WorldWideScience

Sample records for testing activity

  1. Automating Test Activities: Test Cases Creation, Test Execution, and Test Reporting with Multiple Test Automation Tools

    OpenAIRE

    Loke Mun Sei

    2015-01-01

    Software testing has become a mandatory process in assuring the software product quality. Hence, test management is needed in order to manage the test activities conducted in the software test life cycle. This paper discusses on the challenges faced in the software test life cycle, and how the test processes and test activities, mainly on test cases creation, test execution, and test reporting is being managed and automated using several test automation tools, i.e. Jira, ...

  2. TESTING TESTS ON ACTIVE GALACTIC NUCLEI MICROVARIABILITY

    International Nuclear Information System (INIS)

    De Diego, Jose A.

    2010-01-01

    Literature on optical and infrared microvariability in active galactic nuclei (AGNs) reflects a diversity of statistical tests and strategies to detect tiny variations in the light curves of these sources. Comparison between the results obtained using different methodologies is difficult, and the pros and cons of each statistical method are often badly understood or even ignored. Even worse, improperly tested methodologies are becoming more and more common, and biased results may be misleading with regard to the origin of the AGN microvariability. This paper intends to point future research on AGN microvariability toward the use of powerful and well-tested statistical methodologies, providing a reference for choosing the best strategy to obtain unbiased results. Light curves monitoring has been simulated for quasars and for reference and comparison stars. Changes for the quasar light curves include both Gaussian fluctuations and linear variations. Simulated light curves have been analyzed using χ 2 tests, F tests for variances, one-way analyses of variance and C-statistics. Statistical Type I and Type II errors, which indicate the robustness and the power of the tests, have been obtained in each case. One-way analyses of variance and χ 2 prove to be powerful and robust estimators for microvariations, while the C-statistic is not a reliable methodology and its use should be avoided.

  3. Basophil-activation tests in hymenoptera allergy

    NARCIS (Netherlands)

    Dubois, Anthony E. J.; van der Heide, Sicco

    The measurement of basophil-activation markers may be useful in detecting IgIE-mediated sensitization but the relevance for application of the basophil-activation test in prediction of clinical reactivity in Hymenoptera allergy is very limited. For this reason, this test currently has no established

  4. Electrolysis activities at FCH Test Center

    DEFF Research Database (Denmark)

    Ravn Nielsen, Eva; Nygaard, Frederik Berg

    FCH Test Center for fuel cell and hydrogen technologies was established in 2010 at Risø DTU in Denmark. Today, the test center is part of DTU Energy Conversion. The center gives industry access to advanced testing and demonstration of components and systems. A number of national projects and EU...... projects regarding water electrolysis involve FCH Test Center as a partner. This presentation gives an overview of the activities....

  5. Buildings, fields of activity, testing facilities

    International Nuclear Information System (INIS)

    1974-01-01

    Since 1969 the activities of the Materialpruefungsanstalt Stuttgart (MPA) have grown quickly as planned, especially in the field of reactor safety research, which made it necessary to increase the staff to approximately 165 members, to supplement the machines and equipment and to extend the fields of activities occasioning a further departmental reorganization. At present the MPA has the following departments: 1. Teaching (materials testing, materials science and strength of materials) 2. Materials and Welding Technology 3. Materials Science and General Materials Testing with Tribology 4. Design and Strength 5. Creep and Fatigue Testing 6. Central Facilities 7. Vessel and Component Testing. (orig./RW) [de

  6. Toxicity tests, antioxidant activity, and antimicrobial activity of chitosan

    Science.gov (United States)

    Kurniasih, M.; Purwati; Dewi, R. S.

    2018-04-01

    Chitosan is a naturally occurring cationic biopolymer, obtained by alkaline deacetylation of chitin. This research aims to investigate the toxicity, antioxidant activity and antibacterial activity of chitosan from shrimp chitin. In this study, chitin extracted from shrimp waste material. Chitin is then deacetylation with 60% NaOH so that chitosan produced. Degrees of deacetylation, molecular weight, toxicity test, antioxidant activity and antimicrobial activity of chitosan then evaluated. Toxicity test using Brine Shrimp Lethality Test. The antioxidant analysis was performed using DPPH method (2, 2-diphenyl-1-picrylhydrazyl) and FTC method (ferric thiocyanate) in which the radical formed will reduce Ferro to Ferri resulting in a complex with thiocyanate. To determine the antibacterial activity of Staphylococcus aureus, antifungal in Candida albicans and Aspergillus niger by measuring antimicrobial effects and minimum inhibitory concentrations (MIC). Based on the result of research, the value of degrees of deacetylation, molecular weight, and LC50 values of chitosan synthesis was 94,32, 1052.93 g/mol and 1364.41 ppm, respectively. In general, the antioxidative activities increased as the concentration of chitosan increased. MIC value of chitosan against S. aureus, C. albicans, and A. niger was 10 ppm, 15.6 ppm, and 5 ppm, respectively.

  7. ACT listening test[Active transducers

    Energy Technology Data Exchange (ETDEWEB)

    Agerkvist, F. [Oersted, DTU, Kgs. Lyngby (Denmark); Fenger, L.M. [Bang and Olufsen ICEPower a/s, Kgs. Lyngby (Denmark)

    2004-07-01

    This report describes the series of subjective listening that was performed in order to test the subjective quality of the integration of amplifier and loudspeaker developed in the Active transducer project. The project is a fundamental study of the loss mechanisms in loudspeakers and amplifiers. The project has resulted in new switch mode amplifier topologies with very high audio performance at a very low cost. (BA)

  8. Test Blanket Working Group's recent activities

    International Nuclear Information System (INIS)

    Vetter, J.E.

    2001-01-01

    The ITER Test Blanket Working Group (TBWG) has continued its activities during the period of extension of the EDA with a revised charter on the co-ordination of the development work performed by the Parties and by the JCT leading to a co-ordinated test programme on ITER for a DEMO-relevant tritium breeding blanket. This follows earlier work carried out until July 1998, which formed part of the ITER Final Design Report (FDR), completed in 1998. Whilst the machine parameters for ITER-FEAT have been significantly revised compared to the FDR, testing of breeding blanket modules remains a main objective of the test programme and the development of a reactor-relevant breeding blanket to ensure tritium fuel self-sufficiency is recognized a key issue for fusion. Design work and R and D on breeding blanket concepts, including co-operation with the other Contacting Parties of the ITER-EDA for testing these concepts in ITER, are included in the work plans of the Parties

  9. F-15B ACTIVE test stand

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the underside of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the thrust stand being used for ground testing of a new thrust-vectoring concept. The twin-engine F-15 research aircraft is equipped with new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. They give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. Ground testing during the first two weeks of November 1995 went well, and flight tests began in March 1996. These tests could result in significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace.

  10. Tests on 'radio-active' material

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The storage of radio-active waste from nuclear power stations is a well known problem and a subject for extensive investigation. In connection with the use of cement as storage material, tests were carried out on cement-filled 200-litre sheet-steel containers. In order to avoid contamination of the cement core by drilling sludge, any drilling operation must be carried out dry, i.e. without liquid cooling. Air-blast cooling was therefore used for the cooling of a diamond drill and also for the removal of swarf. (H.E.G.)

  11. Testing activities at the National Battery Test Laboratory

    Science.gov (United States)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  12. Temelin 1000 MW Units active testing stage - commissioning experience

    International Nuclear Information System (INIS)

    Ubra, O.; Riha, V.

    2003-01-01

    There were three basic stages of the NPP Temelin Units active testing stage- The zero and low power testing, The power ascension testing and Plant Performance Test. The main objective of the start- up process stages and the testing procedures including some operational experience are described in the paper. (author)

  13. Active Waste Materials Corrosion and Decontamination Tests

    International Nuclear Information System (INIS)

    Danielson, M.J.; Elmore, M.R.; Pitman, S.G.

    2000-01-01

    Stainless steel alloys, 304L and 316L, were corrosion tested in representative radioactive samples of three actual Hanford tank waste solutions (Tanks AW-101, C-104, AN-107). Both the 304L and 316L exhibited good corrosion performance when immersed in boiling waste solutions. The maximum general corrosion rate was 0.015 mm/y (0.60 mils per year). Generally, the 304L had a slightly higher rate than the 316L. No localized attack was observed after 122 days of testing in the liquid phase, liquid/vapor phase, or vapor phase. Radioactive plate-out decontamination tests indicated that a 24-hour exposure to 1 und M HNO 3 could remove about 99% of the radioactive components in the metal film when exposed to the C-104 and AN-107 solutions. The decontamination results are less certain for the AW-101 solution, since the initial contamination readings exceeded the capacity of the meter used for this test

  14. Active fault diagnosis based on stochastic tests

    DEFF Research Database (Denmark)

    Poulsen, Niels Kjølstad; Niemann, Hans Henrik

    2008-01-01

    The focus of this paper is on stochastic change detection applied in connection with active fault diagnosis (AFD). An auxiliary input signal is applied in AFD. This signal injection in the system will in general allow us to obtain a fast change detection/isolation by considering the output...

  15. Recovery Efficiency Test Project: Phase 1, Activity report

    Energy Technology Data Exchange (ETDEWEB)

    Overbey, W.K. Jr.; Wilkins, D.W.; Keltch, B.; Saradji, B.; Salamy, S.P.

    1988-04-01

    This report is the second volume of the Recovery Efficiency Test Phase I Report of Activities. Volume 1 covered selection, well planning, drilling, coring, logging and completion operations. This volume reports on well testing activities, reclamation activities on the drilling site and access roads, and the results of physical and mechanical properties tests on the oriented core material obtained from a horizontal section of the well. 3 refs., 21 figs., 10 tabs.

  16. Severe Accident Test Station Activity Report

    Energy Technology Data Exchange (ETDEWEB)

    Pint, Bruce A [ORNL; Terrani, Kurt A [ORNL

    2015-06-01

    Enhancing safety margins in light water reactor (LWR) severe accidents is currently the focus of a number of international R&D programs. The current UO2/Zr-based alloy fuel system is particularly susceptible since the Zr-based cladding experiences rapid oxidation kinetics in steam at elevated temperatures. Therefore, alternative cladding materials that offer slower oxidation kinetics and a smaller enthalpy of oxidation can significantly reduce the rate of heat and hydrogen generation in the core during a coolant-limited severe accident. In the U.S. program, the high temperature steam oxidation performance of accident tolerant fuel (ATF) cladding solutions has been evaluated in the Severe Accident Test Station (SATS) at Oak Ridge National Laboratory (ORNL) since 2012. This report summarizes the capabilities of the SATS and provides an overview of the oxidation kinetics of several candidate cladding materials. A suggested baseline for evaluating ATF candidates is a two order of magnitude reduction in the steam oxidation resistance above 1000ºC compared to Zr-based alloys. The ATF candidates are categorized based on the protective external oxide or scale that forms during exposure to steam at high temperature: chromia, alumina, and silica. Comparisons are made to literature and SATS data for Zr-based alloys and other less-protective materials.

  17. Tritium activities in selected wells on the Nevada Test Site

    International Nuclear Information System (INIS)

    Lyles, B.F.

    1993-05-01

    Literature and data were reviewed related to radionuclides in groundwater on and near the Nevada Test Site. No elevated tritium activities have been reported outside of the major testing regions of the Nevada Test Site. Three wells were identified as having water with above-background (>50 pCi/l) tritium activities: UE-15d Water Well; USGS Water Well A; and USGS Test Well B Ex. Although none of these wells have tritium activities greater than the Nevada State Drinking Water standard (20,000 pCi/l), their time-series tritium trends may be indicative to potential on-site radionuclide migration

  18. Quality checking task force destructive testing of active waste forms

    International Nuclear Information System (INIS)

    James, J.M.; Smith, D.L.

    1987-03-01

    The implications of sampling and testing of full size active packages of intermediate level wastes are summarised in this report. Sampling operations are technically feasible but a major difficulty will be the disposal of secondary waste. A literature survey indicated that destructive testing of wasteforms is not carried out as a routine operation in Europe or the USA. (author)

  19. Effects of Vigorous Intensity Physical Activity on Mathematics Test Performance

    Science.gov (United States)

    Phillips, David S.; Hannon, James C.; Castelli, Darla M.

    2015-01-01

    The effect of an acute bout of physical activity on academic performance in school-based settings is under researched. The purpose of this study was to examine associations between a single, vigorous (70-85%) bout of physical activity completed during physical education on standardized mathematics test performance among 72, eighth grade students…

  20. Physical Activity and Cervical Cancer Testing among American Indian Women

    Science.gov (United States)

    Muus, Kyle J.; Baker-Demaray, Twyla B.; Bogart, T. Andy; Duncan, Glen E.; Jacobsen, Clemma; Buchwald, Dedra S.; Henderson, Jeffrey A.

    2012-01-01

    Purpose: Studies have shown that women who engage in high levels of physical activity have higher rates of cancer screening, including Papanicalaou (Pap) tests. Because American Indian (AI) women are at high risk for cervical cancer morbidity and mortality, we examined Pap screening prevalence and assessed whether physical activity was associated…

  1. Dissolution test for low-activity waste product acceptance

    International Nuclear Information System (INIS)

    Ebert, W. L.

    1998-01-01

    We have measured the mean and standard deviation of the solution concentrations of B, Na, and Si attained in replicate dissolution tests conducted at temperatures of 20, 40, and 70 C, for durations of 3 and 7 days, and at glass/water mass ratios of 1:10 and 1:1. These and other tests were conducted to evaluate the adequacy of the test methods specified in privatization contracts and to develop a data base that can be used to evaluate the reliability of reported results for tests performed on the waste products. Tests were conducted with a glass that we formulated to be similar to low-activity waste products that will be produced during the remediation of Hanford tank wastes. Statistical analyses indicated that, while the mean concentrations of B, Na, and Si were affected by the values of test parameters, the standard deviation of replicate tests was not. The precision of the tests was determined primarily by uncertainties in the analysis of the test solutions. Replicate measurements of other glass properties that must be reported for Hanford low-activity waste products were measured to evaluate the possible adoption of the glass used in these tests as a standard test material for the product acceptance process

  2. Active Protection of an MgB2 Test Coil

    Science.gov (United States)

    Park, Dong Keun; Hahn, Seungyong; Bascuñán, Juan; Iwasa, Yukikazu

    2011-01-01

    This paper presents results of a study, experimental and computational, of a detect-and-activate-the-heater protection technique applied to a magnesium diboride (MgB2) test coil operated in semi-persistent mode. The test coil with a winding ID of 25 cm and wound with ~500-m long reacted MgB2 wire was operated at 4.2 K immersed in a bath of liquid helium. In this active technique, upon the initiation of a “hot spot” of a length ~10 cm, induced by a “quench heater,” a “protection heater” (PH) of ~600-cm long planted within the test coil is activated. The normal zone created by the PH is large enough to absorb the test coil’s entire initial stored energy and still keeps the peak temperature within the winding below ~260 K. PMID:22081754

  3. Methanogenic activity tests by Infrared Tunable Diode Laser Absorption Spectroscopy.

    Science.gov (United States)

    Martinez-Cruz, Karla; Sepulveda-Jauregui, Armando; Escobar-Orozco, Nayeli; Thalasso, Frederic

    2012-10-01

    Methanogenic activity (MA) tests are commonly carried out to estimate the capability of anaerobic biomass to treat effluents, to evaluate anaerobic activity in bioreactors or natural ecosystems, or to quantify inhibitory effects on methanogenic activity. These activity tests are usually based on the measurement of the volume of biogas produced by volumetric, pressure increase or gas chromatography (GC) methods. In this study, we present an alternative method for non-invasive measurement of methane produced during activity tests in closed vials, based on Infrared Tunable Diode Laser Absorption Spectroscopy (MA-TDLAS). This new method was tested during model acetoclastic and hydrogenotrophic methanogenic activity tests and was compared to a more traditional method based on gas chromatography. From the results obtained, the CH(4) detection limit of the method was estimated to 60 ppm and the minimum measurable methane production rate was estimated to 1.09(.)10(-3) mg l(-1) h(-1), which is below CH(4) production rate usually reported in both anaerobic reactors and natural ecosystems. Additionally to sensitivity, the method has several potential interests compared to more traditional methods among which short measurements time allowing the measurement of a large number of MA test vials, non-invasive measurements avoiding leakage or external interferences and similar cost to GC based methods. It is concluded that MA-TDLAS is a promising method that could be of interest not only in the field of anaerobic digestion but also, in the field of environmental ecology where CH(4) production rates are usually very low. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Review of Department of Energy HEPA filter test activities

    International Nuclear Information System (INIS)

    McIntyre, J.A.

    1993-01-01

    Filter Test Facilities (FTFs) and the FTF Technical Support Group (TSG) continue to provide services to the Department of Energy (DOE). Additional tasks relating to the HEPA filter cycle have been added to the TSG. The tasks include the quality assessment review for the in-place testing of HEPA filters at DOE sites and the formation of an in-place testing standards writing group. Summary of ongoing FTFs and TSG activities for FY 1990-FY 1992 including the technical input for implementation of the High Flow Alternative Test System (HFATS), update of the DOE Standards, the status of the quality assessment review and in-place testing standards writing group are discussed

  5. Design, analysis, and test of an active tubular interface

    Science.gov (United States)

    Elspass, Wilfried J.; Eerme, M.; Paradies, R.; Resch, Martin

    1997-06-01

    Space missions require higher and higher performance such as high pointing accuracy and stability, and high shape precision. Passive damping means often cannot fulfill the requirements. Besides space applications at the same time numerous applications in machine design require higher accuracy. For a lot of applications the passive measures come up against limits. Active technologies have to be considered more often. Active mechanical components are more and more used as a necessary step towards adaptive structures. Active mechanical interfaces are simpler systems having very useful applications and can be used as kind of test benches in order to master the most exacting technologies. The main advantages of such an active interface are the following: (1) state-of- the-art sensors and actuators can be used, (2) the mechanical design of the interface is conventional, (3) the passive behavior of the system is not deteriorated, (4) the design is compact and rather easy to integrate, (5) easy repair (replacement) of the active mechanical part, (6) standardization of the interfaces results in cost reductions. An important property in such intermediate step is that no major redesign of the conventionally designed mechanical structure should be needed. The design, numerical analysis, manufacturing and test of a fully integrated active tubular interface (ATI) is presented. The design of the ATI includes the optimal laminate stacking sequence with respect to maximum deformation efficiency. The results of an active damping application, an antenna support beam, including the controller layout are discussed.

  6. Application of charged particle activation for testing machine part wear

    International Nuclear Information System (INIS)

    Kosimova, M.; Tendera, P.

    1985-01-01

    The results of application of the charge particle activation method to investigate machine part wear are presented. Study of radionuclide activity and yield has been carried out at the U-120M isochronous cyclotron by means of the method of iron foil piles from 20 to 100 μm in thick. Protons and deuterons have been used. Wear measurement is based on determination of wear particle activity in a butyric medium. An example of the results of a bench test of activated piston rings and cylinder liner of the engine for trucks is given. The method of surface activation is shown to be acceptable for studying machine part wear under the regular service conditions, especially on the stage of the primary investigations and development, when sampling structural materials and estimating different lubricating oil applicability

  7. Active Test of Purification Facility at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Iseki, Tadahiro; Tsujimura, Akino; Nitta, Takeshi; Matsuda, Takashi

    2007-01-01

    During the second and third steps of Active Test of the Plutonium Purification unit, the extraction and reextraction performances of pulsed columns and mixer-settlers have been checked. Plutonium losses into wastes have been also checked. As a result, it was confirmed that the expected performances had been achieved. (authors)

  8. Active earth pressure model tests versus finite element analysis

    Science.gov (United States)

    Pietrzak, Magdalena

    2017-06-01

    The purpose of the paper is to compare failure mechanisms observed in small scale model tests on granular sample in active state, and simulated by finite element method (FEM) using Plaxis 2D software. Small scale model tests were performed on rectangular granular sample retained by a rigid wall. Deformation of the sample resulted from simple wall translation in the direction `from the soil" (active earth pressure state. Simple Coulomb-Mohr model for soil can be helpful in interpreting experimental findings in case of granular materials. It was found that the general alignment of strain localization pattern (failure mechanism) may belong to macro scale features and be dominated by a test boundary conditions rather than the nature of the granular sample.

  9. A review of DOE HEPA filter component test activities

    Energy Technology Data Exchange (ETDEWEB)

    Slawski, J.W.; Bresson, J.F. [Informatics Corp., Inc., Albuquerque, NM (United States); Scripsick, R.C. [Los Alamos National Lab., NM (United States)

    1997-08-01

    All HEPA filters purchased for installation in DOE nuclear facilities are required to be tested at a Filter Test Facility (FTF) prior to installation. The number of HEPA filters purchased by DOE has been reduced so much that the Hanford FTF was closed. From Fiscal Year (FY) 1992 to 1994, funding was not provided to the FTF Technical Support Group (TSG) at the Los Alamos National Laboratory. As a consequence, Round Robin Tests (RRTs), performed twice each year by the FTFs to assess constituency of test results among the FTFs, were not performed in FY 1992 and FY 1993. The Annual Reports of FTF test activities were not prepared for FY 1992 - 1995. Technical support provided to the FTFs was minimal. There is talk of closing a second FTF, and ongoing discussions as to whether DOE will continue to fund operation of the FTFs. In FY 1994, DOE Defense Programs commenced funding the TSG. RRT data for FY 1994 and 1995 have been entered into the database; the FY 1994 RRT report has been issued; and the FY 1995 RRT report is in progress. Data from semiannual reports have been retrieved and entered into the database. Standards related to HEPA filter test and procurement activities are now scheduled for issuance by FY 1996. Continuation of these activities depends on whether DOE will continue to support the HEPA filter test program. The history and activities of the FTFs and the TSG at Los Alamos have been reported at previous Air Cleaning Conferences. Data from the FY 1991 Annual Report of FTF activities was presented at the 1992 Air Cleaning Conference. Preparation of the Annual Reports was temporarily suspended in 1992. However, all of the FTF Semiannual report data have been retrieved and entered into the data base. This paper focuses primarily on the results of HEPA filter tests conducted by FTFs during FY 1992 - FY 1995, and the possible effects of the DOE program uncertainties on the quality of HEPA filters for installation at the DOE sites. 15 refs., 13 tabs.

  10. Importance of basophil activation testing in insect venom allergy

    Directory of Open Access Journals (Sweden)

    Kosnik Mitja

    2009-12-01

    Full Text Available Abstract Background Venom immunotherapy (VIT is the only effective treatment for prevention of serious allergic reactions to bee and wasp stings in sensitized individuals. However, there are still many questions and controversies regarding immunotherapy, like selection of the appropriate allergen, safety and long term efficacy. Methods Literature review was performed to address the role of basophil activation test (BAT in diagnosis of venom allergy. Results In patients with positive skin tests or specific IgE to both honeybee and wasp venom, IgE inhibition test can identify sensitizing allergen only in around 15% and basophil activation test increases the identification rate to around one third of double positive patients. BAT is also diagnostic in majority of patients with systemic reactions after insect stings and no detectable IgE. High basophil sensitivity to allergen is associated with a risk of side effects during VIT. Persistence of high basophil sensitivity also predicts a treatment failure of VIT. Conclusion BAT is a useful tool for better selection of allergen for immunotherapy, for identification of patients prone to side effects and patients who might be treatment failures. However, long term studies are needed to evaluate the accuracy of the test.

  11. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  12. Adaptive and robust active vibration control methodology and tests

    CERN Document Server

    Landau, Ioan Doré; Castellanos-Silva, Abraham; Constantinescu, Aurelian

    2017-01-01

    This book approaches the design of active vibration control systems from the perspective of today’s ideas of computer control. It formulates the various design problems encountered in the active management of vibration as control problems and searches for the most appropriate tools to solve them. The experimental validation of the solutions proposed on relevant tests benches is also addressed. To promote the widespread acceptance of these techniques, the presentation eliminates unnecessary theoretical developments (which can be found elsewhere) and focuses on algorithms and their use. The solutions proposed cannot be fully understood and creatively exploited without a clear understanding of the basic concepts and methods, so these are considered in depth. The focus is on enhancing motivations, algorithm presentation and experimental evaluation. MATLAB®routines, Simulink® diagrams and bench-test data are available for download and encourage easy assimilation of the experimental and exemplary material. Thre...

  13. Design and Calibration Tests of an Active Sound Intensity Probe

    Directory of Open Access Journals (Sweden)

    Thomas Kletschkowski

    2008-01-01

    Full Text Available The paper presents an active sound intensity probe that can be used for sound source localization in standing wave fields. The probe consists of a sound hard tube that is terminated by a loudspeaker and an integrated pair of microphones. The microphones are used to decompose the standing wave field inside the tube into its incident and reflected part. The latter is cancelled by an adaptive controller that calculates proper driving signals for the loudspeaker. If the open end of the actively controlled tube is placed close to a vibrating surface, the radiated sound intensity can be determined by measuring the cross spectral density between the two microphones. A one-dimensional free field can be realized effectively, as first experiments performed on a simplified test bed have shown. Further tests proved that a prototype of the novel sound intensity probe can be calibrated.

  14. Metabolic Activity Interferometer: A Powerful Tool for Testing Antibiotics

    Directory of Open Access Journals (Sweden)

    Rachel R. P. Machado

    2012-01-01

    Full Text Available It is demonstrated that the efficiency of antibiotics can be tested using an interferometric method. Two antibiotics were used as models to show that an interferometric method to monitor the metabolic activity of slowly growing bacteria can be a safer method to judge antimicrobial properties of substances than conventional methods. The susceptibility of Mycobacterium bovis to hexane extract of Pterodon emarginatus and to the well-known antibiotic rifampicin was tested with the interferometric method and with the conventional microplate method. The microplate method revealed a potential activity of hexane extract against M. bovis. However, the interferometric method showed that the action of this substance is rather limited. Also in the case of rifampicin, the interferometric method was able to detect resistant bacteria.

  15. Importance of basophil activation testing in insect venom allergy

    OpenAIRE

    Kosnik Mitja; Korosec Peter

    2009-01-01

    Abstract Background Venom immunotherapy (VIT) is the only effective treatment for prevention of serious allergic reactions to bee and wasp stings in sensitized individuals. However, there are still many questions and controversies regarding immunotherapy, like selection of the appropriate allergen, safety and long term efficacy. Methods Literature review was performed to address the role of basophil activation test (BAT) in diagnosis of venom allergy. Results In patients with positive skin te...

  16. Evaluation of basophil activation test in suspected food hypersensitivity.

    Science.gov (United States)

    Pignatti, Patrizia; Yacoub, Mona-Rita; Testoni, Claudia; Pala, Gianni; Corsetti, Maura; Colombo, Giselda; Meriggi, Antonio; Moscato, Gianna

    2017-07-01

    Food hypersensitivity is characterized by a wide range of symptoms. The relationship between symptoms and food is more frequently suspected than objectively proven. Basophil activation test (BAT) is based on the evaluation of activation markers on blood basophils in vitro stimulated with drugs or allergens. The aim of the study was to evaluate the usefulness of BAT when introduced in the routine work-up of suspected food hypersensitivity. BAT was requested in subjects with food adverse reactions when a discrepancy existed among history and skin prick test (SPT) and/or specific IgE. Data from 150 subjects were analysed using CD63 as basophil activation marker. Thirty controls were evaluated for cut-offs. Immunoblots was performed with the sera of representative subjects positive for BAT and negative for SPT and sIgE. 1,024 BAT were carried out, the agreement (positive/positive and negative/negative) was 78.5% for BAT vs. SPT and 78.3% for BAT vs. IgE. Atopic patients, but not atopic controls, more frequently had a positive BAT than non-atopic patients (P tested food) and both negative sIgE and SPT. Immunoblots revealed the presence of sIgE for the tested foods in representative patients with positive BAT, negative SPT and sIgE. Introduction of BAT in routine of food hypersensitivity, limited to subjects with a discrepancy between history and traditional tests, might be useful particularly when total IgE are low. © 2015 International Clinical Cytometry Society. © 2015 International Clinical Cytometry Society.

  17. Hepatitis A virus: a test method for virucidal activity.

    Science.gov (United States)

    Wolff, M H; Schmitt, J; Rahaus, M; König, A

    2001-08-01

    Hepatitis A virus (HAV) is closely related to the genus enterovirus. HAV is very stable and resistant to acid pH and elevated temperature, as well as to chemicals and environmental influences. Human poliovirus is still one of the model viruses for testing disinfectants but there are discussions about changing to hepatitis A virus. The purpose of this study was to develop a method for using adapted hepatitis A virus to test hand disinfectants. Using HAV strains HM175/24a and FRhK-4 cytopathic effects were visible rarely, and not before 14 days. To verify virus growth in cells a RT-PCR was developed. Two disinfectants tested did not show the required virucidal activity to satisfy current German guidelines.

  18. Preference as a Function of Active Interresponse Times: A Test of the Active Time Model

    Science.gov (United States)

    Misak, Paul; Cleaveland, J. Mark

    2011-01-01

    In this article, we describe a test of the active time model for concurrent variable interval (VI) choice. The active time model (ATM) suggests that the time since the most recent response is one of the variables controlling choice in concurrent VI VI schedules of reinforcement. In our experiment, pigeons were trained in a multiple concurrent…

  19. Versatile equipment for mechanical testing of active materials

    International Nuclear Information System (INIS)

    Bertsch, Johannes; Heimgartner, Peter

    2005-01-01

    At the Paul Scherrer Institute (PSI) 3 different project groups presently perform aging research on active materials. The research fields are fusion, high neutron flux targets and LWR relevant components. Up to now mechanical testing has been performed with small, low dose rate samples behind local shielding, not appropriate for highly activated material. To overcome this situation, a cell concept for active mechanical testing was elaborated and has been erected in PSI's Hotlab. It consists of 4 shielded cells. 3 connected cells are versatile and independently operable for highly beta/gamma active samples. One cell is an alpha/beta/gamma-box which will be realized in a second phase. This paper presents the versatility especially of the beta/gamma-cells: The different user groups perform experiments in these cells, whereas different machines can be placed into the cells. As consequence of the need of heavily shielded cell doors, a special strengthening and levelling of the floor has been required. In all cells the relevant media are installed. Besides the performance of the cells, the project progress as the difficulties and their solutions are described. (Author)

  20. First Test of Fan Active Noise Control (ANC) Completed

    Science.gov (United States)

    2005-01-01

    With the advent of ultrahigh-bypass engines, the space available for passive acoustic treatment is becoming more limited, whereas noise regulations are becoming more stringent. Active noise control (ANC) holds promise as a solution to this problem. It uses secondary (added) noise sources to reduce or eliminate the offending noise radiation. The first active noise control test on the low-speed fan test bed was a General Electric Company system designed to control either the exhaust or inlet fan tone. This system consists of a "ring source," an induct array of error microphones, and a control computer. Fan tone noise propagates in a duct in the form of spinning waves. These waves are detected by the microphone array, and the computer identifies their spinning structure. The computer then controls the "ring source" to generate waves that have the same spinning structure and amplitude, but 180 out of phase with the fan noise. This computer generated tone cancels the fan tone before it radiates from the duct and is heard in the far field. The "ring source" used in these tests is a cylindrical array of 16 flat-plate acoustic radiators that are driven by thin piezoceramic sheets bonded to their back surfaces. The resulting source can produce spinning waves up to mode 7 at levels high enough to cancel the fan tone. The control software is flexible enough to work on spinning mode orders from -6 to 6. In this test, the fan was configured to produce a tone of order 6. The complete modal (spinning and radial) structure of the tones was measured with two builtin sets of rotating microphone rakes. These rakes provide a measurement of the system performance independent from the control system error microphones. In addition, the far-field noise was measured with a semicircular array of 28 microphones. This test represents the first in a series of tests that demonstrate different active noise control concepts, each on a progressively more complicated modal structure. The tests are

  1. Comparative activity of carbapenem testing (the COMPACT study in Turkey

    Directory of Open Access Journals (Sweden)

    Leblebicioglu Hakan

    2012-02-01

    Full Text Available Abstract Background Recent evidence indicates that Gram-negative bacterial pathogens, the most common of which are Pseudomonas spp., Enterobacteriaceae, and Acinetobacter baumannii, are frequent causes of hospital-acquired infections. This study aims to evaluate the in vitro activity of doripenem and comparator carbapenem antibiotics against Gram-negative clinical isolates collected from COMParative Activity of Carbapenem Testing (COMPACT study centres in Turkey. Methods Ten centres in Turkey were invited to submit Pseudomonas aeruginosa, Enterobacteriaceae, and other Gram-negative isolates from intensive care unit (ICU/non-ICU patients with complicated intra-abdominal infections, bloodstream infections, or nosocomial pneumonia, including ventilator-associated pneumonia, between May and October 2008. Susceptibility was determined by each centre using E-test. A central laboratory performed species confirmation as well as limited susceptibility and quality-control testing. Results Five hundred and ninety six isolates were collected. MIC90 values for doripenem, meropenem, and imipenem, respectively, were 32, ≥ 64, and ≥ 64 mg/L against Pseudomonas spp.; 0.12, 0.12, and 0.5 mg/L against Enterobacteriaceae; and ≥ 64 mg/L for each against other Gram-negative isolates. In determining the susceptibility of hospital isolates of selected Gram-negative pathogens to doripenem, imipenem, and meropenem, we found that against all pathogens combined, the MIC90 for ICU compared with non-ICU isolates was higher. Conclusions Doripenem showed similar or slightly better activity than meropenem and better activity than imipenem against the Gram-negative pathogens collected in Turkey.

  2. Active Blade Vibration Control Being Developed and Tested

    Science.gov (United States)

    Johnson, Dexter

    2003-01-01

    Gas turbine engines are currently being designed to have increased performance, lower weight and manufacturing costs, and higher reliability. Consequently, turbomachinery components, such as turbine and compressor blades, have designs that are susceptible to new vibration problems and eventual in-service failure due to high-cycle fatigue. To address this problem, researchers at the NASA Glenn Research Center are developing and testing innovative active blade vibration control concepts. Preliminary results of using an active blade vibration control system, involving a rotor supported by an active magnetic bearing in Glenn's Dynamic Spin Rig, indicate promising results (see the photograph). Active blade vibration control was achieved using feedback of blade strain gauge signals within the magnetic bearing control loop. The vibration amplitude was reduced substantially (see the graphs). Also, vibration amplitude amplification was demonstrated; this could be used to enhance structural mode identification, if desired. These results were for a nonrotating two-bladed disk. Tests for rotating blades are planned. Current and future active blade vibration control research is planned to use a fully magnetically suspended rotor and smart materials. For the fully magnetically suspended rotor work, three magnetic bearings (two radial and one axial) will be used as actuators instead of one magnetic bearing. This will allow additional degrees of freedom to be used for control. For the smart materials work, control effectors located on and off the blade will be considered. Piezoelectric materials will be considered for on-the-blade actuation, and actuator placement on a stator vane, or other nearby structure, will be investigated for off-the-blade actuation. Initial work will focus on determining the feasibility of these methods by performing basic analysis and simple experiments involving feedback control.

  3. Activation and afterheat analyses for the HCPB test blanket

    International Nuclear Information System (INIS)

    Pereslavtsev, P.; Fischer, U.

    2007-01-01

    The Helium-Cooled Pebble Bed (HCPB) blanket is one of two breeder blanket concepts developed in the framework of the European Fusion Technology Programme for performance tests in ITER. The recent development programme focussed on the detailed engineering design of the Test Blanket Module (TBM) and associated systems including the assessment of safety and licensing related issues with the objective to prepare for a preliminary Safety Report. To provide a sound data basis for the safety analyses of the HCPB TBM system in ITER, the afterheat and activity inventories were assessed making use of a code system that allows performing 3D activation calculations by linking the Monte Carlo transport code MCNP and the fusion inventory code FISPACT through an appropriate interface. A suitable MCNP model of a 20 degree ITER torus sector with an integrated TBM of the HCPB PI (Plant Integration) type in the horizontal test blanket port was developed and adapted to the requirements for coupled 3D neutron transport and activation calculations. Two different irradiation scenarios were considered in the coupled 3D neutron transport and activation calculations. The first one is representative for the TBM irradiation in ITER with a total of 9000 neutron pulses over a three (calendar) years period. It was simulated by a continuous irradiation for 3 years minus the last month and a discontinuous irradiation with 250 pulses (420 s pulse length, 1200 s power-off in between) over the last month. The second (conservative) irradiation scenario assumes an extended irradiation time over the full anticipated lifetime of ITER according to the M-DRG-1 irradiation scenario with a total first wall fluence of 0.3 MWa/m 2 . For both irradiation scenarios the radioactivity inventories, the afterheat and the contact gamma dose were calculated as function of the decay time. Data were processed for the total activity and afterheat of the TBM, its constituting components and materials including their

  4. Active test of purification facility at Rokkasho reprocessing plant

    Energy Technology Data Exchange (ETDEWEB)

    Ishio, Takahiro; Sato, Nobuharu; Inaba, Makoto; Itagaki, Takashi [Purification Section, Plant Operation Department, Reprocessing Plant, Reprocessing Business Division, Japan Nuclear Fuel Limited, 4-108, Aza Okitsuke, Oaza Obuchi, Rokkasho-mura, Kamikita-gun, Aomori-ken (Japan)

    2009-06-15

    I. Introduction: At RRP, following the completion of Water Test, Chemical Test (CT) and Uranium Test (UT), the Active Test (AT) with actual spent fuel assemblies has been performed since March of 2006. This paper deals with the AT of the plutonium purification unit at RRP. II. Outline of plutonium purification unit: The plutonium purification unit purifies plutonium nitrate sent from the Separation Facility, and it has 5 pulsed columns and 4 mixer-settlers. Plutonium valence is adjusted to Pu{sup 4+} in plutonium nitrate sent from the Separation Facility, and then plutonium is extracted into organic phase (tri-butyl phosphate: TBP) in the extraction column. At this time, most of fission products remain in aqueous phase (nitric acid solution), which is discharged as raffinate through the diluent washing column. The fission products still contained in loaded organic solvent are removed in the FP scrubbing column, and then plutonium is stripped with nitric acid solution including hydroxylamine nitrate (HAN) as reducer. After TBP contained in purified plutonium nitrate solution is removed in the diluent washing bank with n-dodecane, it is sent to the plutonium concentration unit. Organic solvent used in the stripping column is sent to the plutonium barrier bank in order to remove remaining plutonium with uranous nitrate and hydrazine nitrate solution, and organic solvent is sent to the solvent regeneration unit. III. Active test results: The main purpose of the AT on the plutonium purification unit is (1) checking the performance of plutonium extraction and stripping, (2) checking the efficiency of diluent washing. III.A. Plutonium Extraction and Stripping performances: As a result of the neutron monitor profile on the extraction column during the representative operation, extraction was completed at the upper part of the column. As for the neutron monitor profile on the stripping column, stripping was performed at the lower part of the column. Plutonium concentration

  5. Market risk stress testing for internationally active financial institutions

    Directory of Open Access Journals (Sweden)

    Marković Petar

    2011-01-01

    Full Text Available The paper develops a comprehensive framework for market risk stress testing in internationally active financial institutions. We begin by defining the scope and type of the stress test and explaining how to select risk factors and the stress time horizon. We then address challenges related to data gathering, followed by in-depth discussion of techniques for developing realistic shock scenarios. Next the process of shock application to a particular portfolio is described, followed by determination of portfolio profit and loss. We conclude by briefly discussing the issue of assigning probability to stress scenarios. We illustrate the framework by considering the development of a ‘worst case’ scenario using global financial market data from Thomson Reuters Datastream.

  6. Junction temperature estimation for an advanced active power cycling test

    DEFF Research Database (Denmark)

    Choi, Uimin; Blaabjerg, Frede; Jørgensen, S.

    2015-01-01

    estimation method using on-state VCE for an advanced active power cycling test is proposed. The concept of the advanced power cycling test is explained first. Afterwards the junction temperature estimation method using on-state VCE and current is presented. Further, the method to improve the accuracy...... of the maximum junction temperature estimation is also proposed. Finally, the validity and effectiveness of the proposed method is confirmed by experimental results.......On-state collector-emitter voltage (VCE) is a good indicator to determine the wear-out condition of power device modules. Further, it is a one of the Temperature Sensitive Electrical Parameters (TSEPs) and thus can be used for junction temperature estimation. In this paper, the junction temperature...

  7. Utilisation of Wearable Computing for Space Programmes Test Activities Optimasation

    Science.gov (United States)

    Basso, V.; Lazzari, D.; Alemanni, M.

    2004-08-01

    New technologies are assuming a relevant importance in the Space business domain also in the Assembly Integration and Test (AIT) activities allowing process optimization and capability that were unthinkable only few years ago. This paper has the aim to describe Alenia Spazio (ALS) gained experience on the remote interaction techniques as a results of collaborations established both on European Communities (EC) initiatives, with Alenia Aeronautica (ALA) and Politecnico of Torino (POLITO). The H/W and S/W components performances increase and costs reduction due to the home computing massive utilization (especially demanded by the games business) together with the network technology possibility (offered by the web as well as the hi-speed links and the wireless communications) allow today to re-think the traditional AIT process activities in the light of the multimedia data exchange: graphical, voice video and by sure more in the future. Aerospace business confirm its innovation vocation which in the year '80 represents the cradle of the CAD systems and today is oriented to the 3D data visualization/ interaction technologies and remote visualisation/ interaction in collaborative way on a much more user friendly bases (i.e. not for specialists). Fig. 1 collects AIT extended scenario studied and adopted by ALS in these years. ALS experimented two possibilities of remote visualization/interaction: Portable [e.g. Fig.2 Personal Digital Assistant (PDA), Wearable] and walls (e.g.VR-Lab) screens as both 2D/3D visualisation and interaction devices which could support many types of traditional (mainly based on EGSE and PDM/CAD utilisation/reports) company internal AIT applications: 1. design review support 2. facility management 3. storage management 4. personnel training 5. integration sequences definition 6. assembly and test operations follow up 7. documentation review and external access to AIT activities for remote operations (e.g. tele-testing) EGSE Portable Clean room

  8. Activity calibration in breath test for diagnosis of Helicobacter pylori

    International Nuclear Information System (INIS)

    Wasilewka-Radwanska, M.; Pysklak, S.; Gilewicz-Wolter, J.; Kuc, T.; Jung, A.; Niziol, J.; Kopanski, J.; Micherdzinski, J.; Cienciala, A.

    1996-01-01

    Some technical and measurement problems of the breath test for diagnosis of Helicobacter pylori are briefly discussed. Calibrated results obtained for population of 108 cases indicate difference between HP+ (infected with Helicobacter pylori) and HP- (non infected with Helicobacter pylori) in exhaled 14 C activity not less than 3.9 kBq while the lower limit for HP+ cases was set at 6.8 kBq at the detection limit: 0.9 Bq/mmol of CO 2 . It was estimated that in exhalation way up to 29% of the taken activity was removed in HP+ cases during first 35 minutes. Radiation hazard for the patient system is negligibly small - dose equipment not exceeds 0.29% of the natural (environmental) yearly exposure. (author)

  9. Strength and leak testing of plasma activated bonded interfaces

    DEFF Research Database (Denmark)

    Visser, M.M.; Weichel, Steen; Reus, Roger De

    2002-01-01

    on detection of changes in membrane deflections. The detection limit for leak was 8E-13 mbar l/s. For comparison, strength and leak tests were also performed with regular fusion bonded wafers annealed at 1100 degreesC. The PAB was found to withstand post-processing steps such as RCA cleaning, 24 h in de......-ionised water (DIW), 24 h in 2.5% HF, 24 h in acetone and 60 s in a resist developer. By analysing the thin silicon oxide present on the surfaces to be bonded with optical methods, the influence of pre-cleaning and activation process parameters was investigated....

  10. Inflammatory aetiology of human myometrial activation tested using directed graphs.

    Directory of Open Access Journals (Sweden)

    2005-07-01

    Full Text Available THERE ARE THREE MAIN HYPOTHESES FOR THE ACTIVATION OF THE HUMAN UTERUS AT LABOUR: functional progesterone withdrawal, inflammatory stimulation, and oxytocin receptor activation. To test these alternatives we have taken information and data from the literature to develop causal pathway models for the activation of human myometrium. The data provided quantitative RT-PCR results on key genes from samples taken before and during labour. Principal component analysis showed that pre-labour samples form a homogenous group compared to those during labour. We therefore modelled the alternative causal pathways in non-labouring samples using directed graphs and statistically compared the likelihood of the different models using structural equations and D-separation approaches. Using the computer program LISREL, inflammatory activation as a primary event was highly consistent with the data (p = 0.925, progesterone withdrawal, as a primary event, is plausible (p = 0.499, yet comparatively unlikely, oxytocin receptor mediated initiation is less compatible with the data (p = 0.091. DGraph, a software program that creates directed graphs, produced similar results (p= 0.684, p= 0.280, and p = 0.04, respectively. This outcome supports an inflammatory aetiology for human labour. Our results demonstrate the value of directed graphs in determining the likelihood of causal relationships in biology in situations where experiments are not possible.

  11. [Clinical investigation of basophil activation test as a complementary test for house dust mite allergen].

    Science.gov (United States)

    Ren, H L; Li, J D; Miao, Y H; Xu, T

    2018-03-01

    Objective: To investigate the clinical application of glass micro fiber basophil activation test (BAT) used as a complementary test for house dust mite allergen. Method: Forty patients with clinical diagnosed allergic rhinitis was test by three methods for house dust mite allergen, skin prick test(SPT),Immuno CAP sIgE, and BAT in vitro. The sensitivity and specificity of glass micro fiber were accessed, and the consistency between BAT, SPT, and Immuno sIgE was analyzed. As in vivo provocation was not performed, gold standard is regarded as the combination of medical history and positive reports of SPT and/or ImmunoCAP sIgE test. Result: Twentythree patients are diagnosed as house dust mite allergic rhinitis by gold standard. The sensitivity and specificity of glass micro fiber BAT were 60.9% and 88.2%, the sensitivity of SPT and sIgE was 87.0% and sIgE 73.9%. The correlation rates between BAT with SPT is 0.67( P house dust mite allergic rhinitis, BAT have a good consistency with SPT and sIgE, while as it has only moderate consistency with "gold standard", further studies are needed to prove its clinical significance. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  12. Field-Testing of an Active Laser Tracking System

    Science.gov (United States)

    Markov, V.; Khiznyak, A.; Woll, D.; Liu, S.

    Comprehensive space surveillance demands a more accurate technique in tracking multi-dimensional state vector (3D coordinate, velocity, vibration, etc.) of the space objects. RF radiometric techniques typically can not provide the needed accuracy, while passive optical (and laser) tracking systems can provide distance to the object and its angular position, but not a direct reading of velocity, the parameter of primary importance for space object tracking and characterization. Addressing this problem with active optical tracking techniques is challenging because of the great distances involved, the high velocity of the satellites, and the optical aberrations induced by the atmosphere. We have proposed a phase conjugation based laser tracking concept, and accomplished the first version of design and engineering of a prototype for an Active Laser Tracking System (ALTS). In its current state the ALTS is capable to demonstrate the very basics operational principles of the proposed active tracking technique. We then performed a number of experiments to prove operational capabilities of this prototype both at MetroLaser's lab environment and at Edwards AFB Test Range. In its current architecture the ALTS is comprised of two laser cavities, Master and Slave that are coupled through a Phase Conjugate Mirror (PCM) formed in a non-linear medium (NLM) set at Master laser cavity. By pumping NLM and forming PCM, Master laser establishes the cavities coupling mode and injects the photons in the slave cavity. It is essential that the specific features of the PCM not only serve to couple ALTS cavities, but also serves to compensate optical aberrations of the ALTS (gain media and optical elements of the laser resonator). Due to its ability to compensate optical aberrations, phase conjugate resonators are capable of sustaining oscillation with a remote target as an output coupler. The entire system comprises of several modules, including a laser, emitting/receiving telescope, gimbal

  13. Tc-99 Adsorption on Selected Activated Carbons - Batch Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Wellman, Dawn M.; Golovich, Elizabeth C.; Cordova, Elsa A.; Smith, Ronald M.

    2010-12-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently developing a 200-West Area groundwater pump-and-treat system as the remedial action selected under the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision for Operable Unit (OU) 200-ZP-1. This report documents the results of treatability tests Pacific Northwest National Laboratory researchers conducted to quantify the ability of selected activated carbon products (or carbons) to adsorb technetium-99 (Tc-99) from 200-West Area groundwater. The Tc-99 adsorption performance of seven activated carbons (J177601 Calgon Fitrasorb 400, J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, J177612 Norit GAC830, J177613 Norit GAC830, and J177617 Nucon LW1230) were evaluated using water from well 299-W19-36. Four of the best performing carbons (J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, and J177613 Norit GAC830) were selected for batch isotherm testing. The batch isotherm tests on four of the selected carbons indicated that under lower nitrate concentration conditions (382 mg/L), Kd values ranged from 6,000 to 20,000 mL/g. In comparison. Under higher nitrate (750 mg/L) conditions, there was a measureable decrease in Tc-99 adsorption with Kd values ranging from 3,000 to 7,000 mL/g. The adsorption data fit both the Langmuir and the Freundlich equations. Supplemental tests were conducted using the two carbons that demonstrated the highest adsorption capacity to resolve the issue of the best fit isotherm. These tests indicated that Langmuir isotherms provided the best fit for Tc-99 adsorption under low nitrate concentration conditions. At the design basis concentration of Tc 0.865 µg/L(14,700 pCi/L), the predicted Kd values from using Langmuir isotherm constants were 5,980 mL/g and 6,870 mL/g for for the two carbons. These Kd values did not meet the target Kd value of 9,000 mL/g. Tests

  14. Vision-based Ground Test for Active Debris Removal

    Directory of Open Access Journals (Sweden)

    Seong-Min Lim

    2013-12-01

    Full Text Available Due to the continuous space development by mankind, the number of space objects including space debris in orbits around the Earth has increased, and accordingly, difficulties of space development and activities are expected in the near future. In this study, among the stages for space debris removal, the implementation of a vision-based approach technique for approaching space debris from a far-range rendezvous state to a proximity state, and the ground test performance results were described. For the vision-based object tracking, the CAM-shift algorithm with high speed and strong performance, and the Kalman filter were combined and utilized. For measuring the distance to a tracking object, a stereo camera was used. For the construction of a low-cost space environment simulation test bed, a sun simulator was used, and in the case of the platform for approaching, a two-dimensional mobile robot was used. The tracking status was examined while changing the position of the sun simulator, and the results indicated that the CAM-shift showed a tracking rate of about 87% and the relative distance could be measured down to 0.9 m. In addition, considerations for future space environment simulation tests were proposed.

  15. Positive affect and physical activity: Testing effects on goal setting, activation, prioritisation, and attainment.

    Science.gov (United States)

    Cameron, David S; Bertenshaw, Emma J; Sheeran, Paschal

    2018-02-01

    The present research tested whether incidental positive affect promotes pursuit of physical activity goals. Four key features of goal pursuit were examined - setting physical activity goals (Study 1), goal activation (Study 2), and goal prioritization and goal attainment (Study 3). Participants (N s = 80, 81, and 59, in Studies 1-3, respectively) were randomized to positive affect (joy, hope) or neutral affect (control) conditions in each study. Questionnaire measures of goal level, goal commitment, and means selection (Study 1); a lexical decision task indexed goal activation (Study 2), a choice task captured goal prioritization and MET minutes quantified goal attainment (Study 3). Study 1 showed that positive affect led to a greater number of intended physical activities, and that joy engendered greater willingness to try activities. In Study 2, a positive affect induction led to heightened activation of the physical activity goal compared to the control condition. The joy induction in Study 3 led to greater physical activity, and a trend towards greater goal prioritization. These findings suggest that positive affect enhances the pursuit of physical activity goals. Implications for health behavior theories and interventions are outlined.

  16. Laser active thermography for non-destructive testing

    International Nuclear Information System (INIS)

    Semerok, A.; Grisolia, C.; Fomichev, S.V.; Thro, P.Y.

    2013-01-01

    Thermography methods have found their applications in different fields of human activity. The non-destructive feature of these methods along with the additional advantage by automated remote control and tests of nuclear installations without personnel attendance in the contaminated zone are of particular interest. Laser active pyrometry and laser lock-in thermography for in situ non-destructive characterization of micrometric layers on graphite substrates from European tokamaks were under extensive experimental and theoretical studies in CEA (France). The studies were aimed to obtain layer characterization with cross-checking the layer thermal contact coefficients determined by active laser pyrometry and lock-in thermography. The experimental installation comprised a Nd-YAG pulsed repetition rate laser (1 Hz - 10 kHz repetition rate frequency, homogeneous spot) and a home-made pyrometer system based on two pyrometers for the temperature measurements in 500 - 2600 K range. For both methods, the layer characterization was provided by the best fit of the experimental results and simulations. The layer thermal contact coefficients determined by both methods were quite comparable. Though there was no gain in the measurements accuracy, lock-in measurements have proved their advantage as being much more rapid. The obtained experimental and theoretical results are presented. Some practical applications and possible improvements of the methods are discussed. (authors)

  17. Laser active thermography for non-destructive testing

    Science.gov (United States)

    Semerok, A.; Grisolia, C.; Fomichev, S. V.; Thro, P.-Y.

    2013-11-01

    Thermography methods have found their applications in different fields of human activity. The non-destructive feature of these methods along with the additional advantage by automated remote control and tests of nuclear installations without personnel attendance in the contaminated zone are of particular interest. Laser active pyrometry and laser lock-in thermography for in situ non-destructive characterization of micrometric layers on graphite substrates from European tokamaks were under extensive experimental and theoretical studies in CEA (France). The studies were aimed to obtain layer characterization with cross-checking the layer thermal contact coefficients determined by active laser pyrometry and lock-in thermography. The experimental installation comprised a Nd-YAG pulsed repetition rate laser (1 Hz - 10 kHz repetition rate frequency, homogeneous spot) and a home-made pyrometer system based on two pyrometers for the temperature measurements in 500 - 2600 K range. For both methods, the layer characterization was provided by the best fit of the experimental results and simulations. The layer thermal contact coefficients determined by both methods were quite comparable. Though there was no gain in the measurements accuracy, lock-in measurements have proved their advantage as being much more rapid. The obtained experimental and theoretical results are presented. Some practical applications and possible improvements of the methods are discussed.

  18. Discovery Channel Telescope active optics system early integration and test

    Science.gov (United States)

    Venetiou, Alexander J.; Bida, Thomas A.

    2012-09-01

    The Discovery Channel Telescope (DCT) is a 4.3-meter telescope with a thin meniscus primary mirror (M1) and a honeycomb secondary mirror (M2). The optical design is an f/6.1 Ritchey-Chrétien (RC) with an unvignetted 0.5° Field of View (FoV) at the Cassegrain focus. We describe the design, implementation and performance of the DCT active optics system (AOS). The DCT AOS maintains collimation and controls the figure of the mirror to provide seeing-limited images across the focal plane. To minimize observing overhead, rapid settling times are achieved using a combination of feed-forward and low-bandwidth feedback control using a wavefront sensing system. In 2011, we mounted a Shack-Hartmann wavefront sensor at the prime focus of M1, the Prime Focus Test Assembly (PFTA), to test the AOS with the wavefront sensor, and the feedback loop. The incoming wavefront is decomposed using Zernike polynomials, and the mirror figure is corrected with a set of bending modes. Components of the system that we tested and tuned included the Zernike to Bending Mode transformations. We also started open-loop feed-forward coefficients determination. In early 2012, the PFTA was replaced by M2, and the wavefront sensor moved to its normal location on the Cassegrain instrument assembly. We present early open loop wavefront test results with the full optical system and instrument cube, along with refinements to the overall control loop operating at RC Cassegrain focus.

  19. Basophil activation test: food challenge in a test tube or specialist research tool?

    Science.gov (United States)

    Santos, Alexandra F; Lack, Gideon

    2016-01-01

    Oral food challenge (OFC) is the gold-standard to diagnose food allergy; however, it is a labour and resource-intensive procedure with the risk of causing an acute allergic reaction, which is potentially severe. Therefore, OFC are reserved for cases where the clinical history and the results of skin prick test and/or specific IgE do not confirm or exclude the diagnosis of food allergy. This is a significant proportion of patients seen in Allergy clinics and results in a high demand for OFC. The basophil activation test (BAT) has emerged as a new diagnostic test for food allergy. With high diagnostic accuracy, it can be particularly helpful in the cases where skin prick test and specific IgE are equivocal and may allow reducing the need for OFC. BAT has high specificity, which confers a high degree of certainty in confirming the diagnosis of food allergy and allows deferring the performance of OFC in patients with a positive BAT. The diagnostic utility of BAT is allergen-specific and needs to be validated for different allergens and in specific patient populations. Standardisation of the laboratory methodology and of the data analyses would help to enable a wider clinical application of BAT.

  20. Basophil activation test with food additives in chronic urticaria patients.

    Science.gov (United States)

    Kang, Min-Gyu; Song, Woo-Jung; Park, Han-Ki; Lim, Kyung-Hwan; Kim, Su-Jung; Lee, Suh-Young; Kim, Sae-Hoon; Cho, Sang-Heon; Min, Kyung-Up; Chang, Yoon-Seok

    2014-01-01

    The role of food additives in chronic urticaria (CU) is still under investigation. In this study, we aimed to explore the association between food additives and CU by using the basophil activation test (BAT). The BAT using 15 common food additives was performed for 15 patients with CU who had a history of recurrent urticarial aggravation following intake of various foods without a definite food-specific IgE. Of the 15 patients studied, two (13.3%) showed positive BAT results for one of the tested food additives. One patient responded to monosodium glutamate, showing 18.7% of CD203c-positive basophils. Another patient showed a positive BAT result to sodium benzoate. Both patients had clinical correlations with the agents, which were partly determined by elimination diets. The present study suggested that at least a small proportion of patients with CU had symptoms associated with food additives. The results may suggest the potential utility of the BAT to identity the role of food additives in CU.

  1. Ceftaroline activity tested against contemporary Latin American bacterial pathogens (2011

    Directory of Open Access Journals (Sweden)

    Robert K. Flamm

    2014-03-01

    Full Text Available A total of 2484 target bacterial pathogens were collected (one per patient episode from patients in 16 Latin American medical centers located in seven nations during 2011. Isolate identity was confirmed at a coordinating laboratory and susceptibility testing was performed for ceftaroline and comparator agents according to reference broth microdilution methods. A total of 30.0% of isolates were from respiratory tract, 29.4% from skin and skin structure, 21.4% from blood stream, 7.9% from urinary tract and 11.3% from other sites. Ceftaroline was active against Staphylococcus aureus (42.8% MRSA with 83.6% of the isolates at ≤1 mg/L and all isolates at ≤2 mg/L (MIC5090, 0.25/2 mg/L. National MRSA rates ranged from a low of 28.8% in Colombia to a high of 68.1% in Chile. All Streptococcus pyogenes and Streptococcus agalactiae were susceptible to ceftaroline (MIC50/90 values were at ≤0.015/≤0.015 mg/L for both. All Streptococcus pneumoniae were susceptible to ceftaroline, linezolid, tigecycline and vancomycin. Susceptibility to ceftriaxone was at 88.4% (CLSI non-meningitis interpretive criteria and 73.9% (CLSI meningitis interpretive criteria for all S. pneumoniae. Ceftriaxone susceptibility was only at 33.3% (CLSI non-meningitis interpretive criteria and 0.0% (CLSI meningitis interpretive criteria for penicillin-intermediate (penicillin MIC, 4 mg/L strains. All Haemophilus influenzae (29.4% β-lactamase-positive isolates were susceptible to ceftaroline, amoxicillin–clavulanate, ceftriaxone, and levofloxacin. For the Latin American region, the ESBL-phenotype rate was 37.6% for Escherichia coli and 53.3% for Klebsiella pneumoniae. Ceftaroline was not active against ESBL-phenotype strains but was active against >90.0% of the non-ESBL-phenotype. The spectrum of activity of ceftaroline against pathogens from Latin America indicates that it merits further study for its potential use in the Latin American region.

  2. HAL/S-360 compiler test activity report

    Science.gov (United States)

    Helmers, C. T.

    1974-01-01

    The levels of testing employed in verifying the HAL/S-360 compiler were as follows: (1) typical applications program case testing; (2) functional testing of the compiler system and its generated code; and (3) machine oriented testing of compiler implementation on operational computers. Details of the initial test plan and subsequent adaptation are reported, along with complete test results for each phase which examined the production of object codes for every possible source statement.

  3. Testing of the activity of a zeolite hydrocracking catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Krichko, A A; Yulin, M K

    1973-01-01

    The activity of a catalyst having 3.5% of molybdena supported on the hydrogen form of sodium-Y zeolite remained constant during an 800 hour laboratory test carried out at 380/sup 0/C and 40 atm with an hourly space velocity of 1.0 and a hydrogen feed rate of 1000 l/l of feed on a 180 to 320/sup 0/C fraction obtained by hydrogenating a 35 : 65 mixture of coal and an atmospheric residuum boiling above 240/sup 0/C. The catalyst was first subjected to oxidative regeneration after 500 hours of high-temperature hydrogenation of aromatized extracts. A 56.2 to 61.9% conversion to a fraction boiling up to 180/sup 0/C was achieved with a 7.3 to 9.5% yield of gas consisting most of C/sub 3/-C/sub 4/ alkanes. The isobutene/n-butene ratio was 2.5 : 1 to 3.0 : 1. A 184 to 316/sup 0/C diesel fraction having a cetane number of 50.0 and a 46 to 177/sup 0/C gasoline fraction having a Motor octane number of 81.5 and a Research octane number of 91.0 were separated from the product.

  4. Neutron activation analysis method - international ring test for proficiency assessment

    International Nuclear Information System (INIS)

    Barbos, D.; Bucsa, A. F.

    2016-01-01

    The main objective of this test is to assess the quality control of analytical procedures for soils and plants which is of utmost importance to produce reliable and reproducible analytical data. For this purpose first, second, and third line quality control measures are taken in analytical laboratories. For first line control certified reference materials (CRM's) are preferred. However, the number and matrix variation in CRM's for environmental analytical research is still very limited. For second line control internal reference samples are often used, but again here the values for many element and parameter concentrations are questionable since almost no check versus CRM's is possible. For third line control participation in laboratory-evaluating exchange programs is recommended. This article contains the results achieved by our neutron activation analysis laboratory after irradiation experiment of soil and vegetation samples in TRIGA Reactor. All the samples were irradiated in the same location of the reactor in roughly similar conditions. (authors)

  5. LOW ACTIVITY WASTE FEED SOLIDS CARACTERIZATION AND FILTERABILITY TESTS

    Energy Technology Data Exchange (ETDEWEB)

    McCabe, D.; Crawford, C.; Duignan, M.; Williams, M.; Burket, P.

    2014-04-03

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant (WTP) that is currently under construction. The baseline plan for the WTP Pretreatment facility is to treat the waste, splitting it into High Level Waste (HLW) feed and Low Activity Waste (LAW) feed. Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed onsite in the Integrated Disposal Facility (IDF). There are currently no plans to treat the waste to remove technetium in the WTP Pretreatment facility, so its disposition path is the LAW glass. Options are being explored to immobilize the LAW portion of the tank waste, i.e., the LAW feed from the WTP Pretreatment facility. Removal of {sup 99}Tc from the LAW Feed, followed by off-site disposal of the {sup 99}Tc, would eliminate a key risk contributor for the IDF Performance Assessment (PA) for supplemental waste forms, and has potential to reduce treatment and disposal costs. Washington River Protection Solutions (WRPS) is developing some conceptual flow sheets for LAW treatment and disposal that could benefit from technetium removal. One of these flowsheets will specifically examine removing {sup 99}Tc from the LAW feed stream to supplemental immobilization. The conceptual flow sheet of the {sup 99}Tc removal process includes a filter to remove insoluble solids prior to processing the stream in an ion exchange column, but the characteristics and behavior of the liquid and solid phases has not previously been investigated. This report contains results of testing of a simulant that represents the projected composition of the feed to the Supplemental LAW process. This feed composition is not identical to the aqueous tank waste fed to the Waste Treatment Plant because it has been processed through WTP Pretreatment facility and therefore contains internal changes and recycle streams that will be generated within the WTP process. Although

  6. Vancomycin-resistant enterococci: validation of susceptibility testing and in vitro activity of novel antibiotics

    DEFF Research Database (Denmark)

    Rathe, Mathias; Lise, Kristensen,; Ellermann-Eriksen, Svend

    Vancomycin-resistant enterococci: validation of susceptibility testing and in vitro activity of novel antibiotics......Vancomycin-resistant enterococci: validation of susceptibility testing and in vitro activity of novel antibiotics...

  7. Comparison of coagulation activity tests in vitro for selected biomaterials

    NARCIS (Netherlands)

    van Oeveren, W; Haan, J; Lagerman, P; Schoen, T

    Testing of coagulation induced by external communicating medical devices is an International Standardisation Organization (ISO) requirement for products exposed to human blood. Four categories of tests are indicated by ISO 10993/4: a clotting test (partial thromboplastin time; PTT), thrombin

  8. Test installation for separation of contaminated/activated concrete

    International Nuclear Information System (INIS)

    Klok, H.; Peeze Binkhorst, I.A.G.M.

    1993-01-01

    Large amounts of contaminated concrete are released when dismantling nuclear power plants. Volume reduction of contaminated concrete has economic and environmental advantages. A test facility has been built by which contaminated concrete can be separated in clean aggregate and contaminated cement. During the tests a considerable amount of dust accumulated in the valve construction of the test installation. This could result in an unacceptable accumulation of contaminated dust, blocking of the handle and emission of dust and grit during the operation of the test facility. The design of the valve construction was adjusted by using and testing flexible materials

  9. HIPPARCOS satellite: Aeritalia involvement and system test activities and results

    Science.gov (United States)

    Strim, B.; Cugno, W.; Morsillo, G.

