 h before imaging, respectively. Dynamic images were acquired for 30 min after intravenous injection of MIBI/TF using a SPECT system, FastSPECT. The biodistribution of MIBI and TF was determined at the end of the imaging session. Results: MCF7/WT in the absence and presence of PSC833 could be visualized by MIBI and TF imaging within 5 min and remained detectable for 30 min postinjection. MCF7/AdrR could be visualized only 2-5 min without PSC833 treatment but could be detected for 30 min with PSC833, very similar to MCF7/WT. MCF7/AdrR without PSC833 showed significantly greater radioactive washout than MCF7/WT and MCF7/AdrR with PSC833 treatment. PSC833 increased the accumulation (%ID/g) in MCF7/AdrR 3.0-fold (1.62±0.15 vs. 0.55±0.05, P<.05) for TF and 1.9-fold (1.21±0.04 vs. 0.64±0.05, P<.05) for MIBI but did not affect MCF7/WT. Conclusions: The feasibility of MIBI and TF for assessment of MDR expression and inhibition was demonstrated in mice through FastSPECT imaging. The results indicate that TF may be at least comparable with MIBI in recognizing Pgp expression and modulation

  16. Uji Stabilitas Kit Cair Tetrofosmin pada Berbagai Kondisi Penyimpanan

    Directory of Open Access Journals (Sweden)

    Yunilda Yunilda

    2016-09-01

    Full Text Available Tetrofosmin radiopharmaceutical compound that is being developed by PTRR BATAN for use as myocardial perfusion imaging agent and cancer diagnostic agent in nuclear medicine. The aim of this study is observe the stability of this liquid kits after stored in various condition to determine its expire date various condition. The stability test was done of 1 hour, 3 hours, 5 hours and 7 hours after labeling. The radiochemical was determined its radiochemical purity has to be ≥ 90 %. Analysis of radiochemical purity was carried out by separation method which using Sep-Pak C18 cartride. Storage condition of tetrofosmin kit was carried out at various temperatures as in the deep freezer (-800C, freezer (-180C, refrigerator (2-60C and cool box (2-60C. The result showed that the liquid tetrofosmin kits stored in deep freezer, freezer, refrigerator were stable up to 23 months, 8 weeks and 4 days respectively. Simulation of stability  test after stored in a cool box was done by observing the temperature of cool box, and the result showed that the temperature in the cool box was constant as in refrigerator for up to 24 hours. Tetrofosmin which has been labeled with technetium-99m can with stand up 7 hours. It is concluded that expiry date of liquid tetrofosmin kit related with storage temperature, the lower the temperature the longer the expiry date of the kits.

  17. Clinical usefulness of delayed exercise images on 99mTc-tetrofosmin myocardial SPECT in the diagnosis of vasospastic angina pectoris

    International Nuclear Information System (INIS)

    Ito, Kazuki; Zen, Kan; Hikosaka, Takatou; Adachi, Yoshihiko; Yoneyama, Satoshi; Katoh, Shuuji; Sugihara, Hiroki; Nakamura, Tomoki; Azuma, Akihiro

    2000-01-01

    This study was designed to evaluate the clinical usefulness of delayed exercise images in 99m Tc-tetrofosmin (TF) myocardial SPECT in the diagnosis of vasospastic angina pectoris. We studied 30 patients with vasospastic angina, 10 of 30 patients (group A) had both effort and rest angina, 20 of 30 patients (group B) had rest angina. A 370 MBq of TF was intravenously injected at peak exercise, and initial (EX-I) and delayed exercise (EX-D) images were obtained at 30 min and 180 min after the injection. An additional 740 MBq of TF was intravenously reinjected after EX-D image acquisition, and rest images were obtained 30 min after the reinjection. The left ventricular wall was divided into 9 segments. Regional myocardial uptakes of TF were scored by 4-point defect score (0=normal, 1=mildly reduced, 2=moderately reduced, and 3=severely reduced). Total defect score (TDS) was calculated from the sum of defect scores in 9 segments. Reverse redistribution (RR) was defined as increase of more than 2 in TDS on EX-D images. In group A, 4 of 10 cases (40%) showed decreased uptake on EX-I images, 6 of 10 cases (60%) revealed RR on EX-D images, and none of the patients showed decreased uptake on rest images. In group B, no one showed decreased uptake on EX-I and rest images, 11 of 20 cases (55%) revealed RR on EX-D images. The mean±SD of TDS were 2.9±3.4, 5.1±4.5, 0.5±0.5 on EX-I, EX-D, rest images in group A, and serially 0.4±0.5, 3.3±3.6, 0.4±0.5 in group B. Regional wall motion abnormality was reduced in regions with RR. RR on EX-D images may reflect ischemic damaged but viable myocardium in vasospastic angina. The clinical usefulness of exercise-rest TF imaging in detection of organic coronary artery disease has been well established. Therefore, exercise-rest TF imaging with additional delayed exercise image could evaluate not only organic coronary artery disease but also coronary artery vasospasm. (author)

  18. MR imaging in tumor invasion of the chest wall

    International Nuclear Information System (INIS)

    Bittner, R.C.; Lang, P.; Schorner, W.; Sander, B.; Weiss, T.; Loddenkemper, R.; Kaiser, D.; Felix, R.

    1989-01-01

    The authors have used MR imaging to study 22 patients who had intrathoracic, pleura-related malignancies and whose CT findings had suggested chest wall invasion. ECG-gated T1- and T2-weighted spin-echo sequences were used in all patients. Additionally, in 10 patients an ungated, multisection, gradient-echo sequence was used, which was repeated after intravenous administration of Gd-DTPA in five patients. Surgery confirmed chest wall invasion in 19 patients. CT showed tumor invasion only in 14 of these 19 patients. MR imaging showed high-signal-intensity lesion within chest wall and pleura in T2-weighted and Gd-DTPA-enhanced T1-weighted images as the typical pattern of chest wall invasion in all 19 patients. Two of the three patients with pleural inflammation and without chest wall invasion had high-signal-intensity pleural lesions, but none of these lesions were within the chest wall

  19. Diagnostic image quality of video-digitized chest images

    International Nuclear Information System (INIS)

    Winter, L.H.; Butler, R.B.; Becking, W.B.; Warnars, G.A.O.; Haar Romeny, B. ter; Ottes, F.P.; Valk, J.-P.J. de

    1989-01-01

    The diagnostic accuracy obtained with the Philips picture archiving and communications subsystem was investigated by means of an observer performance study using receiver operating characteristic (ROC) analysis. The image qualities of conventional films and video digitized images were compared. The scanner had a 1024 x 1024 x 8 bit memory. The digitized images were displayed on a 60 Hz interlaced display monitor 1024 lines. Posteroanterior (AP) roetgenograms of a chest phantom with superimposed simulated interstitial pattern disease (IPD) were produced; there were 28 normal and 40 abnormal films. Normal films were produced by the chest phantom alone. Abnormal films were taken of the chest phantom with varying degrees of superimposed simulated intersitial disease (PND) for an observer performance study, because the results of a simulated interstitial pattern disease study are less likely to be influenced by perceptual capabilities. The conventional films and the video digitized images were viewed by five experienced observers during four separate sessions. Conventional films were presented on a viewing box, the digital images were displayed on the monitor described above. The presence of simulated intersitial disease was indicated on a 5-point ROC certainty scale by each observer. We analyzed the differences between ROC curves derived from correlated data statistically. The mean time required to evaluate 68 digitized images is approximately four times the mean time needed to read the convential films. The diagnostic quality of the video digitized images was significantly lower (at the 5% level) than that of the conventional films (median area under the curve (AUC) of 0.71 and 0.94, respectively). (author). 25 refs.; 2 figs.; 4 tabs

  20. Comparative study of gated myocardial perfusion imaging using 99Tcm-tetrofosmin and 99Tcm-sestamibi

    International Nuclear Information System (INIS)

    Wang Ruihua; Ruan Qiao; Sun Ke; Han Xingmin; Sun Bingqi; Xie Xinli; Cheng Bing; Chen Yanlin; Liu Baoping

    2013-01-01

    Objective: To compare the results of 99 Tc m -tetrofosmin (TF) and 99 Tc m -MIBI G-MPI in evaluating left ventricular myocardial perfusion and other functional parameters. Methods: TF and MIBI were both labeled by 99 Tc m and the radiochemical purities were tested. During December 2011 to May 2012, 112 patients who had examinations of CAG and echocardiograph in one week after G-MPI were divided into 99 Tc m -TF group (47 patients) and 99 Tc m -MIBI group (65 patients) by simple random sampling. Patients who suffered from severe arrhythmia, clinically suspicious of myocarditis or cardiomyopathy were excluded. The research was approved by the ethics committee, and all patients signed informed consents. One-day 99 Tc m -TF G-MPI and two-day 99 Tc m -MIBI G-MPI were performed. The left ventricular functional parameters were acquired automatically by Cedars quantitative gated SPECT (QGS) software, including LVEF, EDV, ESV, peak filling rate (PFR), peak ejection rate (PER) and phase standard difference (SD). The data were analyzed using χ 2 test, two-sample t test, paired t test and linear correlation analysis by SPSS 17.0. Results: The radiochemical purities of 99 Tc m -TF and 99 Tc m -MIBI were (97.5±0.4) % and (99.1±0.2) % respectively. The coincidence rates of 99 Tc m -TF and 99 Tc m -MIBI G-MPI with CAG were 88.9% (40/45) and 90.5% (57/63), respectively. There was no significant difference between G-MPI results of the two agents (χ 2 =0.389, P>0.05). There was also no significant difference between left ventricular functional parameters of the two agents (LVEF:(62.60±13.56)% vs (60.52±7.08)%, t=0.940; EDV: (103.3±17.29) ml vs (98.52±19.37) ml, t=1.348; ESV: (41.73±12.69) ml vs (46.05±10.81) ml, t=0.851; PER: (2.73±0.67)EDV/s vs (2.61±1.04) EDV/s, t=0.725; PFR: (2.13±0.80) EDV/s vs (2.07±1.09) EDV/s, t=0.339; phase SD: (5.58±4.16)° vs (5.97±4.64)°, t=0.450; all P>0.05). There was no significant difference between left ventricular functional

  1. Influence of MR imaging in radiation therapy of chest lymphoma

    International Nuclear Information System (INIS)

    Carlsen, S.E.; Hoppe, R.; Bergin, C.J.

    1991-01-01

    This paper evaluates the influence of MR detection of additional sites of chest lymphoma on radiation therapy. Chest MR images and CT scans of 56 patients with new or recurrent mediastinal lymphoma obtained within 1 month of each other were retrospectively reviewed. MR images included T1- and T2-weighted SE and STIR sequences. Images were assessed for pleural and extrapleural disease. Radiation portals of patients with pleural or chest wall disease were reevaluated and compared with portals originally designed with CT. MR imaging demonstrated chest wall disease in 15 patients (21 sites). Ten patients also had pleural disease (13 sites). CT identified chest wall disease in four of these patients (five sites) and pleural disease in three patients (five sites). Seven of the 15 patients with chest wall disease were treated with radiation therapy alone. Two of the seven patients had significant modification of radiation portals based on MR findings. Retrospectively, therapy would have been altered in an additional two patients in whom pleural disease was identified at MR. The increased sensitivity of MR in detecting chest wall or pleural disease has important implications for treatment planning in chest wall lymphoma

  2. Aspergillosis - chest x-ray (image)

    Science.gov (United States)

    ... usually occurs in immunocompromised individuals. Here, a chest x-ray shows that the fungus has invaded the lung ... are usually seen as black areas on an x-ray. The cloudiness on the left side of this ...

  3. Tuberculosis, advanced - chest x-rays (image)

    Science.gov (United States)

    Tuberculosis is an infectious disease that causes inflammation, the formation of tubercules and other growths within tissue, ... death. These chest x-rays show advanced pulmonary tuberculosis. There are multiple light areas (opacities) of varying ...

  4. Adenocarcinoma - chest x-ray (image)

    Science.gov (United States)

    This chest x-ray shows adenocarcinoma of the lung. There is a rounded light spot in the right upper lung (left side ... density. Diseases that may cause this type of x-ray result would be tuberculous or fungal granuloma, and ...

  5. Digital training platform for interpreting radiographic images of the chest.

    Science.gov (United States)

    McLaughlin, L; Woznitza, N; Cairns, A; McFadden, S L; Bond, R; Hughes, C M; Elsayed, A; Finlay, D; McConnell, J

    2018-05-01

    Time delays and errors exist which lead to delays in patient care and misdiagnosis. Reporting clinicians follow guidance to form their own search strategy. However, little research has tested these training guides. With the use of eye tracking technology and expert input we developed a digital training platform to be used in chest image interpretation learning. Two sections of a digital training platform were planned and developed; A) a search strategy training tool to assist reporters during their interpretation of images, and B) an educational tool to communicate the search strategies of expert viewers to trainees by using eye tracking technology. A digital training platform for use in chest image interpretation was created based on evidence within the literature, expert input and two search strategies previously used in clinical practice. Images and diagrams, aiding translation of the platform content, were incorporated where possible. The platform is structured to allow the chest image interpretation process to be clear, concise and methodical. A search strategy was incorporated within the tool to investigate its use, with the possibility that it could be recommended as an evidence based approach for use by reporting clinicians. Eye tracking, a checklist and voice recordings have been combined to form a multi-dimensional learning tool, which has never been used in chest image interpretation learning before. The training platform for use in chest image interpretation learning has been designed, created and digitised. Future work will establish the efficacy of the developed approaches. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  6. 1024 matrix image reconstruction: usefulness in high resolution chest CT

    International Nuclear Information System (INIS)

    Jeong, Sun Young; Chung, Myung Jin; Chong, Se Min; Sung, Yon Mi; Lee, Kyung Soo

    2006-01-01

    We tried to evaluate whether high resolution chest CT with a 1,024 matrix has a significant advantage in image quality compared to a 512 matrix. Each set of 512 and 1024 matrix high resolution chest CT scans with both 0.625 mm and 1.25 mm slice thickness were obtained from 26 patients. Seventy locations that contained twenty-four low density lesions without sharp boundary such as emphysema, and forty-six sharp linear densities such as linear fibrosis were selected; these were randomly displayed on a five mega pixel LCD monitor. All the images were masked for information concerning the matrix size and slice thickness. Two chest radiologists scored the image quality of each ar rowed lesion as follows: (1) undistinguishable, (2) poorly distinguishable, (3) fairly distinguishable, (4) well visible and (5) excellently visible. The scores were compared from the aspects of matrix size, slice thickness and the different observers by using ANOVA tests. The average and standard deviation of image quality were 3.09 (± .92) for the 0.625 mm x 512 matrix, 3.16 (± .84) for the 0.625 mm x 1024 matrix, 2.49 (± 1.02) for the 1.25 mm x 512 matrix, and 2.35 (± 1.02) for the 1.25 mm x 1024 matrix, respectively. The image quality on both matrices of the high resolution chest CT scans with a 0.625 mm slice thickness was significantly better than that on the 1.25 mm slice thickness (ρ < 0.001). However, the image quality on the 1024 matrix high resolution chest CT scans was not significantly different from that on the 512 matrix high resolution chest CT scans (ρ = 0.678). The interobserver variation between the two observers was not significant (ρ = 0.691). We think that 1024 matrix image reconstruction for high resolution chest CT may not be clinical useful

  7. A comparison between 99Tcm-tetrofosmin and 99Tcm-MIBI myocardial perfusion imaging in detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Fu Wei; Tang Yi; Liu Xuemei; Fan Yan; Liu Tao

    2012-01-01

    Objective: To compare 99 Tc m -tetrofosmin (TF) and 99 Tc m -MIBI adenosine stress/resting MPI in detection of silent myocardial ischemia (SMI). Methods: According to the WHO diagnostic criteria for coronary heart disease (CHD), 306 SMI patients were classified to three groups as type Ⅰ (n=122), type Ⅱ (n=112) and type Ⅲ (n=72). The subjects of each type were randomly divided into 2 subgroups; one subgroup underwent adenosine stress/rest MPI with 99 Tc m -MIBI and another subgroup with 99 Tc m -TF. The clinical diagnosis of CHD was proven with electrocardiogram (46 cases), dynamic electrocardiogram (219 cases) or CAG (41 cases). Comparison factors between the two tracers included image quality and diagnostic efficacy. The image quality was graded into three classes:excellent, good and moderate. χ 2 test and analysis of variance were used to analyze data. Results: The sensitivities of detecting myocardial ischemia with 99 Tc m -MIBI MPI and 99 Tc m -TF MPI in group type Ⅰ were 57.38% (35/61) vs 60.66% (37/61) (χ 2 =0.136, P>0.05); in group type Ⅱ 69.64% (39/56) vs 64.29% (36/56) (χ 2 =0.363, P>0.05) and in group type Ⅲ 83.33% (30/36) vs 88.89% (32/36) (χ 2 =0.465, P>0.05), respectively. There was no significant difference between the sensitivities of the two imaging modalities in all three types of SMI patients.In image quality grading, 99 Tc m -MIBI and 99 Tc m -TF demonstrated excellent images with 41.18% (63/153) vs 48.37% (74/153) (χ 2 =1.599, P=0.206), good with 45.10% (69/153) vs 34.64% (53/153) (χ 2 =3.489, P=0.062) and moderate with 13.72% (21/153) vs 16.99%(26/153) (χ 2 =0.628, P=0.428). There was no unqualified image with either modality. 99 Tc m -TF displayed quicker radioactivity clearance in liver and lungs. Thereby there was less interference or pitfalls present in the ventricle base or interior wall that may result from higher liver radioactivity retention. The waiting time between the tracer injection and imaging was at least 1 h

  8. Dose and perceived image quality in chest radiography

    International Nuclear Information System (INIS)

    Veldkamp, Wouter J.H.; Kroft, Lucia J.M.; Geleijns, Jacob

    2009-01-01

    Chest radiography is the most commonly performed diagnostic X-ray examination. The radiation dose to the patient for this examination is relatively low but because of its frequent use, the contribution to the collective dose is considerable. Consequently, optimization of dose and image quality offers a challenging area of research. In this article studies on dose reduction, different detector technologies, optimization of image acquisition and new technical developments in image acquisition and post processing will be reviewed. Studies indicate that dose reduction in PA chest images to at least 50% of commonly applied dose levels does not affect diagnosis in the lung fields; however, dose reduction in the mediastinum, upper abdomen and retrocardiac areas appears to directly deteriorate diagnosis. In addition to patient dose, also the design of the various digital detectors seems to have an effect on image quality. With respect to image acquisition, studies showed that using a lower tube voltage improves visibility of anatomical structures and lesions in digital chest radiographs but also increases the disturbing appearance of ribs. New techniques that are currently being evaluated are dual energy, tomosynthesis, temporal subtraction and rib suppression. These technologies may improve diagnostic chest X-ray further. They may for example reduce the negative influence of over projection of ribs, referred to as anatomic noise. In chest X-ray this type of noise may be the dominating factor in the detection of nodules. In conclusion, optimization and new developments will enlarge the value of chest X-ray as a mainstay in the diagnosis of chest diseases.

  9. Revisit image control for pediatric chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kohda, Ehiichi; Nagamoto, Masashi; Gomi, Tatsuya; Terada, Hitoshi; Kawawa, Yohko [Toho Univ., School of Medicine, Tokyo (Japan); Tsutsumi, Yoshiyuki; Masaki, Hidekazu [National Center for Child Health and Development, Tokyo (Japan); Shiraga, Nobuyuki [Kyousai Tachikawa Hospital, Tachikawa, Tokyo (Japan)

    2007-02-15

    The aim of this study was to analyze the fraction defectiveness and efficacy of the patient immobilization device (PID) for pediatric chest radiography. We examined 840 plain chest radiographs in six hospitals, including four children's hospitals and two general hospitals. The mean age of the patients was 1.9 years (range 0-5 years). Two boardqualified pediatric radiologists rated (into three grades, by consensus) the degree of inspiration, rotation, lordosis, scoliosis, and cutoff or coning as well as the quality of the chest radiographs. The incidence of ''poor'' and ''very poor'' quality examinations was 2/140 and 3/140 in each of two children's hospitals using PID. The corresponding figures were 9/139 and 17/140 in the two children's hospitals that did not use PID. The general hospital using PID had 14/140 ''poor'' and ''very poor'' examinations. The general hospital that did not use PID had 28/140 ''poor'' and ''very poor'' examinations. Thus, statistically better quality chest radiography was obtained with the use of PID (P<0.001). Likewise, rotation, lordosis, and scoliosis were less frequently diagnosed as present when PID was used (P<0.001, 0.001, 0.05). Cutoff or coning had no relation to the use of PID (P=0.13). No significant difference was found between the degree of inspiration and the use of PID (P=0.56). Fraction defectiveness in the general hospital that did not use PID was as much as 14 times higher than that of the children's hospitals that used PID. The patient immobilization device is recommended for hospitals with technologists not specifically trained for pediatric examination. (author)

  10. Revisit image control for pediatric chest radiography

    International Nuclear Information System (INIS)

    Kohda, Ehiichi; Nagamoto, Masashi; Gomi, Tatsuya; Terada, Hitoshi; Kawawa, Yohko; Tsutsumi, Yoshiyuki; Masaki, Hidekazu; Shiraga, Nobuyuki

    2007-01-01

    The aim of this study was to analyze the fraction defectiveness and efficacy of the patient immobilization device (PID) for pediatric chest radiography. We examined 840 plain chest radiographs in six hospitals, including four children's hospitals and two general hospitals. The mean age of the patients was 1.9 years (range 0-5 years). Two boardqualified pediatric radiologists rated (into three grades, by consensus) the degree of inspiration, rotation, lordosis, scoliosis, and cutoff or coning as well as the quality of the chest radiographs. The incidence of ''poor'' and ''very poor'' quality examinations was 2/140 and 3/140 in each of two children's hospitals using PID. The corresponding figures were 9/139 and 17/140 in the two children's hospitals that did not use PID. The general hospital using PID had 14/140 ''poor'' and ''very poor'' examinations. The general hospital that did not use PID had 28/140 ''poor'' and ''very poor'' examinations. Thus, statistically better quality chest radiography was obtained with the use of PID (P<0.001). Likewise, rotation, lordosis, and scoliosis were less frequently diagnosed as present when PID was used (P<0.001, 0.001, 0.05). Cutoff or coning had no relation to the use of PID (P=0.13). No significant difference was found between the degree of inspiration and the use of PID (P=0.56). Fraction defectiveness in the general hospital that did not use PID was as much as 14 times higher than that of the children's hospitals that used PID. The patient immobilization device is recommended for hospitals with technologists not specifically trained for pediatric examination. (author)

  11. Diagnostic value of 123I-betamethyl-p-iodophenyl-pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) in patients with chest pain. Comparison with rest-stress 99mTc-tetrofosmin SPECT and coronary angiography

    International Nuclear Information System (INIS)

    Kawai, Yuko; Nozaki, Yoichi; Ohkusa, Takanori; Sakurai, Masayuki; Morita, Koichi; Tamaki, Nagara

    2004-01-01

    Basic and clinical studies have indicated that 15-(p-[ 123 I] iodophenyl)-3-(R, S) methylpentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) can identify ischemic myocardium without evidence of myocardial infarction by the regional decline of tracer uptake. The present study compared BMIPP SPECT with rest-stress myocardial perfusion imaging (MPI) findings and coronary angiography (CAG) in 150 patients with acute chest pain. Patients with acute chest pain who underwent all of the following tests were selected: MPI at rest-stress, BMIPP SPECT at rest and CAG. Organic coronary artery stenosis (≥75%) was observed in 46 patients, 27 patients had total or subtotal coronary occlusion by spasm in the spasm provocation test on CAG and the remaining 77 patients had no significant coronary artery stenosis or spasm. The sensitivity of BMIPP at rest to detect organic stenosis was significantly higher (54%) than that of rest-MPI (33%, p<0.005), but lower than that of stress-MPI (76%, p=0.05). The sensitivity of BMIPP at rest to detect spasm was significantly higher (63%) than that of both rest-MPI (15%; p<0.001) and stress-MPI (19%; p<0.001). Overall, the sensitivity of BMIPP at rest to detect both organic stenosis and spasm was significantly higher (58%) than that of rest-MPI (26%; p<0.001), despite having no significance with that of stress-MPI (55%). The specificity was not significantly different among the three imaging techniques. Resting BMIPP SPECT is an alternative method to stress MPI for identifying patients with not only organic stenosis but also spasm without the need for a stress examination. (author)

  12. Tc-99m-tetrofosmin scintimammography: A prospective study in primary breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lind, P. [LKH Klagenfurt (Austria). Dept. of Nuclear Medicine and Special Endocrinology; Gallowitsch, H.J. [LKH Klagenfurt (Austria). Dept. of Nuclear Medicine and Special Endocrinology; Kogler, D. [LKH Klagenfurt (Austria). Dept. of Radiology; Kresnik, E. [LKH Klagenfurt (Austria). Dept. of Nuclear Medicine and Special Endocrinology; Mikosch, P. [LKH Klagenfurt (Austria). Dept. of Nuclear Medicine and Special Endocrinology; Gomez, I. [LKH Klagenfurt (Austria). Dept. of Nuclear Medicine and Special Endocrinology

    1996-12-01

    The purpose of our study was to evaluate prospectively the sensitivity, specificity, PPV and NPV of scintimammography with a new catonic complex Tc-99m-tetrofosmin. Methods: Fourtyeight patients in whom mammography and/or high resolution ultrasonography (10 MHz) revealed suspicious breast lesions were studied with Tc-99m-tetrofosmin scintimammography. In thirty four of them biopsy and/or surgery was performed for histological evaluation. After intravenous injection of 555 MBq Tc-99m-tetrofosmin dynamic images over three minutes planar images in anterior and lateral projections and SPECT imaging including 3-D-reconstruction (20 min. p.i.) were performed. Scintimammography was evaluated as negative, equivocal (+), probably (++) or definitely (+++) positive. Results: Scintimammography with Tc-99m-tetrofosmin was negative in 18 patients (17 t.n.; 1 f.n.) and positive in 16 patients (10 t.p., 6 f.p.). The false negative scintimammography was observed in a patient with infiltrating ductal carcinoma pT1, the false positive result in a patient with fibrocystic disease; all of the five fibroadenomas were also `false` positive. Sensitivity of Tc-99m-tetrofosmin scintimammography in this prospective study was 91%, specificity 74%, PPV 63% and NPV 94%. Scintimammographic results in patients with suspicious breast lesion show, that Tc-99m-tetrofosmin accumulates in breast cancer as well as in fibroadenoma. However the high NPV of 94% excludes breast cancer in suspicious mammographic lesions in a very high degree and therefore reduces the need of biopsy and/or surgery in most of these patients. Conclusion: Our first results show that scintimammography with Tc-99m-tetrofosmin might play a role as further diagnostic step before surgery for women in whom mammography and/or ultrasonography show suspicious lesions. [Deutsch] Ziel unserer prospektiven Studie war es, die Sensitivitaet, Spezifitaet sowie den positiven (PVW) und negativen Voraussagewert (NVW) der Mammoszintigraphie

  13. Automated image quality assessment for chest CT scans.

    Science.gov (United States)

    Reeves, Anthony P; Xie, Yiting; Liu, Shuang

    2018-02-01

    Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.

  14. TC-99M tetrofosmin scintimammography in diagnosis of breast cancer patients

    International Nuclear Information System (INIS)

    Jaukovic, L.; Spaic, R.; Ajdinovic, B.

    2004-01-01

    99m Tc Tetrofosmin is a cationic complex developed for myocardial perfusion imaging, also used in diagnosis of patients with various malignancies. AIM of this study was to compare the diagnostic accuracy of 99m Tc-Tetrofosmin scintimammography (SMM) and X-ray mammography (MM) in detection of primary breast cancer. Method: Twenty eight female patients (mean age 52.4) with 30 breast lesions suspicious for malignancy were comprised in the study. In all patients were performed clinical investigation, MM, SMM and biopsy/surgery for final histopathologic diagnosis. Patients were injected by 555 MBq 99m Tc-Tetrofosmin intravenously, cubitaly, in the arm contralateral to the side of suspicious lesion. Seven minutes static scans or' at least 2.0 million counts were obtained. Planar images were acquired in left and right prone lateral view as well as in the supine position for an anterior view of chest and axilary region. SMM scans were interpreted visuely regarding the tracer' uptake in tumor and background tissue. SMM scans and mammograms of 30 lesions were compared to the definitive histopathologic (HP) using decision matrix and the results expressed as: sensitivity, specificity, accuracy, positive (PPV) and negative predictive value (NPV). HP analysis revealed 20 malignant and 10 benign lesions. Out of 23 patients with positive SMM scans 19 were related to breast cancer ( 15 invasive ductal, 1 invasive lobular, 1 papilllar, 1 colloid cancer and 1 cystosarcoma phyllodes-malignant type). Comparing the sensitivity in our group of patients, MM 'missed' four cancer lesions and SMM only one (1.0 cm invasive ductal carcinoma). Three of four false positive SMM results were obtained in patients with fibroadenomas bigger than 2.0 cm. Conclusion: SMM could play an important role as a part of the diagnostic protocol in patients with breast lesion suspicious for malignancy. This protocol is aimed to reduce the number of biopsies performed on benign lesions, and in the other hand to

  15. Evaluation of thyroid nodules with technetium-99m tetrofosmin dual-phase scintigraphy

    International Nuclear Information System (INIS)

    Kresnik, E.; Gallowitsch, H.J.; Mikosch, P.; Molnar, M.; Pipam, W.; Gomez, I.; Lind, P.

    1997-01-01

    Technetium-99m tetrofosmin, a lipophilic cationic complex molecule, was introduced for myocardial imaging. In some biodistribution studies it has also been reported to accumulate in the thyroid gland. Our objectives were to determine which thyroid nodules retain tetrofosmin and whether preoperative evaluation of malignancy is possible. Tetrofosmin scintigraphy was performed in 57 patients with a cold thyroid nodule on previously performed pertechnetate scintigraphy. All patients had undergone ultrasonography and sonographically guided fine-needle aspiration biopsy. The tetrofosmin scintigrams were obtained 5 min (early image) and 1 h (late image) after intravenous injection of 370 MBq. Only nodules that showed clear tracer retention after 1 h in comparison with retention at 5 min were classified as TETRO positive. Nodules without late retention were classified as TETRO negative. All patients underwent surgery and the histological results were compared with the results of tetrofosmin scintigraphy. Ten out of 11 patients with thyroid carcinoma (two pT1, three pT2, five pT4) were TETRO negative. One patient with papillary carcinoma (pT2) was TETRO positive. The mean nodular to thyroid tissue (N/T) ratio for the late scan was 1.0±0.20. There were 21 patients with thyroid adenomas (seven follicular, seven microfollicular and seven oxyphilic); 15 of these patients were TETRO positive and six TETRO negative. The mean N/T ratio for the late images was 1.34±0.41. All patients with degenerative goitre (24 cases) and the one patient with Hashimoto's disease were TETRO negative after 1 h and the N/T ratio was 0.92±0.12 on the late scan. Our results indicate that 99m Tc-tetrofosmin scanning is of little value preoperatively in distinguishing thyroid carcinoma from other thyroid nodules. Tetrofosmin tends to demonstrate thyroid adenomas but does not have a routine role in the assessment of thyroid nodules. (orig.). With 2 figs., 4 tabs

  16. Early and delayed Tc-99m-tetrofosmin myocardial SPECT in patients with left bundle branch block

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Kinoshita, Noriyuki; Adachi, Yoshihiko

    1998-01-01

    To determine the utility of the myocardial tracer Tc-99m-tetrofosmin in the examination of patients with left bundle branch block (LBBB) and to investigate Tc-99m-tetrofosmin uptake and retention in the myocardium, early and delayed Tc-99m-tetrofosmin SPECT was performed in 10 patients having LBBB without coronary stenosis. After 740 MBq of Tc-99m-tetrofosmin injection in the resting state, the early and delayed SPECT imaging was done at 30 min and 180 min, respectively. Decreased Tc-99m-tetrofosmin uptake in the septal segments was observed in 4 patients (40%) at 30 min and in 9 (90%) at 180 min. Reverse redistribution was seen in 9 of 10 patients. In patients with LBBB, the septal-to-lateral uptake ratio was lower in the delayed images than in the early images (0.80±0.09 vs. 0.89±0.09, p<0.001). In patients with LBBB, the washout rate of Tc-99m-tetrofosmin was higher in the septal segments than in the lateral segments (28.3±4.3% vs. 22.8±3.3%, p<0.001). The SPECT data indicate that in LBBB without coronary stenosis, the uptake of Tc-99m-tetrofosmin is decreased in the septal wall, and that reverse redistribution occurs frequently. Our results contribute to the elucidation of both the cellular biokinetics of Tc-99m-tetrofosmin in the myocardium and the hemodynamics of the septum in LBBB, and indicate the possible clinical utility of Tc-99m-tetrofosmin. (author)

  17. Selective chest imaging for blunt trauma patients: The national emergency X-ray utilization studies (NEXUS-chest algorithm).

    Science.gov (United States)

    Rodriguez, Robert M; Hendey, Gregory W; Mower, William R

    2017-01-01

    Chest imaging plays a prominent role in blunt trauma patient evaluation, but indiscriminate imaging is expensive, may delay care, and unnecessarily exposes patients to potentially harmful ionizing radiation. To improve diagnostic chest imaging utilization, we conducted 3 prospective multicenter studies over 12years to derive and validate decision instruments (DIs) to guide the use of chest x-ray (CXR) and chest computed tomography (CT). The first DI, NEXUS Chest x-ray, consists of seven criteria (Age >60years; rapid deceleration mechanism; chest pain; intoxication; altered mental status; distracting painful injury; and chest wall tenderness) and exhibits a sensitivity of 99.0% (95% confidence interval [CI] 98.2-99.4%) and a specificity of 13.3% (95% CI, 12.6%-14.0%) for detecting clinically significant injuries. We developed two NEXUS Chest CT DIs, which are both highly reliable in detecting clinically major injuries (sensitivity of 99.2%; 95% CI 95.4-100%). Designed primarily to focus on detecting major injuries, the NEXUS Chest CT-Major DI consists of six criteria (abnormal CXR; distracting injury; chest wall tenderness; sternal tenderness; thoracic spine tenderness; and scapular tenderness) and exhibits higher specificity (37.9%; 95% CI 35.8-40.1%). Designed to reliability detect both major and minor injuries (sensitivity 95.4%; 95% CI 93.6-96.9%) with resulting lower specificity (25.5%; 95% CI 23.5-27.5%), the NEXUS CT-All rule consists of seven elements (the six NEXUS CT-Major criteria plus rapid deceleration mechanism). The purpose of this review is to synthesize the three DIs into a novel, cohesive summary algorithm with practical implementation recommendations to guide selective chest imaging in adult blunt trauma patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Regional variance of visually lossless threshold in compressed chest CT images: Lung versus mediastinum and chest wall

    International Nuclear Information System (INIS)

    Kim, Tae Jung; Lee, Kyoung Ho; Kim, Bohyoung; Kim, Kil Joong; Chun, Eun Ju; Bajpai, Vasundhara; Kim, Young Hoon; Hahn, Seokyung; Lee, Kyung Won

    2009-01-01

    Objective: To estimate the visually lossless threshold (VLT) for the Joint Photographic Experts Group (JPEG) 2000 compression of chest CT images and to demonstrate the variance of the VLT between the lung and mediastinum/chest wall. Subjects and methods: Eighty images were compressed reversibly (as negative control) and irreversibly to 5:1, 10:1, 15:1 and 20:1. Five radiologists determined if the compressed images were distinguishable from their originals in the lung and mediastinum/chest wall. Exact tests for paired proportions were used to compare the readers' responses between the reversible and irreversible compressions and between the lung and mediastinum/chest wall. Results: At reversible, 5:1, 10:1, 15:1, and 20:1 compressions, 0%, 0%, 3-49% (p < .004, for three readers), 69-99% (p < .001, for all readers), and 100% of the 80 image pairs were distinguishable in the lung, respectively; and 0%, 0%, 74-100% (p < .001, for all readers), 100%, and 100% were distinguishable in the mediastinum/chest wall, respectively. The image pairs were less frequently distinguishable in the lung than in the mediastinum/chest wall at 10:1 (p < .001, for all readers) and 15:1 (p < .001, for two readers). In 321 image comparisons, the image pairs were indistinguishable in the lung but distinguishable in the mediastinum/chest wall, whereas there was no instance of the opposite. Conclusion: For JPEG2000 compression of chest CT images, the VLT is between 5:1 and 10:1. The lung is more tolerant to the compression than the mediastinum/chest wall.

  19. Regional variance of visually lossless threshold in compressed chest CT images: Lung versus mediastinum and chest wall

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Jung [Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center (Korea, Republic of); Lee, Kyoung Ho [Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center (Korea, Republic of)], E-mail: kholee@snubhrad.snu.ac.kr; Kim, Bohyoung; Kim, Kil Joong; Chun, Eun Ju; Bajpai, Vasundhara; Kim, Young Hoon [Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center (Korea, Republic of); Hahn, Seokyung [Medical Research Collaborating Center, Seoul National University Hospital, 28 Yongon-dong, Chongno-gu, Seoul 110-744 (Korea, Republic of); Seoul National University College of Medicine (Korea, Republic of); Lee, Kyung Won [Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center (Korea, Republic of)

    2009-03-15

    Objective: To estimate the visually lossless threshold (VLT) for the Joint Photographic Experts Group (JPEG) 2000 compression of chest CT images and to demonstrate the variance of the VLT between the lung and mediastinum/chest wall. Subjects and methods: Eighty images were compressed reversibly (as negative control) and irreversibly to 5:1, 10:1, 15:1 and 20:1. Five radiologists determined if the compressed images were distinguishable from their originals in the lung and mediastinum/chest wall. Exact tests for paired proportions were used to compare the readers' responses between the reversible and irreversible compressions and between the lung and mediastinum/chest wall. Results: At reversible, 5:1, 10:1, 15:1, and 20:1 compressions, 0%, 0%, 3-49% (p < .004, for three readers), 69-99% (p < .001, for all readers), and 100% of the 80 image pairs were distinguishable in the lung, respectively; and 0%, 0%, 74-100% (p < .001, for all readers), 100%, and 100% were distinguishable in the mediastinum/chest wall, respectively. The image pairs were less frequently distinguishable in the lung than in the mediastinum/chest wall at 10:1 (p < .001, for all readers) and 15:1 (p < .001, for two readers). In 321 image comparisons, the image pairs were indistinguishable in the lung but distinguishable in the mediastinum/chest wall, whereas there was no instance of the opposite. Conclusion: For JPEG2000 compression of chest CT images, the VLT is between 5:1 and 10:1. The lung is more tolerant to the compression than the mediastinum/chest wall.

  20. Radiological imaging of the neonatal chest. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Donoghue, Veronica (ed.) [Children' s University Hospital, Dublin (Ireland). Dept. of Radiology; National Maternity Hospital, Dublin (Ireland)

    2008-07-01

    This second, revised edition of Radiological Imaging of the Neonatal Chest provides a comprehensive and up-to-date discussion of the subject. It is written primarily from the point of view of the paediatric radiologist but will be of particular interest to all antenatal ultrasonographers, neonatologists, paediatric cardiologists, paediatricians and paediatric surgeons. It includes an update on clinical management and appraises the advantages of the various techniques available to image the newborn chest. There is particular emphasis on the impact of recent therapeutic advances on imaging findings. Extensive consideration is given to both antenatal and postnatal imaging of congenital chest malformations, as well as to controversies regarding the postnatal management of asymptomatic infants with these anomalies. There are dedicated chapters on upper airway problems, infection and congenital heart disease, with special emphasis on the current role of magnetic resonance imaging, computed tomography and interventional therapy. There is also a chapter devoted to computed radiography and digital radiography. This book contains important information for all those involved in caring for the neonate. (orig.)

  1. [Imaging of pleural diseases: evaluation of imaging methods based on chest radiography].

    Science.gov (United States)

    Poyraz, Necdet; Kalkan, Havva; Ödev, Kemal; Ceran, Sami

    2017-03-01

    The most commonly employed radiologic method in diagnosis of pleural diseases is conventional chest radiograph. The commonest chest- X-Ray findings are the presence of pleural effusion and thickening. Small pleural effusions are not readily identified on posteroanterior chest radiograph. However, lateral decubitus chest radiograph and chest ultrasonography may show small pleural effusions. These are more efficient methods than posteroanterior chest radiograph in the erect position for demonstrating small amounts of free pleural effusions. Chest ultrasonograph may be able to help in distinguishing the pleural pathologies from parenchymal lesions. On chest radiograph pleural effusions or pleural thickening may obscure the visibility of the underlying disease or parenchymal abnormality. Thus, computed tomography (CT) may provide additional information of determining the extent and severity of pleural disease and may help to differentiate malign pleural lesions from the benign ones. Moreover, CT may provide the differentiation of parenchmal abnormalities from pleural pathologies. CT (coronal and sagittal reformatted images) that also show invasion of chest wall, mediastinum and diaphragm, as well as enlarged hilar or mediastinal lymph nodes. Standart non-invasive imaging techniques may be supplemented with magnetic resonans imaging (MRI).

  2. Angular relational signature-based chest radiograph image view classification.

    Science.gov (United States)

    Santosh, K C; Wendling, Laurent

    2018-01-22

    In a computer-aided diagnosis (CAD) system, especially for chest radiograph or chest X-ray (CXR) screening, CXR image view information is required. Automatically separating CXR image view, frontal and lateral can ease subsequent CXR screening process, since the techniques may not equally work for both views. We present a novel technique to classify frontal and lateral CXR images, where we introduce angular relational signature through force histogram to extract features and apply three different state-of-the-art classifiers: multi-layer perceptron, random forest, and support vector machine to make a decision. We validated our fully automatic technique on a set of 8100 images hosted by the U.S. National Library of Medicine (NLM), National Institutes of Health (NIH), and achieved an accuracy close to 100%. Our method outperforms the state-of-the-art methods in terms of processing time (less than or close to 2 s for the whole test data) while the accuracies can be compared, and therefore, it justifies its practicality. Graphical Abstract Interpreting chest X-ray (CXR) through the angular relational signature.

  3. Cu filtration for dose reduction in neonatal chest imaging

    International Nuclear Information System (INIS)

    Smans, K.; Struelens, L.; Smet, M.; Bosmans, H.; Vanhavere, F.

    2010-01-01

    As neonatal chest images are frequently acquired to investigate the life-threatening lung diseases in prematurely born children, their optimisation in terms of X-ray exposure is required. The aim of this study was to investigate whether such dose-optimisation studies could be performed using a Monte Carlo computer model. More specifically, a Monte Carlo computer model was used to investigate the influence of Cu filtration on image quality and dose in neonatal chest imaging. Monte Carlo simulations were performed with the MCNPX code and used with voxel models representing prematurely born babies (590 and 1910 g). Physical image quality was derived from simulated images in terms of the signal difference-to-noise ratio and signal-to-noise ratio (SNR). To verify the simulation results, measurements were performed using the Gammex 610 Neonatal Chest Phantom, which represents a 1-2 kg neonate. A figure of merit was used to assist in evaluating the optimum balance between the image quality and the patient dose. The results show that the Monte Carlo computer model to investigate dose and image quality works well and can be used in dose-optimisation studies for real clinical practices. Furthermore, working at a specific constant incident air kerma (K a,I ), additional filtration proved to increase SNR with 30%, whereas working at a specific constant detector dose, extra Cu filtration reduces the lung dose with 25%. Optimum balance between patient dose and image quality is found to be 60 kVp (using extra filtration). (authors)

  4. Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging

    International Nuclear Information System (INIS)

    Yu Jianming; Lei Ziqiao; Kong Xiangchuang

    2006-01-01

    Objective: To investigate the application value of DR dual energy subtraction technology in rib lesions. Methods: 200 patients were performed with chest DR dual energy subtraction, comparing the rib imaging between DR of thorax and chest imaging using ROC analysis. Results: Among the total of 200 patients, there are 50 cases of rib calcification, 7 cases of rib destruction, 22 cases of rib fracture. The calcification, destruction and fracture were displayed respectively by ribs below diaphragm and rib markings. The analytic parameter of rib imaging of DR dual energy subtraction Az is 0.9367, while that of rib imaging of chest Az is 0.6830. Conclusion: DR dual energy subtraction technology is superior to chest imaging in the displaying of rib lesion and ribs below diaphragm. (authors)

  5. Dual-energy chest imaging with the variable compensation technique

    International Nuclear Information System (INIS)

    Dobbins, J.T.; Powell, A.O.

    1988-01-01

    The authors reported on a new imaging algorithm, termed the variable compensation (VC) technique, that combines the signal-to-noise ratio (S/N) advantages of x-ray beam compensation with the ability to adjust retrospectively the amount of displayed image equalization. The VC technique acquires a compensated image of the patient and also an image of the modulated beam profile incident on the patient. A fraction of the beam profile image is then subtracted from the compensated image. A limitation of traditional dual-energy techniques is the significant S/N degradation in poorly penetrated regions. Their new VC technique permits improvement in image S/N before formation of the dual-energy image pair. Specifically, the authors subtract 100% of the beam image from the compensated image for both the high- and low-energy images and produce a pair of images that appear similar to the normal high- and low-energy pair, except for improved S/N in the mediastinum due to the beam compensator. S/N measurements in tissue-canceled chest phantom images show the improved S/N visualization of calcified squares in the mediastinum with our technique

  6. Imaging of chest disease due to intravenous heroin abuse

    International Nuclear Information System (INIS)

    Lian Xuhui; Chen Zhong; Ye Wenqin

    2002-01-01

    Objective: To study the imaging findings of the chest disease due to intravenous heroin abuse. Methods: Twenty-five cases of clinically confirmed chest disease due to intravenous heroin abuse were retrospectively analyzed. 25 cases had conventional X-ray film, 6 cases had CT scanning, and 6 cases had echocardiography scanning. Results: On X-ray and CT, the following signs were found: lung making manifold (n = 5), small patchy shadow (n = 15), pneumatocele (n = 16), small cavity (n = 16), small node (n = 7), pleural effusion (n = 8 ), pneumothorax (n = 2), hydropneumothorax (n = 6), pulmonary edema (n = 2), megacardia (n = 11), multiple-shaped lesion (n = 20). On echocardiography, tricuspid vegetation (n = 4) and tricuspid insufficiency (n = 4) were found. Conclusion: The X-ray and CT manifestations of chest inflammation due to intravenous heroin abuse are multiple. The multiple small cavities and pneumatoceles sign are of some value in the diagnosis of lung inflammation due to intravenous heroin abuse among young patients

  7. Imaging of occupational and environmental disorders of the chest

    International Nuclear Information System (INIS)

    Gevenois, P.A.; Vuyst, P. de

    2006-01-01

    The spectrum of occupational and environmental diseases has changed markedly in recent years. New industrial processes have led to the production and use of a wide range of chemicals, metals, and alloys, an increasing number of which have been reported to cause interstitial lung disease in exposed workers. Thus, while the workforce in coal mining and asbestos handling has decreased, new groups of workers are at risk of exposure to agents potentially responsible for pneumoconiosis. This well-illustrated book, written by internationally acclaimed experts, provides a comprehensive approach to modern imaging of environmental and occupational diseases of the chest. The first part of the book addresses the basic knowledge required to understand imaging in this context, while the second focuses on the imaging results achieved in a variety of specific disorders. There is particular emphasis on thin-section computed tomography since this technique facilitates the detection of early subclinical abnormalities. (orig.)

  8. Effects of optimization and image processing in digital chest radiography

    International Nuclear Information System (INIS)

    Kheddache, S.; Maansson, L.G.; Angelhed, J.E.; Denbratt, L.; Gottfridsson, B.; Schlossman, D.

    1991-01-01

    A digital system for chest radiography based on a large image intensifier was compared to a conventional film-screen system. The digital system was optimized with regard to spatial and contrast resolution and dose. The images were digitally processed for contrast and edge enhancement. A simulated pneumothorax and two and two simulated nodules were positioned over the lungs and the mediastinum of an anthro-pomorphic phantom. Observer performance was evaluated with Receiver Operating Characteristic (ROC) analysis. Five observers assessed the processed digital images and the conventional full-size radiographs. The time spent viewing the full-size radiographs and the digital images was recorded. For the simulated pneumothorax, the results showed perfect performance for the full-size radiographs and detectability was high also for the processed digital images. No significant differences in the detectability of the simulated nodules was seen between the two imaging systems. The results for the digital images showed a significantly improved detectability for the nodules in the mediastinum as compared to a previous ROC study where no optimization and image processing was available. No significant difference in detectability was seen between the former and the present ROC study for small nodules in the lung. No difference was seen in the time spent assessing the conventional full-size radiographs and the digital images. The study indicates that processed digital images produced by a large image intensifier are equal in image quality to conventional full-size radiographs for low-contrast objects such as nodules. (author). 38 refs.; 4 figs.; 1 tab

  9. Acceptable levels of digital image compression in chest radiology

    International Nuclear Information System (INIS)

    Smith, I.

    2000-01-01

    The introduction of picture archival and communications systems (PACS) and teleradiology has prompted an examination of techniques that optimize the storage capacity and speed of digital storage and distribution networks. The general acceptance of the move to replace conventional screen-film capture with computed radiography (CR) is an indication that clinicians within the radiology community are willing to accept images that have been 'compressed'. The question to be answered, therefore, is what level of compression is acceptable. The purpose of the present study is to provide an assessment of the ability of a group of imaging professionals to determine whether an image has been compressed. To undertake this study a single mobile chest image, selected for the presence of some subtle pathology in the form of a number of septal lines in both costphrenic angles, was compressed to levels of 10:1, 20:1 and 30:1. These images were randomly ordered and shown to the observers for interpretation. Analysis of the responses indicates that in general it was not possible to distinguish the original image from its compressed counterparts. Furthermore, a preference appeared to be shown for images that have undergone low levels of compression. This preference can most likely be attributed to the 'de-noising' effect of the compression algorithm at low levels. Copyright (1999) Blackwell Science Pty. Ltd

  10. Comparison of the uptakes of Tc-99m MIBI and Tc-99m tetrofosmin in A549, an MRP-expressing cancer cell, in vitro and in vivo

    International Nuclear Information System (INIS)

    Yoo, Jeong Ah; Jeong, Shin Young; Seo, Myung Rang; Bae, Jin Ho; Ahn, Byeong Cheol; Lee, Kyu Bo; Lee, Jae Tae; Choi, Sang Woon; Lee, Byung Ho

    2003-01-01

    240 min) were progressively higher by the time up to 240 min with CsA. These results indicate that MIBI and tetrofosmin are suitable tracers for imaging MRP-mediated drug resistance in A549 tumors. MIBI may be a better tracer than tetrofosmin for evaluating MRP reversal effect of modulators

  11. Automatic anatomically selective image enhancement in digital chest radiography

    International Nuclear Information System (INIS)

    Sezan, M.I.; Minerbo, G.N.; Schaetzing, R.

    1989-01-01

    The authors develop a technique for automatic anatomically selective enhancement of digital chest radiographs. Anatomically selective enhancement is motivated by the desire to simultaneously meet the different enhancement requirements of the lung field and the mediastinum. A recent peak detection algorithm and a set of rules are applied to the image histogram to determine automatically a gray-level threshold between the lung field and mediastinum. The gray-level threshold facilitates anatomically selective gray-scale modification and/or unsharp masking. Further, in an attempt to suppress possible white-band or black-band artifacts due to unsharp masking at sharp edges, local-contrast adaptivity is incorporated into anatomically selective unsharp masking by designing an anatomy-sensitive emphasis parameter which varies asymmetrically with positive and negative values of the local image contrast

  12. New Methods for Imaging Evaluation of Chest Wall Deformities

    Directory of Open Access Journals (Sweden)

    Ana Lain

    2017-12-01

    Full Text Available AimThe purpose of this study is to describe the development of an external 3-dimensional (3D scanner as a noninvasive method for imaging chest wall deformities. It allows objective assessment, reconstruction of the area of interest, and evaluation of the severity of the deformity by using external indexes.External 3D scanning systemThe OrtenBodyOne scanner (Orten, Lyon, France uses depth sensors to scan the entire 3D external body surface of a patient. The depth sensors combine structured light with two classic computer vision techniques: depth from focus and depth from stereo. The data acquired are processed and analyzed using the Orten-Clinic software.Materials and methodsTo investigate the performance of the device, a preliminary prospective study (January 2015–March 2016 was carried out in patients attending our hospital chest wall deformities unit. In total, 100 patients (children and young adults with pectus excavatum or pectus carinatum, treated by surgery or non-operative methods were included. In patients undergoing non-operative treatment, external 3D scanning was performed monthly until complete correction was achieved. In surgically treated patients, scanning was done before and after surgical correction. In 42 patients, computed tomography (CT was additionally performed and correlations between the Haller index calculated by CT and the external Haller index using external scanning were investigated using a Student’s test (r = 0.83.ConclusionExternal scanning is an effective, objective, radiation-free means to diagnose and follow-up patients with chest wall deformities. Externally measured indexes can be used to evaluate the severity of these conditions and the treatment outcomes.

  13. Accumulation of Tc-99m-MIBI and Tc-99m-tetrofosmin in tumor cells. Uptake and washout studies

    International Nuclear Information System (INIS)

    Rodrigues, M.; Aghajanian, A.A.; Sinzinger, H.; Kalinowska, W.; Zielinski, C.

    2002-01-01

    Tc-99m-tetrofosmin seem to be promising for the in-vivo imaging and characterization of tumors with high cellular metabolic activity, such as cells rich in mitochondria or enhanced mitochondrial activity

  14. Role of 99mTc-Tetrofosmin scintimammography in diagnosis of breast cancer patients

    International Nuclear Information System (INIS)

    Jaukovic, L.J.; Spaic, R.

    2004-01-01

    Full text: 99mTc Tetrofosmin is a cationic complex developed for myocardial perfusion imaging, also used in diagnosis of patients with various malignancies. The aim of this study was to compare the diagnostic accuracy of 99mTc Tetrofosmin scintimammography (SMM) in detection of primary breast cancer with that of X-ray mammography (MM). Eighty-five patients with suspicious mammographic and/or sonographic findings were referred to our department for SMM. Out of these, 28 female patients (mean age 52.4 years) with 30 breast lesions suspicious for malignancy were included in the study. All the 28 patients underwent, MM, SMM and biopsy/surgery for final histological diagnosis. 555 MBq of 99mTc Tetrofosmin was injected intravenously in the arm contra lateral to the side of suspicious lesion. Seven minutes static scans of at least two million counts were obtained using a large field of view gamma camera coupled with a low energy high-resolution collimator. Planar left lateral and right lateral images were acquired in prone position. An anterior image of chest and axillary region in the supine position with the hands raised above the head was also acquired. SMM scans were interpreted visually vis-a-vis the tracer uptake in tumor and background tissue, as well as the homogeneity of tracer distribution. SMM scans and mammograms of 30 lesions were compared with the definitive histopathological findings using decision matrix and the results were expressed as: sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV). Increased tracer uptake on SMM was noticed in 23 lesions with 19/20 proved to be malignant. The smallest lesion measured only 0.6 cm (infiltrating ductal arcinoma) the biggest one was 5.0 cm in diameter (Cystosarcoma phylode-malignant type). Infiltrating lesions with central necrosis showed diffuse inhomogeneously intense tracer uptake on SMM. In one patient SMM scan presented multifocality of disease while MM showed

  15. Clinical image: Hydatid disease of the chest wall

    Energy Technology Data Exchange (ETDEWEB)

    Graham, R.J.; Berlin, J.W.; Ghahremani, G.G. [Northwestern Univ., Evanston, IL (United States)

    1996-05-01

    Hydatid disease is rarely encountered among the population of the United States, but it affects several million people in sheep-raising regions of the world. Human infestation with Echinococcus granulosus begins following ingestion of its ova, which are excreted into the contaminated water during the usual dog-sheep cycle. Hydatid cysts will then develop most frequently in the liver (75% of cases) and lungs (15%) of the human host. Skeletal involvement has been reported to occur in only 0.5-4.0% of patients in the endemic areas. Because of the rarity and perplexing imaging features of hydatid disease involving the chest wall, we wish herein to present a case evaluated recently at our institution. 5 refs., 1 fig.

  16. Use of resting myocardial scintigraphy during chest pain to exclude diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Barbirato, Gustavo Borges; Azevedo, Jader Cunha de; Felix, Renata Christian Martins; Correa, Patricia Lavatori; Volschan, Andre; Viegas, Monica; Pimenta, Lucia; Dohmann, Hans Fernando Rocha; Mesquita, Evandro Tinoco; Mesquita, Claudio Tinoco

    2009-01-01

    Background: Images of myocardial perfusion taken during an episode of chest pain have been used for patients in the emergency department. Objective: To evaluate the operating characteristics of 99m Tc-Tetrofosmin scintigraphy during an episode of chest pain to exclude the diagnosis of cute myocardial infarction. Methods: One hundred and eight patients admitted with chest pain, or up to four hours after the end of symptoms and non diagnostic electrocardiogram, underwent resting scintigraphy and measurement of troponin I concentrations. Patients with a history of myocardial infarction (MI) were not excluded (24 patients). Troponin I concentrations were determined at admission and 6 hours later. Nuclear physicians performed a blind analysis of the images, and myocardial infarction was confirmed whenever troponin I level increase was three times that of the control. Results: Resting perfusion image was abnormal in all 6 patients with MI. Only 1 patient had a normal image and increased troponin levels. Fifty-five patients had positive images without MI, and 46 patients had normal images and troponin levels. The prevalence of the disease was 6.5%. The sensitivity and specificity of the resting images during an episode of chest pain to diagnose MI was 85.7% and 45.5%, respectively. The negative predictive value was 97.7%. Conclusion: Patients undergoing chest pain protocol with SPECT showed an excellent negative predictive value to exclude diagnosis of myocardial infarction. These results suggest that resting perfusion image is an important tool at the chest pain unit. (author)

  17. 99m-Tc tetrofosmin scintigraphy vs mammography in breast cancer detection

    International Nuclear Information System (INIS)

    Jaukovic, L.J.; Spaic, R.; Markovic, S.; Stankovic, N.; Dimitrijevic, S.; Strbac, M.

