WorldWideScience

Sample records for tethered pnipaam brushes

  1. Hairy polyelectrolyte brushes-grafted thermosensitive microgels as artificial synovial fluid for simultaneous biomimetic lubrication and arthritis treatment.

    Science.gov (United States)

    Liu, Guoqiang; Liu, Zhilu; Li, Na; Wang, Xiaolong; Zhou, Feng; Liu, Weimin

    2014-11-26

    We report the fabrication of poly(3-sulfopropyl methacrylate potassium salt) (PSPMK) brushes grafted poly(N-isopropylacrylamide) (PNIPAAm) microgels and their potential as artificial synovial fluid for biomimetic aqueous lubrication and arthritis treatment. The negatively charged PSPMK brushes and thermosensitive PNIPAAm microgels play water-based hydration lubrication and temperature-triggered drug release, respectively. Under soft friction pairs, an ultralow coefficient of friction was achieved, while the hairy thermosensitive microgels showed a desirable temperature-triggered drugs release performance. Such a soft charged hairy microgel offers great possibility for designing intelligent synovial fluid. What is more, the combination of lubrication and drug loading capabilities enables the large clinical potential of novel soft hairy nanoparticles as synthetic joint lubricant fluid in arthritis treatment.

  2. PNIPAAM modified mesoporous hydroxyapatite for sustained osteogenic drug release and promoting cell attachment

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tao [The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, 237 Luoyu Road, Wuhan 430079 (China); Tan, Lei [Key Laboratory of Biomedical Polymers of Ministry of Education, College of Chemistry and Molecular Science, Wuhan University, Wuhan 430072 (China); Cheng, Ning; Yan, Qi; Zhang, Yu-Feng [The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, 237 Luoyu Road, Wuhan 430079 (China); Liu, Chuan-Jun, E-mail: cjliu@whu.edu.cn [Key Laboratory of Biomedical Polymers of Ministry of Education, College of Chemistry and Molecular Science, Wuhan University, Wuhan 430072 (China); Shi, Bin, E-mail: shibin_dentist@126.com [The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, 237 Luoyu Road, Wuhan 430079 (China)

    2016-05-01

    This work presented a sustained release system of simvastatin (SIM) based on the mesoporous hydroxyapatite (MHA) capped with poly(N-isopropylacrylamide) (PNIPAAM). The MHA was prepared by using cetyltrimethylammonium bromide (CTAB) as a template and the modified PNIPAAM layer on the surface of MHA was fabricated through surface-initiated atom transfer radical polymerization (SI-ATRP). The SIM loaded MHA-PNIPAAM showed a sustained release of SIM at 37 °C over 16 days. The bone marrow mesenchymal stem cell (BMSC) proliferation was assessed by cell counting kit-8 (CCK-8) assay, and the osteogenic differentiation was evaluated by alkaline phosphatase (ALP) activity and Alizarin Red staining. The release profile showed that the release of SIM from MHA-SIM-PNIPAAM lasted 16 days and the cumulative amount of released SIM was almost seven-fold than MHA-SIM. Besides, SIM loaded MHA-PNIPAAM exhibited better performance on cell proliferation, ALP activity, and calcium deposition than pure MHA due to the sustained release of SIM. The quantity of ALP in MHA-SIM-PNIPAAM group was more than two fold than pure MHA group at 7 days. Compared to pure MHA, better BMSC attachment on PNIPAAM modified MHA was observed using fluorescent microscopy, indicating the better biocompatibility of MHA-PNIPAAM. - Highlights: • PNIPAAM modified mesoporous hydroxyapatite (MHA) was fabricated by SI-ATRP. • SIM loaded MHA-PNIPAAM continually released SIM in effect concentration for 16 days. • MHA-SIM-PNIPAAM behaved well on cell proliferation, ALP activity and calcium deposition.

  3. PNIPAAm-grafted thermoresponsive microcarriers: Surface-initiated ATRP synthesis and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Çakmak, Soner [Nanotechnology and Nanomedicine Department, Hacettepe University, 06800, Beytepe, Ankara (Turkey); Çakmak, Anıl S. [Bioengineering Department, Hacettepe University, 06800, Beytepe, Ankara (Turkey); Gümüşderelioğlu, Menemşe, E-mail: menemse@hacettepe.edu.tr [Nanotechnology and Nanomedicine Department, Hacettepe University, 06800, Beytepe, Ankara (Turkey); Bioengineering Department, Hacettepe University, 06800, Beytepe, Ankara (Turkey); Chemical Engineering Department, Hacettepe University, 06800, Beytepe, Ankara (Turkey)

    2013-07-01

    In this study, we developed novel thermoresponsive microcarriers as a powerful tool for cell culture and tissue engineering applications. For this purpose, two types of commercially available spherical microparticles (approximately 100 μm in diameter), dextran-based Sephadex® and vinyl acetate-based VA-OH (Biosynth®), were used and themoresponsive poly(N-isopropylacrylamide) (PNIPAAm) was grafted to the beads' surfaces by surface-initiated atom transfer radical polymerization (SI-ATRP). Initially, hydroxyl groups of microbeads were reacted with 2-bromopropionyl bromide to form ATRP macroinitiator. Then, NIPAAm was successfully polymerized from the initiator attached microbeads by ATRP with CuBr/2,2′-dipyridyl, catalyst complex. Furthermore, grafted and ungrafted microbeads were characterized by attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, scanning electron microscope (SEM), atomic force microscopy (AFM) and electron spectroscopy for chemical analysis (ESCA). The results of characterization studies confirmed that PNIPAAm was successfully grafted onto both dextran and vinyl acetate-based beads by means of ATRP reaction and thus, grafted microbeads gained thermoresponsive characteristics which will be evaluated for cell harvesting in further studies. Highlights: • PNIPAAm was grafted to the hydroxyl group carrying polymer beads by SI-ATRP. • Dex-g-PNIPAAm and VA-OH-g-PNIPAAm beads exhibited thermoresponsive characteristics. • They are appropriate candidates for microcarrier-facilitated cell cultures.

  4. PNIPAAm-grafted thermoresponsive microcarriers: Surface-initiated ATRP synthesis and characterization

    International Nuclear Information System (INIS)

    Çakmak, Soner; Çakmak, Anıl S.; Gümüşderelioğlu, Menemşe

    2013-01-01

    In this study, we developed novel thermoresponsive microcarriers as a powerful tool for cell culture and tissue engineering applications. For this purpose, two types of commercially available spherical microparticles (approximately 100 μm in diameter), dextran-based Sephadex® and vinyl acetate-based VA-OH (Biosynth®), were used and themoresponsive poly(N-isopropylacrylamide) (PNIPAAm) was grafted to the beads' surfaces by surface-initiated atom transfer radical polymerization (SI-ATRP). Initially, hydroxyl groups of microbeads were reacted with 2-bromopropionyl bromide to form ATRP macroinitiator. Then, NIPAAm was successfully polymerized from the initiator attached microbeads by ATRP with CuBr/2,2′-dipyridyl, catalyst complex. Furthermore, grafted and ungrafted microbeads were characterized by attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, scanning electron microscope (SEM), atomic force microscopy (AFM) and electron spectroscopy for chemical analysis (ESCA). The results of characterization studies confirmed that PNIPAAm was successfully grafted onto both dextran and vinyl acetate-based beads by means of ATRP reaction and thus, grafted microbeads gained thermoresponsive characteristics which will be evaluated for cell harvesting in further studies. Highlights: • PNIPAAm was grafted to the hydroxyl group carrying polymer beads by SI-ATRP. • Dex-g-PNIPAAm and VA-OH-g-PNIPAAm beads exhibited thermoresponsive characteristics. • They are appropriate candidates for microcarrier-facilitated cell cultures

  5. Selective adsorption of oppositely charged PNIPAAM on halloysite surfaces: a route to thermo-responsive nanocarriers.

    Science.gov (United States)

    Cavallaro, Giuseppe; Lazzara, Giuseppe; Lisuzzo, Lorenzo; Milioto, Stefana; Parisi, Filippo

    2018-05-17

    Halloysite nanotubes were functionalized with stimuli-responsive macromolecules to generate smart nanohybrids. Poly(N-isopropylacrylamide)-co-methacrylic acid (PNIPAAM-co-MA) was selectively adsorbed into halloysite lumen by exploiting electrostatic interactions. Amine-terminated PNIPAAM polymer was also investigated that selectively interacts with the outer surface of the nanotubes. The adsorption site has a profound effect on the thermodynamic behavior and therefore temperature responsive features of the hybrid material. The drug release kinetics was investigated by using Diclofenac as a non-steroidal anti-inflammatory drug model. The release kinetics depends on the nanoarchitecture of the PNIPAAM/Halloysite based material. In particular, diclofenac release was slowed down above the LCST for PNIPAAM-co-MA/Halloysite. Opposite trends occurred for Halloysite functionalized with PNIPAAM at the outer surface. This work represents a further step toward the opportunity to extend and control the delivery conditions of active species, which represent a key point in technological applications. © 2018 IOP Publishing Ltd.

  6. Regulating drug release from pH- and temperature-responsive electrospun CTS-g-PNIPAAm/poly(ethylene oxide) hydrogel nanofibers

    International Nuclear Information System (INIS)

    Yuan, Huihua; Li, Biyun; Liang, Kai; Lou, Xiangxin; Zhang, Yanzhong

    2014-01-01

    Temperature- and pH-responsive polymers have been widely investigated as smart drug release systems. However, dual-sensitive polymers in the form of nanofibers, which is advantageous in achieving rapid transfer of stimulus to the smart polymeric structures for regulating drug release behavior, have rarely been explored. In this study, chitosan-graft-poly(N-isopropylacrylamide) (CTS-g-PNIPAAm) copolymer was synthesized by using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxy succinimide (NHS) as grafting agents to graft carboxyl-terminated PNIPAAm (PNIPAAm-COOH) chains onto the CTS biomacromolecules, and then CTS-g-PNIPAAm with or without bovine serum albumin (BSA) was fabricated into nanofibers through electrospinning using poly(ethylene oxide) (PEO, 10 wt%) as a fiber-forming facilitating additive. The BSA laden CTS-g-PNIPAAm/PEO hydrogel nanofibers were tested to determine their drug release profiles by varying pH and temperature. Finally, cytotoxicity of the CTS-g-PNIPAAm/PEO hydrogel nanofibers was evaluated by assaying the L929 cell proliferation using the MTT method. It was found that the synthesized CTS-g-PNIPAAm possessed a temperature-induced phase transition and lower critical solution temperature (LCST) at 32° C in aqueous solutions. The rate of BSA release could be well modulated by altering the environmental pH and temperature of the hydrogel nanofibers. The CTS-g-PNIPAAm/PEO hydrogel nanofibers supported L929 cell growth, indicative of appropriate cytocompatibility. Our current work could pave the way towards developing multi-stimuli responsive nanofibrous smart materials for potential applications in the fields of drug delivery and tissue engineering. (paper)

  7. Thermoresponsive PNIPAAm-modified cotton fabric surfaces that switch between superhydrophilicity and superhydrophobicity

    International Nuclear Information System (INIS)

    Jiang Cheng; Wang Qihua; Wang Tingmei

    2012-01-01

    Thermoresponsive poly(N-isopropylacrylamide) (PNIPAAm) was grafted onto the cotton fabric by atom transfer radical polymerization (ATRP). Introducing 1H,1H,2H,2H-perfluorodecyltriethoxysilane (PFDTS) onto the surface, the density of PNIPAAm chains can be adjusted because of the competitive reactions of (3-aminopropyl) triethoxysilane (APS) and PFDTS. With the appropriate ratio of APS and PFDTS, the cotton fabric can be switched from superhydrophilic to superhydrophobic by controlling temperature. The prepared cotton fabric may find application in functional textiles, soft and folding superhydrophobic materials.

  8. Polyelectrolyte brushes in mixed ionic medium studied via intermolecular forces

    Science.gov (United States)

    Farina, Robert; Laugel, Nicolas; Pincus, Philip; Tirrell, Matthew

    2011-03-01

    The vast uses and applications of polyelectrolyte brushes make them an attractive field of research especially with the growing interest in responsive materials. Polymers which respond via changes in temperature, pH, and ionic strength are increasingly being used for applications in drug delivery, chemical gating, etc. When polyelectrolyte brushes are found in either nature (e.g., surfaces of cartilage and mammalian lung interiors) or commercially (e.g., skin care products, shampoo, and surfaces of medical devices) they are always surrounded by mixed ionic medium. This makes the study of these brushes in varying ionic environments extremely relevant for both current and future potential applications. The polyelectrolyte brushes in this work are diblock co-polymers of poly-styrene sulfonate (N=420) and poly-t-butyl styrene (N=20) which tethers to a hydrophobic surface allowing for a purely thermodynamic study of the polyelectrolyte chains. Intermolecular forces between two brushes are measured using the SFA. As multi-valent concentrations are increased, the brushes collapse internally and form strong adhesion between one another after contact (properties not seen in a purely mono-valent environment).

  9. Polyacrylic acid polymer brushes as substrates for the incorporation of anthraquinone derivatives. Unprecedented application of decorated polymer brushes on organocatalysis

    Science.gov (United States)

    Ruiz-Muelle, Ana Belén; Contreras-Cáceres, Rafael; Oña-Burgos, Pascual; Rodríguez-Dieguez, Antonio; López-Romero, Juan Manuel; Fernández, Ignacio

    2018-01-01

    The synthesis of amino-terminated anthraquinone derivatives and their incorporation onto polymer brushes for the fabrication of silicon-based nanometric functional coatings are described for the first time. The general process involves the covalent grafting of anthraquinone 1 onto two different polymer-brushes by amidation reactions. They are composed by amino- and carboxy-terminated poly(acrylic acid) chains (PAA-NH2- and PAA-COOH, respectively) tethered by one end to an underlying silicon oxide (SiO2) substrate in a polymer brush configuration. A third substrate is fabricated by UV induced hydrosilylation reaction using undecenoic acid as adsorbate on hydrogen-terminated Si(111) surfaces. One- and two-dimensional nuclear magnetic resonance (NMR), FT-IR, MS and X-ray diffraction (XRD) were used to characterize anthraquinone 1. Ellipsometric and X-ray photoelectron spectroscopy (XPS) measurements demonstrated the presence of the polymer brushes on the silicon wafers, and atomic force microscopy (AFM) was used to study its surface morphology. The covalent linkage between anthraquinone and polymer brushes was proven by XPS and confocal fluorescence microscopy. The resulting surfaces were assayed in the heterogenous organocatalytic transformation of (1H)-indole into 3-benzyl indole with moderate yields but with high recyclability.

  10. Interfacial Friction and Adhesion of Polymer Brushes

    KAUST Repository

    Landherr, Lucas J. T.

    2011-08-02

    A bead-probe lateral force microscopy (LFM) technique is used to characterize the interfacial friction and adhesion properties of polymer brushes. Our measurements attempt to relate the physical structure and chemical characteristics of the brush to their properties as thin-film, tethered lubricants. Brushes are synthesized at several chain lengths and surface coverages from polymer chains of polydimethylsiloxane (PDMS), polystyrene (PS), and a poly(propylene glycol)-poly(ethylene glycol) block copolymer (PPG/PEG). At high surface coverage, PDMS brushes manifest friction coefficients (COFs) that are among the lowest recorded for a dry lubricant film (μ ≈ 0.0024) and close to 1 order of magnitude lower than the COF of a bare silicon surface. Brushes synthesized from higher molar mass chains exhibit higher friction forces than those created using lower molar mass polymers. Increased grafting density of chains in the brush significantly reduces the COF by creating a uniform surface of stretched chains with a decreased surface viscosity. Brushes with lower surface tension and interfacial shear stresses manifest the lowest COF. In particular, PDMS chains exhibit COFs lower than PS by a factor of 3.7 and lower than PPG/PEG by a factor of 4.7. A scaling analysis conducted on the surface coverage (δ) in relation to the fraction (ε) of the friction force developing from adhesion predicts a universal relation ε ∼ δ4/3, which is supported by our experimental data. © 2011 American Chemical Society.

  11. Swelling and Shrinking Properties of Thermo-Responsive Polymeric Ionic Liquid Hydrogels with Embedded Linear pNIPAAM

    Directory of Open Access Journals (Sweden)

    Simon Gallagher

    2014-03-01

    Full Text Available In this study, varying concentrations of linear pNIPAAM have been incorporated for the first time into a thermo-responsive polymeric ionic liquid (PIL hydrogel, namely tributyl-hexyl phosphonium 3-sulfopropylacrylate (P-SPA, to produce semi-interpenetrating polymer networks. The thermal properties of the resulting hydrogels have been investigated along with their thermo-induced shrinking and reswelling capabilities. The semi-interpenetrating networks (IPN hydrogels were found to have improved shrinking and reswelling properties compared with their PIL counterpart. At elevated temperatures (50–80 °C, it was found that the semi-IPN with the highest concentration of hydrophobic pNIPAAM exhibited the highest shrinking percentage of ~40% compared to the conventional P-SPA, (27%. This trend was also found to occur for the reswelling measurements, with semi-IPN hydrogels producing the highest reswelling percentage of ~67%, with respect to its contracted state. This was attributed to an increase in water affinity due to the presence of hydrophilic pNIPAAM. Moreover, the presence of linear pNIPAAM in the polymer matrix leads to improved shrinking and reswelling response compared to the equivalent PIL.

  12. Molecular Velcro constructed from polymer loop brushes showing enhanced adhesion force

    Science.gov (United States)

    Zhou, Tian; Han, Biao; Han, Lin; Li, Christopher; Department of Materials Science; Engineering Team; School of Biomedical Engineering, Science; Health Systems Team

    2015-03-01

    Molecular Velcro is commonly seen in biological systems as the formation of strong physical entanglement at molecular scale could induce strong adhesion, which is crucial to many biological processes. To mimic this structure, we designed, and fabricated polymer loop brushes using polymer single crystals with desired surface functionality and controlled chain folding. Compared with reported loop brushes fabricated using triblock copolymers, the present loop bushes have precise loop sizes, loop grafting density, and well controlled tethering locations on the solid surface. Atomic force microscopy-based force spectroscopy measurements using a polymer chain coated probe reveal that the adhesion force are significantly enhanced on the loop brush surface as compared with its single-strand counterpart. This study directly shows the effect of polymer brush conformation on their properties, and suggests a promising strategy for advanced polymer surface design.

  13. Hidrogéis semi-IPN baseados em rede de alginato-Ca2+ com PNIPAAm entrelaçado: propriedades hidrofílicas, morfológicas e mecânicas Semi-IPN hydrogels based on alginate-Ca2+ network and PNIPAAm: hydrophilic, morphological and mechanical properties

    Directory of Open Access Journals (Sweden)

    Márcia R. de Moura

    2008-06-01

    Full Text Available Neste trabalho, a termossensibilidade dos hidrogéis do tipo semi-IPN baseados em rede de alginato-Ca2+com poli(N-isopropil acrilamida (PNIPAAm entrelaçado, com diferentes teores de alginato e de PNIPAAm, foi caracterizada por meio de medidas de grau de intumescimento (Q, microscopia eletrônica de varredura (MEV e propriedades mecânicas [tensão máxima de compressão (σ, densidade aparente de reticulação (νe e módulo de elasticidade (E]. Os valores de Q variam inversamente com νe. Para o parâmetro νe contribuem as concentrações de retículos alginato-Ca2+ e de cadeias de PNIPAAm. Hidrogéis com maiores valores de Q possuem maiores poros. Resultados de propriedades mecânicas demonstraram que hidrogéis com maior νe apresentam maior rigidez e resistência à compressão, sendo este efeito mais intenso acima da LCST do PNIPAAm. O controle dessas propriedades nesses hidrogéis termos-sensíveis torna esses materiais potencialmente viáveis para aplicação em sistemas carreadores para liberação controlada e/ou prolongada de fármacos e substratos para crescimento e cultura de célula.In this study, the thermosensitivity of semi-IPN hydrogels based on alginate-Ca2+ network and having PNIPAAm entangled was characterized by swelling degree (Q, scanning electron microscopy (SEM and mechanical properties [compressive stress (σ, apparent cross-linking density (νe and modulus of elasticity (E]. The Q values change inversely to the νe ones. The concentrations of the alginate-Ca2+ cross-linking and of the PNIPAAm chains contribute to the νe parameter. Higher values of Q correlate to larger pores size in the hydrogel. Hydrogels richer in alginate and PNIPAAm were more rigid, highly resistant to deformation because of their higher compressive modulus of elasticity. This is more intense at temperatures above the LCST of PNIPAAm in water (32-35 °C. The control of thermosensitive properties by tailoring the alginate-Ca2+/PNIPAAm ratio and

  14. Tethered Nanoparticle–Polymer Composites: Phase Stability and Curvature

    KAUST Repository

    Srivastava, Samanvaya

    2012-04-17

    Phase behavior of poly(ethylene glycol) (PEG) tethered silica nanoparticles dispersed in PEG hosts is investigated using small-angle X-ray scattering. Phase separation in dispersions of densely grafted nanoparticles is found to display strikingly different small-angle X-ray scattering signatures in comparison to phase-separated composites comprised of bare or sparsely grafted nanoparticles. A general diagram for the dispersion state and phase stability of polymer tethered nanoparticle-polymer composites incorporating results from this as well as various other contemporary studies is presented. We show that in the range of moderate to high grafting densities the dispersion state of nanoparticles in composites is largely insensitive to the grafting density of the tethered chains and chemistry of the polymer host. Instead, the ratio of the particle diameter to the size of the tethered chain and the ratio of the molecular weights of the host and tethered polymer chains (P/N) are shown to play a dominant role. Additionally, we find that well-functionalized nanoparticles form stable dispersions in their polymer host beyond the P/N limit that demarcates the wetting/dewetting transition in polymer brushes on flat substrates interacting with polymer melts. A general strategy for achieving uniform nanoparticle dispersion in polymers is proposed. © 2012 American Chemical Society.

  15. Mapping the location of grafted PNIPAAM in mesoporous SBA-15 silica using gas adsorption analysis

    DEFF Research Database (Denmark)

    Reichhardt, Nina Viola; Guillet-Nicolas, Rémy; Thommes, Matthias

    2012-01-01

    The thermoresponsive polymer poly-N-isopropylacrylamide (PNIPAAM) was grafted in mesoporous SBA-15 silica. The grafting process consists of three steps: (i) increasing the amount of surface silanol groups of SBA-15 by hydroxylation, (ii) attachment of an anchor (1-(trichlorosilyl)-2-(m/p- (chloro......The thermoresponsive polymer poly-N-isopropylacrylamide (PNIPAAM) was grafted in mesoporous SBA-15 silica. The grafting process consists of three steps: (i) increasing the amount of surface silanol groups of SBA-15 by hydroxylation, (ii) attachment of an anchor (1-(trichlorosilyl)-2-(m...

  16. The Art and Science of Polymer Brushes: Recent Developments in Patterning and Characterization Approaches.

    Science.gov (United States)

    Panzarasa, Guido

    2017-06-28

    Polymer brushes are dense arrays of macromolecular chains tethered by one end at a surface. They are at the cutting edge of polymer nanotechnology since the dawn of controlled surface-initiated polymerization techniques unlocked new prospects for the synthesis of polymer brushes with tailorable properties. More recently, thanks to the growing interest in the use of brushes for the generation of functional surfaces, the need for advanced patterning and characterization approaches rapidly increased. Meeting these needs requires the contribution of experts from different disciplines: polymer chemistry, surface science, electrochemistry and particle physics. The focus of this review is to highlight recent developments in the field of polymer brushes, specifically the application of photocatalytic lithography as a versatile patterning strategy, the study of grafted-from polymer brushes by electrochemical methods and, most importantly, the introduction of positron annihilation spectroscopy as a powerful technique for the investigation of the structure of polymer brushes and of their composites with nanoparticles.

  17. Determination of the optical properties of PNIPAAm gels used in biological applications

    CSIR Research Space (South Africa)

    Singh, A

    2009-07-01

    Full Text Available Poly(N-isopropylacrylamide) that is PNIPAAm is a temperature sensitive smart material which displays a lower critical solution temperature (LCST) at 33-35oC. At the lower critical solution temperature, the gel changes from hydrophilic to hydrophobic...

  18. Bottle-Brush Brushes: Cylindrical Molecular Brushes of Poly(2-oxazoline) on Glassy Carbon

    KAUST Repository

    Zhang, Ning; Steenackers, Marin; Luxenhofer, Robert; Jordan, Rainer

    2009-01-01

    We report on the synthesis of brushes of bottle-brushes of poly(2-oxazoline)s on polished glassy carbon (GC) substrates. First, homogeneous and stable poly(2-isopropenyl-2-oxazoline) (PIPOx) brush layers with thicknesses up to 160 nm were created directly onto GC by the self-initiated photografting and photopolymerization (SIPGP) of 2-isopropenyl-2-oxazoline (IPOx). Kinetic studies reveal a linear increase in thickness with the polymerization time. In a second reaction, the pendant 2-oxazoline ring of the PIPOx brushes were used for the living cationic ring-opening polymerization (LCROP) with different substituted 2-oxazoline monomers to form the side chains. Also for the second surface-initiatedLCROPfrom the surface-bound macroinitiator brushes, the thickness increase with the polymerization time was found to be linear and reproducible. Characterization of the resulting bottle-brush brushes by FTIR spectroscopy,contact angle, and AFM indicates a high side chain grafting density and quantitative reactions. Finally, we have demonstrated the possibility of functionalizing the bottle-brush brushes side chain end groups with sterically demanding molecules. © 2009 American Chemical Society.

  19. Bottle-Brush Brushes: Cylindrical Molecular Brushes of Poly(2-oxazoline) on Glassy Carbon

    KAUST Repository

    Zhang, Ning

    2009-07-28

    We report on the synthesis of brushes of bottle-brushes of poly(2-oxazoline)s on polished glassy carbon (GC) substrates. First, homogeneous and stable poly(2-isopropenyl-2-oxazoline) (PIPOx) brush layers with thicknesses up to 160 nm were created directly onto GC by the self-initiated photografting and photopolymerization (SIPGP) of 2-isopropenyl-2-oxazoline (IPOx). Kinetic studies reveal a linear increase in thickness with the polymerization time. In a second reaction, the pendant 2-oxazoline ring of the PIPOx brushes were used for the living cationic ring-opening polymerization (LCROP) with different substituted 2-oxazoline monomers to form the side chains. Also for the second surface-initiatedLCROPfrom the surface-bound macroinitiator brushes, the thickness increase with the polymerization time was found to be linear and reproducible. Characterization of the resulting bottle-brush brushes by FTIR spectroscopy,contact angle, and AFM indicates a high side chain grafting density and quantitative reactions. Finally, we have demonstrated the possibility of functionalizing the bottle-brush brushes side chain end groups with sterically demanding molecules. © 2009 American Chemical Society.

  20. Scaling features of the tribology of polymer brushes of increasing grafting density around the mushroom-to-brush transition.

    Science.gov (United States)

    Mayoral, E; Klapp, J; Gama Goicochea, A

    2017-01-01

    Nonequilibrium coarse-grained, dissipative particle dynamics simulations of complex fluids, made up of polymer brushes tethered to planar surfaces immersed in a solvent yield nonmonotonic behavior of the friction coefficient as a function of the polymer grating density on the substrates, Γ, while the viscosity shows a monotonically increasing dependence on Γ. This effect is shown to be independent of the degree of polymerization, N, and the size of the system. It arises from the composition and the structure of the first particle layer adjacent to each surface that results from the confinement of the fluid. Whenever such layers are made up of as close a proportion of polymer beads to solvent particles as there are in the fluid, the friction coefficient shows a minimum, while for disparate proportions the friction coefficient grows. At the mushroom-to-brush transition (MBT) the viscosity scales with an exponent that depends on the characteristic exponent of the MBT (6/5) and the solvent quality exponent (ν=0.5, for θsolvent), but it is independent of the polymerization degree (N). On the other hand, the friction coefficient at the MBT scales as μ∼N^{6/5}, while the grafting density at the MBT scales as Γ∼N^{-6/5} when friction is minimal, in agreement with previous scaling theories. We argue these aspects are the result of cooperative phenomena that have important implications for the understanding of biological brushes and the design of microfluidics devices, among other applications of current academic and industrial interest.

  1. IPN hydrogels based on PNIPAAm and PVA-Ma networks: characterization through measure of LCST, swelling ratio and mechanical properties - doi: 10.4025/actascitechnol.v34i2.15019

    Directory of Open Access Journals (Sweden)

    Adriana Cristina Wenceslau

    2012-03-01

    Full Text Available IPN hydrogels based on chemically modified poly(vinyl alcohol (or PVA-Ma, with different degrees of substitution (DS, and poly(N-isopropylacrylamide (or PNIPAAm were obtained and characterized through measures of LCST, swelling ratio and mechanical properties. Linear PVA-Ma with several DS were obtained through the chemical reaction of PVA with glycidyl methacrylate (GMA. The DS of various PVA-Ma were determined through 1H NMR spectroscopy. Two steps were used for preparation the PVA-Ma/PNIPAAm membrane hydrogels. In the first step the PVA-Ma hydrogels (using PVA-Ma with different DS were prepared by reaction of double bonds on PVA-Ma, using the persulfate/TEMED system. Using a photoreaction pathway in the second step, PNIPAAm network was prepared within the parent PVA-Ma network at different PVA-Ma/NIPAAm ratios. The studies show that degree of swelling ratio (SR of PVA-Ma/PNIPAAm IPN hydrogels is dependent of temperature. The LCST for each IPN-hydrogel was determined by measuring the intensity of light transmitted through the hydrogel. The LCST of the IPN hydrogels ranged from 34.6 to 38.1oC. The elastic modules of swollen IPN hydrogels increased from 25 to 35oC but decreased by further warming to 45oC. The LCST, swelling ratio and mechanical properties of PVA-Ma/PNIPAAm IPN hydrogels can be tailored by tuning the PVA-Ma/NIPAAm ratio.

  2. Tether dynamics and control results for tethered satellite system's initial flight

    Science.gov (United States)

    Chapel, Jim D.; Flanders, Howard

    The recent Tethered Satellite System-1 (TSS-1) mission has provided a wealth of data concerning the dynamics of tethered systems in space and has demonstrated the effectiveness of operational techniques designed to control these dynamics. In this paper, we review control techniques developed for managing tether dynamics, and discuss the results of using these techniques for the Tethered Satellite System's maiden flight on STS-46. In particular, the flight results of controlling libration dynamics, string dynamics, and slack tether are presented. These results show that tether dynamics can be safely managed. The overall stability of the system was found to be surprisingly good even at relatively short tether lengths. In fact, the system operated in passive mode at a tether length of 256 meters for over 9 hours. Only monitoring of the system was required during this time. Although flight anomalies prevented the planned deployment to 20 km, the extended operations at shorter tether lengths have proven the viability of using tethers in space. These results should prove invaluable in preparing for future missions with tethered objects in space.

  3. Durable and Washable Antibacterial Copper Nanoparticles Bridged by Surface Grafting Polymer Brushes on Cotton and Polymeric Materials

    Directory of Open Access Journals (Sweden)

    Chufeng Sun

    2018-01-01

    Full Text Available To increase the durability of antibacterial coating on cotton and polymeric substrates, surface initiated grafting polymer brushes are introduced onto the substrates surface to bridge copper nanoparticles coatings and substrate. The morphologies of the composites consisting of the copper nanoparticles and polymer brushes were characterized with scanning electron microscopy (SEM. It was found that copper nanoparticles were uniformly and firmly distributed on the surfaces of the substrates by the polymer brushes; meanwhile, the reinforced concrete-like structures were formed in the composite materials. The substrates coated by the copper nanoparticles showed the efficient antibacterial activity against Staphylococcus aureus (S. aureus and Escherichia coli (E. coli even after washing by 30 cycles. The copper nanoparticles were tethered on the substrates by the strong chemical bonds, which led to the excellent washable fitness and durability. The change of the phase structure of the copper was analyzed to investigate the release mechanism of copper ions.

  4. Self-consistent field theory of tethered polymers: one dimensional, three dimensional, strong stretching theories and the effects of excluded-volume-only interactions.

    Science.gov (United States)

    Suo, Tongchuan; Whitmore, Mark D

    2014-11-28

    We examine end-tethered polymers in good solvents, using one- and three-dimensional self-consistent field theory, and strong stretching theories. We also discuss different tethering scenarios, namely, mobile tethers, fixed but random ones, and fixed but ordered ones, and the effects and important limitations of including only binary interactions (excluded volume terms). We find that there is a "mushroom" regime in which the layer thickness is independent of the tethering density, σ, for systems with ordered tethers, but we argue that there is no such plateau for mobile or disordered anchors, nor is there one in the 1D theory. In the other limit of brushes, all approaches predict that the layer thickness scales linearly with N. However, the σ(1/3) scaling is a result of keeping only excluded volume interactions: when the full potential is included, the dependence is faster and more complicated than σ(1/3). In fact, there does not appear to be any regime in which the layer thickness scales in the combination Nσ(1/3). We also compare the results for two different solvents with each other, and with earlier Θ solvent results.

  5. Self-consistent field theory of tethered polymers: One dimensional, three dimensional, strong stretching theories and the effects of excluded-volume-only interactions

    International Nuclear Information System (INIS)

    Suo, Tongchuan; Whitmore, Mark D.

    2014-01-01

    We examine end-tethered polymers in good solvents, using one- and three-dimensional self-consistent field theory, and strong stretching theories. We also discuss different tethering scenarios, namely, mobile tethers, fixed but random ones, and fixed but ordered ones, and the effects and important limitations of including only binary interactions (excluded volume terms). We find that there is a “mushroom” regime in which the layer thickness is independent of the tethering density, σ, for systems with ordered tethers, but we argue that there is no such plateau for mobile or disordered anchors, nor is there one in the 1D theory. In the other limit of brushes, all approaches predict that the layer thickness scales linearly with N. However, the σ 1/3 scaling is a result of keeping only excluded volume interactions: when the full potential is included, the dependence is faster and more complicated than σ 1/3 . In fact, there does not appear to be any regime in which the layer thickness scales in the combination Nσ 1/3 . We also compare the results for two different solvents with each other, and with earlier Θ solvent results

  6. Polyelectrolyte Properties in Mono and Multi-Valent Ionic Media: Brushes and Complex Coacervates

    Science.gov (United States)

    Farina, Robert M.

    Materials composed of polyelectrolytes have unique and interesting physical properties resulting primarily from their charged monomer segments. Polyelectrolytes, which exist in many different biological and industrial forms, have also been shown to be highly responsive to external environmental changes. Here, two specific polyelectrolyte systems, brushes and complex coacervates, are discussed in regards to how their properties can be tailored by adjusting the surrounding ionic environment with mono and multi-valent ions. End-tethered polyelectrolyte brushes, which constitute an interesting and substantial portion of polyelectrolyte applications, are well known for their ability to provide excellent lubrication and low friction when coated onto surfaces (e.g. articular cartilage and medical devices), as well as for their ability to stabilize colloidal particles in solution (e.g. paint and cosmetic materials). These properties have been extensively studied with brushes in pure mono-valent ionic media. However, polyelectrolyte brush interactions with multi-valent ions in solution are much less understood, although highly relevant considering mono and multi-valent counterions are present in most applications. Even at very low concentrations of multi-valent ions in solution, dramatic polyelectrolyte brush physical property changes can occur, resulting in collapsed chains which also adhere to one another via multi-valent bridging. Here, the strong polyelectrolyte poly(sodium styrene sulfonate) was studied using the Surface Forces Apparatus (SFA) and electrochemistry in order to investigate brush height and intermolecular interactions between two brushes as a function of multi-valent counterion population inside a brush. Complex coacervates are formed when polyanions and polycations are mixed together in proper conditions of an aqueous solution. This mixing results in a phase separation of a polymer-rich, coacervate phase composed of a chain network held together via

  7. Differences between tethered polyelectrolyte chains adsorbed onto bare mica and hydrophobically modified mica, comparison with theory.

    Science.gov (United States)

    Balastre, Marc; Tamashiro, Mario N.; Hernandez, Ernesto; Pincus, Philip; Tirrell, Matthew

    2001-03-01

    End-grafted polymers generated from the adsorption of asymmetric diblock copolymers on solid surface play an important role in many areas of science and technology. While the small insoluble block acts as an anchor, the charged soluble block confers useful properties to the surface. This study looks at tethered layers of poly(styrene sulfonate)/poly(t-butyl styrene) (PtBS-PSS) adsorbed on both mica (hydrophilic) and octadecyltriethoxysilane (OTE) modified mica (hydrophobic). Normal compressing forces at two different constant grafting densities (bare and modified mica) were measured with the surface force apparatus and compared with theoretical prediction. The effect of salt concentration (Cs) upon the thickness of the self-assembled layers (Lo) was measured in each case. For adsorption of diblock copolymers onto OTE the resulting scaling relationship is much closer to the brush theory, Lo Cs-1/3. This result suggests that the adsorbed amount on mica is not high enough to form a brush.

  8. Tethers in Space

    Science.gov (United States)

    Johnson, Les; Bilén, Sven G.; Gilchrist, Brian E.; Krause, Linda Habash

    2017-09-01

    This Special Section of Acta Astronautica contains several peer-reviewed papers selected from among those presented at the Fifth International Conference on Tethers in Space (TiS2016). After a hiatus of 21 years since the last Conference on Tethers in Space, TiS2016 brought together experts, practitioners, and other interested in space tethers and related fields. TiS2016 was held May 24-26, 2016 at The University of Michigan in Ann Arbor, Michigan, U.S.A. Leveraging the hard work of a great many volunteers, the conference co-chairs Prof. Brian Gilchrist and Prof. Sven Bilén welcomed an international contingent with authors from the U.S., Canada, Japan, Spain, China, Finland, Estonia, and Italy. The community provided updates on what has transpired since their last gathering by providing lessons learned; describing new technologies and subsystems; and proposing new tether missions and applications. Papers overviewed de-orbit systems, power generation, orbital maneuvering, momentum capture, debris removal, space tugs, space elevators, collision avoidance, and tether dynamics, among others.

  9. Why Not Space Tethers?

    Science.gov (United States)

    Stone, Noble H.

    2007-01-01

    The Tethered Satellite System Space Shuttle missions, TSS-1 in 1993 and TSS-1R in 1996, were the height of space tether technology development. Since NASA's investment of some $200M and two Shuttle missions in those two pioneering missions, there have been several smaller tether flight experiments, but interest in this promising technology has waned within NASA as well as the DOD agencies. This is curious in view of the unique capabilities of space tether systems and the fact that they have been flight validated and shown to perform as, or better than, expected in earth orbit. While it is true that the TSS-1, TSS-1R and SEDS-2 missions experienced technical difficulties, the causes of these early developmental problems are now known to be design or materials flaws that are (1) unrelated to the basic viability of space tether technology, and (2) they are readily corrected. The purpose of this paper is to review the dynamic and electrodynamic fundamentals of space tethers and the unique capabilities they afford (that are enabling to certain types of space missions); to elucidate the nature, cause, and solution of the early developmental problems; and to provide an update on progress made in development of the technology. Finally, it is shown that (1) all problems experienced during early development of the technology now have solutions; and (2) the technology has been matured by advances made in strength and robustness of tether materials, high voltage engineering in the space environment, tether health and status monitoring, and the elimination of the broken tether hazard. In view of this, it is inexplicable why this flight-validated technology has not been utilized in the past decade, considering the powerful and unique capabilities that space tethers can afford that are, not only required to carryout, otherwise, unobtainable missions, but can also greatly reduce the cost of certain on-going space operations.

  10. In-situ ATR-FTIR for characterization of thin biorelated polymer films

    International Nuclear Information System (INIS)

    Müller, M.; Torger, B.; Bittrich, E.; Kaul, E.; Ionov, L.; Uhlmann, P.; Stamm, M.

    2014-01-01

    We present and review in-situ-attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopic data from thin biorelated polymer films useful for the modification and functionalization of polymer and inorganic materials and discuss their applications related to life sciences. A special ATR mirror attachment operated by the single-beam-sample-reference (SBSR) concept and housing a homebuilt thermostatable flow cell was used, which allows for appropriate background compensation and signal to noise ratio. ATR-FTIR data on the reactive deposition of dopamine on inorganic model surfaces are shown. Information on the structure and deposition pathway for such bioinspired melanin-like films is provided. ATR-FTIR data on thermosensitive polymer brushes of poly(N-isopropylacrylamide) (PNIPAAM) is then presented. The thermotropic hydration and hydrogen bonding behavior of PNIPAAM brush films is described. Finally, ATR-FTIR data on biorelated polyelectrolyte multilayers (PEM) are given together with details on PEM growth and detection. Applications of these latter films for biopassivation/activation and local drug delivery are addressed

  11. Macroion induced dehydration of weak polyelectrolyte brushes

    Science.gov (United States)

    Zheng, Zhongli; Zhu, Y. Elaine

    2014-03-01

    The interaction of macroions, including polyelectrolytes, DNAs, and proteins, with polymer and cellular surfaces is critically related to many biomolecular activities, such as protein adsorption and DNA hybridization at probe surfaces. In an experimental approach to examine the macroion electrostatic interaction with a polymer surface while minimizing the long-debated hydrophobic interaction, we study the interaction of molybdenum-based inorganic polyoxometalate (POM) nanoclusters carrying 42 negative charges as model hydrophilic macroions with surface-tethered poly-2-vinylpyridine (P2VP) brushes immersed in aqueous solutions. By AFM, QCM, and contact goniometer, we have observed the collapse of P2VP chains by adding POM macroions at a constant pH. Surprisingly, added POM macroions can cause the shift of swollen-to-collapse transition pH to a lower value, in contrast to the shift to high pH value by adding simple monovalent salts. At sufficiently high POM concentration, a stable POM-P2VP composite layer, showing little dependence on solution pH and additional salts, can be formed, suggesting a simple route to construct meso-porous polymer membranes.

  12. Polymer Brushes

    NARCIS (Netherlands)

    Vos, de W.M.; Kleijn, J.M.; Keizer, de A.; Cosgrove, T.; Cohen Stuart, M.A.

    2010-01-01

    A polymer brush can be defined as a dense array of polymers end-attached to an interface that stretch out into the surrounding medium. Polymer brushes have been investigated for the past 30 years and have shown to be an extremely useful tool to control interfacial properties. This review is intended

  13. Biomolecule-functionalized polymer brushes.

    Science.gov (United States)

    Jiang, Hui; Xu, Fu-Jian

    2013-04-21

    Functional polymer brushes have been utilized extensively for the immobilization of biomolecules, which is of crucial importance for the development of biosensors and biotechnology. Recent progress in polymerization methods, in particular surface-initiated atom transfer radical polymerization (ATRP), has provided a unique means for the design and synthesis of new biomolecule-functionalized polymer brushes. This current review summarizes such recent research activities. The different preparation strategies for biomolecule immobilization through polymer brush spacers are described in detail. The functional groups of the polymer brushes used for biomolecule immobilization include epoxide, carboxylic acid, hydroxyl, aldehyde, and amine groups. The recent research activities indicate that functional polymer brushes become versatile and powerful spacers for immobilization of various biomolecules to maximize their functionalities. This review also demonstrates that surface-initiated ATRP is used more frequently than other polymerization methods in the designs of new biomolecule-functionalized polymer brushes.

  14. Tethering sockets and wrenches

    Science.gov (United States)

    Johnson, E. P.

    1990-01-01

    The tethering of sockets and wrenches was accomplished to improve the safety of working over motor segments. To accomplish the tethering of the sockets to the ratchets, a special design was implemented in which a groove was machined into each socket. Each socket was then fitted with a snap ring that can spin around the machined groove. The snap ring is tethered to the handle of the ratchet. All open end wrenches are also tethered to the ratchet or to the operator, depending upon the type. Tests were run to ensure that the modified tools meet torque requirements. The design was subsequently approved by Space Safety.

  15. Tethering sockets and wrenches

    Science.gov (United States)

    Johnson, E. P.

    1990-07-01

    The tethering of sockets and wrenches was accomplished to improve the safety of working over motor segments. To accomplish the tethering of the sockets to the ratchets, a special design was implemented in which a groove was machined into each socket. Each socket was then fitted with a snap ring that can spin around the machined groove. The snap ring is tethered to the handle of the ratchet. All open end wrenches are also tethered to the ratchet or to the operator, depending upon the type. Tests were run to ensure that the modified tools meet torque requirements. The design was subsequently approved by Space Safety.

  16. Experiments and Numerical Simulations of Electrodynamic Tether

    Science.gov (United States)

    Iki, Kentaro; Kawamoto, Satomi; Takahashi, Ayaka; Ishimoto, Tomori; Yanagida, Atsushi; Toda, Susumu

    As an effective means of suppressing space debris growth, the Aerospace Research and Development Directorate of the Japan Aerospace Exploration Agency (JAXA) has been investigating an active space debris removal system that employs highly efficient electrodynamic tether (EDT) technology for orbital transfer. This study investigates tether deployment dynamics by means of on-ground experiments and numerical simulations of an electrodynamic tether system. Some key parameters used in the numerical simulations, such as the elastic modulus and damping ratio of the tether, the spring constant of the coiling of the tether, and deployment friction, must be estimated, and various experiments are conducted to determine these values. As a result, the following values were obtained: The elastic modulus of the tether was 40 GPa, and the damping ratio of the tether was 0.02. The spring constant and the damping ratio of the tether coiling were 10-4 N/m and 0.025 respectively. The deployment friction was 0.038ν + 0.005 N. In numerical simulations using a multiple mass tether model, tethers with lengths of several kilometers are deployed and the attitude dynamics of satellites attached to the end of the tether and tether libration are calculated. As a result, the simulations confirmed successful deployment of the tether with a length of 500 m using the electrodynamic tether system.

  17. Stratified polymer brushes from microcontact printing of polydopamine initiator on polymer brush surfaces.

    Science.gov (United States)

    Wei, Qiangbing; Yu, Bo; Wang, Xiaolong; Zhou, Feng

    2014-06-01

    Stratified polymer brushes are fabricated using microcontact printing (μCP) of initiator integrated polydopamine (PDOPBr) on polymer brush surfaces and the following surface initiated atom transfer radical polymerization (SI-ATRP). It is found that the surface energy, chemically active groups, and the antifouling ability of the polymer brushes affect transfer efficiency and adhesive stability of the polydopamine film. The stickiness of the PDOPBr pattern on polymer brush surfaces is stable enough to perform continuous μCP and SI-ATRP to prepare stratified polymer brushes with a 3D topography, which have broad applications in cell and protein patterning, biosensors, and hybrid surfaces. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Tethered Satellite System Contingency Investigation Board

    Science.gov (United States)

    1992-11-01

    The Tethered Satellite System (TSS-1) was launched aboard the Space Shuttle Atlantis (STS-46) on July 31, 1992. During the attempted on-orbit operations, the Tethered Satellite System failed to deploy successfully beyond 256 meters. The satellite was retrieved successfully and was returned on August 6, 1992. The National Aeronautics and Space Administration (NASA) Associate Administrator for Space Flight formed the Tethered Satellite System (TSS-1) Contingency Investigation Board on August 12, 1992. The TSS-1 Contingency Investigation Board was asked to review the anomalies which occurred, to determine the probable cause, and to recommend corrective measures to prevent recurrence. The board was supported by the TSS Systems Working group as identified in MSFC-TSS-11-90, 'Tethered Satellite System (TSS) Contingency Plan'. The board identified five anomalies for investigation: initial failure to retract the U2 umbilical; initial failure to flyaway; unplanned tether deployment stop at 179 meters; unplanned tether deployment stop at 256 meters; and failure to move tether in either direction at 224 meters. Initial observations of the returned flight hardware revealed evidence of mechanical interference by a bolt with the level wind mechanism travel as well as a helical shaped wrap of tether which indicated that the tether had been unwound from the reel beyond the travel by the level wind mechanism. Examination of the detailed mission events from flight data and mission logs related to the initial failure to flyaway and the failure to move in either direction at 224 meters, together with known preflight concerns regarding slack tether, focused the assessment of these anomalies on the upper tether control mechanism. After the second meeting, the board requested the working group to complete and validate a detailed integrated mission sequence to focus the fault tree analysis on a stuck U2 umbilical, level wind mechanical interference, and slack tether in upper tether

  19. ``Smart'' Surfaces of Polymer Brushes

    Science.gov (United States)

    Wang, Qiang; Meng, Dong

    2009-03-01

    ``Smart'' surfaces, also known as stimuli-responsive surfaces, can change their properties (e.g., wettability, adhesion, friction, elasticity, and biocompatibility) in response to external stimuli (e.g., temperature, pressure, light, solvent selectivity, ionic strength, type of salt, pH, applied electric field, etc.). In this work, we use numerical self-consistent field calculations to study in detail the structure and stimuli- responses of various polymer brushes, including (1) the thermo- response of PNIPAM brushes in water, (2) solvent-response of uncharged diblock copolymer brushes, and (3) the stimuli- response of charged two-component polymer brushes (including both the binary A/B brushes and diblock copolymer A-B brushes) to ionic strength, pH, and applied electric field. Among the many design parameters (e.g., chain lengths, grafting densities, A-B incompatibility, degree of ionization of charged polymers, etc.) we identify those that strongly affect the surface switchability. Such knowledge is useful to the experimental design of these smart polymer brushes for their applications.

  20. Space Station tethered elevator system

    Science.gov (United States)

    Haddock, Michael H.; Anderson, Loren A.; Hosterman, K.; Decresie, E.; Miranda, P.; Hamilton, R.

    1989-01-01

    The optimized conceptual engineering design of a space station tethered elevator is presented. The tethered elevator is an unmanned, mobile structure which operates on a ten-kilometer tether spanning the distance between Space Station Freedom and a platform. Its capabilities include providing access to residual gravity levels, remote servicing, and transportation to any point along a tether. The report discusses the potential uses, parameters, and evolution of the spacecraft design. Emphasis is placed on the elevator's structural configuration and three major subsystem designs. First, the design of elevator robotics used to aid in elevator operations and tethered experimentation is presented. Second, the design of drive mechanisms used to propel the vehicle is discussed. Third, the design of an onboard self-sufficient power generation and transmission system is addressed.

  1. Coat/Tether Interactions—Exception or Rule?

    Science.gov (United States)

    Schröter, Saskia; Beckmann, Sabrina; Schmitt, Hans Dieter

    2016-01-01

    Coat complexes are important for cargo selection and vesicle formation. Recent evidence suggests that they may also be involved in vesicle targeting. Tethering factors, which form an initial bridge between vesicles and the target membrane, may bind to coat complexes. In this review, we ask whether these coat/tether interactions share some common mechanisms, or whether they are special adaptations to the needs of very specific transport steps. We compare recent findings in two multisubunit tethering complexes, the Dsl1 complex and the HOPS complex, and put them into context with the TRAPP I complex as a prominent example for coat/tether interactions. We explore where coat/tether interactions are found, compare their function and structure, and comment on a possible evolution from a common ancestor of coats and tethers. PMID:27243008

  2. Coat/Tether Interactions-Exception or Rule?

    Science.gov (United States)

    Schroeter, Saskia; Beckmann, Sabrina; Schmitt, Hans Dieter

    2016-01-01

    Coat complexes are important for cargo selection and vesicle formation. Recent evidence suggests that they may also be involved in vesicle targeting. Tethering factors, which form an initial bridge between vesicles and the target membrane, may bind to coat complexes. In this review, we ask whether these coat/tether interactions share some common mechanisms, or whether they are special adaptations to the needs of very specific transport steps. We compare recent findings in two multisubunit tethering complexes, the Dsl1 complex and the HOPS complex, and put them into context with the TRAPP I complex as a prominent example for coat/tether interactions. We explore where coat/tether interactions are found, compare their function and structure, and comment on a possible evolution from a common ancestor of coats and tethers.

  3. Water Soluble Responsive Polymer Brushes

    Directory of Open Access Journals (Sweden)

    Andrew J. Parnell

    2011-12-01

    Full Text Available Responsive polymer brushes possess many interesting properties that enable them to control a range of important interfacial behaviours, including adhesion, wettability, surface adsorption, friction, flow and motility. The ability to design a macromolecular response to a wide variety of external stimuli makes polymer brushes an exciting class of functional materials, and has been made possible by advances in modern controlled polymerization techniques. In this review we discuss the physics of polymer brush response along with a summary of the techniques used in their synthesis. We then review the various stimuli that can be used to switch brush conformation; temperature, solvent quality, pH and ionic strength as well as the relatively new area of electric field actuation We discuss examples of devices that utilise brush conformational change, before highlighting other potential applications of responsive brushes in real world devices.

  4. Two Tethered Balloon Systems

    Science.gov (United States)

    Youngbluth, Otto; Owens, Thomas L.; Storey, Richard W.

    1990-01-01

    Systems take meteorological measurements for variety of research projects. Report describes work done by NASA Langley Research Center in atmospheric research using tethered balloon systems composed of commercially available equipment. Two separate tethered balloon systems described in report have payloads and configurations tailored to requirements of specific projects. Each system capable of measuring atmospheric parameter or species in situ and then telemetering this data in real time to ground station. Meteorological data and concentration of ozone typically measured. Indicates instrumented tethered balloon systems have distinct advantages over other systems for gathering data on troposphere.

  5. Brush head composition, wear profile, and cleaning efficacy: an assessment of three electric brush heads using in vitro methods.

    Science.gov (United States)

    Kaiser, Eva; Meyners, Michael; Markgraf, Dirk; Stoerkel, Ulrich; von Koppenfels, Roxana; Adam, Ralf; Soukup, Martin; Wehrbein, Heinrich; Erbe, Christina

    2014-01-01

    The objective of this research was to evaluate a current store brand (SB) brush head for composition/physical characteristics, Wear Index (WI), and cleaning efficacy versus the previous SB brush head refill design (SB control) and the Oral-B Precision Clean brush head (positive control, PC). This research consisted of three parts: 1) Analytical analysis using Fourier Transform Infrared (FT-IR) spectrometry to evaluate the chemical composition of the current SB brush head bristles relative to the SB control. In addition, physical parameters such as bristle count and diameter were determined. 2) Wear Index (WI) investigation to determine the Wear Index scores of in vitro-aged brush heads at four weeks (one month) and 13 weeks (three months) by a trained investigator. To "age" the brush heads, a robot system was used as a new alternative in vitro method to simulate aging by consumer use. 3) Robot testing to determine the cleaning performance of in vitro-aged brush heads, comparing one month-aged current SB brush heads with the SB control (one and three months-aged) and the PC brush heads (three months-aged) in a standardized fashion. 1) FT-IR analysis revealed that the chemical composition of the current and control SB refill brush heads is identical. In terms of physical parameters, the current SB brush head has 12% more bristles and a slightly oval brush head compared to the round brush head of the SB control. 2) Wear Index analysis showed there was no difference in the one month-aged current SB brush head versus the one month-aged SB control (1.67 vs. 1.50, p = 0.65) or versus the three months-aged PC brush head (1.67 vs. 1.50, p = 0.65). The one month-aged current SB brush head demonstrated statistically significantly less wear than the three months-aged SB control (1.67 vs. 2.67, p = 0.01). 3) Analysis of cleaning efficacy shows that the one month-aged current SB brush head had improved cleaning performance over the one month-aged SB control brush head (p < 0

  6. AFM-based force spectroscopy on polystyrene brushes: effect of brush thickness on protein adsorption.

    Science.gov (United States)

    Hentschel, Carsten; Wagner, Hendrik; Smiatek, Jens; Heuer, Andreas; Fuchs, Harald; Zhang, Xi; Studer, Armido; Chi, Lifeng

    2013-02-12

    Herein we present a study on nonspecific binding of proteins at highly dense packed hydrophobic polystyrene brushes. In this context, an atomic force microscopy tip was functionalized with concanavalin A to perform single-molecule force spectroscopy measurements on polystyrene brushes with thicknesses of 10 and 60 nm, respectively. Polystyrene brushes with thickness of 10 nm show an almost two times stronger protein adsorption than brushes with a thickness of 60 nm: 72 pN for the thinner and 38 pN for the thicker layer, which is in qualitative agreement with protein adsorption studies conducted macroscopically by fluorescence microscopy.

  7. Space tether dynamics: an introduction

    Science.gov (United States)

    Denny, Mark

    2018-05-01

    The dynamics of orbiting tethers (space elevators and skyhooks) is developed from an unusual direction: Lagrangian rather than Newtonian mechanics. These basic results are derived among others: space elevator required length with and without counterweight, location and magnitude of maximum tether tension, skyhook orbital parameters and tether tension. These conceptual devices are being increasingly discussed as technologically feasible; here they make an interesting pedagogical application of Lagrangian mechanics suitable for undergraduate physics students.

  8. The space station tethered elevator system

    Science.gov (United States)

    Anderson, Loren A.

    1989-01-01

    The optimized conceptual engineering design of a space station tethered elevator is presented. The elevator is an unmanned mobile structure which operates on a ten kilometer tether spanning the distance between the Space Station and a tethered platform. Elevator capabilities include providing access to residual gravity levels, remote servicing, and transportation to any point along a tether. The potential uses, parameters, and evolution of the spacecraft design are discussed. Engineering development of the tethered elevator is the result of work conducted in the following areas: structural configurations; robotics, drive mechanisms; and power generation and transmission systems. The structural configuration of the elevator is presented. The structure supports, houses, and protects all systems on board the elevator. The implementation of robotics on board the elevator is discussed. Elevator robotics allow for the deployment, retrieval, and manipulation of tethered objects. Robotic manipulators also aid in hooking the elevator on a tether. Critical to the operation of the tethered elevator is the design of its drive mechanisms, which are discussed. Two drivers, located internal to the elevator, propel the vehicle along a tether. These modular components consist of endless toothed belts, shunt-wound motors, regenerative power braking, and computer controlled linear actuators. The designs of self-sufficient power generation and transmission systems are reviewed. Thorough research indicates all components of the elevator will operate under power provided by fuel cells. The fuel cell systems will power the vehicle at seven kilowatts continuously and twelve kilowatts maximally. A set of secondary fuel cells provides redundancy in the unlikely event of a primary system failure. Power storage exists in the form of Nickel-Hydrogen batteries capable of powering the elevator under maximum loads.

  9. Coat/tether interactions – exceptions or rule?

    Directory of Open Access Journals (Sweden)

    Saskia eSchroeter

    2016-05-01

    Full Text Available Coat complexes are important for cargo selection and vesicle formation. Recent evidence suggests that they may also be involved in vesicle targeting. Tethering factors, which form an initial bridge between vesicles and the target membrane, may bind to coat complexes. In this review, we ask whether these coat/tether interactions share some common mechanisms, or whether they are special adaptations to the needs of very specific transport steps. We compare recent findings in two multisubunit tethering complexes, the Dsl1 complex and the HOPS complex, and put them into context with the TRAPP I complex as a prominent example for coat/tether interactions. We explore where coat/tether interactions are found, compare their function and structure, and comment on a possible evolution from a common ancestor of coats and tethers.

  10. Antifouling Properties of Fluoropolymer Brushes toward Organic Polymers: The Influence of Composition, Thickness, Brush Architecture, and Annealing.

    Science.gov (United States)

    Wang, Zhanhua; Zuilhof, Han

    2016-07-05

    Fluoropolymer brushes are widely used to prevent nonspecific adsorption of commercial polymeric or biological materials due to their strongly hydrophobic character. Herein, a series of fluoropolymer brushes with different compositions, thicknesses and molecular architectures was prepared via surface-initiated atom transfer radical polymerization (ATRP). Subsequently, the antifouling properties of these fluoropolymer brushes against organic polymers were studied in detail using X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) measurements and polystyrene as a representative fouling polymer. Among all of the molecular architectures studied, homopolymerized methacrylate-based fluoropolymer brushes (PMAF17) show the best antifouling properties. Annealing the fluoropolymer brushes improves the antifouling property dramatically due to the reregulated surface composition. These fluoropolymer brushes can be combined with, e.g., micro- and nanostructuring and other advanced materials properties to yield even better long-term antifouling behavior under harsh environments.

  11. Slow brushing reduces heat pain in humans.

    Science.gov (United States)

    Liljencrantz, J; Strigo, I; Ellingsen, D M; Krämer, H H; Lundblad, L C; Nagi, S S; Leknes, S; Olausson, H

    2017-08-01

    C-tactile (CT) afferents are unmyelinated low-threshold mechanoreceptors optimized for signalling affective, gentle touch. In three separate psychophysical experiments, we examined the contribution of CT afferents to pain modulation. In total, 44 healthy volunteers experienced heat pain and CT optimal (slow brushing) and CT sub-optimal (fast brushing or vibration) stimuli. Three different experimental paradigms were used: Concurrent application of heat pain and tactile (slow brushing or vibration) stimulation; Slow brushing, applied for variable duration and intervals, preceding heat pain; Slow versus fast brushing preceding heat pain. Slow brushing was effective in reducing pain, whereas fast brushing or vibration was not. The reduction in pain was significant not only when the CT optimal touch was applied simultaneously with the painful stimulus but also when the two stimuli were separated in time. For subsequent stimulation, the pain reduction was more pronounced for a shorter time interval between brushing and pain. Likewise, the effect was more robust when pain was preceded by a longer duration of brush stimulation. Strong CT-related pain reduction was associated with low anxiety and high calmness scores obtained by a state anxiety questionnaire. Slow brushing - optimal for CT activation - is effective in reducing pain from cutaneous heating. The precise mechanisms for the pain relief are as yet unknown but possible mechanisms include inhibition of nociceptive projection neurons at the level of the dorsal horn as well as analgesia through cortical mechanisms. Slow brushing stimuli - optimal for activation of C-tactile fibres - can reduce pain from cutaneous heating. No such effect was seen with fast brushing or vibration. These observations indicate the role of C-tactile fibres in pain modulation. © 2017 European Pain Federation - EFIC®.

  12. Tether Elevator Crawler Systems (TECS)

    Science.gov (United States)

    Swenson, Frank R.

    1987-01-01

    One of the needs of the experimenters on the space station is access to steady and controlled-variation microgravity environments. A method of providing these environments is to place the experiment on a tether attached to the space station. This provides a high degree of isolation from structural oscillations and vibrations. Crawlers can move these experiments along the tethers to preferred locations, much like an elevator. This report describes the motion control laws developed for these crawlers and the testing of laboratory models of these tether elevator crawlers.

  13. Novel pH- and temperature-responsive blend hydrogel microspheres of sodium alginate and PNIPAAm-g-GG for controlled release of isoniazid.

    Science.gov (United States)

    Kajjari, Praveen B; Manjeshwar, Lata S; Aminabhavi, Tejraj M

    2012-12-01

    This paper reports the preparation and characterization of novel pH- and thermo-responsive blend hydrogel microspheres of sodium alginate (NaAlg) and poly(N-isopropylacrylamide)(PNIPAAm)-grafted-guar gum (GG) i.e., PNIPAAm-g-GG by emulsion cross-linking method using glutaraldehyde (GA) as a cross-linker. Isoniazid (INZ) was chosen as the model antituberculosis drug to achieve encapsulation up to 62%. INZ has a plasma half-life of 1.5 h, whose release was extended up to 12 h. Fourier transform infrared spectroscopy was used to confirm the grafting reaction and chemical stability of INZ during the encapsulation. Differential scanning calorimetry was used to investigate the drug's physical state, while powder X-ray diffraction confirmed the molecular level dispersion of INZ in the matrix. Scanning electron microscopy confirmed varying surface morphologies of the drug-loaded microspheres. Temperature- and pH-responsive nature of the blend hydrogel microspheres were investigated by equilibrium swelling, and in vitro release experiments were performed in pH 1.2 and pH 7.4 buffer media at 37°C as well as at 25°C. Kinetics of INZ release was analyzed by Ritger-Peppas empirical equation to compute the diffusional exponent parameter (n), whose value ranged between 0.27 and 0.58, indicating the release of INZ follows a diffusion swelling controlled release mechanism.

  14. Molecular Structure of Membrane Tethers

    NARCIS (Netherlands)

    Baoukina, Svetlana; Marrink, Siewert J.; Tieleman, D. Peter

    2012-01-01

    Membrane tethers are nanotubes formed by a lipid bilayer. They play important functional roles in cell biology and provide an experimental window on lipid properties. Tethers have been studied extensively in experiments and described by theoretical models, but their molecular structure remains

  15. Space Environmental Effects on Coated Tether Materials

    Science.gov (United States)

    Gittemeier, Keith A.; Hawk, Clark W.; Finckenor, Miria M.; Watts, Ed

    2005-01-01

    The University of Alabama in Huntsville s Propulsion Research Center has teamed with NASA's Marshall Space Flight Center (MSFC) to research the effects of atomic oxygen (AO) bombardment on coated tether materials. Tethers Unlimited Inc. has provided several candidate tether materials with various coatings for AO exposure in MSFC s Atomic Oxygen Beam Facility. Additional samples were exposed to ultraviolet (UV) radiation at MSFC. AO erodes most organic materials, and ultraviolet radiation embrittles polymers. This test series was performed to determine the effect of AO and UV on the mechanical integrity of tether materials that were treated with AO-protective coatings, such as polyhedral oligomeric silsesquioxane (POSS) or metallization. Both TUI's Multi-Application Survivable Tether (MAST) Experiment and Marshall Space Flight Center s Momentum Exchange Electrodynamic Reboost (MXER) programs will benefit from this research by helping to determine tether materials and coatings that give the longest life with the lowest mass penalty.

  16. Membrane tethering complexes in the endosomal system

    Directory of Open Access Journals (Sweden)

    Anne eSpang

    2016-05-01

    Full Text Available Vesicles that are generated by endocytic events at the plasma membrane are destined to early endosomes. A prerequisite for proper fusion is the tethering of two membrane entities. Tethering of vesicles to early endosomes is mediated by the CORVET complex, while fusion of late endosomes with lysosomes depends on the HOPS complex. Recycling through the TGN and to the plasma membrane is facilitated by the GARP and EARP complexes, respectively. However, there are other tethering functions in the endosomal system as there are multiple pathways through which proteins can be delivered from endosomes to either the TGN or the plasma membrane. Furthermore, complexes that may be part of novel tethering complexes have been recently identified. Thus it is likely that more tethering factors exist. In this review, I will provide an overview of different tethering complexes of the endosomal system and discuss how they may provide specificity in membrane traffic.

  17. Stimuli-Responsive Polyelectrolyte Brushes As a Matrix for the Attachment of Gold Nanoparticles: The Effect of Brush Thickness on Particle Distribution

    Directory of Open Access Journals (Sweden)

    Stephanie Christau

    2014-06-01

    Full Text Available The effect of brush thickness on the loading of gold nanoparticles (AuNPs within stimuli-responsive poly-(N,N-(dimethylamino ethyl methacrylate (PDMAEMA polyelectrolyte brushes is reported. Atom transfer radical polymerization (ATRP was used to grow polymer brushes via a “grafting from” approach. The brush thickness was tuned by varying the polymerization time. Using a new type of sealed reactor, thick brushes were synthesized. A systematic study was performed by varying a single parameter (brush thickness, while keeping all other parameters constant. AuNPs of 13 nm in diameter were attached by incubation. X-ray reflectivity, electron scanning microscopy and ellipsometry were used to study the particle loading, particle distribution and interpenetration of the particles within the brush matrix. A model for the structure of the brush/particle hybrids was derived. The particle number densities of attached AuNPs depend on the brush thickness, as do the optical properties of the hybrids. An increasing particle number density was found for increasing brush thickness, due to an increased surface roughness.

  18. Attitude control analysis of tethered de-orbiting

    Science.gov (United States)

    Peters, T. V.; Briz Valero, José Francisco; Escorial Olmos, Diego; Lappas, V.; Jakowski, P.; Gray, I.; Tsourdos, A.; Schaub, H.; Biesbroek, R.

    2018-05-01

    The increase of satellites and rocket upper stages in low earth orbit (LEO) has also increased substantially the danger of collisions in space. Studies have shown that the problem will continue to grow unless a number of debris are removed every year. A typical active debris removal (ADR) mission scenario includes launching an active spacecraft (chaser) which will rendezvous with the inactive target (debris), capture the debris and eventually deorbit both satellites. Many concepts for the capture of the debris while keeping a connection via a tether, between the target and chaser have been investigated, including harpoons, nets, grapples and robotic arms. The paper provides an analysis on the attitude control behaviour for a tethered de-orbiting mission based on the ESA e.Deorbit reference mission, where Envisat is the debris target to be captured by a chaser using a net which is connected to the chaser with a tether. The paper provides novel insight on the feasibility of tethered de-orbiting for the various mission phases such as stabilization after capture, de-orbit burn (plus stabilization), stabilization during atmospheric pass, highlighting the importance of various critical mission parameters such as the tether material. It is shown that the selection of the appropriate tether material while using simple controllers can reduce the effort needed for tethered deorbiting and can safely control the attitude of the debris/chaser connected with a tether, without the danger of a collision.