    In 1989 the European Space Agency is scheduled to launch HIPPARCOS on a 2.5-year mission that will revolutionize the state of astronomy. This is the first satellite to be dedicated to astrometry, a branch of astronomy that deals with the position of celestial objects and their motion in space. With an accuracy impossible to achieve from Earth, HIPPARCOS will make position, trigonometric parallax and proper motion measurements of some 100.000 pre-selected stars. The data will be used to calculate each star's distance and motion, providing astronomers with an unprecedented map of the heavens. In the end, the HIPPARCOS mission is expected to reveal surprisingly new insight into theories of stellar evolution, as well as into the nature of our galaxy and the universe. The program has been awarded to the MESH industrial consortium for definition, development and production. The French firm MATRA (prime contractor) and the AERITALIA SPACE SYSTEMS GROUP (major co-contractor) share program responsibility. AERITALIA is in charge of the spacecraft or "service module". This is the structural platform for the telescope payload and provides all subsystem services including thermal control, data handling, telecommunications, electrical power distribution, power generation, attitude and orbit control, and apogee kick motor. AERITALIA is responsible for the procurement of all spacecraft subsystems for which it directs the activities of a multinational team of subcontractors. In addition, it is in charge of the satellite's final assembly, integration and testing, as well as for the procurement of all ground support equipment for satellite testing. HIPPARCOS stands for HIgh Precision PARallax COllecting Satellite. Its name is also intended to honor the Greek astronomer Hipparchus (190-120 BC) who compiled the first star catalog and who first used trigonometric parallax to calculate the distance to the moon. (Parallax is the apparent shift in a celestial body's position in the sky

  10. Monkey Feeding Assay for Testing Emetic Activity of Staphylococcal Enterotoxin.

    Science.gov (United States)

    Seo, Keun Seok

    2016-01-01

    Staphylococcal enterotoxins (SEs) are unique bacterial toxins that cause gastrointestinal toxicity as well as superantigenic activity. Since systemic administration of SEs induces superantigenic activity leading to toxic shock syndrome that may mimic enterotoxic activity of SEs such as vomiting and diarrhea, oral administration of SEs in the monkey feeding assay is considered as a standard method to evaluate emetic activity of SEs. This chapter summarizes and discusses practical considerations of the monkey feeding assay used in studies characterizing classical and newly identified SEs.

  11. Thermal cycling tests of actively cooled beryllium copper joints

    Energy Technology Data Exchange (ETDEWEB)

    Roedig, M.; Duwe, R.; Linke, J.; Schuster, A.; Wiechers, B. [Forschungszentrum Juelich GmbH (Germany)

    1998-01-01

    Screening tests (steady state heating) and thermal fatigue tests with several kinds of beryllium-copper joints have been performed in an electron beam facility. Joining techniques under investigation were brazing with silver containing and silver-free braze materials, hot isostatic pressing (HIP) and diffusion bonding (hot pressing). Best thermal fatigue performance was found for the brazed samples. (author)

  12. Active Fault Detection Based on a Statistical Test

    DEFF Research Database (Denmark)

    Sekunda, André Krabdrup; Niemann, Hans Henrik; Poulsen, Niels Kjølstad

    2016-01-01

    In this paper active fault detection of closed loop systems using dual Youla-Jabr-Bongiorno-Kucera(YJBK) parameters is presented. Until now all detector design for active fault detection using the dual YJBK parameters has been based on CUSUM detectors. Here a method for design of a matched filter...

  13. Improving active Mealy machine learning for protocol conformance testing

    NARCIS (Netherlands)

    Aarts, F.; Kuppens, H.; Tretmans, J.; Vaandrager, F.; Verwer, S.

    2014-01-01

    Using a well-known industrial case study from the verification literature, the bounded retransmission protocol, we show how active learning can be used to establish the correctness of protocol implementation I relative to a given reference implementation R. Using active learning, we learn a model M

  14. Plutonium recycle test reactor characterization activities and results

    International Nuclear Information System (INIS)

    Cornwell, B.C.

    1997-01-01

    Report contains results of PRTR core and associated structures characterization performed in January and February of 1997. Radiation survey data are presented, along with recommendations for stabilization activities before transitioning to a decontamination and decommissioning function. Recommendations are also made about handling the waste generated by the stabilization activities, and actions suggested by the Decontamination and Decommissioning organization

  15. Manufacturing and thermomechanical testing of actively cooled all beryllium high heat flux test pieces

    International Nuclear Information System (INIS)

    Vasiliev, N.N.; Sokolov, Yu.A.; Shatalov, G.E.

    1995-01-01

    One of the problems affiliated to ITER high heat flux elements development is a problem of interface of beryllium protection with heat sink routinely made of copper alloys. To get rid of this problem all beryllium elements could be used as heat receivers in places of enhanced thermal loads. In accordance with this objectives four beryllium test pieces of two types have been manufactured in open-quotes Institute of Berylliumclose quotes for succeeding thermomechanical testing. Two of them were manufactured in accordance with JET team design; they are round open-quotes hypervapotron typeclose quotes test pieces. Another two ones are rectangular test sections with a twisted tape installed inside of the circular channel. Preliminary stress-strain analysis have been performed for both type of the test pieces. Hypervapotrons have been shipped to JET where they were tested on JET test bed. Thermomechanical testing of pieces of the type of open-quotes swirl tape inside of tubeclose quotes have been performed on Kurchatov Institute test bed. Chosen beryllium grade properties, some details of manufacturing, results of preliminary stress-strain analysis and thermomechanical testing of the test pieces open-quotes swirl tape inside of tubeclose quotes type are given in this report

  16. Proficiency Testing Activities of Frequency Calibration Laboratories in Taiwan, 2009

    Science.gov (United States)

    2009-11-01

    cht.com.tw Abstract In order to meet the requirements of ISO 17025 and the demand of TAF (Taiwan Accreditation Foundation) for calibration inter... IEC 17025 General requirements for the competence of testing and calibration laboratories. The proficiency testing results are then important...on-site evaluation, an assessment team is organized to examine the technical competence of the labs and their compliance with the requirements of ISO

  17. Solar Energy Education. Home economics: student activities. Field test edition

    Energy Technology Data Exchange (ETDEWEB)

    1981-03-01

    A view of solar energy from the standpoint of home economics is taken in this book of activities. Students are provided information on solar energy resources while performing these classroom activities. Instructions for the construction of a solar food dryer and a solar cooker are provided. Topics for study include window treatments, clothing, the history of solar energy, vitamins from the sun, and how to choose the correct solar home. (BCS)

  18. Hybrid and plug-in hybrid electric vehicle performance testing by the US Department of Energy Advanced Vehicle Testing Activity

    Science.gov (United States)

    Karner, Donald; Francfort, James

    The Advanced Vehicle Testing Activity (AVTA), part of the U.S. Department of Energy's FreedomCAR and Vehicle Technologies Program, has conducted testing of advanced technology vehicles since August 1995 in support of the AVTA goal to provide benchmark data for technology modeling, and vehicle development programs. The AVTA has tested full size electric vehicles, urban electric vehicles, neighborhood electric vehicles, and hydrogen internal combustion engine powered vehicles. Currently, the AVTA is conducting baseline performance, battery benchmark and fleet tests of hybrid electric vehicles (HEV) and plug-in hybrid electric vehicles (PHEV). Testing has included all HEVs produced by major automotive manufacturers and spans over 2.5 million test miles. Testing is currently incorporating PHEVs from four different vehicle converters. The results of all testing are posted on the AVTA web page maintained by the Idaho National Laboratory.

  19. TESTING GUIDELINES FOR TECHNETIUM-99 ADSORPTION ON ACTIVATED CARBON

    International Nuclear Information System (INIS)

    Byrnes, M.E.

    2010-01-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs) will

  20. TESTING GUIDELINES FOR TECHNETIUM-99 ABSORPTION ON ACTIVATED CARBON

    Energy Technology Data Exchange (ETDEWEB)

    BYRNES ME

    2010-09-08

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs

  1. Risk-informed inservice test activities at the NRC

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, D.; Cheok, M.; Hsia, A.

    1996-12-01

    The operational readiness of certain safety-related components is vital to the safe operation of nuclear power plants. Inservice testing (IST) is one of the mechanisms used by licensees to ensure this readiness. In the past, the type and frequency of IST have been based on the collective best judgment of the NRC and industry in an ASME Code consensus process and NRC rulemaking process. Furthermore, IST requirements have not explicitly considered unique component and system designs and contribution to overall plant risk. Because of the general nature of ASME Code test requirements and non-reliance on risk estimates, current IST requirements may not adequately emphasize testing those components that are most important to safety and may overly emphasize testing of less safety significant components. Nuclear power plant licensees are currently interested in optimizing testing by applying resources in more safety significant areas and, where appropriate, reducing measures in less safety-significant areas. They are interested in maintaining system availability and reducing overall maintenance costs in ways that do not adversely affect safety. The NRC has been interested in using probabilistic, as an adjunct to deterministic, techniques to help define the scope, type and frequency of IST. The development of risk-informed IST programs has the potential to optimize the use of NRC and industry resources without adverse affect on safety.

  2. Deep Borehole Field Test Research Activities at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    Dobson, Patrick [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tsang, Chin-Fu [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kneafsey, Timothy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Borglin, Sharon [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piceno, Yvette [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Andersen, Gary [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nakagawa, Seiji [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nihei, Kurt [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rutqvist, Jonny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Doughty, Christine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Reagan, Matthew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-19

    The goal of the U.S. Department of Energy Used Fuel Disposition’s (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterized by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.

  3. Risk-informed inservice test activities at the NRC

    International Nuclear Information System (INIS)

    Fischer, D.; Cheok, M.; Hsia, A.

    1996-01-01

    The operational readiness of certain safety-related components is vital to the safe operation of nuclear power plants. Inservice testing (IST) is one of the mechanisms used by licensees to ensure this readiness. In the past, the type and frequency of IST have been based on the collective best judgment of the NRC and industry in an ASME Code consensus process and NRC rulemaking process. Furthermore, IST requirements have not explicitly considered unique component and system designs and contribution to overall plant risk. Because of the general nature of ASME Code test requirements and non-reliance on risk estimates, current IST requirements may not adequately emphasize testing those components that are most important to safety and may overly emphasize testing of less safety significant components. Nuclear power plant licensees are currently interested in optimizing testing by applying resources in more safety significant areas and, where appropriate, reducing measures in less safety-significant areas. They are interested in maintaining system availability and reducing overall maintenance costs in ways that do not adversely affect safety. The NRC has been interested in using probabilistic, as an adjunct to deterministic, techniques to help define the scope, type and frequency of IST. The development of risk-informed IST programs has the potential to optimize the use of NRC and industry resources without adverse affect on safety

  4. Deep Borehole Field Test Research Activities at LBNL

    International Nuclear Information System (INIS)

    Dobson, Patrick; Tsang, Chin-Fu; Kneafsey, Timothy; Borglin, Sharon; Piceno, Yvette; Andersen, Gary; Nakagawa, Seiji; Nihei, Kurt; Rutqvist, Jonny; Doughty, Christine; Reagan, Matthew

    2016-01-01

    The goal of the U.S. Department of Energy Used Fuel Disposition's (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterized by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.

  5. Role of human neurobehavioural tests in regulatory activity on chemicals

    Science.gov (United States)

    Stephens, R.; Barker, P.

    1998-01-01

    Psychological performance tests have been used since the mid-1960s in occupational and environmental health toxicology. The interpretation of significantly different test scores in neurobehavioural studies is not straightforward in the regulation of chemicals. This paper sets out some issues which emerged from discussions at an international workshop, organised by the United Kingdom Health and Safety Executive (HSE), to discuss differences in interpretation of human neurobehavioural test data in regulatory risk assessments. The difficulties encountered by regulators confronted with neurobehavioural studies seem to be twofold; some studies lack scientific rigor; other studies, although scientifically sound, are problematic because it is not clear what interpretation to place on the results. Issues relating to each of these points are discussed. Next, scenarios within which to consider the outcomes of neurobehavioural studies are presented. Finally, conclusions and recommendations for further work are put forward.   PMID:9624273

  6. Wind Tunnel Testing of Active Control System for Bridges

    DEFF Research Database (Denmark)

    Hansen, Henriette I.; Thoft-Christensen, Palle

    This paper describes preparation of wind tunnel testing of the principle of using flaps to control the motion of suspension bridges. The experiment will take place at the Instituto Superior Technico Lisbon, Portugal. The bridge section model is constructed of foam with an aluminium frame. The flaps...... are regulated by servo motors. Neural networks are used to position the flaps in the optimal positions....

  7. Active Match Load Circuit Intended for Testing Piezoelectric Transformers

    DEFF Research Database (Denmark)

    Andersen, Thomas; Rødgaard, Martin Schøler; Andersen, Michael A. E.

    2012-01-01

    An adjustable high voltage active load circuit for voltage amplitudes above 100 volts, especially intended for resistive matching the output impedance of a piezoelectric transformer (PT) is proposed in this paper. PTs have been around for over 50 years, were C. A. Rosen is common known for his...

  8. Conclusions from fire tests in activated carbon filled adsorbers

    International Nuclear Information System (INIS)

    Mathewes, W.

    1987-01-01

    Activated carbons as used in gas-phase adsorption may be subjected to heating, either from heat applied externally to the carbon bed, or heat generated by radioactive contaminants, or by the adsorption process itself. This report presents results of artificially ignited beds of activated carbon. This report also considers results concerning the self-ignition of non-contaminated carbon and such of solvent-contaminated carbon subjected to external heating in beds with an air flow and in beds without an air flow. An estimation is given for the heat generation caused by radioactive contaminants as well as by the adsorption process. Studies of handling of endangered components and studies of alarm indicating systems give guidance for the contemporary lay-out and design

  9. Hanford Immobilized Low-Activity Waste Product Acceptance Test Plan

    International Nuclear Information System (INIS)

    Peeler, D.

    1999-01-01

    'The Hanford Site has been used to produce nuclear materials for the U.S. Department of Energy (DOE) and its predecessors. A large inventory of radioactive and mixed waste, largely generated during Pu production, exists in 177 underground single- and double-shell tanks. These wastes are to be retrieved and separated into low-activity waste (LAW) and high-level waste (HLW) fractions. The DOE is proceeding with an approach to privatize the treatment and immobilization of Handord''s LAW and HLW.'

  10. Development of Active Flutter Suppression Wind Tunnel Testing Technology

    Science.gov (United States)

    1975-01-01

    inch stainless steel precision haft ng out to the aileron surfaces. Torque was then transmitted aft through another crank-pushrod linkage...NMMltetiM Clllir llllisi Sl> ptT »I»" CmrN StiiiH tli!ii<ti> »ir|wu ŗK kUfej •*! AFFDL-TR-74-126 o 00 DEVELOPMENT OF ACTIVE FLUTTER...Installations . . 28 14. Outboard Aileron Installation 30 15. Airplane FMCS Block Diagram 35 16. Model FMCS Block Diagram 36 17. Model FMCS

  11. Hanford Immobilized Low-Activity Waste Product Acceptance Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Peeler, D.

    1999-06-22

    'The Hanford Site has been used to produce nuclear materials for the U.S. Department of Energy (DOE) and its predecessors. A large inventory of radioactive and mixed waste, largely generated during Pu production, exists in 177 underground single- and double-shell tanks. These wastes are to be retrieved and separated into low-activity waste (LAW) and high-level waste (HLW) fractions. The DOE is proceeding with an approach to privatize the treatment and immobilization of Handord''s LAW and HLW.'

  12. Further evaluation of the CSNI separate effect test activity

    Energy Technology Data Exchange (ETDEWEB)

    D`Auria, F.; Aksan, S.N.; Glaeser, H. [and others

    1995-09-01

    An internationally agreed Separate Effect Test (SET) Validation Matrix for the thermalhydraulic system codes has been established by a subgroup of the Task Group on Thermalhydraulic System Behaviour as requested by OECD/NEA Committee on the Safety of Nuclear Installations (CSNI) Principal Working Group No. 2 on Coolant System Behavior. The construction of such matrix constituted an attempt to collect together in a systematic way the best sets of openly available test data to select for code validation. As a final result, 67 phenomena have been identified and characterized, roughly 200 facilities have been considered and more than 1000 experiments have been selected as useful for the validation of the codes. The objective of the present paper is to provide additional evaluation of the obtained data base and to supply an a-posteriori judgement in relation to (a) the data base adequacy, (b) the phenomenon, and (c) the need for additional experiments. This has been provided independently by each of the authors. The main conclusions are that large amount of data are available for certain popular phenomena e.g. heat transfer, but data are severely lacking in more esoteric areas e.g. for characterizing phenomena such as parallel channel instability and boron mixing and transport.

  13. Characterization of strain rate sensitivity and activation volume using the indentation relaxation test

    International Nuclear Information System (INIS)

    Xu Baoxing; Chen Xi; Yue Zhufeng

    2010-01-01

    We present the possibility of extracting the strain rate sensitivity, activation volume and Helmholtz free energy (for dislocation activation) using just one indentation stress relaxation test, and the approach is demonstrated with polycrystalline copper. The Helmholtz free energy measured from indentation relaxation agrees well with that from the conventional compression relaxation test, which validates the proposed approach. From the indentation relaxation test, the measured indentation strain rate sensitivity exponent is found to be slightly larger, and the indentation activation volume much smaller, than their counterparts from the compression test. The results indicate the involvement of multiple dislocation mechanisms in the indentation test.

  14. Modeling motive activation in the Operant Motives Test

    DEFF Research Database (Denmark)

    Runge, J. Malte; Lang, Jonas W. B.; Engeser, Stefan

    2016-01-01

    The Operant Motive Test (OMT) is a picture-based procedure that asks respondents to generate imaginative verbal behavior that is later coded for the presence of affiliation, power, and achievement-related motive content by trained coders. The OMT uses a larger number of pictures and asks...... on the dynamic model were .52, .62, and .73 for the affiliation, achievement, and power motive in the OMT, respectively. The second contribution of this article is a tutorial and R code that allows researchers to directly apply the dynamic Thurstonian IRT model to their data. The future use of the OMT...... respondents to provide more brief answers than earlier and more traditional picture-based implicit motive measures and has therefore become a frequently used measurement instrument in both research and practice. This article focuses on the psychometric response mechanism in the OMT and builds on recent...

  15. A new impedance based approach to test the activity of recombinant protein--Semaphorins as a test case.

    Science.gov (United States)

    Birger, Anastasya; Besser, Elazar; Reubinoff, Benjamin; Behar, Oded

    2015-10-01

    The biological activity of a recombinant protein is routinely measured using a bioassay such as an enzyme assay. However, many proteins have no enzymatic activity and in many cases it is difficult to devise a simple and reliable approach to test their activity. Semaphorins, Ephrins, Slits, Netrins or amylin-assisted proteins have numerous activities affecting many systems and cell types in the human body. Most of them are also able to induce rapid cytoskeleton changes at least in some cell types. We assumed therefore, that such proteins might be tested based on their ability to modulate the cytoskeleton. Here we tested a number of semaphorins in an impedance based label-free platform that allows for dynamic monitoring of subtle morphological and adhesive changes. This system has proved to be a very fast, sensitive and effective way to monitor and determine the activity of such proteins. Furthermore we showed that it is possible to customize a cell-protein system by transfecting the cells with specific receptors and test the cell response following the addition of the recombinant ligand protein. Since other protein families such as Ephrins and Netrins can also influence the cytoskeleton of some cells, this approach may be applicable to a large number of proteins. Copyright © 2015 Elsevier GmbH. All rights reserved.

  16. Recovery efficiency test project, Phase 2 activity report

    Energy Technology Data Exchange (ETDEWEB)

    Overbey, W.K. Jr.; Salamy, S.P.; Locke, C.D.

    1989-02-01

    The Recovery Efficiency Test well project addressed a number of technical issues. The primary objective was to determine the increased efficiency of gas recovery of a long horizontal wellbore over that of a vertical wellbore and, more specifically, what improvements can be expected from inducing multiple hydraulic fractures from such a wellbore. This volume contains appendices for: (1) supporting material and procedures for data frac'' stimulation of zone 6 using nitrogen and nitrogen foam; (2) supporting material and procedures for stimulation no. 1 nitrogen gas frac on zone no. 1; (3) supporting material and procedures for stimulation no. 2 in zone no. 1 using liquid CO{sub 2}; (4) supporting material and procedures for frac no. 3 on zone no.1 using nitrogen foam and proppant; (5) supporting material and procedures for stimulation no. 4 in zones 2--3 and 4 using nitrogen foam and proppant; (6) supporting materials and procedures for stimulation no. 5 in zones 5 and 8; and (7) fracture diagnostics reports and supporting materials.

  17. Development and Test of Robotically Assisted Extravehicular Activity Gloves

    Science.gov (United States)

    Rogers, Jonathan M.; Peters, Benjamin J.; Laske, Evan A.; McBryan, Emily R.

    2017-01-01

    Over the past two years, the High Performance EVA Glove (HPEG) project under NASA's Space Technology Mission Directorate (STMD) funded an effort to develop an electromechanically-assisted space suit glove. The project was a collaboration between the Johnson Space Center's Software, Robotics, and Simulation Division and the Crew and Thermal Systems division. The project sought to combine finger actuator technology developed for Robonaut 2 with the softgoods from the ILC Phase VI EVA glove. The Space Suit RoboGlove (SSRG) uses a system of three linear actuators to pull synthetic tendons attached to the glove's fingers to augment flexion of the user's fingers. To detect the user's inputs, the system utilizes a combination of string potentiometers along the back of the fingers and force sensitive resistors integrated into the fingertips of the glove cover layer. This paper discusses the development process from initial concepts through two major phases of prototypes, and the results of initial human testing. Initial work on the project focused on creating a functioning proof of concept, designing the softgoods integration, and demonstrating augmented grip strength with the actuators. The second year of the project focused on upgrading the actuators, sensors, and software with the overall goal of creating a system that moves with the user's fingers in order to reduce fatigue associated with the operation of a pressurized glove system. This paper also discusses considerations for a flight system based on this prototype development and address where further work is required to mature the technology.

  18. Fitness Testing in Physical Education--A Misdirected Effort in Promoting Healthy Lifestyles and Physical Activity?

    Science.gov (United States)

    Cale, Lorraine; Harris, Jo

    2009-01-01

    Background: Physical fitness testing is commonplace within schools and the physical education (PE) curriculum, with advocates claiming one of the key purposes of testing to be the promotion of healthy lifestyles and physical activity. Despite this, much controversy has surrounded the fitness testing of young people. Purpose: This paper draws on…

  19. Application of the IEAF-2001 activation data library to activation analyses of the IFMIF high flux test module

    International Nuclear Information System (INIS)

    Fischer, U.; Wilson, P.P.H.; Leichtle, D.; Simakov, S.P.; Moellendorff, U. von; Konobeev, A.; Korovin, Yu.; Pereslavtsev, P.; Schmuck, I.

    2002-01-01

    A complete activation data library IEAF-2001 (intermediate energy activation file) has been developed in standard ENDF-6 format with neutron-induced activation cross sections for 679 target nuclides from Z=1 (hydrogen) to Z=84 (polonium) and incident neutron energies up to 150 MeV. Using the NJOY processing code, an IEAF-2001 working library has been prepared in a 256 energy group structure for enabling activation analyses of the International Fusion Material Irradiation Facility (IFMIF) D-Li neutron source. This library was applied to the activation analysis of the IFMIF high flux test module using the recent Analytical and Laplacian Adaptive Radioactivity Analysis activation code which is capable of handling the variety of reaction channels open in the energy domain above 20 MeV. The IEAF-2001 activation library was thus shown to be suitable for activation analyses in fusion technology and intermediate energy applications such as the IFMIF D-Li neutron source

  20. Development and Testing of the Observational System for Recording Physical Activity in Children: Elementary School

    Science.gov (United States)

    McIver, Kerry L.; Brown, William H.; Pfeiffer, Karin A.; Dowda, Marsha; Pate, Russell R.

    2016-01-01

    Purpose: This study describes the development and pilot testing of the Observational System for Recording Physical Activity-Elementary School (OSRAC-E) Version. Method: This system was developed to observe and document the levels and types of physical activity and physical and social contexts of physical activity in elementary school students…

  1. Activity-Guided Isolation of Bioactive Constituents with Antinociceptive Activity from Muntingia calabura L. Leaves Using the Formalin Test

    Directory of Open Access Journals (Sweden)

    Mohd. Izwan Mohamad Yusof

    2013-01-01

    Full Text Available The present study was conducted to determine the antinociceptive potential of methanol extract of Muntingia calabura L. (MEMC and to isolate and identify the bioactive compound(s responsible for the observed antinociceptive activity. The MEMC and its partitions (petroleum ether (PEP, ethyl acetate (EAP, and aqueous (AQP partitions, in the dose range of 100, 500, and 1000 mg/kg, were tested using the formalin-induced nociceptive test. The PEP, which exerted the most effective activity in the respective early and late phase, was further subjected to the fractionation procedures and yielded seven fractions (labelled A to G. These fractions were tested, at the dose of 300 mg/kg, together with distilled water or 10% DMSO (negative controls; morphine and aspirin (positive controls for potential antinociceptive activity. Of all fractions, Fraction D showed the most significant antinociceptive activity, which is considered as equieffective to morphine or aspirin in the early or late phase, respectively. Further isolation and identification processes on fraction D led to the identification of three known and one new compounds, namely, 5-hydroxy-3,7,8-trimethoxyflavone (1, 3,7-dimethoxy-5-hydroyflavone (2, 2′,4′-dihydroxy-3′-methoxychalcone (3, and calaburone (4. At the dose of 50 mg/kg, compound 3 exhibited the highest percentage of antinociceptive activity in both phases of the formalin test. In conclusion, the antinociceptive activity of MEMC involved, partly, the synergistic activation of the flavonoid types of compounds.

  2. The performance test of NAA laboratory at radionuclide measure with low activity

    International Nuclear Information System (INIS)

    Sri Murniasih; Sukirno

    2016-01-01

    The performance test to measure the I-131 radionuclide activity has been carried out at CAST-NAA laboratory. The purpose of this activity is to know the performance of a laboratory in the testing of low radioactivity sample. The tested sample consists of the form I-131 radionuclide sources shaped thin plastic disk with a certain weight. Evaluation of laboratory performance test results carried out by the organizer of the program test appeal (PTKMR-BATAN). Evaluation results showed that testing of point source of the I-131 radionuclide with comparative method gives a good enough results with errors below 10%. The results of the performance test evaluation are useful as the external quality control to a testing method that is expected in NAA laboratory. (author)

  3. Comparison of sensitivity of quantiferon-tb gold test and tuberculin skin test in active pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Khalil, K.F.; Ambreen, A.; Butt, T.

    2013-01-01

    Objective: To compare the sensitivity of tuberculin skin test (TST) and quantiFERON-TB gold test (QFT-G) in active pulmonary tuberculosis. Study Design: Analytical study. Place and Duration of Study: Department of Pulmonology, Fauji Foundation Hospital, Rawalpindi, from July 2011 to January 2012. Methodology: QuantiFERON-TB gold test (QFT-G) was evaluated and compared it with tuberculin skin test (TST) in 50 cases of active pulmonary tuberculosis, in whom tuberculous infection was suspected on clinical, radiological and microbiological grounds. Sensitivity was determined against positive growth for Mycobacterium tuberculosis. Results: Out of 50 cases, 43 were females and 7 were males. The mean age was 41.84 A+- 19.03 years. Sensitivity of QFT-G was 80% while that of TST was 28%. Conclusion: QFT-G has much higher sensitivity than TST for active pulmonary tuberculosis. It is unaffected by prior BCG administration and prior exposure to atypical mycobacteria. A positive QFT-G result can be an adjunct to diagnosis in patients having clinical and radiological data compatible with pulmonary tuberculosis. (author)

  4. Determination of Importance Evaluation for Exploratory Studies Facility (ESF) Subsurface Testing Activities

    International Nuclear Information System (INIS)

    C.J. Byrne

    2001-01-01

    This Determination of Importance Evaluation (DIE) applies to the Subsurface Exploratory Studies Facility (ESF), encompassing the Topopah Spring (TS) Loop from Station 0+00 meters (m) at the North Portal to breakthrough at the South Portal (approximately 78+77 m), and ancillary test and operation support areas including the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. This evaluation applies specifically to site characterization testing activities ongoing and planned in the Subsurface ESF. ESF site characterization activities are being performed to obtain the information necessary to determine whether the Yucca Mountain Site is suitable as a geologic repository for spent nuclear fuel and high-level radioactive waste. A more detailed description of these testing activities is provided in Section 6 of this DIE. Generally, the construction and operation of excavations associated with these testing activities are evaluated in the DIE for the Subsurface ESF (CRWMS M and O 1999a) and the DIE for the ESF ECRB Cross Drift (CRWMS M and O 2000a). The scope of this DIE also entails the proposed Unsaturated Zone (UZ) Transport Test at Busted Butte. Although, not a part of the TS Loop or ECRB Cross Drift, the associated testing activities are Subsurface testing activities. Busted Butte is located to the south south-east of the TS Loop and is outside the Conceptual Controlled Area Boundary (CCAB). These activities provide access to the Calico Hills (CH) geologic structure. In the case of Busted Butte, construction and operation of excavations are evaluated herein (since this activity was not previously evaluated in CRWMS M and O 1999a). The objectives of this DIE are to determine whether Subsurface ESF testing, and associated activities, could potentially impact site characterization testing and/or the waste isolation capabilities of the site. Controls needed to limit any potential impacts are identified in Section 13. The validity and veracity of the

  5. Determination of Importance Evaluation for Exploratory Studies Facility (ESF) Subsurface Testing Activities

    Energy Technology Data Exchange (ETDEWEB)

    C.J. Byrne

    2001-02-20

    This Determination of Importance Evaluation (DIE) applies to the Subsurface Exploratory Studies Facility (ESF), encompassing the Topopah Spring (TS) Loop from Station 0+00 meters (m) at the North Portal to breakthrough at the South Portal (approximately 78+77 m), and ancillary test and operation support areas including the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. This evaluation applies specifically to site characterization testing activities ongoing and planned in the Subsurface ESF. ESF site characterization activities are being performed to obtain the information necessary to determine whether the Yucca Mountain Site is suitable as a geologic repository for spent nuclear fuel and high-level radioactive waste. A more detailed description of these testing activities is provided in Section 6 of this DIE. Generally, the construction and operation of excavations associated with these testing activities are evaluated in the DIE for the Subsurface ESF (CRWMS M&O 1999a) and the DIE for the ESF ECRB Cross Drift (CRWMS M&O 2000a). The scope of this DIE also entails the proposed Unsaturated Zone (UZ) Transport Test at Busted Butte. Although, not a part of the TS Loop or ECRB Cross Drift, the associated testing activities are Subsurface testing activities. Busted Butte is located to the south south-east of the TS Loop and is outside the Conceptual Controlled Area Boundary (CCAB). These activities provide access to the Calico Hills (CH) geologic structure. In the case of Busted Butte, construction and operation of excavations are evaluated herein (since this activity was not previously evaluated in CRWMS M&O 1999a). The objectives of this DIE are to determine whether Subsurface ESF testing, and associated activities, could potentially impact site characterization testing and/or the waste isolation capabilities of the site. Controls needed to limit any potential impacts are identified in Section 13. The validity and veracity of the individual

  6. Determination of Importance Evaluation for Exploratory Studies Facility (ESF) Subsurface Testing Activities

    International Nuclear Information System (INIS)

    Goodin, S.

    2002-01-01

    This Determination of Importance Evaluation (DIE) applies to the Subsurface Exploratory Studies Facility (ESF), encompassing the Topopah Spring (TS) Loop from Station 0+00 meters (m) at the North Portal to breakthrough at the South Portal (approximately 78+77 m), and ancillary test and operation support areas including the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. This evaluation applies specifically to site characterization testing activities ongoing and planned in the Subsurface ESF. ESF site characterization activities are being performed to obtain the information necessary to determine whether the Yucca Mountain Site is suitable as a geologic repository for spent nuclear fuel and high-level radioactive waste. A more detailed description of these testing activities is provided in Section 6 of this DIE. Generally, the construction and operation of excavations associated with these testing activities are evaluated in the DIE for the Subsurface ESF (CRWMS M andO 1999a) and the DIE for the ESF ECRB Cross Drift (CRWMS M andO 2000a). The scope of this DIE also entails the proposed Unsaturated Zone (UZ) Transport Test at Busted Butte. Although, not a part of the TS Loop or ECRB Cross Drift, the associated testing activities are Subsurface testing activities. Busted Butte is located to the south south-east of the TS Loop and is outside the Conceptual Controlled Area Boundary (CCAB). These activities provide access to the Calico Hills (CH) geologic structure. In the case of Busted Butte, construction and operation of excavations are evaluated herein (since this activity was not previously evaluated in CRWMS M andO 1999a). The objectives of this DIE are to determine whether Subsurface ESF testing, and associated activities, could potentially impact site characterization testing and/or the waste isolation capabilities of the site. Controls needed to limit any potential impacts are identified in Section 13. The validity and veracity of the

  7. Are students' impressions of improved learning through active learning methods reflected by improved test scores?

    Science.gov (United States)

    Everly, Marcee C

    2013-02-01

    To report the transformation from lecture to more active learning methods in a maternity nursing course and to evaluate whether student perception of improved learning through active-learning methods is supported by improved test scores. The process of transforming a course into an active-learning model of teaching is described. A voluntary mid-semester survey for student acceptance of the new teaching method was conducted. Course examination results, from both a standardized exam and a cumulative final exam, among students who received lecture in the classroom and students who had active learning activities in the classroom were compared. Active learning activities were very acceptable to students. The majority of students reported learning more from having active-learning activities in the classroom rather than lecture-only and this belief was supported by improved test scores. Students who had active learning activities in the classroom scored significantly higher on a standardized assessment test than students who received lecture only. The findings support the use of student reflection to evaluate the effectiveness of active-learning methods and help validate the use of student reflection of improved learning in other research projects. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Results of Active Test of Uranium-Plutonium Co-denitration Facility at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Numao, Teruhiko; Nakayashiki, Hiroshi; Arai, Nobuyuki; Miura, Susumu; Takahashi, Yoshiharu; Nakamura, Hironobu; Tanaka, Izumi

    2007-01-01

    In the U-Pu co-denitration facility at Rokkasho Reprocessing Plant (RRP), Active Test which composes of 5 steps was performed by using uranium-plutonium nitrate solution that was extracted from spent fuels. During Active Test, two kinds of tests were performed in parallel. One was denitration performance test in denitration ovens, and expected results were successfully obtained. The other was validation and calibration of non-destructive assay (NDA) systems, and expected performances were obtained and their effectiveness as material accountancy and safeguards system was validated. (authors)

  9. Test of active coal capacity for retaining gaseous effluents contaminated by 131 I

    International Nuclear Information System (INIS)

    Campeanu, Catalina; Cruceru, Madalina; Neacsu, Elena

    1999-01-01

    The aim of this paper is to test the retaining capacity of the active coal of the filters for gaseous effluents contaminated by 131 I. The active coal filters are design for equipping ventilation installations of nuclear plants in which radioactive iodine and combination of it were produced and handled. Such active coal filters are provided also to sorbonnes for radiochemical and physical handling of radioactive iodine. Testing the retaining capacity of active coal for filters is an obvious step, particularly, when the material was stored long time after preparation

  10. Manufacturing and testing of actively cooled test limiters for TEXTOR made of the brazed joint SEPCARB-N11/TZM

    International Nuclear Information System (INIS)

    Hohenauer, W.; Bolt, H.; Koppitz, T.; Linke, J.; Lison, R.; You, J.H.; Nickel, H.

    1998-01-01

    To investigate the erosion and redepositon phenomena of fusion-related materials under stationary conditions, actively cooled test limiters were developed for TEXTOR (Tokamak Experiment for Technology Orientated Research). They allow experiments under stationary conditions within the plasma pulse length of 10 s. Heat loads of typically 10 MW m<-2 are removed by pressurised water: volume flow is 10 m 3 h -1, pressure 15 bar and the minimum coefficient of heat transfer is about 75000 W m-2 K. Prototype limiters were built as brazed composites of a C/C material (SEPCARB-N11) and a TZM substrate. The samples were successfully tested in screening tests in the ion beam facility MARION (Material Research Ion Beam Test Facility) with hydrogen beams. Maximum heat loads of up to 22 MW m<-2 were applied without any failure of the cooling system. Steady state of the surface temperature was measured within 5 s. An advanced brazing technique enabled the joining of hemispherically shaped C/C shells to a TZM heat sink without failure. An optimised test limiter was tested in TEXTOR. Analytical and numerical models describing the effects of the heat load distribution, spatial temperatures and stresses were experimentally verified. (orig.)

  11. Monocyte Activation in Immunopathology: Cellular Test for Development of Diagnostics and Therapy

    Directory of Open Access Journals (Sweden)

    Ekaterina A. Ivanova

    2016-01-01

    Full Text Available Several highly prevalent human diseases are associated with immunopathology. Alterations in the immune system are found in such life-threatening disorders as cancer and atherosclerosis. Monocyte activation followed by macrophage polarization is an important step in normal immune response to pathogens and other relevant stimuli. Depending on the nature of the activation signal, macrophages can acquire pro- or anti-inflammatory phenotypes that are characterized by the expression of distinct patterns of secreted cytokines and surface antigens. This process is disturbed in immunopathologies resulting in abnormal monocyte activation and/or bias of macrophage polarization towards one or the other phenotype. Such alterations could be used as important diagnostic markers and also as possible targets for the development of immunomodulating therapy. Recently developed cellular tests are designed to analyze the phenotype and activity of living cells circulating in patient’s bloodstream. Monocyte/macrophage activation test is a successful example of cellular test relevant for atherosclerosis and oncopathology. This test demonstrated changes in macrophage activation in subclinical atherosclerosis and breast cancer and could also be used for screening a panel of natural agents with immunomodulatory activity. Further development of cellular tests will allow broadening the scope of their clinical implication. Such tests may become useful tools for drug research and therapy optimization.

  12. High-efficiency particulate air filter test activities at the Department of Energy

    International Nuclear Information System (INIS)

    Bresson, J.F.

    1987-01-01

    For the past 2 years, test activities at the three Department of Energy HEPA Filter Test Facilities (FTFs) have been conducted under a unified set of operating standards intended to help achieve consistency in test methods and test results. Reviews of test operations are conducted at each FTF annually, and technical support and guidance are provided on request. Round Robin tests are conducted twice a year to compare penetration and resistance test results among the three FTFs. The FTFs prepare summary test data twice a year, and the data is analyzed for trends with respect to ongoing quality of HEPA filters in nuclear facilities. Data and conclusions from both the Round Robin tests and semiannual reports are discussed, the latter without reference to specific manufacturers. The new DOE standards include provisions for consideration and approval of new test aerosols or test methods, under closely controlled change procedures. Progress in obtaining DOE approval for DOS as a new aerosol, and for the Alternative Test System (ATS) developed by, and reported on by the LANL, as an approved new test method are discussed, as are 2 significant changes in standard NE-F-3-43, related to (a) toxicology test alternatives, and (b) the test aerosol definition. Finally, the emergence of new, higher flow rated HEPA filters and Ultra Low Particulate Air (ULPA) filters will impact DOE's design, procurement, testing and use of HEPA filters in the near future

  13. Which is preferable for orthostatic hypotension diagnosis in older adults: active standing test or head-up tilt table test?

    Science.gov (United States)

    Aydin, Ali Ekrem; Soysal, Pinar; Isik, Ahmet Turan

    2017-01-01

    Correct evaluation of orthostatic hypotension (OH) is crucial in geriatric practice, since OH is associated with mortality and morbidity. The study aimed to determine the most appropriate method for measuring blood pressure in transition from supine to upright position in order to diagnose OH in older adults. Active standing test (AST) and head-up tilt table (HUT) test as well as comprehensive geriatric assessment (CGA), including mini-mental state examination or the cognitive state test, mini-nutritional assessment, basic and instrumental activities of daily living, and Tinetti performance-oriented mobility assessment indexes, were performed in 290 geriatric patients. The prevalence of OH during HUT and AST was 19% and 37%, respectively. In patients with OH during HUT, the frequency of dementia and recurrent falls were higher ( P 0.05). Comparison of the groups according to CGA measurements revealed significant differences in terms of cognition, nutritional status, activities of daily life, and balance function in patients with OH only during HUT ( P 0.05). The sensitivity, specificity, positive predictive value, and negative predictive values of AST were 49.0%, 65.5%, 25.0%, and 84.6% respectively, according to HUT. The results suggest that orthostatic blood pressure changes determined by HUT might be of higher clinical significance than that by AST in older adults. It might be important that the evaluation of OH by HUT should be included in daily geriatric practice.

  14. Electromyographic study of rotator cuff muscle activity during full and empty can tests

    Directory of Open Access Journals (Sweden)

    Yoshihiro Kai

    2015-01-01

    Full Text Available The empty can (EC and full can (FC tests are used as diagnostic tools for patients with rotator cuff disease. However, recently concerns have been raised that these tests do not selectively activate the muscle. Therefore, the purpose of this study was to evaluate the rotator cuff muscle activation levels during the EC and FC tests in various positions using electromyography. Twelve healthy, right-handed men without shoulder complaints (mean age: 26.1 years, range: 23–35 years were included. The tests were performed isometrically with the shoulder elevated at 45° and 90° in the sagittal, scapular, and coronal planes, either in the thumb-up (FC test or thumb-down (EC test positions. During these positions, the electromyographic signal was recorded simultaneously from the four shoulder muscles using a combination of surface and intramuscular fine-wire electrodes. The average activation of the supraspinatus and subscapularis was greater during the EC test than during the FC test and in the scapular and coronal planes than in the sagittal plane at 90°. For the infraspinatus, there were no significant differences in any positions between the two tests. Thus, the rotator cuff muscles are influenced by arm position and the elevation plane during the EC and FC tests.

  15. Can disc diffusion susceptibility tests assess the antimicrobial activity of engineered nanoparticles?

    NARCIS (Netherlands)

    Kourmouli, A.; Valenti, M.; van Rijn, E.; Beaumont, H.J.E.; Kalantzi, Olga Ioanna; Schmidt-Ott, A.; Biskos, G.

    2018-01-01

    The use of disc diffusion susceptibility tests to determine the antibacterial activity of engineered nanoparticles (ENPs) is questionable because their low diffusivity practically prevents them from penetrating through the culture media. In this study, we investigate the ability of such a test,

  16. An overview of Test Techniques for Characterizing Active Phased Array Antennas

    NARCIS (Netherlands)

    Keizer, W.P.M.N.

    1999-01-01

    In this paper a review will be given of the microwave testing of active phased anay antennas. It will be shown that due to the application of Transmit/Receive (T/R) modules in such antennas considerable more tests have to be performed to characterise completely their microwave performance than for

  17. Test-Retest Reliability of a Survey to Measure Transport-Related Physical Activity in Adults

    Science.gov (United States)

    Badland, Hannah; Schofield, Grant

    2006-01-01

    The present research details test-retest reliability of a newly developed, telephone-administered TPA survey for adults. This instrument examines barriers, perceptions, and current travel behaviors to place of work/study and local convenience shops. Demonstrated test-retest reliability of the Active Friendly Environments-Transport-Related Physical…

  18. 78 FR 34047 - Takes of Marine Mammals Incidental to Specified Activities; Navy Research, Development, Test and...

    Science.gov (United States)

    2013-06-06

    ... levels for these animals may be estimated using TTS data from marine mammals and relationships between... Marine Mammals Incidental to Specified Activities; Navy Research, Development, Test and Evaluation Activities at the Naval Surface Warfare Center Panama City Division AGENCY: National Marine Fisheries Service...

  19. 78 FR 47282 - Takes of Marine Mammals Incidental to Specified Activities; Navy Research, Development, Test and...

    Science.gov (United States)

    2013-08-05

    ..., and location) and marine mammal and/or indicator presence, species, number of animals, their behavior... Marine Mammals Incidental to Specified Activities; Navy Research, Development, Test and Evaluation Activities at the Naval Surface Warfare Center Panama City Division AGENCY: National Marine Fisheries Service...

  20. Protocols to test the activity of antimicrobial peptides against the honey bee pathogen Paenibacillus larvae.

    Science.gov (United States)

    Khilnani, Jasmin C; Wing, Helen J

    2015-10-01

    Paenibacillus larvae is the causal agent of the honey bee disease American Foulbrood. Two enhanced protocols that allow the activity of antimicrobial peptides to be tested against P. larvae are presented. Proof of principle experiments demonstrate that the honey bee antimicrobial peptide defensin 1 is active in both assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Activity of two strobilurin fungicides against three species of decay fungi in agar plate tests

    Science.gov (United States)

    Juliet D. Tang; Tina Ciaramitaro; Maria Tomaso-Peterson; Susan V. Diehl

    2017-01-01

    The objective of this study was to examine the toxicity of strobilurin fungicides against wood decay fungi in order to assess their potential to act as a co-biocide for copper-based wood protection. Two strobilurin fungicides, Heritage (50% azoxystrobin active ingredient) and Insignia (20% pyraclostrobin active ingredients), and copper sulfate pentahydrate were tested...

  2. Developmental toxicity of thyroid-active compounds in a zebrafish embryotoxicity test

    NARCIS (Netherlands)

    Jomaa, B.; Hermsen, S.A.B.; Kessels, M.Y.; Berg, van den J.H.J.; Peijenburg, A.C.M.; Aarts, J.M.M.J.G.; Piersma, A.H.; Rietjens, I.

    2014-01-01

    Zebrafish embryos were exposed to concentration ranges of selected thyroid-active model compounds in order to assess the applicability of zebrafish-based developmental scoring systems within an alternative testing strategy to detect the developmental toxicity of thyroid-active compounds. Model

  3. Tests of biological activity of metabolites from Penicillium expansum (Link Thom various isolates

    Directory of Open Access Journals (Sweden)

    Halina Borecka

    2013-12-01

    Full Text Available Aqrobacterium tumefaciens and cucumber, mustard and linseeds were compared as test organisms for evaluation of the biological activity of patulin. It was found that the reaction of cucumber seeds and linseed to the patulin concentrations was more pronounced than that of mustard and Aqrobacterium tumefaciens. The activity of metabolites produced by Penicillium expansum was investigated with the use of cucumber seeds. As measure of activity served the percentage of radicule growth inhibition was compared with the growth in control seeds. The biological activity of the metabolites was specific for the isolates, those from apples being more active. Thirty two isolates from pears and 34 from apples were examined.

  4. Electromyography Activation Levels of the 3 Gluteus Medius Subdivisions During Manual Strength Testing

    DEFF Research Database (Denmark)

    Otten, Roald; Tol, Johannes L; Holmich, Per

    2015-01-01

    deficits and guide specific rehabilitation programs. However, the optimal positions for assessing the strength and activation of these subdivisions are unknown. OBJECTIVE: The first aim was to establish which strength-testing positions produce the highest surface electromyography (sEMG) activation levels...... of the individual GM subdivisions. The second aim was to evaluate differences in sEMG activation levels between the tested and contralateral (stabilizing) leg. METHOD: Twenty healthy physically active male subjects participated in this study. Muscle activity using sEMG was recorded for the GM subdivisions in 8......STUDY DESIGN: Cross-sectional. CONTEXT: Gluteus medius (GM) muscle dysfunction is associated with overuse injury. The GM is functionally composed of 3 separate subdivisions: anterior, middle, and posterior. Clinical assessment of the GM subdivisions is relevant to detect strength and activation...

  5. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury.

    Science.gov (United States)

    Husted, Rasmus S; Bencke, Jesper; Andersen, Lars L; Myklebust, Grethe; Kallemose, Thomas; Lauridsen, Hanne B; Hölmich, Per; Aagaard, Per; Zebis, Mette K

    2016-06-01

    Reduced ability to activate the medial hamstring muscles during a sports-specific sidecutting movement has been found to be a potential risk factor for non-contact ACL injury. However, whether a reduced ability to activate the medial hamstring muscle is a general neuromuscular phenomenon and thereby observable independently of the type of clinical screening tests used is not known. This cross sectional study investigated the rank correlation of knee joint neuromuscular activity between three different ACL injury risk screening tests. Sixty-two adolescent female elite football and handball players (16.7±1.3years) participated in the study. Using surface electromyography (EMG) assessment, the neuromuscular activity of medial hamstring muscle (semitendinosus, ST), lateral hamstring muscle (biceps femoris, BF) and quadriceps muscle (vastus lateralis, VL) were monitored during three standardized screening tests - i.e. one-legged horizontal hop (OLH), drop vertical jump (DJ) and sidecutting (SC). Neuromuscular pre-activity was measured in the time interval 10ms prior to initial contact on a force plate. For neuromuscular hamstring muscle pre-activity, correlation analysis (Spearman correlation coefficient) showed low-to-moderate correlations between SC and 1) DJ (rs=0.34-0.36, Phamstring pre-activity share some common variance during the examined tests. However, a lack of strong correlation suggests that we cannot generalize one risk factor during one test to another test. The present data demonstrate that one-legged horizontal hop and drop vertical jump testing that are commonly used in the clinical setting does not resemble the specific neuromuscular activity patterns known to exist during sidecutting, a well known high risk movement for non-contact ACL injury. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Anticipated Effectiveness of Active Noise Control in Propeller Aircraft Interiors as Determined by Sound Quality Tests

    Science.gov (United States)

    Powell, Clemans A.; Sullivan, Brenda M.

    2004-01-01

    Two experiments were conducted, using sound quality engineering practices, to determine the subjective effectiveness of hypothetical active noise control systems in a range of propeller aircraft. The two tests differed by the type of judgments made by the subjects: pair comparisons in the first test and numerical category scaling in the second. Although the results of the two tests were in general agreement that the hypothetical active control measures improved the interior noise environments, the pair comparison method appears to be more sensitive to subtle changes in the characteristics of the sounds which are related to passenger preference.

  7. Current status of the active test at RRP and development programs for the advanced melter

    International Nuclear Information System (INIS)

    Kanehira, Norio

    2016-01-01

    The vitrification facility in Rokkasho Reprocessing Plant started the active tests to solidify HAW into the glass in 2007 which was the examination of the final stage before the operation, but the active test had to be discontinued due to the trouble of glass melter operation with down of pouring by deposit of noble metals on the melter bottom. After the equipment and operating conditions were improved in response to the result of the mock-up tests, a series of active tests were restarted active tests in May, 2012. These tests were finished with enough confirmation of stability in the state such as glass temperature and controlling the noble metals. JNFL has been developed the advanced melter, Joule heated ceramic melter, and the design of the advanced melter is largely different from the existing one. For the confirmation of the advanced melter performances, the full-scale inactive tests had been performed and successfully finished. This paper describes outline of development for advanced melter in Rokkasho Reprocessing Plant. (author)

  8. Current Limitations and Recommendations to Improve Testing for the Environmental Assessment of Endocrine Active Substances

    DEFF Research Database (Denmark)

    Coady, Katherine K; Biever, Ronald C; Denslow, Nancy D

    2017-01-01

    In this paper existing regulatory frameworks and test systems for assessing potential endocrine-active chemicals are described, and associated challenges discussed, along with proposed approaches to address these challenges. Regulatory frameworks vary somewhat across geographies, but all basically...... evaluate whether a chemical possesses endocrine activity and whether this activity can result in adverse outcomes either to humans or the environment. Current test systems include in silico, in vitro and in vivo techniques focused on detecting potential endocrine activity, and in vivo tests that collect...... methods currently do not exist, and addressing key endocrine pathways of possible concern in addition to those associated with estrogen, androgen and thyroid signaling. This article is protected by copyright. All rights reserved....

  9. Summary of the first step of active test of separation facility at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Iseki, T.; Takahashi, N.; Tanaka, Y.

    2006-01-01

    Full text: Full text: 1. Purpose: The aim of this presentation is to explain and discuss the first step of active test results in the Separation facility. We had previously performed uranium tests with depleted uranium from February of 2005 to January of 2006. Then, the first step of active test has been in progress since March of 2006 toward the start of commercial operation. 2. Outline of Separation facility: PUREX process is selected for the separation facility that has 6 pulsed columns (PC) and 6 mixer-settlers banks (MS). The dissolution solution is fed to extraction PC where U and Pu are extracted to solvent. The loaded solvent is washed with nitric acid in FP scrubbing PC and T/Tc scrubbing PC and then the aqueous raffinates from T/Tc scrubbing PC flows to complementary extraction MS to recover slightly back extracted U and Pu. The loaded solvent flows to Pu stripping PC where U remains in solvent and Pu is stripped. And U in Pu stream is washed with solvent. A Pu decontamination of U loaded solvent is carried out in Pu barrier MS, and U is back extracted from solvent with acidified water at higher temperature in U stripping MS. The outlet aqueous phases are washed with n-dodecane to remove the TBP. 3. Main active test contents: The active test is performed with the spent fuel elements. The main purpose of active test is (1) Checking of the separation and stripping performances, (2) Checking of uranium and plutonium losses into wastes, (3) Checking of diluent washing efficiency and (4) Checking of the throughout performance. 4. Results: The test results of the first step of active test are presented: (a) Plutonium stripping performance, (b) decontamination factor of fission products and (c) uranium and plutonium losses into wastes

  10. Active vibration control testing of the SPICES program: final demonstration article

    Science.gov (United States)

    Dunne, James P.; Jacobs, Jack H.

    1996-05-01

    The Synthesis and Processing of Intelligent Cost Effective Structures (SPICES) Program is a partnership program sponsored by the Advanced Research Projects Agency. The mission of the program is to develop cost effective material processing and synthesis technologies to enable new products employing active vibration suppression and control devices to be brought to market. The two year program came to fruition in 1995 through the fabrication of the final smart components and testing of an active plate combined with two trapezoidal rails, forming an active mount. Testing of the SPICES combined active mount took place at McDonnell Douglas facilities in St. Louis, MO, in October-December 1995. Approximately 15 dB reduction in overall response of a motor mounted on the active structure was achieved. Further details and results of the SPICES combined active mount demonstration testing are outlined. Results of numerous damping and control strategies that were developed and employed in the testing are presented, as well as aspects of the design and fabrication of the SPICES active mount components.

  11. Current limitations and recommendations to improve testing for the environmental assessment of endocrine active substances

    Science.gov (United States)

    Coady, Katherine K.; Biever, Ronald C.; Denslow, Nancy D.; Gross, Melanie; Guiney, Patrick D.; Holbech, Henrik; Karouna-Renier, Natalie K.; Katsiadaki, Ioanna; Krueger, Hank; Levine, Steven L.; Maack, Gerd; Williams, Mike; Wolf, Jeffrey C.; Ankley, Gerald T.

    2017-01-01

    In the present study, existing regulatory frameworks and test systems for assessing potential endocrine active chemicals are described, and associated challenges are discussed, along with proposed approaches to address these challenges. Regulatory frameworks vary somewhat across geographies, but all basically evaluate whether a chemical possesses endocrine activity and whether this activity can result in adverse outcomes either to humans or to the environment. Current test systems include in silico, in vitro, and in vivo techniques focused on detecting potential endocrine activity, and in vivo tests that collect apical data to detect possible adverse effects. These test systems are currently designed to robustly assess endocrine activity and/or adverse effects in the estrogen, androgen, and thyroid hormone signaling pathways; however, there are some limitations of current test systems for evaluating endocrine hazard and risk. These limitations include a lack of certainty regarding: 1) adequately sensitive species and life stages; 2) mechanistic endpoints that are diagnostic for endocrine pathways of concern; and 3) the linkage between mechanistic responses and apical, adverse outcomes. Furthermore, some existing test methods are resource intensive with regard to time, cost, and use of animals. However, based on recent experiences, there are opportunities to improve approaches to and guidance for existing test methods and to reduce uncertainty. For example, in vitro high-throughput screening could be used to prioritize chemicals for testing and provide insights as to the most appropriate assays for characterizing hazard and risk. Other recommendations include adding endpoints for elucidating connections between mechanistic effects and adverse outcomes, identifying potentially sensitive taxa for which test methods currently do not exist, and addressing key endocrine pathways of possible concern in addition to those associated with estrogen, androgen, and thyroid

  12. Do collaborative practical tests encourage student-centered active learning of gross anatomy?

    Science.gov (United States)

    Green, Rodney A; Cates, Tanya; White, Lloyd; Farchione, Davide

    2016-05-06

    Benefits of collaborative testing have been identified in many disciplines. This study sought to determine whether collaborative practical tests encouraged active learning of anatomy. A gross anatomy course included a collaborative component in four practical tests. Two hundred and seven students initially completed the test as individuals and then worked as a team to complete the same test again immediately afterwards. The relationship between mean individual, team, and difference (between team and individual) test scores to overall performance on the final examination (representing overall learning in the course) was examined using regression analysis. The overall mark in the course increased by 9% with a decreased failure rate. There was a strong relationship between individual score and final examination mark (P learning occurring during the collaborative testing and that weaker students gained the benefit from team marks without significant active learning taking place. This negative outcome may be due to insufficient encouragement of the active learning strategies that were expected to occur during the collaborative testing process. An improved understanding of the efficacy of collaborative assessment could be achieved through the inclusion of questionnaire based data to allow a better interpretation of learning outcomes. Anat Sci Educ 9: 231-237. © 2015 American Association of Anatomists. © 2015 American Association of Anatomists.

  13. In vitro genotoxicity of neutral red after photo-activation and metabolic activation in the Ames test, the micronucleus test and the comet assay.

    Science.gov (United States)

    Guérard, Melanie; Zeller, Andreas; Singer, Thomas; Gocke, Elmar

    2012-07-04

    Neutral red (Nr) is relatively non-toxic and is widely used as indicator dye in many biological test systems. It absorbs visible light and is known to act as a photosensitizer, involving the generation of reactive oxygen species (type-I reaction) and singlet oxygen (type-II reaction). The mutagenicity of Nr was determined in the Ames test (with Salmonella typhimurium strains TA1535, TA97, TA98, TA98NR, TA100, and TA102) with and without metabolic activation, and with and without photo-activation on agar plates. Similarly to the situation following metabolic activation, photo-mutagenicity of Nr was seen with all Salmonella strains tested, albeit with different effects between these strains. To our knowledge, Nr is the only photo-mutagen showing such a broad action. Since the effects are also observed in strains not known to be responsive to ROS, this indicates that ROS production is not the sole mode of action that leads to photo-genotoxicity. The reactive species produced by irradiation are short-lived as pre-irradiation of an Nr solution did not produce mutagenic effects when added to the bacteria. In addition, mutagenicity in TA98 following irradiation was stronger than in the nitroreductase-deficient strain TA98NR, indicating that nitro derivatives that are transformed by bacterial nitroreductase to hydroxylamines appear to play a role in the photo-mutagenicity of Nr. Photo-genotoxicity of Nr was further investigated in the comet assay and micronucleus test in L5178Y cells. Concentration-dependent increases in primary DNA damage and in the frequency of micronuclei were observed after irradiation. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. The accomplishments of lithium target and test facility validation activities in the IFMIF/EVEDA phase

    Science.gov (United States)

    Arbeiter, Frederik; Baluc, Nadine; Favuzza, Paolo; Gröschel, Friedrich; Heidinger, Roland; Ibarra, Angel; Knaster, Juan; Kanemura, Takuji; Kondo, Hiroo; Massaut, Vincent; Saverio Nitti, Francesco; Miccichè, Gioacchino; O'hira, Shigeru; Rapisarda, David; Sugimoto, Masayoshi; Wakai, Eiichi; Yokomine, Takehiko

    2018-01-01

    As part of the engineering validation and engineering design activities (EVEDA) phase for the international fusion materials irradiation facility IFMIF, major elements of a lithium target facility and the test facility were designed, prototyped and validated. For the lithium target facility, the EVEDA lithium test loop was built at JAEA and used to test the stability (waves and long term) of the lithium flow in the target, work out the startup procedures, and test lithium purification and analysis. It was confirmed by experiments in the Lifus 6 plant at ENEA that lithium corrosion on ferritic martensitic steels is acceptably low. Furthermore, complex remote handling procedures for the remote maintenance of the target in the test cell environment were successfully practiced. For the test facility, two variants of a high flux test module were prototyped and tested in helium loops, demonstrating their good capabilities of maintaining the material specimens at the desired temperature with a low temperature spread. Irradiation tests were performed for heated specimen capsules and irradiation instrumentation in the BR2 reactor at SCK-CEN. The small specimen test technique, essential for obtaining material test results with limited irradiation volume, was advanced by evaluating specimen shape and test technique influences.

  15. ITER like lower hybrid passive active multi-junction antenna manufacturing and tests

    International Nuclear Information System (INIS)

    Guilhem, D.; Samaille, F.; Bertrand, B.; Lipa, M.; Achard, J.; Agarici, G.; Argouarch, A.; Armitano, A.; Bej, Z.; Berger-By, G.; Bouquey, F.; Brun, C.; Chantant, M.; Corbel, E.; Delmas, E.; Delpech, L.; Doceul, L.; Ekedahl, A.; Faisse, F.; Fejoz, P.; Goletto, C.; Goniche, M.; Hatchressian, J. C.; Hillairet, J.; Hoang, T.; Houry, M.; Joubert, P.; Lambert, R.; Lombard, G.; Madeleine, S.; Magne, R.; Marfisi, L.; Martinez, A.; Missirlian, M.; Mollard, P.; Poli, S.; Portafaix, C.; Preynas, M.; Prou, M.; Raulin, D.; Saille, A.; Soler, B.; Thouvenin, D.; Verger, J. M.; Volpe, D.; Vulliez, K.; Zago, B.

    2011-01-01

    A new concept of multijunction-type antenna has been developed, the Passive Active Multijunction, which improves the cooling of the waveguides and the damping of the neutron energy (for ITER) compared to Full Active Multijunction. Due to the complexity of the structures, prototypes of the mode converters and of the Passive-Active-Multijunction launcher were fabricated and tested, in order to validate the different manufacturing processes and the manufacturer's capability to face this challenging project. This paper describes the manufacturing process, the tests of the various prototypes and the construction of the final Passive-Active-Multijunction launcher, which entered into operation in October 2009. It has been commissioned and is fully operational on the Tore-Supra tokamak, since design objectives were reached in March 2010: 2.75 MW - 78 s, power density of 25 MW/m 2 in active waveguides, steady-state apparent surface temperatures ≤ 350 degrees C; 10 cm long distance coupling. (authors)

  16. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    Science.gov (United States)

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  17. Performance testing of real-time AI systems using the activation framework

    International Nuclear Information System (INIS)

    Becker, L.; Duckworth, J.; Laznovsky, A.; Green, P.

    1992-01-01

    This paper describes methods for automated performance testing of real-time artificial intelligence systems using the Activation Framework software development tool. The Activation Framework is suitable for applications such as the diagnosis of power system failures, which require the interpretation of large volumes of data in real-time. The Activation Framework consists of tools for compiling groups of Expert Systems rules into executable code modules, for automatically generating code modules from high level system configuration descriptions, and for automatically generating command files for program compilation and linking. It includes an operating system environment which provides the code which is common from one real-time AI applications to the next. It also includes mechanisms, described here, for automatic performance testing. The principal emphasis of this paper is on a rule based language which is used to capture performance specifications. This specification is compiled into code modules which are used to automatically test the system. This testing can validate that the system meets performance requirements during development and after maintenance. A large number of tests can be randomly generated and executed and the correctness of the outputs automatically validated. The paper also describes graph directed testing methods to minimize the number of test runs required

  18. Summary and recommendations of the NRC/INEL Activated Carbon Testing Program

    International Nuclear Information System (INIS)

    Scarpellino, C.D.; Sill, C.W.

    1986-01-01

    The Committee on Nuclear Air and Gas Treatment (CONAGT) of the American Society of Mechanical Engineers (ASME) sponsored an interlaboratory testing program, round-robin, of nuclear-grade activated carbon. The results of this round-robin revealed gross differences in penetration of radio-labeled methyl iodide as measured by the various laboratories when using Method A of the ASTM D-3803-79 Standard. These differences prompted the Nuclear Regulatory Commission (NRC) to establish the NRC/INEL Activated Carbon Testing Program to determine the causes of these discrepancies and to provide recommendations that could lead to an accurate and reliable testing procedure that would ensure an adequate method for assessing the capability of activated carbon to remove radioiodine from gas streams within commercial nuclear power plants. The NRC/INEL Activated Carbon Testing Program has conducted formal and informal interlaboratory comparisons to identify problems with the test method and its application and to assess the effectiveness of changes to procedures and equipment voluntarily implemented by commercial laboratories to mitigate the disparity of test results. The results of the first formal NRC/INEL Interlaboratory Comparison (IC) essentially verified the CONAGT round-robin results despite the use of a detailed test protocol. This data indicated that many of the participating laboratories probably had been operating outside the ASTM specifications for relative humidity (RH) and flow. In addition, this process provided information which was used to modify the testing protocol employed for the second NRC/INEL Interlaboratory Comparison (IC-2) to make it more rugged and reliable. These changes to the protocol together with the results of INEL sensitivity testing are the basis for the recommendations presented

  19. Is there a risk of active sensitization to PPD by patch testing the general population?

    Science.gov (United States)

    Thyssen, Jacob Pontoppidan; Menné, Torkil; Nielsen, Niels Henrik; Linneberg, Allan

    2007-08-01

    Para-phenylenediamine (PPD), a constituent of permanent hair dyes, may cause contact allergy in exposed individuals. It has previously been questioned whether a patch testing with PPD in population-based epidemiological studies is entirely safe. The Glostrup allergy studies patch tested the same cohort twice. In 1990, 567 persons were patch-tested and only one person had a (+) positive reaction to PPD. In 1998, 540 persons were re-invited to a new patch test and 365 (participation rate 68%) were re-tested. There were no positive reactions to PPD. These studies indicate that patch testing with PPD in individuals with no previous positive reactions to PPD or with only one previous positive reaction does not cause active sensitization and can be performed with minimal risk.