    2002-01-01

    99m-Tc tetrofosmin is a widely used radiotracer for breast cancer imaging. Routine mammography ,as a method for screening breast cancer patients, might be insufficient for diagnosis, especially in patients with dense breast. Aim: The aim of this study was to compare the results of mammography (MM) and scintimammography with 99m- Tc tetrofosmin (SMM) in detection of primary breast cancer. Method: Thirty patients with breast disease were included in study. All of them had clinical investigation, MM, SMM and surgical biopsy for final histological diagnosis. An amount of 600 MBq 99m- Tc tetrofosmin was injected intravenously in the arm opposite to the side of breast lesion. Ten minutes after injection planar breast 7-minutes scans were performed in supine (anterior) and prone (left and right lateral) position. Results: Out of 30 lesion breast cancer was histologically confirmed in 20 (15 ductal invasive, two lobular, one colloid, one papillar carcinoma and one case of cyst sarcoma phylodes- malignant type.) For MM sensitivity of 80%, specificity of 60% and accuracy of 76 % were obtained. At SMM 19/ 20 malignant lesions were detected. Only one false negative result was obtained in 1.0 cm lobular infiltrative cancer, although the smallest detectable lesion measured 0.6 cm. At pathohistology ten lesions presented benign. Four false positive results (two fibroadenomas, one lipogranuloma and one case of fibrocystic disease) were observed, six true negative results in four cases with fibrocystic disease and two fibroadenomas. The overall sensitivity of scintimammography was 95%, specificity 60% and accuracy 83%. Conclusion: We concluded that sensitivity of 99m-Tc tetrofosmin scintimammography in detection of breast cancer is superior to that of mammography. Our results suggest that 99m -Tc tetrofosmin is a suitable tumor seeking agent for breast cancer imaging

  18. Detection of tumor recurrence using technetium99m-tetrofosmin brain SPECT in patients with previously irradiated brain tumors

    International Nuclear Information System (INIS)

    Llamas A; Reyes A; Uribe, L F; Martinez T

    2004-01-01

    Objective: to assess the clinical utility of brain SPECT with Tc-99m Tetrofosmin to differentiate between tumor recurrence and radionecrosis in patients with primary brain tumors previously treated with external beam radiotherapy. Materials and methods: thirteen patients with clinical or radiological suspicion of tumor recurrence were studied with brain SPECT using 20-mCi of Tc-99m Tetrofosmin. Obtained images were interpreted by consensus between two experienced observers and subsequently classified as positive or negative for tumor viability. Results were compared to those of conventional diagnostic imaging techniques. Diagnostic test values and 95% confidence intervals were quantified. Results: SPECT results included 7 true-positives, 5 true-negatives and 1 false negative result. Conclusions: Tc-99m Tetrofosmin brain SPECT night be a useful alternative to diagnose recurrent brain tumors, especially with non-conclusive clinical and radiological findings

  19. First determination of the heart-to-mediastinum ratio using cardiac dual isotope ({sup 123}I-MIBG/{sup 99m}Tc-tetrofosmin) CZT imaging in patients with heart failure: the ADRECARD study

    Energy Technology Data Exchange (ETDEWEB)

    Bellevre, Dimitri; Desmonts, Cedric [CHU Cote de Nacre, Department of Nuclear Medicine, Caen (France); Manrique, Alain; Agostini, Denis [CHU Cote de Nacre, Department of Nuclear Medicine, Caen (France); EA 4650, Normandie Universite, Caen (France); Legallois, Damien [EA 4650, Normandie Universite, Caen (France); CHU Cote de Nacre, Cardiology Department, Caen (France); Bross, Samy; Baavour, Rafael; Roth, Nathaniel [Spectrum Dynamics, Biosensors, Caesarea (Israel); Blaire, Tanguy; Bailliez, Alban [EA 4650, Normandie Universite, Caen (France); IRIS, Polyclinique du Bois, Nuclear Medicine Department, Lille (France)

    2015-11-15

    Cardiac innervation is assessed using the heart-to-mediastinum ratio (HMR) of metaiodobenzylguanidine (MIBG) on planar imaging using Anger single photon emission computed tomography (A-SPECT). The aim of the study was to determine the HMR of MIBG obtained using a CZT-based camera (D-SPECT; Spectrum Dynamics, Israel) in comparison with that obtained using conventional planar imaging. The ADRECARD study prospectively evaluated 44 patients with heart failure. They underwent planar acquisition using the A-SPECT camera 4 h after {sup 123}I-MIBG injection (236.4 ± 39.7 MBq). To localize the heart using D-SPECT, {sup 99m}Tc-tetrofosmin (753 ± 133 MBq) was administered and dual isotope acquisition was performed using the D-SPECT system. HMR was calculated using both planar A-SPECT imaging and front view D-SPECT cine data. In a phantom study, we estimated a model fitting the A-SPECT and the D-SPECT data that was further applied to correct for differences between the cameras. A total of 44 patients (39 men and 5 women, aged 60 ± 11 years) with ischaemic (31 patients) and nonischaemic (13 patients) cardiomyopathy completed the study. Most patients (28 of 44) were NYHA class II, and the mean left ventricular ejection fraction was 33 ± 7 %. The mean HMR values were 1.34 ± 0.15 and 1.45 ± 0.27 from A-SPECT and D-SPECT, respectively (p < 0.0001). After correction, Lin's concordance correlation showed an almost perfect concordance between corrected D-SPECT HMR and A-SPECT HMR, and Bland-Altman analysis demonstrated a high agreement between the two measurements. The ADRECARD study demonstrated that determination of late HMR during cardiac MIBG imaging using dual isotope ({sup 123}I and {sup 99m}Tc) acquisition on a CZT camera (D-SPECT) is feasible in patients with heart failure. A linear correction based on the phantom study yielded a high agreement between {sup 123}I MIBG HMR obtained using a CZT camera and that from conventional planar imaging. (orig.)

  20. Clinical assessment of chest pain and guidelines for imaging

    International Nuclear Information System (INIS)

    Gruettner, J.; Henzler, T.; Sueselbeck, T.; Fink, C.; Borggrefe, M.; Walter, T.

    2012-01-01

    For many emergency facilities, risk assessment of patients with diffuse chest pain still poses a major challenge. In their currently valid recommendations, the international cardiological societies have defined a standardized assessment of the prognostically relevant cardiac risk criteria. Here the classic sequence of basic cardiac diagnostics including case history (cardiac risk factors), physical examination (haemodynamic and respiratory vital parameters), ECG (ST segment analysis) and laboratory risk markers (troponin levels) is paramount. The focus is, on the one hand, on timely indication for percutaneous catheterization, especially in patients at high cardiac risk with or without ST-segment elevation in the ECG, and, on the other hand, on the possibility of safely discharging patients with intermediate or low cardiac risk after non-invasive exclusion of a coronary syndrome. For patients in the intermediate or low risk group, physical or pharmacological stress testing in combination with scintigraphy, echocardiography or magnetic resonance imaging is recommended in addition to basic diagnostics. Moreover, the importance of non-invasive coronary imaging, primarily cardiac CT angiography (CCTA), is increasing. Current data show that in intermediate or low risk patients this method is suitable to reliably rule out coronary heart disease. In addition, attention is paid to the major differential diagnoses of acute coronary syndrome, particularly pulmonary embolism and aortic dissection. Here the diagnostic method of choice is thoracic CT, possibly also in combination with CCTA aiming at a triple rule-out.

  1. Clinical assessment of chest pain and guidelines for imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gruettner, J., E-mail: joachim.gruettner@umm.de [1st Department of Medicine (Cardiology), University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Henzler, T. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Sueselbeck, T. [1st Department of Medicine (Cardiology), University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Fink, C. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Borggrefe, M.; Walter, T. [1st Department of Medicine (Cardiology), University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany)

    2012-12-15

    For many emergency facilities, risk assessment of patients with diffuse chest pain still poses a major challenge. In their currently valid recommendations, the international cardiological societies have defined a standardized assessment of the prognostically relevant cardiac risk criteria. Here the classic sequence of basic cardiac diagnostics including case history (cardiac risk factors), physical examination (haemodynamic and respiratory vital parameters), ECG (ST segment analysis) and laboratory risk markers (troponin levels) is paramount. The focus is, on the one hand, on timely indication for percutaneous catheterization, especially in patients at high cardiac risk with or without ST-segment elevation in the ECG, and, on the other hand, on the possibility of safely discharging patients with intermediate or low cardiac risk after non-invasive exclusion of a coronary syndrome. For patients in the intermediate or low risk group, physical or pharmacological stress testing in combination with scintigraphy, echocardiography or magnetic resonance imaging is recommended in addition to basic diagnostics. Moreover, the importance of non-invasive coronary imaging, primarily cardiac CT angiography (CCTA), is increasing. Current data show that in intermediate or low risk patients this method is suitable to reliably rule out coronary heart disease. In addition, attention is paid to the major differential diagnoses of acute coronary syndrome, particularly pulmonary embolism and aortic dissection. Here the diagnostic method of choice is thoracic CT, possibly also in combination with CCTA aiming at a triple rule-out.

  2. Large-field image intensifiers versus conventional chest radiography: ROC study with simulated interstitial disease

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Waes, P.F.G.M.

    1988-01-01

    Two image intensifier tubes have recently been introduced whose large imaging area makes them suitable for chest imaging (Phillips Pulmodiagnost TLX slit II and Siemens TX 57 large entrance field II). Both modalities present a 10 x 10-cm hard copy image to the radiologist. A receiver operating characteristic (ROC) curve study with simulated interstitial disease was performed to compare the image quality of these image intensifiers with conventional chest images. The relative ranking in terms of decreasing ROC areas was Siemens, conventional, and Philips. Compared with conventional imaging, none of the differences in ROC curve area were statistically significant at the 5% level

  3. Chest MRI

    Science.gov (United States)

    ... resonance imaging - chest; NMR - chest; MRI of the thorax; Thoracic MRI Patient Instructions ... Gotway MB, Panse PM, Gruden JF, Elicker BM. Thoracic radiology. In: Broaddus VC, Mason RJ, Ernst JD, et ...

  4. Neonatal chest image quality addressed through training to enhance radiographer awareness

    Directory of Open Access Journals (Sweden)

    Hesta Friedrich-Nel

    2018-03-01

    Full Text Available Background: Diagnostic radiographers working in the neonatal intensive care unit primarily aim to produce an image of optimal quality using optimal exposure techniques without repeating exposures, to keep neonatal radiation dose to a minimum.   Objectives: The aim of the study was to determine whether radiographers were producing optimal quality chest images and, if not, whether additional training could contribute to reaching this goal in the Free State Province of South Africa.   Methods: Neonatal chest image quality was determined in the Neonatal Intensive Care Unit by using a checklist based on and compiled from published guidelines to evaluate the quality of 450 randomly-selected images. Thereafter, a training programme was designed, based on the evaluation criteria of the checklist and image quality areas identified. The training also referred to positioning techniques that should be applied to ensure optimal image quality. After presentation of the training, 450 newly-produced neonatal chest images were evaluated. These images were selected through purposive sampling as this evaluation only included images of participating radiographers who completed the training.   Results: Image quality that showed significant improvement included a reduction in electrocardiogram lines superimposed on chest anatomy, a tendency to centre closer to thoracic vertebra four, and visible four-sided collimation on images. Image quality areas with no significant enhancement were the absence of lead markers and radiation shielding.   Conclusion: The study has shown that a training programme has the potential to improve neonatal chest image quality.

  5. Fat segmentation on chest CT images via fuzzy models

    Science.gov (United States)

    Tong, Yubing; Udupa, Jayaram K.; Wu, Caiyun; Pednekar, Gargi; Subramanian, Janani Rajan; Lederer, David J.; Christie, Jason; Torigian, Drew A.

    2016-03-01

    Quantification of fat throughout the body is vital for the study of many diseases. In the thorax, it is important for lung transplant candidates since obesity and being underweight are contraindications to lung transplantation given their associations with increased mortality. Common approaches for thoracic fat segmentation are all interactive in nature, requiring significant manual effort to draw the interfaces between fat and muscle with low efficiency and questionable repeatability. The goal of this paper is to explore a practical way for the segmentation of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) components of chest fat based on a recently developed body-wide automatic anatomy recognition (AAR) methodology. The AAR approach involves 3 main steps: building a fuzzy anatomy model of the body region involving all its major representative objects, recognizing objects in any given test image, and delineating the objects. We made several modifications to these steps to develop an effective solution to delineate SAT/VAT components of fat. Two new objects representing interfaces of SAT and VAT regions with other tissues, SatIn and VatIn are defined, rather than using directly the SAT and VAT components as objects for constructing the models. A hierarchical arrangement of these new and other reference objects is built to facilitate their recognition in the hierarchical order. Subsequently, accurate delineations of the SAT/VAT components are derived from these objects. Unenhanced CT images from 40 lung transplant candidates were utilized in experimentally evaluating this new strategy. Mean object location error achieved was about 2 voxels and delineation error in terms of false positive and false negative volume fractions were, respectively, 0.07 and 0.1 for SAT and 0.04 and 0.2 for VAT.

  6. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

    Science.gov (United States)

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R

    2013-07-01

    The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, pchest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.

  7. Comparative uptake of Tc-99m sestamibi and Tc-99m tetrofosmin in cancer cells and tissue expressing P-Glycoprotein or multidrug resistance associated protein

    International Nuclear Information System (INIS)

    Cho, Jung Ah; Lee, Jae Tae; Yoo, Jung Ah

    2005-01-01

    increases in tumoral uptake were not significantly different between MIBI and tetrofosmin for both tumors. MIBI seems to be a better tracer than tetrofosmin for evaluating MDR reversal effect of the modulators in vitro, but these differences were not evident in vivo tumoral uptake. Both MIBI and tetrofosmin seem to be suitable tracers for imaging Pgp-and MRP=mediated drug resistance in tumors

  8. Comparative uptake of Tc-99m sestamibi and Tc-99m tetrofosmin in cancer cells and tissue expressing P-Glycoprotein or multidrug resistance associated protein

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jung Ah; Lee, Jae Tae; Yoo, Jung Ah [School of Medicine, Kyungpook National University, Daegu (Korea, Republic of)] (and others)

    2005-02-15

    240 min with CsA. But increases in tumoral uptake were not significantly different between MIBI and tetrofosmin for both tumors. MIBI seems to be a better tracer than tetrofosmin for evaluating MDR reversal effect of the modulators in vitro, but these differences were not evident in vivo tumoral uptake. Both MIBI and tetrofosmin seem to be suitable tracers for imaging Pgp-and MRP=mediated drug resistance in tumors.

  9. A dual-view digital tomosynthesis imaging technique for improved chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yuncheng; Lai, Chao-Jen; Wang, Tianpeng; Shaw, Chris C., E-mail: cshaw@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054 (United States)

    2015-09-15

    Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values

  10. Analysis of chest image performance in patients with acute chlorine poisoning

    International Nuclear Information System (INIS)

    Liu Liangqing; Zheng Jiangang; Yang Keyu; Wu Honglin; Tang Qingfang; Wu Huiming

    2012-01-01

    Objective: To explore chest image features of patients with acute chlorine poisoning and their clinical values. Methods: A retrospective analysis was performed by chest image features of 117 patients with acute chlorine poisoning. All the patients were classified according to Chinese management of occupational acute chlorine poisoning diagnosis standard. Results: Sixty-five patients presented with stimulus response, and normal or both lungs had a little more white on their chest images. Thirty-one cases presented with minor poisoning, and without or the texture of both lungs was increased, and grew hazy and coarse.seventeen cases were moderate, and small sample vague shadows or single or multiple limitations lamellar shadow. Four cases were serious,and two lungs had extensive and density homogeneous consolidation shadow. Conclusions: It would make the diagnosis and assessment of chlorine poisoning more easier based on the combination of chest image features, the clear history of acute chlorine poisoning and relevant clinical performance. (authors)

  11. [Optimization of digital chest radiography image post-processing in diagnosis of pneumoconiosis].

    Science.gov (United States)

    Sheng, Bing-yong; Mao, Ling; Zhou, Shao-wei; Shi, Jin

    2013-11-01

    To establish the optimal image post-processing parameters for digital chest radiography as preliminary research for introducing digital radiography (DR) to pneumoconiosis diagnosis in China. A total of 204 pneumoconiosis patients and 31 dust-exposed workers were enrolled as the subjects in this research. Film-screen radiography (FSR) and DR images were taken for all subjects. DR films were printed after raw images were processed and parameters were altered using DR workstation (GE Healthcare, U.S.A.). Image gradations, lung textures, and the imaging of thoracic vertebra were evaluated by pneumoconiosis experts, and the optimal post-processing parameters were selected. Optical density was measured for both DR films and FSR films. For the DR machine used in this research, the contrast adjustment (CA) and brightness adjustment (BA) were the main parameters that determine the brightness and gray levels of images. The optimal ranges for CA and BA were 115%∼120% and 160%∼165%, respectively. The quality of DR chest films would be optimized when tissue contrast was adjusted to a maximum of 0.15, edge to a minimum of 1, and both noise reduction and tissue equalization to0.The failure rate of chest DR (0.4%) was significantly lower than that of chest FSR (17%) (P image post-processing on DR machine purchased from GE Healthcare, the DR chest films can meet all requirements for the quality of chest X-ray films in the Chinese diagnostic criteria for pneumoconiosis.

  12. Diagnostic and prognostic value of {sup 99m}Tc-tetrofosmin scintigraphy in maxillofacial flaps

    Energy Technology Data Exchange (ETDEWEB)

    Aigner, Reingard M.; Sorantin, Erich [Department of Radiology, Division of Nuclear Medicine, Karl-Franzens University Graz, Auenbruggerplatz 9, 8036 Graz (Austria); Schultes, Guenter [Department of Oral and Maxillofacial Surgery, Karl-Franzens University Graz (Austria)

    2003-02-01

    In oro-maxillofacial malignancies, new therapeutic approaches are placing changing demands on the diverse diagnostic modalities. In contradistinction to mandibular reconstruction of former years, the transplants (microvascular anastomosed pedicled flaps, ''flaps'') now consist of one or more arteries feeding a soft tissue component attached to a piece of bone suitably fitted to fill the defect. We addressed the diagnostic value of technetium-99m tetrofosmin scintigraphy in differentiating between viability and non-viability of the soft tissue portion of flaps in the immediate postoperative assessment. A total of 60 patients who had received flaps for reconstruction of the mandible after partial resection were investigated with {sup 99m}Tc-tetrofosmin 3-5 days after surgery. Scintigraphy consisted of (a) radionuclide angiography, (b) static planar imaging in four projections starting at 10 min post injection, and (c) single-photon emission tomography (SPET) performed immediately after the planar imaging. Normal perfusion associated with no defects throughout the soft tissue portion of the transplant was observed in 46/60 patients. This scintigraphic pattern was identical to viability and normal postoperative follow-up. Hypoperfusion and small defects on planar and SPET images indicated viability and uncomplicated postoperative healing in 6/60 patients, but non-viability/inadequate healing of the flap in 4/60 patients. Absence of perfusion combined with a large defect on static planar and SPET images definitively showed the non-viability of the flap (4/60 patients). It is concluded that {sup 99m}Tc-tetrofosmin scintigraphy is a sensitive diagnostic tool for the immediate postoperative assessment of the viability and the adequacy of implantation of the soft tissue portion of flaps. Therefore tetrofosmin scintigraphy is an important modality in order (a) to define the optimal therapeutic regimen in the immediate postoperative period and (b) to

  13. Reducing the absorbed dose in analogue radiography of infant chest images by improving the image quality, using image processing techniques

    International Nuclear Information System (INIS)

    Karimian, A.; Yazdani, S.; Askari, M. A.

    2011-01-01

    Radiographic inspection is one of the most widely employed techniques for medical testing methods. Because of poor contrast and high un-sharpness of radiographic image quality in films, converting radiographs to a digital format and using further digital image processing is the best method of enhancing the image quality and assisting the interpreter in their evaluation. In this research work, radiographic films of 70 infant chest images with different sizes of defects were selected. To digitise the chest images and employ image processing the two algorithms (i) spatial domain and (ii) frequency domain techniques were used. The MATLAB environment was selected for processing in the digital format. Our results showed that by using these two techniques, the defects with small dimensions are detectable. Therefore, these suggested techniques may help medical specialists to diagnose the defects in the primary stages and help to prevent more repeat X-ray examination of paediatric patients. (authors)

  14. Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.

    Science.gov (United States)

    Tanaka, Rie

    2016-07-01

    Dynamic chest radiography is a flat-panel detector (FPD)-based functional X-ray imaging, which is performed as an additional examination in chest radiography. The large field of view (FOV) of FPDs permits real-time observation of the entire lungs and simultaneous right-and-left evaluation of diaphragm kinetics. Most importantly, dynamic chest radiography provides pulmonary ventilation and circulation findings as slight changes in pixel value even without the use of contrast media; the interpretation is challenging and crucial for a better understanding of pulmonary function. The basic concept was proposed in the 1980s; however, it was not realized until the 2010s because of technical limitations. Dynamic FPDs and advanced digital image processing played a key role for clinical application of dynamic chest radiography. Pulmonary ventilation and circulation can be quantified and visualized for the diagnosis of pulmonary diseases. Dynamic chest radiography can be deployed as a simple and rapid means of functional imaging in both routine and emergency medicine. Here, we focus on the evaluation of pulmonary ventilation and circulation. This review article describes the basic mechanism of imaging findings according to pulmonary/circulation physiology, followed by imaging procedures, analysis method, and diagnostic performance of dynamic chest radiography.

  15. Quality criteria for chest X-ray image

    International Nuclear Information System (INIS)

    Krieg, R.

    1985-01-01

    A distinction has to be made between invariable and variable criteria in the determination of chest X-ray picture quality criteria. The invariable criteria are defined by the properties of the object and the psychophysiological laws of perception and cognition, and the variable criteria are determined by the prevailing state of the art of technology. An agreement on these criteria is based on the knowledge of the nature and the technical conditions of X-ray picture production and reproduction. The slogan 'the best picture at the lowest dose' dominates, too, the discussion centering around the X-ray picture of the chest, its quality and criteria. (orig./MG) [de

  16. [Development of image quality assurance support system using image recognition technology in radiography in lacked images of chest and abdomen].

    Science.gov (United States)

    Shibuya, Toru; Kato, Kyouichi; Eshima, Hidekazu; Sumi, Shinichirou; Kubo, Tadashi; Ishida, Hideki; Nakazawa, Yasuo

    2012-01-01

    In order to provide a precise radiography for diagnosis, it is required that we avoid radiography with defects by having enough evaluation. Conventionally, evaluation was performed only by observation of a radiological technologist (RT). The evaluation support system was developed for providing a high quality assurance without depending on RT observation only. The evaluation support system, called as the Image Quality Assurance Support System (IQASS), is characterized in that "image recognition technology" for the purpose of diagnostic radiography of chest and abdomen areas. The technique of the system used in this study. Of the 259 samples of posterior-anterior (AP) chest, lateral chest, and upright abdominal x-rays, the sensitivity and specificity was 93.1% and 91.8% in the chest AP, 93.3% and 93.6% in the chest lateral, and 95.0% and 93.8% in the upright abdominal x-rays. In the light of these results, it is suggested that AIQAS could be applied to practical usage for the RT.

  17. Chest wall tuberculosis simulating breast carcinoma: Imaging appearance

    International Nuclear Information System (INIS)

    Goyal, M.; Sharma, R.; Sharma, A.; Swahney, S.; Berry, M.; Chumber, S.

    1998-01-01

    Tuberculosis of the breast is a rare disease. Tubercular abscesses predominantly affecting the soft tissues are also very infrequent. A case of chest wall tuberculosis secondarily involving the breast presenting as a hard, fixed lump simulating mammary carcinoma is presented here. There was no evidence of pleural or pulmonary tuberculosis. Copyright (1998) Blackwell Science Pty Ltd

  18. Studies on image quality and dose exposure in chest radiography in children

    International Nuclear Information System (INIS)

    Schumacher, R.

    1985-01-01

    Chest radiography accounts for almost 50% of all radiographies in radiological departments for children, thus clearly dominating X-ray performances. The indications for examination in children are frequent infections of the upper airways, congenital cardiac defects, and controls in oncological patients. By contrast, indications for radioscopy of the chest organs which figure greatly in adult age and are often required concurrently with every chest radiography, are rather rare in the patient group of a paediatric X-ray department with their rate of c. 0.5% related to chest radiography. Chest radiographs and phantom radiographs were produced using different techniques and were compared by means of subjective and objective image quality parameters. Concurrently, thermoluminescence dosimetry was used to perform dose measurements of the small gonadal dose occurring in patients in chest radiographies. The study aimed at finding a chest radiography technique appropriate for use in paediatric radiology while considering both image quality parameters and the radiation dose required for producing pictures. (orig./DG) [de

  19. Imaging of blunt chest trauma; Bildgebung des stumpfen Thoraxtraumas

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, H. [Medizinische Universitaet Wien, Allgemeines Krankenhaus, Univ.-Klinik fuer Radiologie und Nuklearmedizin, Wien (Austria); Negrin, L. [Medizinische Universitaet Wien, Allgemeines Krankenhaus, Univ.-Klinik fuer Unfallchirurgie, Wien (Austria)

    2014-09-15

    Blunt chest trauma is associated with high morbidity and mortality. Consequently, all patients should be evaluated radiologically after blunt chest trauma to allow timely and appropriate treatment. Conventional chest radiographs and computed tomography (CT) are proven modalities with which to evaluate patients after blunt chest trauma. Over the last several years extended focused assessment with sonography for trauma (eFAST) has gained increasing importance for the initial assessment of seriously injured patients. In the acute phase of severely injured patients eFAST examinations are helpful to exclude pneumothorax, hemothorax and hemopericardium. Chest radiographs may also be used to diagnose a pneumothorax or hemothorax; however, the sensitivity is limited and CT is the diagnostic modality of choice to evaluate severely injured patients. (orig.) [German] Stumpfe Thoraxtraumen gehen mit einer hohen Morbiditaet und Mortalitaet einher. Daher sollten Patienten mit Verdacht auf ein stumpfes Thoraxtrauma rasch radiologisch untersucht werden, damit die entsprechenden therapeutischen Schritte zeitgerecht eingeleitet werden koennen. Zur Abklaerung von Patienten nach einem stumpfen Thoraxtrauma sind seit Jahren das konventionelle Lungenroentgen und die Computertomographie bewaehrte Verfahren. In den letzten Jahren hat die fokussierte Ultraschalluntersuchung (eFAST, Extended Focused Assessment with Sonography for Trauma) von schwerverletzten Patienten vermehrt an Bedeutung gewonnen. Durch eine eFAST-Untersuchung kann in der Akutphase rasch geklaert werden, ob bei dem Patienten ein therapiebeduerftiger Pneumothorax, Haematoperikard oder Haematothorax vorliegen. Auch das Lungenroentgen wird zur Diagnose eines Pneumothorax oder Haematothorax eingesetzt, wenngleich seine Sensitivitaet deutlich eingeschraenkt ist. Die CT ist das diagnostische Verfahren der Wahl, um v. a. Patienten mit einem schweren Thoraxtrauma abzuklaeren. (orig.)

  20. Imaging of chest trauma: radiological patterns of injury and diagnostic algorithms

    International Nuclear Information System (INIS)

    Lomoschitz, Fritz M.; Eisenhuber, Edith; Linnau, Ken F.; Peloschek, Philipp; Schoder, Maria; Bankier, Alexander A.

    2003-01-01

    In patients after chest trauma, imaging plays a key role for both, the primary diagnostic work-up, and the secondary assessment of potential treatment. Despite its well-known limitations, the anteroposterior chest radiograph remains the starting point of the imaging work-up. Adjunctive imaging with computed tomography, that recently is increasingly often performed on multidetector computed tomography units, adds essential information not readily available on the conventional radiograph. This allows better definition of trauma-associated thoracic injuries not only in acute traumatic aortic injury, but also in pulmonary, tracheobronchial, cardiac, diaphragmal, and thoracic skeletal injuries. This article reviews common radiographic findings in patients after chest trauma, shows typical imaging features resulting from thoracic injury, presents imaging algorithms, and recalls to the reader less common but clinically relevant entities encountered in patients after thoracic trauma

  1. Evaluation and comparison of signal to noise ratio according to histogram equalization of heart shadow on chest image

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Lee, Eul Kyu [Inje Paik University Hospital at Jeo-dong, Seoul (Korea, Republic of); Jeong, Hoi Woun [The Baekseok Culture University, Cheonan (Korea, Republic of); Kang, Byung Sam; Kim, Hyun Soo; Min, Jung Whan; Son, Jin Hyun [The Shingu University, Seongnam (Korea, Republic of)

    2017-06-15

    The purpose of this study was to measure signal to noise ratio (SNR) according to change of equalization from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 87 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using Image. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p < 0.05). In SNR results, with the quality of distributions in the order of original chest image, original chest image heart shadow and equalization chest image, equalization chest image heart shadow(p < 0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the histogram equalization chest image.

  2. Evaluation and comparison of signal to noise ratio according to histogram equalization of heart shadow on chest image

    International Nuclear Information System (INIS)

    Kim, Ki Won; Lee, Eul Kyu; Jeong, Hoi Woun; Kang, Byung Sam; Kim, Hyun Soo; Min, Jung Whan; Son, Jin Hyun

    2017-01-01

    The purpose of this study was to measure signal to noise ratio (SNR) according to change of equalization from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 87 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using Image. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p < 0.05). In SNR results, with the quality of distributions in the order of original chest image, original chest image heart shadow and equalization chest image, equalization chest image heart shadow(p < 0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the histogram equalization chest image

  3. Cardiac CT for the assessment of chest pain: Imaging techniques and clinical results

    International Nuclear Information System (INIS)

    Becker, Hans-Christoph; Johnson, Thorsten

    2012-01-01

    Immediate and efficient risk stratification and management of patients with acute chest pain in the emergency department is challenging. Traditional management of these patients includes serial ECG, laboratory tests and further on radionuclide perfusion imaging or ECG treadmill testing. Due to the advances of multi-detector CT technology, dedicated coronary CT angiography provides the potential to rapidly and reliably diagnose or exclude acute coronary artery disease. Life-threatening causes of chest pain, such as aortic dissection and pulmonary embolism can simultaneously be assessed with a single scan, sometimes referred to as “triple rule out” scan. With appropriate patient selection, cardiac CT can accurately diagnose heart disease or other sources of chest pain, markedly decrease health care costs, and reliably predict clinical outcomes. This article reviews imaging techniques and clinical results for CT been used to evaluate patients with chest pain entering the emergency department.

  4. Performance evaluation of image denoising developed using convolutional denoising autoencoders in chest radiography

    Science.gov (United States)

    Lee, Donghoon; Choi, Sunghoon; Kim, Hee-Joung

    2018-03-01

    When processing medical images, image denoising is an important pre-processing step. Various image denoising algorithms have been developed in the past few decades. Recently, image denoising using the deep learning method has shown excellent performance compared to conventional image denoising algorithms. In this study, we introduce an image denoising technique based on a convolutional denoising autoencoder (CDAE) and evaluate clinical applications by comparing existing image denoising algorithms. We train the proposed CDAE model using 3000 chest radiograms training data. To evaluate the performance of the developed CDAE model, we compare it with conventional denoising algorithms including median filter, total variation (TV) minimization, and non-local mean (NLM) algorithms. Furthermore, to verify the clinical effectiveness of the developed denoising model with CDAE, we investigate the performance of the developed denoising algorithm on chest radiograms acquired from real patients. The results demonstrate that the proposed denoising algorithm developed using CDAE achieves a superior noise-reduction effect in chest radiograms compared to TV minimization and NLM algorithms, which are state-of-the-art algorithms for image noise reduction. For example, the peak signal-to-noise ratio and structure similarity index measure of CDAE were at least 10% higher compared to conventional denoising algorithms. In conclusion, the image denoising algorithm developed using CDAE effectively eliminated noise without loss of information on anatomical structures in chest radiograms. It is expected that the proposed denoising algorithm developed using CDAE will be effective for medical images with microscopic anatomical structures, such as terminal bronchioles.

  5. Image quality in conventional chest radiography. Evaluation using the postprocessing tool Diamond View

    International Nuclear Information System (INIS)

    Niemann, Tilo; Reisinger, Clemens; Rau, Philipp; Schwarz, Jochen; Ruis-Lopez, Laura; Bongartz, Georg

    2010-01-01

    The objective of this work was to evaluate the influence of the postprocessing tool Diamond View (Siemens AG Medical Solutions, Germany) on image quality in conventional chest radiography. Evaluation of image quality remains a challenge in conventional radiography. Based on the European Commission quality criteria we evaluated the improvement of image quality when applying the new postprocessing tool Diamond View (Siemens AG Medical solutions, Germany) to conventional chest radiographs. Three different readers prospectively evaluated 102 digital image pairs of chest radiographs. Statistical analysis was performed with a p value <0.05 considered as significant. Images were evaluated on basis of the modified imaging Quality Criteria by the Commission of the European Communities. Each of the 11 image quality criteria was evaluated separately using a five point classification. Statistical analysis showed an overall tendency for improved image quality for Diamond View (DV) for all criteria. Significant differences could be found in most of the criteria. In conclusion DV improves image quality in conventional chest radiographs.

  6. The use of {sup 99m} Tc-tetrofosmin in the hyperparathyroidism caused by parathyroid adenoma; Utilidade do {sup 99m} Tc-tetrofosmin no hiperparatireoidismo causado por adenoma de paratireoide

    Energy Technology Data Exchange (ETDEWEB)

    Calegaro, Jose Ulisses Manzini; Queiroz, Danicia Lobao; Barra Sobrinho, Alaor; Duarte, Lidia Vania de Moura; Gomes, Enio de Freitas; Almeida, Mario Sergio Severino de; Barcelos, Grecyane Lopes; Malheiros, Alessandra Maria Tavares; Ulyssea, Rogerio [Hospital de Base do Distrito Federal, Brasilia, DF (Brazil)

    1998-12-01

    The aim of this study was to verify the clinical condition of our patients with parathyroid adenoma an to evaluate the diagnostic value of {sup 99} Tc-tetrofosmin in its preoperative location. The authors reported 6 cases (3 males) with ages between 17 and 63 years old, 4 with bone manifestations, one with repetitive urinary lithyasis and another with peptic ulcer and obesity, showing alternations in calcium metabolism and increased P T H. They were submitted to parathyroid scintigraphy after intravenous injection of {sup 99m} Tc-tetrofosmin (20 m Ci; 740 MBq), with obtention of sequential images (10, 60, 120 minutes) in a gamma-camera with large field of detection. THe scintigraphy showed preferential uptake of the tracer in the inferior right lobe (2 cases) and in the inferior left lobe (4 cases) of thyroid, with total location agreement in the surgery. The histological study was parathyroid adenoma in all cases. These results emphasize the clinical necessity of a more initial diagnosis of primary hyperparathyroidism and it is possible to day that the metabolism of tetrofosmin is quite similar to sestamibi. Tetrofosmin can be used in parathyroid scintigraphy routinely. (author) 25 refs., 3 figs.

  7. Application of Super-Resolution Convolutional Neural Network for Enhancing Image Resolution in Chest CT.

    Science.gov (United States)

    Umehara, Kensuke; Ota, Junko; Ishida, Takayuki

    2017-10-18

    In this study, the super-resolution convolutional neural network (SRCNN) scheme, which is the emerging deep-learning-based super-resolution method for enhancing image resolution in chest CT images, was applied and evaluated using the post-processing approach. For evaluation, 89 chest CT cases were sampled from The Cancer Imaging Archive. The 89 CT cases were divided randomly into 45 training cases and 44 external test cases. The SRCNN was trained using the training dataset. With the trained SRCNN, a high-resolution image was reconstructed from a low-resolution image, which was down-sampled from an original test image. For quantitative evaluation, two image quality metrics were measured and compared to those of the conventional linear interpolation methods. The image restoration quality of the SRCNN scheme was significantly higher than that of the linear interpolation methods (p < 0.001 or p < 0.05). The high-resolution image reconstructed by the SRCNN scheme was highly restored and comparable to the original reference image, in particular, for a ×2 magnification. These results indicate that the SRCNN scheme significantly outperforms the linear interpolation methods for enhancing image resolution in chest CT images. The results also suggest that SRCNN may become a potential solution for generating high-resolution CT images from standard CT images.

  8. Application of Deconvolution Algorithm of Point Spread Function in Improving Image Quality: An Observer Preference Study on Chest Radiography.

    Science.gov (United States)

    Chae, Kum Ju; Goo, Jin Mo; Ahn, Su Yeon; Yoo, Jin Young; Yoon, Soon Ho

    2018-01-01

    To evaluate the preference of observers for image quality of chest radiography using the deconvolution algorithm of point spread function (PSF) (TRUVIEW ART algorithm, DRTECH Corp.) compared with that of original chest radiography for visualization of anatomic regions of the chest. Prospectively enrolled 50 pairs of posteroanterior chest radiographs collected with standard protocol and with additional TRUVIEW ART algorithm were compared by four chest radiologists. This algorithm corrects scattered signals generated by a scintillator. Readers independently evaluated the visibility of 10 anatomical regions and overall image quality with a 5-point scale of preference. The significance of the differences in reader's preference was tested with a Wilcoxon's signed rank test. All four readers preferred the images applied with the algorithm to those without algorithm for all 10 anatomical regions (mean, 3.6; range, 3.2-4.0; p chest anatomical structures applied with the deconvolution algorithm of PSF was superior to the original chest radiography.

  9. Value of the asymmetric film-screen system InSight HC in chest imaging

    International Nuclear Information System (INIS)

    Haeussler, M.D.; Lenzen, H.; Reckels, C.; Peters, P.E.

    1994-01-01

    The asymmetric film-screen system InSight HC represents a development to optimize chest imaging. The purpose of the study was to compare the exposure range and the image quality of this new system with a conventional film-screen system. The optical density of images in both techniques was measured and the image quality of 100 chest images from 50 intensive-care patients was evaluated. 4 observers graded the image quality of organic, non-organic and pathological structures. Statistical evaluation was performed by interobserver analysis. The asymmetric film-screen system shows a larger exposure range and a superior image quality in the mediastinal field. The image quality in the peripheral field must be judged critically and improved especially because of the poor recognizability of pneumothoraces. (orig.) [de

  10. Conversion to use of digital chest images for surveillance of coal workers' pneumoconiosis (black lung).

    Science.gov (United States)

    Levine, Betty A; Ingeholm, Mary Lou; Prior, Fred; Mun, Seong K; Freedman, Matthew; Weissman, David; Attfield, Michael; Wolfe, Anita; Petsonk, Edward

    2009-01-01

    To protect the health of active U.S. underground coal miners, the National Institute for Occupational Safety and Health (NIOSH) has a mandate to carry out surveillance for coal workers' pneumoconiosis, commonly known as Black Lung (PHS 2001). This is accomplished by reviewing chest x-ray films obtained from miners at approximately 5-year intervals in approved x-ray acquisition facilities around the country. Currently, digital chest images are not accepted. Because most chest x-rays are now obtained in digital format, NIOSH is redesigning the surveillance program to accept and manage digital x-rays. This paper highlights the functional and security requirements for a digital image management system for a surveillance program. It also identifies the operational differences between a digital imaging surveillance network and a clinical Picture Archiving Communication Systems (PACS) or teleradiology system.

  11. Improved detection of focal pneumonia by chest radiography with bone suppression imaging

    International Nuclear Information System (INIS)

    Li, Feng; Engelmann, Roger; Pesce, Lorenzo; Armato, Samuel G.; MacMahon, Heber

    2012-01-01

    To evaluate radiologists' ability to detect focal pneumonia by use of standard chest radiographs alone compared with standard plus bone-suppressed chest radiographs. Standard chest radiographs in 36 patients with 46 focal airspace opacities due to pneumonia (10 patients had bilateral opacities) and 20 patients without focal opacities were included in an observer study. A bone suppression image processing system was applied to the 56 radiographs to create corresponding bone suppression images. In the observer study, eight observers, including six attending radiologists and two radiology residents, indicated their confidence level regarding the presence of a focal opacity compatible with pneumonia for each lung, first by use of standard images, then with the addition of bone suppression images. Receiver operating characteristic (ROC) analysis was used to evaluate the observers' performance. The mean value of the area under the ROC curve (AUC) for eight observers was significantly improved from 0.844 with use of standard images alone to 0.880 with standard plus bone suppression images (P < 0.001) based on 46 positive lungs and 66 negative lungs. Use of bone suppression images improved radiologists' performance for detection of focal pneumonia on chest radiographs. (orig.)

  12. Improved detection of focal pneumonia by chest radiography with bone suppression imaging

    Energy Technology Data Exchange (ETDEWEB)

    Li, Feng; Engelmann, Roger; Pesce, Lorenzo; Armato, Samuel G.; MacMahon, Heber [University of Chicago, Department of Radiology, MC-2026, Chicago, IL (United States)

    2012-12-15

    To evaluate radiologists' ability to detect focal pneumonia by use of standard chest radiographs alone compared with standard plus bone-suppressed chest radiographs. Standard chest radiographs in 36 patients with 46 focal airspace opacities due to pneumonia (10 patients had bilateral opacities) and 20 patients without focal opacities were included in an observer study. A bone suppression image processing system was applied to the 56 radiographs to create corresponding bone suppression images. In the observer study, eight observers, including six attending radiologists and two radiology residents, indicated their confidence level regarding the presence of a focal opacity compatible with pneumonia for each lung, first by use of standard images, then with the addition of bone suppression images. Receiver operating characteristic (ROC) analysis was used to evaluate the observers' performance. The mean value of the area under the ROC curve (AUC) for eight observers was significantly improved from 0.844 with use of standard images alone to 0.880 with standard plus bone suppression images (P < 0.001) based on 46 positive lungs and 66 negative lungs. Use of bone suppression images improved radiologists' performance for detection of focal pneumonia on chest radiographs. (orig.)

  13. Computed and conventional chest radiography: a comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Ramli, K.; Abdullah, B.J.J.; Ng, K-H.; Hussain, A.F.; Mahmud, R.

    2005-01-01

    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P>0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (χ 2 tests) Copyright (2005) Blackwell Publishing Asia Pty Ltd

  14. Improvement of the clinical use of computed radiography for mobile chest imaging: Image quality and patient dose

    Science.gov (United States)

    Rill, Lynn Neitzey

    Chest radiography is technically difficult because of the wide variation of tissue attenuations in the chest and limitations of screen-film systems. Mobile chest radiography, performed bedside on hospital inpatients, presents additional difficulties due to geometrical and equipment limitations inherent to mobile x-ray procedures and the severity of illness in patients. Computed radiography (CR) offers a new approach for mobile chest radiography by utilizing a photostimulable phosphor. Photostimulable phosphors are more efficient in absorbing lower-energy x-rays than standard intensifying screens and overcome some image quality limitations of mobile chest imaging, particularly because of the inherent latitude. This study evaluated changes in imaging parameters for CR to take advantage of differences between CR and screen-film radiography. Two chest phantoms, made of acrylic and aluminum, simulated x-ray attenuation for average-sized and large- sized adult chests. The phantoms contained regions representing the lungs, heart and subdiaphragm. Acrylic and aluminum disks (1.9 cm diameter) were positioned in the chest regions to make signal-to-noise ratio (SNR) measurements for different combinations of imaging parameters. Disk thicknesses (contrast) were determined from disk visibility. Effective dose to the phantom was also measured for technique combinations. The results indicated that using an anti-scatter grid and lowering x- ray tube potential improved the SNR significantly; however, the dose to the phantom also increased. An evaluation was performed to examine the clinical applicability of the observed improvements in SNR. Parameter adjustments that improved phantom SNRs by more than 50% resulted in perceived image quality improvements in the lung region of clinical mobile chest radiographs. Parameters that produced smaller improvements in SNR had no apparent effect on clinical image quality. Based on this study, it is recommended that a 3:1 grid be used for

  15. Dynamic Chest Image Analysis: Model-Based Perfusion Analysis in Dynamic Pulmonary Imaging

    Directory of Open Access Journals (Sweden)

    Kiuru Aaro

    2003-01-01

    Full Text Available The "Dynamic Chest Image Analysis" project aims to develop model-based computer analysis and visualization methods for showing focal and general abnormalities of lung ventilation and perfusion based on a sequence of digital chest fluoroscopy frames collected with the dynamic pulmonary imaging technique. We have proposed and evaluated a multiresolutional method with an explicit ventilation model for ventilation analysis. This paper presents a new model-based method for pulmonary perfusion analysis. According to perfusion properties, we first devise a novel mathematical function to form a perfusion model. A simple yet accurate approach is further introduced to extract cardiac systolic and diastolic phases from the heart, so that this cardiac information may be utilized to accelerate the perfusion analysis and improve its sensitivity in detecting pulmonary perfusion abnormalities. This makes perfusion analysis not only fast but also robust in computation; consequently, perfusion analysis becomes computationally feasible without using contrast media. Our clinical case studies with 52 patients show that this technique is effective for pulmonary embolism even without using contrast media, demonstrating consistent correlations with computed tomography (CT and nuclear medicine (NM studies. This fluoroscopical examination takes only about 2 seconds for perfusion study with only low radiation dose to patient, involving no preparation, no radioactive isotopes, and no contrast media.

  16. Reverse redistribution phenomenon on rest 99mTc-tetrofosmin myocardial single photon emission computed tomography involves impaired left ventricular contraction in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Kurokawa, Kazuyuki; Ohte, Nobuyuki; Miyabe, Hiromichi; Akita, Sachie; Yajima, Kazuhiro; Hayano, Junichiro; Kimura, Genjiro

    2003-01-01

    The purpose of this study was to investigate the clinical significance of the reverse redistribution (RR) phenomenon on technetium-99m ( 99m Tc)-tetrofosmin myocardial single photon emission computed tomography (SPECT) performed at rest. Twenty-five patients underwent myocardial SPECT 3 weeks after the onset of acute myocardial infarction. Myocardial images were acquired at 40 min (early) and 4 h (delayed) after the injection of 740 MBq of 99m Tc-tetrofosmin. The regional myocardial uptake of the tracer in 26 segments of the left ventricular (LV) wall was visually scored from 0 (no activity) to 3 (normal activity), and then the RR was defined as a decrease of more than 1 point in the activity score on the delayed image compared with that on the early image. Regions with an activity score of 3 on both the early and delayed images were defined as normal, and those with a score of 0 or 1 on the early image were considered to have a fixed defect. The regional myocardial 99m Tc-tetrofosmin uptake and washout rate were also quantitatively assessed in each region. In addition, exercise stress electrocardiograph-gated SPECT with 99m Tc-tetrofosmin was performed within 1 week of the rest study, and the percent count increase (%CI) during myocardial contraction in each corresponding region was studied. RR was observed in 18 of the 25 patients. The regional washout rate of 99m Tc-tetrofosmin was significantly higher in the RR regions (45.0±3.8%) than in either the normal regions (36.4±4.1%, p 99m Tc-tetrofosmin SPECT have severely impaired LV wall contraction after exercise. (author)

  17. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system

    International Nuclear Information System (INIS)

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R; Avery, G; Balcam, S; Needler, L

    2014-01-01

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQ m ), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQ m  and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma. (paper)

  18. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    Science.gov (United States)

    Moore, C S; Wood, T J; Avery, G; Balcam, S; Needler, L; Beavis, A W; Saunderson, J R

    2014-05-07

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.

  19. Chest imaging in aids - radiological findings with pathologic correlation: review article

    International Nuclear Information System (INIS)

    Qazi, A.S.

    1999-01-01

    Majority of life threatening illnesses in AIDS begin as pulmonary infections and a radiologist must always seriously consider the possibility of HIV infection and its manifestation when confronting an abnormal chest study in a young adult. Chest radiography may be normal in up to 15% of patients with proven pulmonary involvement or the radiographic picture may be confusing due to atypical appearances of opportunistic infections in immuno-compromised host, compounded further by concomitant appearance of neoplastic complications like Kaposi AIDS relate lymphoma. Cases with normal chest radiograph but high degree of suspicion of chest disease need to be evaluated by CT scan which has been found to be superior to chest radiography in identifying patient with and without chest disease and in the differential diagnosis of pulmonary complications in patients with AIDS. Radio nuclear scans and MRI have some role only in selected few cases. Combining imaging features with clinical presentation, CD4 lymphocyte count, previous treatment and underlying risk group can narrow down differential diagnosis, expedite treatment and may be helpful in preventing complications. (author)

  20. Evaluation of the image quality of chest CT scans: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Martins N, P. I.; Prata M, A., E-mail: priscillainglid@gmail.com [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) is considered one of the most important methods of medical imaging employed nowadays, due to its non-invasiveness and the high quality of the images it is able to generate. However, the diagnostic radiation dose received by an individual over the year often exceeds the dose received on account of background radiation. Therefore, it is important to know and to control the dose distribution in the patient by varying the image acquisition parameters. The aim of this study is to evaluate the variation of the image quality of chest CT scans performed by two phantoms. In this paper, a cylindrical Polymethyl Methacrylate (PMMA) chest phantom was used and a second PMMA phantom has been developed with the same volume but an oblong shape, based on the actual dimensions of a male human thorax, in the axillary region. Ten-centimeter scans of the central area of each phantom were performed by a 16-channel Toshiba CT scanner, model Alexion. The scanning protocol employed was the radiology service protocol for chest scans. The noise survey was conducted within the image of the center slice, in five regions: one central and four peripheral areas close to the edge of the object (anterior, posterior, left and right). The recorded values showed that the oblong phantom, with a shape that is more similar to the actual human chest, has a considerably smaller noise, especially in the anterior, posterior and central regions. (Author)

  1. Evaluation of the image quality of chest CT scans: a phantom study

    International Nuclear Information System (INIS)

    Martins N, P. I.; Prata M, A.

    2016-10-01

    Computed tomography (CT) is considered one of the most important methods of medical imaging employed nowadays, due to its non-invasiveness and the high quality of the images it is able to generate. However, the diagnostic radiation dose received by an individual over the year often exceeds the dose received on account of background radiation. Therefore, it is important to know and to control the dose distribution in the patient by varying the image acquisition parameters. The aim of this study is to evaluate the variation of the image quality of chest CT scans performed by two phantoms. In this paper, a cylindrical Polymethyl Methacrylate (PMMA) chest phantom was used and a second PMMA phantom has been developed with the same volume but an oblong shape, based on the actual dimensions of a male human thorax, in the axillary region. Ten-centimeter scans of the central area of each phantom were performed by a 16-channel Toshiba CT scanner, model Alexion. The scanning protocol employed was the radiology service protocol for chest scans. The noise survey was conducted within the image of the center slice, in five regions: one central and four peripheral areas close to the edge of the object (anterior, posterior, left and right). The recorded values showed that the oblong phantom, with a shape that is more similar to the actual human chest, has a considerably smaller noise, especially in the anterior, posterior and central regions. (Author)

  2. Super-resolution convolutional neural network for the improvement of the image quality of magnified images in chest radiographs

    Science.gov (United States)

    Umehara, Kensuke; Ota, Junko; Ishimaru, Naoki; Ohno, Shunsuke; Okamoto, Kentaro; Suzuki, Takanori; Shirai, Naoki; Ishida, Takayuki

    2017-02-01

    Single image super-resolution (SR) method can generate a high-resolution (HR) image from a low-resolution (LR) image by enhancing image resolution. In medical imaging, HR images are expected to have a potential to provide a more accurate diagnosis with the practical application of HR displays. In recent years, the super-resolution convolutional neural network (SRCNN), which is one of the state-of-the-art deep learning based SR methods, has proposed in computer vision. In this study, we applied and evaluated the SRCNN scheme to improve the image quality of magnified images in chest radiographs. For evaluation, a total of 247 chest X-rays were sampled from the JSRT database. The 247 chest X-rays were divided into 93 training cases with non-nodules and 152 test cases with lung nodules. The SRCNN was trained using the training dataset. With the trained SRCNN, the HR image was reconstructed from the LR one. We compared the image quality of the SRCNN and conventional image interpolation methods, nearest neighbor, bilinear and bicubic interpolations. For quantitative evaluation, we measured two image quality metrics, peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). In the SRCNN scheme, PSNR and SSIM were significantly higher than those of three interpolation methods (pmethods without any obvious artifacts. These preliminary results indicate that the SRCNN scheme significantly outperforms conventional interpolation algorithms for enhancing image resolution and that the use of the SRCNN can yield substantial improvement of the image quality of magnified images in chest radiographs.

  3. Two K versus 4 K storage phosphor chest radiography: detection performance and image quality

    NARCIS (Netherlands)

    Koelblinger, Claus; Prokop, Mathias; Weber, Michael; Sailer, Johannes; Cartes-Zumelzu, Fabiola; Schaefer-Prokop, Cornelia

    2007-01-01

    The purpose of this study was to evaluate the effect of matrix size (4-K versus 2-K) in digital storage phosphor chest radiographs on image quality and on the detection of CT-proven thoracic abnormalities. In 85 patients who underwent a CT of the thorax, we obtained two additional posteroanterior

  4. Cross-sectional imaging with CT and/or MRI of pediatric chest tumors

    International Nuclear Information System (INIS)

    Wyttenbach, R.; Vock, P.; Tschaeppeler, H.

    1998-01-01

    The purpose of this study was to provide an overview of the spectrum of pediatric chest masses, to present the results of cross-sectional imaging with CT and/or MRI, and to define diagnostic criteria to limit differential diagnosis. Seventy-eight children with thoracic mass lesions were retrospectively evaluated using CT (72 patients) and/or MR imaging (12 patients). All masses were evaluated for tissue characteristics (attenuation values or signal intensity, enhancement, and calcification) and were differentiated according to age, gender, location, and etiology. Twenty-eight of 38 (74 %) mediastinal masses were malignant (neuroblastoma, malignant lymphoma). Thirty of 38 (79 %) pulmonary masses were metastatic in origin, all with an already known primary tumor (osteosarcoma, Wilms tumor). With one exception, all remaining pulmonary lesions were benign. Seventeen of 21 (81 %) chest wall lesions were malignant (Ewing sarcoma, primitive neuroectodermal tumor). The majority of mediastinal and chest wall tumors in children is malignant. Lung lesions are usually benign, unless a known extrapulmonary tumor suggests pulmonary metastases. Cross-sectional imaging with CT and/or MRI allows narrowing of the differential diagnosis of pediatric chest masses substantially by defining the origin and tissue characteristics. Magnetic resonance imaging is preferred for posterior mediastinal lesions, whereas CT should be used for pulmonary lesions. For the residual locations both modalities are complementary. (orig.)

  5. Persistent chest pain following oral dipyridamole for thallium 201 myocardial imaging

    International Nuclear Information System (INIS)

    Kwai, A.H.; Jacobson, A.F.; McIntyre, K.M.; Williams, W.H.; Tow, D.E.

    1990-01-01

    A patient was admitted to the hospital with acute chest pain. After acute myocardial infarction was ruled out, he underwent a stress thallium 201 scintigraphy using oral dipyridamole and developed persistent angina with sedimentation time segement elevation. This complication has not been reported previously. It is recommended that appropriate intervention be available if severe ischemia develops following administration of dipyridamole for diagnostic imaging. (orig.)

  6. Development and validation of a psychometric scale for assessing PA chest image quality: A pilot study

    International Nuclear Information System (INIS)

    Mraity, H.; England, A.; Akhtar, I.; Aslam, A.; De Lange, R.; Momoniat, H.; Nicoulaz, S.; Ribeiro, A.; Mazhir, S.; Hogg, P.

    2014-01-01

    Purpose: To develop and validate a psychometric scale for assessing image quality perception for chest X-ray images. Methods: Bandura's theory was used to guide scale development. A review of the literature was undertaken to identify items/factors which could be used to evaluate image quality using a perceptual approach. A draft scale was then created (22 items) and presented to a focus group (student and qualified radiographers). Within the focus group the draft scale was discussed and modified. A series of seven postero-anterior chest images were generated using a phantom with a range of image qualities. Image quality perception was confirmed for the seven images using signal-to-noise ratio (SNR 17.2–36.5). Participants (student and qualified radiographers and radiology trainees) were then invited to independently score each of the seven images using the draft image quality perception scale. Cronbach alpha was used to test interval reliability. Results: Fifty three participants used the scale to grade image quality perception on each of the seven images. Aggregated mean scale score increased with increasing SNR from 42.1 to 87.7 (r = 0.98, P < 0.001). For each of the 22 individual scale items there was clear differentiation of low, mid and high quality images. A Cronbach alpha coefficient of >0.7 was obtained across each of the seven images. Conclusion: This study represents the first development of a chest image quality perception scale based on Bandura's theory. There was excellent correlation between the image quality perception scores derived using the scale and the SNR. Further research will involve a more detailed item and factor analysis

  7. Objective quantification of pulmonary effects in X-ray chest images

    International Nuclear Information System (INIS)

    Oliveira, Marcela de; Giacomini, Guilherme; Alvarez, Matheus; Pereira, Paulo M.C.; Ribeiro, Sergio M.; Pina, Diana R. de

    2016-01-01

    Tuberculosis (TB) is an infectious lung disease of great concern worldwide. Even after treatment, TB leaves pulmonary sequelae that compromise the quality of life of patients. The exam of diagnostic imaging done more frequently is the X-ray chest. The evaluation of pulmonary involvement of these patients is performed visually by the radiologist. The detection and quantification aided by computer systems are of great importance for the more accurate assessment of pulmonary involvement. The objective of this study was to evaluate computationally the reduction of lung damage in X-ray of chest in patients treated with two different medication regimens. (author)

  8. Dose-image quality study in digital chest radiography using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Silva, A.X.; Lopes, R.T.; Yoriyaz, H.