  19. Tethering factors as organizers of intracellular vesicular traffic.

    Science.gov (United States)

    Yu, I-Mei; Hughson, Frederick M

    2010-01-01

    Intracellular trafficking entails the budding, transport, tethering, and fusion of transport vesicles and other membrane carriers. Here we review recent progress toward a mechanistic understanding of vesicle tethering. The known tethering factors are large complexes important for one or more intracellular trafficking pathways and are capable of interacting directly with many of the other principal components of the cellular trafficking machinery. Our review emphasizes recent developments in the in vitro reconstitution of vesicle tethering and the structural characterization of multisubunit tethering factors. The combination of these and other approaches has led to exciting progress toward understanding how these essential nanomachines work.

  20. Atmospheric Electricity and Tethered Aerostats, Volume 1

    Science.gov (United States)

    1976-05-11

    CATALOG NUMBER AFETR -TR-76-07 __ 4. TITLE (and Subtitle) -. TYPE OF REPORT & PERIOD COVERED ATMOSPHERIC ELECTRICITY AND TETHERED AEROSTATS, FINAL. 1...Electricity Faraday Capes Balloons Lightning Effects , Protection, Warning Systems Conducting and Non-Conducting ’Tethers Potential Geadient Anomalies...and identifying feasible protective systems. After a brief introductory section math models of effects of tethered balloons on surrounding

  1. Tether Deployer And Brake

    Science.gov (United States)

    Carroll, Joseph A.; Alexander, Charles M.

    1993-01-01

    Design concept promises speed, control, and reliability. Scheme for deploying tether provides for fast, free, and snagless payout and fast, dependable braking. Developed for small, expendable tethers in outer space, scheme also useful in laying transoceanic cables, deploying guidance wires to torpedoes and missiles, paying out rescue lines from ship to ship via rockets, deploying antenna wires, releasing communication and power cables to sonobuoys and expendable bathythermographs, and in reeling out lines from fishing rods.

  2. Review of deployment technology for tethered satellite systems

    Science.gov (United States)

    Yu, B. S.; Wen, H.; Jin, D. P.

    2018-03-01

    Tethered satellite systems (TSSs) have attracted significant attention due to their potential and valuable applications for scientific research. With the development of various launched on-orbit missions, the deployment of tethers is considered a crucial technology for operation of a TSS. Both past orbiting experiments and numerical results have shown that oscillations of the deployed tether due to the Coriolis force and environmental perturbations are inevitable and that the impact between the space tether and end-body at the end of the deployment process leads to complicated nonlinear phenomena. Hence, a set of suitable control methods plays a fundamental role in tether deployment. This review article summarizes previous work on aspects of the dynamics, control, and ground-based experiments of tether deployment. The relevant basic principles, analytical expressions, simulation cases, and experimental results are presented as well.

  3. Dynamic multibody modeling for tethered space elevators

    Science.gov (United States)

    Williams, Paul

    2009-08-01

    This paper presents a fundamental modeling strategy for dealing with powered and propelled bodies moving along space tethers. The tether is divided into a large number of discrete masses, which are connected by viscoelastic springs. The tether is subject to the full range of forces expected in Earth orbit in a relatively simple manner. Two different models of the elevator dynamics are presented. In order to capture the effect of the elevator moving along the tether, the elevator dynamics are included as a separate body in both models. One model treats the elevator's motion dynamically, where propulsive and friction forces are applied to the elevator body. The second model treats the elevator's motion kinematically, where the distance along the tether is determined by adjusting the lengths of tether on either side of the elevator. The tether model is used to determine optimal configurations for the space elevator. A modal analysis of two different configurations is presented which show that the fundamental mode of oscillation is a pendular one around the anchor point with a period on the order of 160 h for the in-plane motion, and 24 h for the out-of-plane motion. Numerical simulation results of the effects of the elevator moving along the cable are presented for different travel velocities and different elevator masses.

  4. Atmospheric Electricity and Tethered Aerostats, Volume 2

    Science.gov (United States)

    1976-05-11

    EASTERN TEST RANGE PATRICK AIR FORCE BASE, FLORIDA 11 MAY 1976 028 099 AFETR -TR-76-07 ATMOSPHERIC ELECTRICITY AND ~TETHERED AEROSTATS, VOLUME 11 Range...number) Atmospheric Electricity Lightning- Effects , Protection, Warning Balloons Systems Conducting & Nonconducting Tethers Potential Gradient Anomalies...if necessary and Identify by block number) Part A, "Atmospheric Electrical Effects of and on Tethered Balloon Systems," by Latham includes airborne

  5. Anthrax Cases Associated with Animal-Hair Shaving Brushes.

    Science.gov (United States)

    Szablewski, Christine M; Hendricks, Kate; Bower, William A; Shadomy, Sean V; Hupert, Nathaniel

    2017-05-01

    During the First World War, anthrax cases in the United States and England increased greatly and seemed to be associated with use of new shaving brushes. Further investigation revealed that the source material and origin of shaving brushes had changed during the war. Cheap brushes of imported horsehair were being made to look like the preferred badger-hair brushes. Unfortunately, some of these brushes were not effectively disinfected and brought with them a nasty stowaway: Bacillus anthracis. A review of outbreak summaries, surveillance data, and case reports indicated that these cases originated from the use of ineffectively disinfected animal-hair shaving brushes. This historical information is relevant to current public health practice because renewed interest in vintage and animal-hair shaving brushes has been seen in popular culture. This information should help healthcare providers and public health officials answer questions on this topic.

  6. Interaction between two polyelectrolyte brushes.

    Science.gov (United States)

    Kumar, N Arun; Seidel, Christian

    2007-08-01

    We report molecular dynamics simulations on completely charged polyelectrolyte brushes grafted to two parallel surfaces. The pressure Pi is evaluated as a function of separation D between the two grafting planes. For decreasing separation, Pi shows several regimes distinguished by their scaling with D which reflects the different physical nature of the various regimes. At weak compression the pressure obeys the 1D power law predicted by scaling theory of an ideal gas of counterions in the osmotic brush regime. In addition we find that the brushes shrink as they approach each other trying to avoid interpenetration. At higher compressions where excluded volume interactions become important, we obtain scaling exponents between -2 at small grafting density rho(a) and -3 at large rho(a). This behavior indicates a transition from a brush under good solvent condition to the melt regime with increasing grafting density.

  7. A randomized clinical trial evaluating gingivitis and plaque reduction of an oscillating-rotating power brush with a new brush head with angled bristles versus a marketed sonic brush with self-adjusting technology.

    Science.gov (United States)

    Klukowska, Malgorzata; Grender, Julie M; Conde, Erinn; Ccahuana-Vasquez, Renzo Alberto; Ram Goyal, C

    2014-08-01

    To compare the efficacy of an oscillating-rotating power toothbrush with a novel brush head incorporating angled CrissCross bristles (Oral-B Pro 7000 SmartSeries and Oral-B CrossAction brush head) versus a marketed sonic toothbrush (Colgate ProClinical A1500 with the Triple Clean brush head) in the reduction of gingivitis and plaque over a 6-week period. This was a single center, randomized, open label, examiner-blind, 2-treatment, parallel group study. Study participants who met the entrance criteria were enrolled in the study and randomly assigned to one of the two toothbrush groups. Study participants brushed with their assigned toothbrush and a marketed fluoride dentifrice for 2 minutes twice daily at home for 6 weeks. Gingivitis and plaque were evaluated at baseline and Week 6. Gingivitis was assessed using the Modified Gingival Index (MGI) and Gingival Bleeding Index (GBI) and plaque was assessed using the Rustogi Modified Navy Plaque Index (RMNPI). Data was analyzed using the ANCOVA with baseline as the covariate. In total, 130 study participants were randomized to treatment resulting in 64 study participants per group completing the study. Both brushes produced statistically significant (P gingivitis and plaque measures relative to baseline. The oscillating-rotating,brush with the novel brush head demonstrated statistically significantly (P gingivitis measures, as well as whole mouth and interproximal plaque measures, compared to the sonic toothbrush. The benefit for the oscillating- rotating brush over the sonic brush was 21.3% for gingivitis, 35.7% for gingival bleeding, 34.7% for number of bleeding sites, 17.4% for whole mouth plaque, and 21.2% for interproximal plaque. There were no adverse events reported or observed for either brush.

  8. GRASP: A multitasking tether

    Directory of Open Access Journals (Sweden)

    Catherine eRabouille

    2016-01-01

    Full Text Available Originally identified as Golgi stacking factors in vitro, the Golgi reassembly stacking protein (GRASP family has been shown to act as membrane tethers with multiple cellular roles. As an update to previous comprehensive reviews of the GRASP family (Vinke et al., 2011 (Giuliani et al., 2011;Jarvela and Linstedt, 2012, we outline here the latest findings concerning their diverse roles. New insights into the mechanics of GRASP-mediated tethering come from recent crystal structures. The models of how GRASP65 and GRASP55 tether membranes relate directly to their role in Golgi ribbon formation in mammalian cells and the unlinking of the ribbon at the onset of mitosis. However, it is also clear that GRASPs act outside the Golgi with roles at the ER and ER exit sites (ERES. Furthermore, the proteins of this family display other roles upon cellular stress, especially in mediating unconventional secretion of both transmembrane proteins (Golgi bypass and cytoplasmic proteins (through secretory autophagosomes.

  9. Nanopatterned polymer brushes: conformation, fabrication and applications

    Science.gov (United States)

    Yu, Qian; Ista, Linnea K.; Gu, Renpeng; Zauscher, Stefan; López, Gabriel P.

    2015-12-01

    Surfaces with end-grafted, nanopatterned polymer brushes that exhibit well-defined feature dimensions and controlled chemical and physical properties provide versatile platforms not only for investigation of nanoscale phenomena at biointerfaces, but also for the development of advanced devices relevant to biotechnology and electronics applications. In this review, we first give a brief introduction of scaling behavior of nanopatterned polymer brushes and then summarize recent progress in fabrication and application of nanopatterned polymer brushes. Specifically, we highlight applications of nanopatterned stimuli-responsive polymer brushes in the areas of biomedicine and biotechnology.

  10. Passivity-Based Control of a Rigid Electrodynamic Tether

    DEFF Research Database (Denmark)

    Larsen, Martin Birkelund; Blanke, Mogens

    2011-01-01

    Electrodynamic tethers provide actuation for performing orbit correction of spacecrafts. When an electrodynamic tether system is orbiting the Earth in an inclined orbit, periodic changes in the magnetic field result in a family of unstable periodic solutions in the attitude motion. This paper shows...... how these periodic solutions can be stabilized by controlling only the current through the tether. A port-controlled Hamiltonian formulation is employed to describe the tethered satellite system and a passive input-output connection is utilized in the control design. The control law consists of two...

  11. Assessing tether anchor labeling and usability in pickup trucks.

    Science.gov (United States)

    Klinich, Kathleen D; Manary, Miriam A; Malik, Laura A; Flannagan, Carol A; Jermakian, Jessica S

    2018-04-03

    The objective of this study was to investigate vehicle factors associated with child restraint tether use and misuse in pickup trucks and evaluate 4 labeling interventions designed to educate consumers on proper tether use. Volunteer testing was performed with 24 subjects and 4 different pickup trucks. Each subject performed 8 child restraint installations among the 4 pickups using 2 forward-facing restraints: a Britax Marathon G4.1 and an Evenflo Triumph. Vehicles were selected to represent 4 different implementations of tether anchors among pickups: plastic loop routers (Chevrolet Silverado), webbing routers (Ram), back wall anchors (Nissan Frontier), and webbing routers plus metal anchors (Toyota Tundra). Interventions included a diagram label, Quick Response (QR) Code linked to video instruction, coordinating text label, and contrasting text tag. Subjects used the child restraint tether in 93% of trials. However, tether use was completely correct in only 9% of trials. An installation was considered functional if the subject attached the tether to a tether anchor and had a tight installation (ignoring routing and head restraint position); 28% of subjects achieved a functional installation. The most common installation error was attaching the tether hook to the anchor/router directly behind the child restraint (near the top of the seatback) rather than placing the tether through the router and attaching it to the anchor in the adjacent seating position. The Nissan Frontier, with the anchor located on the back wall of the cab, had the highest rate of correct installations but also had the highest rate of attaching the tether to components other than the tether anchor (seat adjustor, child restraint storage hook, around head restraint). None of the labeling interventions had a significant effect on correct installation; not a single subject scanned the QR Code to access the video instruction. Subjects with the most successful installations spent extensive time

  12. Nonlinearity in the rotational dynamics of Haidinger's brushes

    Science.gov (United States)

    Rothmayer, Mark; Dultz, Wolfgang; Frins, Erna; Zhan, Qiwen; Tierney, Dennis; Schmitzer, Heidrun

    2007-10-01

    Haidinger's brushes are an entoptic effect of the human visual system that enables us to detect polarized light. However, individual perceptions of Haidinger's brushes can vary significantly. We find that the birefringence of the cornea influences the rotational motion and the contrast of Haidinger's brushes and may offer an explanation for individual differences. We have devised an experimental setup to simulate various phase shifts of the cornea and found a switching effect in the rotational dynamics of Haidinger's brushes. In addition, age related macular degeneration reduces the polarization effect of the macula and thus also leads to changes in the brush pattern.

  13. Mobile tethering: Overview, perspectives and challengess

    NARCIS (Netherlands)

    Constantinescu, M.; Onur, E.; Durmus, Y.; Nikou, S.; Reuver, M. de; Bouwman, H.; Djurica, M.; Glatz, P.M.

    2014-01-01

    Purpose: The purpose of this paper is to analyze mobile tethering from technological and social perspectives. Mobile tethering allows us to share cellular data connection with others over WiFi, Bluetooth or USB. Although the technology is ready and has promising outcomes, service providers and the

  14. Membrane Tethering Complexes in the Endosomal System

    OpenAIRE

    Spang, Anne

    2016-01-01

    Vesicles that are generated by endocytic events at the plasma membrane are destined to early endosomes. A prerequisite for proper fusion is the tethering of two membrane entities. Tethering of vesicles to early endosomes is mediated by the class C core vacuole/endosome tethering (CORVET) complex, while fusion of late endosomes with lysosomes depends on the homotypic fusion and vacuole protein sorting (HOPS) complex. Recycling through the trans-Golgi network (TGN) and to the plasma membrane is...

  15. Enabling Tethered Exploration on Mars, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Strong science motivations exist for exploring hard to reach terrain on Mars and the leading systems proposed to do so require tethers. While tethers are used...

  16. Tether applications for space station

    Science.gov (United States)

    Nobles, W.

    1986-01-01

    A wide variety of space station applications for tethers were reviewed. Many will affect the operation of the station itself while others are in the category of research or scientific platforms. One of the most expensive aspects of operating the space station will be the continuing shuttle traffic to transport logistic supplies and payloads to the space station. If a means can be found to use tethers to improve the efficiency of that transportation operation, it will increase the operating efficiency of the system and reduce the overall cost of the space station. The concept studied consists of using a tether to lower the shuttle from the space station. This results in a transfer of angular momentum and energy from the orbiter to the space station. The consequences of this transfer is studied and how beneficial use can be made of it.

  17. Polyelectrolyte brushes at the air/water interface

    International Nuclear Information System (INIS)

    Matsuoka, Hideki

    2005-01-01

    The nanostructure of amphiphilic diblock copolymer monolayer on water surface was investigated by in situ X-ray and neutron reflectivity. The diblock copolymers used have a long hydrophobic chain and a polyelectrolyte chain as a hydrophilic block. The monolayer was found not to have a simple double layer structure (hydrophobic layer / hydrophilic (carpet) layer) but to have a three layer structure consisting of hydrophobic layer, hydrophilic dense carpet layer, and polyelectrolyte brush layer when the polyelectrolyte block is long enough and the surface pressure (i.e. brush density) is high enough. The transition from carpet only to carpet/brush double layer structure in hydrophilic layer was observed as a function of polyelectrolyte chain length, the surface pressure. When the hydrophilic chain is a weak polyelectrolyte, the monolayer first expanded and then shrunk with increasing salt concentration in the subphase. For the strongly ionic polyelectrolyte, the monolayer structure was not affected by salt addition up to ∼0.2 M. These observations can be explained by a balance of the charged state of the brush chain, an electrostatic repulsion between brush chains and salt concentration in the brush layer

  18. Investigation of electrodynamic stabilization and control of long orbiting tethers

    Science.gov (United States)

    Colombo, G.; Arnold, D.

    1984-01-01

    The state-of-the-art in tether modelling among participants in the Tethered Satellite System (TSS) Program, the slack tether and its behavior, and certain advanced applications of the tether to problems in orbital mechanics are identified. The features and applications of the TSS software set are reviewed. Modelling the slack tether analytically with as many as 50 mass points and the application of this new model to a study of the behavior of a broken tether near the Shuttle are described. A reel control algorithm developed by SAO and examples of its use are described, including an example which also demonstrates the use of the tether in transferring a heavy payload from a low-orbiting Shuttle to a high circular orbit. Capture of a low-orbiting payload by a Space Station in high circular orbit is described. Energy transfer within a dumbbell-type spacecraft by cyclical reeling operations or gravitational effects on the natural elasticity of the connecting tether, it is shown, can circularize the orbit of the spacecraft.

  19. Flowing Plasma Interaction with an Electric Sail Tether Element

    Science.gov (United States)

    Schneider, Todd; Vaughn, Jason; Wright, Kenneth; Anderson, Allen; Stone, Nobie

    2017-01-01

    Harnessing the power of the solar wind, an Electric Sail, or E-sail, is a relatively new concept that promises to deliver high speed propellant-less propulsion. The electric sail is an invention made in 2006 at the Kumpula Space Centre in Finland by Pekka Janhunen [Janhunen and Sandroos, 2007]. At its core, an electric sail utilizes multiple positively biased tethers which exchange momentum with solar wind protons via the repelling electric field established around each tether, in other words, by reflecting the solar wind protons. Recognizing the solar wind is a plasma, the effective repelling area of each tether is increased significantly by the formation a plasma sheath around each tether. Fig. 1 shows schematically a spacecraft employing an electric sail. The positive voltage bias (greater than10kV) applied to each tether naturally results in electron collection. Therefore, the electric sail concept necessarily includes an electron source (electron gun) to return collected electrons to space and maintain the positive bias of the tether system.

  20. Modeling and Simulation of a Tethered Harpoon for Comet Sampling

    Science.gov (United States)

    Quadrelli, Marco B.

    2014-01-01

    This paper describes the development of a dynamic model and simulation results of a tethered harpoon for comet sampling. This model and simulation was done in order to carry out an initial sensitivity analysis for key design parameters of the tethered system. The harpoon would contain a canister which would collect a sample of soil from a cometary surface. Both a spring ejected canister and a tethered canister are considered. To arrive in close proximity of the spacecraft at the end of its trajectory so it could be captured, the free-flying canister would need to be ejected at the right time and with the proper impulse, while the tethered canister must be recovered by properly retrieving the tether at a rate that would avoid an excessive amplitude of oscillatory behavior during the retrieval. The paper describes the model of the tether dynamics and harpoon penetration physics. The simulations indicate that, without the tether, the canister would still reach the spacecraft for collection, that the tether retrieval of the canister would be achievable with reasonable fuel consumption, and that the canister amplitude upon retrieval would be insensitive to variations in vertical velocity dispersion.

  1. Water driven turbine/brush pipe cleaner

    Science.gov (United States)

    Werlink, Rudy J. (Inventor)

    1995-01-01

    Assemblies are disclosed for cleaning the inside walls of pipes and tubes. A first embodiment includes a small turbine with angled blades axially mounted on one end of a standoff support. An O-ring for stabilizing the assembly within the pipe is mounted in a groove within the outer ring. A replaceable circular brush is fixedly mounted on the opposite end of the standoff support and can be used for cleaning tubes and pipes of various diameters, lengths and configurations. The turbine, standoff support, and brush spin in unison relative to a hub bearing that is fixedly attached to a wire upstream of the assembly. The nonrotating wire is for retaining the assembly in tension and enabling return of the assembly to the pipe entrance. The assembly is initially placed in the pipe or tube to be cleaned. A pressurized water or solution source is provided at a required flow-rate to propel the assembly through the pipe or tube. The upstream water pressure propels and spins the turbine, standoff support and brush. The rotating brush combined with the solution cleans the inside of the pipe. The solution flows out of the other end of the pipe with the brush rotation controlled by the flow-rate. A second embodiment is similar to the first embodiment but instead includes a circular shaped brush with ring backing mounted in the groove of the exterior ring of the turbine, and also reduces the size of the standoff support or eliminates the standoff support.

  2. Dual wound dc brush motor gearhead

    Science.gov (United States)

    Henson, Barrie W.

    1986-01-01

    The design requirements, the design, development tests and problems, the qualification and life test and the findings of the strip examination of a dual wound DC brushed motor gearhead are described. It is the only space qualified dual wound dc brushed motor gearhead in Europe.

  3. Binary Polymer Brushes of Strongly Immiscible Polymers.

    Science.gov (United States)

    Chu, Elza; Babar, Tashnia; Bruist, Michael F; Sidorenko, Alexander

    2015-06-17

    The phenomenon of microphase separation is an example of self-assembly in soft matter and has been observed in block copolymers (BCPs) and similar materials (i.e., supramolecular assemblies (SMAs) and homo/block copolymer blends (HBCs)). In this study, we use microphase separation to construct responsive polymer brushes that collapse to generate periodic surfaces. This is achieved by a chemical reaction between the minor block (10%, poly(4-vinylpyridine)) of the block copolymer and a substrate. The major block of polystyrene (PS) forms mosaic-like arrays of grafted patches that are 10-20 nm in size. Depending on the nature of the assembly (SMA, HBC, or neat BCP) and annealing method (exposure to vapors of different solvents or heating above the glass transition temperature), a range of "mosaic" brushes with different parameters can be obtained. Successive grafting of a secondary polymer (polyacrylamide, PAAm) results in the fabrication of binary polymer brushes (BPBs). Upon being exposed to specific selective solvents, BPBs may adopt different conformations. The surface tension and adhesion of the binary brush are governed by the polymer occupying the top stratum. The "mosaic" brush approach allows for a combination of strongly immiscible polymers in one brush. This facilitates substantial contrast in the surface properties upon switching, previously only possible for substrates composed of predetermined nanostructures. We also demonstrate a possible application of such PS/PAAm brushes in a tunable bioadhesion-bioadhesive (PS on top) or nonbioadhesive (PAAm on top) surface as revealed by Escherichia coli bacterial seeding.

  4. Brush seal performance measurement system

    OpenAIRE

    Aksoy, Serdar; Akşit, Mahmut Faruk; Aksit, Mahmut Faruk; Duran, Ertuğrul Tolga; Duran, Ertugrul Tolga

    2009-01-01

    Brush seals are rapidly replacing conventional labyrinth seals in turbomachinery applications. Upon pressure application, seal stiffness increases drastically due to frictional bristle interlocking. Operating stiffness is critical to determine seal wear life. Typically, seal stiffness is measured by pressing a curved shoe to brush bore. The static-unpressurized measurement is extrapolated to pressurized and high speed operating conditions. This work presents a seal stiffness measurement syste...

  5. Tension waves in tethered satellite cables

    Science.gov (United States)

    Lallman, F. J.

    1984-01-01

    A one-degree-of-freedom simulation of the Tethered Satellite System (TSS) was programmed using a distributed system model of the tether based on the one-dimensional wave equation. This model represents the time varying tension profile along the tether as the sum of two traveling waves of tension moving in opposite directions. A control loop was devised which combines a deployment rate command with the measured tension at the deployer to produce a smooth, stable rate of deployment of the subsatellite. Simulation results show a buildup of periodic bursts of high frequency oscillation in tension. This report covers the mathematical modelling and simulation results and explains the reason for the observed oscillations. The design of a possible vibration damping device is discussed.

  6. The stochastic dynamics of tethered microcantilevers in a viscous fluid

    Energy Technology Data Exchange (ETDEWEB)

    Robbins, Brian A.; Paul, Mark R. [Department of Mechanical Engineering, Virginia Tech, Blacksburg, Virginia 24061 (United States); Radiom, Milad; Ducker, William A. [Department of Chemical Engineering, Virginia Tech, Blacksburg, Virginia 24061 (United States); Walz, John Y. [Department of Chemical Engineering, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2014-10-28

    We explore and quantify the coupled dynamics of a pair of micron scale cantilevers immersed in a viscous fluid that are also directly tethered to one another at their tips by a spring force. The spring force, for example, could represent the molecular stiffness or elasticity of a biomolecule or material tethered between the cantilevers. We use deterministic numerical simulations with the fluctuation-dissipation theorem to compute the stochastic dynamics of the cantilever pair for the conditions of experiment when driven only by Brownian motion. We validate our approach by comparing directly with experimental measurements in the absence of the tether which shows excellent agreement. Using numerical simulations, we quantify the correlated dynamics of the cantilever pair over a range of tether stiffness. Our results quantify the sensitivity of the auto- and cross-correlations of equilibrium fluctuations in cantilever displacement to the stiffness of the tether. We show that the tether affects the magnitude of the correlations which can be used in a measurement to probe the properties of an attached tethering substance. For the configurations of current interest using micron scale cantilevers in water, we show that the magnitude of the fluid coupling between the cantilevers is sufficiently small such that the influence of the tether can be significant. Our results show that the cross-correlation is more sensitive to tether stiffness than the auto-correlation indicating that a two-cantilever measurement has improved sensitivity when compared with a measurement using a single cantilever.

  7. Models of dynamic extraction of lipid tethers from cell membranes

    International Nuclear Information System (INIS)

    Nowak, Sarah A; Chou, Tom

    2010-01-01

    When a ligand that is bound to an integral membrane receptor is pulled, the membrane and the underlying cytoskeleton can deform before either the membrane delaminates from the cytoskeleton or the ligand detaches from the receptor. If the membrane delaminates from the cytoskeleton, it may be further extruded and form a membrane tether. We develop a phenomenological model for this process by assuming that deformations obey Hooke's law up to a critical force at which the cell membrane locally detaches from the cytoskeleton and a membrane tether forms. We compute the probability of tether formation and show that tethers can be extruded only within an intermediate range of force loading rates and pulling velocities. The mean tether length that arises at the moment of ligand detachment is computed as are the force loading rates and pulling velocities that yield the longest tethers

  8. Lyapunov Orbits in the Jupiter System Using Electrodynamic Tethers

    Science.gov (United States)

    Bokelmann, Kevin; Russell, Ryan P.; Lantoine, Gregory

    2013-01-01

    Various researchers have proposed the use of electrodynamic tethers for power generation and capture from interplanetary transfers. The effect of tether forces on periodic orbits in Jupiter-satellite systems are investigated. A perturbation force is added to the restricted three-body problem model and a series of simplifications allows development of a conservative system that retains the Jacobi integral. Expressions are developed to find modified locations of equilibrium positions. Modified families of Lyapunov orbits are generated as functions of tether size and Jacobi integral. Zero velocity curves and stability analyses are used to evaluate the dynamical properties of tether-modified orbits.

  9. Magnetohydrodynamic instability of a cylindrical liquid-metal brush

    International Nuclear Information System (INIS)

    Hong, S.H.; Wilhelm, H.E.

    1976-01-01

    The stability of a homopolar generator brush, consisting of a liquid-metal-filled cavity between rotating (rotor) and fixed (stator) cylinder electrodes, is analyzed in the presence of radial current transport and an axial homogeneous magnetic field. Within the frame of linear magnetohydrodynamics, it is shown that the liquid-metal flow in the brush is always unstable if the brush transports current. In the absence of current flow (infinite load) the axial magnetic field stabilizes the liquid-metal flow in the brush if the magnetic energy density is larger than a certain fraction of the energy density of the rotating fluid

  10. Contaminated tooth brushes-potential threat to oral and general health

    Directory of Open Access Journals (Sweden)

    Rashmi Naik

    2015-01-01

    Full Text Available Background: Tooth brushing is most common method of maintaining oral hygiene. In removing plaque and other soft debris from the teeth, tooth brushes become contaminated with bacteria, blood, saliva and oral debris. These contaminated tooth brushes can be a source of infection. Aims and objectives: The aim of the present study was to evaluate the presence of microorganisms in the tooth brushes and to investigate the effect of disinfectants such as chlorhexidine gluconate, sodium hypochlorite and water to decontaminate them. Materials and Methods: Twenty-one children were asked to brush their teeth for 5 days with a tooth brush. The tooth brushes were put in Robertson′s Cooked Meat broth and were observed for growth of Streptococcal microorganisms. These tooth brushes were then placed in disinfectants such as 0.2% chlorhexidine gluconate (Group I, 1% sodium hypochlorite (Group II and water (Group III for 24 hrs and then cultured again. Reduction of growth of microorganisms was seen in Group I, Group II and remnants of growth seen in Group III. Conclusion: We conclude that the use of disinfectant for a tooth brush is a must for every individual at least at regular intervals.

  11. The PROPEL Electrodynamic Tether Demonstration Mission

    Science.gov (United States)

    Bilen, Sven G.; Johnson, C. Les; Wiegmann, Bruce M.; Alexander, Leslie; Gilchrist, Brian E.; Hoyt, Robert P.; Elder, Craig H.; Fuhrhop, Keith P.; Scadera, Michael

    2012-01-01

    The PROPEL ("Propulsion using Electrodynamics") mission will demonstrate the operation of an electrodynamic tether propulsion system in low Earth orbit and advance its technology readiness level for multiple applications. The PROPEL mission has two primary objectives: first, to demonstrate the capability of electrodynamic tether technology to provide robust and safe, near-propellantless propulsion for orbit-raising, de-orbit, plane change, and station keeping, as well as to perform orbital power harvesting and formation flight; and, second, to fully characterize and validate the performance of an integrated electrodynamic tether propulsion system, qualifying it for infusion into future multiple satellite platforms and missions with minimal modification. This paper provides an overview of the PROPEL system and design reference missions; mission goals and required measurements; and ongoing PROPEL mission design efforts.

  12. Superhydrophilic Polyelectrolyte Brush Layers with Imparted Anti-Icing Properties

    DEFF Research Database (Denmark)

    Chernyy, Sergey; Järn, Mikael; Shimizu, Kyoko

    2014-01-01

    . In general, superhydrophilic polyelectrolyte brushes exhibit better anti-icing property at -10 °C compared to partially hydrophobic brushes such as poly(methyl methacrylate) and surfactant exchanged polyelectrolyte brushes. The data are interpreted using the concept of a quasi liquid layer (QLL...

  13. Use of top tethers with forward-facing child restraints: observations and driver interviews.

    Science.gov (United States)

    Eichelberger, Angela H; Decina, Lawrence E; Jermakian, Jessica S; McCartt, Anne T

    2014-02-01

    Despite the safety benefits, many parents do not use top tethers with forward-facing child restraints. Detailed information was collected about why parents are not using tethers. The sample included 479 drivers who had forward-facing child restraints installed in passenger vehicles equipped with tether anchors. The survey was conducted primarily at shopping centers, recreation facilities, child care facilities, car seat check events, and health care facilities in mostly suburban areas surrounding Philadelphia, Washington, DC, Fredericksburg (VA), and Seattle. Drivers were surveyed about their knowledge and use of tethers and experience with child restraints. Tether use was observed to verify whether tethers were being used correctly. Fifty-six percent of forward-facing child restraints were installed with the tether; 39% were installed with the tether used correctly. The tether was used with 71% of LATCH lower anchor installations and 33% of seat belt installations. Drivers who installed child restraints without tethers most often said they did not know about the tether or how to use it. Although the tether use rate was slightly higher in the current research than in previous studies, many parents and caregivers still use forward-facing child restraints without attaching the tether. Because the main problem is lack of awareness of the tether or how to use it, public education should focus specifically on the safety benefits of tethers and how to use them. Information about why caregivers fail to use top tethers is potentially useful to child restraint manufacturers, child passenger safety technicians, and others who work with parents to improve motor vehicle safety. Copyright © 2013 Elsevier Ltd and National Safety Council. All rights reserved.

  14. Numerical modelling of elastic space tethers

    DEFF Research Database (Denmark)

    Kristiansen, Kristian Uldall; Palmer, P. L.; Roberts, R. M.

    2012-01-01

    In this paper the importance of the ill-posedness of the classical, non-dissipative massive tether model on an orbiting tether system is studied numerically. The computations document that via the regularisation of bending resistance a more reliable numerical integrator can be produced. Furthermo....... It is also shown that on the slow manifold the dynamics of the satellites are well-approximated by the finite dimensional slack-spring model....

  15. Virtual hairy brush for digital painting and calligraphy

    Institute of Scientific and Technical Information of China (English)

    XU Songhua; Lau Francis C. M.; XU Congfu; PAN Yunhe

    2005-01-01

    The design of user friendly and expressive virtual brush systems for interactive digital painting and calligraphy has attracted a lot of attention and effort in both computer graphics and human-computer interaction circles for a long time. Providing a digital environment for paper-less artwork creation is not only challenging in terms of algorithmic design, but also promising for its potential market values. This paper proposes a novel algorithmic framework for interactive digital painting and calligraphy based a novel virtual hairy brush model. The algorithms in the kernel of our simulation framework are built upon solid modeling techniques. Implementing the algorithms, we have developed a virtual hairy brush prototype system with which end users can interactively produce high-quality digital paintings and calligraphic artwork. (The latest progress of our virtual brush project is reported at the website "http://www.cs.hku.hk/~songhua/e-brush/".)

  16. Method for making a high current fiber brush collector

    Science.gov (United States)

    Scuro, S. J.

    1986-05-01

    An axial-type homopolar motor having high density, high current fiber brush collectors affording efficient, low contact resistance and low operating temperatures is discussed. The collectors include a ring of concentric row of brushes in equally spaced beveled holes soldered in place using a fixture for heating the ring to just below the solder melting point at a soldering iron for the local application of additional heat at each brush. Prior to soldering, an oxide film is formed on the surfaces of the brushes and ring, and the bevels are burnished to form a wetting surface. Flux applied with the solder at each bevel removes to an effective soldering depth the oxide film on the brushes and the holes.

  17. Cold plasma brush generated at atmospheric pressure

    International Nuclear Information System (INIS)

    Duan Yixiang; Huang, C.; Yu, Q. S.

    2007-01-01

    A cold plasma brush is generated at atmospheric pressure with low power consumption in the level of several watts (as low as 4 W) up to tens of watts (up to 45 W). The plasma can be ignited and sustained in both continuous and pulsed modes with different plasma gases such as argon or helium, but argon was selected as a primary gas for use in this work. The brush-shaped plasma is formed and extended outside of the discharge chamber with typical dimension of 10-15 mm in width and less than 1.0 mm in thickness, which are adjustable by changing the discharge chamber design and operating conditions. The brush-shaped plasma provides some unique features and distinct nonequilibrium plasma characteristics. Temperature measurements using a thermocouple thermometer showed that the gas phase temperatures of the plasma brush are close to room temperature (as low as 42 deg. C) when running with a relatively high gas flow rate of about 3500 ml/min. For an argon plasma brush, the operating voltage from less than 500 V to about 2500 V was tested, with an argon gas flow rate varied from less than 1000 to 3500 ml/min. The cold plasma brush can most efficiently use the discharge power as well as the plasma gas for material and surface treatment. The very low power consumption of such an atmospheric argon plasma brush provides many unique advantages in practical applications including battery-powered operation and use in large-scale applications. Several polymer film samples were tested for surface treatment with the newly developed device, and successful changes of the wettability property from hydrophobic to hydrophilic were achieved within a few seconds

  18. Modeling and Control of Electrodynamic Tethers - an Energy and Topology Approach

    DEFF Research Database (Denmark)

    Larsen, Martin Birkelund

    A space tether is a cable used to connect spacecrafts in an orbiting structure. If an electrical current is lead through the tether, it can be utilized to provide propulsion for the spacecraft. In this case the cable is referred to as an electrodynamic tether. The system utilizes the magnetic field...... of the Earth for creating a Lorentz force along the tether which occur when a current carrying wire operates in a magnetic field. The use of electrodynamic tethers are interesting since they operate solely on electrical energy, which can be provided by solar panels of the spacecrafts. In this way the amount...... when using electrodynamic tethers is that the force created along the tether is based on an external uncontrollable condition, namely the magnetic field. Even whit a known model of the magnetic field, limitations to the creation of the Lorentz force still exists, since the force can only be generated...

  19. Polyelectrolyte brushes: a novel stable lubrication system in aqueous conditions.

    Science.gov (United States)

    Kobayashi, Motoyasu; Terada, Masami; Takahara, Atsushi

    2012-01-01

    Surface-initiated controlled radical copolymerizations of 2-dimethylaminoethyl methacrylate (DMAEMA), 2-(methacryloyloxy)ethyl phosphorylcholine (MPC), 2-(methacryloyloxy)ethyltrimethylammonium chloride) (MTAC), and 3-sulfopropyl methacrylate potassium salt (SPMK) were carried out on a silicon wafer and glass ball to prepare polyelectrolyte brushes with excellent water wettability. The frictional coefficient of the polymer brushes was recorded on a ball-on-plate type tribometer by linear reciprocating motion of the brush specimen at a selected velocity of 1.5 x 10(-3) m s-1 under a normal load of 0.49 N applied to the stationary glass ball (d = 10 mm) at 298 K. The poly(DMAEMA-co-MPC) brush partially cross-linked by bis(2-iodoethoxy)ethane maintained a relatively low friction coefficient around 0.13 under humid air (RH > 75%) even after 200 friction cycles. The poly(SPMK) brush revealed an extremely low friction coefficient around 0.01 even after 450 friction cycles. We supposed that the abrasion of the brush was prevented owing to the good affinity of the poly(SPMK) brush for water forming a water lubrication layer, and electrostatic repulsive interactions among the brushes bearing sulfonic acid groups. Furthermore, the poly(SPMK-co-MTAC) brush with a chemically cross-linked structure showed a stable low friction coefficient in water even after 1400 friction cycles under a normal load of 139 MPa, indicating that the cross-linking structure improved the wear resistance of the brush layer.

  20. One kilometer (1 km) electric solar wind sail tether produced automatically.

    Science.gov (United States)

    Seppänen, Henri; Rauhala, Timo; Kiprich, Sergiy; Ukkonen, Jukka; Simonsson, Martin; Kurppa, Risto; Janhunen, Pekka; Hæggström, Edward

    2013-09-01

    We produced a 1 km continuous piece of multifilament electric solar wind sail tether of μm-diameter aluminum wires using a custom made automatic tether factory. The tether comprising 90,704 bonds between 25 and 50 μm diameter wires is reeled onto a metal reel. The total mass of 1 km tether is 10 g. We reached a production rate of 70 m/24 h and a quality level of 1‰ loose bonds and 2‰ rebonded ones. We thus demonstrated that production of long electric solar wind sail tethers is possible and practical.

  1. Evaluation of multi-brush anode systems in microbial fuel cells

    KAUST Repository

    Lanas, Vanessa

    2013-11-01

    The packing density of anodes in microbial fuel cells (MFCs) was examined here using four different graphite fiber brush anode configurations. The impact of anodes on performance was studied in terms of carbon fiber length (brush diameter), the number of brushes connected in parallel, and the wire current collector gage. MFCs with different numbers of brushes (one, three or six) set perpendicular to the cathode all produced similar power densities (1200±40mW/m2) and coulombic efficiencies (60%±5%). Reducing the number of brushes by either disconnecting or removing them reduced power, demonstrating the importance of anode projected area covering the cathode, and therefore the need to match electrode projected areas to maintain high performance. Multi-brush reactors had the same COD removal as single-brush systems (90%). The use of smaller Ti wire gages did not affect power generation, which will enable the use of less metal, reducing material costs. © 2013 Elsevier Ltd.

  2. Selected Tether Applications Cost Model

    Science.gov (United States)

    Keeley, Michael G.

    1988-01-01

    Diverse cost-estimating techniques and data combined into single program. Selected Tether Applications Cost Model (STACOM 1.0) is interactive accounting software tool providing means for combining several independent cost-estimating programs into fully-integrated mathematical model capable of assessing costs, analyzing benefits, providing file-handling utilities, and putting out information in text and graphical forms to screen, printer, or plotter. Program based on Lotus 1-2-3, version 2.0. Developed to provide clear, concise traceability and visibility into methodology and rationale for estimating costs and benefits of operations of Space Station tether deployer system.

  3. TMBM: Tethered Micro-Balloons on Mars

    Science.gov (United States)

    Sims, M. H.; Greeley, R.; Cutts, J. A.; Yavrouian, A. H.; Murbach, M.

    2000-01-01

    The use of balloons/aerobots on Mars has been under consideration for many years. Concepts include deployment during entry into the atmosphere from a carrier spacecraft, deployment from a lander, use of super-pressurized systems for long duration flights, 'hot-air' systems, etc. Principal advantages include the ability to obtain high-resolution data of the surface because balloons provide a low-altitude platform which moves relatively slowly. Work conducted within the last few years has removed many of the technical difficulties encountered in deployment and operation of balloons/aerobots on Mars. The concept proposed here (a tethered balloon released from a lander) uses a relatively simple approach which would enable aspects of Martian balloons to be tested while providing useful and potentially unique science results. Tethered Micro-Balloons on Mars (TMBM) would be carried to Mars on board a future lander as a stand-alone experiment having a total mass of one to two kilograms. It would consist of a helium balloon of up to 50 cubic meters that is inflated after landing and initially tethered to the lander. Its primary instrumentation would be a camera that would be carried to an altitude of up to tens of meters above the surface. Imaging data would be transmitted to the lander for inclusion in the mission data stream. The tether would be released in stages allowing different resolutions and coverage. In addition during this staged release a lander camera system may observe the motion of the balloon at various heights above he lander. Under some scenarios upon completion of the primary phase of TMBM operations, the tether would be cut, allowing TMBM to drift away from the landing site, during which images would be taken along the ground.

  4. Analytical investigation of the dynamics of tethered constellations in Earth orbit, phase 2

    Science.gov (United States)

    Lorenzini, Enrico C.; Gullahorn, Gordon E.; Cosmo, Mario L.; Estes, Robert D.; Grossi, Mario D.

    1994-01-01

    This final report covers nine years of research on future tether applications and on the actual flights of the Small Expendable Deployment System (SEDS). Topics covered include: (1) a description of numerical codes used to simulate the orbital and attitude dynamics of tethered systems during station keeping and deployment maneuvers; (2) a comparison of various tethered system simulators; (3) dynamics analysis, conceptual design, potential applications and propagation of disturbances and isolation from noise of a variable gravity/microgravity laboratory tethered to the Space Station; (4) stability of a tethered space centrifuge; (5) various proposed two-dimensional tethered structures for low Earth orbit for use as planar array antennas; (6) tethered high gain antennas; (7) numerical calculation of the electromagnetic wave field on the Earth's surface on an electrodynamically tethered satellite; (8) reentry of tethered capsules; (9) deployment dynamics of SEDS-1; (10) analysis of SEDS-1 flight data; and (11) dynamics and control of SEDS-2.

  5. 75 FR 13489 - Natural Bristle Paint Brushes and Brush Heads from the People's Republic of China: Final Results...

    Science.gov (United States)

    2010-03-22

    ... Brushes and Brush Heads from the People's Republic of China: Final Results of the Expedited Sunset Review... from the People's Republic of China (``PRC'') pursuant to section 751(c) of the Tariff Act of 1930, as amended (``the Act''). See Initiation of Five-year (``Sunset'') Review, 74 FR 56593 (November 2, 2009...

  6. Tooth brushing among 11- to 15-year-olds in Denmark

    DEFF Research Database (Denmark)

    Bast, L. S.; Holstein, B. E.; Nordahl, Helene

    2015-01-01

    brushing. Results: 10,607 respondents: a response rate of 88.3%. Boys of lower social class had higher odds ratio (OR) of infrequent tooth brushing than girls: 1.98 (95% confidence interval 1.62-2.41) vs 1.80 (1.53-2.24). Immigrants and descendants had higher odds compared to adolescents of Danish origin......Objective: Regular tooth brushing in adolescence predicts stable tooth brushing habits later in life. Differences in tooth brushing habits by ethnic background and socioeconomic position have been suggested. We investigated migration status and social class in relation to infrequent tooth brushing...... both separately and combined. Methods: The study population was 11-15 year-olds chosen from a clustered random sample of schools. Univariate and multivariate logistic regression analyses estimated the separate and combined effects of migration status and social class on less than twice daily tooth...

  7. The Science and Applications Tethered Platform (SATP) project

    Science.gov (United States)

    Merlina, P.

    1986-01-01

    The capabilities of tether systems in orbit are going to be demonstrated by the first planned flights of the Tethered Satellite System (TSS). These test flights will investigate the properties of tether systems as low altitude atmospheric research facilities and as electric power generators. Studies are being conducted with the purpose of testing a variety of concepts and approaches. A comparative analysis of results will allow the choosing of the most promising ideas for further development. The broad range of applications presently under study include applications in electrodynamics, transportation, microgravity in addition to basic research. The SATP project definition study is now about midway through its first phase. The analyses conducted have led to an appraisal of users interest in the project and to a deeper understanding of the problems associated with large, long-lived tether systems in space. In addition, two specialized platform designs, devoted to microgravity and precise pointing applications, are being studied because of their potential usefulness and the promise of technical feasibility.

  8. Clinical evaluation of a newly designed orthodontic tooth brush - A clinical study

    Directory of Open Access Journals (Sweden)

    C S Saimbi

    2009-01-01

    In this study, the newly designed orthodontic tooth brush is compared with an ordinary tooth brush. Results of this study show that the newly designed orthodontic tooth brush is superior in its cleaning efficiency as compared to the ordinary tooth brush. The results show that plaque removing capacity of orthodontic tooth brush is nearly 95-99%.

  9. Endobiliary brush biopsy

    DEFF Research Database (Denmark)

    Adamsen, Sven; Olsen, Marianne; Jendresen, Marianne Bille

    2006-01-01

    OBJECTIVE: Obtaining cytological specimens by wire-guided endobiliary brushing at the time of endoscopic retrograde cholangiopancreatography (ERCP) is a convenient way to reach a diagnosis. Sensitivity for malignant disease is generally around 50% and specificity around 100%. The present study wa...

  10. Relaxation Dynamics of Nanoparticle-Tethered Polymer Chains

    KAUST Repository

    Kim, Sung A

    2015-09-08

    © 2015 American Chemical Society. Relaxation dynamics of nanoparticle-tethered cis-1,4-polyisoprene (PI) are investigated using dielectric spectroscopy and rheometry. A model system composed of polymer chains densely grafted to spherical SiO2 nanoparticles to form self-suspended suspensions facilitates detailed studies of slow global chain and fast segmental mode dynamics under surface and geometrical confinement-from experiments performed in bulk materials. We report that unentangled polymer molecules tethered to nanoparticles relax far more slowly than their tethered entangled counterparts. Specifically, at fixed grafting density we find, counterintuitively, that increasing the tethered polymer molecular weight up to values close to the entanglement molecular weight speeds up chain relaxation dynamics. Decreasing the polymer grafting density for a fixed molecular weight has the opposite effect: it dramatically slows down chain relaxation, increases interchain coupling, and leads to a transition in rheological response from simple fluid behavior to viscoelastic fluid behavior for tethered PI chains that are unentangled by conventional measures. Increasing the measurement temperature produces an even stronger elastic response and speeds up molecular relaxation at a rate that decreases with grafting density and molecular weight. These observations are discussed in terms of chain confinement driven by crowding between particles and by the existence of an entropic attractive force produced by the space-filling constraint on individual chains in a self-suspended material. Our results indicate that the entropic force between densely grafted polymer molecules couples motions of individual chains in an analogous manner to reversible cross-links in associating polymers.

  11. Temperature-responsive chromatography for the separation of biomolecules.

    Science.gov (United States)

    Kanazawa, Hideko; Okano, Teruo

    2011-12-09

    Temperature-responsive chromatography for the separation of biomolecules utilizing poly(N-isopropylacrylamide) (PNIPAAm) and its copolymer-modified stationary phase is performed with an aqueous mobile phase without using organic solvent. The surface properties and function of the stationary phase are controlled by external temperature changes without changing the mobile-phase composition. This analytical system is based on nonspecific adsorption by the reversible transition of a hydrophilic-hydrophobic PNIPAAm-grafted surface. The driving force for retention is hydrophobic interaction between the solute molecules and the hydrophobized polymer chains on the stationary phase surface. The separation of the biomolecules, such as nucleotides and proteins was achieved by a dual temperature- and pH-responsive chromatography system. The electrostatic and hydrophobic interactions could be modulated simultaneously with the temperature in an aqueous mobile phase, thus the separation system would have potential applications in the separation of biomolecules. Additionally, chromatographic matrices prepared by a surface-initiated atom transfer radical polymerization (ATRP) exhibit a strong interaction with analytes, because the polymerization procedure forms a densely packed polymer, called a polymer brush, on the surfaces. The copolymer brush grafted surfaces prepared by ATRP was an effective tool for separating basic biomolecules by modulating the electrostatic and hydrophobic interactions. Applications of thermally responsive columns for the separations of biomolecules are reviewed here. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Climber Motion Optimization for the Tethered Space Elevator

    NARCIS (Netherlands)

    Williams, P.; Ockels, W.J.

    The tethered space elevator could provide a revolutionary means for enabling cheap transportation to geostationary altitude and beyond. Assuming that such a system can be built, one of the dynamic design problems is determining a means of moving the elevator along the tether so as to minimize the

  13. IPN hydrogels based on PNIPAAm and PVA-Ma networks: characterization through measure of LCST, swelling ratio and mechanical properties - doi: 10.4025/actascitechnol.v34i2.15019

    OpenAIRE

    Wenceslau, Adriana Cristina; Universidade Estadual de Maringá - UEM; Rubira, Adley Forti; Universidade Estadual de Maringá - UEM; Muniz, Edvani Curti; UEM, Maringá, Paraná

    2011-01-01

    IPN hydrogels based on chemically modified poly(vinyl alcohol) (or PVA-Ma), with different degrees of substitution (DS), and poly(N-isopropylacrylamide) (or PNIPAAm) were obtained and characterized through measures of LCST, swelling ratio and mechanical properties. Linear PVA-Ma with several DS were obtained through the chemical reaction of PVA with glycidyl methacrylate (GMA). The DS of various PVA-Ma were determined through 1H NMR spectroscopy. Two steps were used for preparation the PVA-Ma...

  14. The effects of tether placement on antibody stability on surfaces

    Science.gov (United States)

    Grawe, Rebecca W.; Knotts, Thomas A.

    2017-06-01

    Despite their potential benefits, antibody microarrays have fallen short of performing reliably and have not found widespread use outside of the research setting. Experimental techniques have been unable to determine what is occurring on the surface of an atomic level, so molecular simulation has emerged as the primary method of investigating protein/surface interactions. Simulations of small proteins have indicated that the stability of the protein is a function of the residue on the protein where a tether is placed. The purpose of this research is to see whether these findings also apply to antibodies, with their greater size and complexity. To determine this, 24 tethering locations were selected on the antibody Protein Data Bank (PDB) ID: 1IGT. Replica exchange simulations were run on two different surfaces, one hydrophobic and one hydrophilic, to determine the degree to which these tethering sites stabilize or destabilize the antibody. Results showed that antibodies tethered to hydrophobic surfaces were in general less stable than antibodies tethered to hydrophilic surfaces. Moreover, the stability of the antibody was a function of the tether location on hydrophobic surfaces but not hydrophilic surfaces.

  15. Electroosmotic Flow in Mixed Polymer Brush-Grafted Nanochannels

    Directory of Open Access Journals (Sweden)

    Qianqian Cao

    2016-12-01

    Full Text Available Mixed polymer brush-grafted nanochannels—where two distinct species of polymers are alternately grafted on the inner surface of nanochannels—are an interesting class of nanostructured hybrid materials. By using a coarse-grained molecular dynamics simulation method, we are able to simulate the electrokinetic transport dynamics of the fluid in such nanochannels as well as the conformational behaviors of the mixed polymer brush. We find that (1 the brush adopts vertically-layered and longitudinally-separated structures due to the coupling of electroosmotic flow (EOF and applied electric field; (2 the solvent quality affects the brush conformations and the transport properties of the EOF; (3 the EOF flux non-monotonically depends on the grafting density, although the EOF velocity in the central region of the channel monotonically depends on the grafting density.

  16. Behavioral Determinants of Brushing Young Children's Teeth: Implications for Anticipatory Guidance

    Science.gov (United States)

    Huebner, Colleen E.; Riedy, Christine A.

    2010-01-01

    Purpose The purposes of this study were to identify parents' motivation, support, and barriers to twice daily tooth-brushing of infants and preschool-age children and to discover new approaches to encourage this important health behavior. Methods Qualitative interviews were conducted with 44 rural parents about tooth-brushing habits and experiences. Results Forty of 44 parents reported that they had begun to brush their child's teeth; 24 (55%) reported brushing twice a day or more. Parents who brushed twice a day, vs less often, were more likely to describe specific skills to overcome barriers; they expressed high self-efficacy and held high self-standards for brushing. Parents who brushed their children's teeth less than twice daily were more likely to: hold false beliefs about the benefits of twice daily tooth-brushing; report little normative pressure or social support for the behavior; have lower self-standards; describe more external constraints; and offer fewer ideas to overcome barriers. Conclusions The findings support an integrative framework in which barriers and support for parents' twice daily brushing of their young children's teeth are multiple and vary among individuals. Knowledge of behavioral determinants specific to individual parents could strengthen anticipatory guidance and recommendations about at-home oral hygiene of young children. PMID:20298653

  17. Surface grafted polymer brushes: potential applications in dengue biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Baratela, Fernando Jose Costa; Higa, Olga Zazuco, E-mail: ozahiga@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Faria, Henrique Antonio Mendonca de; Queiroz, Alvaro Antonio Alencar de, E-mail: alencar@unifei.edu.br [Universidade Federal de Itajuba (UNIFEI), Itajuba, MG (Brazil). Instituto de Fisica e Quimica

    2013-07-01

    A polymer brush membrane-based ultrasensitive biosensor for dengue diagnosis was constructed using poly(hydroxyethyl methacrylate) (PHEMA) brushes immobilized onto low density polyethylene (LDPE) films. LDPE surface films were initially modified by Ar{sup +} ion irradiation to activate the polymer surface. Subsequently, graft polymerization of 2-hydroxyethyl methacrylate onto the activated LDPE surface was carried out under aqueous conditions to create patterned polymer brushes of PHEMA. The grafted PHEMA brushes were characterized by Fourier transform-infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and contact angle analysis. The SEM observations showed that selective surface activation with Ar+ implantation and graft polymerization on the selectively activated surface had occurred. The PHEMA brushes were electrically characterized in the presence of concentrations of human immunoglobulin (IgG). The proposed amperometric biosensor was successfully used for determination of IgG in physiologic samples with excellent responses. (author)

  18. Surface grafted polymer brushes: potential applications in dengue biosensors

    International Nuclear Information System (INIS)

    Baratela, Fernando Jose Costa; Higa, Olga Zazuco; Faria, Henrique Antonio Mendonca de; Queiroz, Alvaro Antonio Alencar de

    2013-01-01

    A polymer brush membrane-based ultrasensitive biosensor for dengue diagnosis was constructed using poly(hydroxyethyl methacrylate) (PHEMA) brushes immobilized onto low density polyethylene (LDPE) films. LDPE surface films were initially modified by Ar + ion irradiation to activate the polymer surface. Subsequently, graft polymerization of 2-hydroxyethyl methacrylate onto the activated LDPE surface was carried out under aqueous conditions to create patterned polymer brushes of PHEMA. The grafted PHEMA brushes were characterized by Fourier transform-infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and contact angle analysis. The SEM observations showed that selective surface activation with Ar+ implantation and graft polymerization on the selectively activated surface had occurred. The PHEMA brushes were electrically characterized in the presence of concentrations of human immunoglobulin (IgG). The proposed amperometric biosensor was successfully used for determination of IgG in physiologic samples with excellent responses. (author)

  19. Efficiency of the surgical washing of hands with brush and without brush

    Directory of Open Access Journals (Sweden)

    Fresia Canales Carmona

    2013-10-01

    Full Text Available The purpose of this article is to establish the answer to a clinical question regarding the effectiveness ofpreoperative hygiene with hand washing brush or without it. This first technique has been performed on the skinto reduce transient bacteria and to inhibit the growth of resident microorganisms as a common and required actbefore any surgical procedure. Despite this measure and others such as prophylactic antibiotics, the mainoperative complication continues to be the surgical wound infection. Today, it is as prevalent as in the past withthe consequent negative effects derived from it, both for the institutions and for patients. Being controversialtoday which one is the most effective and safe surgical hand washing method for the binomial: professionalsurgical team/ patient, this study is done under the criteria of the Evidence-Based Nursing.A question was builtin PICO format (Personal, Intervention, Comparison and Outcome. After this is done, continues informationsearch in the databases GOOGLE ACADÉMICO, Pub Med, Cochrane y Base de Datos para la Investigación enEnfermería (BDIE We obtained 20 articles related to the topic of them 8, which fulfilled the set CASPe criteriato answer the clinical question, were analyzed. We conclude that washing hands with a brush is equally effectiveas without brush technique in terms of decreased of the superficial skin bacterial flora, although this technique hasadvantages over the traditional practice.

  20. Tethered Pyrotechnic Apparatus for Acquiring a Ground Sample

    Science.gov (United States)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq; Badescu, Mircea; Sherrit, Stewart

    2009-01-01

    A proposed alternative design for the balloon-borne ground-sampling system described in the immediately preceding article would not rely on free fall to drive a harpoonlike sample-collecting device into the ground. Instead, the harpoon-like sample-collecting device would be a pyrotechnically driven, tethered projectile. The apparatus would include a tripod that would be tethered to the gondola. A gun for shooting the projectile into the ground would be mounted at the apex of the tripod. The gun would include an electronic trigger circuit, a chamber at the breech end containing a pyrotechnic charge, and a barrel. A sabot would be placed in the barrel just below the pyrotechnic charge, and the tethered projectile would be placed in the barrel just below the sabot. The tripod feet would be equipped with contact sensors connected to the trigger circuit. In operation, the tripod would be lowered to the ground on its tether. Once contact with the ground was detected by the sensors on all three tripod feet, the trigger circuit would fire the pyrotechnic charge to drive the projectile into the ground. (Requiring contact among all three tripod feet and the ground would ensure that the projectile would be fired into the ground, rather than up toward the gondola or the balloon.) The tethered projectile would then be reeled back up to the gondola for analysis of the sample.

  1. Polymer Brushes: Synthesis, Characterization, Applications

    Science.gov (United States)

    Advincula, Rigoberto C.; Brittain, William J.; Caster, Kenneth C.; Rühe, Jürgen

    2004-09-01

    Materials scientists, polymer chemists, surface physicists and materials engineers will find this book a complete and detailed treatise on the field of polymer brushes, their synthesis, characterization and manifold applications. In a first section, the various synthetic pathways and different surface materials are introduced and explained, followed by a second section covering important aspects of characterization and analysis in both flat surfaces and particles. These specific surface initiated polymerization (SIP) systems such as linear polymers, homopolymers, block copolymers, and hyperbranched polymers are unique compared to previously reported systems by chemisorption or physisorption. They have found their way in both large-scale and miniature applications of polymer brushes, which is covered in the last section. Such 'hairy' surfaces offer fascinating opportunities for addressing numerous problems of both academic and, in particular, industrial interest: high-quality, functional or protective coatings, composite materials, surface engineered particles, metal-organic interfaces, biological applications, micro-patterning, colloids, nanoparticles, functional devices, and many more. It is the desire of the authors that this book will be of benefit to readers who want to "brush-up on polymers".

  2. Antifouling Properties of Fluoropolymer Brushes toward Organic Polymers

    NARCIS (Netherlands)

    Wang, Zhanhua; Zuilhof, Han

    2016-01-01

    Fluoropolymer brushes are widely used to prevent nonspecific adsorption of commercial polymeric or biological materials due to their strongly hydrophobic character. Herein, a series of fluoropolymer brushes with different compositions, thicknesses and molecular architectures was prepared via

  3. Fluid-membrane tethers: minimal surfaces and elastic boundary layers.

    Science.gov (United States)

    Powers, Thomas R; Huber, Greg; Goldstein, Raymond E

    2002-04-01

    Thin cylindrical tethers are common lipid bilayer membrane structures, arising in situations ranging from micromanipulation experiments on artificial vesicles to the dynamic structure of the Golgi apparatus. We study the shape and formation of a tether in terms of the classical soap-film problem, which is applied to the case of a membrane disk under tension subject to a point force. A tether forms from the elastic boundary layer near the point of application of the force, for sufficiently large displacement. Analytic results for various aspects of the membrane shape are given.

  4. Autonomous Vision-Based Tethered-Assisted Rover Docking

    Science.gov (United States)

    Tsai, Dorian; Nesnas, Issa A.D.; Zarzhitsky, Dimitri

    2013-01-01

    Many intriguing science discoveries on planetary surfaces, such as the seasonal flows on crater walls and skylight entrances to lava tubes, are at sites that are currently inaccessible to state-of-the-art rovers. The in situ exploration of such sites is likely to require a tethered platform both for mechanical support and for providing power and communication. Mother/daughter architectures have been investigated where a mother deploys a tethered daughter into extreme terrains. Deploying and retracting a tethered daughter requires undocking and re-docking of the daughter to the mother, with the latter being the challenging part. In this paper, we describe a vision-based tether-assisted algorithm for the autonomous re-docking of a daughter to its mother following an extreme terrain excursion. The algorithm uses fiducials mounted on the mother to improve the reliability and accuracy of estimating the pose of the mother relative to the daughter. The tether that is anchored by the mother helps the docking process and increases the system's tolerance to pose uncertainties by mechanically aligning the mating parts in the final docking phase. A preliminary version of the algorithm was developed and field-tested on the Axel rover in the JPL Mars Yard. The algorithm achieved an 80% success rate in 40 experiments in both firm and loose soils and starting from up to 6 m away at up to 40 deg radial angle and 20 deg relative heading. The algorithm does not rely on an initial estimate of the relative pose. The preliminary results are promising and help retire the risk associated with the autonomous docking process enabling consideration in future martian and lunar missions.

  5. Dynamics and stability of a tethered centrifuge in low earth orbit

    Science.gov (United States)

    Quadrelli, B. M.; Lorenzini, E. C.

    1992-01-01

    The three-dimensional attitude dynamics of a spaceborne tethered centrifuge for artificial gravity experiments in low earth orbit is analyzed using two different methods. First, the tethered centrifuge is modeled as a dumbbell with a straight viscoelastic tether, point tip-masses, and sophisticated environmental models such as nonspherical gravity, thermal perturbations, and a dynamic atmospheric model. The motion of the centrifuge during spin-up, de-spin, and steady-rotation is then simulated. Second, a continuum model of the tether is developed for analyzing the stability of lateral tether oscillations. Results indicate that the maximum fluctuation about the 1-g radial acceleration level is less than 0.001 g; the time required for spin-up and de-spin is less than one orbit; and lateral oscillations are stable for any practical values of the system parameters.

  6. Brushes and soap : grafted polymers and their interactions with nanocolloids

    NARCIS (Netherlands)

    Currie, E.P.K.

    2000-01-01

    Layers of polymer chains end-attached to a grafting plane at high densities, so-called brushes, are a curious state of matter. The (average) monomer density within the brush is as high as in a semi-dilute polymer solution, resulting in a high osmotic pressure in the brush. Due to the

  7. T-Rex: A Japanese Space Tether Experiment

    Science.gov (United States)

    Johnson, Les

    2009-01-01

    Electrodynamic tether (EDT) thrusters work by virtue of the force a magnetic field exerts on a wire carrying an electrical current. The force, which acts on any charged particle moving through a magnetic field (including the electrons moving in a current-carrying wire), were concisely expressed by Lorentz in 1895 in an equation that now bears his name. The force acts in a direction perpendicular to both the direction of current flow and the magnetic field vector. Electric motors make use of this force: a wire loop in a magnetic field is made to rotate by the torque the Lorentz Force exerts on it due to an alternating current in the loop times so as to keep the torque acting in the same sense. The motion of the loop is transmitted to a shaft, thus providing work. Although the working principle of EDT thrusters is not new, its application to space transportation may be significant. In essence, an EDT thruster is just a clever way of getting an electrical current to flow in a long orbiting wire (the tether) so that the Earth s magnetic field will accelerate the wire and, consequently the payload attached to the wire. The direction of current flow in the tether, either toward or away from the Earth along the local vertical, determines whether the magnetic force will raise or lower the orbit. The bias voltage of a vertically deployed metal tether, which results just from its orbital motion (assumed eastward) through Earth s magnetic field, is positive with respect to the ambient plasma at the top and negative at the bottom. This polarization is due to the action of the Lorentz force on the electrons in the tether. Thus, the natural current flow is the result of negative electrons being attracted to the upper end and then returned to the plasma at the lower end. The magnetic force in this case has a component opposite to the direction of motion, and thus leads to a lowering of the orbit and eventually to re-entry. In this generator mode of operation the Lorentz Force

  8. LM2500+ Brush Seal Case Study

    Science.gov (United States)

    Haaser, Fred G.

    2006-01-01

    The LM2500+ industrial aeroderivative gas turbine, a 25% enhanced power derivative of the LM2500 gas turbine, recently completed its development test program during the period 5/96 - 10/96. Early in the engine program a Quality Function Deployment (QFD) process was used to determine customer needs for this project.The feedback obtained from the QFD process showed without doubt that gas turbine customers now emphasize product reliability and availability at the top of their needs. One area of development on the LM2500+ was to investigate the use of a brush seal as a means to reduce undesirable turbine cooling leakages within the turbine mid frame in order to enhance part life. This presentation presents a case study on the factors that went into evaluating a brush seal during engine test, test results, and the ultimate decision not to implement the brush seal for cost and other reasons.

  9. Tethered Forth system for FPGA applications

    Science.gov (United States)

    Goździkowski, Paweł; Zabołotny, Wojciech M.

    2013-10-01

    This paper presents the tethered Forth system dedicated for testing and debugging of FPGA based electronic systems. Use of the Forth language allows to interactively develop and run complex testing or debugging routines. The solution is based on a small, 16-bit soft core CPU, used to implement the Forth Virtual Machine. Thanks to the use of the tethered Forth model it is possible to minimize usage of the internal RAM memory in the FPGA. The function of the intelligent terminal, which is an essential part of the tethered Forth system, may be fulfilled by the standard PC computer or by the smartphone. System is implemented in Python (the software for intelligent terminal), and in VHDL (the IP core for FPGA), so it can be easily ported to different hardware platforms. The connection between the terminal and FPGA may be established and disconnected many times without disturbing the state of the FPGA based system. The presented system has been verified in the hardware, and may be used as a tool for debugging, testing and even implementing of control algorithms for FPGA based systems.

  10. Carbazole functionalized isocyanide brushes in heterojunction photovoltaic devices

    NARCIS (Netherlands)

    Lim, E.; Gao, F.; Schwartz, E.; Schwartz, E.; Cornelissen, Jeroen Johannes Lambertus Maria; Nolte, R.J.M.; Rowan, A.E.; Greenham, N.C.; Do, L.M.

    2012-01-01

    In this work, carbazole-containing polyisocyanide (PIACz) brushes were used for photovoltaic devices. A photovoltaic device was fabricated on top of the brushes by spin-coating a suitable acceptor and evaporating an Al cathode. Devices with a poly(N-vinylcarbazole) (PVK) bulk polymer were also

  11. Learning characteristics of a space-time neural network as a tether skiprope observer

    Science.gov (United States)

    Lea, Robert N.; Villarreal, James A.; Jani, Yashvant; Copeland, Charles

    1993-01-01

    The Software Technology Laboratory at the Johnson Space Center is testing a Space Time Neural Network (STNN) for observing tether oscillations present during retrieval of a tethered satellite. Proper identification of tether oscillations, known as 'skiprope' motion, is vital to safe retrieval of the tethered satellite. Our studies indicate that STNN has certain learning characteristics that must be understood properly to utilize this type of neural network for the tethered satellite problem. We present our findings on the learning characteristics including a learning rate versus momentum performance table.

  12. Trace gas measurements from tethered balloon platforms

    Science.gov (United States)

    Bandy, Alan R.; Bandy, Terese L.; Youngbluth, Otto; Owens, Thomas L.