  20. Development and psychometric testing of the active aging scale for Thai adults.

    Science.gov (United States)

    Thanakwang, Kattika; Isaramalai, Sang-Arun; Hatthakit, Urai

    2014-01-01

    Active aging is central to enhancing the quality of life for older adults, but its conceptualization is not often made explicit for Asian elderly people. Little is known about active aging in older Thai adults, and there has been no development of scales to measure the expression of active aging attributes. The aim of this study was to develop a culturally relevant composite scale of active aging for Thai adults (AAS-Thai) and to evaluate its reliability and validity. EIGHT STEPS OF SCALE DEVELOPMENT WERE FOLLOWED: 1) using focus groups and in-depth interviews, 2) gathering input from existing studies, 3) developing preliminary quantitative measures, 4) reviewing for content validity by an expert panel, 5) conducting cognitive interviews, 6) pilot testing, 7) performing a nationwide survey, and 8) testing psychometric properties. In a nationwide survey, 500 subjects were randomly recruited using a stratified sampling technique. Statistical analyses included exploratory factor analysis, item analysis, and measures of internal consistency, concurrent validity, and test-retest reliability. Principal component factor analysis with varimax rotation resulted in a final 36-item scale consisting of seven factors of active aging: 1) being self-reliant, 2) being actively engaged with society, 3) developing spiritual wisdom, 4) building up financial security, 5) maintaining a healthy lifestyle, 6) engaging in active learning, and 7) strengthening family ties to ensure care in later life. These factors explained 69% of the total variance. Cronbach's alpha coefficient for the overall AAS-Thai was 0.95 and varied between 0.81 and 0.91 for the seven subscales. Concurrent validity and test-retest reliability were confirmed. The AAS-Thai demonstrated acceptable overall validity and reliability for measuring the multidimensional attributes of active aging in a Thai context. This newly developed instrument is ready for use as a screening tool to assess active aging levels among older

  1. eTEST: Developing a Smart Home HIV Testing Kit that Enables Active, Real-Time Follow-Up and Referral After Testing.

    Science.gov (United States)

    Wray, Tyler; Chan, Philip A; Simpanen, Erik; Operario, Don

    2017-05-08

    Men who have sex with men (MSM) are the group at highest risk for contracting human immunodeficiency virus (HIV) in the United States, but many do not test as frequently as recommended. Home-based self-testing (HBST) for HIV holds promise for promoting regular testing among these individuals, but currently available HBSTs have limited follow-up options, providing only a 1-800 number that participants can call. Failure to actively conduct follow-up counseling and referrals after HBST use could result in delays in seeking confirmatory testing and care among users receiving reactive (preliminary positive) test results. HBST also fails to connect users who test negative with other prevention services that can reduce their future risk for HIV. The aim of our study was to use qualitative research methods with high-risk MSM to inform development of a "smart" HBST kit. The kit utilizes existing Internet-of-Things (IoT) technologies to monitor HBST use in real-time and enable delivery of timely, active follow-up counseling and referrals over the phone. In phase 1, individual interviews (n=10) explored how participants might use HBST and their views and preferences for conducting counseling and referral after HBST. Based on these perspectives, we developed a smartphone app (iOS, Android) that uses data from light sensors on Bluetooth low energy (BLE) beacons to monitor when HBST kits are opened, facilitating timely follow-up phone contact with users. In phase 2, a usability study conducted among high-risk MSM (n=10) examined the acceptability and feasibility of this system and provided user perspectives after using the system along with HBST. Phase 1 themes suggested that MSM preferred HBST, that most thought active follow-up after HBST would be valuable, and that doing so over the phone within 24 h after testing was preferable. Phase 2 results showed that the eTEST system successfully detected HBST use in nearly all cases. Participant perspectives also suggested that the

  2. Activation analysis and waste management of China ITER helium cooled solid breeder test blanket module

    Energy Technology Data Exchange (ETDEWEB)

    Han, J.R., E-mail: hanjingru@163.co [North China Electric Power University, School of Nuclear Science and Engineering, Zhu-Xin-Zhuang, De-Wai, Beijing 102206 (China); Chen, Y.X.; Han, R. [North China Electric Power University, School of Nuclear Science and Engineering, Zhu-Xin-Zhuang, De-Wai, Beijing 102206 (China); Feng, K.M. [Southwestern Institute of Physics, P.O.Box 432, Chengdu 610041 (China); Forrest, R.A. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom)

    2010-08-15

    Activation characteristics have been assessed for the ITER China helium cooled solid breeder (CH-HCSB) 3 x 6 test blanket module (TBM). Taking a representative irradiation scenario, the activation calculations were performed by FISPACT code. Neutron fluxes distributions in the TBM were provided by a preceding MCNP calculation. These fluxes were passed to FISPACT for the activation calculation. The main activation parameters of the HCSB-TBM were calculated and discussed, such as activity, afterheat and contact dose rate. Meanwhile, the dominant radioactivity nuclides and reaction channel pathways have been identified. According to the Safety and Environmental Assessment of Fusion Power (SEAFP) waste management strategy, the activated materials can be re-used following the remote handling recycling options. The results will provide useful indications for further optimization design and waste management of the TBM.

  3. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury

    DEFF Research Database (Denmark)

    Husted, Rasmus S; Bencke, Jesper; Andersen, Lars Louis

    2016-01-01

    phenomenon and thereby observable independently of the type of clinical screening tests used is not known. This cross sectional study investigated the rank correlation of knee joint neuromuscular activity between three different ACL injury risk screening tests. METHODS: Sixty-two adolescent female elite......BACKGROUND: Reduced ability to activate the medial hamstring muscles during a sports-specific sidecutting movement has been found to be a potential risk factor for non-contact ACL injury. However, whether a reduced ability to activate the medial hamstring muscle is a general neuromuscular...... football and handball players (16.7±1.3years) participated in the study. Using surface electromyography (EMG) assessment, the neuromuscular activity of medial hamstring muscle (semitendinosus, ST), lateral hamstring muscle (biceps femoris, BF) and quadriceps muscle (vastus lateralis, VL) were monitored...

  4. The antioxidant activity test by using DPPH method from the white tea using different solvents

    Science.gov (United States)

    Darmajana, Doddy A.; Hadiansyah, Firman; Desnilasari, Dewi

    2017-11-01

    The solvents used in this study are: aquades, ethanol and glacial acetic acid. The raw material as the source of antioxidants is white tea. Pure Quercetin is used as a comparing antioxidant. The treatment design was the solvent type for extraction, while the antioxidant activity was tested using DPPH method, with IC50 as the reference of antioxidant activity value. The results of antioxidant activity tests with three different solvent types are IC50 of 22,499 µg/mL for aquades, IC50 of 13,317 µg/mL for Ethanol and IC50 of 60,555 µg/mL for Glacial Acetic Acid. As a control of the standard antioxidant activity value of Quercetin is 4,313 µg/mL.

  5. Detailed leak detection test plan and schedule for the Oak Ridge National Laboratory LLLW active tanks

    International Nuclear Information System (INIS)

    Douglas, D.G.; Maresca, J.W. Jr.

    1993-03-01

    This document provides a detailed leak detection test plan and schedule for leak testing many of the tanks that comprise the active portion of the liquid low-level waste (LLLW) system at the Oak Ridge National Laboratory (ORNL). This plan was prepared in response to the requirements of the Federal Facility Agreement (FFA) between the US Department of Energy (DOE) and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC)

  6. Design of The Test Stand for Hydraulic Active Heave Compensation System

    Directory of Open Access Journals (Sweden)

    Jakubowski Arkadiusz

    2017-01-01

    Full Text Available The article presented here described the design of a test stand for hydraulic active heave compensation system. The simulation of sea waves is realized by the use of hydraulic cylinder. A hydraulic motor is used for sea waves compensation. The hydraulic cylinder and the hydraulic motor are controlled by electrohydraulic servo valves. For the measurements Authors used displacement sensor and incremental encoder. Control algorithm is implemented on the PLC. The performed tests included hydraulic actuator and hydraulic motor step responses.

  7. Field tests and evaluations of the IAEA Active-Well Coincidence Counter

    International Nuclear Information System (INIS)

    Krick, M.S.; Rinard, P.M.

    1982-12-01

    This report summarizes and evaluates field tests of the Active Well Coincidence Counter (AWCC) at Winfrith and Dounreay, United Kingdom. The applicability of the AWCC for assaying the uranium content of a wide variety of materials was demonstrated and calibration curves were generated. The AWCC was used in three modes (fast, thermal, and passive) while assaying powders, pellets, cartridges, plates, assorted residues, and materials-testing-reactor fuel assemblies

  8. Can disc diffusion susceptibility tests assess the antimicrobial activity of engineered nanoparticles?

    Science.gov (United States)

    Kourmouli, Angeliki; Valenti, Marco; van Rijn, Erwin; Beaumont, Hubertus J. E.; Kalantzi, Olga-Ioanna; Schmidt-Ott, Andreas; Biskos, George

    2018-03-01

    The use of disc diffusion susceptibility tests to determine the antibacterial activity of engineered nanoparticles (ENPs) is questionable because their low diffusivity practically prevents them from penetrating through the culture media. In this study, we investigate the ability of such a test, namely the Kirby-Bauer disc diffusion test, to determine the antimicrobial activity of Au and Ag ENPs having diameters from 10 to 40 nm on Escherichia coli cultures. As anticipated, the tests did not show any antibacterial effects of Au nanoparticles (NPs) as a result of their negligible diffusivity through the culture media. Ag NPs on the other hand exhibited a strong antimicrobial activity that was independent of their size. Considering that Ag, in contrast to Au, dissolves upon oxidation and dilution in aqueous solutions, the apparent antibacterial behavior of Ag NPs is attributed to the ions they release. The Kirby-Bauer method, and other similar tests, can therefore be employed to probe the antimicrobial activity of ENPs related to their ability to release ions rather than to their unique size-dependent properties. [Figure not available: see fulltext.

  9. Determinants of physical activity among people with spinal cord injury: a test of social cognitive theory.

    Science.gov (United States)

    Ginis, Kathleen A Martin; Latimer, Amy E; Arbour-Nicitopoulos, Kelly P; Bassett, Rebecca L; Wolfe, Dalton L; Hanna, Steven E

    2011-08-01

    Little theory-based research has focused on understanding and increasing physical activity among people with physical disabilities. Testing a social cognitive theory-based model of determinants is important for identifying variables to target in physical activity-enhancing interventions. The aim of this study is to examine Social Cognitive Theory variables as predictors of physical activity among people living with spinal cord injury. Structural equation modeling was used to test a model of Social Cognitive Theory predictors of physical activity (n=160). The model explained 39% of the variance in physical activity. Self-regulation was the only significant, direct predictor. Self-regulatory efficacy and outcome expectations had indirect effects, mediated by self-regulation. Social Cognitive Theory is useful for predicting physical activity in people with spinal cord injury. Self-regulation is the most potent Social Cognitive Theory predictor of physical activity in people with spinal cord injury. Self-regulation and its determinants should be targeted in physical activity-enhancing interventions.

  10. Testing the applicability of rapid on-site enzymatic activity detection for surface water monitoring

    Science.gov (United States)

    Stadler, Philipp; Vogl, Wolfgang; Juri, Koschelnik; Markus, Epp; Maximilian, Lackner; Markus, Oismüller; Monika, Kumpan; Peter, Strauss; Regina, Sommer; Gabriela, Ryzinska-Paier; Farnleitner Andreas, H.; Matthias, Zessner

    2015-04-01

    On-site detection of enzymatic activities has been suggested as a rapid surrogate for microbiological pollution monitoring of water resources (e.g. using glucuronidases, galactosidases, esterases). Due to the possible short measuring intervals enzymatic methods have high potential as near-real time water quality monitoring tools. This presentation describes results from a long termed field test. For twelve months, two ColiMinder devices (Vienna Water Monitoring, Austria) for on-site determination of enzymatic activity were tested for stream water monitoring at the experimental catchment HOAL (Hydrological Open Air Laboratory, Center for Water Resource Systems, Vienna University of Technology). The devices were overall able to follow and reflect the diverse hydrological and microbiological conditions of the monitored stream during the test period. Continuous data in high temporal resolution captured the course of enzymatic activity in stream water during diverse rainfall events. The method also proofed sensitive enough to determine diurnal fluctuations of enzymatic activity in stream water during dry periods. The method was able to capture a seasonal trend of enzymatic activity in stream water that matches the results gained from Colilert18 analysis for E. coli and coliform bacteria of monthly grab samples. Furthermore the comparison of ColiMinder data with measurements gained at the same test site with devices using the same method but having different construction design (BACTcontrol, microLAN) showed consistent measuring results. Comparative analysis showed significant differences between measured enzymatic activity (modified fishman units and pmol/min/100ml) and cultivation based analyses (most probable number, colony forming unit). Methods of enzymatic activity measures are capable to detect ideally the enzymatic activity caused by all active target bacteria members, including VBNC (viable but nonculturable) while cultivation based methods cannot detect VBNC

  11. Smoking, activity level and exercise test outcomes in a young population sample without cardiopulmonary disease.

    Science.gov (United States)

    Vozoris, N T; O'donnell, D E

    2015-01-01

    Whether reduced activity level and exercise intolerance precede the clinical diagnosis of cardiopulmonary disorders in smokers is not known. We examined activity level and exercise test outcomes in a young population-based sample without overt cardiopulmonary disease, differentiating by smoking history. This was a multiyear cross-sectional study using United States National Health and Nutrition Examination Survey data from 1999-2004. Self-reported activity level and incremental exercise treadmill testing were obtained on survey participants ages 20-49 years, excluding individuals with cardio-pulmonary disease. Three thousand seven hundred and one individuals completed exercise testing. Compared to never smokers, current smokers with >10 pack years reported significantly higher odds of little or no recreation, sport, or physical activity (adjusted OR 1.62; 95% CI 1.12-2.35). Mean perceived exertion ratings (Borg 6-20) at an estimated standardized workload were significantly greater among current smokers (18.3-18.6) compared to never (17.3) and former smokers (17.9) (psmoking abstinence was associated with significantly lower likelihood of low estimated peak oxygen uptake categorization (psmoking cessation, these results set the stage for future studies that examine mechanisms of activity restriction in young smokers and the utility of measures of activity restriction in the earlier diagnosis of smoking-related diseases.

  12. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  13. Review of Department of Energy HEPA filter test activities, FY 1990--FY 1992

    International Nuclear Information System (INIS)

    McIntyre, J.A.

    1992-01-01

    Filter Test Facilities (FTFs) and the FTF Technical Support Group (TSG) continue to provide services to the Department of Energy (DOE). Additional tasks relating to the HEPA filter cycle have been added to the TSG. The tasks include the quality assessment review for the in-place testing of HEPA filters at DOE sites and the formation of an in-place testing standards writing group. Summary of ongoing FTFs and TSG activities for FY 1990-FY 1992 including the technical input for implementation of the High Flow Alternative Test System (HFATS), update of the DOE Standards, the status of the quality assessment review and in-place testing standards writing group are discussed

  14. Analysis of five streptokinase formulations using the euglobulin lysis test and the plasminogen activation assay

    Directory of Open Access Journals (Sweden)

    Couto L.T.

    2004-01-01

    Full Text Available Streptokinase, a 47-kDa protein isolated and secreted by most group A, C and G ß-hemolytic streptococci, interacts with and activates human protein plasminogen to form an active complex capable of converting other plasminogen molecules to plasmin. Our objective was to compare five streptokinase formulations commercially available in Brazil in terms of their activity in the in vitro tests of euglobulin clot formation and of the hydrolysis of the plasmin-specific substrate S-2251(TM. Euglobulin lysis time was determined using a 96-well microtiter plate. Initially, human thrombin (10 IU/ml and streptokinase were placed in individual wells, clot formation was initiated by the addition of plasma euglobulin, and turbidity was measured at 340 nm every 30 s. In the second assay, plasminogen activation was measured using the plasmin-specific substrate S-2251(TM. Streptase(TM was used as the reference formulation because it presented the strongest fibrinolytic activity in the euglobulin lysis test. The Unitinase(TM and Solustrep(TM formulations were the weakest, showing about 50% activity compared to the reference formulation. All streptokinases tested activated plasminogen but significant differences were observed. In terms of total S-2251(TM activity per vial, Streptase(TM (75.7 ± 5.0 units and Streptonase(TM (94.7 ± 4.6 units had the highest activity, while Unitinase(TM (31.0 ± 2.4 units and Strek(TM (32.9 ± 3.3 units had the weakest activity. Solustrep(TM (53.3 ± 2.7 units presented intermediate activity. The variations among the different formulations for both euglobulin lysis test and chromogenic substrate hydrolysis correlated with the SDS-PAGE densitometric results for the amount of 47-kDa protein. These data show that the commercially available clinical streptokinase formulations vary significantly in their in vitro activity. Whether these differences have clinical implications needs to be investigated.

  15. A Rapid Blood Test To Determine the Active Status and Duration of Acute Viral Infection.

    Science.gov (United States)

    Zheng, Tianyu; Finn, Caroline; Parrett, Christopher J; Dhume, Kunal; Hwang, Ji Hae; Sidhom, David; Strutt, Tara M; Li Sip, Yuen Yee; McKinstry, Karl K; Huo, Qun

    2017-11-10

    The ability to rapidly detect and diagnose acute viral infections is crucial for infectious disease control and management. Serology testing for the presence of virus-elicited antibodies in blood is one of the methods used commonly for clinical diagnosis of viral infections. However, standard serology-based tests have a significant limitation: they cannot easily distinguish active from past, historical infections. As a result, it is difficult to determine whether a patient is currently infected with a virus or not, and on an optimal course of action, based off of positive serology testing responses. Here, we report a nanoparticle-enabled blood test that can help overcome this major challenge. The new test is based on the analysis of virus-elicited immunoglobulin G (IgG) antibody present in the protein corona of a gold nanoparticle surface upon mixing the gold nanoparticles with blood sera. Studies conducted on mouse models of influenza A virus infection show that the test gives positive responses only in the presence of a recent acute viral infection, approximately between day 14 and day 21 following the infection, and becomes negative thereafter. When used together with the traditional serology testing, the nanoparticle test can determine clearly whether a positive serology response is due to a recent or historical viral infection. This new blood test can provide critical clinical information needed to optimize further treatment and/or to determine if further quarantining should be continued.

  16. Overview of the testing activities on ITER sub-scale pre-compression rings

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo, E-mail: paolo.rossi@enea.it [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, C.P. 65, 00044 Frascati, Rome (Italy); Capobianchi, Mario; Crescenzi, Fabio; Massimi, Alberto; Mugnaini, Giampiero; Pizzuto, Aldo [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, C.P. 65, 00044 Frascati, Rome (Italy); Knaster, Juan [ITER Organisation, Route de Vinon sur Verdon, 13115, St. Paul lez Durance (France); Rajainmaki, Hannu [FUSION FOR ENERGY, Josep Pla no. 2, Torres Diagonal Litoral Edificio B3, 08019 Barcelona (Spain)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer ENEA developed a high strength glass fiber-epoxy composite for ITER pre-compression rings. Black-Right-Pointing-Pointer High UTS values were obtained at RT on linear specimens (2200 MPa) and on scaled ring mock-ups (1550 MPa). Black-Right-Pointing-Pointer Creep tests showed very low creep strain and creep rates. Black-Right-Pointing-Pointer Long term tests showed no significant stress relaxation on the ring mock-ups. - Abstract: After a first R and D and testing activity to develop and characterize by tensile and creep tests a high strength glass fiber-epoxy composite as reference material for the manufacture of ITER pre-compression rings, ENEA designed and manufactured a dedicated testing facility and different sub-scale composite ring mock-ups in order to characterize their mechanical properties. The paper reports the results of the overall testing activities performed during the last years on a total number of eleven sub-scale pre-compression ring mock-ups manufactured by winding S2 glass fibers on a diameter of 1 m (1/5 of the full scale) both by vacuum pressure epoxy impregnation (VPI) and filament wet winding techniques (WW). The first three rings were manufactured by ENEA Frascati thanks to a particular VPI technique; one of them was used as base composite material to manufacture different sets of specimens for shear, compression and non destructive tests (NDT). Then, five other mock-ups were manufactured following ENEA VPI process and three using WW technique by two different industrial companies. The rings were tested in ENEA Frascati in a dedicated hydraulic testing machine consisting of 18 radial actuators working in position control with a total load capability of 1000 tons. The complete testing campaign consisted of six ultimate tensile strength (UTS) tests and four stress relaxation (SR) tests. The tests demonstrated that the composite (S2 glass-epoxy) is a valid and viable solution for the ITER pre

  17. Can vaccinia virus be replaced by MVA virus for testing virucidal activity of chemical disinfectants?

    Directory of Open Access Journals (Sweden)

    Rapp Ingrid

    2010-06-01

    Full Text Available Abstract Background Vaccinia virus strain Lister Elstree (VACV is a test virus in the DVV/RKI guidelines as representative of the stable enveloped viruses. Since the potential risk of laboratory-acquired infections with VACV persists and since the adverse effects of vaccination with VACV are described, the replacement of VACV by the modified vaccinia Ankara strain (MVA was studied by testing the activity of different chemical biocides in three German laboratories. Methods The inactivating properties of different chemical biocides (peracetic acid, aldehydes and alcohols were tested in a quantitative suspension test according to the DVV/RKI guideline. All tests were performed with a protein load of 10% fetal calf serum with both viruses in parallel using different concentrations and contact times. Residual virus was determined by endpoint dilution method. Results The chemical biocides exhibited similar virucidal activity against VACV and MVA. In three cases intra-laboratory differences were determined between VACV and MVA - 40% (v/v ethanol and 30% (v/v isopropanol are more active against MVA, whereas MVA seems more stable than VACV when testing with 0.05% glutardialdehyde. Test accuracy across the three participating laboratories was high. Remarkably inter-laboratory differences in the reduction factor were only observed in two cases. Conclusions Our data provide valuable information for the replacement of VACV by MVA for testing chemical biocides and disinfectants. Because MVA does not replicate in humans this would eliminate the potential risk of inadvertent inoculation with vaccinia virus and disease in non-vaccinated laboratory workers.

  18. Speeding up pyrogenicity testing: Identification of suitable cell components and readout parameters for an accelerated monocyte activation test (MAT).

    Science.gov (United States)

    Stoppelkamp, Sandra; Würschum, Noriana; Stang, Katharina; Löder, Jasmin; Avci-Adali, Meltem; Toliashvili, Leila; Schlensak, Christian; Wendel, Hans Peter; Fennrich, Stefan

    2017-02-01

    Pyrogen testing represents a crucial safety measure for parental drugs and medical devices, especially in direct contact with blood or liquor. The European Pharmacopoeia regulates these quality control measures for parenterals. Since 2010, the monocyte activation test (MAT) has been an accepted pyrogen test that can be performed with different human monocytic cell sources: whole blood, isolated monocytic cells or monocytic cell lines with IL1β, IL6, or TNFα as readout cytokines. In the present study, we examined the three different cell sources and cytokine readout parameters with the scope of accelerating the assay time. We could show that despite all cell types being able to detect pyrogens, primary cells were more sensitive than the monocytic cell line. Quantitative real-time PCR revealed IL6 mRNA transcripts having the largest change in Ct-values upon LPS-stimulation compared to IL1β and TNFα, but quantification was unreliable. IL6 protein secretion from whole blood or peripheral blood mononuclear cells (PBMC) was also best suited for an accelerated assay with a larger linear range and higher signal-to-noise ratios upon LPS-stimulation. The unique combination with propan-2-ol or a temperature increase could additionally increase the cytokine production for earlier detection in PBMC. The increased incubation temperature could finally increase not only responses to lipopolysaccharides (LPS) but also other pyrogens by up to 13-fold. Therefore, pyrogen detection can be accelerated considerably by using isolated primary blood cells with an increased incubation temperature and IL6 as readout. These results could expedite assay time and thus help to promote further acceptance of the MAT. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. 78 FR 60287 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2013-10-01

    ... communication strategies, messages, and labels. These communications will aim to improve public understanding of... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-1164] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  20. 75 FR 51271 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2010-08-19

    ... communication strategies, messages, and labels. These communications will aim to improve public understanding of... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0420] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  1. 75 FR 39952 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2010-07-13

    ... communications will aim to improve public understanding of the risks and benefits of using medical devices and... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0344] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  2. Partnering with School Nutrition Professionals to Promote Fruit and Vegetable Intake through Taste-Testing Activities

    Science.gov (United States)

    Cirignano, Sherri M.; Hughes, Luanne J.; Wu-Jung, Corey J.; Morgan, Kathleen; Grenci, Alexandra; Savoca, LeeAnne

    2013-01-01

    The Healthy, Hunger-Free Kids Act (HHFKA) of 2010 sets new nutrition standards for schools, requiring them to serve a greater variety and quantity of fruits and vegetables. Extension educators in New Jersey partnered with school nutrition professionals to implement a school wellness initiative that included taste-testing activities to support…

  3. 78 FR 30899 - Agency Information Collection Activities; Comment Request; NCES Cognitive, Pilot, and Field Test...

    Science.gov (United States)

    2013-05-23

    ... requested data in the desired format. ED is soliciting comments on the proposed information collection... and methodologies. The procedures utilized to this effect include but are not limited to experiments... activities, pilot testing, exploratory interviews, experiments with questionnaire design, and usability...

  4. Child-Robot Interaction in the Wild : Field Testing Activities of the ALIZ-E Project

    NARCIS (Netherlands)

    Greeff, J. de; Blanson Henkemans, O.A.; Fraaije, A.; Solms, L.; Wigdor, N.; Bierman, B.

    2014-01-01

    A field study was conducted in which CRI activities developed by the ALIZ-E project were tested with the project's primary user group: children with diabetes. This field study resulted in new insights in the modalities and roles a robot aimed at CRI in a healthcare setting might utilise, while in

  5. Screening of Plant Extracts for Antioxidant Activity: a Comparative Study on Three Testing Methods

    NARCIS (Netherlands)

    Koleva, I.; Beek, van T.A.; Linssen, J.P.H.; Groot, de Æ.; Evstatieva, L.N.

    2002-01-01

    Three methods widely employed in the evaluation of antioxidant activity, namely 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging method, static headspace gas chromatography (HS-GC) and -carotene bleaching test (BCBT), have been compared with regard to their application in the screening of

  6. Mutagenic and antimutagenic activities of bioflavonoids and structural analogues in the Ames/Salmonella test

    NARCIS (Netherlands)

    Mohn GR; Van der Stel JJ; Stavenuiter JFC; Hamzink MRJ; Kreijl CF; LEO; LBO

    1996-01-01

    The mutagenic and antimutagenic properties of bioflavonoids were determined in the bacterial mutagenicity test of Ames, using Salmonella typhimurium strains TA98 and TA100. The decreasing order of mutagenic activity found in both strains was quercetin>myricetin-kaempferol>morin hydrate. The

  7. 21 CFR 864.7140 - Activated whole blood clotting time tests.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Activated whole blood clotting time tests. 864.7140 Section 864.7140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864...

  8. Assessment of brain activation regulation in first graders via RAN / RAS test

    Directory of Open Access Journals (Sweden)

    Tatiana V. Akhutina

    2015-03-01

    Full Text Available RAN / RAS test (Rapid Automatized Naming / Rapid Alternating Stimulus has been used successfully used by many psychologists, primarily to predict the risk of dyslexia, as it includes a language component and requires good visual-verbal connections. However, The research demonstrates that the low speed of naming is an effective indicator of neurocognitive problems of information processing as a whole (learning difficulties in general, not just reading difficulties. This can be explained in two ways: disturbance of executive mental control and the difficulties of automatization: the difficulties of the transition from a controlled energy-consuming assignment to a less energy-consuming one. The second interpretation describes the problems of energy resources of cognitive functioning. It is similar to weak maintenance of cortical structures activation. However, using the test mentioned herewith for assessing functions of activation regulation has not been described previously. In terms of the Luria’s three functional units of the brain theory the RAN / RAS test can be considered as sensitive to the weakness of the first unit, whose function is to maintain the activity of cortical structures. So the aim of the research is to prove the possibility of assessing the activation regulation using the RAN / RAS test. This issue is relevant because neuropsychological tools for determining the weakness of Unit I functions are not quite sufficient, while the problem of “energetic” unit ranks first in the frequency of occurrence in children with learning disabilities.

  9. Relationships between spatial activities and scores on the mental rotation test as a function of sex.

    Science.gov (United States)

    Ginn, Sheryl R; Pickens, Stefanie J

    2005-06-01

    Previous results suggested that female college students' scores on the Mental Rotations Test might be related to their prior experience with spatial tasks. For example, women who played video games scored better on the test than their non-game-playing peers, whereas playing video games was not related to men's scores. The present study examined whether participation in different types of spatial activities would be related to women's performance on the Mental Rotations Test. 31 men and 59 women enrolled at a small, private church-affiliated university and majoring in art or music as well as students who participated in intercollegiate athletics completed the Mental Rotations Test. Women's scores on the Mental Rotations Test benefitted from experience with spatial activities; the more types of experience the women had, the better their scores. Thus women who were athletes, musicians, or artists scored better than those women who had no experience with these activities. The opposite results were found for the men. Efforts are currently underway to assess how length of experience and which types of experience are related to scores.

  10. Divide and Conquer-Based 1D CNN Human Activity Recognition Using Test Data Sharpening.

    Science.gov (United States)

    Cho, Heeryon; Yoon, Sang Min

    2018-04-01

    Human Activity Recognition (HAR) aims to identify the actions performed by humans using signals collected from various sensors embedded in mobile devices. In recent years, deep learning techniques have further improved HAR performance on several benchmark datasets. In this paper, we propose one-dimensional Convolutional Neural Network (1D CNN) for HAR that employs a divide and conquer-based classifier learning coupled with test data sharpening. Our approach leverages a two-stage learning of multiple 1D CNN models; we first build a binary classifier for recognizing abstract activities, and then build two multi-class 1D CNN models for recognizing individual activities. We then introduce test data sharpening during prediction phase to further improve the activity recognition accuracy. While there have been numerous researches exploring the benefits of activity signal denoising for HAR, few researches have examined the effect of test data sharpening for HAR. We evaluate the effectiveness of our approach on two popular HAR benchmark datasets, and show that our approach outperforms both the two-stage 1D CNN-only method and other state of the art approaches.

  11. Divide and Conquer-Based 1D CNN Human Activity Recognition Using Test Data Sharpening

    Directory of Open Access Journals (Sweden)

    Heeryon Cho

    2018-04-01

    Full Text Available Human Activity Recognition (HAR aims to identify the actions performed by humans using signals collected from various sensors embedded in mobile devices. In recent years, deep learning techniques have further improved HAR performance on several benchmark datasets. In this paper, we propose one-dimensional Convolutional Neural Network (1D CNN for HAR that employs a divide and conquer-based classifier learning coupled with test data sharpening. Our approach leverages a two-stage learning of multiple 1D CNN models; we first build a binary classifier for recognizing abstract activities, and then build two multi-class 1D CNN models for recognizing individual activities. We then introduce test data sharpening during prediction phase to further improve the activity recognition accuracy. While there have been numerous researches exploring the benefits of activity signal denoising for HAR, few researches have examined the effect of test data sharpening for HAR. We evaluate the effectiveness of our approach on two popular HAR benchmark datasets, and show that our approach outperforms both the two-stage 1D CNN-only method and other state of the art approaches.

  12. Divide and Conquer-Based 1D CNN Human Activity Recognition Using Test Data Sharpening †

    Science.gov (United States)

    Yoon, Sang Min

    2018-01-01

    Human Activity Recognition (HAR) aims to identify the actions performed by humans using signals collected from various sensors embedded in mobile devices. In recent years, deep learning techniques have further improved HAR performance on several benchmark datasets. In this paper, we propose one-dimensional Convolutional Neural Network (1D CNN) for HAR that employs a divide and conquer-based classifier learning coupled with test data sharpening. Our approach leverages a two-stage learning of multiple 1D CNN models; we first build a binary classifier for recognizing abstract activities, and then build two multi-class 1D CNN models for recognizing individual activities. We then introduce test data sharpening during prediction phase to further improve the activity recognition accuracy. While there have been numerous researches exploring the benefits of activity signal denoising for HAR, few researches have examined the effect of test data sharpening for HAR. We evaluate the effectiveness of our approach on two popular HAR benchmark datasets, and show that our approach outperforms both the two-stage 1D CNN-only method and other state of the art approaches. PMID:29614767

  13. Test-retest reliability of a questionnaire to assess physical environmental factors pertaining to physical activity

    Directory of Open Access Journals (Sweden)

    McGinn Aileen P

    2005-06-01

    Full Text Available Abstract Background Despite the documented benefits of physical activity, many adults do not obtain the recommended amounts. Barriers to physical activity occur at multiple levels, including at the individual, interpersonal, and environmental levels. Only until more recently has there been a concerted focus on how the physical environment might affect physical activity behavior. With this new area of study, self-report measures should be psychometrically tested before use in research studies. Therefore the objective of this study was to document the test-retest reliability of a questionnaire designed to assess physical environmental factors that might be associated with physical activity in a diverse adult population. Methods Test and retest surveys were conducted over the telephone with 106 African American and White women and men living in either Forsyth County, North Carolina or Jackson, Mississippi. Reliability of self-reported environmental factors across four domains (e.g., access to facilities and destinations, functionality and safety, aesthetics, natural environment was determined using intraclass correlation coefficients (ICC overall and separately by gender and race. Results Generally items displayed moderate and sometimes substantial reliability (ICC between 0.4 to 0.8, with a few differences by gender or race, across each of the domains. Conclusion This study provides some psychometric evidence for the use of many of these questions in studies examining the effect of self-reported physical environmental measures on physical activity behaviors, among African American and White women and men.

  14. Identification of prefrontal cortex (BA10) activation while performing Stroop test using diffuse optical tomography

    Science.gov (United States)

    Khadka, Sabin; Chityala, Srujan R.; Tian, Fenghua; Liu, Hanli

    2011-03-01

    Stroop test is commonly used as a behavior-testing tool for psychological examinations that are related to attention and cognitive control of the human brain. Studies have shown activations in Broadmann area 10 (BA10) of prefrontal cortex (PFC) during attention and cognitive process. The use of diffuse optical tomography (DOT) for human brain mapping is becoming more prevalent. In this study we expect to find neural correlates between the performed cognitive tasks and hemodynamic signals detected by a DOT system. Our initial observation showed activation of oxy-hemoglobin concentration in BA 10, which is consistent with some results seen by positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). Our study demonstrates the possibility of combining DOT with Stroop test to quantitatively investigate cognitive functions of the human brain at the prefrontal cortex.

  15. Design and Test of Semi-Active Vibration-Reducing System for Lathe

    Directory of Open Access Journals (Sweden)

    Hongsheng Hu

    2014-09-01

    Full Text Available In this paper, its theory design, analysis and test system of semi-active vibration controlling system used for precision machine have been done. Firstly, lathe bed and spindle entity were modeled by using UG software; Then modes of the machine bed and the key components of spindle were obtained by using ANSYS software; Finally, harmonic response analysis of lathe spindle under complex load was acquired, which provided a basis of MR damper’s structure optimization design for a certain type of precision machine. In order to prove its effectives, a prototype semi-active vibration controlling lathe with MR damper was developed. Tests have been done, and comparison results between passive vibration isolation equipment and semi-active vibration controlling equipment proved its good performances of MR damper.

  16. Engineering analysis activities in support of susquehanna unit 1 startup testing and cycle 1 operations

    International Nuclear Information System (INIS)

    Miller, G.D.; Kukielka, C.A.; Olson, L.M.; Refling, J.G.; Roscioli, A.J.; Somma, S.A.

    1985-01-01

    The engineering analysis group is responsible for all nuclear plant systems analysis and reactor analysis activities, excluding fuel management analysis, at Pennsylvania Power and Light Company. These activities include making pretest and posttest predictions of startup tests; analyzing unplanned or unexpected transient events; providing technical training to plant personnel; assisting in the development of emergency drill scenarios; providing engineering evaluations to support design and technical specification changes, and evaluating, assessing, and resolving a number of license conditions. Many of these activities have required the direct use of RETRAN models. Two RETRAN analyses that were completed to support plant operations - a pretest analysis of the turbine trip startup test, and a posttest analysis of the loss of startup transformer event - are investigated. For each case, RETRAN results are compared with available plant data and comparisons are drawn on the acceptability of the performance of the plant systems

  17. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    Science.gov (United States)

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Usefulness of Basophil Activation Tests for Diagnosis of Sugammadex-Induced Anaphylaxis.

    Science.gov (United States)

    Horiuchi, Tatsuo; Yokohama, Akihiko; Orihara, Masaki; Tomita, Yukinari; Tomioka, Akihiro; Yoshida, Nagahide; Takahashi, Kenichiro; Saito, Shigeru; Takazawa, Tomonori

    2018-05-01

    Sugammadex is used to reverse the effects of neuromuscular blocking agents in many cases of general anesthesia. However, there are several reports of anaphylaxis after its use. Skin testing is the gold standard for detecting the causative agent of anaphylaxis. However, due to the lack of validated protocols for skin testing with sugammadex, the diagnostic accuracy might be inadequate. Recently, the basophil activation test (BAT) has been established as a tool to detect the causative agent of anaphylaxis with high sensitivity and specificity. However, few studies have investigated the utility of the BAT for sugammadex-induced anaphylaxis. Eight patients who presented with immediate hypersensitivity to sugammadex during general anesthesia were included in this study. We conducted skin tests to confirm the diagnosis of sugammadex-induced anaphylaxis. Twenty-one sugammadex-naive individuals who had a negative skin test for allergy to this drug were enrolled as controls. Basophils were selected on a CD3/CRTH2 gate and labeled with CD63 and CD203c. The ratios of activated basophils in the patients were much higher than those in controls: the median values of areas under the curves in the patients and controls for CD203c were 1,265,985 (95% confidence interval [CI], 77,580-5,040,270) and 116,325 (95% CI, -268,605 to 232,690), respectively (Mann-Whitney U test, P sugammadex was 88% (95% CI, 47%-100%), and specificity was 100% (95% CI, 84%-100%), while sensitivity and specificity for CD63 were 75% (95% CI, 35%-97%) and 100% (95% CI, 84%-100%), respectively. The BAT seems to have comparable accuracy to skin tests for the diagnosis of sugammadex-induced anaphylaxis. For this purpose, both CD203c and CD63 can be used to detect activated basophils.

  19. Omega-3 fatty acids have antidepressant activity in forced swimming test in Wistar rats.

    Science.gov (United States)

    Lakhwani, Lalit; Tongia, Sudheer K; Pal, Veerendra S; Agrawal, Rajendra P; Nyati, Prem; Phadnis, Pradeep

    2007-01-01

    Forced swimming test is used to induce a characteristic behavior of immobility in rats, which resembles depression in humans to some extent. We evaluated the effect of omega-3 fatty acids alone as well as compared it with the standard antidepressant therapy with fluoxetine in both acute and chronic studies. In both the studies, rats were divided into 4 groups and subjected to the following drug interventions - Group 1- control: Group 2- fluoxetine in dose of 10 mg/kg subcutaneously 23.5, 5 and 1 h before the test: Group 3- omega-3 fatty acids in dose of 500 mg/kg orally; Group 4- fluoxetine plus omega-3 fatty acids both. In acute study, omega-3 fatty acids were given in single dose 2 h prior to the test while in chronic study omega-3 fatty acids were given daily for a period of 28 days. All animals were subjected to a 15-min pretest followed 24 h later by a 5-min test. A time sampling method was used to score the behavioral activity in each group. The results revealed that in acute study, omega-3 fatty acids do not have any significant effect in forced swimming test. However, in chronic study, omega-3 fatty acids affect the immobility and swimming behavior significantly when compared with control (p fluoxetine is significantly more than that of fluoxetine alone in changing the behavioral activity of rats in forced swimming test. It leads to the conclusion that omega-3 fatty acids have antidepressant activity per se, and the combination of fluoxetine and omega-3 fatty acids has more antidepressant efficacy than fluoxetine alone in forced swimming test in Wistar rats.

  20. [Testing the pharmacological activity of some synthetic cannabinoids in mice (author's transl)].

    Science.gov (United States)

    Ganz, A J; Waser, P G

    1980-01-01

    A series of synthetic cannabinoids were tested in mice for analgesic, anticonvulsant, sedative and reserpine antagonistic properties as well as for influence on body temperature and on motor coordination and compared with the natural delta 9-tetrahydrocannabinol (delta 9-THC), delta 8-tetrahydrocannabinol (delta 8-THC) and cannabidiol (CBD). All cannabinoids were injected s.c. or i.p. in mice as solutions in olive oil. The synthetic cannabinoids, with the exception of the lipophilic ones, were less active than the natural delta 9-THC. 1',1'-dimethyl-delta 8-tetrahydrocannabinol (DM-delta 8-THC) has an analgesic ED 50 of 16 mg/kg s.c. (writhing test) and is three times more active than delta 9-THC, but also eight times less active than morphine. The lipophilic derivatives of delta 8-THC prolonged pentobarbitone narcosis and diminished locomotor activity in mice. Anticonvulsant activities could never be detected; all cannabinoids slightly diminished body temperature and antagonized weakly the hypothermia induced by reserpine. The trained capacity of remaining on the rotating rod was severely shortened for a long time after application of all cannabinoids but mainly by the lipophilic ones. The influence of derivation on the activity of delta 9-THC is discussed.

  1. Hover Testing of the NASA/Army/MIT Active Twist Rotor Prototype Blade

    Science.gov (United States)

    Wilbur, Matthew L.; Yeager, William T., Jr.; Wilkie, W. Keats; Cesnik, Carlos E. S.; Shin, Sangloon

    2000-01-01

    Helicopter rotor individual blade control promises to provide a mechanism for increased rotor performance and reduced rotorcraft vibrations and noise. Active material methods, such as piezoelectrically actuated trailing-edge flaps and strain-induced rotor blade twisting, provide a means of accomplishing individual blade control without the need for hydraulic power in the rotating system. Recent studies have indicated that controlled strain induced blade twisting can be attained using piezoelectric active fiber composite technology. In order to validate these findings experimentally, a cooperative effort between NASA Langley Research Center, the Army Research Laboratory, and the MIT Active Materials and Structures Laboratory has been developed. As a result of this collaboration an aeroelastically-scaled active-twist model rotor blade has been designed and fabricated for testing in the heavy gas environment of the Langley Transonic Dynamics Tunnel (TDT). The results of hover tests of the active-twist prototype blade are presented in this paper. Comparisons with applicable analytical predictions of active-twist frequency response in hovering flight are also presented.

  2. A universal suspension test rig for electrohydraulic active and passive automotive suspension system

    Directory of Open Access Journals (Sweden)

    Mahmoud Omar

    2017-12-01

    Full Text Available A fully active electro-hydraulic and passive automotive quarter car suspensions with their experimental test-rigs are designed and implemented. Investigation of the active performance compared against the passive is performed experimentally and numerically utilizing SIMULINK's Simscape library. Both systems are modeled as single-degree-of-freedom in order to simplify the validation process. Economic considerations were considered during the rig's implementation. The rig consists of two identical platforms fixed side by side allowing testing two independent suspensions simultaneously. Position sensors for sprung and unsprung masses on both platforms are installed. The road input is introduced by a cam and a roller follower mechanism driven by 1.12 kW single phase induction motor with speed reduction assembly. The active hydraulic cylinder was the most viable choice due to its high power-to-weight ratio. The active control is of the proportional-integral-differential (PID type. Though this technique is quite simple and not new, yet the emphasis of this paper is the engineering, design and implementation of the experimental setup and controller. A successful validation process is performed. Ride comfort significantly improved with active suspension, as shown by the results; 24.8% sprung mass vibration attenuation is achieved. The details of the developed system with the analytical and experimental results are presented. Keywords: Active suspension, Passive suspension, Servo, Hydraulic, Control, PID

  3. Wing Torsional Stiffness Tests of the Active Aeroelastic Wing F/A-18 Airplane

    Science.gov (United States)

    Lokos, William A.; Olney, Candida D.; Crawford, Natalie D.; Stauf, Rick; Reichenbach, Eric Y.

    2002-01-01

    The left wing of the Active Aeroelastic Wing (AAW) F/A-18 airplane has been ground-load-tested to quantify its torsional stiffness. The test has been performed at the NASA Dryden Flight Research Center in November 1996, and again in April 2001 after a wing skin modification was performed. The primary objectives of these tests were to characterize the wing behavior before the first flight, and provide a before-and-after measurement of the torsional stiffness. Two streamwise load couples have been applied. The wing skin modification is shown to have more torsional flexibility than the original configuration has. Additionally, structural hysteresis is shown to be reduced by the skin modification. Data comparisons show good repeatability between the tests.

  4. Activation analysis of Chinese ITER helium cooled solid breeder test blanket module

    International Nuclear Information System (INIS)

    Han Jingru; Chen Yixue; Ma Xubo; Wang Shouhai; Forrest, R.A.

    2009-01-01

    Based on the Chinese ITER helium cooled solid breeder(CH-HCSB) test blanket module (TBM) of the 3 x 6 sub-modules options, the activation characteristics of the TBM were calculated. Three-dimensional neutronic calculations were performed using the Monte-Carlo code MCNP and the nuclear data library FENDL/2. Furthermore, the activation calculations of HCSB-TBM were carried out with the European activation system EASY-2007. At shutdown the total activity is 1.29 x 10 16 Bq, and the total afterheat is 2.46 kW. They are both dominated by the Eurofer steel. The activity and afterheat are both in the safe range of TBM design, and will not have a great impact on the environment. Meanwhile,on basis of the calculated contact dose rate, the activated materials can be re-used following the remote handling recycling options. The activation results demonstrate that the current HCSB-TBM design can satisfy the ITER safety design requirements from the activation point of view. (authors)

  5. Lead Testing in Soil Contaminated with Pesticides and Reducing its Effects by the Activity of Activated Charcoal

    Directory of Open Access Journals (Sweden)

    Devesh Chand Thakur

    2014-07-01

    Full Text Available Background: Lead poisoning is classically defined as exposure to high levels of lead typically associated with severe health effects, but being a heavy metal which is potentially toxic, if present at even minor concentrations, it is of great concern to environmentalists and medical professionals alike. Activated charcoal has been known to adsorb heavy metals and thus, was used in this study as well. Aim: The main aim of this study was to decrease the lead content of agricultural soil which is attributed to the use of pesticides containing lead by using activated charcoal. Material and Methods: The lead contamination in agricultural soil and plant dry mass samples which increases due to the effect of pesticides was detected by using Field Portable X-Ray Fluroscence (FP-XRF spectrophotometer. Soil was taken in plastic trays and the plants were grown and watered daily. The collected ground water was also tested. For the estimation of lead in water samples, Graphite Furnace Atomic Absorption Spectroscopy (GFAAS was employed. Results: This study suggested the remediation of soil lead content by using activated charcoal. The study also revealed that activated charcoal not only adsorbs lead but also inhibits the accumulation of lead in ground water. Conclusion: This study promotes a cost effective process to treat agricultural lands polluted with leaded pesticides. Water purifiers, refrigerator etc. contain varying amounts of activated charcoal, after usage of these appliances it can be recycled and used as a source of activated charcoal. This can be applied in pesticide contaminated fields either in the form of slurry or by spraying.

  6. Plasma exchange to remove HIT antibodies: dissociation between enzyme-immunoassay and platelet activation test reactivities.

    Science.gov (United States)

    Warkentin, Theodore E; Sheppard, Jo-Ann I; Chu, F Victor; Kapoor, Anil; Crowther, Mark A; Gangji, Azim

    2015-01-01

    Repeated therapeutic plasma exchange (TPE) has been advocated to remove heparin-induced thrombocytopenia (HIT) IgG antibodies before cardiac/vascular surgery in patients who have serologically-confirmed acute or subacute HIT; for this situation, a negative platelet activation assay (eg, platelet serotonin-release assay [SRA]) has been recommended as the target serological end point to permit safe surgery. We compared reactivities in the SRA and an anti-PF4/heparin IgG-specific enzyme immunoassay (EIA), testing serial serum samples in a patient with recent (subacute) HIT who underwent serial TPE precardiac surgery, as well as for 15 other serially-diluted HIT sera. We observed that post-TPE/diluted HIT sera-when first testing SRA-negative-continue to test strongly positive by EIA-IgG. This dissociation between the platelet activation assay and a PF4-dependent immunoassay for HIT antibodies indicates that patients with subacute HIT undergoing repeated TPE before heparin reexposure should be tested by serial platelet activation assays even when their EIAs remain strongly positive. © 2015 by The American Society of Hematology.

  7. Antioxidant, Antibacterial activity and Brine shrimp toxicity test of some Mountainous Lichens from Nepal

    Directory of Open Access Journals (Sweden)

    Babita Paudel

    2012-01-01

    Full Text Available A total of twenty four lichen species belonging to six families were collected from mountainous region of Nepal. The methanol extracts of each species were tested for antimicrobial and antioxidant activitiesin vitro. It was found that extracts of twenty one lichen species were active againstB. subtilis and seven species were active againstS. aureus. Similarly, in DPPH assay, three speciesPeltigera sp.,Cladonia sp., andCanoparmelia sp. showed comparable activity with commercial standard, BHA. In ABTS+ assay, extracts ofParmoterma sp.,Ramalina sp.,Peltigera sp. andCladonia sp. showed stronger activity than ascorbic acid. The observed data after comparison with previously published reports indicated that the high altitude lichens contain stronger antioxidant and antibacterial constituents. Similarly, the methanol extracts ofHeterodermia sp. andRamalina sp. showed comparable toxicity effect with commercial standard berberine chloride indicating a potent source of anticancer drugs.

  8. Motivation towards extracurricular activities and motivation at school: A test of the generalization effect hypothesis.

    Science.gov (United States)

    Denault, Anne-Sophie; Guay, Frédéric

    2017-01-01

    Participation in extracurricular activities is a promising avenue for enhancing students' school motivation. Using self-determination theory (Deci & Ryan, 2000), the goal of this study was to test a serial multiple mediator model. In this model, students' perceptions of autonomy support from their extracurricular activity leader predicted their activity-based intrinsic and identified regulations. In turn, these regulations predicted their school-based intrinsic and identified regulations during the same school year. Finally, these regulations predicted their school-based intrinsic and identified regulations one year later. A total of 276 youths (54% girls) from disadvantaged neighborhoods were surveyed over two waves of data collection. The proposed mediation model was supported for both types of regulation. These results highlight the generalization effects of motivation from the extracurricular activity context to the school context. Copyright © 2016 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  9. The development and testing of a modular containment system under plutonium active conditions

    International Nuclear Information System (INIS)

    Sanders, M.J.; Pengelly, M.G.A.

    1984-05-01

    A Modular Containment System has been designed, constructed and tested under plutonium active conditions at AEE Winfrith. The unit consists of a portable self-contained pressurised suit area, complete with shower entry tunnel and ventilation plant which can be assembled to enclose active plant to enable active operations to be carried out safely by operators dressed in standard pressurised suits. A fundamental feature of the system is the use of strippable coatings which are used to treat the interior surfaces prior to active operations to prevent permanent contamination of the structure. Details of construction are given together with results of trials. Whilst this report describes work with plutonium, the system has clear applications wherever temporary containment of radioactive or toxic materials is needed. (U.K.)

  10. Use of bioassays for testing soils and/or sediments contaminated by mining activities

    Science.gov (United States)

    Pérez-Sirvent, C.; Martínez-Sánchez, M. J.; García-Lorenzo, M. L.; Molina, J.

    2009-04-01

    Ecotoxicity tests measure the bioavailability of the contaminants and the effects of the chemically not measured toxic compounds on the members of the soil community. Therefore, ecotoxicological testing may be a useful approach for assessing the toxicity as a complement to chemical analysis. They are solid phase tests based on terrestrial methods and tests performed on water extracts using aquatic test protocols. The extent and degree of heavy metal contamination around mines may vary depending on geochemical characteristics, the mineralization of tailings, physico-chemical conditions and the processes used to extract metals. Portman Bay was subject to mining from the time of the Roman Empire to 1991 when the activity ceased. Since 1957, the wastes from mining operations were discharged directly into the sea. These wastes mainly consisted of clay, quartz, siderite, magnetite, remains of sphalerite, pyrite and galena and residues of the chemical reagents used in floatation. In our study two methods of environmental toxicological tests were compared and applied to sediments of the Portman Bay (SE, Spain): the standardized toxicological test based on inhibition of luminescence employing Microtox

  11. Negativization rates of IgE radioimmunoassay and basophil activation test in immediate reactions to penicillins.

    Science.gov (United States)

    Fernández, T D; Torres, M J; Blanca-López, N; Rodríguez-Bada, J L; Gomez, E; Canto, G; Mayorga, C; Blanca, M

    2009-02-01

    Skin test sensitivity in patients with immediate allergy to penicillins tends to decrease over time, but no information is available concerning in vitro tests. We analysed the negativization rates of two in vitro methods that determine specific immunoglobulin E (IgE) antibodies, the basophil activation test using flow cytometry (BAT) and the radioallergosorbent test (RAST), in immediate allergic reactions to penicillins. Forty-one patients with immediate allergic reactions to amoxicillin were followed up over a 4-year period. BAT and RAST were performed at 6-month intervals. Patients were randomized into groups: Group I, skin tests carried out at regular intervals; Group II, skin tests made only at the beginning of the study. Differences were observed between RAST and BAT (P testing influenced the rate of negativization of the RAST assay, contributing to maintenance of in vitro sensitivity. Because of the loss of sensitivity over time, the determination of specific IgE antibodies to penicillins in patients with immediate allergic reactions must be done as soon as possible after the reaction.

  12. Flight Test of the F/A-18 Active Aeroelastic Wing Airplane

    Science.gov (United States)

    Voracek, David

    2007-01-01

    A viewgraph presentation of flight tests performed on the F/A active aeroelastic wing airplane is shown. The topics include: 1) F/A-18 AAW Airplane; 2) F/A-18 AAW Control Surfaces; 3) Flight Test Background; 4) Roll Control Effectiveness Regions; 5) AAW Design Test Points; 6) AAW Phase I Test Maneuvers; 7) OBES Pitch Doublets; 8) OBES Roll Doublets; 9) AAW Aileron Flexibility; 10) Phase I - Lessons Learned; 11) Control Law Development and Verification & Validation Testing; 12) AAW Phase II RFCS Envelopes; 13) AAW 1-g Phase II Flight Test; 14) Region I - Subsonic 1-g Rolls; 15) Region I - Subsonic 1-g 360 Roll; 16) Region II - Supersonic 1-g Rolls; 17) Region II - Supersonic 1-g 360 Roll; 18) Region III - Subsonic 1-g Rolls; 19) Roll Axis HOS/LOS Comparison Region II - Supersonic (open-loop); 20) Roll Axis HOS/LOS Comparison Region II - Supersonic (closed-loop); 21) AAW Phase II Elevated-g Flight Test; 22) Region I - Subsonic 4-g RPO; and 23) Phase II - Lessons Learned

  13. Domestic activity for technical development of the APR1400's RCP performance test

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Kim, Seok; Bae, Byung-Uhn; Cho, Yun-Jae; Kim, Yeon-Sik; Jeon, Woo-Jin; Yun, Young-Jung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The thermal hydraulic and electric capability of the RCP test facility (RCPTF) covers up to 18.5 MPa, 343 .deg. C, 11.7 m{sup 3}/s, and 14.0 MW in the design pressure, temperature, flow rate, and the maximum electric power, respectively. In 2013, commissioning test had been performed to verify its designed capability, followed by several modifications in the RCPTF including signal processing and control logic to enhance verification and evaluation capability of the RCP performance. After finishing the commissioning and modification of the RCPTF, type test for the new-type RCP had been performed successfully. In this paper, several technical issues developed in the 2013 and the type test's method and results will be described. In the present paper, the technical activities for the development of the verification test of APR1400's RCP are described. KAERI has completed the full set of technology development, prerequisite for the RCP verification test, and now on the way to perform a test for the sealing capacity of the seal assembly during the Station Block Out (SBO) condition of APR1400.

  14. Integral test on activation cross section of tag gas nuclides using fast neutron spectrum fields

    Energy Technology Data Exchange (ETDEWEB)

    Aoyama, Takafumi; Suzuki, Soju [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-03-01

    Activation cross sections of tag gas nuclides, which will be used for the failed fuel detection and location in FBR plants, were evaluated by the irradiation tests in the fast neutron spectrum fields in JOYO and YAYOI. The comparison of their measured radioactivities and the calculated values using the JENDL-3.2 cross section set showed that the C/E values ranged from 0.8 to 2.8 for the calibration tests in YAYOI and that the present accuracies of these cross sections were confirmed. (author)

  15. Calibration and performance testing of the IAEA Aquila Active Well Coincidence Counter (Unit 1)

    International Nuclear Information System (INIS)

    Menlove, H.O..; Siebelist, R.; Wenz, T.R.

    1996-01-01

    An Active Well Coincidence Counter (AWCC) and a portable shift register (PSR-B) produced by Aquila Technologies Group, Inc., have been tested and cross-calibrated with existing AWCCs used by the International Atomic Energy Agency (IAEA). This report summarizes the results of these tests and the cross-calibration of the detector. In addition, updated tables summarizing the cross-calibration of existing AWCCs and AmLi sources are also included. Using the Aquila PSR-B with existing IAEA software requires secondary software also supplied by Aquila to set up the PSR-B with the appropriate measurement parameters

  16. Active tower damping and pitch balancing – design, simulation and field test

    International Nuclear Information System (INIS)

    Duckwitz, Daniel; Shan, Martin

    2014-01-01

    The tower is one of the major components in wind turbines with a contribution to the cost of energy of 8 to 12% [1]. In this overview the load situation of the tower will be described in terms of sources of loads, load components and fatigue contribution. Then two load reduction control schemes are described along with simulation and field test results. Pitch Balancing is described as a method to reduce aerodynamic asymmetry and the resulting fatigue loads. Active Tower Damping is reducing the tower oscillations by applying appropiate pitch angle changes. A field test was conducted on an Areva M5000 wind turbine

  17. Active tower damping and pitch balancing - design, simulation and field test

    Science.gov (United States)

    Duckwitz, Daniel; Shan, Martin

    2014-12-01

    The tower is one of the major components in wind turbines with a contribution to the cost of energy of 8 to 12% [1]. In this overview the load situation of the tower will be described in terms of sources of loads, load components and fatigue contribution. Then two load reduction control schemes are described along with simulation and field test results. Pitch Balancing is described as a method to reduce aerodynamic asymmetry and the resulting fatigue loads. Active Tower Damping is reducing the tower oscillations by applying appropiate pitch angle changes. A field test was conducted on an Areva M5000 wind turbine.

  18. Design, realization and testing of an adsorption refrigerator based on activated carbon/ethanol working pair

    International Nuclear Information System (INIS)

    Frazzica, A.; Palomba, V.; Dawoud, B.; Gullì, G.; Brancato, V.; Sapienza, A.; Vasta, S.; Freni, A.; Costa, F.; Restuccia, G.

    2016-01-01

    Highlights: • Development of a lab-scale adsorption refrigerator. • Optimization of working pair and adsorber configuration through experimental activity. • Experimental testing of the prototype under real working boundary conditions. - Abstract: In the present paper design, realization and testing of a novel small scale adsorption refrigerator prototype based on activated carbon/ethanol working pair is described. Firstly, experimental activity has been carried out for identification of the best performing activated carbon available on the market, through the evaluation of the achievable thermodynamic performance both under air conditioning and refrigeration conditions. Once identified the best performing activated carbon, the design of the adsorber was developed by experimental dynamic performance analysis, carried out by means of the Gravimetric-Large Temperature Jump (G-LTJ) apparatus available at CNR ITAE lab. Finally, the whole 0.5 kW refrigerator prototype was designed and built. First experimental results both under reference air conditioning and refrigeration cycles have been reported, to check the achievable performance. High Specific Cooling Powers (SCPs), 95 W/kg and 50 W/kg, for air conditioning and refrigeration respectively, were obtained, while the COP ranged between 0.09 and 0.11, thus showing an improvement of the current state of the art.

  19. Detailed measurements and modelling of thermo active components using a room size test facility

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Svendsen, Svend

    2005-01-01

    measurements in an office sized test facility with thermo active ceiling and floor as well as modelling of similar conditions in a computer program designed for analysis of building integrated heating and cooling systems. A method for characterizing the cooling capacity of thermo active components is described...... typically within 1-2K of the measured results. The simulation model, whose room model splits up the radiative and convective heat transfer between room and surfaces, can also be used to predict the dynamical conditions, where especially the temperature rise during the day is important for designing...

  20. Relationships Among Two Repeated Activity Tests and Aerobic Fitness of Volleyball Players.

    Science.gov (United States)

    Meckel, Yoav; May-Rom, Moran; Ekshtien, Aya; Eisenstein, Tamir; Nemet, Dan; Eliakim, Alon

    2015-08-01

    The purpose of the study was to determine performance indices of a repeated sprint test (RST) and to examine their relationships with performance indices of a repeated jump test (RJT) and with aerobic fitness among trained volleyball players. Sixteen male volleyball players performed RST (6 × 30 m sprints), RJT (6 sets of 6 consecutive jumps), and an aerobic power test (20-m Shuttle Run Test). Performance indices for the RST and the RJT were (a) the ideal 30-m run time (IS), the total run time (TS) of the 6 sprints, and the performance decrement (PD) during the test and (b) the ideal jump height (IJ), the total jump height (TJ) of all the jumps, and the PD during the test, respectively. No significant correlations were found between performance indices of the RST and RJT. Significant correlations were found between PD, IS, and TS in the RST protocol and predicted peak V[Combining Dot Above]O2 (r = -0.60, -0.75, -0.77, respectively). No significant correlations were found between performance indices of the RJT (IJ, TJ, and PD) and peak V[Combining Dot Above]O2. The findings suggest that a selection of repeated activity test protocols should acknowledge the specific technique used in the sport, and that a distinct RJT, rather than the classic RST, is more appropriate for assessing the anaerobic capabilities of volleyball players. The findings also suggest that aerobic fitness plays only a minor role in performance maintenance throughout characteristic repeated jumping activity of a volleyball game.

  1. Seismic functional qualification of active mechanical and electrical components based on shaking table testing

    International Nuclear Information System (INIS)

    Jurukovski, D.

    1999-01-01

    The seismic testing for qualification of one sample of the NPP Kozloduy Control Panel type YKTC was carried out under Research Contract no: 8008/Rl, entitled: 'Seismic Functional Qualification of Active Mechanical and Electrical Components Based on Shaking Table Testing'. The tested specimen was selected by the Kozloduy NPP staff, Section 'TIA-2' (Technical Instrumentation and Automatics), however the seismic input parameters were selected by the NPP Kozloduy staff, Section HTS and SC (Hydro-Technical Systems and Engineering Structures). The applied methodology was developed by the Institute of Earthquake Engineering and Engineering Seismology staff. This report presents all relevant items related to the selected specimen seismic testing for seismic qualification such as: description of the tested specimen, mounting conditions on the shaking table, selection of seismic input parameters and creation of seismic excitations, description of the testing equipment, explanation of the applied methodology, 'on line' and 'off line' monitoring of the tested specimen, functioning capabilities, discussion of the results and their presentation and finally conclusions and recommendations. In this partial project report, two items are presented. The first item presents a review of the existing and used regulations for performing of the seismic and vibratory withstand testing of electro-mechanical equipment. The selection is made based on MEA, IEEE, IEC and former Soviet Union regulations. The second item presents the abstracts of all the tests performed at the Institute of Earthquake Engineering and Engineering Seismology in Skopje. The selected regulations, the experience of the Institute that has been gathered for the last seventeen years and some theoretical and experimental research will be the basis for further investigations for development of a synthesised methodology for seismic qualification of differently categorized equipment for nuclear power plants

  2. Testing a user-driven approach in health promotion activities targeting users of psychiatric services

    DEFF Research Database (Denmark)

    Folmann Hempler, Nana; Saurbrey Pals, Regitze; Oest, Lone

    2017-01-01

    Compared to the general population, users of psychiatric services (users) are at higher risk of developing type 2 diabetes, which is associated with lifestyle behaviours. The aim of this study was to pilot test a new collaborative approach in health promotion targeting users. The approach is based...... with course participants and users. Professionals had to test at least one tool in a health promoting activity such as health checks, exercise etc. Data were collected through observations of health promoting activities (n=15) and questionnaires (n=54). Data were analysed using systematic text condensation...... and descriptive statistics. The majority of professionals found that the new approach to a moderate/high degree had improved their collaborative skills (89.3%) and Research Center of Health Promotionwas well-suited for their practice (93.5%). Observations showed that professionals successfully integrated...

  3. [Unpredictable chronic mild stress effects on antidepressants activities in forced swim test].

    Science.gov (United States)

    Kudryashov, N V; Kalinina, T S; Voronina, T A

    2015-02-01

    The experiments has been designed to study unpredictable chronic mild stress effect on anti-depressive activities of amitriptyline (10 mg/kg) and fluoxetine (20 mg/kg) in forced swim test in male outbred mice. It is shown that acute treatment with fluoxetine does not produce any antidepressant effects in mice following stress of 14 days while the sub-chronic injections of fluoxetine result in more deep depressive-like behavior. In 28 daily stressed mice, antidepressant effect of fluoxetine is observed independently of the injection rates. Amitriptyline demonstrates the antidepressant activity regardless of the duration of stress or administration scheduling, but at the same time the severity of anti-immobilization effect of amitriptyline in stressed mice is weaker in compare to non-stressed trails. Thus, the injection rates and duration of unpredictable mild chronic stress are the parameters that determine the efficiency of antidepressants in the mouse forced swimming test.