    2008-01-01

    One of the main preoccupations of diagnostic radiology is to guarantee a good image-sparing dose to the patient. In the present study, Monte Carlo simulations, with MCNPX code, coupled with an adult voxel female model (FAX) were performed to investigate how image quality and dose in digital chest radiography vary with tube voltage (80-150 kV) using air-gap technique and a computed radiography system. Calculated quantities were normalized to a fixed value of entrance skin exposure (ESE) of 0.0136 R. The results of the present analysis show that the image quality for chest radiography with imaging plate is improved and the dose reduced at lower tube voltage

  9. Image quality of a Konica Regius 336 digital system in chest radiography

    International Nuclear Information System (INIS)

    Ostinelli, A.; Frigerio, M.; Monti, A.F.; Gelosa, S.; Tognoli, P.; Perniola, N.; Gozzi, G.

    2000-01-01

    Digital radiographic systems permit to optimize execution, depiction and storage of radiological images. Since a Regius 336 digital system (Konica Corp. Tokyo, Japan) devoted to chest radiography Department of S. Anna Hospital in Como, Italy, it was investigated its performance relative to image quality. Konica Regius 336 is a computed radiography system made of a phosphorescence detector plate which is scanned with an infrared semiconductor laser beam. The radiographic image obtained from the detector is subjected to image processing, which allows a stable output and the nonlinear curve typical of conventional radiographic systems. Image quality was assessed based on the following parameters: dose, contrast, noise and spatial resolution. As reference, it was assessed the same parameters on a Cronex 88 analogic chest-changer (DuPont Pharma, North Billerica, Mass, USA). The Regius 336 air kerma values were always higher than the analogic ones (about 10%), both with and without a chest phantom; noise was also greater than in analogic images, sometimes even doubled. The optical densities of a step wedge and the spatial resolution of the digital chest-changer are independent of the X-ray tube voltage consequent to broader optical latitude. Inversely, the analogic images of the wedges show great optical density variability as a function of the X-ray tube voltage (in a range of 2). The modulation transfer functions of the two systems have the same trend. The performance of the Konica Regius 336 is nearly equivalent to that of an analogic system. The main advantages of the digital system are a standard output, lower consumption of radiographic films, higher productiveness and better image quality standard level [it

  10. Short TI inversion-recovery MR imaging of chest wall malignancies

    International Nuclear Information System (INIS)

    Dubinsky, T.J.; Porter, B.A.; Olson, D.O.

    1987-01-01

    Short-T1 inversion-recovery (STIR) sequences have greater constant, less motion sensitivity, and require shorter imaging times than conventional T2-weighted spin-echo (SE) sequences and are therefore particularly useful for staging chest wall malignancies. MR studies of 49 patients with possible chest wall malignancies were reviewed. Images were produced at 0.15 T with a variety of SE sequences. Forty-five also had STIR (repetition time, 1,400 - 2,100; echo time, 36 or 40; inversion time, 100 or 125). MR studies indicated chest wall involvement in 39 of 49 patients; 12 had obvious rib encasement, the most definitive finding. IN 13, lesions detected on STIR were either not visible or seen only in retrospect on T1 SE images. In five of five, STIR was clearly superior to T2 SE for delineation of tumor margins. The authors have discontinued using T2 SE sequences for chest neoplasms in favor of the higher contrast and sensitivity of STIR

  11. Nodule detection in digital chest radiography: Part of image background acting as pure noise

    International Nuclear Information System (INIS)

    Baath, M.; Haakansson, M.; Boerjesson, S.; Kheddache, S.; Grahn, A.; Bochud, F. O.; Verdun, F. R.; Maansson, L. G.

    2005-01-01

    There are several factors that influence the radiologist's ability to detect a specific structure/lesion in a radiograph. Three factors that are commonly known to be of major importance are the signal itself, the system noise and the projected anatomy. The aim of this study was to determine to what extent the image background acts as pure noise for the detection of subtle lung nodules in five different regions of the chest. A receiver operating characteristic (ROC) study with five observers was conducted on two different sets of images, clinical chest X-ray images and images with a similar power spectrum as the clinical images but with a random phase spectrum, resulting in an image background containing pure noise. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrasts were added to the images. As a measure of the part of the image background that acts as pure noise, the ratio between the contrast needed to obtain an area under the ROC curve of 0.80 in the clinical images to that in the random-phase images was used. The ratio ranged from 0.40 (in the lateral pulmonary regions) to 0.83 (in the hilar regions) indicating that there was a large difference between different regions regarding to what extent the image background acted as pure noise; and that in the hilar regions the image background almost completely acted as pure noise for the detection of 10 mm nodules. (authors)

  12. An investigation on comprehensive evaluation and standard of image quality of high voltage chest radiograph

    International Nuclear Information System (INIS)

    Yan Shulin; Li Shuopeng; Zhao Bo; Niu Yantao

    1998-01-01

    Purpose: Based on clinical diagnostic demand, patient irradiation dose and imaging technical parameters, to establish a comprehensive evaluation method and standard in chest radiograph. Methods: (1) From 10 normal chest radiographs, the authors selected the evaluation area on thoracic PA (posteroanterior) radiographs and set up standard for diagnostic demand; (2) Using chest CT scans of 20 males and 20 females, the authors calculated the ratio of lung field to mediastinum; (3) Selecting 100 chest films using 125 kVp, the authors measured the standard density values of each evaluation area; (4) Body surface irradiation doses of 478 normal adults were measured. Results: (1) Based on diagnostic demand, the authors confirmed 7 evaluation areas and 4 physical evaluation factors. At the same time, evaluation standards were obtained; (2) Comprehensive evaluation methods were established; (3) Standard height, weight and body surface irradiation dose of Chinese normal adults were investigated preliminarily. Conclusion: Based on the concept of comprehensive evaluation, investigation on the evaluation methods and standard in chest PA radiograph was carried out which might be taken as the foundation for future approach on nation-wide basis

  13. New developments in ultrasonic imaging of the chest and other body organs

    International Nuclear Information System (INIS)

    Campbell, G.W.; Anderson, A.L.

    1978-01-01

    The ultrasonic imaging system described herein was developed to measure chest-wall thickness and the percentage of fat in the chest and around other body organs. The system uses pulse-echo techniques to transmit and detect sound waves reflected from the interfaces of body organs and adjacent tissue. A computer draws these interfaces on color scans, and a code is used to exponentially average data from several points on each scan to find the average thicknesses of the chest wall and fat layers. These average thicknesses are then used to adjust x-ray calibration factors for plutonium lung counters. The correction factor for three subjects measured for fat content ranging from 12.6 to 22.2% was 18 to 41%. The ultrasonic system also defines the shape and position of the kidneys and liver so we are able to more accurately place detectors on the body during in-vivo radiation measurements. We have also developed a technique for displaying the interfaces from a series of ultrasonic chest scans to produce a topographical map that enables us to better understand the shape and contour of the lung and chest-wall interface

  14. Evaluation of the distortions of the digital chest image caused by the data compression

    International Nuclear Information System (INIS)

    Ando, Yutaka; Kunieda, Etsuo; Ogawa, Koichi; Tukamoto, Nobuhiro; Hashimoto, Shozo; Aoki, Makoto; Kurotani, Kenichi.

    1988-01-01

    The image data compression methods using orthogonal transforms (Discrete cosine transform, Discrete fourier transform, Hadamard transform, Haar transform, Slant transform) were analyzed. From the points of the error and the speed of the data conversion, the discrete cosine transform method (DCT) is superior to the other methods. The block quantization by the DCT for the digital chest image was used. The quality of data compressed and reconstructed images by the score analysis and the ROC curve analysis was examined. The chest image with the esophageal cancer and metastatic lung tumors was evaluated at the 17 checkpoints (the tumor, the vascular markings, the border of the heart and ribs, the mediastinal structures and et al). By our score analysis, the satisfactory ratio of the data compression is 1/5 and 1/10. The ROC analysis using normal chest images superimposed by the artificial coin lesions was made. The ROC curve of the 1/5 compressed ratio is almost as same as the original one. To summarize our study, the image data compression method using the DCT is thought to be useful for the clinical use and the 1/5 compression ratio is a tolerable ratio. (author)

  15. Dual-source computed tomography in patients with acute chest pain: feasibility and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schertler, Thomas; Scheffel, Hans; Frauenfelder, Thomas; Desbiolles, Lotus; Leschka, Sebastian; Stolzmann, Paul; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Department of Medical Radiology, Institute of Diagnostic Radiology, Zurich (Switzerland); Seifert, Burkhardt [University of Zurich, Department of Biostatistics, Zurich (Switzerland); Flohr, Thomas G. [Computed Tomography CTE PA, Siemens Medical Solutions, Forchheim (Germany)

    2007-12-15

    The aim of this study was to determine the feasibility and image quality of dual-source computed tomography angiography (DSCTA) in patients with acute chest pain for the assessment of the lung, thoracic aorta, and for pulmonary and coronary arteries. Sixty consecutive patients (32 female, 28 male, mean age 58.1{+-}16.3 years) with acute chest pain underwent contrast-enhanced electrocardiography-gated DSCTA without prior beta-blocker administration. Vessel attenuation of different thoracic vascular territories was measured, and image quality was semi-quantitatively analyzed by two independent readers. Image quality of the thoracic aorta was diagnostic in all 60 patients, image quality of pulmonary arteries was diagnostic in 59, and image quality of coronary arteries was diagnostic in 58 patients. Pairwise intraindividual comparisons of attenuation values were small and ranged between 1{+-}6 HU comparing right and left coronary artery and 56{+-}9 HU comparing the pulmonary trunk and left ventricle. Mean attenuation was 291{+-}65 HU in the ascending aorta, 334{+-}93 HU in the pulmonary trunk, and 285{+-}66 HU and 268{+-}67 HU in the right and left coronary artery, respectively. DSCTA is feasible and provides diagnostic image quality of the thoracic aorta, pulmonary and coronary arteries in patients with acute chest pain. (orig.)

  16. Dual-source computed tomography in patients with acute chest pain: feasibility and image quality

    International Nuclear Information System (INIS)

    Schertler, Thomas; Scheffel, Hans; Frauenfelder, Thomas; Desbiolles, Lotus; Leschka, Sebastian; Stolzmann, Paul; Marincek, Borut; Alkadhi, Hatem; Seifert, Burkhardt; Flohr, Thomas G.

    2007-01-01

    The aim of this study was to determine the feasibility and image quality of dual-source computed tomography angiography (DSCTA) in patients with acute chest pain for the assessment of the lung, thoracic aorta, and for pulmonary and coronary arteries. Sixty consecutive patients (32 female, 28 male, mean age 58.1±16.3 years) with acute chest pain underwent contrast-enhanced electrocardiography-gated DSCTA without prior beta-blocker administration. Vessel attenuation of different thoracic vascular territories was measured, and image quality was semi-quantitatively analyzed by two independent readers. Image quality of the thoracic aorta was diagnostic in all 60 patients, image quality of pulmonary arteries was diagnostic in 59, and image quality of coronary arteries was diagnostic in 58 patients. Pairwise intraindividual comparisons of attenuation values were small and ranged between 1±6 HU comparing right and left coronary artery and 56±9 HU comparing the pulmonary trunk and left ventricle. Mean attenuation was 291±65 HU in the ascending aorta, 334±93 HU in the pulmonary trunk, and 285±66 HU and 268±67 HU in the right and left coronary artery, respectively. DSCTA is feasible and provides diagnostic image quality of the thoracic aorta, pulmonary and coronary arteries in patients with acute chest pain. (orig.)

  17. Evaluation of the distortions of the digital chest image caused by the data compression

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Yutaka; Kunieda, Etsuo; Ogawa, Koichi; Tukamoto, Nobuhiro; Hashimoto, Shozo; Aoki, Makoto; Kurotani, Kenichi

    1988-08-01

    The image data compression methods using orthogonal transforms (Discrete cosine transform, Discrete fourier transform, Hadamard transform, Haar transform, Slant transform) were analyzed. From the points of the error and the speed of the data conversion, the discrete cosine transform method (DCT) is superior to the other methods. The block quantization by the DCT for the digital chest image was used. The quality of data compressed and reconstructed images by the score analysis and the ROC curve analysis was examined. The chest image with the esophageal cancer and metastatic lung tumors was evaluated at the 17 checkpoints (the tumor, the vascular markings, the border of the heart and ribs, the mediastinal structures and et al). By our score analysis, the satisfactory ratio of the data compression is 1/5 and 1/10. The ROC analysis using normal chest images superimposed by the artificial coin lesions was made. The ROC curve of the 1/5 compressed ratio is almost as same as the original one. To summarize our study, the image data compression method using the DCT is thought to be useful for the clinical use and the 1/5 compression ratio is a tolerable ratio.

  18. Intelligent retrieval of chest X-ray image database using sketches

    International Nuclear Information System (INIS)

    Hasegawa, Jun-ichi; Okada, Noritake; Toriwaki, Jun-ichiro

    1988-01-01

    This paper presents further experiments on intelligent retrieval in our chest X-ray image database system using 'sketches'. First, in the previous sketch extraction procedure, vertical-location-invariant thresholding and shape-oriented smoothing are newly developed to improve the precision of lung borders and rib images in each sketch, respectively. Then, two new ways for image retrieval using sketches; (1) image-description retrieval and (2) pattern-matching retrieval, are proposed. In each retrieval way, a procedure for understanding picture queries input through a sketch is described in detail. (author)

  19. Chest imaging with dual-energy substraction digital tomosynthesis

    International Nuclear Information System (INIS)

    Sone, S.; Kasuga, T.; Sakai, F.; Hirano, H.; Kubo, K.; Morimoto, M.; Takemura, K.; Hosoba, M.

    1993-01-01

    Dual-energy subtraction digital tomosynthesis with pulsed X-ray and rapid kV switching was used to examine calcifications in pulmonary lesions. The digital tomosynthesis system used included a conventional fluororadiographic TV unit with linear tomographic capabilities, a high resolution videocamera, and an image processing unit. Low-voltage, high voltage, and soft tissue subtracted or bone subtracted tomograms of any desired layer height were reconstructed from the image data acquired during a single tomographic swing. Calcifications, as well as their characteristics and distribution in pulmonary lesions, were clearly shown. The images also permitted discrimination of calcifications from dense fibrotic lesions. This technique was effective in demonstrating calcifications together with a solitary mass or disseminated nodules. (orig.)

  20. Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies; Resultados discordantes em cintilografias das paratireoides realizadas com tetrofosmin-99mTc e com sestamibi-99mTc

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Paulo Schiavom; Domingues, Fernanda C.; Santi Costa, Michele; Brandao, Cynthia; Oliveira, Marco A.C. de; Vieira, Jose G.H. [Fleury - Centro de Medicina Diagnostica, Sao Paulo, SP (Brazil)]. E-mail: paulo.duarte@fleury.com.br

    2007-10-15

    Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods. (author)

  1. Computed radiography versus mobile direct radiography for bedside chest radiographs: impact of dose on image quality and reader agreement

    NARCIS (Netherlands)

    de Boo, D. W.; Weber, M.; Deurloo, E. E.; Streekstra, G. J.; Freling, N. J.; Dongelmans, D. A.; Schaefer-Prokop, C. M.

    2011-01-01

    To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Three groups of age-, weight- and disease-matched ICU patients (n=114 patients; 50 CXR per

  2. Two K versus 4 K storage phosphor chest radiography: detection performance and image quality

    International Nuclear Information System (INIS)

    Koelblinger, Claus; Weber, Michael; Sailer, Johannes; Cartes-Zumelzu, Fabiola; Prokop, Mathias; Schaefer-Prokop, Cornelia

    2007-01-01

    The purpose of this study was to evaluate the effect of matrix size (4-K versus 2-K) in digital storage phosphor chest radiographs on image quality and on the detection of CT-proven thoracic abnormalities. In 85 patients who underwent a CT of the thorax, we obtained two additional posteroanterior storage phosphor chest radiographs, one with a matrix size of 3,520 x 4,280 (=4-K) and the other with a matrix size of 1,760 x 2,140 (=2-K). Acquisition, processing and presentation parameters were identical for all radiographs. Two radiologists evaluated the presence of mediastinal, pleural, and pulmonary abnormalities on hard copies of the radiographs, applying ROC analysis. In addition, four radiologists were asked to subjectively rank differences in image quality and to assess the demarcation of anatomic landmarks comparing the images in a blinded side-by-side manner. These data were analyzed using a two-sided binomial test with a significance level of P<0.05. Both tests, the ROC analysis of the detection performance and the binomial test of the subjective quality ratings, did not reveal significant differences between the two matrix sizes. Compared to 2-K radiographs, 4-K storage phosphor chest radiographs do not provide superior detection performance or image quality when evaluated in identical hard copy formats. (orig.)

  3. Use of morphologic filters in the computerized detection of lung nodules in digital chest images

    International Nuclear Information System (INIS)

    Yoshimura, H.; Giger, M.L.; Doi, K.; Ahn, N.; MacMahon, H.

    1989-01-01

    The authors have previously described a computerized scheme for the detection of lung nodules based on a difference-image approach, which had a detection accuracy of 70% with 7--8 false positives per image. Currently, they are investigating morphologic filters for the further enhancement/suppression of nodule-signals and the removal of false-positives. Gray-level morphologic filtering is performed on clinical chest radiographs digitized with an optical drum scanner. Various shapes and sequences of erosion and dilation filters (i.e., determination of the minimum and maximum gray levels, respectively) were examined for signal enhancement and suppression for sue in the difference- image approach

  4. The methods for detecting multiple small nodules from 3D chest X-ray CT images

    International Nuclear Information System (INIS)

    Hayase, Yosuke; Mekada, Yoshito; Mori, Kensaku; Toriwaki, Jun-ichiro; Natori, Hiroshi

    2004-01-01

    This paper describes a method for detecting small nodules, whose CT values and diameters are more than -600 Hounsfield unit (H.U.) and 2 mm, from three-dimensional chest X-ray CT images. The proposed method roughly consists of two submodules: initial detection of nodule candidates by discriminating between nodule regions and other regions such as blood vessels or bronchi using a shape feature computed from distance values inside the regions and reduction of false positive (FP) regions by using a minimum directional difference filter called minimum directional difference filter (Min-DD) changing its radius suit to the size of the initial candidates. The performance of the proposed method was evaluated by using seven cases of chest X-ray CT images including six abnormal cases where multiple lung cancers are observed. The experimental results for nodules (361 regions in total) showed that sensitivity and FP regions are 71% and 7.4 regions in average per case. (author)

  5. The role of imaging for the surgeon in primary malignant bone tumors of the chest wall

    Energy Technology Data Exchange (ETDEWEB)

    Rocca, M., E-mail: michele.rocca@ior.it [General and Thoracic Surgery, The Rizzoli Orthopaedic Institute, Via Pupilli 1, 40136 Bologna (Italy); Salone, M. [General and Thoracic Surgery, The Rizzoli Orthopaedic Institute, Via Pupilli 1, 40136 Bologna (Italy); Galletti, S. [Ultrasound Unit, The Rizzoli Orthopaedic Institute, Bologna (Italy); Balladelli, A. [Laboratory of Experimental Oncology, The Rizzoli Orthopaedic Institute, Bologna (Italy); Vanel, D. [Research in Imaging Musculo Skeletal Tumors, The Rizzoli Orthopaedic Institute, Bologna (Italy); Briccoli, A. [General and Thoracic Surgery, The Rizzoli Orthopaedic Institute, Via Pupilli 1, 40136 Bologna (Italy)

    2013-12-01

    Primary malignant chest wall tumors are rare. The most frequent primary malignant tumor of the chest wall is chondrosarcoma, less common are primary bone tumors belonging to the Ewing Family Bone Tumors (EFBT), or even rarer are osteosarcomas. They represent a challenging clinical entities for surgeons as the treatment of choice for these neoplasms is surgical resection, excluding EFBT which are normally treated by a multidisciplinary approach. Positive margins after surgical procedure are the principal risk factor of local recurrence, therefore to perform adequate surgery a correct preoperative staging is mandatory. Imaging techniques are used for diagnosis, to determine anatomic site and extension, to perform a guided biopsy, for local and general staging, to evaluate chemotherapy response, to detect the presence of a recurrence. This article will focus on the role of imaging in guiding this often difficult surgery and the different technical possibilities adopted in our department to restore the mechanics of the thoracic cage after wide resections.

  6. Muscular sarcoidosis involving the chest and abdominal walls: case report with MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seunghyun; Lee, In Sook; Song, You Seon [Pusan National University Hospital, Biomedical Research Institute, Department of Radiology, Busan (Korea, Republic of); Pusan National University School of Medicine, Busan (Korea, Republic of); Mok, Jeongha [Pusan National University Hospital, Biomedical Research Institute, Department of Internal Medicine, Busan (Korea, Republic of); Choi, Kyung-Un [Pusan National University Hospital, Biomedical Research Institute, Department of Pathology, Busan (Korea, Republic of)

    2018-03-15

    Sarcoidosis is an inflammatory disorder that is characterized by the presence of noncaseating granulomas in tissues, involving many organs and tissues. Extra-pulmonary, especially muscular sarcoidosis is a rare condition. The most common location of the muscular sarcoidosis is known to be the proximal muscles of the extremities; however, there have been no cases of diffuse involvement of the chest and abdominal wall muscles. Here, we report a rare muscular sarcoidosis with infiltrative pattern in the chest and abdominal wall muscles and describe the MR imaging findings that were mistaken as lymphoma at initial diagnosis. Although our case did not show characteristic MR findings of muscular sarcoidosis, clinicians or radiologists who are aware of these imaging features can perform early systemic survey for sarcoidosis. Also muscle biopsy is very important to confirm the sarcoidosis and distinguish it from other tumors. (orig.)

  7. Muscular sarcoidosis involving the chest and abdominal walls: case report with MR imaging

    International Nuclear Information System (INIS)

    Lee, Seunghyun; Lee, In Sook; Song, You Seon; Mok, Jeongha; Choi, Kyung-Un

    2018-01-01

    Sarcoidosis is an inflammatory disorder that is characterized by the presence of noncaseating granulomas in tissues, involving many organs and tissues. Extra-pulmonary, especially muscular sarcoidosis is a rare condition. The most common location of the muscular sarcoidosis is known to be the proximal muscles of the extremities; however, there have been no cases of diffuse involvement of the chest and abdominal wall muscles. Here, we report a rare muscular sarcoidosis with infiltrative pattern in the chest and abdominal wall muscles and describe the MR imaging findings that were mistaken as lymphoma at initial diagnosis. Although our case did not show characteristic MR findings of muscular sarcoidosis, clinicians or radiologists who are aware of these imaging features can perform early systemic survey for sarcoidosis. Also muscle biopsy is very important to confirm the sarcoidosis and distinguish it from other tumors. (orig.)

  8. Differential diagnosis of MRI detected intra cranial space occupying lesions (ICSOLS)-role of 99MTC tetrofosmin cerebral spect

    International Nuclear Information System (INIS)

    Padmal, S.; Sundaram, P.S.; Kumar, S.

    2004-01-01

    Discriminating the correct etiology of Intra Cranial Space Occupying Lesions (ICSOLs) detected by MRI is of paramount importance in deciding the right therapeutic approach. Functional imaging like 99m Tc Tetrofosmin cerebral SPECT (C SPECT) can be used to differentiate malignant from other benign cerebral pathologies. Objective: Our aim was to assess the efficacy of C SPECT in differentiating various etiologies (i.e. Infective / Inflammatory, Neoplastic and Post Radiotherapy changes) of MRI detected ICSOLs. We also aimed to assess the incremental value of quantitative uptake ratios in identifying the exact nature of ICSOLs. Method: 26 Patients (M:F=20:6), age range 28-76 yrs, mean 42±7 yrs were evaluated by 99mTc Tetrofosmin cerebral SPECT. 14/26 patients were HIV positive cases while remaining 12 were treated patients of intracerebral malignancies. All these patients had one or more discrete MRI detected ICSOLs. 6/4 patients with HIV and 4/12 patients in the non HIV group showed more than 1 discrete ICSOLs. 20 mci of 99mTc Tetrofosmin was injected IV .15 min (early) and 2 hrs (delayed) post injection C SPECT images were acquired on a dual head variable angle Gamma camera. After reconstruction, transverse, coronal and sagittal images were co- registered with DICOM online available MRI images using aco- registration software. Focal Tetrofosmin uptake in MRI detected ICSOL was interpreted as abnormal. Tetrofosmin uptake index (Ix) was calculated in early and delayed images as ratio of counts in lesion to that of contra lateral region. A value of more than 1.3 was considered to be abnormal. Persistent Ix of more than 1.3 in initial and delayed images were considered to be malignant while Ix of more or less than 1.3 in initial but less than 1.3 in delayed images was considered to be benign in both groups. Results: In HIV group (14 pts), 4 patients showed an Ix of less than 1.3 in both early and delayed images and 7 patients showed an Ix of more than 1.3 in early but

  9. Bone images from dual-energy subtraction chest radiography in the detection of rib fractures

    Energy Technology Data Exchange (ETDEWEB)

    Szucs-Farkas, Zsolt, E-mail: zsolt.szuecs@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Lautenschlager, Katrin, E-mail: katrin@students.unibe.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Flach, Patricia M., E-mail: patricia.flach@irm.unibe.ch [Institute of Forensic Medicine, University of Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Ott, Daniel, E-mail: daniel.ott@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Strautz, Tamara, E-mail: tamara.strautz@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Vock, Peter, E-mail: peter.vock@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Ruder, Thomas D., E-mail: thomas.ruder@irm.unibe.ch [Institute of Forensic Medicine, University of Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland)

    2011-08-15

    Objective: To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures. Materials and methods: In this retrospective study, 39 patients with 204 rib fractures and 24 subjects with no fractures were examined with a single exposure dual-energy subtraction digital radiography system. Three blinded readers first evaluated the non-subtracted posteroanterior and lateral chest radiographs alone, and 3 months later they evaluated the non-subtracted images together with the subtracted posteroanterior bone images. The locations of rib fractures were registered with confidence levels on a 3-grade scale. Image quality was rated on a 5-point scale. Marks by readers were compared with fracture localizations in CT as a standard of reference. Results: The sensivity for fracture detection using both methods was very similar (34.3% with standard CXR and 33.5% with ES-CXR, p = 0.92). At the patient level, both sensitivity (71.8%) and specificity (92.9%) with or without ES were identical. Diagnostic confidence was not significantly different (2.61 with CXR and 2.75 with ES-CXR, p = 0.063). Image quality with ES was rated higher than that on standard CXR (4.08 vs. 3.74, p < 0.001). Conclusions: Despite a better image quality, adding ES bone images to standard radiographs of the chest does not provide better sensitivity or improved diagnostic confidence in the detection of rib fractures.

  10. Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lanzman, Rotem S.; Blondin, Dirk; Furst, Gunter; Scherer, Axel; R Miese, Falk; Kroepil, Patric [University of Duesseldorf, Medical Faculty, 40225 Duesseldorf (Germany); Winter, Joachim [University Hospital Duesseldorf, 40225 Duesseldorf (Germany); Abbara, Suhny [Massachusetts General Hospital, Boston, MA (US)

    2011-10-15

    Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this study. Additionally, the imaging features of incorrect lead positions and defects, as well as complications subsequent to pacemaker implantation are demonstrated herein.

  11. Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT

    International Nuclear Information System (INIS)

    Lanzman, Rotem S.; Blondin, Dirk; Furst, Gunter; Scherer, Axel; R Miese, Falk; Kroepil, Patric; Winter, Joachim; Abbara, Suhny

    2011-01-01

    Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this study. Additionally, the imaging features of incorrect lead positions and defects, as well as complications subsequent to pacemaker implantation are demonstrated herein.

  12. Incremental value of combined 99MTc tetrofosmin parathyroid scintigraphy, rapid intra operative PTH assays and minimally invasive radio-guided surgery (MIRS) in optimizing parathyroidectomies

    International Nuclear Information System (INIS)

    Padma, S.; Kumar, S.; Babu, T.; Kumar, H.; Nair, V.; Nair, G.K.

    2004-01-01

    Objective: Aim of our study was to evaluate incremental diagnostic value of 99mTc Tetrofosmin parathyroid SPECT (TPSPECT), rapid intra operative quick parathyroid hormone measurement (QPTH) combined with radio guidance provided by scintillation probe (Minimally Invasive Radio guided Surgery MIRS) in parathyroid surgeries. While TPSPECT is an established investigation in preoperative workup of hyperparathyroidism patients , MIRS is a relatively new concept in Indian subcontinent. Methods: 29 pts (M: F = 18: 11), age range 16- 65 yrs (mean 41+ 9 yrs) having clinical and biochemical hyperparathyroidism underwent TPSPECT between Jan 02 -04, using 20 mci IV 99mTc Tetrofosmin. Pts with familial hyperparathyroidism , previous nodular goiters and previous neck irradiation were excluded from study. Scintigraphy comprised of immediate, delayed planar and SPECT imaging of neck and chest. Imagewise abnormal, persistent tracer uptake was considered positive for adenoma and diffuse uptake for hyperplasia. 26 pts underwent exploration (22 adenomas and 4 hyperplasias).18 pts had benefit of intraoperative QPTH. A select group (after Dec 2003) i.e. 9 pts got the assistance of radioguided probing. Peroperatively NM physician used cordless handheld gamma probe (Gamma Finder, World of Medicine, Germany) in neck and mediastinum to detect parathyroid adenoma / hyperplasias. A five fold increase in radioactive counts perceived by probe when compared to background was considered positive for parathyroid adenoma / hyperplasia. If PTH levels fell from baseline by at least 50%, the surgery was concluded as complete. Results: In all 22 pts suspected to have primary hyperparathyroidism TPSPECT identified adenomas (100 % sensitivity). While planar imaging had a sensitivity of 90.1% (20/22 pts), SPECT identified the adenoma in all pts. Interestingly only 3/22 pts had ectopic glands while 5 had more than one adenomas. The most commonly involved gland was left inferior. In secondary

  13. Phantom development for radiographic image optimization of chest, skull and pelvis examination for nonstandard patient

    International Nuclear Information System (INIS)

    Pina, D.R.; Duarte, S.B.; Ghilardi Netto, T.; Morceli, J.

    2009-01-01

    The construction of the adapted patient equivalent phantom (APEP) to simulate the X-ray scattering and absorption by chest, skull and pelvis of nonstandard patient in conventional radiographic equipment is presented. This APEP system is associated to the pre-existing realistic-analytic phantom (RAP) [Pina, D.R., Duarte, S.B., Ghilardi Netto, T., Trad, C. S., Brochi, M.A.C., Oliveira, S.C. de, 2004. Optimization of standard patient radiographic images for chest, skull and pelvis exams in conventional X-ray equipment. Phys. Med. Biol. 49, N215-N226] forming the coupled phantom (RAP-APEP), which is used to establish an optimization process of radiographic images of chest, skull and pelvis for nonstandard patients. A chart of the optimized radiographic technique is established covering a wide range of nonstandard patient thickness, and offering a dose reduction in comparison with those techniques currently used. Different validation processes were applied to confirm the improving of the radiographic image quality when techniques of the established chart are used

  14. Magnetic resonance imaging of the chest: current and new applications, with an emphasis on pulmonology

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcel Koenigkam; Mauad, Fernando Marum, E-mail: marcelk46@yahoo.com.b [Universidade de Sao Paulo (HC/FMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Elias Junior, Jorge; Muglia, Valdair Francisco [Universidade de Sao Paulo (FMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Secao de Radiologia

    2011-03-15

    The objective of the present review study was to present the principal applications of magnetic resonance imaging (MRI) of the chest, including the description of new techniques. Over the past decade, this method has evolved considerably because of the development of new equipment, including the simultaneous interconnection of phased-array multiple radiofrequency receiver coils and remote control of the table movement, in addition to faster techniques of image acquisition, such as parallel imaging and partial Fourier acquisitions, as well as the introduction of new contrast agents. All of these advances have allowed MRI to gain ground in the study of various pathologies of the chest, including lung diseases. Currently, MRI is considered the modality of choice for the evaluation of lesions in the mediastinum and in the chest wall, as well as of superior sulcus tumors. However, it can also facilitate the diagnosis of lung, pleural, and cardiac diseases, as well as of those related to the pulmonary vasculature. Pulmonary MRI angiography can be used in order to evaluate various pulmonary vascular diseases, and it has played an ever greater role in the study of thromboembolism. Because cardiac MRI allows morphological and functional assessment in the same test, it has also become part of the clinical routine in the evaluation of various cardiac diseases. Finally, the role of MRI has been extended to the identification and characterization of pulmonary nodules, the evaluation of airway diseases, and the characterization of pleural effusion. (author)

  15. Imaging of implants on chest radiographs: a radiological perspective

    International Nuclear Information System (INIS)

    Burney, K.; Thayur, N.; Husain, S.A.; Martin, R.P.; Wilde, P.

    2007-01-01

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant

  16. Imaging of implants on chest radiographs: a radiological perspective

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Thayur, N [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Husain, S A [Department of Respiratory Medicine, Bristol Royal Infirmary (United Kingdom); Martin, R P [Department of Cardiology, Bristol Royal Hospital for Children, Bristol (United Kingdom); Wilde, P [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom)

    2007-03-15

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant.

  17. Design and Development of a New Multi-Projection X-Ray System for Chest Imaging

    Science.gov (United States)

    Chawla, Amarpreet S.; Boyce, Sarah; Washington, Lacey; McAdams, H. Page; Samei, Ehsan

    2009-02-01

    Overlapping anatomical structures may confound the detection of abnormal pathology, including lung nodules, in conventional single-projection chest radiography. To minimize this fundamental limiting factor, a dedicated digital multi-projection system for chest imaging was recently developed at the Radiology Department of Duke University. We are reporting the design of the multi-projection imaging system and its initial performance in an ongoing clinical trial. The system is capable of acquiring multiple full-field projections of the same patient along both the horizontal and vertical axes at variable speeds and acquisition frame rates. These images acquired in rapid succession from slightly different angles about the posterior-anterior (PA) orientation can be correlated to minimize the influence of overlying anatomy. The developed system has been tested for repeatability and motion blur artifacts to investigate its robustness for clinical trials. Excellent geometrical consistency was found in the tube motion, with positional errors for clinical settings within 1%. The effect of tube-motion on the image quality measured in terms of impact on the modulation transfer function (MTF) was found to be minimal. The system was deemed clinic-ready and a clinical trial was subsequently launched. The flexibility of image acquisition built into the system provides a unique opportunity to easily modify it for different clinical applications, including tomosynthesis, correlation imaging (CI), and stereoscopic imaging.

  18. Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan

    International Nuclear Information System (INIS)

    Kim, Hyun Ju; Cho, Jae Hwan; Park, Cheol Soo

    2010-01-01

    The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). CT value of chest image increased at 100 kVp by 14.06%∼27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  20. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  1. Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Franziska M.; Johnson, Thorsten R.C.; Sommer, Wieland H.; Thierfelder, Kolja M.; Meinel, Felix G. [University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-06-01

    To determine the radiation dose, image quality, and clinical utility of non-enhanced chest CT with spectral filtration. We retrospectively analysed 25 non-contrast chest CT examinations acquired with spectral filtration (tin-filtered Sn100 kVp spectrum) compared to 25 examinations acquired without spectral filtration (120 kV). Radiation metrics were compared. Image noise was measured. Contrast-to-noise-ratio (CNR) and figure-of-merit (FOM) were calculated. Diagnostic confidence for the assessment of various thoracic pathologies was rated by two independent readers. Effective chest diameters were comparable between groups (P = 0.613). In spectral filtration CT, median CTDI{sub vol}, DLP, and size-specific dose estimate (SSDE) were reduced (0.46 vs. 4.3 mGy, 16 vs. 141 mGy*cm, and 0.65 vs. 5.9 mGy, all P < 0.001). Spectral filtration CT had higher image noise (21.3 vs. 13.2 HU, P < 0.001) and lower CNR (47.2 vs. 75.3, P < 0.001), but was more dose-efficient (FOM 10,659 vs. 2,231/mSv, P < 0.001). Diagnostic confidence for parenchymal lung disease and osseous pathologies was lower with spectral filtration CT, but no significant difference was found for pleural pathologies, pulmonary nodules, or pneumonia. Non-contrast chest CT using spectral filtration appears to be sufficient for the assessment of a considerable spectrum of thoracic pathologies, while providing superior dose efficiency, allowing for substantial radiation dose reduction. (orig.)

  2. Bone images from dual-energy subtraction chest radiography in the detection of rib fractures.

    Science.gov (United States)

    Szucs-Farkas, Zsolt; Lautenschlager, Katrin; Flach, Patricia M; Ott, Daniel; Strautz, Tamara; Vock, Peter; Ruder, Thomas D

    2011-08-01

    To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures. In this retrospective study, 39 patients with 204 rib fractures and 24 subjects with no fractures were examined with a single exposure dual-energy subtraction digital radiography system. Three blinded readers first evaluated the non-subtracted posteroanterior and lateral chest radiographs alone, and 3 months later they evaluated the non-subtracted images together with the subtracted posteroanterior bone images. The locations of rib fractures were registered with confidence levels on a 3-grade scale. Image quality was rated on a 5-point scale. Marks by readers were compared with fracture localizations in CT as a standard of reference. The sensivity for fracture detection using both methods was very similar (34.3% with standard CXR and 33.5% with ES-CXR, p=0.92). At the patient level, both sensitivity (71.8%) and specificity (92.9%) with or without ES were identical. Diagnostic confidence was not significantly different (2.61 with CXR and 2.75 with ES-CXR, p=0.063). Image quality with ES was rated higher than that on standard CXR (4.08 vs. 3.74, prib fractures. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Evaluation of pneumonia in children: comparison of MRI with fast imaging sequences at 1.5T with chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Yikilmaz, Ali; Koc, Ali; Coskun, Abdulhakim (Dept. of Radiology, Erciyes Medical School, Kayseri (Turkey)); Ozturk, Mustafa K (Dept. of Pediatric Infectious Diseases, Erciyes Medical School, Kayseri (Turkey)); Mulkern, Robert V; Lee, Edward Y (Dept. of Radiology and Dept. of Medicine, Pulmonary Div., Children' s Hospital Boston and Harvard Medical School, Boston (United States)), email: Edward.lee@childrens.harvard.edu

    2011-10-15

    Background Although there has been a study aimed at magnetic resonance imaging (MRI) evaluation of pneumonia in children at a low magnetic field (0.2T), there is no study which assessed the efficacy of MRI, particularly with fast imaging sequences at 1.5T, for evaluating pneumonia in children. Purpose To investigate the efficacy of chest MRI with fast imaging sequences at 1.5T for evaluating pneumonia in children by comparing MRI findings with those of chest radiographs. Material and Methods This was an Institutional Review Board-approved, HIPPA-compliant prospective study of 40 consecutive pediatric patients (24 boys, 16 girls; mean age 7.3 years +- 6.6 years) with pneumonia, who underwent PA and lateral chest radiographs followed by MRI within 24 h. All MRI studies were obtained in axial and coronal planes with two different fast imaging sequences: T1-weighted FFE (Fast Field Echo) (TR/TE: 83/4.6) and T2-weighted B-FFE M2D (Balanced Fast Field Echo Multiple 2D Dimensional) (TR/TE: 3.2/1.6). Two experienced pediatric radiologists reviewed each chest radiograph and MRI for the presence of consolidation, necrosis/abscess, bronchiectasis, and pleural effusion. Chest radiograph and MRI findings were compared with Kappa statistics. Results All consolidation, lung necrosis/abscess, bronchiectasis, and pleural effusion detected with chest radiographs were also detected with MRI. There was statistically substantial agreement between chest radiographs and MRI in detecting consolidation (k = 0.78) and bronchiectasis (k = 0.72) in children with pneumonia. The agreement between chest radiographs and MRI was moderate for detecting necrosis/abscess (k = 0.49) and fair for detecting pleural effusion (k = 0.30). Conclusion MRI with fast imaging sequences is comparable to chest radiographs for evaluating underlying pulmonary consolidation, bronchiectasis, necrosis/abscess, and pleural effusion often associated with pneumonia in children

  4. Evaluation of image quality when using grid during child chest x-ray examination

    Energy Technology Data Exchange (ETDEWEB)

    Jeung Seung Hun [Dept. of Radiology, SeoSan JungAng General Hospital, Seosan (Korea, Republic of); Han, Beom Hul [Dept. of Radiological Science, SeoNam University, Gwangju (Korea, Republic of); Jung, Hong Ryang [Dept. of Radiological Science, Hanseo University, (Korea, Republic of)

    2017-09-15

    Since in case of children, they are sensitive to the radiation compared to the adult and the potential exposure damage lasts longer, the exposure dose should be managed better than for the adult. Therefore, this study was conducted to observe the change in the chest x-ray image by the use of grid, which eliminates the scattering rays but increases the exposure dose during the child chest x-ray examination. As a research method, SNR, CNR and V. Vuichi were measured at 100 cm and 180 cm with the grid varying the kVp to 70, 90 and 110. In addition, SNR, CNR and V. Vuichi were measured fixing 100 cm and 180cm without grid and varying the dose to 6, 8 and 10 mAs. In the results of measuring them by fixing kVp, SNR, VNR and V. Vuichi were represented high when FID is 100cm. And in the results of meaduring them varying mAs, SNR, VNR and V. Vuichi were represented high when FID is 100cm. Currently in our country, the chest x-ray examination is performed at 180 cm. However, as the image is measured high when FID is 100 cm, in case of child, FID is deemed to be 100 cm.

  5. Evaluation of image quality when using grid during child chest x-ray examination

    International Nuclear Information System (INIS)

    Jeung Seung Hun; Han, Beom Hul; Jung, Hong Ryang

    2017-01-01

    Since in case of children, they are sensitive to the radiation compared to the adult and the potential exposure damage lasts longer, the exposure dose should be managed better than for the adult. Therefore, this study was conducted to observe the change in the chest x-ray image by the use of grid, which eliminates the scattering rays but increases the exposure dose during the child chest x-ray examination. As a research method, SNR, CNR and V. Vuichi were measured at 100 cm and 180 cm with the grid varying the kVp to 70, 90 and 110. In addition, SNR, CNR and V. Vuichi were measured fixing 100 cm and 180cm without grid and varying the dose to 6, 8 and 10 mAs. In the results of measuring them by fixing kVp, SNR, VNR and V. Vuichi were represented high when FID is 100cm. And in the results of meaduring them varying mAs, SNR, VNR and V. Vuichi were represented high when FID is 100cm. Currently in our country, the chest x-ray examination is performed at 180 cm. However, as the image is measured high when FID is 100 cm, in case of child, FID is deemed to be 100 cm

  6. Quantitative exercise technetium-99m tetrofosmin myocardial tomography for the identification and localization of coronary artery disease

    International Nuclear Information System (INIS)

    Sullo, P.; Cuocolo, A.; Nicolai, E.; Cardei, S.; Nappi, A.; Squame, F.; Covelli, E.M.; Pace, L.; Salvatore, M.

    1996-01-01

    The aim of this study was to evaluate the accuracy of quantitative 1-day exercise-rest technetium-99m tetrofosmin tomography in the identification of patients with coronary artery disease (CAD) and in the detection of individual stenosed coronary vessels. Sixty-one patients with suspected CAD who underwent coronary angiography and 13 normal volunteers were studied. All patients were submitted to two i.v. injections of 99m Tc-tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 h after exercise (images 15-30 min after injection for both studies). All patients with CAD (≥50% luminal stenosis) (n=50) had an abnormal 99m Tc-tetrofosmin tomogram. Only one patient without significant coronary narrowing showed abnormal findings. Overall senstivity, specificity and diagnostic accuracy in the detection of individual stenosed vissels were 77%, 93% and 85%, respectively. Sensitivity and diagnostic accuracy in the identification of individuals stenosed coronary vessels were significantly higher (P 75%). (orig.)

  7. Fifty years of computer analysis in chest imaging: rule-based, machine learning, deep learning.

    Science.gov (United States)

    van Ginneken, Bram

    2017-03-01

    Half a century ago, the term "computer-aided diagnosis" (CAD) was introduced in the scientific literature. Pulmonary imaging, with chest radiography and computed tomography, has always been one of the focus areas in this field. In this study, I describe how machine learning became the dominant technology for tackling CAD in the lungs, generally producing better results than do classical rule-based approaches, and how the field is now rapidly changing: in the last few years, we have seen how even better results can be obtained with deep learning. The key differences among rule-based processing, machine learning, and deep learning are summarized and illustrated for various applications of CAD in the chest.

  8. Correlation of contrast-detail analysis and clinical image quality assessment in chest radiography with a human cadaver study.

    Science.gov (United States)

    De Crop, An; Bacher, Klaus; Van Hoof, Tom; Smeets, Peter V; Smet, Barbara S; Vergauwen, Merel; Kiendys, Urszula; Duyck, Philippe; Verstraete, Koenraad; D'Herde, Katharina; Thierens, Hubert

    2012-01-01

    To determine the correlation between the clinical and physical image quality of chest images by using cadavers embalmed with the Thiel technique and a contrast-detail phantom. The use of human cadavers fulfilled the requirements of the institutional ethics committee. Clinical image quality was assessed by using three human cadavers embalmed with the Thiel technique, which results in excellent preservation of the flexibility and plasticity of organs and tissues. As a result, lungs can be inflated during image acquisition to simulate the pulmonary anatomy seen on a chest radiograph. Both contrast-detail phantom images and chest images of the Thiel-embalmed bodies were acquired with an amorphous silicon flat-panel detector. Tube voltage (70, 81, 90, 100, 113, 125 kVp), copper filtration (0.1, 0.2, 0.3 mm Cu), and exposure settings (200, 280, 400, 560, 800 speed class) were altered to simulate different quality levels. Four experienced radiologists assessed the image quality by using a visual grading analysis (VGA) technique based on European Quality Criteria for Chest Radiology. The phantom images were scored manually and automatically with use of dedicated software, both resulting in an inverse image quality figure (IQF). Spearman rank correlations between inverse IQFs and VGA scores were calculated. A statistically significant correlation (r = 0.80, P chest radiography. © RSNA, 2011.

  9. Automated computerized scheme for distinction between benign and malignant solitary pulmonary nodules on chest images

    International Nuclear Information System (INIS)

    Aoyama, Masahito; Li Qiang; Katsuragawa, Shigehiko; MacMahon, Heber; Doi, Kunio

    2002-01-01

    A novel automated computerized scheme has been developed to assist radiologists for their distinction between benign and malignant solitary pulmonary nodules on chest images. Our database consisted of 55 chest radiographs (33 primary lung cancers and 22 benign nodules). In this method, the location of a nodule was indicated first by a radiologist. The difference image with a nodule was produced by use of filters and then represented in a polar coordinate system. The nodule was segmented automatically by analysis of contour lines of the gray-level distribution based on the polar-coordinate representation. Two clinical parameters (age and sex) and 75 image features were determined from the outline, the image, and histogram analysis for inside and outside regions of the segmented nodule. Linear discriminant analysis (LDA) and knowledge about benign and malignant nodules were used to select initial feature combinations. Many combinations for subgroups of 77 features were evaluated as input to artificial neural networks (ANNs). The performance of ANNs with the selected 7 features by use of the round-robin test showed Az=0.872, which was greater than Az=0.854 obtained previously with the manual method (P=0.53). The performance of LDA (Az=0.886) was slightly improved compared to that of ANNs (P=0.59) and was greater than that of the manual method (Az=0.854) reported previously (P=0.40). The high level of its performance indicates the potential usefulness of this automated computerized scheme in assisting radiologists as a second opinion for distinction between benign and malignant solitary pulmonary nodules on chest images

  10. Evaluation of automatic image quality assessment in chest CT - A human cadaver study.

    Science.gov (United States)

    Franck, Caro; De Crop, An; De Roo, Bieke; Smeets, Peter; Vergauwen, Merel; Dewaele, Tom; Van Borsel, Mathias; Achten, Eric; Van Hoof, Tom; Bacher, Klaus

    2017-04-01

    The evaluation of clinical image quality (IQ) is important to optimize CT protocols and to keep patient doses as low as reasonably achievable. Considering the significant amount of effort needed for human observer studies, automatic IQ tools are a promising alternative. The purpose of this study was to evaluate automatic IQ assessment in chest CT using Thiel embalmed cadavers. Chest CT's of Thiel embalmed cadavers were acquired at different exposures. Clinical IQ was determined by performing a visual grading analysis. Physical-technical IQ (noise, contrast-to-noise and contrast-detail) was assessed in a Catphan phantom. Soft and sharp reconstructions were made with filtered back projection and two strengths of iterative reconstruction. In addition to the classical IQ metrics, an automatic algorithm was used to calculate image quality scores (IQs). To be able to compare datasets reconstructed with different kernels, the IQs values were normalized. Good correlations were found between IQs and the measured physical-technical image quality: noise (ρ=-1.00), contrast-to-noise (ρ=1.00) and contrast-detail (ρ=0.96). The correlation coefficients between IQs and the observed clinical image quality of soft and sharp reconstructions were 0.88 and 0.93, respectively. The automatic scoring algorithm is a promising tool for the evaluation of thoracic CT scans in daily clinical practice. It allows monitoring of the image quality of a chest protocol over time, without human intervention. Different reconstruction kernels can be compared after normalization of the IQs. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Optimisation of radiation dose and image quality in mobile neonatal chest radiography.

    Science.gov (United States)

    Hinojos-Armendáriz, V I; Mejía-Rosales, S J; Franco-Cabrera, M C

    2018-05-01

    To optimise the radiation dose and image quality for chest radiography in the neonatal intensive care unit (NICU) by increasing the mean beam energy. Two techniques for the acquisition of NICU AP chest X-ray images were compared for image quality and radiation dose. 73 images were acquired using a standard technique (56 kV, 3.2 mAs and no additional filtration) and 90 images with a new technique (62 kV, 2 mAs and 2 mm Al filtration). The entrance surface air kerma (ESAK) was measured using a phantom and compared between the techniques and against established diagnostic reference levels (DRL). Images were evaluated using seven image quality criteria independently by three radiologists. Images quality and radiation dose were compared statistically between the standard and new techniques. The maximum ESAK for the new technique was 40.20 μGy, 43.7% of the ESAK of the standard technique. Statistical evaluation demonstrated no significant differences in image quality between the two acquisition techniques. Based on the techniques and acquisition factors investigated within this study, it is possible to lower the radiation dose without any significant effects on image quality by adding filtration (2 mm Al) and increasing the tube potential. Such steps are relatively simple to undertake and as such, other departments should consider testing and implementing this dose reduction strategy within clinical practice where appropriate. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  12. Movement analysis of chest MR image under rest breath using realignment of SPM

    International Nuclear Information System (INIS)

    Kitamura, Shigemi; Usui, Shuji; Horiguchi, Takayoshi; Akiyama, Mitoshi

    2007-01-01

    Analyses of diaphragm and chest wall motion are good indicators to evaluate clinical status and pulmonary function before and after surgery for respiratory disease. Noninvasive MR images using fast gradient recalled echo techniques recently have received a great deal of attention for their assessment of inspiratory motion. However, it is laborious to analyze a large number of dynamic MR images. Therefore, we performed movement analyses of chest two-dimensional (2D) MR images by using the public domain software statistical parametric mapping (SPM) Realignment sub-routine, which is commonly used for the motion correction of brain functional MRI analyses. First, dynamic 2D MR images of a glue-stick phantom were measured as a simple reciprocal movement model and were numerically analyzed by the SPM Realignment. The resulting translation to each axis coincided with the measured values. Then the dynamic images of normal volunteers under free breathing were analyzed by the same method, and we found that the inspiratory motions were quantitatively shown as the translation to each axis. These results revealed that the SPM Realignment is a useful tool for screening the magnitude and characteristics of inspiratory motion. (author)

  13. High-resolution magnetic resonance imaging (HR-MRI) of the pleura and chest wall: Normal findings and pathological changes

    International Nuclear Information System (INIS)

    Bittner, R.C.; Schnoy, N.; Schoenfeld, N.; Grassot, A.; Loddenkemper, R.; Lode, H.; Kaiser, D.; Krumhaar, D.; Felix, R.

    1995-01-01

    To determine the value of high-resolution MRI in pleural and chest wall diseases, the normal and pathologic costal pleura and adjacent chest wall between paravertebral and the axillar region were examined with contrast enhanced high-resolution T 1 -weighted MRI images using a surface coil. Normal anatomy was evaluated in 5 healthy volunteers and a normal specimen of the thoracic wall, and correlation was made with corresponding HR-CT and histologic sections. CT-proved focal and diffuse changes of the pleura and the chest wall in 36 patients underwent HR-MRI, and visual comparison of MRI and CT was done retrospectively. Especially sagittal T 1 -weighted HR-MRI images allowed accurate delineation of the peripleural fat layer (PFL) and the innermost intercostal muscle (IIM), which served as landmarks of the intact inner chest wall. PFL and IIM were well delineated in 3/4 patients with tuberculous pleuritis, and in all 7 patients with non-specific pleuritis, as opposed to impairment of the PFL and/or the IIM, which was detected in 15/18 malignancies as a pattern of malignant chest wall involvement. In one case of tuberculous pleural empyema with edema of the inner chest wall HR-MRI produced false positive diagnosis of malignant disease. HR-MRI images improved non-invasive evaluation of pleural and chest wall diseases, and allowed for differentiation of bengin and malignant changes. (orig./MG) [de

  14. Routine chest and abdominal high-pitch CT: An alternative low dose protocol with preserved image quality

    International Nuclear Information System (INIS)

    Amacker, Nadja A.; Mader, Caecilia; Alkadhi, Hatem; Leschka, Sebastian; Frauenfelder, Thomas

    2012-01-01

    Objective: To investigate the radiation dose and image quality of the high-pitch dual source computer tomography (DSCT) for routine chest and abdominal scans. Methods: 130 consecutive patients (62 female, 68 male, median age 55 years) were included. All patients underwent 128-slice high-pitch DSCT (chest n = 99; abdomen n = 84) at a pitch of 3.2. Two observers independently rated image quality using a 4-point score (1: excellent to 4: non-diagnostic). Image noise was measured and operational radiation dose quantities were recorded. An additional group of 132 patients (chest, n = 80; abdomen n = 52) scanned with standard-pitch CT matched for age, gender, and body mass index (BMI) served as control group. Results: Interobserver agreement for image quality rating was good (k = 0.74). Subjective image quality of high-pitch CT was diagnostic in all patients (median score chest; 2, median score abdomen: 2). Image noise of high-pitch CT was comparable to standard-pitch for the chest (p = 0.32) but increased in the abdomen (p < 0.0001). For high-pitch CT radiation dose was 4.4 ± 0.9 mSv (chest) and 6.5 ± 1.2 mSv (abdomen). These values were significantly lower compared to standard-pitch CT (chest: 5.5 ± 1.2 mSv; abdomen: 11.3 ± 3.8 mSv). Conclusion: Based on the technical background high-pitch dual source CT may serve as an alternative scan mode for low radiation dose routine chest and abdominal CT.

