WorldWideScience

Sample records for testing manual itm

  1. ITM oxygen for gasification

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, P.A.; Foster, E.P. [Air Products and Chemicals Inc., Toronto, ON (Canada); Gunardson, H.H. [Air Products Canada Ltd., Mississauga, ON (Canada)

    2005-11-01

    This paper described a newly developed air separation technology called Ionic Transport Membrane (ITM), which reduces the overall cost of the gasification process. The technology is well suited for advanced energy conversion processes such as integrated gasification combined cycle (IGCC) that require oxygen and use heavy carbonaceous feedstocks such as residual oils, bitumens, coke and coal. It is also well suited for traditional industrial applications for oxygen and distributed power. Air Products Canada Limited developed the ceramic membrane air separation technology that can reduce the cost of pure oxygen by more than 30 per cent. The separation technology achieves a capital cost reduction of 30 per cent and an energy reduction of 35 per cent over conventional cryogenic air separation. ITM is an electrochemical process that integrates well with the gasification process and an IGCC option for producing electricity from the waste heat generated from gasification. This paper described the integration of ITM technology with both the gasification and IGCC processes and showed the attractive economics of ITM. 6 refs., 2 tabs., 6 figs.

  2. Performance of the future MOMA GC-ITMS instrument

    Science.gov (United States)

    Grand, Noel; Buch, Arnaud; Veronica, Pinnick; Szopa, Cyril; Danell, Ryan; Van Amerom, Friso H. W.; Glavin, Daniel P.; Freissinet, Caroline; Arevalo, Ricardo; Stalport, Fabien; Getty, Stephanie; Coll, Patrice; Steinninger, Harald; Brinckerhoff, William; Mahaffy, Paul; Goesmann, Fred; Raulin, F.; Goetz, Walter; MOMA Team

    2016-10-01

    The Mars Organic Molecule Analyzer (MOMA) experiment aboard the future ExoMars mission will be the continuation of the SAM expirement aboard the Curiosity rover, with the search for the organic composition of the Mars surface. With ExoMars the sample will be extracted as deep as 2 meters below the martian surface to minimize effects of radiation and oxidation on organic materials. To analyze the wide range of organic composition (volatile and non-volatiles compounds) of the Martian soil MOMA is composed with an UV laser desorption / ionization (LDI) and a pyrolysis gas chromatography ion trap mass spectrometry (pyr-GC-ITMS). In order to analyze refractory organic compounds and chirality samples which undergo GC-ITMS analysis may be submitted to a derivatization process, consisting of the reaction of the sample components with specific reactants (MTBSTFA [1], DMF-DMA [2] or TMAH [3]).To optimize and test the performance of the GC-ITMS instrument we have performed several coupling tests campaigns between the GC, providing by the French team (LISA, LATMOS, CentraleSupelec), and the MS, providing by the US team (NASA, GSFC). Last campaign has been done with the ETU models which is similar to the flight model and which include the oven and the taping station providing by the German team (MPS).The results obtained demonstrate the current status of the end-to-end performance of the gas chromatography-mass spectrometry mode of operation.

  3. Mariner and the ITm Superfamily of Transposons.

    Science.gov (United States)

    Tellier, Michael; Bouuaert, Corentin Claeys; Chalmers, Ronald

    2015-04-01

    The IS630-Tc1-mariner (ITm) family of transposons is one of the most widespread in nature. The phylogenetic distribution of its members shows that they do not persist for long in a given lineage, but rely on frequent horizontal transfer to new hosts. Although they are primarily selfish genomic-parasites, ITm transposons contribute to the evolution of their hosts because they generate variation and contribute protein domains and regulatory regions. Here we review the molecular mechanism of ITm transposition and its regulation. We focus mostly on the mariner elements, which are understood in the greatest detail owing to in vitro reconstitution and structural analysis. Nevertheless, the most important characteristics are probably shared across the grouping. Members of the ITm family are mobilized by a cut-and-paste mechanism and integrate at 5'-TA dinucleotide target sites. The elements encode a single transposase protein with an N-terminal DNA-binding domain and a C-terminal catalytic domain. The phosphoryl-transferase reactions during the DNA-strand breaking and joining reactions are performed by the two metal-ion mechanism. The metal ions are coordinated by three or four acidic amino acid residues located within an RNase H-like structural fold. Although all of the strand breaking and joining events at a given transposon end are performed by a single molecule of transposase, the reaction is coordinated by close communication between transpososome components. During transpososome assembly, transposase dimers compete for free transposon ends. This helps to protect the host by dampening an otherwise exponential increase in the rate of transposition as the copy number increases.

  4. Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Fogash, Kevin [Air Products and Chemicals, Inc., Allentown, PA (United States)

    2015-12-15

    Air Products carried out a scope of work under DOE Award No. DE-FE0012065 “Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications” with subcontractors Ceramatec, Penn State, and WorleyParsons. The scope of work under this award was aimed at furthering the development of the Ion Transport Membrane (ITM) Oxygen production process toward a demonstration-scale facility known as the Oxygen Development Facility (ODF). Specific activities will help to enable design and construction of the ODF through advancement of a number of challenging technical elements that are required to manage risk in the initial deployment of ITM technology. Major objectives of the work included developing ITM Oxygen ceramic membrane materials with improved performance and reliability, optimizing ceramic module geometry and fabrication methods, testing module performance, trialing the improved fabrication process at commercial scale in the Ceramic Membrane Module Fabrication Facility (CerFab), and advancing engineering development of the ITM oxygen production process, including vessel design and contaminant control measures to prepare for deployment of the ODF. The comprehensive report that follows details the team’s work, which includes several notable accomplishments: 1) compressive creep, a likely limiter of ceramic module lifetime in service, was demonstrated to be retarded by an order of magnitude by changes in material formulation, module joining dimensions, and internal wafer geometry; 2) two promising new materials were shown to be superior to the incumbent ITM material in a key material parameter related to oxygen flux; 3) module degradation mechanisms were identified following operation in large pilot-scale equipment; 4) options for utilizing ITM in a coal-to-liquids (CTL) facility to enable liquids production with carbon capture were identified and studied; and 5) the benefits of potential improvements to the technology

  5. Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Fogash, Kevin [Air Products and Chemicals, Inc., Allentown, PA (United States)

    2017-05-17

    Air Products carried out a scope of work under DOE Award No. DE-FE0012065 “Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications” with subcontractors Ceramatec, Penn State, and WorleyParsons. The scope of work under this award was aimed at furthering the development of the Ion Transport Membrane (ITM) Oxygen production process toward a demonstration-scale facility known as the Oxygen Development Facility (ODF). Specific activities will help to enable design and construction of the ODF through advancement of a number of challenging technical elements that are required to manage risk in the initial deployment of ITM technology. Major objectives of the work included developing ITM Oxygen ceramic membrane materials with improved performance and reliability, optimizing ceramic module geometry and fabrication methods, testing module performance, trialing the improved fabrication process at commercial scale in the Ceramic Membrane Module Fabrication Facility (CerFab), and advancing engineering development of the ITM oxygen production process, including vessel design and contaminant control measures to prepare for deployment of the ODF. The comprehensive report that follows details the team’s work, which includes several notable accomplishments: 1) compressive creep, a likely limiter of ceramic module lifetime in service, was demonstrated to be retarded by an order of magnitude by changes in material formulation, module joining dimensions, and internal wafer geometry; 2) two promising new materials were shown to be superior to the incumbent ITM material in a key material parameter related to oxygen flux; 3) module degradation mechanisms were identified following operation in large pilot-scale equipment; 4) options for utilizing ITM in a coal-to-liquids (CTL) facility to enable liquids production with carbon capture were identified and studied; and 5) the benefits of potential improvements to the technology

  6. Development of ITM oxygen technology for integration in IGCC and other advanced power generation

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Phillip A. [Air Products And Chemicals, Inc., Allentown, PA (United States)

    2015-03-31

    Ion Transport Membrane (ITM) technology is based on the oxygen-ion-conducting properties of certain mixed-metal oxide ceramic materials that can separate oxygen from an oxygen-containing gas, such as air, under a suitable driving force. The “ITM Oxygen” air separation system that results from the use of such ceramic membranes produces a hot, pure oxygen stream and a hot, pressurized, oxygen-depleted stream from which significant amounts of energy can be extracted. Accordingly, the technology integrates well with other high-temperature processes, including power generation. Air Products and Chemicals, Inc., the Recipient, in conjunction with a dozen subcontractors, developed ITM Oxygen technology under this five-phase Cooperative Agreement from the laboratory bench scale to implementation in a pilot plant capable of producing power and 100 tons per day (TPD) of purified oxygen. A commercial-scale membrane module manufacturing facility (the “CerFab”), sized to support a conceptual 2000 TPD ITM Oxygen Development Facility (ODF), was also established and operated under this Agreement. In the course of this work, the team developed prototype ceramic production processes and a robust planar ceramic membrane architecture based on a novel ceramic compound capable of high oxygen fluxes. The concept and feasibility of the technology was thoroughly established through laboratory pilot-scale operations testing commercial-scale membrane modules run under industrial operating conditions with compelling lifetime and reliability performance that supported further scale-up. Auxiliary systems, including contaminant mitigation, process controls, heat exchange, turbo-machinery, combustion, and membrane pressure vessels were extensively investigated and developed. The Recipient and subcontractors developed efficient process cycles that co-produce oxygen and power based on compact, low-cost ITMs. Process economics assessments show significant benefits relative to state

  7. The European Integrated Tokamak Modelling (ITM) effort: achievements and first physics results

    International Nuclear Information System (INIS)

    Falchetto, G.L.; Nardon, E.; Artaud, J.F.; Basiuk, V.; Huynh, Ph.; Imbeaux, F.; Coster, D.; Scott, B.D.; Coelho, R.; Alves, L.L.; Bizarro, João P.S.; Ferreira, J.; Figueiredo, A.; Figini, L.; Nowak, S.; Farina, D.; Kalupin, D.; Boulbe, C.; Faugeras, B.; Dinklage, A.

    2014-01-01

    A selection of achievements and first physics results are presented of the European Integrated Tokamak Modelling Task Force (EFDA ITM-TF) simulation framework, which aims to provide a standardized platform and an integrated modelling suite of validated numerical codes for the simulation and prediction of a complete plasma discharge of an arbitrary tokamak. The framework developed by the ITM-TF, based on a generic data structure including both simulated and experimental data, allows for the development of sophisticated integrated simulations (workflows) for physics application. The equilibrium reconstruction and linear magnetohydrodynamic (MHD) stability simulation chain was applied, in particular, to the analysis of the edge MHD stability of ASDEX Upgrade type-I ELMy H-mode discharges and ITER hybrid scenario, demonstrating the stabilizing effect of an increased Shafranov shift on edge modes. Interpretive simulations of a JET hybrid discharge were performed with two electromagnetic turbulence codes within ITM infrastructure showing the signature of trapped-electron assisted ITG turbulence. A successful benchmark among five EC beam/ray-tracing codes was performed in the ITM framework for an ITER inductive scenario for different launching conditions from the equatorial and upper launcher, showing good agreement of the computed absorbed power and driven current. Selected achievements and scientific workflow applications targeting key modelling topics and physics problems are also presented, showing the current status of the ITM-TF modelling suite. (paper)

  8. Test-bed of a real time detection system of L/H and H/L transitions implemented with the ITMS platform

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, M.; Barrera, E.; Gonzalez, J.; Melendez, R. [Grupo de Investigacion en Instrumentacion y Acustica Aplicada - Universidad Politecnica de Madrid (Spain); Vega, J.; Ratta, G.; Gonzalez, S. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); Murari, A. [Consorzio RFX - Associazione EURATOM ENEA per la Fusione, Padova (Italy)

    2009-07-01

    A basic requirement of the data acquisition systems used in long pulse fusion experiments is to detect events of interest in the acquired signals in real time. Developing such applications is usually a complex task, so it is necessary to develop a set of hardware and software tools that simplify their implementation. An example of these tools is the Intelligent Test and Measurement System (ITMS), which offers distributed data acquisition, distribution and real time processing capabilities with advanced, but easy to use, software tools that simplify application development and system setup. This poster presents the application of the ITMS platform to solve the problem of detecting L/H and H/L transitions in real time based on the use of efficient pattern recognition algorithms. The system architecture used to implement this solution and its performance evaluation are discussed. The system consists of the following elements: a) the ITMS, which is used both to implement the data acquisition and real time LH-HL detection, and to simulate the working environment by reproducing real signals obtained from JET database; b) an event detector, developed using advanced pattern recognition algorithms, that will continuously analyze the information of the acquired signals in order to detect the L/H and H/L transitions; and c) a host computer with several software tools developed with LabVIEW, JAVA and JINI to simplify the development of these complex experiments. These tools allow the user to describe data acquisition and processing tasks using state machines defined in SCXML. These state machines become part of the system setup information, so the behaviour of the system can be changed subsequently by simply modifying these state machines. All the events and key detected are stored by the host computer. This document is a poster. (authors)

  9. DEVELOPMENT OF REACTION-DRIVEN IONIC TRANSPORT MEMBRANES (ITMs) TECHNOLOGY: PHASE IV/BUDGET PERIOD 6 “Development of ITM Oxygen Technology for Integration in IGCC and Other Advanced Power Generation Systems”

    Energy Technology Data Exchange (ETDEWEB)

    David, Studer

    2012-03-01

    Air Products and Chemicals, along with development participants and in association with the U.S. Department of Energy, has made substantial progress in developing a novel air separation technology. Unlike conventional cryogenic processes, this method uses high-temperature ceramic membranes to produce high-purity oxygen. The membranes selectively transport oxygen ions with high flux and infinite theoretical selectivity. Reaction-driven ceramic membranes are fabricated from non-porous, multi-component metallic oxides, operate at temperatures typically over 700°C, and have exceptionally high oxygen flux and selectivity. Oxygen from low-pressure air permeates as oxygen ions through the ceramic membrane and is consumed through chemical reactions, thus creating a chemical driving force that pulls oxygen ions across the membrane at high rates. The oxygen reacts with a hydrocarbon fuel in a partial oxidation process to produce a hydrogen and carbon monoxide mixture – synthesis gas. This project expands the partial-oxidation scope of ITM technology beyond natural gas feed and investigates the potential for ITM reaction-driven technology to be used in conjunction with gasification and pyrolysis technologies to provide more economical routes for producing hydrogen and synthesis gas. This report presents an overview of the ITM reaction-driven development effort, including ceramic materials development, fabrication and testing of small-scale ceramic modules, ceramic modeling, and the investigation of gasifier integration schemes

  10. The coupling effect of gas-phase chemistry and surface reactions on oxygen permeation and fuel conversion in ITM reactors

    KAUST Repository

    Hong, Jongsup; Kirchen, Patrick; Ghoniem, Ahmed F.

    2015-01-01

    © 2015 Elsevier B.V. The effect of the coupling between heterogeneous catalytic reactions supported by an ion transport membrane (ITM) and gas-phase chemistry on fuel conversion and oxygen permeation in ITM reactors is examined. In ITM reactors

  11. The integral membrane protein ITM2A, a transcriptional target of PKA-CREB, regulates autophagic flux via interaction with the vacuolar ATPase.

    Science.gov (United States)

    Namkoong, Sim; Lee, Kang Il; Lee, Jin I; Park, Rackhyun; Lee, Eun-Ju; Jang, Ik-Soon; Park, Junsoo

    2015-01-01

    The PKA-CREB signaling pathway is involved in many cellular processes including autophagy. Recent studies demonstrated that PKA-CREB inhibits autophagy in yeast; however, the role of PKA-CREB signaling in mammalian cell autophagy has not been fully characterized. Here, we report that the integral membrane protein ITM2A expression is positively regulated by PKA-CREB signaling and ITM2A expression interferes with autophagic flux by interacting with vacuolar ATPase (v-ATPase). The ITM2A promoter contains a CRE element, and mutation at the CRE consensus site decreases the promoter activity. Forskolin treatment and PKA expression activate the ITM2A promoter confirming that ITM2A expression is dependent on the PKA-CREB pathway. ITM2A expression results in the accumulation of autophagosomes and interferes with autolysosome formation by blocking autophagic flux. We demonstrated that ITM2A physically interacts with v-ATPase and inhibits lysosomal function. These results support the notion that PKA-CREB signaling pathway regulates ITM2A expression, which negatively regulates autophagic flux by interfering with the function of v-ATPase.

  12. Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Phillip

    2014-11-01

    Air Products is carrying out a scope of work under DOE Award No. DE-FE0012065 “Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications.” The Statement of Project Objectives (SOPO) includes a Task 4f in which a Decision Point shall be reached, necessitating a review of Tasks 2-5 with an emphasis on Task 4f. This Topical Report constitutes the Decision Point Application pertaining to Task 4f. The SOPO under DOE Award No. DE-FE0012065 is aimed at furthering the development of the Ion Transport Membrane (ITM) Oxygen production process toward a demonstration scale facility known as the Oxygen Development Facility (ODF). It is anticipated that the completion of the current SOPO will advance the technology significantly along a pathway towards enabling the design and construction of the ODF. Development progress on several fronts is critical before an ODF project can commence; this Topical Report serves as an early update on the progress in critical development areas. Progress was made under all tasks, including Materials Development, Ceramic Processing Development, Engineering Development, and Performance Testing. Under Task 4f, Air Products carried out a cost and performance study in which several process design and cost parameters were varied and assessed with a process model and budgetary costing exercise. The results show that the major variables include ceramic module reliability, ITM operating temperature, module production yield, and heat addition strategy. High-temperature compact heat exchangers are shown to contribute significant cost benefits, while directly firing into the feed stream to an ITM are even a mild improvement on the high-temperature recuperation approach. Based on the findings to-date, Air Products recommends no changes to the content or emphasis in the current SOPO and recommends its completion prior to another formal assessment of these factors.

  13. Technical Manual: 2002 Series GED Tests

    Science.gov (United States)

    Ezzelle, Carol; Setzer, J. Carl

    2009-01-01

    This manual was written to provide technical information regarding the 2002 Series GED (General Educational Development) Tests. Throughout this manual, documentation is provided regarding the development of the GED Tests, data collection activities, as well as reliability and validity evidence. The purpose of this manual is to provide evidence…

  14. NIF ICCS Test Controller for Automated and Manual Testing

    International Nuclear Information System (INIS)

    Zielinski, J S

    2007-01-01

    The National Ignition Facility (NIF) Integrated Computer Control System (ICCS) is a large (1.5 MSLOC), hierarchical, distributed system that controls all aspects of the NIF laser [1]. The ICCS team delivers software updates to the NIF facility throughout the year to support shot operations and commissioning activities. In 2006, there were 48 releases of ICCS: 29 full releases, 19 patches. To ensure the quality of each delivery, thousands of manual and automated tests are performed using the ICCS Test Controller test infrastructure. The TestController system provides test inventory management, test planning, automated test execution and manual test logging, release testing summaries and test results search, all through a web browser interface. Automated tests include command line based frameworks server tests and Graphical User Interface (GUI) based Java tests. Manual tests are presented as a checklist-style web form to be completed by the tester. The results of all tests, automated and manual, are kept in a common repository that provides data to dynamic status reports. As part of the 3-stage ICCS release testing strategy, the TestController system helps plan, evaluate and track the readiness of each release to the NIF facility

  15. Manual for Cyclic Triaxial Test

    DEFF Research Database (Denmark)

    Shajarati, Amir; Sørensen, Kris Wessel; Nielsen, Søren Kjær

    This manual describes the different steps that is included in the procedure for conducting a cyclic triaxial test at the geotechnical Laboratory at Aalborg University. Furthermore it contains a chapter concerning some of the background theory for the static triaxial tests. The cyclic/dynamic tria......This manual describes the different steps that is included in the procedure for conducting a cyclic triaxial test at the geotechnical Laboratory at Aalborg University. Furthermore it contains a chapter concerning some of the background theory for the static triaxial tests. The cyclic...

  16. The coupling effect of gas-phase chemistry and surface reactions on oxygen permeation and fuel conversion in ITM reactors

    KAUST Repository

    Hong, Jongsup

    2015-08-01

    © 2015 Elsevier B.V. The effect of the coupling between heterogeneous catalytic reactions supported by an ion transport membrane (ITM) and gas-phase chemistry on fuel conversion and oxygen permeation in ITM reactors is examined. In ITM reactors, thermochemical reactions take place in the gas-phase and on the membrane surface, both of which interact with oxygen permeation. However, this coupling between gas-phase and surface chemistry has not been examined in detail. In this study, a parametric analysis using numerical simulations is conducted to investigate this coupling and its impact on fuel conversion and oxygen permeation rates. A thermochemical model that incorporates heterogeneous chemistry on the membrane surface and detailed chemical kinetics in the gas-phase is used. Results show that fuel conversion and oxygen permeation are strongly influenced by the simultaneous action of both chemistries. It is shown that the coupling somewhat suppresses the gas-phase kinetics and reduces fuel conversion, both attributed to extensive thermal energy transfer towards the membrane which conducts it to the air side and radiates to the reactor walls. The reaction pathway and products, in the form of syngas and C2 hydrocarbons, are also affected. In addition, the operating regimes of ITM reactors in which heterogeneous- or/and homogeneous-phase reactions predominantly contribute to fuel conversion and oxygen permeation are elucidated.

  17. SNL Abuse Testing Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Orendorff, Christopher [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lamb, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Steele, Leigh Anna Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    This report describes recommended abuse testing procedures for rechargeable energy storage systems (RESSs) for electric vehicles. This report serves as a revision to the FreedomCAR Electrical Energy Storage System Abuse Test Manual for Electric and Hybrid Electric Vehicle Applications (SAND2005-3123).

  18. FBR metallic materials test manual (English version)

    International Nuclear Information System (INIS)

    Odaka, Susumu; Kato, Shoichi; Yoshida, Eiichi

    2003-06-01

    For the development of the fast breeder reactor, this manual describes the method of in-air and in-sodium material tests and the method of organization the data. This previous manual has revised in accordance with the revision of Japanese Industrial Standard (JIS) and the conversion to the international unit. The test methods of domestic committees such as the VAMAS (Versailles Project on Advanced Materials and Standards) workshop were also refereed. The material test technologies accumulated in this group until now were also incorporated. This English version was prepared in order to provide more engineers with the FBR metallic materials test manual. (author)

  19. Decision Point 3 of Statement of Project Objectives (SOPO) “Recovery Act: Development of ITM Oxygen Technology for Integration with Advanced Industrial Systems”

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Phillip

    2012-03-01

    specifications and intact 1-TPD modules compromised of advanced architecture components. Equipment and processes required for implementation of the advanced architecture design in the CerFab have been identified and are included in the Task 30 scope of equipment supply. Under Task 29.0, Air Products has developed conceptual ideas for implementation of ITM Oxygen in a 2000 TPD test unit. These concepts are proposed for scale up of the ITM technology to large scale with reduced commercial risk. Under Task 30, Air Products and Ceramatec have collaborated to re-design the CerFab process with the advanced architecture wafer production process as primary, and laid out the new process in the Tooele building; the required process equipment have been specified. The project team updated the project cost and schedule estimates, including all environmental permit schedules. The team also re-assessed project risk and costs for the commissioning and operating phases of the program. Newly projected costs for the CerFab, for which details are provided here as attachments, indicate a savings of approximately $100,000 relative to the original estimate at the time of Phase 5 contract definitization. However, an assessment of risks associated with the equipment, process, and operations of the CerFab indicate that approximately $2.9 million of costs should be expected to address various issues in the project. In addition, $1.6 million of additional spending is expected relative to the original estimate to operate the facility during Task 30.2. Air Products proposes a plan to re-direct funds from Tasks 28, 29, and 31 to Task 30 as necessary to allow the CerFab to meet the Phase 5 program objectives.

  20. National Ignition Facility TestController for automated and manual testing

    Energy Technology Data Exchange (ETDEWEB)

    Zielinski, Jason, E-mail: fishler2@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2012-12-15

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  1. National Ignition Facility TestController for automated and manual testing

    International Nuclear Information System (INIS)

    Zielinski, Jason

    2012-01-01

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  2. Softball for Boys and Girls. Skills Test Manual.

    Science.gov (United States)

    Rikli, Roberta E., Ed.

    The first section of this manual provides information on the history of softball and the development of testing for proficiency in the game. The tests in the manual cover batting, fielding ground balls, overhand throwing, and baserunning. Test norms are listed for males and females at each grade level. A review is included of proper techniques and…

  3. An Approach to Analyzing Correlation between Songs/Artists Using iTMS Playlists

    OpenAIRE

    Dou, Yufeng; Ito, Eisuke; Ikeda, Daisuke; Hirokawa, Sachio

    2005-01-01

    Digital audio devices have been changing music entertainment environment. Those devices are bundled with music jukebox software, such as Apple’s iTunes, Sony’s CONNECT player. Jukebox software not only enables us to recode, play, search, purchase music on PC, but also to manage playlist. Anybody can make his/her own playlists, and play music according to the list. In this paper, we focus on iTMS (iTunse Music Stroe) playlists and use them as the data minig resources for a music recommendation...

  4. Manual on laboratory testing for uranium ore processing

    International Nuclear Information System (INIS)

    1990-01-01

    Laboratory testing of uranium ores is an essential step in the economic evaluation of uranium occurrences and in the development of a project for the production of uranium concentrates. Although these tests represent only a small proportion of the total cost of a project, their proper planning, execution and interpretation are of crucial importance. The main purposes of this manual are to discuss the objectives of metallurgical laboratory ore testing, to show the specific role of these tests in the development of a project, and to provide practical instructions for performing the tests and for interpreting their results. Guidelines on the design of a metallurgical laboratory, on the equipment required to perform the tests and on laboratory safety are also given. This manual is part of a series of Technical Reports on uranium ore processing being prepared by the IAEA's Division of Nuclear Fuel Cycle and Waste Management. A report on the Significance of Mineralogy in the Development of Flowsheets for Processing Uranium Ores (Technical Reports Series No. 196, 1980) and an instruction manual on Methods for the Estimation of Uranium Ore Reserves (No. 255, 1985) have already been published. 17 refs, 40 figs, 17 tabs

  5. Manual for Scoring the Test of Directed Imagination.

    Science.gov (United States)

    Veldman, Donald J.; And Others

    A scoring manual for the Directed Imagination Test, a projective technique wherein the subject is instructed to write four fictional stories (four minutes are allowed for each) about teachers and their experiences, is presented. The manual provides detailed instructions for rating each story by fifteen dimensions relevant to teacher education…

  6. İşitme Engelli Çocukların Konuşmalarının Anlaşılabilirliğini Etkileyen Faktörler

    Directory of Open Access Journals (Sweden)

    Zehra Pınar Çeliker

    2005-01-01

    Full Text Available İşitme engeli sözel becerilerin kazanımında önemli güçlüklere neden olmaktadır. Dil ve konuşma gelişimi önemli ölçüde işitmeye dayalı olduğundan, işitme engelli çocukların bu becerilerin ediniminde büyük bir dezavantaja sahip oldukları gözlenmektedir. Gerçekleştirilen pek çok araştırma işitme engellilerin konuşma anlaşılabilirliğinin çok düşük olduğunu göstermektedir. Bu araştırmada, işitme engellilerin konuşmalarının anlaşılabilirliğini etkileyebilecek faktörlerden işitme kaybı derecesi (dB, süre (konuşma hızı, artikülasyon (seslerin doğru üretimi ve cümle vurgusu gibi faktörler arasındaki ilişki incelenmiştir. Araştırma grubu, işitme kayıpları 75dB ile 118dB arasında değişen ve rasgele seçilmiş 17 öğrenciden oluşmuştur. Önceden hazırlanmış cümleleri okuyan öğrencilerden alınan ses kayıtları 19 kişiden oluşan bir jüriye dinletilerek anlaşılabilirlikleri 5’li bir derecelendirme ölçeği üzerinden değerlendirilmiştir. Sözü geçen faktörler içinde anlaşılabilirliği en fazla etkileyen faktörün artikülasyon becerileri olduğu ve bunu işitme kaybının izlediği görülmüştür. Hearing impairment presents considerable problems in the acqusition of verbal skills. Children with hearing impairement are at a disadvantage when developing speech and language because development of those skills relies mostly on hearing. Studies reveal that speech intelligibility of the hearing impaired is low. This study investigated the relationship between speech intelligibility and factors such as degree of hearing loss, speech rate, articulation and sentence stress, that are likely to influence it in children with hearing impairment. The study group consisted of 9-14 yearold 17 school children with hearing losses between 75 and 118 dB. The children were asked to read pre-prepared lists of sentences and then were rated by a jury of 19 on a 5-degree scale of

  7. Sierra/SolidMechanics 4.48 Verification Tests Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Plews, Julia A.; Crane, Nathan K; de Frias, Gabriel Jose; Le, San; Littlewood, David John; Merewether, Mark Thomas; Mosby, Matthew David; Pierson, Kendall H.; Porter, Vicki L.; Shelton, Timothy; Thomas, Jesse David; Tupek, Michael R.; Veilleux, Michael; Xavier, Patrick G.

    2018-03-01

    Presented in this document is a small portion of the tests that exist in the Sierra / SolidMechanics (Sierra / SM) verification test suite. Most of these tests are run nightly with the Sierra / SM code suite, and the results of the test are checked versus the correct analytical result. For each of the tests presented in this document, the test setup, a description of the analytic solution, and comparison of the Sierra / SM code results to the analytic solution is provided. Mesh convergence is also checked on a nightly basis for several of these tests. This document can be used to confirm that a given code capability is verified or referenced as a compilation of example problems. Additional example problems are provided in the Sierra / SM Example Problems Manual. Note, many other verification tests exist in the Sierra / SM test suite, but have not yet been included in this manual.

  8. Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Lee Kenneth [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-03-01

    This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.

  9. Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles

    International Nuclear Information System (INIS)

    Walker, Lee Kenneth

    2017-01-01

    This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.

  10. Manual dexterity aptitude testing: a soap carving study.

    Science.gov (United States)

    Tang, Christopher G; Hilsinger, Raymond L; Cruz, Raul M; Schloegel, Luke J; Byl, Fred M; Rasgon, Barry M

    2014-03-01

    Currently there are few validated metrics for predicting surgical skill among otolaryngology residency applicants. To determine whether manual dexterity aptitude testing in the form of soap carving during otolaryngology residency interviews at Kaiser Permanente Medical Center Oakland predicts surgical skill at the time of graduation from otolaryngology residency programs. This study was conducted to determine how applicants with the best and worst soap carvings compared at the time of graduation with respect to various metrics including visuospatial ability and manual dexterity. Over the last 25 years, applicants to the residency program at Kaiser Permanente Oakland were required to carve soap during their residency interview. The 3 best and 3 worst soap carvings from 1990 through 2006 were determined. Of the individuals who carved those soaps, 62 qualified for the study and matriculated into otolaryngology residency programs. Surveys were sent to the 62 individuals' residency programs to evaluate those individuals on a 5-point Likert scale in various categories as well as to rank those individuals as being in the top 50% or bottom 50% of their graduating class. All else being equal, we hypothesized that applicants who had the manual dexterity and visuospatial skills to accurately carve a bar of soap would more likely possess the skills necessary to become a good surgeon. There was no difference between individuals with the best soap carvings and those with the worst soap carvings in all categories: cognitive knowledge, visuospatial ability, manual dexterity, decision making, and overall score (P > .10 for all categories). There was a 95% response rate, with 35 of 37 residency programs responding and 59 of 62 surveys returned. Manual dexterity aptitude testing in the form of soap carving does not appear to correlate with surgical skill at the time of graduation. Further studies need to be conducted to determine the role of manual dexterity and visuospatial

  11. Training manuals for nondestructive testing using magnetic particles

    Science.gov (United States)

    1968-01-01

    Training manuals containing the fundamentals of nondestructive testing using magnetic particle as detection media are used by metal parts inspectors and quality assurance specialists. Magnetic particle testing involves magnetization of the test specimen, application of the magnetic particle and interpretation of the patterns formed.

  12. Handbook for Classroom Testing in Peace Corps Language Programs. Manual T0068.

    Science.gov (United States)

    Anderson, Neil J.

    This manual provides instructors in Peace Corps language training programs with information about two kinds of classroom testing: formative, ongoing testing and summative testing that occurs at the end of an instructional period. The first of the manual's four chapters on the purposes of language testing, discusses language testing within a…

  13. Controlatron Neutron Tube Test Suite Software Manual - Operation Manual (V2.2)

    CERN Document Server

    Noel, W P; Hertrich, R J; Martinez, M L; Wallace, D L

    2002-01-01

    The Controlatron Software Suite is a custom built application to perform automated testing of Controlatron neutron tubes. The software package was designed to allowing users to design tests and to run a series of test suites on a tube. The data is output to ASCII files of a pre-defined format for data analysis and viewing with the Controlatron Data Viewer Application. This manual discusses the operation of the Controlatron Test Suite Software and a brief discussion of state machine theory, as state machine is the functional basis of the software.

  14. İşitme Engelli Çocukların Konuşma Edinimi Eğitiminde Dinleme Becerilerinin Önemi

    Directory of Open Access Journals (Sweden)

    M. Cem GİRGİN

    2006-01-01

    Full Text Available Konuşma kabaca, konuşma organlarının düzenli devinimleri sonucu üretilen, anlamlı organize ses dizgeleri olarak tanımlanabilir. Dinleme ise çevreden duyulan sesleri tanıma ve özellikle konuşma seslerinin anlamlandırılmasıdır. Konuşma, insana özgü iletişim biçimleri içinde en çok kullanılan yöntemlerden biridir. Bunun yanı sıra dinleme bebeklerin anadillerini ve onun konuşma boyutunun ediniminde önemli rol oynamaktadır. Bebekler doğdukları andan itibaren çevrelerindeki sesleri algılamaya ve konuşma seslerini ayırt edebilmeye programlanmışlardır. Ancak karmaşık konuşma seslerini ve dilin kurallarını sorunsuz edinebilmeleri için dinleme becerilerinin de etkin bir biçimde gelişmesi gerekmektedir. Günümüz teknolojisi, işitme kalıntısının doğru kullanımı ve doğru eğitim yaşantıları sağlanması sonucu, işitme engelli çocukların da işiten çocuklara benzer bir biçimde anadillerini edinmelerine yardımcı olan işitme araçları geliştirmiştir. Ancak dil edinimini ve bilgi dağarcıklarını geliştirebilmek için, işiten çocuklarda bile önem taşıyan dinleme ve konuşma etkinlikleri, işitme engelli çocuklar için ise hayati bir önem taşımaktadır. Bu çalışmada dinleme becerilerinin konuşma ve dil edinimine olan önemli katkıları, bilgi edinmedeki önemi üzerinde durularak dinleme ve konuşma becerilerinin özellikle işitme engelli çocuklara kazandırılmasını kolaylaştıracak etkinlikler tartışılacaktır. Speech can be simply defined as the meaningful organization of sound sequences produced as the result of synchronized movements of speech organs. Listening can be defined as the recognition of sound heard around us and especially making sense of speech sounds. Speech is one of the most common communication tools peculiar to human beings. Speech and listening plays an important role in the acquisition of mother tongue by babies. Babies are programmed to sense

  15. Instrumentation and test gear circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Instrumentation and Test Gear Circuits Manual provides diagrams, graphs, tables, and discussions of several types of practical circuits. The practical circuits covered in this book include attenuators, bridges, scope trace doublers, timebases, and digital frequency meters. Chapter 1 discusses the basic instrumentation and test gear principles. Chapter 2 deals with the design of passive attenuators, and Chapter 3 with passive and active filter circuits. The subsequent chapters tackle 'bridge' circuits, analogue and digital metering techniques and circuitry, signal and waveform generation, and p

  16. Nevada Test Site Radiological Control Manual, Revision 1

    International Nuclear Information System (INIS)

    2010-01-01

    This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 0 issued in October 2009. Brief Description of Revision: A minor revision to correct oversights made during revision to incorporate the 10 CFR 835 Update; and for use as a reference document for Tenant Organization Radiological Protection Programs. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. The NTS is located in Nye County, Nevada. The NTS is located approximately 105 kilometers (65 miles) northwest of Las Vegas. It is a remote facility that covers approximately 3,500 square kilometers (1,375 square miles) of land. The dimensions of the NTS vary from 46 to 56 kilometers (28 to 35 miles) in width (eastern to western border) and from 64 to 88 kilometers (40 to 55 miles) in length (northern to southern border). The NTS is surrounded to the west, north, and east by additional thousands of acres of land withdrawn from the public domain for use as a protected wildlife range and as a military gunnery range. These public exclusion areas comprise the Nellis Air Force Range complex, previously designated as the Nellis Air Force Base Bombing and Gunnery Range, and the Tonopah Test Range. These two areas provide a buffer zone between the test areas and public lands administered by the Federal Bureau of Land

  17. TRENDS: A flight test relational database user's guide and reference manual

    Science.gov (United States)

    Bondi, M. J.; Bjorkman, W. S.; Cross, J. L.

    1994-01-01

    This report is designed to be a user's guide and reference manual for users intending to access rotocraft test data via TRENDS, the relational database system which was developed as a tool for the aeronautical engineer with no programming background. This report has been written to assist novice and experienced TRENDS users. TRENDS is a complete system for retrieving, searching, and analyzing both numerical and narrative data, and for displaying time history and statistical data in graphical and numerical formats. This manual provides a 'guided tour' and a 'user's guide' for the new and intermediate-skilled users. Examples for the use of each menu item within TRENDS is provided in the Menu Reference section of the manual, including full coverage for TIMEHIST, one of the key tools. This manual is written around the XV-15 Tilt Rotor database, but does include an appendix on the UH-60 Blackhawk database. This user's guide and reference manual establishes a referrable source for the research community and augments NASA TM-101025, TRENDS: The Aeronautical Post-Test, Database Management System, Jan. 1990, written by the same authors.

  18. A narrative review of manual muscle testing and implications for muscle testing research.

    Science.gov (United States)

    Conable, Katharine M; Rosner, Anthony L

    2011-09-01

    Manual muscle testing (MMT) is used for a variety of purposes in health care by medical, osteopathic, chiropractic, physical therapy, rehabilitation, and athletic training professionals. The purpose of this study is to provide a narrative review of variations in techniques, durations, and forces used in MMT putting applied kinesiology (AK) muscle testing in context and highlighting aspects of muscle testing important to report in MMT research. PubMed, the Collected Papers of the International College of Applied Kinesiology-USA, and related texts were searched on the subjects of MMT, maximum voluntary isometric contraction testing, and make/break testing. Force parameters (magnitude, duration, timing of application), testing variations of MMT, and normative data were collected and evaluated. "Break" tests aim to evaluate the muscle's ability to resist a gradually increasing pressure and may test different aspects of neuromuscular control than tests against fixed resistances. Applied kinesiologists use submaximal manual break tests and a binary grading scale to test short-term changes in muscle function in response to challenges. Many of the studies reviewed were not consistent in reporting parameters for testing. To increase the chances for replication, studies using MMT should specify parameters of the tests used, such as exact procedures and instrumentation, duration of test, peak force, and timing of application of force. Copyright © 2011 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  19. ACARP Project C10059. ACARP manual of modern coal testing methods. Volume 1: The manual

    Energy Technology Data Exchange (ETDEWEB)

    Sakurovs, R.; Creelman, R.; Pohl, J.; Juniper, L. [CSIRO Energy Technology, Sydney, NSW (Australia)

    2002-07-01

    The Manual summarises the purpose, applicability, and limitations of a range of standard and modern coal testing methods that have potential to assist the coal company technologist to better evaluate coal performance. The first volume sets out the Modern Coal Testing Methods in summarised form that can be used as a quick guide to practitioners to assist in selecting the best technique to solve their problems.

  20. The effect of environmental factors on job Performance using manual and mental tests

    Directory of Open Access Journals (Sweden)

    F. Golbabaei

    2014-07-01

    Conclusion: Finding of the present research manifested that increase in noise and heat stress and also reduction in lighting lessen the speed of manual tests and time and accuracy of mathematical calculations. Therefore this result confirm the effects of various environmental factors on individuals’ job performance, in a way that by variation of different environmental factors, time of manual test and time and accuracy of mental tests would be changed.

  1. Numerical investigation of liquid methanol evaporation and oxy-combustion inside a button-cell ITM reactor

    International Nuclear Information System (INIS)

    Nemitallah, Medhat A.; Habib, Mohamed A.

    2017-01-01

    Highlights: • Analysis of liquid methanol evaporation and oxy-combustion in an ITM reactor. • A semi-empirical model is applied after fitting with the available LNO membrane data. • Influences of inlet fuel fraction, inlet gas temperature and inlet sweep flux are studied. • High combustion efficiency is encountered at moderate inlet gas temperatures. • High fuel concentration at low inlet sweep flow resulted in high oxygen flux. - Abstract: A numerical study is conducted to investigate the performance of a button-cell LNO-ITM reactor utilizing the soot-free oxygenated liquid methanol under oxy-combustion condition. The Euler-Lagrange approach is utilized to solve discrete phase model. Taylor analogy breakup (TAB) model is used due to its convenience with the cases of low injection speed. A plain orifice atomizer is used for fuel atomization and CO_2 is used as sweep gas. A semi-empirical oxygen permeation model (ABn model) is validated with the available experimental data and is, then, applied in the present model. Over a wide range of inlet fuel concentrations, the results showed increase in oxygen permeation flux of about five times in cases of reacting conditions as compared to the cases of non-reacting cases. The results showed high oxygen permeation flux at low inlet fuel concentrations due to the improvement in the oxygen to fuel ratio toward the stoichiometric conditions. At inlet gas temperatures of 1223 K, 1123 K, 1023 K and 923 K, the combustion temperature approached 1423 K, 1347 K, 1284 K and 1231 K, respectively, indicating an average combustion efficiency of 43% at moderate inlet gas temperatures. High fuel concentration at low inlet sweep flow resulted in high oxygen flux and high combustion temperature.

  2. Nevada Test Site Radiological Control Manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2010-02-09

    This document supersedes DOE/NV/25946--801, “Nevada Test Site Radiological Control Manual,” Revision 0 issued in October 2009. Brief Description of Revision: A minor revision to correct oversights made during revision to incorporate the 10 CFR 835 Update; and for use as a reference document for Tenant Organization Radiological Protection Programs.

  3. Test re-test reliability and construct validity of the star-track test of manual dexterity

    DEFF Research Database (Denmark)

    Kildebro, Niels; Amirian, Ilda; Gögenur, Ismail

    2015-01-01

    Objectives. We wished to determine test re-test reliability and construct validity of the star-track test of manual dexterity. Design. Test re-test reliability was examined in a controlled study. Construct validity was tested in a blinded randomized crossover study. Setting. The study was performed...... at a university hospital in Denmark. Participants. A total of 11 subjects for test re-test and 20 subjects for the construct validity study were included. All subjects were healthy volunteers. Intervention. The test re-test trial had two measurements with 2 days pause in between. The interventions...... in the construct validity study included baseline measurement, intervention 1: fatigue, intervention 2: stress, and intervention 3: fatigue and stress. There was a 2 day pause between each intervention. Main outcome measure. An integrated measure of completion time and number of errors was used. Results. All...

  4. User's Manual. Vocational Education Readiness Test (VERT). Revised Edition.

    Science.gov (United States)

    Thomas, Edward L.; And Others

    This user's manual provides information suggesting various ways in which educational personnel may wish to utilize the eight modules included in the Vocational Education Readiness Test (VERT). The introductory section presents questions which can be used by school personnel to determine whether or not VERT will be useful in their school system.…

  5. Laboratory rock mechanics testing manual. Public draft

    Energy Technology Data Exchange (ETDEWEB)

    Shuri, F S; Cooper, J D; Hamill, M L

    1981-10-01

    Standardized laboratory rock mechanics testing procedures have been prepared for use in the National Terminal Waste Storage Program. The procedures emphasize equipment performance specifications, documentation and reporting, and Quality Assurance acceptance criteria. Sufficient theoretical background is included to allow the user to perform the necessary data reduction. These procedures incorporate existing standards when possible, otherwise they represent the current state-of-the-art. Maximum flexibility in equipment design has been incorporated to allow use of this manual by existing groups and to encourage future improvements.

  6. Regional Test Center Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burnham, Laurie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    The U.S. DOE Regional Test Center for Solar Technologies program was established to validate photovoltaic (PV) technologies installed in a range of different climates. The program is funded by the Energy Department's SunShot Initiative. The initiative seeks to make solar energy cost competitive with other forms of electricity by the end of the decade. Sandia National Laboratory currently manages four different sites across the country. The National Renewable Energy Laboratory manages a fifth site in Colorado. The entire PV portfolio currently includes 20 industry partners and almost 500 kW of installed systems. The program follows a defined process that outlines tasks, milestones, agreements, and deliverables. The process is broken out into four main parts: 1) planning and design, 2) installation, 3) operations, and 4) decommissioning. This operations manual defines the various elements of each part.

  7. U.S. Department of Energy Vehicle Technologies Program: Battery Test Manual For Plug-In Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Christophersen, Jon P. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Renata M. Arsenault of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).

  8. Demand-side management project for Tenaga Nasional Berhad: Energy efficiency study: Institut Teknologi Mara (ITM) complex. Final report. Export trade information

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    This study, conducted by the California Energy Commission, was funded by the U.S. Trade and Development Agency. The report focuses on energy efficiency and conservation measures at the Institut Teknologi Mara (ITM) Complex for Tenaga Nasional Berhad in Malaysia. The study is divided into the following sections: Preface; (1.0) Executive Summary; (2.0) Facility Background and Site Information; (3.0) Site Energy Use; (4.0) Energy Using Systems; (5.0) On-Site Electricity and Energy Generation; (6.0) Technical Project Summary; Figures, Tables, Appendices.

  9. HVAC system operation manual of IMEF

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun.

    1997-06-01

    This manual is operation procedures of the IMEF(Irradiated Material Examination Facility) HVAC(Heating, Ventilation and Air Conditioning) System. General operation procedures and test method of the IMEF HVAC system are described. The manual is as follows; 1. HVAC system operation manual 2. HVAC system management guide 3. HVAC system maintenance manual 4. HVAC system air velocity and flowrate measurement manual 5. HVAC system HEPA filter leak test manual 6. HVAC system charcoal filter leak test manual 7. HVAC system HEPA and charcoal filter exchange manual. (author). 8 tabs

  10. Fate of iprovalicarb, indoxacarb, and boscalid residues in grapes and wine by GC-ITMS analysis.

    Science.gov (United States)

    Angioni, Alberto; Dedola, Fabrizio; Garau, Vincenzo Luigi; Schirra, Mario; Caboni, Pierluigi

    2011-06-22

    The behavior in field and the transfer from grapes to wine during winemaking of iprovalicarb, indoxacarb, and boscalid was studied. The residue levels found in grapes were far below the MRLs set for grapes in EU, accounting at harvest time 0.81, 0.43, and 4.23 mg/kg for iprovalicarb, indoxacarb, and boscalid, respectively. The residue levels in the samples treated with boscalid may have residual problems (due to an accumulation effect) if repeated field treatments will be performed. Winemaking experiments showed a complete transfer of all pesticide from grapes to the must, while in wine the residues were low or negligible due to the adsorbing effect of lees and pomace. The clarification experiments showed a good removal of pesticide residues from the wine media, for all pesticides. The GC-ITMS method showed good performance with adequate recoveries ranging from 75 to 115%, and good method limits of quantitation (LOQs) and of determination (LODs) far below MRLs.

  11. Antarctic observations at long wavelengths with the IRAIT-ITM Telescope at Dome C

    Science.gov (United States)

    Durand, Gilles A.; Tremblin, Pascal; Minier, Vincent; Reinert, Yann; Leroy dos Santos, Christophe; Rodriguez, Louis; Joffrin, Xavier; Busso, Maurizio; Tosti, Gino; Nucciarelli, Giuliano; Dolci, Mauro; Straniero, Oscar; Valentini, Angelo; Abia, Carlos; Christille, Jean Marc; Doumayrou, Eric; Lortholary, Michel; Charron, Patrice; Lotrus, Paul; Walter, Christian; Ronayette, Samuel; Challita, Zalpha; Fromont, Laurent; Condamin, Mathieu; Kwon, Min Kyong; Tavagnacco, Daniele

    2014-07-01

    We illustrate the status of the international infra-red telescope IRAIT-ITM, a project developed thanks to an Italian- Spanish-French collaboration and now sited at the Dome C Antarctic base. The telescope and its subsystems were installed at DomeC by a team of Italian and French scientists. The 80 cm telescope is placed on a small snow hill next to a laboratory of astronomy. The operations started in January 2013, with the Nasmyth focal planes equipped with the midinfrared camera AMICA for 1.25 to 25 μm and the sub-millimetre camera CAMISTIC for observation of the sky noise at 200 and 350 μm using a bolometer camera. During 2013 the two winter-overs worked mainly on technological duties, learning how to operate the telescope, while temperatures decreased down to -80°C. The cryogenic systems could be operated respectively at 0.25K and 4K at all times, with satisfactory use of the heat from the compressors of the cryocoolers to the warm-up the laboratory through a closed loop glycol system. The lack of tests and reliability in extreme conditions of some components and difficult access to maintenance hampered regular observations below -50°C. Using the lessons of this first winter, the summer team improves the robustness of the failing systems and ease the access to maintenance. The winter 2014 is the first one with programmed observations. Because of power restrictions, the two instruments are used each one at a time by periods of 2 weeks. The Camistic camera continues to observe the stability of the sky at a fixed altitude in chopping mode and performs skydips. The TCS is being upgraded in order to prepare the next summer season with extensive observations of the sun with Camistic.

  12. SHARP User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y. Q. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States); Thomas, J. W. [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay S. [Argonne National Lab. (ANL), Argonne, IL (United States); Rahaman, Ronald O. [Argonne National Lab. (ANL), Argonne, IL (United States); Solberg, Jerome [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-31

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  13. SHARP User Manual

    International Nuclear Information System (INIS)

    Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.; Mahadevan, Vijay S.; Rahaman, Ronald O.; Solberg, Jerome

    2016-01-01

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  14. Manual for operation of the multipurpose thermalhydraulic test facility TOPFLOW (Transient Two Phase Flow Test Facility)

    International Nuclear Information System (INIS)

    Beyer, M.; Carl, H.; Schuetz, H.; Pietruske, H.; Lenk, S.

    2004-07-01

    The Forschungszentrum Rossendorf (FZR) e. V. is constructing a new large-scale test facility, TOPFLOW, for thermalhydraulic single effect tests. The acronym stands for transient two phase flow test facility. It will mainly be used for the investigation of generic and applied steady state and transient two phase flow phenomena and the development and validation of models of computational fluid dynamic (CFD) codes. The manual of the test facility must always be available for the staff in the control room and is restricted condition during operation of personnel and also reconstruction of the facility. (orig./GL)

  15. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    Directory of Open Access Journals (Sweden)

    Dariusz Wroblewski

    2014-01-01

    Full Text Available Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1 manual, with patient response registered with a mouse click, and (2 visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1 minimal systematic differences between measurements taken in visual grasp and manual modes, (2 the average standard deviation of the difference distributions of about 5 dB, and (3 a systematic shift (of 4–6 dB to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients’ acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  16. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    Science.gov (United States)

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  17. ACT Plan: Technical Manual. 2013/2014

    Science.gov (United States)

    ACT, Inc., 2013

    2013-01-01

    This manual contains information about the American College Test (ACT) Plan® program. The principal focus of this manual is to document the Plan program's technical adequacy in light of its intended purposes. This manual supersedes the 2011 edition. The content of this manual responds to requirements of the testing industry as established in the…

  18. Technical manual: operation and equipment instructions for in situ impulse test

    International Nuclear Information System (INIS)

    1979-11-01

    This manual describes the test equipment and procedures for a new field test which determines the shear modulus of a soil deposit at strain levels equivalent to those experienced during actual earthquakes. Results from this test are typically used as input parameters to response analyses for evaluating local soil effects during earthquake shaking. The test employs a cross-hole wave propagation procedure with velocity transducers located in closely spaced adjacent borings. Clear, consistent, and repeatable data in all types of soil and a method of data reduction different from conventional geophysical first arrival techniques are unique aspects of this new test. In addition to describing the principles of the test and data reduction procedures, major discussions of the field procedures are also included. Detailed drilling and testing information is provided both for planning and executing a test program

  19. Effects of operator time pressure and noise on manual ultrasonic testing

    International Nuclear Information System (INIS)

    Enkvist, J.; Edland, A.; Svenson, O.