    1987-01-01

    Instrumentation and chemical sampling and analysis procedures are described for making measurements of atmospheric carbon disulfide in the concentration range 1-1000 pptv from tethered balloon platforms. Results of a study on the CS2 composition of air downward of a saltwater marsh are reported. A method for obtaining the necessary data for solving the budget equations for surface fluxes, chemical formation rates and chemical destruction rates using data acquired from tethered balloon platforms is presented.

  13. Transitions of tethered chain molecules under tension.

    Science.gov (United States)

    Luettmer-Strathmann, Jutta; Binder, Kurt

    2014-09-21

    An applied tension force changes the equilibrium conformations of a polymer chain tethered to a planar substrate and thus affects the adsorption transition as well as the coil-globule and crystallization transitions. Conversely, solvent quality and surface attraction are reflected in equilibrium force-extension curves that can be measured in experiments. To investigate these effects theoretically, we study tethered chains under tension with Wang-Landau simulations of a bond-fluctuation lattice model. Applying our model to pulling experiments on biological molecules we obtain a good description of experimental data in the intermediate force range, where universal features dominate and finite size effects are small. For tethered chains in poor solvent, we observe the predicted two-phase coexistence at transitions from the globule to stretched conformations and also discover direct transitions from crystalline to stretched conformations. A phase portrait for finite chains constructed by evaluating the density of states for a broad range of solvent conditions and tensions shows how increasing tension leads to a disappearance of the globular phase. For chains in good solvents tethered to hard and attractive surfaces we find the predicted scaling with the chain length in the low-force regime and show that our results are well described by an analytical, independent-bond approximation for the bond-fluctuation model for the highest tensions. Finally, for a hard or slightly attractive surface the stretching of a tethered chain is a conformational change that does not correspond to a phase transition. However, when the surface attraction is sufficient to adsorb a chain it will undergo a desorption transition at a critical value of the applied force. Our results for force-induced desorption show the transition to be discontinuous with partially desorbed conformations in the coexistence region.

  14. Wildlife responses to brush management: a contemporary evaluation

    Science.gov (United States)

    Brush management has been widely practiced with the general intent of curtailing or reversing the proliferation of shrubs and trees in grasslands and savannas. The traditional aim of brush management has been to increase livestock forage or to improve water yield. Its potential role for restoring h...

  15. Dynamic analysis of the tether transportation system using absolute nodal coordinate formulation

    Science.gov (United States)

    Sun, Xin; Xu, Ming; Zhong, Rui

    2017-10-01

    Long space tethers are becoming a rising concern as an alternate way for transportation in space. It benefits from fuel economizing. This paper focuses on the dynamics of the tether transportation system, which consists of two end satellites connected by a flexible tether, and a movable vehicle driven by the actuator carried by itself. The Absolute Nodal Coordinate Formulation is applied to the establishment of the equation of motion, so that the influence caused by the distributed mass and elasticity of the tether is introduced. Moreover, an approximated method for accelerating the calculation of the generalized gravitational forces on the tether is proposed by substituting the volume integral every step into summation of finite terms. Afterwards, dynamic evolutions of such a system in different configurations are illustrated using numerical simulations. The deflection of the tether and the trajectory of the crawler during the transportation is investigated. Finally, the effect on the orbit of the system due to the crawler is revealed.

  16. Design and Testing of High Performance Brushes.

    Science.gov (United States)

    1983-05-01

    shows an example. What ordinarily serves as a ’brush’. applitations such as homopolar motors / generators and in transmitting current across an interface...speed current collection bricating layer of silver and graphite debris. systems for homopolar electrical machines. Use The other, associated with the...performantc hornopolar by examining the origin of the power losses when electrical motors and generators, based either on superconducting or brushes

  17. 21 CFR 868.5795 - Tracheal tube cleaning brush.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheal tube cleaning brush. 868.5795 Section 868.5795 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5795 Tracheal tube cleaning brush. (a...

  18. Thrust Control During Towing of Space Debris using an Elastic Tether

    Directory of Open Access Journals (Sweden)

    A. D. Ledkov

    2014-01-01

    Full Text Available The paper considers a maneuver for deorbiting the large space debris using an active spacecraft connected with the debris by an elastic tether. Tether slacking during the maneuver can lead to the tether rupture, kinking, and winding on the descending object. Therefore it is important to prevent slacking. The objective of this work is to find the law of thrust force control of the active spacecraft to ensure a continuously strained tether during the maneuver.Using Lagrange formalism a mathematical model to describe the system plane motion is developed. This model considers the active spacecraft as a mass point, the space debris as a rigid body, and the tether as a weightless elastic rod. A thrust force is directed along the local horizon of the spacecraft. Linearization of nonlinear differential equation describing longitudinal oscillations of the tether length is performed. Its phase portrait is analyzed. An approximate expression describing the position of the center on the phase portrait is obtained. A time-optimal control with full feedback to ensure that the tether is in the strained state is found by solving the Bellman equation. To use the obtained optimal law it is necessary to set the measuring equipment on the spacecraft, which is capable of accurate measuring a distance to the space debris and its relative velocity. An alternative control law, which is simpler in terms of the practical implementation, is proposed. As an example, the descent from an orbit of nonfunctioning Soviet satellite Meteor-2 is considered. It is shown that both proposed laws provide continuous strain of the tether during deorbiting of the satellite. Moreover, slack does not occur even at the first period of oscillation of the tether length. It is shown that the use of the proposed control laws leads to slight increase of deorbiting time as compared to the case of using the constant thrust.The results can be used to develop the control systems of small spacecrafts

  19. Sonography compared with MR imaging in the evaluation of card tethering following myelomeningocele repair

    International Nuclear Information System (INIS)

    Newman, B.; Bowen, A.; Albright, L.

    1989-01-01

    This paper reports on MR imaging and videotaped US spine examinations to evaluate cord tethering were retrospectively compared in 12 children with prior myelomeningocele repair and correlated with clinical and surgical findings. Although US did not delineate normal or abnormal anatomy as well as MR imaging, both types of studies confirmed the presence of tethering in 10 patients. One child with a normal US examination and abnormal MR images had tethering confirmed surgically. A second child had a US study suggestive of tethering with equivocal MR images. Postoperative studies in eight patients correlated less well; US suggested persistent tethering in five patients and MR imaging indicated tethering in two

  20. Effect of Frequency of Brushing Teeth on Plaque and Calculus Accumulation, and Gingivitis in Dogs.

    Science.gov (United States)

    Harvey, Colin; Serfilippi, Laurie; Barnvos, Donald

    2015-01-01

    The efficacy of brushing the teeth of beagle dogs in a randomized, controlled, blinded study design using a clearly-defined brushing technique was evaluated for 4 brushing frequencies: brushing daily, brushing every other day, brushing weekly and brushing every other week, compared with no brushing in a control group of dogs. All dogs were fed a standard dry kibble diet during the study. Standard plaque, calculus, and gingivitis indices were used to score the teeth. A 'clean tooth' model was used. No gingival or non-gingival lacerations or other signs of injury to oral tissues were found at the end of the 28 day trial period. Brushing more frequently had greater effectiveness in retarding accumulation of plaque and calculus, and reducing the severity of pre-existing gingivitis. Brushing daily or every other day produced statistically significant improved results compared with brushing weekly or every other week. Based on the results of this study, daily brushing is recommended.

  1. Tooth brushing, tongue cleaning and snacking behaviour of dental technology and therapist students

    Directory of Open Access Journals (Sweden)

    Clement C. Azodo

    2010-08-01

    Full Text Available Objective: To determine the tooth brushing, tongue cleaning and snacking behaviour of dental technology and therapist students. Methods: A descriptive cross-sectional study of students of Federal School of Dental Therapy and Technology Enugu, Nigeria. Self-administered questionnaire was used to obtain information on demography, frequency, duration and technique of tooth brushing and tongue cleaning as well as information on consumption of snacks. Results: A total of 242 students responded. Dental technology students made up 52.5% of the respondents and dental therapist in training made up 47.5%. Majority (63.2% of the respondents considered the strength of tooth brush when purchasing a tooth brush and 78.9% use tooth brushes with medium strength. Seven-tenth (71.9% of the respondents brush their teeth twice daily and 52.1% brush for 3–5 minutes. About one-third (30.2% brush their teeth in front of a mirror. Chewing stick was used by 51.7% of respondents in addition to the use of tooth brush. Tongue cleaning was done by 94.2% with only 9.5% using a tongue cleaner. Only 20.2% reported regular snacks consumption. Nine-tenth (90.4% of respondents were previously involved in educating others, apart from their colleagues, on tooth brushing. Conclusion: This survey revealed that most of the dental therapy and technology students had satisfactory tooth-brushing behaviour. The zeal to educate others about proper tooth brushing revealed in this study suggests that the students may be helpful in oral health promotion.

  2. High-field MR imaging of tethered cord

    International Nuclear Information System (INIS)

    Sigal, R.; Bicetre, L.; Blass, C.; Doyon, D.; Pariente, D.

    1986-01-01

    MR imaging examinations of 12 patients with tethered cord syndrome have been performed on a 1.5-T MR imaging unit. Patients ranged in age from 3 to 60 years. MR findings were compared with those of myelography and metrizamide CT in all cases. Five patients underwent surgical control and postoperative MR imaging. Sagittal and axial sections were obtained using a spin-echo multisection, multiecho technique. T1-axial weighted images (SE 600/25) were sufficient to locate the position of the tip of the conus. They also allowed identification of extraspinal and intraspinal lipomas and clear-cut demarcation form associated tethered cord. Drawbacks of MR imaging were lack of precise depiction of the bone structures and the fact that clear identification of abnormal roots was problematic. The craniovertebral junction was always checked; two asymptomatic Chiari malformations were visualized. This study leads the authors to conclude that MR imaging should be used as the examination of first choice in the management of tethered cord syndrome

  3. The investigation of tethered satellite system dynamics

    Science.gov (United States)

    Lorenzini, E. C.

    1986-01-01

    The analysis of the rotational dynamics of the satellite was focused on the rotational amplitude increase of the satellite, with respect to the tether, during retrieval. The dependence of the rotational amplitude upon the tether tension variation to the power 1/4 was thoroughly investigated. The damping of rotational oscillations achievable by reel control was also quantified while an alternative solution that makes use of a lever arm attached with a universal joint to the satellite was proposed. Comparison simulations between the Smithsonian Astrophysical Observatory and the Martin Marietta (MMA) computer code of reteival maneuvers were also carried out. The agreement between the two, completely independent, codes was extremely close, demonstrating the reliability of the models. The slack tether dynamics during reel jams was analytically investigated in order to identify the limits of applicability of the SLACK3 computer code to this particular case. Test runs with SLACK3 were also carried out.

  4. Spontaneous bending of 2D molecular bottle-brush

    NARCIS (Netherlands)

    Subbotin, A; Jong, J; ten Brinke, G

    Using a scaling approach we consider a 2D comb copolymer brush under bending deformations. We show that the rectilinear brush is locally stable and can be characterized by a persistence length lambda increasing with the molecular weight of grafting side chains as lambda similar to M-3. A bending

  5. Vesicle fusion observed by content transfer across a tethered lipid bilayer.

    Science.gov (United States)

    Rawle, Robert J; van Lengerich, Bettina; Chung, Minsub; Bendix, Poul Martin; Boxer, Steven G

    2011-10-19

    Synaptic transmission is achieved by exocytosis of small, synaptic vesicles containing neurotransmitters across the plasma membrane. Here, we use a DNA-tethered freestanding bilayer as a target architecture that allows observation of content transfer of individual vesicles across the tethered planar bilayer. Tethering and fusion are mediated by hybridization of complementary DNA-lipid conjugates inserted into the two membranes, and content transfer is monitored by the dequenching of an aqueous content dye. By analyzing the diffusion profile of the aqueous dye after vesicle fusion, we are able to distinguish content transfer across the tethered bilayer patch from vesicle leakage above the patch. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  6. Alcohol versus brush PRK: visual outcomes and adverse effects.

    Science.gov (United States)

    Sia, Rose K; Ryan, Denise S; Stutzman, Richard D; Psolka, Maximilian; Mines, Michael J; Wagner, Melvin E; Weber, Eric D; Wroblewski, Keith J; Bower, Kraig S

    2012-08-01

    A smooth corneal surface prior to laser ablation is important in order to achieve a favorable refractive outcome. In this study, we compare PRK outcomes following two commonly used methods of epithelial debridement: Amoils epithelial scrubber (brush) versus 20% ethanol (alcohol). We reviewed records of patients who underwent wavefront-optimized PRK for myopia or myopic astigmatism between January 2008 and June 2010. Two treatment groups (brush vs. alcohol) were compared in terms of uncorrected distance visual acuity (UDVA), manifest refraction spherical equivalent (MRSE), corrected distance visual acuity (CDVA), and complications at postoperative months 1, 3, 6, and 12. One thousand five hundred ninety-three eyes of 804 patients underwent PRK during the study period: 828 brush-treated eyes and 765 alcohol-treated eyes. At 6 months postoperatively UDVA was ≥20/20 in 94.7% of brush-treated eyes versus 94.4% of alcohol-treated eyes (P = 0.907). At 1 month a higher percentage of brush-treated eyes maintained or gained one or more lines CDVA compared to alcohol-treated eyes (P = 0.007), but there were no other differences in UDVA, MRSE, or CDVA at any point postoperatively. At 1 month 75.4% of brush-treated eyes versus 70.4% of alcohol-treated eyes were free of complications (P = 0.032), and there were fewer brush-treated eyes with corneal haze (4.0% vs. 6.9%, P = 0.012) and dry eye (8.9% vs. 14.4%, P = 0.001). Although corneal haze was slightly more frequent in the alcohol group, most was trace and not significant. Although alcohol-assisted PRK had more minor complications in the early postoperative period, including corneal haze and dry eye, results for both groups beyond 1 month were comparable. Copyright © 2012 Wiley Periodicals, Inc.

  7. Shroud brushing device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo; Takabayashi, Jun-ichi.

    1996-01-01

    A roller screw is assembled at an axial center of the inside of a device main body. A nut is assembled to the axial center of the roller screw secured so as not to be rotated, and a base is integrally connected to the nut. An air cylinder is pivoted to the base by a pin, and an arm is disposed to a piston rod of the air cylinder. The top end of the arm is secured to a motor case, and a brush is rotated by an electric motor in the motor case. The device main body is suspended into the reactor pressure vessel of a BWR type reactor, and seated on the upper surface of a fuel support metal fitting. The roller screw is rotated to move vertically the arm by way of the nut and the base. The device main body is rotated to rotate the arm. The arm is extended and then the electric motor is driven to rotate the brush thereby polishing the inner surface of the shroud. (I.N.)

  8. Shroud brushing device

    Energy Technology Data Exchange (ETDEWEB)

    Sakamaki, Kazuo; Takabayashi, Jun-ichi

    1996-07-12

    A roller screw is assembled at an axial center of the inside of a device main body. A nut is assembled to the axial center of the roller screw secured so as not to be rotated, and a base is integrally connected to the nut. An air cylinder is pivoted to the base by a pin, and an arm is disposed to a piston rod of the air cylinder. The top end of the arm is secured to a motor case, and a brush is rotated by an electric motor in the motor case. The device main body is suspended into the reactor pressure vessel of a BWR type reactor, and seated on the upper surface of a fuel support metal fitting. The roller screw is rotated to move vertically the arm by way of the nut and the base. The device main body is rotated to rotate the arm. The arm is extended and then the electric motor is driven to rotate the brush thereby polishing the inner surface of the shroud. (I.N.)

  9. Daylong Effect of Tooth Brushing or Combination Tooth Brushing and Tongue Cleaning Using Antiplaque®Toothpaste on Volatile Sulphur Compound Levels

    Directory of Open Access Journals (Sweden)

    Indriasti Indah Wardhany

    2013-07-01

    Full Text Available Objective: to determine the daylong effect of Antiplaque® toothpaste active copound and the effect of tooth brushing or combination of tooth brushing and tongue cleaning on Volatile Sulphur Compounds (VSC levels. Methods: Clinical experimental double blinded microbiological and clinical examination. Subjects mainly from dental faculty student with or without a chief complain of halitosis. One hundred and twenty subjects were divided into four groups that consist of thirty samples each group. Two group are treatment subjects were divided into four groups that consist thirty samples each group. Two groups are treatment groups using Antiplaque® toothpaste and two groups are control groups using placebo toothpaste. The daylong effects of VSC levels are measured by Halimeter and organoleptic. The intraoral status were measured including periodontal status and tongue index. Result: There are a reduction of VSC levels in both treatment and control group, but the reduction only significant in group using Antiplaque® toothpaste (Wilcoxon signed rank test, p<0.05. There are a reduction of VSC levels in both treatment using Antiplaque® toothpaste, but the combination of tooth brushing and tongue cleaning reduced VSC levels significantly lower than tooth brushing treatment (Mann Whitney U test, P,0.05. Conclusion: Tooth brushing and tongue cleaning using Antiplaque® toothpaste significantly reduced VSC levels.DOI: 10.14693/jdi.v16i2.95

  10. Fouling-resistant polymer brush coatings

    KAUST Repository

    Thérien-Aubin, Héloïse

    2011-11-01

    A major problem to be addressed with thin composite films used in processes such as coatings or water purification is the biofouling of the surface. To address this problem in a model system, functionalized polyaramide membranes containing an atom transfer radical polymerization (ATRP) initiator were synthesized as a versatile approach to easily modify the surface properties of the polyaramide. Poly(methacrylic acid) brushes were grown using surface initiated ATRP followed by the functionalization of the poly(methacrylic acid) brushes with different side-chains chosen to reduce adhesion between the membrane and foulant. The relation between membrane fouling and the physicochemical properties of the surface was investigated in detail. © 2011 Elsevier Ltd. All rights reserved.

  11. Fouling-resistant polymer brush coatings

    KAUST Repository

    Thé rien-Aubin, Hé loï se; Chen, Lin; Ober, Christopher K.

    2011-01-01

    A major problem to be addressed with thin composite films used in processes such as coatings or water purification is the biofouling of the surface. To address this problem in a model system, functionalized polyaramide membranes containing an atom transfer radical polymerization (ATRP) initiator were synthesized as a versatile approach to easily modify the surface properties of the polyaramide. Poly(methacrylic acid) brushes were grown using surface initiated ATRP followed by the functionalization of the poly(methacrylic acid) brushes with different side-chains chosen to reduce adhesion between the membrane and foulant. The relation between membrane fouling and the physicochemical properties of the surface was investigated in detail. © 2011 Elsevier Ltd. All rights reserved.

  12. Radiocesium movement in a gray rabbit brush community

    International Nuclear Information System (INIS)

    Klepper, B.; Rogers, L.E.; Hedlund, J.D.; Schreckhise, R.G.; Price, K.R.

    1978-01-01

    Gray rabbit brush, Chrysothamnus nauseosus (Compositae), is the dominant shrub on disturbed land surfaces on much of the Energy Research and Development Administration's Hanford Reservation in south-central Washington State. A stand of rabbit brush growing on an inactive liquid-waste-disposal crib was studied. Thirty percent of the shrubs showed low but detectable radiation levels in a field survey. The primary radionuclide was 137 Cs. The source of 137 Cs in shrubs was the gravel drain field in the crib, at least 2.4 m below the surface, which was the approximate maximum depth of penetration of rabbit brush taproots. Cesium-137 was observed in roots of certain rabbit brush plants, in the upper 1 cm of soil, and in litter beneath contaminated plants but was not detectable in soil samples taken at depths of 15, 50, 100, and 150 cm. Invertebrates associated with a contaminated shrub showed higher concentrations of 137 Cs than did wider-ranging species. Two of seven pocket mice trapped on the crib contaminated detectable amounts of 137 Cs

  13. Hierarchical Structure in Semicrystalline Polymers Tethered to Nanospheres

    KAUST Repository

    Kim, Sung A

    2014-01-28

    We report on structural and dynamic transitions of polymers tethered to nanoparticles. In particular, we use X-ray diffraction, vibrational spectroscopy, and thermal measurements to investigate multiscale structure and dynamic transitions of poly(ethylene glycol) (PEG) chains densely grafted to SiO2 nanoparticles. The approach used for synthesizing these hybrid particles leads to homogeneous SiO2-PEG composites with polymer grafting densities as high as 1.5 chains/nm2, which allows the hybrid materials to exist as self-suspended suspensions with distinct hierarchical structure and thermal properties. On angstrom and nanometer length scales, the tethered PEG chains exhibit more dominant TTG conformations and helix unit cell structure, in comparison to the untethered polymer. The nanoparticle tethered PEG chains are also reported to form extended crystallites on tens of nanometers length scales and to exhibit more stable crystalline structure on small dimensions. On length scales comparable to the size of each hybrid SiO 2-PEG unit, the materials are amorphous presumably as a result of the difficulty fitting the nanoparticle anchors into the PEG crystal lattice. This structural change produces large effects on the thermal transitions of PEG molecules tethered to nanoparticles. © 2014 American Chemical Society.

  14. NASA Langley Research Center tethered balloon systems

    Science.gov (United States)

    Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto

    1987-01-01

    The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.

  15. Design optimization of a brush turbine with a cleaner/water based solution

    Science.gov (United States)

    Kim, Rhyn H.

    1995-01-01

    Recently, a turbine-brush was analyzed based on the energy conservation and the force momentum equation with an empirical relationship of the drag coefficient. An equation was derived to predict the rotational speed of the turbine-brush in terms of the blade angle, number of blades, rest of geometries of the turbine-brush and the incoming velocity. Using the observed flow conditions, drag coefficients were determined. Based on the experimental values as boundary conditions, the turbine-brush flows were numerically simulated to understand first the nature of the flows, and to extend the observed drag coefficient to a flow without holding the turbine-brush.

  16. Keep Kids' Mouths Healthy: Brush 2min2X

    Science.gov (United States)

    Make sure your kids brush for 2 minutes, twice a day. En Español facebook twitter instagram Kids’ Healthy Mouths Health Watch & Brush! Watch ... About Kids’ Teeth Teeth Helpful Resources Links Keep Kids’ Mouths Healthy Roll over or click the time ...

  17. Tethered catalysts for the hydration of carbon dioxide

    Science.gov (United States)

    Valdez, Carlos A; Satcher, Jr., Joe H; Aines, Roger D; Wong, Sergio E; Baker, Sarah E; Lightstone, Felice C; Stolaroff, Joshuah K

    2014-11-04

    A system is provided that substantially increases the efficiency of CO.sub.2 capture and removal by positioning a catalyst within an optimal distance from the air-liquid interface. The catalyst is positioned within the layer determined to be the highest concentration of carbon dioxide. A hydrophobic tether is attached to the catalyst and the hydrophobic tether modulates the position of the catalyst within the liquid layer containing the highest concentration of carbon dioxide.

  18. Numerical Simulation of Tethered Underwater Kites for Power Generation

    Science.gov (United States)

    Ghasemi, Amirmahdi; Olinger, David; Tryggvason, Gretar

    2015-11-01

    An emerging renewable energy technology, tethered undersea kites (TUSK), which is used to extract hydrokinetic energy from ocean and tidal currents, is studied. TUSK systems consist of a rigid-winged ``kite,'' or glider, moving in an ocean current which is connected by tethers to a floating buoy on the ocean surface. The TUSK kite is a current speed enhancement device since the kite can move in high-speed, cross-current motion at 4-6 times the current velocity, thus producing more power than conventional marine turbines. A computational simulation is developed to simulate the dynamic motion of an underwater kite and extendable tether. A two-step projection method within a finite volume formulation, along with an Open MP acceleration method, is employed to solve the Navier-Stokes equations. An immersed boundary method is incorporated to model the fluid-structure interaction of the rigid kite (with NACA 0012 airfoil shape in 2D and NACA 0021 airfoil shape in 3D simulations) and the fluid flow. PID control methods are used to adjust the kite angle of attack during power (tether reel-out) and retraction (reel-in) phases. Two baseline simulations (for kite motions in two and three dimensions) are studied, and system power output, flow field vorticity, tether tension, and hydrodynamic coefficients (lift and drag) for the kite are determined. The simulated power output shows good agreement with established theoretical results for a kite moving in two-dimensions.

  19. Biomimicry enhances sequential reactions of tethered glycolytic enzymes, TPI and GAPDHS.

    Directory of Open Access Journals (Sweden)

    Chinatsu Mukai

    Full Text Available Maintaining activity of enzymes tethered to solid interfaces remains a major challenge in developing hybrid organic-inorganic devices. In nature, mammalian spermatozoa have overcome this design challenge by having glycolytic enzymes with specialized targeting domains that enable them to function while tethered to a cytoskeletal element. As a step toward designing a hybrid organic-inorganic ATP-generating system, we implemented a biomimetic site-specific immobilization strategy to tether two glycolytic enzymes representing different functional enzyme families: triose phosphoisomerase (TPI; an isomerase and glyceraldehyde 3-phosphate dehydrogenase (GAPDHS; an oxidoreductase. We then evaluated the activities of these enzymes in comparison to when they were tethered via classical carboxyl-amine crosslinking. Both enzymes show similar surface binding regardless of immobilization method. Remarkably, specific activities for both enzymes were significantly higher when tethered using the biomimetic, site-specific immobilization approach. Using this biomimetic approach, we tethered both enzymes to a single surface and demonstrated their function in series in both forward and reverse directions. Again, the activities in series were significantly higher in both directions when the enzymes were coupled using this biomimetic approach versus carboxyl-amine binding. Our results suggest that biomimetic, site-specific immobilization can provide important functional advantages over chemically specific, but non-oriented attachment, an important strategic insight given the growing interest in recapitulating entire biological pathways on hybrid organic-inorganic devices.

  20. Biomimicry enhances sequential reactions of tethered glycolytic enzymes, TPI and GAPDHS.

    Science.gov (United States)

    Mukai, Chinatsu; Gao, Lizeng; Bergkvist, Magnus; Nelson, Jacquelyn L; Hinchman, Meleana M; Travis, Alexander J

    2013-01-01

    Maintaining activity of enzymes tethered to solid interfaces remains a major challenge in developing hybrid organic-inorganic devices. In nature, mammalian spermatozoa have overcome this design challenge by having glycolytic enzymes with specialized targeting domains that enable them to function while tethered to a cytoskeletal element. As a step toward designing a hybrid organic-inorganic ATP-generating system, we implemented a biomimetic site-specific immobilization strategy to tether two glycolytic enzymes representing different functional enzyme families: triose phosphoisomerase (TPI; an isomerase) and glyceraldehyde 3-phosphate dehydrogenase (GAPDHS; an oxidoreductase). We then evaluated the activities of these enzymes in comparison to when they were tethered via classical carboxyl-amine crosslinking. Both enzymes show similar surface binding regardless of immobilization method. Remarkably, specific activities for both enzymes were significantly higher when tethered using the biomimetic, site-specific immobilization approach. Using this biomimetic approach, we tethered both enzymes to a single surface and demonstrated their function in series in both forward and reverse directions. Again, the activities in series were significantly higher in both directions when the enzymes were coupled using this biomimetic approach versus carboxyl-amine binding. Our results suggest that biomimetic, site-specific immobilization can provide important functional advantages over chemically specific, but non-oriented attachment, an important strategic insight given the growing interest in recapitulating entire biological pathways on hybrid organic-inorganic devices.

  1. Tethered Ozonesonde Measurements During FRAPPE July-August 2014

    Science.gov (United States)

    Oltmans, S. J.; Johnson, B.; Sterling, C. W.; Cullis, P.; Hall, E. G.; Jordan, A. F.; Wendell, J.; Schnell, R. C.; McClure-Begley, A.; Thompson, A. M.

    2015-12-01

    O3 and temperature profiles were measured from tethered ozonesondes from surface to 400 m above ground level on 9 days during the summer of 2014 Colorado Front Range Air Pollution and Photochemistry Experiment (FRAPPE). The portable tethered ozonesonde system was set up at one of 3 sites located next to a Colorado Department of Public Health and Environment surface monitoring station. The day and site chosen were based on the previous day O3 and weather forecast. Measurements typically began at 8:30 AM and ended at 4:30 PM, averaging 40 profiles in one day. The ozonesonde when sampling at the surface consistently read within 0-3 ppbv of the surface monitor at each of the sites with a typical daytime range of 20-90 ppbv. The hourly values were averaged at 50 meter intervals showing O3 production rates were consistently around 8 ppbv per hour from 50 to 300 meters above ground level. On sunny, light wind days the O3 mixing ratio reached a maximum of 80-90 ppbv between 14:00 and 15:00 local time. The generally constant mixing ratio with height and highest mixing ratios above the surface indicate that photochemical O3 production was taking place throughout the profile. Continuous O3 profiles from a tall tower (5 and 300 m) and daily ozonesondes tracked O3 variability through the experiment. High O3 at each site was associated with different local wind directions. At Ft. Collins winds were generally out of the southeast, at Chatfield from the northeast, and at City Park Golf Course more variable. The tether system was developed at NOAA/ESRL to provide a cost effective method to measure O3 profiles on a continuous basis. The tether system consisted of a deep sea fishing pole, electric motor driving the reel with light-weight fishing line attached to the balloon ozonesonde, a tether control box, and laptop. The in house software package monitored data and controlled the tether speed and turn-around point based on real time GPS altitude from the transmitting radiosonde.

  2. An Effective Approach Control Scheme for the Tethered Space Robot System

    Directory of Open Access Journals (Sweden)

    Zhongjie Meng

    2014-09-01

    Full Text Available The tethered space robot system (TSR, which is composed of a platform, a gripper and a space tether, has great potential in future space missions. Given the relative motion among the platform, tether, gripper and the target, an integrated approach model is derived. Then, a novel coordinated approach control scheme is presented, in which the tether tension, thrusters and the reaction wheel are all utilized. It contains the open-loop trajectory optimization, the feedback trajectory control and attitude control. The numerical simulation results show that the rendezvous between TSR and the target can be realized by the proposed coordinated control scheme, and the propellant consumption is efficiently reduced. Moreover, the control scheme performs well in the presence of the initial state's perturbations, actuator characteristics and sensor errors.

  3. Modelling a tethered mammalian sperm cell undergoing hyperactivation

    KAUST Repository

    Curtis, M.P.

    2012-09-01

    The beat patterns of mammalian sperm flagella can be categorised into two different types. The first involves symmetric waves propagating down the flagellum with a net linear propulsion of the sperm cell. The second, hyperactive, waveform is classified by vigorous asymmetric waves of higher amplitude, lower wavenumber and frequency propagating down the flagellum resulting in highly curved trajectories. The latter beat pattern is part of the capacitation process whereby sperm prepare for the prospective penetration of the zona pellucida and fusion with the egg. Hyperactivation is often observed to initiate as sperm escape from epithelial and ciliary bindings formed within the isthmic regions of the female oviducts, leading to a conjecture in the literature that this waveform is mechanically important for sperm escape. Hence, we explore the mechanical effects of hyperactivation on a tethered sperm, focussing on a Newtonian fluid. Using a resistive force theory model we demonstrate that hyperactivation can indeed generate forces that pull the sperm away from a tethering point and consequently a hyperactivated sperm cell bound to an epithelial surface need not always be pushed by its flagellum. More generally, directions of the forces generated by tethered flagella are insensitive to reductions in beat frequency and the detailed flagellar responses depend on the nature of the binding at the tethering point. Furthermore, waveform asymmetry and amplitude increases enhance the tendency for a tethered flagellum to start tugging on its binding. The same is generally predicted to be true for reductions in the wavenumber of the flagellum beat, but not universally so, emphasising the dynamical complexity of flagellar force generation. Finally, qualitative observations drawn from experimental data of human sperm bound to excised female reproductive tract are also presented and are found to be consistent with the theoretical predictions. © 2012 Elsevier Ltd.

  4. Modelling a tethered mammalian sperm cell undergoing hyperactivation

    KAUST Repository

    Curtis, M.P.; Kirkman-Brown, J.C.; Connolly, T.J.; Gaffney, E.A.

    2012-01-01

    The beat patterns of mammalian sperm flagella can be categorised into two different types. The first involves symmetric waves propagating down the flagellum with a net linear propulsion of the sperm cell. The second, hyperactive, waveform is classified by vigorous asymmetric waves of higher amplitude, lower wavenumber and frequency propagating down the flagellum resulting in highly curved trajectories. The latter beat pattern is part of the capacitation process whereby sperm prepare for the prospective penetration of the zona pellucida and fusion with the egg. Hyperactivation is often observed to initiate as sperm escape from epithelial and ciliary bindings formed within the isthmic regions of the female oviducts, leading to a conjecture in the literature that this waveform is mechanically important for sperm escape. Hence, we explore the mechanical effects of hyperactivation on a tethered sperm, focussing on a Newtonian fluid. Using a resistive force theory model we demonstrate that hyperactivation can indeed generate forces that pull the sperm away from a tethering point and consequently a hyperactivated sperm cell bound to an epithelial surface need not always be pushed by its flagellum. More generally, directions of the forces generated by tethered flagella are insensitive to reductions in beat frequency and the detailed flagellar responses depend on the nature of the binding at the tethering point. Furthermore, waveform asymmetry and amplitude increases enhance the tendency for a tethered flagellum to start tugging on its binding. The same is generally predicted to be true for reductions in the wavenumber of the flagellum beat, but not universally so, emphasising the dynamical complexity of flagellar force generation. Finally, qualitative observations drawn from experimental data of human sperm bound to excised female reproductive tract are also presented and are found to be consistent with the theoretical predictions. © 2012 Elsevier Ltd.

  5. Single-chain-in-mean-field simulations of weak polyelectrolyte brushes

    Science.gov (United States)

    Léonforte, F.; Welling, U.; Müller, M.

    2016-12-01

    Structural properties of brushes which are composed of weak acidic and basic polyelectrolytes are studied in the framework of a particle-based approach that implicitly accounts for the solvent quality. Using a semi-grandcanonical partition function in the framework of the Single-Chain-in-Mean-Field (SCMF) algorithm, the weak polyelectrolyte is conceived as a supramolecular mixture of polymers in different dissociation states, which are explicitly treated in the partition function and sampled by the SCMF procedure. One obtains a local expression for the equilibrium acid-base reaction responsible for the regulation of the charged groups that is also incorporated to the SCMF sampling. Coupled to a simultaneous treatment of the electrostatics, the approach is shown to capture the main features of weak polyelectrolyte brushes as a function of the bulk pH in the solution, the salt concentration, and the grafting density. Results are compared to experimental and theoretical works from the literature using coarse-grained representations of poly(acrylic acid) (PAA) and poly(2-vinyl pyridine) (P2VP) polymer-based brushes. As the Born self-energy of ions can be straightforwardly included in the numerical approach, we also study its effect on the local charge regulation mechanism of the brush. We find that its effect becomes significant when the brush is dense and exposed to high salt concentrations. The numerical methodology is then applied (1) to the study of the kinetics of collapse/swelling of a P2VP brush and (2) to the ability of an applied voltage to induce collapse/swelling of a PAA brush in a pH range close to the pKa value of the polymer.

  6. Uptake of pH-Sensitive Gold Nanoparticles in Strong Polyelectrolyte Brushes

    Directory of Open Access Journals (Sweden)

    Dikran Kesal

    2016-04-01

    Full Text Available The impact of electrostatic attraction on the uptake of gold nanoparticles (AuNPs into positively charged strong poly-[2-(Methacryloyloxy ethyl] trimethylammonium chloride (PMETAC polyelectrolyte brushes was investigated. In this work, PMETAC brushes were synthesized via surface-initiated atom transfer radical polymerization (Si-ATRP. PMETAC/AuNP composite materials were prepared by incubation of the polymer brush coated samples into 3-mercaptopropionic acid-capped AuNP (5 nm in diameter suspension. The electrostatic interactions were tuned by changing the surface charge of the AuNPs through variations in pH value, while the charge of the PMETAC brush was not affected. Atomic-force microscopy (AFM, ellipsometry, UV/Vis spectroscopy, gravimetric analysis and transmission electron microscopy (TEM were employed to study the loading and penetration into the polymer brush. The results show that the number density of attached AuNPs depends on the pH value and increases with increasing pH value. There is also strong evidence that the particle assembly is dependent on the pH value of the AuNP suspension. Incubation of PMETAC brushes in AuNP suspension at pH 4 led to the formation of a surface layer on top of the brush (2D assembly due to sterical hindrance of the clustered AuNPs, while incubation in AuNP suspension at pH 8 led to deeper particle penetration into the brush (3D assembly. The straightforward control of particle uptake and assembly by tuning the charge density of the nanoparticle surface is a valuable tool for the development of materials for colorimetric sensor applications.

  7. Functional patterns obtained by nanoimprinting lithography and subsequent growth of polymer brushes

    International Nuclear Information System (INIS)

    Genua, A; AlduncIn, J A; Pomposo, J A; Grande, H; Kehagias, N; Reboud, V; Sotomayor, C; Mondragon, I; Mecerreyes, D

    2007-01-01

    In this work the growth of polymer brushes was combined with nanoimprint lithography (NIL) in order to obtain new functional nanopatterns. First, a functional thermoplastic methacrylic copolymer poly(methyl methacrylate-co-2-bromoisobutyryl-oxy-ethyl methacrylate) was synthesized. This copolymer was successfully patterned by NIL using a silicon stamp at 160 deg. C and 60 bar. Next, hydrophilic polymer brushes based on poly(3-sulfopropylmethacrylate) and hydrophobic polymer brushes based on a poly(fluorinated methacrylate) were grown on the imprinted surfaces. The surface properties of the patterned polymer were accordingly modified and, as a consequence, the water contact angle was modified from 80.3 deg. to 32.5 deg. in the case of the hydrophilic brushes and to 118.1 deg. in the case of the hydrophobic brushes. As an application we demonstrated the use of hydrophobic polymer brushes in order to modify the surface of polymeric stamps for NIL with self-demoulding properties

  8. Tethered elevator and platforms as space station facilities: Systems studies and demonstrative experiments

    Science.gov (United States)

    1986-01-01

    Several key concepts of the science and applications tethered platforms were studied. Some conclusions reached are herein listed. Tether elevator and platform could improve the space station scientific and applicative capabilities. The space elevator presents unique characteristics as microgravity facility and as a tethered platform servicing vehicle. Pointing platforms could represent a new kind of observation facility for large class of payloads. The dynamical, control and technological complexity of these concepts advised demonstrative experiments. The on-going tethered satellite system offers the opportunity to perform such experiments. And feasibility studies are in progress.

  9. Dendritic brushes under theta and poor solvent conditions

    Science.gov (United States)

    Gergidis, Leonidas N.; Kalogirou, Andreas; Charalambopoulos, Antonios; Vlahos, Costas

    2013-07-01

    The effects of solvent quality on the internal stratification of polymer brushes formed by dendron polymers up to third generation were studied by means of molecular dynamics simulations with Langevin thermostat. The distributions of polymer units, of the free ends, the radii of gyration, and the back folding probabilities of the dendritic spacers were studied at the macroscopic states of theta and poor solvent. For high grafting densities we observed a small decrease in the height of the brush as the solvent quality decreases. The internal stratification in theta solvent was similar to the one we found in good solvent, with two and in some cases three kinds of populations containing short dendrons with weakly extended spacers, intermediate-height dendrons, and tall dendrons with highly stretched spacers. The differences increase as the grafting density decreases and single dendron populations were evident in theta and poor solvent. In poor solvent at low grafting densities, solvent micelles, polymeric pinned lamellae, spherical and single chain collapsed micelles were observed. The scaling dependence of the height of the dendritic brush at high density brushes for both solvents was found to be in agreement with existing analytical results.

  10. Galectin-4 and small intestinal brush border enzymes form clusters

    DEFF Research Database (Denmark)

    Danielsen, E M; van Deurs, B

    1997-01-01

    that galectin-4 is indeed an intestinal brush border protein; we also localized galectin-4 throughout the cell, mainly associated with membraneous structures, including small vesicles, and to the rootlets of microvillar actin filaments. This was confirmed by subcellular fractionation, showing about half...... by a nonclassical pathway, and the brush border enzymes represent a novel class of natural ligands for a member of the galectin family. Newly synthesized galectin-4 is rapidly "trapped" by association with intracellular structures prior to its apical secretion, but once externalized, association with brush border......Detergent-insoluble complexes prepared from pig small intestine are highly enriched in several transmembrane brush border enzymes including aminopeptidase N and sucrase-isomaltase, indicating that they reside in a glycolipid-rich environment in vivo. In the present work galectin-4, an animal lectin...

  11. Experience of racism and tooth brushing among pregnant Aboriginal Australians: exploring psychosocial mediators.

    Science.gov (United States)

    Ben, J; Jamieson, L M; Priest, N; Parker, E J; Roberts-Thomson, K F; Lawrence, H P; Broughton, J; Paradies, Y

    2014-09-01

    Despite burgeoning evidence regarding the pathways by which experiences of racism influence health outcomes, little attention has been paid to the relationship between racism and oral health-related behaviours in particular. We hypothesised that self-reported racism was associated with tooth brushing, and that this association was mediated by perceived stress and sense of control and moderated by social support. Data from 365 pregnant Aboriginal Australian women were used to evaluate tooth brushing behaviour, sociodemographic factors, psychosocial factors, general health, risk behaviours and racism exposure. Bivariate associations were explored and hierarchical logistic regression models estimated odds ratios (OR) and 95% confidence intervals (CI) for tooth brushing. Perceived stress and sense of control were examined as mediators of the association between self-reported racism and tooth brushing using binary mediation with bootstrapping. High levels of self-reported racism persisted as a risk indicator for tooth brushing (OR 0.51, 95%CI 0.27,0.98) after controlling for significant covariates. Perceived stress mediated the relationship between self-reported racism and tooth brushing: the direct effect of racism on tooth brushing was attenuated, and the indirect effect on tooth brushing was significant (beta coefficient -0.09; bias-corrected 95%CI -0.166,-0.028; 48.1% of effect mediated). Sense of control was insignificant as a mediator of the relationship between racism and tooth brushing. High levels of self-reported racism were associated with non-optimal tooth brushing behaviours, and perceived stress mediated this association among this sample of pregnant Aboriginal women.. Limitations and implications are discussed.

  12. Forces, energetics, and dynamics of conjugated-carbon ring tethers adhered to CNTs: a computational investigation.

    Science.gov (United States)

    Filla, Nicholas; Ramasamy, Ramaraja; Wang, Xianqiao

    2018-04-25

    The strength and nature of the interactions between carbon nanotubes (CNTs) and molecular tethers plays a vital role in technology such as CNT-enzyme sensors. Tethers that attach noncovalently to CNTs are ideal for retaining the electrical properties of the CNTs since they do not degrade the CNT surface and effect its electrical conductivity. However, leaching due to weak CNT-tether attachment is very common when using noncovalent tethers, and this has limited their use in commercial products including biosensors. Thus, understanding the fundamental mechanics governing the strength of CNT-tether adhesion is crucial for the design of highly sensitive, viable sensors. Here, we computationally investigate the adhesion strength of CNT-tether complexes with 8 different tethering molecules designed to adhere noncovalently to the CNT surface. We study the effects of CNT diameter, CNT chirality, and the size/geometry of the tethering molecule on the adhesion energy and force. Our results show an asymptotic relationship between adhesion strength and CNT diameter. Calculations show that noncovalent tethers tested here can reach adhesion forces and energies that are up to 21% and 54% of the strength of the carbon-carbon single bond force and bond energy respectively. We anticipate our results will help guide CNT-enzyme sensor design to produce sensors with high sensitivity and minimal leaching.

  13. Novel roaming and stationary tethered aerial robots for continuous mobile missions in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Beom W.; Choi, Su Y.; Rim, Chun T. [Dept. of Nuclear and Quantum Engineering, KAIST, Daejeon (Korea, Republic of); Choi, Young Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cai, Guowei; Seneviratne, Lakmal [Dept. of Aerospace Engineering, Khalifa University, Abu Dhabi (United Arab Emirates)

    2016-08-15

    In this paper, new tethered aerial robots including roaming tethered aerial robots (RTARs) for radioactive material sampling and stationary tethered aerial robots (STARs) for environment monitoring are proposed to meet extremely-long-endurance missions of nuclear power plants. The flight of the proposed tethered aerial robots may last for a few days or even a few months as long as the tethered cable provides continuous power. A high voltage AC or DC power system was newly adopted to reduce the mass of the tethered cable. The RTAR uses a tethered cable spooled from the aerial robot and an aerial tension control system. The aerial tension control system provides the appropriate tension to the tethered cable, which is accordingly laid down on the ground as the RTAR roams. The STAR includes a tethered cable spooled from the ground and a ground tension control system, which enables the STAR to reach high altitudes. Prototypes of the RTAR and STAR were designed and successfully demonstrated in outdoor environments, where the load power, power type, operating frequency, and flight attitude of the RTAR and STAR were: 180 W, AC 100 kHz, and 20 m; and 300 W, AC or DC 100 kHz, and 80 m, respectively.

  14. Novel Roaming and Stationary Tethered Aerial Robots for Continuous Mobile Missions in Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Beom W. Gu

    2016-08-01

    Full Text Available In this paper, new tethered aerial robots including roaming tethered aerial robots (RTARs for radioactive material sampling and stationary tethered aerial robots (STARs for environment monitoring are proposed to meet extremely-long-endurance missions of nuclear power plants. The flight of the proposed tethered aerial robots may last for a few days or even a few months as long as the tethered cable provides continuous power. A high voltage AC or DC power system was newly adopted to reduce the mass of the tethered cable. The RTAR uses a tethered cable spooled from the aerial robot and an aerial tension control system. The aerial tension control system provides the appropriate tension to the tethered cable, which is accordingly laid down on the ground as the RTAR roams. The STAR includes a tethered cable spooled from the ground and a ground tension control system, which enables the STAR to reach high altitudes. Prototypes of the RTAR and STAR were designed and successfully demonstrated in outdoor environments, where the load power, power type, operating frequency, and flight attitude of the RTAR and STAR were: 180 W, AC 100 kHz, and 20 m; and 300 W, AC or DC 100 kHz, and 80 m, respectively.

  15. Brushes and soap : grafted polymers and their interactions with nanocolloids

    OpenAIRE

    Currie, E.P.K.

    2000-01-01

    Layers of polymer chains end-attached to a grafting plane at high densities, so-called brushes, are a curious state of matter. The (average) monomer density within the brush is as high as in a semi-dilute polymer solution, resulting in a high osmotic pressure in the brush. Due to the grafting, however, this isotropic osmotic pressure results in an anisotropic stretching of the chains normal to the surface. This degree of stretching can be quite extensive; in this thesis PEO-chains of...

  16. Current control by a homopolar machine with moving brushes

    International Nuclear Information System (INIS)

    Vogel, H.

    1978-01-01

    The equation for TNS Doublet's E-coil circuit with moving brush homopolar machine is integrated in the flux of the homopolar for a monotonically increasing current function extending beyond the current reversal into the burn period. The results show that the moving brush feature is not useful for controlling the burn

  17. The Effects of a Brushing Procedure on Stereotypical Behavior

    Science.gov (United States)

    Davis, Tonya N.; Durand, Shannon; Chan, Jeffrey M.

    2011-01-01

    In this study we analyzed the effects of a brushing protocol on stereotyped behavior of a young boy with autism. First, a functional analysis was conducted which showed that the participant's stereotypy was maintained by automatic reinforcement. Next, the Wilbarger Protocol, a brushing intervention, was implemented. An ABA design was implemented…

  18. Electron Emitter for small-size Electrodynamic Space Tether using MEMS Technology

    DEFF Research Database (Denmark)

    Fleron, René A. W.; Blanke, Mogens

    2004-01-01

    Adjustment of the orbit of a spacecraft using the forces created by an electro-dynamic space-tether has been shown as a theoretic possibility in recent literature. Practical implementation is being pursued for larger scale missions where a hot filament device controls electron emission...... and the current flowing in the electrodynamic space tether. Applications to small spacecraft, or space debris in the 1–10 kg range, possess difficulties with electron emission technology, as low power emitting devices are needed. This paper addresses the system concepts of a small spacecraft electrodynamic tether...... system with focus on electron emitter design and manufacture using micro-electro-mechanical- system (MEMS) technology. The paper addresses the system concepts of a small size electrodynamic tether mission and shows a novel electron emitter for the 1-2 mA range where altitude can be effectively affected...

  19. Effects of Bristle Hardness & Duration of Manual Tooth brushing on Plaque Control

    Directory of Open Access Journals (Sweden)

    . Sunny

    2017-03-01

    Full Text Available Background: Oral health is an integral part of general health. Poor oral health can have adverse effect on general health hence a good oral health is very essential, which in turn is achieved by good oral hygiene. Even though, the concept of good oral hygiene evolved 5000 years back, it is only in the beginning of 19th century it gained more importance. (1 Dental caries and periodontal disease are the most commonly occurring diseases affecting mankind. Dental plaque is a very important factor in the causation of both the diseases. (2 Aims & Objectives: To evaluate efficacy of four different types of toothbrushes, with difference in duration of brushing along with different bristle hardness in removal of microbial plaque. Material & Methods: In a randomized controlled trial, four groups with 40 subjects used manual toothbrushes with either hard, medium, soft and ultra-soft bristles. On baseline examination, clinical parameter plaque index (Sillness & Loe, 1964 was recorded. Selected subjects were refrained from all kinds of oral hygiene measures for 24 hrs before clinical appointment. On the day of clinical appointment scores of pre and post brushing were recorded in each patient when brushing time was set for 1 minute and same procedure was repeated after a wash off period of 3 days and similar recordings were made with brushing time of 11/2minute. Primary outcome was measured with differences in the plaque index (Sillness & Loe, 1964 compared to baseline. Results: Significant reduction in mean value of plaque score was observed on comparing pre-brushing and post-brushing data in all the subjects irrespective of bristle hardness in both 1 minute and 11/2 minute groups. On increasing time duration from 1 minute to 11/2 minute intergroup comparison revealed that significant correlation exist in mean plaque score reduction in subjects using medium bristle brush, soft bristle brush, ultra-soft bristle brush. However, no significant reduction in

  20. Results from a tethered rocket experiment (Charge-2)

    Science.gov (United States)

    Kawashima, N.; Sasaki, S.; Oyama, K. I.; Hirao, K.; Obayashi, T.; Raitt, W. J.; White, A. B.; Williamson, P. R.; Banks, P. M.; Sharp, W. F.

    A tethered payload experiment (Charge-2) was carried out as an international program between Japan and the USA using a NASA sounding rocket at White Sands Missile Range. The objective of the experiment was to perform a new type of active experiment in space by injecting an electron beam from a mother-daughter rocket system connected with a long tether wire. The electron beam with voltage and current up to 1 kV and 80 mA (nominal) was injected from the mother payload. An insulated conductive wire of 426 m length connected the two payloads, the longest tether system flown so far. The electron gun system and diagnostic instruments (plasma, optical, particle and wave) functioned correctly throughout the flight. The potential rise of the mother payload during the electron beam emission was measured with respect to the daughter payload. The beam trajectory was detected by a camera onboard the mother rocket. Wave generation and current induction in the wire during the beam emission were also studied.

  1. Trends in Social Inequality in Tooth Brushing among Adolescents: 1991-2014

    DEFF Research Database (Denmark)

    Holstein, Bjørn Evald; Bast, Lotus Sofie; Brixval, Carina Sjöberg

    2015-01-01

    This study examines whether social inequality in tooth brushing frequency among adolescents changed from 1991 to 2014. The data material was seven comparable cross-sectional studies of nationally representative samples of 11- to 15-year-olds in Denmark with data about frequency of tooth brushing...... and occupation of parents. The total number of participants was 31,464, of whom 21.7% brushed their teeth less than the recommended 2 times a day. The absolute social inequality measured as prevalence difference between low and high social class increased from 7.7% in 1991 to 14.6% in 2014. The relative social...... inequality assessed by odds ratios for infrequent tooth brushing also increased from 1991 to 2014....

  2. Synergy of brushing mode and antibacterial use on in vivo biofilm formation.

    Science.gov (United States)

    Jongsma, Marije A; van de Lagemaat, Marieke; Busscher, Henk J; Geertsema-Doornbusch, Gesinda I; Atema-Smit, Jelly; van der Mei, Henny C; Ren, Yijin

    2015-12-01

    Orthodontic, multi-strand retention-wires are used as a generalized model for oral retention sites to investigate whether biofilm left-behind after powered toothbrushing in-vivo enabled better penetration of antibacterials as compared with manual brushing. 2-cm multi-strand, stainless-steel retention-wires were placed in brackets bonded bilaterally in the upper arches of 10-volunteers. Volunteers used NaF-sodium-lauryl-sulphate-containing toothpaste and antibacterial, triclosan-containing toothpaste supplemented or not with an essential-oils containing mouthrinse. Opposite sides of the dentition including the retention-wires, were brushed manually or with a powered toothbrush. Health-care-regimens were maintained for 1-week, after which wires were removed and oral biofilm was collected. When powered toothbrushing was applied, slightly less bacteria were collected than after manual brushing, regardless whether an antibacterial-regimen was used or not. Powered-toothbrushing combined with antibacterial-regimens yielded lower biofilm viability than manual brushing, indicating better antibacterial penetration into biofilm left-behind after powered brushing. Major shifts in biofilm composition, with a decrease in prevalence of both cariogenic species and periodontopathogens, were induced after powered brushing using an antibacterial-regimen. Oral biofilm left-behind after powered brushing in-vivo enabled better penetration of antibacterials than after manual brushing. Mechanical removal of oral biofilm is important for prevention of dental pathologies, but biofilm is always left-behind, such as in fissures, buccal pits, interproximal areas and gingival margins and around orthodontic appliances. Use of antibacterial toothpastes or mouthrinses can contribute to removal or killing of biofilm bacteria, but biofilm structure hampers antibacterial penetration. A synergy between brushing mode and antibacterial-regimen applied exists with clinically demonstrable effects

  3. Gingival abrasion and recession in manual and oscillating-rotating power brush users.

    Science.gov (United States)

    Rosema, N A M; Adam, R; Grender, J M; Van der Sluijs, E; Supranoto, S C; Van der Weijden, G A

    2014-11-01

    To assess gingival recession (GR) in manual and power toothbrush users and evaluate the relationship between GR and gingival abrasion scores (GA). This was an observational (cross-sectional), single-centre, examiner-blind study involving a single-brushing exercise, with 181 young adult participants: 90 manual brush users and 91 oscillating-rotating power brush users. Participants were assessed for GR and GA as primary response variables. Secondary response variables were the level of gingival inflammation, plaque score reduction and brushing duration. Pearson correlation was used to describe the relationship between number of recession sites and number of abrasions. Prebrushing (baseline) and post-brushing GA and plaque scores were assessed and differences analysed using paired tests. Two-sample t-test was used to analyse group differences; ancova was used for analyses of post-brushing changes with baseline as covariate. Overall, 97.8% of the study population had at least one site of ≥1 mm of gingival recession. For the manual group, this percentage was 98.9%, and for the power group, this percentage was 96.7% (P = 0.621). Post-brushing, the power group showed a significantly smaller GA increase than the manual group (P = 0.004); however, there was no significant correlation between number of recession sites and number of abrasions for either group (P ≥ 0.327). Little gingival recession was observed in either toothbrush user group; the observed GR levels were comparable. Lower post-brushing gingival abrasion levels were seen in the power group. There was no correlation between gingival abrasion as a result of brushing and the observed gingival recession following use of either toothbrush. © 2014 The Authors International Journal of Dental Hygiene Published by John Wiley & Sons Ltd.

  4. Plaque-left-behind after brushing: intra-oral reservoir for antibacterial toothpaste ingredients.

    Science.gov (United States)

    Otten, Marieke P T; Busscher, Henk J; Abbas, Frank; van der Mei, Henny C; van Hoogmoed, Chris G

    2012-10-01

    Plaque is never fully removed by brushing and may act as a reservoir for antibacterial ingredients, contributing to their substantive action. This study investigates the contribution of plaque-left-behind and saliva towards substantivity of three antibacterial toothpastes versus a control paste without antibacterial claims. First, volunteers brushed 2 weeks with a control or antibacterial toothpaste. Next, plaque and saliva samples were collected 6 and 12 h after brushing and bacterial concentrations and viabilities were measured. The contributions of plaque and saliva towards substantivity were determined by combining control plaques with experimental plaque or saliva samples and subsequently assessing their viabilities. Bacterial compositions in the various plaque and saliva samples were compared using denaturing gradient gel electrophoresis. The viabilities of plaques after brushing with Colgate-Total® and Crest-Pro-Health® were smaller than of control plaques and up to 12 h after brushing with Crest-Pro-Health® plaques still contained effective, residual antibacterial activity against control plaques. No effective, residual antibacterial activity could be measured in saliva samples after brushing. There was no significant difference in bacterial composition of plaque or saliva after brushing with the different toothpastes. Plaque-left-behind after mechanical cleaning contributes to the substantive action of an antibacterial toothpaste containing stannous fluoride (Crest-Pro-Health®). The absorptive capacity of plaque-left-behind after brushing is of utmost clinical importance, since plaque is predominantly left behind in places where its removal and effective killing matter most. Therewith this study demonstrates a clear and new beneficial effect of the use of antibacterial toothpastes.

  5. Evaluation of brushing cytology in the diagnosis of Helicobacter pylori gastritis

    Directory of Open Access Journals (Sweden)

    Amir Ahmad Mostaghni

    2008-02-01

    Full Text Available Background: Helicobacter pylori (HP is the cause of the most common infection in the world. It has been recognized as the major cause of peptic ulcer and an important risk factor for gastric malignancy. A variety of reliable methods are available for detecting HP during upper gastrointestinal endoscopy. Rapid urease test (RUT is the cheapest method and histology is the most expensive brush cytology is faster and cheaper than histology. Methods: The brushing cytology materials were obtained from the antrum of the stomach in 109 patients who suffered from dyspepsia and were candidates for endoscopy. The RUT and histology with hematoxylin-eosin staining were also performed on each patient separately. The infection status for each patient was established by a concordance of two test results. Results: Seventy-eight of 100 patients (78% were diagnosed as positive for Helicobacter pylori organisms using brushing cytology. The sensitivity and specificity of brushing cytology were 96% and 72% respectively. Sensitivity of brush cytology (96% was higher than RUT (77.4%, and RUT was more specific than histology (100% vs 90%. Conclusion: Gastric brushing cytology provides an accurate, inexpensive and easy technique in the rapid detection of Helicobacter pylori infection. When additional information about the severity of mucosal damage or the presence of cell atypias is not necessary, histologic examination can be omitted, and a cost effective strategy for assessing HP status might consist of taking antral biopsies, the former for RUT and performing brush cytology slide, which should be stained and examined only when the RUT result is negative.

  6. Microsecond MD Simulations of Nano-patterned Polymer Brushes on Self-Assembled Monolayers

    Science.gov (United States)

    Buie, Creighton; Qiu, Liming; Cheng, Kwan; Park, Soyeun

    2010-03-01

    Nano-patterned polymer brushes end-grafted onto self-assembled monolayers have gained increasing research interests due to their unique thermodynamic properties and their chemical and biomedical applications in colloids, biosensing and tissue engineering. So far, the interactions between the polymer brushes with the surrounding environments such as the floor and solvent at the nanometer length scale and microsecond time scale are still difficult to obtained experimentally and computationally. Using a Coarse-Grained MD approach, polymer brushes of different monomeric lengths, grafting density and hydrophobicity of the monomers grafted on self-assembled monolayers and in explicit solvent were studied. Molecular level information, such as lateral diffusion, transverse height and volume contour of the brushes, were calculated from our microsecond-MD simulations. Our results demonstrated the significance of the hydration of the polymer in controlling the conformational arrangement of the polymer brushes.

  7. Long-term evaluation of intraoperative neurophysiological monitoring-assisted tethered cord surgery

    NARCIS (Netherlands)

    Dulfer, S E; Drost, G; Lange, F; Journee, H L; Wapstra, F H; Hoving, E W

    2017-01-01

    PURPOSE: Patients with tethered spinal cord have been investigated for short-term effects after tethered spinal cord surgery in the past. However, little is known about the long-term effects in this patient group. In this retrospective, longitudinal, observational study, a patient sample of a

  8. Self-assembled tethered bimolecular lipid membranes.

    Science.gov (United States)

    Sinner, Eva-Kathrin; Ritz, Sandra; Naumann, Renate; Schiller, Stefan; Knoll, Wolfgang

    2009-01-01

    This chapter describes some of the strategies developed in our group for designing, constructing and structurally and functionally characterizing tethered bimolecular lipid membranes (tBLM). We introduce this platform as a novel model membrane system that complements the existing ones, for example, Langmuir monolayers, vesicular liposomal dispersions and bimolecular ("black") lipid membranes. Moreover, it offers the additional advantage of allowing for studies of the influence of membrane structure and order on the function of integral proteins, for example, on how the composition and organization of lipids in a mixed membrane influence the ion translocation activity of integral channel proteins. The first strategy that we introduce concerns the preparation of tethered monolayers by the self-assembly of telechelics. Their molecular architecture with a headgroup, a spacer unit (the "tether") and the amphiphile that mimics the lipid molecule allows them to bind specifically to the solid support thus forming the proximal layer of the final architecture. After fusion of vesicles that could contain reconstituted proteins from a liposomal dispersion in contact to this monolayer the tethered bimolecular lipid membrane is obtained. This can then be characterized by a broad range of surface analytical techniques, including surface plasmon spectroscopies, the quartz crystal microbalance, fluorescence and IR spectroscopies, and electrochemical techniques, to mention a few. It is shown that this concept allows for the construction of tethered lipid bilayers with outstanding electrical properties including resistivities in excess of 10 MOmega cm2. A modified strategy uses the assembly of peptides as spacers that couple covalently via their engineered sulfhydryl or lipoic acid groups at the N-terminus to the employed gold substrate, while their C-terminus is being activated afterward for the coupling of, for example, dimyristoylphosphatidylethanol amine (DMPE) lipid molecules

  9. Evaluation of multi-brush anode systems in microbial fuel cells

    KAUST Repository

    Lanas, Vanessa; Logan, Bruce E.

    2013-01-01

    ), the number of brushes connected in parallel, and the wire current collector gage. MFCs with different numbers of brushes (one, three or six) set perpendicular to the cathode all produced similar power densities (1200±40mW/m2) and coulombic efficiencies (60

  10. Molecular Design of Antifouling Polymer Brushes Using Sequence-Specific Peptoids.

    Science.gov (United States)

    Lau, King Hang Aaron; Sileika, Tadas S; Park, Sung Hyun; Sousa, Ana Maria Leal; Burch, Patrick; Szleifer, Igal; Messersmith, Phillip B

    2015-01-07

    Material systems that can be used to flexibly and precisely define the chemical nature and molecular arrangement of a surface would be invaluable for the control of complex biointerfacial interactions. For example, progress in antifouling polymer biointerfaces that prevent non-specific protein adsorption and cell attachment, which can significantly improve the performance of an array of biomedical and industrial applications, is hampered by a lack of chemical models to identify the molecular features conferring their properties. Poly(N-substituted glycine) "peptoids" are peptidomimetic polymers that can be conveniently synthesized with specific monomer sequences and chain lengths, and are presented as a versatile platform for investigating the molecular design of antifouling polymer brushes. Zwitterionic antifouling polymer brushes have captured significant recent attention, and a targeted library of zwitterionic peptoid brushes with a different charge densities, hydration, separations between charged groups, chain lengths, and grafted chain densities, is quantitatively evaluated for their antifouling properties through a range of protein adsorption and cell attachment assays. Specific zwitterionic brush designs were found to give rise to distinct but subtle differences in properties. The results also point to the dominant roles of the grafted chain density and chain length in determining the performance of antifouling polymer brushes.

  11. Minimum free-energy paths for the self-organization of polymer brushes.

    Science.gov (United States)

    Gleria, Ignacio; Mocskos, Esteban; Tagliazucchi, Mario

    2017-03-22

    A methodology to calculate minimum free-energy paths based on the combination of a molecular theory and the improved string method is introduced and applied to study the self-organization of polymer brushes under poor solvent conditions. Polymer brushes in a poor solvent cannot undergo macroscopic phase separation due to the physical constraint imposed by the grafting points; therefore, they microphase separate forming aggregates. Under some conditions, the theory predicts that the homogeneous brush and the aggregates can exist as two different minima of the free energy. The theoretical methodology introduced in this work allows us to predict the minimum free-energy path connecting these two minima as well as the morphology of the system along the path. It is shown that the transition between the homogeneous brush and the aggregates may involve a free-energy barrier or be barrierless depending on the relative stability of the two morphologies and the chain length and grafting density of the polymer. In the case where a free-energy barrier exists, one of the morphologies is a metastable structure and, therefore, the properties of the brush as the quality of the solvent is cycled are expected to display hysteresis. The theory is also applied to study the adhesion/deadhesion transition between two opposing surfaces modified by identical polymer brushes and it is shown that this process may also require surpassing a free-energy barrier.

  12. Two-Way Tether Gun

    Science.gov (United States)

    Sanger, George F.

    1994-01-01

    Safety-tether device enables crewmembers on spacecraft to retrieve crewmember drifting away from spacecraft. Alternatively, drifting crewmember who carries device uses it to grasp and return to spacecraft. Also used on Earth. For example, rescuer on vessel or pier uses it to retrieve and haul drowning or unconscious person to safety; drifting person or rescuer in water uses it to grasp and hold onto support.

  13. Sweet brushes and dirty proteins

    NARCIS (Netherlands)

    Bosker, Wouter T. E.; Patzsch, Katja; Stuart, Martien A. Cohen; Norde, Willem

    2007-01-01

    We studied the protein repellency of dextran brushes. Dextran was grafted to a polystyrene surface in a broad range of grafting densities using polystyrene - dextran block copolymers and the Langmuir - Blodgett deposition technique. Ellipsometry measurements confirmed a successful transfer of the

  14. Investigation of electrodynamic stabilization and control of long orbiting tethers. [space shuttle payloads

    Science.gov (United States)

    Arnold, D. A.; Dobrowolny, M.

    1981-01-01

    An algorithm for using electric currents to control pendular oscillations induced by various perturbing forces on the Skyhook wire is considered. Transverse and vertical forces on the tether; tether instability modes and causes during retrieval by space shuttle; simple and spherical pendulum motion and vector damping; and current generation and control are discussed. A computer program for numerical integration of the in-plane and out-of-plane displacements of the tether vs time was developed for heuristic study. Some techniques for controlling instabilities during payload retrieval and methods for employing the tether for launching satellites from the space shuttle are considered. Derivations and analyses of a general nature used in all of the areas studied are included.

  15. 46 CFR 108.187 - Ventilation for brush type electric motors in classified spaces.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation for brush type electric motors in classified... Ventilation for brush type electric motors in classified spaces. Ventilation for brush type electric motors in... Electrical Equipment in Hazardous Locations”, except audible and visual alarms may be used if shutting down...

  16. Dimeric assembly of enterocyte brush border enzymes

    DEFF Research Database (Denmark)

    Danielsen, E M

    1994-01-01

    The noncovalent, dimeric assembly of small intestinal brush border enzymes was studied by sedimentation analysis in density gradients of extracts of pulse-labeled pig jejunal mucosal explants. Like aminopeptidase N (EC 3.4.11.2), sucrase-isomaltase (EC 3.2.1.48-10), aminopeptidase A (EC 3...... appearance of the liposome-reconstituted enzyme [Norén et al. (1986) J. Biol. Chem. 261, 12306-12309], showing only the inner, membrane-anchored domains of the monomers to be in close contact with one another while the outer domains are far apart. In contrast to the other brush border enzymes studied...

  17. Position Control of an X4-Flyer Using a Tether

    Directory of Open Access Journals (Sweden)

    , Keigo Watanabe

    2014-10-01

    Full Text Available In Japan, aging of infrastructures, such as roads, bridges, and water and sewer services, etc. poses a problem, and it is required to extend the life-span of such infrastructures by maintenance. Among infrastructures, especially bridges are periodically inspected by short range visual observations, which check the damage and deterioration of the surface. However, since there are some cases where the short range visual observation is difficult, an alternative method is required so as to replace the short range visual observation with it. So, "X4-Flyer" is very attractive because of realizing a movement at high altitude easily. The objective of this study is to develop a tethered X4- Flyer, so that the conventional short range visual observation of bridges is replaced by it. In this paper, a method for the measurement and control of the position is described by using a tether for controlling the position of the X4-Flyer. In addition, it is checked whether the tethered X4-Flyer can control the position using the proposed method or not, letting it fly in a state in which a tether is being attached.