  15. Paediatrician awareness of radiation dose and inherent risks in chest imaging studies--a questionnaire study.

    Science.gov (United States)

    Heyer, Christoph M; Hansmann, Jan; Peters, Sören A; Lemburg, Stefan P

    2010-11-01

    To assess paediatricians' knowledge regarding radiation exposure of chest imaging. German paediatricians were surveyed using a questionnaire. Participants were asked to estimate effective dose (ED) of radiographs (CR) and computed tomography (CT). Further questions included dose-saving of paediatric CT-protocols, ALARA principle, and awareness of the link between radiation and cancer development. Length and type of occupation and amount of ordered procedures were evaluated. 137 paediatricians participated with 59% and 39% correctly estimating ED of an adult (0.01-0.1mSv) and newborn CR (0.01-0.1mSv), respectively. ED of an adult chest CT (1-10mSv) was underestimated by 28%, whereas ED of cardiac CT (10-100mSv) was underestimated by 54%. 35% of participants correctly estimated ED of a chest CT in an infant (10-100mSv) which was underestimated by 56%. Neither length nor type of occupation showed significant impact on dose estimations. 14% of paediatricians stated that MRI causes radiation, whereas 4% correctly estimated the potential of paediatric CT-protocols. 15% were familiar with the ALARA principle and 26% were aware of a publication concerning radiation and malignancy. Paediatricians demonstrated an increased level of awareness compared to previous surveys. However, estimation of ED of CT remained difficult. Increased information transfer and education seem pressing in the light of increasing radiological examinations. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  16. Nontuberculous Mycobacterial (NTM) Disease in Immunocompetent Patients: Expanding Image Findings on Chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyo Hyun; Seon, Hyun Ju; Kim, Mok Hee; Choi, Song; Song, Sang Gook; Shin, Sang Soo; Kim, Yun Hyeon; Park, Jin Gyoon [Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2010-04-15

    The aim of this study was to evaluate the chest CT features of nontuberculous mycobacterial (NTM) disease regardless of the specific organisms. This study included 74 consecutive patients (35 men, 39 women; mean age, 63 years; age range, 25-89 years) who were diagnosed with NTM disease according to the American Thoracic Society Guidelines (1997 and 2007) between January 2005 and July 2007. Chest CT images were randomly reviewed by two radiologists with consensus. The most common organism associated with NTM disease is M. avium-intracellulare complex (87.8%), followed by M. abscesses, M. kansasii, and M. chelonae. The most common chest CT finding was a nodular bronchiectatic lesion (n = 35, 46.7%), followed by a cavitary lesion of the upper lobe (n = 21, 28.0%), combined lesions of two prior subtypes (n = 6, 8.0%), consolidative lesion (s) (n = 5, 6.7%), a bronchogenic spreading pulmonary tuberculosis-like lesion (n = 5, 6.7%), a cavitary mass lesion with small satellite nodules (n = 2, 2.7%), and a miliary nodular lesion (n = 1, 1.3%). More than 5 segments were involved in 60 cases (81.1%). The nodular bronchiectatic lesion or cavitary lesion of upper lobe presents with multi-segmental involvement and the occurrence of combined consolidation is indicative of NTM disease

  17. Anthropomorphic chest phantom imaging – The potential for dose creep in computed radiography

    International Nuclear Information System (INIS)

    Ma, W.K.; Hogg, P.; Tootell, A.; Manning, D.; Thomas, N.; Kane, T.; Kelly, J.; McKenzie, M.; Kitching, J.

    2013-01-01

    For film-based radiography the operator had to be exact in the selection of acquisition parameters or the image could easily become under- or over-exposed. By contrast, digital technology allows for a much greater tolerance of acquisition factor selection which would still give an image of acceptable diagnostic quality. In turn this greater tolerance allows for the operator to increase effective dose for little or no penalty in image quality. The purpose of this article is to determine how image quality and lesion visibility vary with effective dose (E) in order to identify how much overexposure could be tolerated within the radiograph. Using an anthropomorphic chest phantom with ground glass lesions we determined how perceptual image quality and E varied over a wide range of acquisition conditions. Perceptual image quality comprised of image quality and lesion visibility. E was calculated using Monte Carlo method; image quality was determined using a two alternative forced choice (2AFC) method and the quality criteria were partly informed from European guidelines. Five clinicians with significant experience in image reading scored the images for quality (intraclass correlation coefficient 0.869). Image quality and lesion visibility had a close correlation (R 2 > 0.8). The tolerance for over-exposure, whilst still acquiring an image of acceptable quality, increases with decreasing kV and increasing source to image distance (SID). The maximum over-exposure factor (ratio of maximum E to minimum E that produce images of acceptable quality) possible was 139 (at 125 cm and 60 kV). Given the phantom had characteristics similar to the human thorax we propose that that potential for overexposure in a human whilst still obtaining an image of acceptable perceptual image quality is very high. Further research into overexposure tolerance and dose creep should be undertaken

  18. Quantitative evaluation of changes in pleural effusion using digital images of the chest

    International Nuclear Information System (INIS)

    Nishiike, Shigeaki; Fujimura, Ichiro; Sagara, Kenji; Sakashita, Keiji

    2000-01-01

    Exposure data recognition (EDR) is a function of FCR that automatically determines the optimal density of images. This function makes it difficult to evaluate changes in pleural effusion on sequential chest CR. We developed a method to quantify the amount of pleural effusion using the digital value and S value of chest CR. We evaluated the efficacy of the method to quantify the amount of pleural effusion using these values of chest CR in clinical settings. The study period was from December 1996 to January 1999. Study 1: Chest CR was carried out before and after pleural cavity drainage in 70 cases. The volume calculated with the method using the digital value and S value of CR [x(ml)] was compared with the drained volume [y1] on both sides. Study 2: Change in pleural effusion was estimated with a method using CT (y2) and with the method using the digital value and S value of CR (x). The relationship of these two data was investigated. Study 1: The regression equations between x and y1 were y1=1.05x+21.1 (r 2 =0.89) on the right side and y1=0.95x+69.7 (r 2 =0.68) on the left side. Study 2: The regression equations between x and y2 were y2=0.75x-1.88 (r 2 =0.70) on the right side and y2=0.87x-1.27 (r 2 =0.65) on the left side. The method using the digital value and S value of CR was effective for quantifying changes in pleural effusion. (author)

  19. Quality image and incident air kerma evaluation in X-ray chest exams

    International Nuclear Information System (INIS)

    Campos de O, P. M.; Do Carmo S, P.; De Sousa L, M. A.; Da Silva, T. A.

    2017-10-01

    The procedures optimization for obtaining diagnostic quality images is an important factor to the patients radiation levels submitted to diagnostic radiology examinations was the lowest as reasonably practicable. Two methodologies for image quality parameters evaluation were applied in the routine of three diagnostic radiology clinics (A, B and C), two with digital image processing and one with chemical processing in Belo Horizonte, Brazil. The incident air kerma was evaluated for the radiographic techniques used in the clinic routine chest exams, approved in accordance with European Image Quality Criteria. It was possible to determine that the Fluke Biomedical X-ray Phantom test objects coupled to the Leeds Test Objects (TOR CDR) obtained better results than Gammex s Radiographic Survey Phantom (RSV), because the low and high contrast structures present in the RSV were not visualized in lower energies. The three clinics presented very similar results in all image quality parameters in the evaluation with the TOR CDR test object. However, clinic C presented an low contrast structures result 28.1 % lower than clinical B, although the average Ka,i to obtain their images was 33.4 % superior. The clinic A results present the best relation between image quality and radiation dose in patients. It was verified the optimization doses possibility in diagnostic radiology services with digital processing system, without significant reduction in image quality. Patients submitted to the highest radiation levels belonged to the clinic that presented the worst results in the image quality parameters evaluated. (Author)

  20. Automated detection system for pulmonary emphysema on 3D chest CT images

    Science.gov (United States)

    Hara, Takeshi; Yamamoto, Akira; Zhou, Xiangrong; Iwano, Shingo; Itoh, Shigeki; Fujita, Hiroshi; Ishigaki, Takeo

    2004-05-01

    An automatic extraction of pulmonary emphysema area on 3-D chest CT images was performed using an adaptive thresholding technique. We proposed a method to estimate the ratio of the emphysema area to the whole lung volume. We employed 32 cases (15 normal and 17 abnormal) which had been already diagnosed by radiologists prior to the study. The ratio in all the normal cases was less than 0.02, and in abnormal cases, it ranged from 0.01 to 0.26. The effectiveness of our approach was confirmed through the results of the present study.

  1. Survey of image quality and radiographic technique of pediatric chest examinations performed in Latin America

    International Nuclear Information System (INIS)

    Khoury, H.; Mora, P.; Defaz, M.Y.; Blanco, S.; Leyton, F.; Benavente, T.; Ortiz Lopez, P.; Ramirez, R.

    2008-01-01

    This work presents the results of a survey of entrance surface air kerma values (K e ), image quality and radiographic exposure parameters used in pediatric chest examinations performed in Latin America. This study is part of the activities of the IAEA Regional Project RLA/9/057 whose objective is to optimize the radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. The survey was performed in nine hospitals in Argentina (1), Brazil (4), Chile (1), Costa Rica (1), Peru (1) and Ecuador (1). The study group consisted of 462 pediatric patients (Group I- from two days to one year, Group II- from four to six years of age) undergoing chest PA/AP examinations. At the time of the examination the exposure parameters (kVp, mAs, focal-spot-to-film distance, etc.) and patient information (gender, height, weight and age) were recorded. The radiographic image quality was evaluated by the local radiologist based on the European Guidelines on Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The results showed that the exposure parameters used on newborn patients were in the majority outside the 60-65kV range recommended by the European Guidelines for a good radiographic practice. In the case of examinations of patients with age between 4 to 6 years, 80% were performed with a peak tube voltage within the 60-80 kV range, as recommended by the European Guidelines. It was found that none of countries fully comply with the European Guidelines on Quality Criteria and those criteria No. 2 and No. 3 (reproduction of the chest without rotation) received the lowest scores. Probably this occurs because there are no proper patient immobilization devices. The Ke values, for both patient groups, showed a wide dispersion, ranged from 10 μGy to 160μGy for the newborn patients and from 20μGy to 240μGy for infant patients. It is possible to conclude that, in the participating Latin American countries on this project

  2. Homogeneous Canine Chest Phantom Construction: A Tool for Image Quality Optimization.

    Directory of Open Access Journals (Sweden)

    Ana Luiza Menegatti Pavan

    Full Text Available Digital radiographic imaging is increasing in veterinary practice. The use of radiation demands responsibility to maintain high image quality. Low doses are necessary because workers are requested to restrain the animal. Optimizing digital systems is necessary to avoid unnecessary exposure, causing the phenomenon known as dose creep. Homogeneous phantoms are widely used to optimize image quality and dose. We developed an automatic computational methodology to classify and quantify tissues (i.e., lung tissue, adipose tissue, muscle tissue, and bone in canine chest computed tomography exams. The thickness of each tissue was converted to simulator materials (i.e., Lucite, aluminum, and air. Dogs were separated into groups of 20 animals each according to weight. Mean weights were 6.5 ± 2.0 kg, 15.0 ± 5.0 kg, 32.0 ± 5.5 kg, and 50.0 ± 12.0 kg, for the small, medium, large, and giant groups, respectively. The one-way analysis of variance revealed significant differences in all simulator material thicknesses (p < 0.05 quantified between groups. As a result, four phantoms were constructed for dorsoventral and lateral views. In conclusion, the present methodology allows the development of phantoms of the canine chest and possibly other body regions and/or animals. The proposed phantom is a practical tool that may be employed in future work to optimize veterinary X-ray procedures.

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging ( ... heart, valves, great vessels, etc.). top of page What are some common uses of the procedure? MR ...

  4. The role of scintimammography with 99m-Tc-Tetrofosmin in breast cancer detection

    International Nuclear Information System (INIS)

    Vonorta, K.; Stefanakos, N.; Anagnostopoulos, K.; Michailidou, E.; Prassopoulos, V.; Baltas, D.; Giatas, A.; Keramopoulos, A.; Papageorgiou, S.

    2002-01-01

    Aim: It is already known that breast cancer is the most common malignancy of women. Breast mammography, although it is of a great importance as a screening test, it has some limitations, especially in women with dense breast tissue, or in those who underwent partial mastectomy and post-surgical scars are present. This resulted in the necessity of the use of other complementary imaging procedures, such as ultrasonography, magnetic resonance imaging and scintimammography with technetium-99m labeled agents (Methyl-Isobutyl-Isonitrile: MIBI) or monoclonal antibodies. In the present study the contribution of scintimammography with 99m- Tc- Tetrofosmin in the diagnosis of breast cancer and/or local relapses is investigated. Material-Methods: 91 women aged 22-72 years old with strong clinical and/or mammographic suspicion of breast cancer and/or local relapse after mastectomy (92 lesions) were investigated. All patients underwent scintimammography with 99m-Tc-Tetrofosmin (dose: 20mCi) before surgery and/or biopsy. An intravenous injection was performed at the contralateral site of that of the suspected or palpable lesion. Imaging was performed 10 minutes post-injection. Patients were at a prone position and lateral and views of the breasts and axillary areas were performed (10 minutes per view, matrix size 128x128, high resolution collimator).Anterior views of the breasts and axillary areas were performed with the patients placed in at supine position. Results: The overall Sensitivity was 85,7%, Specificity was 87,9%, Positive Predictive Value was 81,9%, Negative Predictive Value was 90,7% and Diagnostic Accuracy was 85,3%.Three out of three local relapses were detected,as well as one out of one bilateral involvement. In a case of negative breast scan and positive findings at the axillary area, histology revealed a lymphoma. Conclusions: Scintimammography with 99m-Tc-Tetrofosmin is a valuable method in the detection of primary breast cancer or the early diagnosis of local

  5. Localized Energy-Based Normalization of Medical Images: Application to Chest Radiography.

    Science.gov (United States)

    Philipsen, R H H M; Maduskar, P; Hogeweg, L; Melendez, J; Sánchez, C I; van Ginneken, B

    2015-09-01

    Automated quantitative analysis systems for medical images often lack the capability to successfully process images from multiple sources. Normalization of such images prior to further analysis is a possible solution to this limitation. This work presents a general method to normalize medical images and thoroughly investigates its effectiveness for chest radiography (CXR). The method starts with an energy decomposition of the image in different bands. Next, each band's localized energy is scaled to a reference value and the image is reconstructed. We investigate iterative and local application of this technique. The normalization is applied iteratively to the lung fields on six datasets from different sources, each comprising 50 normal CXRs and 50 abnormal CXRs. The method is evaluated in three supervised computer-aided detection tasks related to CXR analysis and compared to two reference normalization methods. In the first task, automatic lung segmentation, the average Jaccard overlap significantly increased from 0.72±0.30 and 0.87±0.11 for both reference methods to with normalization. The second experiment was aimed at segmentation of the clavicles. The reference methods had an average Jaccard index of 0.57±0.26 and 0.53±0.26; with normalization this significantly increased to . The third experiment was detection of tuberculosis related abnormalities in the lung fields. The average area under the Receiver Operating Curve increased significantly from 0.72±0.14 and 0.79±0.06 using the reference methods to with normalization. We conclude that the normalization can be successfully applied in chest radiography and makes supervised systems more generally applicable to data from different sources.

  6. Potential usefulness of a video printer for producing secondary images from digitized chest radiographs

    Science.gov (United States)

    Nishikawa, Robert M.; MacMahon, Heber; Doi, Kunio; Bosworth, Eric

    1991-05-01

    Communication between radiologists and clinicians could be improved if a secondary image (copy of the original image) accompanied the radiologic report. In addition, the number of lost original radiographs could be decreased, since clinicians would have less need to borrow films. The secondary image should be simple and inexpensive to produce, while providing sufficient image quality for verification of the diagnosis. We are investigating the potential usefulness of a video printer for producing copies of radiographs, i.e. images printed on thermal paper. The video printer we examined (Seikosha model VP-3500) can provide 64 shades of gray. It is capable of recording images up to 1,280 pixels by 1,240 lines and can accept any raster-type video signal. The video printer was characterized in terms of its linearity, contrast, latitude, resolution, and noise properties. The quality of video-printer images was also evaluated in an observer study using portable chest radiographs. We found that observers could confirm up to 90 of the reported findings in the thorax using video- printer images, when the original radiographs were of high quality. The number of verified findings was diminished when high spatial resolution was required (e.g. detection of a subtle pneumothorax) or when a low-contrast finding was located in the mediastinal area or below the diaphragm (e.g. nasogastric tubes).

  7. Tree-structured vector quantization of CT chest scans: Image quality and diagnostic accuracy

    International Nuclear Information System (INIS)

    Cosman, P.C.; Tseng, C.; Gray, R.M.; Olshen, R.A.; Moses, L.E.; Davidson, H.C.; Bergin, C.J.; Riskin, E.A.

    1993-01-01

    The quality of lossy compressed images is often characterized by signal-to-noise ratios, informal tests of subjective quality, or receiver operating characteristic (ROC) curves that include subjective appraisals of the value of an image for a particular application. The authors believe that for medical applications, lossy compressed images should be judged by a more natural and fundamental aspect of relative image quality: their use in making accurate diagnoses. They apply a lossy compression algorithm to medical images, and quantify the quality of the images by the diagnostic performance of radiologists, as well as by traditional signal-to-noise ratios and subjective ratings. The study is unlike previous studies of the effects of lossy compression in that they consider non-binary detection tasks, simulate actual diagnostic practice instead of using paired tests or confidence rankings, use statistical methods that are more appropriate for non-binary clinical data than are the popular ROC curves, and use low-complexity predictive tree-structured vector quantization for compression rather than DCT-based transform codes combined with entropy coding. Their diagnostic tasks are the identification of nodules (tumors) in the lungs and lymphadenopathy in the mediastinum from computerized tomography (CT) chest scans. For the image modality, compression algorithm, and diagnostic tasks they consider, the original 12 bit per pixel (bpp) CT image can be compressed to between 1 bpp and 2 bpp with no significant changes in diagnostic accuracy

  8. A study on the digital image transfer application mass chest X-ray system up-grade

    International Nuclear Information System (INIS)

    Kim, Sun Chil; Park, Jong Sam; Lee, Jon Il

    2003-01-01

    By converting movable indirect mass chest X-ray devices for vehicles into digital systems and upgrading it to share information with the hospital's medical image information system, excellencies have been confirmed as a result of installing and running this type of system and are listed hereinafter. Upgrading analog systems, such as indirect mass chest X-ray devices dependent on printed film, to digital systems allows them to be run and managed much more efficiently, contributing to the increase in the stability and the efficiency of the system. Unlike existing images, communication based on DICOM standards allow images to be compatible with the hospital's outer and inner network PACS systems, extending the scope of the radiation departments information system. Assuming chest-exclusive indirect mass chest X-rays, a linked development of CAD (Computer Aided Diagnosis, Detector) becomes possible. By applying wireless Internet, Web-PACS for movable indirect mass chest X-ray devices for vehicles will become possible. Research in these fields must continue and if the superior image quality and convenience of digital systems are confirmed, I believe that the conversion of systems still dependent on analog images to modernized digital systems is a must

  9. A method for smoothing segmented lung boundary in chest CT images

    Science.gov (United States)

    Yim, Yeny; Hong, Helen

    2007-03-01

    To segment low density lung regions in chest CT images, most of methods use the difference in gray-level value of pixels. However, radiodense pulmonary vessels and pleural nodules that contact with the surrounding anatomy are often excluded from the segmentation result. To smooth lung boundary segmented by gray-level processing in chest CT images, we propose a new method using scan line search. Our method consists of three main steps. First, lung boundary is extracted by our automatic segmentation method. Second, segmented lung contour is smoothed in each axial CT slice. We propose a scan line search to track the points on lung contour and find rapidly changing curvature efficiently. Finally, to provide consistent appearance between lung contours in adjacent axial slices, 2D closing in coronal plane is applied within pre-defined subvolume. Our method has been applied for performance evaluation with the aspects of visual inspection, accuracy and processing time. The results of our method show that the smoothness of lung contour was considerably increased by compensating for pulmonary vessels and pleural nodules.

  10. Usefulness of computerized method for lung nodule detection on digital chest radiographs using similar subtraction images from different patients

    International Nuclear Information System (INIS)

    Aoki, Takatoshi; Oda, Nobuhiro; Yamashita, Yoshiko; Yamamoto, Keiji; Korogi, Yukunori

    2012-01-01

    Purpose: The purpose of this study is to evaluate the usefulness of a novel computerized method to select automatically the similar chest radiograph for image subtraction in the patients who have no previous chest radiographs and to assist the radiologists’ interpretation by presenting the “similar subtraction image” from different patients. Materials and methods: Institutional review board approval was obtained, and the requirement for informed patient consent was waived. A large database of approximately 15,000 normal chest radiographs was used for searching similar images of different patients. One hundred images of candidates were selected according to two clinical parameters and similarity of the lung field in the target image. We used the correlation value of chest region in the 100 images for searching the most similar image. The similar subtraction images were obtained by subtracting the similar image selected from the target image. Thirty cases with lung nodules and 30 cases without lung nodules were used for an observer performance test. Four attending radiologists and four radiology residents participated in this observer performance test. Results: The AUC for all radiologists increased significantly from 0.925 to 0.974 with the CAD (P = .004). When the computer output images were available, the average AUC for the residents was more improved (0.960 vs. 0.890) than for the attending radiologists (0.987 vs. 0.960). Conclusion: The novel computerized method for lung nodule detection using similar subtraction images from different patients would be useful to detect lung nodules on digital chest radiographs, especially for less experienced readers.

  11. Fundamental imaging characteristics of a slot-scan digital chest radiographic system

    International Nuclear Information System (INIS)

    Samei, Ehsan; Saunders, Robert S.; Lo, Joseph Y.; Dobbins, James T. III; Jesneck, Jonathan L.; Floyd, Carey E.; Ravin, Carl E.

    2004-01-01

    Our purpose in this study was to evaluate the fundamental image quality characteristics of a new slot-scan digital chest radiography system (ThoraScan, Delft Imaging Systems/Nucletron, Veenendaal, The Netherlands). The linearity of the system was measured over a wide exposure range at 90, 117, and 140 kVp with added Al filtration. System uniformity and reproducibility were established with an analysis of images from repeated exposures. The modulation transfer function (MTF) was evaluated using an established edge method. The noise power spectrum (NPS) and the detective quantum efficiency (DQE) of the system were evaluated at the three kilo-voltages over a range of exposures. Scatter fraction (SF) measurements were made using a posterior beam stop method and a geometrical chest phantom. The system demonstrated excellent linearity, but some structured nonuniformities. The 0.1 MTF values occurred between 3.3-3.5 mm -1 . The DQE(0.15) and DQE(2.5) were 0.21 and 0.07 at 90 kVp, 0.18 and 0.05 at 117 kVp, and 0.16 and 0.03 at 140 kVp, respectively. The system exhibited remarkably lower SFs compared to conventional full-field systems with anti-scatter grid, measuring 0.13 in the lungs and 0.43 in the mediastinum. The findings indicated that the slot-scan design provides marked scatter reduction leading to high effective DQE (DQE eff ) of the system and reduced patient dose required to achieve high image quality

  12. Improvement in visibility of simulated lung nodules on computed radiography (CR) chest images by use of temporal subtraction technique

    International Nuclear Information System (INIS)

    Oda, Nobuhiro; Fujimoto, Keiji; Murakami, Seiichi; Katsuragawa, Shigehiko; Doi, Kunio; Nakata, Hajime

    1999-01-01

    A temporal subtraction image obtained by subtraction of a previous image from a current one can enhance interval change on chest images. In this study, we compared the visibility of simulated lung nodules on CR images with and without temporal subtraction. Chest phantom images without and with simulated nodules were obtained as previous and current images, respectively, by a CR system. Then, subtraction images were produced with an iterative image warping technique. Twelve simulated nodules were attached on various locations of the chest phantom. The diameter of nodules having a CT number of 47 ranged from 3 mm to 10 mm. Seven radiologists subjectively evaluated the visibility of simulated nodules on CR images with and without temporal subtraction using a three-point rating scale (0: invisible, +1: questionable, +2:visible). The minimum diameter of simulated nodules visible at a frequency greater than 50% was 4 mm on the CR images with temporal subtraction and 6 mm on those without. Our results indicated that the subtraction images clearly improved the visibility of simulated nodules. (author)

  13. Impaired exercise-related myocardial uptake of technetium-99m-tetrofosmin in relation to coronary narrowing and diabetic state

    International Nuclear Information System (INIS)

    Sasao, Hisataka; Nakata, Tomoaki; Tsuchihashi, Kazufumi; Wakabayashi, Takeru; Nakahara, Norifumi; Doi, Atsushi; Hashimoto, Akiyoshi; Kobayashi, Hiroshi; Shimamoto, Kazuaki

    2001-01-01

    Despite the diagnostic efficacy of stress myocardial perfusion imaging, the correlation between the actual perfusion tracer activity and diseased state of a coronary artery has not been studied in detail. We estimated exercise-related perfusion augmentation in relation to disease states of a coronary artery in diabetic and non-diabetic patients by a newly developed quantitative technetium (Tc)-99m-tetrofosmin myocardial imaging technique. Tc-99m-tetrofosmin tomographic imaging with an exercise-rest protocol was performed in 26 stable coronary patients and in 8 age-matched controls. Percent increase (%IR) in myocardial count during symptom-limited submaximal exercise-stress was calculated in 16 non-infarcted polar map segments and in each coronary territory by a subtraction technique with corrections for physical decay and injected tracer doses, and the results were compared with those of angiographically quantified coronary diameter stenosis (%DS). Percent IR and peak heart rate during exercise showed a positive linear correlation both in coronary territories with significant stenosis (%DS≥75%) and in control or non-stenotic (%DS<75%) territories. The regression line in stenotic regions was, however, significantly (p<0.01) shifted downward compared to that in non-stenotic regions. Percent IR in stenotic regions showed a significant inverse correlation with %DS. Coronary stenosis of 75% or more was identified by a %IR cutoff value of 40% with 77% sensitivity, 70% specificity, and an accuracy of 72%. In coronary territories with a %DS of less than 75%, %IR in diabetic patients was significantly lower (46±15%) than that in non-diabetic patients (61±25%). Thus, blunted exercise-related augmentation of myocardial uptake of Tc-99m-tetrofosmin correlates with the severity of coronary narrowing and diabetic state. (author)

  14. Acute chest pain: The role of MR imaging and MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hunold, Peter, E-mail: peter.hunold@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Bischoff, Peter, E-mail: peter.bischoff@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Barkhausen, Jörg, E-mail: joerg.barkhausen@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Vogt, Florian M., E-mail: florian.vogt@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany)

    2012-12-15

    MR imaging (MRI) and MR angiography (MRA) have gained a high level of diagnostic accuracy in cardiovascular disease. MRI in cardiac disease has been established as the non-invasive standard of reference in many pathologies. However, in acute chest pain the situation is somewhat special since many of the patients presenting in the emergency department suffer from potentially life-threatening disease including acute coronary syndrome, pulmonary embolism, and acute aortic syndrome. Those patients need a fast and definitive evaluation under continuous monitoring of vital parameters. Due to those requirements MRI seems to be less suitable compared to X-ray coronary angiography and multislice computed tomography angiography (CTA). However, MRI allows for a comprehensive assessment of all clinically stable patients providing unique information on the cardiovascular system including ischemia, inflammation and function. Furthermore, MRI and MRA are considered the method of choice in patients with contraindications to CTA and for regular follow-up in known aortic disease. This review addresses specific features of MRI and MRA for different cardiovascular conditions presenting with acute chest pain.

  15. Three-dimensional automatic computer-aided evaluation of pleural effusions on chest CT images

    Science.gov (United States)

    Bi, Mark; Summers, Ronald M.; Yao, Jianhua

    2011-03-01

    The ability to estimate the volume of pleural effusions is desirable as it can provide information about the severity of the condition and the need for thoracentesis. We present here an improved version of an automated program to measure the volume of pleural effusions using regular chest CT images. First, the lungs are segmented using region growing, mathematical morphology, and anatomical knowledge. The visceral and parietal layers of the pleura are then extracted based on anatomical landmarks, curve fitting and active contour models. The liver and compressed tissues are segmented out using thresholding. The pleural space is then fitted to a Bezier surface which is subsequently projected onto the individual two-dimensional slices. Finally, the volume of the pleural effusion is quantified. Our method was tested on 15 chest CT studies and validated against three separate manual tracings. The Dice coefficients were 0.74+/-0.07, 0.74+/-0.08, and 0.75+/-0.07 respectively, comparable to the variation between two different manual tracings.

  16. Double-phase Tc-99m tetrofosmin parathyroid scan in hyperparathyroidism: comparison with ultrasonography

    International Nuclear Information System (INIS)

    Kim, In Soo; Kim, Sang Yoon; Zeon, Seok Kil; Won, Kyoung Sook

    2004-01-01

    This study was performed to evaluate the utility of double-phase Tc-99m Tetrofosmin(TF) parathyroid scan in the detection of pathologic lesions of primary hyperparathyroidism, and comparison with the ultrasonography(US). The double phase TF parathyroid scan of the anterior neck including upper mediastinum with 800 MBq TF were acquired at ten minutes (early phase) and at two hours (delayed phase) after radiopharmaceutical injection, in 24 consecutive patients under the clinical impression of primary hyperparathyroidism and hypercalcaemia. The images were evaluated for abnormal focal areas of increased tracer localization in the anterior neck and superior mediastinum in early phase, and visualization of parathyroid gland radioactivity after wash-out of the thyroid gland radioactivity in delayed phase. US of the anterior neck including upper mediastinum was performed by a diagnostic radiologist in 24 consecutive patients, within one week before or after the scan. The findings of double phase TF parathyroid scan and US were compared with the pathologic results. Ten of 24 patients were surgically explored and pathologic results showed eight adenomas and two hyperplasia. The double phase TF parathyroid scan showed positive findings in seven patients of eight adenomas and one patient of two hyperplasia patients. US image showed positive findings in six patients of eight adenomas and no positive findings of two hyperplasia. The sensitivity of the double phase TF scan for detection of the causes of the primary hyperparathyroidism was 80% and US was 60%. The double phase Tc-99m Tetrofosmin parathyroid scan showed higher sensitivity in detection of the pathologic lesions of primary hyperparathyroidism than ultrasonography

  17. Comparison of image quality and effective dose by additional filtration on digital chest tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kye Sun [Dept. of Dignostic Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Sung Chul [Dept. of Radiological Science, Gachon University, Sungnam (Korea, Republic of)

    2015-12-15

    The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.

  18. Value of a Computer-aided Detection System Based on Chest Tomosynthesis Imaging for the Detection of Pulmonary Nodules.

    Science.gov (United States)

    Yamada, Yoshitake; Shiomi, Eisuke; Hashimoto, Masahiro; Abe, Takayuki; Matsusako, Masaki; Saida, Yukihisa; Ogawa, Kenji

    2018-04-01

    Purpose To assess the value of a computer-aided detection (CAD) system for the detection of pulmonary nodules on chest tomosynthesis images. Materials and Methods Fifty patients with and 50 without pulmonary nodules underwent both chest tomosynthesis and multidetector computed tomography (CT) on the same day. Fifteen observers (five interns and residents, five chest radiologists, and five abdominal radiologists) independently evaluated tomosynthesis images of 100 patients for the presence of pulmonary nodules in a blinded and randomized manner, first without CAD, then with the inclusion of CAD marks. Multidetector CT images served as the reference standard. Free-response receiver operating characteristic analysis was used for the statistical analysis. Results The pooled diagnostic performance of 15 observers was significantly better with CAD than without CAD (figure of merit [FOM], 0.74 vs 0.71, respectively; P = .02). The average true-positive fraction and false-positive rate per all cases with CAD were 0.56 and 0.26, respectively, whereas those without CAD were 0.47 and 0.20, respectively. Subanalysis showed that the diagnostic performance of interns and residents was significantly better with CAD than without CAD (FOM, 0.70 vs 0.62, respectively; P = .001), whereas for chest radiologists and abdominal radiologists, the FOM with CAD values were greater but not significantly: 0.80 versus 0.78 (P = .38) and 0.74 versus 0.73 (P = .65), respectively. Conclusion CAD significantly improved diagnostic performance in the detection of pulmonary nodules on chest tomosynthesis images for interns and residents, but provided minimal benefit for chest radiologists and abdominal radiologists. © RSNA, 2017 Online supplemental material is available for this article.

  19. Study of dosimetric quantities and image quality in pediatric examinations of chest and abdomen computed tomography

    International Nuclear Information System (INIS)

    Jornada, Tiago da Silva

    2013-01-01

    This work had the objective to achieve the knowledge of the dosimetric quantities related to chest and abdomen computed tomography (CT) examinations of pediatric patients, in Belo Horizonte city. The reason of this work is based on the fact that the probability of health detriment in children, which it may be caused by radiation, is higher than in adults. Besides, although in many countries the knowledge and control of patient doses is a normal procedure, this safety culture does not exist in Brazil. Another objective of this work was to compare the dosimetric quantity values with the Diagnostic Reference Levels (DRLs); when it was needed, an optimization process was applied and the quality of the diagnostic image obtained with the optimized technical parameters was analyzed. This study was carried out in five hospitals, where the weighted air kerma index (Cw), the volumetric air kerma index (Cvol), the air kerma - length product (PKL,CT), the Effective Dose (E) and the Normalized Effective Dose (En) were determined; three methods were adopted for measurements: the ionization chamber inside a chest pediatric phantom, radiochromic films and the CT-EXPO software. The optimization process was applied to a single hospital through variations in the current (mA) and voltage (kV) of the x-ray tube for the protocols used for abdomen CT examinations. The analysis of the quality of the diagnostic image was done by Normal Distribution and ROC analysis; spatial resolution analysis was used through MTF determination and the noise level was judged in terms quantitative and qualitative. Results of the dosimetric quantities showed that they significantly differed between single-slice and multi-slice tomography units, but their values were always below the recommended DRLs. The optimized values of the dosimetric quantities obtained after the optimization process showed that it was possible to reduce the radiation exposure of pediatric patient without losing the image quality

  20. Adaptive wiener filter based on Gaussian mixture distribution model for denoising chest X-ray CT image

    International Nuclear Information System (INIS)

    Tabuchi, Motohiro; Yamane, Nobumoto; Morikawa, Yoshitaka

    2008-01-01

    In recent decades, X-ray CT imaging has become more important as a result of its high-resolution performance. However, it is well known that the X-ray dose is insufficient in the techniques that use low-dose imaging in health screening or thin-slice imaging in work-up. Therefore, the degradation of CT images caused by the streak artifact frequently becomes problematic. In this study, we applied a Wiener filter (WF) using the universal Gaussian mixture distribution model (UNI-GMM) as a statistical model to remove streak artifact. In designing the WF, it is necessary to estimate the statistical model and the precise co-variances of the original image. In the proposed method, we obtained a variety of chest X-ray CT images using a phantom simulating a chest organ, and we estimated the statistical information using the images for training. The results of simulation showed that it is possible to fit the UNI-GMM to the chest X-ray CT images and reduce the specific noise. (author)

  1. Small lung cancers: improved detection by use of bone suppression imaging--comparison with dual-energy subtraction chest radiography.

    Science.gov (United States)

    Li, Feng; Engelmann, Roger; Pesce, Lorenzo L; Doi, Kunio; Metz, Charles E; Macmahon, Heber

    2011-12-01

    To determine whether use of bone suppression (BS) imaging, used together with a standard radiograph, could improve radiologists' performance for detection of small lung cancers compared with use of standard chest radiographs alone and whether BS imaging would provide accuracy equivalent to that of dual-energy subtraction (DES) radiography. Institutional review board approval was obtained. The requirement for informed consent was waived. The study was HIPAA compliant. Standard and DES chest radiographs of 50 patients with 55 confirmed primary nodular cancers (mean diameter, 20 mm) as well as 30 patients without cancers were included in the observer study. A new BS imaging processing system that can suppress the conspicuity of bones was applied to the standard radiographs to create corresponding BS images. Ten observers, including six experienced radiologists and four radiology residents, indicated their confidence levels regarding the presence or absence of a lung cancer for each lung, first by using a standard image, then a BS image, and finally DES soft-tissue and bone images. Receiver operating characteristic (ROC) analysis was used to evaluate observer performance. The average area under the ROC curve (AUC) for all observers was significantly improved from 0.807 to 0.867 with BS imaging and to 0.916 with DES (both P chest radiographs. Further improvements can be achieved by use of DES radiography but with the requirement for special equipment and a potential small increase in radiation dose. © RSNA, 2011.

  2. Analysis of image quality according to BMI of digital chest radiography: Focusing on bureau of radiological health evaluation

    International Nuclear Information System (INIS)

    Jin, Seong Jin; Im, In Chul; Cho, Ji Hwan

    2017-01-01

    Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was 30.17±4.73 and the average waist circumference was 66.91±4.67 cm. The mean Body Mass Index value was 20.21±2.23, the mean value of mAs was 3.04±0.78, and the mean value of Bureau of Radiological Health was 79.83±8.45. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality

  3. Analysis of image quality according to BMI of digital chest radiography: Focusing on bureau of radiological health evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Seong Jin [Gammaknife center, Inje University Haeundae Paik Hospital, Busan (Korea, Republic of); Im, In Chul [Dept. of Radiological Science, Dongeui University, Busan (Korea, Republic of); Cho, Ji Hwan [Dept. of Health Care Clinic, Inje University Busan Paik Hospital, Busan (Korea, Republic of)

    2017-03-15

    Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was 30.17±4.73 and the average waist circumference was 66.91±4.67 cm. The mean Body Mass Index value was 20.21±2.23, the mean value of mAs was 3.04±0.78, and the mean value of Bureau of Radiological Health was 79.83±8.45. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

  4. Homogeneous Canine Chest Phantom Construction: A Tool for Image Quality Optimization.

    Science.gov (United States)

    Pavan, Ana Luiza Menegatti; Rosa, Maria Eugênia Dela; Giacomini, Guilherme; Bacchim Neto, Fernando Antonio; Yamashita, Seizo; Vulcano, Luiz Carlos; Duarte, Sergio Barbosa; Miranda, José Ricardo de Arruda; de Pina, Diana Rodrigues

    2016-01-01

    Digital radiographic imaging is increasing in veterinary practice. The use of radiation demands responsibility to maintain high image quality. Low doses are necessary because workers are requested to restrain the animal. Optimizing digital systems is necessary to avoid unnecessary exposure, causing the phenomenon known as dose creep. Homogeneous phantoms are widely used to optimize image quality and dose. We developed an automatic computational methodology to classify and quantify tissues (i.e., lung tissue, adipose tissue, muscle tissue, and bone) in canine chest computed tomography exams. The thickness of each tissue was converted to simulator materials (i.e., Lucite, aluminum, and air). Dogs were separated into groups of 20 animals each according to weight. Mean weights were 6.5 ± 2.0 kg, 15.0 ± 5.0 kg, 32.0 ± 5.5 kg, and 50.0 ± 12.0 kg, for the small, medium, large, and giant groups, respectively. The one-way analysis of variance revealed significant differences in all simulator material thicknesses (p optimize veterinary X-ray procedures.

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Chest Magnetic resonance imaging (MRI) ... clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in ...

  6. Chest Pain with Normal Thallium-201 Myocardial Perfusion Image – Is It Really Normal?

    Science.gov (United States)

    Liu, Pang-Yen; Lin, Wen-Yu; Lin, Li-Fan; Lin, Chin-Sheng; Lin, Wei-Shiang; Cheng, Shu-Meng; Yang, Shih-Ping; Liou, Jun-Ting

    2016-01-01

    Background Thallium-201 myocardial perfusion image (MPI) is commonly used to detect coronary artery disease in patients with chest pain. Although a normal thallium-201 MPI result is generally considered to be a good prognosis and further coronary angiogram is not recommended, there are still a few patients who suffer from unexpected acute coronary events. The aim of this study was to investigate the clinical prognosis in patients with normal thallium-201 MPI. Methods From January 2006 to August 2012, a total 22,003 patients undergoing thallium-201 MPI in one tertiary center were screened. Of these, 8092 patients had normal results and were investigated retrospectively. During follow-up, 54 patients underwent coronary angiogram because of refractory typical angina pectoris or unexpected acute coronary events. These 54 patients were divided into 2 groups: group I consisted of 26 (48.1%) patients with angiography-proven significant coronary artery stenosis, and group II consisted of 28 (51.9%) patients without significant stenosis. Results Patients in group I had a higher prevalence of prior coronary stenting and electrocardiographic features of ST depression compared with patients in group II. The multivariate analysis demonstrated that both prior coronary stenting and ST depression were risk predictors of unexpected acute coronary events in the patients with normal thallium-201 MPI [odds ratio (OR), 5.93; 95% confidence interval (CI): 1.03-34.06, p = 0.05 and OR, 7.10; 95% CI: 1.28-39.51, p = 0.03,respectively]. Conclusions Although there is a low incidence of unexpected acute coronary events in patients with chest pain and normal thallium-201 MPI, physicians should be aware of the potentials risk in certain patients in this specific population. PMID:27274174

  7. Single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin combined with SPECT technique in patients with secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Botushanova, A.; Yaneva, M.; Botushanov, N.

    2015-01-01

    Full text: Preoperative parathyroid scintigraphy is highly beneficial when used for minimally invasive parathyroidectomy. The aim is to examine the diagnostic value of single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-etrofosmin combined with SPECT technique in preoperative localization of hyperplastic parathyroid glands in patients with secondary hyperparathyroidism. The study included 15 patients aged 37 to 73 years (8 women and 7 men) with proven secondary hyperparathyroidism with increased serum calcium and parathyroid hormone. All patients were on chroniodialysis and treatment with Calcitriol. The examination was done with two-headed SPECT gamma camera SIMBIA by protocol for single isotope dual-phase scintigraphy and SPECT technique. 740 MBq 99mTc-MIBI were applied intravenously in 6 of the patients, and in 9 patients were administered 740 MBq 99mTc-tetrofosmin. The scintigraphy with 99mTc-MIBI visualized a focus of residual activity in 4 patients, and in 2 we received negative scintigraphy. The scintigraphy with 99mTc-tetrofosmin combined with SPECT showed an area of hyperfixation in both phases on SPECT images in 1 patient. In 2 patients hyperfixating areas suspicious for abnormal parathyroid glands were registered only in the early SPECT images. In 6 patients the scintigraphic results were negative. Negative scintigraphic results can be explained with the ability to suppress the uptake of 99mTc-MIBI and 99mTc - tetrofosmin by the parathyroid cells as a result of taking Calcitriol. Scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin did not show high sensitivity in identifying the hyperplastic parathyroid glands, although it was capable to distinguish patients with nodular hyperplasia of those with diffuse hyperplasia

  8. Cine magnetic resonance imaging, computed tomography and ultrasonography in the evaluation of chest wall invasion of lung cancer

    International Nuclear Information System (INIS)

    Yokozaki, Michiya; Nawano, Shigeru; Nagai, Kanji; Moriyama, Noriyuki; Kodama, Tetsuro; Nishiwaki, Yutaka.

    1997-01-01

    To assess the usefulness of cine-magnetic resonance imaging (cine-MRI) in the evaluation of chest wall invasion, we compared the results of cine-MRI with those of computed tomography (CT) and ultrasonography (US). Eleven patients were examined who had no pain and who were difficult to diagnose by routine examinations. MRI was performed with a Magnetom SP/4000, 1.5T unit (Siemens, Germany). For cine imaging, continuous turbo-FLUSH (ultra fast low angle shot) images were obtained at an orthogonal section to the chest wall during slow deep breathing. A CT scan was performed using a TCT 900S or Super Helix (Toshiba, Japan) at 1 cm intervals, with section thicknesses of 1 cm throughout the entire chest. US was performed with a model SSA-270A (Toshiba, Japan) with 7.5-MHz linear array scanners (PLF-705S; Toshiba, Japan). Sensitivity, specificity and accuracy were 67%, 75% and 73% for cine MRI, 67%, 63% and 64% for CT, 33%, 75% and 64% for US, respectively. These results indicate that cine MRI is potentially useful for the diagnosis of chest wall invasion of lung cancer. (author)

  9. Application of off-line image processing for optimization in chest computed radiography using a low cost system.

    Science.gov (United States)

    Muhogora, Wilbroad E; Msaki, Peter; Padovani, Renato

    2015-03-08

     The objective of this study was to improve the visibility of anatomical details by applying off-line postimage processing in chest computed radiography (CR). Four spatial domain-based external image processing techniques were developed by using MATLAB software version 7.0.0.19920 (R14) and image processing tools. The developed techniques were implemented to sample images and their visual appearances confirmed by two consultant radiologists to be clinically adequate. The techniques were then applied to 200 chest clinical images and randomized with other 100 images previously processed online. These 300 images were presented to three experienced radiologists for image quality assessment using standard quality criteria. The mean and ranges of the average scores for three radiologists were characterized for each of the developed technique and imaging system. The Mann-Whitney U-test was used to test the difference of details visibility between the images processed using each of the developed techniques and the corresponding images processed using default algorithms. The results show that the visibility of anatomical features improved significantly (0.005 ≤ p ≤ 0.02) with combinations of intensity values adjustment and/or spatial linear filtering techniques for images acquired using 60 ≤ kVp ≤ 70. However, there was no improvement for images acquired using 102 ≤ kVp ≤ 107 (0.127 ≤ p ≤ 0.48). In conclusion, the use of external image processing for optimization can be effective in chest CR, but should be implemented in consultations with the radiologists.

  10. Consequence of Mycobacterium avium complex pulmonary disease judging from the change of the chest CT image

    International Nuclear Information System (INIS)

    Fujiwara, Kiyohiro

    2008-01-01

    The long term consequence of the disease in Mycobacterium avium complex pulmonary disease (MACPD) is scarcely reported. This paper describes consequences of CT images and clinical symptoms in MACPD patients with rather poorer prognosis than usual during chemotherapy for one or more years in authors' hospital until May 2007. Subjects are 17 patients (average age 65.3 y, M 6/F 11) diagnosed as MACPD by the criteria by Jap. Soc. Tuberculosis (2003), whose follow up period is 14-105 (av. 58.1) months, and are classified in tuberculoid type (tt, 2 cases), bronchiectasis post surgery (2) and bronchia type (bt, 13, mostly primary MACPD). Chemotherapy is done with clarithromycin (CAM)+ethambutol (EB)+rifampicin (RHP) (+streptomycin (SM) for progression). Consequences of typical chest CT images are presented for each classification in this paper. Cavitation is seen even in bt as well as in tt and, if observed, the disease tends to deteriorate. In the secondary MACPD post surgery, the exacerbation of clinical symptom is often more severe despite slow changes in CT finding than in bt. Thus, careful follow up is necessary for the two cases above. (R.T.)

  11. Chocolate intake may reduce liver count in 99m-Tc-tetrofosmin myocardial SPECT

    International Nuclear Information System (INIS)

    Tsunekawa, Akikazu; Yasuda, Eisuke; Okuda, Seiji

    2005-01-01

    The accumulation of 99m-Tc-Tetrofosmin (TF) in the liver and intestine may often interfere the image quality of myocardial TF SPECT. Although milk intake before acquisition is recommended to reduce its accumulation by enhancing biliary excretion of TF, some patients cannot accept milk. To elucidate the efficacy of chocolate intake as a substitute for milk, we investigated 72 patients with coronary heart disease who underwent TF SPECT (stress imaging; n=36, rest imaging; n=36). Following injection of TF, the patients were randomly treated either with milk (n=24), or chocolate (n=24). The images were acquired before treatment, at 15 min, at 30 min, and 45 min after treatment. The ratio of liver to heart count (LHR) was calculated and was compared between the two groups. LHR in the stress imaging was not significantly different between the milk-treated and chocolate-treated groups: 1.86 vs 1.87 before treatment, 1.39 vs 1.39 at 30 min, and 1.02 vs 1.03 at 45 min. LHR in the rest imaging was also the same between the two groups: 1.43 vs 1.42 before treatment, 1.22 vs 1.21 at 15 min, and 0.95 vs. 0.95 at 30 min. Chocolate intake may be equally effective to milk intake in reducing the liver accumulation of TF. (author)

  12. Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages

    International Nuclear Information System (INIS)

    Sandborg, Michael; Tingberg, Anders; Ullman, Gustaf; Dance, David R.; Alm Carlsson, Gudrun

    2006-01-01

    The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists' observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x-ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal-to-noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen-film radiography are discussed, as well as the relevance of using VGAS and quantum-noise SNR as measures of image quality in pelvis and chest radiography

  13. Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography

    International Nuclear Information System (INIS)

    Lee, In Ja; Kim, You Hyun; Kim, Chang Nam; Kim, Chang Nam; Lee, Chang Yeob; Park, Kye Yeon

    2009-01-01

    To find out proper photographing conditions in the chest DR imaging, the evaluation of images using the C-D phantom was carried out on relationship of identification capability, graininess, and exposure ratio. The conclusions were obtained as follows. 1. The patient's entrance skin Exposure (ESE) was decreased as tube voltage was increased. 2. According to the tube voltage change, the C-D phantom's identification capability of the exposure conditions was most visible at 110 kVp. 3. The identification capability according to the exposure ratio (mAs) change was most visible at 90 kVp for 0.5 times of low exposure ratio and at 110 kVp for 1.5 times. Therefore, it is known that the images were able to be better identified at a high exposure than a low exposure. 4. The graininess according to the exposure ratio at tube voltage of 110 kVp resulted in the best thing at 1.5 times of ratio when the exposure ratio was 1.5 times increased and the tube voltage was changed, the graininess showed the best result at 110 kVp. Therefore, the patient's exposure dose was low when kVp was increased and the adequate kVp was found to be 110. The image was better identified when exposure ratio was 1.5 times compared to 1.0 times. The graininess was also good when the exposure ratio became 1.5 times. The tube voltage was good at 110 kVp. However, once the exposure ratio is increased, the amount of radiation dose that the patients received get increased, so that the exposure condition has to be thoroughly considered.

  14. Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Ja [Dept. of Radiologic Tecnology, Dongnam Health College, Suwon (Korea, Republic of); Kim, You Hyun; Kim, Chang Nam [Dept. of Radiological Science, College of Health Science, Korea University, Seoul (Korea, Republic of); Kim, Chang Nam; Lee, Chang Yeob; Park, Kye Yeon [Dept. of Diagnostic Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of)

    2009-03-15

    To find out proper photographing conditions in the chest DR imaging, the evaluation of images using the C-D phantom was carried out on relationship of identification capability, graininess, and exposure ratio. The conclusions were obtained as follows. 1. The patient's entrance skin Exposure (ESE) was decreased as tube voltage was increased. 2. According to the tube voltage change, the C-D phantom's identification capability of the exposure conditions was most visible at 110 kVp. 3. The identification capability according to the exposure ratio (mAs) change was most visible at 90 kVp for 0.5 times of low exposure ratio and at 110 kVp for 1.5 times. Therefore, it is known that the images were able to be better identified at a high exposure than a low exposure. 4. The graininess according to the exposure ratio at tube voltage of 110 kVp resulted in the best thing at 1.5 times of ratio when the exposure ratio was 1.5 times increased and the tube voltage was changed, the graininess showed the best result at 110 kVp. Therefore, the patient's exposure dose was low when kVp was increased and the adequate kVp was found to be 110. The image was better identified when exposure ratio was 1.5 times compared to 1.0 times. The graininess was also good when the exposure ratio became 1.5 times. The tube voltage was good at 110 kVp. However, once the exposure ratio is increased, the amount of radiation dose that the patients received get increased, so that the exposure condition has to be thoroughly considered.

  15. Lung nodule detection in pediatric chest CT: quantitative relationship between image quality and radiologist performance.

    Science.gov (United States)

    Li, Xiang; Samei, Ehsan; Barnhart, Huiman X; Gaca, Ana Maria; Hollingsworth, Caroline L; Maxfield, Charles M; Carrico, Caroline W T; Colsher, James G; Frush, Donald P

    2011-05-01

    To determine the quantitative relationship between image quality and radiologist performance in detecting small lung nodules in pediatric CT. The study included clinical chest CT images of 30 pediatric patients (0-16 years) scanned at tube currents of 55-180 mA. Calibrated noise addition software was used to simulate cases at three nominal mA settings: 70, 35, and 17.5 mA, resulting in quantum noise of 7-32 Hounsfield Unit (HU). Using a validated nodule simulation technique, lung nodules with diameters of 3-5 mm and peak contrasts of 200-500 HU were inserted into the cases, which were then randomized and rated independently by four experienced pediatric radiologists for nodule presence on a continuous scale from 0 (definitely absent) to 100 (definitely present). The receiver operating characteristic (ROC) data were analyzed to quantify the relationship between diagnostic accuracy (area under the ROC curve, AUC) and image quality (the product of nodule peak contrast and displayed diameter to noise ratio, CDNR display). AUC increased rapidly from 0.70 to 0.87 when CDNR display increased from 60 to 130 mm, followed by a slow increase to 0.94 when CDNR display further increased to 257 mm. For the average nodule diameter (4 mm) and contrast (350 HU), AUC decreased from 0.93 to 0.71 with noise increased from 7 to 28 HU. We quantified the relationship between image quality and the performance of radiologists in detecting lung nodules in pediatric CT. The relationship can guide CT protocol design to achieve the desired diagnostic performance at the lowest radiation dose.

  16. Usefulness of technetium-99m tetrofosmin liver imaging to detect hepatocellular carcinoma and related to expression of P-glycoprotein or multidrug resistance associated protein-a preliminary report

    International Nuclear Information System (INIS)

    Ding, H.J.; Huang, W.T.; Tsai, C.S.; Chang, C.S.; Kao, A.

    2003-01-01

    Technetium-99m Tetrofsomin (Tc-TF) has been shown to be useful in identifying several types of tumors, such as breast, lung, and thyroid cancers. There was no report in the literature for Tc-TF uptake in hepatocellular carcinoma (HCC). The aim of this study was to evaluate the usefulness of Tc-TF liver imaging to detect HCC and investigate the relationship between Tc-TF liver imaging findings and P-glycoprotein (Pgp) and multidrug resistance associated protein (MRP) expression. Before any therapy, 22 patients with HCC were enrolled in this study. Tc-TF liver images were performed l0 minutes after intravenous injection of 20mCi Tc-TF. All patients had liver biopsy or surgery within l week after Tc-TF liver imaging. Immunohistochemical study of the biopsy or resected HCC specimens was performed using anti-human Pgp and MRP antibodies. Twenty of the 22 (90.9%) patients showed negative Tc-TF liver imaging results without significant Tc-TF uptake in HCC, whereas only the remaining 2 (9.1%) patients showed positive Tc-TF liver imaging results with significant Tc-TF uptake in HCC. Positive Pgp expression was observed in 13 of 20 patients with negative Tc-TF liver imaging results, whereas positive MRP expression was observed in 6 of the remaining 7 patients with negative both Tc-TF liver imaging results and Pgp expression. However, negative Pgp expression but positive MRP expression was observed in all of the remaining 2 patients with positive Tc-TF liver imaging results. The correlation between Tc-TF liver imaging findings and Pgp expression was significant and better than between Tc-TF liver imaging findings and MRP expression. Pgp or MRP expression in HCC may induce no significant Tc-TF uptake in HCC resulting in negative Tc-TF liver imaging findings. Therefore, Tc-TF liver imaging is potential to be a non-invasive method to predict Pgp or MRP expression in HCC. However, further studies with a larger series of patients and longer follow-up time are necessary to confirm

  17. Evaluation of image quality and radiation dose by adaptive statistical iterative reconstruction technique level for chest CT examination.

    Science.gov (United States)

    Hong, Sun Suk; Lee, Jong-Woong; Seo, Jeong Beom; Jung, Jae-Eun; Choi, Jiwon; Kweon, Dae Cheol

    2013-12-01

    The purpose of this research is to determine the adaptive statistical iterative reconstruction (ASIR) level that enables optimal image quality and dose reduction in the chest computed tomography (CT) protocol with ASIR. A chest phantom with 0-50 % ASIR levels was scanned and then noise power spectrum (NPS), signal and noise and the degree of distortion of peak signal-to-noise ratio (PSNR) and the root-mean-square error (RMSE) were measured. In addition, the objectivity of the experiment was measured using the American College of Radiology (ACR) phantom. Moreover, on a qualitative basis, five lesions' resolution, latitude and distortion degree of chest phantom and their compiled statistics were evaluated. The NPS value decreased as the frequency increased. The lowest noise and deviation were at the 20 % ASIR level, mean 126.15 ± 22.21. As a result of the degree of distortion, signal-to-noise ratio and PSNR at 20 % ASIR level were at the highest value as 31.0 and 41.52. However, maximum absolute error and RMSE showed the lowest deviation value as 11.2 and 16. In the ACR phantom study, all ASIR levels were within acceptable allowance of guidelines. The 20 % ASIR level performed best in qualitative evaluation at five lesions of chest phantom as resolution score 4.3, latitude 3.47 and the degree of distortion 4.25. The 20 % ASIR level was proved to be the best in all experiments, noise, distortion evaluation using ImageJ and qualitative evaluation of five lesions of a chest phantom. Therefore, optimal images as well as reduce radiation dose would be acquired when 20 % ASIR level in thoracic CT is applied.

  18. Radiological diagnosis of chest wall tuberculosis: CT versus chest radiograph

    International Nuclear Information System (INIS)

    Liu Fugeng; Pan Jishu; Chen Qihang; Zhou Cheng; Yu Jingying; Tang Dairong

    2006-01-01

    Objective: To evaluate the role of CT or Chest radiograph in diagnosis of chest wall tuberculosis. Methods: The study population included 21 patients with chest wall tuberculosis confirmed by operation or biopsy. Chest radiograph and plain CT were performed in all eases, while enhanced CT in 9 cases, and all images were reviewed by 2 radiologists. Results: Single soft tissue mass of the chest wall was detected in all cases on CT, but not on chest radiograph(χ 2 =42.000, P 2 =4.421, P<0.05). Conclusion: CT, especially enhanced CT scan is the first choice in the diagnosis of chest wall tuberculosis. (authors)

  19. Application of a simple phantom in assessing the effects of dose reduction on image quality in chest radiography

    International Nuclear Information System (INIS)

    Egbe, N.O.; Heaton, B.; Sharp, P.F.

    2010-01-01

    Purpose: Firstly, to evaluate a commercial chest phantom incorporating a quasi anthropomorphic insert by comparing exposure measurements on the phantom with those of actual patients and, secondly, to assess the value of the phantom for image quality and dose optimisation. Methods: In the first part of the study entrance surface doses (ESD), Beam transmission (BT), and optical density (OD) were obtained for 77 chest radiography patients and compared with measurements made from exposures of the phantom using the respective patient exposure factors from chest examination. Differences were assessed with a student t-test, while the Pearson's linear correlation coefficient was used to test for any linear relationship. The second part assessed the applicability of the phantom to image quality studies by investigating the effect, on the clarity and detectability of lung lesions made from gelatine, of reducing patient dose below current dose levels. Clarity of linear objects of different dimensions was also studied. Lesion detectability and clarity was assessed by four observers. The possibility of extending dose reduction below current dose levels (D ref ) was assessed from comparison of doses that produced statistically significant differences in image quality from D ref . Results: Results show that, with the exception of entrance doses and beam transmission through the diaphragm (P > 0.05), differences in OD and beam transmission between patients and phantom were statistically significant (P ref produced significant changes in both clarity and detectability. Conclusion: Within limits posed by the observed differences, the phantom can be applied to image quality studies in diagnostic radiology.