    2002-01-01

    In earlier studies of manual ultrasonic testing, great variations have been found in operator performance, often attributed to operator fatigue. However, no conclusive findings have been reported. In the present study, twenty operators performed manual ultrasonic inspections of six test-pieces with manufactured flaws. The operators performed the inspections under stress (high arousal - time pressure and noise) and no-stress conditions; one condition the first day and the other the second and last day. According to the Yerkes-Dodson Law there is an optimal arousal level where performance is highest. It was hypothesised that the stress condition led to a level of arousal so high that it would affect the results negatively. However, contrary to the hypotheses it was found that the manipulation increased operator performance. Operators with the stress condition day 1 performed better than the other operators (under the no-stress condition). This was interpreted as the 'stress first' (group 1) operators had established efficient performance patterns the first day - affecting also the second day. Operators beginning with stress condition also tended to be more motivated. It was concluded that operator performance is affected by arousal. (author)

  20. PC based manual and safety logic card test setup for 235 MWe PHWRs

    International Nuclear Information System (INIS)

    Chandgadkar, G.M.; Kohli, A.K.; Agarwal, R.G.; Chandra, Rajesh

    1992-01-01

    Fuel handling controls for 235 MWe PHWR make use of Manual and Logic cards (MLCs) for providing safety interlocks. These cards consist of various type of logic blocks. By connecting these logic blocks all the safety interlocks required for fuel handling controls have been provided. Previously trouble shooting of these cards was done by means of logic probe. Since the method was manual, it was laborious and time consuming. PC based test setup has overcome this drawback and detects the fault at the component level within few seconds. It also gives printout of status of faulty MLC cards. Here motherboard has been designed having slots for insertion of MLC cards. The input/output connection of these cards are coming to two 50 pin FRC connectors. PC communicates through 144 line digital input/output card with MLC card under test. Software is user friendly and outputs suitable input patterns to the card under test and checks for output pattern. It compares this output pattern with compare pattern and detects the fault and displays the symptoms. This system is currently in use at test facility for fuelling machine for 235 MWe PHWR reactor at Refuelling Technology Division, Hall-7. This test setup has been proposed for use at NAPP and future reactors. (author). 4 figs., 1 annexure

  1. Assessment of knee laxity using a robotic testing device: a comparison to the manual clinical knee examination.

    Science.gov (United States)

    Branch, T P; Stinton, S K; Siebold, R; Freedberg, H I; Jacobs, C A; Hutton, W C

    2017-08-01

    The purpose of this study was to collect knee laxity data using a robotic testing device. The data collected were then compared to the results obtained from manual clinical examination. Two human cadavers were studied. A medial collateral ligament (MCL) tear was simulated in the left knee of cadaver 1, and a posterolateral corner (PLC) injury was simulated in the right knee of cadaver 2. Contralateral knees were left intact. Five blinded examiners carried out manual clinical examination on the knees. Laxity grades and a diagnosis were recorded. Using a robotic knee device which can measure knee laxity in three planes of motion: anterior-posterior, internal-external tibia rotation, and varus-valgus, quantitative data were obtained to document tibial motion relative to the femur. One of the five examiners correctly diagnosed the MCL injury. Robotic testing showed a 1.7° larger valgus angle, 3° greater tibial internal rotation, and lower endpoint stiffness (11.1 vs. 24.6 Nm/°) in the MCL-injured knee during varus-valgus testing when compared to the intact knee and 4.9 mm greater medial tibial translation during rotational testing. Two of the five examiners correctly diagnosed the PLC injury, while the other examiners diagnosed an MCL tear. The PLC-injured knee demonstrated 4.1 mm more lateral tibial translation and 2.2 mm more posterior tibial translation during varus-valgus testing when compared to the intact knee. The robotic testing device was able to provide objective numerical data that reflected differences between the injured knees and the uninjured knees in both cadavers. The examiners that performed the manual clinical examination on the cadaver knees proved to be poor at diagnosing the injuries. Robotic testing could act as an adjunct to the manual clinical examination by supplying numbers that could improve diagnosis of knee injury. Level II.

  2. Training Guidelines in Non-Destructive Testing Techniques: Manual for Visual Testing at Level 2

    International Nuclear Information System (INIS)

    2013-01-01

    The International Atomic Energy Agency (IAEA) has been active in the promotion of non-destructive testing (NDT) technology for many decades. The prime reason for this interest has been the need for stringent quality control standards for safe operation of nuclear as well as other industrial installations. The IAEA has successfully executed a number of projects, including technical cooperation projects (national and regional) and coordinated research projects, in which NDT was an important part. Through these projects, a large number of persons have been trained in numerous Member States, leading to the establishment of national certifying bodies responsible for training and certification of NDT personnel. Consequently a state of self-sufficiency in this area of technology has been achieved in many of these States. All along there has been a realization of the need to have well established training guidelines and related books, in order, first, to guide IAEA experts involved in this training programme and, second, to achieve some level of international uniformity and harmonization of training materials and consequent competence of NDT personnel. The syllabuses for training courses have been published in the form of TECDOC publications. The first was IAEA-TECDOC-407 (1987), which contained syllabuses for the five basic NDT methods: liquid penetrant testing, magnetic particle testing, eddy current testing, radiographic testing and ultrasonic testing. To accommodate advancements in NDT technology, later versions of this publication were issued in 1991, 2002 and 2008, with the current version being IAEA-TECDOC- 628/Rev.2 (2008), which includes additional and more advanced NDT methods. The next logical step was to compile textbooks and training manuals in accordance with these syllabuses. Manuals on liquid penetrant, magnetic particle, radiographic, ultrasonic and eddy current testing have already been published in the Training Course Series. These play a vital role in

  3. Examples for simple solutions in using manual ultrasonic testing with partial mechanisation

    International Nuclear Information System (INIS)

    Prestel, W.; Meyer, H.J.; Weiss, M.

    1989-01-01

    Fully automatic ultrasonic testing regarding test technique, manipulation and evaluation can only be used economically if one is either testing large number of parts or if manual testing of safety-related components is impossible because of inaccessibility, e.g.: for primary circuit components of nuclear powerstations. The described examples (multi-layer ceramic condensers, turbine rotors, cast steel components, central holes in forged shafts, weld seams and piston bolts) show that by individually designed and, where necessary, computer-aided part-mechanisation, ultrasonic testing is able to combine high probability of finding faults in the interests of the greatest possible operating safety and the requirement for the description or documentation of the fault suitable for the required case with the necessity for economical testing. (orig./MM) [de

  4. Field and in-situ rock-mechanics testing manual. Technical report

    International Nuclear Information System (INIS)

    Shuri, F.S.; Feves, M.L.; Peterson, G.L.; Foster, K.M.; Kienle, C.F. Jr.

    1981-10-01

    Standardized field and in situ rock mechanics testing procedures have been prepared for use in the National Terminal Waste Storage Program. The procedures emphasize equipment performance specifications, documentation and reporting, and Quality Assurance acceptance criteria. Sufficient theoretical background is included to allow the user to perform the necessary data reduction. These procedures incorporate existing standards when possible, otherwise they represent the current state of the art. Maximum flexibility in equipment design has been incorporated to allow use of this manual by existing groups and to encourage future improvements

  5. Nevada Test Site Radiological Control Manual

    International Nuclear Information System (INIS)

    2009-01-01

    This document supersedes DOE/NV/11718--079, 'NV/YMP Radiological Control Manual,' Revision 5 issued in November 2004. Brief Description of Revision: A complete revision to reflect the recent changes in compliance requirements with 10 CFR 835, and for use as a reference document for Tenant Organization Radiological Protection Programs.

  6. Initial Development of a Modified Trail Making Test for Individuals with Impaired Manual Functioning.

    Science.gov (United States)

    Rane, Shruti; Caroselli, Jerome Silvio; Dickinson, Mercedes; Tran, Kim; Kuang, Fanny; Hiscock, Merrill

    2016-01-01

    The Trail Making Test (TMT), a widely used neuropsychological test, is highly effective in detecting brain damage. A shortcoming of the test is that it requires drawing lines and thus is impractical for use with persons suffering manual impairment. The 3 studies described herein were designed to describe and evaluate a nonmanual Trail Making Test (NMTMT) that would be suitable for use with manually impaired individuals. The NMTMT utilizes color to permit oral reporting of the stimuli constituting a series of numbers (Part A) or alternating series of numbers and letters (Part B). The studies, which involved a total of 200 university students, indicate that the standard TMT and the NMTMT are moderately related to each other and have similar patterns of association and nonassociation with other neuropsychological measures. Participants with scores falling near the bottom of the NMTMT distribution have a high probability of scoring at least 1 standard deviation below the mean of the TMT distribution for Part B. The clinically important relationship of Part A to Part B seems to be retained in the NMTMT. It is concluded that the NMTMT shows promise as a substitute for the TMT when the TMT cannot be used.

  7. ACER Tests of Basic Skills: Aspects of Literacy, Aspects of Numercy. Teacher's Manual. Blue Series 6.

    Science.gov (United States)

    Lokan, Jan; And Others

    Developed for the Basic Skills Testing Program (BSTP) in New South Wales, Australia, this teacher's manual describes the ACER (Australian Council for Educational Research) Tests of Basic Skills. The two tests in this series, Aspects of Literacy and Aspects of Numeracy, were administered statewide by government school classroom teachers in August,…

  8. ACER Tests of Basic Skills: Aspects of Literacy, Aspects of Numeracy. Teacher's Manual. Green Series 6.

    Science.gov (United States)

    Lokan, Jan; And Others

    Developed for the Basic Skills Testing Program (BSTP) in New South Wales, Australia, this teacher's manual describes the Green Series 6 of the ACER (Australian Council for Educational Research) Tests of Basic Skills. The two tests in this series, Aspects of Literacy and Aspects of Numeracy, were administered statewide by government school…

  9. ACER Tests of Basic Skills: Aspects of Literacy, Aspects of Numeracy. Teacher's Manual. Blue Series 3.

    Science.gov (United States)

    Lokan, Jan; And Others

    Developed for the Basic Skills Testing Program (BSTP) in New South Wales, Australia, this teacher's manual describes the Blue Series 3 of the ACER (Australian Council for Educational Research) Tests of Basic Skills. The two tests in the series, Aspects of Literacy and Aspects of Numeracy, were administered statewide by government school classroom…

  10. ACER Tests of Basic Skills: Aspects of Literacy, Aspects of Numeracy. Teacher's Manual. Green Series 3.

    Science.gov (United States)

    Lokan, Jan; And Others

    Developed for the Basic Skills Testing Program (BSTP) in New South Wales, Australia, this teacher's manual describes the Green Series 3 of the ACER (Australian Council for Educational Research) Tests of Basic Skills. The two tests in this series, Aspects of Literacy and Aspects of Numeracy, were administered statewide by government school…

  11. Nevada Test Site Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council - Nevada Test Site

    2009-10-01

    This document supersedes DOE/NV/11718--079, “NV/YMP Radiological Control Manual,” Revision 5 issued in November 2004. Brief Description of Revision: A complete revision to reflect the recent changes in compliance requirements with 10 CFR 835, and for use as a reference document for Tenant Organization Radiological Protection Programs.

  12. Effects of age and sex on the results of an ankle plantar-flexor manual muscle test.

    Science.gov (United States)

    Jan, Mei-Hwa; Chai, Huei-Ming; Lin, Yeong-Fwu; Lin, Janice Chien-Ho; Tsai, Li-Ying; Ou, Yu-Chih; Lin, Da-Hon

    2005-10-01

    The ability to perform 20 or more one-leg heel-rises is considered a "normal" grade for muscle strength (force-generating capacity of muscle) of the ankle plantar flexors, regardless of age and sex. Because muscle strength is closely related to age and sex, the "normal" test criterion was re-evaluated in different groups categorized by age and sex. One hundred eighty sedentary volunteers (21-80 years of age) without lower-limb lesions performed as many repetitions of one-leg heel-rise as possible. Lunsford and Perry criteria were used to determine completion of the test. The age and sex of the participants influenced the maximal repetitions of heel-rise, and the repetitions decreased with age and in female subjects. The muscle strength of the ankle plantar flexors, as measured by manual muscle testing, varied with age and sex. Clinicians should consider the variances of age and sex when they perform manual muscle testing of the ankle plantar flexors.

  13. ACARP Project C10059. ACARP manual of modern coal testing methods. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Sakurovs, R.; Creelman, R.; Pohl, J.; Juniper, L. [CSIRO Energy Technology, Sydney, NSW (Australia)

    2002-07-01

    The Manual summarises the purpose, applicability, and limitations of a range of standard and modern coal testing methods that have potential to assist the coal company technologist to better evaluate coal performance. It is presented in two volumes. This second volume provides more detailed information regarding the methods discussed in Volume 1.

  14. X-ray microtomography (microCT of male genitalia of Nothybus kuznetsovorum (Nothybidae and Cothornobata sp. (Micropezidae

    Directory of Open Access Journals (Sweden)

    Tatiana V. Galinskaya

    2018-03-01

    Full Text Available The results of manual dissection of the musculature of the male genitalia in Nothybus kuznetsovorum are fully confirmed by the modern methods of Micro-CT. A comparative analysis of Neria commutata and Cothornobata sp. shows that an increase in the flexion in the genitalia of males and the displacement of syntergosternite VII to the ventral side in Cothornobata sp. caused the disappearance of the muscles ITM6–7r and ITM7–8r. In addition, this increase in flexion apparently caused the fusion of the M18 muscles into one bundle. The muscle ISM5-6c goes on to moving the second segment of the forcipate appendages of sternite V.

  15. The field-testing of a novel integrated mapping protocol for neglected tropical diseases.

    Directory of Open Access Journals (Sweden)

    Sonia Pelletreau

    2011-11-01

    Full Text Available BACKGROUND: Vertical control and elimination programs focused on specific neglected tropical diseases (NTDs can achieve notable success by reducing the prevalence and intensity of infection. However, many NTD-endemic countries have not been able to launch or scale-up programs because they lack the necessary baseline data for planning and advocacy. Each NTD program has its own mapping guidelines to collect missing data. Where geographic overlap among NTDs exists, an integrated mapping approach could result in significant resource savings. We developed and field-tested an innovative integrated NTD mapping protocol (Integrated Threshold Mapping (ITM Methodology for lymphatic filariasis (LF, trachoma, schistosomiasis and soil-transmitted helminths (STH. METHODOLOGY/PRINCIPAL FINDINGS: The protocol is designed to be resource-efficient, and its specific purpose is to determine whether a threshold to trigger public health interventions in an implementation unit has been attained. The protocol relies on World Health Organization (WHO recommended indicators in the disease-specific age groups. For each disease, the sampling frame was the district, but for schistosomiasis, the sub-district rather than the ecological zone was used. We tested the protocol by comparing it to current WHO mapping methodologies for each of the targeted diseases in one district each in Mali and Senegal. Results were compared in terms of public health intervention, and feasibility, including cost. In this study, the ITM methodology reached the same conclusions as the WHO methodologies regarding the initiation of public health interventions for trachoma, LF and STH, but resulted in more targeted intervention recommendations for schistosomiasis. ITM was practical, feasible and demonstrated an overall cost saving compared with the standard, non-integrated, WHO methodologies. CONCLUSIONS/SIGNIFICANCE: This integrated mapping tool could facilitate the implementation of much

  16. Data collection system. Volume 1, Overview and operators manual; Volume 2, Maintenance manual; Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, R.B.; Bauder, M.E.; Boyer, W.B.; French, R.E.; Isidoro, R.J.; Kaestner, P.C.; Perkins, W.G.

    1993-09-01

    Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).

  17. EML procedures manual

    International Nuclear Information System (INIS)

    Volchok, H.L.; de Planque, G.

    1982-01-01

    This manual contains the procedures that are used currently by the Environmental Measurements Laboratory of the US Department of Energy. In addition a number of analytical methods from other laboratories have been included. These were tested for reliability at the Battelle, Pacific Northwest Laboratory under contract with the Division of Biomedical and Environmental Research of the AEC. These methods are clearly distinguished. The manual is prepared in loose leaf form to facilitate revision of the procedures and inclusion of additional procedures or data sheets. Anyone receiving the manual through EML should receive this additional material automatically. The contents are as follows: (1) general; (2) sampling; (3) field measurements; (4) general analytical chemistry; (5) chemical procedures; (6) data section; (7) specifications

  18. Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes.

    Science.gov (United States)

    Krämer, Irene; Federici, Matteo; Kaiser, Vanessa; Thiesen, Judith

    2016-04-01

    The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5-7 days at room temperature, followed by 2-3 days at 30-35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light

  19. İşitme Engelli Bir Çocuğun Okuma Yazma Becerilerinin Dil Deneyim Yaklaşımı İle Desteklenmesi

    Directory of Open Access Journals (Sweden)

    H. Pelin Karasu

    2015-01-01

    Full Text Available Dil Deneyim Yaklaşımı; dinleme, konuşma, okuma ve yazma becerilerinin bir arada kullanılması ve okuma materyallerinin öğrencilerin deneyimleriyle oluşturulması temeline dayanmaktadır. Bu araştırmanın amacı, işitme engelli bir çocuğun okuma yazma becerilerinin gelişiminin Dil Deneyim Yaklaşımı ile desteklenme sürecinin incelenmesidir. Araştırma, bu amaç doğrultusunda, eylem araştırması şeklinde desenlenmiştir. Araştırmanın katılımcıları; araştırmacı öğretmen, geçerlik komitesi üyeleri, ilkokul 2. sınıfa devam eden işitme engelli bir öğrenci ve sınıf öğretmenidir. Araştırma verileri; araştırmacı günlüğü, belgeler, görüşmeler, uygulama planları, uygulama videoteyp kayıtları ve formel olmayan değerlendirmeler kullanılarak elde edilmiştir. Araştırma bulguları, sürecin iki evrede gerçekleştiğini göstermektedir. Bu evreler; sıralı kartlardaki olayların sözlü ve yazılı dille paylaşılması ile kelime bankası ve sözdizimi etkinliğidir. Araştırma sonuçları; dil deneyim uygulamalarının sözlü dilin gelişmesi için fırsatlar sağladığını, sözel ipuçlarının kullanılmasına, düşüncelerin sözlü ve yazılı dille ifade edilmesine olanak verdiğini, sözcük dağarcığı ve sözdizimine ilişkin ihtiyaçların belirlenmesini sağlayarak öğrencinin düzeyine uygun etkinliklerin hazırlanmasına fırsat sağladığını göstermektedir.Anahtar Sözcükler: Dil deneyim yaklaşımı, okuma yazma becerileri, işitme engelli çocuk Supporting a Hearing Impaired Child’s Literacy Development With Language Experience Approach Abstract Language Experience Approach (LEA emphasizes the synergy among listening, speaking, reading and writing skills and suggests considering learners’ experiences while preparing reading materials. The aim of the current study is to investigate LEA’s supportive role in a hearing impaired child’s literacy development. In

  20. Intra?Target Microdosing ? A Novel Drug Development Approach: Proof of Concept, Safety, and Feasibility Study in Humans

    OpenAIRE

    Burt, T; MacLeod, D; Lee, K; Santoro, A; DeMasi, DK; Hawk, T; Feinglos, M; Rowland, M; Noveck, RJ

    2017-01-01

    Intra-target microdosing (ITM) is a novel drug development approach aimed at increasing the efficiency of first-in-human (FIH) testing of new molecular entities (NMEs). ITM combines intra-target drug delivery and "microdosing," the subpharmacological systemic exposure. We hypothesized that when the target tissue is small (about 1/100th of total body mass), ITM can lead to target therapeutic-level exposure with minimal (microdose) systemic exposure. Each of five healthy male volunteers receive...

  1. Ortaokula devam eden işitme engelli öğrencilerin yazı performanslarının incelenmesi: Örnek grup çalışması

    Directory of Open Access Journals (Sweden)

    Reşat Alatlı

    2017-04-01

    Full Text Available Bu çalışmada, işaret dili ile dikte edilen bir metin incelenerek, işitme engelli öğrencilerin yazma performanslarının belirlenmesi amaçlanmıştır. Araştırmaya 6.,7. ve 8. sınıfa devam eden 10 işitme engelli öğrenci katılmıştır. Araştırmada veri toplama aracı olarak, araştırmacıların hazırladığı, uzman görüşü alınmış ve gündelik hayatta sık kullanılan sözcüklerin yer aldığı 57 kelimeden oluşan bir metin kullanılmıştır. Yazılı metinlerdeki, yazma hataları analiz edilmiştir. Elde edilen yazılı metinlerde harf ve/veya hece atlama (letter and/or morpheme omission, harf ve/veya hece ekleme (addition of letter and/or morpheme, sözcük atlama (word omission, sözcük ekleme (addition of word hataları olduğu görülmüştür. Ayrıca kelimenin yanlış olarak kullanılması ve çekim eki hataları gibi hatalar yaptıkları belirlenmiştir. İşitme engelli öğrencilerin, yazılı anlatım becerilerindeki sınırlılıklarının, günlük yaşam ve akademik beceriler üzerindeki etkisi alanyazın çerçevesinde tartışılmıştır. The purpose of this study is to investigate the writing performance of students with hearing impairment who are attending secondary school, on a text which has been dictated by the sign language. 10 students with hearing impairment, who are at 6th, 7th , and 8th grades, have participated in the study. A text prepared by the researchers which included 57 frequently used words, was dictated by sign language. Writing errors in the text were analyzed qualitatively. According to the results, students with hearing impairment have a number of limitations such as the omission of letters and/or morphemes, the addition of letters and/or morphemes, omission and/or adding words, mistakes on using the words and inflections. Also, it has been concluded within the scope of the information in the field that how these limitations affect academic and daily life skills.

  2. A generic access to shot-based data for European Tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Signoret, J.; Imbeaux, F. [Association EURATOM-CEA, CEA / DSM / Institut de Recherche sur la Fusion par confinement Magnetique, CEA-Cadarache, 13 - ST-Paul-Lez-Durance (France)

    2009-07-01

    The EFDA Integrated Tokamak Modeling Task Force has defined a data structure offering a generic representation of the properties of physics problems and tokamak subsystem characteristics. It gathers the hardware description, modeling results and data measured during experiments, structured in terms of Consistent Physical Objects (CPOs). A generic tool has been developed to retrieve shot-based data from the various European tokamak databases: Exp2ITM. A tokamak specific XML 'mapping file' is used to map the local data formats to the ITM (Integrated Tokamak Modeling) data format. Exp2ITM is then dynamically generated from the ITM data structure and uses generic procedures to import the shot-based data. Successful tests show we have managed to import into the ITM DB experimental data from Jet and Tore-Supra. This document is a poster. (authors)

  3. Manually controlled neutron-activation system

    International Nuclear Information System (INIS)

    Johns, R.A.; Carothers, G.A.

    1982-01-01

    A manually controlled neutron activation system, the Manual Reactor Activation System, was designed and built and has been operating at one of the Savannah River Plant's production reactors. With this system, samples can be irradiated for up to 24 hours and pneumatically transferred to a shielded repository for decay until their activity is low enough for them to be handled at a radiobench. The Manual Reactor Activation System was built to provide neutron activation of solid waste forms for the Alternative Waste Forms Leach Testing Program. Neutron activation of the bulk sample prior to leaching permits sensitive multielement radiometric analyses of the leachates

  4. A study on special test stand of automatic and manual descent control in presence of simulated g-load effect

    Science.gov (United States)

    Glazkov, Yury; Artjuchin, Yury; Astakhov, Alexander; Vas'kov, Alexander; Malyshev, Veniamin; Mitroshin, Edward; Glinsky, Valery; Moiseenko, Vasily; Makovlev, Vyacheslav

    The development of aircraft-type reusable space vehicles (RSV) involves the problem of complete compatibility of automatic, director and manual control. Task decision is complicated, in particular, due to considerable quantitative and qualitative changes of vehicle dynamic characteristics, little stability margins (and even of unstability) of the RSV, and stringent requirements to control accuracy at some flight phases. Besides, during control a pilot is affected by g-loads which hamper motor activity and deteriorate its accuracy, alter the functional status of the visual analyser, and influence higher nervous activity. A study of g-load effects on the control efficiency, especially in manual and director modes, is of primary importance. The main tools for study of a rational selection of manual and director vehicle control systems and as an aid in formulating recommendations for optimum crew-automatic control system interactions are special complex and functional flight simulator test stands. The proposed simulator stand includes a powerful digital computer complex combined with the control system of the centrifuge. The interior of a pilot's vehicle cabin is imitated. A situation image system, pyscho-physical monitoring system, physician, centrifuge operator, and instructor stations are linked with the test stand.

  5. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  6. A Review and Comparison of the Reliabilities of the MMPI-2, MCMI-III, and PAI Presented in Their Respective Test Manuals

    Science.gov (United States)

    Wise, Edward A.; Streiner, David L.; Walfish, Steven

    2010-01-01

    This article provides a review of the literature to determine the most frequently used personality tests. Based on this review, internal consistency and test-retest reliability coefficients from the test manuals for the Minnesota Multiphasic Personality Inventory-2 (MMPI-2), Millon Clinical Multiaxial Inventory-III (MCMI-III), and Personality…

  7. Evaluation of manual and automatic manually triggered ventilation performance and ergonomics using a simulation model.

    Science.gov (United States)

    Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan

    2014-05-01

    In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of

  8. NV/YMP RADIOLOGICAL CONTROL MANUAL

    Energy Technology Data Exchange (ETDEWEB)

    U.S. DEPARTMENT OF ENERGY, NATIONAL NUCLEAR SECURITY ADMINISTRATION NEVADA SITE OFFICE; BECHTEL NEVADA

    2004-11-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual.

  9. NV/YMP RADIOLOGICAL CONTROL MANUAL

    International Nuclear Information System (INIS)

    2004-01-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual

  10. The operation and maintenance manual

    International Nuclear Information System (INIS)

    Klein, W.; Krotil, H.; Stoll, A.

    1975-01-01

    The Operating Manual is one of many technical documents which the nuclear power plant operator needs for ensuring safe operation. For the operating staff, however, there is only one document, namely the Operating Manual. It contains, appropriately arranged, the necessary system and other diagrams, drawings, lists, licensing documents and similar material, which are necessary for understanding the design, for testing, for obtaining the operating licence and for the operation of individual systems and of the entire plant. (orig./RW) [de

  11. Equipment Qualification Data Base user manual

    International Nuclear Information System (INIS)

    Decker, Q.R.; Fackrell, L.J.; Fitch, L.R.; Meeky, O.B.

    1985-09-01

    This manual details the Equipment Qualification Data Base (EQDB), its usage, and contents. The EQDB consists of two files; the Plant Qualification File (PQF) and the Equipment Qualification File (EQF). The PQF contains plant specific environmental data and the EQF contains summaries of various test results. Two data management systems are used to manipulate the data and are discussed in this manual. SAS Institute System 2000 (S2K) is the management system for the PQF and Query Update (QU) is the operating system for the EQF. Each management system contains report writers. These writers and how to use them are discussed in detail in this manual

  12. Intra‐Target Microdosing – A Novel Drug Development Approach: Proof of Concept, Safety, and Feasibility Study in Humans

    Science.gov (United States)

    MacLeod, D; Lee, K; Santoro, A; DeMasi, DK; Hawk, T; Feinglos, M; Rowland, M; Noveck, RJ

    2017-01-01

    Abstract Intra‐Target Microdosing (ITM) is a novel drug development approach aimed at increasing the efficiency of first‐in‐human (FIH) testing of new molecular entities (NMEs). ITM combines intra‐target drug delivery and “microdosing,” the subpharmacological systemic exposure. We hypothesized that when the target tissue is small (about 1/100th of total body mass), ITM can lead to target therapeutic‐level exposure with minimal (microdose) systemic exposure. Each of five healthy male volunteers received insulin microdose into the radial artery or full therapeutic dose intravenously in separate visits. Insulin and glucose levels were similar between systemic administration and ITM administration in the ipsilateral hand, and glucose levels demonstrated a reduction in the ipsilateral hand but not in the contralateral hand. Positron emission tomography (PET) imaging of 18F‐fluorodeoxyglucose (FDG) uptake demonstrated differences between the ipsilateral and contralateral arms. The procedures were safe and well‐tolerated. Results are consistent with ITM proof‐of‐concept (POC) and demonstrate the ethical, regulatory, and logistical feasibility of the approach. PMID:28689370

  13. REBA experimenters' manual

    International Nuclear Information System (INIS)

    Schuch, R.L.

    1977-04-01

    The REBA is a high-energy, pulsed electron beam or bremsstrahlung x-ray generator whose operational purpose is to provide an energy source of short duration for conducting experiments, primarily to determine material responses to rapid surface and in-depth deposition of energy. The purpose of this manual is to serve as a basic source of information for prospective users of REBA. Included is a brief discussion of the design and operation of the facility as well as a summary of output characteristics for electron beam modes and environmental data for x-ray operation. The manual also contains a description of the REBA experimental facilities, including geometry of the test cell, instrumentation and data collection capabilities, and services and support available to experimenters

  14. Peace Corps Aquaculture Training Manual. Training Manual T0057.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This Peace Corps training manual was developed from two existing manuals to provide a comprehensive training program in fish production for Peace Corps volunteers. The manual encompasses the essential elements of the University of Oklahoma program that has been training volunteers in aquaculture for 25 years. The 22 chapters of the manual are…

  15. Davis PV plant operation and maintenance manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    This operation and maintenance manual contains the information necessary to run the Photovoltaics for Utility Scale Applications (PVUSA) test facility in Davis, California. References to more specific information available in drawings, data sheets, files, or vendor manuals are included. The PVUSA is a national cooperative research and demonstration program formed in 1987 to assess the potential of utility scale photovoltaic systems.

  16. Eddy current manual: v.1

    International Nuclear Information System (INIS)

    Cecco, V.S.; Van Drunen, G.; Sharp, F.L.

    1983-09-01

    This training and reference manual was assembled to provide those involved in eddy current testing with both the fundamental principles of the technique as well as the knowledge to deal with often complicated test results. A non-rigorous approach is used to simplify complex physical phenomena. Emphasis is placed on proper choice of test frequency and signal interpretation. Defect detection and diagnosis receive particular attention. Design and construction of probes are covered extensively since probes play a key role in eddy current testing. The advantages and limitations of various probe types are discussed. Electromagnetic theory, instrumentation, test methods and signal analysis are covered. Simplified derivations of probe response to test parameters are presented to develop a basic understanding of eddy current behaviour. Eddy current signals are presented on impedance plane diagrams throughout the manual since this is the most common display on modern, general purpose instruments. The use of Σphase lagΣ in signal analysis is covered in detail. To supplement theory, practical examples are presented to develop proficiency in performing inspections, and to illustrate how basic principles are applied to diagnose real signals

  17. Eddy current manual, volume 2

    International Nuclear Information System (INIS)

    Cecco, V.S.; Van Drunen, G.; Sharp, F.L.

    1984-09-01

    This report on eddy current testing is divided into three sections: (a) Demonstration of Basic Principles, (b) Practical (Laboratory) Tests and, (c) Typical Certification Questions. It is intended to be used as a supplement to ΣEddy Current Manual, Volume 1Σ (AECL-7523) during CSNDT Foundation Level II and III courses

  18. Oxygen uptake during peak graded exercise and single-stage fatigue tests of wheelchair propulsion in manual wheelchair users and the able-bodied.

    Science.gov (United States)

    Keyser, R E; Rodgers, M M; Gardner, E R; Russell, P J

    1999-10-01

    To determine if a single-stage, submaximal fatigue test on a wheelchair ergometer would result in higher than expected energy expenditure. An experimental survey design contrasting physiologic responses during peak graded exercise tests and fatigue tests. A rehabilitation science laboratory that included a prototypical wheelchair ergometer, open-circuit spirometry system, and heart rate monitor. Nine able-bodied non-wheelchair users (the NWC group: 6 men and 3 women, mean +/- SD age 30 +/- 7yrs) and 15 manual wheelchair users (the WC group: 12 men and 3 women, age 40 +/- 9yrs, time in wheelchair 16 +/- 9yrs). No subject had any disease, medication regimen, or upper body neurologic, orthopedic, or other condition that would limit wheelchair exercise. Peak oxygen uptake (VO2) for graded exercise testing and during fatigue testing, using a power output corresponding to 75% peak aerobic capacity on graded exercise test. In the WC group, VO2 at 6 minutes of fatigue testing was not significantly different from peak VO2. In the NWC group, VO2 was similar to the expected level throughout fatigue testing. Energy expenditure was higher than expected in the WC group but not in the NWC group. Fatigue testing may provide a useful evaluation of cardiorespiratory status in manual wheelchair users.

  19. Value of stress ultrasound for the diagnosis of chronic ankle instability compared to manual anterior drawer test, stress radiography, magnetic resonance imaging, and arthroscopy.

    Science.gov (United States)

    Cho, Jae Ho; Lee, Doo Hyung; Song, Hyung Keun; Bang, Joon Young; Lee, Kyung Tai; Park, Young Uk

    2016-04-01

    Clinicians frequently diagnose chronic ankle instability using the manual anterior drawer test and stress radiography. However, both examinations can yield incorrect results and do not reveal the extent of ankle instability. Stress ultrasound has been reported to be a new diagnostic tool for the diagnosis of chronic ankle instability. The purpose of this study was to assess the diagnostic value of stress ultrasound for chronic ankle instability compared to the manual anterior drawer test, stress radiography, magnetic resonance imaging (MRI), and arthroscopy. Twenty-eight consecutive patients who underwent ankle arthroscopy and subsequent modified Broström repair for treatment of chronic ankle instability were included. The arthroscopic findings were used as the reference standard. A standardized physical examination (manual anterior drawer test), stress radiography, MRI, and stress ultrasound were performed to assess the anterior talofibular ligament (ATFL) prior to operation. Ultrasound images were taken in the resting position and the maximal anterior drawer position. Grade 3 lateral instability was verified arthroscopically in all 28 cases with a clinical diagnosis (100%). Twenty-two cases showed grade III instability on the manual anterior drawer test (78.6%). Twenty-four cases displayed anterior translation exceeding 5 mm on stress radiography (86%), and talar tilt angle exceeded 15° in three cases (11 %). Nineteen cases displayed a partial chronic tear (change in thickness or signal intensity), and nine cases displayed complete tear on MRI (100%). Lax and wavy ATFL was evident on stress ultrasound in all cases (100 %). The mean value of the ATFL length was 2.8 ± 0.3 cm for the stressed condition and 2.1 ± 0.2 cm for the resting condition (p radiography. III.

  20. Preliminary test of remote manual instrumentation & control type system for vacuum unit of 350 KeV / 10 mA electron beam machine

    International Nuclear Information System (INIS)

    Sudiyanto

    2003-01-01

    Remote manual instrumentation & control type for vacuum unit of 350 KeV/10 mA Electron Beam Machine is being completed. The system consisting of a remote manual controlled and a remote acquisition system. A remote manual (50 m) controlled is based on the on/off status of 220 Volt terminal supply for pneumatic valves and vacuum pumps, in this case the power supply switch of pneumatic valves and pumps have already been selected On. Remote acquisition of vacuum level can be done by using a CCTV camera which is place in front of the panning gauge and TGP.300 Balzer unit.The CCTV system equipped with 6 cameras, one TV monitor and a multiplexer unit to arranged a selected picture on it. One of the camera was mounted on the rotator unit, it can be controlled (rotating left / right) for different monitoring orientations required by using infrared controller. A trial test of the remote manual control system for vacuum unit of the Electron Beam Machine showed a good performance. (author)

  1. Effect of cold conditions on manual performance while wearing petroleum industry protective clothing.

    Science.gov (United States)

    Wiggen, Øystein Nordrum; Heen, Sigri; Færevik, Hilde; Reinertsen, Randi Eidsmo

    2011-01-01

    The purpose of this study was to investigate manual performance and thermal responses during low work intensity in persons wearing standard protective clothing in the petroleum industry when they were exposed to a range of temperatures (5, -5, -15 and -25℃) that are relevant to environmental conditions for petroleum industry personnel in northern regions. Twelve men participated in the study. Protective clothing was adjusted for the given cold exposure according to current practices. The subjects performed manual tests five times under each environmental condition. The manual performance test battery consisted of four different tests: tactile sensation (Semmes-Weinstein monofilaments), finger dexterity (Purdue Pegboard), hand dexterity (Complete Minnesota dexterity test) and grip strength (grip dynamometer). We found that exposure to -5℃ or colder lowered skin and body temperatures and reduced manual performance during low work intensity. In conclusion the current protective clothing at a given cold exposure is not adequate to maintain manual performance and thermal balance for petroleum workers in the high north.

  2. VLE measurements using a static cell vapor phase manual sampling method accompanied with an empirical data consistency test

    International Nuclear Information System (INIS)

    Freitag, Joerg; Kosuge, Hitoshi; Schmelzer, Juergen P.; Kato, Satoru

    2015-01-01

    Highlights: • We use a new, simple static cell vapor phase manual sampling method (SCVMS) for VLE (x, y, T) measurement. • The method is applied to non-azeotropic, asymmetric and two-liquid phase forming azeotropic binaries. • The method is approved by a data consistency test, i.e., a plot of the polarity exclusion factor vs. pressure. • The consistency test reveals that with the new SCVMS method accurate VLE near ambient temperature can be measured. • Moreover, the consistency test approves that the effect of air in the SCVMS system is negligible. - Abstract: A new static cell vapor phase manual sampling (SCVMS) method is used for the simple measurement of constant temperature x, y (vapor + liquid) equilibria (VLE). The method was applied to the VLE measurements of the (methanol + water) binary at T/K = (283.2, 298.2, 308.2 and 322.9), asymmetric (acetone + 1-butanol) binary at T/K = (283.2, 295.2, 308.2 and 324.2) and two-liquid phase forming azeotropic (water + 1-butanol) binary at T/K = (283.2 and 298.2). The accuracy of the experimental data was approved by a data consistency test, that is, an empirical plot of the polarity exclusion factor, β, vs. the system pressure, P. The SCVMS data are accurate, because the VLE data converge to the same lnβ vs. lnP straight line determined from conventional distillation-still method and a headspace gas chromatography method

  3. An aircraft-borne chemical ionization – ion trap mass spectrometer (CI-ITMS for fast PAN and PPN measurements

    Directory of Open Access Journals (Sweden)

    H. Schlager

    2011-02-01

    Full Text Available An airborne chemical ionization ion trap mass spectrometer instrument (CI-ITMS has been developed for tropospheric and stratospheric fast in-situ measurements of PAN (peroxyacetyl nitrate and PPN (peroxypropionyl nitrate. The first scientific deployment of the FASTPEX instrument (FASTPEX = Fast Measurement of Peroxyacyl nitrates took place in the Arctic during 18 missions aboard the DLR research aircraft Falcon, within the framework of the POLARCAT-GRACE campaign in the summer of 2008. The FASTPEX instrument is described and characteristic properties of the employed ion trap mass spectrometer are discussed. Atmospheric data obtained at altitudes of up to ~12 km are presented, from the boundary layer to the lowermost stratosphere. Data were sampled with a time resolution of 2 s and a 2σ detection limit of 25 pmol mol−1. An isotopically labelled standard was used for a permanent on-line calibration. For this reason the accuracy of the PAN measurements is better than ±10% for mixing ratios greater than 200 pmol mol−1. PAN mixing ratios in the summer Arctic troposphere were in the order of a few hundred pmol mol−1 and generally correlated well with CO. In the Arctic boundary layer and lowermost stratosphere smaller PAN mixing ratios were observed due to a combination of missing local sources of PAN precursor gases and efficient removal processes (thermolysis/photolysis. PPN, the second most abundant PAN homologue, was measured simultaneously. Observed PPN/PAN ratios range between ~0.03 and 0.3.

  4. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    OpenAIRE

    ?nce, Fatma Demet; Ellida?, Hamit Ya?ar; Koseo?lu, Mehmet; ?im?ek, Ne?e; Yal??n, H?lya; Zengin, Mustafa Osman

    2016-01-01

    Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA), Dirui...

  5. Intra-Target Microdosing - A Novel Drug Development Approach: Proof of Concept, Safety, and Feasibility Study in Humans.

    Science.gov (United States)

    Burt, T; MacLeod, D; Lee, K; Santoro, A; DeMasi, D K; Hawk, T; Feinglos, M; Rowland, M; Noveck, R J

    2017-09-01

    Intra-Target Microdosing (ITM) is a novel drug development approach aimed at increasing the efficiency of first-in-human (FIH) testing of new molecular entities (NMEs). ITM combines intra-target drug delivery and "microdosing," the subpharmacological systemic exposure. We hypothesized that when the target tissue is small (about 1/100th of total body mass), ITM can lead to target therapeutic-level exposure with minimal (microdose) systemic exposure. Each of five healthy male volunteers received insulin microdose into the radial artery or full therapeutic dose intravenously in separate visits. Insulin and glucose levels were similar between systemic administration and ITM administration in the ipsilateral hand, and glucose levels demonstrated a reduction in the ipsilateral hand but not in the contralateral hand. Positron emission tomography (PET) imaging of 18 F-fluorodeoxyglucose (FDG) uptake demonstrated differences between the ipsilateral and contralateral arms. The procedures were safe and well-tolerated. Results are consistent with ITM proof-of-concept (POC) and demonstrate the ethical, regulatory, and logistical feasibility of the approach. © 2017 The Authors. Clinical and Translational Science published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.

  6. TALENT user's manual.

    Energy Technology Data Exchange (ETDEWEB)

    Merchant, Bion John

    2012-01-01

    The Ground-Based Monitoring R and E Component Evaluation project performs testing on the hardware components that make up Seismic and Infrasound monitoring systems. The majority of the testing is focused on the Digital Waveform Recorder (DWR), Seismic Sensor, and Infrasound Sensor. The software tool used to capture and analyze the data collected from testing is called TALENT: Test and Analysis Evaluation Tool. This document is the manual for using TALENT. Other reports document the testing procedures that are in place (Kromer, 2007) and the algorithms employed in the test analysis (Merchant, 2011).

  7. TA-55 change control manual

    International Nuclear Information System (INIS)

    Blum, T.W.; Selvage, R.D.; Courtney, K.H.

    1997-11-01

    This manual is the guide for initiating change at the Plutonium Facility, which handles the processing of plutonium as well as research on plutonium metallurgy. It describes the change and work control processes employed at TA-55 to ensure that all proposed changes are properly identified, reviewed, approved, implemented, tested, and documented so that operations are maintained within the approved safety envelope. All Laboratory groups, their contractors, and subcontractors doing work at TA-55 follow requirements set forth herein. This manual applies to all new and modified processes and experiments inside the TA-55 Plutonium Facility; general plant project (GPP) and line item funded construction projects at TA-55; temporary and permanent changes that directly or indirectly affect structures, systems, or components (SSCs) as described in the safety analysis, including Facility Control System (FCS) software; and major modifications to procedures. This manual does not apply to maintenance performed on process equipment or facility SSCs or the replacement of SSCs or equipment with documented approved equivalents

  8. Factors associated with high physical exertion during manual lifting

    DEFF Research Database (Denmark)

    Andersen, Lars L.; Sundstrup, Emil; Brandt, Mikkel

    2018-01-01

    BACKGROUND: High physical exertion during work is a risk factor for back pain and long-term sickness absence. OBJECTIVE: To investigate which factors are associated with physical exertion during manual lifting. METHODS: From 14 workplaces across Denmark, 200 blue-collar workers reported perceived...... physical exertion (Borg-CR10) during manual lifting from floor to table height of 5, 10, 20 and 30 kg at the beginning and end of the working day. The workers also responded to a questionnaire and went through testing of isometric back muscle strength. Associations were modelled using logistic regression...... during manual lifting in blue-collar workers. These factors should be considered when planning work with manual lifting for individual workers....

  9. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

    Directory of Open Access Journals (Sweden)

    Nussbaumer Silvio

    2010-08-01

    Full Text Available Abstract Background The aims of this study were to evaluate the construct validity (known group, concurrent validity (criterion based and test-retest (intra-rater reliability of manual goniometers to measure passive hip range of motion (ROM in femoroacetabular impingement patients and healthy controls. Methods Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study. Results The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P P Conclusions The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.

  10. Manual Therapy

    OpenAIRE

    Hakgüder, Aral; Kokino, Siranuş

    2002-01-01

    Manual therapy has been used in the treatment of pain and dysfunction of spinal and peripheral joints for more than a hundred years. Manual medicine includes manipulation, mobilization, and postisometric relaxation techniques. The aim of manual therapy is to enhance restricted movement caused by blockage of joints keeping postural balance, restore function and maintain optimal body mechanics. Anatomic, biomechanical, and neurophysiological evaluations of the leucomotor system is essential for...

  11. Design/CPN. A Reference Manual

    DEFF Research Database (Denmark)

    Jensen et. al, Kurt

    /CPN WWW pages. To speed up the access to the Design/CPN manuals we recommend to keep a local copy - which may be shared by all users in your organisation. In this way you do not need to go via our WWW server each time you need to look in a manual. For some of the largest manuals, we also supply files......Note: The manuals are available as PDF files . There are two sets of manuals - one for the Unix platform and another for the Mac platform. Each set of manual consists of: Tutorial (for the Design/CPN editor and simulator) Reference Manual (for the Design/CPN editor and simulator) Programmer......'s Manual (with Design/OA functions and Charts) Occurrence Graph Manual (integrated tutorial and reference manual) OE/OS Graph Manual (integrated tutorial and reference manual) Other Manuals (e.g. a short overview of CPN ML).   The Tutorial, Reference Manual and Programmer's Manual are made for Design...

  12. Caltrans : construction manual

    Science.gov (United States)

    2009-08-01

    Caltrans intends this manual as a resource for all personnel engaged in contract administration. The manual establishes policies and procedures for the construction phase of Caltrans projects. However, this manual is not a contract document. It impos...

  13. PAVECHECK : training material updated user's manual including GPS.

    Science.gov (United States)

    2009-01-01

    PAVECHECK is a software package used to integrate nondestructive test data from various testing systems to provide the pavement engineer with a comprehensive evaluation of both surface and subsurface conditions. This User's Manual is intended to demo...

  14. A Manual for Basic Techniques of Data Analysis and Distribution

    OpenAIRE

    Alvi, Mohsin

    2014-01-01

    A manual is designed to support and help the basic concepts of statistics and its implications in econometric, beside this, interpretation of further statistical techniques have been shown as well by illustrations and graphical methods. It is comprised on several instances of test, obtained from statistical software like SPSS, E-views, Stata and R-language with the understanding of their research models and essentials for the running the test. A basic of manual is included on two elements, fi...

  15. Laboratory manual for salt mixing test in rod bundles

    International Nuclear Information System (INIS)

    Khan, H.U.R.; Chiu, C.; Todreas, N.

    1978-10-01

    This report is a Laboratory Manual dealing with the procedure employed during Salt Tracer Experiments, which are used for evaluating the hydraulic characteristics of a rod bundle. A description of the standard equipment used is given together with details of manufacture of non-standard items i.e., probes used for detecting the salt-concentration. Details of bundle construction have not been included as they are available in the references cited. An attempt has also been made to point out potential trouble areas and procedures

  16. HERMES II experimenters' manual (revised)

    International Nuclear Information System (INIS)

    Schuch, R.L.

    1977-04-01

    The HERMES II is a high-intensity laboratory photon source for gamma-ray radiation effects experiments as well as a high-energy pulsed electron beam generator for a variety of potential applications. The purpose of this manual is to serve as a basic source of information for prospective users of HERMES. Included is a brief discussion of the design and operation of the accelerator system as well as a summary of environmental data for x-ray operation and output characteristics for electron beam modes. The manual also contains a description of the HERMES experimental facilities, including geometry of the test cell, instrumentation and data collection capabilities, and services and support available to experimenters

  17. RRFC hardware operation manual

    International Nuclear Information System (INIS)

    Abhold, M.E.; Hsue, S.T.; Menlove, H.O.; Walton, G.

    1996-05-01

    The Research Reactor Fuel Counter (RRFC) system was developed to assay the 235 U content in spent Material Test Reactor (MTR) type fuel elements underwater in a spent fuel pool. RRFC assays the 235 U content using active neutron coincidence counting and also incorporates an ion chamber for gross gamma-ray measurements. This manual describes RRFC hardware, including detectors, electronics, and performance characteristics

  18. PROSA version 4.0 manual

    International Nuclear Information System (INIS)

    Bicking, U.; Golly, W.; Peter, N.; Seifert, R.

    1991-05-01

    This report includes a comprehensive manual of the computer program PROSA which illustrate the handling and functioning of PROSA. The manual PROSA 4.0 (FORTRAN 77) describes the PC Version of PROSA including its program moduls. The PROSA program package is a statistical tool to decide on the basis of statistical assumptions whether in a given sequence of material balance periods a loss of material might have occurred. The evaluation of the material balance data is based on statistical test procedures. In the present PROSA Version 4.0 the three tests CUMUF test, PAGE's test and GEMUF test are applied to a sequence of material balances. PROSA Version 4.0 supports a real sequential evaluation. That means, PROSA is not only able to evaluate a series of MUF values sequentially after the campaign has finished, but also real sequentially during the campaign. PROSA Version 4.0 is a menu-guided computer program. Data input can be performed either by diskette or by key-enter. Result output is primarily an information whether or not an alarm is indicated. This information can be displayed either numerically or graphically. Therefore, a comfortable graphical output utility is attached to PROSA 4.0. The program moduls are compiled and linked with the Ryan Mc-Farland Compiler. The PROSA graphical utility uses the PLOT88 Library of Plotworks, Inc. (orig./HP) [de

  19. CSTEM User Manual

    Science.gov (United States)

    Hartle, M.; McKnight, R. L.

    2000-01-01

    This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.

  20. High-Level Location Based Search Services That Improve Discoverability of Geophysical Data in the Virtual ITM Observatory

    Science.gov (United States)

    Schaefer, R. K.; Morrison, D.; Potter, M.; Barnes, R. J.; Nylund, S. R.; Patrone, D.; Aiello, J.; Talaat, E. R.; Sarris, T.

    2015-12-01

    The great promise of Virtual Observatories is the ability to perform complex search operations across the metadata of a large variety of different data sets. This allows the researcher to isolate and select the relevant measurements for their topic of study. The Virtual ITM Observatory (VITMO) has many diverse geophysical datasets that cover a large temporal and spatial range that present a unique search problem. VITMO provides many methods by which the user can search for and select data of interest including restricting selections based on geophysical conditions (solar wind speed, Kp, etc) as well as finding those datasets that overlap in time. One of the key challenges in improving discoverability is the ability to identify portions of datasets that overlap in time and in location. The difficulty is that location data is not contained in the metadata for datasets produced by satellites and would be extremely large in volume if it were available, making searching for overlapping data very time consuming. To solve this problem we have developed a series of light-weight web services that can provide a new data search capability for VITMO and others. The services consist of a database of spacecraft ephemerides and instrument fields of view; an overlap calculator to find times when the fields of view of different instruments intersect; and a magnetic field line tracing service that maps in situ and ground based measurements to the equatorial plane in magnetic coordinates for a number of field models and geophysical conditions. These services run in real-time when the user queries for data. These services will allow the non-specialist user to select data that they were previously unable to locate, opening up analysis opportunities beyond the instrument teams and specialists, making it easier for future students who come into the field.