  18. Vision, healing brush, and fiber bundles

    Science.gov (United States)

    Georgiev, Todor

    2005-03-01

    The Healing Brush is a tool introduced for the first time in Adobe Photoshop (2002) that removes defects in images by seamless cloning (gradient domain fusion). The Healing Brush algorithms are built on a new mathematical approach that uses Fibre Bundles and Connections to model the representation of images in the visual system. Our mathematical results are derived from first principles of human vision, related to adaptation transforms of von Kries type and Retinex theory. In this paper we present the new result of Healing in arbitrary color space. In addition to supporting image repair and seamless cloning, our approach also produces the exact solution to the problem of high dynamic range compression of17 and can be applied to other image processing algorithms.

  19. A novel approach for UV-patterning with binary polymer brushes.

    Science.gov (United States)

    Li, Lifu; Nakaji-Hirabayashi, Tadashi; Kitano, Hiromi; Ohno, Kohji; Saruwatari, Yoshiyuki; Matsuoka, Kazuyoshi

    2018-01-01

    A mixed self-assembled monolayer (SAM) of an initiator (3-(2-bromo-2-isobutyryloxy)propyl triethoxysilane) for atom transfer radical polymerization (ATRP) and an agent (6-(triethoxysilyl)hexyl 2-(((methylthio)carbonothioyl)thio)-2-phenylacetate) for reversible addition-fragmentation chain transfer (RAFT) polymerization was constructed on the surface of a silicon wafer or glass plate by a silane coupling reaction. When a UV light at 254nm was irradiated at the mixed SAM through a photomask, the surface density of the bromine atom at the end of BPE in the irradiated region was drastically reduced by UV-driven scission of the BrC bond, as observed by X-ray photoelectron spectroscopy. Consequently, the surface-initiated (SI)-ATRP of 2-ethylhexyl methacrylate (EHMA) was used to easily construct the poly(EHMA) (PEHMA) brush domain. Subsequently, SI-RAFT polymerization of a zwitterionic vinyl monomer, carboxymethyl betaine (CMB), was performed. Using the sequential polymerization, the PCMB and PEHMA brush domains on the solid substrate could be very easily patterned. Patterning proteins and cells with the binary polymer brush is expected because the PCMB brush indicated strong suppression of protein adsorption and cell adhesion, and the PEHMA brush had non-polar properties. This technique is very simple and useful for regulating the shape and size of bio-fouling and anti-biofouling domains on solid surfaces. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Synthesis and insertion chemistry of mixed tether uranium metallocene complexes

    Energy Technology Data Exchange (ETDEWEB)

    Siladke, Nathan A.; LeDuc, Jennifer; Ziller, Joseph W.; Evans, William J. [Department of Chemistry, University of California, Irvine, CA (United States)

    2012-11-12

    The synthesis of mixed tethered alkyl uranium metallocenes has been investigated by examining the reactivity of the bis(tethered alkyl) metallocene [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC){sub 2}U] (1) with substrates that react with only one of the U-C linkages. The effect of these mixed tether coordination environments on the reactivity of the remaining U-C bond has been studied by using CO insertion chemistry. One equivalent of azidoadamantane (AdN{sub 3}) reacts with 1 to yield the mixed tethered alkyl triazenido complex [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC)U(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}-CH{sub 2}NNN-Ad-κ{sup 2}N{sup 1,3})]. Similarly, a single equivalent of CS{sub 2} reacts with 1 to form the mixed tethered alkyl dithiocarboxylate complex [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC)U(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}- CH{sub 2}C(S){sub 2}-κ{sup 2}S,S{sup '})], a reaction that constitutes the first example of CS{sub 2} insertion into a U{sup 4+}-C bond. Complex 1 reacts with one equivalent of pyridine N-oxide by C-H bond activation of the pyridine ring to form a mixed tethered alkyl cyclometalated pyridine N-oxide complex [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC)(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 3})U(C{sub 6}H{sub 4}NO-κ{sup 2} C,O)]. The remaining (η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC){sup 2-} ligand in each of these mixed tethered species show reactivity towards CO and tethered enolate ligands form by insertion. Subsequent rearrangement have been identified in [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 3})U(C{sub 5}H{sub 4}NO-κ{sup 2}C,O)(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}C(=CH{sub 2})O- κO)] and [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}NNN-Ad-κ{sup 2}N{sup 1,3})U(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}C(=CH{sub 2})O-κO)]. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Simulations of momentum transfer process between solar wind plasma and bias voltage tethers of electric sail thruster

    Science.gov (United States)

    Xia, Guangqing; Han, Yajie; Chen, Liuwei; Wei, Yanming; Yu, Yang; Chen, Maolin

    2018-06-01

    The interaction between the solar wind plasma and the bias voltage of long tethers is the basic mechanism of the electric sail thruster. The momentum transfer process between the solar wind plasma and electric tethers was investigated using a 2D full particle PIC method. The coupled electric field distribution and deflected ion trajectory under different bias voltages were compared, and the influence of bias voltage on momentum transfer process was analyzed. The results show that the high potential of the bias voltage of long tethers will slow down, stagnate, reflect and deflect a large number of ions, so that ion cavities are formed in the vicinity of the tether, and the ions will transmit the axial momentum to the sail tethers to produce the thrust. Compared to the singe tether, double tethers show a better thrust performance.

  2. Probing endocytosis from the enterocyte brush border using fluorescent lipophilic dyes

    DEFF Research Database (Denmark)

    Danielsen, E Michael

    2015-01-01

    The small intestinal brush border is a specialized cell membrane that needs to withstand the solubilizing effect of bile salts during assimilation of dietary nutrients and to achieve detergent resistance; it is highly enriched in glycolipids organized in lipid raft microdomains. In the present work......-toluenesulfonate), and CellMask Orange plasma membrane stain were used to study endocytosis from the enterocyte brush border of organ-cultured porcine mucosal explants. All the dyes readily incorporated into the brush border but were not detectably endocytosed by 5 min, indicating a slow uptake compared with other cell types...

  3. Comparison of Three types of Tooth Brushes on Plaque and Gingival Indices: A Randomized Clinical Trial.

    Science.gov (United States)

    Moeintaghavi, Amir; Sargolzaie, Naser; Rostampour, Mehrnoosh; Sarvari, Sara; Kargozar, Sanaz; Gharaei, Shideh

    2017-01-01

    To compare clinical results of three types of manual tooth brushes on plaque removal efficacy and gingivitis. This study is a single blind randomized trial with crossover design which involved 30 periodontaly healthy individuals. Professional plaque removal and oral hygiene instruction were performed for all the participants in the first step of our study followed by asking them to avoid brushing for 2 days. Thereafter plaque and gingivitis scores were measured using plaque and gingival indices (PI and GI). Then subjects were instructed to use Pulsar tooth brush for a two-week period and then, GI and PI indices were assessed again. After passing one-week period for wash out, subjects didn't brush for 2 days and indices were recorded again. The same procedure was done for CrossAction, and Butler 411 tooth brushes respectively and at the end of the study these variables were analyzed using SPSS software ver.16. Repeated measurement ANOVA test was used to compare the scores between different brushes. Finding of this study reveals that using all three types of tooth brushes resulted in significant plaque and gingivitis reduction compared to baseline levels. Pulsar tooth brush was significantly more effective in diminishing PI and GI than Butler tooth brush (p=0.044 and 0.031 respectively). According to our findings all 3 types of tooth brushes are effective in reduction of plaque and gingivitis and this reduction is significantly greater for Pulsar tooth brush compared to Butler and CrossAction tooth brushes.

  4. Low Earth Orbit Environmental Effects on Space Tether Materials

    Science.gov (United States)

    Finckernor, Miria M.; Gitlemeier, Keith A.; Hawk, Clark W.; Watts, Ed

    2005-01-01

    Atomic oxygen (AO) and ultraviolet (UV) radiation erode and embrittle most polymeric materials. This research was designed to test several different materials and coatings under consideration for their application to space tethers, for resistance to these effects. The samples were vacuum dehydrated, weighed and then exposed to various levels of AO or UV radiation at the NASA Marshall Space Flight Center. They were then re-weighed to determine mass loss due to atomic oxygen erosion, inspected for damage and tensile tested to determine strength loss. The experiments determined that the Photosil coating process, while affording some protection, damaged the tether materials worse than the AO exposure. TOR-LM also failed to fully protect the materials, especially from UV radiation. The POSS and nickel coatings did provide some protection to the tethers, which survived the entire test regime. M5 was tested, uncoated, and survived AO exposure, though its brittleness prevented any tensile testing.

  5. Effects of whitening dentifrice on yttria-stabilized tetragonal zirconia polycrystal surfaces after simulating brushing.

    Science.gov (United States)

    Pinelli, Lígia Antunes Pereira; Gimenes Olbera, Amanda Caroline; Candido, Lucas Miguel; Miotto, Larissa Natiele; Antonio, Selma Gutierrez; Fais, Laiza Maria Grassi

    2017-01-01

    The changes that occur after brushing yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) are unknown. These changes may favor the retention of microorganisms and chemisorption of water, impairing its longevity. The purpose of this in vitro study was to evaluate the effects of a whitening dentifrice on Y-TZP surfaces after simulating 10 years of brushing. Seventy-two bar-shaped specimens (20×4×1.2 mm) were divided into 4 groups: storage in distilled water (SW, control), brushing with distilled water (BW), brushing with dentifrice (BD), and brushing with whitening dentifrice (BWD). Brushing was conducted using a linear brushing machine (878400 cycles, 0.98 N, soft toothbrush). The mean roughness (Ra) was analyzed with a profilometer and the superficial topography with scanning electron microscopy (SEM) at baseline and after treatment. Crystalline phases were characterized using x-ray diffraction. Baseline and posttreatment Ra were analyzed using the 1-way ANOVA and Tukey HSD multiple comparison test; the paired t test was used for intragroup comparison (all α=.05). The Ra (μm) means (before/after treatment) were SW 0.28/0.28; BW 0.32/0.31; BD 0.28/0.36; BWD 0.30/0.20. No statistically significant difference was found for Ra at baseline (P=.108) than for posttreatment results (P<.001); the BD group had higher Ra values when compared with baseline (P=.019); the BWD group had the lowest values (P<.001). The BD surfaces showed pronounced scratches and detachment of the surface, while BWD showed smoother surfaces; similar crystallographic results among groups were observed. Brushing Y-TZP with conventional dentifrice increased roughness, while brushing with whitening dentifrice reduced roughness. Neither dentifrice changed the crystallographic phases after brushing. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Unconventional ordering behavior of semi-flexible polymers in dense brushes under compression.

    Science.gov (United States)

    Milchev, Andrey; Binder, Kurt

    2014-06-07

    Using a coarse-grained bead-spring model for semi-flexible macromolecules which form a polymer brush, the structure and dynamics of the polymers were investigated, varying the chain stiffness and the grafting density. The anchoring conditions for the grafted chains were chosen such that their first bonds were oriented along the normal to the substrate plane. The compression of such a semi-flexible brush by a planar piston was observed to be a two-stage process: for a small compression the chains were shown to contract by "buckling" deformation whereas for a larger compression the chains exhibited a collective (almost uniform) bending deformation. Thus, the stiff polymer brush underwent a 2nd order phase transition of collective bond reorientation. The pressure, required to keep the stiff brush at a given degree of compression, was thereby significantly smaller than for an otherwise identical brush made of entirely flexible polymer chains! While both the brush height and the chain linear dimensions in the z-direction perpendicular to the substrate increased monotonically with an increase in the chain stiffness, the lateral (xy) chain linear dimensions exhibited a maximum at an intermediate chain stiffness. Increasing the grafting density led to a strong decrease of these lateral dimensions which is compatible with an exponential decay. Also the recovery kinetics after removal of the compressing piston were studied, and were found to follow a power-law/exponential decay with time. A simple mean-field theoretical consideration, accounting for the buckling/bending behavior of semi-flexible polymer brushes under compression was suggested.

  7. The motion and control of a complex three-body space tethered system

    Science.gov (United States)

    Shi, Gefei; Zhu, Zhanxia; Chen, Shiyu; Yuan, Jianping; Tang, Biwei

    2017-11-01

    This paper is mainly devoted to investigating the dynamics and stability control of a three body-tethered satellite system which contains a main satellite and two subsatellites connected by two straight, massless and inextensible tethers. Firstly, a detailed mathematical model is established in the central gravitational field. Then, the dynamic characteristics of the established system are investigated and analyzed. Based on the dynamic analysis, a novel sliding mode prediction model (SMPM) control strategy is proposed to suppress the motion of the built tethered system. The numerical results show that the proposed underactuated control law is highly effective in suppressing the attitude/libration motion of the underactuated three-body tethered system. Furthermore, cases of different target angles are also examined and analyzed. The simulation results reveal that even if the final equilibrium states differ from different selections of the target angles, the whole system can still be maintained in acceptable areas.

  8. Salt dependence of compression normal forces of quenched polyelectrolyte brushes

    Science.gov (United States)

    Hernandez-Zapata, Ernesto; Tamashiro, Mario N.; Pincus, Philip A.

    2001-03-01

    We obtained mean-field expressions for the compression normal forces between two identical opposing quenched polyelectrolyte brushes in the presence of monovalent salt. The brush elasticity is modeled using the entropy of ideal Gaussian chains, while the entropy of the microions and the electrostatic contribution to the grand potential is obtained by solving the non-linear Poisson-Boltzmann equation for the system in contact with a salt reservoir. For the polyelectrolyte brush we considered both a uniformly charged slab as well as an inhomogeneous charge profile obtained using a self-consistent field theory. Using the Derjaguin approximation, we related the planar-geometry results to the realistic two-crossed cylinders experimental set up. Theoretical predictions are compared to experimental measurements(Marc Balastre's abstract, APS March 2001 Meeting.) of the salt dependence of the compression normal forces between two quenched polyelectrolyte brushes formed by the adsorption of diblock copolymers poly(tert-butyl styrene)-sodium poly(styrene sulfonate) [PtBs/NaPSS] onto an octadecyltriethoxysilane (OTE) hydrophobically modified mica, as well as onto bare mica.

  9. Nanostructure of Cationic Polymer Brush at the Air/Water Interface

    Directory of Open Access Journals (Sweden)

    Matsuoka Hideki

    2013-08-01

    Full Text Available Cationic amphiphilic diblock copolymers were synthesized by RAFT polymerization and the nanostructure of their monolayers was investigated by π-A isotherm and X-ray reflectivity. Carpet layer (dense hydrophilic block layer formation under the hydrophobic layer was confirmed and a “brush” layer was found beneath the carpet layer. However, the thickness of brush layer was much thinner than that of the fully-stretched chain length. The critical salt concentration was found to be 0.01 M NaCl, which is much lower than that of the previous strongly anionic brush. These differences were probably caused by the low effective charge on the brush chains due to the hydrophobic nature of the quarternized ammonium cation.

  10. Preparing high-density polymer brushes by mechanically assisted polymer assembly (MAPA)

    Science.gov (United States)

    Wu, Tao; Efimenko, Kirill; Genzer, Jan

    2001-03-01

    We introduce a novel method of modifying the surface properties of materials. This technique, called MAPA (="mechanically assisted polymer assembly"), is based on: 1) chemically attaching polymerization initiators to the surface of an elastomeric network that has been previously stretched by a certain length, Δx, and 2) growing end-anchored macromolecules using surface initiated ("grafting from") atom transfer living radical polymerization. After the polymerization, the strain is removed from the substrate, which returns to its original size causing the grafted macromolecules to stretch away from the substrate and form a dense polymer brush. We demonstrate the feasibility of the MAPA method by preparing high-density polymer brushes of poly(acryl amide), PAAm. We show that, as expected, the grafting density of the PAAm brushes can be increased by increasing Δx. We demonstrate that polymer brushes with extremely high grafting densities can be successfully prepared by MAPA.

  11. Emerging insights into the roles of membrane tethers from analysis of whole organisms: The tip of an iceberg?

    Directory of Open Access Journals (Sweden)

    Wei Hong eToh

    2016-02-01

    Full Text Available Membrane tethers have been identified throughout different compartments of the endomembrane system. It is now well established that a number of membrane tethers mediate docking of membrane carriers in anterograde and retrograde transport and in regulating the organization of membrane compartments. Much of our information on membrane tethers have been obtained from the analysis of individual membrane tethers in cultured cells. In the future it will be important to better appreciate the network of interactions mediated by tethers and the potential co-ordination of their collective functions in vivo. There are now a number of studies which have analyzed membrane tethers in tissues and organisms which are providing new insights into the role of this class of membrane protein at the physiological level. Here we review recent advances in the understanding of the function of membrane tethers from knock outs (or knock downs in whole organisms and from mutations in tethers associated with disease.

  12. Strong Stretching of Poly(ethylene glycol) Brushes Mediated by Ionic Liquid Solvation.

    Science.gov (United States)

    Han, Mengwei; Espinosa-Marzal, Rosa M

    2017-09-07

    We have measured forces between mica surfaces coated with a poly(ethylene glycol) (PEG) brush solvated by a vacuum-dry ionic liquid, 1-ethyl-3-methyl imidazolium bis(trifluoromethylsulfonyl)imide, with a surface forces apparatus. At high grafting density, the solvation mediated by the ionic liquid causes the brush to stretch twice as much as in water. Modeling of the steric repulsion indicates that PEG behaves as a polyelectrolyte; the hydrogen bonding between ethylene glycol and the imidazolium cation seems to effectively charge the polymer brush, which justifies the strong stretching. Importantly, under strong polymer compression, solvation layers are squeezed out at a higher rate than for the neat ionic liquid. We propose that the thermal fluctuations of the PEG chains, larger in the brush than in the mushroom configuration, maintain the fluidity of the ionic liquid under strong compression, in contrast to the solid-like squeezing-out behavior of the neat ionic liquid. This is the first experimental study of the behavior of a polymer brush solvated by an ionic liquid under nanoconfinement.

  13. Experiments and simulation of a net closing mechanism for tether-net capture of space debris

    Science.gov (United States)

    Sharf, Inna; Thomsen, Benjamin; Botta, Eleonora M.; Misra, Arun K.

    2017-10-01

    This research addresses the design and testing of a debris containment system for use in a tether-net approach to space debris removal. The tether-net active debris removal involves the ejection of a net from a spacecraft by applying impulses to masses on the net, subsequent expansion of the net, the envelopment and capture of the debris target, and the de-orbiting of the debris via a tether to the chaser spacecraft. To ensure a debris removal mission's success, it is important that the debris be successfully captured and then, secured within the net. To this end, we present a concept for a net closing mechanism, which we believe will permit consistently successful debris capture via a simple and unobtrusive design. This net closing system functions by extending the main tether connecting the chaser spacecraft and the net vertex to the perimeter and around the perimeter of the net, allowing the tether to actuate closure of the net in a manner similar to a cinch cord. A particular embodiment of the design in a laboratory test-bed is described: the test-bed itself is comprised of a scaled-down tether-net, a supporting frame and a mock-up debris. Experiments conducted with the facility demonstrate the practicality of the net closing system. A model of the net closure concept has been integrated into the previously developed dynamics simulator of the chaser/tether-net/debris system. Simulations under tether tensioning conditions demonstrate the effectiveness of the closure concept for debris containment, in the gravity-free environment of space, for a realistic debris target. The on-ground experimental test-bed is also used to showcase its utility for validating the dynamics simulation of the net deployment, and a full-scale automated setup would make possible a range of validation studies of other aspects of a tether-net debris capture mission.

  14. Applications of functional polymer brushes for nanoparticle uptake and prevention of protein adsorption

    Science.gov (United States)

    Arifuzzaman, Shafi M.

    The central theme of this Ph.D. dissertation is to develop novel multifunctional polymer coatings for understanding partition of proteins and nanoparticles on polymers grafted to flat surfaces (so-called brushes). Systematic investigation of the adsorption phenomena is accomplished by utilizing surface-anchored assemblies comprising grafted polymers with variation in physical properties (i.e., length or/and grafting density) and chemical functionality. The chemical composition of the brush is tailored by either "chemical coloring" of a parent homopolymer brush with selective chemical moieties or by sequential growth of two chemically dissimilar polymer blocks. We present preparation of two types of tailor-made, surface-grafted copolymers: (1) those composed of hydrophilic and hydrophobic blocks (so-called amphiphilic polymer brushes), and (2) those comprising of anionic and cationic polymer segments (so-called polyampholyte brushes). We describe the organization of functionality in the grafted polymer brushes and the partitioning of proteins and nanoparticles using a battery of complementary analytical probes. Specifically, we address how varying the molecular weight, grafting density, and chemical composition of the brush affects adsorbtion and desorbtion of model proteins and gold nanoparticles. Our observations indicate densely-populated responsive amphiphilic polymers are very efficient in suppressing protein adsorption. In addition, we have established that the length of poly(ethylene glycol) spacers attached to a parent homopolymer brush is a key factor governing uptake of gold nanoparticles. Both grafting density and molecular weight of the coating are important in controlling the kinetics and thermodynamics of protein adsorption on surfaces. Our findings and methodologies can lead to the development of next generation environmentally friendly antifouling surfaces and will find application in medical devices, antifouling coatings and anti reflection finishes.

  15. Cooperative networks : The mobile tethering game

    NARCIS (Netherlands)

    Constantinescu, M.; Bouwman, H.; Djurica, M.; Durmus, Y.; Onur, E.; Reuver, M. de

    2012-01-01

    We propose an analysis of cooperation for data sharing and the behavioral aspects involved in the process of decision making. Starting with the tethering capabilities of recent devices we apply game theoretical principles and models, inquire what makes the cooperation work, and what are the

  16. Calves Use an Automated Brush and a Hanging Rope When Pair-Housed

    Directory of Open Access Journals (Sweden)

    Gosia Zobel

    2017-11-01

    Full Text Available Calf housing often only meets the basic needs of calves, but there is a growing interest in providing enrichments. This study described the behaviour of calves when they were given the opportunity to interact with two commonly available enrichment items. Female and male calves (approximately 11 days old were pair-housed in 8 identical pens fitted with an automated brush and a hanging rope. Frequency and duration of behaviours were recorded on 3 separate days (from 12:00 until 08:00 the following day. Calves spent equal time using the brush and rope (27.1 min/day, but there was less variation in the use of the brush as opposed to the rope (coefficient of variation, CV: 23 vs. 78%, respectively. Calves had more frequent (94 bouts, CV: 24% and shorter (17.8 s/bout, CV: 24% brush use bouts compared to fewer (38 bouts, CV: 43% and longer (38.3 s/bout, CV: 53% rope use bouts. There was a diurnal pattern of use for both items. Frequency of play was similar to rope use, but total time playing was 8% of rope and brush use. Variability among calves suggested that individual preference existed; however, the social dynamics of the pair-housed environment were not measured and therefore could have influenced brush and rope use. Multiple enrichment items should be considered when designing improvements to calf housing.

  17. Development of the Upgraded DC Brush Gear Motor for Spacebus Platforms

    Science.gov (United States)

    Berning, Robert H.; Viout, Olivier

    2010-01-01

    The obsolescence of materials and processes used in the manufacture of traditional DC brush gear motors has necessitated the development of an upgraded DC brush gear motor (UBGM). The current traditional DC brush gear motor (BGM) design was evaluated using Six-Sigma process to identify potential design and production process improvements. The development effort resulted in a qualified UBGM design which improved manufacturability and reduced production costs. Using Six-Sigma processes and incorporating lessons learned during the development process also improved motor performance for UBGM making it a more viable option for future use as a deployment mechanism in space flight applications.

  18. ER-to-plasma membrane tethering proteins regulate cell signaling and ER morphology.

    Science.gov (United States)

    Manford, Andrew G; Stefan, Christopher J; Yuan, Helen L; Macgurn, Jason A; Emr, Scott D

    2012-12-11

    Endoplasmic reticulum-plasma membrane (ER-PM) junctions are conserved structures defined as regions of the ER that tightly associate with the plasma membrane. However, little is known about the mechanisms that tether these organelles together and why such connections are maintained. Using a quantitative proteomic approach, we identified three families of ER-PM tethering proteins in yeast: Ist2 (related to mammalian TMEM16 ion channels), the tricalbins (Tcb1/2/3, orthologs of the extended synaptotagmins), and Scs2 and Scs22 (vesicle-associated membrane protein-associated proteins). Loss of all six tethering proteins results in the separation of the ER from the PM and the accumulation of cytoplasmic ER. Importantly, we find that phosphoinositide signaling is misregulated at the PM, and the unfolded protein response is constitutively activated in the ER in cells lacking ER-PM tether proteins. These results reveal critical roles for ER-PM contacts in cell signaling, organelle morphology, and ER function. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Tethered balloon-based measurements of meteorological variables and aerosols

    Science.gov (United States)

    Sentell, R. J.; Storey, R. W.; Chang, J. J. C.; Jacobsen, S. J.

    1976-01-01

    Tethered balloon based measurements of the vertical distributions of temperature, humidity, wind speed, and aerosol concentrations were taken over a 4-hour period beginning at sunrise on June 29, 1976, at Wallops Island, Virginia. Twelve consecutive profiles of each variable were obtained from ground to about 500 meters. These measurements were in conjuction with a noise propagation study on remotely arrayed acoustic range (ROMAAR) at Wallops Flight Center. An organized listing of these vertical soundings is presented. The tethered balloon system configuration utilized for these measurements is described.

  20. Hydration of poly( N-isopropylacrylamide) brushes on micro-silica beads measured by a fluorescent probe

    Science.gov (United States)

    Hattori, Yusuke; Nagase, Kenichi; Kobayashi, Jun; Kikuchi, Akihiko; Akiyama, Yoshikatsu; Kanazawa, Hideko; Okano, Teruo

    2010-05-01

    Hydration of poly( N-isopropylacrylamide) brushes on silica micro-beads was investigated using a fluorescent probe method. The free ends, the bottom, and the random of brushes were labeled with dansyl group. The emission spectra at the thin brushes were reduced with increasing temperature regardless of their labeling locations. At the free ends of thick brushes, the emission intensity was enhanced at 500 nm and reduced at 455 nm by heating, which was corresponding to the local micro-environmental change around the free ends. The spectral shift was speculated to be due to the enhancement of the flexibility and the hydration of thick brushes.

  1. Analysis of carbon fiber brush loading in anodes on startup and performance of microbial fuel cells

    KAUST Repository

    Hutchinson, Adam J.

    2011-11-01

    Flat carbon anodes placed near a cathode in a microbial fuel cell (MFC) are adversely affected by oxygen crossover, but graphite fiber brush anodes placed near the cathode produce high power densities. The impact of the brush size and electrode spacing was examined by varying the distance of the brush end from the cathode and solution conductivity in multiple MFCs. The startup time was increased from 8 ± 1 days with full brushes (all buffer concentrations) to 13 days (50 mM), 14 days (25 mM) and 21 days (8 mM) when 75% of the brush anode was removed. When MFCs were all first acclimated with a full brush, up to 65% of the brush material could be removed without appreciably altering maximum power. Electrochemical impedance spectroscopy (EIS) showed that the main source of internal resistance (IR) was diffusion resistance, which together with solution resistance reached 100 Ω. The IR using EIS compared well with that obtained using the polarization data slope method, indicating no major components of IR were missed. These results show that using full brush anodes avoids adverse effects of oxygen crossover during startup, although brushes are much larger than needed to sustain high power. © 2011 Elsevier B.V.

  2. Analysis of carbon fiber brush loading in anodes on startup and performance of microbial fuel cells

    KAUST Repository

    Hutchinson, Adam J.; Tokash, Justin C.; Logan, Bruce E.

    2011-01-01

    Flat carbon anodes placed near a cathode in a microbial fuel cell (MFC) are adversely affected by oxygen crossover, but graphite fiber brush anodes placed near the cathode produce high power densities. The impact of the brush size and electrode spacing was examined by varying the distance of the brush end from the cathode and solution conductivity in multiple MFCs. The startup time was increased from 8 ± 1 days with full brushes (all buffer concentrations) to 13 days (50 mM), 14 days (25 mM) and 21 days (8 mM) when 75% of the brush anode was removed. When MFCs were all first acclimated with a full brush, up to 65% of the brush material could be removed without appreciably altering maximum power. Electrochemical impedance spectroscopy (EIS) showed that the main source of internal resistance (IR) was diffusion resistance, which together with solution resistance reached 100 Ω. The IR using EIS compared well with that obtained using the polarization data slope method, indicating no major components of IR were missed. These results show that using full brush anodes avoids adverse effects of oxygen crossover during startup, although brushes are much larger than needed to sustain high power. © 2011 Elsevier B.V.

  3. The use of non-bronchoscopic brushings to study the paediatric airway

    Directory of Open Access Journals (Sweden)

    Kicic Anthony

    2005-06-01

    Full Text Available Abstract Background The use of cytology brushes for the purpose of obtaining respiratory cells from adults for clinical and research purposes is well established. However, the safety and utility of non-bronchoscopic brushings to study the paediatric airway has not been assessed. The purpose of this study was to assess the practicality of using non-bronchoscopic brushing to sample epithelial cells from children for investigation of epithelial function in health and disease using a wide range of molecular and cellular techniques. Methods Non-bronchoscopic brushing was investigated in a non-selected cohort of healthy, and mildly asthmatic children presenting for surgery unrelated to respiratory conditions, at the major children's hospital in Perth. Safety and side-effects of the procedure were assessed. Cell number, phenotype and viability were measured for all samples. The potential of these cells for use in long-term cell culture, immunohistochemistry, western blotting, quantitative PCR and gene arraying was examined. Results Non-bronchoscopic brushing was well tolerated in all children. The only significant side effect following the procedure was cough: nursing staff reported cough in 20% of patients; parents reported cough in 40% of patients. Cells sampled were of sufficient quantity and quality to allow cell culture in 93% of samples. Similarly, protein and RNA extracted from the cells was suitable for investigation of both gene and protein expression using micro-array and real-time PCR. Conclusion Non-bronchoscopic brushing in children is safe and easy to perform, and is not associated with any complications. Using this technique, adequate numbers of epithelial cells can be retrieved to allow cell culture, western blotting, real time PCR, and microarray analysis. The purpose of this study is to demonstrate the utility of non-bronchoscopic airway brushing to obtain and study epithelial cells and to encourage others so that we can accelerate

  4. Measurement of Tooth Brushing Frequency, Time of Day and Duration of Adults and Children in Jakarta, Indonesia

    Directory of Open Access Journals (Sweden)

    Anton Rahardjo

    2015-05-01

    Full Text Available Epidemiological study of tooth brushing is essential to evaluate dental health of a country. Objective: To obtain data on tooth brushing frequency, time of day and duration from adults and children in Jakarta, Indonesia. Methods: Toothbrushes containing data loggers were distributed to 120 random families in Jakarta to record how many times a day, when and for how long subjects brushed their teeth. The families were each composed of a mother, father and two children aged between 6 and 15 years. Results: The mean brushing frequency of the population was 1.27 times per day. The majority of the tooth brushing (46% was performed in the morning. The mean tooth brushing duration of this population was 57.29 seconds. The mothers’ tooth brushing frequencies tended to be higher than that of the other family members, and the fathers tended to brush their teeth longer. Conclusion: Effective education aimed at increasing both the duration and frequency of tooth brushing from once to twice per day is urgently required in Indonesia.DOI: 10.14693/jdi.v21i3.251

  5. Frequency of daily tooth brushing: predictors of change in 9- to 11-year old US children.

    Science.gov (United States)

    Polk, D E; Geng, M; Levy, S; Koerber, A; Flay, B R

    2014-09-01

    To investigate whether an increase in daily tooth brushing frequency in children was predicted by either a) having a strong intention to brush twice a day or b) their parents receiving information about their new caries experience. Secondary data analyses were conducted on two waves of data from the Aban Aya Youth Project and the Iowa Fluoride Study. The Aban Aya study included 576 10- and 11-year olds from Chicago, Illinois. The Iowa Fluoride Study included a convenience sample of 709 babies born in Iowa. The present study includes those children at age 9. In both studies, reported daily tooth brushing frequency was assessed twice six months apart. In the Aban Aya data, compared with children with a weak intention at wave 1 to brush twice a day, children with a strong intention to brush twice a day were more likely to increase their brushing frequency by wave 2, OR 7.0, 95%CI 1.5,32.9. In the Iowa Fluoride Study, compared with children who did not have new caries at wave 1, children who had new caries experience were less likely to increase their brushing frequency by wave 2, OR 0.4, 95%CI 0.2,0.9. Strengthening intention to brush twice a day might increase children's brushing frequency. However, simply providing parents with information about new caries probably will not. Future studies should assess tooth brushing frequency, habit strength, intention, and situational cues at closely-spaced waves.

  6. Features of Running Brush Motors in Dry Nitrogen Environment When Using in Electrohydraulic Actuators

    Directory of Open Access Journals (Sweden)

    Y. A. Petrov

    2014-01-01

    Full Text Available The work concerns the constructive characteristics optimization of brushless D.C. (direct current motors used in electromechanical spacecraft drives.The spacecraft electromechanical drives and units use rather widely the brushless D.C. motors in which a motor commutator is replaced with more reliable semiconductor commutator controlled by the rotor position sensors. However, these motors are of low power.Electrohydraulic actuators (EHA use simple permanent-magnet motors (PMM of rather high power and commutator motors with graphite brush variable contacts.High reliability of brush motors, and, therefore a reliability of EHA in general, substantially depends on the quality of motor commutator operation. There are different reasons for a possible impact on the normal motor commutator operation. One of them is brush wear. Sparking brushes and burning commutator bars are possible in case brushes are poorly grinded to fit, brushes cannot freely move true in the brush holder box, and in case an incorrect force to clamp brushes to the commutator is chosen.It is established that drive wear resistance and operability depends on the gas environment composition being under sealed motor housing. In dry nitrogen environment brush wear suddenly raises because of the changing tribological performances of the commutator thus leading to essentially falling isolation resistance and no motor start.It is recommended to fill a space under sealed motor housing with air. Positive experience of operating spacecraft device containers with mobile electromechanical couples allowed us to find that in this case a dew point of filled air must be minus 20˚C.The paper offers an electromechanical alternative of design to the electrohydraulic actuators, with a ball-screw gear of the actuation mechanism, possessing a number of advantages.

  7. Metastatic urachal carcinoma in bronchial brush cytology

    Directory of Open Access Journals (Sweden)

    Fatima Zahra Aly

    2013-01-01

    Full Text Available Urachal carcinoma is rare comprising less than 1% of all bladder carcinomas. Metastases of urachal carcinoma have been reported to meninges, brain, ovary, lung, and maxilla. Cytologic features of metastatic urachal carcinoma have not been previously reported. We present a case of metastatic urachal adenocarcinoma in bronchial brushings and review the use of immunohistochemistry in its diagnosis. A 47-year-old female was seen initially in 2007 with adenocarcinoma of the bladder dome for which she underwent partial cystectomy. She presented in 2011 with a left lung mass and mediastinal adenopathy. Bronchoscopy showed an endobronchial lesion from which brushings were obtained. These showed numerous groups of columnar cells with medium sized nuclei and abundant cytoplasm. The cells were positive for CK20 and CDX2 and negative for CK7. The cytomorphological findings were similar to those in the previous resection specimen and concurrent biopsy. This is the first case report of bronchial brushings containing metastatic urachal carcinoma. No specific immunohistochemical profile is available for its diagnosis. The consideration of a second primary was a distinct possibility in this case due to the lapse of time from primary resection, absence of local disease, and lack of regional metastases.

  8. A hybrid floating brush seal (HFBS) for improved sealing and wear performance in turbomachinery applications

    Science.gov (United States)

    Lattime, Scott Byran

    A conceptually new type of seal has been developed for gas turbine applications which dramatically reduces wear and leakage associated with current labyrinth and brush seal technologies. The Hybrid Floating Brush Seal (HFBS) combines brush seal and film riding face seal technologies to create a hybrid seal that allows both axial and radial excursions of the sealed shaft, while simultaneously eliminating interface surface speeds (friction and heat) between the rotor and the brush material that characterize standard brush seal technology. A simple test rig was designed to evaluate feasibility of the HFBS under relatively low pressures and rotational speeds (50psig, 5krpm). A second test stand was created to study the effects of centrifugal force on bristle deflection. A third test facility was constructed for prototype development and extensive room temperature testing at moderate pressures and fairly high rotational speeds (100psig, 40krpm). This test rig also allowed the evaluation of the HFBS during axial movement of a rotating shaft. An analytical model to predict the effects of centrifugal force on the bristles of a rotating brush seal was developed. Room temperature analysis of the HFBS proved successful for relatively high operating rotational velocities at moderate pressures with very acceptable leakage rates for gas turbine engines. Brush seals were able to track rotor speeds up to 24krpm while maintaining sealing integrity. The HFBS's ability to function under axial shaft displacement and synchronous dynamic radial loading was also proven successful. Hydrodynamic performance of the face seal was proven to provide adequate stiffness and load carrying capacity to keep the brush seal from contacting the face seal at pressure drops across the brush of up to 100psi. Leakage performance over standard brush seal and labyrinth technology was quite dramatic. The HFBS showed its sealing advantage using much higher radial interference between the rotor and the bristle

  9. A tethering complex drives the terminal stage of SNARE-dependent membrane fusion

    Science.gov (United States)

    D'Agostino, Massimo; Risselada, Herre Jelger; Lürick, Anna; Ungermann, Christian; Mayer, Andreas

    2017-11-01

    Membrane fusion in eukaryotic cells mediates the biogenesis of organelles, vesicular traffic between them, and exo- and endocytosis of important signalling molecules, such as hormones and neurotransmitters. Distinct tasks in intracellular membrane fusion have been assigned to conserved protein systems. Tethering proteins mediate the initial recognition and attachment of membranes, whereas SNARE (soluble N-ethylmaleimide-sensitive factor attachment protein receptor) protein complexes are considered as the core fusion engine. SNARE complexes provide mechanical energy to distort membranes and drive them through a hemifusion intermediate towards the formation of a fusion pore. This last step is highly energy-demanding. Here we combine the in vivo and in vitro fusion of yeast vacuoles with molecular simulations to show that tethering proteins are critical for overcoming the final energy barrier to fusion pore formation. SNAREs alone drive vacuoles only into the hemifused state. Tethering proteins greatly increase the volume of SNARE complexes and deform the site of hemifusion, which lowers the energy barrier for pore opening and provides the driving force. Thereby, tethering proteins assume a crucial mechanical role in the terminal stage of membrane fusion that is likely to be conserved at multiple steps of vesicular traffic. We therefore propose that SNAREs and tethering proteins should be considered as a single, non-dissociable device that drives fusion. The core fusion machinery may then be larger and more complex than previously thought.

  10. Observing Formation of Flux Rope by Tether-cutting Reconnection in the Sun

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Zhike; Yan, Xiaoli; Yang, Liheng; Wang, Jincheng; Zhao, Li, E-mail: zkxue@ynao.ac.cn [Yunnan Observatories, Chinese Academy of Sciences, Kunming Yunnan 650216 (China)

    2017-05-10

    Tether-cutting reconnection is considered as one mechanism for the formation of a flux rope. It has been proposed for more than 30 years; however, so far, direct observations of it are very rare. In this Letter, we present observations of the formation of a flux rope via tether-cutting reconnection in NOAA AR 11967 on 2014 February 2 by combining observations with the New Vacuum Solar Telescope and the Solar Dynamic Observatory . The tether-cutting reconnection occurs between two sets of highly sheared magnetic arcades. Comprehensive observational evidence of the reconnection is as follows: changes of the connections between the arcades, brightenings at the reconnection site, hot outflows, formation of a flux rope, slow-rise motion of the flux rope, and flux cancelation. The outflows are along three directions from the reconnection site to the footpoints with the velocities from 24 ± 1 km s{sup −1} to 69 ± 5 km s{sup −1}. Additionally, it is found that the newly formed flux rope connects far footpoints and has a left-handed twisted structure with many fine threads and a concave-up-shape structure in the middle. All the observations are in agreement with the tether-cutting model and provide evidence that tether-cutting reconnection leads to the formation of the flux rope associated with flux shear flow and cancelation.

  11. Relaxation Dynamics of Nanoparticle-Tethered Polymer Chains

    KAUST Repository

    Kim, Sung A; Mangal, Rahul; Archer, Lynden A.

    2015-01-01

    © 2015 American Chemical Society. Relaxation dynamics of nanoparticle-tethered cis-1,4-polyisoprene (PI) are investigated using dielectric spectroscopy and rheometry. A model system composed of polymer chains densely grafted to spherical SiO2

  12. Phobos L1 Operational Tether Experiment (PHLOTE)

    Data.gov (United States)

    National Aeronautics and Space Administration — A sensor package that “floats” just above the surface of Phobos, suspended by a tether from a small spacecraft operating at the Mars/Phobos Lagrange 1 (L1) Point...

  13. Making strong polyelectrolyte brushes pH-sensitive by incorporation of gold nanoparticles.

    Science.gov (United States)

    Boyaciyan, D; Krause, P; von Klitzing, R

    2018-04-19

    Doping polymer brushes with gold nanoparticles (AuNPs) results in composite materials with colorimetric sensor properties. The present paper addresses the effect of electrostatic particle-particle interaction and the effect of the polymer brush type on particle assembly formation within the polymer matrix. The prospect for long-term use as colorimetric sensors is tested. Therefore, two different types of brushes of pH-insensitive polymers, non-ionic poly(N-isopropylacrylamide) (PNIPAM) and cationic poly-[2-(methacryloyloxy)ethyl] trimethylammonium chloride (PMETAC), are studied. After incubation of the non-ionic PNIPAM brush in an aqueous suspension of AuNPs with a pH-sensitive carboxylic acid capping, hydrogen binding led to attachment of the AuNPs, but they were easily detached at high pH due to loss of the hydrogen binding. In contrast, the anionic AuNPs adhere well to cationic PMETAC brushes even after post-treatment at low pH where the charge density of the AuNPs is strongly reduced. Therefore, the PMETAC/AuNP composites were further tested with respect to their stability against pH variations and their impact for colorimetric sensors. Although the neat PMETAC brush is not pH-sensitive, after embedding pH-sensitive AuNPs, the PMETAC/AuNP composite becomes pH-sensitive in a reversible manner. This is detectable by the reversible shift of the plasmon band and the reversible thickness change of the composites by exposing them to different pH.

  14. Polymer Brush-Functionalized Chitosan Hydrogels as Antifouling Implant Coatings.

    Science.gov (United States)

    Buzzacchera, Irene; Vorobii, Mariia; Kostina, Nina Yu; de Los Santos Pereira, Andres; Riedel, Tomáš; Bruns, Michael; Ogieglo, Wojciech; Möller, Martin; Wilson, Christopher J; Rodriguez-Emmenegger, Cesar

    2017-06-12

    Implantable sensor devices require coatings that efficiently interface with the tissue environment to mediate biochemical analysis. In this regard, bioinspired polymer hydrogels offer an attractive and abundant source of coating materials. However, upon implantation these materials generally elicit inflammation and the foreign body reaction as a consequence of protein fouling on their surface and concomitant poor hemocompatibility. In this report we investigate a strategy to endow chitosan hydrogel coatings with antifouling properties by the grafting of polymer brushes in a "grafting-from" approach. Chitosan coatings were functionalized with polymer brushes of oligo(ethylene glycol) methyl ether methacrylate and 2-hydroxyethyl methacrylate using photoinduced single electron transfer living radical polymerization and the surfaces were thoroughly characterized by XPS, AFM, water contact angle goniometry, and in situ ellipsometry. The antifouling properties of these new bioinspired hydrogel-brush coatings were investigated by surface plasmon resonance. The influence of the modifications to the chitosan on hemocompatibility was assessed by contacting the surfaces with platelets and leukocytes. The coatings were hydrophilic and reached a thickness of up to 180 nm within 30 min of polymerization. The functionalization of the surface with polymer brushes significantly reduced the protein fouling and eliminated platelet activation and leukocyte adhesion. This methodology offers a facile route to functionalizing implantable sensor systems with antifouling coatings that improve hemocompatibility and pave the way for enhanced device integration in tissue.

  15. The synthesis of hydrogels with controlled distribution of polymer brushes in hydrogel network

    Energy Technology Data Exchange (ETDEWEB)

    Sun, YuWei; Zhou, Chao; Zhang, AoKai; Xu, LiQun; Yao, Fang [School of Chemistry and Chemical Engineering, Southeast University, Jiangning District, Nanjing, Jiangsu Province, 211189 (China); Cen, Lian, E-mail: cenlian@hotmail.com [National Tissue Engineering Center of China, No.68, East Jiang Chuan Road, Shanghai, 200241 (China); School of Chemical Engineering, East China University of Science and Technology, No.130, Mei Long Road, Shanghai, 200237 (China); Fu, Guo-Dong, E-mail: fu7352@seu.edu.cn [School of Chemistry and Chemical Engineering, Southeast University, Jiangning District, Nanjing, Jiangsu Province, 211189 (China)

    2014-11-30

    Highlights: • Many biological tissues are 3-dimensionally asymmetric in structure and properties, it would be desirable if hydrogels could bear such structural similarity with specialized surface and bulk properties. Moreover, gradual but continuous variation in spatial structural and property is also a common phenomenon in biological tissues, such as interfaces between bone and tendon, or between bone and cartilage. Hence, the development of a method to introduce well-defined functional polymer brushes on PEG hydrogels, especially with precisely controlled spatial structure in 3-dimensions, would impart the hydrogels with special functionalities and wider applications. Poly(ethylene glycol) (PEG) hydrogels with 3-dimensionally controlled well-defined poly(N-isopropylacrylamide) (poly(NIPAAm)) brushes were prepared by combined copper(I)-catalyzed azide-alkyne cycloaddition (“Click Chemistry”) and atom transfer radical polymerization (ATRP). The resulting hydrogels were presented as representatives with their detailed synthesis routes and characterization. H{sub PEG}-S-poly(NIPAAm) is a hydrogel with poly(NIPAAm) brushes mainly grafted on surface, whereas H{sub PEG}-G-poly(NIPAAm) has a gradiently decreased poly(NIPAAm) brushes in their chain length from surface to inside. On the other hand, poly(NIPAAm) brushes in H{sub PEG}-U-poly(NIPAAm) are uniformly dispersed throughout the whole hydrogel network. Successful preparation of H{sub PEG}-S-poly(NIPAAm), H{sub PEG}-G-poly(NIPAAm) and H{sub PEG}-U-poly(NIPAAm) were ascertained by X-ray photoelectron spectroscopy (XPS) and water contact angle measurement. Hence, the flexibility and controllability of the synthetic strategy in varying the distribution of polymer brushes and hydrogel surface properties was demonstrated. Hydrogels with tunable and well-defined 3-dimensional poly(NIPAAm) polymer brushes could be tailor-designed to find potential applications in smart devices or skin dressing, such as for diabetics

  16. Peptides Displayed as High Density Brush Polymers Resist Proteolysis and Retain Bioactivity

    Science.gov (United States)

    2015-01-01

    We describe a strategy for rendering peptides resistant to proteolysis by formulating them as high-density brush polymers. The utility of this approach is demonstrated by polymerizing well-established cell-penetrating peptides (CPPs) and showing that the resulting polymers are not only resistant to proteolysis but also maintain their ability to enter cells. The scope of this design concept is explored by studying the proteolytic resistance of brush polymers composed of peptides that are substrates for either thrombin or a metalloprotease. Finally, we demonstrate that the proteolytic susceptibility of peptide brush polymers can be tuned by adjusting the density of the polymer brush and offer in silico models to rationalize this finding. We contend that this strategy offers a plausible method of preparing peptides for in vivo use, where rapid digestion by proteases has traditionally restricted their utility. PMID:25314576

  17. Lumbosacral arachnoid cyst with tethered cord: A rare case report

    Directory of Open Access Journals (Sweden)

    S K Jain

    2012-01-01

    Full Text Available Arachnoid cysts are cerebrospinal fluid collections in the spine that can present with neurological symptoms or be discovered accidentally. Intradural location of such cysts especially in the lumbosacral region is relatively rare. The association of such cysts with other congenital anomalies such as tethered cord lends evidence to the developmental origin of arachnoid cysts. We report a case of lumbosacral arachnoid cyst with tethered cord in a 6-year-old male child and discuss the etiopathogenesis and management options.

  18. Unilateral pedicle screws asymmetric tethering: an innovative method to create idiopathic deformity

    Directory of Open Access Journals (Sweden)

    Zhang Xuesong

    2007-10-01

    Full Text Available Abstract Objective To evaluate the feasibility of the method that unilateral pedicle screws asymmetric tethering in concave side in combination with convex rib resection for creating idiopathic deformity. Summary of background data Various methods are performed to create idiopathic deformity. Among these methods, posterior asmmetric tethering of the spine shows satisfying result, but some drawbacks related to the current posterior asymmetric tether were still evident. Materials and methods Unilateral pedicle screws asymmetric tethering was performed to 14 female goats (age: 5–8 week-old, weight: 6–8 kg in concave side in combination with convex rib resection. Dorsoventral and lateral plain radiographs were taken of each thoracic spine in the frontal and sagittal planes right after the surgery and later every 4 weeks. Results All animals ambulated freely after surgery. For technical reasons, 2 goats were excluded (one animal died for anesthetic during the surgery, and one animal was lost for instrumental fail due to postoperative infection. Radiography showed that 11 goats exhibited scoliosis with convex toward to the right side, and as the curve increased with time, only 1 goat showed nonprogressive. The initial scoliosis generated in the progressors after the procedures measured 29.0° on average (range 23.0°–38.5° and increased to 43.0° on average (range 36.0°–58.0° over 8 to 10 weeks. The average progression of 14.0° was measured. The curvature immediately after tethering surgery (the initial Cobb angle did have a highly significant correlation with the final curvature (p Conclusion Unilateral pedicle screws asymmetric tethering is a practical method to create experimental scoliosis, especially for those who would like to study the correction of this deformity.

  19. Spectroscopic study of a DNA brush synthesized in situ by surface initiated enzymatic polymerization.

    Science.gov (United States)

    Khan, M Nuruzzaman; Tjong, Vinalia; Chilkoti, Ashutosh; Zharnikov, Michael

    2013-08-29

    We used a combination of synchrotron-based X-ray photoelectron spectroscopy (XPS) and angle-resolved near-edge X-ray absorption fine structure (NEXAFS) spectroscopy to study the chemical integrity, purity, and possible internal alignment of single-strand (ss) adenine deoxynucleotide (poly(A)) DNA brushes. The brushes were synthesized by surface-initiated enzymatic polymerization (SIEP) on a 25-mer of adenine self-assembled monolayer (SAM) on gold (A25-SH), wherein the terminal 3'-OH of the A25-SH serve as the initiation sites for SIEP of poly(A). XPS and NEXAFS spectra of poly(A) brushes were found to be almost identical to those of A25-SH initiator, with no unambiguous traces of contamination. Apart from the well-defined chemical integrity and contamination-free character, the brushes were found to have a high degree of orientational order, with an upright orientation of individual strands, despite their large thickness up to ~55 nm, that corresponds to a chain length of at least several hundred nucleotides for individual ssDNA molecules. The orientational order exhibited by these poly(A) DNA brushes, mediated presumably by base stacking, was found to be independent of the brush thickness as long as the packing density was high enough. The well-defined character and orientational ordering of the ssDNA brushes make them a potentially promising system for different applications.

  20. Effect of tooth brushing on gloss retention and surface roughness of five bulk-fill resin composites.

    Science.gov (United States)

    O'Neill, Catherine; Kreplak, Laurent; Rueggeberg, Frederick A; Labrie, Daniel; Shimokawa, Carlos Alberto Kenji; Price, Richard Bengt

    2018-01-01

    To determine the effects of tooth brushing on five bulk-fill resin based composites (RBCs). Ten samples of Filtek Supreme Enamel (control), Filtek One Bulk Fill, Tetric EvoCeram Bulk Fill, SonicFill 2, SDR flow+, and Admira Fusion X-tra were light cured for 20 seconds using the Valo Grand curing light. After 24 hours storage in air at 37°C, specimens were brushed in a random order using Colgate OpticWhite dentifrice and a soft toothbrush. Surface gloss was measured prior to brushing, after 5,000, 10,000 and 15,000 back and forth brushing cycles. Surface roughness was measured after 15,000 brushing cycles using atomic force microscopy (AFM) and selected scanning electron microscope (SEM) images were taken. The data was examined using ANOVA and pair-wise comparisons using Scheffe's post-hoc multiple comparison tests (α = 0.05). Surface gloss decreased and the surface roughness increased after brushing. Two-way ANOVA showed that both the RBC and the number of brushing cycles had a significant negative effect on the gloss. One-way ANOVA showed that the RBC had a significant effect on the roughness after 15,000 brushing cycles. For both gloss and roughness, brushing had the least effect on the nano-filled control and nano-filled bulk-fill RBC, and the greatest negative effect on Admira Fusion X-tra. The SEM images provided visual agreement. There was an excellent linear correlation (R 2  = 0.98) between the logarithm of the gloss and roughness. After brushing, the bulk-fill RBCs were all rougher than the control nano-filled RBC. The nano-filled bulk-fill RBC was the least affected by brushing. Bulk-fill RBCs lose their gloss faster and become rougher than the nanofilled conventional RBC, Filtek Supreme Ultra. The nanofilled bulk-fill RBC was the least affected by tooth brushing. © 2017 Wiley Periodicals, Inc.

  1. Titanium-tethered vancomycin prevents resistance to rifampicin in Staphylococcus aureus in vitro.

    Directory of Open Access Journals (Sweden)

    Martin Rottman

    Full Text Available Rifampicin is currently recognized as the most potent drug against Gram positive implant related infections. The use of rifampicin is limited by the emergence of bacterial resistance, which is often managed by coadministration of a second antibiotic. The purpose of this study was to determine the effectiveness of soluble rifampicin in combination with vancomycin tethered to titanium metal as a means to control bacterial growth and resistance in vitro. Bacterial growth was inhibited when the vancomycin-tethered titanium discs were treated with Staphylococcus aureus inocula of ≤2×10⁶ CFU, however inocula greater than 2×10⁶ CFU/disc adhered and survived. The combination of surface-tethered vancomycin with soluble rifampicin enhanced the inhibitory effect of rifampicin for an inoculum of 10⁶ CFU/cm² by one dilution (combination MIC of 0.008 mg/L versus 0.015 mg/L for rifampicin alone. Moreover, surface tethered vancomycin prevented the emergence of a rifampicin resistant population in an inoculum of 2×10⁸ CFU.

  2. Two-Stage Winch for Kites and Tethered Balloons or Blimps

    Science.gov (United States)

    Miles, Ted; Bland, Geoff

    2011-01-01

    A winch system provides a method for launch and recovery capabilities for kites and tethered blimps or balloons. Low power consumption is a key objective, as well as low weight for portability. This is accomplished by decoupling the tether-line storage and wind ing/ unwinding functions, and providing tailored and efficient mechanisms for each. The components of this system include rotational power input devices such as electric motors or other apparatus, line winding/unwinding reel(s), line storage reel(s), and independent drive trains. Power is applied to the wind/unwind reels to transport the tether line. Power is also applied to a line storage reel, from either the wind/unwind power source, the wind/unwind reel itself, or separate power source. The speeds of the two reels are synchronized, but not dependent on each other. This is accomplished via clutch mechanisms, variable transmissions, or independent motor controls. The speed of the storage reel is modulated as the effective diameter of the reel changes with line accumulation.

  3. Segment density profiles of polyelectrolyte brushes determined by Fourier transform ellipsometry

    Science.gov (United States)

    Biesalski, Markus; Rühe, Jürgen; Johannsmann, Diethelm

    1999-10-01

    We describe a method for the explicit determination of the segment density profile φ(z) of surface-attached polymer brushes with multiple angle of incidence null-ellipsometry. Because the refractive index contrast between the brush layer and the solvent is weak, multiple reflections are of minor influence and the ellipsometric spectrum is closely related to the Fourier transform of the refractive index profile, thereby allowing for explicit inversion of the ellipsometric data. We chose surface-attached monolayers of polymethacrylic acid (PMAA), a weak polyelectrolyte, as a model system and determined the segment density profile of this system as a function of the pH value of the surrounding medium by the Fourier method. Complementary to the Fourier analysis, fits with error functions are given as well. The brushes were prepared on the bases of high refractive index prisms with the "grafting-from" technique. In water, the brushes swell by more than a factor of 30. The swelling increases with increasing pH because of a growing fraction of dissociated acidic groups leading to a larger electrostatic repulsion.

  4. FCAPD Protective Coating for Space Tethers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Alameda Applied Sciences Corporation (AASC) proposes to demonstrate extended service lifetime of space tethers in the Low Earth Orbit (LEO) environment by using...

  5. The ATPases of cohesin interface with regulators to modulate cohesin-mediated DNA tethering

    Science.gov (United States)

    Çamdere, Gamze; Guacci, Vincent; Stricklin, Jeremiah; Koshland, Douglas

    2015-01-01

    Cohesin tethers together regions of DNA, thereby mediating higher order chromatin organization that is critical for sister chromatid cohesion, DNA repair and transcriptional regulation. Cohesin contains a heterodimeric ATP-binding Cassette (ABC) ATPase comprised of Smc1 and Smc3 ATPase active sites. These ATPases are required for cohesin to bind DNA. Cohesin’s DNA binding activity is also promoted by the Eco1 acetyltransferase and inhibited by Wpl1. Recently we showed that after cohesin stably binds DNA, a second step is required for DNA tethering. This second step is also controlled by Eco1 acetylation. Here, we use genetic and biochemical analyses to show that this second DNA tethering step is regulated by cohesin ATPase. Furthermore, our results also suggest that Eco1 promotes cohesion by modulating the ATPase cycle of DNA-bound cohesin in a state that is permissive for DNA tethering and refractory to Wpl1 inhibition. DOI: http://dx.doi.org/10.7554/eLife.11315.001 PMID:26583750

  6. Description of fuel element brush assembly's fabrication for 105-K west

    International Nuclear Information System (INIS)

    Maassen, D.P.

    1997-01-01

    This report is a description of the process to redesign and fabricate, as well as, describe the features of the Fuel Element Brush Assembly used in the 105-K West Basin. This narrative description will identify problems that occurred during the redesigning and fabrication of the 105-K West Basin Fuel Element Brush Assembly and specifically address their solutions

  7. The mechanics of motorised momentum exchange tethers when applied to active debris removal from LEO

    Energy Technology Data Exchange (ETDEWEB)

    Caldecott, Ralph; Kamarulzaman, Dayangku N. S.; Kirrane, James P.; Cartmell, Matthew P.; Ganilova, Olga A. [Department of Mechanical Engineering, University of Sheffield, Mappin St., Sheffield, S1 3JD, England (United Kingdom)

    2014-12-10

    The concept of momentum exchange when applied to space tethers for propulsion is well established, and a considerable body of literature now exists on the on-orbit modelling, the dynamics, and also the control of a large range of tether system applications. The authors consider here a new application for the Motorised Momentum Exchange Tether by highlighting three key stages of development leading to a conceptualisation that can subsequently be developed into a technology for Active Debris Removal. The paper starts with a study of the on-orbit mechanics of a full sized motorised tether in which it is shown that a laden and therefore highly massasymmetrical tether can still be forced to spin, and certainly to librate, thereby confirming its possible usefulness for active debris removal (ADR). The second part of the paper concentrates on the modelling of the centripetal deployment of a symmetrical MMET in order to get it initialized for debris removal operations, and the third and final part of the paper provides an entry into scale modelling for low cost mission design and testing. It is shown that the motorised momentum exchange tether offers a potential solution to the removal of large pieces of orbital debris, and that dynamic methodologies can be implemented to in order to optimise the emergent design.

  8. The mechanics of motorised momentum exchange tethers when applied to active debris removal from LEO

    International Nuclear Information System (INIS)

    Caldecott, Ralph; Kamarulzaman, Dayangku N. S.; Kirrane, James P.; Cartmell, Matthew P.; Ganilova, Olga A.

    2014-01-01

    The concept of momentum exchange when applied to space tethers for propulsion is well established, and a considerable body of literature now exists on the on-orbit modelling, the dynamics, and also the control of a large range of tether system applications. The authors consider here a new application for the Motorised Momentum Exchange Tether by highlighting three key stages of development leading to a conceptualisation that can subsequently be developed into a technology for Active Debris Removal. The paper starts with a study of the on-orbit mechanics of a full sized motorised tether in which it is shown that a laden and therefore highly massasymmetrical tether can still be forced to spin, and certainly to librate, thereby confirming its possible usefulness for active debris removal (ADR). The second part of the paper concentrates on the modelling of the centripetal deployment of a symmetrical MMET in order to get it initialized for debris removal operations, and the third and final part of the paper provides an entry into scale modelling for low cost mission design and testing. It is shown that the motorised momentum exchange tether offers a potential solution to the removal of large pieces of orbital debris, and that dynamic methodologies can be implemented to in order to optimise the emergent design

  9. Structural analysis of paintings based on brush strokes

    Science.gov (United States)

    Sablatnig, Robert; Kammerer, Paul; Zolda, Ernestine

    1998-05-01

    The origin of works of art can often not be attributed to a certain artist. Likewise it is difficult to say whether paintings or drawings are originals or forgeries. In various fields of art new technical methods are used to examine the age, the state of preservation and the origin of the materials used. For the examination of paintings, radiological methods like X-ray and infra-red diagnosis, digital radiography, computer-tomography, etc. and color analyzes are employed to authenticate art. But all these methods do not relate certain characteristics in art work to a specific artist -- the artist's personal style. In order to study this personal style of a painter, experts in art history and image processing try to examine the 'structural signature' based on brush strokes within paintings, in particular in portrait miniatures. A computer-aided classification and recognition system for portrait miniatures is developed, which enables a semi- automatic classification and forgery detection based on content, color, and brush strokes. A hierarchically structured classification scheme is introduced which separates the classification into three different levels of information: color, shape of region, and structure of brush strokes.

  10. Development of Self-Assembled Nanoscale Templates via Microphase Separation Induced by Polymer Brushes

    Science.gov (United States)

    Chu, Elza

    Phase separation in soft matter has been the crucial element in generating hybrid materials, such as polymer blends and mixed polymer brushes. This dissertation discusses two methods of developing self-assembled nanoscale templates via microphase separation induced by polymer brush synthesis. This work introduces a novel soft substrate approach with renewable grafting sites where polyacrylamide is "grafted through" chitosan soft substrates. The mechanism of grafting leads to ordered arrays of filament-like nanostructures spanning the chitosan-air interface. Additionally, the chemical composition of the filaments allows for post-chemical modification to change the physical properties of the filaments, and subsequently tailor surfaces for specific application. Unlike traditional materials, multi-functional or "smart" materials, such as binary polymer brushes (BPB) are capable of spontaneously changing the spatial distribution of functional groups and morphology at the surface upon external stimuli. Although promising in principle, the limited range of available complementary polymers with common non-selective solvents confines the diversity of usable materials and restricts any further advancement in the field. This dissertation also covers the fabrication and characterization of responsive nanoscale polystyrene templates or "mosaic" brushes that are capable of changing interfacial composition upon exposure to varying solvent qualities. Using a "mosaic" brush template is a unique approach that allows the fabrication of strongly immiscible polymer BPB without the need for a common solvent. The synthesis of such BPB is exemplified by two strongly immiscible polymers, i.e. polystyrene (polar) and polyacrylamide (non-polar), where polyacrylamide brush is "graft through" a Si-substrate modified with the polystyrene collapsed "mosaic" brush. The surface exhibits solvent-triggered responses, as well as application potential for anti-biofouling.

  11. Electrodynamic Tethers and E-Sails as Active Experiment Testbeds and Technologies in Space

    Science.gov (United States)

    Gilchrist, B. E.; Wiegmann, B.; Johnson, L.; Bilen, S. G.; Habash Krause, L.; Miars, G.; Leon, O.

    2017-12-01

    The use of small-to-large flexible structures in space such as tethers continues to be studied for scientific and technology applications. Here we will consider tether electrodynamic and electrostatic interactions with magneto-plasmas in ionospheres, magnetospheres, and interplanetary space. These systems are enabling fundamental studies of basic plasma physics phenomena, allowing direct studies of the space environment, and generating technological applications beneficial for science missions. Electrodynamic tethers can drive current through the tether based on the Lorenz force adding or extracting energy from its orbit allowing for the study of charged bodies or plasma plumes moving through meso-sonic magnetoplasmas [1]. Technologically, this also generates propulsive forces requiring no propellant and little or no consumables in any planetary system with a magnetic field and ionosphere, e.g., Jupiter [2]. Further, so called electric sails (E-sails) are being studied to provide thrust through momentum exchange with the hypersonic solar wind. The E-sail uses multiple, very long (10s of km) charged, mostly bare rotating conducting tethers to deflect solar wind protons. It is estimated that a spacecraft could achieve a velocity over 100 km/s with time [3,4]. 1. Banks, P.M., "Review of electrodynamic tethers for space plasma science," J. Spacecraft and Rockets, vol. 26, no. 4, pp. 234-239, 1989. 2. Talley, C., J. Moore, D. Gallagher, and L. Johnson, "Propulsion and power from a rotating electrodynamic tether at Jupiter," 38th AIAA Aerospace Sciences Meeting and Exhibit, January 2000. 3. Janhunen, P., "The electric sail—A new propulsion method which may enable fast missions to the outer solar system," J. British Interpl. Soc., vol. 61, no. 8, pp. 322-325, 2008. 4. Wiegman, B., T. Scheider, A. Heaton, J. Vaughn, N. Stone, and K. Wright, "The Heliopause Electrostatic Rapid Transit System (HERTS)—Design, trades, and analyses performed in a two-year NASA investigation

  12. A Nanosecond Pulsed Plasma Brush for Surface Decontamination

    Science.gov (United States)

    Neuber, Johanna; Malik, Muhammad; Song, Shutong; Jiang, Chunqi

    2015-11-01

    This work optimizes a non-thermal, atmospheric pressure plasma brush for surface decontamination. The generated plasma plumes with a maximum length of 2 cm are arranged in a 5 cm long, brush-like array. The plasma was generated in ambient air with Acinetobacter baumannii. Laminate surfaces inoculated with over-night cultured bacteria were subject to the plasma treatment for varying water concentrations in He, flow rates and discharge voltages. It was found that increasing the water content of the feed gas greatly enhanced the bactericidal effect. Emission spectroscopy was performed to identify the reactive plasma species that contribute to this variation. Additional affiliation: Frank Reidy Research Center for Bioelectrics

  13. Tethered Aerostat Effects on Nearby Seismometers

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-12-01

    This report assesses seismic interference generated by a tethered aerostat. The study was motivated by a planned aerostat deployment within the footprint of the Dry Alluvium Geology seismic network. No evidence was found for seismic interference generated by the aerostat, and thus the e ects on the Dry Alluvium Geology sensors will be negligible.

  14. Molecular dynamics simulations of polyelectrolyte brushes under poor solvent conditions: origins of bundle formation.

    Science.gov (United States)

    He, Gui-Li; Merlitz, Holger; Sommer, Jens-Uwe

    2014-03-14

    Molecular dynamics simulations are applied to investigate salt-free planar polyelectrolyte brushes under poor solvent conditions. Starting above the Θ-point with a homogeneous brush and then gradually reducing the temperature, the polymers initially display a lateral structure formation, forming vertical bundles of chains. A further reduction of the temperature (or solvent quality) leads to a vertical collapse of the brush. By varying the size and selectivity of the counterions, we show that lateral structure formation persists and therefore demonstrate that the entropy of counterions being the dominant factor for the formation of the bundle phase. By applying an external compression force on the brush we calculate the minimal work done on the polymer phase only and prove that the entropy gain of counterions in the bundle state, as compared to the homogeneously collapsed state at the same temperature, is responsible for the lateral microphase segregation. As a consequence, the observed lateral structure formation has to be regarded universal for osmotic polymer brushes below the Θ-point.

  15. Changes to Glazed Dental Ceramic Shade, Roughness, and Microhardness after Bleaching and Simulated Brushing.

    Science.gov (United States)

    Rodrigues, Carlos Roberto Teixeira; Turssi, Cecilia Pedroso; Amaral, Flávia Lucisano Botelho; Basting, Roberta Tarkany; França, Fabiana Mantovani Gomes

    2017-09-05

    To evaluate shade stability, surface roughness, microhardness, and compressive strength of a glazed feldspathic ceramic subjected to bleaching and simulated brushing. Eighty-eight glazed feldspathic ceramic specimens were made from microparticulate leucite and divided into eight groups (n = 10). The whitening products used were: Opalescence Trèswhite Supreme (Ultradent), Opalescence®\\ PF 15% (Ultradent), and Oral-B 3D White Whitestrips. All substances for whitening were used for 4 hours/day for a period of 14 days; the control group was not bleached. Next, half of the specimens were individually brushed. Microhardness and surface roughness data were subjected to three-way ANOVA and Tukey test. The diametrical tensile strength data were subjected to two-way ANOVA. The shade change data were analyzed using Kruskal-Wallis, Mann-Whitney, and the Student-Newman-Keuls test. The significance level was set at 5%. Glazed feldspathic ceramic surface microhardness was significantly affected by bleaching agents (p = 0.007). Initially, glazed ceramic microhardness was significantly higher than that observed after contact with the bleaching agents, whether or not brushing was performed. The specimens submitted to bleaching in preloaded trays presented lower surface roughness values after brushing (p = 0.037). The surface roughness was significantly lower in the brushed specimens (p = 0.044). The diametrical tensile strength was not significantly affected by the application of bleaching agents (p = 0.563) or by brushing (p = 0.477). When the specimens were brushed, however, shade change was significantly influenced by the bleaching agent used (p = 0.041). Bleaching agents associated with brushing cycles can alter surface properties and shade stability of glazed feldspathic ceramics, though such findings may not reflect the performance of unglazed feldspathic ceramics. © 2017 by the American College of Prosthodontists.