  20. Prognostic value of exercise thallium-201 imaging in patients presenting for evaluation of chest pain

    International Nuclear Information System (INIS)

    Brown, K.A.; Boucher, C.A.; Okada, R.D.; Guiney, T.E.; Newell, J.B.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Accurate prognostic information is important in determining optimal management of patients presenting for evaluation of chest pain. In this study, the ability of exercise thallium-201 myocardial imaging to predict future cardiac events (cardiovascular death or nonfatal myocardial infarction) was correlated with clinical, coronary and left ventricular angiographic and exercise electrocardiographic data in 139 consecutive, nonsurgically managed patients followed-up over a 3 to 5 year period (mean follow-up, 3.7 +/- 0.9), using a logistic regression analysis. Among patients without prior myocardial infarction (100 of 139), the number of myocardial segments with transient thallium-201 defects was the only statistically significant predictor of future cardiac events when all patient variables were evaluated. Among patients with myocardial infarction before evaluation (39 of 139), angiographic ejection fraction was the only significant predictor of future cardiac events when all variables were considered. This study suggests an approach to evaluate the risk of future cardiac events in patients with possible ischemic heart disease

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... abnormalities where Chest CT is a preferred imaging test. MR imaging can assess blood flow without risking ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... etc.). top of page What are some common uses of the procedure? MR imaging of the chest ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  4. Correlation between the signal-to-noise ratio improvement factor (KSNR) and clinical image quality for chest imaging with a computed radiography system

    International Nuclear Information System (INIS)

    Moore, C S; Wood, T J; Saunderson, J R; Beavis, A W

    2015-01-01

    This work assessed the appropriateness of the signal-to-noise ratio improvement factor (K SNR ) as a metric for the optimisation of computed radiography (CR) of the chest. The results of a previous study in which four experienced image evaluators graded computer simulated chest images using a visual grading analysis scoring (VGAS) scheme to quantify the benefit of using an anti-scatter grid were used for the clinical image quality measurement (number of simulated patients  =  80). The K SNR was used to calculate the improvement in physical image quality measured in a physical chest phantom. K SNR correlation with VGAS was assessed as a function of chest region (lung, spine and diaphragm/retrodiaphragm), and as a function of x-ray tube voltage in a given chest region. The correlation of the latter was determined by the Pearson correlation coefficient. VGAS and K SNR image quality metrics demonstrated no correlation in the lung region but did show correlation in the spine and diaphragm/retrodiaphragmatic regions. However, there was no correlation as a function of tube voltage in any region; a Pearson correlation coefficient (R) of  −0.93 (p  =  0.015) was found for lung, a coefficient (R) of  −0.95 (p  =  0.46) was found for spine, and a coefficient (R) of  −0.85 (p  =  0.015) was found for diaphragm. All demonstrate strong negative correlations indicating conflicting results, i.e. K SNR increases with tube voltage but VGAS decreases. Medical physicists should use the K SNR metric with caution when assessing any potential improvement in clinical chest image quality when introducing an anti-scatter grid for CR imaging, especially in the lung region. This metric may also be a limited descriptor of clinical chest image quality as a function of tube voltage when a grid is used routinely. (paper)

  5. Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain

    International Nuclear Information System (INIS)

    Erdogan, Zeynep; Silov, Güler; Özdal, Aysegül; Turhal, Özgül

    2013-01-01

    Myocardial perfusion imaging (MPI) with technetium-99m sestamibi ( 99m Tc MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of 99m Tc MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. (author)

  6. The study on the image quality and patient exposure dose of chest radiography in Korea

    International Nuclear Information System (INIS)

    Lee, Sun Sook; Huh, Joon

    1995-01-01

    Recently, general radiography became to variety because of the continuous development of Inverter type generator and ortho chromatic system. Therefore, we must re-evaluate about patient exposure dose and image quality. I studied about chest radiography which has frequency among general radiography being used during FEB. to AUG., 1994 over 151 medical facilities from medical facilities that are located in Seoul area. The result obtained were as follows; 1) The rectification method of the generator were employing mainly single phase full wave in 82.8 %, three phase full wave in 11.26 % and Inverter type in 4.64 % and condenser type is 1.32 %. 2) Exposure kV was used below 80 kV in most medical facilities and 21.8 % of the medical facilities was using high tube voltage higher than 120 kV. 3) The exposure time was used below the 0.05 sec in 28.4 %, in 29.8 % of the medical facilities used above 0.1 sec. 4) The usage frequency of the added filter is 15.3 %, and among them compound filter was used only 4 %. 5) Rare earth screen was used in 37.7 %. 6) The average skin entrance dose was 0.25 mSv, the range of dose is 0.05∼0.79 mSv in each medical facilities. 7) The average density of the lung field is 1.76, 0.49 in lung side, 0.30 in mediastinum and 0.37 in heart shadow. Therefore it is required to improve all of these for increasing image quality and reducing patient exposure dose as soon as possible

  7. Computed radiography versus mobile direct radiography for bedside chest radiographs: Impact of dose on image quality and reader agreement

    International Nuclear Information System (INIS)

    De Boo, D.W.; Weber, M.; Deurloo, E.E.; Streekstra, G.J.; Freling, N.J.; Dongelmans, D.A.; Schaefer-Prokop, C.M.

    2011-01-01

    Aim: To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Methods and materials: Three groups of age-, weight- and disease-matched ICU patients (n = 114 patients; 50 CXR per acquisition technique) underwent clinically indicated bedside CXR obtained with either CR (single read-out powder plates) or mobile DR (GOS-TFT detectors) at identical or 50% reduced dose (DR 50% ). Delineation of anatomic structures and devices used for patient monitoring, overall image quality and disease were scored by four readers. In 12 patients pairs of follow-up CR and DR images were available, and in 15 patients pairs of CR and DR 50% images were available. In these pairs the overall image quality was also compared side-by-side. Results: Delineation of anatomy in the mediastinum was scored better with DR or DR 50% than with CR. Devices used for patient monitoring were seen best with DR, with DR 50% being superior to CR. In the side-by-side comparison, the overall image quality of DR and DR 50% was rated better than CR in 96% (46/48) and 87% (52/60), respectively. Inter-observer agreement for the assessment of pathology was fair for CR and DR 50% (κ = 0.33 and κ = 0.39, respectively) and moderate for DR (κ = 0.48). Conclusion: Mobile DR units offer better image quality than CR for bedside chest radiography and allow for 50% dose reduction. Inter-observer agreement increases with image quality and is superior with DR, while DR 50% and CR are comparable.

  8. Evaluation of a new system for chest tomosynthesis: aspects of image quality of different protocols determined using an anthropomorphic phantom

    Science.gov (United States)

    Sundin, A; Aspelin, P; Båth, M; Nyrén, S

    2015-01-01

    Objective: To compare the image quality obtained with the different protocols in a new chest digital tomosynthesis (DTS) system. Methods: A chest phantom was imaged with chest X-ray equipment with DTS. 10 protocols were used, and for each protocol, nine acquisitions were performed. Four observers visually rated the quality of the reconstructed section images according to pre-defined quality criteria in four different classes. The data were analysed with visual grading characteristics (VGC) analysis, using the vendor-recommended protocol [12-s acquisition time, source-to-image distance (SID) 180 cm] as reference, and the area under the VGC curve (AUCVGC) was determined for each protocol and class of criteria. Results: Protocols with a smaller swing angle resulted in a lower image quality for the classes of criteria “disturbance” and “homogeneity in nodule” but a higher image quality for the class “structure”. The class “demarcation” showed little dependency on the swing angle. All protocols but one (6.3 s, SID 130 cm) obtained an AUCVGC significantly <0.5 (indicating lower quality than reference) for at least one class of criteria. Conclusion: The study indicates that the DTS protocol with 6.3 s yields image quality similar to that obtained with the vendor-recommended protocol (12 s) but with the clinically important advantage for patients with respiratory impairment of a shorter acquisition time. Advances in knowledge: The study demonstrates that the image quality may be strongly affected by the choice of protocol and that the vendor-recommended protocol may not be optimal. PMID:26118300

  9. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children

    International Nuclear Information System (INIS)

    Yoon, Haesung; Kim, Myung-Joon; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung; Yoon, Choon-Sik; Choi, Jiin

    2015-01-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique. (orig.)

  10. Selective common and uncommon imaging manifestations of blunt nonaortic chest trauma: when time is of the essence.

    Science.gov (United States)

    Altoos, Rola; Carr, Robert; Chung, Jonathan; Stern, Eric; Nevrekar, Dipti

    2015-01-01

    This is a pictorial essay in which we review and illustrate a variety of thoracic injuries related to blunt trauma. Non-aortic blunt thoracic trauma can be divided anatomically into injuries of the chest wall, lungs, pleura, mediastinum, and diaphragm. Some injuries involve more than one anatomic compartment, and multiple injuries commonly coexist. This article provides common imaging findings and discussion of both common and uncommon but critical thoracic injuries encountered. Published by Elsevier Inc.

  11. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Haesung; Kim, Myung-Joon; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Choi, Jiin [Yonsei University College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2015-03-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique. (orig.)

  12. Optimization of exposure parameters for pediatric chest x-ray imaging

    Science.gov (United States)

    Park, Hye-Suk; Kim, Ye-Seul; Kim, Hee-Joung

    2012-03-01

    The pediatric patients are more susceptible to the effects of ionizing radiation than adults. Pediatric patients are smaller, more radiosensitive than adult patients and many cannot stand unassisted. Their characteristics affect the method of imaging projection and how dose is optimized. The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kV in 10 kV increments at the focus-to-detector distance of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at same effective dose. The results showed that the eDQE was largest at 60 kVp without and with an anti-scatter grid. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing focus-to-detector distance because of the greater effective modulation transfer function (eMTF) with the lower focal spot blurring. In conclusion, for pediatric patients, the amount of scattered radiation is less, and the amount of grid attenuation increased unnecessary radiation dose.

  13. Semi-automated measurements of heart-to-mediastinum ratio on 123I-MIBG myocardial scintigrams by using image fusion method with chest X-ray images

    Science.gov (United States)

    Kawai, Ryosuke; Hara, Takeshi; Katafuchi, Tetsuro; Ishihara, Tadahiko; Zhou, Xiangrong; Muramatsu, Chisako; Abe, Yoshiteru; Fujita, Hiroshi

    2015-03-01

    MIBG (iodine-123-meta-iodobenzylguanidine) is a radioactive medicine that is used to help diagnose not only myocardial diseases but also Parkinson's diseases (PD) and dementia with Lewy Bodies (DLB). The difficulty of the segmentation around the myocardium often reduces the consistency of measurement results. One of the most common measurement methods is the ratio of the uptake values of the heart to mediastinum (H/M). This ratio will be a stable independent of the operators when the uptake value in the myocardium region is clearly higher than that in background, however, it will be unreliable indices when the myocardium region is unclear because of the low uptake values. This study aims to develop a new measurement method by using the image fusion of three modalities of MIBG scintigrams, 201-Tl scintigrams, and chest radiograms, to increase the reliability of the H/M measurement results. Our automated method consists of the following steps: (1) construct left ventricular (LV) map from 201-Tl myocardium image database, (2) determine heart region in chest radiograms, (3) determine mediastinum region in chest radiograms, (4) perform image fusion of chest radiograms and MIBG scintigrams, and 5) perform H/M measurements on MIBG scintigrams by using the locations of heart and mediastinum determined on the chest radiograms. We collected 165 cases with 201-Tl scintigrams and chest radiograms to construct the LV map. Another 65 cases with MIBG scintigrams and chest radiograms were also collected for the measurements. Four radiological technologists (RTs) manually measured the H/M in the MIBG images. We compared the four RTs' results with our computer outputs by using Pearson's correlation, the Bland-Altman method, and the equivalency test method. As a result, the correlations of the H/M between four the RTs and the computer were 0.85 to 0.88. We confirmed systematic errors between the four RTs and the computer as well as among the four RTs. The variation range of the H

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... chest is performed to: assess abnormal masses, including cancer of the lungs or other tissues, which either cannot be assessed ... in diagnosing a broad range of conditions, including cancer, heart and ... tissues, except for lung abnormalities where Chest CT is a preferred imaging ...

  15. Study of two novel large-field-of-view image intensifiers versus conventional chest radiography with use of FROC methods and simulated pulmonary nodules

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Van Waes, P.F.G.M.; Puylaert, C.B.A.J.

    1989-01-01

    Two novel large-field-of-view image intensifier (LFOV 1.1) tubes have been introduced whose image area makes them suitable for chest imaging. Both modalities present a 100-mm hard-copy image to the radiologist. A pulmonary nodule performance experiment was done to compare the diagnostic accuracy of these tubes with conventional full-size chest images. The data were analyzed with the maximum-likelihood FROCFIT program. The relative ranking in terms of decreasing A1 values was TLX, Siemens 43-cm mode, conventional radiography, and Siemens 57-cm mode

  16. New chromatographic systems for the quality control determination of 99Tcm-tetrofosmin

    International Nuclear Information System (INIS)

    Penglis, S.; Tsopelas, C.

    1999-01-01

    Full text: The manufacturer's method for assessing the radiochemical purity (RCP) of 99 Tc m -tetrofosmin requires the use of a volatile solvent system on silica gel impregnated thin layer chromatography strips, and is a time-consuming procedure (> 15 minutes). A rapid quality control procedure for this product has already been proposed which utilizes miniature Whatman 1 paper strips with ethyl acetate as the mobile phase, where 99 Tc m -tetrofosmin appears at the solvent front (R f 0.9). In our laboratory, this procedure was found to be unreliable, prompting us to develop two new and improved methods to successfully determine the % RCP of 99 Tc m -tetrofosmin. These include: (1) an Amprep anion exchange cartridge with absolute ethanol as the mobile phase; and (2) a miniature Whatman 17 strip with ethyl acetate:acetone [1:9] as the mobile phase. 99 Tc m -tetrofosmin elutes with the solvent, and 99 Tc m O 2 plus 99 Tc m O 4 -remain on the cartridge for the cartridge method. 99 Tc m -tetrofosmin moves with the solvent front (Rf 0.8) and the other 99 Tc m -impurities remain at the origin for the Whatman paper method. The % RCP of 99 Tc m -tetrofosmin (n = 8) by the manufacturer's method was 96.5 ± 1.5%, as compared to the cartridge method (98.0 ± 0.9%) and Whatman paper method (97.3 ± 0.9%) at 0-2 h post-reconstitution. The quality control determinations gave a result in 3 or 5 min for the cartridge or Whatman paper methods respectively. These methods can be used successfully in a dose calibrator for counting, particularly if the total counts are > 1.5 MBq. These new methods were found to be highly reproducible, convenient and rapid for the routine analysis of 99 Tc m -tetrofosmin preparations

  17. Imaging of non-cardiac, non-traumatic causes of acute chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Kienzl, Daniela, E-mail: daniela.kienzl@meduniwien.ac.at [Department of Radiology, Medical University of Vienna (Austria); Prosch, Helmut; Töpker, Michael; Herold, Christian [Department of Radiology, Medical University of Vienna (Austria)

    2012-12-15

    Non-traumatic chest pain is a common symptom in patients who present in the emergency department. From a clinical point of view, it is important to differentiate cardiac chest pain from non-cardiac chest pain (NCCP). Among the plethora of potential causes of NCCP, life-threatening diseases, such as aortic dissection, pulmonary embolism, tension pneumothorax, and esophageal rupture, must be differentiated from non-life threatening causes. The majority of NCCP, however, is reported to be benign in nature. The presentation of pain plays an important role in narrowing the differential diagnosis and initiating further diagnostic management and treatment. As the benign causes tend to recur, and may lead to patient anxiety and great costs, a meticulous evaluation of the patient is necessary to diagnose the underlying disorder or disease.

  18. Development and image quality assessment of a contrast-enhancement algorithm for display of digital chest radiographs

    International Nuclear Information System (INIS)

    Rehm, K.

    1992-01-01

    This dissertation presents a contrast-enhancement algorithm Artifact-Suppressed Adaptive Histogram Equalization (ASAHE). This algorithm was developed as part of a larger effort to replace the film radiographs currently used in radiology departments with digital images. Among the expected benefits of digital radiology are improved image management and greater diagnostic accuracy. Film radiographs record X-ray transmission data at high spatial resolution, and a wide dynamic range of signal. Current digital radiography systems record an image at reduced spatial resolution and with coarse sampling of the available dynamic range. These reductions have a negative impact on diagnostic accuracy. The contrast-enhancement algorithm presented in this dissertation is designed to boost diagnostic accuracy of radiologists using digital images. The ASAHE algorithm is an extension of an earlier technique called Adaptive Histogram Equalization (AHE). The AHE algorithm is unsuitable for chest radiographs because it over-enhances noise, and introduces boundary artifacts. The modifications incorporated in ASAHE suppress the artifacts and allow processing of chest radiographs. This dissertation describes the psychophysical methods used to evaluate the effects of processing algorithms on human observer performance. An experiment conducted with anthropomorphic phantoms and simulated nodules showed the ASAHE algorithm to be superior for human detection of nodules when compared to a computed radiography system's algorithm that is in current use. An experiment conducted using clinical images demonstrating pneumothoraces (partial lung collapse) indicated no difference in human observer accuracy when ASAHE images were compared to computed radiography images, but greater ease of diagnosis when ASAHE images were used. These results provide evidence to suggest that Artifact-Suppressed Adaptive Histogram Equalization can be effective in increasing diagnostic accuracy and efficiency

  19. Experimental article – Maintaining image quality for paediatric chest CTs while lowering dose : FBP versus SAFIRE

    NARCIS (Netherlands)

    Borgea, Synnøve; Campbell, Nina; Gomes, Ana; Raszkowskia, Aysha M.; Rook, Jan Willem; Sanderud, Audun; Vallinga, Anique; Buissink, Carst; Vouillamoze, Audrey

    2015-01-01

    Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children. This research concerns chest CT examinations on paediatric patients. The purpose of

  20. Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography

    International Nuclear Information System (INIS)

    Boos, Johannes; Kroepil, Patric; Klee, Dirk; Heusch, Philipp; Schimmoeller, Lars; Schaper, Joerg; Antoch, Gerald; Lanzman, Rotem S.

    2014-01-01

    Organ-specific dose reduction significantly reduces the radiation exposure of radiosensitive organs. The purpose of this study was to assess the impact of a novel organ-specific dose reduction algorithm on image quality of pediatric chest CT. We included 28 children (mean age 10.9 ± 4.8 years, range 3-18 years) who had contrast-enhanced chest CT on a 128-row scanner. CT was performed at 100 kV using automated tube current modulation and a novel organ-specific dose-reduction algorithm (XCare trademark; Siemens, Forchheim, Germany). Seven children had a previous chest CT performed on a 64-row scanner at 100 kV without organ-specific dose reduction. Subjective image quality was assessed using a five-point scale (1-not diagnostic; 5-excellent). Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed in the descending aorta. Overall mean subjective image quality was 4.1 ± 0.6. In the subgroup of the seven children examined both with and without organ-specific dose reduction, subjective image quality was comparable (score 4.4 ± 0.5 with organ-specific dose reduction vs. 4.4 ± 0.7 without it; P > 0.05). There was no significant difference in mean signal-to-noise ratio and contrast-to-noise ratio with organ-specific dose reduction (38.3 ± 10.1 and 28.5 ± 8.7, respectively) and without the reduction (35.5 ± 8.5 and 26.5 ± 7.8, respectively) (P > 0.05). Volume computed tomography dose index (CTDI vol ) and size-specific dose estimates did not differ significantly between acquisitions with the organ-specific dose reduction (1.7 ± 0.8 mGy) and without the reduction (1.7 ± 0.8 mGy) (P > 0.05). Organ-specific dose reduction does not have an impact on image quality of pediatric chest CT and can therefore be used in clinical practice to reduce radiation dose of radiosensitive organs such as breast and thyroid gland. (orig.)

  1. Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism.

    Science.gov (United States)

    Sommerauer, Michael; Graf, Carmen; Schäfer, Niklaus; Huber, Gerhard; Schneider, Paul; Wüthrich, Rudolf; Schmid, Christoph; Steinert, Hans

    2015-01-01

    Despite recommendations for 99mTc-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope 99mTc-tetrofosmin and 123I sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes. Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed. In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89 ± 46 vs. 129 ± 41 minutes, p = 0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions. Dual-isotope SPECT with 99mTc-tetrofosmin and 123I sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.

  2. Potential clinical impact of advanced imaging and computer-aided diagnosis in chest radiology: importance of radiologist's role and successful observer study.

    Science.gov (United States)

    Li, Feng

    2015-07-01

    This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. MRI of the chest gives detailed pictures ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Chest? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Chest? High-quality images are assured only if you are able ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... determine the presence of certain diseases. The images can then be examined on a computer monitor, transmitted ... of the chest cavity (arteries and veins). MRA can also demonstrate an abnormal ballooning out of the ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... etc.). top of page What are some common uses of the procedure? MR imaging of the chest ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... around the heart) disease. characterize mediastinal or pleural lesions seen by other imaging modalities, such as chest ... ports artificial limbs or metallic joint prostheses implanted nerve stimulators metal pins, screws, plates, stents or surgical ...

  10. Assessment of coronary flow reserve by sestamibi imaging in patients with typical chest pain and normal coronary arteries

    International Nuclear Information System (INIS)

    Storto, Giovanni; Sorrentino, Anna R.; Pellegrino, Teresa; Liuzzi, Raffaele; Cuocolo, Alberto; Petretta, Mario

    2007-01-01

    We assessed coronary flow reserve (CFR) by sestamibi imaging in patients with typical chest pain, positive exercise stress test and normal coronary vessels. Thirty-five patients with typical chest pain and normal angiogram and 12 control subjects with atypical chest pain underwent dipyridamole/rest 99m Tc-sestamibi imaging. Myocardial blood flow (MBF) was estimated by measuring first transit counts in the pulmonary artery and myocardial counts from SPECT images. Estimated CFR was expressed as the ratio of stress to rest MBF. Rest MBF and CFR were corrected for rate-pressure product (RPP) and expressed as normalised MBF (MBF n ) and normalised CFR (CFR n ). Coronary vascular resistances (CVR) were calculated as the ratio between mean arterial pressure and estimated MBF. At rest, estimated MBF and MBF n were lower in controls than in patients (0.98 ± 0.4 vs 1.30 ± 0.3 counts/pixel/s and 1.14 ± 0.5 vs 1.64 ± 0.6 counts/pixel/s, respectively, both p n was still higher in controls than in patients (2.1 ± 0.5 vs 1.29 ± 0.5, p < 0.0001). At baseline, CVR values were lower (p < 0.01) in patients than in controls. Dipyridamole-induced changes in CVR were greater (p < 0.0001) in controls (-63%) than in patients (-35%). In the overall study population, a significant correlation between dipyridamole-induced changes in CVR and CFR was observed (r = -0.88, p < 0.0001). SPECT might represent a useful non-invasive method for assessing coronary vascular function in patients with angina and a normal coronary angiogram. (orig.)

  11. Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT

    International Nuclear Information System (INIS)

    Hwang, Hye Jeon; Seo, Joon Beom; Lee, Jin Seong; Song, Jae Woo; Lee, Hyun Joo; Lim, Chae Hun; Kim, Song Soo

    2012-01-01

    To determine whether the image quality (IQ) is improved with iterative reconstruction in image space (IRIS), and whether IRIS can be used for radiation reduction in chest CT. Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying a dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from a single tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Objective noise was measured. The subjective IQ was evaluated by radiologists for the followings: noise, contrast and sharpness of mediastinum and lung. Objective noise was significantly lower in H-IRIS than in F-FBP (p < 0.01). In both SDCT and LDCT, the IQ scores were highest in F-IRIS, followed by F-FBP, H-IRIS and H-FBP, except those for sharpness of mediastinum, which tended to be higher in FBP. When comparing CT images between the same dose and different reconstruction (F-IRIS/F-FBP and H-IRIS/H-FBP) algorithms, scores tended to be higher in IRIS than in FBP, being more distinct in half-dose images. However, despite the use of IRIS, the scores were lower in H-IRIS than in F-FBP. IRIS generally helps improve the IQ, being more distinct at the reduced radiation. However, reduced radiation by half results in IQ decrease even when using IRIS in chest CT.

  12. Visual grading analysis of digital neonatal chest phantom X-ray images: Impact of detector type, dose and image processing on image quality.

    Science.gov (United States)

    Smet, M H; Breysem, L; Mussen, E; Bosmans, H; Marshall, N W; Cockmartin, L

    2018-07-01

    To evaluate the impact of digital detector, dose level and post-processing on neonatal chest phantom X-ray image quality (IQ). A neonatal phantom was imaged using four different detectors: a CR powder phosphor (PIP), a CR needle phosphor (NIP) and two wireless CsI DR detectors (DXD and DRX). Five different dose levels were studied for each detector and two post-processing algorithms evaluated for each vendor. Three paediatric radiologists scored the images using European quality criteria plus additional questions on vascular lines, noise and disease simulation. Visual grading characteristics and ordinal regression statistics were used to evaluate the effect of detector type, post-processing and dose on VGA score (VGAS). No significant differences were found between the NIP, DXD and CRX detectors (p>0.05) whereas the PIP detector had significantly lower VGAS (pProcessing did not influence VGAS (p=0.819). Increasing dose resulted in significantly higher VGAS (plevels but not image post-processing changes. VGA showed a DAK/image value above which perceived IQ did not improve, potentially useful for commissioning. • A VGA study detects IQ differences between detectors and dose levels. • The NIP detector matched the VGAS of the CsI DR detectors. • VGA data are useful in setting initial detector air kerma level. • Differences in NNPS were consistent with changes in VGAS.

  13. Assessment of Takotsubo (ampulla) cardiomyopathy using 99mTc-tetrofosmin myocardial SPECT. Comparison with acute coronary syndrome

    International Nuclear Information System (INIS)

    Ito, Kazuki; Katoh, Shuji

    2003-01-01

    We assessed Takotsubo (ampulla) cardiomyopathy compared with acute coronary syndrome (ACS) using two-dimensional echocardiography and 99m Tc-tetrofosmin myocardial SPECT. We examined 10 patients with Takotsubo cardiomyopathy and 16 with ACS at the time of emergency admission (acute phase), at three to nine days after the attack (subacute phase) and at one month after the attack (chronic phase). The left ventricle was divided into nine regions on echocardiograms and SPECT images, and the degree of abnormalities in each region was scored in five grades from normal (0) to severely abnormal (4). Coronary angiography revealed total or subtotal occlusion in patients with ACS but no stenotic legions in those with Takotsubo cardiomyopathy. The amount of ST segment elevation (mm) was 7.9±3.4 in patients with Takotsubo cardiomyopathy and 7.3±3.7 in those with ACS (N.S.). Abnormal wall motion scores on echocardiograms were 13.8±4.4, 4.4±3.8 and 1.8±2.3 during the acute, subacute and chronic phases in patients with Takotsubo cardiomyopathy, and 13.9±4.0, 11.7±3.7, 7.6±4.2, respectively in patients with ACS. The value of MB fraction of creatine phosphokinase (IU/l) was 34±23 in patients with Takotsubo cardiomyopathy and 326±98 in those with ACS (p 99m Tc-tetrofosmin myocardial SPECT were 11.4±3.2, 3.2±3.3 and 0.7±1.1 during the acute, subacute and chronic phases respectively, in patients with Takotsubo cardiomyopathy, and 15.8±4.1, 13.5±4.4, 8.2±4.4, respectively, in those with ACS. The numbers of myocardial segments that did not uptake 99m Tc-tetrofosmin during the acute phase were 0.5±0.8 and 3.6±2.8 in patients with Takotsubo cardiomyopathy and ACS, respectively. Impaired coronary microcirculation might be a causative mechanism of Takotsubo cardiomyopathy. (author)

  14. Lesion detection performance: comparative analysis of low-dose CT data of the chest on two hybrid imaging systems.

    Science.gov (United States)

    Jessop, Maryam; Thompson, John D; Coward, Joanne; Sanderud, Audun; Jorge, José; de Groot, Martijn; Lança, Luís; Hogg, Peter

    2015-03-01

    Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). JAFROC analysis showed a significant difference (P detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified. © 2015 by the Society of Nuclear Medicine and Molecular Imaging

  15. Imaging of tuberculosis - experience from 503 patients. 1. Tuberculosis of the chest

    International Nuclear Information System (INIS)

    Nyman, R.S.; Brismar, J.; Hugosson, C.; Larsson, S.G.; Lundstedt, C.

    1996-01-01

    Purpose: To give an overview of 503 patients with tuberculosis (TB) and to describe the radiologic findings of chest TB. Material and Methods: A total of 503 patients with proven TB were reviewed; 266 had chest involvement. Results: Lung lesions were demonstrated in 214 patients. Infiltrates in the basal parts of the lungs or pleural effusion were often primarily mistaken for viral or bacterial infections. Consolidations within the lungs and pleural thickening were sometimes indistinguishable from malignancy. Positive culture of the sputum without lung lesions was encountered in 12 cases. Enlarged mediastinal lymph nodes were demonstrated in 67 cases, 35 without lesions in the lungs. The lymphadenopathy could be extensive, and both clinically and radiologically indistinguishable from lymphoma. Conclusion: Due to the present increase in incidence of TB and the fact that TB can mimic many other conditions, it is important that both clinicians and radiologists have TB high on the list for differential diagnoses. (orig.)

  16. An analysis of the potential role of chest tomosynthesis in optimising imaging resources in thoracic radiology

    International Nuclear Information System (INIS)

    Petersson, Cecilia; Baath, Magnus; Vikgren, Jenny; Allansdotter Johnsson, Aase

    2016-01-01

    The aim of the study was to investigate the potential role of chest tomosynthesis (CTS) at a tertiary referral centre by exploring to what extent CTS could substitute chest radiography (CXR) and computed tomography (CT). The study comprised 1433 CXR, 523 CT and 216 CTS examinations performed 5 years after the introduction of CTS. For each examination, it was decided if CTS would have been appropriate instead of CXR (CXR cases), if CTS could have replaced the performed CT (CT cases) or if CT would have been performed had CTS not been available (CTS cases). It was judged that (a) CTS had been appropriate in 15 % of the CXR examinations, (b) CTS could have replaced additionally 7 % of the CT examinations and (c) CT would have been carried out in 63 % of the performed CTS examinations, had CTS not been available. In conclusion, the potential role for CTS to substitute other modalities during office hours at a tertiary referral centre may be in the order of 20 and 25 % of performed CXR and chest CT, respectively. (authors)

  17. AN ANALYSIS OF THE POTENTIAL ROLE OF CHEST TOMOSYNTHESIS IN OPTIMISING IMAGING RESOURCES IN THORACIC RADIOLOGY.

    Science.gov (United States)

    Petersson, Cecilia; Båth, Magnus; Vikgren, Jenny; Johnsson, Åse Allansdotter

    2016-06-01

    The aim of the study was to investigate the potential role of chest tomosynthesis (CTS) at a tertiary referral centre by exploring to what extent CTS could substitute chest radiography (CXR) and computed tomography (CT). The study comprised 1433 CXR, 523 CT and 216 CTS examinations performed 5 years after the introduction of CTS. For each examination, it was decided if CTS would have been appropriate instead of CXR (CXR cases), if CTS could have replaced the performed CT (CT cases) or if CT would have been performed had CTS not been available (CTS cases). It was judged that (a) CTS had been appropriate in 15 % of the CXR examinations, (b) CTS could have replaced additionally 7 % of the CT examinations and (c) CT would have been carried out in 63 % of the performed CTS examinations, had CTS not been available. In conclusion, the potential role for CTS to substitute other modalities during office hours at a tertiary referral centre may be in the order of 20 and 25 % of performed CXR and chest CT, respectively. © The Author 2016. Published by Oxford University Press.

  18. AN ANALYSIS OF THE POTENTIAL ROLE OF CHEST TOMOSYNTHESIS IN OPTIMISING IMAGING RESOURCES IN THORACIC RADIOLOGY

    Science.gov (United States)

    Petersson, Cecilia; Båth, Magnus; Vikgren, Jenny; Johnsson, Åse Allansdotter

    2016-01-01

    The aim of the study was to investigate the potential role of chest tomosynthesis (CTS) at a tertiary referral centre by exploring to what extent CTS could substitute chest radiography (CXR) and computed tomography (CT). The study comprised 1433 CXR, 523 CT and 216 CTS examinations performed 5 years after the introduction of CTS. For each examination, it was decided if CTS would have been appropriate instead of CXR (CXR cases), if CTS could have replaced the performed CT (CT cases) or if CT would have been performed had CTS not been available (CTS cases). It was judged that (a) CTS had been appropriate in 15 % of the CXR examinations, (b) CTS could have replaced additionally 7 % of the CT examinations and (c) CT would have been carried out in 63 % of the performed CTS examinations, had CTS not been available. In conclusion, the potential role for CTS to substitute other modalities during office hours at a tertiary referral centre may be in the order of 20 and 25 % of performed CXR and chest CT, respectively. PMID:26979807

  19. Chest imaging characteristics of hand-foot-mouth disease in children

    International Nuclear Information System (INIS)

    Ma Bo; Chen Ruigang; Dou Shewei; Zhu Xiaonian; Shi Dapeng

    2010-01-01

    Objective: To study radiological characteristics of hand-foot-mouth disease (HFMD) in children. Methods: The chest X-ray films of 1295 children patients of HFMD were analyzed, for the general X-ray manifestations and the evolution. Results: A total of 1427 films was obtained from all patients, in which 1203 cases were normal and 224 cases were abnormal. The interstitial changes characterized the abnormal group, mainly as increased and vague lung markings, increased hilar shadows (137 cases). The parenchyma changes appeared as patchy exudative shadows(49 cases). Short-term dynamic observation was applied in 62 cases, 38 cases pulmonary disease progression manifested as normal and the interstitial type changing into the parenchyma type and the mixed type, the localized type changing into the diffuse type. Conclusions: Most children patients of' HFMD showed normal chest films, while the abnormal patients were characterized by interstitial and parenchyma pulmonary edema. Serial chest X-ray examination and short-term dynamic observation were important to identify the severe cases and assess patients' condition. (authors)

  20. Predictors of image quality of coronary computed tomography in the acute care setting of patients with chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Bamberg, Fabian; Abbara, Suhny; Schlett, Christopher L.; Cury, Ricardo C.; Truong, Quynh A.; Rogers, Ian S. [Cardiac MR PET CT Program, Department of Radiology and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Nagurney, John T. [Department of Emergency Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Cardiac MR PET CT Program, Department of Radiology and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Cardiac MR PET CT Program, Department of Radiology and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)], E-mail: uhoffmann@partners.org

    2010-04-15

    Objective: We aimed to determine predictors of image quality in consecutive patients who underwent coronary computed tomography (CT) for the evaluation of acute chest pain. Method and materials: We prospectively enrolled patients who presented with chest pain to the emergency department. All subjects underwent contrast-enhanced 64-slice coronary multi-detector CT. Two experienced readers determined overall image quality on a per-patient basis and the prevalence and characteristics of non-evaluable coronary segments on a per-segment basis. Results: Among 378 subjects (143 women, age: 52.9 {+-} 11.8 years), 345 (91%) had acceptable overall image quality, while 33 (9%) had poor image quality or were unreadable. In adjusted analysis, patients with diabetes, hypertension and a higher heart rate during the scan were more likely to have exams graded as poor or unreadable (odds ratio [OR]: 2.94, p = 0.02; OR: 2.62, p = 0.03; OR: 1.43, p = 0.02; respectively). Of 6253 coronary segments, 257 (4%) were non-evaluable, most due to severe calcification in combination with motion (35%). The presence of non-evaluable coronary segments was associated with age (OR: 1.08 annually, 95%-confidence interval [CI]: 1.05-1.12, p < 0.001), baseline heart rate (OR: 1.35 per 10 beats/min, 95%-CI: 1.11-1.67, p = 0.003), diabetes, hypertension, and history of coronary artery disease (OR: 4.43, 95%-CI: 1.93-10.17, p < 0.001; OR: 2.27, 95-CI: 1.01-4.73, p = 0.03; OR: 5.12, 95%-CI: 2.0-13.06, p < 0.001; respectively). Conclusion: Coronary CT permits acceptable image quality in more than 90% of patients with chest pain. Patients with multiple risk factors are more likely to have impaired image quality or non-evaluable coronary segments. These patients may require careful patient preparation and optimization of CT scanning protocols.

  1. Effect of collateral circulation on myocardial protection in patients with acute myocardial infarction. Comparison of technetium-99m-tetrofosmin myocardial single photon emission computed tomography and coronary angiography

    International Nuclear Information System (INIS)

    Yoshida, Michi; Kondo, Makoto; Abe, Yoshiteru; Kubota, Tomoyuki; Matsuoka, Ryota; Araki, Makoto; Tanio, Hitoshi; Doyama, Kiyoshi

    2006-01-01

    Evaluation of myocardial blood flow from collateral vessels into the infarct area has been estimated by coronary angiography. In patients with acute myocardial infarction with Thrombolysis in Myocardial Infarction (TIMI) 0 flow, myocardial tracer uptake on single photon emission computed tomography (SPECT) images can predict the collateral blood flow in the infarct area if technetium (Tc)-99m-tetrofosmin was administered before recanalization. The present study investigated whether collateral blood flow evaluated by myocardial scintigraphy is a good predictor of myocardial salvage in patients with acute myocardial infarction. The study group consisted of 30 patients (mean age 65±14 years, 23 males, 7 females) with first acute myocardial infarction and coronary angiography evidence of total occlusion (TIMI 0) within 12 hr after the onset. All patients had one vessel disease related to infarction and TIMI 3 flow after percutaneous coronary intervention (PCI). Tc-99m-tetrofosmin was injected intravenously before the PCI. The regional severity score index (RSSI) was obtained from SPECT using the 17 segment method with the four-point scoring system. Myocardial viability was evaluated by the RSSI obtained from thallium-glucose-insulin infusion SPECT after 1 week and regional wall motion score index obtained from echocardiography during the chronic phase. The patients were divided into two groups according to the angiographic collateral finding. There were no differences in RSSI on thallium-glucose-insulin SPECT and regional wall motion score between the good collateral group (n=8) and poor collateral group (n=22). Myocardial Tc-99m-tetrofosmin RSSI was similar in these groups. On the other hand, the patients were divided according to Tc-99m-tetrofosmin scintigraphic evaluation before PCI. RSSI on thallium-glucose-insulin SPECT was significantly greater (0.7±0.5 vs 1.5±0.4, p<0.01) and regional wall motion score was significantly less (1.46±0.50 vs 2.08±0.78, p<0

  2. Comparison of Model Predictions of Image Quality with Results of Clinical Trials in Chest and Lumbar Spine Screen-film Imaging

    International Nuclear Information System (INIS)

    Sandborg, M.; McVey, G.; Dance, D.R.; Carlsson, G.A.

    2000-01-01

    The ability to predict image quality from known physical and technical parameters is a prerequisite for making successful dose optimisation. In this study, imaging systems have been simulated using a Monte Carlo model of the imaging systems. The model includes a voxelised human anatomy and quantifies image quality in terms of contrast and signal-to-noise ratio for 5-6 anatomical details included in the anatomy. The imaging systems used in clinical trials were simulated and the ranking of the systems by the model and radiologists compared. The model and the results of the trial for chest PA both show that using a high maximum optical density was significantly better than using a low one. The model predicts that a good system is characterised by a large dynamic range and a high contrast of the blood vessels in the retrocardiac area. The ranking by the radiologists and the model agreed for the lumbar spine AP. (author)

  3. The relationship between image quality and CT dose index of multi-slice low-dose chest CT

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Shao Jiang; Shi Jingyun; You Zhengqian; Li Shijun; Xue Yongming

    2003-01-01

    Objective: To explore the rationality and possibility of multi-slice low-dose CT scan in the examination of the chest. Methods: (1) X-ray dose index measurement: 120 kV tube voltage, 0.75 s rotation, 8 mm and 3 mm slice thickness, and the tube current setting of 115.0, 40.0, 25.0, and 7.5 mAs were employed in every section. The X-ray radiation dose was measured and compared statistically. (2) phantom measurement of homogeneity and noise: The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm sections, and every slice was scanned using tube current of 115.0, 40.0, 25.0, and 7.5 mAs. Five same regions of interest were measured on every image. The homogeneity and noise level of CT were appraised. (3) The multi-slice low-dose CT in patients: 30 patients with mass and 30 with patch shadow in the lung were selected randomly. The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm slice thickness. 115.0, 40.0, 25.0, 15.0, and 7.5 mAs tube current were employed in each same slice. Otherwise, 15 cases with helical scan were examined using 190, 150, 40, 25, and 15 mAs tube current. The reconstruction images of MIP, MPR, CVR, HRCT, 3D, CT virtual endoscopy, and variety of interval reconstruction were compared. (4) Evaluation of image quality: CT images were evaluated by four doctors using single-blind method, and 3 degrees including normal image, image with few artifact, and image with excessive artifact, were employed and analyzed statistically. Results: (1) The CT dose index with 115.0 mAs tube current exceeded those of 40.0, 25.0, and 7.5 mAs by about 60%, 70%, and 85%, respectively. (2) The phantom measurement showed that the lower of CT dose the lower of homogeneity, the lower of CT dose the higher of noise level. (3) Result of image quality evaluation: The percentage of the normal image had no significant difference between 8 and 3 mm in 115, 40, and 25 mAs (P>0.05). Conclusion: Multi-slice low-dose chest CT technology may protect the patients and guarantee the

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... bear denotes child-specific content. Related Articles and Media MR ... Images related to Magnetic Resonance Imaging (MRI) - Chest Sponsored ...

  5. Quantitation of pulmonary nodule's border structure by means of Fourier transform by using chest X-ray CT images

    International Nuclear Information System (INIS)

    Shikata, Hidenori; Masuyama, Hiroshi; Kido, Shoji

    1998-01-01

    In order to evaluate quantitatively the border structure of pulmonary nodules by using chest X-ray CT images, we investigated whether the sum of high-frequency elements of the power spectrum in a Fourier-transformed nodule's contour line becomes a valuable measure of the border structure of pulmonary nodules. We expect that this measure clearly reflects the radiologic characteristics of a nodule, that is, the contour line is clear or unclear in benign or malignant nodules, respectively. We evaluated and analyzed images statistically for 31 patients (15 benign, 16 malignant), and we were able to recognize a measurable difference between the benign and malignant cases. We conclude that we can evaluate the border structure of a nodule by our proposed measure, and that this measure is valuable for quantitative differential diagnosis. (author)

  6. Influence of 'optical illusion' on the detectability of pneumothorax in diagnosis for chest CT images. Substantiation by visual psychological simulation images

    International Nuclear Information System (INIS)

    Henmi, Shuichi

    2008-01-01

    Some cases have been reported in which an optical illusion of lightness perception influences the detectability in diagnosis of low-density hematoma in head CT images in addition to the visual impression of the photographic density of the brain. Therefore, in this study, the author attempted to compare the detectability in diagnosis for chest images with pneumothorax using visual subjective evaluation, and investigated the influence of optical illusion on that detectability in diagnosis. Results indicated that in the window setting of lung, on such an occasion when the low-absorption free space with pneumothorax forms a crescent or the reduced lung borders on the chest-wall, an optical illusion in which the visual impression on the difference of the film contrast between the lung and the low-absorption free space with pneumothorax was psychologically emphasized when contrast was observed. In all cases the detectability in diagnosis for original images with the white thorax and mediastinum was superior to virtual images. Further, in case of the virtual double window setting of lung, thorax, and mediastinum, under the influence of the difference in the radiological anatomy of thorax and mediastinum as a result of the grouping theories of lightness computation, an optical illusion different from the original images was observed. (author)

  7. Myocardial impairment detected by late gadolinium enhancement in hypertrophic cardiomyopathy: comparison with 99mTc-MIBI/tetrofosmin and 123I-BMIPP SPECT.

    Science.gov (United States)

    Hashimura, Hiromi; Kiso, Keisuke; Yamada, Naoaki; Kono, Atsushi; Morita, Yoshiaki; Fukushima, Kazuto; Higashi, Masahiro; Noguchi, Teruo; Ishibashi-Ueda, Hatsue; Naito, Hiroaki; Sugimura, Kazuro

    2013-06-17

    Myocardial fibrosis is considered to be an important factor in myocardial dysfunction and sudden cardiac death in hypertrophic cardiomyopathy (HCM). The purpose of this study was to compare myocardial fibrosis detected by late gadolinium enhancement (LGE) on cardiac MRI with myocardial perfusion and fatty acid metabolism assessed by single photon emission computed tomography in HCM. We retrospectively evaluated 20 consecutive HCM patients (female, 7; mean age, 53.4 years) who underwent LGE, technetium-99m methoxyisobutylisonitrile/tetrofosmin (99mTc-MIBI/tetrofosmin), and iodine-123 beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) imaging. We calculated the myocardium-to-lumen signal ratio (M/L) for LGE in 17 segments based on the American Heart Association statement. Scoring of 99mTc-MIBI/tetrofosmin (PI) and 123I-BMIPP (BM) was performed for each segment using a 5-point scale (0, normal; 4, highly decreased). Nineteen of 20 patients (95%) and 153 of 340 segments (45%) showed LGE. M/Ls were 0.42±0.16, 0.55±0.17, and 0.65±0.24 in PI0/BM0, PI0/BM1-4 and PI1-4/BM1-4, respectively. All M/Ls were significantly higher than that of a normal control (0.34±0.14) (pacid metabolism, and is more strongly associated with disorders of fatty acid metabolism than with perfusion abnormalities. M/L may be a useful indicator of disease severity.

  8. An analysis of line-drawings based upon automatically inferred grammar and its application to chest x-ray images

    International Nuclear Information System (INIS)

    Nakayama, Akira; Yoshida, Yuuji; Fukumura, Teruo

    1984-01-01

    There is a technique using inferring grammer as image- structure analyzing technique. This technique involves a few problems if it is applied to naturally obtained images, as the practical grammatical technique for two-dimensional image is not established. The authors developed a technique which solved the above problems for the main purpose of the automated structure analysis of naturally obtained image. The first half of this paper describes on the automatic inference of line drawing generation grammar and the line drawing analysis based on that automatic inference. The second half of the paper reports on the actual analysis. The proposed technique is that to extract object line drawings out of the line drawings containing noise. The technique was evaluated for its effectiveness with an example of extracting rib center lines out of thin line chest X-ray images having practical scale and complexity. In this example, the total number of characteristic points (ends, branch points and intersections) composing line drawings per one image was 377, and the total number of line segments composing line drawings was 566 on average per sheet. The extraction ratio was 86.6 % which seemed to be proper when the complexity of input line drawings was considered. Further, the result was compared with the identified rib center lines with the automatic screening system AISCR-V3 for comparison with the conventional processing technique, and it was satisfactory when the versatility of this method was considered. (Wakatsuki, Y.)

  9. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Matsunobu, Y; Shiotsuki, K [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Morishita, J [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, JP (Japan)

    2015-06-15

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body.

  10. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    International Nuclear Information System (INIS)

    Matsunobu, Y; Shiotsuki, K; Morishita, J

    2015-01-01

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body

  11. Adequacy of source to image receptor distance with chest postero-anterior projection in digital radiology system

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Young Cheol [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Lim, Cheong Hwan; Jung, Hong Ryang [Dept. of Radiology, Science, Hanseo University, Seosan (Korea, Republic of); You, In Gyu [Dept. of Radiology, Hallym University Hospital, Chuncheon (Korea, Republic of); Lee, Sang Ho [Dept. of Radiology, Science, Seonam University, Namwon (Korea, Republic of)

    2016-06-15

    The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7⁓3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6⁓2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6⁓8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6⁓8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

  12. Adequacy of source to image receptor distance with chest postero-anterior projection in digital radiology system

    International Nuclear Information System (INIS)

    Joo, Young Cheol; Lim, Cheong Hwan; Jung, Hong Ryang; You, In Gyu; Lee, Sang Ho

    2016-01-01

    The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7⁓3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6⁓2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6⁓8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6⁓8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment

  13. Effective high voltage at X-ray tube in hard X-ray chest imaging

    International Nuclear Information System (INIS)

    Klein, J.

    1987-01-01

    The FRG standard TGL 36 661 (March 1980) for synoptical chest pictures of large size in adults specifies the 120 kV voltage at the X-ray tube together with maximal, 100% use of the capacity of the tube (hard picture, short exposure time). By means of circular recording and by measuring the high voltage at the X-ray tube it was quantitatively shown that the effective voltage during exposure is (according to the exposure time and the attenuation phase of the generator) always lower than the set-up voltage of 120 kV. This phenomenon is the more marked the shorter the actual exposure time in comparison with the attenuation phase of the generator. The typical characteristic of a hard X-ray chest picture is thus not given only by the setting-up of voltage. The impact of the reduction in voltage is thus quantitatively shown also from the aspect of the radiation burden for the patient. (author). 7 figs., 8 refs

  14. Dense volumetric detection and segmentation of mediastinal lymph nodes in chest CT images

    Science.gov (United States)

    Oda, Hirohisa; Roth, Holger R.; Bhatia, Kanwal K.; Oda, Masahiro; Kitasaka, Takayuki; Iwano, Shingo; Homma, Hirotoshi; Takabatake, Hirotsugu; Mori, Masaki; Natori, Hiroshi; Schnabel, Julia A.; Mori, Kensaku

    2018-02-01

    We propose a novel mediastinal lymph node detection and segmentation method from chest CT volumes based on fully convolutional networks (FCNs). Most lymph node detection methods are based on filters for blob-like structures, which are not specific for lymph nodes. The 3D U-Net is a recent example of the state-of-the-art 3D FCNs. The 3D U-Net can be trained to learn appearances of lymph nodes in order to output lymph node likelihood maps on input CT volumes. However, it is prone to oversegmentation of each lymph node due to the strong data imbalance between lymph nodes and the remaining part of the CT volumes. To moderate the balance of sizes between the target classes, we train the 3D U-Net using not only lymph node annotations but also other anatomical structures (lungs, airways, aortic arches, and pulmonary arteries) that can be extracted robustly in an automated fashion. We applied the proposed method to 45 cases of contrast-enhanced chest CT volumes. Experimental results showed that 95.5% of lymph nodes were detected with 16.3 false positives per CT volume. The segmentation results showed that the proposed method can prevent oversegmentation, achieving an average Dice score of 52.3 +/- 23.1%, compared to the baseline method with 49.2 +/- 23.8%, respectively.

  15. Dynamic imaging in electrical impedance tomography of the human chest with online transition matrix identification.

    Science.gov (United States)

    Moura, Fernando Silva; Aya, Julio Cesar Ceballos; Fleury, Agenor Toledo; Amato, Marcelo Britto Passos; Lima, Raul Gonzalez

    2010-02-01

    One of the electrical impedance tomography objectives is to estimate the electrical resistivity distribution in a domain based only on electrical potential measurements at its boundary generated by an imposed electrical current distribution into the boundary. One of the methods used in dynamic estimation is the Kalman filter. In biomedical applications, the random walk model is frequently used as evolution model and, under this conditions, poor tracking ability of the extended Kalman filter (EKF) is achieved. An analytically developed evolution model is not feasible at this moment. The paper investigates the identification of the evolution model in parallel to the EKF and updating the evolution model with certain periodicity. The evolution model transition matrix is identified using the history of the estimated resistivity distribution obtained by a sensitivity matrix based algorithm and a Newton-Raphson algorithm. To numerically identify the linear evolution model, the Ibrahim time-domain method is used. The investigation is performed by numerical simulations of a domain with time-varying resistivity and by experimental data collected from the boundary of a human chest during normal breathing. The obtained dynamic resistivity values lie within the expected values for the tissues of a human chest. The EKF results suggest that the tracking ability is significantly improved with this approach.

  16. Stress Tests for Chest Pain: When You Need an Imaging Test -- and When You Don't

    Science.gov (United States)

    ... Resources Adult , Geriatric Stress Tests for Chest Pain Stress Tests for Chest Pain When you need an ... pain isn’t from heart disease. A cardiac stress test makes the heart work hard so your ...

  17. Chest Computed Tomographic Image Screening for Cystic Lung Diseases in Patients with Spontaneous Pneumothorax Is Cost Effective.

    Science.gov (United States)

    Gupta, Nishant; Langenderfer, Dale; McCormack, Francis X; Schauer, Daniel P; Eckman, Mark H

    2017-01-01

    Patients without a known history of lung disease presenting with a spontaneous pneumothorax are generally diagnosed as having primary spontaneous pneumothorax. However, occult diffuse cystic lung diseases such as Birt-Hogg-Dubé syndrome (BHD), lymphangioleiomyomatosis (LAM), and pulmonary Langerhans cell histiocytosis (PLCH) can also first present with a spontaneous pneumothorax, and their early identification by high-resolution computed tomographic (HRCT) chest imaging has implications for subsequent management. The objective of our study was to evaluate the cost-effectiveness of HRCT chest imaging to facilitate early diagnosis of LAM, BHD, and PLCH. We constructed a Markov state-transition model to assess the cost-effectiveness of screening HRCT to facilitate early diagnosis of diffuse cystic lung diseases in patients presenting with an apparent primary spontaneous pneumothorax. Baseline data for prevalence of BHD, LAM, and PLCH and rates of recurrent pneumothoraces in each of these diseases were derived from the literature. Costs were extracted from 2014 Medicare data. We compared a strategy of HRCT screening followed by pleurodesis in patients with LAM, BHD, or PLCH versus conventional management with no HRCT screening. In our base case analysis, screening for the presence of BHD, LAM, or PLCH in patients presenting with a spontaneous pneumothorax was cost effective, with a marginal cost-effectiveness ratio of $1,427 per quality-adjusted life-year gained. Sensitivity analysis showed that screening HRCT remained cost effective for diffuse cystic lung diseases prevalence as low as 0.01%. HRCT image screening for BHD, LAM, and PLCH in patients with apparent primary spontaneous pneumothorax is cost effective. Clinicians should consider performing a screening HRCT in patients presenting with apparent primary spontaneous pneumothorax.

  18. Assessment of coronary flow reserve by sestamibi imaging in patients with typical chest pain and normal coronary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Storto, Giovanni; Sorrentino, Anna R.; Pellegrino, Teresa; Liuzzi, Raffaele; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructures and Bioimages of the National Council of Research, Naples (Italy); Petretta, Mario [University Federico II, Department of Internal Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2007-08-15

    We assessed coronary flow reserve (CFR) by sestamibi imaging in patients with typical chest pain, positive exercise stress test and normal coronary vessels. Thirty-five patients with typical chest pain and normal angiogram and 12 control subjects with atypical chest pain underwent dipyridamole/rest {sup 99m}Tc-sestamibi imaging. Myocardial blood flow (MBF) was estimated by measuring first transit counts in the pulmonary artery and myocardial counts from SPECT images. Estimated CFR was expressed as the ratio of stress to rest MBF. Rest MBF and CFR were corrected for rate-pressure product (RPP) and expressed as normalised MBF (MBF{sub n}) and normalised CFR (CFR{sub n}). Coronary vascular resistances (CVR) were calculated as the ratio between mean arterial pressure and estimated MBF. At rest, estimated MBF and MBF{sub n} were lower in controls than in patients (0.98 {+-} 0.4 vs 1.30 {+-} 0.3 counts/pixel/s and 1.14 {+-} 0.5 vs 1.64 {+-} 0.6 counts/pixel/s, respectively, both p < 0.02). Stress MBF was not different between controls and patients (2.34 {+-} 0.8 vs 2.01 {+-} 0.7 counts/pixel/s, p=NS). Estimated CFR was 2.40 {+-} 0.3 in controls and 1.54 {+-} 0.3 in patients (p < 0.0001). After correction for the RPP, CFR{sub n} was still higher in controls than in patients (2.1 {+-} 0.5 vs 1.29 {+-} 0.5, p < 0.0001). At baseline, CVR values were lower (p < 0.01) in patients than in controls. Dipyridamole-induced changes in CVR were greater (p < 0.0001) in controls (-63%) than in patients (-35%). In the overall study population, a significant correlation between dipyridamole-induced changes in CVR and CFR was observed (r = -0.88, p < 0.0001). SPECT might represent a useful non-invasive method for assessing coronary vascular function in patients with angina and a normal coronary angiogram. (orig.)