  1. İşitme engelli okuyucuların okuma sürecinde Türkçenin ve Türk İşaret dilinin biçim-sözdizim özellikleri

    Directory of Open Access Journals (Sweden)

    Necla Işıkdoğan Uğurlu

    2017-07-01

    Full Text Available İşitme engelli okuyucuların bir metni bütünüyle kavrayabilmesi için biçimbirimsel ve biçim-sözdizimsel farkındalık becerilerinin gelişmesi gerekmektedir. En küçük birimleri inceleyen biçimbilim sadece birimleri değil, metnin tümünün kavranmasını hedeflemektedir. Kısacası biçimbirimsel ve biçim-sözdizimsel becerilerde öğrencilerin sahip oldukları farkındalığın, onların sesbilim, sözdizim, anlambilim gibi diğer dil bileşenlerine ilişkin becerilerde de farkındalık sağlamaktadır. Günümüzde okuma becerilerini kazanmada, dil bileşenlerini kapsayan biçimbirimsel ve biçim-sözdizimsel farkındalık becerilerinin önemi giderek daha fazla sayıda vurgulanmaktadır. İşitme engelli okuyucuların işaret dili yeterliği ile okuma yazma becerilerinin kazanımı arasında pozitif bir ilişki olmakla birlikte her iki dilin de kendi dilbilimsel kurallarının olduğu ve okuryazarlık becerilerinin kazanılmasında diller arası olumlu bir etkileşimin olduğu bilinmektedir. Bu nedenle de işaret dili yeterliliği ile okuma yazma becerileri arasındaki bu olumlu etkileşimden yola çıkarak her iki dilin biçim-sözdizimsel özelliklerinin öğrenilerek işitme engelli çocukların okuma yazma becerilerinin kazanımında etkili kullanımına yer verilmelidir. Bu derlemede, okuma becerilerinde Türk İşaret Dili (TİD ve Türkçe olmak üzere her iki dilin biçimbilimsel ve biçim-sözdizimsel özellikleri eylemlerde uyum ve zaman kategorileri açısından karşılaştırmalı olarak incelenmektedir. To be able to understand a text entirely, person second language need to develop both their morphemic and morpho-syntactic awareness. Morphology-which involves the evaluation of the smallest components-aims to ensure not only the understanding of individual components, but also the entire text. Students’ awareness and knowledge of morphemic and morpho-syntactic skills positively affect their awareness and

  2. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-06-18

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  3. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-03-25

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  4. First series of total robotic hysterectomy (TRH) using new integrated table motion for the da Vinci Xi: feasibility, safety and efficacy.

    Science.gov (United States)

    Giannini, Andrea; Russo, Eleonora; Mannella, Paolo; Palla, Giulia; Pisaneschi, Silvia; Cecchi, Elena; Maremmani, Michele; Morelli, Luca; Perutelli, Alessandra; Cela, Vito; Melfi, Franca; Simoncini, Tommaso

    2017-08-01

    To present the first case series of total robotic hysterectomy (TRH), using integrated table motion (ITM), which is a new feature comprising a unique operating table by Trumpf Medical that communicates wirelessly with the da Vinci Xi surgical system. ITM has been specifically developed to improve multiquadrant robotic surgery such as that conducted in colorectal surgery. Between May and October 2015, a prospective post-market study was conducted on ITM in the EU in 40 cases from different specialties. The gynecological study group comprised 12 patients. Primary endpoints were ITM feasibility, safety and efficacy. Ten patients underwent TRH. Mean number of ITM moves was three during TRH; there were 31 instances of table moves in the ten procedures. Twenty-eight of 31 ITM moves were made to gain internal exposure. The endoscope remained inserted during 29 of the 31 table movements (94%), while the instruments remained inserted during 27 of the 31 moves (87%). No external instrument collisions or other problems related to the operating table were noted. There were no ITM safety-related observations and no adverse events. This preliminary study demonstrated the feasibility, safety and efficacy of ITM for the da Vinci Xi surgical system in TRH. ITM was safe, with no adverse events related to its use. Further studies will be useful to define the real role and potential benefit of ITM in gynecological surgery.

  5. Single-run determination of polybrominated diphenyl ethers (PBDEs) di- to deca-brominated in fish meal, fish oil and fish feed by isotope dilution: Application of automated sample purification and gas chromatography/ion trap tandem mass spectrometry (GC/ITMS)

    International Nuclear Information System (INIS)

    Blanco, Sonia Lucia; Vieites, Juan M.

    2010-01-01

    The present paper describes the application of automated cleanup and fractionation procedures of the Power Prep system (Fluid Management Systems) for the determination of polybrominated diphenyl ethers (PBDEs) in feeding stuffs and fish meal and oil. Gas chromatography (GC) separation followed by ion trap tandem mass spectrometry detection in EI mode (ITMS) allowed the analysis of di- to deca-BDEs in the samples matrices used in fish aquaculture. The method developed enabled the determination of 26 native PBDE congeners and 11 13 C 12 -labelled congeners, including deca-BDE 209, in a single-run analysis, using isotope dilution. The automated cleanup, consisting of a succession of multilayer silica and basic alumina columns previously applied by Wyrzykowska et al. (2009) in combustion flue gas, was succesfully applied in our complex matrices. The method allowed an increase in productivity, i.e. lower time was required to process samples, and simultaneous purification of several samples was achieved at a time, reducing analyst dedication and human error input. Average recoveries of 43-96% were obtained. GC/ITMS can overcome the complexity originating from the sample matrix, eliminating matrix effects by tandem MS, to enable the detection of congeners penta- to nona-BDEs where interferent masses were present. The provisional detection limits, estimated in the samples, were 5-30 pg for di-, tri-, tetra-, and penta-BDEs, 20-65 pg for hexa-, hepta-, octa- and nona-BDEs, and 105 pg for deca-BDE. Reduction of deca-BDE 209 blank values is of concern to ongoing research. Good accuracy was obtained by application of the whole procedure, representing an efficient, low-cost and fast alternative for routine analyses.

  6. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

    Science.gov (United States)

    İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman

    2016-08-01

    Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.

  7. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  8. Reducing Lead in Drinking Water: A Manual for Minnesota's Schools.

    Science.gov (United States)

    Minnesota State Dept. of Health, St. Paul.

    This manual was designed to assist Minnesota's schools in minimizing the consumption of lead in drinking water by students and staff. It offers step-by-step instructions for testing and reducing lead in drinking water. The manual answers: Why is lead a health concern? How are children exposed to lead? Why is lead a special concern for schools? How…

  9. Sierra/SolidMechanics 4.46 Example Problems Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Plews, Julia A.; Crane, Nathan K; de Frias, Gabriel Jose; Le, San; Littlewood, David John; Merewether, Mark Thomas; Mosby, Matthew David; Pierson, Kendall H.; Porter, Vicki L.; Shelton, Timothy; Thomas, Jesse David; Tupek, Michael R.; Veilleux, Michael

    2018-03-01

    Presented in this document are tests that exist in the Sierra/SolidMechanics example problem suite, which is a subset of the Sierra/SM regression and performance test suite. These examples showcase common and advanced code capabilities. A wide variety of other regression and verification tests exist in the Sierra/SM test suite that are not included in this manual.

  10. INTRA/Mod3.2. Manual and code description. Volume 2 - User's manual

    International Nuclear Information System (INIS)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User's Manual is an input description. This document, the User's Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  11. Reliability of the Spanish version of the wheelchair skills test 4.2 for manual wheelchair users with spinal cord injury.

    Science.gov (United States)

    Passuni, Diego; Dalzotto, Elisa; F Gath, Christian; Buffetti, Eliana; Elizalde, Milagros; Jarmoluk, Verónica; Russo, Maria J; Intruvini, Silvia; Olmos, Lisandro E; Freixes, Orestes

    2018-05-03

    Cross-sectional. The majority of people with a spinal cord injury (SCI) are dependent on wheelchair for their mobility. Approximately, 36% of wheelchair users reported that obstacles such as curbs, uneven terrain, flooring surfaces and thresholds were barriers to mobility. Several studies have shown that assessment and training of wheelchair skills leads to improvements in those skills. The purpose of our study was to translate the Wheelchair Skill Test (4.2) and its report form into Spanish and then determine the inter-rater reliability of the WST 4.2 for manual wheelchairs operated by their users. Rehabilitation Unit, FLENI Institute, Buenos Aires, Argentina. The translation was performed by a physical therapist with advanced English language skills and specialized in the treatment of SCI subjects. We administrated and video-recorded the WST 4.2 manual Spanish version in 11 SCI subjects. Two physical therapists received specific training for administering the test and scoring the record. The reliability of the total percentage WST score were statistically quantified by intraclass correlation coefficient (ICC). ICC values for Interrater were 0.998 (p skills had a 100 percentage of agreement. Percentage of agreement in the three skills that presented less rating agreement was 73%, 81 % and 82 %, respectively. The results show that the Spanish version of WST 4.2 is a reliable assessment tool to evaluate the skills capacity of spinal cord manual wheelchair users. Implications for rehabilitation Wheelchair users require a proficient management of various wheelchair skills to achieve maximum independence in daily life. Determining which wheelchair skills should be addressed during the rehabilitation process is of great importance for their correct training. The WST 4.2 is an appropriate assessment tool to determine the functional capacity of wheelchair users. Making available the WST 4.2 in the Spanish language and demonstrating its reliability in this language

  12. A dinamometria manual e seu uso na avaliação nutricional Hand grip strength test and its use in nutritional assessment

    Directory of Open Access Journals (Sweden)

    Michael Maia Schlüssel

    2008-04-01

    Full Text Available Esta revisão de literatura aborda aspectos metodológicos e fisiológicos da dinamometria manual. A dinamometria manual é um teste funcional do músculo esquelético que vem recebendo uma crescente atenção de clínicos e pesquisadores da área de saúde nos últimos anos. Recentemente, tem merecido atenção como indicador do estado nutricional, particularmente para pacientes internados. Dentre os principais fatores que influenciam esta medida, destacam-se o sexo, a idade, a estatura, a massa corporal e a mão dominante dos indivíduos. Os resultados desta revisão demonstram ainda que diversos outros fatores, relacionados ao protocolo de aferição, como a posição do indivíduo, o tipo de instrumento utilizado, o número de aferições realizadas, o intervalo de descanso entre as aferições, a presença de estímulo verbal e de um pré-teste, também podem influenciar os valores alcançados por um indivíduo em uma avaliação da dinamometria manual. Dessa forma, é importante que um protocolo de aferição padronizado seja desenvolvido, para que se obtenham medidas válidas de dinamometria manual. Ainda são escassos os estudos que propõem valores de referência para a dinamometria manual e a literatura ainda se ressente de valores de referência baseados em dados obtidos a partir de amostras de base populacional.This paper reviews the methodological and physiological aspects of hand grip strength measurement. Hand grip strength assesses skeletal muscle function and has received increasing attention from physicians and health-related researchers in the last years. Recently, it has deserved particular attention as an indicator of nutritional status, particularly in hospitalized patients. Sex, age, height, body mass and the dominant hand of the subjects are the main factors that influence the measure. The results of this review demonstrate that many other factors associated with the assessment protocol, such as the position of the

  13. Structures manual

    Science.gov (United States)

    2001-01-01

    This manual was written as a guide for use by design personnel in the Vermont Agency of Transportation Structures Section. This manual covers the design responsibilities of the Section. It does not cover other functions that are a part of the Structu...

  14. Ciencias 2. Manual do Professor (Science Teacher's Manual).

    Science.gov (United States)

    Raposo, Lucilia

    This is the teacher's manual for Ciencias 2, the second in a series of elementary science textbooks for Portuguese-speaking students. The student textbook contains 10 chapters and 57 activities. The teacher's manual presents an explanation of the educational goals and the organization of the content, Topics included are environment, the human,…

  15. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  16. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  17. Egyptian Mythological Manuals

    DEFF Research Database (Denmark)

    Jørgensen, Jens Kristoffer Blach

    From the hands of Greek mythographers a great number of myths have survived along with philosophical discussions of their meaning and relevance for the Greeks. It is little known that something similar existed in ancient Egypt where temple libraries and archives held scholarly literature used...... by the native priesthood, much of which has only been published in recent years. As part of this corpus of texts, the ancient Egyptian mythological manuals offer a unique perspective on how the Egyptian priesthood structured and interpreted Egyptian myths. The thesis looks at the different interpretative...... techniques used in the Tebtunis Mythological Manual (Second century CE) and the Mythological Manual of the Delta (Sixth century BCE) and the place of these manuals within the larger corpus of priestly scholarly literature from ancient Egypt. To organize the wealth of local myths the manuals use model...

  18. Users manual on database of the Piping Reliability Proving Tests at the Japan Atomic Energy Research Institute

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    Japan Atomic Energy Research Institute(JAERI) conducted Piping Reliability Proving Tests from 1975 to 1992 based upon the contracts between JAERI and Science and Technology Agency of Japan under the auspices of the special account law for electric power development promotion. The purposes of those tests are to prove the structural reliability of the primary cooling piping constituting a part of the pressure boundary in the water reactor power plants. The tests with large experimental facilities had ended already in 1990. After that piping reliability analysis by the probabilistic method followed until 1992. This report describes the users manual on databases about the test results using the large experimental facilities. Objectives of the piping reliability proving tests are to prove that the primary piping of the water reactor (1) be reliable throughout the service period, (2) have no possibility of rupture, (3) bring no detrimental influence on the surrounding instrumentations or equipments near the break location. The research activities using large scale piping test facilities are described. The present report does the database about the test results pairing the former report. With these two reports, all the feature of Piping Reliability Proving Tests is made clear. Briefings of the tests are described also written in Japanese or English. (author)

  19. Manual for reactor produced radioisotopes

    International Nuclear Information System (INIS)

    2003-01-01

    Radioisotopes find extensive applications in several fields including medicine, industry, agriculture and research. Radioisotope production to service different sectors of economic significance constitutes an important ongoing activity of many national nuclear programmes. Radioisotopes, formed by nuclear reactions on targets in a reactor or cyclotron, require further processing in almost all cases to obtain them in a form suitable for use. Specifications for final products and testing procedures for ensuring quality are also an essential part of a radioisotope production programme. The International Atomic Energy Agency (IAEA) has compiled and published such information before for the benefit of laboratories of Member States. The first compilation, entitled Manual of Radioisotope Production, was published in 1966 (Technical Reports Series No. 63). A more elaborate and comprehensive compilation, entitled Radioisotope Production and Quality Control, was published in 1971 (Technical Reports Series No. 128). Both served as useful reference sources for scientists working in radioisotope production worldwide. The 1971 publication has been out of print for quite some time. The IAEA convened a consultants meeting to consider the need for compiling an updated manual. The consultants recommended the publication of an updated manual taking the following into consideration: significant changes have taken place since 1971 in many aspects of radioisotope production; many radioisotopes have been newly introduced while many others have become gradually obsolete; considerable experience and knowledge have been gained in production of important radioisotopes over the years, which can be preserved through compilation of the manual; there is still a need for a comprehensive manual on radioisotope production methods for new entrants to the field, and as a reference. It was also felt that updating all the subjects covered in the 1971 manual at a time may not be practical considering the

  20. DOE explosives safety manual. Revision 7

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This manual prescribes the Department of Energy (DOE) safety rules used to implement the DOE safety policy for operations involving explosives. This manual is applicable to all DOE facilities engaged in operations of development, manufacturing, handling, storage, transportation, processing, or testing of explosives, pyrotechnics and propellants, or assemblies containing these materials. The standards of this manual deal with the operations involving explosives, pyrotechnics and propellants, and the safe management of such operations. The design of all new explosives facilities shall conform to the requirements established in this manual and implemented in DOE 6430.1A, ``General Design Criteria Manual.`` It is not intended that existing physical facilities be changed arbitrarily to comply with these provisions, except as required by law. Existing facilities that do not comply with these standards may continue to be used for the balance of their functional life, as long as the current operation presents no significantly greater risk than that assumed when the facility was originally designed and it can be demonstrated clearly that a modification to bring the facility into compliance is not feasible. However, in the case of a major renovation, the facility must be brought into compliance with current standards. The standards are presented as either mandatory or advisory. Mandatory standards, denoted by the words ``shall,`` ``must,`` or ``will,`` are requirements that must be followed unless written authority for deviation is granted as an exemption by the DOE. Advisory standards denoted by ``should`` or ``may`` are standards that may be deviated from with a waiver granted by facility management.

  1. Can Independent Judges Recognize Different Psychotherapies? An Experience with Manual-Guided Therapies.

    Science.gov (United States)

    Luborsky, Lester; And Others

    1982-01-01

    Tested whether independent judges could recognize three different manual-guided psychotherapies, drug counseling, supportive-expressive psychotherapy, and cognitive-behavioral using a special rating form containing scales for the characteristic aspects of each type. Results indicated that manual-guided therapies can be reliably recognized.…

  2. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    Directory of Open Access Journals (Sweden)

    Fatma Demet Ä°nce

    2016-08-01

    Full Text Available Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA, Dirui FUS-200 (DIRUI Industrial Co., China automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient and the rates within the same grading were evaluated. Results: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. Conclusion: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. Keywords: Urinalysis, Autoanalysis, Microscopy

  3. Effect of methylphenidate on neurocognitive test battery: an evaluation according to the diagnostic and statistical manual of mental disorders, fourth edition, subtypes.

    Science.gov (United States)

    Durak, Sibel; Ercan, Eyup Sabri; Ardic, Ulku Akyol; Yuce, Deniz; Ercan, Elif; Ipci, Melis

    2014-08-01

    The aims of this study were to evaluate the neuropsychological characteristics of the restrictive (R) subtype according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition and the attention-deficit/hyperactivity disorder (ADHD) combined (CB) type and predominantly inattentive (PI) type subtypes and to evaluate whether methylphenidate (MPH) affects neurocognitive test battery scores according to these subtypes. This study included 360 children and adolescents (277 boys, 83 girls) between 7 and 15 years of age who had been diagnosed with ADHD and compared the neuropsychological characteristics and MPH treatment responses of patients with the R subtype-which has been suggested for inclusion among the ADHD subtypes in the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition-with those of patients with the PI and CB subtypes. They did not differ from the control subjects in the complex attention domain, which includes Continuous Performance Test, Stroop test, and Shifting Attention Test, which suggests that the R subtype displayed a lower level of deterioration in these domains compared with the PI and CB subtypes. The patients with the CB and PI subtypes did not differ from the control subjects in the Continuous Performance Test correct response domain, whereas those with the R subtype presented a poorer performance than the control subjects. The R subtype requires a more detailed evaluation because it presented similar results in the remaining neuropsychological evaluations and MPH responses.

  4. Valve packing manual. A maintenance application guide

    International Nuclear Information System (INIS)

    Aikin, J.A.; McCutcheon, R.G.; Cumming, D.

    1997-01-01

    Since 1970, AECL Chalk River Mechanical Equipment Development (MED) branch has invested over 175 person years in testing related to improving valve packing performance. Successful developments, including, 'live-loading', reduced packing heights, and performance-based packing qualification testing have been implemented. Since 1986, MED and the Integrated Valve Actuator Program Task Force - Valve Packing Steering Committee (IVAP-VPSC) have been involved in the development of combination die-formed graphite packing for use in CANDU plants. Many reports, articles, and specifications have been issued. Due to the large amount of test data and reports, a more user-friendly document has been prepared for everyday use. The Valve Packing Manual is based on many years of MED research and testing, as well as operating experience from CANDU nuclear generating stations (NGS). Since 1986, packing research and testing has been funded by the CANDU Owners Group (COG), the Electric Power Research Institute (EPRI), and participating valve packing manufacturers. The Valve Packing Manual (VPM) provides topical summaries of all work related to valve packing done since 1985. It includes advances in configuration design, stem packing friction, materials specifications, and installation procedures. This paper provides an overview on the application of the VPM with a focus on qualification testing, packing configuration, and stem packing friction. (author)

  5. Thermo-economic analysis of integrated membrane-SMR ITM-oxy-combustion hydrogen and power production plant

    International Nuclear Information System (INIS)

    Sanusi, Yinka S.; Mokheimer, Esmail M.A.; Habib, Mohamed A.

    2017-01-01

    Highlights: •A methane reforming reactor integrated to an oxy-combustion plant is proposed. •Co-production of power and hydrogen was investigated and presented. •Optimal thermo-economic operating conditions of the system were identified and presented. •The ion transport membrane oxygen separation unit has the highest capital cost. •The combustor has the highest exergy destruction. -- Abstract: The demand for hydrogen has greatly increased in the last decade due to the stringent regulations enacted to address environmental pollution concerns. Natural gas reforming is currently the most mature technology for large-scale hydrogen production. However, it is usually associated with greenhouse gas emissions. As part of the strategies to reduce greenhouse gas emissions, new designs need to be developed to integrate hydrogen production facilities that are based on natural gas reforming with carbon capture facilities. In this study, we carried out energy, exergy and economic analysis of hydrogen production in a steam methane reforming reactor integrated with an oxy-combustion plant for co-production of power and hydrogen. The results show that the overall system efficiency and hydrogen production efficiency monotonically increase with increasing the combustor exit temperature (CET), increasing the amount of hydrogen extracted and decreasing the auxiliary fuel added to the system. The optimal thermo-economic operating conditions of the system were obtained as reformer pressure of 15 bar, auxiliary fuel factor of 0.8 and hydrogen extraction factor of 0.6. The production cost of hydrogen using the proposed system, under these optimal operating conditions, is within the range suggested by the International Energy Agency (IEA). Further analysis shows that the capital cost of the membrane-air separation unit (ITM) has the major share in the total investment cost of the system and constitutes 37% of the total capital cost of the system at the CET of 1500 K. The exergy

  6. Building Condition and Suitability Evaluation Manual.

    Science.gov (United States)

    MGT of America, Inc., Tallahassee, FL.

    This educational facility evaluation manual contains the overall building condition rating form and the supporting check sheets which have been field tested in several states and, where appropriate, modified for use in the Idaho School Facilities Needs Assessment. The exterior building condition form examines the foundation, structure, walls,…

  7. Validating New Software for Semiautomated Liver Volumetry--Better than Manual Measurement?

    Science.gov (United States)

    Noschinski, L E; Maiwald, B; Voigt, P; Wiltberger, G; Kahn, T; Stumpp, P

    2015-09-01

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33% vs. 57%, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04 min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience. Both tested types of software allow exact volumetry of resected liver parts. Preoperative prediction can be performed more accurately with the semiautomated software. The semiautomated software is nearly four times faster than the

  8. The Combined Effect of Cold and Moisture on Manual Performance.

    Science.gov (United States)

    Ray, Matthew; Sanli, Elizabeth; Brown, Robert; Ennis, Kerri Ann; Carnahan, Heather

    2018-02-01

    Objective The aim of this study was to investigate the combined effect of cold and moisture on manual performance and tactile sensitivity. Background People working in the ocean environment often perform manual work in cold and wet conditions. Although the independent effects of cold and moisture on hand function are known, their combined effect has not been investigated. Method Participants completed sensory (Touch-Test, two-point discrimination) and motor (Purdue Pegboard, Grooved Pegboard, reef knot untying) tests in the following conditions: dry hand, wet hand, cold hand, and cold and wet hand. Results For the Purdue Pegboard and knot untying tasks, the greatest decrement in performance was observed in the cold-and-wet-hand condition, whereas the decrements seen in the cold-hand and wet-hand conditions were similar. In the Grooved Pegboard task, the performance decrements exhibited in the cold-and-wet-hand condition and the cold-hand condition were similar, whereas no decrement was observed in the wet-hand condition. Tactile sensitivity was reduced in the cold conditions for the Touch-Test but not the two-point discrimination test. The combined effect of cold and moisture led to the largest performance decrements except when intrinsic object properties helped with grasp maintenance. The independent effects of cold and moisture on manual performance were comparable. Application Tools and equipment for use in the cold ocean environment should be designed to minimize the effects of cold and moisture on manual performance by including object properties that enhance grasp maintenance and minimize the fine-dexterity requirements.

  9. Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida

    Science.gov (United States)

    Mahony, Kate; Hunt, Adrienne; Daley, Deborah; Sims, Susan; Adams, Roger

    2009-01-01

    Reliability and measurement precision of manual muscle testing (MMT) and hand-held dynamometry (HHD) were compared for children with spina bifida. Strength measures were obtained of the hip flexors, hip abductors, and knee extensors of 20 children (10 males, 10 females; mean age 9 years 10 months; range: 5 to 15 years) by two experienced physical…

  10. Effects of Seated Postural Stability and Trunk and Upper Extremity Strength on Performance during Manual Wheelchair Propulsion Tests in Individuals with Spinal Cord Injury: An Exploratory Study.

    Science.gov (United States)

    Gagnon, Dany H; Roy, Audrey; Gabison, Sharon; Duclos, Cyril; Verrier, Molly C; Nadeau, Sylvie

    2016-01-01

    Objectives. To quantify the association between performance-based manual wheelchair propulsion tests (20 m propulsion test, slalom test, and 6 min propulsion test), trunk and upper extremity (U/E) strength, and seated reaching capability and to establish which ones of these variables best predict performance at these tests. Methods. 15 individuals with a spinal cord injury (SCI) performed the three wheelchair propulsion tests prior to discharge from inpatient SCI rehabilitation. Trunk and U/E strength and seated reaching capability with unilateral hand support were also measured. Bivariate correlation and multiple linear regression analyses allowed determining the best determinants and predictors, respectively. Results. The performance at the three tests was moderately or strongly correlated with anterior and lateral flexion trunk strength, anterior seated reaching distance, and the shoulder, elbow, and handgrip strength measures. Shoulder adductor strength-weakest side explained 53% of the variance on the 20-meter propulsion test-maximum velocity. Shoulder adductor strength-strongest side and forward seated reaching distance explained 71% of the variance on the slalom test. Handgrip strength explained 52% of the variance on the 6-minute propulsion test. Conclusion. Performance at the manual wheelchair propulsion tests is explained by a combination of factors that should be considered in rehabilitation.

  11. Single-run determination of polybrominated diphenyl ethers (PBDEs) di- to deca-brominated in fish meal, fish oil and fish feed by isotope dilution: application of automated sample purification and gas chromatography/ion trap tandem mass spectrometry (GC/ITMS).

    Science.gov (United States)

    Blanco, Sonia Lucía; Vieites, Juan M

    2010-07-05

    The present paper describes the application of automated cleanup and fractionation procedures of the Power Prep system (Fluid Management Systems) for the determination of polybrominated diphenyl ethers (PBDEs) in feeding stuffs and fish meal and oil. Gas chromatography (GC) separation followed by ion trap tandem mass spectrometry detection in EI mode (ITMS) allowed the analysis of di- to deca-BDEs in the samples matrices used in fish aquaculture. The method developed enabled the determination of 26 native PBDE congeners and 11 (13)C(12)-labelled congeners, including deca-BDE 209, in a single-run analysis, using isotope dilution. The automated cleanup, consisting of a succession of multilayer silica and basic alumina columns previously applied by Wyrzykowska et al. (2009) [28] in combustion flue gas, was successfully applied in our complex matrices. The method allowed an increase in productivity, i.e. lower time was required to process samples, and simultaneous purification of several samples was achieved at a time, reducing analyst dedication and human error input. Average recoveries of 43-96% were obtained. GC/ITMS can overcome the complexity originating from the sample matrix, eliminating matrix effects by tandem MS, to enable the detection of congeners penta- to nona-BDEs where interferent masses were present. The provisional detection limits, estimated in the samples, were 5-30 pg for di-, tri-, tetra-, and penta-BDEs, 20-65 pg for hexa-, hepta-, octa- and nona-BDEs, and 105 pg for deca-BDE. Reduction of deca-BDE 209 blank values is of concern to ongoing research. Good accuracy was obtained by application of the whole procedure, representing an efficient, low-cost and fast alternative for routine analyses. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Gravity versus manual external rotation stress view in evaluating ankle stability: a prospective study.

    Science.gov (United States)

    LeBa, Thu-Ba; Gugala, Zbigniew; Morris, Randal P; Panchbhavi, Vinod K

    2015-06-01

    The purpose of this prospective study was to determine whether gravity versus manual external rotation stress testing effectively detects widening of the medial clear space in isolated ankle fractures when compared with the uninjured contralateral side. Manual external rotation stress and gravity stress tests were performed on injured and uninjured ankles of ankle fracture patients in a clinic setting. Medial clear space measurements were recorded and differences between gravity and manual stress views were determined. Twenty consecutive patients with ankle injury were enrolled in the study. When compared with the uninjured side, gravity stress views showed a statistically significant (P = .017) increase in medial clear space widening (1.85 ± 1.07 mm) compared with manual stress view widening (1.35 ± 1.04 mm). This study suggests that gravity stress views are as effective as manual external rotation stress views in detecting medial clear space widening in isolated fibular fractures. Diagnostic, Level II: Prospective, comparative trial. © 2014 The Author(s).

  13. INTRA/Mod3.2. Manual and code description. Volume 2 - User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User`s Manual is an input description. This document, the User`s Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  14. Pain management in patients with adolescent idiopathic scoliosis undergoing posterior spinal fusion: combined intrathecal morphine and continuous epidural versus PCA.

    Science.gov (United States)

    Ravish, Matthew; Muldowney, Bridget; Becker, Aimee; Hetzel, Scott; McCarthy, James J; Nemeth, Blaise A; Noonan, Kenneth J

    2012-12-01

    A retrospective case-comparison study. Compare efficacy and safety of combined intrathecal morphine (ITM) and epidural analgesia (EPI) to that of conventional intravenous patient-controlled analgesia (IV-PCA) after posterior spinal fusion (PSF) for adolescent idiopathic scoliosis (AIS). Pain control after PSF in AIS has been managed traditionally with IV-PCA. More recently studies have shown improvement in pain control with the use of continuous EPI or intraoperative ITM. No studies to our knowledge have compared the use of both ITM and EPI analgesia to that of IV-PCA. An Institutional Review Board-approved retrospective case-comparison study was performed from 1989 to 2009 of all patients undergoing PSF for AIS. Patients received either IV-PCA or ITM/EPI. Daily pain scores were recorded along with total opioid and benzodiazepine use. Adverse events were recorded for all the patients. A total of 146 patients were initially included in the study; 95 patients received ITM/EPI and 51 received IV-PCA as a historical control. Eight patients from the ITM/EPI group were excluded from the pain comparison portion of the study. There were no statistical differences in age, sex, weight, or hospital stay between the 2 groups. The ITM/EPI group had, on average, 1 additional level of fusion (P = 0.001). Daily average pain scores were lower in the ITM/EPI group on all hospital days, and statistically lower in days 1 and 3 to 5. Total opioid requirement was significantly lower in the ITM/EPI patients, although oral opioid use was higher among this group. Total benzodiazepine use was lower among the IV-PCA group. A total of 15.7% of the IV-PCA patients had bladder hypotonia, compared with 1.1% of the ITM/EPI group (P = 0.002). The rate of illeus was 15.7% in the IV-PCA patients and 5.7% in the ITM/EPI (P = 0.071). Respiratory depression was reported in 4 ITM/EPI patients, 0 in our PCA group. Technical catheter malfunction was reported in 8.5% of the EPI group. The use of ITM

  15. Camp Health Aide Manual = Manual para trabajadores de salud.

    Science.gov (United States)

    Robinson, June Grube; And Others

    This bilingual manual serves as a textbook for migrant Camp Health Aides. Camp Health Aides are members of migrant labor camps enlisted to provide information about health and social services to migrant workers and their families. The manual is divided into 12 tabbed sections representing lessons. Teaching notes printed on contrasting paper…

  16. Effects of injectable trace mineral supplementation in lactating dairy cows with elevated somatic cell counts.

    Science.gov (United States)

    Ganda, E K; Bisinotto, R S; Vasquez, A K; Teixeira, A G V; Machado, V S; Foditsch, C; Bicalho, M; Lima, F S; Stephens, L; Gomes, M S; Dias, J M; Bicalho, R C

    2016-09-01

    Objectives of this clinical trial were to evaluate the effects of injectable trace mineral supplementation (ITMS) on somatic cell count (SCC), linear score (LS), milk yield, milk fat and protein contents, subclinical mastitis cure, and incidence of clinical mastitis in cows with elevated SCC. Holstein cows from a commercial dairy farm in New York were evaluated for subclinical mastitis, defined as SCC ≥200×10(3) cells/mL on the test day preceding enrollment. Cows with a history of treatment for clinical mastitis in the current lactation and those pregnant for more than 150d were not eligible for enrollment. Cows fitting inclusion criteria were randomly allocated to 1 of 2 treatment groups. Cows assigned to ITMS (n=306) received 1 subcutaneous injection containing zinc (300mg), manganese (50mg), selenium (25mg), and copper (75mg) at enrollment (d 0). Control cows (CTRL; n=314) received 1 subcutaneous injection of sterile saline solution. Following treatment, visual assessment of milk was performed daily, and cows with abnormal milk (i.e., presence of flakes, clots, or serous milk) were diagnosed with clinical mastitis (CM). Chronic clinical mastitis was defined as cows with 3 or more cases of CM. Milk yield, milk fat and protein contents, SCC, and LS were evaluated once monthly. Additionally, randomly selected animals were sampled to test serum concentrations of selected minerals on d0 and 30 (n=30 cows/treatment). Treatment did not affect serum concentrations of calcium, magnesium, phosphorus, potassium, copper, iron, manganese, selenium, and zinc on d30. Injectable supplementation with trace minerals did not improve overall cure of subclinical mastitis (CTRL=42.8 vs. ITMS=46.5%), although a tendency was observed in cows with 3 or more lactations (CTRL=27.1 vs. ITMS=40.0%). Supplementation did not reduce treatment incidence of CM (CTRL=48.2 vs. ITMS=41.7%); however, it tended to reduce the proportion of cows diagnosed with chronic CM (CTRL=16.9 vs. ITMS=12

  17. Manual Therapy With Cryotherapy Versus Manual Therapy With Kinesio Taping for Males With Lumbar Discopathy: A Pilot Randomized Trial.

    Science.gov (United States)

    Lizis, Pawel; Kobza, Wojciech

    2017-06-23

    Context • Numerous modalities of therapeutic interventions exist for lumbar discopathy. Manual therapy is one option, although its effectiveness remains controversial. The addition of cryotherapy to manual therapy may enhance the health benefits in patients with lumbar discopathy.  Objective • The study intended to evaluate the efficacy of manual therapy combined with cryotherapy vs manual therapy combined with Kinesio taping for males with lumbar discopathy. Design • The research team designed a pilot randomized trial with concealed allocation, assessor blinding, and intention-to-treat analysis. Setting • The study occurred in the Physiotherapy Outpatient Department of the Regional Hospital (Zywiec, Poland). Participants • The participants were 40 males with lumbar discopathy, aged 30-75 y, who were patients in the department at the hospital. Intervention • The participants were randomly assigned to an intervention group that received Kaltenborn-Evjenth orthopedic manual therapy (KEOMT) combined with cryotherapy, the KEOMT-C group (n = 20), or to a control group that received KEOMT combined with Kinesio taping, the KEOMT-K group (n = 20). The participants in both groups received 10 treatments, 2 per wk for 5 wk. Outcome Measures • The primary outcome was measured using a visual analog scale and the Laitinen scale pain ratings. The secondary outcome measured the quality of life using the short form-36 questionnaire. The participants completed the tests at baseline and postintervention. Results • After the treatments, the intervention group had significantly lower scores than the control group for pain as well as significantly higher scores for quality of life. Conclusions • Patients achieved better health benefits from manual therapy when it was combined with cryotherapy.

  18. Program user's manual: cryogen system for the analysis for the Mirror Fusion Test Facility

    International Nuclear Information System (INIS)

    1979-04-01

    The Mirror Fusion Test Facility being designed and constructed at the Lawrence Livermore Laboratory requires a liquid helium liquefaction, storage, distribution, and recovery system and a liquid nitrogen storage and distribution system. To provide a powerful analytical tool to aid in the design evolution of this system through hardware, a thermodynamic fluid flow model was developed. This model allows the Lawrence Livermore Laboratory to verify that the design meets desired goals and to play what if games during the design evolution. For example, what if the helium flow rate is changed in the magnet liquid helium flow loop; how does this affect the temperature, fluid quality, and pressure. This manual provides all the information required to run all or portions of this program as desired. In addition, the program is constructed in a modular fashion so changes or modifications can be made easily to keep up with the evolving design

  19. Development of an in vitro laboratory manual for nuclear medicine technology students

    International Nuclear Information System (INIS)

    Meyers, A.

    1989-01-01

    This study evaluated existing in vitro education materials in qualitative and quantitative parameters that currently exist to educate potential clinicians of nationally accredited nuclear medicine programs. A review of over 300 articles, texts, and manuals pertaining to in vitro nuclear medicine procedures clearly demonstrated that no in vitro laboratory manual for undergraduate students presently exited. Every nuclear medicine program director in the United States was surveyed. They were asked for their overall philosophy in terms of developing an in vitro manual and requested to evaluate the significant of 22 general principles/concepts and 34 specific laboratory testing procedures. From the response to the survey, an in vitro nuclear medicine manual was created and appended to the study. The manual consists of lecture and study material, chapter reviews, and laboratory assignments and exercises

  20. Dounreay Shuffler diagnostic software operations manual

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Stuewe, B.; Klosterbuer, S.; Van Lyssel, T.

    1985-07-01

    This operations manual describes the test software for the Dounreay Shuffler. The Shuffler is an assay system, controlled by a Commodore PET computer, that measures the plutonium content in leached hulls at the fuel reprocessing plant in Dounreay, Scotland. The Shuffler contains a 252 Cf neutron source that is moved between storage and irradiation locations to obtain measurement data. A stepping motor control (SMC) module operates the Shuffler and accepts commands from the PET to move the source. This manual briefly describes the Shuffler and provides details on running and using the diagnostic software program. The communications protocol for message transmittal between the PET and SMC is defined and a detailed example of message sending is presented in an appendix

  1. Manual therapy treatment of lumbar radiculopathy: A single case report

    Directory of Open Access Journals (Sweden)

    J.A. Riley

    2011-01-01

    Full Text Available Patients  with  lumbar  radiculopathy  are  often  managed with  manual therapy.  The  aim  of  this  single  case  study  was  to  describe  the outcome of manual therapy treatment of a patient with lumbar radiculopathy.  A 47-year-old female presented with acute, severe left buttock and postero-lateral thigh pain.  Symptom provocation occurred during lumbar flexion, coughing, sneezing, driving and prolonged sitting. her left straight leg raise neurodynamic test was limited and reproduced her pain, as did trigger points in the left lumbar and gluteal muscles. clinical neuro-conduction testing revealed weakness of the big and other toe extensors, as well as eversion and plantar flexion of the left ankle, and a diminished left ankle reflex. This indicated possible involvement of both the l5 and S1 nerve roots.   A  manual  therapy  treatment  approach including  lumbar rotation mobilisations (Maitland approach, massage, trigger point pressure release  and  Transversus  Abdominus muscle activation  was  used.   The  patient  was  symptom  free,  had  full pain-free  range  of  all  lumbar  movements,  a full  pain-free  left  straight leg  raise  neurodynamic  test  and  normal  neurological  conduction  six weeks  after  onset, following seven manual therapy treatments.  Although the results of this case report cannot be generalised, it describes the successful outcome of a patient with severe radicular pain and neurological deficits, whose signs and symptoms  had completely resolved following manual therapy treatment.

  2. A Manual of Style.

    Science.gov (United States)

    Nebraska State Dept. of Education, Lincoln.

    This "Manual of Style" is offered as a guide to assist Nebraska State employees in producing quality written communications and in presenting a consistently professional image of government documents. The manual is not designed to be all-inclusive. Sections of the manual discuss formatting documents, memorandums, letters, mailing…

  3. Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.

    Science.gov (United States)

    Kolokitha, Olga-Elpis

    2007-10-01

    The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.

  4. A universal access layer for the Integrated Tokamak Modelling Task Force

    International Nuclear Information System (INIS)

    Manduchi, G.; Iannone, F.; Imbeaux, F.; Huysmans, G.; Lister, J.B.; Guillerminet, B.; Strand, P.; Eriksson, L.-G.; Romanelli, M.

    2008-01-01

    The Integrated Tokamak Modelling (ITM) Task Force aims at providing a suite of codes for preparing and analyzing future ITER discharges. In the framework of the ITM, the universal access layer (UAL) provides the capability of storing and retrieving data involved in simulation. The underlying data structure is hierarchical and the granularity in data access is given by the definition of a set of consistent physical objects (CPOs). To describe the data structure of the overall ITM database, the XML schema description (XSD) has been used. Originally intended to describe the structure of XML documents, XSD is used here to provide an unambiguous way of describing how data are structured, regardless of the actual implementation of the underlying database. The MDSplus-based UAL implementation is currently under test and other prototypes for investigating alternative data storage systems are foreseen

  5. MARS CODE MANUAL VOLUME III - Programmer's Manual

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Hwang, Moon Kyu; Jeong, Jae Jun; Kim, Kyung Doo; Bae, Sung Won; Lee, Young Jin; Lee, Won Jae

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This programmer's manual provides a complete list of overall information of code structure and input/output function of MARS. In addition, brief descriptions for each subroutine and major variables used in MARS are also included in this report, so that this report would be very useful for the code maintenance. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  6. Quality Manual

    Science.gov (United States)

    Koch, Michael

    The quality manual is the “heart” of every management system related to quality. Quality assurance in analytical laboratories is most frequently linked with ISO/IEC 17025, which lists the standard requirements for a quality manual. In this chapter examples are used to demonstrate, how these requirements can be met. But, certainly, there are many other ways to do this.

  7. User Manual for SSG Power Simulation 2

    DEFF Research Database (Denmark)

    Jensen, Palle Meinert; Gilling, Lasse; Kofoed, Jens Peter

    This manual gives a detailed description of the use of the computer program SSG Power Simulation 2. Furthermore, the underlying mathematics and algorithms are briefly described. The program is based on experimental data from model testing of Seawave Slot-Cone Generator (SSG) presented in Kofoed...

  8. Diagnóstico laboratorial da anemia hemolítica auto-imune: características do teste manual direto do PolybreneÒ Laboratory diagnosis of auto-immune hemolytic anemia: characteristics of the manual direct test of PolybreneTM

    Directory of Open Access Journals (Sweden)

    G.W. Braga

    1998-03-01

    Full Text Available O teste manual direto do PolybreneÒ (TDP e o teste de Coombs direto (TCD foram utilizados para a detecção de IgG na superfície de hemácias de pacientes com diagnóstico clínico e laboratorial de anemia hemolítica auto-imune (AHAI. OBJETIVO: Comparar a sensibilidade e especificidade do TPD e do TCD no diagnóstico da AHAI. MÉTODO: Foram estudados 18 pacientes com diagnóstico clínico-laboratorial de AHAI. Como indivíduos controles, foram testados 20 doadores de sangue assintomáticos e 20 pacientes com anemia falciforme. RESULTADOS: O TCD foi positivo em 14 pacientes e negativo em quatro indivíduos, enquanto o TDP foi positivo em 17 pacientes e negativo em um indivíduo que apresentava TCD positivo devido a fixação de complemento (C3d nas hemácias. Todos os eluatos positivos realizados com a técnica de diclorometano revelaram anticorpos quentes com especificidade "anti-Rh". A sensibilidade do TDP (94% para detectar fixação de IgG in vivo foi significantemente maior (pThe direct manual PolybreneTM test (DPT and the direct antiglobulin tests (DAT were employed to detect antibody sensitizing red blood cell (RCB in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA. PURPOSE: To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. METHODS: Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents ( anti-IgG heavy chain and anti-C3d. Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM. RESULTS: The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d. All

  9. Training Of Manual Actions Improves Language Understanding of Semantically-Related Action Sentences

    Directory of Open Access Journals (Sweden)

    Matteo eLocatelli

    2012-12-01

    Full Text Available Conceptual knowledge accessed by language may involve the re-activation of the associated primary sensory-motor processes. Whether these embodied representations are indeed constitutive to conceptual knowledge is hotly debated, particularly since direct evidence that sensory-motor expertise can improve conceptual processing is scarce.In this study, we sought for this crucial piece of evidence, by training naive healthy subjects to perform complex manual actions and by measuring, before and after training, their performance in a semantic language task. 19 participants engaged in 3 weeks of motor training. Each participant was trained in 3 complex manual actions (e.g. origami. Before and after the training period, each subject underwent a series of manual dexterity tests and a semantic language task. The latter consisted of a sentence-picture semantic congruency judgment task, with 6 target congruent sentence-picture pairs (semantically related to the trained manual actions, 6 non-target congruent pairs (semantically unrelated, and 12 filler incongruent pairs.Manual action training induced a significant improvement in all manual dexterity tests, demonstrating the successful acquisition of sensory-motor expertise. In the semantic language task, the reaction times to both target and non-target congruent sentence-image pairs decreased after action training, indicating a more efficient conceptual-semantic processing. Noteworthy, the reaction times for target pairs decreased more than those for non-target pairs, as indicated by the 2x2 interaction. These results were confirmed when controlling for the potential bias of increased frequency of use of target lexical items during manual training.The results of the present study suggest that sensory-motor expertise gained by training of specific manual actions can lead to an improvement of cognitive-linguistic skills related to the specific conceptual-semantic domain associated to the trained actions.

  10. Logic and discrete mathematics a concise introduction : solutions manual

    CERN Document Server

    Conradie, Willem; Robinson, Claudette

    2015-01-01

    Solutions manual to accompany Logic and Discrete Mathematics: A Concise Introduction This book features a unique combination of comprehensive coverage of logic with a solid exposition of the most important fields of discrete mathematics, presenting material that has been tested and refined by the authors in university courses taught over more than a decade. Written in a clear and reader-friendly style, each section ends with an extensive set of exercises, most of them provided with complete solutions which are available in this accompanying solutions manual.

  11. User manual for Blossom statistical package for R

    Science.gov (United States)

    Talbert, Marian; Cade, Brian S.

    2005-01-01

    Blossom is an R package with functions for making statistical comparisons with distance-function based permutation tests developed by P.W. Mielke, Jr. and colleagues at Colorado State University (Mielke and Berry, 2001) and for testing parameters estimated in linear models with permutation procedures developed by B. S. Cade and colleagues at the Fort Collins Science Center, U.S. Geological Survey. This manual is intended to provide identical documentation of the statistical methods and interpretations as the manual by Cade and Richards (2005) does for the original Fortran program, but with changes made with respect to command inputs and outputs to reflect the new implementation as a package for R (R Development Core Team, 2012). This implementation in R has allowed for numerous improvements not supported by the Cade and Richards (2005) Fortran implementation, including use of categorical predictor variables in most routines.

  12. Fuel Element Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Burley, H.H. [ed.

    1956-08-01

    It is the purpose of the Fuel Element Technical Manual to Provide a single document describing the fabrication processes used in the manufacture of the fuel element as well as the technical bases for these processes. The manual will be instrumental in the indoctrination of personnel new to the field and will provide a single data reference for all personnel involved in the design or manufacture of the fuel element. The material contained in this manual was assembled by members of the Engineering Department and the Manufacturing Department at the Hanford Atomic Products Operation between the dates October, 1955 and June, 1956. Arrangement of the manual. The manual is divided into six parts: Part I--introduction; Part II--technical bases; Part III--process; Part IV--plant and equipment; Part V--process control and improvement; and VI--safety.

  13. [Manual lifting and manual transport: risk assessment and prevalence of work-related diseases in construction companies in Basilicata].

    Science.gov (United States)

    Nicoletti, S; Battevi, N; Colafemmina, G; Di Leone, G; Satriani, G; Ragone, P; Occhipinti, E

    2013-01-01

    The Basilicata Regional Headquarters of the Italian Institute for Insurance against Occupational Accidents and Disease (INAIL) and the Basilicata association of small building enterprises (Edilcassa di Basilicata) promoted a research project to assess the risk of manual lifting and manual transport in construction enterprises in the Basilicata Region and estimate the prevalence of related diseases. Manual lifting risk assessment was performed by calculating the VLI of 204 working days in as many building workers. Manual transport risk assessment was carried out comparing the weights transported (on the 204 days tested) with the reference values of the "Snoock and Ciriello" tables. Manual Ifting risk was present on 195 of the 204 days, with an average value of VLI equal to 2.1 (min 0.4, max 8.5), with higher values in the restructuring sector (VLI average of 2.3, min 0.4, max 8.5), and no significant differences between the different tasks. Manual transport risk was present on 129 of the 204 days, with average values of 1.2 (min 0.2, max 3.3), with no significant differences between the different tasks analyzed For both risks additional factors were present that were not analyzed by the methods of assessment used (for manual lifting: 8.8% of the geometries in the critical area; for manual transport: 39% of transport on shoulders, 42.5% on a route with uneven surface and 31.9% on a sloping route), so it is likely that the actual risk is greater than that indicated by the synthetic indices of exposure. The medical questionnaire showed from the case histories that 148 out of 546 subjects were positive for the threshold forpain or discomfort in the lumbosacral spine area and 99 out of 546 subjects reported suffering from an already diagnosed herniated spinal disk. Only 18% of osteoarticular diseases was reported to the Insurance Institute, al though there was widespread awareness that the diseases in question might be related to work. Diseases of the spine were

  14. WISDAAM software programmer's manual

    International Nuclear Information System (INIS)

    Ball, J.R.

    1992-10-01

    The WISDAAM system was developed to provide quality control over test data associated with in situ testing at the Waste Isolation Pilot Plant (WIPP). Assurance of data quality is of critical importance as these tests supply the information which will be used for development and verification of the technology required for repository implementation. The amount of data collected from the tests, which are some of the largest ever fielded in an underground facility, prompted the undertaking of a major project task to address data processing. The goal was to create a conceptual umbrella under which all of the activities associated with processing WIPP data (i.e., data reduction, archiving, retrieval, etc.) could be grouped. The WISDAAM system was the product of this task. The overall system covers electronic as well as manual data processing; however, this document deals primarily with those operations implemented by software running on a VAX computer

  15. Mathematics Competency Test: User's Manual.

    Science.gov (United States)

    Vernon, P. E.; And Others

    The Mathematics Competency Test is a 46-question written test assessing mathematics achievement for groups or individuals aged 11 to adult. It is suitable for use with groups or individuals in school, college and workplace contexts. The questions are open-ended and require constructed responses rather than recognition of a correct answer in a…

  16. Lumbar segmental instability: a criterion-related validity study of manual therapy assessment

    Directory of Open Access Journals (Sweden)

    Chapple Cathy

    2005-11-01

    Full Text Available Abstract Background Musculoskeletal physiotherapists routinely assess lumbar segmental motion during the clinical examination of a patient with low back pain. The validity of manual assessment of segmental motion has not, however, been adequately investigated. Methods In this prospective, multi-centre, pragmatic, diagnostic validity study, 138 consecutive patients with recurrent or chronic low back pain (R/CLBP were recruited. Physiotherapists with post-graduate training in manual therapy performed passive accessory intervertebral motion tests (PAIVMs and passive physiological intervertebral motion tests (PPIVMs. Consenting patients were referred for flexion-extension radiographs. Sagittal angular rotation and sagittal translation of each lumbar spinal motion segment was measured from these radiographs, and compared to a reference range derived from a study of 30 asymptomatic volunteers. Motion beyond two standard deviations from the reference mean was considered diagnostic of rotational lumbar segmental instability (LSI and translational LSI. Accuracy and validity of the clinical assessments were expressed using sensitivity, specificity, and likelihood ratio statistics with 95% confidence intervals (CI. Results Only translation LSI was found to be significantly associated with R/CLBP (p Conclusion This study provides the first evidence reporting the concurrent validity of manual tests for the detection of abnormal sagittal planar motion. PAIVMs and PPIVMs are highly specific, but not sensitive, for the detection of translation LSI. Likelihood ratios resulting from positive test results were only moderate. This research indicates that manual clinical examination procedures have moderate validity for detecting segmental motion abnormality.