  4. Cueing vocabulary during sleep increases theta activity during later recognition testing.

    Science.gov (United States)

    Schreiner, Thomas; Göldi, Maurice; Rasch, Björn

    2015-11-01

    Neural oscillations in the theta band have repeatedly been implicated in successful memory encoding and retrieval. Several recent studies have shown that memory retrieval can be facilitated by reactivating memories during their consolidation during sleep. However, it is still unknown whether reactivation during sleep also enhances subsequent retrieval-related neural oscillations. We have recently demonstrated that foreign vocabulary cues presented during sleep improve later recall of the associated translations. Here, we examined the effect of cueing foreign vocabulary during sleep on oscillatory activity during subsequent recognition testing after sleep. We show that those words that were replayed during sleep after learning (cued words) elicited stronger centroparietal theta activity during recognition as compared to noncued words. The reactivation-induced increase in theta oscillations during later recognition testing might reflect a strengthening of individual memory traces and the integration of the newly learned words into the mental lexicon by cueing during sleep. © 2015 Society for Psychophysiological Research.

  5. Passive characterization and active testing of epoxy bonded regenerators for room temperature magnetic refrigeration

    DEFF Research Database (Denmark)

    Lei, Tian; Navickaité, Kristina; Engelbrecht, Kurt

    2017-01-01

    -layer AMR based on spherical particles is tested actively in a small reciprocating magnetic refrigerator, achieving a no-load temperature span of 16.8 °C using about 143 g of epoxy-bonded La(Fe,Mn,Si)13Hy materials. Simulations based on a one-dimensional (1D) AMR model are also implemented to validate......Epoxy bonded regenerators of both spherical and irregular La(Fe,Mn,Si)13Hy particles have been developed aiming at increasing the mechanical strength of active magnetic regenerators (AMR) loaded with brittle magnetocaloric materials and improving the flexibility of shaping the regenerator geometry....... Although the magnetocaloric properties of these materials are well studied, the flow and heat transfer characteristics of the epoxy bonded regenerators have seldom been investigated. This paper presents a test apparatus that passively characterizes regenerators using a liquid heat transfer fluid...

  6. Testing methods for antimicrobial activity of TiO2 photocatalyst

    Directory of Open Access Journals (Sweden)

    Markov Siniša L.

    2014-01-01

    Full Text Available In recent years, a lot of commercial TiO2 photocatalyst products have been developed and extensively studied for prospective and safe antimicrobial application in daily life, medicine, laboratories, food and pharmaceutical industry, waste water treatments and in development of new self-cleaning and antimicrobial materials, surfaces and paints. This paper reviews the studies published worldwide on killing microorganisms, methods for testing the antimicrobial activity, light sources and intensities, as well as calculation methods usually used when evaluating the antimicrobial properties of the TiO2-based products. Additionally, some strengths and weaknesses of the available methods for testing the antimicrobial activity of TiO2 photocatalyst products have been pointed out.[Projekat Ministarstva nauke Republike Srbije, br. III45008

  7. Aerobic exercise and cold pressor test induce hypoalgesia in active and inactive men and women

    DEFF Research Database (Denmark)

    Vægter, Henrik Bjarke; Handberg, Gitte; Jørgensen, Maria N.

    2015-01-01

    ). Conditioned pain modulation (CPM) was assessed by cold pressor testing. Exercise-induced hypoalgesia (EIH) was assessed after 15 minutes bicycling at a heart rate corresponding to 75% VO2max. A control session of 15 minutes quiet rest was also included. Pressure pain thresholds (PPTs) were recorded...... and after exercise, PPTs increased to the same degree in active and inactive subjects, and the CPM and EIH responses were correlated (P CPM response immediately after cold pressor test was maintained in women but not in men. CONCLUSIONS: Cold pressor stimulation and aerobic exercise caused...... comparable multisegmental increases in PPT in active and inactive men and women. The CPM and EIH responses were correlated, but they have different temporal manifestation of hypoalgesia....

  8. Impedimetric test for rapid determination of performic acid (PFA) biocidal activity toward Echerichia coli

    OpenAIRE

    Małgorzata Lasik; Renata Dobrucka; Piotr Konieczny

    2013-01-01

      Background. Performic acid has recently become available on a commercial scale for potential use in waste-water disinfection and can become an innovative biocide for various purposes in food processing. The aim of our study was: 1) to investigate the antimicrobial resistance of performic acid as high active and non toxic chemical disinfectant against Escherichi coli (hygiene indicator test  microorganism used in industrial micro- biology) and 2) to evaluate the electrical impedanc...

  9. The active straight leg raising test and mobility of the pelvic joints

    OpenAIRE

    Mens, J. M. A.; Vleeming, Andry; Snijders, Chris J.; Stam, Henk J.; Ginai, Abida Z.

    1999-01-01

    Objective signs to assess impairment in patients who are disabled by peripartum pelvic girdle pain hardly exist. The purpose of this study was to develop a clinical test to quantify and qualify disability in these patients. The study examined the relationship between impaired active straight leg raising (ASLR) and mobility of pelvic joints in patients with peripartum pelvic girdle pain, focusing on (1) the reduction of impairment of ASLR when the patient was wearing a pelvic belt, and (2) mot...

  10. Underground Test Area Activity Communication/Interface Plan, Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro, Las Vegas, NV (United States); Rehfeldt, Kenneth [Navarro, Las Vegas, NV (United States)

    2016-10-01

    The purpose of this plan is to provide guidelines for effective communication and interfacing between Underground Test Area (UGTA) Activity participants, including the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) and its contractors. This plan specifically establishes the following: • UGTA mission, vision, and core values • Roles and responsibilities for key personnel • Communication with stakeholders • Guidance in key interface areas • Communication matrix

  11. Usability testing of a monitoring and feedback tool to stimulate physical activity

    Directory of Open Access Journals (Sweden)

    van der Weegen S

    2014-03-01

    Full Text Available Sanne van der Weegen,1 Renée Verwey,1,2 Huibert J Tange,3 Marieke D Spreeuwenberg,1 Luc P de Witte1,2 1Department of Health Services Research, CAPHRI School for Public Health and Primary Care, Faculty of Health Medicine and Life Sciences, Maastricht University, the Netherlands; 2Research Centre Technology in Care, Zuyd University of Applied Sciences, Heerlen, the Netherlands; 3Department of General Practice, CAPHRI School for Public Health and Primary Care, Faculty of Health Medicine and Life Sciences, Maastricht University, the Netherlands Introduction: A monitoring and feedback tool to stimulate physical activity, consisting of an activity sensor, smartphone application (app, and website for patients and their practice nurses, has been developed: the 'It's LiFe!' tool. In this study the usability of the tool was evaluated by technology experts and end users (people with chronic obstructive pulmonary disease or type 2 diabetes, with ages from 40–70 years, to improve the user interfaces and content of the tool. Patients and methods: The study had four phases: 1 a heuristic evaluation with six technology experts; 2 a usability test in a laboratory by five patients; 3 a pilot in real life wherein 20 patients used the tool for 3 months; and 4 a final lab test by five patients. In both lab tests (phases 2 and 4 qualitative data were collected through a thinking-aloud procedure and video recordings, and quantitative data through questions about task complexity, text comprehensiveness, and readability. In addition, the post-study system usability questionnaire (PSSUQ was completed for the app and the website. In the pilot test (phase 3, all patients were interviewed three times and the Software Usability Measurement Inventory (SUMI was completed. Results: After each phase, improvements were made, mainly to the layout and text. The main improvement was a refresh button for active data synchronization between activity sensor, app, and server

  12. Influence of a prolonged fasting and mild activity on routine laboratory tests.

    Science.gov (United States)

    Šupak-Smolčić, Vesna; Antončić, Dragana; Ožanić, Doris; Vladilo, Ivana; Bilić-Zulle, Lidija

    2015-01-01

    Despite the standardization of the phlebotomy procedure, blood analysis is occasionally requested after recommended hours with the excuse that the patient is still fasting. We aimed to examine the influence of prolonged fasting and mild physical activity on routine laboratory tests. The study was conducted on 30 volunteers (27 female) median age 40y (20-59). Blood samples were taken in the morning (7:00-8:00a.m.) and early afternoon (1:00-2:00p.m.) after prolonged fasting and usual daily activities. Serum glucose (GLU), urea, creatinine, triglyceride, uric acid (UA), iron and electrolytes were analyzed on Roche cobas 6000 c501 and complete blood count on Siemens ADVIA 2120i. Statistical significance between the two measurements was tested using paired t-test or Wilcoxon test according to data distribution. Clinical significance was judged against calculated reference change values (RCV). A statistically significant decrease was found for red blood cell count, hemoglobin, hematocrit, mean corpuscular volume (MCV), GLU, urea, creatinine, triglycerides and electrolytes, whereas white blood cell count and iron were significantly increased. Judging against desirable bias derived from biological variation, a significant change was found for all the analytes except MCV, platelet count, UA and triglycerides. A clinically significant change was not found for any of the tested analytes when compared to RCV. Prolonged fasting and mild activity will not influence the medical decision for healthy subjects with normal results. Despite the present statistically significant change, the clinically significant change was not shown. However, the study did not include pathological results which have to be interpreted more carefully. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Design, Fabrication, and Testing of Active Skin Antenna with 3D Printing Array Framework

    Directory of Open Access Journals (Sweden)

    Jinzhu Zhou

    2017-01-01

    Full Text Available An active skin antenna with structural load-bearing and electromagnetic functions is usually installed in the structural surface of mobile vehicles such as aircrafts, warships, and high-speed train. This paper presents the design, fabrication, and testing of a novel active skin antenna which consists of an encapsulation shell, antenna skin, and RF and beam control circuits. The antenna skin which consists of the facesheet, honeycomb, array framework, and microstrip antenna elements was designed by using Bayesian optimization, in order to improve the design efficiency. An active skin antenna prototype with 32 microstrip antenna elements was fabricated by using a hybrid manufacturing method. In this method, 3D printing technology was applied to fabricate the array framework, and the different layers were bonded to form the final antenna skin by using traditional composite process. Some experimental testing was conducted, and the testing results validate the feasibility the proposed antenna skin structure. The proposed design and fabrication technique is suitable for the development of conformal load-bearing antenna or smart skin antenna installed in the structural surface of aircraft, warships, and armored vehicles.

  14. Evaluation of a Microbial Sensor as a Tool for Antimicrobial Activity Test of Cosmetic Preservatives.

    Science.gov (United States)

    Gomyo, Hideyuki; Ookawa, Masaki; Oshibuchi, Kota; Sugamura, Yuriko; Hosokawa, Masahito; Shionoiri, Nozomi; Maeda, Yoshiaki; Matsunaga, Tadashi; Tanaka, Tsuyoshi

    2015-01-01

    For high-throughput screening of novel cosmetic preservatives, a rapid and simple assay to evaluate the antimicrobial activities should be developed because the conventional agar dilution method is time-consuming and labor-intensive. To address this issue, we evaluated a microbial sensor as a tool for rapid antimicrobial activity testing. The sensor consists of an oxygen electrode and a filter membrane that holds the test microorganisms, Staphylococcus aureus and Candida albicans. The antimicrobial activity of the tested cosmetic preservative was evaluated by measuring the current increases corresponding to the decreases in oxygen consumption in the microbial respiration. The current increases detected by the sensor showed positive correlation to the concentrations of two commercially used preservatives, chlorphenesin and 2-phenoxyethanol. The same tendency was also observed when a model cosmetic product was used as a preservative solvent, indicating the feasibility in practical use. Furthermore, the microbial sensor and microfluidic flow-cell was assembled to achieve sequential measurements. The sensor system presented in this study could be useful in large-scale screening experiments.

  15. Activation of dorsolateral prefrontal cortex in a dual neuropsychological screening test: An fMRI approach

    Directory of Open Access Journals (Sweden)

    Tachibana Atsumichi

    2012-05-01

    Full Text Available Abstract Background The Kana Pick-out Test (KPT, which uses Kana or Japanese symbols that represent syllables, requires parallel processing of discrete (pick-out and continuous (reading dual tasks. As a dual task, the KPT is thought to test working memory and executive function, particularly in the prefrontal cortex (PFC, and is widely used in Japan as a clinical screen for dementia. Nevertheless, there has been little neurological investigation into PFC activity during this test. Methods We used functional magnetic resonance imaging (fMRI to evaluate changes in the blood oxygenation level-dependent (BOLD signal in young healthy adults during performance of a computerized KPT dual task (comprised of reading comprehension and picking out vowels and compared it to its single task components (reading or vowel pick-out alone. Results Behavioral performance of the KPT degraded compared to its single task components. Performance of the KPT markedly increased BOLD signal intensity in the PFC, and also activated sensorimotor, parietal association, and visual cortex areas. In conjunction analyses, bilateral BOLD signal in the dorsolateral PFC (Brodmann's areas 45, 46 was present only in the KPT. Conclusions Our results support the central bottleneck theory and suggest that the dorsolateral PFC is an important mediator of neural activity for both short-term storage and executive processes. Quantitative evaluation of the KPT with fMRI in healthy adults is the first step towards understanding the effects of aging or cognitive impairment on KPT performance.

  16. Activation of dorsolateral prefrontal cortex in a dual neuropsychological screening test: an fMRI approach.

    Science.gov (United States)

    Tachibana, Atsumichi; Noah, J Adam; Bronner, Shaw; Ono, Yumie; Hirano, Yoshiyuki; Niwa, Masami; Watanabe, Kazuko; Onozuka, Minoru

    2012-05-28

    The Kana Pick-out Test (KPT), which uses Kana or Japanese symbols that represent syllables, requires parallel processing of discrete (pick-out) and continuous (reading) dual tasks. As a dual task, the KPT is thought to test working memory and executive function, particularly in the prefrontal cortex (PFC), and is widely used in Japan as a clinical screen for dementia. Nevertheless, there has been little neurological investigation into PFC activity during this test. We used functional magnetic resonance imaging (fMRI) to evaluate changes in the blood oxygenation level-dependent (BOLD) signal in young healthy adults during performance of a computerized KPT dual task (comprised of reading comprehension and picking out vowels) and compared it to its single task components (reading or vowel pick-out alone). Behavioral performance of the KPT degraded compared to its single task components. Performance of the KPT markedly increased BOLD signal intensity in the PFC, and also activated sensorimotor, parietal association, and visual cortex areas. In conjunction analyses, bilateral BOLD signal in the dorsolateral PFC (Brodmann's areas 45, 46) was present only in the KPT. Our results support the central bottleneck theory and suggest that the dorsolateral PFC is an important mediator of neural activity for both short-term storage and executive processes. Quantitative evaluation of the KPT with fMRI in healthy adults is the first step towards understanding the effects of aging or cognitive impairment on KPT performance.

  17. The effect of anaerobic and aerobic tests on autonomic nervous system activity in healthy young athletes

    Directory of Open Access Journals (Sweden)

    W Ratkowski

    2010-03-01

    Full Text Available INTRODUCTION. In the evaluation of physical efficiency in professional athletes two tests are used: Wingate test (WT and incremental test for maximal oxygen uptake (IT. In the former anaerobic power is evaluated and in the latter aerobic power. The influence of these tests on autonomic nervous system (ANS activity is not fully examined. The aim of the study was to assess the influence of anaerobic and aerobic tests performed on the consecutive days, on the ANS activity in young healthy athletes. MATERIALS AND METHODS. Ten athletes aged 17 ± 1 were included in the study. The ANS parameters (baroreflex sensitivity – BRS_WBA, heart rate variability–HRV were analysed on the basis of 10-minute systolic arterial pressure and heart period (HP records during controlled breathing (0.23 Hz. BRS_WBA, HRV indices and mean HP were analysed before (examination 1 and 1 hour after WT (examination 2, 1 hour after IT (examination 3, and on the day after the tests (examination 4. RESULTS. The borderline statistically significant decrease in BRS_WBA in examination 2 in comparison to 1 was found (16.4 ± 10.5 vs 9.4 ± 3.9 ms/mmHg, p=0.059. In examination 3 in comparison to 1 the significant decrease in BRS_WBA was found (8.8 ± 6.2 ms/mmHg, p<0.05. SDNN, PNN50, RMSSD and HF were significantly lower in examination 2 comparing to 1 (p<0.05; the changes of HFnu were borderline statistically significant (p=0.059. These lower values were also noticed after examination 3 and returned to the initial values in examination 4. The mean HP showed similar changes. LF/HF increased significantly in examination 2 in comparison to 1 (p<0.05. The changes in LFnu were borderline statistically significant. CONCLUSIONS. Anaerobic and aerobic exercise tests lead to the decrease in ANS parasympathetic activity and to the increase in sympathetic one in young healthy athletes. These changes persist for at least one hour after exertion. The return to the initial values is observed the

  18. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    Science.gov (United States)

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  19. Nuclear Rocket Test Facility Decommissioning Including Controlled Explosive Demolition of a Neutron-Activated Shield Wall

    International Nuclear Information System (INIS)

    Michael Kruzic

    2007-01-01

    Located in Area 25 of the Nevada Test Site, the Test Cell A Facility was used in the 1960s for the testing of nuclear rocket engines, as part of the Nuclear Rocket Development Program. The facility was decontaminated and decommissioned (D and D) in 2005 using the Streamlined Approach For Environmental Restoration (SAFER) process, under the Federal Facilities Agreement and Consent Order (FFACO). Utilities and process piping were verified void of contents, hazardous materials were removed, concrete with removable contamination decontaminated, large sections mechanically demolished, and the remaining five-foot, five-inch thick radiologically-activated reinforced concrete shield wall demolished using open-air controlled explosive demolition (CED). CED of the shield wall was closely monitored and resulted in no radiological exposure or atmospheric release

  20. F-15B ACTIVE with thrust vectoring nozzles on test stand view from rear

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the aircraft's two new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. These nozzles give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. Ground testing of a new thrust-vectoring concept employing the nozzles took place during the first two weeks of November 1995 and went well, and flight tests began in March 1996. These tests could result in significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace.

  1. An activated energy approach for accelerated testing of the deformation of UHMWPE in artificial joints.

    Science.gov (United States)

    Galetz, Mathias Christian; Glatzel, Uwe

    2010-05-01

    The deformation behavior of ultrahigh molecular polyethylene (UHMWPE) is studied in the temperature range of 23-80 degrees C. Samples are examined in quasi-static compression, tensile and creep tests to determine the accelerated deformation of UHMWPE at elevated temperatures. The deformation mechanisms under compression load can be described by one strain rate and temperature dependent Eyring process. The activation energy and volume of that process do not change between 23 degrees C and 50 degrees C. This suggests that the deformation mechanism under compression remains stable within this temperature range. Tribological tests are conducted to transfer this activated energy approach to the deformation behavior under loading typical for artificial knee joints. While this approach does not cover the wear mechanisms close to the surface, testing at higher temperatures is shown to have a significant potential to reduce the testing time for lifetime predictions in terms of the macroscopic creep and deformation behavior of artificial joints. Copyright 2010. Published by Elsevier Ltd.

  2. Testing and evaluation of the properties of various potential materials for immobilizing high activity waste

    International Nuclear Information System (INIS)

    Malow, G.; Beran, V.; Lutze, W.

    1980-01-01

    Second joint annual report of the work performed on the testing and evaluation of materials for immobilizing high activity waste under Community contracts. At Marcoule, active block samples containing HAW from the Marcoule reprocessing plant were cast to the specification of five of the six original reference samples and leach tested at ambient temperature. Phosphate glass -bead samples produced by the Gelsenberg/DWK PAMELA process- were included in the test programme at HMI-Berlin and UKAEA Harwell. Leaching tests of inactive samples with leachants of various pH-values, with ionized water and with natural water compositions representative of certain repository conditions (salt, clay and granite) were added to the Harwell programme. The studies of radiation and thermal effects and the investigation of devitrification phenomena, started in 1977, continued, as samples reached annealing times of 2400 h and doses 4 x 10 17 dpg. The results achieved have so far confirmed most of the favourable preliminary assessments of glass based solidification products. At this stage the programme aims primarily at the understanding of physical and chemical phenomena rather that at verification under realistic waste storage and disposal conditions

  3. Promoting physical activity: development and testing of self-determination theory-based interventions

    Science.gov (United States)

    2012-01-01

    A growing number of studies have pulled from Deci and Ryan's Self-Determination Theory to design interventions targeting health behavior change. More recently, researchers have begun using SDT to promote the adoption and maintenance of an active lifestyle. In this review, we aim to highlight how researchers and practitioners can draw from the SDT framework to develop, implement, and evaluate intervention efforts centered on increasing physical activity levels in different contexts and different populations. In the present paper, the rationale for using SDT to foster physical activity engagement is briefly reviewed before particular attention is given to three recent randomized controlled trials, the Canadian Physical Activity Counseling (PAC) Trial, the Empower trial from the UK, and the Portuguese PESO (Promotion of Health and Exercise in Obesity) trial, each of which focused on promoting physical activity behavior. The SDT-based intervention components, procedures, and participants are highlighted, and the key findings that have emanated from these three trials are presented. Lastly, we outline some of the limitations of the work conducted to date in this area and we acknowledge the challenges that arise when attempting to design, deliver, and test SDT-grounded interventions in the context of physical activity promotion. PMID:22385751

  4. Instilling positive beliefs about disabilities: pilot testing a novel experiential learning activity for rehabilitation students.

    Science.gov (United States)

    Silverman, Arielle M; Pitonyak, Jennifer S; Nelson, Ian K; Matsuda, Patricia N; Kartin, Deborah; Molton, Ivan R

    2018-05-01

    To develop and test a novel impairment simulation activity to teach beginning rehabilitation students how people adapt to physical impairments. Masters of Occupational Therapy students (n = 14) and Doctor of Physical Therapy students (n = 18) completed the study during the first month of their program. Students were randomized to the experimental or control learning activity. Experimental students learned to perform simple tasks while simulating paraplegia and hemiplegia. Control students viewed videos of others completing tasks with these impairments. Before and after the learning activities, all students estimated average self-perceived health, life satisfaction, and depression ratings among people with paraplegia and hemiplegia. Experimental students increased their estimates of self-perceived health, and decreased their estimates of depression rates, among people with paraplegia and hemiplegia after the learning activity. The control activity had no effect on these estimates. Impairment simulation can be an effective way to teach rehabilitation students about the adaptations that people make to physical impairments. Positive impairment simulations should allow students to experience success in completing activities of daily living with impairments. Impairment simulation is complementary to other pedagogical methods, such as simulated clinical encounters using standardized patients. Implication of Rehabilitation It is important for rehabilitation students to learn how people live well with disabilities. Impairment simulations can improve students' assessments of quality of life with disabilities. To be beneficial, impairment simulations must include guided exposure to effective methods for completing daily tasks with disabilities.

  5. Activation calculation and radiation analysis for China Fusion Engineering Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhi, E-mail: zchen@ustc.edu.cn; Qiao, Shiji; Jiang, Shuai; Xu, X. George

    2016-11-01

    Highlights: • Activation calculation was performed using FLUKA for the main components of CFETR. • Radionuclides and radioactive wastes were assessed for CFETR. • The Waste Disposal Ratings (WDR) were assessed for CFETR. - Abstract: The activation calculation and analysis for the China Fusion Engineering Test Reactor (CFETR) will play an important role in its system design, maintenance, inspection and assessment of nuclear waste. Using the multi-particle transport code FLUKA and its associated data library, we calculated the radioactivity, specific activity, waste disposal rating from activation products, nuclides in the tritium breeding blanket, shielding layer, vacuum vessel and toroidal field coil (TFC) of CFETR. This paper presents the calculation results including neutron flux, activation products and waste disposal rating after one-year full operation of the CFETR. The findings show that, under the assumption of one-year operation at the 200 MW fusion power, the total radioactivity inventory will be 1.05 × 10{sup 19} Bq at shutdown and 1.03 × 10{sup 17} Bq after ten years. The primary residual nuclide is found to be {sup 55}Fe in ten years after the shutdown. The waste disposal rating (WDR) values are very low (<<1), according to Class C limits, CFETR materials are qualified for shallow land burial. It is shown that CFETR has no serious activation safety issue.

  6. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  7. Feasibility study of a neutron activation system for EU test blanket systems

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Kuo, E-mail: kuo.tian@kit.edu [Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Calderoni, Pattrick [Fusion for Energy(F4E), Barcelona (Spain); Ghidersa, Bradut-Eugen; Klix, Axel [Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany)

    2016-11-01

    Highlights: • This paper summarizes the technical baseline and preliminary design of EU TBM Neutron Activation System, briefly describes the key components, and outlines the major integration challenges. - Abstract: The Neutron Activation System (NAS) for the EU Helium Cooled Lithium Lead (HCLL) and Helium Cooled Pebble Bed (HCPB) Test Blanket Systems (TBSs) is an instrument that is proposed to determine the absolute neutron fluence and absolute neutron flux with information on the neutron spectrum in selected positions of the corresponding Test Blanket Modules (TBMs). In the NAS activation probes are exposed to the ITER neutron flux for periods ranging from several tens of seconds up to a full plasma pulse length, and the induced gamma activities are subsequently measured. The NAS is composed of a pneumatic transfer system and a counting station. The pneumatic transfer system includes irradiation ends in TBMs, transfer pipes, return gas pipes, a transfer station with a distributor (carousel), and a pressurized gas driving system, while the counting station consists of gamma ray detectors, signal processing electronic devices, and data analyzing software for neutron source strength evaluation. In this paper, a brief description on the proposed TBM NAS as well as the key components is presented, and the integration challenges of TBM NAS are outlined.

  8. Mast cell activation test in the diagnosis of allergic disease and anaphylaxis.

    Science.gov (United States)

    Bahri, Rajia; Custovic, Adnan; Korosec, Peter; Tsoumani, Marina; Barron, Martin; Wu, Jiakai; Sayers, Rebekah; Weimann, Alf; Ruiz-Garcia, Monica; Patel, Nandinee; Robb, Abigail; Shamji, Mohamed H; Fontanella, Sara; Silar, Mira; Mills, E N Clare; Simpson, Angela; Turner, Paul J; Bulfone-Paus, Silvia

    2018-03-05

    Food allergy is an increasing public health issue and the most common cause of life-threatening anaphylactic reactions. Conventional allergy tests assess for the presence of allergen-specific IgE, significantly overestimating the rate of true clinical allergy and resulting in overdiagnosis and adverse effect on health-related quality of life. To undertake initial validation and assessment of a novel diagnostic tool, we used the mast cell activation test (MAT). Primary human blood-derived mast cells (MCs) were generated from peripheral blood precursors, sensitized with patients' sera, and then incubated with allergen. MC degranulation was assessed by means of flow cytometry and mediator release. We compared the diagnostic performance of MATs with that of existing diagnostic tools to assess in a cohort of peanut-sensitized subjects undergoing double-blind, placebo-controlled challenge. Human blood-derived MCs sensitized with sera from patients with peanut, grass pollen, and Hymenoptera (wasp venom) allergy demonstrated allergen-specific and dose-dependent degranulation, as determined based on both expression of surface activation markers (CD63 and CD107a) and functional assays (prostaglandin D 2 and β-hexosaminidase release). In this cohort of peanut-sensitized subjects, the MAT was found to have superior discrimination performance compared with other testing modalities, including component-resolved diagnostics and basophil activation tests. Using functional principle component analysis, we identified 5 clusters or patterns of reactivity in the resulting dose-response curves, which at preliminary analysis corresponded to the reaction phenotypes seen at challenge. The MAT is a robust tool that can confer superior diagnostic performance compared with existing allergy diagnostics and might be useful to explore differences in effector cell function between basophils and MCs during allergic reactions. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights

  9. Environmental Assessment: Geothermal Energy Geopressure Subprogram. Gulf Coast Well Testing Activity, Frio Formation, Texas and Louisiana

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-02-01

    This Environmental Assessment (EA) has been prepared to provide the environmental input into the Division of Geothermal Energy's decisions to expand the geothermal well testing activities to include sites in the Frio Formation of Texas and Louisiana. It is proposed that drilling rigs be leased before they are removed from sites in the formation where drilling for gas or oil exploration has been unsuccessful and that the rigs be used to complete the drilling into the geopressured zone for resource exploration. This EA addresses, on a regional basis, the expected activities, affected environment, and the possible impacts in a broad sense as they apply to the Gulf Coast well testing activity of the Geothermal Energy Geopressure Subprogram of the Department of Energy. Along the Texas and Louisiana Gulf Coast (Plate 1 and Overlay, Atlas) water at high temperatures and high pressures is trapped within Gulf basin sediments. The water is confined within or below essentially impermeable shale sequences and carries most or all of the overburden pressure. Such zones are referred to as geopressured strata. These fluids and sediments are heated to abnormally high temperatures (up to 260 C) and may provide potential reservoirs for economical production of geothermal energy. The obvious need in resource development is to assess the resource. Ongoing studies to define large-sand-volume reservoirs will ultimately define optimum sites for drilling special large diameter wells to perform large volume flow production tests. in the interim, existing well tests need to be made to help define and assess the resource.

  10. Is it better to select or to receive? Learning via active and passive hypothesis testing.

    Science.gov (United States)

    Markant, Douglas B; Gureckis, Todd M

    2014-02-01

    People can test hypotheses through either selection or reception. In a selection task, the learner actively chooses observations to test his or her beliefs, whereas in reception tasks data are passively encountered. People routinely use both forms of testing in everyday life, but the critical psychological differences between selection and reception learning remain poorly understood. One hypothesis is that selection learning improves learning performance by enhancing generic cognitive processes related to motivation, attention, and engagement. Alternatively, we suggest that differences between these 2 learning modes derives from a hypothesis-dependent sampling bias that is introduced when a person collects data to test his or her own individual hypothesis. Drawing on influential models of sequential hypothesis-testing behavior, we show that such a bias (a) can lead to the collection of data that facilitates learning compared with reception learning and (b) can be more effective than observing the selections of another person. We then report a novel experiment based on a popular category learning paradigm that compares reception and selection learning. We additionally compare selection learners to a set of "yoked" participants who viewed the exact same sequence of observations under reception conditions. The results revealed systematic differences in performance that depended on the learner's role in collecting information and the abstract structure of the problem.

  11. Activation and afterheat analyses for the HCPB test blanket module in ITER

    International Nuclear Information System (INIS)

    Pereslavtsev, P.; Fischer, U.

    2008-01-01

    To provide a sound data basis for the safety analyses of the HCPB TBM system in ITER, the afterheat and activity inventories were assessed making use of a code system that allows performing 3D activation calculations by linking the Monte Carlo transport code MCNP and the fusion inventory code FISPACT through an appropriate interface. A suitable MCNP model of a 20 deg. ITER torus sector with an integrated TBM of the HCPB PI (plant integration) type in the horizontal test blanket port was developed and adapted to the requirements for coupled 3D neutron transport and activation calculations. Two different irradiation scenarios were considered in the coupled 3D neutron transport and activation calculations. The first one is representative for the TBM irradiation in ITER with a total of 9000 neutron pulses over a 3 (calendar) years period. The second (conservative) irradiation scenario assumes an extended irradiation time over the full anticipated lifetime of ITER. The radioactivity inventories, the afterheat and the contact gamma dose were calculated as function of the decay time. Data were processed for the total activity, afterheat and contact dose rates of the TBM, its constituting components and materials

  12. Basic Characteristics of Human Erroneous Actions during Test and Maintenance Activities Leading to Unplanned Reactor Trips

    International Nuclear Information System (INIS)

    Kim, Jae Whan; Park, Jin Kyun

    2010-01-01

    Test and maintenance (T and M) activities of nuclear power plants are essential for sustaining the safety of a power plant and maintaining the reliability of plant systems and components. However, the potential of human errors during T and M activities has also the potential to induce unplanned reactor trips or power derate or making safety-related systems unavailable. According to the major incident/accident reports of nuclear power plants in Korea, contribution of human errors takes up about 20% of the total events. The previous study presents that most of human-related unplanned reactor trip events during normal power operation are associated with T and M activities (63%), which are comprised of plant maintenance activities such as a 'periodic preventive maintenance (PPM)', a 'planned maintenance (PM)' and a 'corrective maintenance (CM)'. This means that T and M activities should be a major subject for reducing the frequency of human-related unplanned reactor trips. This paper aims to introduce basic characteristics of human erroneous actions involved in the test and maintenance-induced unplanned reactor trip events that have occurred between 1986 and 2006 in Korean nuclear power plants. The basic characteristics are described by dividing human erroneous actions into planning-based errors and execution-based errors. For the events associated with planning failures, they are, firstly, classified according to existence of the work procedure and then described for what aspects of the procedure or work plan have deficiency or problem. On the other hand, for the events associated with execution failures, they are described from the aspect of external error modes

  13. An experimental test of the fluctuation relation in an active camphor boat system

    Science.gov (United States)

    Paroor, H. M.; Nambiar, N.; Bandi, M. M.

    The Gallavotti-Cohen fluctuation relation (FR) posits a specific symmetry between positive and negative fluctuations in entropy production, or a related quantity (e.g power) for systems in non-equilibrium stationary state. Successful tests in a variety of systems suggest the FR may be more generally applicable than the conditions under which it was originally derived. Systems where the FR fails are therefore valuable for the insight they provide into the FR's general success. It has recently been suggested that ``active matter'' should not satisfy the fluctuation-dissipation theorem or FR. We experimentally test this possibility in a system of active camphor boats, self-propelled by surface tension gradients at air-water interfaces. The boats interact via short-range capillary attraction which competes with long-range surface tension mediated repulsion. Tuning interaction strength with number density, we test the FR through the statistics of power as one goes from a free non-interacting camphor boat, through a few weakly interacting boats to several, strongly interacting boats. We present preliminary results of our experiments and data analysis.

  14. Antidepressant-like activity of Sonchus oleraceus in mouse models of immobility tests.

    Science.gov (United States)

    Vilela, Fabiana Cardoso; Padilha, Marina de Mesquita; Alves-da-Silva, Geraldo; Soncini, Roseli; Giusti-Paiva, Alexandre

    2010-02-01

    The aim of the present work is to evaluate the putative antidepressant-like effects of hydroethanolic and dichloromethanic extracts from the aerial parts of Sonchus oleraceus (Family Asteraceae) on the performance of male mice in the forced swimming test (FST) and tail suspension test (TST) models predictive of depression. The hydroethanolic and dichloromethanic extracts, both in doses of 30, 100, and 300 mg/kg, were orally administered 1 hour before carrying out the FST or the TST. The immobility time in both the FST and the TST was significantly reduced by acute oral treatment with the extracts (dose range, 100-300 mg/kg), without accompanying changes in ambulation, as assessed in an open-field test. This excluded the possibility that the effect of the extracts is due to an activation of locomotion. The efficacy of the extracts was found to be comparable to that of amitriptyline (10 mg/kg, p.o.). The present study provides evidence for an antidepressant-like effect of the active principle(s) present in the extracts of S. oleraceus in mice. Therefore, a standardized S. oleraceus extract or its purified constituents could be of potential interest for the treatment of depressive disorders.

  15. Characterization of biological activity of cigarette smoke using in vitro tests

    International Nuclear Information System (INIS)

    Brooks, A.L.; Chen, B.T.; Mauderly, J.L.

    1988-01-01

    Studies were conducted to characterize the influence of exposure mode (whole-body continuous, nose only intermittent, nose-only continuous) on biological activity of cigarette smoke condensates. The mutagenic potency of the extracts was determined using Salmonella typhimurium tester strain TA-98 with and without the addition of S-9. The cytotoxicity of the cigarette smoke with and without the addition of S-9 was also determined using Chinese hamster ovary cells (CHO). Mutagenic activity was observed in the Ames test only after the addition of S-9. The optimum mutagenic activity was observed following addition of between 3 and 6% S-9. The average mutagenic potency, when cells were tested at the optimum level of S-9, was 1.5 revertants/mg extract. Cell killing by cigarette smoke extracts was the same for extracts derived from all three exposure modes. There was about 20% cell killing at concentrations of 300 mg extract/mL culture media. No differences were observed in either mutagenic or cytotoxic potency among the smoke extracts produced under different exposure conditions. (author)

  16. Pilot Study on the Genetic Background of an Active Matrix Metalloproteinase-8 Test in Finnish Adolescents.

    Science.gov (United States)

    Heikkinen, Anna Maria; Raivisto, Teija; Kettunen, Kaisa; Kovanen, Leena; Haukka, Jari; Pakbaznejad Esmaeili, Elmira; Elg, Jessica; Gieselmann, Dirk-Rolf; Rathnayake, Nilminie; Ruokonen, Hellevi; Tervahartiala, Taina; Sorsa, Timo

    2017-05-01

    In periodontitis, genetics and smoking play important roles in host immune system response. The aim of this study is to determine whether the genetic background of initial periodontitis and caries could be detected using an active matrix metalloproteinase (aMMP)-8 chairside test in Finnish adolescents. Forty-seven participants gave approval for analysis of both oral fluid collection and DNA. An aMMP-8 chairside test was performed on participants (adolescents aged 15 to 17 years), and full-mouth clinical parameters of oral health were assessed including periodontal, oral mucosal, and caries status in Eastern Finland from 2014 to 2015. DNA was extracted from oral fluid samples and genotyped for 71 polymorphisms in 29 candidate genes for periodontitis. Results were analyzed using a logistic regression model. P values were corrected for multiple testing using false discovery rate (<0.05). aMMP-8 chairside test positivity and three or more ≥4 mm pockets were associated with vitamin D receptor (VDR) (rs2228570, P = 0.002, q = 0.04) and MMP3 (rs520540, rs639752, rs679620, P = 0.0009, 0.003, 0.003, q = 0.04, respectively). None of the other single-nucleotide polymorphisms studied showed a significant association with the aMMP-8 chairside test and at least one caries lesion positivity. Genetic polymorphisms of MMP3 and VDR are linked to initial periodontitis in Finnish adolescents, and the aMMP-8 chairside test can eventually detect initial periodontitis in young patients with predisposing genetic background.

  17. Active thermal tracer testing in a shallow aquifer of the Thur valley, Switzerland

    Science.gov (United States)

    Schweingruber, Mischa; Somogyvári, Márk; Bayer, Peter

    2015-04-01

    Tracer tests are one of the standard methods for investigating groundwater processes. Among the range of different test variants, using heat as a tracer has gained substantial interest during the last decade. Temperature measurements have become essential ingredients for example for characterization of river-aquifer interactions and in the field of geothermics. Much less attention than on natural temperature signals has been devoted to induced synthetic temperature signals, even though it is well known that temperature is an easy to measure, invisible but sensitive system property. Design, application and inversion of such active thermal tracer tests represent one focus of our work. We build up on the experience from related field experiments, where heated water was injected and the propagation of the generated thermal anomaly was monitored. In this presentation, we show the results from first field-testing in an alluvial aquifer at the Widen site in the Thur valley in Switzerland. The thermal evolution of groundwater was monitored in summer 2014 during and after several days of heated water injection. By this test, we want to derive insights into the prevailing hydraulic heterogeneity of the shallow aquifer at the site. The results are used for calibration of a two dimensional hydrogeological numerical model. With the calibrated hydraulic conductivity field, the experiment is simulated and the transient evolution of the heat plume is visualized. Hydraulic heterogeneity is identified as one main factor for lateral spreading of the heat plume. The most important result of the experiment is that the significance of the ambient flow field is very high and even with high pumping rates to establish forced gradient conditions its effect cannot be overridden. During the test, precious technical experience was gained, which will be beneficial for subsequent heat tracer applications. For example, the challenge of maintaining a constant injection rate and temperature could

  18. Inhibition of enzyme activity by nanomaterials: potential mechanisms and implications for nanotoxicity testing.

    Science.gov (United States)

    Maccormack, Tyson J; Clark, Rhett J; Dang, Michael K M; Ma, Guibin; Kelly, Joel A; Veinot, Jonathan G C; Goss, Greg G

    2012-08-01

    The objective of this study was to investigate whether nanoparticle-exposure affects enzyme function and to determine the mechanisms responsible. Silicon, Au, and CdSe nanoparticles were synthesized in house and their physicochemical properties were characterized. The activity of purified lactate dehydrogenase (LDH) was inhibited or abolished by all nanoparticles tested. Inhibition was dependent upon particle core and surface-functional group composition. Inhibition of LDH was absent in crude tissue homogenates, in the presence of albumin, and at the isoelectric point of the protein, indicating that nanoparticles bind non-specifically to abundant proteins via a charge interaction. Circular dichroism spectroscopy suggests that the structure of LDH may be altered by nanoparticles in a manner different from that of bulk controls. We present new data on the specific physicochemical properties of nanoparticles that may lead to bioactivity and highlight a number of potentially serious problems with common nanotoxicity testing methods.

  19. [Effect of psychotropic drugs on activity of anticonvulsants in maximal electroshock test].

    Science.gov (United States)

    Alikina, N A; Tregubov, A L; Kotegov, V P

    2010-08-01

    The effect ofpsychotropic drugs on the pharmacological properties of anticonvulsants was studied on white mice under maximal electroshock (ME) test conditions. Changes in the anticonvulsant effect of phenobarbital, diphenin, carbamazepine, hexamidine were traced upon their joint administration with psychotropic drugs, including piracetam, aminalon, amitriptyline, imizine, levomepromazine, and lithium oxybutyrate. An important result of research is the fact, that in no one of combinations the basic pharmacological effect of anticonvulsants was decreased. Based on the results of experiments, the most rational combinations of anticonvulsants with psychotropic preparations were revealed as manifested in the ME test. As criterion of rational combination was the increase in the activity of anticonvulsants and reduction of their toxicity in combination or at least invariance of this parameter. Rational combinations include (i) phenobarbital with piracetam, amitriptyline, levomepromazine, and lithium oxybutyrate; (ii) carbamazepine with piracetam; and (iii) hexamidine with amitriptyline, levomepromazine and imizine.

  20. ASTM and VAMAS activities in titanium matrix composites test methods development

    Science.gov (United States)

    Johnson, W. S.; Harmon, D. M.; Bartolotta, P. A.; Russ, S. M.

    1994-01-01

    Titanium matrix composites (TMC's) are being considered for a number of aerospace applications ranging from high performance engine components to airframe structures in areas that require high stiffness to weight ratios at temperatures up to 400 C. TMC's exhibit unique mechanical behavior due to fiber-matrix interface failures, matrix cracks bridged by fibers, thermo-viscoplastic behavior of the matrix at elevated temperatures, and the development of significant thermal residual stresses in the composite due to fabrication. Standard testing methodology must be developed to reflect the uniqueness of this type of material systems. The purpose of this paper is to review the current activities in ASTM and Versailles Project on Advanced Materials and Standards (VAMAS) that are directed toward the development of standard test methodology for titanium matrix composites.

  1. F-15B ACTIVE with thrust vectoring nozzles on test stand

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the thrust stand being used for ground testing of a new thrust-vectoring concept involving two new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. These nozzles give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. These tests could lead to significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace.

  2. F-15B ACTIVE with thrust vectoring nozzles on test stand at sunrise

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the aircraft on a test stand at sunrise. Not shown in this photograph are the aircraft's two new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. These nozzles give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. These tests could result in significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace. The aircraft was originally built as an F-15B (Serial #71-0290).

  3. Tigecycline activity tested against 26,474 bloodstream infection isolates: a collection from 6 continents.

    Science.gov (United States)

    Sader, Helio S; Jones, Ronald N; Stilwell, Matthew G; Dowzicky, Michael J; Fritsche, Thomas R

    2005-07-01

    The activity of tigecycline (formerly GAR936), a novel glycylcycline, was tested against recent bloodstream infection (BSI) pathogen isolates from 6 continents. Frequency of clinical occurrence of these pathogens was determined and their antibiograms assessed using reference broth microdilution methods. A total of 26474 strains were tested for tigecycline susceptibility according to the Clinical and Laboratory Standards Institute (formerly the National Committee for Clinical Laboratory Standards) by the M7-A6 guidelines with interpretations from M100-S15 and the package insert. The rank order of pathogens was Staphylococcus aureus (33.1%), Escherichia coli (14.0%), coagulase-negative staphylococci (13.5%), Enterococcus spp. (12.3%), Klebsiella spp. (5.7%), Pseudomonas aeruginosa (4.2%), Enterobacter spp. (3.0%), beta-hemolytic streptococci (2.9%), Streptococcus pneumoniae (2.3%), and viridans group streptococci (1.4%). Tigecycline exhibited a broader spectrum of activity against BSI isolates when compared to ciprofloxacin, tetracycline, aminoglycosides, and many beta-lactams (imipenem). Tigecycline was highly active against most pathogens tested, including staphylococci (MIC(90), 0.5 microg/mL), enterococci (MIC90, 0.25 microg/mL), streptococci (MIC(90), < or =0.12 microg/mL), Escherichia coli (MIC90, 0.25 microg/mL), Klebsiella spp. (MIC90, 1 mmicrog/mL), and Enterobacter spp. (MIC(90), 2 mmicrog/mL), but showed limited inhibition of Pseudomonas aeruginosa (MIC90, 16 microg/mL) and indole-positive or indole-negative Proteae (MIC90, 4-8 microg/mL). In summary, tigecycline exhibited a wide spectrum of antimicrobial potency versus BSI isolates collected worldwide. Serious infections in nosocomial environments should benefit from tigecycline use among the investigational phase 3 agents focused toward resistant strains.

  4. Thermal fatigue tests with actively cooled divertor mock-ups for ITER

    International Nuclear Information System (INIS)

    Roedig, M.; Duwe, R.; Linke, J.; Schuster, A.; Wiechers, B.; Ibbott, C.; Jacobson, D.; Le Marois, G.; Lind, A.; Lorenzetto, P.; Vieider, G.; Peacock, A.; Ploechl, L.; Severi, Y.; Visca, E.

    1998-01-01

    Mock-ups for high heat flux components with beryllium and CFC armour materials have been tested by means of the electron beam facility JUDITH. The experiments concerned screening tests to evaluate heat removal efficiency and thermal fatigue tests. CFC monoblocks attached to DS-Cu (Glidcop Al25) and CuCrZr tubes by active metal casting and Ti brazing showed the best thermal fatigue behaviour. They survived more than 1000 cycles at heat loads up to 25 MW m -2 without any indication of failure. Operational limits are given only by the surface temperature on the CFC tiles. Most of the beryllium mock-ups were of the flat tile type. Joining techniques were brazing, hot isostatic pressing (HIP) and diffusion bonding. HIPed and diffusion bonded Be/Cu modules have not yet reached the standards for application in high heat flux components. The limit of this production method is reached for heat loads of approximately 5 MW m -2 . Brazing with and without silver seems to be a more robust solution. A flat tile mock-up with CuMnSnCe braze was loaded at 5.4 MW m -2 for 1000 cycles without damage The first test with a beryllium monoblock joined to a CuCrZr tube by means of Incusil brazing shows promising results; it survived 1000 cycles at 4.5 MW m -2 without failure. (orig.)

  5. Detailed leak detection test plan and schedule for the Oak Ridge National Laboratory LLLW active pipelines

    International Nuclear Information System (INIS)

    Douglas, D.G.; Starr, J.W.; Juliano, T.M.; Maresca, J.W. Jr.

    1993-09-01

    This document provides a detailed leak detection test plan and schedule for leak testing many of the pipelines that comprise the active portion of the liquid low-level waste (LLLW) system at the Oak Ridge National Laboratory (ORNL). This plan was prepared in response to the requirements of the Federal Facility Agreement (FFA) between the US Department of Energy (DOE) and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC). The LLLW system is an interconnected complex of tanks and pipelines. The FFA distinguishes four categories of tank and pipeline systems within this complex: new systems (Category A), doubly contained systems (Category B), singly contained systems (Category C), and inactive systems (Category D). The FFA specifically requires leak testing of the Category C systems. This plan and schedule addresses leak testing of the Category C pipelines and those doubly contained pipelines that do not fully meet the requirements for secondary containment as listed in the FFA

  6. Development and testing of an electrochemical separation process for cutting activated steel components

    International Nuclear Information System (INIS)

    Stang, W.; Fischer, A.; Pott, P.

    1991-01-01

    Electrochemical decontamination has a great importance for the decommissioning works at KRB A. By this method the metal surface is slightly removed due to a galvanic process in an electrolytic solution. Using the same principle it is also possible to remove material locally (ECM-technique). Many advantages of this method indicated that it could be used for cutting activated steel during decommissioning of nuclear power plants. In the frame of this research contract, experiments with non-active material from a reactor pressure vessel were investigated. The essential results demonstrated - which procedures and cathodes are suitable for high cutting velocities - and which amount of sludge (waste) will be produced in the electrolyte. The research programme has been carried out in cooperation with AEG-Elotherm, Remscheid. The test facility, the execution as well as the evaluation of the experiments were made by AEG-Elotherm

  7. Testing FLUKA on neutron activation of Si and Ge at nuclear research reactor using gamma spectroscopy

    Science.gov (United States)

    Bazo, J.; Rojas, J. M.; Best, S.; Bruna, R.; Endress, E.; Mendoza, P.; Poma, V.; Gago, A. M.

    2018-03-01

    Samples of two characteristic semiconductor sensor materials, silicon and germanium, have been irradiated with neutrons produced at the RP-10 Nuclear Research Reactor at 4.5 MW. Their radionuclides photon spectra have been measured with high resolution gamma spectroscopy, quantifying four radioisotopes (28Al, 29Al for Si and 75Ge and 77Ge for Ge). We have compared the radionuclides production and their emission spectrum data with Monte Carlo simulation results from FLUKA. Thus we have tested FLUKA's low energy neutron library (ENDF/B-VIIR) and decay photon scoring with respect to the activation of these semiconductors. We conclude that FLUKA is capable of predicting relative photon peak amplitudes, with gamma intensities greater than 1%, of produced radionuclides with an average uncertainty of 13%. This work allows us to estimate the corresponding systematic error on neutron activation simulation studies of these sensor materials.

  8. Performance testing of Tesla NNG 601 activity meter in nuclear medicine department

    International Nuclear Information System (INIS)

    Husak, V.; Kleinbauer, K.

    1980-01-01

    The results are presented of testing activity meter Tesla NNG 601 the production of which began in Czechoslovakia in 1978. The meter is provided with a shielded well-type ionization chamber, the well 42 mm in diameter and 140 mm deep. The parameters of the instrument linearity, volume dependence, accuracy and stability, correctness of calibration were compared with those of other instruments (Searle Analytic, Picker and Capinted). The volume dependence of the Czechoslovak NNG 601 instrument is higher than that in the other instruments, other parameters are the same of better

  9. Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine

    Energy Technology Data Exchange (ETDEWEB)

    Mule, S.J.; Lomax, P.; Gross, S.J.

    1988-05-01

    Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation.

  10. Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine

    International Nuclear Information System (INIS)

    Mule, S.J.; Lomax, P.; Gross, S.J.

    1988-01-01

    Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation

  11. The validation of waste assay systems during active test at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Tamura, Takayuki; Miura, Yasushi; Iwamoto, Tomonori

    2007-01-01

    In order to implement accurate material accountancy at Rokkasho Reprocessing Plant (RRP) as a large scale reprocessing plant, it is necessary to introduce accurate measurement systems not only for mainstream material, but also appropriate measurement systems for solid waste materials. In this sense, the generated wastes by the active test operation have been measured with the Non-Destructive Assay Systems, such as Rokkasho Hulls Measurement System (RHMS) and Waste Crate Assay System (WCAS) for accountancy. This paper describes the experience of the NDA operation and the evaluation results for accountancy. (author)

  12. Performance of IPEN/CNEN-SP Neutron Activation Analysis Laboratory for microelement determinations in proficiency testing

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Saiki, Mitiko; Souza, Gilberto B. de; Nogueira, Ana Rita A.

    2009-01-01

    The performance of Neutron Activation Laboratory, IPEN - CNEN/SP, was evaluated for the Ca, Fe, K, Mn, Na and Zn determinations in animal feed samples for ruminants through a proficiency test (PT) program. This PT program is organized by EMBRAPA Cattle Southeast to evaluate laboratories that analyze animal feed samples. Considering the fractions of satisfactory z-scores (%) of evaluated analytes to determine the laboratories performance, the general performance indicator obtained by IPEN - CNEN/SP ranged from 90 to 95% of the satisfactory results during the period of participation in the evaluation, four years. (author)

  13. A randomized controlled trial testing a social network intervention to promote physical activity among adolescents.

    Science.gov (United States)

    van Woudenberg, Thabo J; Bevelander, Kirsten E; Burk, William J; Smit, Crystal R; Buijs, Laura; Buijzen, Moniek

    2018-04-23

    The current study examined the effectiveness of a social network intervention to promote physical activity among adolescents. Social network interventions utilize peer influence to change behavior by identifying the most influential individuals within social networks (i.e., influence agents), and training them to promote the target behavior. A total of 190 adolescents (46.32% boys; M age = 12.17, age range: 11-14 years) were randomly allocated to either the intervention or control condition. In the intervention condition, the most influential adolescents (based on peer nominations of classmates) in each classroom were trained to promote physical activity among their classmates. Participants received a research smartphone to complete questionnaires and an accelerometer to measure physical activity (steps per day) at baseline, and during the intervention one month later. A multilevel model tested the effectiveness of the intervention, controlling for clustering of data within participants and days. No intervention effect was observed, b = .04, SE = .10, p = .66. This was one of the first studies to test whether physical activity in adolescents could be promoted via influence agents, and the first social network intervention to use smartphones to do so. Important lessons and implications are discussed concerning the selection criterion of the influence agents, the use of smartphones in social network intervention, and the rigorous analyses used to control for confounding factors. Dutch Trial Registry (NTR): NTR6173 . Registered 5 October 2016 Study procedures were approved by the Ethics Committee of the Radboud University (ECSW2014-100614-222).

  14. A pilot test of the Latin active hip hop intervention to increase physical activity among low-income Mexican-American adolescents.

    Science.gov (United States)

    Romero, Andrea J

    2012-01-01

    The primary purpose of the current study was to develop, implement, and evaluate a hip hop dance intervention, Latin Active, among low-income Mexican-American adolescents. Mexican-descent adolescents tend to have disproportionate rates of low physical activity, overweight status, and obesity. A 5-week intervention design with pretest and post-test self-report measures. Charter middle school (grades 6-9) health/science classes in a low-income neighborhood were the setting for the Latin Active intervention. Overall, 81 participants were recruited; 73 (n  =  41, female; n  =  32, male) provided active parental consent to complete pretest/post-test surveys. Intervention . The Latin Active program included 10 interactive 50-minute lessons that were delivered twice a week during science/health classes. The curriculum was created on the basis of Social Cognitive Theory, Critical Hip Hop Pedagogy, and feedback from key stakeholders. The lessons focused on increasing physical activity as well as neighborhood barriers. The self-report pretest (n  =  73) and post-test (n  =  56) surveys included measures for frequency of vigorous physical activity, self-efficacy, and neighborhood barriers. Analysis . Paired-sample t-test analyses were conducted to assess mean differences from pretest to post-test results for intervention outcomes by gender. The Latin Active program (with 77% retention at post-test) significantly increased vigorous physical activity and dance (p hip hop physical activity program, Latin Active demonstrated preliminary efficacy to increase girl's vigorous physical activity and boy's perception of neighborhood barriers to physical activity. Future research will need to use a randomized, controlled design and investigate the effect of the program on measures of body mass index.

  15. 13C mixed triglyceride breath test: a noninvasive method to assess lipase activity in children.

    Science.gov (United States)

    van Dijk-van Aalst, K; Van Den Driessche, M; van Der Schoor, S; Schiffelers, S; van't Westeinde, T; Ghoos, Y; Veereman-Wauters, G

    2001-05-01

    Results from the 13C mixed triglyceride (MTG) breath test correlate with duodenal lipase activity in adults. This noninvasive test is a potential screening and diagnostic tool for children with fat malabsorption. The aim of this study was to adapt the methodology of the MTG breath test to study test meals and sampling methods and to define normal values for healthy children of all age groups; premature and full-term infants have similar pancreatic lipase deficiencies. After parental consent was obtained, 12 premature infants ( 2 kg), 12 full-term infants (1-6 months old), 20 children (3-10 years old), and 20 teenagers (11-17 years old) were tested. All children were thriving well, had no gastrointestinal or respiratory problems, and had not received any medication that contained natural 13C. For the premature and full-term infants, a formula was prepared that had a low and stable natural 13C content mixed with 100 mg 13C-labeled MTG (1,3-distearyl, 2-[13C-carboxyl] octanoyl glycerol) and 1 g polyethylene-glycol 3350. The best accepted test meal for children over 3 years old was a slice of white bread with 5 g butter and 15 g chocolate paste, mixed with 250 mg 13C-labeled MTG, and a glass of 100 mL whole-fat milk. Children over 3 years old were able to blow through a straw in a vacutainer for collecting the breath samples. In children under 3 years old, expired air was collected by aspirating breath via a nasal prong. Carbon dioxide production was calculated according to weight, age, and sex. For healthy pediatric control participants, the mean values for cumulative excretion of 13CO2 as a percentage of the administered dose after 6 hours were 23.9 +/- 5.2% in premature infants, 31.9 +/- 7.7% in full-term infants, 32.5 +/- 5.3% in children, and 28.0 +/- 5.4% in teenagers. The mean value for healthy adults is 35.6% with a lower reference limit of 22.8%. Age-specific test meals and breath-sampling techniques for the MTG breath test were defined. The mean values for

  16. Results of full scale dry injection tests at MSW-incinerators using a new active absorbent

    International Nuclear Information System (INIS)

    Felsvang, K.S.; Helvind, O.

    1991-01-01

    Worldwide incineration of municipal solid waste (MSW) has been utilized to reduce the volume of waste to be disposed of. Increasing environmental concerns over the potential air pollution impacts have led to emission limits for pollutants such as HCl, SO 2 , particulate, and more recently also for mercury and dioxins. For a certain size of incinerators, dry sorbent injection is the preferred technology for air pollution control. This paper describes the development of a new active sorbent, Scansorb, which is particularly suited for use in dry injection processes. The new sorbent is a lime based product with adjustable properties. Scansorb can be produced with a specific surface area of 30 to 100 m 2 /g. Pilot plant development work has shown that a considerable reduction in the absorbent quantity can be achieved when Scansorb is used instead of commercial hydrated lime. Full scale tests performed at four different MSW incinerators have confirmed the viability of the new active absorbent. The full scale tests have demonstrated that more than 50% SO 2 removal can be achieved with Scansorb at quantities much less than with commercial hydrated lime

  17. Analytical quality control of neutron activation analysis by interlaboratory comparison and proficiency test

    International Nuclear Information System (INIS)

    Kim, S. H.; Moon, J. H.; Jeong, Y. S.

    2002-01-01

    Two air filters (V-50, P-50) artificially loaded with urban dust were provided from IAEA and trace elements to study inter-laboratory comparison and proficiency test were determined using instrumental neutron activation analysis non-destructively. Standard reference material(Urban Particulate Matter, NIST SRM 1648) of National Institute of Standard and Technology was used for internal analytical quality control. About 20 elements in each loaded filter sample were determined, respectively. Our analytical data were compared with statistical results using neutron activation analysis, particle induced X-ray emission spectrometry, inductively coupled plasma mass spectroscopy, etc., which were collected from 49 laboratories of 40 countries. From the results that were statistically re-treated with reported values, Z-scores of our analytical values are within ±2. In addition, the results of proficiency test are passed and accuracy and precision of the analytical values are reliable. Consequently, it was proved that analytical quality control for the analysis of air dust samples is reasonable

  18. A novel preterm respiratory mechanics active simulator to test the performances of neonatal pulmonary ventilators

    Science.gov (United States)

    Cappa, Paolo; Sciuto, Salvatore Andrea; Silvestri, Sergio

    2002-06-01

    A patient active simulator is proposed which is capable of reproducing values of the parameters of pulmonary mechanics of healthy newborns and preterm pathological infants. The implemented prototype is able to: (a) let the operator choose the respiratory pattern, times of apnea, episodes of cough, sobs, etc., (b) continuously regulate and control the parameters characterizing the pulmonary system; and, finally, (c) reproduce the attempt of breathing of a preterm infant. Taking into account both the limitation due to the chosen application field and the preliminary autocalibration phase automatically carried out by the proposed device, accuracy and reliability on the order of 1% is estimated. The previously indicated value has to be considered satisfactory in light of the field of application and the small values of the simulated parameters. Finally, the achieved metrological characteristics allow the described neonatal simulator to be adopted as a reference device to test performances of neonatal ventilators and, more specifically, to measure the time elapsed between the occurrence of a potentially dangerous condition to the patient and the activation of the corresponding alarm of the tested ventilator.

  19. Survey of active and inactive mines for possible use as in situ test facilities

    International Nuclear Information System (INIS)

    1976-09-01

    A survey of active and inactive mines which might be useful for radioactive waste storage in situ test experiments was conducted. It was performed for Union Carbide Corporation, Nuclear Division, Office of Waste Isolation. The report covers available information gathered from literature, U.S. Bureau of Mines, the Mining Enforcement and Safety Agency, and a limited number of personal contacts with constructors or operators of facilities. This survey is preliminary in nature and the objective is to develop potential candidate facilities for in situ experiments which warrant further investigation. Included are descriptions of 244 facilities, with all the data about each one which was available within the time restraint of the study. These facility descriptions are additionally indexed by depth of mine, nature of the country rock, mineral mined, and type of entry. A total of 14 inactive mines and 34 active mines has been selected as those most worthy of further investigation for possible service as nuclear waste isolation test facilities. This investigation, being preliminary and having been performed in a very short time period, must be qualified, and the description of the qualification is presented in the body of this report. Qualifications deal primarily with the hazard of having omitted facilities and having incomplete data in some instances. Results indicate sedimentary rock mines of minerals of evaporite origin as a first ranking of preference for in situ testing, followed by other sedimentary rocks and then by mines producing minerals from any type rock where the mine is above the local water table. These are general rules and of course there can be exceptions to them

  20. Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

    Science.gov (United States)

    Sunada, Eric; Birur, Gajanana C.; Ganapathi, Gani B.; Miller, Jennifer; Berisford, Daniel; Stephan, Ryan

    2010-01-01

    NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

  1. Using tests and models to assess antidepressant-like activity in rodents

    Directory of Open Access Journals (Sweden)

    Kedzierska Ewa

    2016-06-01

    Full Text Available In today's world, depression is one of the more prevalent forms of mental illness. According to WHO, about 10%-30% of all women and 7%-15% of all men are afflicted by depression at least once in their life-times. Today, depression is assessed to be affecting 350 million people. Regarding this issue, an important challenge for current psychopharmacology is to develop new, more effective pharmacotherapy and to understand the mechanism of action of known antidepressants. Furthermore, there is the necessity to improve the effectiveness of anti-depression treatment by way of bringing about an understanding of the neurobiology of this illness. In achieving these objectives, animal models of depression can be useful. Yet, presently, all available animal models of depression rely on two principles: the actions of known antidepressants or the responses to stress. In this paper, we present an overview of the most widely used animal tests and models that are employed in assessing antidepressant-like activity in rodents. These include amphetamine potentiation, reversal of reserpine action, the forced swimming test, the tail suspension test, learned helplessness, chronic mild stress and social defeat stress. Moreover, the advantages and major drawbacks of each model are also discussed.

  2. Hot-Film and Hot-Wire Anemometry for a Boundary Layer Active Flow Control Test

    Science.gov (United States)

    Lenahan, Keven C.; Schatzman, David M.; Wilson, Jacob Samuel

    2013-01-01

    Unsteady active flow control (AFC) has been used experimentally for many years to minimize bluff-body drag. This technology could significantly improve performance of rotorcraft by cleaning up flow separation. It is important, then, that new actuator technologies be studied for application to future vehicles. A boundary layer wind tunnel was constructed with a 1ft-x-3ft test section and unsteady measurement instrumentation to study how AFC manipulates the boundary layer to overcome adverse pressure gradients and flow separation. This unsteady flow control research requires unsteady measurement methods. In order to measure the boundary layer characteristics, both hot-wire and hot-film Constant Temperature Anemometry is used. A hot-wire probe is mounted in the flow to measure velocity while a hot-film array lays on the test surface to measure skin friction. Hot-film sensors are connected to an anemometer, a Wheatstone bridge circuit with an output that corresponds to the dynamic flow response. From this output, the time varying flow field, turbulence, and flow reversal can be characterized. Tuning the anemometers requires a fan test on the hot-film sensors to adjust each output. This is a delicate process as several variables drastically affect the data, including control resistance, signal input, trim, and gain settings.

  3. A Six-DOF Buoyancy Tank Microgravity Test Bed with Active Drag Compensation

    Science.gov (United States)

    Sun, Chong; Chen, Shiyu; Yuan, Jianping; Zhu, Zhanxia

    2017-10-01

    Ground experiment under microgravity is very essential because it can verify the space enabling technologies before applied in space missions. In this paper, a novel ground experiment system that can provide long duration, large scale and high microgravity level for the six degree of freedom (DOF) spacecraft trajectory tracking is presented. In which, the most gravity of the test body is balanced by the buoyancy, and the small residual gravity is offset by the electromagnetic force. Because the electromagnetic force on the test body can be adjusted in the electromagnetic system, it can significantly simplify the balancing process using the proposed microgravity test bed compared to the neutral buoyance system. Besides, a novel compensation control system based on the active disturbance rejection control (ADRC) method is developed to estimate and compensate the water resistance online, in order to improve the fidelity of the ground experiment. A six-DOF trajectory tracking in the microgravity system is applied to testify the efficiency of the proposed compensation controller, and the experimental simulation results are compared to that obtained using the classic proportional-integral-derivative (PID) method. The simulation results demonstrated that, for the six-DOF motion ground experiment, the microgravity level can reach to 5 × 10-4 g. And, because the water resistance has been estimated and compensated, the performance of the presented controller is much better than the PID controller. The presented ground microgravity system can be applied in on-orbit service and other related technologies in future.