  19. Noncontrast chest computed tomography immediately after transarterial chemoembolization in patients with hepatocellular carcinoma: Clinical benefits and effect of radiation reduction on image quality in low-dose scanning

    International Nuclear Information System (INIS)

    Choi, Joon-Il; Kim, Hyun Beom; Kim, Min Ju; Lee, Jong Seok; Koh, Young Whan; An, Sang Bu; Ko, Heung-kyu; Park, Joong-Won

    2011-01-01

    Purpose: To evaluate the clinical benefits of noncontrast chest computed tomography (CT) immediately after transarterial chemoembolization in patients with hepatocellular carcinoma and to assess the effect of radiation reduction on image quality in low-dose scanning. Materials and methods: From June to October 2010, we performed standard-dose, noncontrast chest CTs immediately after transarterial chemoembolization in 160 patients and low-dose CTs in 88 patients. We reviewed the entire noncontrast chest CTs and follow-up CTs to reveal the clinical benefits of CT evaluation immediately after transarterial chemoembolization. Using two independent readers, we also retrospectively evaluated the radiation dose and image quality in terms of the image noise, contrast between the liver parenchyma and iodized oil and diagnostic acceptability for the evaluation of treatment response after transarterial chemoembolization. Results: In 5.2% of the patients, additional treatment was performed immediately after the interpretation of the noncontrast chest CT, and additional pulmonary lesions were found in 8.5% of the patients. The measured mean dose-length product for the low-dose scanning was 18.4% of that of the standard-dose scanning. The image noise was significantly higher with the low-dose scanning (p < 0.001). However, all of the low-dose CT scans were diagnostically acceptable, and the mean scores for the subjective assessments of the contrast and diagnostic acceptability showed no significant differences for either reader. Conclusion: A noncontrast chest CT immediately after transarterial chemoembolization has some clinical benefits for immediate decision making and detecting pulmonary lesions. Low-dose, noncontrast chest CTs immediately after transarterial chemoembolization consistently provide diagnostically acceptable images and information on treatment response in patients who have undergone transarterial chemoembolization.

  20. High-resolution storage phosphor imaging of the chest: Comparison with conventional screen-film systems

    International Nuclear Information System (INIS)

    Fuhrman, C.R.; Good, B.; Feist, J.; Gur, D.; Darby, J.

    1987-01-01

    An experimental high-resolution storage phosphor imaging system (Eastman Kodak) has been used to evaluate the image quality and impact on diagnostic interpretation of storage phosphor images relative to conventional screen-film images of the same patients. The elements of the system include a high-resolution laser scanner (4K X 5K X 12 bit); an image processing system; and a high-resolution (4K X 5K X 12 bit) laser printer. Each case was digitally printed onto film in two different formats: a full-size (14 X 14-inch) and a half-size format of four processed, minified images (7 X 7-inches each). The multiformat image includes an original, an unsharp-masked, a reversed (black bone) unsharp-masked, and a high-contrast unsharp-masked image. The results of this preliminary study (11 cases, eight readers) clearly indicate that after minimal adjustment, radiologists do not object to making diagnoses from minified images. Unsharp masked images were considered preferable to unprocessed images, and processed storage phosphor images were rated significantly better than conventional film images

  1. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  2. Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT

    International Nuclear Information System (INIS)

    Barras, Heloise; Dunet, Vincent; Hachulla, Anne-Lise; Grimm, Jochen; Beigelman-Aubry, Catherine

    2016-01-01

    Model-based iterative reconstruction (MBIR) reduces image noise and improves image quality (IQ) but its influence on post-processing tools including maximal intensity projection (MIP) and minimal intensity projection (mIP) remains unknown. To evaluate the influence on IQ of MBIR on native, mIP, MIP axial and coronal reformats of reduced dose computed tomography (RD-CT) chest acquisition. Raw data of 50 patients, who underwent a standard dose CT (SD-CT) and a follow-up RD-CT with a CT dose index (CTDI) of 2–3 mGy, were reconstructed by MBIR and FBP. Native slices, 4-mm-thick MIP, and 3-mm-thick mIP axial and coronal reformats were generated. The relative IQ, subjective IQ, image noise, and number of artifacts were determined in order to compare different reconstructions of RD-CT with reference SD-CT. The lowest noise was observed with MBIR. RD-CT reconstructed by MBIR exhibited the best relative and subjective IQ on coronal view regardless of the post-processing tool. MBIR generated the lowest rate of artefacts on coronal mIP/MIP reformats and the highest one on axial reformats, mainly represented by distortions and stairsteps artifacts. The MBIR algorithm reduces image noise but generates more artifacts than FBP on axial mIP and MIP reformats of RD-CT. Conversely, it significantly improves IQ on coronal views, without increasing artifacts, regardless of the post-processing technique

  3. Properties of octagonal distance transformation (ODT) and its application to recognition of rib images of chest radiograms

    International Nuclear Information System (INIS)

    Ban, Tatsuya; Yokoi, Shigeki; Toriwaki, Jun-ichiro; Fukumura, Teruo.

    1980-01-01

    Digital image processing and image pattern recognition have lately become important, and are utilized in every field. The processing techniques common to these applications include smoothing, thinning, threshold processing, distance transformation, edge detection, etc. This paper describes the distance transformation, specifically the transformation based on octagonal distance (ODT). As the distance transformation, diamond distance or square distance has been employed so far, but these have the disadvantage of great deviation from the Euclid distance, and the octagonal distance transformation is considered to prevent such deviation. First, the basic concept and the definition of symbols are given, the octagonal distance skeleton (ODS) is defined, and the possibility of restoring original figure from the ODS is indicated. Next, the sequential algorithm is given, which executes the ODT and the inverse transformation to restore the original figure from the ODS by scanning on the figure 4 times. As an example of the application, the identification of rib images in chest radiograms is adopted, and the capability of reducing the effect of blood vessel images and noises by combining ODT with thinning or other processing, without quadratic function approximation, is described. (J.P.N.)

  4. Efficacy study of the digital image processing with varying pixel size at A/D conversion of the chest radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Inamoto, Kazuo; Tanaka, Shinichi; Miura, Takashi; Takahashi, Akira; Iwata, Tetsuya

    1984-12-01

    In the study for development of medical image archiving system, we made experiments in the field of conversion of a X-ray picture to a digital form. Three sets of chest radiograph were selected for the study of digitalization by reading different pixel size (150-300 m) in the method of A/D conversion using a drum scanner and again reconstructed to an analog form after D/A conversion. These copy films of different pixel size were shown and evaluated by 48 volunteer doctors to choose a favorite picture. It did not always follow that the most favorite picture was the finest one using the smallest pixel size. This discrepancy was further analyzed by measurement of a density histogram. By comparison studies of density curves in the same ROI of different pixel size pictures, it was concluded that their choices were dependent on not only fineness but also contrast of an output image after D/A conversion. Often better contrast picture was a key to the selection more than the pixel size. This indicates that digital storing radiographs will be possibly regenerated to the real image by the skillful operation of pixel size and contrast of a radiograph. The results will contribute to the process of recording analog X-ray picture by a digital form in the medical image archiving system.

  5. Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality

    International Nuclear Information System (INIS)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Kaup, Moritz; Beeres, Martin; Vogl, Thomas J.; Scholtz, Jan-Erik

    2017-01-01

    Most of the applied radiation dose at CT is in the lower photon energy range, which is of limited diagnostic importance. To investigate image quality and effects on radiation parameters of 100-kVp spectral filtration single-energy chest CT using a tin-filter at third-generation dual-source CT in comparison to standard 100-kVp chest CT. Thirty-three children referred for a non-contrast chest CT performed on a third-generation dual-source CT scanner were examined at 100 kVp with a dedicated tin filter with a tube current-time product resulting in standard protocol dose. We compared resulting images with images from children examined using standard single-source chest CT at 100 kVp. We assessed objective and subjective image quality and compared radiation dose parameters. Radiation dose was comparable for children 5 years old and younger, and it was moderately decreased for older children when using spectral filtration (P=0.006). Effective tube current increased significantly (P=0.0001) with spectral filtration, up to a factor of 10. Signal-to-noise ratio and image noise were similar for both examination techniques (P≥0.06). Subjective image quality showed no significant differences (P≥0.2). Using 100-kVp spectral filtration chest CT in children by means of a tube-based tin-filter on a third-generation dual-source CT scanner increases effective tube current up to a factor of 10 to provide similar image quality at equivalent dose compared to standard single-source CT without spectral filtration. (orig.)

  6. Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Kaup, Moritz; Beeres, Martin; Vogl, Thomas J.; Scholtz, Jan-Erik [Goethe University of Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-06-15

    Most of the applied radiation dose at CT is in the lower photon energy range, which is of limited diagnostic importance. To investigate image quality and effects on radiation parameters of 100-kVp spectral filtration single-energy chest CT using a tin-filter at third-generation dual-source CT in comparison to standard 100-kVp chest CT. Thirty-three children referred for a non-contrast chest CT performed on a third-generation dual-source CT scanner were examined at 100 kVp with a dedicated tin filter with a tube current-time product resulting in standard protocol dose. We compared resulting images with images from children examined using standard single-source chest CT at 100 kVp. We assessed objective and subjective image quality and compared radiation dose parameters. Radiation dose was comparable for children 5 years old and younger, and it was moderately decreased for older children when using spectral filtration (P=0.006). Effective tube current increased significantly (P=0.0001) with spectral filtration, up to a factor of 10. Signal-to-noise ratio and image noise were similar for both examination techniques (P≥0.06). Subjective image quality showed no significant differences (P≥0.2). Using 100-kVp spectral filtration chest CT in children by means of a tube-based tin-filter on a third-generation dual-source CT scanner increases effective tube current up to a factor of 10 to provide similar image quality at equivalent dose compared to standard single-source CT without spectral filtration. (orig.)

  7. Testing the radiochemical purity of a radiopharmaceutical: study of 99mTc-Tetrofosmin (Myoview)

    International Nuclear Information System (INIS)

    Moati, F.; Quartarone, C.; Jourdain, J.R.; Rizzo, N.; Dumont, A.; De Beco, V.; Ait Ben Ali, S.; Lours, S.; Piketty, M.L.; Izembart, M.; Goudou, C.; Lemercier, V.; Schlageter, M.H.; Moretti, J.L.; Progent, A.

    1997-01-01

    The goal of this study is to optimize the testing method of radiochemical purity (RCP) of 99m Tc-Tetrofosmin proposed by the Amersham Company: thin-layer chromatography (TLC); ITLC-SG support, migration on 15 Cm; acetone-dichloromethane mobile phase, (35/65, v/v), This technique allows separating the reduced-Tc (Rf = 0), the TcO 4 - (Rf = 1), and in intermediary position (0.2 99m Tc-Tetrofosmin. The results of RCP depend on working conditions, particularly, on the volume of deposit (10 to 20 μl, expected). If the deposited is too small, the 99m Tc-Tetrofosmin does not migrate. With a volume of 20 μl, the separation is weak and the peak width is un-resolvable. The results obtained correspond to the following operational conditions: migration on 8 cm; deposit of 8 to 10 μl; no drying. In these conditions the peak of 99m Tc-Tetrofosmin is well singled out: migration Rf of 0.375 to 0.625. These results have been obtained by the analysis of radio-chromatographic peak. Every strip has been cut cm by cm and the activity was measured by a gamma counter. Repeatability of the method on a series of 8 tests is good: average RCP 93.22%, mean value = 93.24%. The reproducibility was realized by measuring directly by the activity-meter the activity corresponding to 3 identifiable peaks: Reduced Tc (Rf 4 - (Rf 99m Tc-Tetrofosmin (0.25 < Rf < 0.75). On the 21 effectuated tests the inter-test RCP reproducibility was good: average value = 95.24%, CV = 2.07%, mean value 95.3%). In conclusion, the miniaturization improves the separation by Myoview (0.25 < Rf < 0.75), diminishes the migration time by a factor 4 and lowers the reactive cost of testing by 50%

  8. Assessment of noise reduction potential and image quality improvement of a new generation adaptive statistical iterative reconstruction (ASIR-V) in chest CT.

    Science.gov (United States)

    Tang, Hui; Yu, Nan; Jia, Yongjun; Yu, Yong; Duan, Haifeng; Han, Dong; Ma, Guangming; Ren, Chenglong; He, Taiping

    2018-01-01

    To evaluate the image quality improvement and noise reduction in routine dose, non-enhanced chest CT imaging by using a new generation adaptive statistical iterative reconstruction (ASIR-V) in comparison with ASIR algorithm. 30 patients who underwent routine dose, non-enhanced chest CT using GE Discovery CT750HU (GE Healthcare, Waukesha, WI) were included. The scan parameters included tube voltage of 120 kVp, automatic tube current modulation to obtain a noise index of 14HU, rotation speed of 0.6 s, pitch of 1.375:1 and slice thickness of 5 mm. After scanning, all scans were reconstructed with the recommended level of 40%ASIR for comparison purpose and different percentages of ASIR-V from 10% to 100% in a 10% increment. The CT attenuation values and SD of the subcutaneous fat, back muscle and descending aorta were measured at the level of tracheal carina of all reconstructed images. The signal-to-noise ratio (SNR) was calculated with SD representing image noise. The subjective image quality was independently evaluated by two experienced radiologists. For all ASIR-V images, the objective image noise (SD) of fat, muscle and aorta decreased and SNR increased along with increasing ASIR-V percentage. The SD of 30% ASIR-V to 100% ASIR-V was significantly lower than that of 40% ASIR (p ASIR-V reconstructions had good diagnostic acceptability. However, the 50% ASIR-V to 70% ASIR-V series showed significantly superior visibility of small structures when compared with the 40% ASIR and ASIR-V of other percentages (p ASIR-V was the best series of all ASIR-V images, with a highest subjective image quality. The image sharpness was significantly decreased in images reconstructed by 80% ASIR-V and higher. In routine dose, non-enhanced chest CT, ASIR-V shows greater potential in reducing image noise and artefacts and maintaining image sharpness when compared to the recommended level of 40%ASIR algorithm. Combining both the objective and subjective evaluation of images, non

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... transplant, it will be necessary to perform a blood test to determine whether the kidneys are functioning adequately. ... abnormalities where Chest CT is a preferred imaging test. MR imaging can assess blood flow without risking the side effects of conventional ( ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to evaluate various ... seen by other imaging modalities, such as chest x-ray or CT. A special form of MRI called ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to evaluate various ... seen by other imaging modalities, such as chest x-ray or CT. A special form of MRI called ...

  12. FLAIL CHEST

    Directory of Open Access Journals (Sweden)

    Anton Crnjac

    2003-12-01

    Full Text Available Background. Major thoracic trauma is consistent with high mortality rate because of associated injuries of vital thoracic organs and dangerous complications. The flail chest occurs after disruption of the skeletal continuity of chest wall and demands because of its pathophysiological complexity rapid and accurate diagnosis and treatment.Conclusions. Basic pathophysiological mechanism of the flail chest is respiratory distress, which is provoked by pulmonary contusions and paradoxical chest wall motion. The treatment should be pointed to improvement and support of respiratory functions and include aggressive pain control, pulmonary physiotherapy and selective mechanical ventilation. Views about operative fixation of the flail chest are still controversial. Neither mortality rate neither long-term disability are improved after operative fixation.

  13. Detection of tuberculosis patterns in digital photographs of chest X-ray images using Deep Learning: feasibility study.

    Science.gov (United States)

    Becker, A S; Blüthgen, C; Phi van, V D; Sekaggya-Wiltshire, C; Castelnuovo, B; Kambugu, A; Fehr, J; Frauenfelder, T

    2018-03-01

    To evaluate the feasibility of Deep Learning-based detection and classification of pathological patterns in a set of digital photographs of chest X-ray (CXR) images of tuberculosis (TB) patients. In this prospective, observational study, patients with previously diagnosed TB were enrolled. Photographs of their CXRs were taken using a consumer-grade digital still camera. The images were stratified by pathological patterns into classes: cavity, consolidation, effusion, interstitial changes, miliary pattern or normal examination. Image analysis was performed with commercially available Deep Learning software in two steps. Pathological areas were first localised; detected areas were then classified. Detection was assessed using receiver operating characteristics (ROC) analysis, and classification using a confusion matrix. The study cohort was 138 patients with human immunodeficiency virus (HIV) and TB co-infection (median age 34 years, IQR 28-40); 54 patients were female. Localisation of pathological areas was excellent (area under the ROC curve 0.82). The software could perfectly distinguish pleural effusions from intraparenchymal changes. The most frequent misclassifications were consolidations as cavitations, and miliary patterns as interstitial patterns (and vice versa). Deep Learning analysis of CXR photographs is a promising tool. Further efforts are needed to build larger, high-quality data sets to achieve better diagnostic performance.

  14. Cardiac magnetic resonance imaging in patients with chest pain, high troponin levels and absence of coronary artery obstruction

    International Nuclear Information System (INIS)

    Avegliano, G.P.; Costabel, J.P.; Kuschnir, P.; Thierer, J.; Alves de Lima, A.; Sanchez, G.; Ronderos, J.; Huguet, M.; Petit, M.; Frangi, A.A.

    2011-01-01

    The prevalence of myocardial infarction with angiographically normal coronary arteries is approximately 7-10%. The etiological diagnosis is sometimes difficult and is important in terms of clinical practice and prognosis. The goal of our study was to show a series of consecutive patients with an initial diagnosis of acute coronary syndrome with high troponin levels and absence of coronary artery obstruction in which cardiac magnetic resonance imaging (CMRI) gave a description of the myocardial lesion, orientating towards the etiological diagnosis. From January 2005 to December 2009, 720 consecutive patients with an initial diagnosis of acute coronary syndrome and elevated troponins were included; 64 of these patients did not present angiographically significant coronary artery stenosis. Within 72 ± 24 h after coronary angiography, these patients underwent CMRI using b-SSFP sequences for cine imaging in short-axis, 2-, 3- and 4- chamber views for the evaluation of segmental wall motion, with T2-weighted and delayed enhancement (DE) images of the myocardium with an 'inversion-recovery' sequence. The following diagnoses were made: myocarditis (39 patients); myocardial infarction (12 patients); Tako-Tsubo syndrome (8 patients); apical hypertrophic cardiomyopathy (2 patients); 3 patients remained without diagnosis. These findings demonstrate the usefulness of CMRI in the clinical scenario of patients with chest pain, inconclusive ECG findings and high troponin levels with angiographically normal coronary arteries. The presence and distribution pattern of DE make it possible to define the etiological diagnosis and interpret the physiopathological process. (authors) [es

  15. Digital chest radiography with an amorphous silicon flat-panel-detector versus a storage-phosphor system: comparison of soft-copy images

    International Nuclear Information System (INIS)

    Lee, Hyun Ju; Im, Jung Gi; Goo, Jin Mo; Lee, Chang Hyun

    2006-01-01

    We compared the soft-copy images produced by an amorphous silicon flat-panel-detector system with the images produced by a storage-phosphor radiography system for their ability to visualize anatomic regions of the chest. Two chest radiologists independently analyzed 234 posteroanterior chest radiographs obtained from 78 patients on high-resolution liquid crystal display monitors (2560 x 2048 x 8 bits). In each patient, one radiograph was obtained with a storage-phosphor system, and two radiographs were obtained via amorphous silicon flat-panel-detector radiography with and without spatial frequency filtering. After randomizing the 234 images, the interpreters rated the visibility and radiographic quality of 11 different anatomic regions. Each image was ranked on a five-point scale (1 = not visualized, 2 = poor visualization, 3 = fair visualization, 4 = good visualization, and 5 = excellent visualization). The statistical difference between each system was determined using the Wilcoxon's signed rank test. The visibility of three anatomic regions (hilum, heart border and ribs), as determined by the chest radiologist with 14 years experience (ρ < 0.05) and the visibility of the thoracic spine, as determined by the chest radiologist with 8 years experience (ρ = 0.036), on the amorphous silicon flat-panel-detector radiography prior to spatial frequency filtering were significantly superior to that on the storage-phosphor radiography. The visibility of 11 anatomic regions, as determined by the chest radiologist with 14 years experience (ρ < 0.0001) and the visibility of five anatomic regions (unobscured lung, rib, proximal airway, thoracic spine and overall appearance), as determined by the chest radiologist with 8 years experience (ρ < 0.05), on the amorphous silicon flat-panel-detector radiography after spatial frequency filtering were significantly superior to that on the storage-phosphor radiography. The amorphous silicon flat-panel-detector system depicted the

  16. Objective quantification of pulmonary effects in X-ray chest images; Quantificacao objetiva das sequelas pulmonares em imagens de raios-X de torax

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Marcela de; Giacomini, Guilherme; Alvarez, Matheus; Pereira, Paulo M.C.; Ribeiro, Sergio M.; Pina, Diana R. de [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2016-07-01

    Tuberculosis (TB) is an infectious lung disease of great concern worldwide. Even after treatment, TB leaves pulmonary sequelae that compromise the quality of life of patients. The exam of diagnostic imaging done more frequently is the X-ray chest. The evaluation of pulmonary involvement of these patients is performed visually by the radiologist. The detection and quantification aided by computer systems are of great importance for the more accurate assessment of pulmonary involvement. The objective of this study was to evaluate computationally the reduction of lung damage in X-ray of chest in patients treated with two different medication regimens. (author)

  17. Radiation doses and image quality in pediatric chest X-ray for the diagnosis of pneumonia in selected Latin American countries

    International Nuclear Information System (INIS)

    Jimenez, P.; Fleitas, I.; Cotelo, E.; Estevan, M.

    2008-01-01

    Full text: Pneumonia and acute lower respiratory infections in general, is the leading cause of child death in developing countries. According to the World Health Organization (WHO), 4 millions of children die annually due to this disease. Despite the growing use of vaccination as an alternate approach to reduce mortality, the increasing antimicrobial resistance and the high costs of vaccines remain important obstacles in the global struggle against the disease. The usual treatment strategy begins with a clinical examination of the patient followed by the prescription of a chest X-ray. Radiography would appear as the best available method for diagnosing pneumonia only if radiologists (and other health professionals such as pediatricians) knew how to interpret the images showed in the radiographs, and these meeting the standards of quality (anatomic structures, image contrast and optical density, and patient dose among other factors). On the other hand, special attention should be paid on patient doses due to children's specific radiosensitivity, repeated and extended use of chest x-ray in all Radiology Departments, and high rejection rate due to both equipment malfunction and to human skills shortcomings. Patient doses of chest X-ray performed to children less than 5 years old in PAHO Sentinel Hospitals for surveillance of bacterial pneumonias in various Latin American countries were estimated using technical parameters and equipment specifications. Image quality was compared to WHO criteria for chest X-rays quality. Results showing differences in patient doses translates on one hand the impact of specific characteristics of the radiological equipment, including equipment limitations and performance of the radiographs and on the other various and divers levels of health professionals skills and training on image quality interpretation and dose optimization. The study concludes that professionals' training and education on chest radiographs image quality constitutes

  18. Radiologic images of an aggressive implant-associated fibromatosis of the breast and chest wall: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Lourdes Alanis, MD, MPH

    2017-09-01

    Full Text Available Fibromatosis of the breast is a rare benign disease compromising <0.2% of all primary breast tumors. Although the chest wall is a common location, occurrences of implant-associated fibromatosis of the breast are extremely rare; only 33 cases have been reported. We present a case of a 42-year-old female who underwent breast augmentation with silicone breast implants, and 2 years later developed an aggressive implant-associated fibromatosis of the breast and chest wall. On imaging studies, the tumor mimicked breast carcinoma, and despite chemotherapy, the fibromatosis rapidly enlarged and was locally invasive requiring wide surgical excision. Unlike previously reported imaging findings, magnetic resonance imaging revealed an oval circumscribed mass with fringe-like internal architecture. We provide a review of the literature and discuss the imaging features of implant-associated fibromatosis of the breast.

  19. Performance evaluation of 3-D enhancement filters for detection of lung cancer from 3-D chest X-ray CT images

    International Nuclear Information System (INIS)

    Shimizu, Akinobu; Hagai, Makoto; Toriwaki, Jun-ichiro; Hasegawa, Jun-ichi.

    1995-01-01

    This paper evaluates the performance of several three dimensional enhancement filters used in procedures for detecting lung cancer shadows from three dimensional (3D) chest X-ray CT images. Two dimensional enhancement filters such as Min-DD filter, Contrast filter and N-Quoit filter have been proposed for enhancing cancer shadows in conventional 2D X-ray images. In this paper, we extend each of these 2D filters to a 3D filter and evaluate its performance experimentally by using CT images with artificial and true lung cancer shadows. As a result, we find that these 3D filters are effective for determining the position of a lung cancer shadow in a 3D chest CT image, as compared with the simple procedure such as smoothing filter, and that the performance of these filters become lower in the hilar area due to the influence of the vessel shadows. (author)

  20. Troponin-positive chest pain with unobstructed coronary arteries: incremental diagnostic value of cardiovascular magnetic resonance imaging.

    Science.gov (United States)

    Pathik, Bhupesh; Raman, Betty; Mohd Amin, Nor Hanim; Mahadavan, Devan; Rajendran, Sharmalar; McGavigan, Andrew D; Grover, Suchi; Smith, Emma; Mazhar, Jawad; Bridgman, Cameron; Ganesan, Anand N; Selvanayagam, Joseph B

    2016-10-01

    Troponin-positive chest pain patients with unobstructed coronaries represent a clinical dilemma. Cardiovascular magnetic resonance (CMR) imaging has an increasingly prominent role in the assessment of these patients; however, its utility in addition to expert clinical judgement is unclear. We sought to determine the incremental diagnostic value of CMR and the heterogeneity in diagnoses by experienced cardiologists when presented with blinded clinical and investigative data in this population. A total of 125 consecutive patients presenting to a tertiary centre between 2010 and 2014 with cardiac chest pain, elevated troponin (>29 ng/L), and unobstructed coronaries were enrolled and underwent CMR. A panel of three experienced cardiologists unaware of the CMR diagnosis and blinded to each other's assessment provided a diagnosis based on clinical and investigative findings. A consensus panel diagnosis was defined as two or more cardiologists sharing the same clinical diagnosis. Findings were classified into acute myocarditis, Takotsubo cardiomyopathy, acute myocardial infarction (AMI), or indeterminate. CMR provided a diagnosis in 87% of patients. Consensus panel diagnosis and CMR were concordant in 65/125 (52%) patients. There was an only moderate level of agreement between the three cardiologists (k = 0.47, P < 0.05) and a poor level of agreement between the consensus panel and CMR (k = 0.38, P < 0.05) with the most disagreement seen in patients with AMI diagnosed on CMR. The clinical diagnosis of patients with non-obstructive coronaries and positive troponin remains a challenge. The concordance between CMR and clinical diagnosis is poor. CMR provides a diagnosis in majority of these patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  1. Chest sonography. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Mathis, Gebhard (ed.)

    2008-07-01

    Chest sonography is an established procedure in the stepwise imaging diagnosis of pulmonary and pleural disease. It is the method of choice to distinguish between solid and liquid lesions and allows the investigator to make an unequivocal diagnosis without exposing the patient to costly and stressful procedures. This book presents the state of the art in chest investigation by means of ultrasonography. A number of excellent illustrations and the compact text provide concise and easy-to-assimilate information about the diagnostic procedure. Basic elements such as indications, investigation techniques and image artifacts are detailed in separate chapters. (orig.)

  2. Chest sonography. 2. ed.

    International Nuclear Information System (INIS)

    Mathis, Gebhard

    2008-01-01

    Chest sonography is an established procedure in the stepwise imaging diagnosis of pulmonary and pleural disease. It is the method of choice to distinguish between solid and liquid lesions and allows the investigator to make an unequivocal diagnosis without exposing the patient to costly and stressful procedures. This book presents the state of the art in chest investigation by means of ultrasonography. A number of excellent illustrations and the compact text provide concise and easy-to-assimilate information about the diagnostic procedure. Basic elements such as indications, investigation techniques and image artifacts are detailed in separate chapters. (orig.)

  3. Effects of tube potential and scatter rejection on image quality and effective dose in digital chest X-ray examination: An anthropomorphic phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, D.J., E-mail: daniel.shaw@christie.nhs.uk [Diagnostic Radiology, Department of Medical Physics and Engineering, Leeds Teaching Hospitals, Leeds General Infirmary, Great George Street, Leeds LS1 3EX (United Kingdom); Crawshaw, I. [Diagnostic X-ray Department, York Teaching Hospital NHS Foundation Trust, The York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Rimmer, S. D. [Diagnostic Radiology, Department of Medical Physics and Engineering, Leeds Teaching Hospitals, Leeds General Infirmary, Great George Street, Leeds LS1 3EX (United Kingdom)

    2013-11-15

    Objectives: The purpose of this study was to investigate the effects of tube potential and scatter rejection techniques on image quality of digital posteroanterior (PA) chest radiographs. Methods: An anthropomorphic phantom was imaged using a range of tube potentials (81–125 kV{sub p}) without scatter rejection, with an anti-scatter grid, and using a 10 cm air gap. Images were anonymised and randomised before being evaluated using a visual graded analysis (VGA) method. Results: The effects of tube potential on image quality were found to be negligible (p > 0.63) for the flat panel detector (FPD). Decreased image quality (p = 0.031) was noted for 125 kV{sub p} relative to 109 kV{sub p}, though no difference was noted for any of the other potentials (p > 0.398) for computed radiography (CR). Both scatter rejection techniques improved image quality (p < 0.01). For FPD imaging the anti-scatter grid offered slightly improved image quality relative to the air gap (p = 0.038) but this was not seen for CR (p = 0.404). Conclusions: For FPD chest imaging of the anthropomorphic phantom there was no dependence of image quality on tube potential. Scatter rejection improved image quality, with the anti-scatter grid giving greater improvements than an air-gap, but at the expense of increased effective dose. CR imaging of the chest phantom demonstrated negligible dependence on tube potential except at 125 kV{sub p}. Scatter rejection improved image quality, but with no difference found between techniques. The air-gap resulted in a smaller increase in effective dose than the anti-scatter grid and would be the preferred scatter rejection technique.

  4. Eigenimage filtering in MR imaging: Application in the abnormal chest wall

    International Nuclear Information System (INIS)

    Compton, R.A.; Kormos, D.W.; Kritzer, M.R.; Lent, A.H.; Murdoch, J.B.; Yeung, H.N.

    1986-01-01

    Three-dimensional multislab acquisition permits the simultaneous imaging of many thin sections in selected ''slabs.'' The technique was proposed in 1985, clinically validated in 1986, and has now been further improved by recent work. The authors have applied the methodology of 1985 to design new ''slabcutter'' 90 0 and 180 0 radio frequency pulses that excite slabs which are ''squarer'' than any previously known. These new pulses increase the number of usable sections per slab by 40% and also improve image quality. They demonstrate the enhancement by imaging two separate slabs of the temporomandibular joint simultaneously

  5. Regionally adaptive histogram equalization of the chest

    International Nuclear Information System (INIS)

    Sherrier, R.H.; Johnson, G.A.

    1986-01-01

    Advances in digital chest radiography have resulted in the acquisition of high-quality digital images of the human chest. With these advances, there arises a genuine need for image processing algorithms, specific to chest images. The author has implemented the technique of histogram equalization, noting the problems encountered when it is adapted to chest images. These problems have been successfully solved with a regionally adaptive histogram equalization method. Histograms are calculated locally and then modified according to both the mean pixel value of a given region and certain characteristics of the cumulative distribution function. The method allows certain regions of the chest radiograph to be enhanced differentially

  6. Radiation levels and image quality in patients undergoing chest X-ray examinations

    International Nuclear Information System (INIS)

    Campos de Oliveira, Paulo Márcio; Carmo Santana, Priscila do; Sousa Lacerda, Marco Aurélio de; Silva, Teógenes Augusto da

    2017-01-01

    Patient dose monitoring for different radiographic procedures has been used as a parameter to evaluate the performance of radiology services; skin entrance absorbed dose values for each type of examination were internationally established and recommended aiming patient protection. In this work, a methodology for dose evaluation was applied to three diagnostic services: one with a conventional film and two with digital computerized radiography processing techniques. The x-ray beam parameters were selected and “doses” (specifically the entrance surface and incident air kerma) were evaluated based on images approved in European criteria during postero-anterior (PA) and lateral (LAT) incidences. Data were collected from 200 patients related to 200 PA and 100 LAT incidences. Results showed that doses distributions in the three diagnostic services were very different; the best relation between dose and image quality was found in the institution with the chemical film processing. This work contributed for disseminating the radiation protection culture by emphasizing the need of a continuous dose reduction without losing the quality of the diagnostic image. - Highlights: • A methodology for dose evaluation was applied to three diagnostic services. • The doses in patients were evaluated when the images were adequate. • Data were collected from 200 patients. • Is possible doses optimization with digital system without an image quality reduction. • The best dose and image quality was found in chemical film processing.

  7. Chest radiology

    International Nuclear Information System (INIS)

    Reed, J.C.

    1990-01-01

    This book is a reference in plain chest film diagnosis provides a thorough background in the differential diagnosis of 22 of the most common radiologic patterns of chest disease. Each chapter is introduced with problem cases and a set of questions, followed by a tabular listing of the appropriate differential considerations. The book emphasizes plain films, CT and some MR scans are integrated to demonstrate how these modalities enhance the work of a case

  8. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  9. Scintigraphic study of palpable breast nodes with {sup 99m} Tc-tetrofosmin; Estudo cintilografico de nodulos palpaveis da mama com {sup 99m} Tc - tetrofosmin

    Energy Technology Data Exchange (ETDEWEB)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Amarante Junior, Jose Luiz de Medeiros [Hospital Naval Marcilio Dias, Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear; Fabricio, Maria Ines Menescal [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Ginecologia

    1998-12-01

    In Brazil, breast carcinoma has the greater incidence among women. In 1996, about 31,210 new cases were diagnosed. The purpose of this study is to determine if {sup 99m} technetium-tetrofosmin preferentially concentrates within malignant palpable breast nodes, distinguishing them from the benign lumps. Fifth-four consecutive and unsolicited women, mean age 47.5 +- 10.7 years, with palpable nodes in breast, underwent breast scintigraphy with {sup 99m} technetium-tetrofosmin and excisional biopsy or fine needle puncture within interval eight weeks. Histopathologic studies demonstrated 13 cysts, 1 cyst with local inflammation, 11 fibroadenoma, 2 fibrodysplasias, 3 fibroadenomas with high cellularity, 1 fibrocystic change with local inflammation, 23 invasive intraductal carcinomas and 1 invasive lobular carcinoma. The nodes ranged from 10 to 100 mm in greater diameter. The scintigraphic study yielded 30 true-negative cases, 24 true-positives, no false-negative and 1 false-positive. This case was a fibrocystic lump with local inflammation. Two patients had metastases in axillary lymph nodes, well detected in scintigraphy. The statistic analysis showed: sensitivity, 100%; specificity, 96.8%; accuracy, 98.2%; negative predictive value, 100%; positive predictive value, 96.0%. Nonparametric tests of Fisher and Chi-square rejected the antithesis at a confidence interval of 99.9% (p < 0.001). We concluded that {sup 99m} technetium-tetrofosmin preferentially concentrates in malignant palpable breast nodes and can help to distinguish them from the benign tumors with with very high accuracy. (author)

  10. A computer-aided diagnosis system to detect pathologies in temporal subtraction images of chest radiographs

    Science.gov (United States)

    Looper, Jared; Harrison, Melanie; Armato, Samuel G.

    2016-03-01

    Radiologists often compare sequential radiographs to identify areas of pathologic change; however, this process is prone to error, as human anatomy can obscure the regions of change, causing the radiologists to overlook pathology. Temporal subtraction (TS) images can provide enhanced visualization of regions of change in sequential radiographs and allow radiologists to better detect areas of change in radiographs. Not all areas of change shown in TS images, however, are actual pathology. The purpose of this study was to create a computer-aided diagnostic (CAD) system that identifies which regions of change are caused by pathology and which are caused by misregistration of the radiographs used to create the TS image. The dataset used in this study contained 120 images with 74 pathologic regions on 54 images outlined by an experienced radiologist. High and low ("light" and "dark") gray-level candidate regions were extracted from the images using gray-level thresholding. Then, sampling techniques were used to address the class imbalance problem between "true" and "false" candidate regions. Next, the datasets of light candidate regions, dark candidate regions, and the combined set of light and dark candidate regions were used as training and testing data for classifiers by using five-fold cross validation. Of the classifiers tested (support vector machines, discriminant analyses, logistic regression, and k-nearest neighbors), the support vector machine on the combined candidates using synthetic minority oversampling technique (SMOTE) performed best with an area under the receiver operating characteristic curve value of 0.85, a sensitivity of 85%, and a specificity of 84%.

  11. TU-FG-209-11: Validation of a Channelized Hotelling Observer to Optimize Chest Radiography Image Processing for Nodule Detection: A Human Observer Study

    International Nuclear Information System (INIS)

    Sanchez, A; Little, K; Chung, J; Lu, ZF; MacMahon, H; Reiser, I

    2016-01-01

    Purpose: To validate the use of a Channelized Hotelling Observer (CHO) model for guiding image processing parameter selection and enable improved nodule detection in digital chest radiography. Methods: In a previous study, an anthropomorphic chest phantom was imaged with and without PMMA simulated nodules using a GE Discovery XR656 digital radiography system. The impact of image processing parameters was then explored using a CHO with 10 Laguerre-Gauss channels. In this work, we validate the CHO’s trend in nodule detectability as a function of two processing parameters by conducting a signal-known-exactly, multi-reader-multi-case (MRMC) ROC observer study. Five naive readers scored confidence of nodule visualization in 384 images with 50% nodule prevalence. The image backgrounds were regions-of-interest extracted from 6 normal patient scans, and the digitally inserted simulated nodules were obtained from phantom data in previous work. Each patient image was processed with both a near-optimal and a worst-case parameter combination, as determined by the CHO for nodule detection. The same 192 ROIs were used for each image processing method, with 32 randomly selected lung ROIs per patient image. Finally, the MRMC data was analyzed using the freely available iMRMC software of Gallas et al. Results: The image processing parameters which were optimized for the CHO led to a statistically significant improvement (p=0.049) in human observer AUC from 0.78 to 0.86, relative to the image processing implementation which produced the lowest CHO performance. Conclusion: Differences in user-selectable image processing methods on a commercially available digital radiography system were shown to have a marked impact on performance of human observers in the task of lung nodule detection. Further, the effect of processing on humans was similar to the effect on CHO performance. Future work will expand this study to include a wider range of detection/classification tasks and more

  12. Advanced-stage Hodgkin lymphoma: US/chest radiography for detection of relapse in patients in first complete remission--a randomized trial of routine surveillance imaging procedures.

    Science.gov (United States)

    Picardi, Marco; Pugliese, Novella; Cirillo, Michele; Zeppa, Pio; Cozzolino, Imma; Ciancia, Giuseppe; Pettinato, Guido; Salvatore, Claudia; Quintarelli, Concetta; Pane, Fabrizio

    2014-07-01

    To compare the use of fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) with the use of a combination of ultrasonography (US) and chest radiography for systematic follow-up of patients with high-risk Hodgkin lymphoma. Institutional review board approval and informed consent were obtained. In a single center between January 2001 and December 2009, patients with advanced-stage Hodgkin lymphoma who had responded completely to first-line treatment were randomly assigned (1:1) to follow-up with either PET/CT or US/chest radiography. Follow-up included clinical and imaging procedures at 4, 8, 12, 16, 20, 24, 30, 36, 48, 60, 84, and 108 months after treatment discontinuation. When clinical and/or imaging results were positive, recurrence was confirmed histologically. The primary endpoint was to compare the sensitivity of the two follow-up imaging approaches. Secondary endpoints were their specificity, positive and negative predictive values, time to recurrence detection, radiation risks, and costs. A total of 300 patients were randomized into the two arms. The study was closed after a median follow-up time of 60 months, with a relapse rate of 27%. Sensitivity for detection of Hodgkin lymphoma was similar for the two follow-up approaches. All of the relapses (40 of 40) were identified with FDG PET/CT (100%) and 39 of 40 relapses were identified with US/chest radiography (97.5%; P = .0001 for the equivalence test). US/chest radiography showed significantly higher specificity and positive predictive value than did PET/CT (96% [106 of 110] vs 86% [95 of 110], respectively; P = .02; and 91% [39 of 43] vs 73% [40 of 55], respectively; P = .01). Exposure to ionizing radiation was estimated to be 14.5 mSv for one PET/CT examination versus 0.1 mSv for one chest radiographic examination. Estimated cost per relapse diagnosed with routine PET/CT was 10-fold higher compared with that diagnosed with routine US/chest radiography. US and

  13. Digital chest radiography: an update on modern technology, dose containment and control of image quality

    NARCIS (Netherlands)

    Schaefer-Prokop, Cornelia; Neitzel, Ulrich; Venema, Henk W.; Uffmann, Martin; Prokop, Mathias

    2008-01-01

    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose

  14. Digital chest radiography: an update on modern technology, dose containment and control of image quality

    International Nuclear Information System (INIS)

    Schaefer-Prokop, Cornelia; Venema, Henk W.; Neitzel, Ulrich; Uffmann, Martin; Prokop, Mathias

    2008-01-01

    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems. (orig.)

  15. Entrance surface dose and image quality: Comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia

    International Nuclear Information System (INIS)

    Hambali, A. S.; Ng, K. H.; Abdullah, B. J. J.; Wang, H. B.; Jamal, N.; Spelic, D. C.; Suleiman, O. H.

    2009-01-01

    This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia. (authors)

  16. Image quality in children with low-radiation chest CT using adaptive statistical iterative reconstruction and model-based iterative reconstruction.

    Directory of Open Access Journals (Sweden)

    Jihang Sun

    Full Text Available OBJECTIVE: To evaluate noise reduction and image quality improvement in low-radiation dose chest CT images in children using adaptive statistical iterative reconstruction (ASIR and a full model-based iterative reconstruction (MBIR algorithm. METHODS: Forty-five children (age ranging from 28 days to 6 years, median of 1.8 years who received low-dose chest CT scans were included. Age-dependent noise index (NI was used for acquisition. Images were retrospectively reconstructed using three methods: MBIR, 60% of ASIR and 40% of conventional filtered back-projection (FBP, and FBP. The subjective quality of the images was independently evaluated by two radiologists. Objective noises in the left ventricle (LV, muscle, fat, descending aorta and lung field at the layer with the largest cross-section area of LV were measured, with the region of interest about one fourth to half of the area of descending aorta. Optimized signal-to-noise ratio (SNR was calculated. RESULT: In terms of subjective quality, MBIR images were significantly better than ASIR and FBP in image noise and visibility of tiny structures, but blurred edges were observed. In terms of objective noise, MBIR and ASIR reconstruction decreased the image noise by 55.2% and 31.8%, respectively, for LV compared with FBP. Similarly, MBIR and ASIR reconstruction increased the SNR by 124.0% and 46.2%, respectively, compared with FBP. CONCLUSION: Compared with FBP and ASIR, overall image quality and noise reduction were significantly improved by MBIR. MBIR image could reconstruct eligible chest CT images in children with lower radiation dose.

  17. High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography.

    Science.gov (United States)

    Lell, Michael M; May, Matthias; Deak, Paul; Alibek, Sedat; Kuefner, Michael; Kuettner, Axel; Köhler, Henrik; Achenbach, Stephan; Uder, Michael; Radkow, Tanja

    2011-02-01

    computed tomography (CT) is considered the method of choice in thoracic imaging for a variety of indications. Sedation is usually necessary to enable CT and to avoid deterioration of image quality because of patient movement in small children. We evaluated a new, subsecond high-pitch scan mode (HPM), which obviates the need of sedation and to hold the breath. a total of 60 patients were included in this study. 30 patients (mean age, 14 ± 17 month; range, 0-55 month) were examined with a dual source CT system in an HPM. Scan parameters were as follows: pitch = 3.0, 128 × 0.6 mm slice acquisition, 0.28 seconds gantry rotation time, ref. mAs adapted to the body weight (50-100 mAs) at 80 kV. Images were reconstructed with a slice thickness of 0.75 mm. None of the children was sedated for the CT examination and no breathing instructions were given. Image quality was assessed focusing on motion artifacts and delineation of the vascular structures and lung parenchyma. Thirty patients (mean age, 15 ± 17 month; range, 0-55 month) were examined under sedation on 2 different CT systems (10-slice CT, n = 18; 64-slice CT, n = 13 patients) in conventional pitch mode (CPM). Dose values were calculated from the dose length product provided in the patient protocol/dose reports, Monte Carlo simulations were performed to assess dose distribution for CPM and HPM. all scans were performed without complications. Image quality was superior with HPM, because of a significant reduction in motion artifacts, as compared to CPM with 10- and 64-slice CT. In the control group, artifacts were encountered at the level of the diaphragm (n = 30; 100%), the borders of the heart (n = 30; 100%), and the ribs (n = 20; 67%) and spine (n = 6; 20%), whereas motion artifacts were detected in the HPM-group only in 6 patients in the lung parenchyma next to the diaphragm or the heart (P detector width and pitch-value. high-pitch chest CT is a robust method to provide highest image quality making sedation

  18. Clinical chest CAD system for lung cancer, COPD, and osteoporosis based on MDCT images

    International Nuclear Information System (INIS)

    Matsuhiro, Mikio; Suzuki, Hidenobu; Saita, Shinsuke

    2011-01-01

    Lung cancer kills more people than any other cancer worldwide. Lung cancer screening using low-dose CT have been performed in many countries. Comparative reading of current and past CT images is important for evaluation of pulmonary nodules in lung cancer CT screening. However, primary problem in comparative reading is mismatch of slice and nodule positions caused by lung variation. It is hard for physicians to manually match slice positions, nodule positions, and evaluate the nodule's degree of change. A system to assist smooth comparative reading is necessary. We proposed a comparative reading system for lung cancer CT screening. A distinctive feature is highly accurate matching method of region of interest based on thoracic organs registration. Pulmonary blood vessels registration using analysis of the tree structure is performed. The system is evaluated by 1 mm and 2 mm slice thickness CT images obtained from lung cancer CT screening. We show how it is useful for lung cancer CT screening. (author)

  19. Roentgen signs in diagnostic imaging. Vol. 4/1: The chest. Pt. 1

    International Nuclear Information System (INIS)

    Meschan, I.; Farrer-Meschan, R.M.

    1991-01-01

    This first part of two of the volume on biomedical radiography of the thorax primarily deals with the roentgenography of the body regions and organs mentioned in the title augmentation. Chapters: Introduction. Patient positioning, projections, pathological findings, terminology. Chaper 1, Upper respiratory tract and lungs. Chapter 2, Radiography of the diaphragm, pleura, the osseous thorax, and the upper respiratory tract (excluding the larynx). Chapter 3, Mammography. Chapter 4, Laryngography. Chapter 5, Radiographic signs of pathological changes in the lungs - a survey. Chapter 6, Radiographic signs of respiratory illness in newborns, infants and children. Chapter 7, Unsharp, homogenous shadows in the lung parenchyma. Chapter 8, Roentgendiagnosis of round foci in the lung. Chapter 9, Linear and reticular lung shadows. Chapter 10, Diffuse and focal changes of the lung parenchyma with enhanced radiolucency. Non-roentgenographic imaging methods, such as CT, NMR imaging or nuclear medicine, are discussed only occasionally. (orig./MG) With 1590 figs., 61 tabs [de

  20. Roentgen signs in diagnostic imaging. Vol. 4/2: The chest. Pt. 2

    International Nuclear Information System (INIS)

    Meschan, I.; Farrer-Meschan, R.M.

    1991-01-01

    This second part of two of the volume on biomedical radiography of the thorax primarily deals with the roentgenography of the body regions and organs mentioned in the title augmentation. There are the following chapters: 1. Medistinal and hilary deviations from standard (excluding the heart and large coronary vessels). 2. Radiography of the heart and the large coronary vessels. 3. Interpretation of plain radiographs of connatal anomalies of the heart and the large coronary vessels. 4. Examples of magnetic resonance images of connatal heart and coronary vessel anomalies. Other, non-roentgenographic imaging techniques, as CT, NMR tomography, and nuclear medicine, are dealt with only occasionally. (orig./MG) With 760 figs., 19 tabs [de

  1. Radiation levels and image quality in patients undergoing chest X-ray examinations

    Science.gov (United States)

    de Oliveira, Paulo Márcio Campos; do Carmo Santana, Priscila; de Sousa Lacerda, Marco Aurélio; da Silva, Teógenes Augusto

    2017-11-01

    Patient dose monitoring for different radiographic procedures has been used as a parameter to evaluate the performance of radiology services; skin entrance absorbed dose values for each type of examination were internationally established and recommended aiming patient protection. In this work, a methodology for dose evaluation was applied to three diagnostic services: one with a conventional film and two with digital computerized radiography processing techniques. The x-ray beam parameters were selected and "doses" (specifically the entrance surface and incident air kerma) were evaluated based on images approved in European criteria during postero-anterior (PA) and lateral (LAT) incidences. Data were collected from 200 patients related to 200 PA and 100 LAT incidences. Results showed that doses distributions in the three diagnostic services were very different; the best relation between dose and image quality was found in the institution with the chemical film processing. This work contributed for disseminating the radiation protection culture by emphasizing the need of a continuous dose reduction without losing the quality of the diagnostic image.

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... Imaging (MRI) - Chest Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  3. Chest X-Ray

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  4. Clinical evaluation of adenosine and exercise stress 99Tcm-MIBI myocardial imaging in detection of myocardial ischemia in patients with untypical chest pain

    International Nuclear Information System (INIS)

    Tian Yueqin; He Zuoxiang; Wang Qi; Hu Fenghuan; Yang Weixian; Qiao Shubing; Liu Xiujie

    2005-01-01

    Objective: To evaluate the value of adenosine and exercise stress 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial imaging for the diagnosis of myocardial ischemia in patients with untypical chest pain. Methods: Two groups included. Group 1: 67 cases of adenosine 99 Tc m -MIBI myocardial imaging. Group 2: 81 cases of exercise stress 99 Tc m -MIBI myocardial imaging. All of the patients had coronary angiography (CAG). The results of them were compared. Results: 23 out of 67 patients in group 1 had significant coronary stenosis after CAG, 16 showed reversible perfusion abnormalities in adenosine imaging. 41 of 44 patients with normal CAG showed normal adenosine imaging. The sensitivity, specificity and accuracy of adenosine imaging for coronary artery disease detection were 70%, 93% and 85%, respectively. Group 2: 22 out of 31 patients with significant coronany stenosis after CAG showed reversible perfusion abnormalities, 48 of 50 patients with normal CAG showed normal exercise imaging. The sensitivity, specificity and accuracy of exercise imaging for coronary artery disease detection were 71%, 96% and 86%, respectively. Conclusion: Reversible perfusion abnormalities found both in adenosine and exercise stress 99 Tc m -MIBI myocardial imaging were the key point for diagnosis of myocardial ischemia in patients with untypical chest pain. (authors)

  5. 99mTc-Tetrofosmin scintimammography in suspected breast cancer patients: comparison with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate the diagnostic role of 99m Tc-Tetrofosmin in detection of breast cancer and compared with that of 99m Tc-MIBI. Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had 99m Tc-MIBI and 99m Tc-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of 99m Tc-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-Tetrofosmin were 31, 10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of 99m Tc-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both 99m Tc-Tetrofosmin scintimammographies and its size was 0.5cm. 99m Tc-Tetrofosmin and 99m Tc-MIBI were non-invasive and useful in detection of breast cancer and 99m Tc-Tetrofosmin was comparable to the 99m Tc-MIBI in detection of primary breast cancer.=20

  6. Scintigraphic study of palpable breast nodes with 99m Tc-tetrofosmin

    International Nuclear Information System (INIS)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da; Amarante Junior, Jose Luiz de Medeiros; Fabricio, Maria Ines Menescal

    1998-01-01

    In Brazil, breast carcinoma has the greater incidence among women. In 1996, about 31,210 new cases were diagnosed. The purpose of this study is to determine if 99m technetium-tetrofosmin preferentially concentrates within malignant palpable breast nodes, distinguishing them from the benign lumps. Fifth-four consecutive and unsolicited women, mean age 47.5 +- 10.7 years, with palpable nodes in breast, underwent breast scintigraphy with 99m technetium-tetrofosmin and excisional biopsy or fine needle puncture within interval eight weeks. Histopathologic studies demonstrated 13 cysts, 1 cyst with local inflammation, 11 fibroadenoma, 2 fibrodysplasias, 3 fibroadenomas with high cellularity, 1 fibrocystic change with local inflammation, 23 invasive intraductal carcinomas and 1 invasive lobular carcinoma. The nodes ranged from 10 to 100 mm in greater diameter. The scintigraphic study yielded 30 true-negative cases, 24 true-positives, no false-negative and 1 false-positive. This case was a fibrocystic lump with local inflammation. Two patients had metastases in axillary lymph nodes, well detected in scintigraphy. The statistic analysis showed: sensitivity, 100%; specificity, 96.8%; accuracy, 98.2%; negative predictive value, 100%; positive predictive value, 96.0%. Nonparametric tests of Fisher and Chi-square rejected the antithesis at a confidence interval of 99.9% (p 99m technetium-tetrofosmin preferentially concentrates in malignant palpable breast nodes and can help to distinguish them from the benign tumors with with very high accuracy. (author)

  7. Comparison of image quality among three x-ray systems for chest radiography: first step in optimisation

    International Nuclear Information System (INIS)

    Nocetti, D.; Ubeda, C.; Calcagno, S.; Acevedo, J.; Pardo, D.

    2015-01-01

    The aim of this study was to compare the performance of three digital X-ray systems [one flat-panel (DR) and two computed radiography (CR)] for chest radiography in terms of the entrance surface air kerma (ESAK) delivered to a polymethyl methacrylate phantom of 20 cm (equivalent to an adult patient) and image quality through of numerical evaluations using a test object (TO). The tube charge applied was ranged from 0.6 to 32 mAs, to a fixed tension of 125 kVp. The DR system presented the highest mean values of ESAK (615.9 μGy) along with the highest signal-to-noise ratio values, whereas CR systems showed a better high-contrast spatial resolution. Differences were statistically significant in both cases regarding the tube charge used. Thus, this parameter should be mainly considered to optimise the radiological protection through exposure settings selected. This survey represents the first effort to achieve optimisation in digital radiology for Chile. (authors)

  8. Prognostic Value of Coronary Artery Calcium in the PROMISE Study (Prospective Multicenter Imaging Study for Evaluation of Chest Pain).

    Science.gov (United States)

    Budoff, Matthew J; Mayrhofer, Thomas; Ferencik, Maros; Bittner, Daniel; Lee, Kerry L; Lu, Michael T; Coles, Adrian; Jang, James; Krishnam, Mayil; Douglas, Pamela S; Hoffmann, Udo

    2017-11-21

    Coronary artery calcium (CAC) is an established predictor of future major adverse atherosclerotic cardiovascular events in asymptomatic individuals. However, limited data exist as to how CAC compares with functional testing (FT) in estimating prognosis in symptomatic patients. In the PROMISE trial (Prospective Multicenter Imaging Study for Evaluation of Chest Pain), patients with stable chest pain (or dyspnea) and intermediate pretest probability for obstructive coronary artery disease were randomized to FT (exercise electrocardiography, nuclear stress, or stress echocardiography) or anatomic testing. We evaluated those who underwent CAC testing as part of the anatomic evaluation (n=4209) and compared that with results of FT (n=4602). We stratified CAC and FT results as normal or mildly, moderately, or severely abnormal (for CAC: 0, 1-99 Agatston score [AS], 100-400 AS, and >400 AS, respectively; for FT: normal, mild=late positive treadmill, moderate=early positive treadmill or single-vessel ischemia, and severe=large ischemic region abnormality). The primary end point was all-cause death, myocardial infarction, or unstable angina hospitalization over a median follow-up of 26.1 months. Cox regression models were used to calculate hazard ratios (HRs) and C statistics to determine predictive and discriminatory values. Overall, the distribution of normal or mildly, moderately, or severely abnormal test results was significantly different between FT and CAC (FT: normal, n=3588 [78.0%]; mild, n=432 [9.4%]; moderate, n=217 [4.7%]; severe, n=365 [7.9%]; CAC: normal, n=1457 [34.6%]; mild, n=1340 [31.8%]; moderate, n=772 [18.3%]; severe, n=640 [15.2%]; P 0), whereas fewer than half of events occurred in patients with mildly, moderately, or severely abnormal FT (n=57 of 132, 43%; P fair for both CAC and FT (C statistic, 0.67 versus 0.64). Coronary computed tomographic angiography provided significantly better prognostic information compared with FT and CAC testing (C index

  9. A study on image quality and exposure dose of hard radiation radiography of the chest

    International Nuclear Information System (INIS)

    Hayashi, Taro; Ishida, Yuji; Maeda, Mika; Sakurai, Tatsuya; Kim, Chung Woon; Hwang, Jong Sun

    1991-01-01

    Experiment was conducted on the image quality and exposure dose following replacement of CaWO 4 system screen BH - III and BX - III which have so far been used for high - voltage hard - radiation quality radiography, with rare earth system screen KO750, combined with high contrast film SRH, while additional filter was altered, Cu 0.8 mm + Al 1.4 mm(HVL : AI 8.8 mm), Cu 1.3 mm + AI 1.0mm(HVL: AI 10.6mm) and Cu 1.8mm + AI 1.5mm(HVL: AI 11.4mm). AS a result, visual evaluation did not detect extreme changes in image quality under the respective condition (HVL : Al 8.8 mm ∼ AI 11.4 mm). It was noted, however, that surface exposure dose declined with an increase in the thickness of the additional filter, as it was 18.9 μGy at HVL Al 8.8 mm, 17.5 μGy at Al 10.6 mm and 15.7 μGy at Al 11.4 mm. Considering the limited rating of X-ray equipment and wear of machinery, however, the range of Cu 1.3 mm ∼ l.8 mm + AI 1.0 mm ∼ 1.5 mm(1/16 VL ∼ 1/32 VL) seemed to be a limit

  10. [Chest trauma].