  16. 21 CFR 884.1100 - Endometrial brush.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endometrial brush. 884.1100 Section 884.1100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL...) Indication: Only to evaluate the endometrium, and (ii) Contraindications: Pregnancy, history of uterine...

  17. Template-directed ligation of tethered mononucleotides by t4 DNA ligase for kinase ribozyme selection.

    Directory of Open Access Journals (Sweden)

    David G Nickens

    Full Text Available BACKGROUND: In vitro selection of kinase ribozymes for small molecule metabolites, such as free nucleosides, will require partition systems that discriminate active from inactive RNA species. While nucleic acid catalysis of phosphoryl transfer is well established for phosphorylation of 5' or 2' OH of oligonucleotide substrates, phosphorylation of diffusible small molecules has not been demonstrated. METHODOLOGY/PRINCIPAL FINDINGS: This study demonstrates the ability of T4 DNA ligase to capture RNA strands in which a tethered monodeoxynucleoside has acquired a 5' phosphate. The ligation reaction therefore mimics the partition step of a selection for nucleoside kinase (deoxyribozymes. Ligation with tethered substrates was considerably slower than with nicked, fully duplex DNA, even though the deoxynucleotides at the ligation junction were Watson-Crick base paired in the tethered substrate. Ligation increased markedly when the bridging template strand contained unpaired spacer nucleotides across from the flexible tether, according to the trends: A(2>A(1>A(3>A(4>A(0>A(6>A(8>A(10 and T(2>T(3>T(4>T(6 approximately T(1>T(8>T(10. Bridging T's generally gave higher yield of ligated product than bridging A's. ATP concentrations above 33 microM accumulated adenylated intermediate and decreased yields of the gap-sealed product, likely due to re-adenylation of dissociated enzyme. Under optimized conditions, T4 DNA ligase efficiently (>90% joined a correctly paired, or TratioG wobble-paired, substrate on the 3' side of the ligation junction while discriminating approximately 100-fold against most mispaired substrates. Tethered dC and dG gave the highest ligation rates and yields, followed by tethered deoxyinosine (dI and dT, with the slowest reactions for tethered dA. The same kinetic trends were observed in ligase-mediated capture in complex reaction mixtures with multiple substrates. The "universal" analog 5-nitroindole (dNI did not support ligation when

  18. Friction Properties of Carbon Fiber Brush

    OpenAIRE

    大塚, 由佳; 月山, 陽介; 野老山, 貴行; 梅原, 徳次; OHTSUKA, Yuka; TSUKIYAMA, Yosuke; TOKOROYAMA, Takayuki; UMEHARA, Noritsugu

    2011-01-01

    直径数μmのカーボンファイバーを束ねたカーボンファイバーブラシ材料と金属材料のすべり摩擦におけるすべり出しの摩擦及び平均摩擦特性と,金属同士のそれらの摩擦特性の相違を調べ,カーボンファイバーブラシ材料の摩擦の特異性を明らかにした. Friction properties as initial and average friction coefficient were investigated for carbon brush materials. Experimental results shows that static friction coefficient of carbon fiber brush is smaller than kinetic friction after a macro slip. This phenomena is different from the usual friction properties between metals. I...

  19. STICS: surface-tethered iterative carbohydrate synthesis.

    Science.gov (United States)

    Pornsuriyasak, Papapida; Ranade, Sneha C; Li, Aixiao; Parlato, M Cristina; Sims, Charles R; Shulga, Olga V; Stine, Keith J; Demchenko, Alexei V

    2009-04-14

    A new surface-tethered iterative carbohydrate synthesis (STICS) technology is presented in which a surface functionalized 'stick' made of chemically stable high surface area porous gold allows one to perform cost efficient and simple synthesis of oligosaccharide chains; at the end of the synthesis, the oligosaccharide can be cleaved off and the stick reused for subsequent syntheses.

  20. Hierarchical Structure in Semicrystalline Polymers Tethered to Nanospheres

    KAUST Repository

    Kim, Sung A; Archer, Lynden A.

    2014-01-01

    We report on structural and dynamic transitions of polymers tethered to nanoparticles. In particular, we use X-ray diffraction, vibrational spectroscopy, and thermal measurements to investigate multiscale structure and dynamic transitions of poly

  1. Biomechanical simulations of costo-vertebral and anterior vertebral body tethers for the fusionless treatment of pediatric scoliosis.

    Science.gov (United States)

    Aubin, Carl-Éric; Clin, Julien; Rawlinson, Jeremy

    2018-01-01

    Compression-based fusionless tethers are an alternative to conventional surgical treatments of pediatric scoliosis. Anterior approaches place an anterior (ANT) tether on the anterolateral convexity of the deformed spine to modify growth. Posterior, or costo-vertebral (CV), approaches have not been assessed for biomechanical and corrective effectiveness. The objective was to biomechanically assess CV and ANT tethers using six patient-specific, finite element models of adolescent scoliotic patients (11.9 ± 0.7 years, Cobb 34° ± 10°). A validated algorithm simulated the growth and Hueter-Volkmann growth modulation over a period of 2 years with the CV and ANT tethers at two initial tensions (100, 200 N). The models without tethering also simulated deformity progression with Cobb angle increasing from 34° to 56°, axial rotation 11° to 13°, and kyphosis 28° to 32° (mean values). With the CV tether, the Cobb angle was reduced to 27° and 20° for tensions of 100 and 200 N, respectively, kyphosis to 21° and 19°, and no change in axial rotation. With the ANT tether, Cobb was reduced to 32° and 9° for 100 and 200 N, respectively, kyphosis unchanged, and axial rotation to 3° and 0°. While the CV tether mildly corrected the coronal curve over a 2-year growth period, it had sagittal lordosing effect, particularly with increasing initial axial rotation (>15°). The ANT tether achieved coronal correction, maintained kyphosis, and reduced the axial rotation, but over-correction was simulated at higher initial tensions. This biomechanical study captured the differences between a CV and ANT tether and indicated the variability arising from the patient-specific characteristics. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:254-264, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Manipulating neuronal circuits with endogenous and recombinant cell-surface tethered modulators

    Directory of Open Access Journals (Sweden)

    Mandë Holford

    2009-10-01

    Full Text Available Neuronal circuits depend on the precise regulation of cell-surface receptors and ion channels. An ongoing challenge in neuroscience research is deciphering the functional contribution of specific receptors and ion channels using engineered modulators. A novel strategy, termed “tethered toxins”, was recently developed to characterize neuronal circuits using the evolutionary derived selectivity of venom peptide toxins and endogenous peptide ligands, such as lynx1 prototoxins. Herein, the discovery and engineering of cell-surface tethered peptides is reviewed, with particular attention given to their cell-autonomy, modular composition, and genetic targeting in different model organisms. The relative ease with which tethered peptides can be engineered, coupled with the increasing number of neuroactive venom toxins and ligand peptides being discovered, imply a multitude of potentially innovative applications for manipulating neuronal circuits and tissue-specific cell networks, including treatment of disorders caused by malfunction of receptors and ion channels.

  3. Characterization of swollen structure of high-density polyelectrolyte brushes in salt solution by neutron reflectivity

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Motoyasu; Takahara, Atsushi [Institute for Materials Chemistry and Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Terayama, Yuki [Graduate School of Engineering, Kyushu University (Japan); Hino, Masahiro [Reactor Research Institute, Kyoto University (Japan); Ishihara, Kazuhiko, E-mail: takahara@cstf.kyushu-u.ac.j [Graduate School of Engineering, University of Tokyo (Japan)

    2009-08-01

    Zwitterionic and cationic polyelectrolyte brushes on quartz substrate were prepared by surface-initiated atom transfer radical polymerization of 2-(methacryloyloxy)ethyl phosphorylcholine (MPC) and 2-(methacryloyloxy)ethyltrimethylammonium chloride (METAC), respectively. The effects of ionic strength on brush structure and surface properties of densely grafted polyelectrolyte brushes were analysed by neutron reflectivity (NR) measurements. NR at poly(METAC)/D{sub 2}O and poly(MPC)/D{sub 2}O interface revealed that the grafted polymer chains were fairly extended from the substrate surface, while the thickness reduction of poly(METAC) brush was observed in 5.6 M NaCl/D{sub 2}O solution due to the screening of the repulsive interaction between polycations by hydrated salt ions. Interestingly, no structural change was observed in poly(MPC) brush even in a salt solution probably due to the unique interaction properties of phosphorylcholine units.

  4. Surface Grafted Glycopolymer Brushes to Enhance Selective Adhesion of HepG2 Cells

    DEFF Research Database (Denmark)

    Chernyy, Sergey; Jensen, Bettina Elisabeth Brøgger; Shimizu, Kyoko

    2013-01-01

    on the polymerization kinetics of 2-lactobionamidoethyl methacrylate) (LAMA) monomer on thermally oxidized silicon wafer. Both monolayer and multilayered aminosilane precursor layers have been prepared followed by reaction with 2-bromoisobutyrylbromide to form the ATRP initiator layer. It is inferred from the kinetic...... studies that the rate of termination is low on a multilayered initiator layer compared to a disordered monolayer structure. However both initiator types results in similar graft densities. Furthermore, it is shown that thick comb-like poly(LAMA) brushes can be constructed by initiating a second ATRP...... process on a previously formed poly(LAMA) brushes. The morphology of human hepatocellular carcinoma cancer cells (HepG2) on the comb-like poly(LAMA) brush layer has been studied. The fluorescent images of the HepG2 cells on the glycopolymer brush surface display distinct protrusions that extend outside...

  5. Anthrax in Vintage Animal-hair Shaving Brushes

    Centers for Disease Control (CDC) Podcasts

    2017-08-08

    Dr. Kate Hendricks, a CDC anthrax expert, discusses anthrax in vintage shaving brushes.  Created: 8/8/2017 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 8/8/2017.

  6. Position Control of an X4-Flyer Using a Tether

    Directory of Open Access Journals (Sweden)

    Yusuke Ouchi

    2016-05-01

    Full Text Available In Japan, aging of infrastructures, such as roads,bridges, and water and sewer services, etc. poses a problem, andit is required to extend the life-span of such infrastructures bymaintenance. Among infrastructures, especially bridges areperiodically inspected by short range visual observations, whichcheck the damage and deterioration of the surface. However,since there are some cases where the short range visualobservation is difficult, an alternative method is required so as toreplace the short range visual observation with it. So, "X4-Flyer"is very attractive because of realizing a movement at high altitudeeasily. The objective of this study is to develop a tethered X4-Flyer, so that the conventional short range visual observation ofbridges is replaced by it. In this paper, a method for themeasurement and control of the position is described by using atether for controlling the position of the X4-Flyer. In addition, itis checked whether the tethered X4-Flyer can control the positionusing the proposed method or not, letting it fly in a state in whicha tether is being attached

  7. Tethered elevator: A unique opportunity for space processing

    Science.gov (United States)

    Monti, R.

    1986-01-01

    The latest fluid dynamic and material science experiments in the microgravity environment have emphasized the importance of the residual gravity level and of the g-jitter on fluid physics phenomena. The tethered elevator presents the possibility of providing variable g-levels (both steady and g-jitter) around a very low steady g-level (that can be realized when the elevator is near the center of mass of the space station-tether complex). When positioning a variable periodic oscillation to the payload a clean g-jitter disturbance can be obtained that would not be otherwise obtainable by other systems. These two possibilities make the elevator a facility to help resolve a number of still open questions that are preventing wider utilization of the space environment in the microgravity area.

  8. Tethered Nanoparticle–Polymer Composites: Phase Stability and Curvature

    KAUST Repository

    Srivastava, Samanvaya; Agarwal, Praveen; Archer, Lynden A.

    2012-01-01

    different small-angle X-ray scattering signatures in comparison to phase-separated composites comprised of bare or sparsely grafted nanoparticles. A general diagram for the dispersion state and phase stability of polymer tethered nanoparticle-polymer

  9. Dynamics Model for a Multi-Tethered Space-Based Interferometer

    National Research Council Canada - National Science Library

    Gates, Stephen

    2000-01-01

    .... Tether constitutive behavior is discussed. Prescribed motion of any system degrees of freedom is treated, and expressions for the corresponding constraint force/torque components are established.

  10. Changes in intestinal absorption of nutrients and brush border glycoproteins after total parenteral nutrition in rats.

    Science.gov (United States)

    Miura, S; Tanaka, S; Yoshioka, M; Serizawa, H; Tashiro, H; Shiozaki, H; Imaeda, H; Tsuchiya, M

    1992-01-01

    The effect of total parenteral nutrition on nutrients absorption and glycoprotein changes of brush border membrane was examined in rat small intestine. In total parenteral nutrition rats, a marked decrease in activity of brush border enzymes was observed mainly in the proximal and middle segments of the intestine. Galactose perfusion of jejunal segment showed that hexose absorption was significantly inhibited, while intestinal absorption of glycine or dipeptide, glycylglycine was not significantly affected by total parenteral nutrition treatment. When brush border membrane glycoprotein profile was examined by [3H]-glucosamine or [3H]-fucose incorporation into jejunal loops, significant changes were observed in the glycoprotein pattern of brush border membrane especially in the high molecular weight range over 120 kDa after total parenteral nutrition treatment, suggesting strong dependency of glycoprotein synthesis on luminal substances. Molecular weight of sucrase isomaltase in brush border membrane detected by specific antibody showed no significant difference, however, in total parenteral nutrition and control rats. Also, molecular weight of specific sodium glucose cotransporter of intestinal brush border membrane detected by selective photoaffinity labelling was not altered in total parenteral nutrition rats. It may be that prolonged absence of oral food intake may produce significant biochemical changes in brush border membrane glycoprotein and absorptive capacity of small intestine, but these changes were not observed in all brush border membrane glycoproteins. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:1582592

  11. Obstructive jaundice: a comparative study of forceps and brush biopsy under percutaneous transhepatic cholangiography

    International Nuclear Information System (INIS)

    Li Yongdong; Han Xinwei; Wu Gang; Ma Bo; Xing Gusheng

    2004-01-01

    Objective: To compare the sensitivity between forceps biopsy and brushing, and to explore a feasible approach to pathological diagnosis of the obstructive jaundice. Methods: 92 consecutive patients with obstructive jaundice underwent transluminal forceps biopsy and brushing during percutaneous transhepatic cholangiography and percutaneous transhepatic cholangiodrainage. The technique was performed through a preexisting percutaneous transhepatic tract with multiple specimens obtained after passing the forceps biopsy or brush into a 8-French sheath. Finally the specimens were fixed with formalin for pathologic or cytologic diagnosis. Results: The histopathologic diagnosis was acquired in 81 out of 92 patients with forceps biopsy reaching the successful rate of 97.83%. Sensitivity of forceps biopsy in 92 patients was higher than that of brush in 84 patients (88.04% vs 76.19% χ 2 =4.251, P= <0.05). Conclusions: Percutaneous transhepatic cholangiobiopsy is a simple technique with minimal invasion, high sensitivity and worthy to be used spread extensively. Percutaneous transluminal brush cytology is also an useful method for establishing a diagnosis of cholangiocarcinoma. (authors)

  12. The Effect of Machining Conditions on the Forces in the Process of Roller Brush Machining

    Directory of Open Access Journals (Sweden)

    Jakub Matuszak

    2017-12-01

    Full Text Available Because of its advantages, brushing processing has many uses. The main ones include the removal of corrosion products, surface cleaning, deburring and shaping the properties of the surface layer. The intensity of these processes depends on the degree of impact of brush fibres on the work surface. In the case of tools, in which the resilient fibres are the working elements, forces in the brushing process, apart from the machining parameters, depend on the characteristics and overall dimensions of individual fibres. The paper presents the results of studies of the influence of technological parameters and type of fibres on the radial force in the brushing process.

  13. Self-consistent field theory of protein adsorption in a non-Gaussian polyelectrolyte brush

    NARCIS (Netherlands)

    Biesheuvel, P.M.; Leermakers, F.A.M.; Stuart, M.A.C.

    2006-01-01

    To describe adsorption of globular protein molecules in a polyelectrolyte brush we use the strong-stretching approximation of the Edwards self-consistent field equation, combined with corrections for a non-Gaussian brush. To describe chemical potentials in this mixture of (globular) species of

  14. Ionic-Liquid-Tethered Nanoparticles: Hybrid Electrolytes

    KAUST Repository

    Moganty, Surya S.

    2010-10-22

    A new class of solventless electrolytes was created by tethering ionic liquids to hard inorganic ZrO2 nanostructures (see picture; NIM=nanoscale ionic material). These hybrid fluids exhibit exceptional redox stability windows, excellent thermal stability, good lithium transference numbers, long-term interfacial stability in the presence of a lithium anode and, when doped with lithium salt, reasonable ionic conductivities.

  15. A Dual-Functional [SBA-15/Fe3O4/P(N-iPAAm] Hybrid System as a Potential Nanoplatform for Biomedical Application

    Directory of Open Access Journals (Sweden)

    Andreza de Sousa

    2014-01-01

    Full Text Available The synthesis strategy of a multifunctional system of [SBA-15/Fe3O4/P(N-iPAAm] hybrids of interest for bioapplications was explored. Magnetite nanoparticles coated by mesoporous silica were prepared by an alternative chemical route using neutral surfactant and without the application of any functionalization method. Monomer adsorption followed by in situ polymerization initiated by a radical was the adopted procedure to incorporate the hydrogel into the pore channels of silica nanocomposite. Characterization of the materials was carried out by using X-ray diffraction (XRD, Fourier-transform infrared spectroscopy (FTIR, N2 adsorption, transmission electron microscopy (TEM, and Temperature programmed reduction studies (TPR. Their application as drug delivery system using atenolol as a model drug to assess the influence of the application of low frequency alternating magnetic fields on drug release was evaluated. The structural characteristics of the magnetic hybrid nanocomposite, including the effect of the swelling behavior on heating by the application of an alternating magnetic field, are presented and discussed.

  16. System Dynamics and Feedforward Control for Tether-Net Space Robot System

    Directory of Open Access Journals (Sweden)

    Guang Zhai

    2009-06-01

    Full Text Available A new concept using flexible tether-net system to capture space debris is presented in this paper. With a mass point assumption the tether-net system dynamic model is established in orbital frame by applying Lagrange Equations. In order to investigate the net in-plane trajectories during after cast, the non-control R-bar and V-bar captures are simulated with ignoring the out-of-plane libration, the effect of in-plane libration on the trajectories of the capture net is demonstrated by simulation results. With an effort to damp the in-plane libration, the control scheme based on tether tension is investigated firstly, after that an integrated control scheme is proposed by introduced the thrusters into the system, the nonlinear close-loop dynamics is linearised by feedforward strategy, the simulation results show that feedforward controllor is effective for in-plane libration damping and enable the capture net to track an expected trajectory.

  17. Development of plastic elongation in nanocrystalline and amorphous Ni–W dual phase alloys by brushing technique

    International Nuclear Information System (INIS)

    Nakayama, S.; Adachi, H.; Yamasaki, T.

    2015-01-01

    Highlights: • A novel agitation technique called the brushing technique is proposed. • A homogeneous material can be obtained with the brushing technique. • The brushed material exhibits large plastic elongation with work hardening. - Abstract: A novel agitation technique, referred to as the “brushing technique” is proposed to treat the surface of a Ni–W alloy film during electrodeposition. This technique was developed to directly remove hydrogen bubbles on the film surface and to apply Ni ions to the interfacial layer with the substrate. The intrinsic mechanical properties of the Ni–W electrodeposits are then evaluated with respect to application. High resolution transmission electron microscopy observations revealed that both treated and untreated films have nanocrystallites of approximately 5 nm in diameter and an amorphous phase. There was a compositional difference of about. 1.4 at% W between the face side and the reverse side of the film that was not subjected to the brushing technique, whereas this difference was absent in the film subjected to the brushing technique. In addition, the brushing technique reduced the surface roughness of the film and decreased the number of defects. As a result, a large plastic strain of about. 2.9% was observed with work hardening under tensile testing

  18. Interfacial Friction and Adhesion of Polymer Brushes

    KAUST Repository

    Landherr, Lucas J. T.; Cohen, Claude; Agarwal, Praveen; Archer, Lynden A.

    2011-01-01

    higher molar mass chains exhibit higher friction forces than those created using lower molar mass polymers. Increased grafting density of chains in the brush significantly reduces the COF by creating a uniform surface of stretched chains with a decreased

  19. RAFT-mediated synthesis of cationic poly[(ar-vinylbenzyl)trimethylammonium chloride] brushes for quantitative DNA immobilization

    International Nuclear Information System (INIS)

    Demirci, Serkan; Caykara, Tuncer

    2013-01-01

    The synthesis of cationic poly[(ar-vinylbenzyl)trimethylammonium chloride)] [poly(VBTAC)] brushes was achieved via reversible addition-fragmentation chain transfer (RAFT) polymerization and used for quantitative DNA immobilization. Initially, silicon surfaces were modified with RAFT chain transfer agent by utilizing an amide reaction involving a silicon wafer modified with allylamine and 4-cyanopentanoic acid dithiobenzoate (CPAD). Poly(VBTAC) brushes were then prepared via RAFT-mediated polymerization from the surface immobilized CPAD. Various characterization techniques including ellipsometry, X-ray photoelectron spectroscopy, grazing angle-Fourier transform infrared spectroscopy, atomic force microscopy and contact-angle goniometer were used to characterize the immobilization of CPAD on the silicon wafer and the subsequent polymer formation. The addition of free CPAD was required for the formation of well-defined polymer brushes, which subsequently resulted in the presence of free polymer chains in solution. The free polymer chains were isolated and used to estimate the molecular weights and polydispersity index of chains attached to the surface. Moreover, from atomic force microscopy and ellipsometry measurements, it was also determined that the density of immobilized DNA on the cationic poly(VBTAC) brushes can be quantitatively controlled by adjusting the solution concentration. Highlights: ► The cationic poly(VBTAC) brushes were prepared by RAFT polymerization. ► Grafting density of cationic poly(VBTAC) brushes was as high as 0.76 chains/nm 2 . ► The cationic poly(VBTAC) brushes were used for quantitative DNA immobilization.

  20. Intestinal alkaline phosphatase: selective endocytosis from the enterocyte brush border during fat absorption

    DEFF Research Database (Denmark)

    Hansen, Gert Helge; Niels-Christiansen, Lise-Lotte; Immerdal, Lissi

    2007-01-01

    explants. By immunofluorescence microscopy, fat absorption caused a translocation of IAP from the enterocyte brush border to the interior of the cell, whereas other brush-border enzymes were unaffected. By electron microscopy, the translocation occurred by a rapid (5 min) induction of endocytosis via...

  1. Application of the NASCAP Spacecraft Simulation Tool to Investigate Electrodynamic Tether Current Collection in LEO

    Science.gov (United States)

    Adams, Mitzi; HabashKrause, Linda

    2012-01-01

    Recent interest in using electrodynamic tethers (EDTs) for orbital maneuvering in Low Earth Orbit (LEO) has prompted the development of the Marshall ElectroDynamic Tether Orbit Propagator (MEDTOP) model. The model is comprised of several modules which address various aspects of EDT propulsion, including calculation of state vectors using a standard orbit propagator (e.g., J2), an atmospheric drag model, realistic ionospheric and magnetic field models, space weather effects, and tether librations. The natural electromotive force (EMF) attained during a radially-aligned conductive tether results in electrons flowing down the tether and accumulating on the lower-altitude spacecraft. The energy that drives this EMF is sourced from the orbital energy of the system; thus, EDTs are often proposed as de-orbiting systems. However, when the current is reversed using satellite charged particle sources, then propulsion is possible. One of the most difficult challenges of the modeling effort is to ascertain the equivalent circuit between the spacecraft and the ionospheric plasma. The present study investigates the use of the NASA Charging Analyzer Program (NASCAP) to calculate currents to and from the tethered satellites and the ionospheric plasma. NASCAP is a sophisticated set of computational tools to model the surface charging of three-dimensional (3D) spacecraft surfaces in a time-varying space environment. The model's surface is tessellated into a collection of facets, and NASCAP calculates currents and potentials for each one. Additionally, NASCAP provides for the construction of one or more nested grids to calculate space potential and time-varying electric fields. This provides for the capability to track individual particles orbits, to model charged particle wakes, and to incorporate external charged particle sources. With this study, we have developed a model of calculating currents incident onto an electrodynamic tethered satellite system, and first results are shown

  2. Long distance cell communication using spherical tether balloons

    Science.gov (United States)

    Manchanda, R. K.; Rajagopalan, Vasudevan; Vasudevan, Rajagopalan; Mehrotra, R. K.; Sreenivasan, S.; Pawaskar, M.; Subba Rao Jonnalagadda, Venkata; Buduru, Suneelkumar; Kulkarni, P. M.

    A proof-of-concept experiment was conducted for long-range cell communication for rural tele-phony and internet. We designed and fabricated a spherical tether balloon to carry the con-ventional micro base transceiver station (BTS) along with three slotted antenna to cover 2-pi radius. AC power and optical fiber were anchored along with the tether line. A special fre-quency license was obtained from Wireless Planning Commission (WPC) wing of Department of Telecommunication (DoT), India for the period of experiment so as not to affect the opera-tional networks. The experiments were carried out for different BTS heights up to 500 meter. Signal measurement both in data mode and voice quality were done in different quadrant using mobile vans. This paper describes the methodology (under patenting) and utility of technique for operational application.

  3. Effects of carbon brush anode size and loading on microbial fuel cell performance in batch and continuous mode

    KAUST Repository

    Lanas, Vanessa; Ahn, Yongtae; Logan, Bruce E.

    2014-01-01

    Larger scale microbial fuel cells (MFCs) require compact architectures to efficiently treat wastewater. We examined how anode-brush diameter, number of anodes, and electrode spacing affected the performance of the MFCs operated in fed-batch and continuous flow mode. All anodes were initially tested with the brush core set at the same distance from the cathode. In fed-batch mode, the configuration with three larger brushes (25 mm diameter) produced 80% more power (1240 mW m-2) than reactors with eight smaller brushes (8 mm) (690 mW m-2). The higher power production by the larger brushes was due to more negative and stable anode potentials than the smaller brushes. The same general result was obtained in continuous flow operation, although power densities were reduced. However, by moving the center of the smaller brushes closer to the cathode (from 16.5 to 8 mm), power substantially increased from 690 to 1030 mW m-2 in fed batch mode. In continuous flow mode, power increased from 280 to 1020 mW m-2, resulting in more power production from the smaller brushes than the larger brushes (540 mW m-2). These results show that multi-electrode MFCs can be optimized by selecting smaller anodes, placed as close as possible to the cathode. © 2013 Elsevier B.V. All rights reserved.

  4. Effects of carbon brush anode size and loading on microbial fuel cell performance in batch and continuous mode

    KAUST Repository

    Lanas, Vanessa

    2014-02-01

    Larger scale microbial fuel cells (MFCs) require compact architectures to efficiently treat wastewater. We examined how anode-brush diameter, number of anodes, and electrode spacing affected the performance of the MFCs operated in fed-batch and continuous flow mode. All anodes were initially tested with the brush core set at the same distance from the cathode. In fed-batch mode, the configuration with three larger brushes (25 mm diameter) produced 80% more power (1240 mW m-2) than reactors with eight smaller brushes (8 mm) (690 mW m-2). The higher power production by the larger brushes was due to more negative and stable anode potentials than the smaller brushes. The same general result was obtained in continuous flow operation, although power densities were reduced. However, by moving the center of the smaller brushes closer to the cathode (from 16.5 to 8 mm), power substantially increased from 690 to 1030 mW m-2 in fed batch mode. In continuous flow mode, power increased from 280 to 1020 mW m-2, resulting in more power production from the smaller brushes than the larger brushes (540 mW m-2). These results show that multi-electrode MFCs can be optimized by selecting smaller anodes, placed as close as possible to the cathode. © 2013 Elsevier B.V. All rights reserved.

  5. Surface interaction forces of cellulose nanocrystals grafted with thermoresponsive polymer brushes.

    Science.gov (United States)

    Zoppe, Justin O; Osterberg, Monika; Venditti, Richard A; Laine, Janne; Rojas, Orlando J

    2011-07-11

    The colloidal stability and thermoresponsive behavior of poly(N-isopropylacrylamide) brushes grafted from cellulose nanocrystals (CNCs) of varying graft densities and molecular weights was investigated. Indication of the grafted polymer brushes was obtained after AFM imaging of CNCs adsorbed on silica. Also, aggregation of the nanoparticles carrying grafts of high degree of polymerization was observed. The responsiveness of grafted CNCs in aqueous dispersions and as an ultrathin film was evaluated by using light scattering, viscosimetry, and colloidal probe microscopy (CPM). Light transmittance measurements showed temperature-dependent aggregation originating from the different graft densities and molecular weights. The lower critical solution temperature (LCST) of grafted poly(NiPAAm) brushes was found to decrease with the ionic strength, as is the case for free poly(NiPAAm) in aqueous solution. Thermal responsive behavior of grafted CNCs in aqueous dispersions was observed by a sharp increase in dispersion viscosity as the temperature approached the LCST. CPM in liquid media for asymmetric systems consisting of ultrathin films of CNCs and a colloidal silica probe showed the distinctive effects of the grafted polymer brushes on interaction and adhesive forces. The origin of such forces was found to be mainly electrostatic and steric in the case of bare and grafted CNCs, respectively. A decrease in the onset of attractive and adhesion forces of grafted CNCs films were observed with the ionic strength of the aqueous solution. The decreased mobility of polymer brushes upon partial collapse and decreased availability of hydrogen bonding sites with higher electrolyte concentration were hypothesized as the main reasons for the less prominent polymer bridging between interacting surfaces.

  6. Tethered "kiteplane" design for the Laddermill project

    NARCIS (Netherlands)

    Breukels, J.; Ockels, W.

    2005-01-01

    The Laddermill is an innovative concept for generating energy from wind using large kite-like wings on a tether. The wings are able to fly in both the regime of airplanes and kites. We therefore call these structures "kiteplanes". By providing a recurring motion with a large lift during ascending

  7. Manufacturing of copper-graphite brushes for automobile applications

    International Nuclear Information System (INIS)

    Answar, M.Y.

    2006-01-01

    Copper-graphite brushes are used in high-volume automotive applications, such as ignition switches, window lifts, wiper motors, engine cooling fans, ABS break system and seat actuators etc. The amount of graphite in these brushes may range from 5 -20 wt. %. In this paper, some of the results of a study carried out using locally produced electrolytic copper powder and imported graphite powder are being summarized. The green compacts were produced by compaction at 650 MPa. These compacts were sintered at temperatures between 950 to 1050 degree C for various time intervals. The effects of sintering temperatures and time on the properties are analyzed. The influence of small additions of zinc on hardness of the sintered alloy compacts is also investigated. (author)

  8. Cross Sectional: bilateral parent-child interactions in school-age children's tooth-brushing behaviors.

    Science.gov (United States)

    Goh, Esther C L; Hsu, Stephen Chin-Ying

    2013-01-01

    The purpose of this study was to examine bilateral dynamics between parents and children in influencing children's tooth-brushing behaviors. In-depth conversational interviews-a specific qualitative method-were conducted with 38 parents in urban Xiamen, China and Singapore to learn insights into parental strategies for encouraging tooth-brushing habits in 6- to 9-year-old children. The interviews also examined the range of responses from children toward these parental strategies. Children usually do not comply with these tooth-brushing instructions from parents without a process of negotiation. Children's responses ranged from active resistant to compliant. Parents in Xiamen tended to use softer strategies and were more prone to be emotionally and behaviorally influenced by children's effort to thwart these strategies. Conversely, Singapore parents tended to demonstrate greater tenacity in negotiating with children. The process of developing children's tooth-brushing habits is not a unilateral from-parent-to-children process. Instead, it should be conceptualized as an ongoing interaction with bilateral power of influence from both parties.

  9. Novel Strategy for Photopatterning Emissive Polymer Brushes for Organic Light Emitting Diode Applications.

    Science.gov (United States)

    Page, Zachariah A; Narupai, Benjaporn; Pester, Christian W; Bou Zerdan, Raghida; Sokolov, Anatoliy; Laitar, David S; Mukhopadhyay, Sukrit; Sprague, Scott; McGrath, Alaina J; Kramer, John W; Trefonas, Peter; Hawker, Craig J

    2017-06-28

    A light-mediated methodology to grow patterned, emissive polymer brushes with micron feature resolution is reported and applied to organic light emitting diode (OLED) displays. Light is used for both initiator functionalization of indium tin oxide and subsequent atom transfer radical polymerization of methacrylate-based fluorescent and phosphorescent iridium monomers. The iridium centers play key roles in photocatalyzing and mediating polymer growth while also emitting light in the final OLED structure. The scope of the presented procedure enables the synthesis of a library of polymers with emissive colors spanning the visible spectrum where the dopant incorporation, position of brush growth, and brush thickness are readily controlled. The chain-ends of the polymer brushes remain intact, affording subsequent chain extension and formation of well-defined diblock architectures. This high level of structure and function control allows for the facile preparation of random ternary copolymers and red-green-blue arrays to yield white emission.

  10. Real-time x-ray scattering study of the initial growth of organic crystals on polymer brushes

    Energy Technology Data Exchange (ETDEWEB)

    An, Sung Yup; Ahn, Kwangseok; Kim, Doris Yangsoo; Lee, Dong Ryeol, E-mail: drlee@ssu.ac.kr [Department of Physics, Soongsil University, Seoul 156-743 (Korea, Republic of); Lee, Hyun-Hwi [Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Cho, Jeong Ho, E-mail: jhcho94@skku.edu [Department of Chemical Engineering, SKKU Advanced Institute of Nanotechnology (SAINT) and Center for Human Interface Nano Technology (HINT), Sungkyunkwan University, Suwon 440-476 (Korea, Republic of)

    2014-04-21

    We studied the early-stage growth structures of pentacene organic crystals grown on polymer brushes using real-time x-ray scattering techniques. In situ x-ray reflectivity and atomic force microscopy analyses revealed that at temperatures close to the glass transition temperature of polymer brush, the pentacene overlayer on a polymer brush film showed incomplete condensation and 3D island structures from the first monolayer. A growth model based on these observations was used to quantitatively analyze the real-time anti-Bragg x-ray scattering intensities measured during pentacene growth to obtain the time-dependent layer coverage of the individual pentacene monolayers. The extracted total coverage confirmed significant desorption and incomplete condensation in the pentacene films deposited on the polymer brushes. These effects are ascribed to the change in the surface viscoelasticity of the polymer brushes around the glass transition temperature.

  11. Hydrogel brushes grafted from stainless steel via surface-initiated atom transfer radical polymerization for marine antifouling

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jingjing, E-mail: jjwang1@hotmail.com; Wei, Jun

    2016-09-30

    Highlights: • Crosslinked hydrogel brushes were grafted from SS surfaces for marine antifouling. • All brush-coated SS surfaces could effectively reduce the adhesion of biofouling. • The antifouling efficacy increased with the crosslinking density of hydrogels. - Abstract: Crosslinked hydrogel brushes were grafted from stainless steel (SS) surfaces for marine antifouling. The brushes were prepared by surface-initiated atom transfer radical polymerization (SI-ATRP) of 2-methacryloyloxyethyl phosphorylcholine (MPC) and poly(ethylene glycol) methyl ether methacrylate (PEGMA) respectively with different fractions of crosslinker in the feed. The grafted layers prepared with different thickness were characterized by X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), ellipsometry and water contact angle measurements. With the increase in the fraction of crosslinker in the feed, the thickness of the grafted layer increased and the surface became smooth. All the brush-coated SS surfaces could effectively reduce the adhesion of bacteria and microalgae and settlement of barnacle cyprids, as compared to the pristine SS surface. The antifouling efficacy of the PEGMA polymer (PPEGMA)-grafted surface was higher than that of the MPC polymer (PMPC)-grafted surfaces. Furthermore, the crosslinked hydrogel brush-grafted surfaces exhibited better fouling resistance than the non-crosslinked polymer brush-grafted surfaces, and the antifouling efficacy increased with the crosslinking density. These hydrogel coatings of low toxicity and excellent anti-adhesive characteristics suggested their useful applications as environmentally friendly antifouling coatings.

  12. Hydrogel brushes grafted from stainless steel via surface-initiated atom transfer radical polymerization for marine antifouling

    International Nuclear Information System (INIS)

    Wang, Jingjing; Wei, Jun

    2016-01-01

    Highlights: • Crosslinked hydrogel brushes were grafted from SS surfaces for marine antifouling. • All brush-coated SS surfaces could effectively reduce the adhesion of biofouling. • The antifouling efficacy increased with the crosslinking density of hydrogels. - Abstract: Crosslinked hydrogel brushes were grafted from stainless steel (SS) surfaces for marine antifouling. The brushes were prepared by surface-initiated atom transfer radical polymerization (SI-ATRP) of 2-methacryloyloxyethyl phosphorylcholine (MPC) and poly(ethylene glycol) methyl ether methacrylate (PEGMA) respectively with different fractions of crosslinker in the feed. The grafted layers prepared with different thickness were characterized by X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), ellipsometry and water contact angle measurements. With the increase in the fraction of crosslinker in the feed, the thickness of the grafted layer increased and the surface became smooth. All the brush-coated SS surfaces could effectively reduce the adhesion of bacteria and microalgae and settlement of barnacle cyprids, as compared to the pristine SS surface. The antifouling efficacy of the PEGMA polymer (PPEGMA)-grafted surface was higher than that of the MPC polymer (PMPC)-grafted surfaces. Furthermore, the crosslinked hydrogel brush-grafted surfaces exhibited better fouling resistance than the non-crosslinked polymer brush-grafted surfaces, and the antifouling efficacy increased with the crosslinking density. These hydrogel coatings of low toxicity and excellent anti-adhesive characteristics suggested their useful applications as environmentally friendly antifouling coatings.

  13. Surface changes of enamel after brushing with charcoal toothpaste

    Science.gov (United States)

    Pertiwi, U. I.; Eriwati, Y. K.; Irawan, B.

    2017-08-01

    The aim of this study was to determine the surface roughness changes of tooth enamel after brushing with charcoal toothpaste. Thirty specimens were brushed using distilled water (the first group), Strong® Formula toothpaste (the second group), and Charcoal® Formula toothpaste for four minutes and 40 seconds (equivalent to one month) and for 14 minutes (equivalent to three months) using a soft fleece toothbrush with a mass of 150 gr. The roughness was measured using a surface roughness tester, and the results were tested with repeated ANOVA test and one-way ANOVA. The value of the surface roughness of tooth enamel was significantly different (penamel.

  14. Fast discharging homopolar drum-type generator with gas bearing and flexible copper-fiber brushes

    International Nuclear Information System (INIS)

    Kibardin, A.S.; Komin, A.V.; Sojkin, V.F.; Frolkin, V.I.

    1984-01-01

    The description and results of testing schock-excited homopolar generator (SEHG) with a drum-type rotor, a gas bearing and flexible copper-fiber brushes are presented. SEHG has a magnetic core with two excitation coils with the designed field of 1.8-2 T in the gap. The drum-type titanium rotor has 80 kg, is 0.5 m in diameter, 0.25 m length and 0.05 m thick. SEHG power is 3.6 MJ, overall dimensions are 0.8x1 m. Single- and double-row bearings, representing an aluminium shell of 15 mm thick, established inside an external backward current lead and isolated from it, are used to control serviceability of a radial gas-static bearing, which is a support for an SEHG rotor. The bearing surface was covered with the colloidal graphite and had one or two rows by 24 openings for swelling. Brush units represent a bronze brush ring, containing 44 copper-fiber brushes. Tests results confirm serviceability of copper-fiber brushes with quite large dimensions and permit to count on producing the 2.4 MA electric discharge and 12 ms pulse rise time

  15. The effect of food location, heat load, and intrusive medical procedures on brushing activity in dairy cows.

    Science.gov (United States)

    Mandel, R; Whay, H R; Nicol, C J; Klement, E

    2013-10-01

    Animals allocate time and effort to a range of core (e.g., sleeping, feeding, drinking) and "luxury" (e.g., playing, exploring) activities. A luxury activity is characterized by low resilience and, as such, will be reduced when time or energy resources are limited, including under conditions of stress or discomfort. One seemingly luxurious activity available to cows on an increasing number of dairy farms is rubbing against an automated brush. The current study examined the effect of distance from food, heat load, and an intrusive medical procedure (i.e., artificial insemination and transrectal pregnancy examination) on the resilience of brush usage. The probability of using the brush decreased significantly when food was located distantly from the brush (mean=0.53) compared with days when food was located closer to the brush (mean=0.81). Brush usage also decreased at high temperature and humidity levels, with an average decrease of 0.062 brushing events for an increase of 1 temperature-humidity index unit (95% confidence interval=-0.93-0.030). In addition, a significant reduction of approximately 50% in brushing activity was observed on days of artificial insemination compared with the preceding 3d and the following 3d. These findings show that brush usage is a low resilience activity that reduces under a range of conditions. It may thus have the potential to be used as an indicator of a range of health and welfare problems in cows. Further research should be conducted to assess the sensitivity and specificity of this suggested tool and its possible contribution to the early detection of morbidity. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Tooth brushing among 11- to 15-year-olds in Denmark: combined effect of social class and migration status.

    Science.gov (United States)

    Bast, L S; Nordahl, H; Christensen, L B; Holstein, B E

    2015-03-01

    Regular tooth brushing in adolescence predicts stable tooth brushing habits later in life. Differences in tooth brushing habits by ethnic background and socioeconomic position have been suggested. We investigated migration status and social class in relation to infrequent tooth brushing both separately and combined. The study population was 11-15 year-olds chosen from a clustered random sample of schools. Univariate and multivariate logistic regression analyses estimated the separate and combined effects of migration status and social class on less than twice daily tooth brushing. 10,607 respondents: a response rate of 88.3%. Boys of lower social class had higher odds ratio (OR) of infrequent tooth brushing than girls: 1.98 (95% confidence interval 1.62-2.41) vs 1.80 (1.53-2.24). Immigrants and descendants had higher odds compared to adolescents of Danish origin: immigrant boys OR 1.39 (1.05-1.89), girls OR 1.92 (1.47-2.50); descendant boys OR 2.53 (1.97-3.27), girls OR 2.56 (2.02-3.35). Analyses of the combined effect of social class and migration status showed that the social gradient in tooth brushing habits observed among ethnic Danes cannot be found among groups of immigrants and descendants. The study shows that both non-Danish origin and low social class increases the risk of infrequent tooth brushing among school-aged children. The study calls for in depth analyses of the processes which influence young people's tooth brushing habits. Further, there is a need to strengthen the promotion of appropriate tooth brushing habits of minority and low social class youths.

  17. Measurement of calcium influx in tethered rings of rabbit aorta under tension

    International Nuclear Information System (INIS)

    Gleason, M.M.; Ratz, P.H.; Flaim, S.F.

    1985-01-01

    Calcium (Ca) influx in vascular smooth muscle is routinely measured in untethered preparations not under passive stretch, and Ca influx data are correlated with data for steady-state isometric tension obtained under parallel conditions from tethered preparations under passive stretch. The validity of this method was tested by simultaneous measurement of Ca influx and tension in tethered rings of rabbit thoracic aorta. Ca influx ( 45 Ca 3-min pulse) and tension were measured at 3 and 30 min after norepinephrine (NE) or KCl and under control (no agonist) conditions. Active tension was significantly altered by variations in passive tension. Ca influx was unaffected by passive tension under control, NE, or KCl conditions, and results were similar at 3 and 30 min. The results confirm the validity of correlating Ca influx data from untethered rings with steady-state contractile response data obtained from tethered rings under similar experimental conditions

  18. Amphiphilic brushes from metallo-supramolecular block copolymers

    NARCIS (Netherlands)

    Guillet, P.; Fustin, C.A.; Wouters, D.; Höppener, S.; Schubert, U.S.; Gohy, J.M.W.

    2009-01-01

    A novel strategy to control the formation of amphiphilic brushes from metallo-supramol. block copolymers is described. The investigated copolymer consists of a polystyrene block linked to a poly(ethylene oxide) one via a charged bis-terpyridine ruthenium(ii) complex (PS-[Ru]-PEO). The initial

  19. Interaction between two parallel plates covered with a polyelectrolyte brush layer in an electrolyte solution.

    Science.gov (United States)

    Ohshima, Hiroyuki

    An approximate analytic expression is derived for the interaction energy between two parallel plates covered with a polyelectrolyte brush layer in an electrolyte solution. The interaction energy has three components: electrostatic interaction energy between two brush layers before and after their contact, steric interaction energy between two brush layers after their contact, and the van der Waals interaction energy between the cores of the plates. It is shown that these three components are of the same order of magnitude and contribute equally to the total interaction energy between two polyelectrolyte-coated plates in an electrolyte solution. On the basis of Derjaguin's approximation, an approximate expression for the interaction energy between two spherical particles covered with polyelectrolyte brush layers is also derived.

  20. Differential Regulation of Synaptic Vesicle Tethering and Docking by UNC-18 and TOM-1.

    Science.gov (United States)

    Gracheva, Elena O; Maryon, Ed B; Berthelot-Grosjean, Martine; Richmond, Janet E

    2010-01-01

    The assembly of SNARE complexes between syntaxin, SNAP-25 and synaptobrevin is required to prime synaptic vesicles for fusion. Since Munc18 and tomosyn compete for syntaxin interactions, the interplay between these proteins is predicted to be important in regulating synaptic transmission. We explored this possibility, by examining genetic interactions between C. elegans unc-18(Munc18), unc-64(syntaxin) and tom-1(tomosyn). We have previously demonstrated that unc-18 mutants have reduced synaptic transmission, whereas tom-1 mutants exhibit enhanced release. Here we show that the unc-18 mutant release defect is associated with loss of two morphologically distinct vesicle pools; those tethered within 25 nm of the plasma membrane and those docked with the plasma membrane. In contrast, priming defective unc-13 mutants accumulate tethered vesicles, while docked vesicles are greatly reduced, indicating tethering is UNC-18-dependent and occurs in the absence of priming. C. elegans unc-64 mutants phenocopy unc-18 mutants, losing both tethered and docked vesicles, whereas overexpression of open syntaxin preferentially increases vesicle docking, suggesting UNC-18/closed syntaxin interactions are responsible for vesicle tethering. Given the competition between vertebrate tomosyn and Munc18, for syntaxin binding, we hypothesized that C. elegans TOM-1 may inhibit both UNC-18-dependent vesicle targeting steps. Consistent with this hypothesis, tom-1 mutants exhibit enhanced UNC-18 plasma membrane localization and a concomitant increase in both tethered and docked synaptic vesicles. Furthermore, in tom-1;unc-18 double mutants the docked, primed vesicle pool is preferentially rescued relative to unc-18 single mutants. Together these data provide evidence for the differential regulation of two vesicle targeting steps by UNC-18 and TOM-1 through competitive interactions with syntaxin.

  1. Differential regulation of synaptic vesicle tethering and docking by UNC-18 and TOM-1

    Directory of Open Access Journals (Sweden)

    Elena O Gracheva

    2010-10-01

    Full Text Available The assembly of SNARE complexes between syntaxin, SNAP-25 and synaptobrevin is required to prime synaptic vesicles for fusion. Since Munc18 and tomosyn compete for syntaxin interactions, the interplay between these proteins is predicted to be important in regulating synaptic transmission. We explored this possibility, by examining genetic interactions between C. elegans unc-18(Munc18, unc-64(syntaxin and tom-1(tomosyn. We have previously demonstrated that unc-18 mutants have reduced synaptic transmission, whereas tom-1 mutants exhibit enhanced release. Here we show that the unc-18 mutant release defect is associated with loss of two morphologically distinct vesicle pools; those tethered within 25nm of the plasma membrane and those docked with the plasma membrane. In contrast, priming defective unc-13 mutants accumulate tethered vesicles, while docked vesicles are greatly reduced, indicating tethering is UNC-18-dependent and occurs in the absence of priming. C. elegans unc-64 mutants phenocopy unc-18 mutants, losing both tethered and docked vesicles, whereas overexpression of open syntaxin preferentially increases vesicle docking, suggesting UNC-18/closed syntaxin interactions are responsible for vesicle tethering. Given the competition between vertebrate tomosyn and Munc18, for syntaxin binding, we hypothesized that C. elegans TOM-1 may inhibit both UNC-18-dependent vesicle targeting steps. Consistent with this hypothesis, tom-1 mutants exhibit enhanced UNC-18 plasma membrane localization and a concomitant increase in both tethered and docked synaptic vesicles. Furthermore, in tom-1;unc-18 double mutants the docked, primed vesicle pool is preferentially rescued relative to unc-18 single mutants. Together these data provide evidence for the differential regulation of two vesicle targeting steps by UNC-18 and TOM-1 through competitive interactions with syntaxin

  2. Acquisition of Ice-Tethered Profilers with Velocity (ITP-V) Instruments for Future Arctic Studies

    Science.gov (United States)

    2016-11-15

    San Diego, CA, IEEE Xplore . Toole, J. M., R. A. Krishfield, M.-L. Timmennans, and A. Proshutinsky, 2011: The Ice-Tethered Profiler: Argo ofthe Arctic, Oceanogr., 24, 126-135. 4 ...observations from Ice-Tethered Profilers, MTS/ IEEE Oceans’ 2015, Washington DC, 1-10. Krishfield, R., J. Toole, A. Proshutinsky, and M.-L. Timmennans, 2008

  3. Orbital Propagation of Momentum Exchange Tether Systems

    Science.gov (United States)

    Westerhoff, John

    2002-01-01

    An advanced concept in in-space transportation currently being studied is the Momentum-Exchange/Electrodynamic Reboost Tether System (MXER). The system acts as a large momentum wheel, imparting a Av to a payload in low earth orbit (LEO) at the expense of its own orbital energy. After throwing a payload, the system reboosts itself using an electrodynamic tether to push against Earth's magnetic field and brings itself back up to an operational orbit to prepare for the next payload. The ability to reboost itself allows for continued reuse of the system without the expenditure of propellants. Considering the cost of lifting propellant from the ,ground to LEO to do the same Av boost at $10000 per pound, the system cuts the launch cost of the payload dramatically, and subsequently, the MXER system pays for itself after a small number of missions.1 One of the technical hurdles to be overcome with the MXER concept is the rendezvous maneuver. The rendezvous window for the capture of the payload is on the order of a few seconds, as opposed to traditional docking maneuvers, which can take as long ets necessary to complete a precise docking. The payload, therefore, must be able to match its orbit to meet up with the capture device on the end of the tether at a specific time and location in the future. In order to be able to determine that location, the MXER system must be numerically propagated forward in time to predict where the capture device will be at that instant. It should be kept in mind that the propagation computation must be done faster than real-time. This study focuses on the efforts to find and/or build the tools necessary to numerically propagate the motion of the MXER system as accurately as possible.

  4. Space webs based on rotating tethered formations

    Science.gov (United States)

    Palmerini, Giovanni B.; Sgubini, Silvano; Sabatini, Marco

    2009-07-01

    Several on-going studies indicate the interest for large, light orbiting structures, shaped as fish nets or webs: along the ropes of the web small spacecraft can move like spiders to position and re-locate, at will, pieces of hardware devoted to specific missions. The concept could be considered as an intermediate solution between the large monolithic structure, heavy and expensive to realize, but easy to control, and the formations of satellites, where all system members are completely free and should manoeuvre in order to acquire a desired configuration. Instead, the advantage of having a "hard-but-light" link among the different grids lays in the partition of the tasks among system components and in a possible overall reduction of the control system complexity and cost. Unfortunately, there is no stable configuration for an orbiting, two-dimensional web made by light, flexible tethers which cannot support compression forces. A possible solution is to make use of centrifugal forces to pull the net, with a reduced number of simple thrusters located at the tips of the tethers to initially acquire the required spin. In this paper a dynamic analysis of a simplified rotating web is performed, in order to evaluate the spinning velocity able to satisfy the requirement for the stability of the system. The model adopted overlaps simpler elements, each of them given by a tether (made up of a number of linear finite elements) connecting two extreme bodies accommodating the spinning thrusters. The combination of these "diameter-like" elements provides the web, shaped according to the specific requirements. The net is primarily considered as subjected to Keplerian attraction and J2 and drag perturbations only, but its behaviour under thermal inputs is also investigated.

  5. A theoretical study of colloidal forces near an amphiphilic polymer brush

    Science.gov (United States)

    Wu, Jianzhong

    2011-03-01

    Polymer-based ``non-stick'' coatings are promising as the next generation of effective, environmentally-friendly marine antifouling systems that minimize nonspecific adsorption of extracellular polymeric substances (EPS). However, design and development of such systems are impeded by the poor knowledge of polymer-mediated interactions of biomacromolecules with the protected substrate. In this work, a polymer density functional theory (DFT) is used to predict the potential of mean force between spherical biomacromolecules and amphiphilic copolymer brushes within a coarse-grained model that captures essential nonspecific interactions such as the molecular excluded volume effects and the hydrophobic energies. The relevance of theoretical results for practical control of the EPS adsorption is discussed in terms of the efficiency of different brush configurations to prevent biofouling. It is shown that the most effective antifouling surface may be accomplished by using amphiphilic brushes with a long hydrophilic backbone and a hydrophobic end at moderate grafting density.

  6. The theory of reasoned action in describing tooth brushing, dental caries and diabetes adherence among diabetic patients.

    Science.gov (United States)

    Syrjälä, Anna-Maija H; Niskanen, Mirka C; Knuuttila, Matti L E

    2002-05-01

    Preventive oral health behaviour is important among diabetic patients, as it has been found that dental diseases and insulin-dependent diabetes mellitus (IDDM) have some psychological and biological factors in common. The aim here was to analyze the variables of Ajzen and Fishbein's theory of reasoned action to explain the reported frequency of tooth brushing, dental caries, HbA1c level and diabetes adherence. Cross-sectional data were gathered from 149 IDDM patients by means of a quantitative questionnaire, clinical examination and patient records. The results showed that a firmer intention to brush the teeth was related to a higher reported frequency of tooth brushing (p < 0.001). The attitude to and the subjective norm of tooth brushing were related to the intention to brush(p < 0.001) and to the reported frequency of tooth brushing. A better dental attitude was related to better diabetes adherence (p = 0.002) and fewer decayed surfaces (p = 0.01), and a firmer intention to brush the teeth was related to a lower HbA1c level (p = 0.015). Our results suggest that in oral health promotion among diabetic patients, both subjective norm and attitude are important and that diabetes adherence may be influenced by promoting dental attitude.

  7. Endocytic trafficking from the small intestinal brush border probed with FM dye

    DEFF Research Database (Denmark)

    Hansen, Gert H; Rasmussen, Karina; Niels-Christiansen, Lise-Lotte

    2009-01-01

    -linking galectins/intelectin, but little is known about the dynamic properties of this highly specialized membrane. Here, we probed the endocytic membrane trafficking from the brush border of organ cultured pig intestinal mucosal explants by use of a fixable, lipophilic FM dye. The fluorescent dye readily......, contributes to the overall permeability barrier of the gut. Key words: FM dye, small intestine, brush border, endocytosis....

  8. Cigarette smoking, tooth brushing characteristics, and perceived ...

    African Journals Online (AJOL)

    This study was conducted among four hundred non-dental undergraduates of University of Benin, Benin City, Nigeria to assess the prevalence of cigarette smoking, tooth brushing characteristics, perceived efficacy in oral self-care and preventing gingivodental diseases among them. The result showed that the perceived ...

  9. Drilling Deeper into tooth brushing skills: Is proactive interference an under-recognized factor in oral hygiene behavior change?

    Science.gov (United States)

    Thavarajah, Rooban; Kumar, Madan; Mohandoss, Anusa Arunachalam; Vernon, Lance T

    2015-09-01

    Proper tooth brushing is a seemingly simple motor activity that can promote oral health. Applying health theories, such as the Information-Motivation-Behavioral Skills (IMB) model, Motivational Interviewing (MI) and Integrated Health Coaching (IHC), may help optimize tooth brushing technique in those with suboptimal skills. Some motor activities, including tooth brushing, may over time become rote and unconscious actions, such that an existing habit can inhibit new learning, i.e., exert proactive interference on learning the new skill. Proactive interference may impede the acquisition of new tooth brushing skills; thus, in this report, we: (1) Review how the habit of tooth brushing is formed; (2) Postulate how proactive interference could impede the establishment of proper tooth brushing retraining; (3) Discuss the merits of this hypothesis; and (4) Provide guidance for future work in this topic within the context of an approach to behavior change that integrates IMB, MI and IHC methodology.

  10. A test for Creutzfeldt-Jakob disease using nasal brushings.

    Science.gov (United States)

    Orrú, Christina D; Bongianni, Matilde; Tonoli, Giovanni; Ferrari, Sergio; Hughson, Andrew G; Groveman, Bradley R; Fiorini, Michele; Pocchiari, Maurizio; Monaco, Salvatore; Caughey, Byron; Zanusso, Gianluigi

    2014-08-07

    Definite diagnosis of sporadic Creutzfeldt-Jakob disease in living patients remains a challenge. A test that detects the specific marker for Creutzfeldt-Jakob disease, the prion protein (PrP(CJD)), by means of real-time quaking-induced conversion (RT-QuIC) testing of cerebrospinal fluid has a sensitivity of 80 to 90% for the diagnosis of sporadic Creutzfeldt-Jakob disease. We have assessed the accuracy of RT-QuIC analysis of nasal brushings from olfactory epithelium in diagnosing sporadic Creutzfeldt-Jakob disease in living patients. We collected olfactory epithelium brushings and cerebrospinal fluid samples from patients with and patients without sporadic Creutzfeldt-Jakob disease and tested them using RT-QuIC, an ultrasensitive, multiwell plate-based fluorescence assay involving PrP(CJD)-seeded polymerization of recombinant PrP into amyloid fibrils. The RT-QuIC assays seeded with nasal brushings were positive in 30 of 31 patients with Creutzfeldt-Jakob disease (15 of 15 with definite sporadic Creutzfeldt-Jakob disease, 13 of 14 with probable sporadic Creutzfeldt-Jakob disease, and 2 of 2 with inherited Creutzfeldt-Jakob disease) but were negative in 43 of 43 patients without Creutzfeldt-Jakob disease, indicating a sensitivity of 97% (95% confidence interval [CI], 82 to 100) and specificity of 100% (95% CI, 90 to 100) for the detection of Creutzfeldt-Jakob disease. By comparison, testing of cerebrospinal fluid samples from the same group of patients had a sensitivity of 77% (95% CI, 57 to 89) and a specificity of 100% (95% CI, 90 to 100). Nasal brushings elicited stronger and faster RT-QuIC responses than cerebrospinal fluid (PCreutzfeldt-Jakob disease and indicated substantial prion seeding activity lining the nasal vault. (Funded by the Intramural Research Program of the National Institute of Allergy and Infectious Diseases and others.).

  11. A Test for Creutzfeldt–Jakob Disease Using Nasal Brushings

    Science.gov (United States)

    Orrú, Christina D.; Bongianni, Matilde; Tonoli, Giovanni; Ferrari, Sergio; Hughson, Andrew G.; Groveman, Bradley R.; Fiorini, Michele; Pocchiari, Maurizio; Monaco, Salvatore; Caughey, Byron; Zanusso, Gianluigi

    2014-01-01

    BACKGROUND Definite diagnosis of sporadic Creutzfeldt–Jakob disease in living patients remains a challenge. A test that detects the specific marker for Creutzfeldt–Jakob disease, the prion protein (PrPCJD), by means of real-time quaking-induced conversion (RT-QuIC) testing of cerebrospinal fluid has a sensitivity of 80 to 90% for the diagnosis of sporadic Creutzfeldt–Jakob disease. We have assessed the accuracy of RT-QuIC analysis of nasal brushings from olfactory epithelium in diagnosing sporadic Creutzfeldt– Jakob disease in living patients. METHODS We collected olfactory epithelium brushings and cerebrospinal fluid samples from patients with and patients without sporadic Creutzfeldt–Jakob disease and tested them using RT-QuIC, an ultrasensitive, multiwell plate–based fluorescence assay involving PrPCJD-seeded polymerization of recombinant PrP into amyloid fibrils. RESULTS The RT-QuIC assays seeded with nasal brushings were positive in 30 of 31 patients with Creutzfeldt–Jakob disease (15 of 15 with definite sporadic Creutzfeldt–Jakob disease, 13 of 14 with probable sporadic Creutzfeldt–Jakob disease, and 2 of 2 with inherited Creutzfeldt–Jakob disease) but were negative in 43 of 43 patients without Creutzfeldt–Jakob disease, indicating a sensitivity of 97% (95% confidence interval [CI], 82 to 100) and specificity of 100% (95% CI, 90 to 100) for the detection of Creutzfeldt–Jakob disease. By comparison, testing of cerebrospinal fluid samples from the same group of patients had a sensitivity of 77% (95% CI, 57 to 89) and a specificity of 100% (95% CI, 90 to 100). Nasal brushings elicited stronger and faster RT-QuIC responses than cerebrospinal fluid (PCreutzfeldt–Jakob disease and indicated substantial prion seeding activity lining the nasal vault. (Funded by the Intramural Research Program of the National Institute of Allergy and Infectious Diseases and others.) PMID:25099576

  12. Evaluation of a parent-designed programme to support tooth brushing of infants and young children*

    Science.gov (United States)

    Huebner, CE; Milgrom, P

    2015-01-01

    Objectives This study developed and tested an intervention to help parents establish a routine of brushing their young children’s teeth twice a day. Methods Community-based participatory research methods were used to engage parents in the design of the intervention to maximize its relevance and acceptability to others. Input was obtained by interviews and focus groups. The resulting intervention was four 90-min small-group sessions that provided educational information, direct instruction, practice and peer-to-peer problem-solving. A pre- to post-non-randomized design was used to evaluate the intervention’s effect to increase or maintain parents’ twice daily brushing. Results Intervention participants were 67 primary caregivers of children under six years of age. Of the 67 initial participants, 50 completed a post-intervention questionnaire administered 4 to 8 weeks following the intervention. The proportion of parents who reported brushing their young children’s teeth twice a day increased significantly from 59 per cent prior to the intervention to 89 per cent post-intervention (McNemar’s X2 = 10.71, P = 0.002). There were concomitant and statistically significant increases over the study period in parents’ confidence for brushing twice a day, attitudes about the importance of brushing and their self-efficacy for tooth brushing. Parents’ knowledge of children’s oral health, assessed by a 15-item scale developed for this study (‘Things to Know About Baby Teeth’), also increased significantly. Conclusions Twice daily tooth brushing is a low-cost, effective strategy to reduce the risk of childhood caries. As demonstrated here, community-based efforts can help parents achieve this important health behaviour. PMID:25070036

  13. Multilayer affinity adsorption of albumin on polymer brushes modified membranes in a continuous-flow system.

    Science.gov (United States)

    Hu, Meng-Xin; Li, Xiang; Li, Ji-Nian; Huang, Jing-Jing; Ren, Ge-Rui

    2018-02-23

    Polymer brushes modified surfaces have been widely used for protein immobilization and isolation. Modification of membranes with polymer brushes increases the surface concentration of affinity ligands used for protein binding. Albumin is one of the transporting proteins and shows a high affinity to bile acids. In this work, the modified membranes with cholic acid-containing polymer brushes can be facilely prepared by the immobilization of cholic acid on the poly(2-hydroxyethyl methacrylate) grafted microporous polypropylene membranes (MPPMs) for affinity adsorption of albumin. ATR/FT-IR and X-ray photoelectron spectroscopy were used to characterize the chemical composition of the modified membranes. Water contact angle measurements were used to analyze the hydrophilic/hydrophobic properties of the membrane surface. The modified MPPMs show a high affinity to albumin and have little non-specific adsorption of hemoglobin. The dynamic binding capacity of albumin in the continous-flow system increases with the cycle number and feed rate as the binding degree of cholic acid is moderate. The highest binding capacity of affinity membranes is about 52.49 g/m 2 membrane, which is about 24 times more than the monolayer binding capacity. These results reveal proteins could be captured in multilayers by the polymer brushes containing affinity ligands similar to the polymer brushes containing ion-exchange groups, which open up the potential of the polymer brushes containing affinity ligands in protein or another components separation. And the cholic acid containing polymer brushes modified membranes has the promising potential for albumin separation and purification rapidly from serum or fermented solution in medical diagnosis and bioseparation. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Evaluation of a parent-designed programme to support tooth brushing of infants and young children.

    Science.gov (United States)

    Huebner, C E; Milgrom, P

    2015-02-01

    This study developed and tested an intervention to help parents establish a routine of brushing their young children's teeth twice a day. Community-based participatory research methods were used to engage parents in the design of the intervention to maximize its relevance and acceptability to others. Input was obtained by interviews and focus groups. The resulting intervention was four 90-min small-group sessions that provided educational information, direct instruction, practice and peer-to-peer problem-solving. A pre- to post-non-randomized design was used to evaluate the intervention's effect to increase or maintain parents' twice daily brushing. Intervention participants were 67 primary caregivers of children under six years of age. Of the 67 initial participants, 50 completed a post-intervention questionnaire administered 4 to 8 weeks following the intervention. The proportion of parents who reported brushing their young children's teeth twice a day increased significantly from 59 per cent prior to the intervention to 89 per cent post-intervention (McNemar's X(2)  = 10.71, P = 0.002). There were concomitant and statistically significant increases over the study period in parents' confidence for brushing twice a day, attitudes about the importance of brushing and their self-efficacy for tooth brushing. Parents' knowledge of children's oral health, assessed by a 15-item scale developed for this study ('Things to Know About Baby Teeth'), also increased significantly. Twice daily tooth brushing is a low-cost, effective strategy to reduce the risk of childhood caries. As demonstrated here, community-based efforts can help parents achieve this important health behaviour. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Dual brush process for selective surface modification in graphoepitaxy directed self-assembly

    Science.gov (United States)

    Doise, Jan; Chan, Boon Teik; Hori, Masafumi; Gronheid, Roel

    2017-07-01

    Graphoepitaxy directed self-assembly is a potential low-cost solution for patterning via layers with pitches beyond the reach of a single optical lithographic exposure. In this process, selective control of the interfacial energy at the bottom and sidewall of the template is an important but challenging exercise. A dual brush process is implemented, in which two brushes with distinct end-groups are consecutively grafted to the prepattern to achieve fully independent modification of the bottom and sidewall surface of the template. A comprehensive study of hole pattern quality shows that using a dual brush process leads to a substantial improvement in terms of positional and dimensional variability across the process window. These findings will be useful to others who wish to manipulate polymer-surface interactions in directed self-assembly flows.

  16. The shear flow processing of controlled DNA tethering and stretching for organic molecular electronics.

    Science.gov (United States)

    Yu, Guihua; Kushwaha, Amit; Lee, Jungkyu K; Shaqfeh, Eric S G; Bao, Zhenan

    2011-01-25

    DNA has been recently explored as a powerful tool for developing molecular scaffolds for making reproducible and reliable metal contacts to single organic semiconducting molecules. A critical step in the process of exploiting DNA-organic molecule-DNA (DOD) array structures is the controlled tethering and stretching of DNA molecules. Here we report the development of reproducible surface chemistry for tethering DNA molecules at tunable density and demonstrate shear flow processing as a rationally controlled approach for stretching/aligning DNA molecules of various lengths. Through enzymatic cleavage of λ-phage DNA to yield a series of DNA chains of various lengths from 17.3 μm down to 4.2 μm, we have investigated the flow/extension behavior of these tethered DNA molecules under different flow strengths in the flow-gradient plane. We compared Brownian dynamic simulations for the flow dynamics of tethered λ-DNA in shear, and found our flow-gradient plane experimental results matched well with our bead-spring simulations. The shear flow processing demonstrated in our studies represents a controllable approach for tethering and stretching DNA molecules of various lengths. Together with further metallization of DNA chains within DOD structures, this bottom-up approach can potentially enable efficient and reliable fabrication of large-scale nanoelectronic devices based on single organic molecules, therefore opening opportunities in both fundamental understanding of charge transport at the single molecular level and many exciting applications for ever-shrinking molecular circuits.