  4. Herpes Murine Model as a Biological Assay to Test Dialyzable Leukocyte Extracts Activity

    Directory of Open Access Journals (Sweden)

    Nohemí Salinas-Jazmín

    2015-01-01

    Full Text Available Human dialyzable leukocyte extracts (DLEs are heterogeneous mixtures of low-molecular-weight peptides that are released on disruption of peripheral blood leukocytes from healthy donors. DLEs improve clinical responses in infections, allergies, cancer, and immunodeficiencies. Transferon is a human DLE that has been registered as a hemoderivate by Mexican health authorities and commercialized nationally. To develop an animal model that could be used routinely as a quality control assay for Transferon, we standardized and validated a murine model of cutaneous HSV-1 infection. Using this model, we evaluated the activity of 27 Transferon batches. All batches improved the survival of HSV-1-infected mice, wherein average survival rose from 20.9% in control mice to 59.6% in Transferon-treated mice. The activity of Transferon correlated with increased serum levels of IFN-γ and reduced IL-6 and TNF-α concentrations. Our results demonstrate that (i this mouse model of cutaneous herpes can be used to examine the activity of DLEs, such as Transferon; (ii the assay can be used as a routine test for batch release; (iii Transferon is produced with high homogeneity between batches; (iv Transferon does not have direct virucidal, cytoprotective, or antireplicative effects; and (v the protective effect of Transferon in vivo correlates with changes in serum cytokines.

  5. Test of methods for retrospective activity size distribution determination from filter samples

    International Nuclear Information System (INIS)

    Meisenberg, Oliver; Tschiersch, Jochen

    2015-01-01

    Determining the activity size distribution of radioactive aerosol particles requires sophisticated and heavy equipment, which makes measurements at large number of sites difficult and expensive. Therefore three methods for a retrospective determination of size distributions from aerosol filter samples in the laboratory were tested for their applicability. Extraction into a carrier liquid with subsequent nebulisation showed size distributions with a slight but correctable bias towards larger diameters compared with the original size distribution. Yields in the order of magnitude of 1% could be achieved. Sonication-assisted extraction into a carrier liquid caused a coagulation mode to appear in the size distribution. Sonication-assisted extraction into the air did not show acceptable results due to small yields. The method of extraction into a carrier liquid without sonication was applied to aerosol samples from Chernobyl in order to calculate inhalation dose coefficients for 137 Cs based on the individual size distribution. The effective dose coefficient is about half of that calculated with a default reference size distribution. - Highlights: • Activity size distributions can be recovered after aerosol sampling on filters. • Extraction into a carrier liquid and subsequent nebulisation is appropriate. • This facilitates the determination of activity size distributions for individuals. • Size distributions from this method can be used for individual dose coefficients. • Dose coefficients were calculated for the workers at the new Chernobyl shelter

  6. Design of a New Integrated Structure of the Active Suspension System and Emergency Lane Change Test

    Science.gov (United States)

    Zhao, Jing-bo; Liu, Hai-mei; Zhang, Lan-chun; Bei, Shao-yi

    2017-09-01

    An integrated structure of the active suspension system was proposed in order to solve the problem of the individual control of the height of the body or the adjustable damping of the active suspension system of the electric vehicle, which improve the vibration reduction performance of the vehicle. The air bag was used to replace the traditional spiral spring, and the traditional shock absorber was replaced by the damping adjustable shock absorber, and the control module received the body acceleration sensor and the horizontal height sensor signal. The system controlled adjustable damping coefficient of shock absorber through the height of the car body the output of the air pump relay and the height control valve and the output of the electromagnetic valve of the adjustable damping shock absorber, and the emergency lane change test was carried out under different modes of speed of 60km/h. The experimental results indicated that the damping value was greater, average roll angle, yaw angle and average vehicle lateral acceleration were small when vehicle body was in the state of emergency lane change, which verified the feasibility of the integrated control strategy and structure design of the active suspension system. The research has important theoretical research value and engineering application prospect for designing and controlling strategy of vehicle chassis integrated control system.

  7. APPLICATION OF RESPIROMETRIC TESTS FOR ASSESSMENT OF METHANOGENIC BACTERIA ACTIVITY IN WASTEWATER SLUDGE PROCESSING

    Directory of Open Access Journals (Sweden)

    Małgorzata Cimochowicz-Rybicka

    2013-07-01

    Full Text Available Production of a methane-rich gas (‘biogas’ is contemporary popular sludges processing technology which allows to generate thermal and/or electric energy. Formal requirements issued by the European Union to promote so called renewable energy resources made these process more attractive leading to its application in WWTPs which were designed based on different sludge handling processes. Authors (as active design engineers noted that dimensioning sludge digestion chamber is usually based on SRT assessment without any emphasis on sludge characteristics. Bio-mass characteristics and the estimation of its activity with respect to methane production are of great importance, from both scientific and practical points of view, as anaerobic digestion appears to be one of crucial processes in municipal wastewater handling and disposal. The authors propose respirometric tests to estimate a biomass potential to produce ‘a biogas’ and several years’ laboratory and full scale experience proved its usefulness and reliability both as a measurement and a design tool applicable in sludge handling. Dimensioning method proposed by authors, allows to construct and optimize operation of digestion chambers based on a methanogenic activity.

  8. Testing of different data libraries in activation analysis of concrete and graphite from nuclear installations

    International Nuclear Information System (INIS)

    Cometto, M.; Ancius, D.; Ridikas, D.

    2003-01-01

    With the aging of the nuclear park, decommissioning and dismantling of nuclear installations after their service life is becoming an important issue for the nuclear industry. The radiological characterisation of the equipment and structures present in the reactor and its environment is an essential stage in a decommissioning project since it permits to define and optimize the decommissioning strategy and the disassembling operations. In addition, correct activation estimates are essential for determining the quantity and the nature of the radiological waste generated during decommissioning. The adoption of efficient dismantling procedures and the optimization of the mass flow going to different waste repositories might reduce substantially the total cost of decommissioning. The present work has been done in the framework of the decommissioning and dismantling of the experimental reactor of the University of Strasbourg (RUS). A methodology that combines theoretical calculations and direct measurements has been developed for determining the long-term induced activity in the graphite, concrete and materials present in the reactor. After characterisation of the different elements present in the reactor, it is then possible to plan efficiently the disassembling and dismantling of the system and to optimise the mass flow going to different waste repositories. From a scientific perspective, the comparison of theoretical predictions with experimental values validates the approach and the methodology used in the present study and tests the consistency and the reliability of the nuclear data used for activation analysis. (orig.)

  9. Tests of Micro-Pattern Gaseous Detectors for active target time projection chambers in nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Pancin, J., E-mail: pancin@ganil.fr [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France); Damoy, S.; Perez Loureiro, D. [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France); Chambert, V.; Dorangeville, F. [IPNO, CNRS/IN2P3, Orsay (France); Druillole, F. [CEA, DSM/Irfu/SEDI, Gif-Sur-Yvette (France); Grinyer, G.F. [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France); Lermitage, A.; Maroni, A.; Noël, G. [IPNO, CNRS/IN2P3, Orsay (France); Porte, C.; Roger, T. [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France); Rosier, P. [IPNO, CNRS/IN2P3, Orsay (France); Suen, L. [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France)

    2014-01-21

    Active target detection systems, where the gas used as the detection medium is also a target for nuclear reactions, have been used for a wide variety of nuclear physics applications since the eighties. Improvements in Micro-Pattern Gaseous Detectors (MPGDs) and in micro-electronics achieved in the last decade permit the development of a new generation of active targets with higher granularity pad planes that allow spatial and time information to be determined with unprecedented accuracy. A novel active target and time projection chamber (ACTAR TPC), that will be used to study reactions and decays of exotic nuclei at facilities such as SPIRAL2, is presently under development and will be based on MPGD technology. Several MPGDs (Micromegas and Thick GEM) coupled to a 2×2 mm{sup 2} pixelated pad plane have been tested and their performances have been determined with different gases over a wide range of pressures. Of particular interest for nuclear physics experiments are the angular and energy resolutions. The angular resolution has been determined to be better than 1° FWHM for short traces of about 4 cm in length and the energy resolution deduced from the particle range was found to be better than 5% for 5.5 MeV α particles. These performances have been compared to Geant4 simulations. These experimental results validate the use of these detectors for several applications in nuclear physics.

  10. Tests of Micro-Pattern Gaseous Detectors for active target time projection chambers in nuclear physics

    International Nuclear Information System (INIS)

    Pancin, J.; Damoy, S.; Perez Loureiro, D.; Chambert, V.; Dorangeville, F.; Druillole, F.; Grinyer, G.F.; Lermitage, A.; Maroni, A.; Noël, G.; Porte, C.; Roger, T.; Rosier, P.; Suen, L.

    2014-01-01

    Active target detection systems, where the gas used as the detection medium is also a target for nuclear reactions, have been used for a wide variety of nuclear physics applications since the eighties. Improvements in Micro-Pattern Gaseous Detectors (MPGDs) and in micro-electronics achieved in the last decade permit the development of a new generation of active targets with higher granularity pad planes that allow spatial and time information to be determined with unprecedented accuracy. A novel active target and time projection chamber (ACTAR TPC), that will be used to study reactions and decays of exotic nuclei at facilities such as SPIRAL2, is presently under development and will be based on MPGD technology. Several MPGDs (Micromegas and Thick GEM) coupled to a 2×2 mm 2 pixelated pad plane have been tested and their performances have been determined with different gases over a wide range of pressures. Of particular interest for nuclear physics experiments are the angular and energy resolutions. The angular resolution has been determined to be better than 1° FWHM for short traces of about 4 cm in length and the energy resolution deduced from the particle range was found to be better than 5% for 5.5 MeV α particles. These performances have been compared to Geant4 simulations. These experimental results validate the use of these detectors for several applications in nuclear physics

  11. Road map for the clinical application of the basophil activation test in food allergy.

    Science.gov (United States)

    Santos, A F; Shreffler, W G

    2017-09-01

    The diagnosis of IgE-mediated food allergy based solely on the clinical history and the documentation of specific IgE to whole allergen extract or single allergens is often ambiguous, requiring oral food challenges (OFCs), with the attendant risk and inconvenience to the patient, to confirm the diagnosis of food allergy. This is a considerable proportion of patients assessed in allergy clinics. The basophil activation test (BAT) has emerged as having superior specificity and comparable sensitivity to diagnose food allergy, when compared with skin prick test and specific IgE. BAT, therefore, may reduce the number of OFC required for accurate diagnosis, particularly positive OFC. BAT can also be used to monitor resolution of food allergy and the clinical response to immunomodulatory treatments. Given the practicalities involved in the performance of BAT, we propose that it can be applied for selected cases where the history, skin prick test and/or specific IgE are not definitive for the diagnosis of food allergy. In the cases that the BAT is positive, food allergy is sufficiently confirmed without OFC; in the cases that BAT is negative or the patient has non-responder basophils, OFC may still be indicated. However, broad clinical application of BAT demands further standardization of the laboratory procedure and of the flow cytometry data analyses, as well as clinical validation of BAT as a diagnostic test for multiple target allergens and confirmation of its feasibility and cost-effectiveness in multiple settings. © 2017 The Authors. Clinical & Experimental Allergy published by John Wiley & Sons Ltd.

  12. [The role of the basophil activation test (BAT) in qualification for specific immunotherapy with inhalant allergens].

    Science.gov (United States)

    Bulanda, Małgorzata; Dyga, Wojciech; Rusinek, Barbara; Czarnobilska, Ewa

    Qualification for specific immunotherapy (SIT) according to the guidelines of the European Academy of Allergy and Clinical Immunology (EAACI) includes medical history, skin prik tests (SPT) and/or measuring the concentration of sIgE. It is necessary to perform additional diagnostic tests in case of discrepancies between the history and the results of SPT/sIgE or differences between SPT and sIgE. Basophil activation test (BAT) assesses the expression of activation markers of these cells, eg. CD63 and CD203c after stimulation. The aim of our study was to evaluate the usefulness of BAT in the qualification for the SIT in comparison to the SPT and sIgE and in case of discrepancies between the results of SPT and sIgE. The study included 30 patients with allergic rhinitis (AR) caused by allergy to house dust mite (Dermatophagoides pteronyssinus, Dp) or birch pollen qualified for SIT. All patients had SPT, sIgE and BAT determination. The group of patients with allergy to birch was a control group for Dp allergic and vice versa. BAT with CD63 antigen expression was performed using a Flow2CAST test. Basophils were stimulated with allergen preparation (50, 500, and 5000 SBU/ml concentrations). BAT results were expressed as a stimulation index (SI). For optimal concentrations of 50 and 500 SBU/ml parameters comparing BAT to SPT and sIgE as the gold standards were consecutively: sensitivity 82-100% and 93-100%, specificity 50-94% and 47-89%, positive predictive value 65- 94% and 61-87%, negative predictive value 86-100% and 93-100%. Correlation BAT - SPT and BAT - sIgE ranged within 0.59 to 0.84 and 0.51 to 0.72. BAT was helpful in 2 of 30 patients with incompatible results of SPT and sIgE. Optimal concentrations for basophil stimulation are 50 and 500 SBU/ ml. BAT may be useful diagnostic tool in the qualification for the SIT in case of discrepancies between the results of SPT and sIgE.

  13. Development of Reduced Activation Ferritic-Martensitic Steels and fabrication technologies for Indian test blanket module

    Energy Technology Data Exchange (ETDEWEB)

    Raj, Baldev [Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Jayakumar, T., E-mail: tjk@igcar.gov.in [Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)

    2011-10-01

    For the development of Reduced Activation Ferritic-Martensitic Steel (RAFMS), for the Indian Test Blanket Module for ITER, a 3-phase programme has been adopted. The first phase consists of melting and detailed characterization of a laboratory scale heat conforming to Eurofer 97 composition, to demonstrate the capability of the Indian industry for producing fusion grade steel. In the second phase which is currently in progress, the chemical composition will be optimized with respect to tungsten and tantalum for better combination of mechanical properties. Characterization of the optimized commercial scale India-specific RAFM steel will be carried out in the third phase. The first phase of the programme has been successfully completed and the tensile, impact and creep properties are comparable with Eurofer 97. Laser and electron beam welding parameters have been optimized and welding consumables were developed for Narrow Gap - Gas Tungsten Arc welding and for laser-hybrid welding.

  14. Technical issues of reduced activation ferritic/martensitic steels for fabrication of ITER test blanket modules

    International Nuclear Information System (INIS)

    Tanigawa, H.; Hirose, T.; Shiba, K.; Kasada, R.; Wakai, E.; Serizawa, H.; Kawahito, Y.; Jitsukawa, S.; Kimura, A.; Kohno, Y.; Kohyama, A.; Katayama, S.; Mori, H.; Nishimoto, K.; Klueh, R.L.; Sokolov, M.A.; Stoller, R.E.; Zinkle, S.J.

    2008-01-01

    Reduced activation ferritic/martensitic steels (RAFMs) are recognized as the primary candidate structural materials for fusion blanket systems. The RAFM F82H was developed in Japan with emphasis on high-temperature properties and weldability. Extensive irradiation studies have conducted on F82H, and it has the most extensive available database of irradiated and unirradiated properties of all RAFMs. The objective of this paper is to review the R and D status of F82H and to identify the key technical issues for the fabrication of an ITER test blanket module (TBM) suggested from the recent research achievements in Japan. This work clarified that the primary issues with F82H involve welding techniques and the mechanical properties of weld joints. This is the result of the distinctive nature of the joint caused by the phase transformation that occurs in the weld joint during cooling, and its impact on the design of a TBM will be discussed

  15. Comparison of analysis and flight test data for a drone aircraft with active flutter suppression

    Science.gov (United States)

    Newsom, J. R.; Pototzky, A. S.

    1981-01-01

    A drone aircraft equipped with an active flutter suppression system is considered with emphasis on the comparison of modal dampings and frequencies as a function of Mach number. Results are presented for both symmetric and antisymmetric motion with flutter suppression off. Only symmetric results are given for flutter suppression on. Frequency response functions of the vehicle are presented from both flight test data and analysis. The analysis correlation is improved by using an empirical aerodynamic correction factor which is proportional to the ratio of experimental to analytical steady-state lift curve slope. The mathematical models are included and existing analytical techniques are described as well as an alternative analytical technique for obtaining closed-loop results.

  16. Determination of taste-active compounds of a bitter Camembert cheese by omission tests.

    Science.gov (United States)

    Engel, E; Septier, C; Leconte, N; Salles, C; Le Quere, J L

    2001-11-01

    The taste-active compounds of a Camembert cheese selected for its intense bitterness defect were investigated. The water-soluble fraction (WSE) was extracted with pure water and fractionated by successive tangential ultrafiltrations and nanofiltration. The physicochemical assessment of these fractions led to the construction of a model WSE which was compared by sensory evaluation to the crude water-soluble extract, using a panel of 16 trained tasters. As no significant difference was perceived, this model WSE was then used directly or mixed with other cheese components for omission tests. Among the main taste characteristics of the WSE (salty, sour, umami and bitter), bitterness was found to be due to small peptides whose mass distribution was obtained by RPHPLC-MS (400-3000 Da) and whose taste properties are discussed.

  17. Non Destructive Testing by active infrared thermography coupled with shearography under same optical heat excitation

    Science.gov (United States)

    Theroux, Louis-Daniel; Dumoulin, Jean; Maldague, Xavier

    2014-05-01

    As infrastructures are aging, the evaluation of their health is becoming crucial. To do so, numerous Non Destructive Testing (NDT) methods are available. Among them, thermal shearography and active infrared thermography represent two full field and contactless methods for surface inspection. The synchronized use of both methods presents multiples advantages. Most importantly, both NDT are based on different material properties. Thermography depend on the thermal properties and shearography on the mechanical properties. The cross-correlation of both methods result in a more accurate and exact detection of the defects. For real site application, the simultaneous use of both methods is simplified due to the fact that the excitation method (thermal) is the same. Active infrared thermography is the measure of the temperature by an infrared camera of a surface subjected to heat flux. Observation of the variation of temperature in function of time reveal the presence of defects. On the other hand, shearography is a measure of out-of-plane surface displacement. This displacement is caused by the application of a strain on the surface which (in our case) take the form of a temperature gradient inducing a thermal stress To measure the resulting out-of-plane displacement, shearography exploit the relation between the phase difference and the optical path length. The phase difference is measured by the observation of the interference between two coherent light beam projected on the surface. This interference is due to change in optical path length as the surface is deformed [1]. A series of experimentation have been conducted in laboratory with various sample of concrete reinforced with CFRP materials. Results obtained reveal that with both methods it was possible to detect defects in the gluing. An infrared lamp radiating was used as the active heat source. This is necessary if measurements with shearography are to be made during the heating process. A heating lamp in the

  18. [Renin-angiotensin-aldosterone system activity during head-up tilt testing in patients with vasovagal syncope].

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Mazurek, Walentyna

    2005-08-01

    The stimulation of renin-angiotensin-aldosterone (RAA) system during tilt table test is caused by sympathetic nervous system activation by orthostatic stress and a serotonin release as well. In healthy individuals increase of plasma renin activity during test with maximal values on the peak of the test was described. The aim of the study was to assess the activation of RAAS in patients with neurally mediated syncope during the tilt table test by means of plasma renin activity and serum aldosterone levels. The study was carried out in 31 patients aged 39.4 +/- 15.0 years (18 women and 13 men) with neurally mediated syncope during tilt test. Plasma renin activity was assessed in the baseline conditions, immediately after the test and 10 minutes after the test using radioenzymatic assay. Aldosterone concentrations were measured radioimmunologically, twice: after 30 minutes supine rest and after the syncope. Plasma renin activity during supine rest was 2.2 +/- 2.4 ng/ml/h, rose after the syncope 2.5-fold to 5.2 +/- 4.5 ng/ml/h (p < 0.001 comparing to baseline) stayed on similar level approximately for the next 10 minutes--4.9 +/- 5.5 ng/ml/h (p = n.s.). In 11 patients (35%) 10 minutes after the test even further increase of PRA was observed. Serum aldosterone level increased significantly immediately after tilt test (90.0 +/- 72.9 vs 178.8 +/- 150.1 pg/ml, p < 0.01). Authors showed, that in patients with NMS plasma renin activity increases and this increase lasts for 10 minutes after the syncope and the concentration of aldosterone increases immediately after tilt test.

  19. Differences in cortical and pituitary activity in response to hypoglycaemia and cognitive testing in healthy men with different basal activity of the renin-angiotensin system

    DEFF Research Database (Denmark)

    Bie-Olsen, Lise G; Pedersen-Bjergaard, Ulrik; Kjaer, Troels W

    2010-01-01

    in cerebral activity during hypoglycaemia and cognitive testing in two groups of healthy men with different basal RAS activity. METHODS: Ten healthy men with high RAS activity and 10 with low activity underwent six oxygen-15-labelled water positron emission tomography scans: twice during normoglycaemia, twice......INTRODUCTION: High renin-angiotensin system (RAS) activity has been associated with a high risk of severe hypoglycaemia in patients with type 1 diabetes and with cognitive deterioration during experimental hypoglycaemia in healthy subjects. The aim of this study was to describe possible differences...... during insulin-induced hypoglycaemia and twice during post-hypoglycaemia. During the scans, the subjects performed a computer-based reaction time test. RESULTS: Occipital areas were consistently more activated in the low RAS group than in the high RAS group throughout all three conditions. During...

  20. Development of Simulants to Support Mixing Tests for High Level Waste and Low Activity Waste

    International Nuclear Information System (INIS)

    EIBLING, RUSSELLE.

    2004-01-01

    The objectives of this study were to develop two different types of simulants to support vendor agitator design studies and mixing studies. The initial simulant development task was to develop rheologically-bounding physical simulants and the final portion was to develop a nominal chemical simulant which is designed to match, as closely as possible, the actual sludge from a tank. The physical simulants to be developed included a lower and upper rheologically bounded: pretreated low activity waste (LAW) physical simulant; LAW melter feed physical simulant; pretreated high level waste (HLW) physical simulant; HLW melter feed physical simulant. The nominal chemical simulant, hereafter referred to as the HLW Precipitated Hydroxide simulant, is designed to represent the chemical/physical composition of the actual washed and leached sludge sample. The objective was to produce a simulant which matches not only the chemical composition but also the physical properties of the actual waste sample. The HLW Precipitated Hydroxide simulant could then be used for mixing tests to validate mixing, homogeneity and representative sampling and transferring issues. The HLW Precipitated Hydroxide simulant may also be used for integrated nonradioactive testing of the WTP prior to radioactive operation

  1. Active self-testing noise measurement sensors for large-scale environmental sensor networks.

    Science.gov (United States)

    Domínguez, Federico; Cuong, Nguyen The; Reinoso, Felipe; Touhafi, Abdellah; Steenhaut, Kris

    2013-12-13

    Large-scale noise pollution sensor networks consist of hundreds of spatially distributed microphones that measure environmental noise. These networks provide historical and real-time environmental data to citizens and decision makers and are therefore a key technology to steer environmental policy. However, the high cost of certified environmental microphone sensors render large-scale environmental networks prohibitively expensive. Several environmental network projects have started using off-the-shelf low-cost microphone sensors to reduce their costs, but these sensors have higher failure rates and produce lower quality data. To offset this disadvantage, we developed a low-cost noise sensor that actively checks its condition and indirectly the integrity of the data it produces. The main design concept is to embed a 13 mm speaker in the noise sensor casing and, by regularly scheduling a frequency sweep, estimate the evolution of the microphone's frequency response over time. This paper presents our noise sensor's hardware and software design together with the results of a test deployment in a large-scale environmental network in Belgium. Our middle-range-value sensor (around €50) effectively detected all experienced malfunctions, in laboratory tests and outdoor deployments, with a few false positives. Future improvements could further lower the cost of our sensor below €10.

  2. Crucible of Creativity: Testing Public Outreach Activities at the Phoenix Comicon

    Science.gov (United States)

    Horodyskyj, L.

    2015-12-01

    The Phoenix Comicon (PCC) is a growing four-day pop culture event that features guests, costuming, exhibits, and discussion panels for popular sci-fi, fantasy, horror, and anime franchises. The 2014 and 2015 shows (which drew 75,000+ unique attendees each) featured a science programming track coordinated and organized by Horodyskyj. The track consisted of discussion panels, mixers, shows, interactive displays, and signature events (over 30 hours of programming each year). Topics ranged from planetary sciences to biotechnology to artificial intelligence and event staff were recruited from all levels of experience in academia, industry, and STEM outreach. The PCC science programming track for both 2014 and 2015 received very positive feedback from the audience, PCC management, and even scientists who participated in the event. Panelists and staff received frequent unsolicited praise about the content and events, and surveys showed requests for more science content in future years. Demand for good science programming, especially the kind that links the audience to local scientists, is high. The unique organizational structure of PCC, which draws heavily on the fan community rather than industry professionals, provides a rich test bed for public outreach activities generated by scientists themselves. In 2014, we tested science-based game shows, such as the bloody Exoplanet Survivor. In 2015, we ran a science interactivity booth and an interactive stage show about forensics based on the BBC series Sherlock. I will detail some of the successes and failures of these various events and what we're planning for 2016.

  3. Assessment of a Newly Developed, Active Pneumatic-Driven, Sensorimotor Test and Training Device

    Directory of Open Access Journals (Sweden)

    Wolfram Haslinger

    2014-12-01

    Full Text Available The sensorimotor system (SMS plays an important role in sports and in every day movement. Several tools for assessment and training have been designed. Many of them are directed to specific populations, and have major shortcomings due to the training effect or safety. The aim of the present study was to design and assess a dynamic sensorimotor test and training device that can be adjusted for all levels of performance. The novel pneumatic-driven mechatronic device can guide the trainee, allow independent movements or disrupt the individual with unpredicted perturbations while standing on a platform. The test-reliability was evaluated using intraclass correlation coefficient (ICC. Subjects were required to balance their center of pressure (COP in a target circle (TITC. The time in TITC and the COP error (COPe were recorded for analysis. The results of 22 males and 14 females (23.7 ± 2.6 years showed good to excellent test–retest reliability. The newly designed Active Balance System (ABS was then compared with the Biodex Balance System SD® (BBS. The results of 15 females, 14 males (23.4 ± 1.6 years showed modest correlation in static and acceptable correlation in dynamic conditions, suggesting that ABS could be a reliable and comparable tool for dynamic balance assessments.

  4. TTC- Based Test as an Efficient Method to Determine Antibiofilm Activity of Silver Nanoparticles

    Directory of Open Access Journals (Sweden)

    Chojniak Joanna

    2017-01-01

    Full Text Available Among metal nanoparticles, silver nanoparticles are a widely used in various life sectors such as in biomedical applications, air and water purification, food production, cosmetics, garments and in various household products. There are several methods for production of silver nanoparticles. Generally, silver nanoparticles can be prepared by chemical methods such as chemical reduction and electrochemical techniques, physical methods, and biological methods such as the use of microorganisms. The biological route of synthesis provides a great diversity in choice for its raw materials such as bacteria, algae, fungi and plants. The aim of the study was to evaluate the tetrazolium/formazan test as a method to determine antibiofilm activity of biological synthetized silver nanoparticles. In this study Bacillus subtilis grown on brewery effluent and produced biosurfactant was used for silver nanoparticles (Ag-NPs synthesis. The culture supernatants were used in synthesis of Ag-NPs. The formation of nanoparticles accompanied by colour changes of the used reaction system was confirmed by UV-vis spectroscopy. The bacteria isolated from the biofilm of water supply system were used in the evaluation of the antibiofilm activity of biologically synthetized Ag-NPs. To compare the results the commonly used crystal violet assay (CV for biofilm analysis was applied.

  5. Predictors of physical activity in persons with mental illness: Testing a social cognitive model.

    Science.gov (United States)

    Zechner, Michelle R; Gill, Kenneth J

    2016-12-01

    This study examined whether the social cognitive theory (SCT) model can be used to explain the variance in physical exercise among persons with serious mental illnesses. A cross-sectional, correlational design was employed. Participants from community mental health centers and supported housing programs (N = 120) completed 9 measures on exercise, social support, self-efficacy, outcome expectations, barriers, and goal-setting. Hierarchical regression tested the relationship between self-report physical activity and SCT determinants while controlling for personal characteristics. The model explained 25% of the variance in exercise. Personal characteristics explained 18% of the variance in physical activity, SCT variables of social support, self-efficacy, outcome expectations, barriers, and goals were entered simultaneously, and they added an r2 change value of .07. Gender (β = -.316, p = .001) and Brief Symptom Inventory Depression subscale (β = -2.08, p exercise. In a separate stepwise multiple regression, we entered only SCT variables as potential predictors of exercise. Goal-setting was the single significant predictor, F(1, 118) = 13.59, p exercise in persons with mental illnesses. Goal-setting practices, self-efficacy, outcome expectations and social support from friends for exercise should be encouraged by psychiatric rehabilitation practitioners. People with more depressive symptoms and women exercise less. More work is needed on theoretical exploration of predictors of exercise. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  6. Design and Test of an Event Detector and Locator for the ReflectoActive Seals System

    International Nuclear Information System (INIS)

    Stinson, Brad J.

    2006-01-01

    The purpose of this work was to research, design, develop and test a novel instrument for detecting fiber optic loop continuity and spatially locating fiber optic breaches. The work is for an active seal system called ReflectoActive(trademark) Seals whose purpose is to provide real time container tamper indication. A Field Programmable Gate Array was used to implement a loop continuity detector and a spatial breach locator based on a high acquisition speed single photon counting optical time domain reflectometer. Communication and other control features were added in order to create a usable instrument that met defined requirements. A host graphical user interface was developed to illustrate system use and performance. The resulting device meets performance specifications by exhibiting a dynamic range of 27dB and a spatial resolution of 1.5 ft. The communication scheme used expands installation options and allows the device to communicate to a central host via existing Local Area Networks and/or the Internet.

  7. Antibacterial Free Fatty Acids and Monoglycerides: Biological Activities, Experimental Testing, and Therapeutic Applications

    Science.gov (United States)

    Yoon, Bo Kyeong; Jackman, Joshua A.; Valle-González, Elba R.

    2018-01-01

    Antimicrobial lipids such as fatty acids and monoglycerides are promising antibacterial agents that destabilize bacterial cell membranes, causing a wide range of direct and indirect inhibitory effects. The goal of this review is to introduce the latest experimental approaches for characterizing how antimicrobial lipids destabilize phospholipid membranes within the broader scope of introducing current knowledge about the biological activities of antimicrobial lipids, testing strategies, and applications for treating bacterial infections. To this end, a general background on antimicrobial lipids, including structural classification, is provided along with a detailed description of their targeting spectrum and currently understood antibacterial mechanisms. Building on this knowledge, different experimental approaches to characterize antimicrobial lipids are presented, including cell-based biological and model membrane-based biophysical measurement techniques. Particular emphasis is placed on drawing out how biological and biophysical approaches complement one another and can yield mechanistic insights into how the physicochemical properties of antimicrobial lipids influence molecular self-assembly and concentration-dependent interactions with model phospholipid and bacterial cell membranes. Examples of possible therapeutic applications are briefly introduced to highlight the potential significance of antimicrobial lipids for human health and medicine, and to motivate the importance of employing orthogonal measurement strategies to characterize the activity profile of antimicrobial lipids. PMID:29642500

  8. Towards magnetic liquefaction of hydrogen: experiments with an active magnetic regenerator test apparatus

    International Nuclear Information System (INIS)

    Richard, M.-A.; Rowe, A.M.; Chahine, R.; Bose, T.; Barclay, J.A.

    2003-01-01

    Refrigeration based on an Active Magnetic Regenerative (AMR) cycle has the potential to be a more efficient way of liquefying hydrogen than conventional gas cycles. Because the magnetocaloric effect decreases quickly for most materials as the temperature moves away from the phase transition region, the combination of many magnetic refrigerants in a multi-layers active magnetic regenerator is needed as a way to produce larger temperature spans for each stage of a liquefier. An investigation of a multi layer regenerator has been performed using an AMR test apparatus (AMRTA). Gadolinium and a gadolinium-terbium alloy were used as the two layers in the fabrication of two reciprocating multi-layer regenerators working near room temperature. The performances of the multi-material regenerator is compared to a Gd regenerator in terms of temperature span (respectively 20 K and 16 K at 2 Tesla respectively) and cooling power. For the first time, a multi-material AMR has been shown to produce a larger temperature span and cooling power than a single material of equivalent mass and geometry. (author)

  9. An experimental test of control theory-based interventions for physical activity.

    Science.gov (United States)

    Prestwich, Andrew; Conner, Mark; Hurling, Robert; Ayres, Karen; Morris, Ben

    2016-11-01

    To provide an experimental test of control theory to promote physical activity. Parallel groups, simple randomized design with an equal chance of allocation to any group. Participants not meeting recommended levels of physical activity but physically safe to do so (N = 124) were recruited on a UK university campus and randomized to goal-setting + self-monitoring + feedback (GS + SM + F, n = 40), goal-setting + self-monitoring (GS + SM, n = 40), or goal-setting only (GS, n = 44) conditions that differentially tapped the key features of control theory. Accelerometers assessed physical activity (primary outcome) as well as self-report over a 7-day period directly before/after the start of the intervention. The participants in the GS + SM + F condition significantly outperformed those in the GS condition, d = 0.62, 95% CI d = 0.15-1.08, and marginally outperformed those in the GS + SM condition in terms of total physical activity at follow-up on the accelerometer measure, d = 0.33, 95% CI d = -0.13 to 0.78. The feedback manipulation (GS + SM + F vs. GS + SM and GS) was most effective when baseline intentions were weak. These patterns did not emerge on the self-report measure but, on the basis of this measure, the feedback manipulation increased the risk that participants coasted in relation to their goal in the first few days of the intervention period. Using behaviour change techniques consistent with control theory can lead to significant short-term improvements on objectively assessed physical activity. Further research is needed to examine the underlying theoretical principles of the model. Statement of contribution What is already known on this subject? Interventions incorporating more techniques that are consistent with control theory are associated with larger positive changes in health behaviours and related outcomes (see reviews by Dombrowski et al., ; Michie et al., ). However, none of the studies included in these

  10. Evaluation of the antinociceptive activities of enaminone compounds on the formalin and hot plate tests in mice

    Science.gov (United States)

    Masocha, Willias; Kombian, Samuel B.; Edafiogho, Ivan O.

    2016-02-01

    Recently, we found that methyl 4-(4‧-bromophenyl)aminocyclohex-3-en-6-methyl-2-oxo-1-oate (E139), an anticonvulsant enaminone, has antinociceptive activity in the hot plate test. In this study we evaluated the antinociceptive activity of five anilino enaminones E139, ethyl 4-(4‧-chlorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E121), ethyl 4-(4‧-bromophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E122), methyl 4-(4‧-chlorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E138) and ethyl 4-(4‧-fluorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (BRG 19) using the formalin and hot plate tests. E139 has been reported to exert its effects via enhancement of extracellular GABA levels, thus tiagabine, a GABA transporter inhibitor, was evaluated as a control together with indomethacin. Tiagabine had antinociceptive activity in both phase 1 (neurogenic pain) and phase 2 (inflammatory pain) of the formalin test, whereas indomethacin had activity only in phase 2. E139 and E138 had antinociceptive activity in both phases of the formalin test, whereas E121 had activity only in phase 1 and BRG 19 had activity only in phase 2. E122 had no significant activity in either phase. In the hot plate test only E139 had antinociceptive activity. Administration of either bicuculline, a GABAA receptor antagonist, or CGP 35348, a GABAB receptor antagonist, blocked the antinociceptive activity of E139. In conclusion our results indicate that E139 has antinociceptive activity in the formalin and hot plate tests that are dependent on GABA receptors.

  11. In vitro antimicrobial activity of linezolid tested against vancomycin-resistant enterococci isolated in Brazilian hospitals

    Directory of Open Access Journals (Sweden)

    Reis Adriana O.

    2001-01-01

    Full Text Available The emergence of vancomycin-resistant enterococci (VRE has been described recently in Brazil. This is in contrast to the USA and Europe, where the VRE appeared in the late 1980s. The progressive increase in VRE isolation poses important problems in the antimicrobial therapy of nosocomial infections. Treatment options and effective antimicrobial agents for VRE are often limited and the possibility of transfer of vancomycin genes to other Gram-positive microorganisms continues. In the search for antimicrobial agents for multiresistant Gram-positive cocci, compounds such as linezolid and quinupristin/dalfopristin have been evaluated. The present study was conducted to evaluate the in vitro activity of the oxazolidinone linezolid and 10 other antimicrobial agents, including quinupristin-dalfopristin, against multiresistant enterococci isolated in Brazilian hospitals. Thirty-three vancomycin resistant isolates (17 Enterococcus faecium and 16 E. faecalis, were analyzed. Strains were isolated from patients at São Paulo Hospital, Oswaldo Cruz Hospital, Hospital do Servidor Público Estadual, Santa Marcelina Hospital, Santa Casa de Misericórdia de São Paulo, and Hospital de Clínicas do Paraná. The samples were tested by a broth microdilution method following the National Committee for Clinical Laboratory Standards (NCCLS recommendations. All isolates were molecular typed using pulsed-field gel electrophoresis (PFGE. Linezolid was the most active compound against these multiresistant enterococci, showing 100% inhibition at the susceptible breakpoints. Quinupristin/dalfopristin and teicoplanin showed poor activity against both species. The molecular typing results suggest that there has been interhospital spread of vancomycin resistant E. faecium and E. faecalis among Brazilian hospitals. The results of this study indicate that linezolid is an appropriate therapeutic option for the treatment of vancomycin-resistant enterococci infections in Brazil.

  12. A Community Based Study to Test the Reliability and Validity of Physical Activity Measurement Techniques

    Directory of Open Access Journals (Sweden)

    Puneet Misra

    2014-01-01

    Full Text Available Introduction: Physical activity (PA is protective against non-communicable diseases and it can reduce premature mortality. However, it is difficult to assess the frequency, duration, type and intensity of PA. The global physical activity questionnaire (GPAQ has been developed by World Health Organization with the aim of having valid and reliable estimates of PA. The primary aim of this study is to assess the repeatability of the GPAQ instrument and the secondary aim is to validate it against International Physical Activity Questionnaire (IPAQ and against an objective measure of PA (i.e., using pedometers in both rural and peri-urban areas of North India. Methods: A total of 262 subjects were recruited by random selection from Ballabgarh Block of Haryana State in India. For test retest repeatability of GPAQ and IPAQ, the instruments were administered on two occasions separated by at least 3 days. For concurrent validity, both questionnaires were administered in random order and for criterion validity step counters were used. Spearman′s correlation coefficient, intra-class correlation (ICC and Cohen′s kappa was used in the analysis. Results: For GPAQ validity, the spearman′s Rho ranged from 0.40 to 0.59 and ICC ranged from 0.43 to 0.81 while for IPAQ validity, spearman correlation coefficient ranged from 0.42 to 0.43 and ICC ranged from 0.56 to 0.68. The observed concurrent validity coefficients suggested that both the questionnaires had reasonable agreement (Spearman Rho of >0.90; P < 0.0001; ICC: 0.76-0.91, P < 0.05. Conclusions: GPAQ is similar to IPAQ in measuring PA and can be used for measurement of PA in community settings.

  13. Examples of verification knowledge and testing of the secondary students through the worksheet. Suggestions for leisure time activities

    International Nuclear Information System (INIS)

    Chmielewska, E.; Kuruc, J.

    2010-01-01

    In this chapter some examples of verification knowledge and testing of the secondary students through the worksheet as well as suggestions for leisure time activities are presented. Used and recommended literature is included.

  14. Laboratory Evaporation Testing Of Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, Duane J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nash, Charles A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, Daniel J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Crawford, Charles L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Wilmarth, William R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-01-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream, LAW Off-Gas Condensate, from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of canistered glass waste forms. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to be within acceptable concentration ranges in the LAW glass. Diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task examines the impact of potential future disposition of this stream in the Hanford tank farms, and investigates auxiliary evaporation to enable another disposition path. Unless an auxiliary evaporator is used, returning the stream to the tank farms would require evaporation in the 242-A evaporator. This stream is expected to be unusual because it will be very high in corrosive species that are volatile in the melter

  15. Laboratory Evaporation Testing Of Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant

    International Nuclear Information System (INIS)

    Adamson, Duane J.; Nash, Charles A.; McCabe, Daniel J.; Crawford, Charles L.; Wilmarth, William R.

    2014-01-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream, LAW Off-Gas Condensate, from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of canistered glass waste forms. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to be within acceptable concentration ranges in the LAW glass. Diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task examines the impact of potential future disposition of this stream in the Hanford tank farms, and investigates auxiliary evaporation to enable another disposition path. Unless an auxiliary evaporator is used, returning the stream to the tank farms would require evaporation in the 242-A evaporator. This stream is expected to be unusual because it will be very high in corrosive species that are volatile in the melter

  16. In vitro metabolism and bioavailability tests for endocrine active substances: What is needed next for regulatory purposes?

    Science.gov (United States)

    Legistation and prospective legislative proposals internationally (may) require that chemicals be tested for their ability to disrupt the hormonal systems of mammals. Chemicals found to test positive in vitro are considered to be endocrine active substances (EAS) and may be puta...

  17. Evaluation of the nitrite and leukocyte esterase activity tests for the diagnosis of acute symptomatic urinary tract infection in men.

    NARCIS (Netherlands)

    Koeijers, J.J.; Kessels, A.G.H.; Nys, S.; Bartelds, A.; Donker, G.; Stobberingh, E.; Verbon, A.

    2007-01-01

    For 422 male patients with symptoms indicative of a urinary tract infection, nitrite and leukocyte esterase activity dipstick test results were compared with results of culture of urine samples. The positive predictive value of a positive nitrite test result was 96%. Addition of results of the

  18. Development and Testing of a Nutrition, Food Safety, and Physical Activity Checklist for EFNEP and FSNE Adult Programs

    Science.gov (United States)

    Bradford, Traliece; Serrano, Elena L.; Cox, Ruby H.; Lambur, Michael

    2010-01-01

    Objective: To develop and assess reliability and validity of the Nutrition, Food Safety, and Physical Activity Checklist to measure nutrition, food safety, and physical activity practices among adult Expanded Food and Nutrition Education Program (EFNEP) and Food Stamp Nutrition Education program (FSNE) participants. Methods: Test-retest…

  19. Iodine adsorption on ion-exchange resins and activated carbons: batch testing

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Kent E.; Golovich, Elizabeth C.; Wellman, Dawn M.

    2014-09-30

    Iodine sorption onto seven resins and six carbon materials was evaluated using water from well 299-W19-36 on the Hanford Site. These materials were tested using a range of solution-to-solid ratios. The test results are as follows. The efficacy of the resin and granular activated carbon materials was less than predicted based on manufacturers’ performance data. It is hypothesized that this is due to the differences in speciation previously determined for Hanford groundwater. The sorption of iodine is affected by the iodine species in the source water. Iodine loading on resins using source water ranged from 1.47 to 1.70 µg/g with the corresponding Kd values from 189.9 to 227.0 mL/g. The sorption values when the iodine is converted to iodide ranged from 2.75 to 5.90 µg/g with the corresponding Kd values from 536.3 to 2979.6 mL/g. It is recommended that methods to convert iodine to iodide be investigated in fiscal year (FY) 2015. The chemicals used to convert iodine to iodate adversely affected the sorption of iodine onto the carbon materials. Using as-received source water, loading and Kd values ranged from 1.47 to 1.70 µg/g and 189.8 to 226.3 mL/g respectively. After treatment, loading and Kd values could not be calculated because there was little change between the initial and final iodine concentration. It is recommended the cause of the decrease in iodine sorption be investigated in FY15. In direct support of CH2M HILL Plateau Remediation Company, Pacific Northwest National Laboratory has evaluated samples from within the 200W pump and treat bioreactors. As part of this analysis, pictures taken within the bioreactor reveal a precipitate that, based on physical properties and known aqueous chemistry, is hypothesized to be iron pyrite or chalcopyrite, which could affect iodine adsorption. It is recommended these materials be tested at different solution-to-solid ratios in FY15 to determine their effect on iodine

  20. Iodine adsorption on ion-exchange resins and activated carbons: batch testing

    International Nuclear Information System (INIS)

    Parker, Kent E.; Golovich, Elizabeth C.; Wellman, Dawn M.

    2014-01-01

    Iodine sorption onto seven resins and six carbon materials was evaluated using water from well 299-W19-36 on the Hanford Site. These materials were tested using a range of solution-to-solid ratios. The test results are as follows. The efficacy of the resin and granular activated carbon materials was less than predicted based on manufacturers' performance data. It is hypothesized that this is due to the differences in speciation previously determined for Hanford groundwater. The sorption of iodine is affected by the iodine species in the source water. Iodine loading on resins using source water ranged from 1.47 to 1.70 µg/g with the corresponding K d values from 189.9 to 227.0 mL/g. The sorption values when the iodine is converted to iodide ranged from 2.75 to 5.90 µg/g with the corresponding K d values from 536.3 to 2979.6 mL/g. It is recommended that methods to convert iodine to iodide be investigated in fiscal year (FY) 2015. The chemicals used to convert iodine to iodate adversely affected the sorption of iodine onto the carbon materials. Using as-received source water, loading and K d values ranged from 1.47 to 1.70 µg/g and 189.8 to 226.3 mL/g respectively. After treatment, loading and K d values could not be calculated because there was little change between the initial and final iodine concentration. It is recommended the cause of the decrease in iodine sorption be investigated in FY15. In direct support of CH2M HILL Plateau Remediation Company, Pacific Northwest National Laboratory has evaluated samples from within the 200W pump and treat bioreactors. As part of this analysis, pictures taken within the bioreactor reveal a precipitate that, based on physical properties and known aqueous chemistry, is hypothesized to be iron pyrite or chalcopyrite, which could affect iodine adsorption. It is recommended these materials be tested at different solution-to-solid ratios in FY15 to determine their effect on iodine sorption.

  1. Promoting Physical Activity in Low-Active Adolescents via Facebook: A Pilot Randomized Controlled Trial to Test Feasibility.

    Science.gov (United States)

    Wójcicki, Thomas R; Grigsby-Toussaint, Diana; Hillman, Charles H; Huhman, Marian; McAuley, Edward

    2014-10-30

    The World Wide Web is an effective method for delivering health behavior programs, yet major limitations remain (eg, cost of development, time and resource requirements, limited interactivity). Social media, however, has the potential to deliver highly customizable and socially interactive behavioral interventions with fewer constraints. Thus, the evaluation of social media as a means to influence health behaviors is warranted. The objective of this trial was to examine and demonstrate the feasibility of using an established social networking platform (ie, Facebook) to deliver an 8 week physical activity intervention to a sample of low-active adolescents (N=21; estimated marginal mean age 13.48 years). Participants were randomized to either an experimental (ie, Behavioral) or attentional control (ie, Informational) condition. Both conditions received access to a restricted-access, study-specific Facebook group where the group's administrator made two daily wall posts containing youth-based physical activity information and resources. Primary outcomes included physical activity as assessed by accelerometry and self-report. Interactions and main effects were examined, as well as mean differences in effect sizes. Analyses revealed significant improvements over time on subjectively reported weekly leisure-time physical activity (F1,18=8.426, P=.009, η2 = .319). However, there was no interaction between time and condition (F1,18=0.002, P=.968, η2 = .000). There were no significant time or interaction effects among the objectively measured physical activity variables. Examination of effect sizes revealed moderate-to-large changes in physical activity outcomes. Results provide initial support for the feasibility of delivery of a physical activity intervention to low-active adolescents via social media. Whether by employing behavioral interventions via social media can result in statistically meaningful changes in health-related behaviors and outcomes remains to be

  2. The Physical Activity Scale for Individuals with Physical Disabilities: test-retest reliability and comparison with an accelerometer.

    Science.gov (United States)

    van der Ploeg, Hidde P; Streppel, Kitty R M; van der Beek, Allard J; van der Woude, Luc H V; Vollenbroek-Hutten, Miriam; van Mechelen, Willem

    2007-01-01

    The objective was to determine the test-retest reliability and criterion validity of the Physical Activity Scale for Individuals with Physical Disabilities (PASIPD). Forty-five non-wheelchair dependent subjects were recruited from three Dutch rehabilitation centers. Subjects' diagnoses were: stroke, spinal cord injury, whiplash, and neurological-, orthopedic- or back disorders. The PASIPD is a 7-d recall physical activity questionnaire that was completed twice, 1 wk apart. During this week, physical activity was also measured with an Actigraph accelerometer. The test-retest reliability Spearman correlation of the PASIPD was 0.77. The criterion validity Spearman correlation was 0.30 when compared to the accelerometer. The PASIPD had test-retest reliability and criterion validity that is comparable to well established self-report physical activity questionnaires from the general population.

  3. Early postoperative erythromycin breath test correlates with hepatic cytochrome P4503A activity in liver transplant recipients

    DEFF Research Database (Denmark)

    Schmidt, L E; Olsen, A K; Stentoft, K

    2001-01-01

    BACKGROUND: Interindividual variation in the pharmacokinetics of the immunosuppressive agents cyclosporine (INN, ciclosporin) and tacrolimus may result from differences in the activity of cytochrome P4503A (CYP3A). The erythromycin breath test is an in vivo assay of hepatic CYP3A activity......, but the method has never been directly validated. The aim of the study was to investigate whether an early postoperative erythromycin breath test correlated with the hepatic CYP3A protein level and catalytic activity in liver transplant recipients. METHODS: In 18 liver transplant recipients, the erythromycin...... breath test was performed within 2 hours after transplantation. A graft biopsy was obtained during surgery and analyzed for the CYP3A protein level by Western blotting and for CYP3A activity with erythromycin demethylation and testosterone 6beta- hydroxylation assays. RESULTS: The erythromycin breath...

  4. A review of two recent occurrences at the Advanced Test Reactor involving subcontractor activities

    International Nuclear Information System (INIS)

    Dahlke, H.J.; Jensen, N.C.; Vail, J.A.

    1997-11-01

    This report documents the results of a brief, unofficial investigation into two incidents at the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Test Reactor (ATR) facility, reported on October 25 and 31, 1997. The first event was an unanticipated breach of confinement. The second involved reactor operation with an inoperable seismic scram subsystem, violating the reactor's Technical Specifications. These two incidents have been found to be unrelated. A third event that occurred on December 16, 1996, is also discussed because of its similarities to the first event listed above. Both of these incidents were unanticipated breaches of confinement, and both involved the work of construction subcontractor personnel. The cause for the subcontractor related occurrences is a work control process that fails to effectively interface with LMITCO management. ATR Construction Project managers work sufficient close with construction subcontractor personnel to understand planned day-to-day activities. They also have sufficient training and understanding of reactor operations to ensure adherence to applicable administrative requirements. However, they may not be sufficiently involved in the work authorization and control process to bridge an apparent communications gap between subcontractor employees and Facility Operations/functional support personnel for work inside the reactor facility. The cause for the inoperable seismic scram switch (resulting from a disconnected lead) is still under investigation. It does not appear to be subcontractor related

  5. A longitudinal investigation of older adults' physical activity: Testing an integrated dual-process model.

    Science.gov (United States)

    Arnautovska, Urska; Fleig, Lena; O'Callaghan, Frances; Hamilton, Kyra

    2017-02-01

    To assess the effects of conscious and non-conscious processes for prediction of older adults' physical activity (PA), we tested a dual-process model that integrated motivational (behavioural intention) and volitional (action planning and coping planning) processes with non-conscious, automatic processes (habit). Participants (N = 215) comprised community-dwelling older adults (M = 73.8 years). A longitudinal design was adopted to investigate direct and indirect effects of intentions, habit strength (Time 1), and action planning and coping planning (Time 2) on PA behaviour (Time 3). Structural equation modelling was used to evaluate the model. The model provided a good fit to the data, accounting for 44% of the variance in PA behaviour at Time 3. PA was predicted by intentions, action planning, and habit strength, with action planning mediating the intention-behaviour relationship. An effect of sex was also found where males used fewer planning strategies and engaged in more PA than females. By investigating an integration of conscious and non-conscious processes, this study provides a novel understanding of older adults' PA. Interventions aiming to promote PA behaviour of older adults should target the combination of psychological processes.

  6. Characterisation of aroma profiles of commercial soy sauce by odour activity value and omission test.

    Science.gov (United States)

    Feng, Yunzi; Su, Guowan; Zhao, Haifeng; Cai, Yu; Cui, Chun; Sun-Waterhouse, Dongxiao; Zhao, Mouming

    2015-01-15

    Twenty-seven commercial soy sauces produced through three different fermentation processes (high-salt liquid-state fermentation soy sauce, HLFSS; low-salt solid-state fermentation soy sauce, LSFSS; Koikuchi soy sauce, KSS) were examined to identify the aroma compounds and the effect of fermentation process on the flavour of the soy sauce was investigated. Results showed that 129 volatiles were identified, of which 41 aroma-active components were quantified. The types of odorants occurring in the three soy sauce groups were similar, although their intensities significantly differed. Many esters and phenols were found at relatively high intensities in KSS, whereas some volatile acids only occurred in LSFSS. Furthermore, 23 aroma compounds had average OAVs>1, among which 3-methylbutanal, ethyl acetate, 4-hydroxy-2-ethyl-5-methyl-3(2H)-furanone, 2-methylbutanal and 3-(methylthio)propanal exhibited the highest average OAVs (>100). In addition, omission tests verified the important contribution of the products resulting from amino acid catabolism to the characteristic aroma of soy sauce. Copyright © 2014. Published by Elsevier Ltd.

  7. Test Plan for Measuring Ventilation Rates and Combustible Gas Levels in TWRS Active Catch Tanks

    Energy Technology Data Exchange (ETDEWEB)

    NGUYEN, D.M.

    1999-10-25

    The purpose of this sampling activity is to obtain data to support an initial evaluation of potential hazards due to the presence of combustible gas in catch tanks that are currently operated by the River Protection Project (RPP). Results of the hazard analysis will be used to support closure of the flammable gas unreviewed safety question for these facilities. The data collection will be conducted in accordance with the Tank Safety Screening Data Quality Objective (Dukelow et al. 1995). Combustible gas, ammonia, and organic vapor levels in the headspace of the catch tanks will be field-measured using hand-held instruments. If a combustible gas level measurement in a tank exceeds an established threshold, gas samples will he collected in SUMMA' canisters for more extensive laboratory analysis. In addition, ventilation rates of some catch tanks will be measured to evaluate removal of flammable gas by air flowing through the tanks. This test plan identifies the sample collection, laboratory analysis, quality assurance, and reporting objectives for this data collection effort. The plan also provides the procedures for field measurement of combustible gas concentrations and ventilation rates.

  8. Underground Test Area Activity Quality Assurance Plan Nevada National Security Site, Nevada. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Krenzien, Susan [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States); Farnham, Irene [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States)

    2015-06-01

    This Quality Assurance Plan (QAP) provides the overall quality assurance (QA) requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) activities. The requirements in this QAP are consistent with DOE Order 414.1D, Change 1, Quality Assurance (DOE, 2013a); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). If a participant’s requirement document differs from this QAP, the stricter requirement will take precedence. NNSA/NFO, or designee, must review this QAP every two years. Changes that do not affect the overall scope or requirements will not require an immediate QAP revision but will be incorporated into the next revision cycle after identification. Section 1.0 describes UGTA objectives, participant responsibilities, and administrative and management quality requirements (i.e., training, records, procurement). Section 1.0 also details data management and computer software requirements. Section 2.0 establishes the requirements to ensure newly collected data are valid, existing data uses are appropriate, and environmental-modeling methods are reliable. Section 3.0 provides feedback loops through assessments and reports to management. Section 4.0 provides the framework for corrective actions. Section 5.0 provides references for this document.

  9. Benchmark of the SixTrack-Fluka Active Coupling Against the SPS Scrapers Burst Test

    CERN Multimedia

    Mereghetti, A; Cerutti, F

    2014-01-01

    The SPS scrapers are a key ingredient for the clean injection into the LHC: they cut off halo particles quite close to the beam core (e.g.~3.5 sigma) just before extraction, to minimise the risk for quenches. The improved beam parameters as envisaged by the LHC Injectors Upgrade (LIU) Project required a revision of the present system, to assess its suitability and robustness. In particular, a burst (i.e. endurance) test of the scraper blades has been carried out, with the whole bunch train being scraped at the centre (worst working conditions). In order to take into account the effect of betatron and longitudinal beam dynamics on energy deposition patterns, and nuclear and Coulomb scattering in the absorbing medium onto loss patterns, the SixTrack and Fluka codes have been coupled, profiting from the best of the refined physical models they respectively embed. The coupling envisages an active exchange of tracked particles between the two codes at each turn, and an on-line aperture check in SixTrack, in order ...

  10. Using observations of slipping velocities to test the hypothesis that reconnection heats the active region corona

    Science.gov (United States)

    Yang, Kai; Longcope, Dana; Guo, Yang; Ding, Mingde

    2017-08-01

    Numerous proposed coronal heating mechanisms have invoked magnetic reconnection in some role. Testing such a mechanism requires a method of measuring magnetic reconnection coupled with a prediction of the heat delivered by reconnection at the observed rate. In the absence of coronal reconnection, field line footpoints move at the same velocity as the plasma they find themselves in. The rate of coronal reconnection is therefore related to any discrepancy observed between footpoint motion and that of the local plasma — so-called slipping motion. We propose a novel method to measure this velocity discrepancy by combining a sequence of non-linear force-free field extrapolations with maps of photospheric velocity. We obtain both from a sequence of vector magnetograms of an active region (AR). We then propose a method of computing the coronal heating produced under the assumption the observed slipping velocity was due entirely to coronal reconnection. This heating rate is used to predict density and temperature at points along an equilibrium loop. This, in turn, is used to synthesize emission in EUV and SXR bands. We perform this analysis using a sequence of HMI vector magnetograms of a particular AR and compare synthesized images to observations of the same AR made by SDO. We also compare differential emission measure inferred from those observations to that of the modeled corona.

  11. Underground Test Area Activity Quality Assurance Plan Nevada National Security Site, Nevada. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States); Krenzien, Susan [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States)

    2012-10-01

    This Quality Assurance Plan (QAP) provides the overall quality assurance (QA) requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) activities. The requirements in this QAP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). NNSA/NSO, or designee, must review this QAP every two years. Changes that do not affect the overall scope or requirements will not require an immediate QAP revision but will be incorporated into the next revision cycle after identification. Section 1.0 describes UGTA objectives, participant responsibilities, and administrative and management quality requirements (i.e., training, records, procurement). Section 1.0 also details data management and computer software requirements. Section 2.0 establishes the requirements to ensure newly collected data are valid, existing data uses are appropriate, and environmental-modeling methods are reliable. Section 3.0 provides feedback loops through assessments and reports to management. Section 4.0 provides the framework for corrective actions. Section 5.0 provides references for this document.

  12. Underground Test Area Activity Preemptive Review Guidance Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro, Las Vegas, NV (United States); Rehfeldt, Kenneth [Navarro, Las Vegas, NV (United States)

    2016-10-01

    Preemptive reviews (PERs) of Underground Test Area (UGTA) Activity corrective action unit (CAU) studies are an important and long-maintained quality improvement process. The CAU-specific PER committees provide internal technical review of ongoing work throughout the CAU lifecycle. The reviews, identified in the UGTA Quality Assurance Plan (QAP) (Sections 1.3.5.1 and 3.2), assure work is comprehensive, accurate, in keeping with the state of the art, and consistent with CAU goals. PER committees review various products, including data, documents, software/codes, analyses, and models. PER committees may also review technical briefings including Federal Facility Agreement and Consent Order (FFACO)-required presentations to the Nevada Division of Environmental Protection (NDEP) and presentations supporting key technical decisions (e.g., investigation plans and approaches). PER committees provide technical recommendations to support regulatory decisions that are the responsibility of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) and NDEP.

  13. Activity of human hippocampal formation and amygdala neurons during memory testing.

    Science.gov (United States)

    Halgren, E; Babb, T L; Crandall, P H

    1978-11-01

    Single and multiple unit recordings were made from fine wires stereotaxically implanted in the hippocampus (HC), hippocampal gyrus (HCG), and amygdala (Am) of psychomotor epileptics. During a series of memory and control tests presented on slides, 21 of 155 HCG units, 15 of 59 HC units, and 2 of 54 Am units showed what appeared to be simple phasic or tonic visual responses. Twenty-seven other units, found only in the HCG, changed firing only during slides requiring a choice ('choice units'). A given choice unit responded during choices indicated verbally or manually, and during tasks requiring recall of Recent Memory, various visual discriminations, and expressions of preference. Choice units were not affected by sensory stimulation or motor activity in contexts not requiring choice. Phasically inhibited choice units had higher firing rates and lower signal-to-noise ratios than tonically excited units. Whether an electrode recorded a choice unit was unrelated to if it recorded a response to hyperventilation, or was in an area of epileptic pathology. Recordings were also made during an interview lasting several hours and eliciting a wide range of behaviors. Five of the 131 HCG units fired in repeated extended bursts, at least 50 times background during recall of word pairs or of the patient's hospital room. The unit response did not occur during numerous control tasks possessing similar overt sensory, motor, and social concomitants, but not requiring Recent Memory.

  14. Coalbed natural gas exploration, drilling activities, and geologic test results, 2007-2010

    Science.gov (United States)

    Clark, Arthur C.

    2014-01-01

    The U.S. Geological Survey, in partnership with the U.S. Bureau of Land Management, the North Slope Borough, and the Arctic Slope Regional Corporation conducted a four-year study designed to identify, define, and delineate a shallow coalbed natural gas (CBNG) resource with the potential to provide locally produced, affordable power to the community of Wainwright, Alaska. From 2007 through 2010, drilling and testing activities conducted at three sites in or near Wainwright, identified and evaluated an approximately 7.5-ft-thick, laterally continuous coalbed that contained significant quantities of CBNG. This coalbed, subsequently named the Wainwright coalbed, was penetrated at depths ranging from 1,167 ft to 1,300 ft below land surface. Core samples were collected from the Wainwright coalbed at all three drill locations and desorbed-gas measurements were taken from seventeen 1-ft-thick sections of the core. These measurements indicate that the Wainwright coalbed contains enough CBNG to serve as a long-term energy supply for the community. Although attempts to produce viable quantities of CBNG from the Wainwright coalbed proved unsuccessful, it seems likely that with proper well-field design and by utilizing currently available drilling and reservoir stimulation techniques, this CBNG resource could be developed as a long-term economically viable energy source for Wainwright.

  15. A data base and a standard material for use in acceptance testing of low-activity waste products

    International Nuclear Information System (INIS)

    Wolf, S.F.; Ebert, W.L.; Luo, J.S.; Strachan, D.M.

    1998-04-01

    The authors have conducted replicate dissolution tests following the product consistency test (PCT) procedure to measure the mean and standard deviation of the solution concentrations of B, Na, and Si at various combinations of temperature, duration, and glass/water mass ratio. Tests were conducted with a glass formulated to be compositionally similar to low-activity waste products anticipated for Hanford to evaluate the adequacy of test methods that have been designated in privatization contracts for use in product acceptance. An important finding from this set of tests is that the solution concentrations generated in tests at 20 C will likely be too low to measure the dissolution rates of waste products reliably. Based on these results, the authors recommend that the acceptance test be conducted at 40 C. Tests at 40 C generated higher solution concentrations, were more easily conducted, and the measured rates were easily related to those at 20 C. Replicate measurements of other glass properties were made to evaluate the possible use of LRM-1 as a standard material. These include its composition, homogeneity, density, compressive strength, the Na leachability index with the ANSI/ANS 16.1 leach test, and if the glass is characteristically hazardous with the toxicity characteristic leach procedure. The values of these properties were within the acceptable limits identified for Hanford low-activity waste products. The reproducibility of replicate tests and analyses indicates that the glass would be a suitable standard material

  16. Evaluation of the single-pass flow-through test to support a low-activity waste specification

    International Nuclear Information System (INIS)

    McGrail, B.P.; Peeler, D.K.

    1995-09-01

    A series of single-pass flow-through (SPFT) tests was performed on five reference low-activity waste glasses and a reference glass from the National Institute of Standards and Technology to support a product specification for low-activity waste (LAW) forms. The results showed that the SPFT test provides a means to quantitatively distinguish among LAW glass forms in terms of their forward reaction rate at a given temperature and solution pH. Two of the test glasses were also subjected to SPFT testing at Argonne National Laboratory (ANL). Forward reaction rate constants calculated from the ANL test data were 100 to over 1,000 times larger than the values obtained from the SPFT tests conducted at PNL. An analysis of the ANL results showed that they were inconsistent with independent measurements done on glasses of similar composition, the known pH-dependence of the forward rate, and with the results from low surface-area-to-volume, short duration product consistency tests. Because the data set obtained from the SPFT tests done at PNL was consistent with each of these same factors, a detailed examination of the test procedures used at both laboratories was performed to determine the cause(s) of the discrepancy. The omission of background subtraction in the data analysis procedure and the short-duration (on the order of hours) of the ANL tests are factors that may have significantly affected the calculated rates

  17. VALIDATION REPORT (PHASE 2) FOR THE FISH SEXUAL DEVELOPMENT TEST FOR THE DETECTION OF ENDOCRINE ACTIVE SUBSTANCES

    DEFF Research Database (Denmark)

    Holbech, Henrik; Kinnberg, Karin Lund; Petersen, Gitte

    This document presents the validation report (phase 2) of the Fish Sexual Development Test (FSDT). The Fish Sexual Development Test (FSDT) covers a life-stage where sexual development is particularly sensitive to perturbation caused by endocrine active chemicals. The chemical exposure lasts...... Guideline on the fish sexual development test to the Working Group of the National Coordinators of the Test Guidelines Programme (WNT). The project was included on the Test Guidelines workplan in 2003, and extensive validation of the test method was carried out until 2009. Two validation studies were...... for about 60 days, at the end of which endpoints of ecological relevance like the sex ratio of the exposed fish is calculated and the biomarker endpoint vitellogenin is measured in individual animals. In 2003, Denmark, on behalf of the European Nordic countries, proposed a new project o develop a Test...