    Science.gov (United States)

    Freixinet Gilart, Jorge; Ramírez Gil, María Elena; Gallardo Valera, Gregorio; Moreno Casado, Paula

    2011-01-01

    Chest trauma is a frequent problem arising from lesions caused by domestic and occupational activities and especially road traffic accidents. These injuries can be analyzed from distinct points of view, ranging from consideration of the most severe injuries, especially in the context of multiple trauma, to the specific characteristics of blunt and open trauma. In the present article, these injuries are discussed according to the involvement of the various thoracic structures. Rib fractures are the most frequent chest injuries and their diagnosis and treatment is straightforward, although these injuries can be severe if more than three ribs are affected and when there is major associated morbidity. Lung contusion is the most common visceral lesion. These injuries are usually found in severe chest trauma and are often associated with other thoracic and intrathoracic lesions. Treatment is based on general support measures. Pleural complications, such as hemothorax and pneumothorax, are also frequent. Their diagnosis is also straightforward and treatment is based on pleural drainage. This article also analyzes other complex situations, notably airway trauma, which is usually very severe in blunt chest trauma and less severe and even suitable for conservative treatment in iatrogenic injury due to tracheal intubation. Rupture of the diaphragm usually causes a diaphragmatic hernia. Treatment is always surgical. Myocardial contusions should be suspected in anterior chest trauma and in sternal fractures. Treatment is conservative. Other chest injuries, such as those of the great thoracic and esophageal vessels, are less frequent but are especially severe. Copyright © 2011 Sociedad Española de Neumología y Cirugía Torácica. Published by Elsevier Espana. All rights reserved.

  11. Comparison of uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mT-Q12 into human breast cancer cell lines

    International Nuclear Information System (INIS)

    Yong, M. de; Bernard, B.F.; Breeman, W.A.P.; Ensing, G.; Benjamins, H.; Bakker, W.H.; Visser, T.J.; Krenning, E.P.

    1996-01-01

    Technetium-99m hexakis-2-methoxyisobutyl-isonitrile (MIBI), 99m Tc-tetrofosmin and 99m Tc-Q12 were all introduced for myocardial imaging but found additional applications as they are taken up by different tumours, enabling imaging of these lesions in patients. The aim of this study was to compare the uptake characteristics of these compounds in vitro in the human adenocarcinoma breast cell lines MCF-7 and ZR-75. It was shown that 99m Tc-MIBI had the highest cellular uptake (15.9%±0.5% dose/mg protein after 60 min in MCF-7, and 14.2%±0.4% dose/mg protein in ZR-75), followed by 99m Tc-tetrofosmin (6.8%±0.6% dose/mg protein in MCF-7, and 8.2%±0.2% dose/mg protein in ZR-75) and 99m TC-Q12 (3.2%±0.1% dose/mg protein in MCF-7, and 3.5%±0.3% dose/mg protein in ZR-75 cells). For all three compounds tenfold differences in specific activity did not influence total cell-associated radioactivity. Uptake of 99m Tc-MIBI and 99m Tc-tetrofosmin was obviously lower at 4 C than at 37 C, whereas 99m Tc-Q12 uptake showed only slight temperature dependence. When uptake was compared in cells grown to different cell densities (1 mg/ml cellular protein versus 0.3 mg/ml), no differences in uptake were detected when uptake was corrected for the amount of cellular protein present in the dishes. Furthermore, for all compounds it was shown that cellular radioactivity decreased rapidly after washing. Apart from the differences in cellular uptake of the three compounds after 60 min, no differences in residual cellular radioactivity after washing were found between the different compounds when expressed as a percentage of their 60-min uptake, suggesting that the efflux process of the radiolabelled compounds was similar. The differences in cell-associated activity after 60 min were thus presumably caused by differences in uptake. (orig./MG)

  12. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  13. Chest pain

    International Nuclear Information System (INIS)

    Martinez A, Juan Carlos; Saenz M, Oscar; Martinez M, Camilo; Gonzales A Francisco; Nicolas R, Jose; Vergara V, Erika P; Pereira G, Alberto M

    2010-01-01

    In emergency departments, chest pain is one of the leading motives of consultation. We thus consider it important to review aspects such as its classification, causes, and clinical profiles. Initial assessment should include a full clinical history comprising thorough anamnesis and physical examination. Adequate interpretation of auxiliary tests, ordered in accordance with suspected clinical conditions, should lead to accurate diagnosis. We highlight certain symptoms and clinical signs, ECG and X-ray findings, cardiac bio markers, arterial blood gases, and CT-scanning. Scores of severity and prognosis such as TIMI are assessed. Optimal treatment of the clinical conditions leading to chest pain depends on adequate initial approach and assessment.

  14. Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 11: Quantification of chest wall motion during deep inspiration breast hold treatments using cine EPID images and a physics based algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Alpuche Aviles, Jorge E.; VanBeek, Timothy [CancerCare Manitoba, Winnipeg (Canada); Sasaki, David; Rivest, Ryan; Akra, Mohamed [CancerCare Manitoba, Winnipeg (Canada); University of Manitoba, Winnipeg (Canada)

    2016-08-15

    Purpose: This work presents an algorithm used to quantify intra-fraction motion for patients treated using deep inspiration breath hold (DIBH). The algorithm quantifies the position of the chest wall in breast tangent fields using electronic portal images. Methods: The algorithm assumes that image profiles, taken along a direction perpendicular to the medial border of the field, follow a monotonically and smooth decreasing function. This assumption is invalid in the presence of lung and can be used to calculate chest wall position. The algorithm was validated by determining the position of the chest wall for varying field edge positions in portal images of a thoracic phantom. The algorithm was used to quantify intra-fraction motion in cine images for 7 patients treated with DIBH. Results: Phantom results show that changes in the distance between chest wall and field edge were accurate within 0.1 mm on average. For a fixed field edge, the algorithm calculates the position of the chest wall with a 0.2 mm standard deviation. Intra-fraction motion for DIBH patients was within 1 mm 91.4% of the time and within 1.5 mm 97.9% of the time. The maximum intra-fraction motion was 3.0 mm. Conclusions: A physics based algorithm was developed and can be used to quantify the position of chest wall irradiated in tangent portal images with an accuracy of 0.1 mm and precision of 0.6 mm. Intra-fraction motion for patients treated with DIBH at our clinic is less than 3 mm.

  15. Evolution of Entrance Surface Doses and Image Quality in Pediatric Chest Radiographs

    International Nuclear Information System (INIS)

    Campello, A.C.; Marques, D.T.; Medeiros, C.B.; Carvalho, P.P.; Khoury, H.J.; Azevedo, A.C.P.

    2006-01-01

    This work presents the results of a survey about image quality, radiographic techniques and patient doses in a large public hospital located in the city of Recife, Brazil. It was detected that the quality criteria are not fully reached and represent 70% of the agreement with recommendations from the European Community. Concerning the radiographic techniques the kV is in accordance with international recommendations in 90% if the examinations while the exposure time is 72%. The results also show that the dose values change in the range from 0.020 to 0.250 mGy. The variability is mainly caused by the disparity on the radiographic techniques employed in the examinations as well as by the radiographer's expertise. It could be concluded that the ALARA principle is not being applied in the hospital, which becomes a concern in terms of public health. (author)

  16. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial

    International Nuclear Information System (INIS)

    Montz, R.; Perez-Castejon, M.J.; Jurado, J.A.; Martin-Comin, J.; Esplugues, E.; Salgado, L.; Ventosa, A.; Cantinho, G.; Sa, E.P.; Fonseca, A.T.; Vieira, M.R.; Ortiz-Berrocal, J.; Magrina, J.; Ortega, D.; Puente, C.; Ferrer, A.I.; Pedrosa, J.; Latre, J.M.; Carreras, J.L.

    1996-01-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with ≤300 MBq 99m Tc-tetrofosmin at rest and ≤900 MBq approximately 1 h later at peak exercise. Single-photon emission tomographic (SPET) acquisitions were initiated within 5-30 min post injection. The results were compared with those of coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%. The localization of defects by SPET in relation the perfusion territories of stenosed vessels (≥=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99m Tc terofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h). (orig.)

  17. The impact of an early-morning radiologist work shift on the timeliness of communicating urgent imaging findings on portable chest radiography.

    Science.gov (United States)

    Kaewlai, Rathachai; Greene, Reginald E; Asrani, Ashwin V; Abujudeh, Hani H

    2010-09-01

    The aim of this study was to assess the potential impact of staggered radiologist work shifts on the timeliness of communicating urgent imaging findings that are detected on portable overnight chest radiography of hospitalized patients. The authors conducted a retrospective study that compared the interval between the acquisition and communication of urgent findings on portable overnight critical care chest radiography detected by an early-morning shift for radiologists (3 am to 11 am) with historical experience with a standard daytime shift (8 am to 5 pm) in the detection and communication of urgent findings in a similar patient population a year earlier. During a 4-month period, 6,448 portable chest radiographic studies were interpreted on the early-morning radiologist shift. Urgent findings requiring immediate communication were detected in 308 (4.8%) studies. The early-morning shift of radiologists, on average, communicated these findings 2 hours earlier compared with the historical control group (P chest radiography of hospitalized patients. Published by Elsevier Inc.

  18. Automatic system for quantification and visualization of lung aeration on chest computed tomography images: the Lung Image System Analysis - LISA

    Energy Technology Data Exchange (ETDEWEB)

    Felix, John Hebert da Silva; Cortez, Paulo Cesar, E-mail: jhsfelix@gmail.co [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Dept. de Engenharia de Teleinformatica; Holanda, Marcelo Alcantara [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Hospital Universitario Walter Cantidio. Dept. de Medicina Clinica

    2010-12-15

    High Resolution Computed Tomography (HRCT) is the exam of choice for the diagnostic evaluation of lung parenchyma diseases. There is an increasing interest for computational systems able to automatically analyze the radiological densities of the lungs in CT images. The main objective of this study is to present a system for the automatic quantification and visualization of the lung aeration in HRCT images of different degrees of aeration, called Lung Image System Analysis (LISA). The secondary objective is to compare LISA to the Osiris system and also to specific algorithm lung segmentation (ALS), on the accuracy of the lungs segmentation. The LISA system automatically extracts the following image attributes: lungs perimeter, cross sectional area, volume, the radiological densities histograms, the mean lung density (MLD) in Hounsfield units (HU), the relative area of the lungs with voxels with density values lower than -950 HU (RA950) and the 15th percentile of the least density voxels (PERC15). Furthermore, LISA has a colored mask algorithm that applies pseudo-colors to the lung parenchyma according to the pre-defined radiological density chosen by the system user. The lungs segmentations of 102 images of 8 healthy volunteers and 141 images of 11 patients with Chronic Obstructive Pulmonary Disease (COPD) were compared on the accuracy and concordance among the three methods. The LISA was more effective on lungs segmentation than the other two methods. LISA's color mask tool improves the spatial visualization of the degrees of lung aeration and the various attributes of the image that can be extracted may help physicians and researchers to better assess lung aeration both quantitatively and qualitatively. LISA may have important clinical and research applications on the assessment of global and regional lung aeration and therefore deserves further developments and validation studies. (author)

  19. Automatic system for quantification and visualization of lung aeration on chest computed tomography images: the Lung Image System Analysis - LISA

    International Nuclear Information System (INIS)

    Felix, John Hebert da Silva; Cortez, Paulo Cesar; Holanda, Marcelo Alcantara

    2010-01-01

    High Resolution Computed Tomography (HRCT) is the exam of choice for the diagnostic evaluation of lung parenchyma diseases. There is an increasing interest for computational systems able to automatically analyze the radiological densities of the lungs in CT images. The main objective of this study is to present a system for the automatic quantification and visualization of the lung aeration in HRCT images of different degrees of aeration, called Lung Image System Analysis (LISA). The secondary objective is to compare LISA to the Osiris system and also to specific algorithm lung segmentation (ALS), on the accuracy of the lungs segmentation. The LISA system automatically extracts the following image attributes: lungs perimeter, cross sectional area, volume, the radiological densities histograms, the mean lung density (MLD) in Hounsfield units (HU), the relative area of the lungs with voxels with density values lower than -950 HU (RA950) and the 15th percentile of the least density voxels (PERC15). Furthermore, LISA has a colored mask algorithm that applies pseudo-colors to the lung parenchyma according to the pre-defined radiological density chosen by the system user. The lungs segmentations of 102 images of 8 healthy volunteers and 141 images of 11 patients with Chronic Obstructive Pulmonary Disease (COPD) were compared on the accuracy and concordance among the three methods. The LISA was more effective on lungs segmentation than the other two methods. LISA's color mask tool improves the spatial visualization of the degrees of lung aeration and the various attributes of the image that can be extracted may help physicians and researchers to better assess lung aeration both quantitatively and qualitatively. LISA may have important clinical and research applications on the assessment of global and regional lung aeration and therefore deserves further developments and validation studies. (author)

  20. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT.

    Science.gov (United States)

    Cho, S H; Sung, Y M; Kim, M S

    2012-10-01

    The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.

  1. PROspective Multicenter Imaging Study for Evaluation of chest pain: rationale and design of the PROMISE trial.

    Science.gov (United States)

    Douglas, Pamela S; Hoffmann, Udo; Lee, Kerry L; Mark, Daniel B; Al-Khalidi, Hussein R; Anstrom, Kevin; Dolor, Rowena J; Kosinski, Andrzej; Krucoff, Mitchell W; Mudrick, Daniel W; Patel, Manesh R; Picard, Michael H; Udelson, James E; Velazquez, Eric J; Cooper, Lawton

    2014-06-01

    Suspected coronary artery disease (CAD) is one of the most common, potentially life-threatening diagnostic problems clinicians encounter. However, no large outcome-based randomized trials have been performed to guide the selection of diagnostic strategies for these patients. The PROMISE study is a prospective, randomized trial comparing the effectiveness of 2 initial diagnostic strategies in patients with symptoms suspicious for CAD. Patients are randomized to either (1) functional testing (exercise electrocardiogram, stress nuclear imaging, or stress echocardiogram) or (2) anatomical testing with ≥64-slice multidetector coronary computed tomographic angiography. Tests are interpreted locally in real time by subspecialty certified physicians, and all subsequent care decisions are made by the clinical care team. Sites are provided results of central core laboratory quality and completeness assessment. All subjects are followed up for ≥1 year. The primary end point is the time to occurrence of the composite of death, myocardial infarction, major procedural complications (stroke, major bleeding, anaphylaxis, and renal failure), or hospitalization for unstable angina. More than 10,000 symptomatic subjects were randomized in 3.2 years at 193 US and Canadian cardiology, radiology, primary care, urgent care, and anesthesiology sites. Multispecialty community practice enrollment into a large pragmatic trial of diagnostic testing strategies is both feasible and efficient. The PROMISE trial will compare the clinical effectiveness of an initial strategy of functional testing against an initial strategy of anatomical testing in symptomatic patients with suspected CAD. Quality of life, resource use, cost-effectiveness, and radiation exposure will be assessed. Copyright © 2014 Mosby, Inc. All rights reserved.

  2. Clinical application of 99Tcm-tetrofosmin in diagnosis patients with coronary heart disease

    International Nuclear Information System (INIS)

    Li Na; Chen Song; Wang Xiaobei; Wang Ying; Yin Yafu; Li Xuena; Li Yaming; Wang Lijuan; He Zuoxiang

    2012-01-01

    Objective: To evaluate the diagnostic value of 99 Tc m -tetrofosmin(TF) stress-rest MPI in detecting CHD. Methods: Eighty patients with suspected CHD who had stress-rest MPI from October 2009 to April 2011 were retrospectively analyzed.Forty underwent 99 Tc m -TF (group A) and 40 received 99 Tc m -MIBI (group B) stress-rest MPI. Heart/lung (H/L) ratios of these two groups were compared.CAG was performed on group A patients 3 months before and after MPI. Stenosis of more than 50% in CAG was used as a standard to evaluate the diagnostic efficiency of 99 Tc m -TF MPI. Paired t test and χ 2 test were used to compare the data. Results: H/L ratios of rest and stress from 99 Tc m -TF images were 6.73 ± 1.21 and 6.94 ± 1.69, while those from 99 Tc m -MIBI images were 6.58 ± 1.94 and 6.64 ± 1.81, respectively. There was no difference between 99 Tc m -TF and 99 Tc m -MIBI imaging in both rest and stress (t=0.41, 0.78, both P>0.05). There was no difference between H/L ratios from stress and rest 99 Tc m -TF imaging (t=0.69, P >0.05). Twenty-four patients who underwent 99 Tc m -TF imaging had abnormal perfusion (60.0%, 24/40), including 20 LAD, 11 LCX and 14 RCA. Twenty-three among these 40 patients had abnormal CAG results (57.5%, 23/40), including 19 LAD, 12 LCX, and 11 RCA. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of 99 Tc m -TF stress-rest MPI were 87.0% (20/23), 76.5% (13/17), 82.5% (33/40), 83.3% (20/24) and 81.2% (13/16), respectively. The sensitivities of 99 Tc m -TF stress-rest MPI for detection of LAD, LCX and RCA were 89.5% (17/19), 83.3% (10/12) and 90.9% (10/11), respectively,and positive predictive values were 85.0% (17/20), 90.9% (10/11) and 71.4% (10/14), respectively. There was no significant difference for sensitivity and positive predictive value of 99 Tc m -TF MPI among different vessels (χ 2 =0.377 and 1.789, both P>0.05). Conclusions: 99 Tc m -TF MPI has comparative imaging quality to 99 Tc m

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... talk with you about chest radiography also known as chest x-rays. Chest x-rays are the ... treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray ...

  4. New released DR detector (Canon CXDI 70C wireless) tested at premature neonates chest examination focusing on dose and image quality

    DEFF Research Database (Denmark)

    Precht, Helle

    2011-01-01

    maintaining image quality - in accordance with the ALARA principle. Dose reduction is particularly interesting in paediatrics because of the high radiation sensitivity of children. In preterm, a dose reduction has even greater importance, and because the anatomical structures in the chest are extra small...... Carlo and analyzed in conjunction with exposure index values. Statistical analysis supported the results. Results The IQF value from the technical phantom is clearly higher at the new detector at all exposure values as well as the VGA shows great potential for improving image quality and possibilities...

  5. Ultrasonography of chest wall lesion

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol Min; Kim, C. H.; Cha, I. H.; Chung, K. B.; Ser, W. H.; Choi, Y. H. [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    Thirty-one patients with chest wall diseases were studied with ultrasound to evaluate its role in chest wall lesions. There were eight infectious conditions, 9 benign tumors, 11 malignant lesions and 3 miscellaneous cases. Diffuse chest wall thickening with heterogeneous echogenicity and obliteration of subcutaneous fat layer are findings of acute infection. In cases of tuberculous smpyema necessitates, pleural abnormality extended to the chest wall through intercostal space. Benign tumors were well demarcated, except in 4 cases of lipoma/lipomatosis. Malignant lesions showed irregular soft tissue masses, bone destruction, pleural effusion and subcutaneous invasion. Multiple enlarged lymph nodes were also shown. Ultrasound can demonstrate te internal structure, extent, depth and associated findings such as pleural effusion, bone destruction and peripheral lung involvement. Ultrasound is not only safe, non-invasive and an effective diagnostic imaging modality for chest wall disease, but can also guide aspiration or biopsy for pathologic diagnosis

  6. Ultrasonography of chest wall lesion

    International Nuclear Information System (INIS)

    Park, Cheol Min; Kim, C. H.; Cha, I. H.; Chung, K. B.; Ser, W. H.; Choi, Y. H.

    1989-01-01

    Thirty-one patients with chest wall diseases were studied with ultrasound to evaluate its role in chest wall lesions. There were eight infectious conditions, 9 benign tumors, 11 malignant lesions and 3 miscellaneous cases. Diffuse chest wall thickening with heterogeneous echogenicity and obliteration of subcutaneous fat layer are findings of acute infection. In cases of tuberculous smpyema necessitates, pleural abnormality extended to the chest wall through intercostal space. Benign tumors were well demarcated, except in 4 cases of lipoma/lipomatosis. Malignant lesions showed irregular soft tissue masses, bone destruction, pleural effusion and subcutaneous invasion. Multiple enlarged lymph nodes were also shown. Ultrasound can demonstrate te internal structure, extent, depth and associated findings such as pleural effusion, bone destruction and peripheral lung involvement. Ultrasound is not only safe, non-invasive and an effective diagnostic imaging modality for chest wall disease, but can also guide aspiration or biopsy for pathologic diagnosis

  7. An automated patient recognition method based on an image-matching technique using previous chest radiographs in the picture archiving and communication system environment

    International Nuclear Information System (INIS)

    Morishita, Junji; Katsuragawa, Shigehiko; Kondo, Keisuke; Doi, Kunio

    2001-01-01

    An automated patient recognition method for correcting 'wrong' chest radiographs being stored in a picture archiving and communication system (PACS) environment has been developed. The method is based on an image-matching technique that uses previous chest radiographs. For identification of a 'wrong' patient, the correlation value was determined for a previous image of a patient and a new, current image of the presumed corresponding patient. The current image was shifted horizontally and vertically and rotated, so that we could determine the best match between the two images. The results indicated that the correlation values between the current and previous images for the same, 'correct' patients were generally greater than those for different, 'wrong' patients. Although the two histograms for the same patient and for different patients overlapped at correlation values greater than 0.80, most parts of the histograms were separated. The correlation value was compared with a threshold value that was determined based on an analysis of the histograms of correlation values obtained for the same patient and for different patients. If the current image is considered potentially to belong to a 'wrong' patient, then a warning sign with the probability for a 'wrong' patient is provided to alert radiology personnel. Our results indicate that at least half of the 'wrong' images in our database can be identified correctly with the method described in this study. The overall performance in terms of a receiver operating characteristic curve showed a high performance of the system. The results also indicate that some readings of 'wrong' images for a given patient in the PACS environment can be prevented by use of the method we developed. Therefore an automated warning system for patient recognition would be useful in correcting 'wrong' images being stored in the PACS environment

  8. Attenuation-based automatic kilovolt (kV)-selection in computed tomography of the chest: Effects on radiation exposure and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael [Department of Radiology, University Erlangen (Germany); Achenbach, Stephan [Department of Cardiology, University Erlangen (Germany); Uder, Michael [Department of Radiology, University Erlangen (Germany); Imaging Science Institute, Erlangen (Germany); Lell, Michael M., E-mail: Michael.lell@uk-erlangen.de [Department of Radiology, University Erlangen (Germany); Imaging Science Institute, Erlangen (Germany)

    2013-12-01

    Objectives: To evaluate an automated attenuation-based kV-selection in computed tomography of the chest in respect to radiation dose and image quality, compared to a standard 120 kV protocol. Materials and methods: 104 patients were examined using a 128-slice scanner. Fifty examinations (58 ± 15 years, study group) were performed using the automated adaption of tube potential (100–140 kV), based on the attenuation profile of the scout scan, 54 examinations (62 ± 14 years, control group) with fixed 120 kV. Estimated CT dose index (CTDI) of the software-proposed setting was compared with a 120 kV protocol. After the scan CTDI volume (CTDIvol) and dose length product (DLP) were recorded. Image quality was assessed by region of interest (ROI) measurements, subjective image quality by two observers with a 4-point scale (3 – excellent, 0 – not diagnostic). Results: The algorithm selected 100 kV in 78% and 120 kV in 22%. Overall CTDIvol reduction was 26.6% (34% in 100 kV) overall DLP reduction was 22.8% (32.1% in 100 kV) (all p < 0.001). Subjective image quality was excellent in both groups. Conclusion: The attenuation based kV-selection algorithm enables relevant dose reduction (∼27%) in chest-CT while keeping image quality parameters at high levels.

  9. Attenuation-based automatic kilovolt (kV)-selection in computed tomography of the chest: Effects on radiation exposure and image quality

    International Nuclear Information System (INIS)

    Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael; Achenbach, Stephan; Uder, Michael; Lell, Michael M.

    2013-01-01

    Objectives: To evaluate an automated attenuation-based kV-selection in computed tomography of the chest in respect to radiation dose and image quality, compared to a standard 120 kV protocol. Materials and methods: 104 patients were examined using a 128-slice scanner. Fifty examinations (58 ± 15 years, study group) were performed using the automated adaption of tube potential (100–140 kV), based on the attenuation profile of the scout scan, 54 examinations (62 ± 14 years, control group) with fixed 120 kV. Estimated CT dose index (CTDI) of the software-proposed setting was compared with a 120 kV protocol. After the scan CTDI volume (CTDIvol) and dose length product (DLP) were recorded. Image quality was assessed by region of interest (ROI) measurements, subjective image quality by two observers with a 4-point scale (3 – excellent, 0 – not diagnostic). Results: The algorithm selected 100 kV in 78% and 120 kV in 22%. Overall CTDIvol reduction was 26.6% (34% in 100 kV) overall DLP reduction was 22.8% (32.1% in 100 kV) (all p < 0.001). Subjective image quality was excellent in both groups. Conclusion: The attenuation based kV-selection algorithm enables relevant dose reduction (∼27%) in chest-CT while keeping image quality parameters at high levels

  10. The Potential Role of Grid-Like Software in Bedside Chest Radiography in Improving Image Quality and Dose Reduction: An Observer Preference Study.

    Science.gov (United States)

    Ahn, Su Yeon; Chae, Kum Ju; Goo, Jin Mo

    2018-01-01

    To compare the observer preference of image quality and radiation dose between non-grid, grid-like, and grid images. Each of the 38 patients underwent bedside chest radiography with and without a grid. A grid-like image was generated from a non-grid image using SimGrid software (Samsung Electronics Co. Ltd.) employing deep-learning-based scatter correction technology. Two readers recorded the preference for 10 anatomic landmarks and the overall appearance on a five-point scale for a pair of non-grid and grid-like images, and a pair of grid-like and grid images, respectively, which were randomly presented. The dose area product (DAP) was also recorded. Wilcoxon's rank sum test was used to assess the significance of preference. Both readers preferred grid-like images to non-grid images significantly ( p software significantly improved the image quality of non-grid images to a level comparable to that of grid images with a relatively lower level of radiation exposure.

  11. Development of a prototype chest digital tomosynthesis (CDT) R/F system with fast image reconstruction using graphics processing unit (GPU) programming

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sunghoon, E-mail: choi.sh@yonsei.ac.kr [Department of Radiological Science, College of Health Science, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 220-710 (Korea, Republic of); Lee, Seungwan [Department of Radiological Science, College of Medical Science, Konyang University, 158 Gwanjeodong-ro, Daejeon, 308-812 (Korea, Republic of); Lee, Haenghwa [Department of Radiological Science, College of Health Science, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 220-710 (Korea, Republic of); Lee, Donghoon; Choi, Seungyeon [Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 220-710 (Korea, Republic of); Shin, Jungwook [LISTEM Corporation, 94 Donghwagongdan-ro, Munmak-eup, Wonju (Korea, Republic of); Seo, Chang-Woo [Department of Radiological Science, College of Health Science, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 220-710 (Korea, Republic of); Kim, Hee-Joung, E-mail: hjk1@yonsei.ac.kr [Department of Radiological Science, College of Health Science, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 220-710 (Korea, Republic of); Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 220-710 (Korea, Republic of)

    2017-03-11

    Digital tomosynthesis offers the advantage of low radiation doses compared to conventional computed tomography (CT) by utilizing small numbers of projections (~80) acquired over a limited angular range. It produces 3D volumetric data, although there are artifacts due to incomplete sampling. Based upon these characteristics, we developed a prototype digital tomosynthesis R/F system for applications in chest imaging. Our prototype chest digital tomosynthesis (CDT) R/F system contains an X-ray tube with high power R/F pulse generator, flat-panel detector, R/F table, electromechanical radiographic subsystems including a precise motor controller, and a reconstruction server. For image reconstruction, users select between analytic and iterative reconstruction methods. Our reconstructed images of Catphan700 and LUNGMAN phantoms clearly and rapidly described the internal structures of phantoms using graphics processing unit (GPU) programming. Contrast-to-noise ratio (CNR) values of the CTP682 module of Catphan700 were higher in images using a simultaneous algebraic reconstruction technique (SART) than in those using filtered back-projection (FBP) for all materials by factors of 2.60, 3.78, 5.50, 2.30, 3.70, and 2.52 for air, lung foam, low density polyethylene (LDPE), Delrin{sup ®} (acetal homopolymer resin), bone 50% (hydroxyapatite), and Teflon, respectively. Total elapsed times for producing 3D volume were 2.92 s and 86.29 s on average for FBP and SART (20 iterations), respectively. The times required for reconstruction were clinically feasible. Moreover, the total radiation dose from our system (5.68 mGy) was lower than that of conventional chest CT scan. Consequently, our prototype tomosynthesis R/F system represents an important advance in digital tomosynthesis applications.

  12. Diagnostic imaging costs before and after digital tomosynthesis implementation in patient management after detection of suspected thoracic lesions on chest radiography.

    Science.gov (United States)

    Quaia, Emilio; Grisi, Guido; Baratella, Elisa; Cuttin, Roberto; Poillucci, Gabriele; Kus, Sara; Cova, Maria Assunta

    2014-02-01

    To evaluate diagnostic imaging costs before and after DTS implementation in patients with suspected thoracic lesions on CXR. Four hundred sixty-five patients (263 male, 202 female; age, 72.47 ± 11.33 years) with suspected thoracic lesion(s) after CXR underwent DTS. Each patient underwent CT when a pulmonary non-calcified lesion was identified by DTS while CT was not performed when a benign pulmonary or extrapulmonary lesion or pseudolesion was identified. The average per-patient imaging cost was calculated by normalising the costs before and after DTS implementation. In 229/465 patients who underwent DTS after suspicious CXR, DTS showed 193 pulmonary lesions and 36 pleural lesions, while in the remaining 236/465 patients, lesions were ruled out as pseudolesions of CXR. Chest CT examination was performed in 127/465 (27 %) patients while in the remaining 338/465 patients (73 %) CXR doubtful findings were resolved by DTS. The average per-patient costs of CXR, DTS and CT were 15.15, 41.55 and 113.66. DTS allowed an annual cost saving of 8,090.2 considering unenhanced CT and 19,298.12 considering contrast-enhanced CT. Considering a DTS reimbursement rate of 62.7 the break even point corresponds to 479 DTS examinations. Per-patient diagnostic imaging costs decreased after DTS implementation in patients with suspected thoracic lesions. • Digital tomosynthesis improves the diagnostic accuracy and confidence in chest radiography • Digital tomosynthesis reduces the need for CT for a suspected pulmonary lesion • Digital tomosynthesis requires a dose level equivalent to that of around two chest radiographies • Digital tomosynthesis produces a significant per-patient saving in diagnostic imaging costs.

  13. Attenuation-based automatic kilovolt (kV)-selection in computed tomography of the chest: effects on radiation exposure and image quality.

    Science.gov (United States)

    Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael; Achenbach, Stephan; Uder, Michael; Lell, Michael M

    2013-12-01

    To evaluate an automated attenuation-based kV-selection in computed tomography of the chest in respect to radiation dose and image quality, compared to a standard 120 kV protocol. 104 patients were examined using a 128-slice scanner. Fifty examinations (58 ± 15 years, study group) were performed using the automated adaption of tube potential (100-140 kV), based on the attenuation profile of the scout scan, 54 examinations (62 ± 14 years, control group) with fixed 120 kV. Estimated CT dose index (CTDI) of the software-proposed setting was compared with a 120 kV protocol. After the scan CTDI volume (CTDIvol) and dose length product (DLP) were recorded. Image quality was assessed by region of interest (ROI) measurements, subjective image quality by two observers with a 4-point scale (3--excellent, 0--not diagnostic). The algorithm selected 100 kV in 78% and 120 kV in 22%. Overall CTDIvol reduction was 26.6% (34% in 100 kV) overall DLP reduction was 22.8% (32.1% in 100 kV) (all pimage quality was excellent in both groups. The attenuation based kV-selection algorithm enables relevant dose reduction (~27%) in chest-CT while keeping image quality parameters at high levels. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Chest radiography after minor chest trauma

    Energy Technology Data Exchange (ETDEWEB)

    Rossen, B.; Laursen, N.O.; Just, S.

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma.

  15. Regional improvement of signal-to-noise and contrast-to-noise ratios in dual-screen CR chest imaging - a phantom study

    International Nuclear Information System (INIS)

    Liu Xinming; Shaw, Chris C.

    2001-01-01

    The improvement of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in dual-screen computed radiography (CR) has been investigated for various regions in images of an anthropomorphic chest phantom. With the dual-screen CR technique, two image plates are placed in a cassette and exposed together during imaging. The exposed plates are separately scanned to form a front image and a back image, which are then registered and superimposed to form a composite image with improved SNRs and CNRs. The improvement can be optimized by applying specifically selected weighting factors during superimposition. In this study, dual-screen CR images of an anthropomorphic chest phantom were acquired and formed with four different combinations of standard resolution (ST) and high-resolution (HR) screens: ST-ST, ST-HR, HR-ST, and HR-HR. SNRs and their improvements were measured and compared over twelve representative regions-of-interest (ROIs) in these images. A 19.1%-45.7% increase of the SNR was observed, depending on the ROI and screen combination used. The optimal weighting factors were found to vary by only 4.5%-12.4%. Largest improvement was found in the lung field for all screen combinations. Improvement of CNRs was investigated over two ROIs in the lung field using the rib bones as the contrast objects and a 29.2%-43.9% improvement of the CNR was observed. Among the four screen combinations, ST-ST resulted in the most SNR and CNR improvement, followed in order by HR-ST, HR-HR, and ST-HR. The HR-ST combination yielded the lowest spatial variation of the optimal weighting factors with improved SNRs and CNRs close to those of the ST-ST combination

  16. Comparative effectiveness of coronary CT angiography vs stress cardiac imaging in patients following hospital admission for chest pain work-up: The Prospective First Evaluation in Chest Pain (PERFECT) Trial.

    Science.gov (United States)

    Uretsky, Seth; Argulian, Edgar; Supariwala, Azhar; Agarwal, Shiv K; El-Hayek, Georges; Chavez, Patricia; Awan, Hira; Jagarlamudi, Ashadevi; Puppala, Siva P; Cohen, Randy; Rozanski, Alan

    2017-08-01

    Because the frequency of cardiac event rates is low among chest pain patients following either performance of coronary CT angiography (CCTA) or stress testing, there is a need to better assess how these tests influence the central management decisions that follow from cardiac testing. The present study was performed to assess the relative impact of CCTA vs stress testing on medical therapies and downstream resource utilization among patients admitted for the work-up of chest pain. The admitted patients were randomized in a 1:1 ratio to either cardiac imaging stress test or CCTA. Primary outcomes were time to discharge, change in medication usage, and frequency of downstream testing, cardiac interventions, and cardiovascular re-hospitalizations. We randomized 411 patients, 205 to stress testing, and 206 to CCTA. There were no differences in time to discharge or initiation of new cardiac medications at discharge. At 1 year follow-up, there was no difference in the number of patients who underwent cardiovascular downstream tests in the CCTA vs stress test patients (21% vs 15%, P = .1) or cardiovascular hospitalizations (14% vs 16%, P = .5). However, there was a higher frequency of invasive angiography in the CCTA group (11% vs 2%, P = .001) and percutaneous coronary interventions (6% vs 0%, P work-up to either CCTA or to stress testing resulted in similar discharge times, change in medical therapies at discharge, frequency of downstream noninvasive testing, and repeat hospitalizations. However, a higher frequency of invasive coronary angiography and revascularization procedures were performed in the CCTA arm. (ClinicalTrials.gov number, NCT01604655.).

  17. Myocardial viability assessment with gated SPECT Tc-99m tetrofosmin % wall thickening. Comparison with F-18 FDG-PET

    International Nuclear Information System (INIS)

    Maruyama, Atsushi; Hasegawa, Shinji; Paul, A.K.; Xiuli, M.; Yoshioka, Jun; Maruyama, Kaoru; Hori, Masatsugu; Nishimura, Tsunehiko

    2002-01-01

    This study was designed to assess the value of gated SPECT Tc-99m-tetrofosmin (TF) wall thickening (WT) in addition to TF exercise (Ex)/rest myocardial SPECT, in comparison with F-18 fluorodeoxyglucose (FDG)-PET. The study population consisted of 33 patients with old myocardial infarction (27 men and 6 women; mean age, 62±8 years old). All patients underwent Ex/rest TF SPECT and glucose loading FDG-PET. Polar map images of Ex/rest TF were generated and divided into 24 segments for further analysis. We classified LV segments according to the exercise-rest perfusion scintigraphy. LV segments with less than 70% of the maximum TF activity on the exercise image were defined as stress-induced defects. Among these, the segments whose TF acitvity increased by 10% from exercise to rest images or exceeded 70% of the maximum uptake were defined as reversible (viable) defects. The remaining defects on the rest image were irreversible (non-viable) defect segments, and were considered for viability study on the basis of %WT. %WT was calculated according to the standard method: {(counts ES-counts ED)/ counts ED} x 100. A viable segment on gated SPECT was defined as a segment whose %WT exceeded the lower limit of the normal value (mean-SD). PET viability was defined as FDG uptake exceeding 50% of the maximum count. Among the 792 segments evaluated in the 33 patients studied, there were 689 PET viable segments. Of the 689 segments analyzed, 198 (29%) were identified as having defects on Ex images. Among these defects, 55 (8%) were reversible or partially reversible, as evidenced by rest images, and 143 (21%) were irreversible. Of the irreversible segments on Ex/rest images, 106 (15%) demonstrated no apparent WT by gated TF SPECT, whereas 37 (6%) segments with irreversible defects did have apparent WT. Overall, the sensitivity of Ex/rest TF perfusion imaging was 79%. Sensitivity was improved from 79% to 85% by combining %WT and perfusion data, but specificity was reduced from 70

  18. Development of a chest digital tomosynthesis R/F system and implementation of low-dose GPU-accelerated compressed sensing (CS) image reconstruction.

    Science.gov (United States)

    Choi, Sunghoon; Lee, Haenghwa; Lee, Donghoon; Choi, Seungyeon; Lee, Chang-Lae; Kwon, Woocheol; Shin, Jungwook; Seo, Chang-Woo; Kim, Hee-Joung

    2018-05-01

    This work describes the hardware and software developments of a prototype chest digital tomosynthesis (CDT) R/F system. The purpose of this study was to validate the developed system for its possible clinical application on low-dose chest tomosynthesis imaging. The prototype CDT R/F system was operated by carefully controlling the electromechanical subsystems through a synchronized interface. Once a command signal was delivered by the user, a tomosynthesis sweep started to acquire 81 projection views (PVs) in a limited angular range of ±20°. Among the full projection dataset of 81 images, several sets of 21 (quarter view) and 41 (half view) images with equally spaced angle steps were selected to represent a sparse view condition. GPU-accelerated and total-variation (TV) regularization strategy-based compressed sensing (CS) image reconstruction was implemented. The imaged objects were a flat-field using a copper filter to measure the noise power spectrum (NPS), a Catphan ® CTP682 quality assurance (QA) phantom to measure a task-based modulation transfer function (MTF T ask ) of three different cylinders' edge, and an anthropomorphic chest phantom with inserted lung nodules. The authors also verified the accelerated computing power over CPU programming by checking the elapsed time required for the CS method. The resultant absorbed and effective doses that were delivered to the chest phantom from two-view digital radiographic projections, helical computed tomography (CT), and the prototype CDT system were compared. The prototype CDT system was successfully operated, showing little geometric error with fast rise and fall times of R/F x-ray pulse less than 2 and 10 ms, respectively. The in-plane NPS presented essential symmetric patterns as predicted by the central slice theorem. The NPS images from 21 PVs were provided quite different pattern against 41 and 81 PVs due to aliased noise. The voxel variance values which summed all NPS intensities were inversely

  19. Free-breathing high-pitch 80kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose.

    Science.gov (United States)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Beeres, Martin; Vogl, Thomas J; Scholtz, Jan-Erik

    2017-04-01

    To investigate image quality, presence of motion artifacts and effects on radiation dose of 80kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1±4.9years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n=31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n=56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p>0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (pchest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo

    International Nuclear Information System (INIS)

    Bernard, Bert F.; Krenning, Eric P.; Breeman, Wout A. P.; Ensing, Geert; Benjamins, Harry; Bakker, Willem H.; Visser, Theo J.; Jong, Marion de

    1998-01-01

    The aim of this study was to compare uptake of 99m Tc-MIBI, 99m Tc-tetrofosmin and 99m Tc-Q12 in vitro and biodistribution in vivo in rats. In vitro, uptake decreased in the order MIBI→tetrofosmin→Q12. Uptake of MIBI and tetrofosmin, but not of Q12, in cultured tumor cells was dependent on the plasma membrane and mitochondrial potential. In vivo, heart uptake of all three compounds was high and stable. Tumor uptake decreased in the order MIBI→Q12→tetrofosmin and the tumor/blood ratio in the order MIBI→tetrofosmin→Q12

  1. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  3. Relationship between images of risk and anxiety toward radiation. Comparison of radiation from chest X-rays and nuclear power plants

    International Nuclear Information System (INIS)

    Matsui, Yuko

    2003-01-01

    In order to clarify the components of people's images of radiation risk and the determinants for the degree of anxiety about radiation exposure, an investigation was conducted. Two kinds of radiation, from nuclear power plants and during a chest X-ray, which are relatively familiar to people, were focused on. As a result, only a 'dread' factor was common to both radiation types of. Although the degree of anxiety toward both types of radiation showed a positive correlation with the 'dread' image, the anxiety toward X-ray radiation showed a negative correlation with the 'feeling of conquest'. Anxiety toward radiation from nuclear power plants had a negative correlation with 'control by experts'. These results suggest that the words radiation from nuclear power plants' evoke an image of a situation with high radiation exposure, which is beyond the experts' control abilities. (author)

  4. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    International Nuclear Information System (INIS)

    Bartosch, R.; Granegger, S.; Sinzinger, H.

    1998-01-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99m Tc-tetrofosmin and 99m Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.)

  5. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    Energy Technology Data Exchange (ETDEWEB)

    Bartosch, R.; Granegger, S.; Sinzinger, H. [Department of Nuclear Medicine, University of Vienna (Austria)

    1998-09-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.) With 4 figs., 1 tab., 7 refs.

  6. Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Bodelle, Boris, E-mail: bbodelle@googlemail.com; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Beeres, Martin; Vogl, Thomas J.; Scholtz, Jan-Erik

    2017-04-15

    Objectives: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80 kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). Materials and methods: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1 ± 4.9 years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n = 31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n = 56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Results: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p > 0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p < 0.01). Motion artifacts were reduced significantly (p = 0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p < 0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82 mGy vs. 0.92 mGy, p < 0.02; median ED: 0.4 mSv vs. 0.48 mSv, p = 0.02). Conclusions: High-pitch 80 kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation.

  7. Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose

    International Nuclear Information System (INIS)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Beeres, Martin; Vogl, Thomas J.; Scholtz, Jan-Erik

    2017-01-01

    Objectives: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80 kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). Materials and methods: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1 ± 4.9 years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n = 31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n = 56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Results: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p > 0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p < 0.01). Motion artifacts were reduced significantly (p = 0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p < 0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82 mGy vs. 0.92 mGy, p < 0.02; median ED: 0.4 mSv vs. 0.48 mSv, p = 0.02). Conclusions: High-pitch 80 kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation.

  8. Comparison of Tc-99m-tetrofosmin and Tc-99m-MIBI scintimammography in differential diagnosis of breast mass

    International Nuclear Information System (INIS)

    Park, Jung Mi; Choi, Joon Young; Lee, Kyung Han; Choi, Yong; Choe, Yearn Seong; Kim, Sang Eun; Kim, Byung Tae; Nam, Seok Jin; Yang, Jeong Hyun

    2000-01-01

    Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the differ diagnosis of breast mass. The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers independ read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. The SMM sb a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at hr. For first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIE TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MB TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr in were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% in between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 5 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the t with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not influence sensitivity and specificity between MIBI and TF SMM. The ability for the differential diag of breast tumor is

  9. Development of an imaging-planning program for screen/film and computed radiography mammography for breasts with short chest wall to nipple distance.

    Science.gov (United States)

    Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S

    2011-04-01

    Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.

  10. Trauma of the chest

    International Nuclear Information System (INIS)

    Reuter, M.

    1996-01-01

    This paper describes the typical radiologic findings in chest trauma, and the value of conventional radiography, CT, MRI, and aortography is discussed. Conventional radiography rather than cross-sectional imaging is the mainstay in diagnosing thoracic trauma. During the critical phase with often concomitant shock, pelvic and spinal injuries tailored raiographic views or even upright chest radiographs are impractical. The severely traumatized patient is usually radiographed in the supine position and suboptimal roentgenograms may have to be accepted for several reasons. It is well documented that many abnormalities detected on CT were not apparent on conventional radiographs, but CT is reserved for hemodynamical stable patients. Nevertheless certain situations like aortic rupture require further evaluation by CT and aortography. (orig./MG)

  11. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... gives detailed pictures of structures within the chest cavity, including the mediastinum , chest wall, pleura, heart and ... helpful to assess the vessels of the chest cavity (arteries and veins). MRA can also demonstrate an ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... to produce detailed pictures of organs, soft tissues, bone and virtually all other internal body structures. MRI ... of the chest. assess disorders of the chest bones (vertebrae, ribs and sternum) and chest wall soft ...

  14. Effects of tube potential and scatter rejection on image quality and effective dose in digital chest X-ray examination: An anthropomorphic phantom study

    International Nuclear Information System (INIS)

    Shaw, D.J.; Crawshaw, I.; Rimmer, S.D.

    2013-01-01

    Objectives: The purpose of this study was to investigate the effects of tube potential and scatter rejection techniques on image quality of digital posteroanterior (PA) chest radiographs. Methods: An anthropomorphic phantom was imaged using a range of tube potentials (81–125 kV p ) without scatter rejection, with an anti-scatter grid, and using a 10 cm air gap. Images were anonymised and randomised before being evaluated using a visual graded analysis (VGA) method. Results: The effects of tube potential on image quality were found to be negligible (p > 0.63) for the flat panel detector (FPD). Decreased image quality (p = 0.031) was noted for 125 kV p relative to 109 kV p , though no difference was noted for any of the other potentials (p > 0.398) for computed radiography (CR). Both scatter rejection techniques improved image quality (p p . Scatter rejection improved image quality, but with no difference found between techniques. The air-gap resulted in a smaller increase in effective dose than the anti-scatter grid and would be the preferred scatter rejection technique

  15. Chest tomosynthesis: technical and clinical perspectives.

    Science.gov (United States)

    Johnsson, Ase Allansdotter; Vikgren, Jenny; Bath, Magnus

    2014-02-01

    The recent implementation of chest tomosynthesis is built on the availability of large, dose-efficient, high-resolution flat panel detectors, which enable the acquisition of the necessary number of projection radiographs to allow reconstruction of section images of the chest within one breath hold. A chest tomosynthesis examination obtains the increased diagnostic information provided by volumetric imaging at a radiation dose comparable to that of conventional chest radiography. There is evidence that the sensitivity of chest tomosynthesis may be at least three times higher than for conventional chest radiography for detection of pulmonary nodules. The sensitivity increases with increasing nodule size and attenuation and decreases for nodules with subpleural location. Differentiation between pleural and subpleural lesions is a known pitfall due to the limited depth resolution in chest tomosynthesis. Studies on different types of pathology report increased detectability in favor of chest tomosynthesis in comparison to chest radiography. The technique provides improved diagnostic accuracy and confidence in the diagnosis of suspected pulmonary lesions on chest radiography and facilitates the exclusion of pulmonary lesions in a majority of patients, avoiding the need for computed tomography (CT). However, motion artifacts can be a cumbersome limitation and breathing during the tomosynthesis image acquisition may result in severe artifacts significantly affecting the detectability of pathology. In summary, chest tomosynthesis has been shown to be superior to chest conventional radiography for many tasks and to be able to replace CT in selected cases. In our experience chest tomosynthesis is an efficient problem solver in daily clinical work. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. The HEART score is useful to predict cardiovascular risks and reduces unnecessary cardiac imaging in low-risk patients with acute chest pain.

    Science.gov (United States)

    Dai, Siping; Huang, Bo; Zou, Yunliang; Guo, Jianbin; Liu, Ziyong; Pi, Dangyu; Qiu, Yunhong; Xiao, Chun

    2018-06-01

    The present study was to investigate whether the HEART score can be used to evaluate cardiovascular risks and reduce unnecessary cardiac imaging in China.Acute coronary syndrome patients with the thrombosis in myocardial infarction risk score risk HEART score group and 2 patients (1.5%) in the high risk HEART score group had cardiovascular events. The sensitivity of HEART score to predict cardiovascular events was 100% and the specificity was 46.7%. The potential unnecessary cardiac testing was 46.3%. Cox proportional hazards regression analysis showed that per one category increase of the HEART score was associated with nearly 1.3-fold risk of cardiovascular events.In the low-risk acute chest pain patients, the HEART score is useful to physicians in evaluating the risk of cardiovascular events within the first 30 days. In addition, the HEART score is also useful in reducing the unnecessary cardiac imaging.

  17. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and99mTc-tetrofosmin: Method and validation

    OpenAIRE

    Shrestha, U; Sciammarella, M; Alhassen, F; Yeghiazarians, Y; Ellin, J; Verdin, E; Boyle, A; Seo, Y; Botvinick, EH; Gullberg, GT

    2017-01-01

    © 2015, American Society of Nuclear Cardiology. Background: The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Methods: Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients w...

  18. Cardiothoracic ratio on chest radiograph in pediatric heart disease: How does it correlate with heart volumes at magnetic resonance imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Grotenhuis, Heynric B. [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); Zhou, Cheng; Isaac, Kathryn V. [The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Tomlinson, George [University of Toronto, Department of Medicine, Toronto General Hospital and Mt. Sinai Hospital, Toronto (Canada); Seed, Mike; Grosse-Wortmann, Lars; Yoo, Shi-Joon [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada)

    2015-10-15

    The cardiothoracic ratio by chest radiograph is widely used as a marker of cardiac size. The purpose of this study is to correlate cardiothoracic ratio and cardiac volumes as measured by cardiovascular magnetic resonance (MR) in common structural and myopathic heart disease with increased cardiac size due to volume overload or hypertrophy. A retrospective single center study was performed in all patients between 2007 and 2013 with repaired tetralogy of Fallot (TOF), aortic regurgitation, isolated left-to-right shunt and hypertrophic cardiomyopathy (HCM) who underwent cardiovascular MR and chest radiograph within 6 months of each other. Cardiothoracic ratios by chest radiograph (frontal and lateral) were compared to cardiac volumes (indexed for body surface area) by cardiovascular MR. One hundred twenty-seven patients (mean age: 11.2 ± 5.5 years) were included in this study (76 with TOF, 23 with isolated left-to-right shunt, 16 with aortic regurgitation and 12 with HCM). Frontal cardiothoracic ratio of all groups correlated with indexed right ventricular (RV) end-diastolic volume (EDVI) (r = 0.40, P < 0.01) and indexed total heart volume (THVI) (r = 0.27, P < 0.01). In TOF patients, frontal cardiothoracic ratio correlated with RVEDVI (r = 0.34, P < 0.01; coefficient of variation = 27.6%), indexed RV end-systolic volume (ESVI) (r = 0.44, P < 0.01; coefficient of variation = 33.3%) and THVI (r = 0.35, P < 0.01; coefficient of variation = 19.6%), although RV volumes and THVI showed widespread variation given the high coefficients of variation. In patients with aortic regurgitation, frontal cardiothoracic ratio correlated with left ventricular (LV) EDVI (r = 0.50, P = 0.047), but not with THVI and aortic regurgitant fraction, and widespread variation for LV EDVI (coefficient of variation = 19.2%), LV ESVI (coefficient of variation = 32.5%) and THVI (coefficient of variation = 13.6%) was also observed. Frontal cardiothoracic ratio was not correlated with cardiac volumes

  19. Identification of Pulmonary Hypertension Caused by Left-Sided Heart Disease (World Health Organization Group 2) Based on Cardiac Chamber Volumes Derived From Chest CT Imaging.

    Science.gov (United States)

    Aviram, Galit; Rozenbaum, Zach; Ziv-Baran, Tomer; Berliner, Shlomo; Topilsky, Yan; Fleischmann, Dominik; Sung, Yon K; Zamanian, Roham T; Guo, Haiwei Henry

    2017-10-01

    Evaluations of patients with pulmonary hypertension (PH) commonly include chest CT imaging. We hypothesized that cardiac chamber volumes calculated from the same CT scans can yield additional information to distinguish PH related to left-sided heart disease (World Health Organization group 2) from other PH subtypes. Patients who had PH confirmed by right heart catheterization and contrast-enhanced chest CT studies were enrolled in this retrospective multicenter study. Cardiac chamber volumes were calculated using automated segmentation software and compared between group 2 and non-group 2 patients with PH. This study included 114 patients with PH, 27 (24%) of whom were classified as group 2 based on their pulmonary capillary wedge pressure. Patients with group 2 PH exhibited significantly larger median left atrial (LA) volumes (118 mL vs 63 mL; P volumes (90 mL vs 76 mL; P = .02), and smaller median right ventricular (RV) volumes (173 mL vs 210 mL; P = .005) than did non-group 2 patients. On multivariate analysis adjusted for age, sex, and mean pulmonary arterial pressure, group 2 PH was significantly associated with larger median LA and LV volumes (P volume ratios of RA/LA, RV/LV, and RV/LA (P = .001, P = .004, and P volumes demonstrated a high discriminatory ability for group 2 PH (area under the curve, 0.92; 95% CI, 0.870-0.968). Volumetric analysis of the cardiac chambers from nongated chest CT scans, particularly with findings of an enlarged left atrium, exhibited high discriminatory ability for identifying patients with PH due to left-sided heart disease. Copyright © 2017. Published by Elsevier Inc.

  20. Chest radiography after minor chest trauma

    International Nuclear Information System (INIS)

    Rossen, B.; Laursen, N.O.; Just, S.

    1987-01-01

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma. (orig.)

  1. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  2. Detecting parathyroid adenoma using technetium-99m tetrofosmin: comparison with P-glycoprotein and multidrug resistance related protein expression--a preliminary report

    International Nuclear Information System (INIS)

    Shiau, Y.C.; Tsai, S.C.; Wang, J.J.; Ho, S.T.; Kao, A.

    2002-01-01

    The aim of this study was to investigate the relationships among technetium-99m tetrofosmin (Tc-TF) accumulation in parathyroid adenoma and the expression of P-glycoprotein (Pgp) or multidrug resistance related protein (MRP). Before operation, 33 patients with parathyroid adenomas (larger than 1.5 gm) were studied with parathyroid scintigraphy 10 minutes and 2 hours after intravenous injection of Tc-TF before operation. Immunohistochemical analyses (IHA) were performed on multiple nonconsecutive sections of operative parathyroid specimens to detect Pgp or MRP expression. According to the results of IHA, the 33 parathyroid adenomas were separated into four groups: (1) 2 adenomas with both positive Pgp and positive MRP expression, (2) 1 adenomas with positive Pgp but negative MRP expression, (3) 2 adenomas with negative Pgp but positive MRP expression, and (4) 28 adenomas with both negative Pgp and negative MRP expression. All of 28 adenomas in the group 4 could be detected by Tc-TF parathyroid imaging. All of 5 adenomas in the groups 1 to 3 could not be detected by TcTF parathyroid imaging (p < 0.05). Not only the size of parathyroid adenomas, but also significant Pgp or MRP expression limited the sensitivity of Tc-TF parathyroid imaging to localize parathyroid adenomas before operation

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... I’d like to talk with you about chest radiography also known as chest x-rays. Chest x-rays are the most ... far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot org. Thank you for your time! ...

  4. Chest Pain: First Aid

    Science.gov (United States)

    First aid Chest pain: First aid Chest pain: First aid By Mayo Clinic Staff Causes of chest pain can vary from minor problems, such as indigestion ... 26, 2018 Original article: http://www.mayoclinic.org/first-aid/first-aid-chest-pain/basics/ART-20056705 . Mayo ...

  5. Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging

    Directory of Open Access Journals (Sweden)

    Tae-Hoon Kim

    2017-03-01

    Full Text Available This study developed a device measuring the X-ray source-detector angle (SDA and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR was evaluated using the signal-to-noise (SNR, contrast-to-noise ratio (CNR, spatial resolution, distortion and entrance surface dose (ESD. According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05, whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.

  6. The chest

    International Nuclear Information System (INIS)

    Berdon, W.E.