  17. CONCIENTIZACIÓN AMBIENTAL SOBRE LOS GEI Y EL CAMBIO CLIMÁTICO EN EL INSTITUTO TECNOLÓGICO METROPOLITANO, INSTITUCIÓN UNIVERSITARIA (ITM

    Directory of Open Access Journals (Sweden)

    Sergio E. Arango Osorno

    2014-05-01

    Full Text Available La preocupación actual por las notables evidencias del cambio climático global está llevando a los países a mitigar sus principales causas: los gases efecto invernadero (GEI, a través de diferentes estrategias, entre ellas y haciendo un gran énfasis esta la educación ambiental.  La huella de carbono es un indicador del impacto ambiental sobre la atmósfera, que cuantifica las diferentes emisiones de GEI, que se pueden estimar de manera aproximada haciendo uso de los aplicativos disponibles en la web. Se presentan en el presente artículo las principales campañas de educación ambiental y experiencias desarrolladas por el semillero de cultura, gestión e investigación ambiental “Cuida Tu Huella”, con relación a la Huella de  Carbono en el Instituto Tecnológico Metropolitano (ITM. La estimación de la huella de carbono personal arrojó resultados de 4.22 y 3.87 ton CO2/año para los años 2011 y 2012 respectivamente, siendo aún más importante el impacto que se ha podido lograr en la comunidad académica, que trasciende el espacio geográfico de la Institución, ya que ha permitido lograr la concientización en cuanto a identificar las diferentes actividades que más producen GEI, transformando así los hábitos de vida por otros más ambientalmente sostenibles.

  18. Radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP.

  19. Radiological control manual. Revision 1

    International Nuclear Information System (INIS)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP

  20. Manual muscle testing: a method of measuring extremity muscle strength applied to critically ill patients.

    Science.gov (United States)

    Ciesla, Nancy; Dinglas, Victor; Fan, Eddy; Kho, Michelle; Kuramoto, Jill; Needham, Dale

    2011-04-12

    Survivors of acute respiratory distress syndrome (ARDS) and other causes of critical illness often have generalized weakness, reduced exercise tolerance, and persistent nerve and muscle impairments after hospital discharge. Using an explicit protocol with a structured approach to training and quality assurance of research staff, manual muscle testing (MMT) is a highly reliable method for assessing strength, using a standardized clinical examination, for patients following ARDS, and can be completed with mechanically ventilated patients who can tolerate sitting upright in bed and are able to follow two-step commands. (7, 8) This video demonstrates a protocol for MMT, which has been taught to ≥ 43 research staff who have performed >800 assessments on >280 ARDS survivors. Modifications for the bedridden patient are included. Each muscle is tested with specific techniques for positioning, stabilization, resistance, and palpation for each score of the 6-point ordinal Medical Research Council scale. Three upper and three lower extremity muscles are graded in this protocol: shoulder abduction, elbow flexion, wrist extension, hip flexion, knee extension, and ankle dorsiflexion. These muscles were chosen based on the standard approach for evaluating patients for ICU-acquired weakness used in prior publications. (1,2).

  1. CRISP instrument manual

    International Nuclear Information System (INIS)

    Bucknall, D.G.; Langridge, Sean

    1997-05-01

    This document is a user manual for CRISP, one of the two neutron reflectomers at ISIS. CRISP is highly automated allowing precision reproducible measurements. The manual provides detailed instructions for the setting-up and running of the instrument and advice on data analysis. (UK)

  2. Salinas : theory manual.

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Timothy Francis; Reese, Garth M.; Bhardwaj, Manoj Kumar

    2004-08-01

    This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas , we refer the reader to Salinas, User's Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programer-notes manual, the user's notes and of course the material in the open literature.

  3. PCs The Missing Manual

    CERN Document Server

    Karp, David

    2005-01-01

    Your vacuum comes with one. Even your blender comes with one. But your PC--something that costs a whole lot more and is likely to be used daily and for tasks of far greater importance and complexity--doesn't come with a printed manual. Thankfully, that's not a problem any longer: PCs: The Missing Manual explains everything you need to know about PCs, both inside and out, and how to keep them running smoothly and working the way you want them to work. A complete PC manual for both beginners and power users, PCs: The Missing Manual has something for everyone. PC novices will appreciate the una

  4. Effects of bedding systems selected by manual muscle testing on sleep and sleep-related respiratory disturbances.

    Science.gov (United States)

    Tsai, Ling-Ling; Liu, Hau-Min

    2008-03-01

    In this study, we investigated the feasibility of applying manual muscle testing (MMT) for bedding selection and examined the bedding effect on sleep. Four lay testers with limited training in MMT performed muscle tests for the selection of the bedding systems from five different mattresses and eight different pillows for 14 participants with mild sleep-related respiratory disturbances. For each participant individually, two bedding systems-one inducing stronger muscle forces and the other inducing weaker forces-were selected. The tester-participant pairs showed 85% and 100% agreement, respectively, for the selection of mattresses and pillows that induced the strongest muscle forces. The firmness of the mattress and the height of the pillow were significantly correlated with the body weight and body mass index of the participants for the selected strong bedding system but not for the weak bedding system. Finally, differences were observed between the strong and the weak bedding systems with regard to sleep-related respiratory disturbances and the percentage of slow-wave sleep. It was concluded that MMT can be performed by inexperienced testers for the selection of bedding systems.

  5. Operation manual for the core flow test loop zone power-supply controller

    Energy Technology Data Exchange (ETDEWEB)

    Harper, R.E.

    1981-11-01

    The core flow test loop, which is part of the Gas-Cooled Fast Breeder Reactor Program (GCFR) at ORNL, is a high-pressure, high-temperature, out-of-reactor helium circulation system that is being constructed to permit study of the performance at steady-state and transient conditions of simulated segments of core assemblies for a GCFR demonstration plant. The simulated core segments, which are divided into zones, contain electrical heating elements to simulate the heat generated by fission. To control the power which is applied to a zone, a novel multitapped transformer and zone power control system have been designed and built which satisfy stringent design criteria. The controller can match power output to demand to within better than +-1% over a 900:1 dynamic range and perform full-power transients within 1 s. The power is applied in such a way as to minimize the electromagnetic interference at the bandwidth of the loop instrumentation, and the controller incorporates several error detection techniques, making it inherently fail-safe. The operation manual describes the specifications, operating instructions, error detection capabilities, error recovery, troubleshooting, calibration and QA procedures, and maintenance requirements. Also included are sections on the theory of operation, circuitry description, and a complete set of schematics.

  6. European correlation counter (ECC) VER. 1.0 users manual

    International Nuclear Information System (INIS)

    Vocino, V.

    1989-01-01

    The users manual is conceived for the utilization of personal computers linked to a shift register for the assay of Pu containing fuel. It is based on an MS DOS system and permits the users to store calibration curves, constants, measurement and assay data on floppy disks for ulterior utilisation. The interpretation models use the latest theories of neutron multiplication and dead time effects. The inspector is guided by the screen display step by step from the instrument test via calibration to the assay and data storage. All test, calibration and assay data can be printed out on paper tape and serve to the inspector to prepare the respective inspection report. The users are invited to make suggestions to the authors, such that the manual's use can be adapted to further requirements

  7. Tracer manual on crops and soils

    International Nuclear Information System (INIS)

    1976-01-01

    The manual serves as a reference for agricultural scientists planning to use nuclear techniques. Training courses are held at various locations with different staff. The existence of a laboratory training manual is helpful to organizers, visiting lecturers, demonstrators and participants. It was primarily written for soil scientists from developing countries participating in training courses on the use of isotopes and radiation in soil-water-plant relations research. The training courses are designed to give soil scientists the basic terms and principles necessary for understanding ionizing radiation, its detection and measurement, its associated hazards and most of the more common applications. Due consideration is also given to the detection of stable isotopes and providing a clear understanding of their potential in research on crops and soils. Each experiment included this revised and updated manual (see IAEA Technical Reports Series No. 29: The Laboratory Training Manual on the Use of Isotopes and Radiation in Soil-Plant Relations Research, published in 1964) has been performed and tested for suitability in training courses. To facilitate the task of organizers in preparing for and planning the programmes of training courses, detailed information is provided on each experiment, indicating the time required for its performance and the necessary equipment, glassware, isotopes, chemicals, etc. A comprehensive glossary is included so that scientists may easily understand terms, units and expressions commonly used in this work. The glossary may also serve as an index since it includes the page number referring to the first mention of the term or expression

  8. An Instrumented Glove to Assess Manual Dexterity in Simulation-Based Neurosurgical Education

    Directory of Open Access Journals (Sweden)

    Juan Diego Lemos

    2017-04-01

    Full Text Available The traditional neurosurgical apprenticeship scheme includes the assessment of trainee’s manual skills carried out by experienced surgeons. However, the introduction of surgical simulation technology presents a new paradigm where residents can refine surgical techniques on a simulator before putting them into practice in real patients. Unfortunately, in this new scheme, an experienced surgeon will not always be available to evaluate trainee’s performance. For this reason, it is necessary to develop automatic mechanisms to estimate metrics for assessing manual dexterity in a quantitative way. Authors have proposed some hardware-software approaches to evaluate manual dexterity on surgical simulators. This paper presents IGlove, a wearable device that uses inertial sensors embedded on an elastic glove to capture hand movements. Metrics to assess manual dexterity are estimated from sensors signals using data processing and information analysis algorithms. It has been designed to be used with a neurosurgical simulator called Daubara NS Trainer, but can be easily adapted to another benchtop- and manikin-based medical simulators. The system was tested with a sample of 14 volunteers who performed a test that was designed to simultaneously evaluate their fine motor skills and the IGlove’s functionalities. Metrics obtained by each of the participants are presented as results in this work; it is also shown how these metrics are used to automatically evaluate the level of manual dexterity of each volunteer.

  9. Relationship between manual dexterity and the unified parkinson's disease rating scale-motor exam.

    Science.gov (United States)

    Hwang, Sujin; Song, Chiang-Soon

    2016-12-01

    [Purpose] The purpose of this study was to examine the relationships between manual dexterity and the Unified Parkinson's Disease Rating Scale-Motor Exam as a clinical tool for quantifying upper extremity function in persons with Parkinson's disease. [Subjects and Methods] Thirty-two persons with idiopathic Parkinson's disease participated in this study. This study measured two clinical outcomes, the box-and-block test and the Unified Parkinson's Disease Rating Scale-Motor Exam, to investigate the relationships between manual dexterity and the Unified Parkinson's Disease Rating Scale-Motor Exam. [Results] The box-and-block test on the more affected side was positive relationship with the box-and-block test on the less affected side. The Unified Parkinson's Disease Rating Scale-motor exam score had a negative correlation with the box-and-block test results for both sides. [Conclusion] A positive association was noted between manual dexterity and motor function in patients with idiopathic Parkinson disease. The results of this study suggest that the box-and-block test and the Unified Parkinson's Disease Rating Scale-Motor Exam are good clinical measures that quantify upper extremity function and are necessary for the accurate evaluation of patients and to plan intervention strategies.

  10. Eco-Innovation Manual

    DEFF Research Database (Denmark)

    O'Hare, Jamie Alexander; McAloone, Tim C.; Pigosso, Daniela Cristina Antelmi

    Aim of this manual is to introduce a methodology for the implementation of eco‐innovation within small and medium sized companies in developing and emerging economies. The intended audience of this manual is organizations that provide professional services to guide and support manufacturing compa...... companies to improve their sustainability performance....

  11. Astronaut training manual

    Science.gov (United States)

    Coleman, E. A.

    1980-01-01

    Scientific information from previous space flights, space medicine, exercise physiology, and sports medicine was used to prepare a physical fitness manual suitable for use by members of the NASA astronaut population. A variety of scientifically valid exercise programs and activities suitable for the development of physical fitness are provided. Programs, activities, and supportive scientific data are presented in a concise, easy to read format so as to permit the user to select his or her mode of training with confidence and devote time previously spent experimenting with training routines to preparation for space flight. The programs and activities included were tested and shown to be effective and enjoyable.

  12. Users' Manual for Research: Translating Head Start Findings Into Action (Expanded Notebook Version).

    Science.gov (United States)

    Grotberg, Edith H.; Fowler, Austine

    This users' manual, intended for use with a Project Head Start teacher training notebook, describes the purpose, development and field testing of the training materials and suggests procedures for using the notebook as a resource in teacher training sessions. The training notebook to which the users' manual refers is based on 11 questions in the…

  13. Do treatment manuals undermine youth–therapist alliance in community clinical practice?

    OpenAIRE

    Langer, David A.; McLeod, Bryce D.; Weisz, John R

    2011-01-01

    Objective: Some critics of treatment manuals have argued that their use may undermine the quality of the client–therapist alliance. This notion was tested in the context of youth psychotherapy delivered by therapists in community clinics. Method: Seventy-six clinically referred youths (57% female, age 8–15 years, 34% Caucasian) were randomly assigned to receive nonmanualized usual care or manual-guided treatment to address anxiety or depressive disorders. Treatment was provided in community c...

  14. FINAS. Example manual. 2

    International Nuclear Information System (INIS)

    Iwata, Koji; Tsukimori, Kazuyuki; Ueno, Mutsuo

    2003-12-01

    FINAS is a general purpose structural analysis computer program which was developed by Japan Nuclear Cycle Development Institute for the analysis of static, dynamic and thermal responses of elastic and inelastic structures by the finite element method. This manual contains typical analysis examples that illustrate applications of FINAS to a variety of structural engineering problems. The first part of this manual presents fundamental examples in which numerical solutions by FINAS are compared with some analytical reference solutions, and the second part of this manual presents more complex examples intended for practical application. All the input data images and principal results for each problem are included in this manual for beginners' convenience. All the analyses are performed by using the FINAS Version 13.0. (author)

  15. TRANSWRAP II: problem definition manual

    International Nuclear Information System (INIS)

    Knittle, D.E.

    1981-02-01

    The TRANSWRAP II computer code, written in Fortran IV and described in this Problem Definition Manual, was developed to analytically predict the magnitude of pressure pulses of large scale sodium-wate reactions in LMFBR secondary systems. It is currently being used for the Clinch River Breeder Reactor Program. The code provides the options, flexibility and features necessary to consider any system configuration. The code methodology has been validated with the aid of extensive sodium-water reaction test programs

  16. The Interactive Electronic Technical Manual: Requirements, Current Status, and Implementation. Strategy Considerations.

    Science.gov (United States)

    1991-07-01

    authoring systems. Concurrently, great strides in computer-aided design and computer-aided maintenance have contributed to this capability. 12 Junod ...J.; William A. Nugent; and L. John Junod . Plan for the Navy/Air Force Test of the Interactive Electronic Technical Manual (IETM) at Cecil Field...AFHRL Logistics and Human Factors Division, WPAFB. Aug 1990. 12. Junod , John L. PY90 Interactive Electronic Technical Manual (IETM) Portable Delivery

  17. Biosafety Manual

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce W.

    2010-05-18

    Work with or potential exposure to biological materials in the course of performing research or other work activities at Lawrence Berkeley National Laboratory (LBNL) must be conducted in a safe, ethical, environmentally sound, and compliant manner. Work must be conducted in accordance with established biosafety standards, the principles and functions of Integrated Safety Management (ISM), this Biosafety Manual, Chapter 26 (Biosafety) of the Health and Safety Manual (PUB-3000), and applicable standards and LBNL policies. The purpose of the Biosafety Program is to protect workers, the public, agriculture, and the environment from exposure to biological agents or materials that may cause disease or other detrimental effects in humans, animals, or plants. This manual provides workers; line management; Environment, Health, and Safety (EH&S) Division staff; Institutional Biosafety Committee (IBC) members; and others with a comprehensive overview of biosafety principles, requirements from biosafety standards, and measures needed to control biological risks in work activities and facilities at LBNL.

  18. Dissociated effects of distractors on saccades and manual aiming.

    Science.gov (United States)

    McIntosh, Robert D; Buonocore, Antimo

    2012-08-01

    The remote distractor effect (RDE) is a robust phenomenon whereby target-directed saccades are delayed by the appearance of a distractor. This effect persists even when the target location is perfectly predictable. The RDE has been studied extensively in the oculomotor domain but it is unknown whether it generalises to other spatially oriented responses. In three experiments, we tested whether the RDE generalises to manual aiming. Experiment 1 required participants to move their hand or eyes to predictable targets presented alone or accompanied by a distractor in the opposite hemifield. The RDE was observed for the eyes but not for the hand. Experiment 2 replicated this dissociation in a more naturalistic task in which eye movements were not constrained during manual aiming. Experiment 3 confirmed the lack of manual RDE across a wider range of distractor delays (0, 50, 100, and 150 ms). Our data imply that the RDE is specific to the oculomotor system, at least for non-foveal distractors. We suggest that the oculomotor RDE reflects competitive interactions between target and distractor representations in the superior colliculus, which are not necessarily shared by manual aiming.

  19. Liquid penetrant and magnetic particle testing at level 2. Manual for the syllabi contained in IAEA-TECDOC-628, training guidelines in non-destructive testing techniques

    International Nuclear Information System (INIS)

    2000-01-01

    specifications; be able to train and supervise the Level 1 staff under them and organize and report NDT results. The next logical step is to compile the textbooks and training manuals in accordance with these syllabi. Work in this regard has been undertaken and the manuals on radiographic testing and ultrasonic testing have already been issued in 1992 and 1999, respectively, in the Training Course Series. Compilation of this book is a continuation of that effort. These methods, in spite of their apparent simplicity, are the most widely used NDT methods to determine surface discontinuities, even in the most sophisticated of industries, including the nuclear and aerospace industries. The first draft of the book was put together by a group of consultants from Canada, Germany, India, Spain and Romania. It was reviewed by the National Centre for Non-destructive Testing (NCNDT) in Pakistan to bring it as close as possible to the syllabus requirements of IAEA-TECDOC-628. This has been done by putting in additional material wherever needed and then rearranging the whole in accordance with the format of Level 2 Surface Method Testing syllabi in IAEA-TECDOC-628

  20. Liquid penetrant and magnetic particle testing at level 2. Manual for the syllabi contained in IAEA-TECDOC-628, training guidelines in non-destructive testing techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-02-01

    specifications; be able to train and supervise the Level 1 staff under them and organize and report NDT results. The next logical step is to compile the textbooks and training manuals in accordance with these syllabi. Work in this regard has been undertaken and the manuals on radiographic testing and ultrasonic testing have already been issued in 1992 and 1999, respectively, in the Training Course Series. Compilation of this book is a continuation of that effort. These methods, in spite of their apparent simplicity, are the most widely used NDT methods to determine surface discontinuities, even in the most sophisticated of industries, including the nuclear and aerospace industries. The first draft of the book was put together by a group of consultants from Canada, Germany, India, Spain and Romania. It was reviewed by the National Centre for Non-destructive Testing (NCNDT) in Pakistan to bring it as close as possible to the syllabus requirements of IAEA-TECDOC-628. This has been done by putting in additional material wherever needed and then rearranging the whole in accordance with the format of Level 2 Surface Method Testing syllabi in IAEA-TECDOC-628.

  1. High-level neutron coincidence counter maintenance manual

    International Nuclear Information System (INIS)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included

  2. High-level neutron coincidence counter maintenance manual

    Energy Technology Data Exchange (ETDEWEB)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included.

  3. Development of manual procedures for care of pregnant patients in radiotherapy service; Desarrollo de manual de procedimentos para atencion de pacientes embarazadas en servicio de radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Scarabino, M.L., E-mail: maliscarabino@gmail.com [Hospital Italiano de Buenos Aires (HIBA), Buenos Aires (Argentina); Ruggeri, R.M.; Colombo, S.; Mairal, L.; Sardi, M.E., E-mail: ricardoruggeri@gmail.com [Mevaterapia Centro Medico, Buenos Aires (Argentina)

    2013-11-01

    The work involves the creation of a manual of procedures for the care of pregnant patients in a radiotherapy center in which each instance of treatment is included, from the obstetrician-oncology comprehensive assessment during admission to establishing controls newborn and its subsequent development in multidisciplinary team. For the preparation of the manual had to design an anthropomorphic phantom that resembles a pregnant woman, which was used to carry out internal and external dosimetry. In turn imparted calculations fetal doses using TPS, imaging tests with MRI, avoiding the use of the tomograph and adapted to the resonator involved were carried immobilizer. All experiences and progress made during the treated cases are introduced in the procedures manual, making it a dynamic tool for continuous improvement for the institution.

  4. Ultrasonic testing of materials at level 2. Manual for the syllabi contained in IAEA-TECDOC-628, training guidelines in non-destructive testing techniques

    International Nuclear Information System (INIS)

    1999-01-01

    The International Atomic Energy Agency (IAEA) has been active in the promotion of non-destructive testing (NDT) technology for many years. The prime reason for this interest has been the need for stringent quality control standards for the safe operation of nuclear installations. The IAEA has successfully executed a number of regional projects of which NDT was an important part. These were the Regional Co-operative Arrangements for the Promotion of Nuclear Science and Technology in Latin America (ARCAL), the Regional Co-operative Agreement for Asia and the Pacific (RCA), the African Regional Co-operative Agreement (AFRA) and lately the NDT Regional Project in West Asia. Through these projects a large number of persons have been trained in Member States and a state of self-sufficiency in this area of technology has been achieved in many of them. There has long been a realization of the need to have well established training guidelines and related books in order, firstly, to guide IAEA experts who were involved in this training programme and, secondly, to achieve some level of international uniformity and harmonization of training materials and consequent competence of personnel. The syllabi for training courses have been published in the form of two publications, IAEA-TECDOC-407 and IAEA-TECDOC-628. IAEA-TECDOC-628, as well as most of the international standards on the subject of training and certification of NDT personnel includes ISO 9712. The next logical step is to compile the textbooks and training manuals. Work in this regard has been undertaken and a manual on radiographic testing was issued in 1992 in the Training Course Series. This publication is a continuation of that effort. Earlier training notes on this subject existed in the form of IAEA-TECDOC-462, which was compiled in accordance with the syllabus of IAEA-TECDOC-407. These fulfilled the training needs of the member countries of RCA for quite some time. The present book is in fact an expanded and

  5. Proficiência e Assimetria Manual de Jovens com Trissomia 21, em duas Tarefas de Destreza Manual.

    Directory of Open Access Journals (Sweden)

    Luciana Krauss Rezende

    2016-07-01

    Resultados: No teste de DMF não se verificaram diferenças estatisticamente significativas (t(20=1.23, p=0.233 entre as mãos; porém, no teste de DMG a diferença entre as mãos alcançou significado estatístico (t(20=3.128, p=0,005, sendo a mão não preferida (145.22±53.42 seg. mais rápida do que a mão preferida (156.16±59.99 seg.. O Índice de Assimetria Manual para cada uma das tarefas foi calculado, porém, não revelou significado estatístico (t(20=-1.003, p=0.328. Conclusão: A melhor proficiência com a mão não preferida na tarefa de DMG pode estar relacionada com características peculiares para esta população, como as dificuldades na motricidade seletiva, o que empobreceria o desempenho para ambas as mãos, ou ainda com outros fatores a serem investigados. Os dados sugerem que tarefas de DMF e DMG desempenhadas por pessoas com T21 não são influenciadas pela preferência manual.

  6. Transuranic waste characterization sampling and analysis methods manual. Revision 1

    International Nuclear Information System (INIS)

    Suermann, J.F.

    1996-04-01

    This Methods Manual provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) for the Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) and the WIPP Waste Analysis Plan. This Methods Manual includes all of the testing, sampling, and analytical methodologies accepted by DOE for use in implementing the Program requirements specified in the QAPP and the WIPP Waste Analysis Plan. The procedures in this Methods Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site-specific procedures. With some analytical methods, such as Gas Chromatography/Mass Spectrometry, the Methods Manual procedures may be used directly. With other methods, such as nondestructive characterization, the Methods Manual provides guidance rather than a step-by-step procedure. Sites must meet all of the specified quality control requirements of the applicable procedure. Each DOE site must document the details of the procedures it will use and demonstrate the efficacy of such procedures to the Manager, National TRU Program Waste Characterization, during Waste Characterization and Certification audits

  7. Nevada National Security Site Radiological Control Manual

    International Nuclear Information System (INIS)

    2012-01-01

    This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 1 issued in February 2010. Brief Description of Revision: A complete revision to reflect a recent change in name for the NTS; changes in name for some tenant organizations; and to update references to current DOE policies, orders, and guidance documents. Article 237.2 was deleted. Appendix 3B was updated. Article 411.2 was modified. Article 422 was re-written to reflect the wording of DOE O 458.1. Article 431.6.d was modified. The glossary was updated. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada National Security Site (NNSS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. Current activities at NNSS include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of

  8. Nevada National Security Site Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers’ Council

    2012-03-26

    This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 1 issued in February 2010. Brief Description of Revision: A complete revision to reflect a recent change in name for the NTS; changes in name for some tenant organizations; and to update references to current DOE policies, orders, and guidance documents. Article 237.2 was deleted. Appendix 3B was updated. Article 411.2 was modified. Article 422 was re-written to reflect the wording of DOE O 458.1. Article 431.6.d was modified. The glossary was updated. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada National Security Site (NNSS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. Current activities at NNSS include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of

  9. Laboratory manual for salt-mixing test in 37- and 217-pin bundles

    International Nuclear Information System (INIS)

    Chan, Y.N.; Todreas, N.E.

    1980-08-01

    This laboratory manual deals with the procedure employed during salt tracer experiments used in evaluating the hydraulic characteristics of a rod bundle. A description of the standard equipment used is given together with the details of manufacture of probes used for detecting the salt concentration. Details of the bundle construction have been excluded as they are availble in the reference cited. An attempt has been made to point out potential trouble areas and procedures

  10. Bigfoot Field Manual, Version 2.1

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.L.; Burrows, S.; Gower, S.T.; Cohen, W.B.

    1999-09-01

    The BigFoot Project is funded by the Earth Science Enterprise to collect and organize data to be used in the National Aeronautics and Space Administration's Earth Observing System (EOS) Validation Program. The data collected by the BigFoot Project are unique in being ground-based observations coincident with satellite overpasses. In addition to collecting data, the BigFoot project will develop and test new algorithms for scaling point measurements to the same spatial scales as the EOS satellite products. This BigFoot Field Manual will be used to achieve completeness and consistency of data collected at four initial BigFoot sites and at future sites that may collect similar validation data. Therefore, validation datasets submitted to the Oak Ridge National Laboratory Distributed Active Archive Center that have been compiled in a manner consistent with the field manual will be especially valuable in the validation program.

  11. The effect of bedding system selected by manual muscle testing on sleep-related cardiovascular functions.

    Science.gov (United States)

    Kuo, Terry B J; Li, Jia-Yi; Lai, Chun-Ting; Huang, Yu-Chun; Hsu, Ya-Chuan; Yang, Cheryl C H

    2013-01-01

    Different types of mattresses affect sleep quality and waking muscle power. Whether manual muscle testing (MMT) predicts the cardiovascular effects of the bedding system was explored using ten healthy young men. For each participant, two bedding systems, one inducing the strongest limb muscle force (strong bedding system) and the other inducing the weakest limb force (weak bedding system), were identified using MMT. Each bedding system, in total five mattresses and eight pillows of different firmness, was used for two continuous weeks at the participant's home in a random and double-blind sequence. A sleep log, a questionnaire, and a polysomnography were used to differentiate the two bedding systems. Heart rate variability and arterial pressure variability analyses showed that the strong bedding system resulted in decreased cardiovascular sympathetic modulation, increased cardiac vagal activity, and increased baroreceptor reflex sensitivity during sleep as compared to the weak bedding system. Different bedding systems have distinct cardiovascular effects during sleep that can be predicted by MMT.

  12. Eddy Current Testing at Level 2: Manual for the Syllabi Contained in IAEA-TECDOC-628.Rev. 2 'Training Guidelines for Non Destructive Testing Techniques'

    International Nuclear Information System (INIS)

    2011-01-01

    level 2 is considered to be the most appropriate for persons who, beside other duties, are expected to independently undertake practical testing in the relevant method of NDT; develop NDT procedures adapted to various problems; prepare written instructions; make accept/reject decisions in accordance with relevant standards and specifications; organize and report NDT results and be able to train and supervise the level 1 staff under them. The next logical step has been to compile the text books and training manuals in accordance with these syllabi. Work in this regard has been undertaken and the manuals on liquid penetrant testing, magnetic particle testing, radiographic testing and ultrasonic testing have already been published in the Training Course Series. These play a vital role for training and certification of NDT personnel throughout the world. Compilation of this book is a continuation of that effort. The first draft of the book was developed as a home-based assignment by experts from Australia, the Republic of Korea and Pakistan. It was reviewed and finalized by an RCA consultants meeting of experts from Australia, the Republic of Korea and the United Kingdom, held in Vienna during 2009. This has been done by putting in additional material wherever needed and then rearranging the whole in accordance with the format of level 2 eddy current testing syllabi in IAEA-TECDOC- 628/Rev.2 (2008). The section on materials, manufacturing processes and defects and quality assurance, which is common to all the NDT methods, has been adapted from the previous publications in the Training Course Series

  13. GRACE manual

    International Nuclear Information System (INIS)

    Ishikawa, T.; Kawabata, S.; Shimizu, Y.; Kaneko, T.; Kato, K.; Tanaka, H.

    1993-02-01

    This manual is composed of three kinds of objects, theoretical background for calculating the cross section of elementary process, usage and technical details of the GRACE system. Throughout this manual we take the tree level process e + e - → W + W - γ as an example, including the e ± -scalar boson interactions. The real FORTRAN source code for this process is attached in the relevant sections as well as the results of calculation, which might be a great help for understanding the practical use of the system. (J.P.N.)

  14. Partners Plus: Families and Caregivers in Partnerships. A Family-Centered Guide to Respite Care. Trainer's Workshop Manual [and] Community Planning Manual [and] A Family Manual [and] Caregiver Manual.

    Science.gov (United States)

    Ownby, Lisa L.; Hooke, Amanda C.; Moore, Dee Wylie; Garland, Corinne W.; Frank, Adrienne

    Four manuals on implementing the Partners Respite Model, which provides respite care for children with disabilities or chronic illnesses, comprise this document. The Community Planning Manual offers a step-by-step guide to replication of the Partners Respite Model and is divided into sections on developing the Partners program, implementing the…

  15. Prospective study establishing a management plan for impacted third molar in patients undergoing hematopoietic stem cell transplantation.

    Science.gov (United States)

    Yamagata, Kenji; Onizawa, Kojiro; Yanagawa, Toru; Takeuchi, Yasutoshi; Hasegawa, Yuichi; Chiba, Shigeru; Bukawa, Hiroki

    2011-02-01

    Although dental treatment before hematopoietic stem cell transplantation (HSCT) is essential to prevent serious infections from oral sources, the best management plan for impacted third molar (ITM) is unclear. This study was planned to establish a management plan for ITM. Eighty-four candidates for HSCT therapy were consecutively enrolled in the prospective trial. The management plan, which was evidence based and prospectively decided, was to extract the symptomatic ITMs and to leave the asymptomatic ones untreated, regardless of their impacted position. Eighty-seven ITMs were observed in 35 patients. The ITMs were in the maxilla of 25 patients and the mandible of 28 patients. Dental extraction of 7 teeth was performed in 6 patients without complications. All of the patients received the scheduled HSCT therapy and none experienced odontogenic infection while myelosuppressed. This management plan for ITM appears to be appropriate for pre-HSCT patients. Moreover, the experienced dental provider is suggested as a necessary and valuable part of the HSCT team. Crown Copyright © 2011. Published by Mosby, Inc. All rights reserved.

  16. The ISIS Open GENIE user manual

    International Nuclear Information System (INIS)

    Akeroyd, F.A.; Ashworth, R.L.; Campbell, S.I.; Johnston, S.D.; Martin, J.M.; Moreton-Smith, C.M.; Sivia, D.S.

    2000-01-01

    This manual should enable you to become familiar with Open GENIE quickly and easily. It therefore complements the Open GENIE Reference Manual which should be used to understand the full meaning of Open GENIE commands. The reference manual is accessible on the ISIS web server at: http://www.isis.rl.ac.uk/GENIEReferenceManual/ and the user manual is planned to be accessible by January '98 at http://www.isis.rl.ac.ukIGENIEUserManual/. The Open GENIE User Manual is separated into two parts: Part A. The User Manual. An introduction to the use of Open GENIE. Part B. The Installation Guide. General information on how to install and run Open GENIE. Assuming that you are new to Open GENIE and have just downloaded a copy you will need to consult the Installation Guide to get Open GENIE installed on your machine. After this we recommend you experiment with some of the example files to get an idea of the capabilities of Open GENIE. For further information, comments, additions of routines that you feel should be included, please contact us at genie at isise.rl.ac.uk

  17. The operation and maintenance manual

    International Nuclear Information System (INIS)

    Stoll, A.; Krotil, H.; Klein, W.

    1976-01-01

    The operating manual is one of many technical documents which the nuclear power plant operator needs for ensuring safe operation. For the operating staff, however, there is only one document, namely the operating manual. The operating manual is an essential element in bringing man and machine in harmony. This is necessary for safe and, as far as possible, uninterrupted operation of the power plant. The operating manual is the only document containing binding instructions for plant operation. All the tasks of plant operation which are carried out by plant staff are described in the operating manual in a form which is as clear and comprehensible as possible. A considerable number of these tasks can only be carried out by man, namely: 1) tasks concerning operational organization, 2) all non-automated areas of plant operation. (orig./TK) [de

  18. Fire Protection Program Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2012-05-18

    This manual documents the Lawrence Livermore National Laboratory (LLNL) Fire Protection Program. Department of Energy (DOE) Orders 420.1B, Facility Safety, requires LLNL to have a comprehensive and effective fire protection program that protects LLNL personnel and property, the public and the environment. The manual provides LLNL and its facilities with general information and guidance for meeting DOE 420.1B requirements. The recommended readers for this manual are: fire protection officers, fire protection engineers, fire fighters, facility managers, directorage assurance managers, facility coordinators, and ES and H team members.

  19. NASCAP programmer's reference manual

    Science.gov (United States)

    Mandell, M. J.; Stannard, P. R.; Katz, I.

    1993-05-01

    The NASA Charging Analyzer Program (NASCAP) is a computer program designed to model the electrostatic charging of complicated three-dimensional objects, both in a test tank and at geosynchronous altitudes. This document is a programmer's reference manual and user's guide. It is designed as a reference to experienced users of the code, as well as an introduction to its use for beginners. All of the many capabilities of NASCAP are covered in detail, together with examples of their use. These include the definition of objects, plasma environments, potential calculations, particle emission and detection simulations, and charging analysis.

  20. Architectural study of the design and operation of advanced force feedback manual controllers

    Science.gov (United States)

    Tesar, Delbert; Kim, Whee-Kuk

    1990-01-01

    A teleoperator system consists of a manual controller, control hardware/software, and a remote manipulator. It was employed in either hazardous or unstructured, and/or remote environments. In teleoperation, the main-in-the-loop is the central concept that brings human intelligence to the teleoperator system. When teleoperation involves contact with an uncertain environment, providing the feeling of telepresence to the human operator is one of desired characteristics of the teleoperator system. Unfortunately, most available manual controllers in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size, high costs, or lack of smoothness and transparency, and elementary architectures. To investigate other alternatives, a force-reflecting, 3 degree of freedom (dof) spherical manual controller is designed, analyzed, and implemented as a test bed demonstration in this research effort. To achieve an improved level of design to meet criteria such as compactness, portability, and a somewhat enhanced force-reflecting capability, the demonstration manual controller employs high gear-ratio reducers. To reduce the effects of the inertia and friction on the system, various force control strategies are applied and their performance investigated. The spherical manual controller uses a parallel geometry to minimize inertial and gravitational effects on its primary task of transparent information transfer. As an alternative to the spherical 3-dof manual controller, a new conceptual (or parallel) spherical 3-dof module is introduced with a full kinematic analysis. Also, the resulting kinematic properties are compared to those of other typical spherical 3-dof systems. The conceptual design of a parallel 6-dof manual controller and its kinematic analysis is presented. This 6-dof manual controller is similar to the Stewart Platform with the actuators located on the base to minimize the dynamic effects. Finally, a combination of the new 3-dof and 6-dof

  1. ARS-Media for excel instruction manual

    Science.gov (United States)

    ARS-Media for Excel Instruction Manual is the instruction manual that explains how to use the Excel spreadsheet ARS-Media for Excel application. ARS-Media for Excel Instruction Manual is provided as a pdf file....

  2. Salinas : theory manual.

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Timothy Francis; Reese, Garth M.; Bhardwaj, Manoj Kumar

    2011-11-01

    Salinas provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas, we refer the reader to Salinas, User's Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature.

  3. Two thumbs and one index: A comparison of manual coordination in touch-typing and mobile-typing.

    Science.gov (United States)

    Cerni, Tania; Longcamp, Marieke; Job, Remo

    2016-06-01

    It has been extensively demonstrated that in touch-typing, manual alternation is performed faster than manual repetition (see i.e. Rumelhart & Norman, 1982), due to parallel activation of successive keystrokes. In this experiment, we tested whether the manual coordination patterns typical of touch-typing can be observed in mobile-typing. We recruited skilled touch-typists and divided them into two groups depending on their typing habits on the mobile device. The "one-hand" group typed with one index finger on the mobile, and therefore produced words exclusively through manual repetition. The "two-hands" group used two thumbs, and therefore produced words through a combination of mobile-typing repetitions and alternations. The two groups were tested in a typing to dictation task with both a standard keyboard and a mobile keyboard. Results showed that manual alternation and manual repetition patterns are similar in touch-typing and in mobile-typing. For the "two-hands" group, the mean interkeystroke intervals (IKIs) for touch-typing decreased as manual alterations in words increased in both touch- and mobile-typing. The "one-hand" group showed an opposite pattern in mobile-typing. Bigram frequency was correlated with IKIs per bigrams in both tasks and groups, but the correlation for the "one-hand" group in mobile-typing was different. Our results suggest that manual coordination processes are the same in touch-typing and in mobile-typing despite different effectors, provided that both hands are used to type. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. TJ-II Library Manual (Version 2)

    International Nuclear Information System (INIS)

    Tribaldos, V.; Milligen, B. Ph. van; Lopez-Fraguas, A.

    2001-01-01

    This is a manual of use of the TJ2 Numerical Library that has been developed for making numerical computations of different TJ-II configurations. This manual is a new version of the earlier manual CIEMAT report 806. (Author)

  5. Manual for guided home exercises for osteoarthritis of the knee

    Directory of Open Access Journals (Sweden)

    Nilza Aparecida de Almeida Carvalho

    2010-06-01

    Full Text Available INTRODUCTION: Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. METHODS: Thirty-eight adults with osteoarthritis of the knee (> 45 years old who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. RESULTS: The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. DISCUSSION: A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. CONCLUSIONS: Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial.

  6. GERTS GQ User's Manual.

    Science.gov (United States)

    Akiba, Y.; And Others

    This user's manual for the simulation program Graphical Evaluation and Review Technique (GERT) GQ contains sections on nodes, branches, program input description and format, and program output, as well as examples. Also included is a programmer's manual which contains information on scheduling, subroutine descriptions, COMMON Variables, and…

  7. Optimization of biological and instrumental detection of explosives and ignitable liquid residues including canines, SPME/ITMS and GC/MSn

    Science.gov (United States)

    Furton, Kenneth G.; Harper, Ross J.; Perr, Jeannette M.; Almirall, Jose R.

    2003-09-01

    A comprehensive study and comparison is underway using biological detectors and instrumental methods for the rapid detection of ignitable liquid residues (ILR) and high explosives. Headspace solid phase microextraction (SPME) has been demonstrated to be an effective sampling method helping to identify active odor signature chemicals used by detector dogs to locate forensic specimens as well as a rapid pre-concentration technique prior to instrumental detection. Common ignitable liquids and common military and industrial explosives have been studied including trinitrotoluene, tetryl, RDX, HMX, EGDN, PETN and nitroglycerine. This study focuses on identifying volatile odor signature chemicals present, which can be used to enhance the level and reliability of detection of ILR and explosives by canines and instrumental methods. While most instrumental methods currently in use focus on particles and on parent organic compounds, which are often involatile, characteristic volatile organics are generally also present and can be exploited to enhance detection particularly for well-concealed devices. Specific examples include the volatile odor chemicals 2-ethyl-1-hexanol and cyclohexanone, which are readily available in the headspace of the high explosive composition C-4; whereas, the active chemical cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) is not. The analysis and identification of these headspace 'fingerprint' organics is followed by double-blind dog trials of the individual components using certified teams in an attempt to isolate and understand the target compounds to which dogs are sensitive. Studies to compare commonly used training aids with the actual target explosive have also been undertaken to determine their suitability and effectiveness. The optimization of solid phase microextraction (SPME) combined with ion trap mobility spectrometry (ITMS) and gas chromatography/mass spectrometry/mass spectrometry (GC/MSn) is detailed including interface development

  8. Nuclear electronics laboratory manual

    International Nuclear Information System (INIS)

    1984-05-01

    The Nuclear Electronics Laboratory Manual is a joint product of several electronics experts who have been associated with IAEA activity in this field for many years. The manual does not include experiments of a basic nature, such as characteristics of different active electronics components. It starts by introducing small electronics blocks, employing one or more active components. The most demanding exercises instruct a student in the design and construction of complete circuits, as used in commercial nuclear instruments. It is expected that a student who completes all the experiments in the manual should be in a position to design nuclear electronics units and also to understand the functions of advanced commercial instruments which need to be repaired or maintained. The future tasks of nuclear electronics engineers will be increasingly oriented towards designing and building the interfaces between a nuclear experiment and a computer. The manual pays tribute to this development by introducing a number of experiments which illustrate the principles and the technology of interfacing

  9. Service-oriented architecture of adaptive, intelligent data acquisition and processing systems for long-pulse fusion experiments

    International Nuclear Information System (INIS)

    Gonzalez, J.; Ruiz, M.; Barrera, E.; Lopez, J.M.; Arcas, G. de; Vega, J.

    2010-01-01

    The data acquisition systems used in long-pulse fusion experiments need to implement data reduction and pattern recognition algorithms in real time. In order to accomplish these operations, it is essential to employ software tools that allow for hot swap capabilities throughout the temporal evolution of the experiments. This is very important because processing needs are not equal during different phases of the experiment. The intelligent test and measurement system (ITMS) developed by UPM and CIEMAT is an example of a technology for implementing scalable data acquisition and processing systems based on PXI and CompactPCI hardware. In the ITMS platform, a set of software tools allows the user to define the processing algorithms associated with the different experimental phases using state machines driven by software events. These state machines are specified using the State Chart XML (SCXML) language. The software tools are developed using JAVA, JINI, an SCXML engine and several LabVIEW applications. Within this schema, it is possible to execute data acquisition and processing applications in an adaptive way. The power of SCXML semantics and the ability to work with XML user-defined data types allow for very easy programming of the ITMS platform. With this approach, the ITMS platform is a suitable solution for implementing scalable data acquisition and processing systems based on a service-oriented model with the ability to easily implement remote participation applications.

  10. Services oriented architecture for adaptive and intelligent data acquisition and processing systems in long pulse fusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, J.; Ruiz, M.; Barrera, E.; Lopez, J.M.; De Arcas, G. [Universidad Politecnica de Madrid (Spain); Vega, J. [Association EuratomCIEMAT para Fusion, Madrid (Spain)

    2009-07-01

    Data acquisition systems used in long pulse fusion experiments require to implement data reduction and pattern recognition algorithms in real time. In order to accomplish these operations is essential to dispose software tools that allow hot swap capabilities throughout the temporal evolution of the experiments. This is very important because the processing needs are not equal in the different experiment's phases. The intelligent test and measurement system (ITMS) developed by UPM and CIEMAT is an example of technology for implementing scalable data acquisition and processing systems based in PXI and compact PCI hardware. In the ITMS platform a set of software tools allows the user to define the processing associated with the different experiment's phases using state machines driven by software events. These state machines are specified using State Chart XML (SCXML) language. The software tools are developed using: JAVA, JINI, a SCXML engine and several LabVIEW applications. With this schema it is possible to execute data acquisition and processing applications in an adaptive way. The powerful of SCXML semantics and the possibility of to work with XML user defined data types allow a very easy programming of ITMS platform. With this approach ITMS platform is a suitable solution for implementing scalable data acquisition and processing systems, based in a services oriented model, with ease possibility for implement remote participation applications. (authors)

  11. Service-oriented architecture of adaptive, intelligent data acquisition and processing systems for long-pulse fusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, J. [Grupo de Investigacion en Instrumentacion y Acustica Aplicada. Universidad Politecnica de Madrid, Crta. Valencia Km-7 Madrid 28031 (Spain); Ruiz, M., E-mail: mariano.ruiz@upm.e [Grupo de Investigacion en Instrumentacion y Acustica Aplicada. Universidad Politecnica de Madrid, Crta. Valencia Km-7 Madrid 28031 (Spain); Barrera, E.; Lopez, J.M.; Arcas, G. de [Grupo de Investigacion en Instrumentacion y Acustica Aplicada. Universidad Politecnica de Madrid, Crta. Valencia Km-7 Madrid 28031 (Spain); Vega, J. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)

    2010-07-15

    The data acquisition systems used in long-pulse fusion experiments need to implement data reduction and pattern recognition algorithms in real time. In order to accomplish these operations, it is essential to employ software tools that allow for hot swap capabilities throughout the temporal evolution of the experiments. This is very important because processing needs are not equal during different phases of the experiment. The intelligent test and measurement system (ITMS) developed by UPM and CIEMAT is an example of a technology for implementing scalable data acquisition and processing systems based on PXI and CompactPCI hardware. In the ITMS platform, a set of software tools allows the user to define the processing algorithms associated with the different experimental phases using state machines driven by software events. These state machines are specified using the State Chart XML (SCXML) language. The software tools are developed using JAVA, JINI, an SCXML engine and several LabVIEW applications. Within this schema, it is possible to execute data acquisition and processing applications in an adaptive way. The power of SCXML semantics and the ability to work with XML user-defined data types allow for very easy programming of the ITMS platform. With this approach, the ITMS platform is a suitable solution for implementing scalable data acquisition and processing systems based on a service-oriented model with the ability to easily implement remote participation applications.

  12. Detecting accuracy of flaws by manual and automatic ultrasonic inspections

    International Nuclear Information System (INIS)

    Iida, K.

    1988-01-01

    As the final stage work in the nine year project on proving tests of the ultrasonic inspection technique applied to the ISI of LWR plants, automatic ultrasonic inspection tests were carried out on EDM notches, surface fatigue cracks, weld defects and stress corrosion cracks, which were deliberately introduced in full size structural components simulating a 1,100 MWe BWR. Investigated items are the performance of a newly assembled automatic inspection apparatus, detection limit of flaws, detection resolution of adjacent collinear or parallel EDM notches, detection reproducibility and detection accuracy. The manual ultrasonic inspection of the same flaws as inspected by the automatic ultrasonic inspection was also carried out in order to have comparative data. This paper reports how it was confirmed that the automatic ultrasonic inspection is much superior to the manual inspection in the flaw detection rate and in the detection reproducibility

  13. 14 CFR 121.141 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 121.141 Section 121... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Manual Requirements § 121.141 Airplane flight manual. (a) Each certificate holder shall keep a current approved airplane flight manual for each type of...

  14. The utility of six over-the-counter (home) pregnancy tests.

    Science.gov (United States)

    Cole, Laurence A

    2011-08-01

    The home pregnancy market is rapidly evolving. It has moved from detection of pregnancy on the day of missed menstrual bleeding, to detection claims 4 days prior. It is moving from all manual tests to digital tests, with a monitor reading the bands and informing women they are pregnant. A thorough study is needed to investigate the validity of claims and evolving usefulness of devices. Studies were proposed to examine the sensitivity and specificity of home tests and their abilities to detect pregnancy. Methods examined the abilities of tests to detect human chorionic gonadotropin (hCG), hyperglycosylated hCG, free β-subunit, a mixture of these antigens in 40 individual early pregnancy urines. Using a mixture of hCG, hyperglycosylated hCG and free β-subunit typical for early pregnancy, the sensitivity of the First Response manual and digital tests was 5.5 mIU/mL, while the sensitivities of the EPT and ClearBlue brand manual and digital tests was 22 mIU/mL. On further evaluation, the First Response manual and digital tests both detected 97% of 120 pregnancies on the day of missed menstrual bleeding. The EPT manual and digital devices detected 54% and 67% of pregnancies, respectively, and the ClearBlue manual and digital devices detected 64% and 54% of pregnancies, respectively. First Response manual and digital claim >99% detection on the day of missed menses. The results here suggest similar sensitivity for these two tests. The EPT and ClearBlue manual and digital test make similar >99% claims, the data presented here disputes their elevated claim.

  15. The National Energy Audit (NEAT) Engineering Manual (Version 6)

    Energy Technology Data Exchange (ETDEWEB)

    Gettings, M.B.

    2001-04-20

    Government-funded weatherization assistance programs resulted from increased oil prices caused by the 1973 oil embargo. These programs were instituted to reduce US consumption of oil and help low-income families afford the increasing cost of heating their homes. In the summer of 1988, Oak Ridge National Laboratory (ORNL) began providing technical support to the Department of Energy (DOE) Weatherization Assistance Program (WAP). A preliminary study found no suitable means of cost-effectively selecting energy efficiency improvements (measures) for single-family homes that incorporated all the factors seen as beneficial in improving cost-effectiveness and usability. In mid-1989, ORNL was authorized to begin development of a computer-based measure selection technique. In November of 1992 a draft version of the program was made available to all WAP state directors for testing. The first production release, Version 4.3, was made available in october of 1993. The Department of Energy's Weatherization Assistance Program has continued funding improvements to the program increasing its user-friendliness and applicability. initial publication of this engineering manual coincides with availability of Version 6.1, November 1997, though algorithms described generally apply to all prior versions. Periodic updates of specific sections in the manual will permit maintaining a relevant document. This Engineering Manual delineates the assumptions used by NEAT in arriving at the measure recommendations based on the user's input of the building characteristics. Details of the actual data entry are available in the NEAT User's Manual (ORNL/Sub/91-SK078/1) and will not be discussed in this manual.

  16. Mass Balance. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    Science.gov (United States)

    Carnegie, John W.

    This module describes the process used to determine solids mass and location throughout a waste water treatment plant, explains how these values are used to determine the solids mass balance around single treatment units and the entire system, and presents calculations of solids in pounds and sludge units. The instructor's manual contains a…

  17. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods:

  18. Oil Spill Response Manual

    NARCIS (Netherlands)

    Marieke Zeinstra; Sandra Heins; Wierd Koops

    2014-01-01

    A two year programme has been carried out by the NHL University of Applied Sciences together with private companies in the field of oil and chemical spill response to finalize these manuals on oil and chemical spill response. These manuals give a good overview of all aspects of oil and chemical

  19. 46 CFR 160.176-21 - User manuals.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false User manuals. 160.176-21 Section 160.176-21 Shipping...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Inflatable Lifejackets § 160.176-21 User manuals. (a) The manufacturer must develop a user's manual for each model of inflatable lifejacket. The content of the manual...