  17. Calculating Payload for a Tethered Balloon System

    Science.gov (United States)

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  18. Hierarchical antifouling brushes for biosensing applications

    Czech Academy of Sciences Publication Activity Database

    de los Santos Pereira, Andres; Riedel, Tomáš; Brynda, Eduard; Rodriguez-Emmenegger, Cesar

    2014-01-01

    Roč. 202, 31 October (2014), s. 1313-1321 ISSN 0925-4005 R&D Projects: GA ČR GAP205/12/1702; GA MŠk(CZ) EE2.3.30.0029; GA MŠk(CZ) ED1.1.00/02.0109 Institutional support: RVO:61389013 Keywords : hierarchically structured brushes * affinity biosensors * fouling Subject RIV: CE - Biochemistry Impact factor: 4.097, year: 2014

  19. Gallium-containing polymer brush film as efficient supported Lewis acid catalyst in a glass microreactor

    Directory of Open Access Journals (Sweden)

    Rajesh Munirathinam

    2013-08-01

    Full Text Available Polystyrene sulfonate polymer brushes, grown on the interior of the microchannels in a microreactor, have been used for the anchoring of gallium as a Lewis acid catalyst. Initially, gallium-containing polymer brushes were grown on a flat silicon oxide surface and were characterized by FTIR, ellipsometry, and X-ray photoelectron spectroscopy (XPS. XPS revealed the presence of one gallium per 2–3 styrene sulfonate groups of the polymer brushes. The catalytic activity of the Lewis acid-functionalized brushes in a microreactor was demonstrated for the dehydration of oximes, using cinnamaldehyde oxime as a model substrate, and for the formation of oxazoles by ring closure of ortho-hydroxy oximes. The catalytic activity of the microreactor could be maintained by periodic reactivation by treatment with GaCl3.

  20. Towing Asteroids with Gravity Tractors Enhanced by Tethers and Solar Sails

    Science.gov (United States)

    Shen, Haijun; Roithmayr, Carlos M.

    2015-01-01

    Material collected from an asteroid's surface can be used to increase gravitational attraction between the asteroid and a Gravity Tractor (GT); the spacecraft therefore operates more effectively and is referred to as an Enhanced Gravity Tractor (EGT). The use of tethers and solar sails to further improve effectiveness and simplify operations is investigated. By employing a tether, the asteroidal material can be placed close to the asteroid while the spacecraft is stationed farther away, resulting in a better safety margin and improved thruster efficiency. A solar sail on a spacecraft can naturally provide radial offset and inter-spacecraft separation required for multiple EGTs.

  1. Stability control of a flexible maneuverable tethered space net robot

    Science.gov (United States)

    Zhang, Fan; Huang, Panfeng

    2018-04-01

    As a promising solution for active space debris capture and removal, a maneuverable Tethered Space Net Robot (TSNR) is proposed as an improved Space Tethered Net (TSN). In addition to the advantages inherit to the TSN, the TSNR's maneuverability expands the capture's potential. However, oscillations caused by the TSNR's flexibility and elasticity of make higher requests of the control scheme. Based on the dynamics model, a modified adaptive super-twisting sliding mode control scheme is proposed in this paper for TSNR stability control. The proposed continuous control force can effectively suppress oscillations. Theoretical verification and numerical simulations demonstrate that the desired trajectory can be tracked steadily and efficiently by employing the proposed control scheme.

  2. A smart core-sheath nanofiber that captures and releases red blood cells from the blood

    Science.gov (United States)

    Shi, Q.; Hou, J.; Zhao, C.; Xin, Z.; Jin, J.; Li, C.; Wong, S.-C.; Yin, J.

    2016-01-01

    A smart core-sheath nanofiber for non-adherent cell capture and release is demonstrated. The nanofibers are fabricated by single-spinneret electrospinning of poly(N-isopropylacrylamide) (PNIPAAm), polycaprolactone (PCL) and nattokinase (NK) solution blends. The self-assembly of PNIPAAm and PCL blends during the electrospinning generates the core-sheath PCL/PNIPAAm nanofibers with PNIPAAm as the sheath. The PNIPAAm-based core-sheath nanofibers are switchable between hydrophobicity and hydrophilicity with temperature change and enhance stability in the blood. When the nanofibers come in contact with blood, the NK is released from the nanofibers to resist platelet adhesion on the nanofiber surface, facilitating the direct capture and isolation of red blood cells (RBCs) from the blood above phase-transition temperature of PNIPAAm. Meanwhile, the captured RBCs are readily released from the nanofibers with temperature stimuli in an undamaged manner. The release efficiency of up to 100% is obtained while maintaining cellular integrity and function. This work presents promising nanofibers to effectively capture non-adherent cells and release for subsequent molecular analysis and diagnosis of single cells.A smart core-sheath nanofiber for non-adherent cell capture and release is demonstrated. The nanofibers are fabricated by single-spinneret electrospinning of poly(N-isopropylacrylamide) (PNIPAAm), polycaprolactone (PCL) and nattokinase (NK) solution blends. The self-assembly of PNIPAAm and PCL blends during the electrospinning generates the core-sheath PCL/PNIPAAm nanofibers with PNIPAAm as the sheath. The PNIPAAm-based core-sheath nanofibers are switchable between hydrophobicity and hydrophilicity with temperature change and enhance stability in the blood. When the nanofibers come in contact with blood, the NK is released from the nanofibers to resist platelet adhesion on the nanofiber surface, facilitating the direct capture and isolation of red blood cells (RBCs) from

  3. Synthesis of thermoresponsive poly(N-isopropylacrylamide) brush on silicon wafer surface via atom transfer radical polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Turan, Eylem; Demirci, Serkan [Department of Chemistry, Faculty of Art and Science, Gazi University, 06500 Besevler, Ankara (Turkey); Caykara, Tuncer, E-mail: caykara@gazi.edu.t [Department of Chemistry, Faculty of Art and Science, Gazi University, 06500 Besevler, Ankara (Turkey)

    2010-08-31

    Thermoresponsive poly(N-isopropylacrylamide) [poly(NIPAM)] brush on silicon wafer surface was prepared by combining the self-assembled monolayer of initiator and atom transfer radical polymerization (ATRP). The resulting polymer brush was characterized by in situ reflectance Fourier transform infrared spectroscopy, atomic force microscopy and ellipsometry techniques. Gel permeation chromatography determination of the number-average molecular weight and polydispersity index of the brush detached from the silicon wafer surface suggested that the surface-initiated ATRP method can provide relatively homogeneous polymer brush. Contact angle measurements exhibited a two-stage increase upon heating over the board temperature range 25-45 {sup o}C, which is in contrast to the fact that free poly(NIPAM) homopolymer in aqueous solution exhibits a phase transition at ca. 34 {sup o}C within a narrow temperature range. The first de-wetting transition takes place at 27 {sup o}C, which can be tentatively attributed to the n-cluster induced collapse of the inner region of poly(NIPAM) brush close to the silicon surface; the second de-wetting transition occurs at 38 {sup o}C, which can be attributed to the outer region of poly(NIPAM) brush, possessing much lower chain density compared to that of the inner part.

  4. The association between parents' perceived social norms for toothbrushing and the frequency with which they report brushing their child's teeth.

    Science.gov (United States)

    Trubey, R J; Moore, S C; Chestnutt, I G

    2015-06-01

    To determine whether parents' judgements on how often other parents brush their children's teeth are associated with the frequency with which they brush their own children's teeth, and their satisfaction with their child's brushing routine. A cross-sectional questionnaire survey completed by 297 parents of children aged 3-6. Parents were asked how often they brushed their own child's teeth per week, how often they thought other parents did so, and how satisfied they were with their child's toothbrushing routine. Demographic data were also collected. The mean frequency that parents brushed their children's teeth was 12.5 times per week. Multiple regression analysis tested the relationship between parents' perceptions of other parents brushing frequency (mean 10.5 times per week) and how often they brushed their own child's teeth, controlling for socio-demographic factors, and yielded a positive association (p parents' satisfaction with their child's brushing routine and the extent to which they thought it was better than that of the average child (p Parents' judgements on how frequently other parents brush their children's teeth are associated with their own behaviour and satisfaction. Re-framing oral health messages to include some form of social normative information ("most parents do this") may prove more persuasive than simple prescriptive advice ("you should do this").

  5. Thermodynamics, electrostatics, and ionic current in nanochannels grafted with pH-responsive end-charged polyelectrolyte brushes.

    Science.gov (United States)

    Chen, Guang; Das, Siddhartha

    2017-03-01

    In this paper, we study the thermodynamics, electrostatics, and an external electric field driven ionic current in a pH-responsive, end-charged polyelectrolyte (PE) brush grafted nanochannel. By employing a mean field theory, we unravel a highly nonintuitive interplay of pH and electrolyte salt concentration in dictating the height of the end-charged PE brush. Larger pH or weak hydrogen ion concentration leads to maximum ionization of the charge-producing group-as a consequence, the resulting the electric double layer (EDL) energy get maximized causing a maximum deviation of the brush height from the value (d 0 ) of the uncharged brush. This deviation may result in enhancement or lowering of the brush height as compared to d 0 depending on whether the PE end locates lower or higher than h/2 (h is the nanochannel half height) and the salt concentration. Subsequently, we use this combined PE-brush-configuration-EDL-electrostatics framework to compute the ionic current in the nanochannel. We witness that the ionic current for smaller pH is much larger despite the corresponding magnitude of the EDL electrostatic potential being much smaller-this stems from the presence of a much larger concentration of H+ ions at small pH and the fact that H+ ions have very large mobilities. In fact, this ionic current shows a steep variation with pH that can be useful in exploring new designs for applications involving quantification and characterization of ionic current in PE-brush-grafted nanochannels. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Tethered spinal cord: the effect of neurosurgery on the lower urinary tract and male sexual function

    NARCIS (Netherlands)

    Boemers, T. M.; van Gool, J. D.; de Jong, T. P.

    1995-01-01

    To determine the effect of neurosurgical untethering on the lower urinary tract and male sexual function, in patients with tethered spinal cord. Thirty-six children with tethered spinal cord due to neurospinal dysraphism were assessed clinically and urodynamically before and after surgical

  7. Thermo-responsive hydrogels for intravitreal injection and biomolecule release

    Science.gov (United States)

    Drapala, Pawel

    In this dissertation, we develop an injectable polymer system to enable localized and prolonged release of therapeutic biomolecules for improved treatment of Age-Related Macular Degeneration (AMD). Thermo-responsive hydrogels derived from N-isopropylacrylamide (NIPAAm) and cross-linked with poly(ethylene glycol) (PEG) poly(L-Lactic acid) (PLLA) copolymer were synthesized via free-radical polymerization. These materials were investigated for (a) phase change behavior, (b) in-vitro degradation, (c) capacity for controlled drug delivery, and (d) biocompatibility. The volume-phase transition temperature (VPTT) of the PNIPAAm- co-PEG-b-PLLA hydrogels was adjusted using hydrophilic and hydrophobic moieties so that it is ca. 33°C. These hydrogels did not initially show evidence of degradation at 37°C due to physical cross-links of collapsed PNIPAAm. Only after addition of glutathione chain transfer agents (CTA)s to the precursor did the collapsed hydrogels become fully soluble at 37°C. CTAs significantly affected the release kinetics of biomolecules; addition of 1.0 mg/mL glutathione to 3 mM cross-linker accelerated hydrogel degradation, resulting in 100% release in less than 2 days. This work also explored the effect of PEGylation in order to tether biomolecules to the polymer matrix. It was demonstrated that non-site-specific PEGylation can postpone the burst release of solutes (up to 10 days in hydrogels with 0.5 mg/mL glutathione). Cell viability assays showed that at least two 20-minute buffer extraction steps were needed to remove cytotoxic elements from the hydrogels. Clinically-used therapeutic biomolecules LucentisRTM and AvastinRTM were demonstrated to be both stable and bioactive after release form PNIPAAm-co-PEG-b-PLLA hydrogels. The thermo-responsive hydrogels presented here offer a promising platform for the localized delivery of proteins such as recombinant antibodies.

  8. Plaque-left-behind after brushing: intra-oral reservoir for antibacterial toothpaste ingredients

    OpenAIRE

    Otten, Marieke P. T.; Busscher, Henk J.; Abbas, Frank; van der Mei, Henny C.; van Hoogmoed, Chris G.

    2012-01-01

    Objectives Plaque is never fully removed by brushing and may act as a reservoir for antibacterial ingredients, contributing to their substantive action. This study investigates the contribution of plaque-left-behind and saliva towards substantivity of three antibacterial toothpastes versus a control paste without antibacterial claims. Materials and methods First, volunteers brushed 2 weeks with a control or antibacterial toothpaste. Next, plaque and saliva samples were collected 6 and 12 h af...

  9. Well-defined polyethylene molecular brushes by polyhomologation and ring opening metathesis polymerization

    KAUST Repository

    Zhang, Hefeng; Gnanou, Yves; Hadjichristidis, Nikolaos

    2014-01-01

    A novel strategy using polyhomologation and ring opening metathesis polymerization (ROMP) has been developed for the synthesis of well-defined polyethylene (PE) molecular brushes. Polyhomologation was used to afford an OH-terminated PE, which after transformation to the norbornyl PE macromonomer was subjected to ROMP. Kinetics of ROMP of the PE macromonomer was studied by in situ1H NMR monitoring. The brush structure was proved from HT-GPC, 1H NMR and DSC results.

  10. Operator's Manual for SHEBA Powered Tether Balloon System

    Science.gov (United States)

    Lappen, Cara-Lyn; Randall, David A.

    1998-01-01

    The Surface Heat and Energy Budget of the Arctic (SHEBA) was an intensive field project which took place in the Arctic Ocean from October 1997 through October 1998. Its purpose was to measure as many facets of the Arctic environment as possible so that we would be able to better understand the interaction between the ice, atmosphere, and ocean and their interactions with global climate. One aspect of the atmospheric field component was launching tethered balloons to monitor the profiles of temperature, wind, pressure, and humidity, as well as examine the vertical structure of cloud droplet sizes and distributions. The tethered balloon that we used was one specially designed for use in freezing climates by SPEC Corporation in Boulder, Colorado. A special winch that was able to withstand Arctic temperature and weather became necessary when the testing of simple winch systems used in warmer climates failed under these extreme conditions. The purpose of this manual is to acquaint any new user to the powered tethered balloon system deployed at the The Surface Heat and Energy Budget of the Arctic (SHEBA ice camp. It includes a description of the preparations necessary to get ready for a launch, the mechanics of the actual launch, and an account of the proper procedure for taking down the equipment when finished. It will also include tips on how to minimize potential equipment failures, some trouble shooting, and some safety ideas. This manual is designed so that new operators can use the system with minimal previous training. At the end of this manual, the reader will find a quick checklist.

  11. Electromechanical engineering in SnO2 nanoparticle tethered hybrid ionic liquid

    Science.gov (United States)

    Deb, Debalina; Bhattacharya, Subhratanu

    2017-05-01

    Challenge of developing electrolytes comprising synergic properties of high mechanical strength with superior electrical and electrochemical properties has so far been unmet towards the application of secondary storage devices. In this research, we have engineered the electromechanical properties of 2-(trimethylamino) ethyl methacrylate bis(trifluoromethylsulfonyl) imide [TMEM]TFSI ionic liquid by tethering silane modified SnO2 nanoparticles within it. Different percentages of tethering are employed to achieve improved ionic conductivity, better discharge/ charging ratio (40%) along with gel like mechanical properties. Our findings appear to provide an optimal solution towards the future prospects in application in a number of areas, notably in energy-related technologies.

  12. Polyethyleneimine brushes effectively inhibit encrustation on polyurethane ureteral stents both in dynamic bioreactor and in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Gultekinoglu, Merve [Department of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Hacettepe University, Ankara 06100 (Turkey); Bioengineering Division, Institute for Graduate Studies in Science and Engineering, Hacettepe University, Ankara 06532 (Turkey); Kurum, Barış [Department of Surgery, Faculty of Veterinary Medicine, Kırıkkale University, Kırıkkale 71450 (Turkey); Karahan, Siyami [Department of Histology and Embryology, Faculty of Veterinary Medicine, Kırıkkale University, Kırıkkale 71450 (Turkey); Kart, Didem; Sagiroglu, Meral [Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Hacettepe University, Ankara 06100 (Turkey); Ertaş, Nusret [Department of Analytical Chemistry, Faculty of Pharmacy, Gazi University, Ankara 06330 (Turkey); Haluk Ozen, A. [Department of Urology, Faculty of Medicine, Hacettepe University, Ankara 06100 (Turkey); Ulubayram, Kezban, E-mail: ukezban@hacettepe.edu.tr [Department of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Hacettepe University, Ankara 06100 (Turkey); Bioengineering Division, Institute for Graduate Studies in Science and Engineering, Hacettepe University, Ankara 06532 (Turkey)

    2017-02-01

    Polyurethane (PU) ureteral stents have been widely used as biomedical devices to aid the flow of the urine. Due to the biofilm formation and encrustation complications it has been hindered their long term clinical usage. To overcome these complications, in this study, cationic polyethyleneimine (PEI) brushes grafted on PU stents and their performances were tested both in a dynamic biofilm reactor system (in vitro) and in a rat model (in vivo). Thus, we hypothesized that PEI brushes inhibit bacterial adhesion owing to the dynamic motion of brushes in liquid environment. In addition, cationic structure of PEI disrupts the membrane and so kills the bacteria on time of contact. Cationic PEI brushes decreased the biofilm formation up to 2 orders of magnitude and approximately 50% of encrustation amount in respect to unmodified PU, in vitro. In addition, according to Atomic Absorption Spectroscopy (AAS) results, approximately 90% of encrustation was inhibited on in vivo animal models. Decrease in encrustation was clearly observed on the stents obtained from rat model, by Scanning Electron Microscopy (SEM). Also, histological evaluations showed that; PEI brush grafting decreased host tissue inflammation in close relation to decrease in biofilm formation and encrustation. As a results; dual effect of anti-adhesive and contact-killing antibacterial strategy showed high efficiency on PEI brushes grafted PU stents both in vitro and in vivo.

  13. Polyethyleneimine brushes effectively inhibit encrustation on polyurethane ureteral stents both in dynamic bioreactor and in vivo

    International Nuclear Information System (INIS)

    Gultekinoglu, Merve; Kurum, Barış; Karahan, Siyami; Kart, Didem; Sagiroglu, Meral; Ertaş, Nusret; Haluk Ozen, A.; Ulubayram, Kezban

    2017-01-01

    Polyurethane (PU) ureteral stents have been widely used as biomedical devices to aid the flow of the urine. Due to the biofilm formation and encrustation complications it has been hindered their long term clinical usage. To overcome these complications, in this study, cationic polyethyleneimine (PEI) brushes grafted on PU stents and their performances were tested both in a dynamic biofilm reactor system (in vitro) and in a rat model (in vivo). Thus, we hypothesized that PEI brushes inhibit bacterial adhesion owing to the dynamic motion of brushes in liquid environment. In addition, cationic structure of PEI disrupts the membrane and so kills the bacteria on time of contact. Cationic PEI brushes decreased the biofilm formation up to 2 orders of magnitude and approximately 50% of encrustation amount in respect to unmodified PU, in vitro. In addition, according to Atomic Absorption Spectroscopy (AAS) results, approximately 90% of encrustation was inhibited on in vivo animal models. Decrease in encrustation was clearly observed on the stents obtained from rat model, by Scanning Electron Microscopy (SEM). Also, histological evaluations showed that; PEI brush grafting decreased host tissue inflammation in close relation to decrease in biofilm formation and encrustation. As a results; dual effect of anti-adhesive and contact-killing antibacterial strategy showed high efficiency on PEI brushes grafted PU stents both in vitro and in vivo.

  14. Surface roughness and hardness of yttria stabilized zirconia (Y-TZP after 10 years of simulated brushing

    Directory of Open Access Journals (Sweden)

    Lucas Miguel Candido

    Full Text Available Introduction: The Y-TZP zirconia used for prosthetic infrastructure, in some clinical situations, can be exposed to the oral environment. In these situations, a polished surface without changes is extremely important. Objective: The aim of this study was to evaluate the mean roughness (Ra and Vickers hardness of Y-TZP zirconia (Lava™ after simulating ten years of brushing. Material and method: Thirty-six Y-TZP bar-shaped specimens (20mm X 4mm X 1.2mm were divided into three groups: storage in distilled water (DW, n=12, control; brushing with distilled water (BDW, n=12 and brushing with distilled water and fluoride toothpaste (BFT, n=12. Brushing was performed using a brushing machine with a soft-bristled toothbrush, simulating 10 years of brushing (878.400 cycles, 100gf. The mean roughness (Ra in μm and Vickers hardness (VHN of all specimens were measured twice: before and after the experimental treatment, in profilometer and microhardness tester (500gf, 30 seconds, respectively. Data were analyzed using the two-way ANOVA test (α = 0.05. Result: The interaction between groups was not significant for roughness (p = 0.701 nor for hardness (p = 0.928. The final averages for Ra (μm were equal to: DW - 0.63; BDW - 0.64; and, BFT - 0.68. The final averages for Vickers hardness (VHN were: DW - 1301.16; BDW - 1316.60; and, BFT - 1299.58. Conclusion: It was concluded that the brushing with distilled or fluoridated toothpaste was not able to change the roughness and hardness of Y-TZP zirconia used in this study.

  15. Post-translational suppression of expression of intestinal brush border enzymes by fructose

    DEFF Research Database (Denmark)

    Danielsen, E M

    1989-01-01

    The two major dietary sugars, fructose and sucrose, were found to suppress effectively the biosynthetic renewal of brush border enzymes in the gut. When studied in cultured explants of pig small intestine mucosa, 10-50 mM concentrations of fructose completely prevented the expression of mature...... cotranslational glycosylation that in turn triggers a rapid proteolytic breakdown. Our findings suggest that renewal of digestive brush border enzymes is transiently suppressed during intake of fructose- or sucrose-rich meals....

  16. Brushed Target on Rock 'Champagne' in Gusev Crater

    Science.gov (United States)

    2005-01-01

    NASA's Mars Exploration Rover Spirit took this microscopic image of a target called 'Bubbles' on a rock called 'Champagne' after using its rock abrasion tool to brush away a coating of dust. The circular brushed area is about 5 centimeters (2 inches) across. This rock is different from rocks out on the plains of Gusev Crater but is similar to other rocks in this area of the 'Columbia Hills' in that it has higher levels of phosphorus. Plagioclase, a mineral commonly found in igneous rocks, is also present in these rocks, according to analysis with the minature thermal emission spectrometer. By using the alpha particle X-ray spectrometer to collect data over multiple martian days, or sols, scientists are also beginning to get measurements of trace elements in these rocks. Spirit took the images that are combined into this mosaic on sol 354 (Dec. 30, 2004).

  17. Insight into the electrical properties and chain conformation of spherical polyelectrolyte brushes by dielectric spectroscopy

    Science.gov (United States)

    Guo, Xiaoxia; Zhao, Kongshuang

    2017-02-01

    We report here a dielectric study on three kinds of anionic spherical polyelectrolyte brush (SPBs, consisting of a polystyrene (PS) core and three different poly (acrylic acid) chains grafted onto the core) suspensions over a frequency ranging from 40 Hz to 110 MHz. The relaxation behavior of the SPB suspensions shows significant changes in the brush-layer properties when the mass fraction of SPBs and the pH of the suspensions change. Two definite relaxations related to the interfacial polarization are observed around 100 kHz and 10 MHz. A single-layer spherical-shell model is applied to describe the SPB suspensions wherein the suspended SPB is modeled as a spherical-shell composite particle in which an insulated PS sphere is surrounded by a conducting ion-permeable shell (the polyelectrolyte chain layer). We developed the curve-fitting procedure to analyze the dielectric spectrum in order to obtain the dielectric properties of the components of the SPBs, especially the properties of the polyelectrolyte brush. Based on this method and model, the permittivity and conductivity of the brush layer, ζ potential, etc are calculated. The ordered orientation of the water molecules in the layer leads to an additional electrical dipole moment; increasing pH causes the brush layer to swell. In addition, the repulsive force between the SPB particles are evaluated using the brush-layer thickness, which is obtained by fitting dielectric spectra, combined with relative theoretical formulas. Increasing PH values or SPB concentration would improve the stability of the SPBs dispersion.

  18. Dynamic Properties of Star-Branched Polymer Brushes

    International Nuclear Information System (INIS)

    Sikorski, A.; Romiszowski, P.

    2004-01-01

    We studied a simplified model of a polymer brush. It consisted of star-branched chains, which were restricted to a simple cubic lattice. Each star-branched macromolecule consisted of three linear arms of equal length emanating from a common origin (the branching point). The chains were grafted to an impenetrable surface, i.e. they were terminally attached to the surface with one arm. The number of chains was varied from low to high grafting density. The model system was studied at good solvent conditions because the excluded volume effect was the only potential of interaction included in the model. The properties of this model system were studied by means of Monte Carlo simulation. The sampling algorithm was based on local changes of chain conformations. The dynamic properties of the polymer brush were studied and correlated with its structure. The differences in relaxation times of particular star arms were shown. The short-time mobility of polymer layers was analyzed. The lateral self-diffusion of chains was also studied and discussed. (author)

  19. Stationary Tether Device for Buoy Apparatus and System for Using

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A rigid, neutrally buoyant hydrodynamicaly-faired tether and associated fastening hardware that loosely holds a bathymetric float at a predetermined distance from a...

  20. Fiber Optic Shape Sensing for Tethered Marsupial Rovers, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Building upon the successful proof of concept work in Phase I, Luna Innovations Incorporated is proposing to design, build, and test a sensing tether for marsupial...

  1. The effect of brushing with nano calcium carbonate and calcium carbonate toothpaste on the surface roughness of nano-ionomer

    Science.gov (United States)

    Anisja, D. H.; Indrani, D. J.; Herda, E.

    2017-08-01

    Nanotechnology developments in dentistry have resulted in the development of nano-ionomer, a new restorative material. The surface roughness of restorative materials can increase bacteria adhesion and lead to poor oral hygiene. Abrasive agents in toothpaste can alter tooth and restorative material surfaces. The aim of this study is to identify the effect of brushing with nano calcium carbonate, and calcium carbonate toothpaste on surface roughness of nano-ionomer. Eighteen nano-ionomer specimens were brushed with Aquabidest (doubledistilled water), nano calcium carbonate and calcium carbonate toothpaste. Brushing lasted 30 minutes, and the roughness value (Ra) was measured after each 10 minute segment using a surface roughness tester. The data was analyzed using repeated ANOVA and one-way ANOVA test. The value of nano-ionomer surface roughness increased significantly (p<0.05) after 20 minutes of brushing with the nano calcium carbonate toothpaste. Brushing with calcium carbonate toothpaste leaves nano-ionomer surfaces more rugged than brushing with nano calcium carbonate toothpaste.

  2. Chain-brush method in delimbing and debarking of wood; Ketjuharja-menetelmae puun karsinnassa ja kuorinnassa

    Energy Technology Data Exchange (ETDEWEB)

    Aho, V J; Nikala, L; Laitinen, H [VTT Energy, Jyvaeskylae (Finland)

    1997-12-01

    The objective of this project is to study, develop and make an integrated method for production of wood fuels and industrial raw material, promoting the competitiveness of the refining and energy usage of felling residues based on chain-brush delimbing-debarking technology, operational. VTT Energy has tested different brush constructions and the thickness of chains using varying feeding speeds and rotation speeds of the brush-delimber. First thinning pine, spruce and birch have been tested as single trees. Different temperatures have been used in the summer, and frozen timber in the winter. A method has been developed for estimation of the bark content and the wood losses for pine. The method is based on the measurement of the areas covered by bark and the debarked areas of the timber, on the bark thickness values and dry substance content of the wood obtained from the literature, as well as on the calculation formulas obtained from these. Unscrambler software will be used to assist the planning of the tests, and for analysing of the results. The utilisation of the chain-brush method for different wood-species, and the effect of different chain adjustments will be simulated by the software. The chain-brush delimbing will be studied using the high-speed camera acquired to VTT Energy. (orig.)

  3. 75 FR 47316 - Centennial Challenges 2010 Strong Tether Challenge

    Science.gov (United States)

    2010-08-05

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION Centennial Challenges 2010 Strong Tether Challenge... teams that wish to compete may register. Centennial Challenges is a program of prize competitions to..., please visit: http://www.spaceward.org/elevator2010-ts . For general information on the NASA Centennial...

  4. Involvement of detergent-insoluble complexes in the intracellular transport of intestinal brush border enzymes

    DEFF Research Database (Denmark)

    Danielsen, E M

    1995-01-01

    A number of transmembrane digestive enzymes of the porcine small intestinal brush border membrane were found to be partially Triton X-100-insoluble at 0 degree C and colocalized in gradient centrifugation experiments with the GPI-anchored alkaline phosphatase in low-density, detergent-insoluble c...... intracellularly. I therefore propose that, in the enterocyte, the brush border enzymes are targeted directly from the trans-Golgi network toward the apical cell surface......., and their insolubility increased to that of the steady-state level soon after they achieved their mature, complex glycosylation, i.e., after passage through the Golgi complex. Detergent-insoluble complexes isolated by density gradient centrifugation were highly enriched in brush border enzymes, and the enrichment...

  5. Oral Health: Brush Up on Dental Care Basics

    Science.gov (United States)

    ... Mayo Clinic Staff Your smile depends on simple dental care habits, such as brushing and flossing. But are you using the right techniques? Follow these steps to protect your oral health. Oral health begins with clean teeth. Keeping the area where your teeth meet your ...

  6. Immunoelectrophoretic studies on pig intestinal brush border proteins

    DEFF Research Database (Denmark)

    Danielsen, Erik Michael; Sjöström, H; Norén, O

    1977-01-01

    Brush borders were prepared from pig intestinal mucosa and the membrane proteins solubilized with either Triton X-100 or papain. Proteins, thus released, were used as antigens to raise antisera in rabbits. The immunoglobulin G fractions were isolated and shown by the double layer immunofluorescence...

  7. Clustering of tethered satellite system simulation data by an adaptive neuro-fuzzy algorithm

    Science.gov (United States)

    Mitra, Sunanda; Pemmaraju, Surya

    1992-01-01

    Recent developments in neuro-fuzzy systems indicate that the concepts of adaptive pattern recognition, when used to identify appropriate control actions corresponding to clusters of patterns representing system states in dynamic nonlinear control systems, may result in innovative designs. A modular, unsupervised neural network architecture, in which fuzzy learning rules have been embedded is used for on-line identification of similar states. The architecture and control rules involved in Adaptive Fuzzy Leader Clustering (AFLC) allow this system to be incorporated in control systems for identification of system states corresponding to specific control actions. We have used this algorithm to cluster the simulation data of Tethered Satellite System (TSS) to estimate the range of delta voltages necessary to maintain the desired length rate of the tether. The AFLC algorithm is capable of on-line estimation of the appropriate control voltages from the corresponding length error and length rate error without a priori knowledge of their membership functions and familarity with the behavior of the Tethered Satellite System.

  8. Tethered balloon operation for wintering aerosol measurements in the lower troposphere at Syowa Station, Antarctica

    OpenAIRE

    Keiichiro Hara; Kazuo Osada; Takashi Yamanouchi

    2007-01-01

    The 46th Japanese Antarctic Research Expedition (JARE-46) carried out twenty seven tethered-balloon-borne aerosol measurements at Syowa Station for better understanding of aerosol chemical and physical properties in the lower troposphere from 6th January 2005 until 11 December 2005. This report summarizes the plan, preparation, field activities and some troubles/problems in the tethered-balloon observations.

  9. Tethered balloon operation for wintering aerosol measurements in the lower troposphere at Syowa Station, Antarctica

    Directory of Open Access Journals (Sweden)

    Keiichiro Hara

    2007-03-01

    Full Text Available The 46th Japanese Antarctic Research Expedition (JARE-46 carried out twenty seven tethered-balloon-borne aerosol measurements at Syowa Station for better understanding of aerosol chemical and physical properties in the lower troposphere from 6th January 2005 until 11 December 2005. This report summarizes the plan, preparation, field activities and some troubles/problems in the tethered-balloon observations.

  10. Lifting options for stratospheric aerosol geoengineering: advantages of tethered balloon systems.

    Science.gov (United States)

    Davidson, Peter; Burgoyne, Chris; Hunt, Hugh; Causier, Matt

    2012-09-13

    The Royal Society report 'Geoengineering the Climate' identified solar radiation management using albedo-enhancing aerosols injected into the stratosphere as the most affordable and effective option for geoengineering, but did not consider in any detail the options for delivery. This paper provides outline engineering analyses of the options, both for batch-delivery processes, following up on previous work for artillery shells, missiles, aircraft and free-flying balloons, as well as a more lengthy analysis of continuous-delivery systems that require a pipe connected to the ground and supported at a height of 20 km, either by a tower or by a tethered balloon. Towers are shown not to be practical, but a tethered balloon delivery system, with high-pressure pumping, appears to have much lower operating and capital costs than all other delivery options. Instead of transporting sulphuric acid mist precursors, such a system could also be used to transport slurries of high refractive index particles such as coated titanium dioxide. The use of such particles would allow useful experiments on opacity, coagulation and atmospheric chemistry at modest rates so as not to perturb regional or global climatic conditions, thus reducing scale-up risks. Criteria for particle choice are discussed, including the need to minimize or prevent ozone destruction. The paper estimates the time scales and relatively modest costs required if a tethered balloon system were to be introduced in a measured way with testing and development work proceeding over three decades, rather than in an emergency. The manufacture of a tether capable of sustaining the high tensions and internal pressures needed, as well as strong winds, is a significant challenge, as is the development of the necessary pumping and dispersion technologies. The greatest challenge may be the manufacture and launch of very large balloons, but means have been identified to significantly reduce the size of such balloons or aerostats.

  11. Monitoring the Switching of Single BSA-ATTO 488 Molecules Covalently End-Attached to a pH-Responsive PAA Brush

    NARCIS (Netherlands)

    Akkilic, Namik; Molenaar, Robert; Claessens, Mireille Maria Anna Elisabeth; Blum, Christian; de Vos, Wiebe Matthijs

    2016-01-01

    We describe a novel combination of a responsive polymer brush and a fluorescently labeled biomolecule, where the position of the biomolecule can be switched from inside to outside the brush and vice versa by a change in pH. For this, we grafted ultrathin, amino-terminated poly(acrylic acid) brushes

  12. Stabilization of periodic solutions in a tethered satellite system by damping injection

    DEFF Research Database (Denmark)

    Larsen, Martin Birkelund; Blanke, Mogens

    2009-01-01

    presents a control design for stabilizing these periodic solutions. The design consists of a control law for stabilizing the open-loop equilibrium and a bias term which forces the system trajectory away from the equilibrium. The tether needs to be positioned away from open-loop equilibrium for the tether...... to affect the orbit parameters. An approximation of the periodic solutions of the closed loop system is found as a series expansion in the parameter plane spanned by the controller gain and the bias term. The stability of the solutions is investigated using linear Floquet analysis of the variational...

  13. Crowded, Confined, and Frustrated: Dynamics of Molecules Tethered to Nanoparticles

    KAUST Repository

    Agarwal, Praveen; Kim, Sung A.; Archer, Lynden A.

    2012-01-01

    Above a critical chemistry-dependent molecular weight, all polymer molecules entangle and, as a result, exhibit slow dynamics, enhanced viscosity, and elasticity. Herein we report on the dynamics of low molecular weight polymers tethered

  14. Disaster Coverage Predication for the Emerging Tethered Balloon Technology: Capability for Preparedness, Detection, Mitigation, and Response.

    Science.gov (United States)

    Alsamhi, Saeed H; Samar Ansari, Mohd; Rajput, Navin S

    2018-04-01

    A disaster is a consequence of natural hazards and terrorist acts, which have significant potential to disrupt the entire wireless communication infrastructure. Therefore, the essential rescue squads and recovery operations during a catastrophic event will be severely debilitated. To provide efficient communication services, and to reduce casualty mortality and morbidity during the catastrophic events, we proposed the Tethered Balloon technology for disaster preparedness, detection, mitigation, and recovery assessment. The proposed Tethered Balloon is applicable to any type of disaster except for storms. The Tethered Balloon is being actively researched and developed as a simple solution to improve the performance of rescues, facilities, and services of emergency medical communication in the disaster area. The most important requirement for rescue and relief teams during or after the disaster is a high quality of service of delivery communication services to save people's lives. Using our proposed technology, we report that the Tethered Balloon has a large disaster coverage area. Therefore, the rescue and research teams are given higher priority, and their performance significantly improved in the particular coverage area. Tethered Balloon features made it suitable for disaster preparedness, mitigation, and recovery. The performance of rescue and relief teams was effective and efficient before and after the disaster as well as can be continued to coordinate the relief teams until disaster recovery. (Disaster Med Public Health Preparedness. 2018;12:222-231).

  15. Refining the tethering of American oysters (Crassostrea virginica) to measure the effects of two environmental stressors.

    Science.gov (United States)

    Poirier, Luke A; Gilbert, Shane T C; St-Hilaire, Sophie; Davidson, Jeff; Cox, Ruth; Quijón, Pedro A

    2018-02-01

    Tethering assays, or the physical restraint of test organisms, has been used in the past to measure selected organisms' response to stressors while removing the observer from the experimental setting. Although informative for monitoring and hypothesis testing, these assays often used microfilaments that have been found to be too invasive or prone to biases given their effects on test organisms' behavior. Here, we describe a new variation of tethering using American oysters (Crassostrea virginica) and illustrate its use in the study of their mortality rates as a result of two stressors: siltation and predation by a non-indigenous species. Our protocol identified a resistant (non-toxic) glue that could be used to attach oysters to stone slabs, thus partially mimicking the natural cementation of the shell to natural substrates. This variation of tethering was harmless and maintained oysters' body position and natural ability to filter feed. Using tethered oysters in separate two-week field cage experiments, we also show how siltation and predation by a non-indigenous species (the European green crab, Carcinus maenas), caused a gradual, easily measurable increase in oyster mortality rates. We argue that this variation of tethering is a cost-effective and advantageous way to monitor or test the effects of these and other stressors on oysters and similar species. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Isothermal pumping analysis for high-altitude tethered balloons.

    Science.gov (United States)

    Kuo, Kirsty A; Hunt, Hugh E M

    2015-06-01

    High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal analysis is used to determine the variation of pressures and velocities along the pipe length. Results show that transport of small quantities of hydrogen to power fuel cells and maintain balloon buoyancy can be achieved at pressures and temperatures that are tolerable in terms of both the pipe strength and the current state of pumping technologies. To avoid solidification, transport of SO2 would require elevated temperatures that cannot be tolerated by the strength fibres in the pipe. While the use of particle-based slurries rather than SO2 for climate engineering can reduce the pipe size significantly, the pumping pressures are close to the maximum bursting pressure of the pipe.

  17. "Long life" DC brush motor for use on the Mars surveyor program

    Science.gov (United States)

    Braun, David; Noon, Don

    1998-01-01

    DC brush motors have several qualities which make them very attractive for space flight applications. Their mechanical commutation is simple and lightweight, requiring no external sensing and control in order to function properly. They are extremely efficient in converting electrical energy into mechanical energy. Efficiencies over 80% are not uncommon, resulting in high power throughput to weight ratios. However, the inherent unreliability and short life of sliding electrical contacts, especially in vacuum, have driven previous programs to utilize complex brushless DC or the less efficient stepper motors. The Mars Surveyor Program (MSP'98) and the Shuttle Radar Topography Mission (SRTM) have developed a reliable "long life" brush type DC motor for operation in low temperature, low pressure CO2 and N2, utilizing silver-graphite brushes. The original intent was to utilize this same motor for SRTM's space operation, but the results thus far have been unsatisfactory in vacuum. This paper describes the design, test, and results of this development.

  18. Hydrogel brushes grafted from stainless steel via surface-initiated atom transfer radical polymerization for marine antifouling

    Science.gov (United States)

    Wang, Jingjing; Wei, Jun

    2016-09-01

    Crosslinked hydrogel brushes were grafted from stainless steel (SS) surfaces for marine antifouling. The brushes were prepared by surface-initiated atom transfer radical polymerization (SI-ATRP) of 2-methacryloyloxyethyl phosphorylcholine (MPC) and poly(ethylene glycol) methyl ether methacrylate (PEGMA) respectively with different fractions of crosslinker in the feed. The grafted layers prepared with different thickness were characterized by X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), ellipsometry and water contact angle measurements. With the increase in the fraction of crosslinker in the feed, the thickness of the grafted layer increased and the surface became smooth. All the brush-coated SS surfaces could effectively reduce the adhesion of bacteria and microalgae and settlement of barnacle cyprids, as compared to the pristine SS surface. The antifouling efficacy of the PEGMA polymer (PPEGMA)-grafted surface was higher than that of the MPC polymer (PMPC)-grafted surfaces. Furthermore, the crosslinked hydrogel brush-grafted surfaces exhibited better fouling resistance than the non-crosslinked polymer brush-grafted surfaces, and the antifouling efficacy increased with the crosslinking density. These hydrogel coatings of low toxicity and excellent anti-adhesive characteristics suggested their useful applications as environmentally friendly antifouling coatings.

  19. Brushes and picks used on nails during the surgical scrub to reduce bacteria: a randomised trial.

    Science.gov (United States)

    Tanner, J; Khan, D; Walsh, S; Chernova, J; Lamont, S; Laurent, T

    2009-03-01

    Though brushes are no longer used on the hands and forearms during the surgical scrub, they are still widely used on the nails. The aim of this study was to determine whether nail picks and nail brushes are effective in providing additional decontamination during a surgical hand scrub. A total of 164 operating department staff were randomised to undertake one of the following three surgical hand-scrub protocols: chlorhexidine only; chlorhexidine and a nail pick; or chlorhexidine and a nail brush. Bacterial hand sampling was conducted before and 1h after scrubbing using a modified version of the glove juice method. No statistically significant differences in bacterial numbers were found between any two of the three intervention groups. Nail brushes and nail picks used during surgical hand scrubs do not decrease bacterial numbers and are unnecessary.

  20. Associative visual learning by tethered bees in a controlled visual environment.

    Science.gov (United States)

    Buatois, Alexis; Pichot, Cécile; Schultheiss, Patrick; Sandoz, Jean-Christophe; Lazzari, Claudio R; Chittka, Lars; Avarguès-Weber, Aurore; Giurfa, Martin

    2017-10-10

    Free-flying honeybees exhibit remarkable cognitive capacities but the neural underpinnings of these capacities cannot be studied in flying insects. Conversely, immobilized bees are accessible to neurobiological investigation but display poor visual learning. To overcome this limitation, we aimed at establishing a controlled visual environment in which tethered bees walking on a spherical treadmill learn to discriminate visual stimuli video projected in front of them. Freely flying bees trained to walk into a miniature Y-maze displaying these stimuli in a dark environment learned the visual discrimination efficiently when one of them (CS+) was paired with sucrose and the other with quinine solution (CS-). Adapting this discrimination to the treadmill paradigm with a tethered, walking bee was successful as bees exhibited robust discrimination and preferred the CS+ to the CS- after training. As learning was better in the maze, movement freedom, active vision and behavioral context might be important for visual learning. The nature of the punishment associated with the CS- also affects learning as quinine and distilled water enhanced the proportion of learners. Thus, visual learning is amenable to a controlled environment in which tethered bees learn visual stimuli, a result that is important for future neurobiological studies in virtual reality.

  1. A Fiber-Optic Tether for the Hull Search UUV System Documentation

    National Research Council Canada - National Science Library

    Buescher, J. G

    2006-01-01

    ...) conducting ship hull inspection missions, defines the required specifications that will allow the integration and installation of a FO tether system on UUVs with ship hull inspection capability...

  2. Clickable antifouling polymer brushes for polymer pen lithography

    Czech Academy of Sciences Publication Activity Database

    Bog, U.; de los Santos Pereira, Andres; Mueller, S. L.; Havenridge, S.; Parrillo, Viviana; Bruns, M.; Holmes, A. E.; Rodriguez-Emmenegger, C.; Fuchs, H.; Hirtz, M.

    2017-01-01

    Roč. 9, č. 13 (2017), s. 12109-12117 ISSN 1944-8244 R&D Projects: GA ČR(CZ) GJ15-09368Y Institutional support: RVO:61389013 Keywords : antifouling * biofunctional interfaces * polymer brushes Subject RIV: CD - Macromolecular Chemistry OBOR OECD: Polymer science Impact factor: 7.504, year: 2016

  3. A simplified tether model for molecular motor transporting cargo

    International Nuclear Information System (INIS)

    Fang-Zhen, Li; Li-Chun, Jiang

    2010-01-01

    Molecular motors are proteins or protein complexes which function as transporting engines in biological cells. This paper models the tether between motor and its cargo as a symmetric linear potential. Different from Elston and Peskin's work for which performance of the system was discussed only in some limiting cases, this study produces analytic solutions of the problem for general cases by simplifying the transport system into two physical states, which makes it possible to discuss the dynamics of the motor–cargo system in detail. It turns out that the tether strength between motor and cargo should be greater than a threshold or the motor will fail to transport the cargo, which was not discussed by former researchers yet. Value of the threshold depends on the diffusion coefficients of cargo and motor and also on the strength of the Brownian ratchets dragging the system. The threshold approaches a finite constant when the strength of the ratchet tends to infinity. (general)

  4. Phase 3 study of selected tether applications in space. Volume 2: Study results

    Science.gov (United States)

    1986-01-01

    Engineering designs were developed relative to a tethered launch assist from the Shuttle for payloads up to 10,000 kg mass and the tethering of a 15,000 kg science platform from the space station. These designs are used for a cost benefit analysis which assesses the feasibility of using such systems as a practical alternative to what would otherwise be accomplished by conventional means. The term conventional as related to both these applications is intended to apply to the use of some form(s) of chemical propulsion system.

  5. Male brush-turkeys attempt sexual coercion in unusual circumstances.

    Science.gov (United States)

    Wells, David A; Jones, Darryl N; Bulger, David; Brown, Culum

    2014-07-01

    Sexual coercion by males is generally understood to have three forms: forced copulation, harassment and intimidation. We studied Australian brush-turkeys, Alectura lathami, to determine whether some male behaviours towards females at incubation mounds could be classified as aggressive, whether males were attempting sexual coercion and, if so, whether the coercion was successful. We found that some male behaviours towards females were significantly more likely to be followed by the cessation of female mound activity, and hence could be classified as aggressive, while others were significantly more likely to be followed by the commencement of female mound activity, and hence could be classified as enticing. Copulation was preceded by higher rates of male enticement and by higher rates of certain types of male aggression. It therefore seemed that males were attempting sexual coercion. There was little evidence, however, that this combination of coercion and enticement was successful in obtaining copulations. While forced copulation did occur, it was infrequent, and no evidence could be found for intimidation. We conclude that harassment is the primary form of sexual coercion by male brush-turkeys. Although sexual coercion is understood to be a sub-optimal tactic, brush-turkey sexual coercion was employed as a primary tactic by dominant males who owned incubation mounds. One possible explanation for this apparent paradox is that aggression is the default solution for social conflicts in this species, and hence can be interpreted as a behavioural syndrome. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Technology of high-speed combined machining with brush electrode

    Science.gov (United States)

    Kirillov, O. N.; Smolentsev, V. P.; Yukhnevich, S. S.

    2018-03-01

    The new method was proposed for high-precision dimensional machining with a brush electrode when the true position of bundles of metal wire is adjusted by means of creating controlled centrifugal forces appeared due to the increased frequency of rotation of a tool. There are the ultimate values of circumferential velocity at which the bundles are pressed against a machined area of a workpiece in a stable manner despite the profile of the machined surface and variable stock of the workpiece. The special aspects of design of processing procedures for finishing standard parts, including components of products with low rigidity, are disclosed. The methodology of calculation and selection of processing modes which allow one to produce high-precision details and to provide corresponding surface roughness required to perform finishing operations (including the preparation of a surface for metal deposition) is presented. The production experience concerned with the use of high-speed combined machining with an unshaped tool electrode in knowledge-intensive branches of the machine-building industry for different types of production is analyzed. It is shown that the implementation of high-speed dimensional machining with an unshaped brush electrode allows one to expand the field of use of the considered process due to the application of a multipurpose tool in the form of a metal brush, as well as to obtain stable results of finishing and to provide the opportunities for long-term operation of the equipment without its changeover and readjustment.

  7. Methylation analysis of CMTM3 and DUSP1 gene promoters in high-quality brush hair in the Yangtze River delta white goat.

    Science.gov (United States)

    Qiang, Wang; Guo, Haiyan; Li, Yongjun; Shi, Jianfei; Yin, Xiuyuan; Qu, Jingwen

    2018-08-20

    The Yangtze River delta white goat is the only goat breed that produces high-quality brush hair, which is specifically used in top-grade writing brushes. Previous studies have indicated that the CMTM3 and DUSP1 genes are involved in the growth and cycle of high-quality brush hair, and these genes are thought to be involved in the formation of high-quality brush hair traits. In this study, we investigated the relationship between methylation of CMTM3 and DUSP1 and such traits. The results indicated that the relative expression levels of the CMTM3 and DUSP1 genes were higher in non-high-quality brush hair than in high-quality brush hair. Furthermore, the CpG sites of the DUSP1 gene were not methylated, and the methylation level of CMTM3 was negatively correlated with the gene expression level. We believe that the DUSP1 gene regulates the formation of high-quality brush hair by non-methylated, and that methylation of the CMTM3 gene results in a decrease in its expression, causing an increase in the activity of the androgen receptor and the level of androgen. This high androgen level promotes the growth of high-quality brush hair. These study results provide a theoretical basis for further elucidating the molecular mechanism of the formation of high-quality brush hair characteristics, and provide scientific reference for the molecular breeding of high-quality brush hair. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Tethered Contactless Mobile Nuclear Environment Monitoring Robot

    International Nuclear Information System (INIS)

    Choi, S. Y.; Lee, E. S.; Lee, Kun J.; Kim, Su H.; Rim, C. T.

    2013-01-01

    In fact, the nuclear environment monitoring is significantly crucial for early detection of NPP accident, radiological emergency, the estimation of radiation exposure to nearby residents as well as the long term radioactivity. In the UAE, the nuclear environment monitoring is, however, quite challenging because sampling locations are far from NPPs and the outdoor temperature and humidity are very high for NPP workers to collect soil, air, and water samples. Therefore, nuclear environment monitoring robots (Nubos) are strongly needed for the NPPs in the UAE. The Nubos can be remotely controlled to collect samples in extreme environment instead of NPP workers. Moreover, the Nubos can be unmanned ground vehicles (UGVs), unmanned aerial vehicles (UAVs) and unmanned marine vehicles (UMVs) to collect soil, air, and water samples, respectively. In this paper, the prototype development of UGV type Nubos using power cable for a long distance power delivery, called Tethered contactless mobile Nubo is introduced and validated by experiments. In this paper, the prototype development of Tethered Contactless Mobile (TeCoM) Nubo, which can be powered continuously within several km distance and avoid tangled cable, and the indoor test are finished. As further works, outdoor demonstration and a grand scale R and D proposal of practical Nubo will be proceeded

  9. Tethered Contactless Mobile Nuclear Environment Monitoring Robot

    Energy Technology Data Exchange (ETDEWEB)

    Choi, S. Y.; Lee, E. S.; Lee, Kun J.; Kim, Su H.; Rim, C. T. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-05-15

    In fact, the nuclear environment monitoring is significantly crucial for early detection of NPP accident, radiological emergency, the estimation of radiation exposure to nearby residents as well as the long term radioactivity. In the UAE, the nuclear environment monitoring is, however, quite challenging because sampling locations are far from NPPs and the outdoor temperature and humidity are very high for NPP workers to collect soil, air, and water samples. Therefore, nuclear environment monitoring robots (Nubos) are strongly needed for the NPPs in the UAE. The Nubos can be remotely controlled to collect samples in extreme environment instead of NPP workers. Moreover, the Nubos can be unmanned ground vehicles (UGVs), unmanned aerial vehicles (UAVs) and unmanned marine vehicles (UMVs) to collect soil, air, and water samples, respectively. In this paper, the prototype development of UGV type Nubos using power cable for a long distance power delivery, called Tethered contactless mobile Nubo is introduced and validated by experiments. In this paper, the prototype development of Tethered Contactless Mobile (TeCoM) Nubo, which can be powered continuously within several km distance and avoid tangled cable, and the indoor test are finished. As further works, outdoor demonstration and a grand scale R and D proposal of practical Nubo will be proceeded.

  10. Stability analysis and trend study of a balloon tethered in a wind, with experimental comparisons

    Science.gov (United States)

    Redd, L. T.; Bland, S. R.; Bennett, R. M.

    1973-01-01

    A stability analysis and trend study for a balloon tethered in a steady wind are presented. The linearized, stability-derivative type analysis includes balloon aerodynamics, buoyancy, mass (including apparent mass), and static forces resulting from the tether cable. The analysis has been applied to a balloon 7.64 m in length, and the results are compared with those from tow tests of this balloon. This comparison shows that the analysis gives reasonable predictions for the damping, frequencies, modes of motion, and stability boundaries exhibited by the balloon. A trend study for the 7.64-m balloon was made to illustrate how the stability boundaries are affected by changes in individual stability parameters. The trends indicated in this study may also be applicable to many other tethered-balloon systems.

  11. Tethered by Self-Generated Flow: Mucus String Augmented Feeding Current Generation in Larval Oysters

    Science.gov (United States)

    Jiang, H.; Wheeler, J.; Anderson, E.

    2016-02-01

    Marine zooplankton live in a nutritionally dilute environment. To survive, they must process an enormous volume of water relative to their own body volume for food. To achieve this, many zooplankters including copepods, invertebrate larvae, and protists create a feeding current to concentrate and transport food items to their food gathering structures. To enhance the efficiency of the feeding current, these zooplankters often rely on certain "tethering" mechanisms to retard their translational motion for producing a strong feeding current. The tethering force may include excess weight due to gravity, force from attachment to solid surfaces, and drag experienced by strategically placed morphological structures. Larval oysters are known from previous studies to release mucus strings during feeding, presumably for supplying a tethering force to enhance their feeding-current efficiency. But the underlying mechanism is unclear. In this study, we used a high-speed microscale imaging system (HSMIS) to observe the behavior of freely swimming and feeding larval oysters. We also used HSMIS to measure larval imposed feeding currents via a micro-particle image velocimetry (µPIV) technique. HSMIS allows observations along a vertically oriented focal plane in a relatively large water vessel with unprecedented spatial and temporal resolutions. Our high-speed videos show that a feeding larval oyster continuously released a long mucus string into its feeding current that flows downward; the feeding current subsequently dragged the mucus string downward. Analysis of our µPIV data combined with a hydrodynamic model further suggests that the drag force experienced by the mucus string in the feeding current contributes significantly to the tethering force required to generate the feeding current. Thus, mucus strings in larval oysters act as "anchors" in larval self-generated flow to actively tether the feeding larvae.

  12. Myocardial Infarction Alters Adaptation of the Tethered Mitral Valve

    NARCIS (Netherlands)

    Dal-Bianco, Jacob P; Aikawa, Elena; Bischoff, Joyce; Guerrero, J Luis; Hjortnaes, Jesper; Beaudoin, Jonathan; Szymanski, Catherine; Bartko, Philipp E; Seybolt, Margo M; Handschumacher, Mark D; Sullivan, Suzanne; Garcia, Michael L; Mauskapf, Adam; Titus, James S; Wylie-Sears, Jill; Irvin, Whitney S; Chaput, Miguel; Messas, Emmanuel; Hagège, Albert A; Carpentier, Alain; Levine, Robert A

    2016-01-01

    BACKGROUND: In patients with myocardial infarction (MI), leaflet tethering by displaced papillary muscles induces mitral regurgitation (MR), which doubles mortality. Mitral valves (MVs) are larger in such patients but fibrosis sets in counterproductively. The investigators previously reported that

  13. Tooth brushing, tongue cleaning and snacking behaviour of dental ...

    African Journals Online (AJOL)

    2010-08-12

    Aug 12, 2010 ... frequency, duration and technique of tooth brushing and tongue cleaning as well as information on ... All the students in Year 1Б4 were included in the study. .... agents which are beneficial for prevention and treatment.

  14. [Surface roughness and gloss of novel flowable composites after polishing and simulated brushing wear].

    Science.gov (United States)

    Wang, R L; Yuan, C Y; Pan, Y X; Tian, F C; Wang, Z H; Wang, X Y

    2017-04-09

    Objective: To investigate surface properties of novel flowable composites after polishing and simulated brushing wear, compared to their pasty counterpart. Methods: Composites employed in this study were: three flowable composites (A1: Clearfil Majesty ES Flow; B1: Beautifil Flow Plus F00; C1: Filtek Bulk Fill) and three paste composites (A2: Clearfil Majesty; B2: Beautifil; C2: Filtek Z350. Eleven disk-shaped specimens were made for each material. The specimens were cured, then subjected to sandpaper finishing for 20 s, one-step polishing for 30 s, finally subjected to simulated brushing for 10 000 cycles. Surface roughness and glossiness were measured before finishing, after finishing, after polishing, after 5 000 brushing cycles and after 10 000 brushing cycles, respectively. Data obtained were analyzed using two-way ANOVA method. Scanning electron microscope was employed to examine the microscopic appearance of each material. Results: Surface roughness (0.11~0.22 μm) and glossiness (74.25~86.48 GU) of each material were similar after one-step polishing. After brushing simulation, roughness increased significantly and glossiness decreased significantly for each material ( Pgloss ([50.68±1.58] GU) after final wear ( P< 0.05). Flowable composites of group A1 and B1 tested in the present setup showed better surface properties compared to their pasty counterpart (group A2 and B2). Conclusions: Within the limit of this study, flowable composites tested in the present research can obtain similar surface polish or even better than the paste composite counterpart.

  15. Thermo-responsive and fluorescent cellulose nanocrystals grafted with polymer brushes

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Weibing [Nanjing Forestry Univ. (China); Georgia Inst. of Technology, Atlanta, GA (United States); Huang, Fang [Georgia Inst. of Technology, Atlanta, GA (United States); Pan, Shaobo [Georgia Inst. of Technology, Atlanta, GA (United States); Mu, Wei [Georgia Inst. of Technology, Atlanta, GA (United States); Meng, Xianzhi [Georgia Inst. of Technology, Atlanta, GA (United States); Yang, Haitao [Hubei Univ. of Technology, Wuhan (China); Xu, Zhaoyang [Nanjing Forestry Univ. (China); Ragauskas, Arthur J. [Georgia Inst. of Technology, Atlanta, GA (United States); Deng, Yulin [Georgia Inst. of Technology, Atlanta, GA (United States)

    2014-11-24

    Fluorescent and thermo-responsive cellulose nanocrystals (CNCs) with tuned polymer brushes were preparedviasurface initiated activators generated by electron transfer for atom transfer radical polymerization.

  16. Development of a Tethered Formation Flight Testbed for ISS, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The development of a testbed for the development and demonstration of technologies needed by tethered formation flying satellites is proposed. Such a testbed would...

  17. Improved curvature-based inpainting applied to fine art: recovering van Gogh's partially hidden brush strokes

    Science.gov (United States)

    Kuang, Yubin; Stork, David G.; Kahl, Fredrik

    2011-03-01

    Underdrawings and pentimenti-typically revealed through x-ray imaging and infrared reflectography-comprise important evidence about the intermediate states of an artwork and thus the working methods of its creator.1 To this end, Shahram, Stork and Donoho introduced the De-pict algorithm, which recovers layers of brush strokes in paintings with open brush work where several layers are partially visible, such as in van Gogh's Self portrait with a grey felt hat.2 While that preliminary work served as a proof of concept that computer image analytic methods could recover some occluded brush strokes, the work needed further refinement before it could be a tool for art scholars. Our current work makes several steps to improve that algorithm. Specifically, we refine the inpainting step through the inclusion of curvature-based constraints, in which a mathematical curvature penalty biases the reconstruction toward matching the artist's smooth hand motion. We refine and test our methods using "ground truth" image data: passages of four layers of brush strokes in which the intermediate layers were recorded photographically. At each successive top layer (currently identified by the user), we used k-means clustering combined with graph cuts to obtain chromatically and spatially coherent segmentation of brush strokes. We then reconstructed strokes at the deeper layer with our new curvature-based inpainting algorithm based on chromatic level lines. Our methods are clearly superior to previous versions of the De-pict algorithm on van Gogh's works giving smoother, natural strokes that more closely match the shapes of unoccluded strokes. Our improved method might be applied to the classic drip paintings of Jackson Pollock, where the drip work is more open and the physics of splashing paint ensures that the curvature more uniform than in the brush strokes of van Gogh.

  18. Profilometric analysis of two composite resins' surface repolished after tooth brush abrasion with three polishing systems.

    Science.gov (United States)

    Uppal, Mudit; Ganesh, Arathi; Balagopal, Suresh; Kaur, Gurleen

    2013-07-01

    To evaluate the effect of three polishing protocols that could be implemented at recall on the surface roughness of two direct esthetic restorative materials. Specimens (n = 40) measuring 8 mm (length) × 5 mm (width) × 4 mm (height) were fabricated in an acrylic mold using two light-cured resin-based materials (microfilled composite and microhybrid composite). After photopolymerization, all specimens were finished and polished with one of three polishing protocols (Enhance, One Gloss, and Sof-Lex polishing systems). The average surface roughness of each treated specimen was determined using 3D optical profilometer. Next all specimens were brushed 60,000 times with nylon bristles at 7200 rpm using crosshead brushing device with equal parts of toothpaste and water used as abrasive medium. The surface roughness of each specimen was measured after brushing followed by repolishing with one of three polishing protocols, and then, the final surface roughness values were determined. The data were analyzed using one-way and two-factor analysis of variance (ANOVA) and Tukey's honestly significant difference (HSD). Significant difference (P < 0.05) in surface roughness was observed. Simulated brushing following initial polishing procedure significantly roughened the surface of restorative material (P < 0.05). Polishing protocols can be used to restore a smooth surface on esthetic restorative materials following simulated tooth brushing.

  19. Materials for advancement of MXER tether design (1000-371), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — There exist a need to develop, identify, and classify various materials that can be used in the fabrication of electrodynamic tethers for various applications. These...

  20. Implementation Options for the PROPEL Electrodynamic Tether Demonstration Mission

    Science.gov (United States)

    Bilen, Sven G.; Johnson, C. Les; Gilchrist, Brian E.; Hoyt, Robert P.; Elder, Craig H.; Fuhrhop, Keith P.; Scadera, Michael; Stone, Nobie

    2014-01-01

    The PROPEL ("Propulsion using Electrodynamics") flight demonstration mission concept will demonstrate the use of an electrodynamic tether (EDT) for generating thrust, which will allow the propulsion system to overcome the limitations of the rocket equation. The mission concept has been developed by a team of government, industry, and academia partners led by NASA Marshall Space Flight Center (MSFC). PROPEL is being designed for versatility of the EDT system with multiple end users in mind and to be flexible with respect to platform. Previously, we reported on a comprehensive mission design for PROPEL with a mission duration of six months or longer with multiple mission goals including demonstration of significant boost, deboost, inclination change, and drag make-up activities. To explore a range of possible configurations, primarily driven by cost considerations, other mission concept designs have been pursued. In partnership with the NASA's Office of Chief Technologist (OCT) Game Changing Program, NASA MSFC Leadership, and the MSFC Advanced Concepts Office, a mission concept design was developed for a near-term EDT propulsion flight validation mission. The Electrodynamic Tether Propulsion Study (ETPS) defined an EDT propulsion system capable of very large delta-V for use on future missions developed by NASA, DoD, and commercial customers. To demonstrate the feasibility of an ETPS, the study focused on a space demonstration mission concept design with configuration of a pair of tethered satellite busses, one of which is the Japanese H-II Transfer Vehicle (HTV). The HTV would fly its standard ISS resupply mission. When resupply mission is complete, the ISS reconfigures and releases the HTV to perform the EDT experiment at safe orbital altitudes below the ISS. Though the focus of this particular mission concept design addresses a scenario involving the HTV or a similar vehicle, the propulsion system's capability is relevant to a number of applications, as noted above

  1. Phototriggered functionalization of hierarchically structured polymer brushes

    Czech Academy of Sciences Publication Activity Database

    de los Santos Pereira, Andres; Kostina, Nina Yu.; Bruns, M.; Rodriguez-Emmenegger, Cesar; Barner-Kowollik, C.

    2015-01-01

    Roč. 31, č. 21 (2015), s. 5899-5907 ISSN 0743-7463 R&D Projects: GA ČR(CZ) GJ15-09368Y; GA MŠk(CZ) ED1.1.00/02.0109 Grant - others:OPPK(XE) CZ.2.16/3.1.00/21545 Program:OPPK Institutional support: RVO:61389013 Keywords : polymer brushes * antifouling * click chemistry Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.993, year: 2015

  2. Antifouling polymer brushes displaying antithrombogenic surface properties

    Czech Academy of Sciences Publication Activity Database

    de los Santos Pereira, Andres; Sheikh, S.; Blaszykowski, C.; Pop-Georgievski, Ognen; Fedorov, K.; Thompson, M.; Rodriguez-Emmenegger, Cesar

    2016-01-01

    Roč. 17, č. 3 (2016), s. 1179-1185 ISSN 1525-7797 R&D Projects: GA ČR(CZ) GJ15-09368Y; GA MŠk(CZ) ED1.1.00/02.0109 Grant - others:OPPK(XE) CZ.2.16/3.1.00/21545 Program:OPPK Institutional support: RVO:61389013 Keywords : polymer brushes * surface characterization * antifouling surfaces Subject RIV: BO - Biophysics Impact factor: 5.246, year: 2016

  3. Co-adhesion and removal of adhering bacteria from salivary pellicles by three different modes of brushing

    NARCIS (Netherlands)

    Yang, J; Belder, GF; Busscher, HJ; Bos, R.R.M.

    2001-01-01

    This study compares removal of pairs of co-adhering and non-co-adhering oral actinomyces and streptococci by hand, electric and sonic brushing from salivary pellicles. In addition, re-deposition of a co-adhering and non-co-adhering streptococcal strain to brushed pellicles was studied. First,

  4. Production rates for United States Forest Service brush disposal planning in the northern Rocky Mountains

    Science.gov (United States)

    Dan Loeffler; Stu Hoyt; Nathaniel Anderson

    2017-01-01

    Timber harvesting operations generate brush and other vegetative debris, which often has no marketable value. In many western U.S. forests, these materials represent a fire hazard and a potential threat to forest health and must be removed or burned for disposal. Currently, there is no established, consistent method to estimate brush disposal production rates in the U....

  5. Cytology evaluation for brushing in biliary and pancreatic stenosis during endoscopic cholangiopancreatography

    International Nuclear Information System (INIS)

    Ruiz, Mario H; Castano, Rodrigo; Alvarez, Oscar A; Velez, Alejandro; Munera, Veronica

    2002-01-01

    No surgical pathologic confirmation of malignant bile duct strictures is desirable for defining subsequent treatment and prognosis. Endoscopic retrograde cholangiopancreatography is frequently performed in patients suspected of having pancreaticobiliary obstruction, but there exists no standardized method or instruments for defining benign or malignant nature of obstructing lesions by ERCP. We prospectively evaluated the yields of endoscopic retrograde brush cytology for the diagnosis of malignant bile and pancreatic duct strictures. Fluoroscopically guided endobiliary brush cytology was performed during endoscopic retrograde cholangiopancreatography in 29 consecutive patients, 20 with malignant strictures and 9 with benign stricture. A single pathologist classified the results of these studies as positive, or negative for malignancy. The sensitivities of the procedure were 69%. Specificity proved excellent, 100%. Two major complications that occurred in the same patient were acute pancreatitis in a patient with chronic pancreatitis and bleeding from pancreatic duct. Both were managed medically and improved. This study indicates that endoscopic retrograde brush cytology alone may be sufficient in daily practice, to differentiate against benign and malignant biliary or pancreatic stenosis

  6. Folding of multidomain proteins: biophysical consequences of tethering even in apparently independent folding.

    Science.gov (United States)

    Arviv, Oshrit; Levy, Yaakov

    2012-12-01

    Most eukaryotic and a substantial fraction of prokaryotic proteins are composed of more than one domain. The tethering of these evolutionary, structural, and functional units raises, among others, questions regarding the folding process of conjugated domains. Studying the folding of multidomain proteins in silico enables one to identify and isolate the tethering-induced biophysical determinants that govern crosstalks generated between neighboring domains. For this purpose, we carried out coarse-grained and atomistic molecular dynamics simulations of two two-domain constructs from the immunoglobulin-like β-sandwich fold. Each of these was experimentally shown to behave as the "sum of its parts," that is, the thermodynamic and kinetic folding behavior of the constituent domains of these constructs seems to occur independently, with the folding of each domain uncoupled from the folding of its partner in the two-domain construct. We show that the properties of the individual domains can be significantly affected by conjugation to another domain. The tethering may be accompanied by stabilizing as well as destabilizing factors whose magnitude depends on the size of the interface, the length, and the flexibility of the linker, and the relative stability of the domains. Accordingly, the folding of a multidomain protein should not be viewed as the sum of the folding patterns of each of its parts, but rather, it involves abrogating several effects that lead to this outcome. An imbalance between these effects may result in either stabilization or destabilization owing to the tethering. Copyright © 2012 Wiley Periodicals, Inc.