  18. A leukocyte activation test identifies food items which induce release of DNA by innate immune peripheral blood leucocytes.

    Science.gov (United States)

    Garcia-Martinez, Irma; Weiss, Theresa R; Yousaf, Muhammad N; Ali, Ather; Mehal, Wajahat Z

    2018-01-01

    Leukocyte activation (LA) testing identifies food items that induce a patient specific cellular response in the immune system, and has recently been shown in a randomized double blinded prospective study to reduce symptoms in patients with irritable bowel syndrome (IBS). We hypothesized that test reactivity to particular food items, and the systemic immune response initiated by these food items, is due to the release of cellular DNA from blood immune cells. We tested this by quantifying total DNA concentration in the cellular supernatant of immune cells exposed to positive and negative foods from 20 healthy volunteers. To establish if the DNA release by positive samples is a specific phenomenon, we quantified myeloperoxidase (MPO) in cellular supernatants. We further assessed if a particular immune cell population (neutrophils, eosinophils, and basophils) was activated by the positive food items by flow cytometry analysis. To identify the signaling pathways that are required for DNA release we tested if specific inhibitors of key signaling pathways could block DNA release. Foods with a positive LA test result gave a higher supernatant DNA content when compared to foods with a negative result. This was specific as MPO levels were not increased by foods with a positive LA test. Protein kinase C (PKC) inhibitors resulted in inhibition of positive food stimulated DNA release. Positive foods resulted in CD63 levels greater than negative foods in eosinophils in 76.5% of tests. LA test identifies food items that result in release of DNA and activation of peripheral blood innate immune cells in a PKC dependent manner, suggesting that this LA test identifies food items that result in release of inflammatory markers and activation of innate immune cells. This may be the basis for the improvement in symptoms in IBS patients who followed an LA test guided diet.

  19. Characterization of Peripheral Activity States and Cortical Local Field Potentials of Mice in an Elevated Plus Maze Test.

    Science.gov (United States)

    Okonogi, Toya; Nakayama, Ryota; Sasaki, Takuya; Ikegaya, Yuji

    2018-01-01

    Elevated plus maze (EPM) tests have been used to assess animal anxiety levels. Little information is known regarding how physiological activity patterns of the brain-body system are altered during EPM tests. Herein, we monitored cortical local field potentials (LFPs), electrocardiograms (ECGs), electromyograms (EMGs), and respiratory signals in individual mice that were repeatedly exposed to EPM tests. On average, mouse heart rates were higher in open arms. In closed arms, the mice occasionally showed decreased heart and respiratory rates lasting for several seconds or minutes, characterized as low-peripheral activity states of peripheral signals. The low-activity states were observed only when the animals were in closed arms, and the frequencies of the states increased as the testing days proceeded. During the low-activity states, the delta and theta powers of cortical LFPs were significantly increased and decreased, respectively. These results demonstrate that cortical oscillations crucially depend on whether an animal exhibits low-activity states in peripheral organs rather than the EPM arm in which the animal is located. These results suggest that combining behavioral tests with physiological makers enables a more accurate evaluation of rodent mental states.

  20. Characterization of Peripheral Activity States and Cortical Local Field Potentials of Mice in an Elevated Plus Maze Test

    Directory of Open Access Journals (Sweden)

    Toya Okonogi

    2018-04-01

    Full Text Available Elevated plus maze (EPM tests have been used to assess animal anxiety levels. Little information is known regarding how physiological activity patterns of the brain-body system are altered during EPM tests. Herein, we monitored cortical local field potentials (LFPs, electrocardiograms (ECGs, electromyograms (EMGs, and respiratory signals in individual mice that were repeatedly exposed to EPM tests. On average, mouse heart rates were higher in open arms. In closed arms, the mice occasionally showed decreased heart and respiratory rates lasting for several seconds or minutes, characterized as low-peripheral activity states of peripheral signals. The low-activity states were observed only when the animals were in closed arms, and the frequencies of the states increased as the testing days proceeded. During the low-activity states, the delta and theta powers of cortical LFPs were significantly increased and decreased, respectively. These results demonstrate that cortical oscillations crucially depend on whether an animal exhibits low-activity states in peripheral organs rather than the EPM arm in which the animal is located. These results suggest that combining behavioral tests with physiological makers enables a more accurate evaluation of rodent mental states.

  1. An Alternative to the Human Hemoglobin Test in the Investigation of Bloodstains Treated with Active Oxygen: The Human Glycophorin A Test

    Directory of Open Access Journals (Sweden)

    Ana Castelló

    2011-01-01

    Full Text Available In criminal investigations, there are three stages involved when studying bloodstains: search and orientation, confirmation, and individualization. Confirmatory tests have two aims: to show that the stain contains a human biological fluid and to confirm the type of biological fluid. The need to determine the nature of the evidence is reflected in the latest bibliography, where the possibility of employing mRNA and miRNA markers for this purpose is proposed. While these new proposals are being investigated, the kits for determining human hemoglobin currently provide a simple solution for resolving this issue. With these kits, the possibility of obtaining false positives and false negatives is well known. However, recently, a new problem has been detected. This involves the interference caused by new cleaning products that contain sodium percarbonate (or active oxygen when determining human hemoglobin. With the aim to resolve this problem, this work studied the ability of the human glycophorin A test to determine human blood in samples that have been treated with active oxygen. Our results show that the human glycophorin A test has a greater resistance to the destructive effect of the new detergents containing active oxygen; consequently, it provides an alternative to be taken into consideration in the confirmatory diagnoses of bloodstains.

  2. Fluidized bed steam reformed mineral waste form performance testing to support Hanford Supplemental Low Activity Waste Immobilization Technology Selection

    Energy Technology Data Exchange (ETDEWEB)

    Jantzen, C. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Pierce, E. M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bannochie, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Burket, P. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Cozzi, A. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Crawford, C. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Daniel, W. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Herman, C. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Miller, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Missimer, D. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nash, C. A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Williams, M. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Brown, C. F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Qafoku, N. P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Neeway, J. J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Valenta, M. M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gill, G. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Swanberg, D. J. [Washington River Protection Solutions (WRPS), Richland, WA (United States); Robbins, R. A. [Washington River Protection Solutions (WRPS), Richland, WA (United States); Thompson, L. E. [Washington River Protection Solutions (WRPS), Richland, WA (United States)

    2015-10-01

    This report describes the benchscale testing with simulant and radioactive Hanford Tank Blends, mineral product characterization and testing, and monolith testing and characterization. These projects were funded by DOE EM-31 Technology Development & Deployment (TDD) Program Technical Task Plan WP-5.2.1-2010-001 and are entitled “Fluidized Bed Steam Reformer Low-Level Waste Form Qualification”, Inter-Entity Work Order (IEWO) M0SRV00054 with Washington River Protection Solutions (WRPS) entitled “Fluidized Bed Steam Reforming Treatability Studies Using Savannah River Site (SRS) Low Activity Waste and Hanford Low Activity Waste Tank Samples”, and IEWO M0SRV00080, “Fluidized Bed Steam Reforming Waste Form Qualification Testing Using SRS Low Activity Waste and Hanford Low Activity Waste Tank Samples”. This was a multi-organizational program that included Savannah River National Laboratory (SRNL), THOR® Treatment Technologies (TTT), Pacific Northwest National Laboratory (PNNL), Oak Ridge National Laboratory (ORNL), Office of River Protection (ORP), and Washington River Protection Solutions (WRPS). The SRNL testing of the non-radioactive pilot-scale Fluidized Bed Steam Reformer (FBSR) products made by TTT, subsequent SRNL monolith formulation and testing and studies of these products, and SRNL Waste Treatment Plant Secondary Waste (WTP-SW) radioactive campaign were funded by DOE Advanced Remediation Technologies (ART) Phase 2 Project in connection with a Work-For-Others (WFO) between SRNL and TTT.

  3. Supplemental Immobilization of Hanford Low-Activity Waste: Cast Stone Screening Tests

    Energy Technology Data Exchange (ETDEWEB)

    Westsik, Joseph H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lindberg, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Heasler, Patrick G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mercier, Theresa M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Russell, Renee L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cozzi, Alex [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Daniel, William E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Eibling, Russell E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hansen, E. K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Reigel, Marissa M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Swanberg, David J. [Washington River Protection Solutions (WRPS), Aiken, SC (United States)

    2013-09-30

    More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is being constructed to treat the wastes and immobilize them in a glass waste form. The WTP includes a pretreatment facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the nonradioactive chemicals. The HLW will be converted to glass in the HLW vitrification facility for ultimate disposal at an offsite federal repository. At least a portion (~35%) of the LAW will be converted to glass in the LAW vitrification facility and will be disposed of onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize the wastes destined for each facility. However, a second LAW immobilization facility will be needed for the expected volume of LAW requiring immobilization. A cementitious waste form known as Cast Stone is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with the waste acceptance criteria for the disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. Further, the waste form must be tested to provide the technical basis for understanding the long-term performance of the waste form in the disposal environment. These waste form performance data are needed to support risk assessment and performance assessment (PA) analyses of the long-term environmental impact of the waste disposal in the IDF

  4. The Test Case of HD 26965: Difficulties Disentangling Weak Doppler Signals from Stellar Activity

    Science.gov (United States)

    Díaz, Matías R.; Jenkins, James S.; Tuomi, Mikko; Butler, R. Paul; Soto, Maritza G.; Teske, Johanna K.; Feng, Fabo; Shectman, Stephen A.; Arriagada, Pamela; Crane, Jeffrey D.; Thompson, Ian B.; Vogt, Steven S.

    2018-03-01

    We report the discovery of a radial velocity signal that can be interpreted as a planetary-mass candidate orbiting the K dwarf HD 26965, with an orbital period of 42.364 ± 0.015 days, or alternatively, as the presence of residual, uncorrected rotational activity in the data. Observations include data from HIRES, PFS, CHIRON, and HARPS, where 1111 measurements were made over 16 years. Our best solution for HD 26965 b is consistent with a super-Earth that has a minimum mass of 6.92 ± 0.79 {M}\\oplus orbiting at a distance of 0.215 ± 0.008 au from its host star. We have analyzed the correlation between spectral activity indicators and the radial velocities from each instrument, showing moderate correlations that we include in our model. From this analysis, we recover a ∼38-day signal, which matches some literature values of the stellar rotation period. However, from independent Mt. Wilson HK data for this star, we find evidence for a significant 42-day signal after subtraction of longer period magnetic cycles, casting doubt on the planetary hypothesis for this period. Although our statistical model strongly suggests that the 42-day signal is Doppler in origin, we conclude that the residual effects of stellar rotation are difficult to fully model and remove from this data set, highlighting the difficulties to disentangle small planetary signals and photospheric noise, particularly when the orbital periods are close to the rotation period of the star. This study serves as an excellent test case for future works that aim to detect small planets orbiting “Sun-like” stars using radial velocity measurements. Some of the data presented herein were obtained at the W.M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space Administration. The Observatory was made possible by the generous financial support of the W.M. Keck Foundation.

  5. Testing a self-determination theory model of children's physical activity motivation: a cross-sectional study.

    Science.gov (United States)

    Sebire, Simon J; Jago, Russell; Fox, Kenneth R; Edwards, Mark J; Thompson, Janice L

    2013-09-26

    Understanding children's physical activity motivation, its antecedents and associations with behavior is important and can be advanced by using self-determination theory. However, research among youth is largely restricted to adolescents and studies of motivation within certain contexts (e.g., physical education). There are no measures of self-determination theory constructs (physical activity motivation or psychological need satisfaction) for use among children and no previous studies have tested a self-determination theory-based model of children's physical activity motivation. The purpose of this study was to test the reliability and validity of scores derived from scales adapted to measure self-determination theory constructs among children and test a motivational model predicting accelerometer-derived physical activity. Cross-sectional data from 462 children aged 7 to 11 years from 20 primary schools in Bristol, UK were analysed. Confirmatory factor analysis was used to examine the construct validity of adapted behavioral regulation and psychological need satisfaction scales. Structural equation modelling was used to test cross-sectional associations between psychological need satisfaction, motivation types and physical activity assessed by accelerometer. The construct validity and reliability of the motivation and psychological need satisfaction measures were supported. Structural equation modelling provided evidence for a motivational model in which psychological need satisfaction was positively associated with intrinsic and identified motivation types and intrinsic motivation was positively associated with children's minutes in moderate-to-vigorous physical activity. The study provides evidence for the psychometric properties of measures of motivation aligned with self-determination theory among children. Children's motivation that is based on enjoyment and inherent satisfaction of physical activity is associated with their objectively-assessed physical

  6. Testing a self-determination theory model of children’s physical activity motivation: a cross-sectional study

    Science.gov (United States)

    2013-01-01

    Background Understanding children’s physical activity motivation, its antecedents and associations with behavior is important and can be advanced by using self-determination theory. However, research among youth is largely restricted to adolescents and studies of motivation within certain contexts (e.g., physical education). There are no measures of self-determination theory constructs (physical activity motivation or psychological need satisfaction) for use among children and no previous studies have tested a self-determination theory-based model of children’s physical activity motivation. The purpose of this study was to test the reliability and validity of scores derived from scales adapted to measure self-determination theory constructs among children and test a motivational model predicting accelerometer-derived physical activity. Methods Cross-sectional data from 462 children aged 7 to 11 years from 20 primary schools in Bristol, UK were analysed. Confirmatory factor analysis was used to examine the construct validity of adapted behavioral regulation and psychological need satisfaction scales. Structural equation modelling was used to test cross-sectional associations between psychological need satisfaction, motivation types and physical activity assessed by accelerometer. Results The construct validity and reliability of the motivation and psychological need satisfaction measures were supported. Structural equation modelling provided evidence for a motivational model in which psychological need satisfaction was positively associated with intrinsic and identified motivation types and intrinsic motivation was positively associated with children’s minutes in moderate-to-vigorous physical activity. Conclusions The study provides evidence for the psychometric properties of measures of motivation aligned with self-determination theory among children. Children’s motivation that is based on enjoyment and inherent satisfaction of physical activity is

  7. Comparison tests, in a pilot plant, of the performance of a coal-derived granular activated carbon: a comparison with coconut husk derived activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, S.; Kasahara, A.; Tsuruzono, Y.; Gotoh, M.

    1986-01-01

    A 160 m/sup 3//d pilot plant has been used in a series of comparison tests of the performance of coal-derived and coconut husk derived activated carbons. Activated carbons are used to remove trihalomethane precursors and malodorous substances from city water. A higher mean removal of coloration and COD/sub M//sub n/ was achieved with the coal-derived carbon (by factors of 1.5 and 1.8, respectively). The two activated carbons gave similar performances as regards turbidity, alkalinity, total iron and total manganese. 4 figures, 5 tables.

  8. Dynamics of changes in the activation of blood coagulation tests at different variants of thromboprophylaxis

    Directory of Open Access Journals (Sweden)

    Олена Миколаївна Клигуненко

    2015-09-01

    Full Text Available Aim: To study an influence of the different variants of thromboprophylaxis on activation of blood coagulation test on the background of surgical aggression. D-dimer concentration in serum is in direct proportion to fibrinolysis activity and to an amount of lysed fibrin. At the same time fibrinolysis activation is followed with an increase of formation of products of fibrin degradation (PFD that interact with fibrin-monomers and increase the number of SFMC.Materials and methods: After informed consent 200 patients were prospectively divided into groups depending on preparation and regimen of thromboprophylaxis. 1 group (n=30 – ungraded heparin (UGH (5000 ОD for 2 hours before surgery 2 times during 7 days after it. 2 group(n=30 nadraparin calcium 9500 anti-Ха МO (0,3 ml for 2 hours before surgery 2500 МО 1 time for a day 7 days after surgery; 3 group(n=48 – endoxaparin sodium(0,2 ml for 2 hours before surgery 1 time a day 7 days; 4 group(n=29 endoxaparin sodium(0,2ml for 8 hours before surgery, 0,2 ml 1 time a day 7 days; 5 group(n=34 – bemiparin sodium(0,2 ml for 2 hours before surgery 0,2 ml 1 time a day 7 days; 6 group(n=29 bemiparin sodium(0,2ml in 6 hours after surgery 1 time a day 7 days. Patients were comparable on sex, concomitant pathology, class АSA (1-2 and type of surgical intervention. There were studied the number of thrombocytes, prothrombin time (PT, INR AFTT, fibrinogen, Х-а factor activity, antithrombin, 111 (AT111, protein C, SFMC, d-dimer before surgery, on 1,5 and 7 day after it.Results and discussions: On the 1 day of postsurgical period the most influence on D-dimer level had presurgical thromboprophylaxis (TPP with UGH and nadroparin calcium. So the D-dimer level exceeded norm respectively by 67 % (р=0,017 and 65,9 % (р<0,05. In patients of 3 and 4 groups D-dimer level was the lowest that formed deficiency by 56 % (р<0,05 and 52,7 % (р<0,05 from the norm respectively. At the same time an analysis of

  9. Results from the CDE phase activity on neutron dosimetry for the international fusion materials irradiation facility test cell

    CERN Document Server

    Esposito, B; Maruccia, G; Petrizzi, L; Bignon, G; Blandin, C; Chauffriat, S; Lebrun, A; Recroix, H; Trapp, J P; Kaschuck, Y

    2000-01-01

    The international fusion materials irradiation facility (IFMIF) project deals with the study of an accelerator-based, deuterium-lithium source, producing high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials for fusion energy reactors. IFMIF would also provide calibration and validation of data from fission reactor and other accelerator based irradiation tests. This paper describes the activity on neutron/gamma dosimetry (necessary for the characterization of the specimens' irradiation) performed in the frame of the IFMIF conceptual design evaluation (CDE) neutronics tasks. During the previous phase (conceptual design activity (CDA)) the multifoil activation method was proposed for the measurement of the neutron fluence and spectrum and a set of suitable foils was defined. The cross section variances and covariances of this set of foils have now been used for tests on the sensitivity of the IFMIF neutron spectrum determination to cross section uncertainties...

  10. Curriculum enrichment with self-testing activities in development of fundamental movement skills of first-grade children in Greece.

    Science.gov (United States)

    Karabourniotis, Dimitrios; Evaggelinou, Christina; Tzetzis, George; Kourtessis, Thomas

    2002-06-01

    The purpose of this study was to investigate the effect of self-testing activities on the development of fundamental movement skills in first-grade children in Greece. Two groups of children were tested. The Control group (n = 23 children) received the regular 12-wk. physical education school program and the Experimental group (n = 22 children) received a 12-wk. skill-oriented program with an increasing allotment of self-testing activities. The Test of Gross Motor Development was used to assess fundamental movement skills, while the content areas of physical education courses were estimated with an assessment protocol, based on the interval recording system called the Academic Learning Time-Physical Education. A 2 x 2 repeated measures analysis of variance with group as the between factor and testing time (pretest vs posttest) as the repeated-measures factor was performed to assess differences between the two groups. A significant interaction of group with testing time was found for the Test of Gross Motor Development total score, with the Experimental group scoring higher then the Control group. A significant main effect was also found for test but not for group. This study provides evidence supporting the notion that a balanced allotment of the self-testing and game activities beyond the usual curriculum increases the fundamental motor-skill development of children. Also, it stresses the necessity for content and performance standards for the fundamental motor skills in educational programs. Finally, it seems that the Test of Gross Motor Development is a useful tool for the assessment of children's fundamental movement skills.

  11. The Electromechanical Low-Power Active Suspension: Modeling, Control, and Prototype Testing

    NARCIS (Netherlands)

    Evers, W.J.E.; Teerhuis, A.P.; Knaap, van der A.C.M.; Besselink, I.J.M.; Nijmeijer, H.

    2011-01-01

    The high energy consumption of market-ready active suspension systems is the limiting factor in the competition with semi-active devices. The variable geometry active suspension is an alternative with a significantly lower power consumption. However, previous designs suffer from packaging problems,

  12. The electromechanical low-power active suspension: modeling, control, and prototype testing

    NARCIS (Netherlands)

    Evers, W.J.; Teerhuis, A.P.; Knaap, A. van der; Besselink, I.; Nijmeijer, H.

    2011-01-01

    The high energy consumption of market-ready active suspension systems is the limiting factor in the competition with semi-active devices. The variable geometry active suspension is an alternative with a significantly lower power consumption. However, previous designs suffer from packaging problems,

  13. Evaluation of the β-CARBA™ test, a colorimetric test for the rapid detection of carbapenemase activity in Gram-negative bacilli.

    Science.gov (United States)

    Bernabeu, Sandrine; Dortet, Laurent; Naas, Thierry

    2017-06-01

    There is an urgent need for accurate and fast diagnostic tests to identify carbapenemase-producing bacteria. Here, we have evaluated a novel colorimetric test (the β-CARBA™ test; Bio-Rad) to detect carbapenemase-producing Gram-negative bacilli from cultured colonies. The performance of the β-CARBA™ test was compared with that of the Carba NP test (or the CarbAcineto NP test) and RAPIDEC ® CARBA NP (bioMérieux) using a collection of 290 isolates with characterized β-lactamase content. This collection included 199 carbapenemase producers (121 Enterobacteriaceae, 36 Pseudomonas and 42 Acinetobacter baumannii ) and 91 non-carbapenemase producers (55 Enterobacteriaceae, 20 Pseudomonas and 16 A. baumannii ). The β-CARBA™ test correctly detected 84.9% of the carbapenemase producers, including all KPC and IMP, 96.4% of VIM, 85.3% of NDM, 80.5% of OXA-48-like and 91.2% of A. baumannii -related OXA carbapenemases (OXA-23, OXA-40, OXA-58, OXA-143 and overexpressed OXA-51). All rare metallo-β-lactamases (SPM, AIM, GIM, DIM and SIM) were detected. Importantly, all non-KPC Ambler class A carbapenemases were not detected, including GES variants with carbapenemase activity ( n  = 6), IMI ( n  = 3), NMC-A ( n  = 1), SME ( n  = 2), FRI-1 ( n  = 1) and BIC-1 ( n  = 1). All non-carbapenemase producers gave a negative result except with OXA-163-, OXA-405- and one TEM-3-producing Citrobacter freundii . The overall sensitivity and specificity of the β-CARBA™ test were 84.9% and 95.6%, respectively. This test is easy to perform and to interpret by non-specialized staff members. Despite lack of specificity towards non-KPC Ambler class A and OXA-48-like carbapenemases, the β-CARBA™ test could complete the existing panel of tests available for the confirmation of carbapenemases in Gram-negatives. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For

  14. Ventral striatal activity correlates with memory confidence for old- and new-responses in a difficult recognition test.

    Directory of Open Access Journals (Sweden)

    Ulrike Schwarze

    Full Text Available Activity in the ventral striatum has frequently been associated with retrieval success, i.e., it is higher for hits than correct rejections. Based on the prominent role of the ventral striatum in the reward circuit, its activity has been interpreted to reflect the higher subjective value of hits compared to correct rejections in standard recognition tests. This hypothesis was supported by a recent study showing that ventral striatal activity is higher for correct rejections than hits when the value of rejections is increased by external incentives. These findings imply that the striatal response during recognition is context-sensitive and modulated by the adaptive significance of "oldness" or "newness" to the current goals. The present study is based on the idea that not only external incentives, but also other deviations from standard recognition tests which affect the subjective value of specific response types should modulate striatal activity. Therefore, we explored ventral striatal activity in an unusually difficult recognition test that was characterized by low levels of confidence and accuracy. Based on the human uncertainty aversion, in such a recognition context, the subjective value of all high confident decisions is expected to be higher than usual, i.e., also rejecting items with high certainty is deemed rewarding. In an accompanying behavioural experiment, participants rated the pleasantness of each recognition response. As hypothesized, ventral striatal activity correlated in the current unusually difficult recognition test not only with retrieval success, but also with confidence. Moreover, participants indicated that they were more satisfied by higher confidence in addition to perceived oldness of an item. Taken together, the results are in line with the hypothesis that ventral striatal activity during recognition codes the subjective value of different response types that is modulated by the context of the recognition test.

  15. Psychosocial correlates to high school girls' leisure-time physical activity: a test of the theory of planned behavior.

    Science.gov (United States)

    Kerner, Matthew S; Kurrant, Anthony B

    2003-12-01

    This study was designed to test the efficacy of the theory of planned behavior in predicting intention to engage in leisure-time physical activity and leisure-time physical activity behavior of high school girls. Rating scales were used for assessing attitude to leisure-time physical activity, subjective norm, perceived control, and intention to engage in leisure-time physical activity among 129 ninth through twelfth graders. Leisure-time physical activity was obtained from 3-wk. diaries. The first hierarchical multiple regression indicated that perceived control added (R2 change = .033) to the contributions of attitude to leisure-time physical activity and subjective norm in accounting for 50.7% of the total variance of intention to engage in leisure-time physical activity. The second regression analysis indicated that almost 10% of the variance of leisure-time physical activity was explicated by intention to engage in leisure-time physical activity and perceived control, with perceived control contributing 6.4%. From both academic and theoretical standpoints, our findings support the theory of planned behavior, although quantitatively the variance of leisure-time physical activity was not well-accounted for. In addition, considering the small percentage increase in variance explained by the addition of perceived control explaining variance of intention to engage in leisure-time physical activity, the pragmatism of implementing the measure of perceived control is questionable for this population.

  16. Oral-Fluid Thiol-Detection Test Identifies Underlying Active Periodontal Disease Not Detected by the Visual Awake Examination.

    Science.gov (United States)

    Queck, Katherine E; Chapman, Angela; Herzog, Leslie J; Shell-Martin, Tamara; Burgess-Cassler, Anthony; McClure, George David

    Periodontal disease in dogs is highly prevalent but can only be accurately diagnosed by performing an anesthetized oral examination with periodontal probing and dental radiography. In this study, 114 dogs had a visual awake examination of the oral cavity and were administered an oral-fluid thiol-detection test prior to undergoing a a full-mouth anesthetized oral examination and digital dental radiographs. The results show the visual awake examination underestimated the presence and severity of active periodontal disease. The thiol-detection test was superior to the visual awake examination at detecting the presence and severity of active periodontal disease and was an indicator of progression toward alveolar bone loss. The thiol-detection test detected active periodontal disease at early stages of development, before any visual cues were present, indicating the need for intervention to prevent periodontal bone loss. Early detection is important because without intervention, dogs with gingivitis (active periodontal disease) progress to irreversible periodontal bone loss (stage 2+). As suggested in the current AAHA guidelines, a thiol-detection test administered in conjunction with the visual awake examination during routine wellness examinations facilitates veterinarian-client communication and mitigates under-diagnosis of periodontal disease and underutilization of dental services. The thiol-detection test can be used to monitor the periodontal health status of the conscious patient during follow-up examinations based on disease severity.

  17. Efficiency of biological activator formulated material (BAFM) for volatile organic compounds removal--preliminary batch culture tests with activated sludge.

    Science.gov (United States)

    Corre, Charline; Couriol, Catherine; Amrane, Abdeltif; Dumont, Eric; Andrès, Yves; Le Cloirec, Pierre

    2012-01-01

    During biological degradation, such as biofiltration of air loaded with volatile organic compounds, the pollutant is passed through a bed packed with a solid medium acting as a biofilm support. To improve microorganism nutritional equilibrium and hence to enhance the purification capacities, a Biological Activator Formulated Material (BAFM) was developed, which is a mixture of solid nutrients dissolving slowly in a liquid phase. This solid was previously validated on mineral pollutants: ammonia and hydrogen sulphide. To evaluate the efficiency of such a material for biodegradation of some organic compounds, a simple experiment using an activated sludge batch reactor was carried out. The pollutants (sodium benzoate, phenol, p-nitrophenol and 2-4-dichlorophenol) were in the concentration range 100 to 1200 mg L(-1). The positive impact of the formulated material was shown. The improvement of the degradation rates was in the range 10-30%. This was the consequence of the low dissolution of the nutrients incorporated during material formulation, followed by their consumption by the biomass, as shown for urea used as a nitrogen source. Owing to its twofold interest (mechanical resistance and nutritional supplementation), the Biological Activator Formulated Material seems to be a promising material. Its addition to organic or inorganic supports should be investigated to confirm its relevance for implementation in biofilters.

  18. R and D of low activated Fe-Mn-Cr high strength non-magnetic steel, (I). Screening test for constituent optimization and fundamental characterization test

    Energy Technology Data Exchange (ETDEWEB)

    Ishiyama, Shintaro; Fukaya, Kiyoshi; Eto, Motokuni; Kikuchi, Mituru [Japan Atomic Energy Research Inst., Tokyo (Japan); Sato, Ikuo; Kusuhashi, Mikio; Hatakeyama, Tuyoshi [Japan Steel Works Ltd., Tokyo (Japan); Takahashi, Heishitiro [Center for Advanced Research of Energy Technology, Hokkaido Univ., Sapporo (Japan)

    2000-02-01

    It is very important to develop low activated/non-magnetic materials as large scale structural materials for fusion reactors. In the structural design of JT-60SU, low activated/non-magnetic materials with high specific strength and low decay heat characterizations are required. In the present paper, a new low activated/non-magnetic material (15.5 Mn-16Cr-0.2N-0.3Si-0.2C (wt%)) based on the conventional high manganese steel with lower Ni, CO, C, N and Mn contents for the purpose of lower activation and decay heat was developed and the mass production conditions of the material were optimized. Fundamental material characterization tests of the new material developed in present study were carried out, and the following conclusions are derived ; (1) Lower activation characterizations with the new materials in the order of 1/10 of that of SUS316L steel, (2) Higher strength of the material in the order of 2{approx}3 of SUS316L steel and (3) Lower decay heat with higher thermal conductivity with comparison of SUS316L steel. (author)

  19. Seismic functional qualification of active mechanical and electrical component based on shaking table testing

    International Nuclear Information System (INIS)

    Jurukovski, D.; Mamucevski, D.

    1996-01-01

    This report involves the description of the experimental seismic and vibration tests of electrical, mechanical and processing equipment that were carried out by using laboratory equipment with high performances. This equipment should generate programmable dynamic excitations, measure and analyze parameters defining dynamic behaviour of the structural and functional capabilities of the tested specimen. Development of testing methodology and criteria is described together with the method for processing the results. Application of the methodology and criteria to selected specimen is included

  20. Antidepressant-like activity of resveratrol treatment in the forced swim test and tail suspension test in mice: the HPA axis, BDNF expression and phosphorylation of ERK.

    Science.gov (United States)

    Wang, Zhen; Gu, Jianhua; Wang, Xueer; Xie, Kai; Luan, Qinsong; Wan, Nianqing; Zhang, Qun; Jiang, Hong; Liu, Dexiang

    2013-11-01

    Resveratrol is a natural polyphenol enriched in Polygonum cuspidatum and has diverse biological activities. There is only limited information about the antidepressant-like effect of resveratrol. The present study assessed whether resveratrol treatment (20, 40 and 80mg/kg, i.p., 21days) has an antidepressant-like effect on the forced swim test (FST) and tail suspension test (TST) in mice and examined what its molecular targets might be. The results showed that resveratrol administration produced antidepressant-like effects in mice, evidenced by the reduced immobility time in the FST and TST, while it had no effect on the locomotor activity in the open field test. Resveratrol treatment significantly reduced serum corticosterone levels, which had been elevated by the FST and TST. Moreover, resveratrol increased brain-derived neurotrophic factor (BDNF) protein and extracellular signal-regulated kinase (ERK) phosphorylation levels in the prefrontal cortex and hippocampus. All of these antidepressant-like effects of resveratrol were essentially similar to those observed with the clinical antidepressant, fluoxetine. These results suggest that the antidepressant-like effects of resveratrol in the FST and TST are mediated, at least in part, by modulating hypothalamic-pituitary-adrenal axis, BDNF and ERK phosphorylation expression in the brain region of mice. © 2013.

  1. Test-retest paradigm of the forced swimming test in female mice is not valid for predicting antidepressant-like activity: participation of acetylcholine and sigma-1 receptors.

    Science.gov (United States)

    Su, Jing; Hato-Yamada, Noriko; Araki, Hiroaki; Yoshimura, Hiroyuki

    2013-01-01

    The forced swimming test (FST) in mice is widely used to predict the antidepressant activity of a drug, but information describing the immobility of female mice is limited. We investigated whether a prior swimming experience affects the immobility duration in a second FST in female mice and whether the test-retest paradigm is a valid screening tool for antidepressants. Female ICR mice were exposed to the FST using two experimental paradigms: a single FST and a double FST in which mice had experienced FST once 24 h prior to the second trail. The initial FST experience reliably prolonged immobility duration in the second FST. The antidepressants imipramine and paroxetine significantly reduced immobility duration in the single FST, but not in the double FST. Scopolamine and the sigma-1 (σ1) antagonist NE-100 administered before the second trial significantly prevented the prolongation of immobility. Neither a 5-HT1A nor a 5-HT2A receptor agonist affected immobility duration. We suggest that the test-retest paradigm in female mice is not adequate for predicting antidepressant-like activity of a drug; the prolongation of immobility in the double FST is modulated through acetylcholine and σ1 receptors.

  2. Test to Extract Soil Properties Using the Seismic HammerTM Active Seismic Source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Rebekah F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Abbott, Robert E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    Geologic material properties are necessary parameters for ground motion modeling and are difficult and expensive to obtain via traditional methods. Alternative methods to estimate soil properties require a measurement of the ground's response to a force. A possible method of obtaining these measurements is active-source seismic surveys, but measurements of the ground response at the source must also be available. The potential of seismic sources to obtain soil properties is limited, however, by the repeatability of the source. Explosives, and hammer surveys are not repeatable because of variable ground coupling or swing strength. On the other hand, the Seismic Hammer TM (SH) is consistent in the amount of energy it inputs into the ground. In addition, it leaves large physical depressions as a result of ground compaction. The volume of ground compaction varies by location. Here, we hypothesize that physical depressions left in the earth by the SH correlate to energy recorded by nearby geophones, and therefore are a measurement of soil physical properties. Using measurements of the volume of shot holes, we compare the spatial distribution of the volume of ground compacted between the different shot locations. We then examine energy recorded by the nearest 50 geophones and compare the change in amplitude across hits at the same location. Finally, we use the percent difference between the energy recorded by the first and later hits at a location to test for a correlation to the volume of the shot depressions. We find that: * Ground compaction at the shot-depression does cluster geographically, but does not correlate to known surface features. * Energy recorded by nearby geophones reflects ground refusal after several hits. * There is no correlation to shot volume and changes in energy at particular shot locations. Deeper material properties (i.e. below the depth of surface compaction) may be contributing to the changes in energy propagation. * Without further

  3. Summary of the last step of active test at separation facility and purification facility in Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Kuroishi, Yuuki; Iseki, Tadahiro; Mitani, Akira; Takahashi, Naoki; Tsujimura, Akino; Sato, Nobuharu; Inaba, Makoto; Itagaki, Takashi

    2008-01-01

    During the last step of Active Test (AT) at Rokkasho Reprocessing Plant (RRP), the performance of the Separation Facility, mainly for pulsed columns and mixer-settlers were tested; Diluent washing efficiency, Plutonium extraction and stripping efficiency, Decontamination factors of fission products and Uranium and plutonium losses into wastes. Also, those of the Plutonium purification unit in the Purification Facility have been checked; Diluent washing efficiency, Plutonium extraction and stripping efficiency and Plutonium losses into wastes. Test results were equivalent to or better than expected values. (author)

  4. Antibacterial Activity of Different Plant Extracts and Phenolic Phytochemicals Tested on Paenibacillus Larvae Bacteria

    Directory of Open Access Journals (Sweden)

    Liviu Mărghitaş

    2011-10-01

    Full Text Available Paenibacillus larvae, a Gram-positive and spore-forming bacterium is responsible for American foulbrood disease inbees. The antimicrobial activity of different plant extracts and phenolic phytochemical was evaluated onPaenibacillus larvae bacteria. In addition possible correlation with antioxidant activity of the same plant extracts wasstudied. Extracts of the following plants were utilized: Achillea millefolium (yarrow, Ocimum basilicum (basil,Thymus vulgaris (thyme and Urtica dioica (nettle. The extracts that showed antimicrobial activity were later testedto determine the Minimal Inhibitory Concentration (MIC. Although nettle present the lowest polyphenolic contentcompared with the other plant extracts, exhibit the highest antimicrobial activity, measured as the inhibition zoneusing Mueller-Hinton agar plates. Basil presented both polyphenolic content and antimicrobial activity at higherlevels, while thyme had the lowest antimicrobial activity, even it present high amount of polyphenols.

  5. Female PFP patients present alterations in eccentric muscle activity but not the temporal order of activation of the vastus lateralis muscle during the single leg triple hop test.

    Science.gov (United States)

    Kalytczak, Marcelo Martins; Lucareli, Paulo Roberto Garcia; Dos Reis, Amir Curcio; Bley, André Serra; Biasotto-Gonzalez, Daniela Aparecida; Correa, João Carlos Ferrari; Politti, Fabiano

    2018-04-07

    This study aimed to compare the concentric and eccentric activity and the temporal order of peak activity of the hip and knee muscles between women with patellofemoral pain (PFP) and healthy women during the single leg triple hop test (SLTHT). Electromyographic (EMG) and Kinematic data were collected from 14 healthy women (CG) and 14 women diagnosed with PFP (PFG) during a single session of the single leg triple hop test. Integral surface electromyography (iEMG) data of the hip and knee muscles in eccentric and concentric phases and the length of time that each muscle needed to reach the maximal peak of muscle activity were calculated. The iEMG in the eccentric phase was significantly higher (p < 0.05) than the concentric phase, for the gluteus maximus and gluteus medius muscles (CG and PFG) and for the vastus lateralis muscle (PFG). The vastus lateralis muscle was the first muscle to reach the highest peak of activity in the PFG, and the third to reach this peak in the CG. In the present study, the activity of the vastus lateralis muscle during the eccentric phase of the jump was greater than concentric phase, as a temporal anticipation of its peak in activity among women with PFP. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Construct validity of a revised Physical Activity Scale and testing by cognitive interviewing

    DEFF Research Database (Denmark)

    Andersen, Lise G; Groenvold, Mogens; Jørgensen, Torben

    2010-01-01

    ), previously found to overestimate physical activity. RESULTS: Cognitive interviewing revealed few problems in the questions on physical activity in different domains. No problems regarding the structure of the questionnaire were identified. The agreement between PAS 1 and PAS 2 MET-scores was high among...... was evaluated by cognitive interviewing in 16 Danish men and women aged 21-70 years. Construct validity was validated in 342 men and women aged 35-66 years by assessing agreement between 24-h MET-scores obtained from average weekly physical activity measured by PAS 2 and a 24-h Physical Activity Scale (PAS 1...

  7. The sensitivity of tests to detect in vivo platelet activation induced by ...

    African Journals Online (AJOL)

    No influence on the results of the platelet function tests was found. Tile only test capable of detecting limited injury to the endothelium was the measurement of plasma PF4: The mean platelet life-span (MPLS) shortened, mean platelet density decreased, the circulating platelet aggregate ratio decreased, and plasma levels ...

  8. Performance testing of high specific activity waste forms per 10 CFR Part 61

    International Nuclear Information System (INIS)

    Neilson, R.M. Jr.; McConnell, J.W. Jr.; Rogers, R.D.

    1987-03-01

    The Low-Level Waste Data Base Development - EPICOR-II Resin/Liner Investigation Program of the US Nuclear Regulatory Commission (NRC) is obtaining information on radioactive waste by means of NRC-prescribed tests in a disposal environment. This paper describes the resin solidification task of that program and includes the current test status and results. 28 refs., 5 figs., 6 tabs

  9. Critical Evaluation of Animal Alternative Tests for the Identification of Endocrine Active Substances

    Science.gov (United States)

    A significant amount of research is currently targeted to evaluate alternative test methods that may reduce, refine, or replace the use of animals, while ensuring human and environmental health and safety. It is important that the information gained from the alternative tests pr...

  10. Small-scale and large-scale testing of photo-electrochemically activated leaching technology in Aprelkovo and Delmachik Mines

    Science.gov (United States)

    Sekisov, AG; Lavrov, AYu; Rubtsov, YuI

    2017-02-01

    The paper gives a description of tests and trials of the technology of heap gold leaching from rebellious ore in Aprelkovo and Delmachik Mines. Efficiency of leaching flowsheets with the stage-wise use of activated solutions of different reagents, including active forms of oxygen, is evaluated. Carbonate-peroxide solutions are used at the first stage of leaching to oxidize sulfide and sulfide-arsenide ore minerals to recover iron and copper from them. The second stage leaching uses active cyanide solutions to leach encapsulated and disperse gold and silver.

  11. Overview of results of the first phase of validation activities for the IFMIF High Flux Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Arbeiter, Frederik, E-mail: frederik.arbeiter@kit.edu [Karlsruhe Institute of Technology, Karlsruhe (Germany); Chen Yuming; Dolensky, Bernhard; Freund, Jana; Heupel, Tobias; Klein, Christine; Scheel, Nicola; Schlindwein, Georg [Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Validation of computational fluid dynamics (CFD) modeling approach for application in the IFMIF High Flux Test Module. Black-Right-Pointing-Pointer Fabrication of prototypes of the irradiation capsules of the IFMIF High Flux Test Module. - Abstract: The international fusion materials irradiation facility (IFMIF) is projected to create an experimentally validated database of material properties relevant for fusion reactor designs. The IFMIF High Flux Test Module is the dedicated experiment to irradiate alloys in the temperature range 250-550 Degree-Sign C and up to 50 displacements per atom per irradiation cycle. The High Flux Test Module is developed to maximize the specimen payload in the restricted irradiation volume, and to minimize the temperature spread within each specimen bundle. Low pressure helium mini-channel cooling is used to offer a high integration density. Due to the demanding thermo-hydraulic and mechanical conditions, the engineering design process (involving numerical neutronic, thermo-hydraulic and mechanical analyses) is supported by extensive experimental validation activities. This paper reports on the prototype manufacturing, thermo-hydraulic modeling experiments and component tests, as well as on mechanical testing. For the testing of the 1:1 prototype of the High Flux Test Module, a dedicated test facility, the Helium Loop Karlsruhe-Low Pressure (HELOKA-LP) has been taken into service.

  12. Overview of results of the first phase of validation activities for the IFMIF High Flux Test Module

    International Nuclear Information System (INIS)

    Arbeiter, Frederik; Chen Yuming; Dolensky, Bernhard; Freund, Jana; Heupel, Tobias; Klein, Christine; Scheel, Nicola; Schlindwein, Georg

    2012-01-01

    Highlights: ► Validation of computational fluid dynamics (CFD) modeling approach for application in the IFMIF High Flux Test Module. ► Fabrication of prototypes of the irradiation capsules of the IFMIF High Flux Test Module. - Abstract: The international fusion materials irradiation facility (IFMIF) is projected to create an experimentally validated database of material properties relevant for fusion reactor designs. The IFMIF High Flux Test Module is the dedicated experiment to irradiate alloys in the temperature range 250–550 °C and up to 50 displacements per atom per irradiation cycle. The High Flux Test Module is developed to maximize the specimen payload in the restricted irradiation volume, and to minimize the temperature spread within each specimen bundle. Low pressure helium mini-channel cooling is used to offer a high integration density. Due to the demanding thermo-hydraulic and mechanical conditions, the engineering design process (involving numerical neutronic, thermo-hydraulic and mechanical analyses) is supported by extensive experimental validation activities. This paper reports on the prototype manufacturing, thermo-hydraulic modeling experiments and component tests, as well as on mechanical testing. For the testing of the 1:1 prototype of the High Flux Test Module, a dedicated test facility, the Helium Loop Karlsruhe-Low Pressure (HELOKA-LP) has been taken into service.

  13. Clinimetric properties of the Tinetti Mobility Test, Four Square Step Test, Activities-specific Balance Confidence Scale, and spatiotemporal gait measures in individuals with Huntington's disease.

    Science.gov (United States)

    Kloos, Anne D; Fritz, Nora E; Kostyk, Sandra K; Young, Gregory S; Kegelmeyer, Deb A

    2014-09-01

    Individuals with Huntington's disease (HD) experience balance and gait problems that lead to falls. Clinicians currently have very little information about the reliability and validity of outcome measures to determine the efficacy of interventions that aim to reduce balance and gait impairments in HD. This study examined the reliability and concurrent validity of spatiotemporal gait measures, the Tinetti Mobility Test (TMT), Four Square Step Test (FSST), and Activities-specific Balance Confidence (ABC) Scale in individuals with HD. Participants with HD [n = 20; mean age ± SD=50.9 ± 13.7; 7 male] were tested on spatiotemporal gait measures and the TMT, FSST, and ABC Scale before and after a six week period to determine test-retest reliability and minimal detectable change (MDC) values. Linear relationships between gait and clinical measures were estimated using Pearson's correlation coefficients. Spatiotemporal gait measures, the TMT total and the FSST showed good to excellent test-retest reliability (ICC > 0.75). MDC values were 0.30 m/s and 0.17 m/s for velocity in forward and backward walking respectively, four points for the TMT, and 3s for the FSST. The TMT and FSST were highly correlated with most spatiotemporal measures. The ABC Scale demonstrated lower reliability and less concurrent validity than other measures. The high test-retest reliability over a six week period and concurrent validity between the TMT, FSST, and spatiotemporal gait measures suggest that the TMT and FSST may be useful outcome measures for future intervention studies in ambulatory individuals with HD. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Design and test of a novel magnetic lead screw for active suspension system in a vehicle

    DEFF Research Database (Denmark)

    Berg, Nick Ilsø; Holm, Rasmus Koldborg; Rasmussen, Peter Omand

    2014-01-01

    . Furthermore the Magnetic Lead Screw is introduced and its benefits when used with an active suspension system are discussed. Based on a model of a quarter car, the design specifications for the MLS active suspension system are found, which leads to a design study. The design study investigates the relation...

  15. Solar Energy Education. Humanities: activities and teacher's guide. Field test edition

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    Activities are outlined to introduce students to information on solar energy while performing ordinary classroom work. In this teaching manual solar energy is integrated with the humanities. The activities include such things as stories, newspapers, writing assignments, and art and musical presentations all filled with energy related terms. An energy glossary is provided. (BCS)

  16. Factors Predicting the Physical Activity Behavior of Female Adolescents: A Test of the Health Promotion Model

    Directory of Open Access Journals (Sweden)

    Hashem Mohamadian

    2014-01-01

    Full Text Available ObjectivesPhysical activity behavior begins to decline during adolescence and continues to decrease throughout young adulthood. This study aims to explain factors that influence physical activity behavior in a sample of female adolescents using a health promotion model framework.MethodsThis cross-sectional survey was used to explore physical activity behavior among a sample of female adolescents. Participants completed measures of physical activity, perceived self-efficacy, self-esteem, social support, perceived barriers, and perceived affect. Interactions among the variables were examined using path analysis within a covariance modeling framework.ResultsThe final model accounted for an R2 value of 0.52 for physical activity and offered a good model-data fit. The results indicated that physical activity was predicted by self-esteem (β=0.46, p<0.001, perceived self-efficacy (β=0.40, p<0.001, social support (β=0.24, p<0.001, perceived barriers (β=-0.19, p<0.001, and perceived affect (β=0.17, p<0.001.ConclusionsThe findings of this study showed that the health promotion model was useful to predict physical activity behavior among the Iranian female adolescents. Information related to the predictors of physical activity behavior will help researchers plan more tailored culturally relevant health promotion interventions for this population.

  17. TCR-Vß8 as alternative to animal testing for quantifying active SEE

    Science.gov (United States)

    Staphylococcal food poisoning is a result of ingestion of Staphylococcal enterotoxins (SEs) produced by the bacterium Staphylococcus aureus. SEs cause gastroenteritis and also cause activation of T cells and massive cytokine release. A current method for the detection of active SEs relies on its eme...

  18. A comparative evaluation of in vitro skin sensitisation tests: the human cell-line activation test (h-CLAT) versus the local lymph node assay (LLNA).

    Science.gov (United States)

    Ashikaga, Takao; Sakaguchi, Hitoshi; Sono, Sakiko; Kosaka, Nanae; Ishikawa, Makie; Nukada, Yuko; Miyazawa, Masaaki; Ito, Yuichi; Nishiyama, Naohiro; Itagaki, Hiroshi

    2010-08-01

    We previously developed the human cell-line activation test (h-CLAT) in vitro skin sensitisation test, based on our reported finding that a 24-hour exposure of THP-1 cells (a human monocytic leukaemia cell line) to sensitisers is sufficient to induce the augmented expression of CD86 and CD54. The aim of this study is to confirm the predictive value of h-CLAT for skin sensitisation activity by employing a larger number of test chemicals. One hundred chemicals were selected, according to their categorisation in the local lymph node assay (LLNA), as being: extreme, strong, moderate and weak sensitisers, and non-sensitisers. The correlation of the h-CLAT results with the LLNA results was 84%. There were some false negatives (e.g. benzoyl peroxide, hexyl cinnamic aldehyde) and some false positives (e.g. 1-bromobutane, diethylphthalate). Eight out of the 9 false negatives (89%) were water-insoluble chemicals. The h-CLAT could positively predict not only extreme and strong sensitisers, but also moderate and weak sensitisers, though the detection rates of weak sensitisers and non-sensitisers were comparatively low. Some sensitisers enhanced both CD86 and CD54 levels, and some enhanced the level of only one of them. The use of the combination of CD86 and CD54 induction as a positive indicator, improved the accuracy of the test. In conclusion, the h-CLAT is expected to be a useful cell-based in vitro method for predicting skin sensitisation potential. 2010 FRAME.

  19. The Physical Activity Scale for Individuals with Physical Disabilities : test-retest reliability and comparison with an accelerometer

    NARCIS (Netherlands)

    van der Ploeg, Hidde P; Streppel, Kitty R M; van der Beek, Allard J; van der Woude, Luc H V; Vollenbroek-Hutten, Miriam; van Mechelen, Willem; van der Woude, Lucas

    BACKGROUND: The objective was to determine the test-retest reliability and criterion validity of the Physical Activity Scale for Individuals with Physical Disabilities (PASIPD). METHODS: Forty-five non-wheelchair dependent subjects were recruited from three Dutch rehabilitation centers. Subjects'

  20. Differences in physical-fitness test scores between actively and passively recruited older adults : Consequences for norm-based classification

    NARCIS (Netherlands)

    van Heuvelen, M.J.G.; Stevens, M.; Kempen, G.I.J.M.

    This study investigated differences in physical-fitness test scores between actively and passively recruited older adults and the consequences thereof for norm-based classification of individuals. Walking endurance, grip strength, hip flexibility, balance, manual dexterity, and reaction time were

  1. Study-Test Congruency Affects Encoding-Related Brain Activity for Some but Not All Stimulus Materials

    Science.gov (United States)

    Bauch, Eva M.; Otten, Leun J.

    2012-01-01

    Memory improves when encoding and retrieval processes overlap. Here, we investigated how the neural bases of long-term memory encoding vary as a function of the degree to which functional processes engaged at study are engaged again at test. In an incidental learning paradigm, electrical brain activity was recorded from the scalps of healthy…

  2. Correlation of secretory phospholipase-A2 activity and fatty acids in cerebrospinal fluid with liver enzymes tests

    Directory of Open Access Journals (Sweden)

    Sepideh Ghodoosifar

    2016-02-01

    Full Text Available Introduction: The aim was to determine whether secretory phospholipase-A2 (sPLA2 activity and fatty acids in cerebrospinal fluid (CSF are correlated with liver enzymes tests. Methods: CSF and serum samples were collected from 49 patients (age 18-65 as part of routine diagnostic testing. Along with serum liver enzymes aspartate aminotransferase (AST, alanine aminotransferase (ALT and alkaline phosphatase (ALP, the fatty acid composition of CSF was measured by gas liquid chromatography. CSF enzyme activities of sPLA2 were measured using the standard assay with diheptanoyl thio-phosphatidylcholin as substrate. Results: The saturated fatty acids (SFAs including palmitic acid and stearic acid were positively, and the unsaturated fatty acids including oleic acid and linoleic acid were negatively correlated with liver enzymes tests. In regression analysis with adjustment for body mass index (BMI, the elevated liver enzymes tests were positively associated with activity of sPLA2 (β > 0.31, P 0.38, P < 0.010 and negatively with total monounsaturated fatty acids (MUFAs (β < -0.40, P < 0.001 contents of CSF. Conclusion: CSF activity of sPLA2 and fatty acids may be linked to peripheral markers of liver function, suggesting an indirect impact of central fatty acids on hepatocytes function and metabolism.

  3. Model tests for the efficacy of disinfectants on surfaces. IV. Communication: dependence of test results on the amount of contamination and the kind of active substance.

    Science.gov (United States)

    Peters, J; Spicher, G

    1998-12-01

    In the assessment of efficacy of surface disinfectants, many influencing factors have to be taken into account. One essential item is whether the surface to be disinfected is clean or soiled. Among the feasible soilings, the blood is of particular consequences because it ads impediments to many disinfecting agents. This paper shows to what extent the impairment of the efficacy of typical active agents depends on the blood burden of the surfaces. Therefore, test surfaces (varnished plywood) were contaminated with 0.01 to 0.08 ml of coagulating blood per test area (3 cm2). The blood contained cells of Staphylococcus aureus as test germs. The disinfection was effected by immersing the test objects in the disinfecting solution for 5 seconds and mingling the adhering disinfecting solution (about 0.02 ml) with the coagulated blood on the test surface with a glass spatula for about 20 seconds. Subsequently, the test objects remained in a horizontal position at room conditions for 4 hours and then the numbers of surviving test germs were determined. The graphical representation of the results shows that the efficacy curves of formaldehyde and phenol lie very closely together, i.e. their effect is hardly impaired by the different blood burdens of the test areas. The efficacy curves of glutaraldehyde, peracetic acid, chloramine T, and quaternary ammonium compounds lie very far apart from each other. To achieve the same microbicidal effect (log N/N0 = -5) when the contaminating amount is raised from 10 microliters/3 cm2 to 80 microliters/3 cm2, the concentration of chloramine T has to be raised by a factor of 5.4, peracetic acid by a factor of 9, glutaraldehyde by a factor of 24, quaternary ammonium compound even by a factor of 67. Ethanol and sodium hypochlorite showed a divergent behaviour. For ethanol, the efficacy diminution produced by increasing the contamination amount by a factor of 4 can be compensated by raising the concentration from 50% to about 70%. But again and

  4. Initial land reclamation procedures related to possible Pu-cleanup activities at the Tonopah Test Range

    International Nuclear Information System (INIS)

    Wallace, A.; Romney, E.M.

    1976-02-01

    If areas of the Tonopah Test Range (TTR) are to be used for experimental tests of procedures for clean-up of 239 Pu contamination, there are experiences in the Great Basin Desert portions of the Nevada Test Site (NTS) which can serve as guides to reclamation and revegetation of such arid lands. Procedures which will encourage development of the grasses Hilaria jamesii and Oryzopsis hymenoides, as well as the perennial shrubs Eurotia lanata and Atriplex canescens would greatly improve the area as range land

  5. Testing the hierarchy of effects model: ParticipACTION's serial mass communication campaigns on physical activity in Canada.

    Science.gov (United States)

    Craig, C L; Bauman, A; Reger-Nash, B

    2010-03-01

    The hierarchy of effects (HOE) model is often used in planning mass-reach communication campaigns to promote health, but has rarely been empirically tested. This paper examines Canada's 30 year ParticipACTION campaign to promote physical activity (PA). A cohort from the nationally representative 1981 Canada Fitness Survey was followed up in 1988 and 2002-2004. Modelling of these data tested whether the mechanisms of campaign effects followed the theoretical framework proposed in the HOE. Campaign awareness was measured in 1981. Outcome expectancy, attitudes, decision balance and future intention were asked in 1988. PA was assessed at all time points. Logistic regression was used to sequentially test mediating and moderating variables adjusting for age, sex and education. No selection bias was observed; however, relatively fewer respondents than non-respondents smoked or were underweight at baseline. Among those inactive at baseline, campaign awareness predicted outcome expectancy which in turn predicted positive attitude to PA. Positive attitudes predicted high decision balance, which predicted future intention. Future intention mediated the relationship between decision balance and sufficient activity. Among those sufficiently active at baseline, awareness was unrelated to outcome expectancy and inversely related to positive attitude. These results lend support to the HOE model, in that the effects of ParticipACTION's serial mass media campaigns were consistent with the sequential rollout of its messages, which in turn was associated with achieving an active lifestyle among those initially insufficiently active. This provides support to an often-used theoretical framework for designing health promotion media campaigns.

  6. Development and preliminary testing of a computerized Animated Activity Questionnaire (AAQ) in patients with hip and knee osteoarthritis

    DEFF Research Database (Denmark)

    Peter, Wf; Loos, M; de Vet, Hcw

    2015-01-01

    , and to preliminary assess its reliability and validity. We hypothesize that the AAQ correlates highly with performance-based tests, and moderately with self-reports. Methods Item selection was based on 1) the pilot AAQ; 2) pre-specified conditions; 3) the International Classification of Functioning core set for OA......Objective To develop an Animated Activity Questionnaire (AAQ), based on video animations, for assessing activity limitations in patients with hip/knee osteoarthritis (OA), which combines the advantages of self-reported questionnaires and performance-based tests, without many of their limitations......, 4) existing measurement instruments, and 5) focus groups of patients. Test-retest reliability was assessed in 30/110 patients. In 110 patients correlations were calculated between AAQ and self-reported Hip disability and Knee injury Osteoarthritis Outcome ADL subscale (H/KOOS). In 45/110 patients...

  7. Testing a workplace physical activity intervention: a cluster randomized controlled trial.

    Science.gov (United States)

    McEachan, Rosemary R C; Lawton, Rebecca J; Jackson, Cath; Conner, Mark; Meads, David M; West, Robert M

    2011-04-11

    Increased physical activity levels benefit both an individuals' health and productivity at work. The purpose of the current study was to explore the impact and cost-effectiveness of a workplace physical activity intervention designed to increase physical activity levels. A total of 1260 participants from 44 UK worksites (based within 5 organizations) were recruited to a cluster randomized controlled trial with worksites randomly allocated to an intervention or control condition. Measurement of physical activity and other variables occurred at baseline, and at 0 months, 3 months and 9 months post-intervention. Health outcomes were measured during a 30 minute health check conducted in worksites at baseline and 9 months post intervention. The intervention consisted of a 3 month tool-kit of activities targeting components of the Theory of Planned Behavior, delivered in-house by nominated facilitators. Self-reported physical activity (measured using the IPAQ short-form) and health outcomes were assessed. Multilevel modelling found no significant effect of the intervention on MET minutes of activity (from the IPAQ) at any of the follow-up time points controlling for baseline activity. However, the intervention did significantly reduce systolic blood pressure (B=-1.79 mm/Hg) and resting heart rate (B=-2.08 beats) and significantly increased body mass index (B=.18 units) compared to control. The intervention was found not to be cost-effective, however the substantial variability round this estimate suggested that further research is warranted. The current study found mixed support for this worksite physical activity intervention. The paper discusses some of the tensions involved in conducting rigorous evaluations of large-scale randomized controlled trials in real-world settings. © 2011 McEachan et al; licensee BioMed Central Ltd.

  8. Results from the CDE phase activity on neutron dosimetry for the international fusion materials irradiation facility test cell

    Energy Technology Data Exchange (ETDEWEB)

    Esposito, B. E-mail: esposito@frascati.enea.it; Bertalot, L.; Maruccia, G.; Petrizzi, L.; Bignan, G.; Blandin, C.; Chauffriat, S.; Lebrun, A.; Recroix, H.; Trapp, J.P.; Kaschuck, Y

    2000-11-01

    The international fusion materials irradiation facility (IFMIF) project deals with the study of an accelerator-based, deuterium-lithium source, producing high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials for fusion energy reactors. IFMIF would also provide calibration and validation of data from fission reactor and other accelerator based irradiation tests. This paper describes the activity on neutron/gamma dosimetry (necessary for the characterization of the specimens' irradiation) performed in the frame of the IFMIF conceptual design evaluation (CDE) neutronics tasks. During the previous phase (conceptual design activity (CDA)) the multifoil activation method was proposed for the measurement of the neutron fluence and spectrum and a set of suitable foils was defined. The cross section variances and covariances of this set of foils have now been used for tests on the sensitivity of the IFMIF neutron spectrum determination to cross section uncertainties. The analysis has been carried out using the LSL-M2 code, which optimizes the neutron spectrum by means of a least-squares technique taking into account the variance and covariance files. In the second part of the activity, the possibility of extending to IFMIF the use of existing on-line in-core neutron/gamma monitors (to be located at several positions inside the IFMIF test cell for beam control, safety and diagnostic purposes) has been studied. A feasibility analysis of the modifications required to adapt sub-miniature fission chambers (recently developed by CEA-Cadarache) to the high flux test module of the test cell has been carried out. The verification of this application pertinence and a gross definition of the in-core detector characteristics are described. The option of using self-powered neutron detectors (SPNDs) is also discussed.

  9. Adaptation, test-retest reliability, and construct validity of the Physical Activity Neighborhood Environment Scale in Nigeria (PANES-N).

    Science.gov (United States)

    Oyeyemi, Adewale L; Sallis, James F; Oyeyemi, Adetoyeje Y; Amin, Mariam M; De Bourdeaudhuij, Ilse; Deforche, Benedicte

    2013-11-01

    This study adapted the Physical Activity Neighborhood Environment Scale (PANES) to the Nigerian context and assessed the test-retest reliability and construct validity of the Nigerian version (PANESN). A multidisciplinary panel of experts adapted the original PANES to reflect the built and social environment of Nigeria. The adapted PANES was subjected to cognitive testing and test retest reliability in a diverse sample of Nigerian adults (N = 132) from different neighborhood types. Intraclass Correlation Coefficients (ICC) was used to assess test-retest reliability, and construct validity was investigated with Analysis of Covariance for differences in environmental attributes between neighborhoods. Four of the 17 items on the original PANES were significantly modified, 3 were removed and 2 new items were incorporated into the final version of adapted PANES-N. Test-retest reliability was substantial to almost perfect (ICC = 0.62-1.00) for all items on the PANES-N, and residents of neighborhoods in the inner city reported higher residential density, land use mix and safety, but lower pedestrian facilities and aesthetics than did residents of government reserved area/new layout neighborhoods. The PANES-N appears promising for assessing environmental perceptions related to physical activity in Nigeria, but further testing is required to assess its applicability across Africa.

  10. Testing Testing Testing.

    Science.gov (United States)

    Deville, Craig; O'Neill, Thomas; Wright, Benjamin D.; Woodcock, Richard W.; Munoz-Sandoval, Ana; Gershon, Richard C.; Bergstrom, Betty

    1998-01-01

    Articles in this special section consider (1) flow in test taking (Craig Deville); (2) testwiseness (Thomas O'Neill); (3) test length (Benjamin Wright); (4) cross-language test equating (Richard W. Woodcock and Ana Munoz-Sandoval); (5) computer-assisted testing and testwiseness (Richard Gershon and Betty Bergstrom); and (6) Web-enhanced testing…

  11. Outcomes and costs of incorporating a multibiomarker disease activity test in the management of patients with rheumatoid arthritis.

    Science.gov (United States)

    Michaud, Kaleb; Strand, Vibeke; Shadick, Nancy A; Degtiar, Irina; Ford, Kerri; Michalopoulos, Steven N; Hornberger, John

    2015-09-01

    The multibiomarker disease activity (MBDA) blood test has been clinically validated as a measure of disease activity in patients with RA. We aimed to estimate the effect of the MBDA test on physical function for patients with RA (based on HAQ), quality-adjusted life years and costs over 10 years. A decision analysis was conducted to quantify the effect of using the MBDA test on RA-related outcomes and costs to private payers and employers. Results of a clinical management study reporting changes to anti-rheumatic drug recommendations after use of the MBDA test informed clinical utility. The effect of treatment changes on HAQ was derived from 5 tight-control and 13 treatment-switch trials. Baseline HAQ scores and the HAQ score relationship with medical costs and quality of life were derived from published National Data Bank for Rheumatic Diseases data. Use of the MBDA test is projected to improve HAQ scores by 0.09 units in year 1, declining to 0.02 units after 10 years. Over the 10 year time horizon, quality-adjusted life years increased by 0.08 years and costs decreased by US$457 (cost savings in disability-related medical costs, US$659; in productivity costs, US$2137). The most influential variable in the analysis was the effect of the MBDA test on clinician treatment recommendations and subsequent HAQ changes. The MBDA test aids in the assessment of disease activity in patients with RA by changing treatment decisions, improving the functional status of patients and cost savings. Further validation is ongoing and future longitudinal studies are warranted. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology.

  12. Learning and memory in the forced swimming test: effects of antidepressants having varying degrees of anticholinergic activity.