  20. US Department of Energy radiological control manual

    International Nuclear Information System (INIS)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements

  1. Comparative microbial sampling from eutrophic caves in Slovenia and Slovakia using RIDA®COUNT test kits

    Czech Academy of Sciences Publication Activity Database

    Mulec, J.; Krištůfek, Václav; Chroňáková, Alica

    2012-01-01

    Roč. 41, č. 1 (2012), s. 1-8 ISSN 0392-6672 R&D Projects: GA MŠk LC06066 Grant - others:SSJ(SK) ITMS 24150120041-OPZP-P05-09-01 Institutional research plan: CEZ:AV0Z60660521 Keywords : caves * monitoring * air * water Subject RIV: EH - Ecology, Behaviour Impact factor: 1.344, year: 2012

  2. Intrathecal morphine is superior to intravenous PCA in patients undergoing minimally invasive cardiac surgery

    Directory of Open Access Journals (Sweden)

    Chirojit Mukherjee

    2012-01-01

    Full Text Available Aim of our study was to evaluate the beneficial effect of low dose intrathecal morphine on postoperative analgesia, over the use of intravenous patient controlled anesthesia (PCA, in patients undergoing fast track anesthesia during minimally invasive cardiac surgical procedures. A randomized controlled trial was undertaken after approval from local ethical committee. Written informed consent was obtained from 61 patients receiving mitral or tricuspid or both surgical valve repair in minimal invasive technique. Patients were assigned randomly to 2 groups. Group 1 received general anesthesia and intravenous patient controlled analgesia (PCA pump with Piritramide (GA group. Group 2 received a single shot of intrathecal morphine (1.5 μg/kg body weight prior to the administration of general anesthesia (ITM group. Site of puncture was confined to lumbar (L1-2 or L2-3 intrathecal space. The amount of intravenous piritramide used in post anesthesia care unit (PACU and the first postoperative day was defined as primary end point. Secondary end points included: time for tracheal extubation, pain and sedation scores in PACU upto third postoperative day. For statistical analysis Mann-Whitney-U Test and Fishers exact test (SPSS were used. We found that the demand for intravenous opioids in PACU was significantly reduced in ITM group (P <0.001. Pain scores were significantly decreased in ITM group until second postoperative day (P <0.01. There was no time delay for tracheal extubation in ITM group, and sedation scores did not differ in either group. We conclude that low dose single shot intrathecal morphine provides adequate postoperative analgesia, reduces the intravenous opioid consumption during the early postoperative period and does not defer early extubation.

  3. Development of manual procedures for care of pregnant patients in radiotherapy service

    International Nuclear Information System (INIS)

    Scarabino, M.L.; Ruggeri, R.M.; Colombo, S.; Mairal, L.; Sardi, M.E.

    2013-01-01

    The work involves the creation of a manual of procedures for the care of pregnant patients in a radiotherapy center in which each instance of treatment is included, from the obstetrician-oncology comprehensive assessment during admission to establishing controls newborn and its subsequent development in multidisciplinary team. For the preparation of the manual had to design an anthropomorphic phantom that resembles a pregnant woman, which was used to carry out internal and external dosimetry. In turn imparted calculations fetal doses using TPS, imaging tests with MRI, avoiding the use of the tomograph and adapted to the resonator involved were carried immobilizer. All experiences and progress made during the treated cases are introduced in the procedures manual, making it a dynamic tool for continuous improvement for the institution

  4. Technical Manual. The ACT®

    Science.gov (United States)

    ACT, Inc., 2014

    2014-01-01

    This manual contains technical information about the ACT® college readiness assessment. The principal purpose of this manual is to document the technical characteristics of the ACT in light of its intended purposes. ACT regularly conducts research as part of the ongoing formative evaluation of its programs. The research is intended to ensure that…

  5. Environment, safety, and health manual, closeout report

    International Nuclear Information System (INIS)

    1975-12-01

    A coordination draft of the Environment, Safety, and Health (ES and H) manual was submitted on 2 September 1975. Comments provided by Operational Safety personnel were being incorporated by a task team when the effort was terminated on 31 October 1975. This report documents the development history of the manual and provides a status of the manual up to the time the efforts were discontinued. Also discussed are issues which effect completion of the manual. Additionally a plan for completion of the manual is suggested

  6. Marketing Research. Instructor's Manual.

    Science.gov (United States)

    Small Business Administration, Washington, DC.

    Prepared for the Administrative Management Course Program, this instructor's manual was developed to serve small-business management needs. The sections of the manual are as follows: (1) Lesson Plan--an outline of material covered, which may be used as a teaching guide, presented in two columns: the presentation, and a step-by-step indication of…

  7. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  8. 25 CFR 175.5 - Operations manual.

    Science.gov (United States)

    2010-04-01

    ... Provisions § 175.5 Operations manual. (a) The Area Director shall establish an operations manual for the... Director shall amend the operations manual as needed. (b) The public shall be notified by the Area Director... shall be published in local newspaper(s) of general circulation, posted at the utility office(s), and...

  9. AFM-CMM integrated instrument user manual

    DEFF Research Database (Denmark)

    Marinello, Francesco; Bariani, Paolo

    This manual gives general important guidelines for a proper use of the integrated AFM-CMM instrument. More information can be collected reading: • N. Kofod Ph.D thesis [1]; • P. Bariani Ph.D thesis [2]; • Dualscope DME 95-200 operation manuals [3]; • SPIP help [4] • Stitching software user manual...

  10. Evaluation of idiopathic transverse myelitis revealing specific myelopathy diagnoses.

    Science.gov (United States)

    Zalewski, Nicholas L; Flanagan, Eoin P; Keegan, B Mark

    2018-01-09

    To evaluate specific myelopathy diagnoses made in patients with suspected idiopathic transverse myelitis (ITM). A total of 226 patients 18 years and older were referred to Mayo Clinic Neurology for suspected ITM from December 1, 2010, to December 31, 2015. Electronic medical records were reviewed for detailed clinical presentation and course, laboratory and electrophysiologic investigations, and neuroimaging to determine the etiology. Current diagnostic criteria for ITM and alternative myelopathy diagnoses were applied. All cases where any discrepancy was suspected from the final reported clinical diagnosis were reviewed by each author and a consensus final diagnosis was made. The diagnostic criteria for ITM were met in 41 of 226 patients (18.1%). In 158 patients (69.9%), an alternative specific myelopathy diagnosis was made: multiple sclerosis or clinically isolated syndrome, 75; vascular myelopathy, 41; neurosarcoidosis, 12; neuromyelitis optica spectrum disorder, 12; myelin oligodendrocyte glycoprotein myelopathy, 5; neoplastic, 4; compressive, 3; nutritional, 3; infectious, 2; and other, 2. A myelopathy was not confirmed in 27 patients. Time from symptom onset to final clinical diagnosis in patients without ITM was a median of 9 months (range 0-288). Fifty-five patients (24%) required treatment changes according to their final clinical diagnosis. The majority of patients with suspected ITM have an alternative specific myelopathy diagnosis. A presumptive diagnosis of ITM can lead to premature diagnostic conclusions affecting patient treatment. Copyright © 2017 American Academy of Neurology.

  11. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-07-25

    The purpose of the Regulations and Procedures Manual (RPM) is to provide LBNL personnel with a reference to University and Lawrence Berkeley National Laboratory (LBNL or Laboratory) policies and regulations by outlining normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory organizations. Much of the information in this manual has been condensed from detail provided in LBNL procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. RPM sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the LBNL organization responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which organization is responsible for a policy, please contact Requirements Manager Lydia Young or the RPM Editor.

  12. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-09-30

    The purpose of the Regulations and Procedures Manual (RPM) is to provide Laboratory personnel with a reference to University and Lawrence Berkeley National Laboratory policies and regulations by outlining the normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory departments. Much of the information in this manual has been condensed from detail provided in Laboratory procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. The sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the department responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which department should be called, please contact the Associate Laboratory Director of Operations.

  13. Manual for subject analysis

    International Nuclear Information System (INIS)

    2002-01-01

    This document is one in a series of publications known as the ETDE/INIS Joint Reference Series and also constitutes a part of the ETDE Procedures Manual. It presents the rules, guidelines and procedures to be adopted by centers submitting input to the International Nuclear Information System (INIS) or the Energy Technology Data Exchange (ETDE). It is a manual for the subject analysis part of input preparation, meaning the selection, subject classification, abstracting and subject indexing of relevant publications, and is to be used in conjunction with the Thesauruses, Subject Categories documents and the documents providing guidelines for the preparation of abstracts. The concept and structure of the new manual are intended to describe in a logical and efficient sequence all the steps comprising the subject analysis of documents to be reported to INIS or ETDE. The manual includes new chapters on preparatory analysis, subject classification, abstracting and subject indexing, as well as rules, guidelines, procedures, examples and a special chapter on guidelines and examples for subject analysis in particular subject fields. (g.t.; a.n.)

  14. Software Users Manual (SUM): Extended Testability Analysis (ETA) Tool

    Science.gov (United States)

    Maul, William A.; Fulton, Christopher E.

    2011-01-01

    This software user manual describes the implementation and use the Extended Testability Analysis (ETA) Tool. The ETA Tool is a software program that augments the analysis and reporting capabilities of a commercial-off-the-shelf (COTS) testability analysis software package called the Testability Engineering And Maintenance System (TEAMS) Designer. An initial diagnostic assessment is performed by the TEAMS Designer software using a qualitative, directed-graph model of the system being analyzed. The ETA Tool utilizes system design information captured within the diagnostic model and testability analysis output from the TEAMS Designer software to create a series of six reports for various system engineering needs. The ETA Tool allows the user to perform additional studies on the testability analysis results by determining the detection sensitivity to the loss of certain sensors or tests. The ETA Tool was developed to support design and development of the NASA Ares I Crew Launch Vehicle. The diagnostic analysis provided by the ETA Tool was proven to be valuable system engineering output that provided consistency in the verification of system engineering requirements. This software user manual provides a description of each output report generated by the ETA Tool. The manual also describes the example diagnostic model and supporting documentation - also provided with the ETA Tool software release package - that were used to generate the reports presented in the manual

  15. Reconceptualising manual therapy skills in contemporary practice.

    Science.gov (United States)

    Rabey, Martin; Hall, Toby; Hebron, Clair; Palsson, Thorvaldur Skuli; Christensen, Steffan Wittrup; Moloney, Niamh

    2017-06-01

    With conflicting evidence regarding the effectiveness of manual therapy calls have arisen within some quarters of the physiotherapy profession challenging the continued use of manual skills for assessment and treatment. A reconceptualisation of the importance of manual examination findings is put forward, based upon a contemporary understanding of pain science, rather than considering these skills only in terms of how they should "guide" manual therapy interventions. The place for manual examination findings within complex, multidimensional presentations is considered using vignettes describing the presentations of five people with low back pain. As part of multidimensional, individualised management, the balance of evidence relating to the effectiveness, mechanisms of action and rationale for manual skills is discussed. It is concluded that if manual examination and therapeutic skills are used in a manner consistent with a contemporary understanding of pain science, multidimensional patient profiles and a person-centred approach, their selective and judicious use still has an important role. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Cost-effectiveness of clust X-ray follow-up of patients treated for seminoma of the testis

    Energy Technology Data Exchange (ETDEWEB)

    Ciatto, S; Cionini, L; Pacini, P

    1986-01-01

    The authors report on a consecutive series of 253 cases of seminoma of the testis followed with periodic chest X-ray examinations from a minimum of three to a maximum of 27 years. The detection rate of asymptomatic intrathoracic metastases (ITM) was considered together with the costs of the follow-up procedure. Chest X-ray follow-up is not advisable beyound one year from primary treatment, since most (14 of 18) ITM occur in the first year, the detection rate of ITM beyond this date is too low (0.11% patients/year), and the related costs are too high (over $ 130,000 per ITM detected). Chest X-ray follow-up is questionable even in the first year primary treatment for Stage I cases bacause of the low detection rate (1.38 % patients/year) and the high costs (over $ 14,000 per ITM detected), whwreas it appears to be opportune in Stage IIA and IIB.

  17. A Discussion of Assessment Needs in Manual Communication for Pre-College Students.

    Science.gov (United States)

    Cokely, Dennis R.

    The paper reviews issues in evaluating the manual communications skills of pre-college hearing impaired students, including testing of visual discrimination and visual memory, simultaneous communication, and attention span. (CL)

  18. Community cooperatives and insecticide-treated materials for malaria control: a new experience in Latin America.

    Science.gov (United States)

    Kroeger, Axel; Aviñna, Ana; Ordoñnez-Gonzalez, José; Escandon, Celia

    2002-11-15

    Insecticide-treated materials (ITMs) are effective in substantially reducing the burden of malaria and other vector-borne diseases; but how can high coverage rates of ITMs be achieved and maintained? In south Mexico and on the Pacific and Atlantic coasts of Colombia 14 community-based cooperatives offering three different kinds of ITM services (sale of impregnation services; sale of impregnated nets; production of nets and sale of impregnated nets) were formed and supervised by a national health service (IMSS-SOLIDARIDAD, Mexico) and by an academic institution (the Colombian Institute of Tropical Medicine) along with local district health services. The objectives of this research were to analyse the processes and results of this approach and to identify the favourable and limiting factors. The methods used for data collection and analysis were group discussions, individual and semi-structured interviews with users and non-users of ITMs, individual in-depth interviews with cooperative members and supervisors, checks of sales book and observation of impregnation services. Coverage with unimpregnated nets was above 50% in all study areas. The fastest increase of ITM coverage was achieved through the exclusive sale of impregnation services. Low-cost social marketing techniques were used to increase demand. The large-scale production of nets in two cooperatives was only possible with the aid of an international NGO which ordered impregnated bednets for their target group. A number of favourable and limiting factors relating to the success of ITM cooperatives were identified. Of particular importance for the more successful Mexican cooperatives were: a) support by health services, b) smaller size, c) lesser desire for quick returns and d) lower ITM unit costs. ITM community cooperatives supported and supervised by the health services have good potential in the Latin American context for achieving and maintaining high impregnation rates.

  19. Community cooperatives and insecticide-treated materials for malaria control: a new experience in Latin America

    Directory of Open Access Journals (Sweden)

    Ordoñnez-Gonzalez José

    2002-11-01

    Full Text Available Abstract Background and objectives Insecticide-treated materials (ITMs are effective in substantially reducing the burden of malaria and other vector-borne diseases; but how can high coverage rates of ITMs be achieved and maintained? In south Mexico and on the Pacific and Atlantic coasts of Colombia 14 community-based cooperatives offering three different kinds of ITM services (sale of impregnation services; sale of impregnated nets; production of nets and sale of impregnated nets were formed and supervised by a national health service (IMSS-SOLIDARIDAD, Mexico and by an academic institution (the Colombian Institute of Tropical Medicine along with local district health services. The objectives of this research were to analyse the processes and results of this approach and to identify the favourable and limiting factors. Methods The methods used for data collection and analysis were group discussions, individual and semi-structured interviews with users and non-users of ITMs, individual in-depth interviews with cooperative members and supervisors, checks of sales book and observation of impregnation services. Results Coverage with unimpregnated nets was above 50% in all study areas. The fastest increase of ITM coverage was achieved through the exclusive sale of impregnation services. Low-cost social marketing techniques were used to increase demand. The large-scale production of nets in two cooperatives was only possible with the aid of an international NGO which ordered impregnated bednets for their target group. A number of favourable and limiting factors relating to the success of ITM cooperatives were identified. Of particular importance for the more successful Mexican cooperatives were: a support by health services, b smaller size, c lesser desire for quick returns and d lower ITM unit costs. Conclusions ITM community cooperatives supported and supervised by the health services have good potential in the Latin American context for achieving

  20. An automatic algorithm for blink-artifact suppression based on iterative template matching: application to single channel recording of cortical auditory evoked potentials

    Science.gov (United States)

    Valderrama, Joaquin T.; de la Torre, Angel; Van Dun, Bram

    2018-02-01

    Objective. Artifact reduction in electroencephalogram (EEG) signals is usually necessary to carry out data analysis appropriately. Despite the large amount of denoising techniques available with a multichannel setup, there is a lack of efficient algorithms that remove (not only detect) blink-artifacts from a single channel EEG, which is of interest in many clinical and research applications. This paper describes and evaluates the iterative template matching and suppression (ITMS), a new method proposed for detecting and suppressing the artifact associated with the blink activity from a single channel EEG. Approach. The approach of ITMS consists of (a) an iterative process in which blink-events are detected and the blink-artifact waveform of the analyzed subject is estimated, (b) generation of a signal modeling the blink-artifact, and (c) suppression of this signal from the raw EEG. The performance of ITMS is compared with the multi-window summation of derivatives within a window (MSDW) technique using both synthesized and real EEG data. Main results. Results suggest that ITMS presents an adequate performance in detecting and suppressing blink-artifacts from a single channel EEG. When applied to the analysis of cortical auditory evoked potentials (CAEPs), ITMS provides a significant quality improvement in the resulting responses, i.e. in a cohort of 30 adults, the mean correlation coefficient improved from 0.37 to 0.65 when the blink-artifacts were detected and suppressed by ITMS. Significance. ITMS is an efficient solution to the problem of denoising blink-artifacts in single-channel EEG applications, both in clinical and research fields. The proposed ITMS algorithm is stable; automatic, since it does not require human intervention; low-invasive, because the EEG segments not contaminated by blink-artifacts remain unaltered; and easy to implement, as can be observed in the Matlab script implemeting the algorithm provided as supporting material.

  1. TRUBA User Manual

    International Nuclear Information System (INIS)

    Tereshchenko, M. A.; Castejon, F.; Cappa, A.

    2008-01-01

    The TRUBA (pipeline in Russian) code is a computational tool for studying the propagation of Gaussian-shaped microwave beams in a prescribed equilibrium plasma. This manual covers the basic material handed to use the implementation of TRUBA (version 3,4) interfaced with the numerical library of the TJ-II stellarator. The manual provides a concise theoretical background of the problem, specifications for setting up the input files and interpreting the output of the code, and some information useful in modifying TRUBA. (Author) 13 refs

  2. TRUBA User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Tereshchenko, M. A.; Castejon, F.; Cappa, A.

    2008-04-25

    The TRUBA (pipeline in Russian) code is a computational tool for studying the propagation of Gaussian-shaped microwave beams in a prescribed equilibrium plasma. This manual covers the basic material handed to use the implementation of TRUBA (version 3,4) interfaced with the numerical library of the TJ-II stellarator. The manual provides a concise theoretical background of the problem, specifications for setting up the input files and interpreting the output of the code, and some information useful in modifying TRUBA. (Author) 13 refs.

  3. Developing a Pupil Transportation Manual.

    Science.gov (United States)

    Douglas, Dave

    1987-01-01

    District-level pupil transportation manuals that contain clear, concise information about objectives, policies, and regulations are a must. These manuals should also specify procedures concerning evaluation processes, personnel recruitment and selection, and the driver training program. (MLH)

  4. Transferring manual ultrasonic inspection procedures - results of a pilot study

    International Nuclear Information System (INIS)

    Anderson, M.; Taylor, T.; Kadenko, I.

    2002-01-01

    Results of a manual ultrasonic pilot study for NDE specialists at RBMK nuclear reactor sites are presented. Probabilities of detection and false calls, using two different grading criteria, are estimated. Analyses of performance parameters lead to conclusions regarding attributes for improved test discrimination capabilities. (orig.)

  5. Missouri Highway Safety Manual Recalibration

    Science.gov (United States)

    2018-05-01

    The Highway Safety Manual (HSM) is a national manual for analyzing the highway safety of various facilities, including rural roads, urban arterials, freeways, and intersections. The HSM was first published in 2010, and a 2014 supplement addressed fre...

  6. Effluent-Monitoring Procedures: Basic Laboratory Skills. Student Reference Manual.

    Science.gov (United States)

    Engel, William T.; And Others

    This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. This Student Reference Manual provides a review of basic mathematics as it applies to the chemical laboratory. The…

  7. Nutritional Screening of Children: A Manual for Screening & Followup.

    Science.gov (United States)

    Bureau of Community Health Services (DHHS/PHS), Rockville, MD.

    This manual shows health providers how to perform precisely and expertly each step of several procedures used in screening children for nutritional problems. It is intended for all health providers who are involved in weighing and measuring children, recording and plotting measurements on growth charts, taking blood samples to test for iron…

  8. Manual Development and Pilot Testing of a Mindfulness- and Acceptance-Based Intervention for Increasing Cardiorespiratory Fitness in Sedentary Adults

    OpenAIRE

    Martin, Emily Cecile

    2012-01-01

    The aim of this research project was to conduct a manual development study and an open clinical trial in order to demonstrate the feasibility and efficacy of a mindfulness and acceptance based intervention for increasing cardiorespiratory fitness (CRF) in sedentary adults through adherence to a fitness walking program. Development of the treatment manual followed a 3-phase process (literature review and initial draft preparation, expert review, draft revision) based on expert systems analysis...

  9. US Department of Energy Radiological Control Manual

    International Nuclear Information System (INIS)

    1992-06-01

    This manual establishes practices for the conduct of radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. (VC)

  10. Potential Applications of Manual Games,

    Science.gov (United States)

    1984-02-01

    34 just because some electronic equipment is used to keep track of logistics, combat results, and force status. Even a highly computerized game like...D-A152 541 POTENTIAL APPLICATIONS OF MANUAL GAMES (U) RAND CORP ii SANTA MONICA CA T A BROW~N FEB 84 RAND/P-6957 UNCLASI7FIED F/G 12/2 N El..I 111 1...128 112.5 111 m; * _ 1.8 I1111 ’I’ll MICROCOPY RESOLUTION TEST CHART NATI NAl fii~ t1 RI 1A L4k, I POTENTIAL APPLICATIONS OF MANUJAL GAMES Lfl N Lfl

  11. Paresthesia: A Review of Its Definition, Etiology and Treatments in View of the Traditional Medicine.

    Science.gov (United States)

    Emami, Seyed Ahmad; Sahebkar, Amirhossein; Javadi, Behjat

    2016-01-01

    To search major Islamic Traditional Medicine (ITM) textbooks for definition, etiology and medicinal plants used to manage 'khadar' or 'paresthesia', a common sensory symptom of multiple sclerosis (MS) and peripheral neuropathies. In addition, the conformity of the efficacy of ITM-suggested plants with the findings from modern pharmacological research on MS will be discussed. Data on the medicinal plants used to treat 'khadar' were obtained from major ITM texts. A detailed search in PubMed, ScienceDirect, Scopus and Google Scholar databases was performed to confirm the effects of ITM-mentioned medicinal plants on MS in view of identified pharmacological actions. Moringa oleifera Lam., Aloe vera (L.) Burm.f., Euphorbia species, Citrullus colocynthis (L.) Schrad., and Costus speciosus (Koen ex. Retz) Sm. are among the most effective ITM plants for the management of 'khadar'. Recent experimental evidence confirms the effectiveness of the mentioned plants in ameliorating MS symptoms. Moreover, according to ITM, prolonged exposure to cold and consuming foodstuff with cold temperament might be involved in the etiopathogenesis of MS. The use of traditional knowledge can help finding neglected risk factors as well as effective and safe therapeutic approaches, phytomedicines and dietary habits for the management of paresthesia and related disorders such as MS.

  12. Difference between manual and digital measurements of dental arches of orthodontic patients.

    Science.gov (United States)

    Jiménez-Gayosso, Sandra Isabel; Lara-Carrillo, Edith; López-González, Saraí; Medina-Solís, Carlo Eduardo; Scougall-Vilchis, Rogelio José; Hernández-Martínez, César Tadeo; Colomé-Ruiz, Gabriel Eduardo; Escoffié-Ramirez, Mauricio

    2018-06-01

    The objective of this study was to compare the differences between the measurements performed manually to those obtained using a digital model scanner of patients with orthodontic treatment.A cross-sectional study was performed in a sample of 30 study models from patients with permanent dentition who attended a university clinic between January 2010 and December 2015. For the digital measurement, a Maestro 3D Ortho Studio scanner (Italy) was used and Mitutoyo electronic Vernier calipers (Kawasaki, Japan) were used for manual measurement. The outcome variables were the measurements for maxillary intercanine width, mandibular intercanine width, maxillary intermolar width, mandibular intermolar width, overjet, overbite, maxillary arch perimeter, mandibular arch perimeter, and palate height. The independent variables, besides age and sex, were a series of arc characteristics. The Student t test, paired Student t test, and Pearson correlation in SPSS version 19 were used for the analysis.Of the models, 60% were from women. Two of nine measurements for pre-treatment and 6 of 9 measurements for post-treatment showed a difference. The variables that were different between the manual and digital measurements in the pre-treatment were maxillary intermolar width and palate height (P manually and digitally showed certain similarities for both vertical and transverse measurements. There are many advantages offered to the orthodontist, such as easy storage; savings in time and space; facilitating the reproducibility of information; and conferring the security of not deteriorating over time. Its main disadvantage is the cost.

  13. A motor learning approach to training wheelchair propulsion biomechanics for new manual wheelchair users: A pilot study.

    Science.gov (United States)

    Morgan, Kerri A; Tucker, Susan M; Klaesner, Joseph W; Engsberg, Jack R

    2017-05-01

    Developing an evidence-based approach to teaching wheelchair skills and proper propulsion for everyday wheelchair users with a spinal cord injury (SCI) is important to their rehabilitation. The purpose of this project was to pilot test manual wheelchair training based on motor learning and repetition-based approaches for new manual wheelchair users with an SCI. A repeated measures within-subject design was used with participants acting as their own controls. Six persons with an SCI requiring the use of a manual wheelchair participated in wheelchair training. The training included nine 90-minute sessions. The primary focus was on wheelchair propulsion biomechanics with a secondary focus on wheelchair skills. During Pretest 1, Pretest 2, and Posttest, wheelchair propulsion biomechanics were measured using the Wheelchair Propulsion Test and a Video Motion Capture system. During Pretest 2 and Posttest, propulsion forces using the WheelMill System and wheelchair skills using the Wheelchair Skills Test were measured. Significant changes in area of the push loop, hand-to-axle relationship, and slope of push forces were found. Changes in propulsion patterns were identified post-training. No significant differences were found in peak and average push forces and wheelchair skills pre- and post-training. This project identified trends in change related to a repetition-based motor learning approach for propelling a manual wheelchair. The changes found were related to the propulsion patterns used by participants. Despite some challenges associated with implementing interventions for new manual wheelchair users, such as recruitment, the results of this study show that repetition-based training can improve biomechanics and propulsion patterns for new manual wheelchair users.

  14. Manual of selected physico-chemical analytical methods. IV

    International Nuclear Information System (INIS)

    Beran, M.; Klosova, E.; Krtil, J.; Sus, F.; Kuvik, V.; Vrbova, L.; Hamplova, M.; Lengyel, J.; Kelnar, L.; Zakouril, K.

    1990-11-01

    The Central Testing Laboratory of the Nuclear Research Institute at Rez has for a decade been participating in the development of analytical procedures and has been providing analyses of samples of different types and origin. The analytical procedures developed have been published in special journals and a number of them in the Manuals of analytical methods, in three parts. The 4th part of the Manual contains selected physico-chemical methods developed or modified by the Laboratory in the years 1986-1990 within the project ''Development of physico-chemical analytical methods''. In most cases, techniques are involved for non-nuclear applications. Some can find wider applications, especially in analyses of environmental samples. Others have been developed for specific cases of sample analyses or require special instrumentation (mass spectrometer), which partly restricts their applicability by other institutions. (author)

  15. Assessing the Agreement Between Eo-Based Semi-Automated Landslide Maps with Fuzzy Manual Landslide Delineation

    Science.gov (United States)

    Albrecht, F.; Hölbling, D.; Friedl, B.

    2017-09-01

    Landslide mapping benefits from the ever increasing availability of Earth Observation (EO) data resulting from programmes like the Copernicus Sentinel missions and improved infrastructure for data access. However, there arises the need for improved automated landslide information extraction processes from EO data while the dominant method is still manual delineation. Object-based image analysis (OBIA) provides the means for the fast and efficient extraction of landslide information. To prove its quality, automated results are often compared to manually delineated landslide maps. Although there is awareness of the uncertainties inherent in manual delineations, there is a lack of understanding how they affect the levels of agreement in a direct comparison of OBIA-derived landslide maps and manually derived landslide maps. In order to provide an improved reference, we present a fuzzy approach for the manual delineation of landslides on optical satellite images, thereby making the inherent uncertainties of the delineation explicit. The fuzzy manual delineation and the OBIA classification are compared by accuracy metrics accepted in the remote sensing community. We have tested this approach for high resolution (HR) satellite images of three large landslides in Austria and Italy. We were able to show that the deviation of the OBIA result from the manual delineation can mainly be attributed to the uncertainty inherent in the manual delineation process, a relevant issue for the design of validation processes for OBIA-derived landslide maps.

  16. Occupational asthma due to manual metal-arc welding of special stainless steels.

    Science.gov (United States)

    Hannu, T; Piipari, R; Kasurinen, H; Keskinen, H; Tuppurainen, M; Tuomi, T

    2005-10-01

    Occupational asthma (OA) can be induced by fumes of manual metal-arc welding on stainless steel. In recent years, the use of special stainless steels (SSS) with high chromium content has increased. This study presents two cases of OA caused by manual metal-arc welding on SSS. In both cases, the diagnosis of OA was based on respiratory symptoms, occupational exposure and positive findings in the specific challenge tests. In the first case, a 46-yr-old welder had experienced severe dyspnoea while welding SSS (SMO steel), but not in other situations. Challenge tests with both mild steel and stainless steel using a common electrode were negative. Welding SSS with a special electrode caused a delayed 37% drop in forced expiratory volume in one second (FEV1). In the second case, a 34-yr-old male had started to experience dyspnoea during the past few years, while welding especially SSS (Duplex steel). The workplace peak expiratory flow monitoring was suggestive of OA. Challenge tests with both mild steel and stainless steel using a common electrode did not cause bronchial obstruction. Welding SSS with a special electrode caused a delayed 31% drop in FEV1. In conclusion, exposure to manual metal-arc welding fumes of special stainless steel should be considered as a new cause of occupational asthma.

  17. Foot Pedals for Spacecraft Manual Control

    Science.gov (United States)

    Love, Stanley G.; Morin, Lee M.; McCabe, Mary

    2010-01-01

    Fifty years ago, NASA decided that the cockpit controls in spacecraft should be like the ones in airplanes. But controls based on the stick and rudder may not be best way to manually control a vehicle in space. A different method is based on submersible vehicles controlled with foot pedals. A new pilot can learn the sub's control scheme in minutes and drive it hands-free. We are building a pair of foot pedals for spacecraft control, and will test them in a spacecraft flight simulator.

  18. Reconceptualising manual therapy skills in contemporary practice

    DEFF Research Database (Denmark)

    Rabey, Martin; Hall, Toby; Hebron, Clair

    2017-01-01

    With conflicting evidence regarding the effectiveness of manual therapy calls have arisen within some quarters of the physiotherapy profession challenging the continued use of manual skills for assessment and treatment. A reconceptualisation of the importance of manual examination findings is put...

  19. New highway accident location manual for Missouri.

    Science.gov (United States)

    2013-12-01

    The Missouri HAL manual is used to identify, analyze, and correct high crash locations, and has not been updated since : 1999. This new edition brings the manual up to date, while incorporating the methodology of the national Highway Safety : Manual ...

  20. Prospective study establishing a management plan for impacted third molar in patients undergoing hematopoietic stem cell transplantation

    OpenAIRE

    Yamagata, Kenji; Onizawa, Kojiro; Yanagawa, Toru; Takeuchi, Yasutoshi; Hasegawa, Yuichi; Chiba, Shigeru; Bukawa, Hiroki

    2011-01-01

    ObjectiveAlthough dental treatment before hematopoietic stem cell transplantation (HSCT) is essential to prevent serious infections from oral sources, the best management plan for impacted third molar (ITM) is unclear.Study designThis study was planned to establish a management plan for ITM. Eighty-four candidates for HSCT therapy were consecutively enrolled in the prospective trial. The management plan, which was evidence based and prospectively decided, was to extract the symptomatic ITMs a...

  1. Management Information System Project. Data Processors Manual to the Program Oriented Accounting System: The Budgetary Process.

    Science.gov (United States)

    Foley, Walter; Harr, Gordon

    The purpose of this manual is to serve the needs of a data processing facility in the operation of a management information system (MIS). Included in the manual are system flowcharts, job control language, and system documentation. The system has been field tested and operates under IBM System 360/Model 65-05-MVT-HASP. The programing language is…

  2. Comparison between Complementary Dietary Treatment of Alzheimer Disease in Iranian Traditional Medicine and Modern Medicine

    Science.gov (United States)

    AHMADIAN-ATTARI, Mohammad Mahdi; MOSADDEGH, Mahmoud; KAZEMNEJAD, Anooshiravan; NOORBALA, Ahmad Ali

    2013-01-01

    Abstract Background Dietary notifications have been introduced recently for Alzheimer Disease (AD). In Iranian old medical manuscripts, there are some nutritional recommendations related to Nesyan (AD equivalent). The aim of this article was to compare dietary recommendations of Iranian traditional medicine (ITM) with novel medical outcomes. Methods 1) Searching for dietary recommendations and abstinences described in ITM credible manuscripts; 2) Extracting fatty components of ITM diet according to the database of the Department of Agriculture of the USA; 3) Statistical analysis of fatty elements of traditionally recommended foods via Mann-Whitney Test in comparison with elements of the abstinent ones; 4) Searching for AD dietary recommendations and abstinences which currently published in medical journals; 5) Comparing traditional and new dietary suggestions with each other. Results 1) Traditionally recommended foods are fattier than abstinent ones (PTraditionally recommended diet is also fattier than the abstinent diet (4.5 times); UFAs of the recommended diet is 11 times more than that of the abstinent one; it is the same story for cholesterol (1.4 times); 3) Recent studies show that diets with high amounts of UFAs have positive effects on AD; a considerable number of papers emphasizes on probable positive role of cholesterol on AD; 4) Traditional recommended diet is in agreement with recent studies. Conclusion ITM recommended diet which is full of unsaturated fatty acids and cholesterol can be utilized for complementary treatment of AD. PMID:26060643

  3. Aircraft operations management manual

    Science.gov (United States)

    1992-01-01

    The NASA aircraft operations program is a multifaceted, highly diverse entity that directly supports the agency mission in aeronautical research and development, space science and applications, space flight, astronaut readiness training, and related activities through research and development, program support, and mission management aircraft operations flights. Users of the program are interagency, inter-government, international, and the business community. This manual provides guidelines to establish policy for the management of NASA aircraft resources, aircraft operations, and related matters. This policy is an integral part of and must be followed when establishing field installation policy and procedures covering the management of NASA aircraft operations. Each operating location will develop appropriate local procedures that conform with the requirements of this handbook. This manual should be used in conjunction with other governing instructions, handbooks, and manuals.

  4. ETAP user's manual

    International Nuclear Information System (INIS)

    Watanabe, Norio; Higuchi, Suminori.

    1990-11-01

    The event tree analysis technique has been used in Probabilistic Safety Assessment for LWRs to delineate various accident scenarios leading to core melt or containment failure and to evaluate their frequencies. This technique often requires manual preparation of event trees with iterative process and time-consuming work in data handling. For the purpose of reducing manual efforts in event tree analysis, we developed a new software package named ETAP (Event Tree Analysis Supporting Program) for event tree analysis. ETAP is an interactive PC-based program which has the ability to construct, update, document, and quantify event trees. Because of its fast running capability to quantify event trees, use of the EATP program can make it easy to perform the sensitivity studies on a variety of system/containment performance issues. This report provides a user's manual for ETAP, which describes the structure, installation, and use of EATP. This software runs on NEC/PC-9800 or compatible PCs that have a 640 KB memory and MS-DOS 2.11 or higher. (author)

  5. OASIS User Manual

    CERN Document Server

    Bojtar, L

    2009-01-01

    The OASIS system has been operational for years now. After a long development the project has reached a state where the number of features it provides exceeds largely what most of its users knows about. The author felt it was time to write a user manual explaining all the functionality of the viewer application. This document is a user manual, concentrating on the functionality of the viewer from the user’s point of view. There are already documents available on the project’s web site about the technical aspects at http://project-oasis.web.cern.ch/project-oasis/presentations.htm . There was an attempt to produce a tutorial on the viewer, but it didn’t get much further than the table of contents, that however is well thought. The structure of this user manual follows the same principle, the basic and most often used features are grouped together. Advanced or less often used features are described in a separate chapter. There is a second organizational principle, features belong to different levels: chann...

  6. Los Alamos Scientific Laboratory x-ray survey manual

    International Nuclear Information System (INIS)

    Olsher, R.H.

    1980-02-01

    A manual has been developed by the Health Physics Group to establish procedures for routine testing of industrial and analytical x-ray equipment for compliance with applicable LASL administrative requirements and technical bulletins. Radiation protection survey procedures were developed for the following types of equipment: x-ray diffraction and fluorescence analysis systems, industrial cabinet x-ray systems, industrial noncabinet x-ray systems, and electron microscopes

  7. Methane measurements manual; Handbok metanmaetningar

    Energy Technology Data Exchange (ETDEWEB)

    Holmgren, Magnus Andreas (SP Technical research institute of Sweden, Boraas (Sweden))

    2011-02-15

    Emissions to air in different parts of the system may arise in biogas plants, where there is biological treatment of organic matter by anaerobic degradation, and during upgrading of biogas to vehicle fuel. There are mainly four reasons why these emissions must be minimized. These are safety, greenhouse gas emissions, economy and smell. This manual gathers experience of several years of work with measurement of methane emissions from biogas and upgrading facilities. This work has been done mainly in the context of Swedish Waste Management's system of voluntary commitment. The purpose of this manual is to standardize methods and procedures when methane measurements are carried out so that the results are comparable between different providers. The main target group of the manual is measurement consultants performing such measurements. Calculation template in Excel is part of the manual, which further contributes to the measurements evaluated in a standardized way. The manual contains several examples which have been calculated in the accompanying Excel template. The handbook also contains a chapter mainly intended for facility staff, in which implementation of accurate leak detection is described, and where there are hints of a system of so-called intermediate inspections to detect leaks in time

  8. The minimal manual: is less really more?

    NARCIS (Netherlands)

    Lazonder, Adrianus W.; van der Meij, Hans

    1993-01-01

    Carroll, Smith-Kerker, Ford and Mazur-Rimetz (The minimal manual, Human-Computer Interaction , 3, 123-153, 1987) have introduced the minimal manual as an alternative to standard self-instruction manuals. While their research indicates strong gains, only a few attempts have been made to validate

  9. Validating new software for semiautomated liver volumetry. Better than manual measurement?

    Energy Technology Data Exchange (ETDEWEB)

    Noschinski, L.E.; Maiwald, B.; Voigt, P.; Kahn, T.; Stumpp, P. [University Hospital Leipzig (Germany). Dept. of Diagnostic and Interventional Radiology; Wiltberger, G. [University Hospital Leipzig (Germany). Dept. of Visceral, Transplantation, Thoracic and Vascular Surgery

    2015-09-15

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience.

  10. Validating new software for semiautomated liver volumetry. Better than manual measurement?

    International Nuclear Information System (INIS)

    Noschinski, L.E.; Maiwald, B.; Voigt, P.; Kahn, T.; Stumpp, P.; Wiltberger, G.

    2015-01-01

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience.

  11. 76 FR 9020 - Disease, Disability, and Injury Prevention and Control; Special Emphasis Panel (SEP): Ability of...

    Science.gov (United States)

    2011-02-16

    ... Integrated Tick Management (ITM) Technologies To Reduce the Entomological Risk of Lyme Disease, Funding... Tick Management (ITM) Technologies To Reduce the Entomological Risk of Lyme Disease, FOA CK11-005...

  12. Manual on indoor air quality

    International Nuclear Information System (INIS)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues

  13. Manual on indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

  14. 21 CFR 868.1030 - Manual algesimeter.

    Science.gov (United States)

    2010-04-01

    ... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1030 Manual algesimeter. (a) Identification. A manual algesimeter is a mechanical device intended to determine a patient's sensitivity to pain after...

  15. Socioeconomic status affects oral and manual exploration across the first year.

    Science.gov (United States)

    Clearfield, Melissa W; Bailey, Lillian S; Jenne, Helen K; Stanger, Sarah B; Tacke, Nicholas

    2014-01-01

    Oral and manual exploration are part of the foundation of problem solving and cognition in infancy. How these develop in an at-risk population, infants in poverty, is unknown. The current study tested exploratory behaviors longitudinally at 6, 9, and 12 months in infants from high- and low-socioeconomic (SES) families. Oral exploration consisted of passive and active mouthing and looks after active mouthing. Manual exploration consisted of frequency of fingering, rotating, and transferring the object. High-SES infants replicated the trajectory previously reported in the literature, showing a decrease in mouthing and fingering and an increase in rotating and transferring (e.g., Palmer, 1989). In contrast, low-SES infants showed no change in any of the manual exploratory behaviors over the first year, thus demonstrating reduced overall levels of exploration as well as a different developmental trajectory. Results are discussed in terms of attention, potential physiological mechanisms, and implications for later problem solving. © 2013 Michigan Association for Infant Mental Health.

  16. 21 CFR 868.5915 - Manual emergency ventilator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual emergency ventilator. 868.5915 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5915 Manual emergency ventilator. (a) Identification. A manual emergency ventilator is a device, usually incorporating a bag and valve, intended to...

  17. Dental Chairside Technique. Student's Manual.

    Science.gov (United States)

    Apfel, Maura; Weaver, Trudy Karlene

    This manual is part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. This student manual contains four units covering the following topics: local anesthesia; dental office emergencies; oral hygiene;…

  18. Nuclear material operations manual

    International Nuclear Information System (INIS)

    Tyler, R.P.

    1981-02-01

    This manual provides a concise and comprehensive documentation of the operating procedures currently practiced at Sandia National Laboratories with regard to the management, control, and accountability of nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  19. Nuclear material operations manuals

    International Nuclear Information System (INIS)

    Tyler, R.P.

    1979-06-01

    This manual is intended to provide a concise and comprehensive documentation of the operating procedures currently practiced at Sandia Laboratories with regard to the management, control, and accountability of radioactive and nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  20. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    Science.gov (United States)

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  1. Ginger from ancient times to the new outlook.

    Science.gov (United States)

    Khodaie, Laleh; Sadeghpoor, Omid

    2015-02-01

    Ginger is the rhizome of Zingiber officinale, a perennial plant, used alone or in compounds as a spice or remedy in ancient recipes of Iranian traditional medicine (ITM) as an effective tonic for the memory and digestive system, the opener of hepatic obstructions, aphrodisiac, for expelling compact wind from stomach and intestines, diluting, desiccating and emollient of phlegmatic and compact humor sticking to body organs, stomach, intestine, brain and throat. The ITM scholars believed that ginger was a vermifuge as well as a remedy for paralysis and obstructive jaundice. They also revealed that this phytomedicine cures diarrhea due to corrupted food. This study aimed to compare the medicinal properties (afaal) of ginger in ITM with those indicated in modern research. Results of this study showed that the modern phytotherapy confirmed some of the properties of ginger. In addition, some of the properties of this phytomedicine have not been studied yet. By studding the ITM literature, herb elements or in other words ITM keywords, researchers can predict and state some unknown or less known potential pharmacologic effects of medicinal plants.

  2. ASSESSING THE AGREEMENT BETWEEN EO-BASED SEMI-AUTOMATED LANDSLIDE MAPS WITH FUZZY MANUAL LANDSLIDE DELINEATION

    Directory of Open Access Journals (Sweden)

    F. Albrecht

    2017-09-01

    Full Text Available Landslide mapping benefits from the ever increasing availability of Earth Observation (EO data resulting from programmes like the Copernicus Sentinel missions and improved infrastructure for data access. However, there arises the need for improved automated landslide information extraction processes from EO data while the dominant method is still manual delineation. Object-based image analysis (OBIA provides the means for the fast and efficient extraction of landslide information. To prove its quality, automated results are often compared to manually delineated landslide maps. Although there is awareness of the uncertainties inherent in manual delineations, there is a lack of understanding how they affect the levels of agreement in a direct comparison of OBIA-derived landslide maps and manually derived landslide maps. In order to provide an improved reference, we present a fuzzy approach for the manual delineation of landslides on optical satellite images, thereby making the inherent uncertainties of the delineation explicit. The fuzzy manual delineation and the OBIA classification are compared by accuracy metrics accepted in the remote sensing community. We have tested this approach for high resolution (HR satellite images of three large landslides in Austria and Italy. We were able to show that the deviation of the OBIA result from the manual delineation can mainly be attributed to the uncertainty inherent in the manual delineation process, a relevant issue for the design of validation processes for OBIA-derived landslide maps.

  3. TMI cable tracer operation and maintenance manual for assembly 417910

    International Nuclear Information System (INIS)

    Sumstine, R.L.

    1983-11-01

    This manual provides technical information and instructions to operate and maintain the cable tracer designed for the Three Mile Island (TMI) Unit 2 Reactor Building. The TMI cable tracer was developed to allow TMI personnel to trace cables in cable trays that may be tested or sectioned for destructive examination

  4. Geothermal reservoir assessment manual; 1984-1992 nendo chinetsu choryusou hyoka shuhou manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    A geothermal reservoir assessment manual was prepared for the promotion of the development of geothermal power generation, based on the results of the 'geothermal reservoir assessment technique development project' implemented during the fiscal 1984-1992 period and on the results of surveys conducted in Japan and abroad. Of the geothermal systems generally classified into the steam dominant type and the hot water dominant type, encounters with the steam dominant type are but seldom reported. This manual therefore covers the hot water dominant type only. In addition to the explanation of the basic concept and the outline of geothermal reservoirs, the manual carries data necessary for reservoir assessment; geological and geophysical data analyses; geochemistry in reservoir assessment; data of underground logging and of fuming; conceptual models; simulators and models for reservoir simulation; natural-state simulation, history-matching simulation, and reservoir behavior predicting simulation; case history (modeling of a geothermal reservoir prior to exploitation), references, and so forth. (NEDO)

  5. Geothermal reservoir assessment manual; 1984-1992 nendo chinetsu choryusou hyoka shuhou manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    A geothermal reservoir assessment manual was prepared for the promotion of the development of geothermal power generation, based on the results of the 'geothermal reservoir assessment technique development project' implemented during the fiscal 1984-1992 period and on the results of surveys conducted in Japan and abroad. Of the geothermal systems generally classified into the steam dominant type and the hot water dominant type, encounters with the steam dominant type are but seldom reported. This manual therefore covers the hot water dominant type only. In addition to the explanation of the basic concept and the outline of geothermal reservoirs, the manual carries data necessary for reservoir assessment; geological and geophysical data analyses; geochemistry in reservoir assessment; data of underground logging and of fuming; conceptual models; simulators and models for reservoir simulation; natural-state simulation, history-matching simulation, and reservoir behavior predicting simulation; case history (modeling of a geothermal reservoir prior to exploitation), references, and so forth. (NEDO)

  6. Light-water-reactor hydrogen manual

    International Nuclear Information System (INIS)

    Camp, A.L.; Cummings, J.C.; Sherman, M.P.; Kupiec, C.F.; Healy, R.J.; Caplan, J.S.; Sandhop, J.R.; Saunders, J.H.

    1983-06-01

    A manual concerning the behavior of hydrogen in light water reactors has been prepared. Both normal operations and accident situations are addressed. Topics considered include hydrogen generation, transport and mixing, detection, and combustion, and mitigation. Basic physical and chemical phenomena are described, and plant-specific examples are provided where appropriate. A wide variety of readers, including operators, designers, and NRC staff, will find parts of this manual useful. Different sections are written at different levels, according to the most likely audience. The manual is not intended to provide specific plant procedures, but rather, to provide general guidance that may assist in the development of such procedures

  7. 21 CFR 872.6855 - Manual toothbrush.

    Science.gov (United States)

    2010-04-01

    ... remove adherent plaque and food debris from the teeth to reduce tooth decay. (b) Classification. Class I... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6855 Manual toothbrush. (a) Identification. A manual...

  8. 14 CFR 125.75 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 125.75 Section 125... OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD CAPACITY OF 6... Airplane flight manual. (a) Each certificate holder shall keep a current approved Airplane Flight Manual or...

  9. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  10. Kinesiology Workbook and Laboratory Manual.

    Science.gov (United States)

    Harris, Ruth W.

    This manual is written for students in anatomy, kinesiology, or introductory biomechanics courses. The book is divided into two sections, a kinesiology workbook and a laboratory manual. The two sections parallel each other in content and format. Each is divided into three corresponding sections: (1) Anatomical bases for movement description; (2)…

  11. Manual stapedotomy still holds good in the era of laser.

    Science.gov (United States)

    Ganesan, Sivaraman; Anuprasad, S; Patra, Sisir Kumar; Parida, Pradipta Kumar; Gopalakrishnan, Suria; Verma, Nishikanta

    2010-03-01

    In the present era of stapedotomy, there is an inevitable role for laser. But the conventional technique with manual burr still has its own merits in various settings such as usage in resource poor setting in developing countries and avoidance of laser hazards. To evaluate the audiometric outcomes after manual stapedotomy. The present study was retrospective record-based study. Patients who have been diagnosed otosclerosis and those who were not willing for surgery with laser, but gave consent for manual stapedotomy were included for the study. Preoperatively, and at each subsequent post-operative follow-up visits, patients were required to undergo a pure-tone audiogram. The air-bone gaps at the end of 6 months were used for final analysis. Data was analyzed with using Statistical Package for Social Sciences (SPSS) version 12 (Chicago, IL, USA). Descriptive frequency distributions, mean, standard deviation of audiometric data were calculated. The paired t test was done to see the improvement in the air bone gap post-operatively. The mean age of presentation is 32.2 years. Overall, the male:female ratio was found to be 1:1.2. Post-operative air bone closure to 15 decibels was obtained in 80% of patients. There was no significant correlation between the pre-operative hearing loss and post-operative gain, age, and gender of distribution of focus. The post-operative hearing after stapedotomy has been remarkable in all the patients even with manual burr. There were no major vestibular complications in any of these patients. The study has shown that the significant post-operative hearing results can be still achieved with meticulous surgery by an experienced surgeon with manual burr in the present laser era.

  12. Tank waste remediation system process engineering instruction manual

    International Nuclear Information System (INIS)

    ADAMS, M.R.

    1998-01-01

    The purpose of the Tank Waste Remediation System (TWRS) Process Engineering Instruction Manual is to provide guidance and direction to TWRS Process Engineering staff regarding conduct of business. The objective is to establish a disciplined and consistent approach to business such that the work processes within TWRS Process Engineering are safe, high quality, disciplined, efficient, and consistent with Lockheed Martin Hanford Corporation Policies and Procedures. The sections within this manual are of two types: for compliance and for guidance. For compliance sections are intended to be followed per-the-letter until such time as they are formally changed per Section 2.0 of this manual. For guidance sections are intended to be used by the staff for guidance in the conduct of work where technical judgment and discernment are required. The guidance sections shall also be changed per Section 2.0 of this manual. The required header for each manual section is illustrated in Section 2.0, Manual Change Control procedure. It is intended that this manual be used as a training and indoctrination resource for employees of the TWRS Process Engineering organization. The manual shall be required reading for all TWRS Process Engineering staff, matrixed, and subcontracted employees

  13. Radiology Aide. Instructor Key [and] Student Manual.

    Science.gov (United States)

    Hartwein, Jon; Dunham, John

    This manual can be used independently by students in secondary health occupations programs or by persons receiving on-the-job training in a radiology department. The manual includes an instructor's key that provides answers to the activity sheets and unit evaluations. The manual consists of the following five units: (1) orientation to radiology;…

  14. Influence of manual therapy on functional mobility after joint injury in a rat model.

    Science.gov (United States)

    Ruhlen, Rachel L; Snider, Eric J; Sargentini, Neil J; Worthington, Bart D; Singh, Vineet K; Pazdernik, Vanessa K; Johnson, Jane C; Degenhardt, Brian F

    2013-10-01

    Animal models can be used to investigate manual therapy mechanisms, but testing manipulation in animal models is problematic because animals cannot directly report their pain. To develop a rat model of inflammatory joint injury to test the efficacy of manual therapy in reducing nociception and restoring function. The authors induced acute inflammatory joint injury in rats by injecting carrageenan into the ankle and then measured voluntary running wheel activity in treated and untreated rats. Treatments included manual therapy applied to the ankle and knee of the injured limb and several analgesic medications (eg, morphine, ketorolac, prednisone). Intra-articular injection of carrageenan to the ankle produced significant swelling (diameter of the ankle increased by 64% after injection; P=.004) and a robust reduction in voluntary running wheel activity (running distance reduced by 91% compared with controls; Pmanual therapy nor analgesic medications increased running wheel activity relative to untreated rats. Voluntary running wheel activity appears to be an appropriate functional measure to evaluate the impact of an acute inflammatory joint injury. However, efforts to treat the injury did not restore running relative to untreated rats.