  7. Organic monolayers and fluoropolymer brushes : functionalization, stability and tribology

    NARCIS (Netherlands)

    Bhairamadgi, N.S.

    2014-01-01

    This thesis deals with the adhesion and friction properties of densely grafted and covalently bound fluoropolymer brushes on silicon surfaces with varying thickness and fluorine content. A novel surface-functionalizing method is described using the thiol-yne click (TYC) reaction. The TYC

  8. Biomimetic chimeric peptide-tethered hydrogels for human mesenchymal stem cell delivery.

    Science.gov (United States)

    Shim, Gayong; Kim, Gunwoo; Choi, Junhyeok; Yi, TacGhee; Cho, Yun Kyoung; Song, Sun Uk; Byun, Youngro; Oh, Yu-Kyoung

    2015-12-01

    Here, we report a chimeric peptide-tethered fibrin hydrogel scaffold for delivery of human mesenchymal stem cells (hMSC). Osteopontin-derived peptide (OP) was used as an hMSC-tethering moiety. OP showed hMSC adhesion properties and enhanced hMSC proliferation. A natural fibrin-binding protein-derived peptide (FBP) was tested for its ability to tether hMSC to the fibrin gel matrix. FBP loading on fibrin gels was 8.2-fold higher than that of a scrambled peptide (scFBP). FBP-loaded fibrin gels were retained at injection sites longer than scFBP-loaded fibrin gels, showing a 15.9-fold higher photon intensity of fluorescent FBP-grafted fibrin gels than fluorescent scFBP-loaded fibrin gels 48 h after injection. On the basis of the fibrin gel-binding properties of FBP and the hMSC-binding and proliferation-supporting properties of OP, we constructed chimeric peptides containing FBP and OP linked with a spacer (FBPsOP). Four days after transplantation, the survival of hMSC in FBPsOP-grafted fibrin gels was 3.9-fold higher than hMSC in fibrin gels alone. Our results suggest the potential of FBPsOP-grafted fibrin gels as a bioactive delivery system for enhanced survival of stem cells. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Acquisition of Human Operation Characteristics for Kite-based Tethered Flying Robot using Human Operation Data

    OpenAIRE

    Todoroki, Chiaki; Takahashi, Yasutake; Nakamura, Takayuki

    2015-01-01

    This paper shows human skill acquisition systems to control the kite-based tethered flying robot. The kite-based tethered flying robot has been proposed as a flying observation system with long-term activity capability[1]. It is a relatively new system and aimed to complement other information gathering systems using a balloon or an air vehicle. This paper shows some approaches of human operation characteristics acquisition based on fuzzy learning controller, knearest neighbor algorithm, and ...

  10. Preparation of polystyrene brush film by radical chain-transfer polymerization and micromechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Jing [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate School of Chinese Academy of Sciences, Beijing 100039 (China); Chen Miao [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)], E-mail: miaochen99@yahoo.com; An Yanqing [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate School of Chinese Academy of Sciences, Beijing 100039 (China); Liu Jianxi [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Yan Fengyuan [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)], E-mail: fyyan@lzb.ac.cn

    2008-12-30

    A radical chain-transfer polymerization technique has been applied to graft-polymerize brushes of polystyrene (PSt) on single-crystal silicon substrates. 3-Mercapto-propyltrimethoxysilane (MPTMS), as a chain-transfer agent for grafting, was immobilized on the silicon surface by a self-assembling process. The structure and morphology of the graft-functionalized silicon surfaces were characterized by the means of contact-angle measurement, ellipsometric thickness measurement, Fourier transformation infrared (FTIR) spectroscopy, and atomic force microscopy (AFM). The nanotribological and micromechanical properties of the as-prepared polymer brush films were investigated by frictional force microscopy (FFM), force-volume analysis and scratch test. The results indicate that the friction properties of the grafted polymer films can be improved significantly by the treatment of toluene, and the chemically bonded polystyrene film exhibits superior scratch resistance behavior compared with the spin-coated polystyrene film. The resultant polystyrene brush film is expected to develop as a potential lubrication coating for microelectromechanical systems (MEMS)

  11. Control by damping Injection of Electrodynamic Tether System in an Inclined Orbit

    DEFF Research Database (Denmark)

    Larsen, Martin Birkelund; Blanke, Mogens

    2009-01-01

    dynamical system. Based on this model, a nonlinear controller is designed that will make the system asymptotically stable around its open-loop equilibrium. The control scheme handles the time-varying nature of the system in a suitable manner resulting in a large operational region. The performance...... of the closed loop system is treated using Floquet theory, investigating the closed loop properties for their dependency of the controller gain and orbit inclination.......Control of a satellite system with an electrodynamic tether as actuator is a time-periodic and underactuated control problem. This paper considers the tethered satellite in a Hamiltonian framework and determines a port-controlled Hamiltonian formulation that adequately describes the nonlinear...

  12. Preparing polymer brushes on polytetrafluoroethylene films by free radical polymerization

    International Nuclear Information System (INIS)

    Sun Wei; Chen Yiwang; Deng Qilan; Chen Lie; Zhou Lang

    2006-01-01

    Films of polytetrafluoroethylene (PTFE) were exposed to sodium naphthalenide (Na/naphtha) etchant so as to defluorinate the surface for obtaining hydroxyl functionality. Surface-initiators were immobilized on the PTFE films by esterification of 4,4'-azobis(4-cyanopentanoic acid) (ACP) and the hydroxyl groups covalently linked to the surface. Grafting of polymer brushes on the PTFE films was carried out by the surface-initiated free radical polymerization. Homopolymers brushes of methyl methacrylate (MMA) were prepared by free radical polymerization from the azo-functionalized PTFE surface. The chemical composition and topography of the graft-functionalized PTFE surfaces were characterized by X-ray photoelectron spectroscopy (XPS), attenuated total reflectance (ATR) FT-IR spectroscopy and atomic force microscopy (AFM). Water contact angles on PTFE films were reduced by surface grafting of MMA

  13. Deep-apical tubules: dynamic lipid-raft microdomains in the brush-border region of enterocytes

    DEFF Research Database (Denmark)

    Hansen, Gert H; Pedersen, Jens; Niels-Christiansen, Lise-Lotte

    2003-01-01

    microdomains. Deep-apical tubules were positioned close to the actin rootlets of adjacent microvilli in the terminal web region, which had a diameter of 50-100 nm, and penetrated up to 1 microm into the cytoplasm. Markers for transcytosis, IgA and the polymeric immunoglobulin receptor, as well as the resident...... lipid raft-containing compartments, but little is otherwise known about these raft microdomains. We therefore studied in closer detail apical lipid-raft compartments in enterocytes by immunogold electron microscopy and biochemical analyses. Novel membrane structures, deep-apical tubules, were visualized...... brush-border enzyme aminopeptidase N, were present in these deep-apical tubules. We propose that deep-apical tubules are a specialized lipid-raft microdomain in the brush-border region functioning as a hub in membrane trafficking at the brush border. In addition, the sensitivity to cholesterol depletion...

  14. Tooth brushing, tongue cleaning and snacking behaviour of dental ...

    African Journals Online (AJOL)

    Objective: To determine the tooth brushing, tongue cleaning and snacking behaviour of dental technology and therapist students. Methods: A descriptive cross-sectional study of students of Federal School of Dental Therapy and Technology Enugu, Nigeria. Self-administered questionnaire was used to obtain information on ...

  15. Molecular aggregation states of poly{2-(perfluorooctyl)ethyl acrylate} polymer brush thin film analyzed by grazing incidence X-ray diffraction

    International Nuclear Information System (INIS)

    Yamaguchi, H; Honda, K; Takahara, A; Kobayashi, M; Morita, M; Masunaga, H; Sasaki, S; Takata, M; Sakata, O

    2009-01-01

    Fluoropolymer brush with crystalline side chains was prepared by surface-initiated atom transfer radical polymerization of 2-(perfluorooctyl)ethyl acrylate (FA-C 8 ) from a flat silicon substrate. The crystallization and the molecular aggregation structures of polymer side chain at the outermost surface and internal region in the brush film were characterized by grazing incidence X-ray diffraction (GIXD) measurement using two different incident angles of X-ray. At the air interface of PFA-C 8 brush film, the rod-like R f group was oriented perpendicular to the surface forming a hexagonal packing structure to reduce surface energy. In contrast, the oriented R f groups parallel to the substrate coexisted at the internal region in the brush. This unique depth dependence of crystalline state of the fluoropolymer brush was observed by surface-sensitive GIXD measurement.

  16. A Correlational Analysis of Tethered Swimming, Swim Sprint Performance and Dry-land Power Assessments.

    Science.gov (United States)

    Loturco, I; Barbosa, A C; Nocentini, R K; Pereira, L A; Kobal, R; Kitamura, K; Abad, C C C; Figueiredo, P; Nakamura, F Y

    2016-03-01

    Swimmers are often tested on both dry-land and in swimming exercises. The aim of this study was to test the relationships between dry-land, tethered force-time curve parameters and swimming performances in distances up to 200 m. 10 young male high-level swimmers were assessed using the maximal isometric bench-press and quarter-squat, mean propulsive power in jump-squat, squat and countermovement jumps (dry-land assessments), peak force, average force, rate of force development (RFD) and impulse (tethered swimming) and swimming times. Pearson product-moment correlations were calculated among the variables. Peak force and average force were very largely correlated with the 50- and 100-m swimming performances (r=- 0.82 and -0.74, respectively). Average force was very-largely/largely correlated with the 50- and 100-m performances (r=- 0.85 and -0.67, respectively). RFD and impulse were very-largely correlated with the 50-m time (r=- 0.72 and -0.76, respectively). Tethered swimming parameters were largely correlated (r=0.65 to 0.72) with mean propulsive power in jump-squat, squat-jump and countermovement jumps. Finally, mean propulsive power in jump-squat was largely correlated (r=- 0.70) with 50-m performance. Due to the significant correlations between dry-land assessments and tethered/actual swimming, coaches are encouraged to implement strategies able to increase leg power in sprint swimmers. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Brush Seals for Cryogenic Applications: Performance, Stage Effects, and Preliminary Wear Results in LN2 and LH2

    Science.gov (United States)

    Proctor, Margaret P.; Walker, James F.; Perkins, H. Douglas; Hoopes, Joan F.; Williamson, G. Scott

    1996-01-01

    Brush seals are compliant contacting seals and have significantly lower leakage than labyrinth seals in gas turbine applications. Their long life and low leakage make them candidates for use in rocket engine turbopumps. Brush seals, 50.8 mm (2 in.) in diameter with a nominal 127-micron (0.005-in.) radial interference, were tested in liquid nitrogen (LN2) and liquid hydrogen (LH2) at shaft speeds up to 35,000 and 65,000 rpm, respectively, and at pressure drops up to 1.21 MPa (175 psid) per brush. A labyrinth seal was also tested in liquid nitrogen to provide a baseline. The LN2 leakage rate of a single brush seal with an initial radial shaft interference of 127 micron (0.005 in.) measured one-half to one-third the leakage rate of a 12-tooth labyrinth seal with a radial clearance of 127 micron (0.005 in.). Two brushes spaced 7.21 micron (0.248 in.) apart leaked about one-half as much as a single brush, and two brushes tightly packed together leaked about three-fourths as much as a single brush. The maximum measured groove depth on the Inconel 718 rotor with a surface finish of 0.81 micron (32 microinch) was 25 micron (0.0010 in.) after 4.3 hr of shaft rotation in liquid nitrogen. The Haynes-25 bristles wore approximately 25 to 76 micron (0.001 to 0.003 in.) under the same conditions. Wear results in liquid hydrogen were significantly different. In liquid hydrogen the rotor did not wear, but the bristle material transferred onto the rotor and the initial 127 micron (0.005 in.) radial interference was consumed. Relatively high leakage rates were measured in liquid hydrogen. More testing is required to verify the leakage performance, to validate and calibrate analysis techniques, and to determine the wear mechanisms. Performance, staging effects, and preliminary wear results are presented.

  18. Normally Oriented Adhesion versus Friction Forces in Bacterial Adhesion to Polymer-Brush Functionalized Surfaces Under Fluid Flow

    NARCIS (Netherlands)

    Swartjes, Jan J. T. M.; Veeregowda, Deepak H.; van der Mei, Henny C.; Busscher, Henk J.; Sharma, Prashant K.

    2014-01-01

    Bacterial adhesion is problematic in many diverse applications. Coatings of hydrophilic polymer chains in a brush configuration reduce bacterial adhesion by orders of magnitude, but not to zero. Here, the mechanism by which polymer-brush functionalized surfaces reduce bacterial adhesion from a

  19. Single-Molecule Tethered Particle Motion: Stepwise Analyses of Site-Specific DNA Recombination

    Directory of Open Access Journals (Sweden)

    Hsiu-Fang Fan

    2018-05-01

    Full Text Available Tethered particle motion/microscopy (TPM is a biophysical tool used to analyze changes in the effective length of a polymer, tethered at one end, under changing conditions. The tether length is measured indirectly by recording the Brownian motion amplitude of a bead attached to the other end. In the biological realm, DNA, whose interactions with proteins are often accompanied by apparent or real changes in length, has almost exclusively been the subject of TPM studies. TPM has been employed to study DNA bending, looping and wrapping, DNA compaction, high-order DNA–protein assembly, and protein translocation along DNA. Our TPM analyses have focused on tyrosine and serine site-specific recombinases. Their pre-chemical interactions with DNA cause reversible changes in DNA length, detectable by TPM. The chemical steps of recombination, depending on the substrate and the type of recombinase, may result in a permanent length change. Single molecule TPM time traces provide thermodynamic and kinetic information on each step of the recombination pathway. They reveal how mechanistically related recombinases may differ in their early commitment to recombination, reversibility of individual steps, and in the rate-limiting step of the reaction. They shed light on the pre-chemical roles of catalytic residues, and on the mechanisms by which accessory proteins regulate recombination directionality.

  20. Quinine-Promoted, Enantioselective Boron-Tethered Diels-Alder Reaction by Anomeric Control of Transition State Conformation.

    Science.gov (United States)

    Scholl, Katie; Dillashaw, John; Timpy, Evan; Lam, Yu-Hong; DeRatt, Lindsey; Benton, Tyler R; Powell, Jacqueline P; Houk, Kendall N; Morgan, Jeremy B

    2018-05-01

    Diels-Alder reactions of tethered vinyl-metal species offer the opportunity to fashion highly functionalized diol intermediates for synthesis. We have developed the first enantioselective boron-tethered Diels-Alder reaction using quinine as a chiral promoter. Quinine recovery, enantioselectivity enhancement, and manipulation of the cyclohexene core are also investigated. DFT modeling calculations confirm the role of quinine as a bidentate ligand enhancing reaction rates. The enantioselectivity of the cycloaddition is proposed to originate from a boron-centered anomeric effect.

  1. Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use.

    Science.gov (United States)

    Fais, Laiza M G; Fernandes-Filho, Romeu B; Pereira-da-Silva, Marcelo A; Vaz, Luis G; Adabo, Gelson L

    2012-04-01

    To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride. Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm Ø×4 mm) were mirror-polished and treated according to 6 groups (n=6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (α=.05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (α=.05). cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29±0.55/2.33±0.17; IT, 2.24±0.46/2.02±0.38; IFT, 2.22±0.53/1.95±0.36; BW, 2.22±0.42/3.76±0.45; BT, 2.27±0.55/16.05±3.25; BFT, 2.27±0.51/22.39±5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79±0.25/2.01±0.25; IT, 1.61±0.13/1.74±0.19; IFT, 1.92±0.39/2.29±0.51; BW, 2.00±0.71/2.05±0.43; BT, 2.37±0.86/11.17±2.29; BFT, 1.83±0.50/15.73±1.78. No significant differences were seen after immersions (p>.05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p<.01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces. Exposure to toothpastes (immersion

  2. Cylindrical polymer brushes with dendritic side chains by iterative anionic reactions

    KAUST Repository

    Zhang, Hefeng

    2015-05-01

    We report in this paper an easy method for the synthesis of cylindrical polymer brushes with dendritic side chains through anionic reaction. The synthesis is accomplished by iteratively grafting a living block copolymer, polyisoprene-. b-polystyrenyllithium (PI-. b-PSLi), to the main chain and subsequently to the branches in a divergent way. PI segment is short and serves as a precursor for multifunctional branching unit. The grafting reaction involves two successive steps: i) epoxidation of internal double bonds of PI segments, either in main chain or side chains; ii) ring-opening addition to the resulting epoxy group by the living PI-. b-PSLi. Repeating the two steps affords a series of cylindrical polymer brushes with up to 3rd generation and extremely high molecular weight. The branching multiplicity depends on the average number of oxirane groups per PI segment, usually ca. 8 in the present work. The high branching multiplicity leads to tremendous increase in molecular weights of the cylindrical products with generation growth. Several series of cylindrical polymer brushes with tunable aspect ratios are prepared using backbones and branches with controlled lengths. Shape anisotropy is investigated in dilute solution using light scattering technique. Worm-like single molecular morphology with large persistence length is observed on different substrates by atomic force microscopy.

  3. A Novel Method for Sensorless Speed Detection of Brushed DC Motors

    Directory of Open Access Journals (Sweden)

    Ernesto Vazquez-Sanchez

    2016-12-01

    Full Text Available Many motor applications require accurate speed measurement. For brushed dc motors, speed can be measured with conventional observers or sensorless observers. Sensorless observers have the advantage of not requiring any external devices to be attached to the motor. Instead, voltage and/or current are measured and used to estimate the speed. The sensorless observers are usually divided into two groups: those based on the dynamic model, and those based on the ripple component. This paper proposes a method that measures the current of brushed dc motors and analyses the position of its spectral components. From these spectral components, the method estimates the motor speed. Three tests, performed each with the speeds ranging from 2000 to 3000 rpm either at constant-speed, at slowly changing speeds, or at rapidly changing speeds, showed that the average error was below 1 rpm and that the deviation error was below 1.5 rpm. The proposed method: (i is a novel method that is not based on either the dynamic model or on the ripple component; (ii requires only the measurement of the current for the speed estimation; (iii can be used for brushed dc (direct current motors with a large number of coils; and (iv achieves a low error in the speed estimation.

  4. UV-Curable Hybrid Nanocomposite Coating to Protect Tether Polymer Materials, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — To address the NASA need for coatings to protect and strengthen tether materials for Momentum-exchange Electrodynamic Reboost (MXER) technology, Luminit, LLC,...

  5. Mini-open spinal column shortening for the treatment of adult tethered cord syndrome.

    Science.gov (United States)

    Safaee, Michael M; Winkler, Ethan A; Chou, Dean

    2017-10-01

    Tethered cord syndrome (TCS) is a challenging entity characterized by adhesions at the caudal spinal cord that prevent upward movement during growth and result in stretching of the cord with a concomitant constellation of neurologic symptoms. Although growth in height stops in adulthood, some patients still develop progressive symptoms; many underwent detethering as a child or adolescent, resulting in significant scar tissue and re-tethering. Recent strategies have focused on spinal column shortening to reduce tension on the spinal cord without exposing the previous de-tethering site. Mini-open and minimally invasive approaches avoid the large dissection and exposure associated with traditional approaches and are associated with reduced blood loss, shorter hospital stay, and similar outcomes when compared to conventional open approaches. We describe a technique for mini-open spinal column shortening. Using intraoperative navigation pedicle screws were placed at T10, T11, L1, and L2. A mini-open 3-column "egg shell" decancellation osteotomy of T12 was performed through a transpedicular approach with preservation of the superior and inferior endplates. This procedure was performed on a 28year old male with recurrent TCS and neurogenic bladder. Postoperative imaging showed a reduction in spinal column length of 1.5cm and evidence of decreased tension on the spinal cord. At last follow-up he was recovering well with improved urinary function. Spinal column shortening for adult TCS can be safely achieved through a mini-open approach. Future studies should compare the efficacy of this technique to both traditional de-tethering and open spinal column shortening. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Screening effects in a polyelectrolyte brush: self-consistent-field theory

    NARCIS (Netherlands)

    Zhulina, E.B.; Klein Wolterink, J.; Borisov, O.V.

    2000-01-01

    We have developed an analytical self-consistent-field (SCF) theory describing conformations of weakly charged polyelectrolyte chains tethered to the solid-liquid interface and immersed in a solution of low molecular weight salt. Depending on the density of grafting of the polyelectrolytes to the

  7. Damage of target edges in brush-like geometry in the course of ELM-like plasma pulses in QSPA Kh-50

    Science.gov (United States)

    Makhlaj, V. A.; Garkusha, I. E.; Aksenov, N. N.; Bazylev, B.; Byrka, O. V.; Chebotarev, V. V.; Landman, I.; Herashchenko, S. S.; Staltsov, V. V.

    2015-08-01

    Castellated edges of macro-brush armour elements of ITER divertor can be a source of molten/solid dust particles which are injected into the plasma. The targets that combined in brush-like geometry have been irradiated under different inclination angles in QSPA Kh-50. The cubic brushes element has typical size of 1 cm. The titanium was used to investigate dynamics of mountains' formation. The onset of dust particles ejection from the exposed castellated targets has been studied. Formation of resolidified bridges through the gaps of brush-like targets due to the melt motion is studied in dynamics. With following plasma impacts such resolidified bridges became additional source of dust.

  8. Damage of target edges in brush-like geometry in the course of ELM-like plasma pulses in QSPA Kh-50

    International Nuclear Information System (INIS)

    Makhlaj, V.A.; Garkusha, I.E.; Aksenov, N.N.; Bazylev, B.; Byrka, O.V.; Chebotarev, V.V.; Landman, I.; Herashchenko, S.S.; Staltsov, V.V.

    2015-01-01

    Castellated edges of macro-brush armour elements of ITER divertor can be a source of molten/solid dust particles which are injected into the plasma. The targets that combined in brush-like geometry have been irradiated under different inclination angles in QSPA Kh-50. The cubic brushes element has typical size of 1 cm. The titanium was used to investigate dynamics of mountains’ formation. The onset of dust particles ejection from the exposed castellated targets has been studied. Formation of resolidified bridges through the gaps of brush-like targets due to the melt motion is studied in dynamics. With following plasma impacts such resolidified bridges became additional source of dust

  9. Damage of target edges in brush-like geometry in the course of ELM-like plasma pulses in QSPA Kh-50

    Energy Technology Data Exchange (ETDEWEB)

    Makhlaj, V.A., E-mail: makhlay@ipp.kharkov.ua [Institute of Plasma Physics of the NSC KIPT, 61108 Kharkov (Ukraine); Garkusha, I.E.; Aksenov, N.N. [Institute of Plasma Physics of the NSC KIPT, 61108 Kharkov (Ukraine); Bazylev, B. [Karlsruhe Institute of Technology (KIT), IHM, 76344 Karlsruhe (Germany); Byrka, O.V.; Chebotarev, V.V. [Institute of Plasma Physics of the NSC KIPT, 61108 Kharkov (Ukraine); Landman, I. [Karlsruhe Institute of Technology (KIT), IHM, 76344 Karlsruhe (Germany); Herashchenko, S.S.; Staltsov, V.V. [Institute of Plasma Physics of the NSC KIPT, 61108 Kharkov (Ukraine)

    2015-08-15

    Castellated edges of macro-brush armour elements of ITER divertor can be a source of molten/solid dust particles which are injected into the plasma. The targets that combined in brush-like geometry have been irradiated under different inclination angles in QSPA Kh-50. The cubic brushes element has typical size of 1 cm. The titanium was used to investigate dynamics of mountains’ formation. The onset of dust particles ejection from the exposed castellated targets has been studied. Formation of resolidified bridges through the gaps of brush-like targets due to the melt motion is studied in dynamics. With following plasma impacts such resolidified bridges became additional source of dust.

  10. Growing Embossed Nanostructures of Polymer Brushes on Wet-Etched Silicon Templated via Block Copolymers

    Science.gov (United States)

    Lu, Xiaobin; Yan, Qin; Ma, Yinzhou; Guo, Xin; Xiao, Shou-Jun

    2016-02-01

    Block copolymer nanolithography has attracted enormous interest in chip technologies, such as integrated silicon chips and biochips, due to its large-scale and mass production of uniform patterns. We further modified this technology to grow embossed nanodots, nanorods, and nanofingerprints of polymer brushes on silicon from their corresponding wet-etched nanostructures covered with pendent SiHx (X = 1-3) species. Atomic force microscopy (AFM) was used to image the topomorphologies, and multiple transmission-reflection infrared spectroscopy (MTR-IR) was used to monitor the surface molecular films in each step for the sequential stepwise reactions. In addition, two layers of polymethacrylic acid (PMAA) brush nanodots were observed, which were attributed to the circumferential convergence growth and the diffusion-limited growth of the polymer brushes. The pH response of PMAA nanodots in the same region was investigated by AFM from pH 3.0 to 9.0.

  11. Tuning peptide self-assembly by an in-tether chiral center

    Science.gov (United States)

    Hu, Kuan; Xiong, Wei; Li, Hu; Zhang, Pei-Yu; Yin, Feng; Zhang, Qianling; Jiang, Fan; Li, Zigang

    2018-01-01

    The self-assembly of peptides into ordered nanostructures is important for understanding both peptide molecular interactions and nanotechnological applications. However, because of the complexity and various self-assembling pathways of peptide molecules, design of self-assembling helical peptides with high controllability and tunability is challenging. We report a new self-assembling mode that uses in-tether chiral center-induced helical peptides as a platform for tunable peptide self-assembly with good controllability. It was found that self-assembling behavior was governed by in-tether substitutional groups, where chirality determined the formation of helical structures and aromaticity provided the driving force for self-assembly. Both factors were essential for peptide self-assembly to occur. Experiments and theoretical calculations indicate long-range crystal-like packing in the self-assembly, which was stabilized by a synergy of interpeptide π-π and π-sulfur interactions and hydrogen bond networks. In addition, the self-assembled peptide nanomaterials were demonstrated to be promising candidate materials for applications in biocompatible electrochemical supercapacitors.

  12. Lung malignancy: Diagnostic accuracies of bronchoalveolar lavage, bronchial brushing, and fine needle aspiration cytology

    Science.gov (United States)

    Sareen, Rateesh; Pandey, C L

    2016-01-01

    Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992

  13. Photodegradable neutral-cationic brush block copolymers for nonviral gene delivery.

    Science.gov (United States)

    Hu, Xianglong; Li, Yang; Liu, Tao; Zhang, Guoying; Liu, Shiyong

    2014-08-01

    We report on the fabrication of a photodegradable gene-delivery vector based on PEO-b-P(GMA-g-PDMAEMA) neutral-cationic brush block copolymers that possess cationic poly(N,N-dimethylaminoethyl methacrylate) (PDMAEMA) brushes for DNA compaction, poly(ethylene oxide) (PEO) as a hydrophilic block, and poly(glycidyl methacrylate) (PGMA) as the backbone. The PEO-b-P(GMA-g-PDMAEMA) copolymers were synthesized through the combination of reversible addition-fragmentation transfer (RAFT) polymerization and postmodification. A photocleavable PEO-based macroRAFT agent was first synthesized; next, the PEO-b-PGMA block copolymer was prepared by RAFT polymerization of GMA; this was followed by a click reaction to introduce the RAFT initiators on the side chains of the PGMA block; then, RAFT polymerization of DMAEMA afforded the PEO-b-P(GMA-g-PDMAEMA) copolymer. The obtained neutral-cationic brush block copolymer could effectively complex plasmid DNA (pDNA) into nanoparticles at an N/P ratio (i.e., the number of nitrogen residues per DNA phosphate) of 4. Upon UV irradiation, pDNA could be released owing to cleavage of the pDNA-binding cationic PDMAEMA side chains as well as the nitrobenzyl ester linkages at the diblock junction point. In addition, in vitro gene transfection results demonstrated that the polyplexes could be effectively internalized by cells with good transfection efficiency, and the UV irradiation protocol could considerably enhance the efficiency of gene transfection. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Lateral phase separation of mixed polymer brushes on planar and spherical surfaces

    Science.gov (United States)

    van Lehn, Reid; Alexander-Katz, Alfredo

    2012-02-01

    A mixed polymer brush consists of two (or more) polymer species grafted to a surface at a high density, inducing the polymers to highly stretch to maximize favorable solvent interactions while minimizing polymer overlap. The enthalpic and entropic interactions between the different polymers give rise to lateral phase behavior on the surface. Understanding this phase separation behavior is interesting for applications in nanotemplating and controlled protein adsorption. In this work, we present a novel theoretical model to quickly predict lateral phase separated morphologies of mixed polymer brushes on planar, cylindrical and spherical surfaces. The model combines a Flory-Huggins model for enthalpic interactions between the polymer components with an Alexander-de Gennes model for the entropy of the brush layers. When there is a length difference between the polymer components, these two interactions along with the conformational entropy of the system lead to a range of morphologies including stripes, dimples, mixing, and complete phase separation. The computational efficiency of this model allows for phase diagrams to be generated with great accuracy. The results of our model thus allow for the fast prediction of lateral morphologies on different geometries.

  15. Polymer brushes infiltrated by nanoparticles and applications to the nuclear pore complex

    Science.gov (United States)

    Opferman, Michael G.

    Systems of grafted polymers in the presence of additives are useful in a variety of contexts including industrial applications, solar cells, organic electronics, drug delivery, and nucleocytoplasmic transport. In this thesis, we will consider the morphologies that polymer brushes attain when exposed to a solution of additives (which we generically term "nanoparticles"), particularly when those nanparticles interact attractively with the polymers. We find that nanoparticles of this type can have a dramatic effect on the height of the polymer chains above the grafting surface, and they can induce highly non-uniform morphologies, including ones in which a dense layer of nanoparticles and monomers forms near the grafting surface. We consider especially the relevance of the system to several experiments performed on biopolymers in the nuclear pore complex when they interact attractively with transport factors that regulate nucleocytoplasmic transport. We find that, although these experiments appear to give inconsistent results, the inconsistencies can be reconciled through two simple models: the Alexander-de Gennes polymer brush, and the Milner-Witten-Cates polymer brush. Our findings should contribute to the understanding of the nuclear pore complex in that experiments can be better understood in the context of their relevant control parameters.

  16. Polymer brush-functionalized chitosan hydrogels as antifouling implant coatings

    Czech Academy of Sciences Publication Activity Database

    Buzzacchera, I.; Vorobii, M.; Kostina, N. Yu.; de los Santos Pereira, Andres; Riedel, Tomáš; Bruns, M.; Ogieglo, W.; Möller, M.; Wilson, C. J.; Rodriguez-Emmenegger, C.

    2017-01-01

    Roč. 18, č. 6 (2017), s. 1983-1992 ISSN 1525-7797 R&D Projects: GA ČR(CZ) GBP205/12/G118 Institutional support: RVO:61389013 Keywords : chitosan * hemocompatible * polymer brushes Subject RIV: CE - Biochemistry OBOR OECD: Biochemistry and molecular biology Impact factor: 5.246, year: 2016

  17. Brush Polymer of Donor-Accepter Dyads via Adduct Formation between Lewis Base Polymer Donor and All Carbon Lewis Acid Acceptor

    Directory of Open Access Journals (Sweden)

    Yang Wang

    2017-09-01

    Full Text Available A synthetic method that taps into the facile Lewis base (LB→Lewis acid (LA adduct forming reaction between the semiconducting polymeric LB and all carbon LA C60 for the construction of covalently linked donor-acceptor dyads and brush polymer of dyads is reported. The polymeric LB is built on poly(3-hexylthiophene (P3HT macromers containing either an alkyl or vinyl imidazolium end group that can be readily converted into the N-heterocyclic carbene (NHC LB site, while the brush polymer architecture is conveniently constructed via radical polymerization of the macromer P3HT with the vinyl imidazolium chain end. Simply mixing of such donor polymeric LB with C60 rapidly creates linked P3HT-C60 dyads and brush polymer of dyads in which C60 is covalently linked to the NHC junction connecting the vinyl polymer main chain and the brush P3HT side chains. Thermal behaviors, electronic absorption and emission properties of the resulting P3HT-C60 dyads and brush polymer of dyads have been investigated. The results show that a change of the topology of the P3HT-C60 dyad from linear to brush architecture enhances the crystallinity and Tm of the P3HT domain and, along with other findings, they indicate that the brush polymer architecture of donor-acceptor domains provides a promising approach to improve performances of polymer-based solar cells.

  18. Diamond surface functionalization with biomimicry – Amine surface tether and thiol moiety for electrochemical sensors

    Energy Technology Data Exchange (ETDEWEB)

    Sund, James B., E-mail: jim@jamessund.com [Department of Electrical and Computer Engineering, Duke University, Durham, NC (United States); Causey, Corey P. [Departments of Chemistry and Biochemistry, Duke University, Durham, NC (United States); Wolter, Scott D. [Department of Physics, Elon University, Elon, NC 27244 (United States); Parker, Charles B., E-mail: charles.parker@duke.edu [Department of Electrical and Computer Engineering, Duke University, Durham, NC (United States); Stoner, Brian R. [Department of Electrical and Computer Engineering, Duke University, Durham, NC (United States); Research Triangle Institute (RTI) International, Research Triangle Park, NC (United States); Toone, Eric J. [Departments of Chemistry and Biochemistry, Duke University, Durham, NC (United States); Glass, Jeffrey T. [Department of Electrical and Computer Engineering, Duke University, Durham, NC (United States)

    2014-05-01

    Highlights: • Diamond surfaces were functionalized with organic molecules using a novel approach. • Used biomimicry to select a molecule to bind NO, similar to the human body. • Molecular orbital theory predicted the molecule-analyte oxidation behavior. • A thiol moiety was attached to an amine surface tether on the diamond surface. • XPS analysis verified each surface functionalization step. - Abstract: The surface of conducting diamond was functionalized with a terminal thiol group that is capable of binding and detecting nitrogen–oxygen species. The functionalization process employed multiple steps starting with doped diamond films grown by plasma enhanced chemical vapor deposition followed by hydrogen termination and photochemical attachment of a chemically protected amine alkene. The surface tether was deprotected to reveal the amine functionality, which enabled the tether to be extended with surface chemistry to add a terminal thiol moiety for electrochemical sensing applications. Each step of the process was validated using X-ray photoelectron spectroscopy analysis.

  19. Diamond surface functionalization with biomimicry – Amine surface tether and thiol moiety for electrochemical sensors

    International Nuclear Information System (INIS)

    Sund, James B.; Causey, Corey P.; Wolter, Scott D.; Parker, Charles B.; Stoner, Brian R.; Toone, Eric J.; Glass, Jeffrey T.

    2014-01-01

    Highlights: • Diamond surfaces were functionalized with organic molecules using a novel approach. • Used biomimicry to select a molecule to bind NO, similar to the human body. • Molecular orbital theory predicted the molecule-analyte oxidation behavior. • A thiol moiety was attached to an amine surface tether on the diamond surface. • XPS analysis verified each surface functionalization step. - Abstract: The surface of conducting diamond was functionalized with a terminal thiol group that is capable of binding and detecting nitrogen–oxygen species. The functionalization process employed multiple steps starting with doped diamond films grown by plasma enhanced chemical vapor deposition followed by hydrogen termination and photochemical attachment of a chemically protected amine alkene. The surface tether was deprotected to reveal the amine functionality, which enabled the tether to be extended with surface chemistry to add a terminal thiol moiety for electrochemical sensing applications. Each step of the process was validated using X-ray photoelectron spectroscopy analysis

  20. Numerical investigation of the contraction of neutral-charged diblock copolymer brushes in electric fields

    International Nuclear Information System (INIS)

    Chen, Yuwei; Li, Haiming; Zhu, Yuejin; Tong, Chaohui

    2016-01-01

    Using self-consistent field theory (SCFT), the contraction of neutral-charged A-B diblock copolymer brushes in electric fields generated by opposite surface charges on two parallel electrodes has been numerically investigated. The diblock copolymer chains were grafted with the free end of the neutral block to one electrode and immersed in a salt-free solution sandwiched between the two electrodes. The numerical results reveal that the charged monomers, A-B joint segment and the tail exhibit bimodal distributions under external electric fields, which are absent for homopolymer polyelectrolyte brushes. The dependences of the relative populations and peak positions of the two modes on various parameters such as block ratio, grafting density, chain length and strength of the applied electric field were systematically examined and the underlining mechanisms were elucidated. It was found in this study that, if the total amount of surface charges on the grafting electrode is no more than that of the counter-ions in the system, overall charge neutrality is generally maintained inside the brushes when including the contribution of surface charges on the grafting electrode. In such a case, the counter-ions expelled from the brushes are highly enriched in the immediate vicinity of the second electrode and an approximate charge balance between these expelled counter-ions and the opposite surface charges on the second electrode is achieved. (paper)

  1. Anti-glycosyl antibodies in lipid rafts of the enterocyte brush border: a possible host defense against pathogens

    DEFF Research Database (Denmark)

    Hansen, Gert Helge; Pedersen, Esben D K; Immerdal, Lissi

    2005-01-01

    a major part of the immunoglobulins at the lumenal surface of the gut. The antibodies were associated with lipid rafts at the brush border, and they frequently (52%) coclustered with the raft marker galectin 4. A lactose wash increased the susceptibility of the brush border toward lectin peanut agglutin...

  2. Technical and economical assessment on tethered wind-energy systems (TWES)

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, O.; Maekawa, S.

    1982-06-01

    The objective of the work reported was to establish the potential of tethered wind energy systems for energy conversion in the upper atmosphere. Of the concepts investigated, the Vertical Takeoff and Landing (VTOL) lift generation concept had the highest potential as compared to balloon, wind and hybrid concepts.

  3. Jejunal brush border microvillous alterations in Giardia muris-infected mice: role of T lymphocytes and interleukin-6.

    Science.gov (United States)

    Scott, K G; Logan, M R; Klammer, G M; Teoh, D A; Buret, A G

    2000-06-01

    Intestinal colonization with the protozoan Giardia causes diffuse brush border microvillous alterations and disaccharidase deficiencies, which in turn are responsible for intestinal malabsorption and maldigestion. The role of T cells and/or cytokines in the pathogenesis of Giardia-induced microvillous injury remains unclear. The aim of this study was to assess the role of T cells and interleukin-6 (IL-6) in the brush border pathophysiology of acute murine giardiasis in vivo. Athymic nude (nu(-)/nu(-)) CD-1 mice and isogenic immunocompetent (nu(+)/nu(+)) CD-1 mice (4 weeks old) received an axenic Giardia muris trophozoite inoculum or vehicle (control) via orogastric gavage. Weight gain and food intake were assessed daily. On day 6, segments of jejunum were assessed for parasite load, brush border ultrastructure, IL-6 content, maltase and sucrase activities, villus-crypt architecture, and intraepithelial lymphocyte (IEL) infiltration. Despite similar parasitic loads on day 6, infected immunocompetent animals, but not infected nude mice, showed a diffuse loss of brush border microvillous surface area, which was correlated with a significant reduction in maltase and sucrase activities and a decrease in jejunal IL-6 concentration. In both athymic control and infected mice, jejunal brush border surface area and disaccharidases were high, but levels of tissue IL-6 were low and comparable to the concentration measured in immunocompetent infected animals. In both immunocompetent and nude mice, infection caused a small but significant increase in the numbers of IELs. These findings suggest that the enterocyte brush border injury and malfunction seen in giardiasis is, at least in part, mediated by thymus-derived T lymphocytes and that suppressed jejunal IL-6 does not necessarily accompany microvillous shortening.

  4. Investigating the dominant corrections to the strong-stretching theory for dry polymeric brushes.

    Science.gov (United States)

    Matsen, M W

    2004-07-22

    The accuracy of strong-stretching theory (SST) is examined against a detailed comparison to self-consistent field theory (SCFT) on dry polymeric brushes with thicknesses of up to approximately 17 times the natural chain extension. The comparison provides the strongest evidence to date that SST represents the exact thick-brush limit of SCFT. More importantly, it allows us to assess the effectiveness of proposed finite-stretching corrections to SST. Including the entropy of the free ends is shown to rectify the most severe inaccuracies in SST. The proximal layer proposed by Likhtman and Semenov provides another significant improvement, and we identify one further effect of similar importance for which there is not yet an accurate treatment. Furthermore, our study provides a valuable means of rejecting mistaken refinements to SST, and indeed one such example is revealed. A proper treatment of finite-stretching corrections is vital to a wide range of phenomena that depend on a small excess free energy, such as autophobic dewetting and the interaction between opposing brushes.

  5. Diamond surface functionalization with biomimicry - Amine surface tether and thiol moiety for electrochemical sensors

    Science.gov (United States)

    Sund, James B.; Causey, Corey P.; Wolter, Scott D.; Parker, Charles B.; Stoner, Brian R.; Toone, Eric J.; Glass, Jeffrey T.

    2014-05-01

    The surface of conducting diamond was functionalized with a terminal thiol group that is capable of binding and detecting nitrogen-oxygen species. The functionalization process employed multiple steps starting with doped diamond films grown by plasma enhanced chemical vapor deposition followed by hydrogen termination and photochemical attachment of a chemically protected amine alkene. The surface tether was deprotected to reveal the amine functionality, which enabled the tether to be extended with surface chemistry to add a terminal thiol moiety for electrochemical sensing applications. Each step of the process was validated using X-ray photoelectron spectroscopy analysis.

  6. Sulfobetaine-based polymer brushes in marine environment: Is there an effect of the polymerizable group on the antifouling performance?

    NARCIS (Netherlands)

    Quintana, R.; Janczewski, D.; Vasantha, V.A.; Jana, S.; Lee, S.S.C.; Parra-Velandia, F.J.; Guo, S.; Parthiban, A.; Teo, S.L-M.; Vancso, Gyula J.

    2014-01-01

    Three different zwitterionic polymer brush coatings for marine biofouling control were prepared bysurface-initiated atom transfer radical polymerization (ATRP) of sulfobetaine-based monomers includingmethacrylamide (SBMAm), vinylbenzene (SBVB) and vinylimidazolium (SBVI). None of these brush

  7. Electric double layer electrostatics of pH-responsive spherical polyelectrolyte brushes in the decoupled regime.

    Science.gov (United States)

    Li, Hao; Chen, Guang; Das, Siddhartha

    2016-11-01

    Understanding the behavior and properties of spherical polyelectrolyte brushes (SPEBs), which are polyelectrolyte brushes grafted to a spherical core, is fundamental to many applications in biomedical, chemical and petroleum engineering as well as in pharmaceutics. In this paper, we study the pH-responsive electrostatics of such SPEBs in the decoupled regime. In the first part of the paper, we derive the scaling conditions in terms of the grafting density of the PEs on the spherical core that ensure that the analysis can be performed in the decoupled regime. In such a regime the elastic and the excluded volume effects of polyelectrolyte brushes (PEBs) can be decoupled from the electrostatic effects associated with the PE charge and the induced EDL. As a consequence the PE brush height, assumed to be dictated by the balance of the elastic and excluded volume effects, can be independent of the electrostatic effects. In the second part, we quantify the pH-responsive electrostatics of the SPEBs - we pinpoint that the radial monomer distribution for a given brush molecule exhibit a non-unique cubic distribution that decays away from the spherical core. Such a monomer distribution ensures that the hydrogen ion concentration is appropriately accounted for in the description of the SPEB thermodynamics. We anticipate that the present analysis, which provides possibly one of the first models for probing the electrostatics of pH-responsive SPEBs in a thermodynamically-consistent framework, will be vital for understanding the behavior of a large number of entities ranging from PE-coated NPs and stealth liposomes to biomolecules like bacteria and viruses. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Brush seal leakage performance with gaseous working fluids at static and low rotor speed conditions

    Science.gov (United States)

    Carlile, Julie A.; Hendricks, Robert C.; Yoder, Dennis A.

    1992-01-01

    The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was studied. The leakage results included for air, helium, and carbon dioxide at several bristle/rotor interferences. Also, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were studied. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in.), a fence height of 0.0635 cm (0.025 in.), and 1800 bristles/cm circumference (4500 bristles/in. circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison to the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approximately the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times. The air and carbon dioxide data were successfully correlated using corresponding state theory. However, the helium data followed a different curve than the air and carbon dioxide data.

  9. Self-Assembly of Narrowly Dispersed Brush Diblock Copolymers with Domain Spacing more than 100 nm

    Science.gov (United States)

    Gu, Weiyin; Sveinbjornsson, Benjamin; Hong, Sung Woo; Grubbs, Robert; Russell, Thomas

    2012-02-01

    Self-assembled structures of high molecular weight (MW), narrow molecular weight distribution brush block copolymers containing polylactic acid (PLA) and polystyrene (PS) side chains with similar MWs were studied in both the melt and thin films. The polynorbornene-backbone-based brush diblock copolymers containing approximately equal volume fractions of each block self-assembled into highly ordered lamellae with domain spacing over 100 nm, as revealed by SAXS, GISAXS and AFM. The domain size increased approximately linearly with backbone length, which indicated an extended conformation of the backbone in the ordered state. The length of side chains also played a significant role in terms of controlling the domain size. As the degree of polymerization (DP) increased, the symmetric brush diblock copolymers with longer side chains tended to form larger lamellar microdomains in comparison to those that have the same DP but shorter side chains.

  10. Phase coupling of a circadian neuropeptide with rest/activity rhythms detected using a membrane-tethered spider toxin.

    Directory of Open Access Journals (Sweden)

    Ying Wu

    2008-11-01

    Full Text Available Drosophila clock neurons are self-sustaining cellular oscillators that rely on negative transcriptional feedback to keep circadian time. Proper regulation of organismal rhythms of physiology and behavior requires coordination of the oscillations of individual clock neurons within the circadian control network. Over the last decade, it has become clear that a key mechanism for intercellular communication in the circadian network is signaling between a subset of clock neurons that secrete the neuropeptide pigment dispersing factor (PDF and clock neurons that possess its G protein-coupled receptor (PDFR. Furthermore, the specific hypothesis has been proposed that PDF-secreting clock neurons entrain the phase of organismal rhythms, and the cellular oscillations of other clock neurons, via the temporal patterning of secreted PDF signals. In order to test this hypothesis, we have devised a novel technique for altering the phase relationship between circadian transcriptional feedback oscillation and PDF secretion by using an ion channel-directed spider toxin to modify voltage-gated Na(+ channel inactivation in vivo. This technique relies on the previously reported "tethered-toxin" technology for cell-autonomous modulation of ionic conductances via heterologous expression of subtype-specific peptide ion channel toxins as chimeric fusion proteins tethered to the plasma membrane with a glycosylphosphatidylinositol (GPI anchor. We demonstrate for the first time, to our knowledge, the utility of the tethered-toxin technology in a transgenic animal, validating four different tethered spider toxin ion channel modifiers for use in Drosophila. Focusing on one of these toxins, we show that GPI-tethered Australian funnel-web spider toxin delta-ACTX-Hv1a inhibits Drosophila para voltage-gated Na(+ channel inactivation when coexpressed in Xenopus oocytes. Transgenic expression of membrane-tethered delta-ACTX-Hv1a in vivo in the PDF-secreting subset of clock neurons

  11. Suppressing Pseudomonas aeruginosa adhesion via non-fouling polymer brushes

    Czech Academy of Sciences Publication Activity Database

    Rodriguez-Emmenegger, Cesar; Decker, A.; Surman, František; Preuss, C. M.; Sedláková, Zdeňka; Zydziak, N.; Barner-Kowollik, C.; Schwartz, T.; Barner, L.

    2014-01-01

    Roč. 4, č. 110 (2014), s. 64781-64790 ISSN 2046-2069 R&D Projects: GA MŠk(CZ) ED1.1.00/02.0109; GA ČR GAP106/12/1451 Institutional support: RVO:61389013 Keywords : polymer brushes * tissue engineering * biology Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.840, year: 2014

  12. Computer Programs for Calculating and Plotting the Stability Characteristics of a Balloon Tethered in a Wind

    Science.gov (United States)

    Bennett, R. M.; Bland, S. R.; Redd, L. T.

    1973-01-01

    Computer programs for calculating the stability characteristics of a balloon tethered in a steady wind are presented. Equilibrium conditions, characteristic roots, and modal ratios are calculated for a range of discrete values of velocity for a fixed tether-line length. Separate programs are used: (1) to calculate longitudinal stability characteristics, (2) to calculate lateral stability characteristics, (3) to plot the characteristic roots versus velocity, (4) to plot the characteristic roots in root-locus form, (5) to plot the longitudinal modes of motion, and (6) to plot the lateral modes for motion. The basic equations, program listings, and the input and output data for sample cases are presented, with a brief discussion of the overall operation and limitations. The programs are based on a linearized, stability-derivative type of analysis, including balloon aerodynamics, apparent mass, buoyancy effects, and static forces which result from the tether line.

  13. Use of Tethered Enzymes as a Platform Technology for Rapid Analyte Detection.

    Directory of Open Access Journals (Sweden)

    Roy Cohen

    Full Text Available Rapid diagnosis for time-sensitive illnesses such as stroke, cardiac arrest, and septic shock is essential for successful treatment. Much attention has therefore focused on new strategies for rapid and objective diagnosis, such as Point-of-Care Tests (PoCT for blood biomarkers. Here we use a biomimicry-based approach to demonstrate a new diagnostic platform, based on enzymes tethered to nanoparticles (NPs. As proof of principle, we use oriented immobilization of pyruvate kinase (PK and luciferase (Luc on silica NPs to achieve rapid and sensitive detection of neuron-specific enolase (NSE, a clinically relevant biomarker for multiple diseases ranging from acute brain injuries to lung cancer. We hypothesize that an approach capitalizing on the speed and catalytic nature of enzymatic reactions would enable fast and sensitive biomarker detection, suitable for PoCT devices.We performed in-vitro, animal model, and human subject studies. First, the efficiency of coupled enzyme activities when tethered to NPs versus when in solution was tested, demonstrating a highly sensitive and rapid detection of physiological and pathological concentrations of NSE. Next, in rat stroke models the enzyme-based assay was able in minutes to show a statistically significant increase in NSE levels in samples taken 1 hour before and 0, 1, 3 and 6 hours after occlusion of the distal middle cerebral artery. Finally, using the tethered enzyme assay for detection of NSE in samples from 20 geriatric human patients, we show that our data match well (r = 0.815 with the current gold standard for biomarker detection, ELISA-with a major difference being that we achieve detection in 10 minutes as opposed to the several hours required for traditional ELISA.Oriented enzyme immobilization conferred more efficient coupled activity, and thus higher assay sensitivity, than non-tethered enzymes. Together, our findings provide proof of concept for using oriented immobilization of active

  14. Spinal column shortening for tethered cord syndrome associated with myelomeningocele, lumbosacral lipoma, and lipomyelomeningocele in children and young adults.

    Science.gov (United States)

    Aldave, Guillermo; Hansen, Daniel; Hwang, Steven W; Moreno, Amee; Briceño, Valentina; Jea, Andrew

    2017-06-01

    OBJECTIVE Tethered cord syndrome is the clinical manifestation of an abnormal stretch on the spinal cord, presumably causing mechanical injury, a compromised blood supply, and altered spinal cord metabolism. Tethered cord release is the standard treatment for tethered cord syndrome. However, direct untethering of the spinal cord carries potential risks, such as new neurological deficits from spinal cord injury, a CSF leak from opening the dura, and retethering of the spinal cord from normal scar formation after surgery. To avoid these risks, the authors applied spinal column shortening to children and transitional adults with primary and secondary tethered cord syndrome and report treatment outcomes. The authors' aim with this study was to determine the safety and efficacy of spinal column shortening for tethered cord syndrome by analyzing their experience with this surgical technique. METHODS The authors retrospectively reviewed the demographic and procedural data of children and young adults who had undergone spinal column shortening for primary or secondary tethered cord syndrome. RESULTS Seven patients with tethered cord syndrome caused by myelomeningocele, lipomyelomeningocele, and transitional spinal lipoma were treated with spinal column shortening. One patient with less than 24 months of follow-up was excluded from further analysis. There were 3 males and 4 females; the average age at the time was surgery was 16 years (range 8-30 years). Clinical presentations for our patients included pain (in 5 patients), weakness (in 4 patients), and bowel/bladder dysfunction (in 4 patients). Spinal column osteotomy was most commonly performed at the L-1 level, with fusion between T-12 and L-2 using a pedicle screw-rod construct. Pedicle subtraction osteotomy was performed in 6 patients, and vertebral column resection was performed in 1 patient. The average follow-up period was 31 months (range 26-37 months). Computed tomography-based radiographic outcomes showed solid

  15. Endogenous opioids are involved in abnormal stereotyped behaviour of tethered sows

    NARCIS (Netherlands)

    Cronin, G.M.; Wiepkema, P.R.; Ree, van J.M.

    1985-01-01

    Tethered sows continuously performed stereotypies during a substantial part of the day time. A single subcutaneous injection with naloxone significantly decreased the profound stereotypies, while explorative behaviours of pigs were not affected by naloxone. In addition a long-term effect of naloxone

  16. Endogenous opioids are involved in abnormal stereotyped behaviours of tethered sows

    NARCIS (Netherlands)

    Cronin, G.M.; Wiepkema, P.R.; Ree, J.M. van

    1985-01-01

    Tethered sows continuously performed stereotypies during a substantial part of the day time. A single subcutaneous injection with naloxone significantly decreased the profound stereotypies, while explorative behaviours of pigs were not affected by naloxone. In addition a long-term effect of naloxone

  17. TETHERED BALLOON MEASUREMENTS OF BIOGENIC VOCS IN THE ATMOSPHERIC BOUNDARY LAYER

    Science.gov (United States)

    Measurements of biogenic volatile organic compounds (BVOCs) have been made on a tethered balloon platform in eleven field deployments between 1985 and 1996. A series of balloon sampling packages have been developed for these campaigns and they have been used to describe boundary ...

  18. Brush Day & Night Phase III to Phase IV: ensuring that good oral health habits are sustainable.

    Science.gov (United States)

    Melo, Paulo; Fine, Charlotte; Malone, Sinead; Horn, Virginie

    2018-05-01

    Over the past 10 years, the FDI-Unilever Brush Day & Night partnership has significantly influenced the life of children worldwide through the implementation of school programmes for oral health education and prevention. This article reports the key facts and outcomes of Phase III of the partnership, and announces the launch of Phase IV. During Phase III, the expert advisors of the Brush Day & Night partnership conducted a longitudinal study to evaluate the impact of the '21 Day' programme in almost 8,000 children in 10 countries. Analysis revealed the effectiveness of the 21 Day programme in sustainably educating children to brush their teeth twice a day, with the greatest impact observed in children aged 7-9 years. With the launch of Phase IV, the Brush Day & Night partnership will continue to deliver its oral health school programme for 7-9 year-old children with a strengthened methodology, including randomized sampling and control groups. The scope of the evaluation will be broadened to include oral health-related quality of life indicators, and monitoring of the oral health knowledge of children's parents/carers. © 2018 FDI World Dental Federation.

  19. Analytical investigation of the dynamics of tethered constellations in Earth orbit, phase 2

    Science.gov (United States)

    Lorenzini, E. C.; Arnold, D. A.; Cosmo, M.; Grossi, M. D.

    1986-10-01

    The following topics related to the dynamics of the 4-mass tethered system are addressed: (1) the development of damping algorithms for damping the out-of-plane libration of the system and the interaction of the out-of-plane control with the other degrees of freedom; and (2) the development of environmental models to be added to the dynamics simulation computer code. The environmental models are specifically a new drag routine based on the Jacchia's 1977 model, a J(2) model and an accurate thermal model of the wire. Regarding topic (1) a survey of various out-of-plane libration control laws was carried out. Consequently a yo-yo control law with amplitude of the tether length variation proportional to the amplitude of the out-of-game libration has been selected. This control law provides good damping when applied to a (theoretical) two-dimensional system. In the actual 3-dimensional 4-mass tethered system, however, energy is transferred to the least damped degrees of freedom (the out-of-plane lateral deflections are still undamped in the present simulations) in such a way as to decrease the effectiveness of the algorithm for out-of-plane libration control. The addition of damping algorithms for the out-of-plane lateral deflections is therefore necessary.

  20. Improving protein resistance of {alpha}-Al{sub 2}O{sub 3} membranes by modification with POEGMA brushes

    Energy Technology Data Exchange (ETDEWEB)

    He Huating [State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemistry and Chemical Engineering, Nanjing University of Technology, Nanjing 210009 (China); Jing Wenheng, E-mail: jingwenheng@yahoo.com.cn [State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemistry and Chemical Engineering, Nanjing University of Technology, Nanjing 210009 (China); Xing Weihong; Fan Yiqun [State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemistry and Chemical Engineering, Nanjing University of Technology, Nanjing 210009 (China)

    2011-11-15

    A kind of protein-resistant ceramic membrane is prepared by grafting poly(oligo (ethylene glycol) methyl ether methacrylate) (POEGMA) brushes onto the surfaces and pore walls of {alpha}-Al{sub 2}O{sub 3} membrane (AM) by surface-initiated atom-transfer radical polymerization (SI-ATRP). Contact-angle, Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA) and field-emission scanning electron microscopy (FESEM) were measured to confirm that the surfaces and pore walls of the ceramic porous membranes have been modified by the brushes with this method successfully. The protein interaction behavior with the POEGMA modified membranes (AM-POEGMA) was studied by the model protein of bovine serum albumin (BSA). A protein-resistant mechanism of AM-POEGMA was proposed to describe an interesting phenomenon discovered in the filtration experiment, in which the initial flux filtrating BSA solution is higher than the pure water flux. The fouling of AM-POEGMA was easier to remove than AM for the action of POEGMA brushes, indicated that the ceramic porous membranes modified with POEGMA brushes exhibit excellent protein resistance.

  1. Brush competition retards early stand development of planted ponderosa pine: update on a 24-year study

    Science.gov (United States)

    William W. Oliver

    1990-01-01

    Growth of ponderosa pine (Pinus ponderosa) was monitored for 24 years after planting at five different square spacings (6, 9. 12, 15, and 18 ft) in the presence or absence of competing brush on the westside Sierra Nevada. Spacing strongly influenced both mean dbh and basal area/ac. In plots maintained free of brush, diameters ranged from 5.1 in. at the 6-ft spacing to...

  2. Compact, planar, translational piezoelectric bimorph actuator with Archimedes’ spiral actuating tethers

    International Nuclear Information System (INIS)

    Yang, Chenye; Liu, Sanwei; Livermore, Carol; Xie, Xin

    2016-01-01

    The design, analytical modelling, finite element analysis (FEA), and experimental characterization of a microelectromechanical system (MEMS) out-of-plane (vertical) translational piezoelectric lead–zirconate–titanate (PZT) bimorph actuator supported on Archimedes’ spiral tethers are presented. Three types of bimorph actuators with different electrode patterns (with spiral tethers half actuated, fully actuated with uniform polarity, or fully actuated with reversed polarity) are designed and modelled. The two actuators with the highest predicted performance (half actuated and fully actuated with uniform polarity) are implemented and characterized. Both designs are fabricated by commercial processes and are compatible with integration into more complex MEMS systems. Analytical modelling and FEA are used to analyze and predict the actuators’ displacements and blocking forces. Experimental measurements of the deflections and blocking forces of actuators with full uniform actuation and half actuation validate the design. At an applied voltage of 110 V, the out-of-plane deflections of the actuators with half actuation and full uniform actuation are measured at about 17 µ m and 29 µ m respectively, in good agreement with analytical predictions of 17.3 µ m and 34.2 µ m and FEA predictions of 17.1 µ m and 25.8 µ m. The blocking force for devices with half-actuated tethers is predicted to be 12 mN (analytical) and 10 mN (FEA), close to the experimental value of 9 mN. The blocking force for devices with full uniform actuation is predicted to be 23 mN (analytical) and 17 mN (FEA), as compared with 15 mN in experiments. (paper)

  3. Polymer brushes: a controllable system with adjustable glass transition temperature of fragile glass formers.

    Science.gov (United States)

    Xie, Shi-Jie; Qian, Hu-Jun; Lu, Zhong-Yuan

    2014-01-28

    We present results of molecular dynamics simulations for coarse-grained polymer brushes in a wide temperature range to investigate the factors that affect the glass transition in these systems. We focus on the influences of free surface, polymer-substrate interaction strength, grafting density, and chain length not only on the change of glass transition temperature Tg, but also the fragility D of the glass former. It is found that the confinement can enhance the dependence of the Tg on the cooling rate as compared to the bulk melt. Our layer-resolved analysis demonstrates that it is possible to control the glass transition temperature Tg of polymer brushes by tuning the polymer-substrate interaction strength, the grafting density, and the chain length. Moreover, we find quantitative differences in the influence range of the substrate and the free surface on the density and dynamics. This stresses the importance of long range cooperative motion in glass formers near the glass transition temperature. Furthermore, the string-like cooperative motion analysis demonstrates that there exists a close relation among glass transition temperature Tg, fragility D, and string length ⟨S⟩. The polymer brushes that possess larger string length ⟨S⟩ tend to have relatively higher Tg and smaller D. Our results suggest that confining a fragile glass former through forming polymer brushes changes not only the glass transition temperature Tg, but also the very nature of relaxation process.

  4. Cylindrical polymer brushes with dendritic side chains by iterative anionic reactions

    KAUST Repository

    Zhang, Hefeng; Qu, Chengke; He, Junpo

    2015-01-01

    We report in this paper an easy method for the synthesis of cylindrical polymer brushes with dendritic side chains through anionic reaction. The synthesis is accomplished by iteratively grafting a living block copolymer, polyisoprene-. b

  5. Salt-Induced Control of the Grafting Density in Poly(ethylene glycol) Brush Layers by a Grafting-to Approach

    DEFF Research Database (Denmark)

    Ortiz, Roberto; Olsen, Stefan; Thormann, Esben

    2018-01-01

    In this work, a method to obtain control of the grafting density during the formation of polymer brush layers by the grafting-to method of thiolated poly(ethylene glycol) onto gold is presented. The grafting density of the polymer chains was adjusted by adding Na2SO4 in concentrations between 0.......2 and 0.9 M to the aqueous polymer solution during the grafting process. The obtained grafting densities ranged from 0.26 to 1.60 chains nm-2, as determined by surface plasmon resonance. The kinetics of the grafting process were studied in situ by a quartz crystal microbalance with dissipation......, and a mushroom to brush conformational transition was observed when the polymer was grafted in the presence of Na2SO4. The transition from mushroom to brush was only observed for long periods of grafting, highlighting the importance of time to obtain high grafting densities. Finally, the prepared brush layer...

  6. Wetting phase diagrams of polyacid brush with a triple point.

    NARCIS (Netherlands)

    Mercurieva, A.A.; Iakovlev, P.A.; Zhulina, E.B.; Birshtein, T.M.; Leermakers, F.A.M.

    2006-01-01

    The (pre)wetting behavior of an annealed polyelectrolyte (PE) brush by an electrolyte solution that is strongly segregated from an apolar phase is analyzed. In this complex interface, there are interactions on various length scales. There are short-range interactions with the (uncharged) surface,

  7. Stable Protein-Repellent Zwitterionic Polymer Brushes Grafted from Silicon Nitride

    NARCIS (Netherlands)

    Nguyen, A.T.; Baggerman, J.; Paulusse, J.M.J.; Rijn, van C.J.M.; Zuilhof, H.

    2011-01-01

    Zwitterionic poly(sulfobetaine acrylamide) (SBMAA) brushes were grafted from silicon-rich silicon nitride (SixN4, x > 3) surfaces by atom transfer radical polymerization (ATRP) and studied in protein adsorption experiments. To this aim ATRP initiators were immobilized onto SixN4 through stable

  8. The secret life of tethers: the role of tethering factors in SNARE complex regulation

    Directory of Open Access Journals (Sweden)

    Michelle L Dubuke

    2016-05-01

    Full Text Available Trafficking in eukaryotic cells is a tightly regulated process to ensure correct cargo delivery to the proper destination organelle or plasma membrane. In this review, we focus on how the vesicle fusion machinery, the SNARE complex, is regulated by the interplay of the multisubunit tethering complexes (MTC with the SNAREs and Sec1/Munc18 (SM proteins. Although these factors are used in different stages of membrane trafficking, e.g. Golgi to plasma membrane transport vs vacuolar fusion, and in a variety of diverse eukaryotic cell types, many commonalities between their functions are being revealed. We explore the various protein-protein interactions and findings from functional reconstitution studies in order to highlight both their common features and the differences in their modes of regulation. These studies serve as a starting point for mechanistic explorations in other systems.

  9. Extreme delta brush evolving into status epilepticus in a patient with anti-NMDA encephalitis

    Directory of Open Access Journals (Sweden)

    Aline Herlopian, MD

    2017-01-01

    Full Text Available Extreme delta brush (EDB is an EEG pattern unique to anti-NMDA encephalitis. It is correlated with seizures and status epilepticus in patients who have a prolonged course of illness. The etiology of the underlying association between EDB and seizures is not understood. We present a patient with anti-NMDA encephalitis who developed status epilepticus evolving from the high frequency activity of the extreme delta brush. This case demonstrates that EDB is not only a marker for a greater propensity for seizures but also directly implicated in seizure generation.

  10. [Relationship between first molar caries and eating and tooth brushing habits in elementary school children].

    Science.gov (United States)

    Fujiwara, Aiko; Takeda, Fumi

    2010-11-01

    The aim of the present study was to elucidate the relationship between eating and tooth brushing habits in the second grade of elementary school with first molar caries in the third to sixth grades. Subjects were 130 students at one elementary school in the Tokai region who were in the second grade in 2002, for which eating and tooth-brushing habits were ascertained by a self-administered questionnaire survey. A follow-up survey was conducted based on the 2002 to 2006 school dental examination record and analyses were performed on data from 104 students without first molar dental caries in the second grade. The incidences of first molar caries in the third grade were higher among students who ate cookies at least once daily or every 2 to 3 days, compared with those who ate cookies once a week or not at all in the second grade. Incidences were also higher among those whose daily frequency of tooth brushing was once or sometimes compared with twice or three times or more. Furthermore, the incidences of first molar caries in the fourth, fifth and sixth grades were higher among students who ate candy at least once daily or every 2 to 3 days, compared with those who ate candy once a week or not at all in the second grade. The intake frequency of cookies was related to the first molar caries in the third grade, and of candy for that in the fourth to sixth grades. Moreover, first molar caries in the third grade were also related to the daily frequency of second-grade tooth brushing. These findings suggest the importance of measures encouraging lower-grade elementary students to establish and maintain habits of tooth brushing and of limiting consumption of sweets, such as cookies and candy, in order to prevent caries in their permanent teeth during elementary school.

  11. Rangeland Brush Estimation Toolbox (RaBET): An Approach for Evaluating Brush Management Conservation Efforts in Western Grazing Lands

    Science.gov (United States)

    Holifield Collins, C.; Kautz, M. A.; Skirvin, S. M.; Metz, L. J.

    2016-12-01

    There are over 180 million hectares of rangelands and grazed forests in the central and western United States. Due to the loss of perennial grasses and subsequent increased runoff and erosion that can degrade the system, woody cover species cannot be allowed to proliferate unchecked. The USDA-Natural Resources Conservation Service (NRCS) has allocated extensive resources to employ brush management (removal) as a conservation practice to control woody species encroachment. The Rangeland-Conservation Effects Assessment Project (CEAP) has been tasked with determining how effective the practice has been, however their land managers lack a cost-effective means to conduct these assessments at the necessary scale. An ArcGIS toolbox for generating large-scale, Landsat-based, spatial maps of woody cover on grazing lands in the western United States was developed through a collaboration with NRCS Rangeland-CEAP. The toolbox contains two main components of operation, image generation and temporal analysis, and utilizes simple interfaces requiring minimum user inputs. The image generation tool utilizes geographically specific algorithms developed from combining moderate-resolution (30-m) Landsat imagery and high-resolution (1-m) National Agricultural Imagery Program (NAIP) aerial photography to produce the woody cover scenes at the Major Land Resource (MLRA) scale. The temporal analysis tool can be used on these scenes to assess treatment effectiveness and monitor woody cover reemergence. RaBET provides rangeland managers an operational, inexpensive decision support tool to aid in the application of brush removal treatments and assessing their effectiveness.