    Science.gov (United States)

    Enginar, Nurhan; Yamantürk-Çelik, Pınar; Nurten, Asiye; Güney, Dilvin Berrak

    2016-07-01

    The antidepressant-induced reduction in immobility time in the forced swimming test may depend on memory impairment due to the drug's anticholinergic efficacy. Therefore, the present study evaluated learning and memory of the immobility response in rats after the pretest and test administrations of antidepressants having potent, comparatively lower, and no anticholinergic activities. Immobility was measured in the test session performed 24 h after the pretest session. Scopolamine and MK-801, which are agents that have memory impairing effects, were used as reference drugs for a better evaluation of the memory processes in the test. The pretest administrations of imipramine (15 and 30 mg/kg), amitriptyline (7.5 and 15 mg/kg), trazodone (10 mg/kg), fluoxetine (10 and 20 mg/kg), and moclobemide (10 and 20 mg/kg) were ineffective, whereas the pretest administrations of scopolamine (0.5 mg/kg) and MK-801 (0.1 mg/kg) decreased immobility time suggesting impaired "learning to be immobile" in the animals. The test administrations of imipramine (30 mg/kg), amitriptyline (15 mg/kg), moclobemide (10 mg/kg), scopolamine (0.5 and 1 mg/kg), and MK-801 (0.1 mg/kg) decreased immobility time, which suggested that the drugs exerted antidepressant activity or the animals did not recall that attempting to escape was futile. The test administrations of trazodone (10 mg/kg) and fluoxetine (10 and 20 mg/kg) produced no effect on immobility time. Even though the false-negative and positive responses made it somewhat difficult to interpret the findings, this study demonstrated that when given before the pretest antidepressants with or without anticholinergic activity seemed to be devoid of impairing the learning process in the test.

  13. Use of the one‐legged hyperextension test and magnetic resonance imaging in the diagnosis of active spondylolysis

    Science.gov (United States)

    Masci, L; Pike, J; Malara, F; Phillips, B; Bennell, K; Brukner, P

    2006-01-01

    Background Active spondylolysis is an acquired lesion in the pars interarticularis and is a common cause of low back pain in the young athlete. Objectives To evaluate whether the one‐legged hyperextension test can assist in the clinical detection of active spondylolysis and to determine whether magnetic resonance imaging (MRI) is equivalent to the clinical gold standard of bone scintigraphy and computed tomography in the radiological diagnosis of this condition. Methods A prospective cohort design was used. Young active subjects with low back pain were recruited. Outcome measures included clinical assessment (one‐legged hyperextension test) and radiological investigations including bone scintigraphy (with single photon emission computed tomography (SPECT)) and MRI. Computed tomography was performed if bone scintigraphy was positive. Results Seventy one subjects were recruited. Fifty pars interarticulares in 39 subjects (55%) had evidence of active spondylolysis as defined by bone scintigraphy (with SPECT). Of these, 19 pars interarticulares in 14 subjects showed a fracture on computed tomography. The one‐legged hyperextension test was neither sensitive nor specific for the detection of active spondylolysis. MRI revealed bone stress in 40 of the 50 pars interarticulares in which it was detected by bone scintigraphy (with SPECT), indicating reduced sensitivity in detecting bone stress compared with bone scintigraphy (p  =  0.001). Conversely, MRI revealed 18 of the 19 pars interarticularis fractures detected by computed tomography, indicating concordance between imaging modalities (p  =  0.345). There was a significant difference between MRI and the combination of bone scintigraphy (with SPECT)/computed tomography in the radiological visualisation of active spondylolysis (p  =  0.002). Conclusions These results suggest that there is a high rate of active spondylolysis in active athletes with low back pain. The one‐legged hyperextension test is not

  14. Energy shift estimation of demand response activation on domestic refrigerators – A field test study

    DEFF Research Database (Denmark)

    Lakshmanan, Venkatachalam; Gudmand-Høyer, Kristian; Marinelli, Mattia

    2014-01-01

    This paper presents a method to estimate the amount of energy that can be shifted during demand response (DR) activation on domestic refrigerator. Though there are many methods for DR activation like load reduction, load shifting and onsite generation, the method under study is load shifting....... Electric heating and cooling equipment like refrigerators, water heaters and space heaters and coolers are preferred for such DR activation because of their energy storing capacity. Accurate estimation of available regulating power and energy shift is important to understand the value of DR activation...... at any time. In this paper a novel method to estimate the available energy shift from domestic refrigerators with only two measurements, namely fridge cool chamber temperature and compressor power consumption is proposed, discussed and evaluated....

  15. A Mobile Application for Easy Design and Testing of Algorithms to Monitor Physical Activity in the Workplace

    Directory of Open Access Journals (Sweden)

    Susanna Spinsante

    2016-01-01

    Full Text Available This paper addresses approaches to Human Activity Recognition (HAR with the aim of monitoring the physical activity of people in the workplace, by means of a smartphone application exploiting the available on-board accelerometer sensor. In fact, HAR via a smartphone or wearable sensor can provide important information regarding the level of daily physical activity, especially in situations where a sedentary behavior usually occurs, like in modern workplace environments. Increased sitting time is significantly associated with severe health diseases, and the workplace is an appropriate intervention setting, due to the sedentary behavior typical of modern jobs. Within this paper, the state-of-the-art components of HAR are analyzed, in order to identify and select the most effective signal filtering and windowing solutions for physical activity monitoring. The classifier development process is based upon three phases; a feature extraction phase, a feature selection phase, and a training phase. In the training phase, a publicly available dataset is used to test among different classifier types and learning methods. A user-friendly Android-based smartphone application with low computational requirements has been developed to run field tests, which allows to easily change the classifier under test, and to collect new datasets ready for use with machine learning APIs. The newly created datasets may include additional information, like the smartphone position, its orientation, and the user’s physical characteristics. Using the mobile tool, a classifier based on a decision tree is finally set up and enriched with the introduction of some robustness improvements. The developed approach is capable of classifying six activities, and to distinguish between not active (sitting and active states, with an accuracy near to 99%. The mobile tool, which is going to be further extended and enriched, will allow for rapid and easy benchmarking of new algorithms based

  16. Overview of the Division 2351 Neutron Generator Test Facility waveform digitizing system. [Explosively activated neutron generators

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, T.C. Jr.

    1978-02-01

    All neutron generator waveforms from units tested at the SLA neutron generator test site are digitized and the digitized data stored in the CDC 6600 tape library for display and analysis using the CDC 6600 computer. The digitizing equipment consists mainly of seven Biomation Model 8100 transient recorders, Digital Equipment Corporation PDP 11/20 computer, RK05 disk, seven-track magnetic tape transport, and appropriate DEC and SLA controllers and interfaces. The PDP 11/20 computer is programmed in BASIC with assembly language drivers. In addition to digitizing waveforms, this equipment is used for other functions such as the automated testing of multiple-operation electronic neutron generators. Although other types of analysis have been done, the largest use of the digitized data has been for various types of graphical displays using the CDC 6600 and either the SD4020 or DX4460 plotters.

  17. Tests on the release of fission and activation products during core meltdown

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, H; Krause, W; Wild, H

    1976-01-01

    The first available results are related to tests in which the release of the main components of the core melt, namely the steel, zircaloy and uranium components, was determined using ThO/sub 2/ crucibles. The release products are dispersed onto the pipe walls of the transport system and the measuring filters which were installed at about 1 m distance from the melt crucibles. Of these, only the precipitates on the filters have been analyzed so far. In the tests under air, the release was clearly dependent on the maximum temperature reached. The release values for Mo and Mn were the highest with 5-10%; uranium with 0.1% on the other hand, was the lowest. In a steam atmosphere over the melt, the analysis of the filter precipitates for all elements gave considerably lower values than with the tests in air.

  18. Critical tests for determination of microbiological quality and biological activity in commercial vermicompost samples of different origins.

    Science.gov (United States)

    Grantina-Ievina, Lelde; Andersone, Una; Berkolde-Pīre, Dace; Nikolajeva, Vizma; Ievinsh, Gederts

    2013-12-01

    The aim of the present paper was to show that differences in biological activity among commercially produced vermicompost samples can be found by using a relatively simple test system consisting of microorganism tests on six microbiological media and soilless seedling growth tests with four vegetable crop species. Significant differences in biological properties among analyzed samples were evident both at the level of microbial load as well as plant growth-affecting activity. These differences were mostly manufacturer- and feedstock-associated, but also resulted from storage conditions of vermicompost samples. A mature vermicompost sample that was produced from sewage sludge still contained considerable number of Escherichia coli. Samples from all producers contained several potentially pathogenic fungal species such as Aspergillus fumigatus, Pseudallescheria boidii, Pseudallescheria fimeti, Pseudallescheria minutispora, Scedosporium apiospermum, Scedosporium prolificans, Scopulariopsis brevicaulis, Stachybotrys chartarum, Geotrichum spp., Aphanoascus terreus, and Doratomyces columnaris. In addition, samples from all producers contained plant growth-promoting fungi from the genera Trichoderma and Mortierella. The described system can be useful both for functional studies aiming at understanding of factors affecting quality characteristics of vermicompost preparations and for routine testing of microbiological quality and biological activity of organic waste-derived composts and vermicomposts.

  19. [Application of locomotor activity test to evaluate functional injury after global cerebral ischemia in C57BL/6 mice].

    Science.gov (United States)

    Zhang, Li-quan; Xu, Jia-ni; Wang, Zhen-zhen; Zeng, Li-jun; Ye, Yi-lu; Zhang, Wei-ping; Wei, Er-qing; Zhang, Qi

    2014-05-01

    To evaluate the application of locomotor activity test in functional injury after global cerebral ischemia (GCI) in C57BL/6 mice. GCI was induced by bilateral carotid arteries occlusion for 30 min in C57BL/6 mice. Mice were divided into sham group, GCI group and minocycline group. Saline or minocycline (45 mg/kg) was i.p. injected once daily for 6 d after ischemia. At Day 6 after ischemia, locomotor activity was recorded for 1 h in open field test. Total distance, central distance, central distance ratio, periphery distance, periphery distance ratio, central time and periphery time were used to evaluate the behavior characteristics of locomotor activity in C57BL/6 mice after ischemia. The survival neuron density was detected by Nissl staining in hippocampus, cortex and striatum. Compared with sham group, total distance, central distance and central time increased and periphery time decreased in C57BL/6 mice after GCI (PsLocomotor activity in open field test can objectively evaluate the behavior injury after GCI in mice. Central distance and central time can be used as indexes of quantitative assessment.

  20. Muscular Activity and Fatigue in Lower-Limb and Trunk Muscles during Different Sit-To-Stand Tests.

    Directory of Open Access Journals (Sweden)

    Cristina Roldán-Jiménez

    Full Text Available Sit-to-stand (STS tests measure the ability to get up from a chair, reproducing an important component of daily living activity. As this functional task is essential for human independence, STS performance has been studied in the past decades using several methods, including electromyography. The aim of this study was to measure muscular activity and fatigue during different repetitions and speeds of STS tasks using surface electromyography in lower-limb and trunk muscles. This cross-sectional study recruited 30 healthy young adults. Average muscle activation, percentage of maximum voluntary contraction, muscle involvement in motion and fatigue were measured using surface electrodes placed on the medial gastrocnemius (MG, biceps femoris (BF, vastus medialis of the quadriceps (QM, the abdominal rectus (AR, erector spinae (ES, rectus femoris (RF, soleus (SO and the tibialis anterior (TA. Five-repetition STS, 10-repetition STS and 30-second STS variants were performed. MG, BF, QM, ES and RF muscles showed differences in muscle activation, while QM, AR and ES muscles showed significant differences in MVC percentage. Also, significant differences in fatigue were found in QM muscle between different STS tests. There was no statistically significant fatigue in the BF, MG and SO muscles of the leg although there appeared to be a trend of increasing fatigue. These results could be useful in describing the functional movements of the STS test used in rehabilitation programs, notwithstanding that they were measured in healthy young subjects.

  1. Muscular Activity and Fatigue in Lower-Limb and Trunk Muscles during Different Sit-To-Stand Tests.

    Science.gov (United States)

    Roldán-Jiménez, Cristina; Bennett, Paul; Cuesta-Vargas, Antonio I

    2015-01-01

    Sit-to-stand (STS) tests measure the ability to get up from a chair, reproducing an important component of daily living activity. As this functional task is essential for human independence, STS performance has been studied in the past decades using several methods, including electromyography. The aim of this study was to measure muscular activity and fatigue during different repetitions and speeds of STS tasks using surface electromyography in lower-limb and trunk muscles. This cross-sectional study recruited 30 healthy young adults. Average muscle activation, percentage of maximum voluntary contraction, muscle involvement in motion and fatigue were measured using surface electrodes placed on the medial gastrocnemius (MG), biceps femoris (BF), vastus medialis of the quadriceps (QM), the abdominal rectus (AR), erector spinae (ES), rectus femoris (RF), soleus (SO) and the tibialis anterior (TA). Five-repetition STS, 10-repetition STS and 30-second STS variants were performed. MG, BF, QM, ES and RF muscles showed differences in muscle activation, while QM, AR and ES muscles showed significant differences in MVC percentage. Also, significant differences in fatigue were found in QM muscle between different STS tests. There was no statistically significant fatigue in the BF, MG and SO muscles of the leg although there appeared to be a trend of increasing fatigue. These results could be useful in describing the functional movements of the STS test used in rehabilitation programs, notwithstanding that they were measured in healthy young subjects.

  2. Antioxidant activity test on ambonese banana stem sap (Musa parasidiaca var. sapientum

    Directory of Open Access Journals (Sweden)

    Hendrik Setia Budi

    2015-12-01

    Full Text Available Background: Polymorphonuclear cells (PMN release oxygen free radicals or reactive oxygen species (ROS during inflammation. As a result, ROS level is higher than antioxidant level in our body during oxidative stress leading to prolong inflammation or continuous tissue damage. Indonesia, on the other hand, is a country with various herbal medicines. For instance, ambonese banana (Musa parasidiaca var. sapientum is often used as herbal medicine. Ambonese banana, moreover, has flavonoid, polyphenol, tannin, and saponin as antioxidants to reduce free radicals by transferring their hydrogen atom. Medicine used to reduce the impact of free radicals is known as antioxidant. Antioxidant is proved to accelerate wound healing. Purpose: This research aims to analyze the effects of the antioxidant activity of Ambonese banana stem sap extract. Method: Antioxidant activities in this research were examined with 1,1-Diphenyl-2-picryl-hidrazyl (DPPH method by reacting with stable radical compounds. Spectrophotometry with a wavelength of 517 nm was used to measure absorption results shown in purple. The absorption results then were calculated by IC50 reduction activity. Result: There were significant differences of Ambonese banana stem sap antioxidant activity (p50%. Conclusion: Ambonese banana stem sap extract has antioxidant activities.

  3. Prenatal ethanol exposure alters steroidogenic enzyme activity in newborn rat testes.

    Science.gov (United States)

    Kelce, W R; Rudeen, P K; Ganjam, V K

    1989-10-01

    We have examined the in utero effects of ethanol exposure on testicular steroidogenesis in newborn male pups. Pregnant Sprague-Dawley rats were fed a liquid ethanol diet (35% ethanol-derived calories), a pair-fed isocaloric liquid diet, or a standard laboratory rat chow and water diet beginning on Day 12 of gestation and continuing through parturition. Although there were no significant differences in the enzymatic activity of 5-ene-3 beta-hydroxysteroid dehydrogenase/isomerase or C17,20-lyase, the enzymatic activity of 17 alpha-hydroxylase was significantly (p less than 0.01) reduced (i.e., approximately 36%) in the ethanol-exposed pups compared to those from the pair-fed and chow treatment groups. This lesion in testicular steroidogenic enzyme activity in newborn male pups exposed to alcohol in utero was transient as 17 alpha-hydroxylase activity from the ethanol-exposed animals returned to control levels by postnatal Day 20 and remained at control levels through adulthood (postnatal Day 60). These data suggest that the suppression of the perinatal testosterone surge in male rats exposed to alcohol in utero and the associated long term demasculinizing effects of prenatal ethanol exposure might be the result of reduced testicular steroidogenic enzyme activity in the perinatal animal.

  4. Development of a versatile readout and test system and characterization of a capacitively coupled active pixel sensor

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, Jens; Gonella, Laura; Hemperek, Tomasz; Hirono, Toko; Huegging, Fabian; Krueger, Hans; Wermes, Norbert [Institute of Physics, University of Bonn, Bonn (Germany); Peric, Ivan [Karlsruher Institut fuer Technologie, Karlsruhe (Germany); Collaboration: ATLAS-Collaboration

    2015-07-01

    With the availability of high voltage and high resistivity CMOS processes, active pixel sensors are becoming increasingly interesting for radiation detection in high energy physics experiments. Although the pixel signal-to-noise ratio and the sensor radiation tolerance were improved, active pixel sensors cannot yet compete with state-of-the-art hybrid pixel detector in a high radiation environment. Hence, active pixel sensors are possible candidates for the outer tracking detector in HEP experiments where production cost plays a role. The investigation of numerous prototyping steps and different technologies is still ongoing and requires a versatile test and readout system, which will be presented in this talk. A capacitively coupled active pixel sensor fabricated in AMS 180 nm high voltage CMOS process is investigated. The sensor is designed to be glued to existing front-end pixel readout chips. Results from the characterization are presented in this talk.

  5. Extracurricular activities: Investigating the affects of participation-nonparticipation on the Georgia High School Science Graduation Test

    Science.gov (United States)

    Moran, Ray A.

    Student achievement research suggests that participation in extracurricular activities has a positive impact on the academic and developmental outcomes for adolescents. Specifically, several studies reported that adolescents who participate in extra-curricular activities are more likely to experience increases in academic achievement, self-esteem, high school graduation rates, and pro-social behaviors. On the other hand, there is research suggesting that participation in extracurricular activities may distract students from their academic pursuits. The state of Georgia requires all eleventh grade students to participate in the Georgia High School Graduation Test (GHSGT). The GHSGT consists of five separate tests that include (a) English/language arts, (b) math, (c) writing, (d) social studies, and (e) science. Each comprehensive exam is worth 600 points. A high school diploma will be awarded if the student scores at least 500 points on each individual exam. Further, review of student outcomes on the GHSGT revealed that first-time test takers were failing the science portion of the test at a greater percentage than any other subject on the GHSGT. Specifically, the Governor's Office of Student Achievement (GOSA) reported that from 2002 through 2004, a total of 70,451 students or 30.3% of students that were first-time test takers failed the science portion of the GHSGT. As a result, investigating factors that potentially could increase student achievement in science became the impetus for this study. In particular, this study examined the relationships between the levels of student participation in school sponsored extracurricular activities in relation to the level of student achievement in the area of science.

  6. Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD.

    Science.gov (United States)

    Souza, Gérson F; Moreira, Graciane L; Tufanin, Andréa; Gazzotti, Mariana R; Castro, Antonio A; Jardim, José R; Nascimento, Oliver A

    2017-08-01

    The Glittre activities of daily living (ADL) test is supposed to evaluate the functional capacity of COPD patients. The physiological requirements of the test and the time taken to perform it by COPD patients in different disease stages are not well known. The objective of this work was to compare the metabolic, ventilatory, and cardiac requirements and the time taken to carry out the Glittre ADL test by COPD subjects with mild, moderate, and severe disease. Spirometry, Medical Research Council questionnaire, cardiopulmonary exercise test, and 2 Glittre ADL tests were evaluated in 62 COPD subjects. Oxygen uptake (V̇ O 2 ), carbon dioxide production, pulmonary ventilation, breathing frequency, heart rate, S pO 2 , and dyspnea were analyzed before and at the end of the tests. Maximum voluntary ventilation, Glittre peak V̇ O 2 /cardiopulmonary exercise test (CPET) peak V̇ O 2 , Glittre V̇ E /maximum voluntary ventilation, and Glittre peak heart rate/CPET peak heart rate ratios were calculated to analyze their reserves. Subjects carried out the Glittre ADL test with similar absolute metabolic, ventilatory, and cardiac requirements. Ventilatory reserve decreased progressively from mild to severe COPD subjects ( P reserve than the mild and moderate subjects ( P = .006 and P = .043, respectively) and significantly lower Glittre peak heart rate/CPET peak heart rate than mild subjects ( P = .01). Time taken to carry out the Glittre ADL test was similar among the groups ( P = .82 for GOLD 1 vs GOLD 2, P = .19 for GOLD 1 vs GOLD 3, and P = .45 for GOLD 2 vs GOLD 3). As the degree of air-flow obstruction progresses, the COPD subjects present significant lower ventilatory reserve to perform the Glittre ADL test. In addition, metabolic and cardiac reserves may differentiate the severe subjects. These variables may be better measures to differentiate functional performance than Glittre ADL time. Copyright © 2017 by Daedalus Enterprises.

  7. The ACTH4–9 analog ORG 2766 ‘normalizes’ the changes in motor activities of rats elicited by housing and test conditions

    NARCIS (Netherlands)

    Wolterink, G.; Ree, J.M. van

    1987-01-01

    Motor activities of rats were decreased by short-term (7 days) social isolation as well as by intense light test conditions. The ACTH4-9 analog ORG 2766, s.c. administered 50 min before testing, dose-dependently decreased the high motor activities of group-housed housed rats tested under low light

  8. Impact of Diabetes Type 1 in Children on Autonomic Modulation at Rest and in Response to the Active Orthostatic Test.

    Science.gov (United States)

    Giacon, Thais Roque; Vanderlei, Franciele Marques; Christofaro, Diego Giulliano Destro; Vanderlei, Luiz Carlos Marques

    2016-01-01

    Cardiovascular autonomic neuropathy is one of the most common complications of diabetes mellitus type 1 (DM1), of which one of the first subclinical manifestations is changes in heart rate variability (HRV). Thus, analysis of HRV associated with the autonomic active orthostatic test is important in this population. To analyze the autonomic modulation responses induced by the implementation of the active orthostatic test, in children with DM1, and study the autonomic modulation by means of HRV indices. Data of 35 children were analyzed, of both sexes, aged between 7 and 15 years, who were divided into two groups: Diabetic (n = 16) and Control (n = 19). The following variables were collected initially: weight, height, body fat percentage, heart rate, blood pressure and casual blood glucose. Subsequently, for analysis of autonomic modulation, the beat-to-beat heart rate was captured by a heart rate monitor in the supine position for 30 minutes and after 10 minutes standing during performance of the active orthostatic test. HRV indices were calculated in the time and frequency domains. For data analysis, covariance analysis was used to compare groups and ANOVA for repeated measures to compare the effects of the active orthostatic test. These data were adjusted for age, sex, ethnicity, body fat percentage and casual blood glucose, with a 5% significance level. The results suggested that diabetic children at rest present a decrease in SDNN (50.4 vs. 75.2), rMSSD (38.7 vs 57.6) and LF [ms2] (693.6 vs 1874.6). During the active orthostatic test the children in both groups demonstrated a reduction in SDNN, RMSSD and LF [ms2] compared to the resting position, and this response was less pronounced in the diabetic group. We conclude that regardless of age, sex, ethnicity, body fat percentage and casual blood glucose, performing the active orthostatic test promoted increased sympathetic modulation and reduced parasympathetic modulation in both groups, and this response was less

  9. Impact of Diabetes Type 1 in Children on Autonomic Modulation at Rest and in Response to the Active Orthostatic Test.

    Directory of Open Access Journals (Sweden)

    Thais Roque Giacon

    Full Text Available Cardiovascular autonomic neuropathy is one of the most common complications of diabetes mellitus type 1 (DM1, of which one of the first subclinical manifestations is changes in heart rate variability (HRV. Thus, analysis of HRV associated with the autonomic active orthostatic test is important in this population.To analyze the autonomic modulation responses induced by the implementation of the active orthostatic test, in children with DM1, and study the autonomic modulation by means of HRV indices.Data of 35 children were analyzed, of both sexes, aged between 7 and 15 years, who were divided into two groups: Diabetic (n = 16 and Control (n = 19. The following variables were collected initially: weight, height, body fat percentage, heart rate, blood pressure and casual blood glucose. Subsequently, for analysis of autonomic modulation, the beat-to-beat heart rate was captured by a heart rate monitor in the supine position for 30 minutes and after 10 minutes standing during performance of the active orthostatic test. HRV indices were calculated in the time and frequency domains. For data analysis, covariance analysis was used to compare groups and ANOVA for repeated measures to compare the effects of the active orthostatic test. These data were adjusted for age, sex, ethnicity, body fat percentage and casual blood glucose, with a 5% significance level.The results suggested that diabetic children at rest present a decrease in SDNN (50.4 vs. 75.2, rMSSD (38.7 vs 57.6 and LF [ms2] (693.6 vs 1874.6. During the active orthostatic test the children in both groups demonstrated a reduction in SDNN, RMSSD and LF [ms2] compared to the resting position, and this response was less pronounced in the diabetic group.We conclude that regardless of age, sex, ethnicity, body fat percentage and casual blood glucose, performing the active orthostatic test promoted increased sympathetic modulation and reduced parasympathetic modulation in both groups, and this response

  10. Phytochemical isolation of compounds from Sceletium tortuosum and activity testing against Plasmodium falciparum

    Directory of Open Access Journals (Sweden)

    Itumeleng I. Setshedi

    2012-06-01

    Full Text Available Malaria is a major health care problem in tropical regions due to the increasing resistance of Plasmodium falciparum against widely available antimalarial drugs. Traditional societies relied on medicinal plants to treat parasitic infections. As a result, drugs like quinine and artemisinin were isolated from herbs and barks (Varughese et al. 2010. Sceletium tortuosum has been used as medicine for social and spiritual purposes by San hunter gatherers and Khoi pastoralists. Sceletium tortuosum is rich in alkaloids, one of the important classes of natural product producing treatment for parasitic infections (Kayser et al. 2002. Laboratory preparation of extracts of fresh S. tortuosum plant material was conducted mimicking traditional methods of preparation using organic solvents. Mesembrine was isolated from a methanol extract using conventional column chromatography. Sixteen extracts and mesembrine were evaluated for antiplasmodium activity using a plasmodium lactate dehydrogenase culture sensitivity assay with chloroquine as reference drug. Of the sixteen extracts, four showed activity against P. falciparum with IC50 ranging between 1.47 µg/mL and 7.32 µg/mL. Extracts prepared from stored material at -20 °C showed no antiplasmodium activity. The four originally active extracts were re-screened six months later, but the antimalarial activity could not be reproduced. To determine discrepancy in biological results, chemical profiling of the extracts was done using high performance liquid chromatography technique. Differences were observed in the profiles of the active extracts when compared to those of stored plant material. The instability of plant constituents observed could be a result of plant storage suggesting that the plant is best used when fresh.

  11. HIV Risk Behavior and Access to Services: What Predicts HIV Testing among Heterosexually Active Homeless Men?

    Science.gov (United States)

    Wenzel, Suzanne L.; Rhoades, Harmony; Tucker, Joan S.; Golinelli, Daniela; Kennedy, David P.; Zhou, Annie; Ewing, Brett

    2012-01-01

    HIV is a serious epidemic among homeless persons, where rates of infection are estimated to be three times higher than in the general population. HIV testing is an effective tool for reducing HIV transmission and for combating poor HIV/AIDS health outcomes that disproportionately affect homeless persons, however, little is known about the HIV…

  12. Protease activity measurement in milk as a diagnostic test for clinical mastitis in dairy cows

    NARCIS (Netherlands)

    Koop, G.; van Werven, T.; Roffel, S.; Hogeveen, H.; Nazmi, K.; Bikker, F.J.

    2015-01-01

    Due to the increasing use of automated milking systems, automated detection of clinical mastitis is becoming more important. Various in- or on-line diagnostic tests are in use, but generally suffer from false mastitis alerts. In this study, we explored a new diagnostic approach based on measurement

  13. SUPERFUND TREATABILITY CLEARINGHOUSE: INCINERATION TEST OF EXPLOSIVES CONTAMINATED SOILS AT SAVANNA ARMY DEPOT ACTIVITY, SAVANNA, ILLINOIS

    Science.gov (United States)

    The primary objective of these tests was to demonstrate the effectiveness of incineration as a decontamination method for explosives contaminated sails. A pilot-scale rotary kiln incinerator, manufactured by ThermAll, Inc., was used to treat both sandy and clayey...

  14. Leak testing plan for the Oak Ridge National Laboratory liquid low- level waste system (active tanks)

    International Nuclear Information System (INIS)

    Douglas, D.G.; Wise, R.F.; Starr, J.W.; Maresca, J.W. Jr.

    1992-06-01

    A leak testing plan for a portion of the Liquid Low-Level Waste (LLLW) system at the Oak Ridge National Laboratory (ORNL) is provided in the two volumes that form this document. This plan was prepared in response to the requirements of the Federal Facilities Agreement (FFA) between the US Department of Energy and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC). The effective date of this agreement was 1 January 1992. The LLLW system is an interconnected complex of tanks and pipelines. The FFA distinguishes four different categories of tank and pipeline systems within this complex: new systems (Category A), doubly contained systems (Category B), singly contained systems (Category C), and inactive systems (Category D). The FFA's specific requirements for leak testing of the Category C systems is addressed in this plan. The plan also addresses leak testing of the Category B portions of the LLLW system. Leak testing of the Category B components was brought into the plan to supplement the secondary containment design demonstration effort that is under way for these components

  15. 77 FR 10509 - Agency Information Collection Activities; Proposed Collection; Comment Request; Drug Testing for...

    Science.gov (United States)

    2012-02-22

    ... that may potentially affect communities and the surrounding environment. Releases may be accidental... may be responsible for testing their employees for the use of marijuana, cocaine, opiates.... Respondents/Affected Entities: EPA contractor employees who work at sensitive sites. Estimated Number of...

  16. Toxicity of compounds with endocrine activity in the OECD 421 reproductive toxicity screening test

    NARCIS (Netherlands)

    Piersma AH; Verhoef A; Elvers LH; Wester PW; LEO; LPI

    1998-01-01

    The issue of endocrine disruption has, in view of human risk assessment, raised the question on whether more sensitive test methods are needed to detect the reproductive toxic properties of xenobiotic compounds with endocrine properties. We studied six known and alleged endocrine disruptors in an

  17. Critical Evaluation of Animal Alternative Tests for the Identification of Endocrine Active Substances, oral presentation

    Science.gov (United States)

    In the past 20 years, considerable progress in animal alternatives accompanied by advances in the toxicological sciences and new emphases on aquatic vertebrates has appeared. A significant amount of current research is targeted to evaluate alternative test methods that may reduce...

  18. Supplemental Immobilization of Hanford Low-Activity Waste: Cast Stone Augmented Formulation Matrix Tests

    International Nuclear Information System (INIS)

    Cozzi, A.; Crawford, C.; Fox, K.; Hansen, E.; Roberts, K.

    2015-01-01

    More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy's (DOE's) Hanford Site in Washington State. The HLW will be vitrified in the HLW facility for ultimate disposal at an offsite federal repository. A portion (~35%) of the LAW will be vitrified in the LAW vitrification facility for disposal onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize all of the wastes destined for those facilities. However, a second facility will be needed for the expected volume of LAW requiring immobilization. Cast Stone, a cementitious waste form, is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with the waste acceptance criteria for the disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. A testing program was developed in fiscal year (FY) 2012 describing in detail the work needed to develop and qualify Cast Stone as a waste form for the solidification of Hanford LAW. A statistically designed test matrix was used to evaluate the effects of key parameters on the properties of the Cast Stone as it is initially prepared and after curing. For the processing properties, the water-to-dry-blend mix ratio was the most significant parameter in affecting the range of values observed for each property. The single shell tank (SST) Blend simulant also showed differences in measured properties compared to the other three simulants tested. A review of the testing matrix and results indicated that an additional set of tests would be beneficial to improve the understanding of the impacts noted in the

  19. Supplemental Immobilization of Hanford Low-Activity Waste: Cast Stone Augmented Formulation Matrix Tests

    Energy Technology Data Exchange (ETDEWEB)

    Cozzi, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Crawford, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fox, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hansen, E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Roberts, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-07-20

    More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in Washington State. The HLW will be vitrified in the HLW facility for ultimate disposal at an offsite federal repository. A portion (~35%) of the LAW will be vitrified in the LAW vitrification facility for disposal onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize all of the wastes destined for those facilities. However, a second facility will be needed for the expected volume of LAW requiring immobilization. Cast Stone, a cementitious waste form, is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with the waste acceptance criteria for the disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. A testing program was developed in fiscal year (FY) 2012 describing in detail the work needed to develop and qualify Cast Stone as a waste form for the solidification of Hanford LAW. A statistically designed test matrix was used to evaluate the effects of key parameters on the properties of the Cast Stone as it is initially prepared and after curing. For the processing properties, the water-to-dry-blend mix ratio was the most significant parameter in affecting the range of values observed for each property. The single shell tank (SST) Blend simulant also showed differences in measured properties compared to the other three simulants tested. A review of the testing matrix and results indicated that an additional set of tests would be beneficial to improve the understanding of the impacts noted in the Screening

  20. Mutagenic activity of a fluorinated analog of the beta-adrenoceptor ligand carazolol in the Ames test

    Energy Technology Data Exchange (ETDEWEB)

    Doze, P. E-mail: P.Doze@pet.azg.nl; Elsinga, P.H.; Vries, E.F.J. de; Waarde, A. van; Vaalburg, W

    2000-04-01

    S-1'[{sup 18}F]-Fluorocarazolol (FCAR) is a fluorinated analog of the nonmutagenic beta-blocker carazolol (CAR). In former studies FCAR proved to be suitable for quantification of beta-adrenoceptors in vivo with positron emission tomography (PET). We report here that FCAR displays no acute toxicity in either rats or mice. However, FCAR induces a strong dose-related increase in the number of revertants in the Ames test. We conclude that FCAR yields mutagenic activity as measured by the Ames test.

  1. Current use and acceptability of novel diagnostic tests for active tuberculosis: a worldwide survey

    Directory of Open Access Journals (Sweden)

    Massimo Amicosante

    Full Text Available ABSTRACT Objective: To determine the current use and potential acceptance (by tuberculosis experts worldwide of novel rapid tests for the diagnosis of tuberculosis that are in line with World Health Organization target product profiles. Methods: A multilingual survey was disseminated online between July and November of 2016. Results: A total of 723 individuals from 114 countries responded to the survey. Smear microscopy was the most commonly used rapid tuberculosis test (available to 90.9% of the respondents, followed by molecular assays (available to 70.7%. Only a small proportion of the respondents in middle- and low-income countries had access to interferon-gamma-release assays. Serological and lateral flow immunoassays were used by more than a quarter (25.4% of the respondents. Among the respondents who had access to molecular tests, 46.7% were using the Xpert assay overall, that proportion being higher in lower middle-income countries (55.6% and low-income countries (76.6%. The data also suggest that there was some alignment of pricing for molecular assays. Respondents stated they would accept novel rapid tuberculosis tests if available, including molecular assays (acceptable to 86.0% or biomarker-based serological assays (acceptable to 81.7%. Simple biomarker-based assays were more commonly deemed acceptable in middle- and low-income countries. Conclusions: Second-generation molecular assays have become more widely available in high- and low-resource settings. However, the development of novel rapid tuberculosis tests continues to be considered important by tuberculosis experts. Our data also underscore the need for additional training and education of end users.

  2. Application of the Copenhagen Soccer Test in high-level women players - locomotor activities, physiological response and sprint performance

    DEFF Research Database (Denmark)

    Bendiksen, Mads; Pettersen, Svein Arne; Ingebrigtsen, Jørgen

    2013-01-01

    We evaluated the physiological response, sprint performance and technical ability in various phases of the Copenhagen Soccer Test for Women (CSTw) and investigated whether the locomotor activities of the CSTw were comparable to competitive match-play (CM). Physiological measurements and physical....../technical assessments were performed during CSTw for eleven Norwegian high-level women soccer players. The activity pattern during CSTw and CM was monitored using the ZXY tracking system. No differences were observed between CSTw and CM with regards to total distance covered (10093±94 and 9674±191m), high intensity...

  3. A Test of the Formation Mechanism of the Broad Line Region in Active Galactic Nuclei

    Czech Academy of Sciences Publication Activity Database

    Czerny, B.; Du, P.; Wang, J.-M.; Karas, Vladimír

    2016-01-01

    Roč. 832, č. 1 (2016), 15/1-15/11 ISSN 0004-637X Institutional support: RVO:67985815 Keywords : galaxies * emission lines * active galaxies Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 5.533, year: 2016

  4. Dental Charting. Learning Activities, Unit Tests, Progress Chart, and Work Sheet.

    Science.gov (United States)

    Texas Univ., Austin. Center for Occupational Curriculum Development.

    These materials are part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. These student materials, designed to be used with the Dental Charting Student Manual, consist of learning activities, unit…

  5. Design and experimental tests of a rotary active magnetic regenerator prototype

    DEFF Research Database (Denmark)

    Eriksen, Dan; Engelbrecht, Kurt; Bahl, Christian

    2015-01-01

    A rotary active magnetic regenerator (AMR) prototype with efficiency and compact design as focus points has been designed and built. The main objective is to demonstrate improved efficiency for rotary devices by reducing heat leaks from the environment and parasitic mechanical work losses while...

  6. Workout at work: laboratory test of psychological and performance outcomes of active workstations.

    Science.gov (United States)

    Sliter, Michael; Yuan, Zhenyu

    2015-04-01

    With growing concerns over the obesity epidemic in the United States and other developed countries, many organizations have taken steps to incorporate healthy workplace practices. However, most workers are still sedentary throughout the day--a major contributor to individual weight gain. The current study sought to gather preliminary evidence of the efficacy of active workstations, which are a possible intervention that could increase employees' physical activity while they are working. We conducted an experimental study, in which boredom, task satisfaction, stress, arousal, and performance were evaluated and compared across 4 randomly assigned conditions: seated workstation, standing workstation, cycling workstation, and walking workstation. Additionally, body mass index (BMI) and exercise habits were examined as moderators to determine whether differences in these variables would relate to increased benefits in active conditions. The results (n = 180) showed general support for the benefits of walking workstations, whereby participants in the walking condition had higher satisfaction and arousal and experienced less boredom and stress than those in the passive conditions. Cycling workstations, on the other hand, tended to relate to reduced satisfaction and performance when compared with other conditions. The moderators did not impact these relationships, indicating that walking workstations might have psychological benefits to individuals, regardless of BMI and exercise habits. The results of this study are a preliminary step in understanding the work implications of active workstations. (c) 2015 APA, all rights reserved).

  7. Problems of evaluation of nuclear reactor active zone tubes during pre-irradiation tests

    International Nuclear Information System (INIS)

    Lezinskaya, E.Ya.; Buryak, T.N.

    2004-01-01

    An analysis of standard methods of graine size estimation of basic indexes of austenitic steel and alloys of active area of atomic reactors. It is shown insolvency of standard methods of grain size estimation in the real wares. The suggested method of computer simulation of structures of pipes-shells raped for working aut of modes of heat treatment

  8. Solar Energy Education. Social studies: activities and teacher's guide. Field test edition

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    Solar energy information is made available to students through classroom instruction by way of the Solar Energy Education teaching manuals. In this manual solar energy, as well as other energy sources like wind power, is introduced by performing school activities in the area of social studies. A glossary of energy related terms is included. (BCS)

  9. The influence of periodic increases of human activity on crepuscular and nocturnal mammals: Testing the weekend effect.

    Science.gov (United States)

    Nix, Joshua H; Howell, Ryan G; Hall, Lucas K; McMillan, Brock R

    2018-01-01

    Human recreation can negatively affect wildlife, particularly on weekends when human activity is highest (i.e., the weekend effect). Much of what we understand about the weekend effect is based on research conducted on diurnal species, which have greater temporal overlap with humans. Because nocturnal species generally avoid times when humans are active, they are likely less affected by anthropogenic activity on weekends. Our objective was to test the weekend effect in relation to the degree of nocturnality of mammals in a recreational area. We predicted that as nocturnality increased, the effect of human activity would decrease. To address our objective, we placed 50 remote cameras along the Diamond Fork River in Utah from January to June 2015. We found that three out of the four focal species supported our predictions. Mule deer (crepuscular) reduced activity throughout our entire study area during weekends and avoided campgrounds. Beavers and mountain lions (both nocturnal) did not negatively respond to increased human activity. Raccoons (nocturnal) reduced activity during weekends, but only within campground areas. Our findings indicate that as the temporal overlap increases between wildlife and humans, so does the influence that humans have on wildlife. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. INL Active Interrogation Testing In Support of the GNEP Safeguards Campaign

    International Nuclear Information System (INIS)

    David L. Chichester

    2008-01-01

    Active interrogation, a measurement technique which uses a radiation source to probe materials and generate unique signatures useful for characterizing those materials, is a powerful tool for assaying special nuclear material. Work at Idaho National Laboratory (INL) in the area of active interrogation, using neutron and photon sources, has been under way for many years to develop methods for detecting and quantifying nuclear material for national and homeland security research areas. This research knowledge base is now being extended to address nuclear safeguards and process monitoring issues related to the Global Nuclear Energy Partnership (GNEP). As a first step in this area preliminary scoping studies have been performed to investigate the usefulness of using active neutron interrogation, with a low-power electronic neutron generator, to assay Department of Transportation 6M shipping drums containing uranium oxide fuel rodlets from INL's zero power physics reactor. Using the paired-counting technique during the die-away time period of interrogation, a lower detection limit of approximately 4.2 grams of enriched uranium (40% 235U) was calculated for a 40 minute measurement using a field portable 2.5 MeV neutron source and an array of 16 moderated helium-3 neutron tubes. Future work in this area, including the use of a more powerful neutron source and a better tailored detector array, would likely improve this limit to a much lower level. Further development work at INL will explore the applicability of active interrogation in association with the nuclear safeguards and process monitoring needs of the advanced GNEP facilities under consideration. This work, which will include both analyses and field demonstrations, will be performed in collaboration with colleagues at INL and elsewhere that have expertise in nuclear fuel reprocessing as well as active interrogation and its use for nuclear material analyses

  11. Soil Moisture Active and Passive (SMAP) White-Painted Expanded Polystyrene (EPS) Radome Survivability Test

    Science.gov (United States)

    Mikhaylov, Rebecca; Kwack, Eug; Stegman, Matthew; Dawson, Douglas; Hoffman, Pamela

    2015-01-01

    NASA's SMAP Mission launched in January 2015 into a 685 km near-polar, sun-synchronous orbit. The SMAP instrument architecture incorporates an L-band radar and radiometer which share a common feedhorn and mesh reflector. The instrument rotates about the nadir axis at approximately 15 rpm, thereby providing a conically scanning wide swath antenna beam that is capable of achieving global coverage within three days. The radiometer and its associated electronics have tight thermal stability requirements in order to meet the required surface emittance measurement precision from space. Maintaining the thermal stabilities is quite challenging because the radiometer is located on a spinning platform that can either be in full sunlight or eclipse, and thus exposed to a highly transient environment. Stability requirements were met by integrating a light-weight Expanded Polystyrene (EPS) radome into the design to prevent solar illumination of the feed horn interior. The radome was painted white since the thermo-optical properties of bare sunlit EPS degrade rapidly over the three-year mission. Milling of the EPS and solvent within the white paint created cavities on the EPS surface which may introduce localized hot spots possibly violating the EPS glass transition temperature of 96degC and leading to structural integrity concerns. A three-day thermal test was conducted in a vacuum chamber to verify survivability of the radome during a simulated non-spin fault condition at end of mission. A portable solar simulator illuminated the test article and the beam irradiance was kept nearly constant during the entire 50 hour test, except during the first hour which simulated the expected 79degC on-orbit surface temperature of the radome. The test article survived based on the established pass criteria for three separate metrics: dimensional, optical property, and color. If any hot spots exist locally, they did not cause any observable permanent deformation when compared to pre- and

  12. Test plan for measuring ventilation rates and combustible gas levels in TWRS active catch tanks

    Energy Technology Data Exchange (ETDEWEB)

    NGUYEN, D.M.

    1999-05-20

    The purpose of this test is to provide an initial screening of combustible gas concentrations in catch tanks that currently are operated by Tank Waste Remediation System (TWRS). The data will be used to determine whether or not additional data will be needed for closure of the flammable gas unreviewed safety question for these facilities. This test will involve field measurements of ammonia, organic vapor, and total combustible gas levels in the headspace of the catch tanks. If combustible gas level in a tank exceeds an established threshold, gas samples will be collected in SUMMA canisters for more extensive laboratory analysis. In addition, ventilation rates of some catch tanks will be measured to evaluate removal of flammable gas by air flow through the tanks.

  13. Test plan for measuring ventilation rates and combustible gas levels in RPP active catch tanks

    Energy Technology Data Exchange (ETDEWEB)

    NGUYEN, D.M.

    1999-06-03

    The purpose of this test is to provide an initial screening of combustible gas concentrations in catch tanks that currently are operated by River Protection Project (RPP). The data will be used to determine whether or not additional data will be needed for closure of the flammable gas unreviewed safety question for these facilities. This test will involve field measurements of ammonia, organic vapor, and total combustible gas levels in the headspace of the catch tanks. If combustible gas level in a tank exceeds an established threshold, gas samples will be collected in SUMMA canisters for more extensive laboratory analysis. In addition, ventilation rates of some catch tanks will be measured to evaluate removal of flammable gas by air flow through the tanks.

  14. Ground tests with prototype of CeBr{sub 3} active gamma ray spectrometer proposed for future venus surface missions

    Energy Technology Data Exchange (ETDEWEB)

    Litvak, M.L., E-mail: litvak@mx.iki.rssi.ru [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Sanin, A.B.; Golovin, D.V. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Jun, I. [Jet Propulsion Laboratory, Pasadena, CA (United States); Mitrofanov, I.G. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Shvetsov, V.N.; Timoshenko, G.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Vostrukhin, A.A. [Space Research Institute, RAS, Moscow 117997 (Russian Federation)

    2017-03-11

    The results of a series of ground tests with a prototype of an active gamma-ray spectrometer based on a new generation of scintillation crystal (CeBr{sub 3}) are presented together with a consideration to its applicability to future Venus landing missions. We evaluated the instrument's capability to distinguish the subsurface elemental composition of primary rock forming elements such as O, Na, Mg, Al, Si, K and Fe. Our study uses heritage from previous ground and field tests and applies to the analysis of gamma lines from activation reaction products generated by a pulsed neutron generator. We have estimated that the expected accuracies achieved in this approach could be as high as 1–10% for the particular chemical element being studied.

  15. Development and qualification of functional materials for the EU Test Blanket Modules: Strategy and R and D activities

    Energy Technology Data Exchange (ETDEWEB)

    Zmitko, M., E-mail: milan.zmitko@f4e.europa.eu [Fusion for Energy (F4E), 08019 Barcelona (Spain); Poitevin, Y. [Fusion for Energy (F4E), 08019 Barcelona (Spain); Boccaccini, L., E-mail: lorenzo.boccaccini@inr.fzk.de [Institut Fuer Neutronenphysik und Reaktortechnik, FZK, D-76021 Karlsruhe (Germany); Salavy, J.-F., E-mail: jfsalavy@cea.fr [CEA/Saclay, DEN/DM2S, F-91191 Gif-sur-Yvette (France); Knitter, R., E-mail: regina.knitter@imf.fzk.de [Institut Fuer Materialforschung III, FZK, D-76021 Karlsruhe (Germany); Moeslang, A., E-mail: anton.moeslang@imf.fzk.de [Institut Fuer Materialforschung I, FZK, D-76021 Karlsruhe (Germany); Magielsen, A.J., E-mail: magielsen@nrg.eu [NRG Petten, 1755 ZG Petten (Netherlands); Hegeman, J.B.J. [NRG Petten, 1755 ZG Petten (Netherlands); Laesser, R. [Fusion for Energy (F4E), 08019 Barcelona (Spain)

    2011-10-01

    Europe has developed two reference tritium breeder blankets concepts for a DEMO fusion reactor: the Helium-Cooled Lithium-Lead and the Helium-Cooled Pebble-Bed. Both will be tested in ITER under the form of Test Blanket Modules (TBMs). The paper reviews the current status of development and qualification of the EU TBMs functional materials; i.e. ceramic solid breeder materials, beryllium/beryllides multiplier materials and Lithium-Lead liquid metal breeder material Pb-15.7Li. For each functional material the main functional/performance requirements with key qualification issues, current status of the R and D activities and the EU development strategy are presented. In the development strategy major steps considered are listed pointing out importance of the 'Development/qualification/procurement plan', currently under elaboration, for definition of a roadmap of further activities aiming at delivery of qualified functional materials to be used in the European TBMs in ITER.

  16. Modeling and experimental testing activity of the Voltage Optimization Unit

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Hu, Junjie; Marinelli, Mattia

    In the EUDP project ‘Energy saving by voltage management’ two reports are provided by Technical University of Denmark (DTU) covering the simulation studies and experimental work. The first report presented the simulation results regarding the technical evaluation of on-load tap changers in solving...... and distributed power systems, located at DTU Risø campus. The experimental test validates the control performance of the OLTC transformer and the test indicates that, using remote measurement, the voltage of the system can be kept in a safe operational band. However, the remote measurement implies additional...... cost investments of to the system operator, thus a proactive tap algorithm is developed and tested in this project, relying on local measurements. In addition, we also compared the experimental result with the one simulated in the DigSilent PowerFactory software environment (the software used...

  17. The spectral analysis of motion: An "open field" activity test example

    Directory of Open Access Journals (Sweden)

    Obradović Z.

    2013-01-01

    Full Text Available In this work we have described the new mathematical approach, with spectral analysis of the data to evaluate position and motion in the „„open field““ experiments. The aim of this work is to introduce several new parameters mathematically derived from experimental data by means of spectral analysis, and to quantitatively estimate the quality of the motion. Two original software packages (TRACKER and POSTPROC were used for transforming a video data to a log file, suitable for further computational analysis, and to perform analysis from the log file. As an example, results obtained from the experiments with Wistar rats in the „open field“ test are included. The test group of animals was treated with diazepam. Our results demonstrate that all the calculated parameters, such as movement variability, acceleration and deceleration, were significantly lower in the test group compared to the control group. We believe that the application of parameters obtained by spectral analysis could be of great significance in assessing the locomotion impairment in any kind of motion. [Projekat Ministarstva nauke Republike Srbije, br. III41007 i br. ON174028

  18. Physical activity and 5-year changes in physical performance tests and bone mineral density in postmenopausal women: the Yokogoshi Study.

    Science.gov (United States)

    Kitamura, Kaori; Nakamura, Kazutoshi; Kobayashi, Ryosaku; Oshiki, Rieko; Saito, Toshiko; Oyama, Mari; Takahashi, Shunsuke; Nishiwaki, Tomoko; Iwasaki, Masanori; Yoshihara, Akihiro

    2011-09-01

    The effect of physical activity on musculoskeletal health in older adults is not completely understood. The aim of this study was to determine the relationship between physical activity and 5-year changes in physical performance tests and bone mineral density (BMD) in postmenopausal women. The design was a 5-year cohort study. Subjects were 507 women (55-74 years old) living in a rural community in Japan. Physical activity assessed included housework, farm work, and moderate leisure-time physical activity within the previous week. Measurements at baseline included handgrip strength, walking time (timed "Up & Go" test) and BMD of the femoral neck and vertebrae. Five-year changes in these measures (outcome variables) were compared among groups with different levels of physical activity by analysis of covariance. Women who did not do housework performed worse in changes in handgrip strength (difference=2.22 kg, P=0.0201) and worse in changes in the walking time (difference=0.54 s, P=0.0072) than those who did housework alone. Women who spent at least 9h per week (median=24) doing farm work performed better in changes in handgrip strength (difference=0.28 kg, P=0.0334), but worse in changes in the walking time (difference=0.66 s, Pwork. However, leisure-time activity was not associated with changes in any outcome variable, and none of the physical activities predicted BMD changes. Engaging in housework and farm work are determinants of physical function in postmenopausal women, which may help them maintain independence in daily living. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Prediction of VO[subscript 2]max in Children and Adolescents Using Exercise Testing and Physical Activity Questionnaire Data

    Science.gov (United States)

    Black, Nate E.; Vehrs, Pat R.; Fellingham, Gilbert W.; George, James D.; Hager, Ron

    2016-01-01

    Purpose: The purpose of this study was to evaluate the use of a treadmill walk-jog-run exercise test previously validated in adults and physical activity questionnaire data to estimate maximum oxygen consumption (VO[subscript 2]max) in boys (n = 62) and girls (n = 66) aged 12 to 17 years old. Methods: Data were collected from Physical Activity…

  20. Metric properties of the "timed get up and go- modified version" test, in risk assessment of falls in active women.

    Science.gov (United States)

    Alfonso Mora, Margareth Lorena

    2017-03-30

    To analyse the metric properties of the Timed Get up and Go-Modified Version Test (TGUGM), in risk assessment of falls in a group of physically active women. A sample was constituted by 202 women over 55 years of age, were assessed through a crosssectional study. The TGUGM was applied to assess their fall risk. The test was analysed by comparison of the qualitative and quantitative information and by factor analysis. The development of a logistic regression model explained the risk of falls according to the test components. The TGUGM was useful for assessing the risk of falls in the studied group. The test revealed two factors: the Get Up and the Gait with dual task . Less than twelve points in the evaluation or runtimes higher than 35 seconds was associated with high risk of falling. More than 35 seconds in the test indicated a risk fall probability greater than 0.50. Also, scores less than 12 points were associated with a delay of 7 seconds more in the execution of the test ( p = 0.0016). Factor analysis of TGUGM revealed two dimensions that can be independent predictors of risk of falling: The Get up that explains between 64% and 87% of the risk of falling, and the Gait with dual task, that explains between 77% and 95% of risk of falling.

  1. A thermal active restrained shrinkage ring test to study the early age concrete behaviour of massive structures

    International Nuclear Information System (INIS)

    Briffaut, M.; Benboudjema, F.; Torrenti, J.M.; Nahas, G.

    2011-01-01

    In massive concrete structures, cracking may occur during hardening, especially if autogenous and thermal strains are restrained. The concrete permeability due to this cracking may rise significantly and thus increase leakage (in tank, nuclear containment...) and reduce the durability. The restrained shrinkage ring test is used to study the early age concrete behaviour (delayed strains evolution and cracking). This test shows, at 20 o C and without drying, for a concrete mix which is representative of a French nuclear power plant containment vessel (w/c ratio equal to 0.57), that the amplitude of autogenous shrinkage (about 40 μm/m for the studied concrete mix) is not high enough to cause cracking. Indeed, in this configuration, thermal shrinkage is not significant, whereas this is a major concern for massive structures. Therefore, an active test has been developed to study cracking due to restrained thermal shrinkage. This test is an evolution of the classical restrained shrinkage ring test. It allows to take into account both autogenous and thermal shrinkages. Its principle is to create the thermal strain effects by increasing the temperature of the brass ring (by a fluid circulation) in order to expand it. With this test, the early age cracking due to restrained shrinkage, the influence of reinforcement and construction joints have been experimentally studied. It shows that, as expected, reinforcement leads to an increase of the number of cracks but a decrease of crack widths. Moreover, cracking occurs preferentially at the construction joint.

  2. Tracer tests to determine the impact of industrial activities on groundwater

    International Nuclear Information System (INIS)

    Gaspar, R.D.

    1995-01-01

    The drinking water supply from drains of Iasi town is vulnerable to pollution because of the human activities developed in the supply area. To assess the vulnerability, the transfer functions of pollutants were determined using activable tracer and fluorescent dyes. Tracer techniques have been applied in very permeable sediments and in surface waters for the determination of the dynamic parameters of groundwater movements such as flow vectors and dispersion. To determine the residence time distribution of the pollutants, the mathematical models for surface water pollution and an axial dispersion model for the porous medium between the pollution source and catchment were used. Tracer techniques also allowed the determination of water losses under the drain. (author) 7 figs., 1 tab., 12 refs

  3. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  4. Degradation of polyvinyl chloride (PVC) / hydrolyzed collagen (HC) blends active sludge test.

    Science.gov (United States)

    Agafiţei, Gabriela-Elena; Pascu, Mihaela; Cazacu, Georgeta; Vasile, Cornelia

    2008-01-01

    Biodegradable polymers represent a solution for the environment protection: they decrease the landfill space, by declining the petrochemical sources, and offer also an alternative solution for the recycling. The behavior during degradation in the presence of active sludge of some polyvinyl chloride (PVC) based blends with variable content of hydrolyzed collagen (HC) has been followed. Some samples were subjected to UV irradiation, for 30 hours. The modifications induced in the environment by the polymer systems (pH variation, bacterial composition), as well as the changes of the properties of the blends (weight losses, aspect etc.) were studied. During the first moments of degradation in active sludge, all the samples absorbed water, behavior which favored the biodegradation. The bacteriological analysis of the sludge indicates the presence of some microbiological species. Generally, the populations of microorganisms decrease, excepting the sulphito-reducing anaerobic bacteria, the actinomycetes and other anaerobic bacteria. PVC/HC blends are degraded with a significant rate in active sewage sludge. More susceptible for the degradation are the UV irradiated blends. After the migration of the components with a small molecular mass in the environment, the natural polymer is degraded. The degradation effect increases with the content in the natural polymer.

  5. Enhancing activated-peroxide formulations for porous materials: Test methods and results

    Energy Technology Data Exchange (ETDEWEB)

    Krauter, Paula [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Tucker, Mark D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Tezak, Matthew S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Boucher, Raymond [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2012-12-01

    During an urban wide-area incident involving the release of a biological warfare agent, the recovery/restoration effort will require extensive resources and will tax the current capabilities of the government and private contractors. In fact, resources may be so limited that decontamination by facility owners/occupants may become necessary and a simple decontamination process and material should be available for this use. One potential process for use by facility owners/occupants would be a liquid sporicidal decontaminant, such as pHamended bleach or activated-peroxide, and simple application devices. While pH-amended bleach is currently the recommended low-tech decontamination solution, a less corrosive and toxic decontaminant is desirable. The objective of this project is to provide an operational assessment of an alternative to chlorine bleach for low-tech decontamination applications activated hydrogen peroxide. This report provides the methods and results for activatedperoxide evaluation experiments. The results suggest that the efficacy of an activated-peroxide decontaminant is similar to pH-amended bleach on many common materials.

  6. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn's Disease.

    Science.gov (United States)

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-04-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn's disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-valuewomen with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease.

  7. Introduction of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) and preparatory activities for its entry into force

    Energy Technology Data Exchange (ETDEWEB)

    Tani, Hiroshi [Japan Atomic Energy Research Inst., Mutsu Establishment, Mutsu, Aomori (Japan)

    2001-03-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is a very important treaty, not only for Japan but also for the world, because it prohibits any nuclear weapon test explosion or any other nuclear explosion anywhere in the world. The treaty however will not enter into force until it has been signed and ratified by all the 44 states listed in Annex 2 to the treaty. Many efforts to facilitate the treaty's early entry into force are being done by many countries and many international organizations. As one of result of these efforts, a Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization had be established at a meeting of State Signatories on 19 November 1996, and the Commission started activities to establish global verification regime of the treaty and to prepare for its entry into force. Under the CTBT activities, the Japan Atomic Energy Research Institute (JAERI) is expected to play an important role as supporter for the Japanese Government, especially in a field of an International Monitoring System (IMS). However, there is no appropriate guide book on the CTBT for JAERI staff at present. This report provides some introduction of the CTBT regime and preparatory activities for its entry into force. Only open source information is used for making the report. If anyone need more detail information, it should be asked to contact competent authorities. (author)

  8. Application of the Copenhagen Soccer Test in high-level women players - locomotor activities, physiological response and sprint performance.

    Science.gov (United States)

    Bendiksen, Mads; Pettersen, Svein Arne; Ingebrigtsen, Jørgen; Randers, Morten B; Brito, João; Mohr, Magni; Bangsbo, Jens; Krustrup, Peter

    2013-12-01

    We evaluated the physiological response, sprint performance and technical ability in various phases of the Copenhagen Soccer Test for Women (CSTw) and investigated whether the locomotor activities of the CSTw were comparable to competitive match-play (CM). Physiological measurements and physical/technical assessments were performed during CSTw for eleven Norwegian high-level women soccer players. The activity pattern during CSTw and CM was monitored using the ZXY tracking system. No differences were observed between CSTw and CM with regards to total distance covered (10093±94 and 9674±191m), high intensity running (1278±67 and 1193±115m) or sprinting (422±55 and 372±46m) (p>.05). During CSTw, average HR was 85±2%HRmax with 35±2% playing time >90%HRmax. Blood lactate increased (ptest. Blood glucose was 5.4±0.3mM at rest and remained unaltered during CSTw. Sprint performance (2×20m) decreased (plocomotor activities during CSTw were comparable to that of high-level competitive match-play. The physiological demands of the CSTw were high, with no changes in heart rate, blood lactate or technical performance during the test, but a lowered sprint performance towards the end of the test. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Evaluating the biodegradability and effects of dispersed oil using Arctic test species and conditions: phase 2 activities

    Energy Technology Data Exchange (ETDEWEB)

    MacFarlin, Kelly M.; Perkins, Robert A. [University of Alaska Fairbanks (United States)], email: raperkins@alaska.edu; Gardiner, William W.; Word, Jack D. [NewFields NorthWest (United States)

    2011-07-01

    In the event of a marine oil spill, managers have to make correct and rapid decisions, weighing a number of possibilities, which include natural attenuation, mechanical recovery, in situ burning, and/or chemical dispersion. To do this, the relative toxicity of physically and chemically dispersed fresh oil and the rates of biodegradation for fresh and weathered oil need to be understood in advance. A joint industry program was established in 2008 to research and discuss these areas. Phase 1 activities included determining the species relevant to the Beaufort and Chukchi Sea ecosystems, creating and setting up a toxicity and biodegradation laboratory with a cold room in Barrow, Alaska, developing collection and culture methods for test organisms, and developing toxicity and biodegradation test protocols. The second phase of this now completed research is discussed in this paper. It consisted of toxicity testing of the local environmentally significant species, the copepod (C. glacialis), Arctic cod (B. saida), and larval sculpin (Myoxocephalus sp.).

  10. Accuracy statistics in predicting Independent Activities of Daily Living (IADL) capacity with comprehensive and brief neuropsychological test batteries.

    Science.gov (United States)

    Karzmark, Peter; Deutsch, Gayle K

    2018-01-01

    This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.

  11. Effects of a whole body vibration training program on strength, power, and functional tests in the physically active elderly

    Directory of Open Access Journals (Sweden)

    Renata Gonçalves da Silva

    2009-04-01

    Full Text Available The aim of this study was to investigate the effect of a whole body vibration training program on knee extensor isokinetic peak torque, average power, and functional tests in the physically active elderly. Forty-seven subjects, who participated in a training program for the elderly, were recruited. The subjects were divided into two groups: whole body vibration group (WBV (n=24, 70.7±5.8 years, 62.7±12.3 kg and 155.9±8.0 cm and control group (n=23. 70.0±5.7 years, 65.3±10.7 kg and 157.9±6.6 cm. The WBS group underwent whole body vibration exercise and their regular training program for 13 weeks, 2 times per week, whereas the control group performed the regular training program only. Whole body vibration training was not effective in increasing isokinetic peak torque, average power, or performance in the functional tests. On the other hand, the regular training program was effective in increasing elbow flexor strength endurance, distance covered in the 6-min walk test, and speed in the timed up and go test. The results suggest that vibration training is not effective in modifying functionality or muscle strength and power in the physically active elderly.

  12. Determination of hemisphere dominance for language: comparison of frontal and temporal fMRI activation with intracarotid amytal testing

    International Nuclear Information System (INIS)

    Spreer, J.; Arnold, S.; Ziyeh, S.; Klisch, J.; Schumacher, M.; Quiske, A.; Altenmueller, D.; Schulze-Bonhage, A.; Wohlfarth, R.; Steinhoff, B.J.; Herpers, M.; Kassubek, J.; Honegger, J.

    2002-01-01

    The reliability of frontal and temporal fMRI activations for the determination of hemisphere language dominance was evaluated in comparison with intracarotid amytal testing (IAT). Twenty-two patients were studied by IAT (bilateral in 13, unilateral in 9 patients) and fMRI using a paradigm requiring semantic decisions. Global and regional (frontal and temporoparietal) lateralisation indices (LI) were calculated from the number of activated (r>0.4) voxels in both hemispheres. Frontolateral activations associated with the language task were seen in all patients, temporoparietal activations in 20 of 22. Regional LI corresponded better with IAT results than global LI. Frontolateral LI were consistent with IAT in all patients with bilateral IAT (including three patients with right dominant and one patient with bilateral language representation) and were not conflicting in any of the patients with unilateral IAT. Temporoparietal LI were discordant with IAT in two patients with atypical language representation. In the determination of hemisphere dominance for language, regional analysis of fMRI activation is superior to global analysis. In cases with clear-cut fMRI lateralisation, i.e. consistent lateralised activation of frontal and temporoparietal language zones, IAT may be unnecessary. FMRI should be performed prior to IAT in all patients going to be operated in brain regions potentially involved in language. (orig.)

  13. Concomitant administration of fluoxetine and amantadine modulates the activity of peritoneal macrophages of rats subjected to a forced swimming test.