  15. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    International Nuclear Information System (INIS)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.; Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G.

    2015-01-01

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy

  16. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Takaki, H. [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States); Laskhmanan, M. [Perfint Healthcare Inc (India); Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G., E-mail: srimaths@mskcc.org [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States)

    2015-10-15

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

  17. Nuclear material operations manual

    International Nuclear Information System (INIS)

    Tyler, R.P.; Gassman, L.D.

    1978-04-01

    This manual is intended to provide a concise and comprehensive documentation of the operating procedures currently practiced at Sandia Laboratories with regard to the management, control, and accountability of radioactive and nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations--management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of ''play-scripts'' in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  18. WAM-E user's manual

    International Nuclear Information System (INIS)

    Rayes, L.G.; Riley, J.E.

    1986-07-01

    The WAM-E series of mainframe computer codes have been developed to efficiently analyze the large binary models (e.g., fault trees) used to represent the logic relationships within and between the systems of a nuclear power plant or other large, multisystem entity. These codes have found wide application in reliability and safety studies of nuclear power plant systems. There are now nine codes in the WAM-E series, with six (WAMBAM/WAMTAP, WAMCUT, WAMCUT-II, WAMFM, WAMMRG, and SPASM) classified as Type A Production codes and the other three (WAMFTP, WAMTOP, and WAMCONV) classified as Research codes. This document serves as a combined User's Guide, Programmer's Manual, and Theory Reference for the codes, with emphasis on the Production codes. To that end, the manual is divided into four parts: Part I, Introduction; Part II, Theory and Numerics; Part III, WAM-E User's Guide; and Part IV, WAMMRG Programmer's Manual

  19. Robotic Assistance by Impedance Compensation for Hand Movements While Manual Welding.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2016-11-01

    In this paper, we present a robotic assistance scheme which allows for impedance compensation with stiffness, damping, and mass parameters for hand manipulation tasks and we apply it to manual welding. The impedance compensation does not assume a preprogrammed hand trajectory. Rather, the intention of the human for the hand movement is estimated in real time using a smooth Kalman filter. The movement is restricted by compensatory virtual impedance in the directions perpendicular to the estimated direction of movement. With airbrush painting experiments, we test three sets of values for the impedance parameters as inspired from impedance measurements with manual welding. We apply the best of the tested sets for assistance in manual welding and perform welding experiments with professional and novice welders. We contrast three conditions: 1) welding with the robot's assistance; 2) with the robot when the robot is passive; and 3) welding without the robot. We demonstrate the effectiveness of the assistance through quantitative measures of both task performance and perceived user's satisfaction. The performance of both the novice and professional welders improves significantly with robotic assistance compared to welding with a passive robot. The assessment of user satisfaction shows that all novice and most professional welders appreciate the robotic assistance as it suppresses the tremors in the directions perpendicular to the movement for welding.

  20. Vehicle access and search training manual. Report for Oct 77-sep 79

    International Nuclear Information System (INIS)

    Obermiller, J.E.; Wait, H.J.

    1979-11-01

    This Vehicle Access and Search Training Manual is intended to assist NRC-licensed organizations and their security personnel in developing vehicle access, control and search operations necessary at nuclear fuel cycle facilities and at reactor facilities. The manual is based on security requirements prescribed by The Nuclear Regulatory Commission as contained in Title 10 of the Code of Federal Regulations, Part 73, 'Physical Protection of Plants and Materials.' As a condition of the licensing agreement, the licensee is required to maintain a physical protection system which includes a training program for security personnel. The manual includes lesson plans in (1) controlling vehicle entry and exit, (2) searching for contraband, and (3) protecting the facility from sabotage and/or theft of special nuclear materials. These training guidelines provide information and instruction for self-study, discussion and hands-on training. A job knowledge test reviews the entire training program

  1. Managerial Accounting. Course Administrative Manual.

    Science.gov (United States)

    Central Michigan Univ., Mount Pleasant. Inst. for Personal and Career Development.

    This manual is part of the materials for a college-level programmed course in managerial accounting and intended to aid instructors in helping students to work their way through the self-instructional study guide around which the course is organized. The manual describes the various materials and components used in the self-instructional sequence…

  2. The Influence of Hand Immersion Duration on Manual Performance.

    Science.gov (United States)

    Ray, Matthew; Sanli, Elizabeth; Brown, Robert; Ennis, Kerri Ann; Carnahan, Heather

    2017-08-01

    To investigate the effect of hand immersion duration on manipulative ability and tactile sensitivity. Individuals in maritime settings often work with hands that have been immersed in water. Although research has shown that hand immersion duration differentially impacts skin adhesion and tactile sensitivity, the effect of hand immersion on manipulative ability has not been directly tested. Given how critical manipulative ability is for the safety and performance of those working at sea, the effect of hand immersion duration on manual performance was investigated. Tests of manipulative ability (Purdue Pegboard, Grooved Pegboard, reef knot untying) and tactile sensitivity (Touch-Test) were completed following no-exposure, short-exposure, and long-exposure hand immersions in thermoneutral water. Compared to the no immersion condition, the Purdue Pegboard performance was reduced in both immersion conditions (short exposure, -11%; long exposure, -8%). A performance decrement was only observed in the short exposure condition (+15% in time to complete task) for the reef knot untying task. There were no statistical differences in the Grooved Pegboard or Touch-Test scores between exposure conditions. Immersing the hands in water decreases manipulative ability except for when object properties reduce the slipperiness between the hand and object. Manual performance in a wet environment may be conserved by designing tools and objects with edges and textures that can offset the slipperiness of wet hands. To maintain safety, the time requirements for working with wet hands needs to be considered.

  3. Radiological Control Manual. Revision 0, January 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  4. Fluor Hanford Nuclear Material Stabilization Project Welding Manual

    International Nuclear Information System (INIS)

    BERKEY, J.R.

    2000-01-01

    The purpose of this section of the welding manual is to: (1) Provide a general description of the major responsibilities of the organizations involved with welding. (2) Provide general guidance concerning the application of codes related to welding. This manual contains requirements for welding for all Fluor Hanford (FH) welding operators working on the W460 Project, in the Plutonium Finishing Plant (PFP) at the U. S. Department of Energy (DOE) Hanford facilities. These procedures and any additional requirements for these joining processes can be used by all FH welding operators that are qualified. The Welding Procedure Specifications (WPS) found in this document were established from Procedure Qualification Records (PQR) qualified by FH specifically for the W460 Project. PQRs are permanent records of the initial testing and qualification program and are used to backup, and support, the WPS. The identification numbers of the supporting PQR(s) are recorded on each WPS. All PQRs are permanently stored under the supervision of the Fluor Hanford Welding Engineer (FHWE). New PQRs and WPSs will continue to be developed as necessary. The qualification of welders, welding operators and welding procedures will be performed for FH under supervision and concurrent of the FHWE. All new welding procedures to be entered in this manual or welder personnel to be added to the welder qualification database, shall be approved by the FHWE

  5. The Manual Work Instability Scale: development and validation.

    Science.gov (United States)

    Gilworth, G; Smyth, M G; Smith, J; Tennant, A

    2016-06-01

    Increasing awareness of the burden of absenteeism and reduced performance at work highlights the importance of early identification of individuals experiencing work instability (WI), a mismatch between functional and cognitive abilities and job demands. To develop and validate a screening questionnaire to measure WI in manual workers. Questionnaire items were generated via qualitative interviews with manual workers and a draft survey instrument was completed by workers in a variety of fields. Rasch analysis was used interactively to assess the psychometric aspects of the emerging scale, including unidimensionality and absence of item bias (differential item functioning). A total of 17 qualitative interviews generated 110 potential items for the questionnaire. The item set resolved to a 25-item scale, which satisfied model expectations (item residual mean = -0.13, SD = 1.04; person residual mean = -0.29, SD = 0.75), had good reliability (alpha = 0.86) and strict unidimensionality (t-test 7.5% confidence interval 3.8-11.2). The Manual Work Instability Scale is a short psychometrically robust questionnaire based on the concept of WI, which incorporates both musculoskeletal symptoms and relevant psychosocial factors. It may prove effective in screening and identifying WI in workers in predominantly physical occupations. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Users Manual for the FEHMN application

    International Nuclear Information System (INIS)

    Zyvoloski, G.A.; Robinson, B.A.; Dash, Z.V.; Trease, L.L.

    1996-01-01

    The user's manual documents the use of the Yucca Mountain Site Characterization Projects Finite element heat and mass transfer code (FEHMN) application. The manual covers: Program considerations, data files, input data, output, system interface, and examples

  7. Automated reactor protection testing saves time and avoids errors

    International Nuclear Information System (INIS)

    Raimondo, E.

    1990-01-01

    When the Pressurized Water Reactor units in the French 900MWe series were designed, the instrumentation and control systems were equipped for manual periodic testing. Manual reactor protection system testing has since been successfully replaced by an automatic system, which is also applicable to other instrumentation testing. A study on the complete automation of process instrumentation testing has been carried out. (author)

  8. A metronome for pacing manual ventilation in a neonatal resuscitation simulation.

    Science.gov (United States)

    Cocucci, Cecilia; Madorno, Matías; Aguilar, Adriana; Acha, Leila; Szyld, Edgardo; Musante, Gabriel

    2015-01-01

    During manual positive pressure ventilation (PPV), delivering a recommended respiratory rate (RR) is operator dependent. We tested the efficacy of a metronome as a standardised method to improve the accuracy of delivered RR during manual PPV in a neonatal resuscitation simulation. We conducted a blinded simulation in two consecutive stages. Using a self-inflating bag, 36 CPR trained operators provided PPV to a modified neonatal manikin via an endotracheal tube. Pressure and flow signals were captured by a respiratory function monitor. In the first standard stage, participants delivered RR as they would in delivery room. Prior to the second stage, they were asked about what their target RR had been and a metronome was set to that target. Subsequently, operators repeated PPV attempting to coordinate their delivered RR with the metronome. To evaluate accuracy we generated the variable RR Gap as the absolute difference between delivered and target RR. The primary outcome was the difference in RR Gap between stages. Mean (SD) target RR was 50 (8.7) inflations/min. During the initial stage, median (IQR) RR Gap was 11.6 (4.7-18.3) inflations/min and 20/36 participants (55.5%) had a mean delivered RR beyond the recommended range. When paced by the metronome, RR Gap was reduced to 0.2 (0.1-0.4) inflations/min and 32/36 participants (89%) fell within the recommended range. The use of a metronome improved the accuracy of delivered RR during manual PPV. Novel approaches to deliver an accurate RR during manual PPV need to be tested in more realistic scenarios. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Development of an environmental safety case guidance manual

    International Nuclear Information System (INIS)

    Wellstead, Matthew John

    2014-01-01

    NDA RWMD is currently considering the scope, purpose and structure of a safety case manual that covers the development of nuclear operational, transport and environmental safety cases for a geological disposal facility in the United Kingdom. This paper considers the Environmental Safety Case (ESC) input into such a manual (herein referred to as the 'ESC Manual'), looking at the drivers and benefits that a guidance manual in this area may provide. (authors)

  10. How does the Augmented Reality Manual enhance cognitive activity while doing complex maintenance tasks?: Augmented Tutorial Overlaid Manual (ATOM)

    International Nuclear Information System (INIS)

    Yim, Ho Bin; Seong, Poong Hyun

    2008-01-01

    It has been more than a decade since the concept of Augmented Reality (AR) was introduced. Many related technologies, such as tracking and display, to animate this concept have improved to certain levels. AR is well suited for interaction with the cognitive vision system. In contrast to the virtual reality, AR applications enrich the perceived reality with additional visual information which ranges from text annotation and object highlighting to complex 3D objects. AR has been tested its potentiality in various forms of applications. For example, visitors wear Head Mount Display (HMD) to see virtual guides explaining artifacts in a museum or soldiers are informed geographical features about unfamiliar operation sites. Recently, researchers tried to use AR as a means of teaching or training apparatus; however, there are still some technical obstacles to put this fascinating technology into practice. In this study, we will use Cognitive Load Theory (CLT) to design a manual of pump maintenance and convert it to AR technology to propose a proto type of an on-line AR maintenance manual to prove its possibility as an interactive learning tool

  11. How does the Augmented Reality Manual enhance cognitive activity while doing complex maintenance tasks?: Augmented Tutorial Overlaid Manual (ATOM)

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Ho Bin; Seong, Poong Hyun [Korea Advanced Institute of Technology and Science, Daejeon (Korea, Republic of)

    2008-10-15

    It has been more than a decade since the concept of Augmented Reality (AR) was introduced. Many related technologies, such as tracking and display, to animate this concept have improved to certain levels. AR is well suited for interaction with the cognitive vision system. In contrast to the virtual reality, AR applications enrich the perceived reality with additional visual information which ranges from text annotation and object highlighting to complex 3D objects. AR has been tested its potentiality in various forms of applications. For example, visitors wear Head Mount Display (HMD) to see virtual guides explaining artifacts in a museum or soldiers are informed geographical features about unfamiliar operation sites. Recently, researchers tried to use AR as a means of teaching or training apparatus; however, there are still some technical obstacles to put this fascinating technology into practice. In this study, we will use Cognitive Load Theory (CLT) to design a manual of pump maintenance and convert it to AR technology to propose a proto type of an on-line AR maintenance manual to prove its possibility as an interactive learning tool.

  12. No difference between mechanical perturbation training with compliant surface and manual perturbation training on knee functional performance after ACL rupture.

    Science.gov (United States)

    Nawasreh, Zakariya; Logerstedt, David; Failla, Mathew; Snyder-Mackler, Lynn

    2017-10-27

    Manual perturbation training improves dynamic knee stability and functional performance after anterior cruciate ligament rupture (ACL-rupture). However, it is limited to static standing position and does not allow time-specific perturbations at different phase of functional activities. The purpose of this study was to investigate whether administering mechanical perturbation training including compliant surface provides effects similar to manual perturbation training on knee functional measures after an acute ACL-rupture. Sixteen level I/II athletes with ACL-ruptures participated in this preliminary study. Eight patients received mechanical (Mechanical) and eight subjects received manual perturbation training (Manual). All patients completed a functional testing (isometric quadriceps strength, single-legged hop tests) and patient-reported measures (Knee Outcome Survey-Activities of Daily Living Scale (KOS-ADLS), Global Rating Score (GRS), International Knee Documentation Committee 2000 (IKDC 2000) at pre- and post-training. 2 × 2 ANOVA was used for data analysis. No significant group-by-time interactions were found for all measures (p > 0.18). Main effects of time were found for single hop (Pre-testing: 85.14% ± 21.07; Post-testing: 92.49% ± 17.55), triple hop (Pre-testing: 84.64% ± 14.17; Post-testing: 96.64% ± 11.14), KOS-ADLS (Pre-testing: 81.13% ± 11.12; Post-testing: 88.63% ± 12.63), GRS (Pre-testing: 68.63% ± 15.73; Post-testing: 78.81% ± 13.85), and IKDC 2000 (Pre-testing: 66.66% ± 9.85; Post-testing: 76.05% ± 14.62) (p training using compliant surfaces induce effects similar to manual perturbation training on knee functional performance after acute ACL-rupture. The clinical significance is both modes of training improve patients' functional-performance and limb-to-limb movement symmetry, and enhancing the patients' self-reported of knee functional measures after ACL rupture. Mechanical

  13. Developing Basic Math Skills for Marketing. Student Manual and Laboratory Guide.

    Science.gov (United States)

    Klewer, Edwin D.

    Field tested with students in grades 10-12, this manual is designed to teach students in marketing courses basic mathematical concepts. The instructional booklet contains seven student assignments covering the following topics: why basic mathematics is so important, whole numbers, fractions, decimals, percentages, weights and measures, and dollars…

  14. Site security personnel training manual

    International Nuclear Information System (INIS)

    1978-10-01

    As required by 10 CFR Part 73, this training manual provides guidance to assist licensees in the development of security personnel training and qualifications programs. The information contained in the manual typifies the level and scope of training for personnel assigned to perform security related tasks and job duties associated with the protection of nuclear fuel cycle facilities and nuclear power reactors

  15. Radiation protection manual

    International Nuclear Information System (INIS)

    Spang, A.

    1983-01-01

    According to the Radiation Protection Ordinance, radiation protection experts directing or supervising the handling of radioactive materials must have expert knowledge. The concept of expert knowledge has been clearly defined by the Fachverband e.V. in a catalogue of instruction goals. The manual follows the principles of this catalogue; it presents the expert knowledge required in a total of 15 subject groups. There is an index which helps the reader to find his specific subject group and the knowledge required of him in this subject group. However, the manual gives only an outline of the subject matter in many instances and should therefore not be regarded as a textbook in the proper sense. (orig./HP) [de

  16. Gravel Roads: Maintenance and Design Manual

    Science.gov (United States)

    This manual was developed with a major emphasis on the maintenance of gravel roads, including some basic design elements. The purpose of the manual is to provide clear and helpful information for doing a better job of maintaining gravel roads.

  17. Radar and ARPA manual

    CERN Document Server

    Bole, A G

    2013-01-01

    Radar and ARPA Manual focuses on the theoretical and practical aspects of electronic navigation. The manual first discusses basic radar principles, including principles of range and bearing measurements and picture orientation and presentation. The text then looks at the operational principles of radar systems. Function of units; aerial, receiver, and display principles; transmitter principles; and sitting of units on board ships are discussed. The book also describes target detection, Automatic Radar Plotting Aids (ARPA), and operational controls of radar systems, and then discusses radar plo

  18. HASL procedures manual

    International Nuclear Information System (INIS)

    Harley, J.H.

    1977-08-01

    Additions and corrections to the following sections of the HASL Procedures Manual are provided: General, Sampling, Field Measurements; General Analytical Chemistry, Chemical Procedures, Data Section, and Specifications

  19. Should Social Workers Use "Diagnostic and Statistical Manual of Mental Disorders-5?"

    Science.gov (United States)

    Frances, Allen; Jones, K. Dayle

    2014-01-01

    Up until now, social workers have depended on the "Diagnostic and Statistical Manual of Mental Disorders" ("DSM") as the primary diagnostic classification for mental disorders. However, the "DSM-5" revision includes scientifically unfounded, inadequately tested, and potentially dangerous diagnoses that may lead them…

  20. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650.... This generic type of device may include patient and equipment supports, component parts, treatment...

  1. Waste Management Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Buckingham, J.S. [ed.

    1967-08-31

    This Manual has been prepared to provide a documented compendium of the technical bases and general physical features of Isochem Incorporated`s Waste Management Program. The manual is intended to be used as a means of training and as a reference handbook for use by personnel responsible for executing the Waste Management Program. The material in this manual was assembled by members of Isochem`s Chemical Processing Division, Battelle Northwest Laboratory, and Hanford Engineering Services between September 1965 and March 1967. The manual is divided into the following parts: Introduction, contains a summary of the overall Waste Management Program. It is written to provide the reader with a synoptic view and as an aid in understanding the subsequent parts; Feed Material, contains detailed discussion of the type and sources of feed material used in the Waste Management Program, including a chapter on nuclear reactions and the formation of fission products; Waste Fractionization Plant Processing, contains detailed discussions of the processes used in the Waste Fractionization Plant with supporting data and documentation of the technology employed; Waste Fractionization Plant Product and Waste Effluent Handling, contains detailed discussions of the methods of handling the product and waste material generated by the Waste Fractionization Plant; Plant and Equipment, describes the layout of the Waste Management facilities, arrangement of equipment, and individual equipment pieces; Process Control, describes the instruments and analytical methods used for process control; and Safety describes process hazards and the methods used to safeguard against them.

  2. Medicinal Herbs in Iranian Traditional Medicine for Learning and Memory.

    Science.gov (United States)

    Shojaii, Asie; Ghods, Roshanak; Fard, Mehri Abdollahi

    2016-05-01

    A few factors such as age, stress, and emotions may lead to impaired learning, memory loss, amnesia, and dementia or threats like schizophrenia and Alzheimer's disease (AD). Iranian traditional medicine (ITM) recommends some herbs and herbal preparations for the treatment or prevention of CNS problems. In this study, scientific evidence related to the effectiveness of ITM herbal medicine on memory, learning and AD is reviewed. The scientific evidence of plant efficacy was searched in electronic databases including PubMed, Scopus, SID, Science Direct, and Google Scholar by keywords such as memory, Alzheimer, amnesia, learning and scientific plant names from 1969 to 2014. The findings of this study confirmed the effectiveness of certain ITM medicinal plants on enhancing memory and learning or in the treatment/prevention of amnesia and AD. Some ITM plants like Melissa officinalis, Crocus sativus and Nigella sativa showed improving effects on memory and the treatment of AD in clinical trials. In some cases, active principles responsible for the efficacy of these plants on memory were also determined. Most of the studies on ITM plants were designed in animal models and a few herbs were evaluated in clinical trials on AD. Furthermore, there are insufficient or no investigations on certain herbal medicines used in ITM to confirm their effectiveness on memory and learning. Therefore, further experimental and clinical studies are necessary to evaluate the effectiveness of these plants on memory and AD as well as determining their active components.

  3. Quality assurance program manual for nuclear power plants. Volume I. Policies

    International Nuclear Information System (INIS)

    1976-01-01

    The Consumers Power Company Quality Assurance Program Manual for Nuclear Power Plants consists of policies and procedures which comply with current NRC regulatory requirements and industry codes and standards in effect during the design, procurement, construction, testing, operation, refueling, maintenance, repair and modification activities associated with nuclear power plants. Specific NRC and industry documents that contain the requirements, including the issue dates in effect, are identified in each nuclear power plant's Safety Analysis Report. The requirements established by these documents form the basis for the Consumer Power Quality Assurance Program, which is implemented to control those structures, systems, components and operational safety actions listed in each nuclear power plant's Quality List (Q-List). As additional and revised requirements are issued by the NRC and professional organizations involved in nuclear activities, they will be reviewed for their impact on this manual, and changes will be made where considered necessary. CP Co 1--Consumers Power Company QA Program Topical Report is Volume I of this manual and contains Quality Assurance Program Policies applicable during all phases of nuclear power plant design, construction and operation

  4. US Department of Energy radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE`s positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements.

  5. The participation of NMDA receptors, PKC, and MAPK in the formation of memory following operant conditioning in Lymnaea

    Directory of Open Access Journals (Sweden)

    Rosenegger David

    2010-08-01

    Full Text Available Abstract Background Memory is the ability to store, retain, and later retrieve information that has been learned. Intermediate term memory (ITM that persists for up to 3 h requires new protein synthesis. Long term memory (LTM that persists for at least 24 h requires: DNA transcription, RNA translation, and the trafficking of newly synthesized proteins. It has been shown in a number of different model systems that NMDA receptors, protein kinase C (PKC and mitogen activated protein kinase (MAPK are all involved in the memory formation process. Results Here we show that snails trained in control conditions are capable of forming, depending on the training procedure used, either ITM or LTM. However, blockage of NMDA receptors (MK 801, inhibition of PKC (GF109203X hydrochloride and MAPK activity (UO126 prevent the formation of both ITM and LTM. Conclusions The injection of either U0126 or GF109203X, which inhibit MAPK and PKC activity respectively, 1 hour prior to training results in the inhibition of both ITM and LTM formation. We further found that NMDA receptor activity was necessary in order for both ITM and LTM formation.

  6. Mental retardation-related protease, motopsin (prss12), binds to the BRICHOS domain of the integral membrane protein 2a.

    Science.gov (United States)

    Mitsui, Shinichi; Osako, Yoji; Yuri, Kazunari

    2014-01-01

    Motopsin (prss12), a mosaic serine protease secreted by neuronal cells, is believed to be important for cognitive function, as the loss of its function causes severe nonsyndromic mental retardation. To understand the molecular role of motopsin, we identified the integral membrane protein 2a (Itm2a) as a motopsin-interacting protein using a yeast two-hybrid system. A pull-down assay showed that the BRICHOS domain of Itm2a was essential for this interaction. Motopsin and Itm2a co-localized in COS cells and in cultured neurons when transiently expressed in these cells. Both proteins were co-immunoprecipitated from lysates of these transfected COS cells. Itm2a was strongly detected in a brain lysate prepared between postnatal day 0 and 10, during which period motopsin protein was also enriched in the brain. Immunohistochemistry detected Itm2a as patchy spots along endothelial cells of brain capillaries (which also expressed myosin II regulatory light chain [RLC]), and on glial fibrillary acidic protein (GFAP)-positive processes in the developing cerebral cortex. The data raise the possibility that secreted motopsin interacts with endothelial cells in the developing brain. © 2013 International Federation for Cell Biology.

  7. Suitability of a magnetic particle immunoassay for the analysis of PBDEs in Hawaiian euryhaline fish and crabs in comparison with gas chromatography/electron capture detection-ion trap mass spectrometry

    International Nuclear Information System (INIS)

    Xu Ting; Cho, Il Kyu; Wang Dongli; Rubio, Fernando M.; Shelver, Weilin L.; Gasc, Anne M.E.; Li, Ji; Li, Qing X.

    2009-01-01

    A gas chromatograph/electron capture detector-ion trap mass spectrometer (GC/ECD-ITMS) was used for the determination of polybrominated diphenyl ethers (PBDEs) in euryhaline fish and crabs. GC/ECD-ITMS results showed that average recoveries from the spiked fish samples are in a range of 58-123% with relative standard deviations (RSDs) of 5-19%. PBDE concentrations obtained from GC/ECD-ITMS ranged from 28 ng/g to 1845 ng/g lipid weight (lw) in all aquatic species collected from Hawaiian brackish waters. The general BDE congener concentration profile observed in this study is BDE-47 > BDE-100 > BDE-154 > BDE-99 > BDE-153 > BDE-28 > BDE-183. The ELISA results expressed as BDE-47 equivalents correlated well with those of GC/ECD-ITMS, with a correlation coefficient (R 2 = 0.68) and regression coefficient (slope = 0.82). Comparison of ELISA with GC/ECD-ITMS results demonstrated that ELISA provides a timely and cost-effective method to screen PBDEs in fish and crab samples. - PBDEs (with the most abundant being BDE-47) at concentrations of 28-1845 ng/g lipid weight in fish and crabs from Hawaiian freshwater were detected with both ELISA and GC/MS

  8. Common Manual Therapy Practices in the Netherlands for Infants With Upper Cervical Dysfunction: A Prospective Cohort Study.

    Science.gov (United States)

    Saedt, Eric R I C; Driehuis, Femke; Hoogeboom, Thomas J; van der Woude, Bé H; de Bie, Rob A; Nijhuis-van der Sanden, Maria W G

    2018-01-01

    The purpose of this study was to describe common clinical practices of manual therapists (MTs) in the Netherlands for infants with indications of upper cervical dysfunction (UCD). A prospective observational cohort study was conducted to gain insight into characteristics, reasons for seeking care, and common clinical practice for infants (<27 weeks) with indications of UCD, referred to MTs. Pre- and posttreatment self-reported questionnaires were used to collect data from parents and MTs. Parents reported on infant characteristics and perceived effect of treatment. Manual therapists reported on diagnostics, therapeutic procedures, and outcomes. Between 2006 and 2007, data regarding 307 referred infants (mean age: 11.2 weeks) were collected by parents and 42 MTs. The most frequent reasons for seeking care were positional preference, restlessness, and/or abnormal head position. Manual therapists observed active, spontaneous, and provoked mobility and passive upper cervical mobility. Of the 307 infants, 295 were diagnosed with UCD based on positive outcomes on the flexion-rotation test and/or lateral flexion test. After treatment with mobilization techniques, positive outcomes on the flexion-rotation test decreased from 78.8% to 6.8%. For the lateral flexion test, the positive outcomes decreased from 91.5% to 6.2%. All parents perceived positive treatment effects. No serious adverse events were reported during this study. This is the first study to describe common clinical practice for infants referred for manual therapy. Infants with UCD were treated mainly with upper cervical mobilization techniques, and the greatest perceived effect was observed after approximately 2 treatment sessions. Copyright © 2018. Published by Elsevier Inc.

  9. Evaluation of the Swedish version of the Child Drawing: Hospital Manual.

    Science.gov (United States)

    Wennström, Berith; Nasic, Salmir; Hedelin, Hans; Bergh, Ingrid

    2011-05-01

    This paper is a report of psychometric testing of the Swedish version of the Child Drawing: Hospital Manual. Drawings have shown to be useful in assessing emotional status and anxiety in children because they generally speak to us more clearly and openly through their drawings than they are willing or able to verbally. The Child Drawing: Hospital Manual was translated into Swedish according to World Health Organization guidelines (a routine procedure for translation of English instruments) in order to assess anxiety by analysing the drawings of 59 children (5-11 years), of whom nine were girls and 50 boys undergoing day surgery during 2007-2009. Inter-rater reliability (five independent scorers) was high and internal consistency reliability was good (coefficient alpha =0·77). Parts A and C, as well as the total scale score of the Child Drawing: Hospital Manual, discriminated anxiety significantly between the group of children undergoing day surgery and a comparison group of school children, indicating adequate construct validity. For the Swedish version of the Child Drawing: Hospital Manual, our study demonstrates evidence for adequate construct validity in Parts A and C (and total scale score), high inter-rater reliability and acceptable internal consistency reliability. However, some improvements are needed before the instrument will be a clinically useful assessment of anxiety in children undergoing day surgery. © 2011 Blackwell Publishing Ltd.

  10. Impact of Manually Controlled Solar Shades on Indoor Visual Comfort

    Directory of Open Access Journals (Sweden)

    Jian Yao

    2016-07-01

    Full Text Available Daylight plays a significant role in sustainable building design. The purpose of this paper was to investigate the impact of manual solar shades on indoor visual comfort. A developed stochastic model for manual solar shades was modeled in Building Controls Virtual Test Bed, which was coupled with EnergyPlus for co-simulation. Movable solar shades were compared with two unshaded windows. Results show that movable solar shades have more than half of the working hours with a comfortable illuminance level, which is about twice higher than low-e windows, with a less significant daylight illuminance fluctuation. For glare protection, movable solar shades increase comfortable visual conditions by about 20% compared to low-e windows. Moreover, the intolerable glare perception could be reduced by more than 20% for movable solar shades.

  11. MANUAL LOGIC CONTROLLER (MLC)

    OpenAIRE

    Claude Ziad Bayeh

    2015-01-01

    The “Manual Logic Controller” also called MLC, is an electronic circuit invented and designed by the author in 2008, in order to replace the well known PLC (Programmable Logic Controller) in many applications for its advantages and its low cost of fabrication. The function of the MLC is somewhat similar to the well known PLC, but instead of doing it by inserting a written program into the PLC using a computer or specific software inside the PLC, it will be manually programmed in a manner to h...

  12. Security electronics circuits manual

    CERN Document Server

    MARSTON, R M

    1998-01-01

    Security Electronics Circuits Manual is an invaluable guide for engineers and technicians in the security industry. It will also prove to be a useful guide for students and experimenters, as well as providing experienced amateurs and DIY enthusiasts with numerous ideas to protect their homes, businesses and properties.As with all Ray Marston's Circuits Manuals, the style is easy-to-read and non-mathematical, with the emphasis firmly on practical applications, circuits and design ideas. The ICs and other devices used in the practical circuits are modestly priced and readily available ty

  13. Towards Automatic Capturing of Manual Data Processing Provenance

    NARCIS (Netherlands)

    Wombacher, Andreas; Huq, M.R.

    2011-01-01

    Often data processing is not implemented by a work ow system or an integration application but is performed manually by humans along the lines of a more or less specified procedure. Collecting provenance information during manual data processing can not be automated. Further, manual collection of

  14. Creating Web Sites The Missing Manual

    CERN Document Server

    MacDonald, Matthew

    2006-01-01

    Think you have to be a technical wizard to build a great web site? Think again. For anyone who wants to create an engaging web site--for either personal or business purposes--Creating Web Sites: The Missing Manual demystifies the process and provides tools, techniques, and expert guidance for developing a professional and reliable web presence. Like every Missing Manual, you can count on Creating Web Sites: The Missing Manual to be entertaining and insightful and complete with all the vital information, clear-headed advice, and detailed instructions you need to master the task at hand. Autho

  15. IOLMaster versus Manual Keratometry after Photorefractive Keratectomy

    Directory of Open Access Journals (Sweden)

    Hasan Razmju

    2011-01-01

    Full Text Available Purpose: To compare keratometric measurements using a Javal type manual keratometer with IOLMaster in eyes undergoing photorefractive keratectomy (PRK for myopia. Methods: In this comparative case series, we studied patients aged 21 to 27 years scheduled for myopic PRK. Keratometry was performed preoperatively and three months after the procedure using a Javal type manual keratometer and the IOLMaster. We compared postoperative measurements obtained by both instruments with the clinical history method (CHM. Results: Seventy eyes of 35 patients with mean age of 23.45±1.55 years were studied. Mean preoperative spherical equivalent was -4.53±1.3 D. Average preoperative IOLMaster and manual keratometric readings were 45.95±1.23 D and 46.32±1.18 D, respectively. Postoperatively, mean IOLMaster measurements was 38.03±0.68 D and that of manual keratometry was 43.15±1.1 D. Compared to CHM measurements, the 95% limits of agreement were ‑5.95 to -0.85 for the IOLMaster and -1.44 to 4.04 for manual keratometry. Conclusion: Keratometric measurements with the IOLMaster and a Javal type manual device are comparable after PRK; both are largely deviant from the CHM and can yield misleading results.

  16. Incidence rates of surgically treated rhegmatogenous retinal detachment among manual workers, non-manual workers and housewives in Tuscany, Italy

    OpenAIRE

    Curti, Stefania; Coggon, David; Baldasseroni, Alberto; Cooke, Robin M. T.; Fresina, Michela; Campos, Emilio C.; Semeraro, Francesco; Zanardi, Francesca; Farioli, Andrea; Violante, Francesco S.; Mattioli, Stefano

    2013-01-01

    Purpose Candidate risk factors for idiopathic rhegmatogenous retinal detachment (RRD) include heavy manual handling (requiring Valsalva’s maneuver). We assessed incidence rates of surgically treated idiopathic RRD among manual workers, non-manual workers and housewives resident in Tuscany, Italy. Methods We retrieved all hospital discharge records bearing a principal diagnosis corresponding to RRD coupled with retinal surgery for any resident of Tuscany during 1997–2009. After elimination of ...

  17. The Northern States Power Company welding manual advisor

    International Nuclear Information System (INIS)

    Lu, Yi; Wood, R.M.

    1993-01-01

    The Welding Manual Advisor (WMA) is an object oriented expert system designed to assist Northern States Power (NSP) personnel in implementing the company's Welding Manual. The expert system captures the knowledge of welding experts, addresses important issues in welding activities and automates the use of the Welding Manual. It is estimated that use of the WMA will save $81,000 over the next six years at NSP, because of the reduction of labor and errors in the use of the Welding Manual, and facilitation of training of NSP personnel. The important features of the WMA include the accuracy and consistency in determining welding procedure and requirements, update capability, user friendly interface, on-line help function, back-up capability, and well-documented manuals

  18. MSCT follow-up in malignant lymphoma. Comparison of manual linear measurements with semi-automated lymph node analysis for therapy response classification

    International Nuclear Information System (INIS)

    Wessling, J.; Puesken, M.; Kohlhase, N.; Persigehl, T.; Mesters, R.; Heindel, W.; Buerke, B.; Koch, R.

    2012-01-01

    Purpose: Assignment of semi-automated lymph node analysis compared to manual measurements for therapy response classification of malignant lymphoma in MSCT. Materials and Methods: MSCT scans of 63 malignant lymphoma patients before and after 2 cycles of chemotherapy (307 target lymph nodes) were evaluated. The long axis diameter (LAD), short axis diameter (SAD) and bi-dimensional WHO were determined manually and semi-automatically. The time for manual and semi-automatic segmentation was evaluated. The ref. standard response was defined as the mean relative change across all manual and semi-automatic measurements (mean manual/semi-automatic LAD, SAD, semi-automatic volume). Statistical analysis encompassed t-test and McNemar's test for clustered data. Results: Response classification per lymph node revealed semi-automated volumetry and bi-dimensional WHO to be significantly more accurate than manual linear metric measurements. Response classification per patient based on RECIST revealed more patients to be correctly classified by semi-automatic measurements, e.g. 96.0 %/92.9 % (WHO bi-dimensional/volume) compared to 85.7/84.1 % for manual LAD and SAD, respectively (mean reduction in misclassified patients of 9.95 %). Considering the use of correction tools, the time expenditure for lymph node segmentation (29.7 ± 17.4 sec) was the same as with the manual approach (29.1 ± 14.5 sec). Conclusion: Semi-automatically derived 'lymph node volume' and 'bi-dimensional WHO' significantly reduce the number of misclassified patients in the CT follow-up of malignant lymphoma by at least 10 %. However, lymph node volumetry does not outperform bi-dimensional WHO. (orig.)

  19. MSCT follow-up in malignant lymphoma. Comparison of manual linear measurements with semi-automated lymph node analysis for therapy response classification

    Energy Technology Data Exchange (ETDEWEB)

    Wessling, J.; Puesken, M.; Kohlhase, N.; Persigehl, T.; Mesters, R.; Heindel, W.; Buerke, B. [Muenster Univ. (Germany). Dept. of Clinical Radiology; Koch, R. [Muenster Univ. (Germany). Inst. of Biostatistics and Clinical Research

    2012-09-15

    Purpose: Assignment of semi-automated lymph node analysis compared to manual measurements for therapy response classification of malignant lymphoma in MSCT. Materials and Methods: MSCT scans of 63 malignant lymphoma patients before and after 2 cycles of chemotherapy (307 target lymph nodes) were evaluated. The long axis diameter (LAD), short axis diameter (SAD) and bi-dimensional WHO were determined manually and semi-automatically. The time for manual and semi-automatic segmentation was evaluated. The ref. standard response was defined as the mean relative change across all manual and semi-automatic measurements (mean manual/semi-automatic LAD, SAD, semi-automatic volume). Statistical analysis encompassed t-test and McNemar's test for clustered data. Results: Response classification per lymph node revealed semi-automated volumetry and bi-dimensional WHO to be significantly more accurate than manual linear metric measurements. Response classification per patient based on RECIST revealed more patients to be correctly classified by semi-automatic measurements, e.g. 96.0 %/92.9 % (WHO bi-dimensional/volume) compared to 85.7/84.1 % for manual LAD and SAD, respectively (mean reduction in misclassified patients of 9.95 %). Considering the use of correction tools, the time expenditure for lymph node segmentation (29.7 {+-} 17.4 sec) was the same as with the manual approach (29.1 {+-} 14.5 sec). Conclusion: Semi-automatically derived 'lymph node volume' and 'bi-dimensional WHO' significantly reduce the number of misclassified patients in the CT follow-up of malignant lymphoma by at least 10 %. However, lymph node volumetry does not outperform bi-dimensional WHO. (orig.)

  20. Efficacy of manual versus free-weight training to improve maximal strength and performance for microgravity conditions.

    Science.gov (United States)

    Behringer, Michael; Schüren, Thomas; McCourt, Molly; Mester, Joachim

    2016-01-01

    We tested a simple and compact device designed for manual resistance training in conditions of microgravity (Self-Powered Rope Trainer Duo (SPoRT Duo)) to increase muscle performance. Twenty-four participants (20.8 ± 2.1 years) were randomly assigned to a manual resistance group (n = 12) and a free-weight group (n = 12). Participants performed eight exercises (three sets; 8-12 efforts) either with free weights or the SPoRT Duo twice a week for 6 weeks. Maximal isometric force of trunk flexion, back extension and chest press increased (P at least 0.01, d at least 0.52) both in the manual resistance group (18.4% ± 15.0%; 32.7% ± 22.7%; 15.3% ± 9.7%) and free-weight group (18.0% ± 13.9%; 26.6% ± 28.9%; 13.3% ± 7.6%). The change in maximal isometric force of wide grip row in both groups (d at best 0.38) did not reach statistical significance (P at best 0.08). The squat one-repetition-maximum increased in the manual resistance group (29.8% ± 22.1%) and the free-weight group (32.4% ± 26.6%). Jump height, determined by a jump-and-reach test, increased in the free-weight group (9.8% ± 13.2%) but not in the manual resistance group (2.0% ± 8.5%). Manual resistance training was equally effective in increasing strength as traditional resistance training with free weights. This apparatus is a useful addition to current in-flight exercise systems.

  1. Missouri DECA: 2010-2011 Policy Manual

    Science.gov (United States)

    Missouri Department of Elementary and Secondary Education, 2011

    2011-01-01

    This paper presents the Missouri DECA Policy Manual. This manual contains the following sections: (1) DECA Board of Directors; (2) State Sales Projects; (3) State Officers; (4) Districts; (5) Competitive Events; (6) General Conference Information; (7) Fall Leadership & State Officer Election Conference; (8) Central Region Leadership…

  2. NDS EXFOR manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1985-08-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. The IAEA Nuclear Data Section uses the EXFOR system not only for the center-to-center data exchange but also as its data storage and retrieval system. This NDS EXFOR MANUAL therefore contains the agreed EXFOR coding rules and format, supplemented by NDS internal compilation rules. The EXFOR system and the EXFOR nuclear data library with several million data records originate from the cooperation of an increasing number of data centers whose names and addresses can be found inside the Manual. Their contributions and cooperative efforts are gratefully acknowledged. (author)

  3. NDS EXFOR manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1996-01-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. The IAEA Nuclear Data Section uses the EXFOR system not only for the center-to-center data exchange but also as its data storage and retrieval system. This NDS EXFOR MANUAL therefore contains the agreed EXFOR coding rules and format, supplemented by NDS internal compilation rules. The EXFOR system and the EXFOR nuclear data library with several million data records originate from the cooperation of an increasing number of data centers whose names and addresses can be found inside the Manual. Their contributions and cooperative efforts are gratefully acknowledged. (author)

  4. Post-operative analgesia following total knee arthroplasty: comparison of low-dose intrathecal morphine and single-shot ultrasound-guided femoral nerve block: a randomized, single blinded, controlled study.

    Science.gov (United States)

    Frassanito, L; Vergari, A; Zanghi, F; Messina, A; Bitondo, M; Antonelli, M

    2010-07-01

    Total knee arthroplasty often results in marked postoperative pain. A recent meta-analysis supports the use of femoral nerve block or alternatively spinal injection of morphine plus local anaesthetic for post-operative analgesia. On the other hand, the use of intrathecal morphine may be associated with a large number of distressing side effects (itching, urinary retention, nausea and vomiting, delayed respiratory depression). The aim of this study was to compare the effectiveness of femoral nerve block and low dose intrathecal morphine in post-operative analgesia after primary unilateral total knee arthroplasty. Fifty-two consecutive patients scheduled for primary unilateral total knee arthroplasty were allocated to the intrathecal morphine group (ITM group) or to the femoral nerve block group (FNB group). In ITM group a subarachnoid puncture was performed at the L3-L4 inter-vertebral space with hyperbaric bupivacaine 15 mg plus 100 mcg of preservative-free morphine. Patients allocated to the FNB group received a single-injection ultrasound-assisted femoral nerve block with ropivacaine 0.75% 25 ml before the spinal injection of hyperbaric bupivacaine 15 mg. All patients received postoperative patient-controlled-analgesia (PCA) morphine, using a 1-mg bolus and a 5-minute lockout period. Data were analyzed using Student t test or two-way analysis of variance (ANOVA) for repeated measures with time and treatment as the 2 factors. Post hoc comparisons were performed by Bonferroni test. Statistical significance for all test was a p value < 0.05. Patient characteristics were similar between the 2 groups. We found a statistically significant differences in postoperative pain between the two groups: ITM group had the lower visual analogic pain score (VAS) values. Morphine consumption was lower in the ITM group: average consumption within the first 6 hours was 0.9 mg in IT group compared to 3.1 mg in FNB group; at 12 h 4.2 mg vs 6.3 mg; at 24 h 6.9 mg vs 10.3 mg; at 48 h 9

  5. User's manual for remote-handled transuranic waste container welding and inspection fixture

    International Nuclear Information System (INIS)

    Hauptmann, J.P.

    1985-09-01

    Rockwell Hanford Operations (Rockwell) has designed built, and tested a prototype remotely operated welding and inspection fixture to be used in making the closure weld on the remote-handled transuranic (RH-TRU) waste container. The RH-TRU waste container has an average TRU concentration in excess of 100 nCi/gm, and a surface radiation dose rate in excess of 200 mrem/h, but not exceeding 100 rem/h. The RH-TRU waste container is to be used by defense waste generator sites in the United States for final packaging of RH-TRU wastes and is compatible with the requirements of the Waste Isolation Pilot Plant (WIPP) and the WIPP handling system. Standard and stacked RH-TRU container designs are available. The standard container is 26 in. in dia. by 121 in. high; the stacked containers are 26 in. in dia. by 61.25 in. high. After loading, two stacked containers are fitted and welded together to form the identical measurements of the standard 121-in. container. The prototype RH-TRU waste container welding and inspection fixture was intended for test and evaluation only, and not for installation in an operating facility. The final RH-TRU waste container welding and inspection fixture drawings (see appendix) incorporate several changes made following operational testing of the original fixture. These modifications are identified in this manual. However, not all modifications have been functionally tested. The purpose of this manual is to aid waste generator sites in designing a remotely operated welding and inspection fixture that will conform to their own requirements. Modifications to the Rockwell design must be evaluated for structural and WIPP handling requirements. This manual also provides design philosophy, component vendor information, and cost estimates

  6. Effect of students’ determination of testing time on their test performance

    NARCIS (Netherlands)

    Bakker, D.R.; Deng, D.M.; Wesselink, P.R.; Vervoorn, J.M.

    2017-01-01

    This article investigates whether giving students control over preparing for and the moment of taking a test affects their test results in comparison with when the school is in control of the amount of training followed by a predetermined test moment. The students participated in training for manual

  7. 21 CFR 866.2180 - Manual colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter. (a) Identification. A manual colony counter is a device intended for medical purposes that consists...

  8. The comparison of manual and LabVIEW-based fuzzy control on mechanical ventilation.

    Science.gov (United States)

    Guler, Hasan; Ata, Fikret

    2014-09-01

    The aim of this article is to develop a knowledge-based therapy for management of rats with respiratory distress. A mechanical ventilator was designed to achieve this aim. The designed ventilator is called an intelligent mechanical ventilator since fuzzy logic was used to control the pneumatic equipment according to the rat's status. LabVIEW software was used to control all equipments in the ventilator prototype and to monitor respiratory variables in the experiment. The designed ventilator can be controlled both manually and by fuzzy logic. Eight female Wistar-Albino rats were used to test the designed ventilator and to show the effectiveness of fuzzy control over manual control on pressure control ventilation mode. The anesthetized rats were first ventilated for 20 min manually. After that time, they were ventilated for 20 min by fuzzy logic. Student's t-test for p < 0.05 was applied to the measured minimum, maximum and mean peak inspiration pressures to analyze the obtained results. The results show that there is no statistical difference in the rat's lung parameters before and after the experiments. It can be said that the designed ventilator and developed knowledge-based therapy support artificial respiration of living things successfully. © IMechE 2014.

  9. State Energy Program Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Office of Building Technology, State and Community Programs

    1999-03-17

    The State Energy Program Operations Manual is a reference tool for the states and the program officials at the U.S. Department of Energy's Office of Building Technology, State and Community Programs and Regional Support Offices as well as State Energy Offices. The Manual contains information needed to apply for and administer the State Energy Program, including program history, application rules and requirements, and program administration and monitoring requirements.

  10. Manual for a Volunteer Services System.

    Science.gov (United States)

    Helgerson, Linda; And Others

    This manual presents guidelines for planning, monitoring, and controlling the development and operation of volunteer assistance programs. The materials included address questions related to both the process of establishing a volunteer program and the administration of a volunteer management system. The manual is not intended to provide a blueprint…

  11. Host Families Matter: The Homestay Manual.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This manual provides guidelines, sample documents, and sample lesson plans for the trainers, trainees, and host families involved in homestays for Peace Corps volunteers. The manual contains 11 sections that deal with the following topics: (1) introduction; (2) policy, timelines, and responsibilities; (3) medical and financial issues; (4) host…

  12. 21 CFR 886.1770 - Manual refractor.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1770 Manual refractor. (a) Identification. A manual refractor is a device that is a set of lenses of varous dioptric powers intended to measure the refractive error of the eye. (b) Classification. Class I (general controls). The device is exempt from the...

  13. 21 CFR 890.5180 - Manual patient rotation bed.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5180 Manual patient rotation bed. (a) Identification. A manual patient rotation bed is a device that turns a patient who is... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual patient rotation bed. 890.5180 Section 890...

  14. TV Trouble-Shooting Manual. Volumes 7-8. Part 3: Synchronisation and Deflection Circuits. Student and Instructor's Manuals.

    Science.gov (United States)

    Mukai, Masaaki; Kobayashi, Ryozo

    These volumes are, respectively, the self-instructional student manual and the teacher manual that cover the third set of training topics in this course for television repair technicians. Both contain identical information on synchronization and deflection circuits, including sections on the principle of synchronized deflection, synchronization…

  15. Unraveling the Mechanisms of Manual Therapy: Modeling an Approach.

    Science.gov (United States)

    Bialosky, Joel E; Beneciuk, Jason M; Bishop, Mark D; Coronado, Rogelio A; Penza, Charles W; Simon, Corey B; George, Steven Z

    2018-01-01

    Synopsis Manual therapy interventions are popular among individual health care providers and their patients; however, systematic reviews do not strongly support their effectiveness. Small treatment effect sizes of manual therapy interventions may result from a "one-size-fits-all" approach to treatment. Mechanistic-based treatment approaches to manual therapy offer an intriguing alternative for identifying patients likely to respond to manual therapy. However, the current lack of knowledge of the mechanisms through which manual therapy interventions inhibit pain limits such an approach. The nature of manual therapy interventions further confounds such an approach, as the related mechanisms are likely a complex interaction of factors related to the patient, the provider, and the environment in which the intervention occurs. Therefore, a model to guide both study design and the interpretation of findings is necessary. We have previously proposed a model suggesting that the mechanical force from a manual therapy intervention results in systemic neurophysiological responses leading to pain inhibition. In this clinical commentary, we provide a narrative appraisal of the model and recommendations to advance the study of manual therapy mechanisms. J Orthop Sports Phys Ther 2018;48(1):8-18. doi:10.2519/jospt.2018.7476.