    1985-01-01

    Radiographic interpretation of chest films of newborns in respiratory distress remains one of the most difficult aspects of pediatric radiology. Complex pulmonary and cardiac adjustments to extrauterine life are rapidly taking place. The small, fluid-filled fetal lung must rid itself of fluid and fill with air. The high vascular resistance of the fetal pulmonary bed and the open ductus arteriosus allow shunting of blood in both directions. Films taken in this period of time may show lungs that resemble those seen in congestive heart failure or fluid overload. When these findings are observed in infants who may appear dusky or even cyanotic, the result may be the diagnosis of disease in normal infants passing through a stormy transition period. To make things worse, the films are taken as portable surpine films, usually in an isolette in the intensive care unit (ICU). The phase of respiration is difficult, if not impossible, to control, and lateral films are usually not obtained. Many of the infants are on assisted ventilation either by tube or nasal prongs-nasal continuous positive airway pressure (CPAP)-and lungs can appear over-inflated or whited out, depending on the pressures used and the phase of the respiratory cycle. Prolonged crying itself can make lungs appear semiopaque; the next breath may show such a dramatic reinflation that it is hard to believe the two films are of the same infant, made only seconds apart. Is the heart large? Or is it the thymus? Are the lungs ''wet''? Is there infection? Is there pulmonary vascular engorgement? Why are these films so hard to interpret? They have no easy answers. The radiologist must realize that the neonatal intensive care personnel, armed though they may be with blood gas values, are no better at interpreting films. If anything, they read into them what they wish to see

  7. Potential of ultrasound in the pediatric chest

    Energy Technology Data Exchange (ETDEWEB)

    Trinavarat, Panruethai, E-mail: pantrinavarat@hotmail.com [Department of Radiology, Faculty of Medicine, Chulalongkorn University, Rama IV Road, Pathumwan, Bangkok 10330 (Thailand); Riccabona, Michael, E-mail: michael.riccabona@klinikum-graz.at [Department of Radiology, Division of Pediatric Radiology, University Hospital Graz (Austria)

    2014-09-15

    Ultrasound (US) of chest, even with inherent limitations of the US beam and air, has been useful in many pediatric chest conditions. It has extended its role and is now widely used by many subspecialists in medicine. This review article will cover techniques, indications, and applications of chest US in neonates, infants and children, including also different common as well as some rare and modern aspects and applications, such as pleural effusion, pneumothorax, pulmonary lesions, mediastinum, diaphragm, and chest wall. Other related imaging modalities are also briefly discussed.

  8. Time course evaluation of myocardial perfusion after reperfusion therapy by 99mTc-tetrofosmin SPECT in patients with acute myocardial infarction.

    Science.gov (United States)

    Tanaka, R; Nakamura, T

    2001-09-01

    Myocardial perfusion imaging with 99mTc-labeled agents immediately after reperfusion therapy can underestimate myocardial salvage. It is also conceivable that delayed imaging is useful for assessing the risk area. However, to our knowledge, very few studies have sequentially evaluated these image changes. We conducted 99mTc-tetrofosmin (TF) and 123I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) SPECT before and after reperfusion to treat acute myocardial infarction and quantified changes in TF myocardial accumulation and reverse redistribution. Seventeen patients with a first myocardial infarction underwent successful reperfusion. We examined SPECT images obtained at the onset (preimage), those acquired 30 min (early image) and 6 h (delayed image) after TF injection, and images acquired 1, 4, 7, and 20 d after reperfusion (post-1-d, post-4-d, post-7-d, and post-20-d image, respectively). We also examined BMIPP SPECT images after 7 +/- 1.8 d (BMIPP image). Polar maps were divided into 48 segments to calculate percentage uptake, and time course changes in segment numbers below 60% were observed as abnormal area. Moreover, cardiac function was analyzed by gated TF SPECT on 1 and 20 d after reperfusion. In reference to the abnormal area on the early images, the post-1-d image was significantly improved compared with the preimage (P < 0.01) as was the post-7-d image compared with the post-1-d and post-4-d images (P < 0.05, respectively). However, post-20-d and post-7-d images did not significantly differ. Therefore, the improvement in myocardial accumulation reached a plateau 7 d after reperfusion. On the other hand, the abnormal area on the delayed images was significantly greater (P < 0.01) compared with that on the early images from 4 to 20 d after reperfusion, as the value was essentially constant. The correlations of the abnormal area between the preimage and the post-7-d delayed image, the preimage and the BMIPP image, and the post-7-d delayed image and the

  9. Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Mieville, Frederic A.; Bochud, Francois O.; Verdun, Francis R. [Lausanne University Hospital, Institute of Radiation Physics, Lausanne (Switzerland); Berteloot, Laureline; Brunelle, Francis [Necker Children' s Hospital of Paris and University of Paris Descartes, Department of Pediatric Radiology, Paris (France); Grandjean, Albane; Ayestaran, Paul [General Electric Medical Systems Europe, Paris (France); Gudinchet, Francois; Schmidt, Sabine [Lausanne University Hospital, Department of Radiology, Lausanne (Switzerland)

    2013-03-15

    The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO trademark is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. To evaluate the potential of VEO trademark on diagnostic image quality and dose reduction in pediatric chest CT examinations. Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDI{sub vol} 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection. (orig.)

  10. Comparison of the accumulation and efflux kinetics of technetium-99m sestamibi and technetium-99m tetrofosmin in an MRP-expressing tumour cell line

    International Nuclear Information System (INIS)

    Utsunomiya, K.; Su, Z.-F.; Ichise, M.; Ballinger, J.R.; Piquette-Miller, M.; Tang, W.; Rauth, A.M.

    2000-01-01

    The potential clinical use of technetium-99m labeled sestamibi (Tc-MIBI) and tetrofosmin (Tc-Tfos) to image tumours is currently being evaluated. In this study, the accumulation and efflux of Tc-MIBI and Tc-Tfos in the nasopharyngeal carcinoma cell line CNE-1 were examined in the presence or absence of various inhibitors of P-glycoprotein (PGP) and/or multidrug resistance associated protein (MRP) activity [GG918, PSC833, verapamil (Vrp), cyclosporin A (CsA) and buthionine sulfoximine (BSO)]. Reverse-transcriptase polymerase chain reaction analysis and immunodetection of the CNE-1 cells detected expression of MRP, MRP1 and MRP2 but not PGP. Tc-MIBI and Tc-Tfos accumulation was increased (P 2 times greater than for Tc-MIBI). However, no qualitative differences in inhibitors were seen between Tc-MIBI and Tc-Tfos. These results suggest that both Tc-MIBI and Tc-Tfos are substrates for the MRP transporter and that PSC833, Vrp, CsA and BSO but not GG918 can inhibit MRP activity. These results indicate that Tc-MIBI and Tc-Tfos may be suitable imaging agents for detecting MRP-mediated drug resistance in human cancers. (orig.)

  11. Enhanced washout of {sup 99m}Tc-tetrofosmin in hypertrophic cardiomyopathy: quantitative comparisons with regional {sup 123}I-BMIPP uptake and wall thickness determined by MRI

    Energy Technology Data Exchange (ETDEWEB)

    Thet-Thet-Lwin, Tohoru; Takeda, Jin; Wu, Yuko; Fumikura, Keiji; Iida, Satoru; Kawano, Iwao; Yamaguchi, Yuji; Itai [Institute of Clinical Medicine, University of Tsukuba, Tennodai 1-1-1, 305-8575, Tsukuba-shi, Ibaraki-ken (Japan)

    2003-07-01

    The diagnostic value of technetium-99m tetrofosmin (TF) washout in hypertrophic cardiomyopathy (HCM) was examined by investigating its relation to the metabolic abnormality depicted by iodine-123 {beta}-methyl-p-iodophenylpentadecanoic acid (BMIPP) uptake and the left ventricular (LV) myocardial wall thickness as measured by magnetic resonance imaging (MRI). TF washout was evaluated in 31 patients with HCM and 23 normal control subjects using 30-min (early) and 3-h (delayed) TF single-photon emission tomography images. The LV myocardial wall was divided into 19 segments and the percentage TF washout, regional BMIPP uptake and LV wall thickness were measured in each segment. Mean TF washout in the patients with HCM was significantly faster than that in normal control subjects (23.7{+-}5.7 vs 13.4{+-}4.1, P<0.0001). In the patients with HCM, TF washout showed an excellent correlation with MRI wall thickness (r=0.82, P<0.0001) and a good inverse correlation with regional BMIPP uptake (r=-0.72, P<0.0001). In addition, a good linear correlation was observed between TF uptake and MRI wall thickness in the 19 regional segments. In conclusion, the degree of TF washout corresponds well with the severity of myocardial wall thickness and the degree of metabolic abnormality in patients with HCM. These results suggest that enhanced TF washout might provide additional clinical information regarding metabolic alterations in HCM. (orig.)

  12. The evaluation of usefulness of quantitative analysis method with {sup 99m}Tc-tetrofosmin on effective dicision of reperfusion therapy to acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Hitoshi; Sone, Takahito [Ogaki Municipal Hospital, Gifu (Japan)

    1998-01-01

    SPECT on acute and chronic period of {sup 99m}Tc-tetrofosmin on 46 patients with acute myocardial infarction were analyzed to evaluate about usefulness of quantitative analysis method used by unfolding image that was gotten by Bull`s eye analysis on reperfusion therapy in acute myocardial infarction, and we could get undermentioned results. 60% black out area in resional of interested was best on the obstacle myocardium using analysis of unfolding image. Significantly betterment from acute to chronic phase on the obstacle area of myocardium and the mean uptake ratio of the obstacle area was confirmed by this method. The relation between myocardial salvage and factors of myocardial damage, for example reperfusion time TIMI grade, rentrop grade and reperfusion phenomenon could be analyzed by this method. This method was suspected to underestimate the areas of obstacle myocardium on the cases of defect of apex. Error of analysis was suspected on the case of accumulation of TF to other than myocardium. The problems were minimised by some techniques mention in this paper. (author)

  13. Enhanced washout of 99mTc-tetrofosmin in hypertrophic cardiomyopathy: quantitative comparisons with regional 123I-BMIPP uptake and wall thickness determined by MRI

    International Nuclear Information System (INIS)

    Thet-Thet-Lwin, Tohoru; Takeda, Jin; Wu, Yuko; Fumikura, Keiji; Iida, Satoru; Kawano, Iwao; Yamaguchi, Yuji; Itai

    2003-01-01

    The diagnostic value of technetium-99m tetrofosmin (TF) washout in hypertrophic cardiomyopathy (HCM) was examined by investigating its relation to the metabolic abnormality depicted by iodine-123 β-methyl-p-iodophenylpentadecanoic acid (BMIPP) uptake and the left ventricular (LV) myocardial wall thickness as measured by magnetic resonance imaging (MRI). TF washout was evaluated in 31 patients with HCM and 23 normal control subjects using 30-min (early) and 3-h (delayed) TF single-photon emission tomography images. The LV myocardial wall was divided into 19 segments and the percentage TF washout, regional BMIPP uptake and LV wall thickness were measured in each segment. Mean TF washout in the patients with HCM was significantly faster than that in normal control subjects (23.7±5.7 vs 13.4±4.1, P<0.0001). In the patients with HCM, TF washout showed an excellent correlation with MRI wall thickness (r=0.82, P<0.0001) and a good inverse correlation with regional BMIPP uptake (r=-0.72, P<0.0001). In addition, a good linear correlation was observed between TF uptake and MRI wall thickness in the 19 regional segments. In conclusion, the degree of TF washout corresponds well with the severity of myocardial wall thickness and the degree of metabolic abnormality in patients with HCM. These results suggest that enhanced TF washout might provide additional clinical information regarding metabolic alterations in HCM. (orig.)

  14. Enhanced washout of 99mTc-tetrofosmin in hypertrophic cardiomyopathy: quantitative comparisons with regional 123I-BMIPP uptake and wall thickness determined by MRI.

    Science.gov (United States)

    Thet-Thet-Lwin; Takeda, Tohoru; Wu, Jin; Fumikura, Yuko; Iida, Keiji; Kawano, Satoru; Yamaguchi, Iwao; Itai, Yuji

    2003-07-01

    The diagnostic value of technetium-99m tetrofosmin (TF) washout in hypertrophic cardiomyopathy (HCM) was examined by investigating its relation to the metabolic abnormality depicted by iodine-123 beta-methyl- p-iodophenylpentadecanoic acid (BMIPP) uptake and the left ventricular (LV) myocardial wall thickness as measured by magnetic resonance imaging (MRI). TF washout was evaluated in 31 patients with HCM and 23 normal control subjects using 30-min (early) and 3-h (delayed) TF single-photon emission tomography images. The LV myocardial wall was divided into 19 segments and the percentage TF washout, regional BMIPP uptake and LV wall thickness were measured in each segment. Mean TF washout in the patients with HCM was significantly faster than that in normal control subjects (23.7+/-5.7 vs 13.4+/-4.1, P<0.0001). In the patients with HCM, TF washout showed an excellent correlation with MRI wall thickness ( r=0.82, P<0.0001) and a good inverse correlation with regional BMIPP uptake ( r=-0.72, P<0.0001). In addition, a good linear correlation was observed between TF uptake and MRI wall thickness in the 19 regional segments. In conclusion, the degree of TF washout corresponds well with the severity of myocardial wall thickness and the degree of metabolic abnormality in patients with HCM. These results suggest that enhanced TF washout might provide additional clinical information regarding metabolic alterations in HCM.

  15. Quantitative evaluation of interstitial pneumonia using 3D-curved high-resolution CT imaging parallel to the chest wall: A pilot study.

    Directory of Open Access Journals (Sweden)

    Hiroyasu Umakoshi

    Full Text Available To quantify the imaging findings of patients with interstitial pneumonia (IP and emphysema using three-dimensional curved high-resolution computed tomography (3D-cHRCT at a constant depth from the chest wall, and compare the results to visual assessment of IP and each patient's diffusing capacity of the lungs for carbon monoxide (DLco.We retrospectively reviewed the axial CT findings and pulmonary function test results of 95 patients with lung cancer (72 men and 23 women, aged 45-84 years with or without IP, as follows: non-IP (n = 47, mild IP (n = 31, and moderate IP (n = 17. The 3D-cHRCT images of the lung at a 1-cm depth from the chest wall were reconstructed automatically using original software; total area (TA, high-attenuation area (HAA >-500 HU, and low-attenuation area (LAA <-950 HU were calculated on a workstation. The %HAA and %LAA were calculated as follows: [Formula: see text], and [Formula: see text].The %HAA and %LAA respective values were 3.2±0.9 and 27.7±8.2, 3.9±1.2 and 27.6±5.9, and 6.9±2.2 and 25.4±8.7 in non-IP, mild IP, and moderate IP patients, respectively. There were significant differences in %HAA between the 3 groups of patients (P<0.001, but no differences in %LAA (P = 0.558. Multiple linear regression analysis revealed that %HAA and %LAA were negatively correlated with predicted DLco (standard partial regression coefficient [b*] = -0.453, P<0.001; b* = -0.447, P<0.001, respectively.The %HAA and %LAA values computed using 3D-cHRCT were significantly correlated with DLco and may be important quantitative parameters for both IP and emphysema.

  16. Scatter and cross-talk correction for one-day acquisition of 123I-BMIPP and 99mtc-tetrofosmin myocardial SPECT.

    Science.gov (United States)

    Kaneta, Tomohiro; Kurihara, Hideyuki; Hakamatsuka, Takashi; Ito, Hiroshi; Maruoka, Shin; Fukuda, Hiroshi; Takahashi, Shoki; Yamada, Shogo

    2004-12-01

    123I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99mTc-tetrofosmin (TET) are widely used for evaluation of myocardial fatty acid metabolism and perfusion, respectively. ECG-gated TET SPECT is also used for evaluation of myocardial wall motion. These tests are often performed on the same day to minimize both the time required and inconvenience to patients and medical staff. However, as 123I and 99mTc have similar emission energies (159 keV and 140 keV, respectively), it is necessary to consider not only scattered photons, but also primary photons of each radionuclide detected in the wrong window (cross-talk). In this study, we developed and evaluated the effectiveness of a new scatter and cross-talk correction imaging protocol. Fourteen patients with ischemic heart disease or heart failure (8 men and 6 women with a mean age of 69.4 yr, ranging from 45 to 94 yr) were enrolled in this study. In the routine one-day acquisition protocol, BMIPP SPECT was performed in the morning, with TET SPECT performed 4 h later. An additional SPECT was performed just before injection of TET with the energy window for 99mTc. These data correspond to the scatter and cross-talk factor of the next TET SPECT. The correction was performed by subtraction of the scatter and cross-talk factor from TET SPECT. Data are presented as means +/- S.E. Statistical analyses were performed using Wilcoxon's matched-pairs signed-ranks test, and p corrected total count was 26.0 +/- 5.3%. EDV and ESV after correction were significantly greater than those before correction (p = 0.019 and 0.016, respectively). After correction, EF was smaller than that before correction, but the difference was not significant. Perfusion scores (17 segments per heart) were significantly lower after as compared with those before correction (p correction revealed significant differences in EDV, ESV, and perfusion scores. These observations indicate that scatter and cross-talk correction is required for one

  17. Testing the radiochemical purity of a radiopharmaceutical: study of {sup 99m}Tc-Tetrofosmin (Myoview); Controle de la purete radiochimique d`un radiopharmaceutique: etude du {sup 99m}Tc-Tetrofosmin (Myoview)

    Energy Technology Data Exchange (ETDEWEB)

    Moati, F.; Quartarone, C.; Jourdain, J.R.; Rizzo, N.; Dumont, A.; De Beco, V.; Ait Ben Ali, S.; Lours, S.; Piketty, M.L.; Izembart, M.; Goudou, C.; Lemercier, V.; Schlageter, M.H.; Moretti, J.L.; Progent, A. [Groupe de travail `Radiopharmaceutiques - Ile de France` (France)

    1997-12-31

    The goal of this study is to optimize the testing method of radiochemical purity (RCP) of {sup 99m}Tc-Tetrofosmin proposed by the Amersham Company: thin-layer chromatography (TLC); ITLC-SG support, migration on 15 Cm; acetone-dichloromethane mobile phase, (35/65, v/v), This technique allows separating the reduced-Tc (Rf = 0), the TcO{sub 4}{sup -} (Rf = 1), and in intermediary position (0.2Tetrofosmin. The results of RCP depend on working conditions, particularly, on the volume of deposit (10 to 20 {mu}l, expected). If the deposited is too small, the {sup 99m}Tc-Tetrofosmin does not migrate. With a volume of 20 {mu}l, the separation is weak and the peak width is un-resolvable. The results obtained correspond to the following operational conditions: migration on 8 cm; deposit of 8 to 10 {mu}l; no drying. In these conditions the peak of {sup 99m}Tc-Tetrofosmin is well singled out: migration Rf of 0.375 to 0.625. These results have been obtained by the analysis of radio-chromatographic peak. Every strip has been cut cm by cm and the activity was measured by a gamma counter. Repeatability of the method on a series of 8 tests is good: average RCP 93.22%, mean value = 93.24%. The reproducibility was realized by measuring directly by the activity-meter the activity corresponding to 3 identifiable peaks: Reduced Tc (Rf < 0.25), TcO{sub 4}{sup -} (Rf < 0.75), and {sup 99m}Tc-Tetrofosmin (0.25 < Rf < 0.75). On the 21 effectuated tests the inter-test RCP reproducibility was good: average value = 95.24%, CV = 2.07%, mean value 95.3%. In conclusion, the miniaturization improves the separation by Myoview (0.25 < Rf < 0.75), diminishes the migration time by a factor 4 and lowers the reactive cost of testing by 50%

  18. Chest CT in children: anesthesia and atelectasis

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley; Gawande, Rakhee [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States); Krane, Elliot J. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford, CA (United States); Holmes, Tyson H. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Psychiatry and Behavioral Sciences, Stanford, CA (United States); Robinson, Terry E. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Pulmonary Medicine and Cystic Fibrosis Center for Excellence in Pulmonary Biology, Stanford, CA (United States)

    2014-02-15

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  19. Chest CT in children: anesthesia and atelectasis

    International Nuclear Information System (INIS)

    Newman, Beverley; Gawande, Rakhee; Krane, Elliot J.; Holmes, Tyson H.; Robinson, Terry E.

    2014-01-01

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  20. Diagnostic Yield of Recommendations for Chest CT Examination Prompted by Outpatient Chest Radiographic Findings

    Science.gov (United States)

    Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.

    2015-01-01

    Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in 20.6% (142 of 691 [95% CI: 17.6%, 23.8%]) of cases, and no corresponding abnormalities in 38

  1. Radiological diagnostic in acute chest pain

    International Nuclear Information System (INIS)

    Kawel, Nadine; Bremerich, Jens

    2010-01-01

    Acute chest pain is one of the main symptoms leading to a consultation of the emergency department. Main task of the initial diagnostic is the confirmation or exclusion of a potentially life threatening cause. Conventional chest X-ray and computed tomography are the most significant techniques. Due to limited availability and long examination times magnetic resonance tomography rather plays a limited role in routine clinical workup. In the following paper we will systematically review the radiological diagnostic of the acute life threatening causes of chest pain. Imaging modalities, technical aspects and image interpretation will be discussed. (orig.)

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... and chest wall and may be used to help evaluate shortness of breath, persistent cough, fever, chest ... or injury. It may also be useful to help diagnose and monitor treatment for a variety of ...

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... to assess the anatomy and function of the heart and its blood flow. Tell your doctor about ... chest cavity, including the mediastinum , chest wall, pleura, heart and vessels, from almost any angle. MRI also ...

  6. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  7. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  8. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and

  9. Heartburn or Chest Pain: When Is It Heart Attack?

    Science.gov (United States)

    ... of cardiovascular imaging in emergency department patients with chest pain: A joint document of the American College of Radiology Appropriateness Criteria Committee and the American College of ...

  10. Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients

    International Nuclear Information System (INIS)

    D'Agostino, A.G.; Remy-Jardin, M.; Khalil, C.; Remy, J.; Delannoy-Deken, V.; Duhamel, A.; Flohr, T.

    2006-01-01

    The purpose of this study was to evaluate image quality of low-dose electrocardiogram (ECG)-gated multislice helical computed tomography (CT) angiograms of the chest. One hundred and five consecutive patients with a regular sinus rhythm (72 men; 33 women) underwent ECG-gated CT angiographic examination of the chest without administration of beta blockers using the following parameters: (a) collimation 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices, rotation time 0.33 s, pitch 0.3; (b) 120 kV, 200 mAs; (c) use of two dose modulation systems, including adjustment of the mAs setting to the patient's size and anatomical shape and an ECG-controlled tube current. Subjective and objective image quality was evaluated by two radiologists in consensus on 3-mm-thick scans reconstructed at 55% of the response rate (RR) interval. The population and protocol characteristics included: (a) a mean [±standard deviation (SD)] body mass index (BMI) of 24.47 (±4.64); (b) a mean (±SD) heart rate of 72.04 (±15.76) bpm; (c) a mean (±SD) scanning time of 18.3 (±2.73) s; (d) a mean (±SD) dose-length product (DLP) value of 260.57 (±83.67) mGy/cm; (e) an estimated average effective dose of 4.95 (±1.59) mSv. Subjective noise was depicted in a total of nine examinations (8.5%), always rated as mild. Objective noise was assessed by measuring the standard deviation of pixel values in a homogeneous region of interest within the trachea and descending aorta; SD was 15.91 HU in the trachea and 22.16 HU in the descending aorta, with no significant difference in the mean value of the standard deviations between the four categories of BMI except for obese patients, who had a higher mean SD within the aorta. Interpolation artefacts were depicted in 22 patients, with a mean heart rate significantly lower than that of patients without interpolation artifacts, rated as mild in 11 patients and severe in 11 patients. The severity of interpolation artefacts

  11. Effects of display resolution and size on primary diagnosis of chest images using a high-resolution electronic work station

    International Nuclear Information System (INIS)

    Fuhrman, C.R.; Cooperstein, L.A.; Herron, J.; Good, W.F.; Good, B.; Gur, D.; Maitz, G.; Tabor, E.; Hoy, R.J.

    1987-01-01

    To evaluate the acceptability of electronically displayed planar images, the authors have a high-resolution work station. This system utilizes a high-resolution film digitizer (100-micro resolution) interfaced to a mainframe computer and two high-resolution (2,048 X 2,048) display devices (Azuray). In a clinically simulated multiobserver blind study (19 cases and five observers) a prodetermined series of reading sessions is stored on magnetic disk and is transferred to the displays while the preceding set of images is being reviewed. Images can be linearly processed on the fly into 2,000 X 2,000 full resolution, 1,000 X 1,000 minified display, or 1,000 X 1,000 interpolated for full-size display. Results of the study indicate that radiologists accept but do not like significant minification (more than X2), and they rate 2,000 X 2,000 images as having better diagnostic quality than 1,000 X 1,000 images

  12. Lung region extraction based on the model information and the inversed MIP method by using chest CT images

    International Nuclear Information System (INIS)

    Tomita, Toshihiro; Miguchi, Ryosuke; Okumura, Toshiaki; Yamamoto, Shinji; Matsumoto, Mitsuomi; Tateno, Yukio; Iinuma, Takeshi; Matsumoto, Toru.

    1997-01-01

    We developed a lung region extraction method based on the model information and the inversed MIP method in the Lung Cancer Screening CT (LSCT). Original model is composed of typical 3-D lung contour lines, a body axis, an apical point, and a convex hull. First, the body axis. the apical point, and the convex hull are automatically extracted from the input image Next, the model is properly transformed to fit to those of input image by the affine transformation. Using the same affine transformation coefficients, typical lung contour lines are also transferred, which correspond to rough contour lines of input image. Experimental results applied for 68 samples showed this method quite promising. (author)

  13. American College of Chest Physicians

    Science.gov (United States)

    ... Foundation Participate in the e-Community Get Social Career Connection Publications CHEST Journal CHEST SEEK Guidelines & Consensus Statements CHEST Physician CHEST NewsBrief Coding for Chest Medicine Tobacco Dependence Toolkit (3rd Ed.) Mobile Websites and Apps CHEST Journal ...

  14. Improved detection of fill-in using sublingual nitroglycerin in technetium-99m tetrofosmin exercise/rest single photon emission computed tomography one day protocol for old myocardial infarction

    International Nuclear Information System (INIS)

    Miyanaga, Hajime; Kunieda, Yasufumi; Oguni, Atsuhiko; Kamitani, Tadaaki; Kawasaki, Shingo; Takahashi, Toru

    1999-01-01

    Twenty-one patients with old myocardial infarction underwent repeated 99m Tc-tetrofosmin ( 99m Tc) exercise/rest same day protocols with and without the administration of sublingual nitroglycerin (NTG) 5 min before the second injection of 99m Tc for rest SPECT. Twelve of these patients also underwent ordinary exercise/redistribution 201 Tl SPECT. The control study protocol images showed decreased uptake of 99m Tc on exercise in 157 of 420 segments and the presence of fill-in at rest in 58 segments. Images obtained with administration of NTG showed decreased uptake of 99m Tc on exercise in 163 of 420 segments and fill-in in 74 segments at rest. The frequency of fill-in was greater in the NTG protocol than in the control protocol. The segments were scored as different grades according to 99m Tc uptake between 2 protocols. Fill-in was only present or more remarkable in 31 segments in the NTG protocol than in the control protocol. Fill-in was only present or more remarkable in 10 segments in the control protocol than in the NTG protocol. In the NTG protocol, the mean defect score of the exercise images, calculated from the bull's eye image automatically, was higher than that of the rest images. The mean severity score of the exercise images, also calculated from the bull's eye image automatically, was likewise higher than that of the rest images, whereas the mean severity score of the stress images and rest images in the control protocol was not significantly different. Moreover, the mean defect score and severity score of the rest images from the NTG protocol were significantly lower than those obtained from the control protocol. Sublingual NTG administration before the injection of 99m Tc-tetrofosmin at the rest study in the one day exercise/rest studies enhanced fill-in, so may enhance the detection of viable myocardium, allowing more informed decisions regarding cardiac revascularization in patients with chronic coronary artery disease. (K.H.)

  15. A history of a prior myocardial infarct does not negate the utility of myocardial perfusion imaging in the evaluation of acute chest pain syndromes

    International Nuclear Information System (INIS)

    Zhou Danbing; Jonathan Knott; Leeanne Grigg; Meir Lichtenstein; Nathan Better

    2004-01-01

    Purpose: Acute myocardial perfusion imaging (MPI) for evaluation of patients with acute chest pain and a non-diagnostic electrocardiogram (ECG) has a high sensitivity and moderate specificity to detect acute ischaemia and predict cardiac events. However, previous studies excluded patients with a history of prior myocardial infarction (MI). The purpose of our study was to assess the utility of acute MPI for evaluating patients with acute chest pain and a non-diagnostic ECG. We aim to study patients both with and without a history of prior MI, including normal and abnormal studies, as well as to assess the independent predictive value of a prior MI history in determining patient outcome. Methods: We studied 367 consecutive patients with (group 1, n--107) and without. (group 2, n=260) a history of prior MI. 800 MBq Tc99m sestamibi was injected while chest pain was present ('HOT' MIBI). SPECT imaging was performed 1-6 hours post injection. Scan results were reported as,normal, ischaemia, infarct or equivocal. For patients with a defect, a 24-hour painfree study ( C OLD' MIBI) was offered to differentiate ischaemia from infarct. Follow-up was at 1 year by review of the patient's medical record. Outcomes were (1) Hard cardiac events (HE), defined as cardiac death and non-fatal MI, and (2) Total cardiac events (TE), defined as HE or revascularisation. Results: For the total study population, 206 had a normal study, with a HE rate 0.97% (2/206), while 161 had an abnormal study, with HE rate 12.4% (20/161). Patients in Group 2 were much more likely to have a normal study than those in Group 1 (p<.001). An equivocal result is seen in 5 patients, with no cardiac events, while 5 patients had a non-cardiac death. These groups were too small for separate analysis. A COLD MIBI was required in 77.6% of group 1, but only 24.2% of group 2 patients (p<0.001). On univariate analysis, acute ischaemia on MIBI scan, history of prior MI, diabetes, Q wave on ECG and age are all predictors

  16. Upgrade to iterative image reconstruction (IR) in MDCT imaging: a clinical study for detailed parameter optimization beyond vendor recommendations using the adaptive statistical iterative reconstruction environment (ASIR) Part2: The chest.

    Science.gov (United States)

    Mueck, F G; Michael, L; Deak, Z; Scherr, M K; Maxien, D; Geyer, L L; Reiser, M; Wirth, S

    2013-07-01

    To compare the image quality in dose-reduced 64-row CT of the chest at different levels of adaptive statistical iterative reconstruction (ASIR) to full-dose baseline examinations reconstructed solely with filtered back projection (FBP) in a realistic upgrade scenario. A waiver of consent was granted by the institutional review board (IRB). The noise index (NI) relates to the standard deviation of Hounsfield units in a water phantom. Baseline exams of the chest (NI = 29; LightSpeed VCT XT, GE Healthcare) were intra-individually compared to follow-up studies on a CT with ASIR after system upgrade (NI = 45; Discovery HD750, GE Healthcare), n = 46. Images were calculated in slice and volume mode with ASIR levels of 0 - 100 % in the standard and lung kernel. Three radiologists independently compared the image quality to the corresponding full-dose baseline examinations (-2: diagnostically inferior, -1: inferior, 0: equal, + 1: superior, + 2: diagnostically superior). Statistical analysis used Wilcoxon's test, Mann-Whitney U test and the intraclass correlation coefficient (ICC). The mean CTDIvol decreased by 53 % from the FBP baseline to 8.0 ± 2.3 mGy for ASIR follow-ups; p ASIR 70 % in volume mode (-0.07 ± 0.29, p = 0.29). Concerning the lung kernel, every ASIR level outperformed the baseline image quality (p ASIR 30 % rated best (slice: 0.70 ± 0.6, volume: 0.74 ± 0.61). Vendors' recommendation of 50 % ASIR is fair. In detail, the ASIR 70 % in volume mode for the standard kernel and ASIR 30 % for the lung kernel performed best, allowing for a dose reduction of approximately 50 %. © Georg Thieme Verlag KG Stuttgart · New York.

  17. The Image Quality of a Digital Chest X-Ray Radiography System: Comparison of Quantitative Image Quality Analysis and Radiologists' Visual Scoring

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ji Ho [Dept. of Radiology Oncology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of); Chung, Myung Jin [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Park, Darl; Kim, Won Taek; Kim, Yong Ho; Ki, Yong Kan; Kim, DFong Hyun; Lee, Ju Hee; Kim, Dong Won [Dept. of Radiology Oncology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of); Jeon, Ho Sang [Reserach Institue for Convergence of Biomedical Science and Technology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of)

    2011-11-15

    To evaluate the performance of imaging devices, which should be periodically monitored to maintain high quality images to the radiologists. Additionally, this evaluation may prevent patients from radiation over-exposure. The most suitable engineering standard for imaging performance evaluation of digital X-ray thoracic images was determined. IEC 62220-1 standards were used to evaluate the performance of the images. In succession, the visibilities of overall image, pneumothorax, and humerus head in anthropomorphic thoracic phantom images were used to evaluate the image qualities by radiologists. The rank correlation coefficient (p) of visual scoring by radiologists with system spatial resolution is not meaningful (p-value, p = 0.295), but is significant with image noise (p-value, p -0.9267). Finally, the noise equivalent quanta (NEQ) presents a high rank correlation for visual scoring of radiologists (p-value, p = 0.9320). Image quality evaluation of radiologists were mainly affected by imaging noise. Hence, the engineered standard for evaluating image noise is the most important index to effectively monitor the performance of X-ray images. Additionally, the NEQ can be used to evaluate the performance of radiographic systems, because it theoretically corresponds to the synthetic image quality of systems.

  18. Assessment of ischemic heart disease by dipyridamole stress electrocardiographic gated myocardial single photon emission computed tomography with technetium-99m tetrofosmin

    International Nuclear Information System (INIS)

    Kanna, Masahiko; Mitani, Isao; Nakamaru, Masashi; Shibuya, Ken; Takeda, Kazuyoshi; Asahina, Shigeru; Kitamura, Yutaka; Higuma, Kikuhiko; Ishii, Masao

    1998-01-01

    Simultaneous assessment of stress perfusion and rest function is possible with gated single photon emission computed tomography (SPECT) using stress injected technetium-99m ( 99m Tc) tetrofosmin (TF). The feasibility of dipyridamole stress electrocardiographic gated myocardial SPECT (GSPECT) with TF was examined as an alternative to conventional stress/rest imaging. Fifty-one patients underwent stress GSPECT. 740 MBq of TF was administered 3 min after dipyridamole infusion. GSPECT acquisition was performed one hour after the injection. Additional rest SPECT was performed on another day only in patients with abnormal perfusion on stress images. Perfusion and thickening were analyzed visually on 17 segments of the left ventricle. Percentage of wall thickening (%WT) was also calculated in 17 segments of the polar map. Thirty-two of 51 patients (63%) had normal stress perfusion and normal rest thickening. Nineteen of 51 patients (37%) had abnormal perfusion on stress images. Among 157 abnormal perfusion segments of the 19 patients, 139 segments (89%) had thickening and the rest (11%) had no thickening. %WT was higher in the reversible segments with or without thickening. There was better agreement for the identification of normal segments and the presence of reversibility between stress GSPECT and the conventional stress/rest study in patients without previous myocardial infarction than in those with previous myocardial infarction (89% vs 79%). These results suggest that stress GSPECT may substitute for conventional stress/rest perfusion study in patients without previous myocardial infarction, allowing shorter examination time and lower cost. However, stress GSPECT does not replace the need for rest perfusion study in patients with previous myocardial infarction, because of underestimation of viability, but %WT may eliminate this underestimation. (author)

  19. Computer-aided diagnosis workstation and data base system for chest diagnosis based on multihelical CT images

    International Nuclear Information System (INIS)

    Satoh, H.; Niki, N.; Eguchi, K.; Masuda, H.; Machida, S.; Moriyama, N.

    2006-01-01

    We have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router, Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information. (author)

  20. Improving screen-film chest radiography

    International Nuclear Information System (INIS)

    Shaikh, N.; Baker, R.A.

    1996-01-01

    Traditionally symmetric screens and double emulsion symmetric films with medium to wide latitutde are used for radiography of the chest. Beacuse of mismatch of transmitted exposure through the chest with limited latitude of the film, most of the dense areas of the chest are underexposed. Kodak's recent innovation of a unique asymmetry screen-film system (InSight) alleviates this problem. Our phantom measurement indicates that the InSight system offers wider recording range, and the flexible grid permits more positional latitude than conventional grids. Our five-year extensive clinical experience indicates that dense anatomic structures, such as mediastinum, retrocardiac and subdiaphragmatic, are more visible in the InSight system than in the conventional symmetric system. Similarly, a substantial improvement in image quality in portable chest imaging is realized by use of flexible grids because of scatter rejection and invisible grid lines. (author)

  1. Pulmonary effects of synthetic marijuana: chest radiography and CT findings.

    Science.gov (United States)

    Berkowitz, Eugene A; Henry, Travis S; Veeraraghavan, Srihari; Staton, Gerald W; Gal, Anthony A

    2015-04-01

    The purpose of this article is to present the first chest radiographic and CT descriptions of organizing pneumonia in response to smoking synthetic marijuana. Chest radiographs showed a diffuse miliary-micronodular pattern. Chest CT images showed diffuse centrilobular nodules and tree-in-bud pattern and a histopathologic pattern of organizing pneumonia with or without patchy acute alveolar damage. This distinct imaging pattern should alert radiologists to include synthetic marijuana abuse in the differential diagnosis.

  2. Blunt chest trauma.

    Science.gov (United States)

    Stewart, Daphne J

    2014-01-01

    Blunt chest trauma is associated with a wide range of injuries, many of which are life threatening. This article is a case study demonstrating a variety of traumatic chest injuries, including pathophysiology, diagnosis, and treatment. Literature on the diagnosis and treatment was reviewed, including both theoretical and research literature, from a variety of disciplines. The role of the advance practice nurse in trauma is also discussed as it relates to assessment, diagnosis, and treatment of patients with traumatic chest injuries.

  3. CT of chest trauma

    International Nuclear Information System (INIS)

    Goodman, P.C.

    1986-01-01

    There appears to be a limited role for computed tomography in the evaluation of chest trauma. The literature contains few papers specifically addressing the use of CT in the setting of chest trauma. Another series of articles relates anecdotal experiences in this regard. This paucity of reports attests to the remarkable amount of information present on conventional chest radiographs as well as the lack of clear indications for CT in the setting of chest trauma. In this chapter traumatic lesions of various areas of the thorax are discussed. The conventional radiographic findings are briefly described and the potential or proven application of CT is addressed

  4. Dobutamine stress tetrofosmin SPECT. Evaluation of short rest-stress protocol and head to head comparison with MIBI in detection of coronary artery disease

    International Nuclear Information System (INIS)

    Turgut, B.; Unlu, M.; Cengel, A.

    2005-01-01

    The purpose of the present study was to evaluate the feasibility and diagnostic accuracy of same day short rest-dobutamine stress Tetrofosmin (TF) SPECT imaging protocol and to compare TF SPECT results with methoxyisobutyl isonitrile (MIBI) SPECT in the same subjects who were unable to perform treadmill exercise or were unsuitable for pharmacological vasodilator stress. The study group consisted of 19 patients (2 female and 17 male, with a mean age of 53.8±7.9 yrs) in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography (CA). MIBI SPECT imaging was performed first. TF SPECT images were obtained one week after MIBI imaging. Immediately after the rest SPECT imaging in both of the MIBI and TF studies, patients underwent dobutamine stress tests. Rest-stress radiotracer doses and dobutamine doses were the same for both TF and MIBI studies. While 60 min waiting periods were applied for MIBI study, only 30 min waiting periods were applied for TF study after the rest and stress injections. Images were evaluated by visual and quantitative analysis. Dobutamine stress parameters were similar for both studies. Although in TF study, the time between radiopharmaceutical injection and imaging was shorter than in MIBI study, there was no significant difference between heart-to-liver (H/Li) and heart-to-lung (H/Lu) ratios. According to CA results, diagnostic accuracy was similar for TF and MIBI. While sensitivity, specificity and accuracy for TF study were calculated as 82%, 84% and 82%, respectively, the corresponding values for MIBI were 82%, 88% and 84%, respectively. This clinical study has shown comparable diagnostic performance for the detection of CAD between MIBI and TF. Good correlation was found between segmental analysis for both studies. MIBI and TF showed similar perfusion defects and good segmental correlation during dobutamine stress with the same quality images. Both radiopharmaceuticals may be acceptable with this imaging protocol

  5. Effect of contrast material on image noise and radiation dose in adult chest computed tomography using automatic exposure control: A comparative study between 16-, 64- and 128-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jijo, E-mail: jijopaul1980@gmail.com [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Haus 23C UG, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Goethe University, Department of Biophysics, Max von Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Schell, Boris, E-mail: boris.schell@googlemail.com [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Haus 23C UG, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Kerl, J. Matthias, E-mail: matthias.kerl@gmai.com [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Haus 23C UG, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Maentele, Werner, E-mail: maentele@biophysik.uni-frankfurt.de [Goethe University, Department of Biophysics, Max von Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Vogl, Thomas J., E-mail: t.vogl@em.uni-frankfurt.de [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Haus 23C UG, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Bauer, Ralf W., E-mail: ralfwbauer@aol.com [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Haus 23C UG, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2011-08-15

    Purpose: To determine the difference in radiation dose between non-enhanced (NECT) and contrast-enhanced (CECT) chest CT examinations contributed by contrast material with different scanner generations with automatic exposure control (AEC). Methods and materials: Each 42 adult patients received a NECT and CECT of the chest in one session on a 16-, 64- or 128-slice CT scanner with the same scan protocol settings. However, AEC technology (Care Dose 4D, Siemens) underwent upgrades in each of the three scanner generations. DLP, CTDIvol and image noise were compared. Results: Although absolute differences in image noise were very small and ranged between 10 and 13 HU for NECT and CECT in median, the differences in image noise and dose (DLP: 16-slice:+2.8%; 64-slice:+3.9%; 128-slice:+5.6%) between NECT and CECT were statistically significant in all groups. Image noise and dose parameters were significantly lower in the most recent 128-slice CT generation for both NECT and CECT (DLP: 16-slice:+35.5-39.2%; 64-slice:+6.8-8.5%). Conclusion: The presence of contrast material lead to an increase in dose for chest examinations in three CT generations with AEC. Although image noise values were significantly higher for CECT, the absolute differences were in a range of 3 HU. This can be regarded as negligible, thus indicating that AEC is able to fulfill its purpose of maintaining image quality. However, technological developments lead to a significant reduction of dose and image noise with the latest CT generation.

  6. Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT: Experimental study using chest phantom

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Kono, Atsushi A.; Kusaka, Akiko; Konishi, Minoru; Yoshii, Masaru; Sugimura, Kazuro

    2010-01-01

    Purpose: The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT. Materials and methods: A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard (A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A. Results: Kappa values (κ) of overall identification and image qualities were substantial or almost perfect (0.60 < κ). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05). Conclusion: Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination.

  7. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  8. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    International Nuclear Information System (INIS)

    Palas, J.; Matos, A.P.; Ramalho, M.; Mascarenhas, V.; Heredia, V.

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  9. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  10. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  11. Comparative assessment of 18F-fluorodeoxyglucose PET and 99mTc-tetrofosmin SPECT for the prediction of functional recovery in patients with reperfused acute myocardial infarction

    International Nuclear Information System (INIS)

    Shirasaki, Haruhisa; Nakano, Akira; Uzui, Hiroyasu; Ueda, Takanori; Lee, Jong-Dae; Yonekura, Yoshiharu; Okazawa, Hidehiko

    2006-01-01

    Purpose: Although preserved glucose metabolism is considered to be a marker of myocardial viability in the chronic stage, it has not been fully elucidated whether this is also true with regard to reperfused acute myocardial infarction (AMI). The aim of this study was to compare the diagnostic performance of 99m Tc-tetrofosmin SPECT and 18 F-fluorodeoxyglucose (FDG) PET for the prediction of functional recovery in reperfused AMI.Methods: The study population comprised 28 patients. Both tetrofosmin SPECT and FDG PET were performed in all 28 patients at ca. 2 weeks and in 23 at 6 months. The tetrofosmin and FDG findings in infarct-related segments were compared with the regional wall motion score assessed by left ventriculography over 6 months to determine the predictive value for functional recovery. Of 120 infarct-related segments, 83 had preserved flow (tetrofosmin uptake ≥50%) and 81 had preserved glucose metabolism (FDG uptake ≥40%). The sensitivity and specificity of tetrofosmin SPECT for the prediction of functional recovery tended to be superior to those of FDG PET (90.0% and 72.5% vs 85.0% and 67.5%, respectively). Thirteen segments with preserved flow and decreased glucose metabolism demonstrated marked recovery of contractile function from 2.5±1.0 to 1.4±1.4 (p<0.01), with restoration of glucose metabolism at 6 months. In contrast, 11 segments with decreased flow and preserved glucose metabolism demonstrated incomplete functional improvement from 3.0±0.8 to 2.2±1.2. In the subacute phase, preserved myocardial blood flow is more reliable than glucose metabolism in predicting functional recovery in reperfused myocardium. (orig.)

  12. Anteroposterior chest radiograph vs. chest CT scan in early detection of pneumothorax in trauma patients

    Directory of Open Access Journals (Sweden)

    Omar Hesham R

    2011-09-01

    Full Text Available Abstract Pneumothorax is a common complication following blunt chest wall trauma. In these patients, because of the restrictions regarding immobilization of the cervical spine, Anteroposterior (AP chest radiograph is usually the most feasible initial study which is not as sensitive as the erect chest X-ray or CT chest for detection of a pneumothorax. We will present 3 case reports which serve for better understanding of the entity of occult pneumothorax. The first case is an example of a true occult pneumothorax where an initial AP chest X-ray revealed no evidence of pneumothorax and a CT chest immediately performed revealed evidence of pneumothorax. The second case represents an example of a missed rather than a truly occult pneumothorax where the initial chest radiograph revealed clues suggesting the presence of pneumothorax which were missed by the reading radiologist. The third case emphasizes the fact that "occult pneumothorax is predictable". The presence of subcutaneous emphesema and pulmonary contusion should call for further imaging with CT chest to rule out pneumothorax. Thoracic CT scan is therefore the "gold standard" for early detection of a pneumothorax in trauma patients. This report aims to sensitize readers to the entity of occult pneumothorax and create awareness among intensivists and ER physicians regarding the proper diagnosis and management.

  13. Anteroposterior chest radiograph vs. chest CT scan in early detection of pneumothorax in trauma patients.

    Science.gov (United States)

    Omar, Hesham R; Mangar, Devanand; Khetarpal, Suneel; Shapiro, David H; Kolla, Jaya; Rashad, Rania; Helal, Engy; Camporesi, Enrico M

    2011-09-27

    Pneumothorax is a common complication following blunt chest wall trauma. In these patients, because of the restrictions regarding immobilization of the cervical spine, Anteroposterior (AP) chest radiograph is usually the most feasible initial study which is not as sensitive as the erect chest X-ray or CT chest for detection of a pneumothorax. We will present 3 case reports which serve for better understanding of the entity of occult pneumothorax. The first case is an example of a true occult pneumothorax where an initial AP chest X-ray revealed no evidence of pneumothorax and a CT chest immediately performed revealed evidence of pneumothorax. The second case represents an example of a missed rather than a truly occult pneumothorax where the initial chest radiograph revealed clues suggesting the presence of pneumothorax which were missed by the reading radiologist. The third case emphasizes the fact that "occult pneumothorax is predictable". The presence of subcutaneous emphesema and pulmonary contusion should call for further imaging with CT chest to rule out pneumothorax. Thoracic CT scan is therefore the "gold standard" for early detection of a pneumothorax in trauma patients. This report aims to sensitize readers to the entity of occult pneumothorax and create awareness among intensivists and ER physicians regarding the proper diagnosis and management.

  14. Early appearance of SARS on chest CT scan

    International Nuclear Information System (INIS)

    Cheng Xiaoguang; Feng Suchen; Xia Guoguang; Zhao Tao; Gu Xiang; Qu Hui

    2003-01-01

    Objective: To evaluate the early appearance of SARS on chest CT scan and its role in the early diagnosis. Methods: Forty cases of SARS in keeping with the criteria of the Ministry of Health had chest CT scans within 7 days of onset of symptoms, and CR chest X-ray films were available as well. These chest X-rays and CT images were retrospectively reviewed to determine if there were any abnormalities on the images. The lesions on the chest CT images were then further analyzed in terms of the number, location, size, and density. Results: Positive abnormalities on chest CT scans were revealed in all 40 SARS cases. Positive findings on CR chest films were showed in only 25 cases, equivocal in 6, and normal in 9 cases. The main abnormalities seen on CT and X-rays were pulmonary infiltrations varied markedly in severity. 70 % cases had 1 or 2 lesions on chest CT scan, 30 % cases had 3 or more lesions. The lesions seen on chest CT scan tended to be ground-glass opacification, sometimes with consolidation which was very faint and inhomogeneous, easily missed on chest X-rays. Typically the lesions were located in the periphery of the lung, or both central and peripheral lung, but very rare in a pure central location. They were commonly in the shape of patch or ball. Conclusions: Chest CT scan is much more sensitive in detecting the lesions of the lung in SARS. The early appearance of SARS on chest CT scan is characteristic but non-specific, indicating that chest CT scan plays a very important role in the early diagnosis and differential diagnosis of SARS

  15. Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose{sup 4}™

    Energy Technology Data Exchange (ETDEWEB)

    Laqmani, Azien, E-mail: a.laqmani@uke.de [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Avanesov, Maxim; Butscheidt, Sebastian; Kurfürst, Maximilian [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Sehner, Susanne [Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Schmidt-Holtz, Jakob; Derlin, Thorsten; Behzadi, Cyrus [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Nagel, Hans D. [Science & Technology for Radiology, Fritz-Reuter-Weg 5f, 21244 Buchholz, Germany, (Germany); Adam, Gerhard; Regier, Marc [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany)

    2016-11-15

    Objective: To compare both image quality and visibility of normal and abnormal findings at submillisievert chest CT (smSv-CT) using filtered back projection (FBP) and the two different iterative reconstruction (IR) techniques iterative model reconstruction (IMR) and iDose{sup 4}™. Materials and methods: This institutional review board approved study was based on retrospective interpretation of clinically indicated acquired data. The requirement to obtain informed consent was waived. 81 patients with suspected pneumonia underwent smSv-CT (Brilliance iCT, Philips Healthcare; mean effective dose: 0.86 ± 0.2 mSv). Data were reconstructed using FBP and two different IR techniques iDose{sup 4}™ and IMR (Philips Healthcare) at various iteration levels. Objective image noise (OIN) was measured. Two experienced readers independently assessed all images for image noise, image appearance and visibility of normal anatomic and abnormal findings. A random intercept model was used for statistical analysis. Results: Compared to FBP and iDose{sup 4}™, IMR reduced OIN up to 88% and 72%, respectively (p < 0.001). A mild blotchy image appearance was seen in IMR images, affecting diagnostic confidence. iDose{sup 4}™ images provided satisfactory to good image quality for visibility of normal and abnormal findings and were superior to FBP (p < 0.001). IMR images were significantly inferior for visibility of normal structures compared to iDose{sup 4}™, while being superior for visibility of abnormal findings except for reticular pattern (p < 0.001). Conclusion: IMR results for visibility of normal and abnormal lung findings are heterogeneous, indicating that IMR may not represent a priority technique for clinical routine. iDose{sup 4}™ represents a suitable method for evaluation of lung tissue at submillisievert chest CT.

  16. Radiology illustrated. Chest radiology

    International Nuclear Information System (INIS)

    Lee, Kyung Soo; Han, Joungho; Chung, Man Pyo; Jeong, Yeon Joo

    2014-01-01

    Pattern approach to the diagnosis of lung diseases based on CT scan appearances. Guide to quick and reliable differential diagnosis. CT-pathology correlation. Emphasis on state-of-the-art MDCT. The purpose of this atlas is to illustrate how to achieve reliable diagnoses when confronted by the different abnormalities, or ''disease patterns'', that may be visualized on CT scans of the chest. The task of pattern recognition has been greatly facilitated by the advent of multidetector CT (MDCT), and the focus of the book is very much on the role of state-of-the-art MDCT. A wide range of disease patterns and distributions are covered, with emphasis on the typical imaging characteristics of the various focal and diffuse lung diseases. In addition, clinical information relevant to differential diagnosis is provided and the underlying gross and microscopic pathology is depicted, permitting CT-pathology correlation. The entire information relevant to each disease pattern is also tabulated for ease of reference. This book will be an invaluable handy tool that will enable the reader to quickly and easily reach a diagnosis appropriate to the pattern of lung abnormality identified on CT scans.

  17. Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xinming; Shaw, Chris C.; Lai, Chao-Jen; Wang Tianpeng [Department of Imaging Physics, Digital Imaging Research Laboratory, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2011-01-15

    Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full

  18. Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

    International Nuclear Information System (INIS)

    Liu Xinming; Shaw, Chris C.; Lai, Chao-Jen; Wang Tianpeng

    2011-01-01

    Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full

  19. Uso da cintilografia miocárdica em repouso durante dor torácica para descartar infarto agudo do miocárdio Utilización de la centellografía miocárdica en reposo durante dolor torácico para descartar infarto agudo de miocardio Use of resting myocardial scintigraphy during chest pain to exclude diagnosis of acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Gustavo Borges Barbirato

    2009-04-01

    miocardio. MÉTODOS: Un total de 108 pacientes ingresados con dolor torácico, o hasta tras 4 horas del término de los síntomas, con electrocardiograma no diagnostico, realizaron centellografía en reposo y dosificaciones de troponina I. No se excluyeron a los pacientes con pasado de infarto de miocardio (IM (24 pacientes. Se dosificó troponina I al ingreso y tras 6 horas del ingreso. Médicos nucleares realizaron análisis ciego de las imágenes. Se confirmó infarto de miocardio, con elevación de la troponina I mayor que tres veces el control. RESULTADOS: La imagen de perfusión en reposo se mostró anormal en todos los seis pacientes con IM. Sólo un paciente presentó imagen normal y elevación de la troponina. Otros 55 pacientes obtuvieron imagen positiva sin IM y 46 pacientes presentaron imágenes y troponinas normales. La prevalencia de la enfermedad fue de un 6,5%. Fue de un 85,7% la sensibilidad de la imagen de reposo durante dolor torácico para la evidencia de IM, y la especificidad de un 45,5%. El valor predictivo negativo fue de un 97,7%. CONCLUSIÓN: Pacientes sometidos al protocolo de dolor torácico con centellografía de perfusión miocárdica demostraron un excelente valor predictivo negativo para la exclusión del diagnóstico de infarto de miocardio. Estos resultados sugieren que la imagen de perfusión en reposo es una herramienta importante en la unidad de dolor torácico.BACKGROUND: Images of myocardial perfusion taken during an episode of chest pain have been used for patients in the emergency department. OBJECTIVE: To evaluate the operating characteristics of 99mTc-Tetrofosmin scintigraphy during an episode of chest pain to exclude the diagnosis of acute myocardial infarction. METHODS: One hundred and eight patients admitted with chest pain, or up to four hours after the end of symptoms and nondiagnostic electrocardiogram, underwent resting scintigraphy and measurement of troponin I concentrations. Patients with a history of myocardial

  20. Image quality and dose analysis for a PA chest X-ray: Comparison between AEC mode acquisition and manual mode using the 10 kVp ‘rule’

    International Nuclear Information System (INIS)

    Reis, Cláudia; Gonçalves, João; Klompmaker, Corrie; Bárbara, Ana Rita; Bloor, Chloe; Hegarty, Ryan; Lagrange, Tania; Temming, Noëlle; Sønnesyn, Mathilde; Røkeness, Henriette; Yamasathien, Amandine; Hogg, Peter

    2014-01-01

    Purpose: To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method: 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results: Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion: In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality

  1. Pulmonary nodule size evaluation with chest tomosynthesis.

    Science.gov (United States)

    Johnsson, Åse A; Fagman, Erika; Vikgren, Jenny; Fisichella, Valeria A; Boijsen, Marianne; Flinck, Agneta; Kheddache, Susanne; Svalkvist, Angelica; Båth, Magnus

    2012-10-01

    To evaluate intra- and interobserver variability, as well as agreement for nodule size measurements on chest tomosynthesis and computed tomographic (CT) images. The Regional Ethical Review Board approved this study, and all participants gave written informed consent. Thirty-six segmented nodules in 20 patients were included in the study. Eight observers measured the left-to-right, inferior-to-superior, and longest nodule diameters on chest tomosynthesis and CT images. Intra- and interobserver repeatability, as well as agreement between measurements on chest tomosynthesis and CT images, were assessed as recommended by Bland and Altman. The difference between the mean manual and the segmented diameter was -2.2 and -2.3 mm for left-to-right and -2.6 and -2.2 mm for the inferior-to-superior diameter for measurements on chest tomosynthesis and CT images, respectively. Intraobserver 95% limits of agreement (LOA) for the longest diameter ranged from a lower limit of -1.1 mm and an upper limit of 1.0 mm to -1.8 and 1.8 mm for chest tomosynthesis and from -0.6 and 0.9 mm to -3.1 and 2.2 mm for axial CT. Interobserver 95% LOA ranged from -1.3 and 1.5 mm to -2.0 and 2.1 mm for chest tomosynthesis and from -1.8 and 1.1 mm to -2.2 and 3.1 mm for axial CT. The 95% LOA concerning the mean of the observers' measurements of the longest diameter at chest tomosynthesis and axial CT were ±2.1 mm (mean measurement error, 0 mm). For the different observers, the 95% LOA between the modalities ranged from -2.2 and 1.6 mm to -3.2 and 2.8 mm. Measurements on chest tomosynthesis and CT images are comparable, because there is no evident bias between the modalities and the repeatability is similar. The LOA between measurements for the two modalities raise concern if measurements from chest tomosynthesis and CT were to be used interchangeably. © RSNA, 2012.

  2. Chest x-ray

    Science.gov (United States)

    ... pain from a chest injury (with a possible rib fracture or lung complication) or from heart problems Coughing ... arteries Evidence of heart failure In the bones: Fractures or other problems of the ribs and spine Osteoporosis

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... evaluate shortness of breath, persistent cough, fever, chest pain or injury. It may also be useful to ... of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. For more information about ...

  4. MRI of the Chest