  12. Tethered Lubricants for Small Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lynden A. Archer

    2006-01-09

    The objective of this research project is two-fold. First, to fundamentally understand friction and relaxation dynamics of polymer chains near surfaces; and second, to develop novel self-lubricated substrates suitable for MEMS devices. During the three-year performance period of this study the PI and his students have shown using theory and experiments that systematic introduction of disorder into tethered lubricant coatings (e.g. by using self-assembled monolayer (SAM) mixtures or SAMs with nonlinear, branched architectures) can be used to significantly reduce the friction coefficient of a surface. They have also developed a simple procedure based on dielectric spectroscopy for quantifying the effect of surface disorder on molecular relaxation in lubricant coatings. Details of research accomplishments in each area of the project are described in the body of the report.

  13. Theseus: tethered distributed robotics (TDR)

    Science.gov (United States)

    Digney, Bruce L.; Penzes, Steven G.

    2003-09-01

    The Defence Research and Development Canada's (DRDC) Autonomous Intelligent System's program conducts research to increase the independence and effectiveness of military vehicles and systems. DRDC-Suffield's Autonomous Land Systems (ALS) is creating new concept vehicles and autonomous control systems for use in outdoor areas, urban streets, urban interiors and urban subspaces. This paper will first give an overview of the ALS program and then give a specific description of the work being done for mobility in urban subspaces. Discussed will be the Theseus: Thethered Distributed Robotics (TDR) system, which will not only manage an unavoidable tether but exploit it for mobility and navigation. Also discussed will be the prototype robot called the Hedgehog, which uses conformal 3D mobility in ducts, sewer pipes, collapsed rubble voids and chimneys.

  14. Nonadhesive, silica nanoparticles-based brush-coated contact lens cases--compromising between ease of cleaning and microbial transmission to contact lenses.

    Science.gov (United States)

    Qu, Wenwen; Hooymans, Johanna M M; Qiu, Jun; de-Bont, Nik; Gelling, Onko-Jan; van der Mei, Henny C; Busscher, Henk J

    2013-05-01

    Surface properties of lens cases are determinant for their cleanability and for microbial transmission from lens cases to contact lenses (CLs). PEG-polymer-brush-coatings are known to decrease microbial adhesion more than other surface-coatings. Here, we applied a robust, silica nanoparticles-based brush-coating to polypropylene cases to evaluate their ease of cleaning and probability of bacterial transmission to CLs. Adhesion forces of nine bacterial strains (Pseudomonas, Staphylococci, and Serratia) to rigid CLs, polypropylene, and silica nanoparticles-based brush-coated polypropylene were measured using atomic-force-microscopy and subjected to Weibull analyses to yield bacterial transmission probabilities. Biofilms of each strain were grown in coated and uncoated cases and rinsed with a NaCl or antimicrobial lens care solution. Residual, viable organisms were quantified. Bacterial adhesion forces of all strains were significantly, up to tenfold smaller on brush-coated than on uncoated polypropylene. This yielded, higher transmission probabilities to a CL, but mild-rinsing yielded 10-100 fold higher removal of bacteria from brush-coated than from polypropylene cases. Moreover, due to weak adhesion forces, bacteria on brush-coated cases were two-to-three fold more susceptible to an antimicrobial lens care solution than on polypropylene cases. Therewith, the design of lens case surfaces is a compromise between ease of cleaning and transmission probability to CLs. Copyright © 2013 Wiley Periodicals, Inc.

  15. Cholesterol tethered bioresponsive polycation as a candidate for gene delivery

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Ying [Second Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310009 (China); Wang Youxiang, E-mail: yx_wang@zju.edu.cn [Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Key Laboratory of Macromolecular Synthesis and Functionalization, Ministry of Education, Zhejiang University, Hangzhou 310027 (China); Hu Qiaoling; Shen Jiacong [Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Key Laboratory of Macromolecular Synthesis and Functionalization, Ministry of Education, Zhejiang University, Hangzhou 310027 (China)

    2009-04-30

    The efficient unpacking of viral protein shell gave the inspiration for the synthesized vectors. In this research, novel cholesterol tethered bioresponsive polyethylenimine (PEI) was specially designed via disulfide-containing cross-linker. The cholesterol lipid had proved to increase the permeability of gene vector through cell membrane. The acid-base titration indicated that the synthesized polycation possessed efficient proton sponge effect, which was suggested to increase endosomal release of pDNA complexes into the cytoplasm. The cholesterol tethered polycation could effectively induce DNA condensation and form spherical particles with diameter about 200 nm at N/P ratio of 10. At glutathione concentration of 3 mM, the polyplexes were unpacked due to the bioresponsive cleavage of the disulfide bonds. The in-vitro experiment indicated that the polyplexes showed efficient transfection efficiency to HEK293T cells. All the results indicated that the bioresponsive polycation could be served as an effective trigger to control the release of DNA at the intracellular environment. The novel bioresponsive polycation might have great potential in non-viral gene delivery research and application.

  16. Stable Protein-Repellent Zwitterionic Polymer Brushes Grafted from Silicon Nitride

    NARCIS (Netherlands)

    Nguyen, Ai T.; Baggerman, Jacob; Paulusse, Jos Marie Johannes; van Rijn, Cees J.M.; Zuilhof, Han

    2011-01-01

    Zwitterionic poly(sulfobetaine acrylamide) (SBMAA) brushes were grafted from silicon-rich silicon nitride (SixN4, x > 3) surfaces by atom transfer radical polymerization (ATRP) and studied in protein adsorption experiments. To this aim ATRP initiators were immobilized onto SixN4 through stable Si−C

  17. Effects of divalent cations on vitamin B12 adsorption to brush borders of rat intestine

    International Nuclear Information System (INIS)

    Miyata, Satoru; Inada, Masami

    1976-01-01

    A brush border preparation from rat intestine was incubated with rat intrinsic factor-vitamin B 12 complex in 0.01M Tris-HCl buffer, pH 7.4. The 57 Co-B 12 uptake to brush borders was proportional to the amount of protein or to alkaline phosphatase activity in the preparations. The uptake increased with time of incubation. At 37 0 C, the uptake after incubation for 15 min. was 80-85% of that for one hr. The uptake at 4 0 C was approximately 70% of that at 37 0 C. There was no difference as a result of adding glucose to the incubation medium. The uptake was observed in the alkaline environment above pH 6.3. Maximum uptake occurred at pH 8.0. Brush borders washed with Krebs-Ringer bicarbonate buffer (pH 7.4) exhibited no difference in B 12 uptake, whether in the presence of absence of calcium ion. But brush borders washed with ethylenediaminetetraacetate exhibited no uptake when incubated in calcium-free medium. The uptake reached a maximum by addition of calcium ion at a concentration of 0.3 mM, and was not alter up to 10 mM. Addition of magnesium ion exhibited no uptake. Calcium-dependent B 12 uptake was markedly inhibited by manganese ion. Magnesium ion seemed to slightly inhibit the calcium-dependent uptake. (auth.)

  18. An Eight-Week Clinical Evaluation of an Oscillating-Rotating Power Toothbrush with a Brush Head Utilizing Angled Bristles Compared with a Sonic Toothbrush in the Reduction of Gingivitis and Plaque.

    Science.gov (United States)

    Ccahuana-Vasquez, Renzo A; Conde, Erinn; Grender, Julie M; Cunningham, Pamela; Qaqish, Jimmy; Goyal, C Ram

    2015-01-01

    To evaluate and compare the efficacy of an oscillating-rotating (O-R) power toothbrush with a brush head utilizing angled bristles to a marketed sonic toothbrush in the reduction of plaque and gingivitis over an eight-week period. This study used a randomized, examiner-blind, single-center, two-treatment, parallel group, eight-week design. Subjects with mild-to-moderate plaque and gingivitis were evaluated for baseline whole mouth, gingival margin, and approximal plaque, gingivitis, and gingival bleeding. Clinical assessments were performed using the Modified Gingival Index, Gingival Bleeding Index, and the Rustogi Modified Navy Plaque Index. Subjects received either the O-R brush (Oral-B Professional Care 1000 [D16u] with Oral-B CrossAction brush head [EB50]) or the sonic brush (Sonicare DiamondClean with the standard DiamondClean brush head). Subjects brushed twice daily for two minutes per brushing with the assigned brush and a standard fluoride dentifrice for eight weeks before returning for plaque and gingivitis evaluations using the same methods. Prior to baseline and Week 8 measurements, participants abstained from oral hygiene for 12 hours. One hundred and forty-eight subjects completed the study; 75 in the O-R group and 73 in the sonic group. Both brushes demonstrated statistically significant reductions in plaque and gingivitis over the eight-week study period (p gingivitis than the sonic brush. Whole mouth, gingival margin, and approximal plaque reductions were 27.7%, 46.8%, and 29.3% greater, respectively, compared with the sonic brush, while the reductions in gingivitis, gingival bleeding, and number of bleeding sites were 34.6%, 36.4%, and 36.1% greater, respectively, for the O-R brush than for the sonic brush (p gingivitis reductions for the O-R power brush incorporating the angled-bristled brush head were significantly greater than for the sonic power brush.

  19. Effect of mass variation on dynamics of tethered system in orbital maneuvering

    Science.gov (United States)

    Sun, Liang; Zhao, Guowei; Huang, Hai

    2018-05-01

    In orbital maneuvering, the mass variation due to fuel consumption has an obvious impact on the dynamics of tethered system, which cannot be neglected. The contributions of the work are mainly shown in two aspects: 1) the improvement of the model; 2) the analysis of dynamics characteristics. As the mass is variable, and the derivative of the mass is directly considered in the traditional Lagrange equation, the expression of generalized force is complicated. To solve this problem, the coagulated derivative is adopted in the paper; besides, the attitude dynamics equations derived in this paper take into account the effect of mass variation and the drift of orbital trajectory at the same time. The bifurcation phenomenon, the pendular motion angular frequency, and amplitudes of tether vibration revealed in this paper can provide a reference for the parameters and controller design in practical engineering. In the article, a dumbbell model is adopted to analyze the dynamics of tethered system, in which the mass variation of base satellite is fully considered. Considering the practical application, the case of orbital transfer under a transversal thrust is mainly studied. Besides, compared with the analytical solutions of librational angles, the effects of mass variation on stability and librational characteristic are studied. Finally, in order to make an analysis of the effect on vibrational characteristic, a lumped model is introduced, which reveals a strong coupling of librational and vibrational characteristics.

  20. Calculating the electromagnetic field on the earth due to an electrodynamic tethered system in the ionosphere

    Science.gov (United States)

    Estes, Robert D.

    1989-01-01

    A method is presented for calculating the electromagnetic wave field on the earth's surface associated with the operation of an electrodynamic tethered satellite system of constant or slowly varying current in the upper ionosphere. The wave field at the ionospheric boundary and on the earth's surface is obtained by numerical integration. The results suggest that the ionospheric waves do not propagate into the atmosphere and that the image of the Alfven wings from a steady-current tether should be greatly broadened on the earth's surface.

  1. EUV lithographic radiation grafting of thermo-responsive hydrogel nanostructures

    International Nuclear Information System (INIS)

    Farquet, Patrick; Padeste, Celestino; Solak, Harun H.; Guersel, Selmiye Alkan; Scherer, Guenther G.; Wokaun, Alexander

    2007-01-01

    Nanostructures of the thermoresponsive poly(N-isopropyl acrylamide) (PNIPAAm) and of PNIPAAm-block-poly(acrylic acid) copolymers were produced on poly(tetrafluoroethylene-co-ethyelene) (ETFE) films using extreme ultraviolet (EUV) lithographic exposure with subsequent graft-polymerization. The phase transition of PNIPAAm nanostructures at the low critical solution temperature (LCST) at 32 deg. C was imaged by atomic force microscopy (AFM) phase contrast measurements in pure water. Results show a higher phase contrast for samples measured below the LCST temperature than for samples above the LCST, proving that the soft PNIPAAm hydrogel transforms into a much more compact conformation above the LCST. EUV lithographic exposures were combined with the reversible addition-fragment chain transfer (RAFT)-mediated polymerization using cyanoisopropyl dithiobenzoate (CPDB) as chain transfer agent to synthesize PNIPAAm block-copolymer nanostructures

  2. Elasticity of Hard-Spheres-And-Tether Systems

    International Nuclear Information System (INIS)

    Farago, O.; Kantor, Y.

    1999-01-01

    Physical properties of a large class of systems ranging from noble gases to polymers and rubber are primarily determined by entropy, while the internal energy plays a minor role. Such systems can be conveniently modeled and numerically studied using ''hard' (i.e., ''infinity-or-zero'') potentials, such as hard sphere repulsive interactions, or inextensible (''tether'') bonds which limit the distance between the bonded monomers, but have zero energy at all permitted distances. The knowledge of elastic constants is very important for understanding the behavior of entropy-dominated systems. Computational methods for determination of the elastic constants in such systems are broadly classified into ''strain'' methods and (fluctuation methods. In the former, the elastic constants are extracted from stress-strain relations, while in the latter they are determined from measurements of stress fluctuations. The fluctuation technique usually enables more accurate and well-controlled determination of the elastic constants since in this method the elastic constants are computed directly from simulations of the un strained system with no need to deform the simulation cell and perform numerical differentiations. For central forces systems, the original ''fluctuation'' formalism can be applied provided the pair potential is twice differentiable. We have extended this formalism to apply to hard-spheres-and-tether models in which this requirement is not fulfilled. We found that for such models the components of the tensor of elastic constants can be related to (two-, three- and four-point) probability densities of contacts between hard spheres and stretched bonds. We have tested our formalism on simple (phantom networks and three-dimensional hard spheres systems

  3. The effects of brushing on human enamel surface roughness after NaF gel and theobromine gel exposure

    Science.gov (United States)

    Mahardhika, A.; Noerdin, A.; Eriwati, Y. K.

    2017-08-01

    This study aimed to determine the effects of brushing on human enamel surface roughness after different exposure times of 200 mg/L theobromine gel (8, 16, and 32 minutes) and 2% NaF gel (16 minutes). Twenty-four human upper premolars were used and divided into four groups. Group 1 was exposed to 2% NaF gel for 16 minutes. In contrast, groups 2, 3, and 4 were exposed to 200 mg/L theobromine gel for 8 minutes, 16 minutes, and 32 minutes, and each group was then brushed for 9 minutes and 20 seconds. After the treatment, samples were tested using a surface roughness tester (Mitutoyo SJ 301, Japan). The Wilcoxon test showed significant changes (p enamel surface and then increase roughness after brushing.

  4. Study of the chain microstructure effects on the resulting thermal properties of poly(L-lactide)/poly(N-isopropylacrylamide) biomedical materials

    Energy Technology Data Exchange (ETDEWEB)

    Lizundia, E., E-mail: erlantz.liizundia@ehu.es [Macromolecular Chemistry Research Group (LABQUIMAC), Dept. of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU) (Spain); Meaurio, E., E-mail: emiliano.meaurio@ehu.es [Department of Mining-Metallurgy and Materials Science and BERC POLYMAT, School of Engineering, University of the Basque Country (UPV/EHU) (Spain); Laza, J.M., E-mail: josemanuel.laza@ehu.es [Macromolecular Chemistry Research Group (LABQUIMAC), Dept. of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU) (Spain); Vilas, J.L., E-mail: joseluis.vilas@bcmaterials.net [Basque Center for Materials, Applications and Nanostructures (BCMaterials), Parque Tecnológico de Bizkaia, Ed. 500, Derio 48160 (Spain); León Isidro, L.M., E-mail: luismanuel.leon@ehu.es [Macromolecular Chemistry Research Group (LABQUIMAC), Dept. of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU) (Spain); Basque Center for Materials, Applications and Nanostructures (BCMaterials), Parque Tecnológico de Bizkaia, Ed. 500, Derio 48160 (Spain)

    2015-05-01

    The development of thermally-sensitive poly(N-isopropylacrylamide) (PNIPAAm) and biocompatible/biodegradable poly(L-lactide) (PLLA) blends offers us an efficient strategy in order to obtain materials with improved functional properties to be used in the emerging field of biomedicine. In this sense, thermal properties of PLLA and PNIPAAm have been investigated by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and wide angle X-ray diffraction (WAXD) were conducted to shed more light on the obtained results. For a better understanding of PLLA/PNIPAAm system, both low and high molecular weight PLLA and PNIPAAm have been synthesized by ring opening polymerization and aqueous redox polymerization respectively. Obtained results are interpreted from the viewpoint of chain microstructure of each homopolymer and the ratio between two constituent materials. DSC, SEM and WAXD results show a phase separation over the entire composition range irrespectively of the molecular weight of both homopolymers. Additionally, it was found a nucleating agent behavior of low molecular weight PNIPAAm, while high molecular weight PNIPAAm hinders the crystallization of PLLA. FTIR results suggest that the strong autoassociation present in PNIPAAm plays a key role impairing the miscibility of the whole system. Thermogravimetric analysis reveals that thermodegradation process of PLLA could be continuously delayed with the addition of PNIPAAm due to the increased thermal stability of N-isopropylacrylamide in regard to L-lactide sequences. - Highlights: • Poly(L-lactide)/poly(N-isopropylacrylamide) biomedical materials are synthesized. • Results are interpreted in terms of the building block nature of each constituent. • Phase separation behavior over the entire composition range is achieved. • Strong autoassociation present in PNIPAAm impairs the miscibility of the whole blend

  5. Thermo-responsive poly(N-isopropylacrylamide)-grafted hollow fiber membranes for osteoblasts culture and non-invasive harvest

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Meiling, E-mail: zhuangmeiling2006@126.com; Liu, Tianqing, E-mail: liutq@dlut.edu.cn; Song, Kedong, E-mail: kedongsong@dlut.edu.cn; Ge, Dan, E-mail: gedan@dlut.edu.cn; Li, Xiangqin, E-mail: xiangqinli@163.com

    2015-10-01

    Hollow fiber membrane (HFM) culture system is one of the most important bioreactors for the large-scale culture and expansion of therapeutic cells. However, enzymatic and mechanical treatments are traditionally applied to harvest the expanded cells from HFMs, which inevitably causes harm to the cells. In this study, thermo-responsive cellulose acetate HFMs for cell culture and non-invasive harvest were prepared for the first time via free radical polymerization in the presence of cerium (IV). ATR-FTIR and elemental analysis results indicated that the poly(N-isopropylacrylamide) (PNIPAAm) was covalently grafted on HFMs successfully. Dynamic contact angle measurements at different temperatures revealed that the magnitude of volume phase transition was decreased with increasing grafted amount of PNIPAAm. And the amount of serum protein adsorbed on HFMs surface also displayed the same pattern. Meanwhile osteoblasts adhered and spread well on the surface of PNIPAAm-grafted HFMs at 37 °C. And Calcein-AM/PI staining, AB assay, ALP activity and OCN protein expression level all showed that PNIPAAm-grafted HFMs had good cell compatibility. After incubation at 20 °C for 120 min, the adhering cells on PNIPAAm-grafted HFMs turned to be round and detached after being gently pipetted. These results suggest that thermo-responsive HFMs are attractive cell culture substrates which enable cell culture, expansion and the recovery without proteolytic enzyme treatment for the application in tissue engineering and regenerative medicine. - Highlights: • PNIPAAm-grafted HFMs exhibited thermoresponsive characteristic. • The OB cells could adhere and spread well on the surface of PNIPAAm-grafted HFMs. • PNIPAAm-grafted HFMs do not significantly impact ALP activity and OCN protein expression level of OB cells. • Cell could be detached from PNIPAAm-grafted HFMs when temperature decreased from 37 °C to 20 °C.

  6. [An historical, sociocultural view and in the fiction literature of Bacillus anthracis cases by shaving brushes].

    Science.gov (United States)

    Vázquez-Espinosa, E; Laganà, C; Vazquez, F

    2018-06-01

    In the period from 1915 to 1924 anthrax outbreaks were described by Bacillus anthracis due to the contamination of razor brushes that reached Europe and the United States from areas such as Japan, China or Russia. The brushes were made with badger hair, and then, to reduce the cost with horse hair and other animals. World War I supoosed that the traffics of these brushes, that passed through Europe, changed and the processes of sterilization of the same were deficient giving rise to these outbreaks, that in a percentage of 20% produced the death of the users. The impact of the fashion of wearing a beard, the presence of these cases in the press, in the society of that period, and literature are studied through the work of Agatha Christie who wrote, in 1936, the Hercules Poirot´s novel Cards on the table, and where she describes the murder of one of the characters with the shaving brush contaminated with Bacillus anthracis spores. ©The Author 2018. Published by Sociedad Española de Quimioterapia. This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)(https://creativecommons.org/licenses/by-nc/4.0/).

  7. Badger hair in shaving brushes comes from protected Eurasian badgers

    NARCIS (Netherlands)

    Domingo-Roura, X.; Marmi, J.; Ferrando, A.; López-Giráldez, F.; Macdonald, D.W.; Jansman, H.A.H.

    2006-01-01

    The Eurasian badger (Meles meles) is included in Appendix III of the Bern Convention and protected by national laws in many European countries. Badger hair is used to manufacture luxury shaving brushes, although it is frequently argued that the hog badger (Arctonyx collaris), which in Europe is an

  8. Time and temperature dependent analytical stability of dry-collected Evalyn HPV self-sampling brush for cervical cancer screening

    DEFF Research Database (Denmark)

    Ejegod, Ditte Møller; Pedersen, Helle; Alzua, Garazi Peña

    2018-01-01

    As a new initiative, HPV self-sampling to non-attenders using the dry Evalyn self-sampling brush is offered in the Capital Region of Denmark. The use of a dry brush is largely uncharted territory in terms of analytical stability. In this study we aim to provide evidence on the analytical quality...

  9. Carbon nanotube surface modification with polyelectrolyte brushes endowed with quantum dots and metal oxide nanoparticles through in situ synthesis

    International Nuclear Information System (INIS)

    Llarena, Irantzu; Romero, Gabriela; Moya, Sergio E; Ziolo, Ronald F

    2010-01-01

    Carbon nanotubes (CNTs) have been successfully coated with a covalently bonded polymer brush of negatively charged poly(3-sulfopropylamino methacrylate) (PSPM) by in situ polymerization employing atomic transfer radical polymerization (ATRP) from initiating silanes attached to the CNTs before the polymerization. The CNT-bonded brush forms a polymer layer or shell-like structure around the CNTs and provides colloidal stabilization for the CNTs in aqueous media. In situ syntheses of nanocrystalline CdS and magnetic iron oxide in the polymer brushes lead to the formation of hybrid nanocomposites consisting of nanoparticle-containing PSPM-coated CNTs that remain readily dispersible and stable in aqueous media. The hybrid nanostructures are synthesized by ion exchange with the cations of the sulfonate groups of the PSPM followed by precipitation and were followed by stepwise zeta potential measurements and TEM. Such structures could have applications in the design of more complex structures and devices. The general synthetic scheme can be extended to include other nanoparticles as brush cargo to broaden the utility or functionality of the CNTs. TEM data shows nanocrystalline CdS in the range of 5-8 nm embedded in the PSPM brush and nanocrystalline iron oxide with a size between 2 and 4 nm, with the former consistent with UV-vis spectroscopy and fluorescence measurements.

  10. Green River air quality model development: meteorological and tracer data, July/August 1982 field study in Brush Valley, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Whiteman, C.D.; Lee, R.N.; Orgill, M.M.; Zak, B.D.

    1984-06-01

    Meteorological and atmospheric tracer studies were conducted during a 3-week period in July and August of 1982 in the Brush Creek Valley of northwestern Colorado. The objective of the field experiments was to obtain data to evaluate a model, called VALMET, developed at PNL to predict dispersion of air pollutants released from an elevated stack located within a deep mountain valley in the post-sunrise temperature inversion breakup period. Three tracer experiments were conducted in the valley during the 2-week period. In these experiments, sulfur hexafluoride (SF/sub 6/) was released from a height of approximately 100 m, beginning before sunrise and continuing until the nocturnal down-valley winds reversed several hours after sunrise. Dispersion of the sulfur hexafluoride after release was evaluated by measuring SF/sub 6/ concentrations in ambient air samples taken from sampling devices operated within the valley up to about 8 km down valley from the source. An instrumented research aircraft was also used to measure concentrations in and above the valley. Tracer samples were collected using a network of radio-controlled bag sampling stations, two manually operated gas chromatographs, a continuous SF/sub 6/ monitor, and a vertical SF/sub 6/ profiler. In addition, basic meteorological data were collected during the tracer experiments. Frequent profiles of vertical wind and temperature structure were obtained with tethered balloons operated at the release site and at a site 7.7 km down the valley from the release site. 10 references, 63 figures, 50 tables.

  11. Value of brush cytology for dominant strictures in primary sclerosing cholangitis

    NARCIS (Netherlands)

    Ponsioen, C. Y.; Vrouenraets, S. M.; van Milligen de Wit, A. W.; Sturm, P.; Tascilar, M.; Offerhaus, G. J.; Prins, M.; Huibregtse, K.; Tytgat, G. N.

    1999-01-01

    Around 10% of patients with primary sclerosing cholangitis (PSC) develop cholangiocarcinoma, which is cholangiographically often indistinguishable from a benign dominant stricture. The aim of the present study was to assess the value of brush cytology in discriminating between benign and malignant

  12. Synthesis and characterization of macromolecular rhodamine tethers and their interactions with P-glycoprotein.

    Science.gov (United States)

    Crawford, Lindsey; Putnam, David

    2014-08-20

    Rhodamine dyes are well-known P-glycoprotein (P-gp) substrates that have played an important role in the detection of inhibitors and other substrates of P-gp, as well as in the understanding of P-gp function. Macromolecular conjugates of rhodamines could prove useful as tethers for further probing of P-gp structure and function. Two macromolecular derivatives of rhodamine, methoxypolyethylene glycol-rhodamine6G and methoxypolyethylene glycol-rhodamine123, were synthesized through the 2'-position of rhodamine6G and rhodamine123, thoroughly characterized, and then evaluated by inhibition with verapamil for their ability to interact with P-gp and to act as efflux substrates. To put the results into context, the P-gp interactions of the new conjugates were compared to the commercially available methoxypolyethylene glycol-rhodamineB. FACS analysis confirmed that macromolecular tethers of rhodamine6G, rhodamine123, and rhodamineB were accumulated in P-gp expressing cells 5.2 ± 0.3%, 26.2 ± 4%, and 64.2 ± 6%, respectively, compared to a sensitive cell line that does not overexpress P-gp. Along with confocal imaging, the efflux analysis confirmed that the macromolecular rhodamine tethers remain P-gp substrates. These results open potential avenues for new ways to probe the function of P-gp both in vitro and in vivo.

  13. Streptococcus mutans adhesion to titanium after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use.

    Science.gov (United States)

    Fais, Laiza M G; Carmello, Juliana C; Spolidorio, Denise M P; Adabo, Gelson L

    2013-01-01

    To assess the influence of fluoride on the adhesion of Streptococcus mutans to titanium using an experimental paradigm simulating 10 years of brushing. Commercially pure titanium (cpTi) and titanium alloy (Ti-6Al-4V) disks (6 mm in diameter and 4 mm thick) were mirror-polished and randomly assigned to one of the following six groups (n = 6): immersion (I) or brushing (B) in deionized water (groups IW [control] and BW), fluoride-free toothpaste (groups IT and BT), or fluoridated toothpaste (groups IFT and BFT). Specimens subjected to immersion were statically submerged into the solutions without brushing. For the brushed specimens, a linear brushing machine with a soft-bristled toothbrush was used. The experiments lasted a total of 244 hours. Before and after treatment, the specimens were analyzed under an atomic force microscope to determine the mean roughness (Ra) and the mean of the maximum peak-to-valley heights of the profile (Rtm). The disks were contaminated with standard strains of S mutans in well plates with brain-heart infusion broth. Adhesion was analyzed based on the numbers of colony-forming units (CFU/mL) of adhered viable cells using scanning electronic microscopy. Differences in CFU/mL between the groups were analyzed by one-way analysis of variance. Immersion did not affect either surface. As suggested by Ra and Rtm, BW, BT, and BFT induced changes on the surface of cpTi, whereas only BT and BTF induced changes on the surface of Ti-6Al-4V. No significant differences were observed regarding CFU/mL among the cpTi or Ti-6Al-4V groups. S mutans adhesion was similar for all surfaces. The changes in titanium induced by 10 years of simulated brushing with fluoride toothpaste did not increase the adhesion of S mutans.

  14. Cholesterol-Induced Buckling in Physisorbed Polymer-Tethered Lipid Monolayers

    Directory of Open Access Journals (Sweden)

    Christoph A. Naumann

    2013-04-01

    Full Text Available The influence of cholesterol concentration on the formation of buckling structures is studied in a physisorbed polymer-tethered lipid monolayer system using epifluorescence microscopy (EPI and atomic force microscopy (AFM. The monolayer system, built using the Langmuir-Blodgett (LB technique, consists of 3 mol % poly(ethylene glycol (PEG lipopolymers and various concentrations of the phospholipid, 1-stearoyl-2-oleoyl-sn-glycero-3-phosphocholine (SOPC, and cholesterol (CHOL. In the absence of CHOL, AFM micrographs show only occasional buckling structures, which is caused by the presence of the lipopolymers in the monolayer. In contrast, a gradual increase of CHOL concentration in the range of 0–40 mol % leads to fascinating film stress relaxation phenomena in the form of enhanced membrane buckling. Buckling structures are moderately deficient in CHOL, but do not cause any notable phospholipid-lipopolymer phase separation. Our experiments demonstrate that membrane buckling in physisorbed polymer-tethered membranes can be controlled through CHOL-mediated adjustment of membrane elastic properties. They further show that CHOL may have a notable impact on molecular confinement in the presence of crowding agents, such as lipopolymers. Our results are significant, because they offer an intriguing prospective on the role of CHOL on the material properties in complex membrane architecture.

  15. A novel miniaturized zinc oxide/hydroxylated multiwalled carbon nanotubes as a stir-brush microextractor device for carbamate pesticides analysis

    International Nuclear Information System (INIS)

    Makkliang, Fonthip; Kanatharana, Proespichaya; Thavarungkul, Panote; Thammakhet, Chongdee

    2016-01-01

    A novel miniaturized “stir-brush microextractor” was prepared using a zinc oxide/hydroxylated multiwalled carbon nanotubes (ZnO/MWCNTs–OH) coated stainless steel brush connected to a small dc motor. The synthesized zinc oxide on each strand of stainless steel had a flower-like nanostructure when observed by a scanning electron microscope (SEM). This structure produced a large surface area before it was coated with the hydroxylated multiwalled carbon nanotubes sorbent. Under optimal conditions, the developed device provided a good linearity for the extraction of carbofuran and carbaryl, in the range of 25–500 ng mL"−"1 and 50–500 ng mL"−"1, respectively, with low limits of detection of 17.5 ± 2.0 ng mL"−"1 and 13.0 ± 1.8 ng mL"−"1. It also provided a good stir-brush-to-stir-brush reproducibility (% relative standard deviation < 5.6%, n = 6). The device was applied for the extraction and preconcentration of carbamate pesticides in fruit and vegetable samples prior to analysis with a gas chromatograph coupled with a flame ionization detector (GC–FID). Carbofuran was found at 9.24 ± 0.93 ng g"−"1 and carbaryl was detected at 7.05 ± 0.61 ng g"−"1 with good recoveries in the range of 73.7 ± 10.0% to 108.4 ± 2.6% for carbofuran and 75.7 ± 10.0% to 111.7 ± 5.7% for carbaryl. - Highlights: • A brush as the sampling tool was first introduced. • A novel miniaturized and portable stir brush microextractor was developed for carbamate pesticides extraction. • Large surface area of ZnO flower-like nanostructure coated with MWCNTs–OH on each brush fiber was observed.

  16. A novel miniaturized zinc oxide/hydroxylated multiwalled carbon nanotubes as a stir-brush microextractor device for carbamate pesticides analysis

    Energy Technology Data Exchange (ETDEWEB)

    Makkliang, Fonthip; Kanatharana, Proespichaya [Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Department of Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Thavarungkul, Panote [Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Department of Physics, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Thammakhet, Chongdee, E-mail: chongdee.t@psu.ac.th [Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Department of Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand)

    2016-04-21

    A novel miniaturized “stir-brush microextractor” was prepared using a zinc oxide/hydroxylated multiwalled carbon nanotubes (ZnO/MWCNTs–OH) coated stainless steel brush connected to a small dc motor. The synthesized zinc oxide on each strand of stainless steel had a flower-like nanostructure when observed by a scanning electron microscope (SEM). This structure produced a large surface area before it was coated with the hydroxylated multiwalled carbon nanotubes sorbent. Under optimal conditions, the developed device provided a good linearity for the extraction of carbofuran and carbaryl, in the range of 25–500 ng mL{sup −1} and 50–500 ng mL{sup −1}, respectively, with low limits of detection of 17.5 ± 2.0 ng mL{sup −1} and 13.0 ± 1.8 ng mL{sup −1}. It also provided a good stir-brush-to-stir-brush reproducibility (% relative standard deviation < 5.6%, n = 6). The device was applied for the extraction and preconcentration of carbamate pesticides in fruit and vegetable samples prior to analysis with a gas chromatograph coupled with a flame ionization detector (GC–FID). Carbofuran was found at 9.24 ± 0.93 ng g{sup −1} and carbaryl was detected at 7.05 ± 0.61 ng g{sup −1} with good recoveries in the range of 73.7 ± 10.0% to 108.4 ± 2.6% for carbofuran and 75.7 ± 10.0% to 111.7 ± 5.7% for carbaryl. - Highlights: • A brush as the sampling tool was first introduced. • A novel miniaturized and portable stir brush microextractor was developed for carbamate pesticides extraction. • Large surface area of ZnO flower-like nanostructure coated with MWCNTs–OH on each brush fiber was observed.

  17. Enhancement of plaque removal efficacy by tooth brushing with baking soda dentifrices: results of five clinical studies.

    Science.gov (United States)

    Putt, Mark S; Milleman, Kimberly R; Ghassemi, Annahita; Vorwerk, Linda M; Hooper, William J; Soparkar, Pramod M; Winston, Anthony E; Proskin, Howard M

    2008-01-01

    An earlier clinical study demonstrated that brushing with a commercial Arm & Hammer dentifrice containing baking soda physically removed significantly more plaque than brushing with either of two commercial dentifrices which did not contain baking soda. However, little has been done to confirm these results and to compare baking soda-containing dentifrices with more recently commercialized non-baking soda dentifrice formulations. The objective of this study was to compare commercial dentifrices containing 20% to 65% baking soda and commercial dentifrices without baking soda in enhancing plaque removal efficacy of tooth brushing. Five randomized, controlled, blinded, crossover clinical studies were performed among healthy adult volunteers who provided informed consent. After approximately 24 hours without oral hygiene, subjects with sufficient plaque were enrolled in the study phase. Plaque was scored before and after supervised brushing for one minute using the Turesky, et al. modification of the Quigley-Hein Plaque Index at six sites per tooth according to Soparkar's modification as described by Lobene, et al. In each study, wash-out periods with a regular dentifrice not evaluated in the study separated each product treatment. In all studies, every dentifrice exhibited a significant (p baking soda dentifrices resulted in statistically greater (p baking soda. Results on other tooth surfaces, such as facial, lingual, proximal, and gingival surfaces also demonstrated statistically greater (p baking soda-containing dentifrices as compared to the baking soda-free dentifrices. In three of the studies comparing different levels of baking soda, brushing with dentifrices with higher concentrations of baking soda consistently removed numerically more plaque than those containing lower levels. In one of these three studies, the difference in plaque removal between the baking soda dentifrices reached statistical significance. The results suggest a positive relationship

  18. Use of Tethered Enzymes as a Platform Technology for Rapid Analyte Detection

    Science.gov (United States)

    Cohen, Roy; Lata, James P.; Lee, Yurim; Hernández, Jean C. Cruz; Nishimura, Nozomi; Schaffer, Chris B.; Mukai, Chinatsu; Nelson, Jacquelyn L.; Brangman, Sharon A.; Agrawal, Yash; Travis, Alexander J.

    2015-01-01

    Background Rapid diagnosis for time-sensitive illnesses such as stroke, cardiac arrest, and septic shock is essential for successful treatment. Much attention has therefore focused on new strategies for rapid and objective diagnosis, such as Point-of-Care Tests (PoCT) for blood biomarkers. Here we use a biomimicry-based approach to demonstrate a new diagnostic platform, based on enzymes tethered to nanoparticles (NPs). As proof of principle, we use oriented immobilization of pyruvate kinase (PK) and luciferase (Luc) on silica NPs to achieve rapid and sensitive detection of neuron-specific enolase (NSE), a clinically relevant biomarker for multiple diseases ranging from acute brain injuries to lung cancer. We hypothesize that an approach capitalizing on the speed and catalytic nature of enzymatic reactions would enable fast and sensitive biomarker detection, suitable for PoCT devices. Methods and findings We performed in-vitro, animal model, and human subject studies. First, the efficiency of coupled enzyme activities when tethered to NPs versus when in solution was tested, demonstrating a highly sensitive and rapid detection of physiological and pathological concentrations of NSE. Next, in rat stroke models the enzyme-based assay was able in minutes to show a statistically significant increase in NSE levels in samples taken 1 hour before and 0, 1, 3 and 6 hours after occlusion of the distal middle cerebral artery. Finally, using the tethered enzyme assay for detection of NSE in samples from 20 geriatric human patients, we show that our data match well (r = 0.815) with the current gold standard for biomarker detection, ELISA—with a major difference being that we achieve detection in 10 minutes as opposed to the several hours required for traditional ELISA. Conclusions Oriented enzyme immobilization conferred more efficient coupled activity, and thus higher assay sensitivity, than non-tethered enzymes. Together, our findings provide proof of concept for using

  19. Development of injectable hydrogels for nucleus pulposus replacement

    Science.gov (United States)

    Thomas, Jonathan D.

    Intervertebral disc degeneration has been reported as the underlying cause for 75% of cases of lower back pain and is marked by dehydration of the nucleus pulposus within the intervertebral disc. There have been many implant designs to replace the nucleus pulposus. Some researchers have proposed the replacement of the nucleus pulposus with hydrogel materials. The insertion of devices made from these materials further compromises the annulus of the disc. An ideal nucleus replacement could be injected into the disc space and form a solid in vivo. However, injectable replacements using curing elastomers and thermoplastic materials are not ideal because of the potentially harmful exothermic heat evolved from their reactions and the toxicity of the reactants used. We propose a hydrogel system that can be injected as a liquid at 25°C and solidified to yield a hydrogel within the intervertebral disc at 37°C. In aqueous solutions, these polymers have Lower Critical Solution Temperatures (LCST) between 25-37°C, making them unique candidate materials for this application. Poly(N-isopropylacrylamide) (PNIPAAm) is the most widely studied LCST polymer due to its drastic transition near body temperature. However, by itself, pure PNIPAAm forms a hydrogel that has low water content and can readily undergo plastic deformation. To increase the water content and impart elasticity to PNIPAAm hydrogels, grafted and branched hydrogel systems were created that incorporated the thermogelling PNIPAAm and hydrophilic poly(ethylene glycol) (PEG). In this research, the effects of polymer composition and monomer to initiator ratio, which controls polymer MW, on the in vitro swelling properties (mass, chemical, and compressive mechanical stability) of hydrogels formed from aqueous solutions of these polymers were evaluated. Immersion studies were also conducted in solutions to simulate the osmotic environment of the nucleus pulposus. The effects of repeated compression and unloading cycles

  20. Synthesis and conformational characterization of functional di-block copolymer brushes for microarray technology

    Energy Technology Data Exchange (ETDEWEB)

    Di Carlo, Gabriele; Damin, Francesco [Institute of Chemistry of Molecular Recognition, National Research Council of Italy, Via M. Bianco 9, 20131 Milano (Italy); Armelao, Lidia [ISTM-CNR and INSTM, Department of Chemistry, University of Padova, Via F. Marzolo 1, 35131 Padova (Italy); Maccato, Chiara [Department of Chemistry and INSTM, University of Padova, Via F. Marzolo 1, 35131 Padova (Italy); Unlu, Selim [Department of Electrical and Computer Engineering, Boston University, St. Mary Street 8, Boston, MA 02215 (United States); Department of Biomedical Engineering, Boston University, St. Mary Street 8, Boston, MA 02215 (United States); Spuhler, Philipp S. [Department of Biomedical Engineering, Boston University, St. Mary Street 8, Boston, MA 02215 (United States); Chiari, Marcella, E-mail: marcella.chiari@icrm.cnr.it [Institute of Chemistry of Molecular Recognition, National Research Council of Italy, Via M. Bianco 9, 20131 Milano (Italy)

    2012-02-01

    Surface initiated polymerization (SIP) coupled with reversible addition-fragmentation chain transfer polymerization (RAFT) was used to functionalize microarray glass slides with block polymer brushes. N,N-dimethylacrylamide (DMA) and N-acryloyloxysuccinimide (NAS) (graft-poly[DMA-b-(DMA-co-NAS)]) brushes, with di-block architecture, were prepared from a novel RAFT chain transfer agent bearing a silanating moiety (RAFT silane) directly anchored onto the glass surfaces. Conformational characterization of the coatings was performed by Self Spectral Interference Fluorescence Microscopy (SSFM), an innovative technique that describes the location of a fluorescent DNA molecule relative to a surface with sub-nanometer accuracy. X-ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscopy (SEM) were used to characterize the coatings composition and morphology.

  1. Synthesis and conformational characterization of functional di-block copolymer brushes for microarray technology

    International Nuclear Information System (INIS)

    Di Carlo, Gabriele; Damin, Francesco; Armelao, Lidia; Maccato, Chiara; Unlu, Selim; Spuhler, Philipp S.; Chiari, Marcella

    2012-01-01

    Surface initiated polymerization (SIP) coupled with reversible addition-fragmentation chain transfer polymerization (RAFT) was used to functionalize microarray glass slides with block polymer brushes. N,N-dimethylacrylamide (DMA) and N-acryloyloxysuccinimide (NAS) (graft-poly[DMA-b-(DMA-co-NAS)]) brushes, with di-block architecture, were prepared from a novel RAFT chain transfer agent bearing a silanating moiety (RAFT silane) directly anchored onto the glass surfaces. Conformational characterization of the coatings was performed by Self Spectral Interference Fluorescence Microscopy (SSFM), an innovative technique that describes the location of a fluorescent DNA molecule relative to a surface with sub-nanometer accuracy. X-ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscopy (SEM) were used to characterize the coatings composition and morphology.

  2. On the effect of tether composition on cis/trans selectivity in intramolecular Diels-Alder reactions.

    Science.gov (United States)

    Paddon-Row, Michael N; Longshaw, Alistair I; Willis, Anthony C; Sherburn, Michael S

    2009-01-05

    Intramolecular Diels-Alder (IMDA) transition structures (TSs) and energies have been computed at the B3LYP/6-31+G(d) and CBS-QB3 levels of theory for a series of 1,3,8-nonatrienes, H(2)C=CH-CH=CH-CH(2)-X-Z-CH=CH(2) [-X-Z- = -CH(2)-CH(2)- (1); -O-C(=O)- (2); -CH(2)-C(=O)- (3); -O-CH(2)- (4); -NH-C(=O)- (5); -S-C(=O)- (6); -O-C(=S)- (7); -NH-C(=S)- (8); -S-C(=S)- (9)]. For each system studied (1-9), cis- and trans-TS isomers, corresponding, respectively, to endo- and exo-positioning of the -C-X-Z- tether with respect to the diene, have been located and their relative energies (E(rel) (TS)) employed to predict the cis/trans IMDA product ratio. Although the E(rel) (TS) values are modest (typically NH or S), the IMDA cis stereoselectivity diminishes. The predicted stereochemical reaction preferences are explained in terms of two opposing effects operating in the cis-TS, namely (1) unfavorable torsional (eclipsing) strain about the C4-C5 bond, that is caused by the -C-X-C(=Y)- group's strong tendency to maintain local planarity; and (2) attractive electrostatic and secondary orbital interactions between the endo-(thio)carbonyl group, C=Y, and the diene. The former interaction predominates when X is weakly electronegative (X=N, S), while the latter is dominant when X is more strongly electronegative (X=O), or a methylene group (X=CH(2)) which increases tether flexibility. These predictions hold up to experimental scrutiny, with synthetic IMDA reactions of 1, 2, 3, and 4 (published work) and 5, 6, and 8 (this work) delivering ratios close to those calculated. The reactions of thiolacrylate 5 and thioamide 8 represent the first examples of IMDA reactions with tethers of these types. Our results point to strategies for designing tethers, which lead to improved cis/trans-selectivities in IMDAs that are normally only weakly selective. Experimental verification of the validity of this claim comes in the form of fumaramide 14, which undergoes a more trans-selective IMDA reaction

  3. The combined effect of food-simulating solutions, brushing and staining on color stability of composite resins

    Science.gov (United States)

    Silva, Tânia Mara Da; Sales, Ana Luísa Leme Simões; Pucci, Cesar Rogerio; Borges, Alessandra Bühler; Torres, Carlos Rocha Gomes

    2017-01-01

    Abstract Objective: This study evaluated the effect of food-simulating media associated with brushing and coffee staining on color stability of different composite resins. Materials and methods: Eighty specimens were prepared for each composite: Grandio SO (Voco), Amaris (Voco), Filtek Z350XT (3M/ESPE), Filtek P90 (3M/ESPE). They were divided into four groups according to food-simulating media for 7 days: artificial saliva (control), heptane, citric acid and ethanol. The composite surface was submitted to 10,950 brushing cycles (200 g load) in an automatic toothbrushing machine. The specimens were darkened with coffee solution at 37 °C for 24 h. After each treatment, color measurements were assessed by spectrophotometry, using CIE L*a*b* system. The overall color change (ΔE) was determined for each specimen at baseline (C1) and after the treatments (food-simulating media immersion/C2, brushing/C3 and dye solution/C4). Data were analyzed by two-way repeated measures ANOVA and Tukey’s tests (p composites (p = .001), time (p = .001) and chemical degradation (p = .002). The mean of ΔE for composites were: Z350XT (5.39)a, Amaris (3.89)b, Grandio (3.75)bc, P90 (3.36)c. According to food-simulating media: heptane (4.41)a, citric acid (4.24)a, ethanol (4.02)ab, artificial saliva (3.76)b. For the treatments: dye solution (4.53)a, brushing (4.26)a, after food-simulating media (3.52)b. Conclusions: The composite resin Filtek Z350XT showed significantly higher staining than all other composite resin tested. The immersion in heptane and citric acid produced the highest color alteration than other food-simulating media. The exposure of samples to brushing protocols and darkening in coffee solution resulted in significant color alteration of the composite resins. PMID:28642926

  4. Protein valves prepared by click reaction grafting of poly(N-isopropylacrylamide) to electrospun poly(vinyl chloride) fibrous membranes

    Science.gov (United States)

    Guo, Jian-Wei; Lin, Zhen-Yu; Chang, Chi-Jung; Lu, Chien-Hsing; Chen, Jem-Kun

    2018-05-01

    In this study, poly(vinyl chloride) (PVC) was electrospun into fibrous membranes and then reacted with NaN3 to generate azido-terminated PVC fibrous membranes. A propargyl-terminated poly(N-isopropylacrylamide) (PNIPAAm) was also synthesized and then grafted, through click reactions, onto the azido-terminated PVC fiber surface. Protrusion-, scale-, and joint-like structures of the PNIPAAm grafts on the PVC fibers were formed upon increasing the molecular weight of the PNIPAAm grafts. The PNIPAAm-grafted PVC fibrous mats exhibited completely wetted surfaces at 25 °C because of their high roughness. The static water contact angle of the PNIPAAm-grafted PVC fibrous mats reached 140° when the temperature was increased to 45 °C. This thermoresponsive behavior was significantly greater than that of the PNIPAAm grafted on a flat surface. Temperature-responsive membranes were constructed having a pore size of 1.38 μm and applied as protein valves to block and release an antibody (fluorescein-conjugated AffiniPure goat anti-rabbit IgG). At 25 °C, the collection efficiency remained at 94% for antibody concentrations up to 60 ng/L. As the temperature increased to 45 °C, the collection efficiency decreased abruptly, to 4%, when the antibody concentration was greater than 20 ng/L. Accordingly, this system of PNIPAAm-grafted PVC fibers functioned as a protein valve allowing the capture and concentration of proteins.

  5. The effect of particle size on the morphology and thermodynamics of diblock copolymer/tethered-particle membranes

    International Nuclear Information System (INIS)

    Zhang, Bo; Edwards, Brian J.

    2015-01-01

    A combination of self-consistent field theory and density functional theory was used to examine the effect of particle size on the stable, 3-dimensional equilibrium morphologies formed by diblock copolymers with a tethered nanoparticle attached either between the two blocks or at the end of one of the blocks. Particle size was varied between one and four tenths of the radius of gyration of the diblock polymer chain for neutral particles as well as those either favoring or disfavoring segments of the copolymer blocks. Phase diagrams were constructed and analyzed in terms of thermodynamic diagrams to understand the physics associated with the molecular-level self-assembly processes. Typical morphologies were observed, such as lamellar, spheroidal, cylindrical, gyroidal, and perforated lamellar, with the primary concentration region of the tethered particles being influenced heavily by particle size and tethering location, strength of the particle-segment energetic interactions, chain length, and copolymer radius of gyration. The effect of the simulation box size on the observed morphology and system thermodynamics was also investigated, indicating possible effects of confinement upon the system self-assembly processes

  6. The effect of particle size on the morphology and thermodynamics of diblock copolymer/tethered-particle membranes.

    Science.gov (United States)

    Zhang, Bo; Edwards, Brian J

    2015-06-07

    A combination of self-consistent field theory and density functional theory was used to examine the effect of particle size on the stable, 3-dimensional equilibrium morphologies formed by diblock copolymers with a tethered nanoparticle attached either between the two blocks or at the end of one of the blocks. Particle size was varied between one and four tenths of the radius of gyration of the diblock polymer chain for neutral particles as well as those either favoring or disfavoring segments of the copolymer blocks. Phase diagrams were constructed and analyzed in terms of thermodynamic diagrams to understand the physics associated with the molecular-level self-assembly processes. Typical morphologies were observed, such as lamellar, spheroidal, cylindrical, gyroidal, and perforated lamellar, with the primary concentration region of the tethered particles being influenced heavily by particle size and tethering location, strength of the particle-segment energetic interactions, chain length, and copolymer radius of gyration. The effect of the simulation box size on the observed morphology and system thermodynamics was also investigated, indicating possible effects of confinement upon the system self-assembly processes.

  7. Otolith tethering in the zebrafish otic vesicle requires Otogelin and α-Tectorin.

    Science.gov (United States)

    Stooke-Vaughan, Georgina A; Obholzer, Nikolaus D; Baxendale, Sarah; Megason, Sean G; Whitfield, Tanya T

    2015-03-15

    Otoliths are biomineralised structures important for balance and hearing in fish. Their counterparts in the mammalian inner ear, otoconia, have a primarily vestibular function. Otoliths and otoconia form over sensory maculae and are attached to the otolithic membrane, a gelatinous extracellular matrix that provides a physical coupling between the otolith and the underlying sensory epithelium. In this study, we have identified two proteins required for otolith tethering in the zebrafish ear, and propose that there are at least two stages to this process: seeding and maintenance. The initial seeding step, in which otolith precursor particles tether directly to the tips of hair cell kinocilia, fails to occur in the einstein (eis) mutant. The gene disrupted in eis is otogelin (otog); mutations in the human OTOG gene have recently been identified as causative for deafness and vestibular dysfunction (DFNB18B). At later larval stages, maintenance of otolith tethering to the saccular macula is dependent on tectorin alpha (tecta) function, which is disrupted in the rolling stones (rst) mutant. α-Tectorin (Tecta) is a major constituent of the tectorial membrane in the mammalian cochlea. Mutations in the human TECTA gene can cause either dominant (DFNA8/12) or recessive (DFNB21) forms of deafness. Our findings indicate that the composition of extracellular otic membranes is highly conserved between mammals and fish, reinforcing the view that the zebrafish is an excellent model system for the study of deafness and vestibular disease. © 2015. Published by The Company of Biologists Ltd.

  8. Tethered Balloon Operations at ARM AMF3 Site at Oliktok Point, AK

    Science.gov (United States)

    Dexheimer, D.; Lucero, D. A.; Helsel, F.; Hardesty, J.; Ivey, M.

    2015-12-01

    Oliktok Point has been the home of the Atmospheric Radiation Measurement Program's (ARM) third ARM Mobile Facility, or AMF3, since October 2013. The AMF3 is operated through Sandia National Laboratories and hosts instrumentation collecting continuous measurements of clouds, aerosols, precipitation, energy, and other meteorological variables. The Arctic region is warming more quickly than any other region due to climate change and Arctic sea ice is declining to record lows. Sparsity of atmospheric data from the Arctic leads to uncertainty in process comprehension, and atmospheric general circulation models (AGCM) are understood to underestimate low cloud presence in the Arctic. Increased vertical resolution of meteorological properties and cloud measurements will improve process understanding and help AGCMs better characterize Arctic clouds. SNL is developing a tethered balloon system capable of regular operation at AMF3 in order to provide increased vertical resolution atmospheric data. The tethered balloon can be operated within clouds at altitudes up to 7,000' AGL within DOE's R-2204 restricted area. Pressure, relative humidity, temperature, wind speed, and wind direction are recorded at multiple altitudes along the tether. These data were validated against stationary met tower data in Albuquerque, NM. The altitudes of the sensors were determined by GPS and calculated using a line counter and clinometer and compared. Wireless wetness sensors and supercooled liquid water content sensors have also been deployed and their data has been compared with other sensors. This presentation will provide an overview of the balloons, sensors, and test flights flown, and will provide a preliminary look at data from sensor validation campaigns and test flights.

  9. Karyotype analysis and sex determination in Australian Brush-turkeys (Alectura lathami.

    Directory of Open Access Journals (Sweden)

    Madison T Ortega

    Full Text Available Sexual differentiation across taxa may be due to genetic sex determination (GSD and/or temperature sex determination (TSD. In many mammals, males are heterogametic (XY; whereas females are homogametic (XX. In most birds, the opposite is the case with females being heterogametic (ZW and males the homogametic sex (ZZ. Many reptile species lack sex chromosomes, and instead, sexual differentiation is influenced by temperature with specific temperatures promoting males or females varying across species possessing this form of sexual differentiation, although TSD has recently been shown to override GSD in Australian central beaded dragons (Pogona vitticeps. There has been speculation that Australian Brush-turkeys (Alectura lathami exhibit TSD alone and/or in combination with GSD. Thus, we sought to determine if this species possesses sex chromosomes. Blood was collected from one sexually mature female and two sexually mature males residing at Sylvan Heights Bird Park (SHBP and shipped for karyotype analysis. Karyotype analysis revealed that contrary to speculation, Australian Brush-turkeys possess the classic avian ZW/ZZ sex chromosomes. It remains a possibility that a biased primary sex ratio of Australian Brush-turkeys might be influenced by maternal condition prior to ovulation that result in her laying predominantly Z- or W-bearing eggs and/or sex-biased mortality due to higher sensitivity of one sex in environmental conditions. A better understanding of how maternal and extrinsic factors might differentially modulate ovulation of Z- or W-bearing eggs and hatching of developing chicks possessing ZW or ZZ sex chromosomes could be essential in conservation strategies used to save endangered members of Megapodiidae.

  10. Numerical simulation of flow in Brush Creek Valley, Colorado

    International Nuclear Information System (INIS)

    Leone, J.M. Jr.; Lee, R.L.

    1987-06-01

    In this paper, we present some results from our three-dimensional, non-hydrostatic, finite element model applied to simulations of flow in Brush Creek Valley. These simulations are not intended to reproduce any particular experiment, but rather are to evaluate the qualitative performance of the model, to explore the major difficulties involved, and to begin sensitivity studies of the flows of interest. 2 refs., 11 figs

  11. Clinical evaluation of an ionic tooth brush on oral hygiene status, gingival status, and microbial parameter

    Directory of Open Access Journals (Sweden)

    Deshmukh J

    2006-01-01

    Full Text Available It has long been recognised that the presence of dental plaque leads to gingivitis and periodontal disease, as well as dental caries. Today tooth brushing is the most widely accepted method of removing plaque. Hence this present clinical study was undertaken to evaluate the effectiveness of an ionic toothbrush on oral hygiene status. For this study, 20 dental students in the age group of 18-20 years were included. All the subjects after undergoing dental prophylaxis were then provided with ionic toothbrushes, either active (equipped with lithium battery or inactive (without lithium battery. Plaque index and gingival bleeding index were examined at 7th, 14th, and 21st day. Microbial assessment was done for detection of colony forming units (CFU from the plaque samples which were collected on 0 day and 21st day, both before brushing and after brushing. Results shown a significant reduction in all the parameters and the reduction was more significant in active and inactive ionic toothbrush users. It was concluded that both active and inactive ionic toothbrushes reduced the plaque index and gingival bleeding index scores significantly and active ionic tooth brushes were more effective as compared to inactive ionic toothbrushes. There was no soft tissue trauma following the use of both type of toothbrushes, which showed that ionic toothbrushes were equally safe for regular long-term use.

  12. Controlled growth of protein resistant PHEMA brushes via S-RAFT polymerization

    Czech Academy of Sciences Publication Activity Database

    Zamfir, M.; Rodriguez-Emmenegger, Cesar; Bauer, S.; Barner, L.; Rosenhahn, A.; Barner-Kowollik, C.

    2013-01-01

    Roč. 1, č. 44 (2013), s. 6027-6034 ISSN 2050-750X R&D Projects: GA ČR GAP205/12/1702; GA ČR GAP106/12/1451 Institutional support: RVO:61389013 Keywords : surface RAFT * polymer brushes * antifouling Subject RIV: CD - Macromolecular Chemistry

  13. Synthesis of novel glycopolymer brushes via a combination of RAFT-mediated polymerisation and ATRP

    Directory of Open Access Journals (Sweden)

    Eric T.A. van den Dungen

    2011-03-01

    Full Text Available Glycopolymers (synthetic sugar-containing polymers have become increasingly attractive to polymer chemists because of their role as biomimetic analogues and their potential for commercial applications. Glycopolymers of different structures confer high hydrophilicity and water solubility and can therefore be used for specialised applications, such as artificial materials for a number of biological, pharmaceutical and biomedical uses. The synthesis and characterisation of a series of novel glycopolymer brushes, namely poly(2-(2-bromoisobutyryloxy ethyl methacrylate-g-poly(methyl 6-O-methacryloyl-α-D-glucoside (P(BIEM-g-P(6-O-MMAGIc, poly(2-(2-bromoisobutyryloxy ethyl methacrylate-co-methyl methacrylate-g-poly(methyl 6-O-methacryloyl-α-D-glucoside P(BIEM-co-MMA-g-P(6-O-MMAGIc, poly(2-(2-bromoisobutyryloxy ethyl methacrylate-b-methyl methacrylate-g-poly(methyl 6-O-methacryloyl-α-D-glucoside P(BIEM-b-MMA-g-P(6-O-MMAGIc and poly(4-vinylbenzyl chloride-alt-maleic anhydride-g-poly(methyl 6-O-methacryloyl-α-D-glucoside (P(Sd-alt-MAnh-g-P(6-O-MMAGIc are described in this paper. Reversible addition-fragmentation chain transfer (RAFT-mediated polymerisation was used to synthesise four well-defined atom transfer radical polymerisation (ATRP macroinitiators (the backbone of the glycopolymer brushes. These ATRP macroinitiators were subsequently used in the ‘grafting from’ approach (in which side chains are grown from the backbone to prepare high molar mass and low polydispersity index glycopolymer brushes with different grafting densities along the backbone. The number average molar mass of the glycopolymer brushes was determined using size exclusion chromatography with a multi-angle laser light

  14. The Tethered Balloon Current Generator - A space shuttle-tethered subsatellite for plasma studies and power generation

    Science.gov (United States)

    Williamson, P. R.; Banks, P. M.

    1976-01-01

    The objectives of the Tethered Balloon Current Generator experiment are to: (1) generate relatively large regions of thermalized, field-aligned currents, (2) produce controlled-amplitude Alfven waves, (3) study current-driven electrostatic plasma instabilities, and (4) generate substantial amounts of power or propulsion through the MHD interaction. A large balloon (a diameter of about 30 m) will be deployed with a conducting surface above the space shuttle at a distance of about 10 km. For a generally eastward directed orbit at an altitude near 400 km, the balloon, connected to the shuttle by a conducting wire, will be positive with respect to the shuttle, enabling it to collect electrons. At the same time, the shuttle will collect positive ions and, upon command, emit an electron beam to vary current flow in the system.

  15. Extreme delta brush: a unique EEG pattern in adults with anti-NMDA receptor encephalitis.

    Science.gov (United States)

    Schmitt, Sarah E; Pargeon, Kimberly; Frechette, Eric S; Hirsch, Lawrence J; Dalmau, Josep; Friedman, Daniel

    2012-09-11

    To determine continuous EEG (cEEG) patterns that may be unique to anti-NMDA receptor (NMDAR) encephalitis in a series of adult patients with this disorder. We evaluated the clinical and EEG data of 23 hospitalized adult patients with anti-NMDAR encephalitis who underwent cEEG monitoring between January 2005 and February 2011 at 2 large academic medical centers. Twenty-three patients with anti-NMDAR encephalitis underwent a median of 7 (range 1-123) days of cEEG monitoring. The median length of hospitalization was 44 (range 2-200) days. Personality or behavioral changes (100%), movement disorders (82.6%), and seizures (78.3%) were the most common symptoms. Seven of 23 patients (30.4%) had a unique electrographic pattern, which we named "extreme delta brush" because of its resemblance to waveforms seen in premature infants. The presence of extreme delta brush was associated with a more prolonged hospitalization (mean 128.3 ± 47.5 vs 43.2 ± 39.0 days, p = 0.008) and increased days of cEEG monitoring (mean 27.6 ± 42.3 vs 6.2 ± 5.6 days, p = 0.012). The modified Rankin Scale score showed a trend toward worse scores in patients with the extreme delta brush pattern (mean 4.0 ± 0.8 vs 3.1 ± 1.1, p = 0.089). Extreme delta brush is a novel EEG finding seen in many patients with anti-NMDAR encephalitis. The presence of this pattern is associated with a more prolonged illness. Although the specificity of this pattern is unclear, its presence should raise consideration of this syndrome.

  16. Structure and rheology of nanoparticle–polymer suspensions

    KAUST Repository

    Srivastava, Samanvaya

    2012-01-01

    Structure and rheology of oligomer-tethered nanoparticles suspended in low molecular weight polymeric host are investigated at various particle sizes and loadings. Strong curvature effects introduced by the small size of the nanoparticle cores are found to be important for understanding both the phase stability and rheology of the materials. Small angle X-ray scattering (SAXS) and transmission electron microscopy measurements indicate that PEG-SiO 2/PEG suspensions are more stable against phase separation and aggregation than expected from theory for interacting brushes. SAXS and rheology measurements also reveal that at high particle loadings, the stabilizing oligomer brush is significantly compressed and produces jamming in the suspensions. The jamming transition is accompanied by what appears to be a unique evolution in the transient suspension rheology, along with large increments in the zero-shear, Newtonian viscosity. The linear and nonlinear flow responses of the jammed suspensions are discussed in the framework of the Soft Glassy Rheology (SGR) model, which is shown to predict many features that are consistent with experimental observations, including a two-step relaxation following flow cessation and a facile method for determining the shear-thinning coefficient from linear viscoelastic measurements. Finally, we show that the small sizes of the particles have a significant effect on inter-particle interactions and rheology, leading to stronger deviations from expectations based on planar brushes and hard-sphere suspension theories. In particular, we find that in the high volume fraction limit, tethered nanoparticles interact in their host polymer through short-range forces, which are more analogous to those between soft particles than between spherical polymer brushes. © 2012 The Royal Society of Chemistry.

  17. Molecular aggregation states of poly{l_brace}2-(perfluorooctyl)ethyl acrylate{r_brace} polymer brush thin film analyzed by grazing incidence X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, H; Honda, K; Takahara, A [Graduate School of Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Kobayashi, M [Institute for Materials Chemistry and Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Morita, M [Fundamental Research Department, Chemical Division, Daikin Industries, Ltd., 1-1 Nishi Hitotsuya, Settsu-shi, Osaka 566-8585 (Japan); Masunaga, H; Sasaki, S; Takata, M [Japan Synchrotron Research Institute, Mikazuki Sayo, Hyogo 671-5198 (Japan); Sakata, O, E-mail: takahara@cstf.kyushu-u.ac.j [RIKEN Harima Institute, Mikazuki Sayo, Hyogo 671-5198 (Japan)

    2009-08-01

    Fluoropolymer brush with crystalline side chains was prepared by surface-initiated atom transfer radical polymerization of 2-(perfluorooctyl)ethyl acrylate (FA-C{sub 8}) from a flat silicon substrate. The crystallization and the molecular aggregation structures of polymer side chain at the outermost surface and internal region in the brush film were characterized by grazing incidence X-ray diffraction (GIXD) measurement using two different incident angles of X-ray. At the air interface of PFA-C{sub 8} brush film, the rod-like R{sub f} group was oriented perpendicular to the surface forming a hexagonal packing structure to reduce surface energy. In contrast, the oriented R{sub f} groups parallel to the substrate coexisted at the internal region in the brush. This unique depth dependence of crystalline state of the fluoropolymer brush was observed by surface-sensitive GIXD measurement.

  18. Helicobacter pylori in dental plaque; is it related to brushing frequency, plaque load and oral health status?

    Science.gov (United States)

    Chaudhry, Saima; Khan, Ayyaz Ali; Butt, Arshad Kamal; Idrees, Muhammad; Izhar, Mateen; Iqbal, Hafiz Aamer

    2011-10-01

    To determine the relation between presence of H. pylori in supra-gingival dental plaque with oral hygiene habits and oral health status of patients suffering from symptomatic dyspepsia. Descriptive study. The Department of Oral Health Sciences, Shaikh Zayed FPGMI, Lahore, from September 2008 to August 2009. One hundred and fifty dyspeptic subjects with dental plaque were enrolled. After recording brushing frequency, oral health status and plaque load, the supra-gingival dental plaque samples were collected by sterile curettes. Helicobacter pylori were detected in dental plaque samples through PCR assay. Presence of H. pylori in dental plaque was found to be 37.5% in the sample. Most of the subjects brushed once daily, had plaque index score of 1 and had fair to poor oral hygiene status. Approximately 35% of the individuals who brushed once or twice a day harbored the bacterium in their dental plaque. There was no difference between bacterial detection rates among different categories of plaque index and oral health status of the study subjects. Presence of H. pylori in dental plaque was found to be associated with neither brushing frequency nor with the plaque load nor with the oral health status of individuals suffering from symptomatic dyspepsia.

  19. Nuclear pore complex tethers to the cytoskeleton.

    Science.gov (United States)

    Goldberg, Martin W

    2017-08-01

    The nuclear envelope is tethered to the cytoskeleton. The best known attachments of all elements of the cytoskeleton are via the so-called LINC complex. However, the nuclear pore complexes, which mediate the transport of soluble and membrane bound molecules, are also linked to the microtubule network, primarily via motor proteins (dynein and kinesins) which are linked, most importantly, to the cytoplasmic filament protein of the nuclear pore complex, Nup358, by the adaptor BicD2. The evidence for such linkages and possible roles in nuclear migration, cell cycle control, nuclear transport and cell architecture are discussed. Copyright © 2017. Published by Elsevier Ltd.

  20. Approaching control for tethered space robot based on disturbance observer using super twisting law

    Science.gov (United States)

    Hu, Yongxin; Huang, Panfeng; Meng, Zhongjie; Wang, Dongke; Lu, Yingbo

    2018-05-01

    Approaching control is a key mission for the tethered space robot to perform the task of removing space debris. But the uncertainties of the TSR such as the change of model parameter have an important effect on the approaching mission. Considering the space tether and the attitude of the gripper, the dynamic model of the TSR is derived using Lagrange method. Then a disturbance observer is designed to estimate the uncertainty based on STW control method. Using the disturbance observer, a controller is designed, and the performance is compared with the dynamic inverse controller which turns out that the proposed controller performs better. Numerical simulation validates the feasibility of the proposed controller on the position and attitude tracking of the TSR.