  16. AKURASI HITUNG JUMLAH ERITROSIT METODE MANUAL DAN METODE OTOMATIS

    Directory of Open Access Journals (Sweden)

    Neni Oktiyani

    2017-12-01

    Full Text Available Hitung jumlah eritrosit dilakukan dengan menggunakan metode manual dan metode otomatis. Metode manual menggunakan alat Hemositometer dapat memberikan hasil yang dipercaya dan akurat tergantung keahlian dari teknisi laboratorium. Metode otomatis memberikan hasil yang lebih mudah, cepat dan teliti dibandingkan dengan cara manual. Tujuan penelitian untuk membandingkan akurasi hitung jumlah eritrosit metode manual dan metode otomatis. Jenis penelitian yang digunakan adalah survey analitik dengan rancangan cross sectional. Penelitian ini membandingkan data hasil hitung jumlah eritrosit antara metode manual dengan metode otomatis dengan menggunakan 3 jenis darah kontrol hitung jumlah eritrosit high, normal, dan low dengan 9 kali pengulangan. Hasil penelitian menunjukkan nilai rerata hitung jumlah eritrosit darah kontrol high metode manual sebesar 7,08 juta/µl dengan nilai bias 1,4% dan metode otomatis sebesar 7,03 juta/µl dengan nilai bias 0,7%. Rerata hitung jumlah eritrosit darah kontrol normal metode manual sebesar 4,50 juta/µl dengan nilai bias 0,9% dan metode otomatis sebesar 4,43 juta/µl dengan nilai bias 2,4%. Rerata hitung jumlah eritrosit darah kontrol low metode manual sebesar 1,72 juta/µl dengan nilai bias 4,4% dan metode otomatis sebesar 1,67 juta/µl dengan nilai bias 1,2%. Uji statistik menunjukkan tidak ada perbedaan akurasi yang bermakna antara hitung jumlah eritrosit metode manual dengan metode otomatis.

  17. Sodium safety manual

    International Nuclear Information System (INIS)

    Hayes, D.J.; Gardiner, R.L.

    1980-09-01

    The sodium safety manual is based upon more than a decade of experience with liquid sodium at Berkeley Nuclear Laboratories (BNL). It draws particularly from the expertise and experience developed in the course of research work into sodium fires and sodium water reactions. It draws also on information obtained from the UKAEA and other sodium users. Many of the broad principles will apply to other Establishments but much of the detail is specific to BNL and as a consequence its application at other sites may well be limited. Accidents with sodium are at best unpleasant and at worst lethal in an extremely painful way. The object of this manual is to help prevent sodium accidents. It is not intended to give detailed advice on specific precautions for particular situations, but rather to set out the overall strategy which will ensure that sodium activities will be pursued safely. More detail is generally conveyed to staff by the use of local instructions known as Sodium Working Procedures (SWP's) which are not reproduced in this manual although a list of current SWP's is included. Much attention is properly given to the safe design and operation of larger facilities; nevertheless evidence suggests that sodium accidents most frequently occur in small-scale work particularly in operations associated with sodium cleaning and special care is needed in all such cases. (U.K.)

  18. Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    Science.gov (United States)

    Tsuboyama, Takahiro; Jost, Gregor; Pietsch, Hubertus; Tomiyama, Noriyuki

    2017-09-01

    The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-tracking technique, and thoracic-abdominal time-resolved 4-dimensional [4D] MRA) were performed after power and manual injection of gadobutrol (0.1 mmol/kg) at 2 mL/s in 12 pigs (6 sets of power and manual injections for each type of CE-MRA). For the quantitative analysis, the signal-to-noise ratio was measured on ascending aorta, descending aorta, brachiocephalic trunk, common carotid artery, and external carotid artery on the 6 sets of head-neck 3D MRA, and on ascending aorta, descending aorta, brachiocephalic trunk, abdominal aorta, celiac trunk, and renal artery on the 6 sets of thoracic-abdominal 3D MRA. Bolus shapes were evaluated on the 6 sets each of test-bolus scans and 4D MRA. For the qualitative analysis, arterial enhancement, superimposition of nontargeted enhancement, and overall image quality were evaluated on 3D MRA. Visibility of bolus transition was assessed on 4D MRA. Intraindividual comparison between power and manual injection was made by paired t test, Wilcoxon rank sum test, and analysis of variance by ranks. Signal-to-noise ratio on 3D MRA was statistically higher with power injection than with manual injection (P < 0.001). Bolus shapes (test-bolus, 4D MRA) were represented by a characteristic standard bolus curve (sharp first-pass peak followed by a gentle recirculation peak) in all the 12 scans with power injection, but only in 1 of the 12 scans with manual injection. Standard deviations of time-to-peak enhancement were smaller in power injection than in manual injection. Qualitatively, although both injection methods achieved diagnostic quality on 3D MRA, power injection exhibited significantly higher image quality than manual injection (P = 0.001) due to

  19. Sierra Structural Dynamics Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Garth M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-19

    Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD , we refer the reader to Sierra/SD, User's Notes . Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature. This page intentionally left blank.

  20. Laboratory Waste Disposal Manual. Revised Edition.

    Science.gov (United States)

    Stephenson, F. G., Ed.

    This manual is designed to provide laboratory personnel with information about chemical hazards and ways of disposing of chemical wastes with minimum contamination of the environment. The manual contains a reference chart section which has alphabetical listings of some 1200 chemical substances with information on the health, fire and reactivity…

  1. Manual for Training Leprosy Rehabilitation Workers.

    Science.gov (United States)

    Itoh, Masayoshi; Eason, Alice L.

    The purpose of this manual is to introduce the general concepts and techniques in leprosy rehabilitation to physical therapy aides. Because of the lack of well-trained, qualified, physical therapists, the committee on leprosy rehabilitation considers it necessary to publish a teaching manual outlining leprosy rehabilitation for those who work with…

  2. Gingival abrasion and recession in manual and oscillating-rotating power brush users.

    Science.gov (United States)

    Rosema, N A M; Adam, R; Grender, J M; Van der Sluijs, E; Supranoto, S C; Van der Weijden, G A

    2014-11-01

    To assess gingival recession (GR) in manual and power toothbrush users and evaluate the relationship between GR and gingival abrasion scores (GA). This was an observational (cross-sectional), single-centre, examiner-blind study involving a single-brushing exercise, with 181 young adult participants: 90 manual brush users and 91 oscillating-rotating power brush users. Participants were assessed for GR and GA as primary response variables. Secondary response variables were the level of gingival inflammation, plaque score reduction and brushing duration. Pearson correlation was used to describe the relationship between number of recession sites and number of abrasions. Prebrushing (baseline) and post-brushing GA and plaque scores were assessed and differences analysed using paired tests. Two-sample t-test was used to analyse group differences; ancova was used for analyses of post-brushing changes with baseline as covariate. Overall, 97.8% of the study population had at least one site of ≥1 mm of gingival recession. For the manual group, this percentage was 98.9%, and for the power group, this percentage was 96.7% (P = 0.621). Post-brushing, the power group showed a significantly smaller GA increase than the manual group (P = 0.004); however, there was no significant correlation between number of recession sites and number of abrasions for either group (P ≥ 0.327). Little gingival recession was observed in either toothbrush user group; the observed GR levels were comparable. Lower post-brushing gingival abrasion levels were seen in the power group. There was no correlation between gingival abrasion as a result of brushing and the observed gingival recession following use of either toothbrush. © 2014 The Authors International Journal of Dental Hygiene Published by John Wiley & Sons Ltd.

  3. Beyond the Manual Channel

    DEFF Research Database (Denmark)

    , the main focus there is on spoken languages in their written and spoken forms. This series of workshops, however, offers a forum for researchers focussing on sign languages. For the fourth time, the workshop had sign language corpora as its main topic. This time, the focus was on any aspect beyond...... the manual channel. Not surprisingly, most papers deal with non-manuals on the face. Once again, the papers at this workshop clearly identify the potentials of even closer cooperation between sign linguists and sign language engineers, and we think it is events like this that contribute a lot to a better...

  4. RELAP-7 Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Berry, Ray Alden [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Peterson, John William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, Richard Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kadioglu, Samet Yucel [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This document summarizes the physical models and mathematical formulations used in the RELAP-7 code. In summary, the MOOSE based RELAP-7 code development is an ongoing effort. The MOOSE framework enables rapid development of the RELAP-7 code. The developmental efforts and results demonstrate that the RELAP-7 project is on a path to success. This theory manual documents the main features implemented into the RELAP-7 code. Because the code is an ongoing development effort, this RELAP-7 Theory Manual will evolve with periodic updates to keep it current with the state of the development, implementation, and model additions/revisions.

  5. Urinalysis: The Automated Versus Manual Techniques; Is It Time To Change?.

    Science.gov (United States)

    Ahmed, Asmaa Ismail; Baz, Heba; Lotfy, Sarah

    2016-01-01

    Urinalysis is the third major test in clinical laboratory. Manual technique imprecision urges the need for a rapid reliable automated test. We evaluated the H800-FUSIOO automatic urine sediment analyzer and compared it to the manual urinalysis technique to determine if it may be a competitive substitute in laboratories of central hospitals. 1000 urine samples were examined by the two methods in parallel. Agreement, precision, carryover, drift, sensitivity, specificity, and practicability criteria were tested. Agreement ranged from excellent to good for all urine semi-quantitative components (K > 0.4, p = 0.000), except for granular casts (K = 0.317, p = 0.000). Specific gravity results correlated well between the two methods (r = 0.884, p = 0.000). RBCS and WBCs showed moderate correlation (r = 0.42, p = 0.000) and (r = 0.44, p = 0.000), respectively. The auto-analyzer's within-run precision was > 75% for all semi-quantitative components except for proteins (50% precision). This finding in addition to the granular casts poor agreement indicate the necessity of operator interference at the critical cutoff values. As regards quantitative contents, RBCs showed a mean of 69.8 +/- 3.95, C.V. = 5.7, WBCs showed a mean of 38.9 +/- 1.9, C.V. = 4.9). Specific gravity, pH, microalbumin, and creatinine also showed good precision results with C.Vs of 0.000, 2.6, 9.1, and 0.00 respectively. In the between run precision, positive control showed good precision (C.V. = 2.9), while negative control's C.V. was strikingly high (C.V. = 127). Carryover and drift studies were satisfactory. Manual examination of inter-observer results showed major discrepancies (urinalysis decreases observer-associated variation and offers prompt competitive results when standardized for screening away from the borderline cutoffs.

  6. User's Manual for RESRAD-OFFSITE Version 2.

    Energy Technology Data Exchange (ETDEWEB)

    Yu, C.; Gnanapragasam, E.; Biwer, B. M.; Kamboj, S.; Cheng, J. -J.; Klett, T.; LePoire, D.; Zielen, A. J.; Chen, S. Y.; Williams, W. A.; Wallo, A.; Domotor, S.; Mo, T.; Schwartzman, A.; Environmental Science Division; DOE; NRC

    2007-09-05

    The RESRAD-OFFSITE code is an extension of the RESRAD (onsite) code, which has been widely used for calculating doses and risks from exposure to radioactively contaminated soils. The development of RESRAD-OFFSITE started more than 10 years ago, but new models and methodologies have been developed, tested, and incorporated since then. Some of the new models have been benchmarked against other independently developed (international) models. The databases used have also expanded to include all the radionuclides (more than 830) contained in the International Commission on Radiological Protection (ICRP) 38 database. This manual provides detailed information on the design and application of the RESRAD-OFFSITE code. It describes in detail the new models used in the code, such as the three-dimensional dispersion groundwater flow and radionuclide transport model, the Gaussian plume model for atmospheric dispersion, and the deposition model used to estimate the accumulation of radionuclides in offsite locations and in foods. Potential exposure pathways and exposure scenarios that can be modeled by the RESRAD-OFFSITE code are also discussed. A user's guide is included in Appendix A of this manual. The default parameter values and parameter distributions are presented in Appendix B, along with a discussion on the statistical distributions for probabilistic analysis. A detailed discussion on how to reduce run time, especially when conducting probabilistic (uncertainty) analysis, is presented in Appendix C of this manual.

  7. Microbial ecology laboratory procedures manual NASA/MSFC

    Science.gov (United States)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  8. Comparative Study between Sequential Automatic and Manual Home Respiratory Polygraphy Scoring Using a Three-Channel Device: Impact of the Manual Editing of Events to Identify Severe Obstructive Sleep Apnea

    Directory of Open Access Journals (Sweden)

    Glenda Ernst

    2015-01-01

    Full Text Available Objective. According to current guidelines, autoscoring of respiratory events in respiratory polygraphy requires manual scoring. The aim of this study was to evaluate the agreement between automatic analysis and manual scoring to identify patients with suspected OSA. Methods. This retrospective study analyzed 791 records from respiratory polygraphy (RP performed at home. The association grade between automatic scoring and manual scoring was evaluated using Kappa coefficient and the agreement using Bland and Altman test and intraclass correlation coefficient (CCI. To determine the accuracy in the identification of AHI≥30 eV/h, the ROC curve analysis was used. Results. The population analyzed consisted of 493 male (62.3% and 298 female patients, with an average age of 54.7±14.20 years and BMI of 32.7±8.21 kg/m2. There was no significant difference between automatic and manual apnea/hypopnea indexes (aAHI, mAHI: aAHI 17.25 (SD: 17.42 versus mAHI 21.20±7.96 (p; NS. The agreement between mAHI and aAHI to AHI≥30 was 94%, with a Kappa coefficient of 0.83 (p<0.001 and a CCI of 0.83. The AUC-ROC, sensitivity, and specificity were 0.99 (CI 95%: 0.98-0.99, p<0.001, 86% (CI 95%: 78.7–91.4, and 97% (CI 95%: 96–98.3, respectively. Conclusions. We observed good agreement between automatic scoring and sequential manual scoring to identify subjects with AHI≥30 eV/h.

  9. Manual control of unstable systems

    Science.gov (United States)

    Allen, R. W.; Hogue, J. R.; Parseghian, Z.

    1986-01-01

    Under certain operational regimes and failure modes, air and ground vehicles can present the human operator with a dynamically unstable or divergent control task. Research conducted over the last two decades has explored the ability of the human operator to control unstable systems under a variety of circumstances. Past research is reviewed and human operator control capabilities are summarized. A current example of automobile directional control under rear brake lockup conditions is also reviewed. A control system model analysis of the driver's steering control task is summarized, based on a generic driver/vehicle model presented at last year's Annual Manual. Results from closed course braking tests are presented that confirm the difficulty the average driver has in controlling the unstable directional dynamics arising from rear wheel lockup.

  10. Matematica 2. Manual do Professor (Mathematics 2. Teacher's Manual).

    Science.gov (United States)

    D'Alu, Maria Jose Miranda de Sousa

    This teacher's manual accompanies a mathematics textbook for second graders, written in Portuguese. Developed from objectives set forth by the National Portuguese Materials Development Center, it follows closely the objectives and methodology of major curricula used in schools of the United States. Consideration was given to the Portuguese child's…

  11. A user's manual for managing database system of tensile property

    International Nuclear Information System (INIS)

    Ryu, Woo Seok; Park, S. J.; Kim, D. H.; Jun, I.

    2003-06-01

    This manual is written for the management and maintenance of the tensile database system for managing the tensile property test data. The data base constructed the data produced from tensile property test can increase the application of test results. Also, we can get easily the basic data from database when we prepare the new experiment and can produce better result by compare the previous data. To develop the database we must analyze and design carefully application and after that, we can offer the best quality to customers various requirements. The tensile database system was developed by internet method using Java, PL/SQL, JSP(Java Server Pages) tool

  12. Math/Measurement Literacy for Upgrading Skills of Industrial Hourly Workers. Math Manual.

    Science.gov (United States)

    McMahon, Joan L.

    This manual contains materials for a numeracy course for adult industrial workers. In addition to assessment tests, seven units are provided. Unit topics are whole numbers; fractions; decimals; percents, median, and range; measurement and signed numbers; ratio/proportion and introduction to algebra; and computer literacy using algebra software.…

  13. Study of developing nuclear fabrication facility's integrated emergency response manual

    International Nuclear Information System (INIS)

    Kim, Taeh Yeong; Cho, Nam Chan; Han, Seung Hoon; Moon, Jong Han; Lee, Jin Hang; Min, Guem Young; Han, Ji Ah

    2016-01-01

    Public begin to pay attention to emergency management. Thus, public's consensus on having high level of emergency management system up to advanced country's is reached. In this social atmosphere, manual is considered as key factor to prevent accident or secure business continuity. Therefore, we first define possible crisis at KEPCO Nuclear Fuel (hereinafter KNF) and also make a 'Reaction List' for each crisis situation at the view of information-design. To achieve it, we analyze several country's crisis response manual and then derive component, indicate duties and roles at the information-design point of view. From this, we suggested guideline to make 'Integrated emergency response manual(IERM)'. The manual we used before have following few problems; difficult to applicate at the site, difficult to deliver information. To complement these problems, we searched manual elements from the view of information-design. As a result, we develop administrative manual. Although, this manual could be thought as fragmentary manual because it confined specific several agency/organization and disaster type

  14. Hanford Waste Vitrification Plant technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Larson, D.E. [ed.; Watrous, R.A.; Kruger, O.L. [and others

    1996-03-01

    A key element of the Hanford waste management strategy is the construction of a new facility, the Hanford Waste Vitrification Plant (HWVP), to vitrify existing and future liquid high-level waste produced by defense activities at the Hanford Site. The HWVP mission is to vitrify pretreated waste in borosilicate glass, cast the glass into stainless steel canisters, and store the canisters at the Hanford Site until they are shipped to a federal geological repository. The HWVP Technical Manual (Manual) documents the technical bases of the current HWVP process and provides a physical description of the related equipment and the plant. The immediate purpose of the document is to provide the technical bases for preparation of project baseline documents that will be used to direct the Title 1 and Title 2 design by the A/E, Fluor. The content of the Manual is organized in the following manner. Chapter 1.0 contains the background and context within which the HWVP was designed. Chapter 2.0 describes the site, plant, equipment and supporting services and provides the context for application of the process information in the Manual. Chapter 3.0 provides plant feed and product requirements, which are primary process bases for plant operation. Chapter 4.0 summarizes the technology for each plant process. Chapter 5.0 describes the engineering principles for designing major types of HWVP equipment. Chapter 6.0 describes the general safety aspects of the plant and process to assist in safe and prudent facility operation. Chapter 7.0 includes a description of the waste form qualification program and data. Chapter 8.0 indicates the current status of quality assurance requirements for the Manual. The Appendices provide data that are too extensive to be placed in the main text, such as extensive tables and sets of figures. The Manual is a revision of the 1987 version.

  15. Hanford Waste Vitrification Plant technical manual

    International Nuclear Information System (INIS)

    Larson, D.E.; Watrous, R.A.; Kruger, O.L.

    1996-03-01

    A key element of the Hanford waste management strategy is the construction of a new facility, the Hanford Waste Vitrification Plant (HWVP), to vitrify existing and future liquid high-level waste produced by defense activities at the Hanford Site. The HWVP mission is to vitrify pretreated waste in borosilicate glass, cast the glass into stainless steel canisters, and store the canisters at the Hanford Site until they are shipped to a federal geological repository. The HWVP Technical Manual (Manual) documents the technical bases of the current HWVP process and provides a physical description of the related equipment and the plant. The immediate purpose of the document is to provide the technical bases for preparation of project baseline documents that will be used to direct the Title 1 and Title 2 design by the A/E, Fluor. The content of the Manual is organized in the following manner. Chapter 1.0 contains the background and context within which the HWVP was designed. Chapter 2.0 describes the site, plant, equipment and supporting services and provides the context for application of the process information in the Manual. Chapter 3.0 provides plant feed and product requirements, which are primary process bases for plant operation. Chapter 4.0 summarizes the technology for each plant process. Chapter 5.0 describes the engineering principles for designing major types of HWVP equipment. Chapter 6.0 describes the general safety aspects of the plant and process to assist in safe and prudent facility operation. Chapter 7.0 includes a description of the waste form qualification program and data. Chapter 8.0 indicates the current status of quality assurance requirements for the Manual. The Appendices provide data that are too extensive to be placed in the main text, such as extensive tables and sets of figures. The Manual is a revision of the 1987 version

  16. Oregon School Bond Manual. Fourth Edition.

    Science.gov (United States)

    Oregon State Dept. of Education, Salem.

    The manual is intended to guide attorneys and officials of school districts in the issuance and sale of school district bonds. Purchasers of school district bonds rely on the recommendations of accredited bond attorneys who render opinions concerning the validity and legality of bond issues offered for sale. This manual is designed to assist in…

  17. Manual therapy is an effective treatment for frozen shoulder in diabetics: an observational study.

    Science.gov (United States)

    Düzgün, Irem; Baltaci, Gül; Atay, Ozgür Ahmet

    2012-01-01

    This study aims to compare the efficacy of manual therapy in the frozen shoulder patients with or without diabetes mellitus. Between May 2006 and January 2008, 50 patients (10 males, 40 females; mean age 52 ± 10 years; range 40 to 65 years) orthopedic surgeons referred to the Sports Physiotherapy Unit were included in the study. The patients were divided into two groups, including patients with primary frozen shoulder with type II diabetes mellitus (n=12) and non diabetics (n=38). All patients underwent a rehabilitation program including cold application, manual therapy and exercises twice a week. A total of 16 treatment sessions were performed. The most important part of the manual therapy included scapular mobilization and posterior capsule stretching. The range of motion was measured by goniometry. Functional activity status was assessed by Constant's score. The pain level was evaluated by visual analog scale, while muscle strength was evaluated by hand-held dynamometer. Student t-test was used to compare between the parameters of groups, while Paired sample t-test was used to compare pre- and post-treatment parameters of the patients. The range of motion, functional activity status and muscular strength were improved and the pain level was reduced after rehabilitation in all of the patients in both groups (p0.05). There were no differences in range of motion, functional activity status, pain level, and muscle strength before and after rehabilitation between the groups (p>0.05). Manual therapy approaches may be safely applied in diabetic patients with frozen shoulder.

  18. The development of practice manual for LSC based on job analysis in radiation measurement and analysis

    International Nuclear Information System (INIS)

    Shin, W H; Park, T J

    2017-01-01

    Radiation technology is closely related to the industrial growth and the creation of employment in Korea. The techniques as radiation or/and radioactivity measurement, and the practical skills achieving a higher level analysis are required. In this study, practice manual for liquid scintillation counter were developed by job analysis. Raw data applied in job analysis are collected by on/off line survey by 420 workers employed in KOREA. Importance-priority analysis was performed to make duties and competency unit that consists of knowledge, skills as each task. Refined data was reviewed by expert who experienced actual duties on site. Classification was conducted by focus group interview to deduct duties and competency unit. From the radiation devices in measurement and analysis, liquid scintillation counter was preferentially selected because of the high demands for training. Investigation of build-up status to liquid scintillation counter in KOREA was conducted. Then technical specification and operating procedure of 2 main devices were analyzed and integrated by practice manual. Duties and competency unit were applied to integrated materials respectively. To validate effectiveness, test curriculum was designed by the advanced course to workers who engaged in radiation measurement and analysis. The developed manual is structured to take advantage of test training. This manual will be a practical handbook that can improve the knowledge, skills of radiation workers in Korea. (paper)

  19. The development of practice manual for LSC based on job analysis in radiation measurement and analysis

    Science.gov (United States)

    Shin, W. H.; Park, T. J.

    2017-06-01

    Radiation technology is closely related to the industrial growth and the creation of employment in Korea. The techniques as radiation or/and radioactivity measurement, and the practical skills achieving a higher level analysis are required. In this study, practice manual for liquid scintillation counter were developed by job analysis. Raw data applied in job analysis are collected by on/off line survey by 420 workers employed in KOREA. Importance-priority analysis was performed to make duties and competency unit that consists of knowledge, skills as each task. Refined data was reviewed by expert who experienced actual duties on site. Classification was conducted by focus group interview to deduct duties and competency unit. From the radiation devices in measurement and analysis, liquid scintillation counter was preferentially selected because of the high demands for training. Investigation of build-up status to liquid scintillation counter in KOREA was conducted. Then technical specification and operating procedure of 2 main devices were analyzed and integrated by practice manual. Duties and competency unit were applied to integrated materials respectively. To validate effectiveness, test curriculum was designed by the advanced course to workers who engaged in radiation measurement and analysis. The developed manual is structured to take advantage of test training. This manual will be a practical handbook that can improve the knowledge, skills of radiation workers in Korea.

  20. Dynamic delivery of the National Transit Database Sampling Manual.

    Science.gov (United States)

    2013-02-01

    This project improves the National Transit Database (NTD) Sampling Manual and develops an Internet-based, WordPress-powered interactive Web tool to deliver the new NTD Sampling Manual dynamically. The new manual adds guidance and a tool for transit a...

  1. Proposed quality assurance manual for the Office of Waste Isolation

    International Nuclear Information System (INIS)

    1977-01-01

    The manual provides guidelines for assuring safe and reliable siting, design, procurement and construction, operation, and decommissioning of a radioactive waste repository. The organization of the program is given and the program itself is defined. The program includes the site evaluation, site selection, design, procurement, fabrication, installation, and testing of any system or component that is safety related. It also included all necessary documentation and auditing

  2. A framework for the design of a voice-activated, intelligent, and hypermedia-based aircraft maintenance manual

    Science.gov (United States)

    Patankar, Manoj Shashikant

    estimates the United States air carriers to operate 3,991 large jet aircraft in the year 1996 (FAA Aviation Forecasts, 1987-1998). With an estimate of seventy manuals per such aircraft, the development of intelligent manuals is expected to impact 279,370 manuals in this country. Soon, over 55 thousand maintenance technicians will be able to carry the seven pound system to an aircraft, use voice commands to access the aircraft's files on the system, seek assistance from the expert system to diagnose the fault, and obtain instructions on how to rectify the fault. The evolutionary design approach and the rapid prototyping techniques were very well suited for the spiral testing strategy. Therefore, this strategy was used to test the structural and functional validity of this research. Professors Darrell Anderson and Brian Stout (Aviation faculty at San Jose State University) and Mr. Gregory Shea (a United Airlines mechanic and SJSU student) are representatives of the real-world users of the final product. Therefore, they conducted the alpha test of this prototype. Mr. Daniel Neal and Mr. Stephen Harms have been actively involved in light aircraft maintenance for more than ten years. They evaluated the prototype's usability. All the above evaluators used standard testing tools and evaluated the prototype under field conditions. The evaluators concluded that the VIHAMS prototype used a valid fault diagnosis strategy, the system architecture could be used to develop similar systems using off-the-shelf tools, and the voice input system could be refined to improve its usability.

  3. Thermo-sensitive intelligent track membrane

    International Nuclear Information System (INIS)

    Pang Deling; Ren Lihua; Qian Zhilin; Huang Gang; Zhang Jinhua

    1999-01-01

    Using N-isopropylacryl-amide (NIP AAm) thermo-sensitive function material as monomer and nuclear track microporous membrane (NTMM) as baseline material, a thermo-sensitive intelligent track membrane (TsITM) has been prepared by the over-oxidization and pre-irradiation grafting techniques. The TsITM can be used to make a micro-switch controlled by temperature and to adjust particle screening and osmosis. To obtain sub-micron responsive grafted track pores only a very thin thermo-sensitive layer is needed. The TsITM pores are capable of swelling and shrinking rapidly and respond more sensitively to temperature

  4. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    Energy Technology Data Exchange (ETDEWEB)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea)

    2008-07-15

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  5. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo; Kim, Sam Soo

    2008-01-01

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  6. Rolling resistance and propulsion efficiency of manual and power-assisted wheelchairs.

    Science.gov (United States)

    Pavlidou, Efthymia; Kloosterman, Marieke G M; Buurke, Jaap H; Rietman, Johan S; Janssen, Thomas W J

    2015-11-01

    Rolling resistance is one of the main forces resisting wheelchair propulsion and thus affecting stress exerted on the upper limbs. The present study investigates the differences in rolling resistance, propulsion efficiency and energy expenditure required by the user during power-assisted and manual propulsion. Different tire pressures (50%, 75%, 100%) and two different levels of motor assistance were tested. Drag force, energy expenditure and propulsion efficiency were measured in 10 able-bodied individuals under different experimental settings on a treadmill. Results showed that drag force levels were significantly higher in the 50%, compared to the 75% and 100% inflation conditions. In terms of wheelchair type, the manual wheelchair displayed significantly lower drag force values than the power-assisted one. The use of extra-power-assisted wheelchair appeared to be significantly superior to conventional power-assisted and manual wheelchairs concerning both propulsion efficiency and energy expenditure required by the user. Overall, the results of the study suggest that the use of power-assisted wheelchair was more efficient and required less energy input by the user, depending on the motor assistance provided. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Manual lymphatic drainage and therapeutic ultrasound in liposuction and lipoabdominoplasty post-operative period

    Directory of Open Access Journals (Sweden)

    Igor F. B. Masson

    2014-01-01

    Full Text Available Background: Physiotherapy in the plastic surgery post-operative (PO is essential to provide means for an adequate and fast recovery as it restores function through the use of physiotherapeutic procedures. Aim: The aim of the following study is to verify the effects of the association between the manual lymphatic drainage and the therapeutic ultrasound on pain, oedema and the tissue fibrosis in liposuction and lipoabdominoplasty PO. Design: This is a clinical trial prospective. Materials and Methods: Eighteen women aged between 18 and 60 years participated in this study, in the late PO period following lipoabdominoplasty or liposuction in the abdomen, flanks and lower trunk, which showed tissue fibrosis of the flanks and abdomen regions. They were divided into two groups: Liposuction group and lipoabdominoplasty group. A total of twelve sessions of therapeutic ultrasound followed by the manual lymphatic drainage were performed. The patients were assessed with regard to pain, oedema and tissue fibrosis in different moments: Initial assessment, during assessment and final assessment through the application of the protocol of evaluation of cysts fibrosis levels. Statistical Analysis: The test of equality for two proportions and the confidence interval test for mean to evaluate the distribution of variables. The significance level adopted for statistical tests was 5% (P < 0.05. Results: There was a statistically significant reduction of pain, swelling and tissue fibrosis in both groups. Conclusion: the association between manual lymphatic drainage and the therapeutic ultrasound reduced the swelling and the tissue fibrosis and made pain disappear in liposuction and lipoabdominoplasty PO period.

  8. Hoisting and rigging manual: Uncontrolled document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-05-01

    This document is a draft copy of a Hoisting and Rigging Manual for the Department of Energy. The manual is divided into ten chapters. The chapter titles follow: terminology and definitions; operator training and qualification; overhead and gantry cranes; mobile cranes; forklift trucks; hoists; hooks; wire rope, slings, and rigging accessories; construction hoisting and rigging equipment requirements; references.

  9. Requirements to be met by the operation manual

    International Nuclear Information System (INIS)

    1981-03-01

    The rule applies to the contents and the lay-out of the operating manual for stationary nuclear power plants. The draft contains: 1. General requirement to be met by the contents of the operating manual. The operating manual to be arranged in 4 parts (part 1: internal rules and regulations; part 2: operation overall plant; part 3: incidents; part 4: operation systems). Safety specifications to be included in the manual, the exemption being the system of technical documentation. 2. General requirements to be met by the lay-out of the operating manual. Comprehensibility; legibility; structure and subdivisions; arrangement of the instructions and design of the manuals cover. 3. Requirements to be met by part 1. Defining the various internal rules and regulations (personnel management); rules and regulations concerning inspections and shift work; maintenance and repair; radiation protection; guard duty and admission; alarm; fire protection; first aid. 4. Requirements to be met by part 2. Provisions and operational limitations; limit values important from the point of view of safety; normal operation; anomalous operation; in-service inspections. 6. Requirements to be met by part 3. 7. Annex: Rules, regulations and stipulations mentioned in the rule draft. (orig.)

  10. Accountability methods for plutonium and uranium: the NRC manuals

    Energy Technology Data Exchange (ETDEWEB)

    Gutmacher, R.G.; Stephens, F.B.

    1977-09-28

    Four manuals containing methods for the accountability of plutonium nitrate solutions, plutonium dioxide, uranium dioxide and mixed uranium-plutonium oxide have been prepared by us and issued by the U.S. Nuclear Regulatory Commission. A similar manual on methods for the accountability of uranium and plutonium in reprocessing plant dissolver solutions is now in preparation. In the present paper, we discuss the contents of the previously issued manuals and give a preview of the manual now being prepared.

  11. Accountability methods for plutonium and uranium: the NRC manuals

    International Nuclear Information System (INIS)

    Gutmacher, R.G.; Stephens, F.B.

    1977-01-01

    Four manuals containing methods for the accountability of plutonium nitrate solutions, plutonium dioxide, uranium dioxide and mixed uranium-plutonium oxide have been prepared by us and issued by the U.S. Nuclear Regulatory Commission. A similar manual on methods for the accountability of uranium and plutonium in reprocessing plant dissolver solutions is now in preparation. In the present paper, we discuss the contents of the previously issued manuals and give a preview of the manual now being prepared

  12. Netbooks The Missing Manual

    CERN Document Server

    Biersdorfer, J

    2009-01-01

    Netbooks are the hot new thing in PCs -- small, inexpensive laptops designed for web browsing, email, and working with web-based programs. But chances are you don't know how to choose a netbook, let alone use one. Not to worry: with this Missing Manual, you'll learn which netbook is right for you and how to set it up and use it for everything from spreadsheets for work to hobbies like gaming and photo sharing. Netbooks: The Missing Manual provides easy-to-follow instructions and lots of advice to help you: Learn the basics for using a Windows- or Linux-based netbookConnect speakers, printe

  13. Aquifer thermal energy storage reference manual: seasonal thermal energy storage program

    Energy Technology Data Exchange (ETDEWEB)

    Prater, L.S.

    1980-01-01

    This is the reference manual of the Seasonal Thermal Energy Storage (STES) Program, and is the primary document for the transfer of technical information of the STES Program. It has been issued in preliminary form and will be updated periodically to include more technical data and results of research. As the program progresses and new technical data become available, sections of the manual will be revised to incorporate these data. This primary document contains summaries of: the TRW, incorporated demonstration project at Behtel, Alaska, Dames and Moore demonstration project at Stony Brook, New York, and the University of Minnesota demonstration project at Minneapolis-St. Paul, Minnesota; the technical support programs including legal/institutional assessment; economic assessment; environmental assessment; field test facilities; a compendia of existing information; numerical simulation; and non-aquifer STES concepts. (LCL)

  14. Radiological control technician: Training program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE Radiological Control Technician Core Training Program qualification and training process, material development requirements, standards and policies, and administration. The manual applies to Radiological Control Technician Training Programs at all DOE contractor sites

  15. Free manual of cadaver dissection modifiable by other anatomists.

    Science.gov (United States)

    Chung, Beom Sun; Chung, Min Suk

    2015-06-01

    Even in the rapidly changing field of cadaver dissection, published guide books still play an important role in the anatomy lab. However, commercial manuals with lengthy volumes and inflexible copyrights have several limitations which can be complemented by open-source manuals. Recently, the authors have manufactured and distributed a free electronic dissection manual (anatomy.co.kr), where descriptions are written concisely and images are drawn schematically. Moreover, simplified signs are employed to represent the cadaver viewing angles and manner of dissection. Based on the original files of this manual, other anatomists can revise and utilize the descriptions and figures. We expect many updated versions of our manual to be shared between students all over the world.

  16. Manual therapy and exercise for rotator cuff disease.

    Science.gov (United States)

    Page, Matthew J; Green, Sally; McBain, Brodwen; Surace, Stephen J; Deitch, Jessica; Lyttle, Nicolette; Mrocki, Marshall A; Buchbinder, Rachelle

    2016-06-10

    Management of rotator cuff disease often includes manual therapy and exercise, usually delivered together as components of a physical therapy intervention. This review is one of a series of reviews that form an update of the Cochrane review, 'Physiotherapy interventions for shoulder pain'. To synthesise available evidence regarding the benefits and harms of manual therapy and exercise, alone or in combination, for the treatment of people with rotator cuff disease. We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (January 1966 to March 2015), Ovid EMBASE (January 1980 to March 2015), CINAHL Plus (EBSCO, January 1937 to March 2015), ClinicalTrials.gov and the WHO ICTRP clinical trials registries up to March 2015, unrestricted by language, and reviewed the reference lists of review articles and retrieved trials, to identify potentially relevant trials. We included randomised and quasi-randomised trials, including adults with rotator cuff disease, and comparing any manual therapy or exercise intervention with placebo, no intervention, a different type of manual therapy or exercise or any other intervention (e.g. glucocorticoid injection). Interventions included mobilisation, manipulation and supervised or home exercises. Trials investigating the primary or add-on effect of manual therapy and exercise were the main comparisons of interest. Main outcomes of interest were overall pain, function, pain on motion, patient-reported global assessment of treatment success, quality of life and the number of participants experiencing adverse events. Two review authors independently selected trials for inclusion, extracted the data, performed a risk of bias assessment and assessed the quality of the body of evidence for the main outcomes using the GRADE approach. We included 60 trials (3620 participants), although only 10 addressed the main comparisons of interest. Overall risk of bias was low in three, unclear in 14 and high in

  17. HASL procedures manual

    International Nuclear Information System (INIS)

    1980-08-01

    Addition and corrections to the following sections of the HASL Procedures Manual are provided: Table of Contents; Bibliography; Fallout Collection Methods; Wet/Dry Fallout Collection; Fluoride in Soil and Sediment; Strontium-90; Natural Series; Alpha Emitters; and Gamma Emitters

  18. EMAP Users Manual.

    Science.gov (United States)

    Kotz, Arnold; Redondo, Rory

    Presented is the user's manual for the Educational Manpower Information Sources Project (EMAP), an information file containing approximately 325 document abstracts related to the field of educational planning. (The EMAP file is described in document SP 006 747.) (JB)

  19. CALENDF-2010: user manual

    International Nuclear Information System (INIS)

    Sublet, Jean-Christophe; Ribon, Pierre; Coste-Delclaux, Mireille

    2011-09-01

    CALENDF-2010 represents a Fortran-95 update of the 1994, 2001 then 2005 code distribution with emphasise on programming quality and standards, physics and usage improvements. Devised to process multigroup cross-sections it relies on Gauss quadrature mathematical principle and strength. The followings processes can be handled by the code: moment probability table and effective cross-section calculation; pointwise cross section, probability table and effective cross-section regrouping; probability table condensation; probability table mix for several isotopes; probability table interpolation; effective cross section based probability table calculations; probability table calculations from effective cross-sections; cross-section comparison, complete energy pointwise cross-section processing and thickness dependent averaged transmission sample calculation. The CALENDF user manual, after having listed all principal code functions, describes sequentially each of them and gives comments on their associated output streams. Installation procedures, test cases and running time platform comparisons are given in the appendix. (authors)

  20. The performance of an automatic acoustic-based program classifier compared to hearing aid users' manual selection of listening programs.

    Science.gov (United States)

    Searchfield, Grant D; Linford, Tania; Kobayashi, Kei; Crowhen, David; Latzel, Matthias

    2018-03-01

    To compare preference for and performance of manually selected programmes to an automatic sound classifier, the Phonak AutoSense OS. A single blind repeated measures study. Participants were fit with Phonak Virto V90 ITE aids; preferences for different listening programmes were compared across four different sound scenarios (speech in: quiet, noise, loud noise and a car). Following a 4-week trial preferences were reassessed and the users preferred programme was compared to the automatic classifier for sound quality and hearing in noise (HINT test) using a 12 loudspeaker array. Twenty-five participants with symmetrical moderate-severe sensorineural hearing loss. Participant preferences of manual programme for scenarios varied considerably between and within sessions. A HINT Speech Reception Threshold (SRT) advantage was observed for the automatic classifier over participant's manual selection for speech in quiet, loud noise and car noise. Sound quality ratings were similar for both manual and automatic selections. The use of a sound classifier is a viable alternative to manual programme selection.

  1. Caspase-9 mediates synaptic plasticity and memory deficits of Danish dementia knock-in mice: caspase-9 inhibition provides therapeutic protection

    Directory of Open Access Journals (Sweden)

    Tamayev Robert

    2012-12-01

    Full Text Available Abstract Background Mutations in either Aβ Precursor protein (APP or genes that regulate APP processing, such as BRI2/ITM2B and PSEN1/PSEN2, cause familial dementias. Although dementias due to APP/PSEN1/PSEN2 mutations are classified as familial Alzheimer disease (FAD and those due to mutations in BRI2/ITM2B as British and Danish dementias (FBD, FDD, data suggest that these diseases have a common pathogenesis involving toxic APP metabolites. It was previously shown that FAD mutations in APP and PSENs promote activation of caspases leading to the hypothesis that aberrant caspase activation could participate in AD pathogenesis. Results Here, we tested whether a similar mechanism applies to the Danish BRI2/ITM2B mutation. We have generated a genetically congruous mouse model of FDD, called FDDKI, which presents memory and synaptic plasticity deficits. We found that caspase-9 is activated in hippocampal synaptic fractions of FDDKI mice and inhibition of caspase-9 activity rescues both synaptic plasticity and memory deficits. Conclusion These data directly implicate caspase-9 in the pathogenesis of Danish dementia and suggest that reducing caspase-9 activity is a valid therapeutic approach to treating human dementias.

  2. Manually Ventilating Test” in Anesthesia Management of Children with Massive Anterior Mediastinal Masses Requiring Tracheal Intubation.A case series

    Directory of Open Access Journals (Sweden)

    Mohammad Gharavi

    2014-08-01

    Full Text Available The risk of life-threatening complications during induction of anesthesia in patients with anterior mediastinal mass is well recognized. Maintenance of spontaneous ventilation during anesthesia is an accepted standard goal in all published reports. However, the decision to paralyze the patient, which is really needed in most surgical procedures, is still a challenging event. In this study, “manually ventilating test” as a predictive test was assessed to make the decision to paralyze children with massive anterior mediastinal masses who needed tracheal intubation. . It seems that manually ventilating test may at least be a simple and reliable test to identify cases that could be paralyzed successfully

  3. Operation manual for the INEL on-line mass-separator facility

    International Nuclear Information System (INIS)

    Anderl, R.A.

    1984-06-01

    This report is an operation manual for an on-line mass-separator facility which is located in Building 661 at the Test Reactor Area of the Idaho National Engineering Laboratory. The facility provides mass-separated sources of short-lived fission-product radionuclides whose decay properties can be studied using a variety of nuclear spectroscopic techniques. This facility is unique in that it utilizes the gas-jet technique to transport fission products from a 252 Cf source located in a hot cell to the ion source of the mass separator. This document includes the following: (a) a detailed description of the facility, (b) identification of equipment hazards and safety controls, (c) detailed operating procedures for startup, continuous operation and shutdown, (d) operating procedures for the californium hot cell, and (e) an operator's manual for the automated moving tape collector/data acquisition system. 7 references, 16 figures, 8 tables

  4. 21 CFR 864.6160 - Manual blood cell counting device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual blood cell counting device. 864.6160 Section 864.6160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6160 Manual...

  5. Develpment of quality assurance manual for fabrication of DUPIC fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT.

  6. Develpment of quality assurance manual for fabrication of DUPIC fuel

    International Nuclear Information System (INIS)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT

  7. The relationship between walking, manual dexterity, cognition and activity/participation in persons with multiple sclerosis.

    Science.gov (United States)

    Kierkegaard, Marie; Einarsson, Ulrika; Gottberg, Kristina; von Koch, Lena; Holmqvist, Lotta Widén

    2012-05-01

    Multiple sclerosis has a vast impact on health, but the relationship between walking, manual dexterity, cognition and activity/participation is unclear. The specific aims were to explore the discriminative ability of measures of walking, manual dexterity and cognition, and to identify cut-off values in these measures, for prediction of independence in personal and instrumental activities of daily living (ADL) and activity/participation in social and lifestyle activities. Data from 164 persons with multiple sclerosis were collected during home visits with the following measures: the 2 × 5 m walk test, the Nine-hole Peg Test, the Symbol Digit Modalities Test, the Katz Personal and Instrumental ADL Indexes, and the Frenchay Activities Index (measuring frequency in social and lifestyle activities). The 2 × 5 m walk test and the Nine-hole Peg Test had high and better discriminative and predictive ability than the Symbol Digit Modalities Test. Cut-off values were identified. The accuracy of predictions was increased above all by combining the 2 × 5 m walk test and the Nine-hole Peg Test. The proposed cut-off values in the 2 × 5 m walk test and the Nine-hole Peg Test may be used as indicators of functioning and to identify persons risking activity limitations and participation restrictions. However, further studies are needed to confirm the usefulness in clinical practice.

  8. High-resolution modelling of health impacts and related external cost from air pollution using the integrated model system EVA

    DEFF Research Database (Denmark)

    Brandt, Jørgen; Andersen, Mikael Skou; Bønløkke, Jakob

    2015-01-01

    Proceedings from ITM 2015, 34th International Technical Meeting on Air Pollution Modelling and its Application. 4-8 May, 2015, Montpellier, France. 4 pp......Proceedings from ITM 2015, 34th International Technical Meeting on Air Pollution Modelling and its Application. 4-8 May, 2015, Montpellier, France. 4 pp...

  9. Operating manual for the Bulk Shielding Reactor

    International Nuclear Information System (INIS)

    1983-04-01

    The BSR is a pool-type reactor. It has the capabilities of continuous operation at a power level of 2 MW or at any desired lower power level. This manual presents descriptive and operational information. The reactor and its auxillary facilities are described from physical and operational viewpoints. Detailed operating procedures are included which are applicable from source-level startup to full-power operation. Also included are procedures relative to the safety of personnel and equipment in the areas of experiments, radiation and contamination control, emergency actions, and general safety. This manual supercedes all previous operating manuals for the BSR

  10. Operating manual for the Bulk Shielding Reactor

    International Nuclear Information System (INIS)

    1987-03-01

    The BSR is a pool-type reactor. It has the capabilities of continuous operation at a power level of 2 MW or at any desired lower power level. This manual presents descriptive and operational information. The reactor and its auxiliary facilities are described from physical and operational viewpoints. Detailed operating procedures are included which are applicable from source-level startup to full-power operation. Also included are procedures relative to the safety of personnel and equipment in the areas of experiments, radiation and contamination control, emergency actions, and general safety. This manual supersedes all previous operating manuals for the BSR

  11. Operating manual for the Bulk Shielding Reactor

    Energy Technology Data Exchange (ETDEWEB)

    1987-03-01

    The BSR is a pool-type reactor. It has the capabilities of continuous operation at a power level of 2 MW or at any desired lower power level. This manual presents descriptive and operational information. The reactor and its auxiliary facilities are described from physical and operational viewpoints. Detailed operating procedures are included which are applicable from source-level startup to full-power operation. Also included are procedures relative to the safety of personnel and equipment in the areas of experiments, radiation and contamination control, emergency actions, and general safety. This manual supersedes all previous operating manuals for the BSR.

  12. Operating manual for the Bulk Shielding Reactor

    Energy Technology Data Exchange (ETDEWEB)

    1983-04-01

    The BSR is a pool-type reactor. It has the capabilities of continuous operation at a power level of 2 MW or at any desired lower power level. This manual presents descriptive and operational information. The reactor and its auxillary facilities are described from physical and operational viewpoints. Detailed operating procedures are included which are applicable from source-level startup to full-power operation. Also included are procedures relative to the safety of personnel and equipment in the areas of experiments, radiation and contamination control, emergency actions, and general safety. This manual supercedes all previous operating manuals for the BSR.

  13. A user's manual to the PMBOK guide

    CERN Document Server

    Stackpole Snyder, Cynthia

    2013-01-01

    The must-have manual to understand and use the latest edition of the Fifth Edition The professional standard in the field of project management, A Guide to the Project Management Body of Knowledge (PMBOK® Guide-Fifth Edition) published by the Project Management Institute (PMI) serves as the ultimate resource for professionals and as a valuable studying and training device for students taking the PMP® Exam. A User''s Manual to the PMBOK® Guide takes the next logical step to act as a true user''s manual. With an accessible format and easy-to-understand language, it helps to not only distill es

  14. Increasing Orgasm and Decreasing Dyspareunia by a Manual Physical Therapy Technique

    Science.gov (United States)

    Wurn, Lawrence J; Wurn, Belinda F; Roscow, Amanda S; King, C Richard; Scharf, Eugenia S; Shuster, Jonathan J

    2004-01-01

    Context Female sexual pain and dysfunction Objective To evaluate the effectiveness of a new site-specific, manual soft-tissue therapy in increasing orgasm and reducing dyspareunia (painful intercourse) in women with histories indicating abdominopelvic adhesion formation. Design and Intervention A total of 29 new patients presenting with infertility or abdominopelvic pain-related problems, and also indicating sexual pain or dysfunction, received a series of treatments (mean, 19.5 hours) designed to address biomechanical dysfunction and restricted mobility due to adhesions affecting the reproductive organs and adjacent structures. Outcome Measures Primary outcome measures were post-test vs pretest scores on: (1) the Female Sexual Function Index (FSFI) full scale, orgasm domain, and pain domain; and (2) 3 supplemental 10-point rating scales of sexual pain levels. Secondary outcome measures were post-test vs pretest scores in the other 4 FSFI domains (desire, arousal, lubrication, and satisfaction). The Wilcoxon signed-rank test was used for all statistical analyses. Results For the 23 patients available for follow-up, the paired FSFI post-test vs pretest scores were significant (P ≤ .003) on all measures. Of the 17 patients who completed the 3 sexual pain scales, the paired post-test vs pretest scores were significant (P ≤ .002) Conclusions Many cases of inhibited orgasm, dyspareunia, and other aspects of sexual dysfunction seem to be treatable by a distinctive, noninvasive manual therapy with no risks and few, if any, adverse effects. The therapy should be considered a new adjunct to existing gynecologic and medical treatments. PMID:15775874

  15. Training Psychiatry Residents in Psychotherapy: The Role of Manualized Treatments.

    Science.gov (United States)

    Pagano, Joshua; Kyle, Brandon N; Johnson, Toni L; Saeed, Sy Atezaz

    2017-06-01

    Evidence-based treatment and manualized psychotherapy have a recent but rich history. As interest and research have progressed, defining the role of treatment manuals in resident training and clinical practice has become more important. Although there is not a universal definition of treatment manual, most clinicians and researchers agree that treatment manuals are an essential piece of evidence-based therapy, and that despite several limitations, they offer advantages in training residents in psychotherapy. Requirements for resident training in psychotherapy have changed over the years, and treatment manuals offer a simple and straightforward way to meet training requirements. In a search limited to only depression, two treatment manuals emerged with the support of research regarding both clinical practice and resident training. In looking toward the future, it will be important for clinicians to remain updated on further advances in evidence based manualized treatment as a tool for training residents in psychotherapy, including recent developments in online and smartphone based treatments.

  16. Auxiliary mine ventilation manual

    International Nuclear Information System (INIS)

    Workplace Safety North

    2010-01-01

    An adequate ventilation system is needed for air quality and handling in a mine and is comprised of many different pieces of equipment for removing contaminated air and supplying fresh air and thereby provide a satisfactory working environment. This manual highlights auxiliary ventilation systems made up of small fans, ducts, tubes, air movers, deflectors and additional air flow controls which distribute fresh air delivered by the primary system to all areas. A review of auxiliary ventilation is provided. Design, operation and management issues are discussed and guidelines are furnished. This manual is limited to underground hard rock operations and does not address directly other, specific auxiliary systems, either in underground coal mines or uranium mines.

  17. Auxiliary mine ventilation manual

    Energy Technology Data Exchange (ETDEWEB)

    Workplace Safety North

    2010-07-01

    An adequate ventilation system is needed for air quality and handling in a mine and is comprised of many different pieces of equipment for removing contaminated air and supplying fresh air and thereby provide a satisfactory working environment. This manual highlights auxiliary ventilation systems made up of small fans, ducts, tubes, air movers, deflectors and additional air flow controls which distribute fresh air delivered by the primary system to all areas. A review of auxiliary ventilation is provided. Design, operation and management issues are discussed and guidelines are furnished. This manual is limited to underground hard rock operations and does not address directly other, specific auxiliary systems, either in underground coal mines or uranium mines.

  18. Manual airway labeling has limited reproducibility

    DEFF Research Database (Denmark)

    Petersen, Jens; Feragen, Aasa; Thomsen, Laura Hohwü

    Purpose: Quantitative airway assessment is often performed in specific branches to enable comparison of measurements between patients and over time. Little is known on the accuracy in locating these branches. We determined inter- and intra-observer agreement of manual labeling of segmental bronch...... disagreement in expert labeling, possibly reflecting large anatomical heterogeneity and changes with inspiration. Consistent airway measurement cannot be guaranteed based on manual localization....

  19. MINTEQ user's manual

    International Nuclear Information System (INIS)

    Peterson, S.R.; Hostetler, C.J.; Deutsch, W.J.; Cowan, C.E.

    1987-02-01

    This manual will aid the user in applying the MINTEQ geochemical computer code to model aqueous solutions and the interactions of aqueous solutions with hypothesized assemblages of solid phases. The manual will provide a basic understanding of how the MINTEQ computer code operates and the important principles that are incorporated into the code and instruct a user of the MINTEQ code on how to create input files to simulate a variety of geochemical problems. Chapters 2 through 8 are for the user who has some experience with or wishes to review the principles important to geochemical computer codes. These chapters include information on the methodology MINTEQ uses to incorporate these principles into the code. Chapters 9 through 11 are for the user who wants to know how to create input data files to model various types of problems. 35 refs., 2 figs., 5 tabs

  20. Developing hospital identity manuals: a reference tool for illustrators.

    Science.gov (United States)

    Schaffer, J A; Zimmerman, S B

    1990-01-01

    Because of an increase in hospital marketing efforts, medical illustrators may be asked to assist in developing and implementing hospital identity manuals, which specify the graphic standards for visual communications media. A checklist survey of existing identity manuals and a literature review were conducted by one of the authors, a medical illustrator, to help her to develop a manual for her hospital employer. This article documents the literature review, the study, and the identity manual development, and presents recommendations to help other medical illustrators who might become involved in similar assignments.

  1. The computer code Eurdyn - 1 M. (Release 1) Part 2: User's Manual

    International Nuclear Information System (INIS)

    Donea, J.; Giuliani, S.

    1979-01-01

    This report is the user's manual for the computer code Eurdyn-1 M developed at the J.R.C. Ispra for use in containment and fuel subassembly analyses for fast reactor safety studies. The input data are defined and a test problem is presented to illustrate both the input and the output of results

  2. 14 CFR 21.5 - Airplane or Rotorcraft Flight Manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Airplane or Rotorcraft Flight Manual. 21.5... CERTIFICATION PROCEDURES FOR PRODUCTS AND PARTS General § 21.5 Airplane or Rotorcraft Flight Manual. (a) With each airplane or rotorcraft that was not type certificated with an Airplane or Rotorcraft Flight Manual...

  3. Comparison between rotary and manual instrumentation in primary teeth.

    Science.gov (United States)

    Crespo, S; Cortes, O; Garcia, C; Perez, L

    2008-01-01

    The aim of this study was to compare the efficiency in both, preparation time and root canal shape, when using the Nickel Titanium (Ni-Ti) rotary and K-Files hand instrumentation on root canal preparation of single rooted primary teeth. Sixty single rooted primary teeth were selected and divided into two equal groups: Group (I) 30 teeth instrumented with manual K-files and group (II) 30 teeth instrumented with Ni-Ti rotary files (ProFile 0.04). Instrumentation times were calculated and root canal impressions were taken with light bodied silicone in order to evaluate the shape. The data was analyzed with SPSS program using the t-test and the Chi-square test to compare their means. The preparation time with group (I) K-files was significantly higher than in group (II) rotary files (ProFile 0.04), with a p= .005. The ProFile system showed a significantly more favorable canal taper when compared to the K-files system (P= .002). The use of rotary files in primary teeth has several advantages when compared with manual K files: the efficiency in both, preparation time and root canal shape. 1. A decreased working time, that helps maintain patient cooperation by diminishing the potential for tiredness. 2. The shape of the root canal is more conical, favoring a higher quality of the root canal filling, and increasing clinical success.

  4. Science Library of Test Items. Volume Three. Mastery Testing Programme. Introduction and Manual.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    A set of short tests aimed at measuring student mastery of specific skills in the natural sciences are presented with a description of the mastery program's purposes, development, and methods. Mastery learning, criterion-referenced testing, and the scope of skills to be tested are defined. Each of the multiple choice tests for grades 7 through 10…

  5. Salinas. Theory Manual Version 2.8

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Garth M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walsh, Timothy [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bhardwaj, Manoj K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2009-02-01

    Salinas provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas , we refer the reader to Salinas, Users Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature.

  6. Design manual for management of solid by-products from advanced coal technologies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-01

    Developing coal conversion technologies face major obstacles in byproduct management. This project has developed several management strategies based on field trials of small-scale landfills in an earlier phase of the project, as well as on published/unpublished sources detailing regulatory issues, current industry practice, and reuse opportunities. Field testing, which forms the basis for several of the disposal alternatives presented in this design manual, was limited to byproducts from Ca-based dry SO{sub 2} control technologies, circulating fluidized bed combustion ash, and bubbling bed fluidized bed combustion ash. Data on byproducts from other advanced coal technologies and on reuse opportunities are drawn from other sources (citations following Chapter 3). Field results from the 5 test cases examined under this project, together with results from other ongoing research, provide a basis for predictive modeling of long-term performance of some advanced coal byproducts on exposure to ambient environment. This manual is intended to provide a reference database and development plan for designing, permitting, and operating facilities where advanced coal technology byproducts are managed.

  7. Military construction program economic analysis manual: Sample economic analyses: Hazardous Waste Remedial Actions Program

    International Nuclear Information System (INIS)

    1987-12-01

    This manual enables the US Air Force to comprehensively and systematically analyze alternative approaches to meeting its military construction requirements. The manual includes step-by-step procedures for completing economic analyses for military construction projects, beginning with determining if an analysis is necessary. Instructions and a checklist of the tasks involved for each step are provided; and examples of calculations and illustrations of completed forms are included. The manual explains the major tasks of an economic analysis, including identifying the problem, selecting realistic alternatives for solving it, formulating appropriate assumptions, determining the costs and benefits of the alternatives, comparing the alternatives, testing the sensitivity of major uncertainties, and ranking the alternatives. Appendixes are included that contain data, indexes, and worksheets to aid in performing the economic analyses. For reference, Volume 2 contains sample economic analyses that illustrate how each form is filled out and that include a complete example of the documentation required

  8. Military construction program economic analysis manual: Text and appendixes: Hazardous Waste Remedial Actions Program

    International Nuclear Information System (INIS)

    1987-12-01

    This manual enables the US Air Force to comprehensively and systematically analyze alternative approaches to meeting its military construction requirements. The manual includes step-by-step procedures for completing economic analyses for military construction projects, beginning with determining if an analysis is necessary. Instructions and a checklist of the tasks involved for each step are provided; and examples of calculations and illustrations of completed forms are included. The manual explains the major tasks of an economic analysis, including identifying the problem, selecting realistic alternatives for solving it, formulating appropriate assumptions, determining the costs and benefits of the alternatives, comparing the alternatives, testing the sensitivity of major uncertainties, and ranking the alternatives. Appendixes are included that contain data, indexes, and worksheets to aid in performing the economic analyses. For reference, Volume 2 contains sample economic analyses that illustrate how each form is filled out and that include a complete example of the documentation required. 6 figs., 12 tabs

  9. Fast matching of sensor data with manual observations.

    Science.gov (United States)

    Jit, Biswas; Maniyeri, Jayachandran; Louis, Shue; Philip, Yap Lin Kiat

    2009-01-01

    In systems and trials concerning wearable sensors and devices used for medical data collection, the validation of sensor data with respect to manual observations is very important. However, this is often problematic because of feigned behavior, errors in manual recording (misclassification), gaps in recording (missing readings), missed observations and timing mismatch between manual observations and sensor data due to a difference in time granularity. Using sleep activity pattern monitoring as an example we present a fast algorithm for matching sensor data with manual observations. Major components include a) signal analysis to classify states of sleep activity pattern, b) matching of states with Sleep Diary (SD) and c) automated detection of anomalies and reconciliation of mismatches between the SD and the sensor data.

  10. Demonstration test of in-service inspection methods

    International Nuclear Information System (INIS)

    Takumi, Kenji

    1987-01-01

    The major objectives of the project are: (1) to demonstrate the reliability of a manual ultrasonic flaw detector and techniques that are used in operating light water reactor plants and (2) to demonstrate the performance and reliability of an automatic ultrasonic flaw detector that is designed to shorten the time required for ISI work and reduce the exposure risk of inspection personnel. The test project consists of three stages. In the first stage, which ended in 1982, defects were added intentionally to a model structure the same in size as a typical 1.1 million kW BWR plant and manual ultrasonic flaw detection tensting was performed. In the second stage, completed in 1984, automatic eddy-current flaw detection testing was carried out for defects in heat transfer piping of a PWP steam generator. In the third stage, which started in 1981 and ended in March 1987, a newly developed automatic ultrasonic flaw detector is applied to testing of defects used for the manual detector performance evaluation. Results have shown that the automatic eddy-current flaw detector under test has an adequately stable performance for practical uses, with a very high reproducibility to permit close inspection of secular deterioration in heat transfer pipes. It has also revealed that both the manual and automatic ultrasonic flaw detectors under test can detect all defects that do not comply with the ASME standards. (Nogami, K.)

  11. Elaboração de um manual ilustrado de exercícios domiciliares para pacientes com hemiparesia secundária ao acidente vascular encefálico (AVE Elaboration of an illustrated home exercise manual for stroke patients with hemiparesis

    Directory of Open Access Journals (Sweden)

    Adriana Maria Barsante Santos

    2012-03-01

    Full Text Available A realização de exercícios físicos para pacientes com sequelas motoras pós-acidente vascular encefálico (AVE é essencial para a recuperação funcional. Programas educacionais podem facilitar a repetição dos exercícios em casa e contribuir para o tratamento. Este trabalho teve como objetivo elaborar e aplicar um manual de exercícios domiciliares para pacientes com AVE. O estudo consistiu em duas etapas: na primeira foi elaborado um manual de exercícios domiciliares (piloto com fotos e textos simples para facilitar a compreensão. Foi realizada uma avaliação funcional de cada paciente e selecionados os exercícios mais adequados, que deveriam ser feitos em casa. Esse manual foi aplicado a 17 pacientes, 70% crônicos e 30% agudos. Após 15 dias, o paciente retornava e era solicitado que reproduzisse os exercícios e informasse o nível de compreensão das fotos e do texto do manual e se sentia dor ao realizá-los. As fotos e os exercícios referidos como difíceis foram revistos, e criada a versão teste que foi aplicada em outros 23 pacientes, dando origem à versão final do manual. A avaliação do manual piloto foi insatisfatória, sendo que apenas 56% referiram aprovação das fotos e 87% do texto. Após a reformulação, a compreensão das fotos e do texto alcançou valores acima de 98%. Foi possível obter um manual ilustrado de exercícios domiciliares, de fácil aplicação e compreensão, específico e individualizado, para pacientes com AVE e adaptável aos diferentes quadros motores.The practice of exercises for patients with motor sequels post-stroke is essential for the functional recovery. Educational programs can facilitate the repetition of the exercises at home and contribute to the treatment. The objective of this study was to elaborate a home exercise manual for stroke patients. The study consisted of two stages: in the first one, a home exercise manual was made (pilot with pictures and simple text to facilitate

  12. Kajian Proses Pembuatan Perhiasan Perak Cara Manual dan Masinal

    Directory of Open Access Journals (Sweden)

    Joni Setiawan

    2016-04-01

    Full Text Available Perhiasan dapat dibuat dengan 2 cara yaitu manual dan masinal. Masing-masing cara mempunyai kekurangan dan kelebihan. Oleh karena itu perlu adanya kajian dari dua cara tersebut sehingga bisa mengetahui cara apa yang lebih optimal dalam memproduksi perhiasan. Dalam kajian ini perhiasan yang dibuat adalah cincin dengan bahan perak 100 gram dan dicampur dengan tembaga 5 gram dengan 2 (dua model yaitu model A (cincin motif polos dan model B (cincin motif parang.Metode yang dipakai adalah dengan membandingkan hasil produk dari dua cara tersebut. Parameter yang dibandingkan adalah kualitas, waktu dan biaya dari produk tersebut.Hasil kajian menunjukkan bahwa kadar produk rata-rata dengan cara masinal lebih tlnggi 1,25%dibanding cara manual, dimensi produk rata-rata dengan cara masinal lebih presisi dibanding cara manual. Waktu proses rata-rata dengan cara masinal lebih cepat 97% dibanding cara manual dan biaya produksi cara masinal lebih rendah 63% dibanding cara manual.Dengan melihat hasil kajian tersebut maka dapat disimpulkan bahwa cara masinal lebih efisien dan efektif dibanding cara manual.

  13. Spanish for Agricultural Purposes: The Basic Manual.

    Science.gov (United States)

    Mainous, Bruce H.; And Others

    This manual, part of a one-semester course for North American agriculture specialists preparing to work in Latin America, is built around specimens of agricultural writing in Spanish. The manual contains 12 lessons on general agriculture, sugar production, grain production, geography, forestry, animal husbandry, soy bean production, agricultural…

  14. A Manual for Teachers of Indochinese Students.

    Science.gov (United States)

    Phap, Dam Trung

    This is a manual for teachers of Indochinese students. The manual begins with brief cultural, linguistic, and historical descriptions of Vietnam, Laos, and Cambodian people. The tenets of animism, Buddhism, Taoism, Confucianism, and Christianity, as practiced in Indochina are reviewed. Also discussed are Indochinese attitudes toward learning and…

  15. Fast Uncooled Low Density FPA of VPD PbSe for Applications in Hyperspectral Imagery

    Science.gov (United States)

    2009-10-01

    Marañosa (ITM-CIDA). Area de Optronica y Acustica Unidad de Sensores y Micro-Nano Tecnologia Arturo Soria, 289 E-28033 Madrid, Spain ABSTRACT...ADDRESS(ES) Instituto Tecnologico de la Marañosa (ITM-CIDA). Area de Optronica y Acustica Unidad de Sensores y Micro-Nano Tecnologia Arturo Soria, 289

  16. Role of Proteasome-Dependent Protein Degradation in Long-Term Operant Memory in "Aplysia"

    Science.gov (United States)

    Lyons, Lisa C.; Gardner, Jacob S.; Gandour, Catherine E.; Krishnan, Harini C.

    2017-01-01

    We investigated the in vivo role of protein degradation during intermediate (ITM) and long-term memory (LTM) in "Aplysia" using an operant learning paradigm. The proteasome inhibitor MG-132 inhibited the induction and molecular consolidation of LTM with no effect on ITM. Remarkably, maintenance of steady-state protein levels through…

  17. A user's manual for the database management system of impact property

    International Nuclear Information System (INIS)

    Ryu, Woo Seok; Park, S. J.; Kong, W. S.; Jun, I.

    2003-06-01

    This manual is written for the management and maintenance of the impact database system for managing the impact property test data. The data base constructed the data produced from impact property test can increase the application of test results. Also, we can get easily the basic data from database when we prepare the new experiment and can produce better result by compare the previous data. To develop the database we must analyze and design carefully application and after that, we can offer the best quality to customers various requirements. The impact database system was developed by internet method using jsp(Java Server pages) tool

  18. Fuerza manual de adultos con discapacidad intelectual

    Directory of Open Access Journals (Sweden)

    Ruth Cabeza Ruiz

    2017-09-01

    Full Text Available Objetivo. Presentar una descripción de la fuerza de prensión manual de hombres y mujeres con discapacidad intelectual (DI y comparar los resultados con valores de referencia de otras personas con y sin discapacidad intelectual. Método. El presente trabajo es un estudio transversal observacional, financiado por la Fundación SAMU, en el que se evaluaron a 122 personas con DI (86 hombres y 36 mujeres durante el desarrollo de unas jornadas de carácter recreativo en las que participaron varias asociaciones de atención a este colectivo. La batería de test utilizada fue el Alpaha-Fit Test Battery for Adults. Resultados. Se presentan los resultados relacionados con las variables de fuerza del miembro superior (Hand Grip Strength por grupos de edad (20-24, 25- 29, 30-34, 35-39, 40-44, 45-49, 50-54, 55-59 años. Los datos muestran valores que oscilan desde los 31 kg en los hombres más jóvenes con DI hasta los 13.3 kg del grupo más maduro de mujeres. Estos hallazgos son similares a los valores de referencia de población con DI española. Sin embargo, son muy inferiores a los obtenidos por la población sin discapacidad de la misma edad. Conclusión. Los resultados evidencian el menor rendimiento de las personas con DI en pruebas de fuerza de prensión manual por lo que se hace evidente la necesidad de llevar a cabo programas de ejercicio físico o deporte con las personas con DI.

  19. PFP MICON maintenance manual. Revision 1

    International Nuclear Information System (INIS)

    Silvan, G.R.

    1995-01-01

    This manual covers the use of maintenance displays, maintenance procedures, system alarms and common system failures. This manual is intended to supplement the MICON maintenance training not replace it. It also assumes that the user is familiar with the normal operation of the MICON A/S system. The MICON system is a distributed control computer and, among other things, controls the HVAC system for the Plutonium Finishing Plant

  20. Axillary Hodgkin's disease in manual workers.

    Science.gov (United States)

    Andrieu, J M; Weh, H J; Teillet, F; Asselain, B

    1979-01-01

    Between 1965 and 1974, 16 patients were clinically staged as having unique axillary localizations of Hodgkin's disease. Sex ratio (4.3), mean age (40.8 years) and professional occupations (12 out of the 16 patients were engaged in manual work) were significantly different from that of all patients observed during the same period. These facts lead us to suppose the existence of a link between manual work and initial axillary localizations.

  1. Pollutant Assessments Group procedures manual: Volume 2, Technical procedures

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    This is volume 2 of the manuals that describes the technical procedures currently in use by the Pollution Assessments Group. This manual incorporates new developments in hazardous waste assessment technology and administrative policy. Descriptions of the equipment, procedures and operations of such things as radiation detection, soil sampling, radionuclide monitoring, and equipment decontamination are included in this manual. (MB)

  2. Quality manual. Nuclear Regulatory Authority of the Slovak Republic

    International Nuclear Information System (INIS)

    2006-03-01

    This quality manual of the Nuclear Regulatory Authority of the Slovak Republic (UJD) is presented. Basic characteristics of the UJD, Quality manual operative control, and Quality management system (QMS) are described. Management responsibility, Processes realization, Measurement, analysis (assessment) and improvement of the quality management system, Cancellation provision as well as abbreviations used in the Quality Manual are presented.

  3. Comparison of Manual Mapping and Automated Object-Based Image Analysis of Non-Submerged Aquatic Vegetation from Very-High-Resolution UAS Images

    Directory of Open Access Journals (Sweden)

    Eva Husson

    2016-09-01

    Full Text Available Aquatic vegetation has important ecological and regulatory functions and should be monitored in order to detect ecosystem changes. Field data collection is often costly and time-consuming; remote sensing with unmanned aircraft systems (UASs provides aerial images with sub-decimetre resolution and offers a potential data source for vegetation mapping. In a manual mapping approach, UAS true-colour images with 5-cm-resolution pixels allowed for the identification of non-submerged aquatic vegetation at the species level. However, manual mapping is labour-intensive, and while automated classification methods are available, they have rarely been evaluated for aquatic vegetation, particularly at the scale of individual vegetation stands. We evaluated classification accuracy and time-efficiency for mapping non-submerged aquatic vegetation at three levels of detail at five test sites (100 m × 100 m differing in vegetation complexity. We used object-based image analysis and tested two classification methods (threshold classification and Random Forest using eCognition®. The automated classification results were compared to results from manual mapping. Using threshold classification, overall accuracy at the five test sites ranged from 93% to 99% for the water-versus-vegetation level and from 62% to 90% for the growth-form level. Using Random Forest classification, overall accuracy ranged from 56% to 94% for the growth-form level and from 52% to 75% for the dominant-taxon level. Overall classification accuracy decreased with increasing vegetation complexity. In test sites with more complex vegetation, automated classification was more time-efficient than manual mapping. This study demonstrated that automated classification of non-submerged aquatic vegetation from true-colour UAS images was feasible, indicating good potential for operative mapping of aquatic vegetation. When choosing the preferred mapping method (manual versus automated the desired level of

  4. Postural adjustments are modulated by manual task complexity

    Directory of Open Access Journals (Sweden)

    Luis Augusto Teixeira

    2009-09-01

    Full Text Available Daily life activities of humans are characterized by dual tasks, in which a manual task is performed concomitantly with a postural task. Based on the assumption that both manual and postural tasks require attentional resources, no consensus exists as to how the central nervous system modulates postural adjustments in dual tasks. The aim of the present study was to analyze the effect of a manual task requiring attentional resources on shoulder and ankle adjustments as a function of the direction and predictability of postural perturbation. The participants (n=6 were evaluated during the performance of a simple and a complex manual task, while the base of support was moved backward or forward. Latency of activation of the tibialis anterior and gastroc-nemius muscles and angular acceleration of the shoulder were analyzed. The results showed that execution of the complex manual task delayed postural adjustment. Moreover, this delay occurred differently depending on the direction of postural perturbation. The delay in postural adjustment occurred proximally in the case of anterior displacement of the platform, and distally in the case of posterior displacement. Postural adjustments were more affected by the attentional task than by the predictability of platform displacement. These results are consistent with the concept of an integrated control between manual actions and the maintenance of static posture.

  5. Welding of Armor. Summary of Ballistic Shock Test Results for 1/2, 3/8, 5/16 and 1/4 in. Homogeneous Armor ’H’ Plates Welded with Austenitic Electrodes and Tested at Aberdeen Proving Ground during the Period of 1 April 1943 through 31 March 1944

    Science.gov (United States)

    1945-02-15

    Fitigibbons Boiler Company Jones & Laughlin Carnegie-Illinois Great Lakes Youngstown Harnischfeger Lincoln Electric 3^35 2 Florence Stove...t r- k XX ~1 ot> o rirl H tnx> • • HHO CO OH • • • lOOlO i-tOi^ o s O OlOO • • • • mc\\jc\\j CTN ITM-fX) o • • • » LPir

  6. Manual fire fighting tactics at Nuclear Power Plant

    International Nuclear Information System (INIS)

    Jee, Moon Hak; Moon, Chan Kook

    2012-01-01

    The general requirements of fire protection at nuclear power plant (NPP) are fire protection program, fire hazard analysis, and fire prevention features. In addition, specific fire protection requirements such as water supplies, fire detection, fire protection of safe related equipment, and safe shutdown capabilities must be provided. Particularly, manual fire fighting is required as specific requirements with the provisions to secure manual fire suppression, fire brigade and its training, and administrative controls for manual fire fighting. If a fire is alarmed and confirmed to be a real fire, the fire brigade must take manual fire fighting activities as requested at fire protection program. According to the present requirements in itself, there is not any specific manual fire fighting ways or practical strategies. In general, fire zones or compartments at NPPs are built in a confined condition. In theory, the fire condition will change from a combustible-controlled fire to a ventilation-governing fire with the time duration. In case of pool fire with the abundant oxygen and flammable liquid, it can take just a few minutes for the flash-over to occur. For the well-confined fire zone, it will change from a flame fire to a smoldering state before the entrance door is opened by the fire brigade. In this context, the manual fire fighting activities must be based on a quantitative analysis and a fire risk evaluation. At this paper, it was suggested that the fire zones at NPPs should be grouped on the inherent functions and fire characteristics. Based on the fire risk characteristics and the fire zone grouping, the manual fire fighting tactics are suggested as an advanced fire fighting solution

  7. ABCC publication manual

    Energy Technology Data Exchange (ETDEWEB)

    1959-01-01

    The reporting policy of the Atomic Bomb Casualty Commission is described in detail in this manual. Specific topics covered are: research project register; research publication policy; USA publication procedures; Japan publication procedures, report preparation instructions; and a glossary of institutions terms, phrases, and symbols. 15 figures. (DMC)

  8. NDS EXFOR Manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1979-06-01

    This manual contains the coding rules and formats and NDS internal compilation rules for the exchange format (EXFOR) for the transmission of nuclear reaction data between national and international nuclear data centres, and for the data storage and retrieval system of the IAEA Nuclear Data Section

  9. CANAL user's manual

    International Nuclear Information System (INIS)

    Faya, A.; Wolf, L.; Todreas, N.

    1979-11-01

    CANAL is a subchannel computer program for the steady-state and transient thermal hydraulic analysis of BWR fuel rod bundles. The purpose of this manual is to introduce the user into the mechanism of running the code by providing information about the input data and options

  10. AELIB user's manual

    International Nuclear Information System (INIS)

    Evans, L.E.; Klawitter, G.L.

    1981-05-01

    This report is an updatable manual for users of AELIB, the AECL Library of FORTRAN-callable routines for the CRNL CDC 6600/CYBER 170 system. It provides general advice on the use of this library and detailed information on the selection and usage of particular library routines

  11. Nuclear medicine. 1 part. Manual

    International Nuclear Information System (INIS)

    Shlygina, O.E.; Borisenko, A.R.

    2006-01-01

    Current manual is urged to give wide-scale readers a submission on a key principles and methods of nuclear medicine, and it opportunities and restrictions in diagnostics and treatment of different diseases. Nuclear medicine is differing first of all by combination of diverse knowledge fields: special knowledge of a doctor, knowledge of physical processes bases, related with radiation, grounds of radiopharmaceutics, dosimetry. In the base of the book the 5th edition of 'Nuclear medicine' manual in 2 parts of German authors - Schicha, G.; Schober, O. is applied. In the book publishing the stuff of the Institute of Nuclear Physics of the National Nuclear Center of Republic of Kazakhstan has been worked. Modifications undergo practically all chapters: especially the second one, forth and sixth was enlarged. The 1 part of the book was published due to support of IAEA within the Technical cooperation project 'Implementation of Nuclear Medicine and Biophysics Center' (KAZ/6/007). The manual second part - devoted to applications of nuclear medicine methods for diagnostics and treatment - will be published in 2007

  12. Operator's Manual for SHEBA Powered Tether Balloon System

    Science.gov (United States)

    Lappen, Cara-Lyn; Randall, David A.

    1998-01-01

    The Surface Heat and Energy Budget of the Arctic (SHEBA) was an intensive field project which took place in the Arctic Ocean from October 1997 through October 1998. Its purpose was to measure as many facets of the Arctic environment as possible so that we would be able to better understand the interaction between the ice, atmosphere, and ocean and their interactions with global climate. One aspect of the atmospheric field component was launching tethered balloons to monitor the profiles of temperature, wind, pressure, and humidity, as well as examine the vertical structure of cloud droplet sizes and distributions. The tethered balloon that we used was one specially designed for use in freezing climates by SPEC Corporation in Boulder, Colorado. A special winch that was able to withstand Arctic temperature and weather became necessary when the testing of simple winch systems used in warmer climates failed under these extreme conditions. The purpose of this manual is to acquaint any new user to the powered tethered balloon system deployed at the The Surface Heat and Energy Budget of the Arctic (SHEBA ice camp. It includes a description of the preparations necessary to get ready for a launch, the mechanics of the actual launch, and an account of the proper procedure for taking down the equipment when finished. It will also include tips on how to minimize potential equipment failures, some trouble shooting, and some safety ideas. This manual is designed so that new operators can use the system with minimal previous training. At the end of this manual, the reader will find a quick checklist.

  13. Manual Dexterity in Schizophrenia—A Neglected Clinical Marker?

    Directory of Open Access Journals (Sweden)

    Maxime Térémetz

    2017-07-01

    Full Text Available Impaired manual dexterity is commonly observed in schizophrenia. However, a quantitative description of key sensorimotor components contributing to impaired dexterity is lacking. Whether the key components of dexterity are differentially affected and how they relate to clinical characteristics also remains unclear. We quantified the degree of dexterity in 35 stabilized patients with schizophrenia and in 20 age-matched control subjects using four visuomotor tasks: (i force tracking to quantify visuomotor precision, (ii sequential finger tapping to measure motor sequence recall, (iii single-finger tapping to assess temporal regularity, and (iv multi-finger tapping to measure independence of finger movements. Diverse clinical and neuropsychological tests were also applied. A patient subgroup (N = 15 participated in a 14-week cognitive remediation protocol and was assessed before and after remediation. Compared to control subjects, patients with schizophrenia showed greater error in force tracking, poorer recall of tapping sequences, decreased tapping regularity, and reduced degree of finger individuation. A composite performance measure discriminated patients from controls with sensitivity = 0.79 and specificity = 0.9. Aside from force-tracking error, no other dexterity components correlated with antipsychotic medication. In patients, some dexterity components correlated with neurological soft signs, Positive and Negative Syndrome Scale (PANSS, or neuropsychological scores. This suggests differential cognitive contributions to these components. Cognitive remediation lead to significant improvement in PANSS, tracking error, and sequence recall (without change in medication. These findings show that multiple aspects of sensorimotor control contribute to impaired manual dexterity in schizophrenia. Only visuomotor precision was related to antipsychotic medication. Good diagnostic accuracy and responsiveness to treatment suggest that manual

  14. BBC users manual

    International Nuclear Information System (INIS)

    Ltterst, R.F.; Sutcliffe, W.G.; Warshaw, S.I.

    1977-11-01

    BBC is a two-dimensional, multifluid Eulerian hydro-radiation code based on KRAKEN and some subsequent ideas. It was developed in the explosion group in T-Division as a basic two-dimensional code to which various types of physics can be added. For this reason BBC is a FORTRAN (LRLTRAN) code. In order to gain the 2-to-1 to 4-to-1 speed advantage of the STACKLIB software on the 7600's and to be able to execute at high speed on the STAR, the vector extensions of LRLTRAN (STARTRAN) are used throughout the code. Either cylindrical- or slab-type problems can be run on BBC. The grid is bounded by a rectangular band of boundary zones. The interfaces between the regular and boundary zones can be selected to be either rigid or nonrigid. The setup for BBC problems is described in the KEG Manual and LEG Manual. The difference equations are described in BBC Hydrodynamics. Basic input and output for BBC are described

  15. Danglers in Patient Information Leaflets and Technical Manuals

    DEFF Research Database (Denmark)

    Køhler Simonsen, Henrik

    2014-01-01

    in fact been proved. The analysis and the discussion showed that dangling participles are not very frequent in PILs, but much more common in technical manuals. The data showed that there were no “ludicrous” danglers,(see Matthews and Matthews 2008:146), in PILcorp. However, the analysis showed that both......Dangling participles and other types of ambiguous or unclear sentence constructions in directive and informative medical and technical texts, such as patient information leaflets (PILs) and technical manuals, render instructions unclear and potentially dangerous for the layman reader, i......, and readability on the basis of two corpora: a corpus of PILs (PILcorp) and a corpus of technical manuals (TECHcorp). The hypothesis is that patient information leaflets will contain fewer dangling constructions than technical manuals because of the strict regulations on product information texts including PILs...

  16. Maintenance Personnel Performance Simulation (MAPPS) model. Users' Manual

    International Nuclear Information System (INIS)

    Kopstein, F.F.; Wolf, J.J.

    1985-09-01

    This report (MAPPS User's Manual) is the last report to be published from this program and provides detailed guidelines for utilization of the MAPPS model. Although the model has been developed to be highly user-friendly and provides interactive means for controlling and running of the model, the user's manual is provided as a guide for the user in the event clarification or direction is required. The user will find that in general the model requires primarily user input that is self explanatory. Once initial familiarization with the model has been achieved by the user, the amount of interaction between the user's manual and the computer model will be minimal. It is suggested however that even the experienced user keep the user's manual handy for quick reference. 5 refs., 10 figs., 7 tabs

  17. Deficits in Visuo-Motor Temporal Integration Impacts Manual Dexterity in Probable Developmental Coordination Disorder.

    Science.gov (United States)

    Nobusako, Satoshi; Sakai, Ayami; Tsujimoto, Taeko; Shuto, Takashi; Nishi, Yuki; Asano, Daiki; Furukawa, Emi; Zama, Takuro; Osumi, Michihiro; Shimada, Sotaro; Morioka, Shu; Nakai, Akio

    2018-01-01

    The neurological basis of developmental coordination disorder (DCD) is thought to be deficits in the internal model and mirror-neuron system (MNS) in the parietal lobe and cerebellum. However, it is not clear if the visuo-motor temporal integration in the internal model and automatic-imitation function in the MNS differs between children with DCD and those with typical development (TD). The current study aimed to investigate these differences. Using the manual dexterity test of the Movement Assessment Battery for Children (second edition), the participants were either assigned to the probable DCD (pDCD) group or TD group. The former was comprised of 29 children with clumsy manual dexterity, while the latter consisted of 42 children with normal manual dexterity. Visuo-motor temporal integration ability and automatic-imitation function were measured using the delayed visual feedback detection task and motor interference task, respectively. Further, the current study investigated whether autism-spectrum disorder (ASD) traits, attention-deficit hyperactivity disorder (ADHD) traits, and depressive symptoms differed among the two groups, since these symptoms are frequent comorbidities of DCD. In addition, correlation and multiple regression analyses were performed to extract factors affecting clumsy manual dexterity. In the results, the delay-detection threshold (DDT) and steepness of the delay-detection probability curve, which indicated visuo-motor temporal integration ability, were significantly prolonged and decreased, respectively, in children with pDCD. The interference effect, which indicated automatic-imitation function, was also significantly reduced in this group. These results highlighted that children with clumsy manual dexterity have deficits in visuo-motor temporal integration and automatic-imitation function. There was a significant correlation between manual dexterity, and measures of visuo-motor temporal integration, and ASD traits and ADHD traits and

  18. The organizational measurement manual

    National Research Council Canada - National Science Library

    Wealleans, David

    2001-01-01

    ... Relationship of process to strategic measurements Summary 37 36Contents 19/10/2000 1:23 pm Page vi vi THE ORGANIZATIONAL MEASUREMENT MANUAL 4 PART 2 ESTABLISHING A PROCESS MEASUREMENT PROGRAMME...

  19. In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening

    Science.gov (United States)

    Demircan, Sabit; Cene, Erhan; Aya, Serhan Aydın; Erdem, Mehmet Ali; Cankaya, Abdulkadir Burak

    2017-01-01

    Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload. PMID:28473988

  20. Contents Development of Library Signage Manual in Korea

    OpenAIRE

    In-Ja Ahn

    2011-01-01

    There is an increase in the need of an unified manual for library signage system, due to recent increase in library construction or remodeling. This paper, therefore, can be a basic research to develop library signage system manual. Based on an anual released from KLA and the sum of opinions of expert groups, this research proposes a concrete list of contents for library signage system manual as follows. First, there is a need of theoretical basis of library signage system. Second, for the ac...

  1. Droid X The Missing Manual

    CERN Document Server

    Gralla, Preston

    2011-01-01

    Get the most from your Droid X right away with this entertaining Missing Manual. Veteran tech author Preston Gralla offers a guided tour of every feature, with lots of expert tips and tricks along the way. You'll learn how to use calling and texting features, take and share photos, enjoy streaming music and video, and much more. Packed with full-color illustrations, this engaging book covers everything from getting started to advanced features and troubleshooting. Unleash the power of Motorola's hot new device with Droid X: The Missing Manual. Get organized. Import your contacts and sync wit

  2. Configuration and supervision of advanced distributed data acquisition and processing systems for long pulse experiments using JINI technology

    International Nuclear Information System (INIS)

    Gonzalez, Joaquin; Ruiz, Mariano; Barrera, Eduardo; Lopez, Juan Manuel; de Arcas, Guillermo; Vega, Jesus

    2009-01-01

    The development of tools for managing the capabilities and functionalities of distributed data acquisition systems is essential in long pulse fusion experiments. The intelligent test and measurement system (ITMS) developed by UPM and CIEMAT is a technology that permits implementation of a scalable data acquisition and processing system based on PXI or CompactPCI hardware. Several applications based on JINI technology have been developed to enable use of this platform for extensive implementation of distributed data acquisition and processing systems. JINI provides a framework for developing service-oriented, distributed applications. The applications are based on the paradigm of a JINI federation that supports mechanisms for publication, discovering, subscription, and links to remote services. The model we implemented in the ITMS platform included services in the system CPU (SCPU) and peripheral CPUs (PCPUs). The resulting system demonstrated the following capabilities: (1) setup of the data acquisition and processing to apply to the signals, (2) information about the evolution of the data acquisition, (3) information about the applied data processing and (4) detection and distribution of the events detected by the ITMS software applications. With this approach, software applications running on the ITMS platform can be understood, from the perspective of their implementation details, as a set of dynamic, accessible, and transparent services. The search for services is performed using the publication and subscription mechanisms of the JINI specification. The configuration and supervision applications were developed using remotely accessible (LAN or WAN) objects. The consequence of this approach is a hardware and software architecture that provides a transparent model of remote configuration and supervision, and thereby a means to simplify the implementation of a distributed data acquisition system with scalable and dynamic local processing capability developed in a

  3. Configuration and supervision of advanced distributed data acquisition and processing systems for long pulse experiments using JINI technology

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Joaquin; Ruiz, Mariano [Grupo de Investigacion en Instrumentacion y Acustica Aplicada, Universidad Politecnica de Madrid (UPM), Ctra. Valencia Km-7, 28031, Madrid (Spain); Barrera, Eduardo [Grupo de Investigacion en Instrumentacion y Acustica Aplicada, Universidad Politecnica de Madrid (UPM), Ctra. Valencia Km-7, 28031, Madrid (Spain)], E-mail: eduardo.barrera@upm.es; Lopez, Juan Manuel; de Arcas, Guillermo [Grupo de Investigacion en Instrumentacion y Acustica Aplicada, Universidad Politecnica de Madrid (UPM), Ctra. Valencia Km-7, 28031, Madrid (Spain); Vega, Jesus [Asociacion EURATOM/CIEMAT para Fusion, Avda. Complutense 22, 28040, Madrid (Spain)

    2009-06-15

    The development of tools for managing the capabilities and functionalities of distributed data acquisition systems is essential in long pulse fusion experiments. The intelligent test and measurement system (ITMS) developed by UPM and CIEMAT is a technology that permits implementation of a scalable data acquisition and processing system based on PXI or CompactPCI hardware. Several applications based on JINI technology have been developed to enable use of this platform for extensive implementation of distributed data acquisition and processing systems. JINI provides a framework for developing service-oriented, distributed applications. The applications are based on the paradigm of a JINI federation that supports mechanisms for publication, discovering, subscription, and links to remote services. The model we implemented in the ITMS platform included services in the system CPU (SCPU) and peripheral CPUs (PCPUs). The resulting system demonstrated the following capabilities: (1) setup of the data acquisition and processing to apply to the signals, (2) information about the evolution of the data acquisition, (3) information about the applied data processing and (4) detection and distribution of the events detected by the ITMS software applications. With this approach, software applications running on the ITMS platform can be understood, from the perspective of their implementation details, as a set of dynamic, accessible, and transparent services. The search for services is performed using the publication and subscription mechanisms of the JINI specification. The configuration and supervision applications were developed using remotely accessible (LAN or WAN) objects. The consequence of this approach is a hardware and software architecture that provides a transparent model of remote configuration and supervision, and thereby a means to simplify the implementation of a distributed data acquisition system with scalable and dynamic local processing capability developed in a

  4. Digital logic circuit test

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Gil Jung; Yang, Hong Young

    2011-03-15

    This book is about digital logic circuit test, which lists the digital basic theory, basic gate like and, or And Not gate, NAND/NOR gate such as NAND gate, NOR gate, AND and OR, logic function, EX-OR gate, adder and subtractor, decoder and encoder, multiplexer, demultiplexer, flip-flop, counter such as up/down counter modulus N counter and Reset type counter, shift register, D/A and A/D converter and two supplements list of using components and TTL manual and CMOS manual.

  5. Cuerpo de Paz Manual de Sistema de Programacion y Capacitacion (Peace Corps Programming and Training System Manual): T0063.

    Science.gov (United States)

    Peace Corps, Washington, DC.

    This Spanish version of the Peace Corps Programming and Training System Manual is designed to help field staff members of the Peace Corps train volunteers. Its task descriptions, guidelines, examples, and definitions are intended to be practical and informative rather than restrictive. The manual is divided into six major sections: (1)…

  6. NCDC Archive Documentation Manuals

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The National Climatic Data Center Tape Deck Documentation library is a collection of over 400 manuals describing NCDC's digital holdings (both historic and current)....

  7. The stormwater management manual for Malaysia

    International Nuclear Information System (INIS)

    Md Nasir Md Noh

    2006-01-01

    The government of Malaysia considers land and water as two very important natural resources. Consequently, the conservation practice of these natural resources remain top priority agenda with various laws and policies apart from manuals and guidelines available for practitioners to follow right from planning, design and implementation stages. Among the laws and regulations are national land code, land conservation act, local government act, street, drainage and building act, town and country planning act, and environmental quality act among others. In addition, stormwater management manual for Malaysia developed by department of irrigation and drainage, guidelines on the prevention and control of soil erosion and siltation in Malaysia developed by department of environment, standard specification for road works established by public works department, use of flood detention ponds as part of open space set up by department of town and country planning, and guideline for agricultural development at slope terrain published by department of agriculture are some of the established manuals and guidelines utilized around the country. The stormwater management manual for malaysia (msma) is the latest of the series of guidelines available in the country for inculcating up to date stormwater management apart from ensuring sustainable soil and water conservation practice in Malaysia. This manual has been published in 2000 and started to be utilized since 1 January 2001. Ever since msma has been widely used for the planning, design and implementation of various land development activities in the country. Among the key points highlighted in this manual are water quantity control and water quality control. Water quantity control focuses on the flash flood control technique due to the increase rate of water flowing out of developed areas while water quality control meant for the controlled of non-point source pollution generated by developed areas by contemplating on the best

  8. The underwater coincidence counter for plutonium measurements in mixed-oxide fuel assemblies manual

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Menlove, H.O.; Abhold, M.; Baker, M.; Pecos, J.

    1999-01-01

    This manual describes the Underwater Coincidence Counter (UWCC) that has been designed for the measurement of plutonium in mixed-oxide (MOX) fuel assemblies prior to irradiation. The UWCC uses high-efficiency 3 He neutron detectors to measure the spontaneous-fission and induced-fission rates in the fuel assembly. Measurements can be made on MOX fuel assemblies in air or underwater. The neutron counting rate is analyzed for singles, doubles, and triples time correlations to determine the 240 Pu effective mass per unit length of the fuel assembly. The system can verify the plutonium loading per unit length to a precision of less than 1% in a measurement time of 2 to 3 minutes. System design, components, performance tests, and operational characteristics are described in this manual

  9. How crawling and manual object exploration are related to the mental rotation abilities of 9-month-old infants

    Directory of Open Access Journals (Sweden)

    Gudrun eSchwarzer

    2013-03-01

    Full Text Available The present experiment examined whether the mental rotation ability of 9-month-old infants was related to their abilities to crawl and manually explore objects. Forty-eight 9-month-old infants were tested; half of them had been crawling for an average of 9.3 weeks. The infants were habituated to a video of a simplified Shepard-Metzler object rotating back and forth through a 240° angle around the longitudinal axis of the object. They were tested with videos of the same object rotating through a previously unseen 120° angle and with a mirror image of the display. All of the infants also participated in a manual object exploration task, in which they freely explored 5 toy blocks. The results showed that the crawlers looked significantly longer at the novel (mirror object than at the familiar object, independent of their manual exploration scores. The non-crawlers looking times, in contrast, were influenced by the manual exploration scores. The infants who did not spontaneously explore the toy blocks tended to show a familiarity preference, whereas those who explored the toy blocks preferred to look at the novel object. Thus, all of the infants were able to master the mental rotation task but it seemed to be the most complex process for infants who had no crawling experience and who did not spontaneously explore objects.

  10. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  11. Matematica 3. Manual.

    Science.gov (United States)

    D'Alu, Maria Jose Miranda de Sousa

    This teachers manual accompanies a mathematics textbook, written in Portuguese, for third graders. It closely follows the objectives and methodology of the major curricula used throughout the schools in the United States. The 11 chapters deal with: numeration (0-999,999); addition with and without regrouping; subtraction with and without…

  12. Tokai densitometer manual

    International Nuclear Information System (INIS)

    Sprinkle, J.K. Jr.; Hsue, S.T.; Junck, K.

    1987-01-01

    In 1979, the Tokai densitometer was installed at the Tokai Reprocessing Plant in Tokai, Japan. It uses a nondestructive active technique (K-edge absorption densitometry) to assay solutions for plutonium content. The original hardware was upgraded in 1984 and 1985. This manual describes the instrument's operation after the upgrade. 2 refs

  13. Micro-segmental hair analysis for proving drug-facilitated crimes: Evidence that a victim ingested a sleeping aid, diphenhydramine, on a specific day.

    Science.gov (United States)

    Kuwayama, Kenji; Nariai, Maika; Miyaguchi, Hajime; Iwata, Yuko T; Kanamori, Tatsuyuki; Tsujikawa, Kenji; Yamamuro, Tadashi; Segawa, Hiroki; Abe, Hiroko; Iwase, Hirotaro; Inoue, Hiroyuki

    2018-07-01

    Sleeping aids are often abused in the commission of drug-facilitated crimes. Generally, there is little evidence that a victim ingested a spiked drink unknowingly because the unconscious victim cannot report the situation to the police immediately after the crime occurred. Although conventional segmental hair analysis can estimate the number of months since a targeted drug was ingested, this analysis cannot determine the specific day of ingestion. We recently developed a method of micro-segmental hair analysis using internal temporal markers (ITMs) to estimate the day of drug ingestion. This method was based on volunteer ingestion of ITMs to determine a timescale within individual hair strands, by segmenting a single hair strand at 0.4-mm intervals, corresponding to daily hair growth. This study assessed the ability of this method to estimate the day of ingestion of an over-the-counter sleeping aid, diphenhydramine, which can be easily abused. To model ingestion of a diphenhydramine-spiked drink unknowingly, each subject ingested a dose of diphenhydramine, followed by ingestion of two doses of the ITM, chlorpheniramine, 14days apart. Several hair strands were collected from each subject's scalp several weeks after the second ITM ingestion. Diphenhydramine and ITM were detected at specific regions within individual hair strands. The day of diphenhydramine ingestion was estimated from the distances between the regions and the days of ITM ingestion. The error between estimated and actual ingestion day ranged from -0.1 to 1.9days regardless of subjects and hair collection times. The total time required for micro-segmental analysis of 96 hair segments (hair length: 3.84cm) was approximately 2days and the cost was almost the same as in general drug analysis. This procedure may be applicable to the investigation of crimes facilitated by various drugs. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Los Alamos waste drum shufflers users manual

    International Nuclear Information System (INIS)

    Rinard, P.M.; Adams, E.L.; Painter, J.

    1993-01-01

    This user manual describes the Los Alamos waste drum shufflers. The primary purpose of the instruments is to assay the mass of 235 U (or other fissile materials) in drums of assorted waste. It can perform passive assays for isotopes that spontaneously emit neutrons or active assays using the shuffler technique as described on this manual

  15. New Mexico Response to Intervention Framework Manual

    Science.gov (United States)

    New Mexico Public Education Department, 2014

    2014-01-01

    This manual details the instructional framework and guidance on the Response to Intervention (RtI) process in New Mexico. The manual includes: (1) a section on each of the three instructional tiers; (2) a glossary of key terms; (3) sample forms to assist with the Student Assistance Team (SAT) process; and (4) key resources for teachers.

  16. CORRELATIONS BETWEEN FINDINGS OF OCCLUSAL AND MANUAL ANALYSIS IN TMD-PATIENTS

    Directory of Open Access Journals (Sweden)

    Mariana Dimova

    2016-08-01

    Full Text Available The aim of this study was to investigate and analyze the possible correlations between findings by manual functional analysis and clinical occlusal analysis in TMD-patients. Material and methods: Material of this study are 111 TMD-patients selected after visual diagnostics, functional brief review under Ahlers Jakstatt, intraoral examination and taking periodontal status. In the period September 2014 - March 2016 all patients were subjected to manual functional analysis and clinical occlusal analysis. 17 people (10 women and 7 men underwent imaging with cone-beam computed tomography. Results: There were found many statistically significant correlations between tests of the structural analysis that indicate the relationships between findings. Conclusion: The presence of statistically significant correlations between occlusal relationships, freedom in the centric and condition of the muscle complex of masticatory system and TMJ confirm the relationship between the state of occlusal components and TMD.

  17. Developing and Testing Twelve-Step Facilitation for Adolescents with Substance Use Disorder: Manual Development and Preliminary Outcomes

    Directory of Open Access Journals (Sweden)

    John F. Kelly

    2016-01-01

    Full Text Available Adolescent substance use disorder treatment programs are often based on the 12-step philosophy of Alcoholics Anonymous and/or link adolescents to these free resources. Despite this, no studies have developed and rigorously tested a twelve-step facilitation (TSF intervention for young people, leaving a significant evidence gap. This study describes the first systematic development of an outpatient adolescent TSF treatment. An integrated twelve-step facilitation (iTSF treatment incorporated TSF, motivational enhancement therapy, and cognitive behavioral therapy elements and was developed in an iterative manner with weekly feedback provided by 36 adolescents ( M age 17 years [SD = 1.4]; 52.8% white with DSM-IV substance use disorder recruited from the community. Assessments were conducted at baseline and at three and six months. Participants completed 6 of 10 sessions on average (8 participants completed all 10. Notable treatment developments were the inclusion of “in-services” led by Marijuana Anonymous members, including parents in a portion of individual sessions to provide a rationale for TSF, and use of a Socratic therapeutic interaction style. Acceptability and feasibility of the treatment were excellent (treatment satisfaction was 4.29 [SD = 0.59] out of 5. In keeping with TSF theory, the intervention substantially increased 12-step participation, and greater participation related to greater abstinence. iTSF is a replicable manualized treatment that can be implemented and tested in outpatient settings. Given the widespread compatibility of iTSF with the current adolescent treatment, if found efficacious, iTSF could be relatively easily adopted, implemented, and sustained and could provide an evidence-based option that could undergird current practice.

  18. 39 CFR 20.3 - Availability of the International Mail Manual.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Availability of the International Mail Manual. 20.3 Section 20.3 Postal Service UNITED STATES POSTAL SERVICE INTERNATIONAL MAIL INTERNATIONAL POSTAL SERVICE § 20.3 Availability of the International Mail Manual. Copies of the International Mail Manual may...

  19. Manual accuracy in comparison with a miniature master slave device--preclinical evaluation for ear surgery.

    Science.gov (United States)

    Runge, A; Hofer, M; Dittrich, E; Neumuth, T; Haase, R; Strauss, M; Dietz, A; Lüth, T; Strauss, G

    2011-01-01

    Manual accuracy in microsurgery is reduced by tremor and limited access. A surgical approach through the middle ear also puts delicate structures at risk, while the surgeon is often working at an unergonomic position. At this point a micromanipulator could have a positive influence. A system was developed to measure "working accuracy", time and precision during manipulation in the middle ear. 10 ENT-surgeons simulated a perforation of the stapedial footplate on a modified 3D print of a human skull in a mock OR. Each trial was repeated more than 200 times aiming manually and using a micro-manipulator. Data of over 4000 measurements was tested and graphically processed. Work strain was evaluated with a questionnaire. Accuracy for manual and micromanipulator perforation revealed a small difference. Learning curves showed a stronger decrease both in deviation and time when the micromanipulator was used. Also a lower work strain was apparent. The micromanipulator has the potential as an aiding device in ear surgery.

  20. Quality manual for Laboratories of the Nuclear Materials Characterization Division

    International Nuclear Information System (INIS)

    Sabato, S.F.

    1991-05-01

    This publication presents the first Quality Manual for the Laboratories at the Nuclear Materials Characterization Division. The Manual describes the laboratories, its organization structure, fields of activities, personnel records, equipments, maintenance and calibration. The main aspects concerning quality assurance in the analysis were discussed. The whole system of receiving, identifying and processing analysis of the samples is shown. Since there are many information to be contained in several subjects of the Quality Manual, there were produced separate documents that are cross referenced in the manual. (author)