    Science.gov (United States)

    Roman, Adam; Rogóz, Zofia; Kubera, Marta; Nawrat, Dominika; Nalepa, Irena

    2009-01-01

    Recent studies show that administration of a non-competitive NMDA receptor antagonist, amantadine (AMA), potentiates the action of antidepressant drugs. Since antidepressants may modulate functioning of the immune system and activation of a pro-inflammatory response in depressive disorders is frequently reported, the aim of the present study was to examine whether a combined administration of AMA and the antidepressant, fluoxetine (FLU), to rats subsequently subjected to a forced swimming test (FST) modifies the parameters of macrophage activity, directly related to their immunomodulatory functions, i.e., arginase (ARG) activity and synthesis of nitric oxide (NO). We found that 10 mg/kg AMA and 10 mg/kg FLU, ineffective in FST for antidepressant-like activity when administered alone, increased the ARG/NO ratio in macrophages when administered concomitantly. This effect was accompanied by a decrease of cellular adherence. Concurrently, the basal metabolic activity of the cells measured with reduction of resazurin, and intracellular host defense as assessed by a synthesis of superoxide anion, were not affected by such antidepressive treatment. Our data indicate that co-administration of AMA and FLU decreases the pro-inflammatory properties of macrophages and causes a redirection of immune response toward anti-inflammatory activity, as one can anticipate in the case of an effective antidepressive treatment.

  14. Test program for closure activities at a mixed waste disposal site at the Savannah River Plant

    International Nuclear Information System (INIS)

    Cook, J.R.; Harley, J.P. Jr.

    1988-01-01

    A 58-acre site at the Savannah River Plant which was used for disposal of low-level radioactive waste and quantities of the hazardous materials lead, cadmium, scintillation fluid, and oil will be the first large waste site at the Savannah River Plant to be permanently closed. The actions leading to closure of the facility will include surface stabilization and capping of the site. Test programs have been conducted to evaluate the effectiveness of dynamic compaction as a stabilization technique and the feasibility of using locally derived clay as a capping material

  15. Preclinical Testing of Novel Oxytocin Receptor Activators in Models of Autism Phenotypes

    Science.gov (United States)

    2015-11-30

    higher incidence of autism observed in male versus female children . BALB/cByJ Cohort 1 (n ¼ 6 per treatment group; 6e7 weeks of age) was tested for acute...Veenstra-Vanderweele, J., 2011. A systematic review of medical treatments for children with autism spectrum disorders. Pediatrics 127, e1312ee1321. Melis...R.L., Leserman, J., Jarskog, L.F., Penn, D.L., 2011. Intranasal oxytocin reduces psychotic symptoms and improves theory of mind and social perception

  16. Estimate of uncertainties correlated and no correlated associated to performance tests of activity meters

    International Nuclear Information System (INIS)

    Sousa, C.H.S.; Teixeira, G.J.; Peixoto, J.G.P.

    2014-01-01

    Activimeters should undergo performance for verifying the functionality tests as technical recommendations. This study estimated the associated expanded uncertainties uncorrelated to the results conducted on three instruments, two detectors with ionization chamber and one with Geiger Mueller tubes. For this we used a standard reference source and screened certified by the National Institute of Technology and Standardization. The methodology of this research was based on the protocols listed in the technical document of the International Atomic Energy Agency. Later two quantities were correlated presenting real correlation and improving expanded uncertainty 3.7%. (author)

  17. GPR30 activation decreases anxiety in the open field test but not in the elevated plus maze test in female mice.

    Science.gov (United States)

    Anchan, Divya; Clark, Sara; Pollard, Kevin; Vasudevan, Nandini

    2014-01-01

    The GPR30 is a novel estrogen receptor (ER) that is a candidate membrane ER based on its binding to 17β estradiol and its rapid signaling properties such as activation of the extracellular-regulated kinase (ERK) pathway. Its distribution in the mouse limbic system predicts a role for this receptor in the estrogenic modulation of anxiety behaviors in the mouse. A previous study showed that chronic administration of a selective agonist to the GPR30 receptor, G-1, in the female rat can improve spatial memory, suggesting that GPR30 plays a role in hippocampal-dependent cognition. In this study, we investigated the effect of a similar chronic administration of G-1 on behaviors that denote anxiety in adult ovariectomized female mice, using the elevated plus maze (EPM) and the open field test as well as the activation of the ERK pathway in the hippocampus. Although estradiol benzoate had no effect on behaviors in the EPM or the open field, G-1 had an anxiolytic effect solely in the open field that was independent of ERK signaling in either the ventral or dorsal hippocampus. Such an anxiolytic effect may underlie the ability of G-1 to increase spatial memory, by acting on the hippocampus.

  18. The Spotlight activity: Development and feasibility test of a naturalistic attention-redirection well-being intervention

    Directory of Open Access Journals (Sweden)

    Lilian Shin

    2018-03-01

    Full Text Available Positive activities, such as savoring, gratitude, and optimism, have been shown to boost positive emotions and reduce negative emotions. We argue that a shared mechanism driving their well-being benefits is the redirection of attention. In this feasibility study, we develop and pilot-test this mechanism with a novel positive activity intervention, the “spotlight activity,” that taught participants how to become mindful of where their attention was and to redirect it as needed. Individuals (initial N = 108 were randomly assigned to a 5-week spotlight activity intervention or to a waitlist control group and were assessed on measures of psychological well-being, need satisfaction, and hassles and uplifts. Preliminary results showed that, at post-test, the spotlight group reported significantly higher life satisfaction, meaning in life, and general weekly affect, as well as significantly lower negative affect and hassle intensity. The study provided initial evidence for the feasibility of a novel attention-redirection intervention and its potential to increase psychological well-being.

  19. Further Examination of the Vibratory Loads Reduction Results from the NASA/ARMY/MIT Active Twist Rotor Test

    Science.gov (United States)

    Wilbur, Matthew L.; Yeager, William T., Jr.; Sekula, Martin K.

    2002-01-01

    The vibration reduction capabilities of a model rotor system utilizing controlled, strain-induced blade twisting are examined. The model rotor blades, which utilize piezoelectric active fiber composite actuators, were tested in the NASA Langley Transonic Dynamics Tunnel using open-loop control to determine the effect of active-twist on rotor vibratory loads. The results of this testing have been encouraging, and have demonstrated that active-twist rotor designs offer the potential for significant load reductions in future helicopter rotor systems. Active twist control was found to use less than 1% of the power necessary to operate the rotor system and had a pronounced effect on both rotating- and fixed-system loads, offering reductions in individual harmonic loads of up to 100%. A review of the vibration reduction results obtained is presented, which includes a limited set of comparisons with results generated using the second-generation version of the Comprehensive Analytical Model of Rotorcraft Aerodynamics and Dynamics (CAMRAD II) rotorcraft comprehensive analysis.

  20. IDENTIFICATION AND ANTIOXIDANT ACTIVITY TEST OF SOME COMPOUNDS FROM METHANOL EXTRACT PEEL OF BANANA (Musa paradisiaca Linn.

    Directory of Open Access Journals (Sweden)

    Sri Atun

    2010-06-01

    Full Text Available The objective of these research was measured activity as antioxidant some compounds in methanol extracts of peel of banana (Musa paradisiaca Linn., isolated some compounds which had activities as antioxidant, and determined this structure. Method of this study was extracted powdered peel of banana with methanol at room temperature. Extract was concentrated in vaccuo and then successively was partitioned with n-hexane, chloroform, etyl acetate, and buthanol. Antioxidant test from each fractions was measured by hydroxyl radical scavenger test with Fenton reaction method. The result of this study showed activity each fractions as  hydroxyl radical scavenger activity of chloroform, etyl acetate, and buthanol fraction were IC50 693.15; 2347.40; and 1071.14 mg/mL respectively. The isolation of secondary metabolite compounds from chloroform fraction obtained two isolate compounds. Identification by spectroscopy IR,  MS, 1H and 13C NMR one and two dimension showed that the compounds are 5,6,7,4'-tetrahidroxy-3,4-flavan-diol and a new compound cyclohexenon derivative (2-cyclohexene-1-on-2,4,4-trimethyl-3-O-2'-hydroxypropyl ether.   Keywords: antioxidant, peel of banana, Musa paradisiaca, hydroxyl radical scavenger

  1. Using Movement Test to Evaluate Effectiveness of Health and Fitness Activities of Students in Higher Education Institutions

    Directory of Open Access Journals (Sweden)

    S. Pashkevich

    2018-03-01

    Full Text Available The study objective is to evaluate the possibility of using screening methods for determining the effectiveness of health and fitness activities of students in higher education institutions. Materials and methods. The participants in the experiment were 37 first-year students (17 boys and 20 girls of the School of History of H. S. Skovoroda Kharkiv National Pedagogical University. The experiment lasted during the fall semester. Using the Framingham method for analyzing weekly timing, the study conducted a survey among the students on their level of motor activity and performed a functional movement screen testing. To tentatively evaluate the cause and effect relationship between the level of motor activity and the occurrence of a pathological movement pattern, the study used the Spearman’s rank correlation coefficient. The characteristics between the groups were analyzed by using the Mann-Whitney test for comparing the distribution of ordinal variables. Results. The correlation analysis showed that the first-year students’ motor activity was positively related to the results of functional movement screening (R=+0.69, p< 0.05. At the same time, the students (EG1 who mainly had a high level of physical activity at physical education classes showed low values of functional movement evaluation, compared to the students (EG2 participating in extra-curricular physical activity. In EG1, the overall screening score was 10.3±0.7, in EG2 — 14.2±0.9 (p<0.05. Conclusions. The students with insufficient weekly motor activity had risk values of the test (10.3±0.7, which requires further analysis of the causes of a pathological movement pattern. The study results have confirmed the existence of the relationship between motor activity indicators and functional movement evaluation (R=+0.69, p<0.05. This provides a way to use the screening method of determining motor competence for the effectiveness evaluation of health and fitness programs, but further

  2. Performance test results of noninvasive characterization of RCRA surrogate waste by prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Propp, W.A.

    1997-11-01

    A performance evaluation to determine the feasibility of using prompt gamma neutron activation analysis (PGNAA) for noninvasive, quantitative assay of mixed waste containers was sponsored by DOE's Office of Technology Development (OTD), the Mixed Waste Focus Area (MWFA), and the Idaho National Engineering and Environmental Laboratory (INEEL). The evaluation was conducted using a surrogate waste, based on Portland cement, that was spiked with three RCRA metals, mercury, cadmium, and lead. The results indicate that PGNAA has potential as a process monitor. However, further development is required to improve its sensitivity to meet regulatory requirements for determination of these RCRA metals

  3. Testing and Analysis of Activities of Daily Living Data with Machine Learning Algorithms

    OpenAIRE

    Ayse Cufoglu; Adem Coskun

    2016-01-01

    It is estimated that 28% of European Union’s population will be aged 65 or older by 2060. Europe is getting older and this has a high impact on the estimated cost to be spent for older people. This is because, compared to the younger generation, older people are more at risk to have/face cognitive impairment, frailty and social exclusion, which could have negative effects on their lives as well as the economy of the European Union. The ‘active and independent ageing’ concept aims to support o...

  4. Artificial Neural Networks for Reducing Computational Effort in Active Truncated Model Testing of Mooring Lines

    DEFF Research Database (Denmark)

    Christiansen, Niels Hørbye; Voie, Per Erlend Torbergsen; Høgsberg, Jan Becker

    2015-01-01

    simultaneously, this method is very demanding in terms of numerical efficiency and computational power. Therefore, this method has not yet proved to be feasible. It has recently been shown how a hybrid method combining classical numerical models and artificial neural networks (ANN) can provide a dramatic...... prior to the experiment and with a properly trained ANN it is no problem to obtain accurate simulations much faster than real time-without any need for large computational capacity. The present study demonstrates how this hybrid method can be applied to the active truncated experiments yielding a system...

  5. Modeling learning and memory using verbal learning tests: results from ACTIVE.

    Science.gov (United States)

    Gross, Alden L; Rebok, George W; Brandt, Jason; Tommet, Doug; Marsiske, Michael; Jones, Richard N

    2013-03-01

    To investigate the influence of memory training on initial recall and learning. The Advanced Cognitive Training for Independent and Vital Elderly study of community-dwelling adults older than age 65 (n = 1,401). We decomposed trial-level recall in the Auditory Verbal Learning Test (AVLT) and Hopkins Verbal Learning Test (HVLT) into initial recall and learning across trials using latent growth models. Trial-level increases in words recalled in the AVLT and HVLT at each follow-up visit followed an approximately logarithmic shape. Over the 5-year study period, memory training was associated with slower decline in Trial 1 AVLT recall (Cohen's d = 0.35, p = .03) and steep pre- and posttraining acceleration in learning (d = 1.56, p learning, d = 3.10, p memory-trained group had a higher level of recall than the control group through the end of the 5-year study period despite faster decline in learning. This study contributes to the understanding of the mechanisms by which training benefits memory and expands current knowledge by reporting long-term changes in initial recall and learning, as measured from growth models and by characterization of the impact of memory training on these components. Results reveal that memory training delays the worsening of memory span and boosts learning.

  6. Porcine E. coli: virulence-associated genes, resistance genes and adhesion and probiotic activity tested by a new screening method.

    Science.gov (United States)

    Schierack, Peter; Rödiger, Stefan; Kuhl, Christoph; Hiemann, Rico; Roggenbuck, Dirk; Li, Ganwu; Weinreich, Jörg; Berger, Enrico; Nolan, Lisa K; Nicholson, Bryon; Römer, Antje; Frömmel, Ulrike; Wieler, Lothar H; Schröder, Christian

    2013-01-01

    We established an automated screening method to characterize adhesion of Escherichia coli to intestinal porcine epithelial cells (IPEC-J2) and their probiotic activity against infection by enteropathogenic E. coli (EPEC). 104 intestinal E. coli isolates from domestic pigs were tested by PCR for the occurrence of virulence-associated genes, genes coding for resistances to antimicrobial agents and metals, and for phylogenetic origin by PCR. Adhesion rates and probiotic activity were examined for correlation with the presence of these genes. Finally, data were compared with those from 93 E. coli isolates from wild boars. Isolates from domestic pigs carried a broad variety of all tested genes and showed great diversity in gene patterns. Adhesions varied with a maximum of 18.3 or 24.2 mean bacteria adherence per epithelial cell after 2 or 6 hours respectively. Most isolates from domestic pigs and wild boars showed low adherence, with no correlation between adhesion/probiotic activity and E. coli genes or gene clusters. The gene sfa/foc, encoding for a subunit of F1C fimbriae did show a positive correlative association with adherence and probiotic activity; however E. coli isolates from wild boars with the sfa/foc gene showed less adhesion and probiotic activity than E. coli with the sfa/foc gene isolated from domestic pigs after 6 hour incubation. In conclusion, screening porcine E. coli for virulence associated genes genes, adhesion to intestinal epithelial cells, and probiotic activity revealed a single important adhesion factor, several probiotic candidates, and showed important differences between E. coli of domestic pigs and wild boars.

  7. Porcine E. coli: virulence-associated genes, resistance genes and adhesion and probiotic activity tested by a new screening method.

    Directory of Open Access Journals (Sweden)

    Peter Schierack

    Full Text Available We established an automated screening method to characterize adhesion of Escherichia coli to intestinal porcine epithelial cells (IPEC-J2 and their probiotic activity against infection by enteropathogenic E. coli (EPEC. 104 intestinal E. coli isolates from domestic pigs were tested by PCR for the occurrence of virulence-associated genes, genes coding for resistances to antimicrobial agents and metals, and for phylogenetic origin by PCR. Adhesion rates and probiotic activity were examined for correlation with the presence of these genes. Finally, data were compared with those from 93 E. coli isolates from wild boars. Isolates from domestic pigs carried a broad variety of all tested genes and showed great diversity in gene patterns. Adhesions varied with a maximum of 18.3 or 24.2 mean bacteria adherence per epithelial cell after 2 or 6 hours respectively. Most isolates from domestic pigs and wild boars showed low adherence, with no correlation between adhesion/probiotic activity and E. coli genes or gene clusters. The gene sfa/foc, encoding for a subunit of F1C fimbriae did show a positive correlative association with adherence and probiotic activity; however E. coli isolates from wild boars with the sfa/foc gene showed less adhesion and probiotic activity than E. coli with the sfa/foc gene isolated from domestic pigs after 6 hour incubation. In conclusion, screening porcine E. coli for virulence associated genes genes, adhesion to intestinal epithelial cells, and probiotic activity revealed a single important adhesion factor, several probiotic candidates, and showed important differences between E. coli of domestic pigs and wild boars.

  8. Serological testing versus other strategies for diagnosis of active tuberculosis in India: a cost-effectiveness analysis.

    Directory of Open Access Journals (Sweden)

    David W Dowdy

    2011-08-01

    Full Text Available Undiagnosed and misdiagnosed tuberculosis (TB drives the epidemic in India. Serological (antibody detection TB tests are not recommended by any agency, but widely used in many countries, including the Indian private sector. The cost and impact of using serology compared with other diagnostic techniques is unknown.Taking a patient cohort conservatively equal to the annual number of serological tests done in India (1.5 million adults suspected of having active TB, we used decision analysis to estimate costs and effectiveness of sputum smear microscopy (US$3.62 for two smears, microscopy plus automated liquid culture (mycobacterium growth indicator tube [MGIT], US$20/test, and serological testing (anda-tb ELISA, US$20/test. Data on test accuracy and costs were obtained from published literature. We adopted the perspective of the Indian TB control sector and an analysis frame of 1 year. Our primary outcome was the incremental cost per disability-adjusted life year (DALY averted. We performed one-way sensitivity analysis on all model parameters, with multiway sensitivity analysis on variables to which the model was most sensitive. If used instead of sputum microscopy, serology generated an estimated 14,000 more TB diagnoses, but also 121,000 more false-positive diagnoses, 102,000 fewer DALYs averted, and 32,000 more secondary TB cases than microscopy, at approximately four times the incremental cost (US$47.5 million versus US$11.9 million. When added to high-quality sputum smears, MGIT culture was estimated to avert 130,000 incremental DALYs at an incremental cost of US$213 per DALY averted. Serology was dominated by (i.e., more costly and less effective than MGIT culture and remained less economically favorable than sputum smear or TB culture in one-way and multiway sensitivity analyses.In India, sputum smear microscopy remains the most cost-effective diagnostic test available for active TB; efforts to increase access to quality-assured microscopy

  9. Test-beam activities and results for the ATLAS ITk pixel detector

    Science.gov (United States)

    Bisanz, T.

    2017-12-01

    The Phase-II upgrade of the LHC aims at an increase of the instantaneous luminosity up to about 5×1034 cm-2 s-1. To cope with the resulting challenges the current Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) system. The Pixel Detector will have to deal with occupancies of about 300 hits/FE/s as well as a fluence of around 2×1016 neq cm-2. Various sensor layouts are under development, aiming at providing a high performance, cost effective pixel instrumentation to cover an active area of about 10 m2. These range from thin planar silicon, 3D silicon, to active CMOS sensors. After extensive characterization of the sensors in the lab, their charge collection properties and hit efficiency are measured in common testbeam campaigns, which provide valuable feedback for improvements of the layout. Testbeam measurements of the final prototypes will be used for the decision of which sensor types will be installed in ITk. The setups used in the ITk Pixel testbeam campaigns will be presented, including the common track reconstruction and analysis software. Results from the latest measurements will be shown, highlighting some of the developments and challenges for the ITk Pixel sensors.

  10. Recent Advances in Active Infrared Thermography for Non-Destructive Testing of Aerospace Components.

    Science.gov (United States)

    Ciampa, Francesco; Mahmoodi, Pooya; Pinto, Fulvio; Meo, Michele

    2018-02-16

    Active infrared thermography is a fast and accurate non-destructive evaluation technique that is of particular relevance to the aerospace industry for the inspection of aircraft and helicopters' primary and secondary structures, aero-engine parts, spacecraft components and its subsystems. This review provides an exhaustive summary of most recent active thermographic methods used for aerospace applications according to their physical principle and thermal excitation sources. Besides traditional optically stimulated thermography, which uses external optical radiation such as flashes, heaters and laser systems, novel hybrid thermographic techniques are also investigated. These include ultrasonic stimulated thermography, which uses ultrasonic waves and the local damage resonance effect to enhance the reliability and sensitivity to micro-cracks, eddy current stimulated thermography, which uses cost-effective eddy current excitation to generate induction heating, and microwave thermography, which uses electromagnetic radiation at the microwave frequency bands to provide rapid detection of cracks and delamination. All these techniques are here analysed and numerous examples are provided for different damage scenarios and aerospace components in order to identify the strength and limitations of each thermographic technique. Moreover, alternative strategies to current external thermal excitation sources, here named as material-based thermography methods, are examined in this paper. These novel thermographic techniques rely on thermoresistive internal heating and offer a fast, low power, accurate and reliable assessment of damage in aerospace composites.

  11. Recent Advances in Active Infrared Thermography for Non-Destructive Testing of Aerospace Components

    Directory of Open Access Journals (Sweden)

    Francesco Ciampa

    2018-02-01

    Full Text Available Active infrared thermography is a fast and accurate non-destructive evaluation technique that is of particular relevance to the aerospace industry for the inspection of aircraft and helicopters’ primary and secondary structures, aero-engine parts, spacecraft components and its subsystems. This review provides an exhaustive summary of most recent active thermographic methods used for aerospace applications according to their physical principle and thermal excitation sources. Besides traditional optically stimulated thermography, which uses external optical radiation such as flashes, heaters and laser systems, novel hybrid thermographic techniques are also investigated. These include ultrasonic stimulated thermography, which uses ultrasonic waves and the local damage resonance effect to enhance the reliability and sensitivity to micro-cracks, eddy current stimulated thermography, which uses cost-effective eddy current excitation to generate induction heating, and microwave thermography, which uses electromagnetic radiation at the microwave frequency bands to provide rapid detection of cracks and delamination. All these techniques are here analysed and numerous examples are provided for different damage scenarios and aerospace components in order to identify the strength and limitations of each thermographic technique. Moreover, alternative strategies to current external thermal excitation sources, here named as material-based thermography methods, are examined in this paper. These novel thermographic techniques rely on thermoresistive internal heating and offer a fast, low power, accurate and reliable assessment of damage in aerospace composites.

  12. Test-beam activities and results for the ATLAS ITk pixel detector

    CERN Document Server

    Bisanz, Tobias; The ATLAS collaboration

    2017-01-01

    The Phase-II upgrade of the LHC will result in an increase of the instantaneous luminosity up to about 5×1034 cm−2s−1. To cope with the challenges the current Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) system. The Pixel Detector will have to deal with occupancies of about 300~hits/FE/s as well as a fluence of 2×1016neqcm−2. Various sensor layouts are under development, aiming at providing a high performance, cost effective pixel instrumentation to cover an active area of about 10~m2. These range from thin planar silicon, over 3D silicon, to active CMOS sensors. After extensive characterization of the sensors in the lab, their charge collection properties and hit efficiency are measured in common testbeam campaigns, which provide valuable feedback for improvements of the layout. Testbeam measurements of the final prototypes will be used for the decision of which sensor types will be installed in ITk. The setups used in the ITk Pixel testbeam campaigns will be presented, inclu...

  13. Test-beam activities and results for the ATLAS ITk pixel detector

    CERN Document Server

    Bisanz, Tobias; The ATLAS collaboration

    2017-01-01

    The Phase-II upgrade of the LHC will result in an increase of the instantaneous luminosity up to about $5\\times10^{34}~\\text{cm}^{-2}\\text{s}^{-1}$. To cope with the resulting challenges the current Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) system. The Pixel Detector will have to deal with occupancies of about 300~hits/FE/s as well as a fluence of $2\\times10^{16}~\\text{n}_\\text{eq}\\text{cm}^{-2}$. Various sensor layouts are under development, aiming at providing a high performance, cost effective pixel instrumentation to cover an active area of about $10~\\text{m}^2$. These range from thin planar silicon, over 3D silicon, to active CMOS sensors.\\par After extensive characterization of the sensors in the lab, their charge collection properties and hit efficiency are measured in common testbeam campaigns, which provide valuable feedback for improvements of the layout. Testbeam measurements of the final prototypes will be used for the decision of which sensor types will be installed in...

  14. New technological development of passive and active vibration control: analysis and test

    Science.gov (United States)

    Matsuzaki, Yuji; Ikeda, Tadashige; Boller, Christian

    2005-04-01

    We present a brief summary of new technical developments of passive and active vibration controls which we have performed for the last several years partly as an international collaborative R&D project on Smart Materials and Structural Systems sponsored by the Japanese Ministry of Economy, Trade and Industry. In connection with the passive damping control, shape memory alloys (SMAs) were used as damping elements. To examine the effect of damping enhancement, beams with SMA films bonded onto them or SMA wires embedded into them were made, and free damped oscillations were measured. The damping coefficient increased by more than 100% compared with the beams without SMAs. Thermodynamic behaviors of an SMA wire and film were also investigated experimentally and numerically. In active vibration control, a new concept of smart material systems was proposed. That is a partially magnetized alloy, which is stiff and strong enough as a structural element and responds sufficiently quickly as an actuator due to an electromagnetic force. A simplified experiment and numerical simulation were performed and the results showed the feasibility of the proposed smart material system using the electromagnetic force.

  15. Test beam results of a depleted monolithic active pixel sensor (DMAPS) prototype

    Energy Technology Data Exchange (ETDEWEB)

    Obermann, Theresa; Hemperek, Tomasz; Huegging, Fabian; Krueger, Hans; Wermes, Norbert [Bonn Univ. (Germany); Schwenker, Benjamin [Goettingen Univ. (Germany); Collaboration: ATLAS Pixel-Collaboration

    2016-07-01

    New monolithic detector concepts are currently being explored for future particle physics experiments, in particular for the upgrade of the ATLAS detector. Common to monolithic pixel detectors is the integration of the front-end circuitry and the sensor on the same silicon substrate. The DMAPS concept makes use of high resistive silicon as substrate. It enables the application of a high bias voltage to create a drift field for the charge collection in the sensor part as well as the full usage of CMOS logic in the same piece of silicon. DMAPS prototypes from several foundries are available since three years and have been extensively characterized in the lab. In this talk, results of test beam campaigns, with neutron irradiated prototypes implemented in the ESPROS process, are presented.

  16. Modeling and Field Test Planning Activities in Support of Disposal of Heat-Generating Waste in Salt

    Energy Technology Data Exchange (ETDEWEB)

    Rutqvist, Jonny; Blanco Martin, Laura; Mukhopadhyay, Sumit; Houseworth, Jim; Birkholzer, Jens

    2014-09-26

    The modeling efforts in support of the field test planning conducted at LBNL leverage on recent developments of tools for modeling coupled thermal-hydrological-mechanical-chemical (THMC) processes in salt and their effect on brine migration at high temperatures. This work includes development related to, and implementation of, essential capabilities, as well as testing the model against relevant information and published experimental data related to the fate and transport of water. These are modeling capabilities that will be suitable for assisting in the design of field experiment, especially related to multiphase flow processes coupled with mechanical deformations, at high temperature. In this report, we first examine previous generic repository modeling results, focusing on the first 20 years to investigate the expected evolution of the different processes that could be monitored in a full-scale heater experiment, and then present new results from ongoing modeling of the Thermal Simulation for Drift Emplacement (TSDE) experiment, a heater experiment on the in-drift emplacement concept at the Asse Mine, Germany, and provide an update on the ongoing model developments for modeling brine migration. LBNL also supported field test planning activities via contributions to and technical review of framework documents and test plans, as well as participation in workshops associated with field test planning.

  17. Design of multi-megawatt actively cooled beam dumps for the Neutral-Beam Engineering Test Facility

    International Nuclear Information System (INIS)

    Paterson, J.A.; Koehler, G.; Wells, R.P.

    1981-10-01

    The Neutral Beam Engineering Test Facility will test Neutral Beam Sources up to 170 keV, 65 Amps, with 30 second beam-on times. For this application actively cooled beam dumps for both the neutral and ionized particles will be required. The dumps will be able to dissipate a wide range of power density profiles by utilizing a standard modular panel design which is incorporated into a moveable support structure. The thermal hydraulic design of the panels permit the dissipation of 2 kW/cm 2 anywhere on the panel surface. The water requirements of the dumps are optimized by restricting the flow to panel sections where the heat flux falls short of the design value. The mechanical design of the beam-dump structures is described along with tests performed on a prototype panel. The prototype tests were performed on two different panel designs, one manufactured by Mc Donnell Douglas (MDAC) the other by United Technologies (UT). The dissipation capabilities of the panels were tested at the critical regions to verify their use in the beam dump assemblies

  18. Wind tunnel test on airfoil Riso-B1-18 with an Active Trailing Edge Flap

    DEFF Research Database (Denmark)

    Bak, Christian; Gaunaa, Mac; Andersen, Peter Bjørn

    2010-01-01

    A wind tunnel test of the wind turbine airfoil Risø-B1-18 equipped with an Active Trailing Edge Flap (ATEF) was carried out. The ATEF was 9% of the total chord, made of piezo electric actuators attached to the trailing edge of a non-deformable airfoil and actuated using an (electric) amplifier....... The airfoil was tested at Re = 1.66 × 106. Steady state and dynamic tests were carried out with prescribed deflections of the ATEF. The steady state tests showed that deflecting the ATEF towards the pressure side (positive ) translated the lift curve to higher lift values and deflecting the ATEF towards...... the suction side (negative ) translated the lift curve to lower lift values. Testing the airfoil for a step change of the ATEF from = -3.0 to +1.8 showed that the obtainable cl was 0.10 to 0.13 in the linear part of the lift curve. Modeling the step response with an indicial function formulation showed...

  19. From starburst to quiescence: testing active galactic nucleus feedback in rapidly quenching post-starburst galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Yesuf, Hassen M.; Faber, S. M.; Trump, Jonathan R.; Koo, David C.; Fang, Jerome J.; Liu, F. S. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Wild, Vivienne [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, KY16 9SS (United Kingdom); Hayward, Christopher C. [Heidelberger Institut für Theoretische Studien, Schloss-Wolfsbrunnenweg 35, D-69118 Heidelberg (Germany)

    2014-09-10

    Post-starbursts are galaxies in transition from the blue cloud to the red sequence. Although they are rare today, integrated over time they may be an important pathway to the red sequence. This work uses Sloan Digital Sky Survey, the Galaxy Evolution Explorer, and Wide-field Infrared Survey Explorer observations to identify the evolutionary sequence from starbursts to fully quenched post-starbursts (QPSBs) in the narrow mass range log M(M {sub ☉}) = 10.3-10.7, and identifies 'transiting' post-starbursts (TPSBs) which are intermediate between these two populations. In this mass range, ∼0.3% of galaxies are starbursts, ∼0.1% are QPSBs, and ∼0.5% are the transiting types in between. The TPSBs have stellar properties that are predicted for fast-quenching starbursts and morphological characteristics that are already typical of early-type galaxies. The active galactic nucleus (AGN) fraction, as estimated from optical line ratios, of these post-starbursts is about three times higher (≳ 36% ± 8%) than that of normal star forming galaxies of the same mass, but there is a significant delay between the starburst phase and the peak of nuclear optical AGN activity (median age difference of ≳ 200 ± 100 Myr), in agreement with previous studies. The time delay is inferred by comparing the broadband near-NUV-to-optical photometry with stellar population synthesis models. We also find that starbursts and post-starbursts are significantly more dust obscured than normal star forming galaxies in the same mass range. About 20% of the starbursts and 15% of the TPSBs can be classified as 'dust-obscured galaxies' (DOGs), with a near-UV-to-mid-IR flux ratio of ≳ 900, while only 0.8% of normal galaxies are DOGs. The time delay between the starburst phase and AGN activity suggests that AGNs do not play a primary role in the original quenching of starbursts but may be responsible for quenching later low-level star formation by removing gas and dust during

  20. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn’s Disease

    Science.gov (United States)

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-01-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn’s disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-value<0.05 was considered as statistically significant. RESULTS Of the 30 patients with active CD, 11(36.7%) were men and 19 (63.3%) were women with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease. PMID:27252815

  1. Measurement Testing of Radon Gas for Fault Activity Detection in Rahtawu Muria, Pati

    International Nuclear Information System (INIS)

    Suntoko, Hadi; Hamzah, Imam

    2004-01-01

    The radon surface can be used to investigates not only for environment but also to be develop in an earth application. The investigation is carried out at the Rahtawu fault, that includes, to the Pati regency which is located 40 km South of ULA. The objective of study to measure the radon released from the fracture zone activities. RDA equipment is being used to measure the radon gas released. The result shown that the high value of radon is 311 cpm with the background of 18 cpm, whereas the low value falls at 0 cpm. The tattoo value are influenced by the soil condition, tattoo time, hardness, weather, soil/stone porosity and fault possession. (author)

  2. Testing the Accuracy of Data-driven MHD Simulations of Active Region Evolution

    Energy Technology Data Exchange (ETDEWEB)

    Leake, James E.; Linton, Mark G. [U.S. Naval Research Laboratory, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States); Schuck, Peter W., E-mail: james.e.leake@nasa.gov [NASA Goddard Space Flight Center, 8800 Greenbelt Road, Greenbelt, MD 20771 (United States)

    2017-04-01

    Models for the evolution of the solar coronal magnetic field are vital for understanding solar activity, yet the best measurements of the magnetic field lie at the photosphere, necessitating the development of coronal models which are “data-driven” at the photosphere. We present an investigation to determine the feasibility and accuracy of such methods. Our validation framework uses a simulation of active region (AR) formation, modeling the emergence of magnetic flux from the convection zone to the corona, as a ground-truth data set, to supply both the photospheric information and to perform the validation of the data-driven method. We focus our investigation on how the accuracy of the data-driven model depends on the temporal frequency of the driving data. The Helioseismic and Magnetic Imager on NASA’s Solar Dynamics Observatory produces full-disk vector magnetic field measurements at a 12-minute cadence. Using our framework we show that ARs that emerge over 25 hr can be modeled by the data-driving method with only ∼1% error in the free magnetic energy, assuming the photospheric information is specified every 12 minutes. However, for rapidly evolving features, under-sampling of the dynamics at this cadence leads to a strobe effect, generating large electric currents and incorrect coronal morphology and energies. We derive a sampling condition for the driving cadence based on the evolution of these small-scale features, and show that higher-cadence driving can lead to acceptable errors. Future work will investigate the source of errors associated with deriving plasma variables from the photospheric magnetograms as well as other sources of errors, such as reduced resolution, instrument bias, and noise.

  3. Testing the effectiveness of automated acoustic sensors for monitoring vocal activity of Marbled Murrelets Brachyramphus marmoratus

    Science.gov (United States)

    Cragg, Jenna L.; Burger, Alan E.; Piatt, John F.

    2015-01-01

    Cryptic nest sites and secretive breeding behavior make population estimates and monitoring of Marbled Murrelets Brachyramphus marmoratus difficult and expensive. Standard audio-visual and radar protocols have been refined but require intensive field time by trained personnel. We examined the detection range of automated sound recorders (Song Meters; Wildlife Acoustics Inc.) and the reliability of automated recognition models (“recognizers”) for identifying and quantifying Marbled Murrelet vocalizations during the 2011 and 2012 breeding seasons at Kodiak Island, Alaska. The detection range of murrelet calls by Song Meters was estimated to be 60 m. Recognizers detected 20 632 murrelet calls (keer and keheer) from a sample of 268 h of recordings, yielding 5 870 call series, which compared favorably with human scanning of spectrograms (on average detecting 95% of the number of call series identified by a human observer, but not necessarily the same call series). The false-negative rate (percentage of murrelet call series that the recognizers failed to detect) was 32%, mainly involving weak calls and short call series. False-positives (other sounds included by recognizers as murrelet calls) were primarily due to complex songs of other bird species, wind and rain. False-positives were lower in forest nesting habitat (48%) and highest in shrubby vegetation where calls of other birds were common (97%–99%). Acoustic recorders tracked spatial and seasonal trends in vocal activity, with higher call detections in high-quality forested habitat and during late July/early August. Automated acoustic monitoring of Marbled Murrelet calls could provide cost-effective, valuable information for assessing habitat use and temporal and spatial trends in nesting activity; reliability is dependent on careful placement of sensors to minimize false-positives and on prudent application of digital recognizers with visual checking of spectrograms.

  4. Assessing research activity and capacity of community-based organizations: development and pilot testing of an instrument.

    Science.gov (United States)

    Humphries, Debbie L; Carroll-Scott, Amy; Mitchell, Leif; Tian, Terry; Choudhury, Shonali; Fiellin, David A

    2014-01-01

    Although awareness of the importance of the research capacity of community-based organizations (CBOs) is growing, a uniform framework of the research capacity domains within CBOs has not yet been developed. To develop a framework and instrument (the Community REsearch Activity assessment Tool [CREAT]) for assessing the research activity and capacity of CBOs that incorporates awareness of the different data collection and analysis priorities of CBOs. We conducted a review of existing tools for assessing research capacity to identify key capacity domains. Instrument items were developed through an iterative process with CBO representatives and community researchers. The CREAT was then pilot tested with 30 CBOs. The four primary domains of the CREAT framework include 1) organizational support for research, 2) generalizable experiences, 3) research specific experiences, and 4) funding. Organizations reported a high prevalence of activities in the research-specific experiences domain, including conducting literature reviews (70%), use of research terminology (83%), and primary data collection (100%). Respondents see research findings as important to improve program and service delivery, and to seek funds for new programs and services. Funders, board members, and policymakers are the most important dissemination audiences. The work reported herein advances the field of CBO research capacity by developing a systematic framework for assessing research activity and capacity relevant to the work of CBOs, and by developing and piloting an instrument to assess activity in these domains.

  5. Development, content validity and test-retest reliability of the Lifelong Physical Activity Skills Battery in adolescents.

    Science.gov (United States)

    Hulteen, Ryan M; Barnett, Lisa M; Morgan, Philip J; Robinson, Leah E; Barton, Christian J; Wrotniak, Brian H; Lubans, David R

    2018-03-28

    Numerous skill batteries assess fundamental motor skill (e.g., kick, hop) competence. Few skill batteries examine lifelong physical activity skill competence (e.g., resistance training). This study aimed to develop and assess the content validity, test-retest and inter-rater reliability of the "Lifelong Physical Activity Skills Battery". Development of the skill battery occurred in three stages: i) systematic reviews of lifelong physical activity participation rates and existing motor skill assessment tools, ii) practitioner consultation and iii) research expert consultation. The final battery included eight skills: grapevine, golf swing, jog, push-up, squat, tennis forehand, upward dog and warrior I. Adolescents (28 boys, 29 girls; M = 15.8 years, SD = 0.4 years) completed the Lifelong Physical Activity Skills Battery on two occasions two weeks apart. The skill battery was highly reliable (ICC = 0.84, 95% CI = 0.72-0.90) with individual skill reliability scores ranging from moderate (warrior I; ICC = 0.56) to high (tennis forehand; ICC = 0.82). Typical error (4.0; 95% CI 3.4-5.0) and proportional bias (r = -0.21, p = .323) were low. This study has provided preliminary evidence for the content validity and reliability of the Lifelong Physical Activity Skills Battery in an adolescent population.

  6. Driver ASIC Environmental Testing and Performance Optimization for SpaceBased Active Mirrors

    Science.gov (United States)

    Mejia Prada, Camilo

    Direct imaging of Earth-like planets requires techniques for light suppression, such as coronagraphs or nulling interferometers, in which deformable mirrors (DM) are a principal component. On ground-based systems, DMs are used to correct for turbulence in the Earth’s atmosphere in addition to static aberrations in the optics. For space-based observations, DMs are used to correct for static and quasi- static aberrations in the optical train. State-of-the-art, high-actuator count deformable mirrors suffer from external heavy and bulky electronics in which electrical connections are made through thousands of wires. We are instead developing Application Specific Integrated Circuits (ASICs) capable of direct integration with the DM in a single small package. This integrated ASIC-DM is ideal for space missions, where it offers significant reduction in mass, power and complexity, and performance compatible with high-contrast observations of exoplanets. We have successfully prototyped and tested a 32x32 format Switch-Mode (SM) ASIC which consumes only 2mW static power (total, not per-actuator). A number of constraints were imposed on key parameters of this ASIC design, including sub-picoamp levels of leakage across turned-off switches and from switch-to-substrate, control resolution of 0.04 mV, satisfactory rise/fall times, and a near-zero on-chip crosstalk over a useful range of operating temperatures. This driver ASIC technology is currently at TRL 4. This Supporting Technology proposal will further develop the ASIC technology to TRL 5 by carrying on environmental tests and further optimizing performance, with the end goal of making ASICs suitable for space-based deployment. The effort will be led by JPL, which has considerable expertise with DMs used in highcontrast imaging systems for exoplanet missions and in adaptive optic systems, and in design of DM driver electronics. Microscale, which developed the prototype of the ASICDM, will continue its development. We

  7. A temperature sensor implant for active implantable medical devices for in vivo subacute heating tests under MRI.

    Science.gov (United States)

    Silemek, Berk; Acikel, Volkan; Oto, Cagdas; Alipour, Akbar; Aykut, Zaliha Gamze; Algin, Oktay; Atalar, Ergin

    2018-05-01

    To introduce a temperature sensor implant (TSI) that mimics an active implantable medical device (AIMD) for animal testing of MRI heating. Computer simulations and phantom experiments poorly represent potential temperature increases. Animal experiments could be a better model, but heating experiments conducted immediately after the surgery suffer from alterations of the thermoregulatory and tissue properties during acute testing conditions. Therefore, the aim of this study was to introduce a temperature sensor implant that mimics an AIMD and capable of measuring the electrode temperature after implantation of the device without any further intervention at any time after the surgery in an animal model. A battery-operated TSI, which resembled an AIMD, was used to measure the lead temperature and impedance and the case temperature. The measured values were transmitted to an external computer via a low-power Bluetooth communication protocol. In addition to validation experiments on the phantom, a sheep experiment was conducted to test the feasibility of the system in subacute conditions. The measurements had a maximum of 0.5°C difference compared to fiber-optic temperature probes. In vivo animal experiments demonstrated feasibility of the system. An active implant, which can measure its own temperature, was proposed to investigate implant heating during MRI examinations. Magn Reson Med 79:2824-2832, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  8. [The echographic assessment of the activity of the inflammatory process in patients with chronic acalculous cholecystitis in the choleretic test].

    Science.gov (United States)

    Ivanov, L A; Barashkov, M N

    1995-01-01

    Ultrasonic investigations of the gallbladder in choleretic test were carried out in 186 patients with chronic acalculous cholecystitis (CAC): 47 with intensive, 76 with moderate and 31 with minimal exacerbation, 32 patients in remission and 36 control subjects. As shown by choleretic test, a reduction of latent period and gallbladder contraction duration, a decrease in discharged bile amount, bile discharge velocity, initial and final gallbladder volumes' ration and increased final gallbladder volume occurred in CAC patients. These changes were parallel to inflammation intensity. Three types of gallbladder contraction were revealed in choleretic test: a 3-phase contraction curve with the initial fast evacuation period, relaxation wave (enlarged gallbladder) and slow evacuation period (type 1); a 2-phase curve with fast and slow evacuation (type 2); a monophasic curve with slow evacuation (type 3). In the patients studied type 1 prevailed, while type 3 was not observed in the controls. With increasing inflammation activity in CAC patients a type-1 contraction frequency declined and disappeared in active exacerbation, whereas type 2 and especially type 3 contractions became more frequent.

  9. Potato dextrose agar antifungal susceptibility testing for yeasts and molds: evaluation of phosphate effect on antifungal activity of CMT-3.

    Science.gov (United States)

    Liu, Yu; Tortora, George; Ryan, Maria E; Lee, Hsi-Ming; Golub, Lorne M

    2002-05-01

    The broth macrodilution method (BMM) for antifungal susceptibility testing, approved by the National Committee for Clinical Laboratory Standards (NCCLS), was found to have deficiencies in testing of the antifungal activity of a new type of antifungal agent, a nonantibacterial chemically modified tetracycline (CMT-3). The high content of phosphate in the medium was found to greatly increase the MICs of CMT-3. To avoid the interference of phosphate in the test, a new method using potato dextrose agar (PDA) as a culture medium was developed. Eight strains of fungi, including five American Type Culture Collection strains and three clinical isolates, were used to determine the MICs of amphotericin B and itraconazole with both the BMM and the PDA methods. The MICs of the two antifungal agents determined with the PDA method showed 99% agreement with those determined with the BMM method within 1 log(2) dilution. Similarly, the overall reproducibility of the MICs with the PDA method was above 97%. Three other antifungal agents, fluconazole, ketoconazole, and CMT-3, were also tested in parallel against yeasts and molds with both the BMM and the PDA methods. The MICs of fluconazole and ketoconazole determined with the PDA method showed 100% agreement within 1 log(2) dilution of those obtained with the BMM method. However, the MICs of CMT-3 determined with the BMM method were as high as 128 times those determined with the PDA method. The effect of phosphate on the antifungal activity of CMT-3 was evaluated by adding Na2HPO4 to PDA in the new method. It was found that the MIC of CMT-3 against a Penicillium sp. increased from 0.5 microg/ml (control) to 2.0 microg/ml when the added phosphate was used at a concentration of 0.8 mg/ml, indicating a strong interference of Na2HPO4 with the antifungal activity of CMT-3. Except for fluconazole, all the other antifungal agents demonstrated clear end points among the yeasts and molds tested. Nevertheless, with its high reproducibility

  10. Operation Test of the Supercritical CO{sub 2} Compressor Supported with Active Magnetic Bearing

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Jae Eun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Seong Kuk; Lee, Jeong IK [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    In this paper, the operation test status of the SCIEL sCO{sub 2} AMB Compressor is briefly described. The Supercritical CO{sub 2} Brayton Cycle Integral Experiment Loop (SCIEL) has been installed in Korea Atomic Energy Research Institute (KAERI) to develop the element technologies for the sCO{sub 2} cycle power generation system. The operation of the SCIEL has mainly focused on sCO{sub 2} compressor development and establishing sCO{sub 2} system control logic. The installation of the SCIEL low compression loop was finished in December 2014 and research team succeeded in generating electric power on the supercritical state of the CO{sub 2} in May 2015. The SCIEL has been built in KAERI to develop the element technologies and the system control logics for the sCO{sub 2} cycle power conversion unit of the next generation reactor. For the stable operation of the sCO{sub 2} compressor under high rotational speed, the AMB sCO{sub 2} compressor was developed and achieved the maximum 40,000 rpm.

  11. Retention of activation and fission radionuclides by mallards from the Test Reactor Area radioactive leaching pond

    International Nuclear Information System (INIS)

    Halford, D.K.; Millard, J.B.; Schreckhise, R.G.

    1978-01-01

    Twenty semi-wild mallard ducks were banded, fitted with dorsal and ventral thermoluminescent dosimeter packets, and released on the Test Reactor Area radioactive leaching ponds. Ducks were live captured after 75 days and 145 days on the pond, placed in metabolic cages and whole-body counted periodically for 52 days. Ducks from each group were sacrificed immediately after capture, dissected, and muscle, feather, gut, and liver samples submitted for analyses. The remaining ducks were also sacrificed and dissected after the 52 day counting period. Concentrations of the 17 gamma emitting radionuclides detected at capture and after 52 days of physical and biological decay were compared. Highest mean radionuclide concentrations were found in feathers followed by gut, liver, and muscle. Effective and biological halflives of Zn-65, Cr-51, Cs-134, Cs-137, and Se-75 were determined and compared with data from previous studies. Samples are currently being analyzed for Pu-238, Pu-239-240, Am-241, Cm-242, Cm-244 and Sr-90. Further data analyses will be completed after data collection has terminated

  12. First tests of a novel radiation hard CMOS sensor process for Depleted Monolithic Active Pixel Sensors

    Science.gov (United States)

    Pernegger, H.; Bates, R.; Buttar, C.; Dalla, M.; van Hoorne, J. W.; Kugathasan, T.; Maneuski, D.; Musa, L.; Riedler, P.; Riegel, C.; Sbarra, C.; Schaefer, D.; Schioppa, E. J.; Snoeys, W.

    2017-06-01

    The upgrade of the ATLAS [1] tracking detector for the High-Luminosity Large Hadron Collider (LHC) at CERN requires novel radiation hard silicon sensor technologies. Significant effort has been put into the development of monolithic CMOS sensors but it has been a challenge to combine a low capacitance of the sensing node with full depletion of the sensitive layer. Low capacitance brings low analog power. Depletion of the sensitive layer causes the signal charge to be collected by drift sufficiently fast to separate hits from consecutive bunch crossings (25 ns at the LHC) and to avoid losing the charge by trapping. This paper focuses on the characterization of charge collection properties and detection efficiency of prototype sensors originally designed in the framework of the ALICE Inner Tracking System (ITS) upgrade [2]. The prototypes are fabricated both in the standard TowerJazz 180nm CMOS imager process [3] and in an innovative modification of this process developed in collaboration with the foundry, aimed to fully deplete the sensitive epitaxial layer and enhance the tolerance to non-ionizing energy loss. Sensors fabricated in standard and modified process variants were characterized using radioactive sources, focused X-ray beam and test beams before and after irradiation. Contrary to sensors manufactured in the standard process, sensors from the modified process remain fully functional even after a dose of 1015neq/cm2, which is the the expected NIEL radiation fluence for the outer pixel layers in the future ATLAS Inner Tracker (ITk) [4].

  13. Optimal Control Allocation with Load Sensor Feedback for Active Load Suppression, Flight-Test Performance

    Science.gov (United States)

    Miller, Christopher J.; Goodrick, Dan

    2017-01-01

    The problem of control command and maneuver induced structural loads is an important aspect of any control system design. The aircraft structure and the control architecture must be designed to achieve desired piloted control responses while limiting the imparted structural loads. The classical approach is to utilize high structural margins, restrict control surface commands to a limited set of analyzed combinations, and train pilots to follow procedural maneuvering limitations. With recent advances in structural sensing and the continued desire to improve safety and vehicle fuel efficiency, it is both possible and desirable to develop control architectures that enable lighter vehicle weights while maintaining and improving protection against structural damage. An optimal control technique has been explored and shown to achieve desirable vehicle control performance while limiting sensed structural loads to specified values. This technique has been implemented and flown on the National Aeronautics and Space Administration Full-scale Advanced Systems Testbed aircraft. The flight tests illustrate that the approach achieves the desired performance and show promising potential benefits. The flights also uncovered some important issues that will need to be addressed for production application.

  14. Feedback-related brain activity predicts learning from feedback in multiple-choice testing.

    Science.gov (United States)

    Ernst, Benjamin; Steinhauser, Marco

    2012-06-01

    Different event-related potentials (ERPs) have been shown to correlate with learning from feedback in decision-making tasks and with learning in explicit memory tasks. In the present study, we investigated which ERPs predict learning from corrective feedback in a multiple-choice test, which combines elements from both paradigms. Participants worked through sets of multiple-choice items of a Swahili-German vocabulary task. Whereas the initial presentation of an item required the participants to guess the answer, corrective feedback could be used to learn the correct response. Initial analyses revealed that corrective feedback elicited components related to reinforcement learning (FRN), as well as to explicit memory processing (P300) and attention (early frontal positivity). However, only the P300 and early frontal positivity were positively correlated with successful learning from corrective feedback, whereas the FRN was even larger when learning failed. These results suggest that learning from corrective feedback crucially relies on explicit memory processing and attentional orienting to corrective feedback, rather than on reinforcement learning.

  15. Recovery efficiency test project, Phase 2 activity report. Volume 2, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Overbey, W.K. Jr.; Salamy, S.P.; Locke, C.D.

    1989-02-01

    The Recovery Efficiency Test well project addressed a number of technical issues. The primary objective was to determine the increased efficiency of gas recovery of a long horizontal wellbore over that of a vertical wellbore and, more specifically, what improvements can be expected from inducing multiple hydraulic fractures from such a wellbore. This volume contains appendices for: (1) supporting material and procedures for ``data frac`` stimulation of zone 6 using nitrogen and nitrogen foam; (2) supporting material and procedures for stimulation no. 1 nitrogen gas frac on zone no. 1; (3) supporting material and procedures for stimulation no. 2 in zone no. 1 using liquid CO{sub 2}; (4) supporting material and procedures for frac no. 3 on zone no.1 using nitrogen foam and proppant; (5) supporting material and procedures for stimulation no. 4 in zones 2--3 and 4 using nitrogen foam and proppant; (6) supporting materials and procedures for stimulation no. 5 in zones 5 and 8; and (7) fracture diagnostics reports and supporting materials.

  16. Proficiency Testing by Interlaboratory Comparison Performed in 2010-2015 for Neutron Activation Analysis and Other Analytical Techniques

    International Nuclear Information System (INIS)

    2017-12-01

    The IAEA supports its Member States to increase the utilization of their research reactors. Small and medium sized reactors are mostly used for neutron activation analysis (NAA). Although the markets for NAA laboratories have been identified, demonstration of valid analytical results and organizational quality of the work process are preconditions for expanding the stakeholder community, particularly in commercial routine application of this powerful technique. The IAEA has implemented a new mechanism for supporting NAA laboratories in demonstrating their analytical performance by participation in proficiency testing schemes by interlaboratory comparison. This activity makes possible the identification of deviations and non-conformities, their causes and the process to implement effective approaches to eliminate them. Over 30 laboratories participated between 2010 and 2015 in consecutive proficiency tests organized by the IAEA in conjunction with the Wageningen Evaluating Programmes for Analytical Laboratories (WEPAL) to assess their analytical performances. This publication reports the findings and includes lessons learned of this activity. An attached CD-ROM contains many individual participating laboratory papers sharing their individual results and experience gained through this participation.

  17. Test-retest reliability of Physical Activity Neighborhood Environment Scale among urban men and women in Nanjing, China.

    Science.gov (United States)

    Zhao, L; Wang, Z; Qin, Z; Leslie, E; He, J; Xiong, Y; Xu, F

    2018-03-01

    The identification of physical-activity-friendly built environment (BE) constructs is highly useful for physical activity promotion and maintenance. The Physical Activity Neighborhood Environment Scale (PANES) was developed for assessing BE correlates. However, PANES reliability has not been investigated among adults in China. A cross-sectional study. With multistage sampling approaches, 1568 urban adults (aged 35-74 years) were recruited for the initial survey on all 17 items of PANES Chinese version (PANES-CHN), with the survey repeated 7 days later for each participant. Intraclass correlation coefficient (ICC) was used to assess the test-retest reliability of PANES-CHN for each item. Totally, 1551 participants completed both surveys (follow-up rate = 98.9%). Among participants (mean age: 54.7 ± 11.1 years), 47.8% were men, 22.1% were elders, and 22.7% had ≥13 years of education. Overall, the PANES-CHN demonstrated at least substantial reliability with ICCs ranging from 0.66 to 0.95 (core items), from 0.75 to 0.95 (recommended items), and from 0.78 to 0.87 (optional items). Similar outcomes were observed when data were analyzed by gender or age groups. The PANES-CHN has excellent test-retest reliability and thus has valuable utility for assessing urban BE attributes among Chinese adults. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  18. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    George, A.C.; Knutson, E.O.; Tu, K.W.; Fisenne, I.M.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC). There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is -3

  19. Low activation steels welding with PWHT and coating for ITER test blanket modules and DEMO

    International Nuclear Information System (INIS)

    Aubert, P.; Tavassoli, F.; Rieth, M.; Diegele, E.; Poitevin, Y.

    2011-01-01

    EUROFER weldability is investigated in support of the European material properties database and TBM manufacturing. Electron Beam, Hybrid, laser and narrow gap TIG processes have been carried out on the EUROFER-97 steel (thickness up to 40 mm), a reduced activation ferritic-martensitic steel developed in Europe. These welding processes produce similar welding results with high joint coefficients and are well adapted for minimizing residual distortions. The fusion zones are typically composed of martensite laths, with small grain sizes. In the heat-affected zones, martensite grains contain carbide precipitates. High hardness values are measured in all these zones that if not tempered would degrade toughness and creep resistance. PWHT developments have driven to a one-step PWHT (750 o C/3 h), successfully applied to joints restoring good material performances. It will produce less distortion levels than a full austenitization PWHT process, not really applicable to a complex welded structure such as the TBM. Different tungsten coatings have been successfully processed on EUROFER material. It has shown no really effect on the EUROFER base material microstructure.

  20. Low activation steels welding with PWHT and coating for ITER test blanket modules and DEMO

    Science.gov (United States)

    Aubert, P.; Tavassoli, F.; Rieth, M.; Diegele, E.; Poitevin, Y.

    2011-02-01

    EUROFER weldability is investigated in support of the European material properties database and TBM manufacturing. Electron Beam, Hybrid, laser and narrow gap TIG processes have been carried out on the EUROFER-97 steel (thickness up to 40 mm), a reduced activation ferritic-martensitic steel developed in Europe. These welding processes produce similar welding results with high joint coefficients and are well adapted for minimizing residual distortions. The fusion zones are typically composed of martensite laths, with small grain sizes. In the heat-affected zones, martensite grains contain carbide precipitates. High hardness values are measured in all these zones that if not tempered would degrade toughness and creep resistance. PWHT developments have driven to a one-step PWHT (750 °C/3 h), successfully applied to joints restoring good material performances. It will produce less distortion levels than a full austenitization PWHT process, not really applicable to a complex welded structure such as the TBM. Different tungsten coatings have been successfully processed on EUROFER material. It has shown no really effect on the EUROFER base material microstructure.

  1. Low activation steels welding with PWHT and coating for ITER test blanket modules and DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Aubert, P., E-mail: Philippe.aubert@cea.fr [CEA Saclay, DEN/DM2S, F-91191 Gif sur Yvette (France); Tavassoli, F. [CEA Saclay, DEN/DMN, F-91191 Gif sur Yvette (France); Rieth, M. [KIT, IMF I, Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany); Diegele, E.; Poitevin, Y. [Fusion for Energy (F4E), C/Josep Pla 2 - Ed. B3, 08019 Barcelona (Spain)

    2011-02-15

    EUROFER weldability is investigated in support of the European material properties database and TBM manufacturing. Electron Beam, Hybrid, laser and narrow gap TIG processes have been carried out on the EUROFER-97 steel (thickness up to 40 mm), a reduced activation ferritic-martensitic steel developed in Europe. These welding processes produce similar welding results with high joint coefficients and are well adapted for minimizing residual distortions. The fusion zones are typically composed of martensite laths, with small grain sizes. In the heat-affected zones, martensite grains contain carbide precipitates. High hardness values are measured in all these zones that if not tempered would degrade toughness and creep resistance. PWHT developments have driven to a one-step PWHT (750 {sup o}C/3 h), successfully applied to joints restoring good material performances. It will produce less distortion levels than a full austenitization PWHT process, not really applicable to a complex welded structure such as the TBM. Different tungsten coatings have been successfully processed on EUROFER material. It has shown no really effect on the EUROFER base material microstructure.

  2. First tests of a novel radiation hard CMOS sensor process for Depleted Monolithic Active Pixel Sensors

    International Nuclear Information System (INIS)

    Pernegger, H.; Hoorne, J.W. van; Kugathasan, T.; Musa, L.; Riedler, P.; Riegel, C.; Schaefer, D.; Schioppa, E.J.; Snoeys, W.; Bates, R.; Buttar, C.; Maneuski, D.; Dalla, M.; Sbarra, C.

    2017-01-01

    The upgrade of the ATLAS [1] tracking detector for the High-Luminosity Large Hadron Collider (LHC) at CERN requires novel radiation hard silicon sensor technologies. Significant effort has been put into the development of monolithic CMOS sensors but it has been a challenge to combine a low capacitance of the sensing node with full depletion of the sensitive layer. Low capacitance brings low analog power. Depletion of the sensitive layer causes the signal charge to be collected by drift sufficiently fast to separate hits from consecutive bunch crossings (25 ns at the LHC) and to avoid losing the charge by trapping. This paper focuses on the characterization of charge collection properties and detection efficiency of prototype sensors originally designed in the framework of the ALICE Inner Tracking System (ITS) upgrade [2]. The prototypes are fabricated both in the standard TowerJazz 180nm CMOS imager process [3] and in an innovative modification of this process developed in collaboration with the foundry, aimed to fully deplete the sensitive epitaxial layer and enhance the tolerance to non-ionizing energy loss. Sensors fabricated in standard and modified process variants were characterized using radioactive sources, focused X-ray beam and test beams before and after irradiation. Contrary to sensors manufactured in the standard process, sensors from the modified process remain fully functional even after a dose of 10"1"5 n _e_q/cm"2, which is the the expected NIEL radiation fluence for the outer pixel layers in the future ATLAS Inner Tracker (ITk) [4].

  3. Low activation steels welding with PWHT and coating for ITER Test Blanket Modules and DEMO

    International Nuclear Information System (INIS)

    Aubert, P.; Tavassoli, F.; Rieth, M.; Diegele, E.; Poitevin, Y.

    2009-01-01

    Eurofer weldability is established for data base assessment and TBM manufacturing support. Electron Beam, Hybrid (Laser combined with MIG/MAG), Laser and Narrow Gap TIG processes have been carried out on Eurofer Low activation steel. Electron Beam produces very narrow fusion zone width, in the range of 3 to 4 mm, and too strong enhanced weld shape with brittle joints with δ-ferrite and pores. This process is considered only for low penetration depth (cooling plates). The other processes produce 2 families of similar results: one for Hybrid (MIG + Laser) and Laser processes, and a second one for TIG and Narrow Gap TIG processes. The first one procures less distortion and coarsened fusion zone, due to higher cooling rate. For all the welding processes, high hardness values, increasing brittleness and softening effects in the Heat Affected Zone are observed for each welding configuration that could signal creep problems. The Fusion Zones are typically composed of martensite laths, with small grain sizes. In the Heat Affected Zones, martensite grains are observed with carbide precipitation. Eurofer filler wire with optimized chemical composition is developed for producing welds with good properties and high joint coefficient value. To restore mechanical properties after welding, PWHT have been developed: single step for the first family and 2 steps for the second one. Distortions of different mock-ups with and without PWHT have been managed to assess manufacturing rules and clamping devices. Welding data base has thus been established. W coating on the TBM structure has shown no strong effect on the TBM structure. (author)

  4. Performance test results of noninvasive characterization of Resource Conservation and Recovery Act surrogate waste by prompt gamma neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gehrke, R.J.; Streier, G.G.

    1997-03-01

    During FY-96, a performance test was carried out with funding from the Mixed Waste Focus Area (MWFA) of the Department of Energy (DOE) to determine the noninvasive elemental assay capabilities of commercial companies for Resource Conservation and Recovery Act (RCRA) metals present in 8-gal drums containing surrogate waste. Commercial companies were required to be experienced in the use of prompt gamma neutron activation analysis (PGNAA) techniques and to have a prototype assay system with which to conduct the test assays. Potential participants were identified through responses to a call for proposals advertised in the Commerce Business Daily and through personal contacts. Six companies were originally identified. Two of these six were willing and able to participate in the performance test, as described in the test plan, with some subsidizing from the DOE MWFA. The tests were conducted with surrogate sludge waste because (1) a large volume of this type of waste awaits final disposition and (2) sludge tends to be somewhat homogeneous. The surrogate concentrations of the above RCRA metals ranged from {approximately} 300 ppm to {approximately} 20,000 ppm. The lower limit was chosen as an estimate of the expected sensitivity of detection required by noninvasive, pretreatment elemental assay systems to be of value for operational and compliance purposes and to still be achievable with state-of-the-art methods of analysis. The upper limit of {approximately} 20,000 ppm was chosen because it is the opinion of the author that assay above this concentration level is within current state-of-the-art methods for most RCRA constituents. This report is organized into three parts: Part 1, Test Plan to Evaluate the Technical Status of Noninvasive Elemental Assay Techniques for Hazardous Waste; Part 2, Participants` Results; and Part 3, Evaluation of and Comments on Participants` Results.

  5. Applicability of the Monocyte Activation Test (MAT) in the quality control of the 17DD yellow fever vaccine.

    Science.gov (United States)

    de Mattos, Katherine Antunes; Navega, Elaine Cristina Azevedo; Silva, Vitor Fernandes; Almeida, Alessandra Santos; da Silva, Cristiane Caldeira; Presgrave, Octavio Augusto França; Junior, Daniel da Silva Guedes; Delgado, Isabella Fernandes

    2018-03-01

    The need for alternatives to animal use in pyrogen testing has been driven by the Three Rs concept. This has resulted in the inclusion of the monocyte activation test (MAT) in the European Pharmacopoeia, 2010. However, some technical and regulatory obstacles must be overcome to ensure the effective implementation of the MAT by the industry, especially for the testing of biological products. The yellow fever (YF) vaccine (17DD-YFV) was chosen for evaluation in this study, in view of: a) the 2016-2018 outbreak of YF in Brazil; b) the increase in demand for 17DD-YFV doses; c) the complex production process with live attenuated virus; d) the presence of possible test interference factors, such as residual process components (e.g. ovalbumin); and e) the need for the investigation of other pyrogens that are not detectable by the methods prescribed in the YF vaccine monograph. The product-specific testing was carried out by using cryopreserved and fresh whole blood, and IL-6 and IL-1β levels were used as the marker readouts. After assessing the applicability of the MAT on a 1:10 dilution of 17DD-YFV, endotoxin and non-endotoxin pyrogens were quantified in spiked batches, by using the lipopolysaccharide and lipoteichoic acid standards, respectively. The quantitative analysis demonstrated the correlation between the MAT and the Limulus amoebocyte lysate (LAL) assays, with respect to the limits of endotoxin recovery in spiked batches and the detection of no pyrogenic contamination in commercial batches of 17DD-YFV. The data demonstrated the applicability of the MAT for 17DD-YFV pyrogen testing, and as an alternative method that can contribute to biological quality control studies. 2018 FRAME.

  6. Kappa-opioid receptors mediate the antidepressant-like activity of hesperidin in the mouse forced swimming test.

    Science.gov (United States)

    Filho, Carlos B; Del Fabbro, Lucian; de Gomes, Marcelo G; Goes, André T R; Souza, Leandro C; Boeira, Silvana P; Jesse, Cristiano R

    2013-01-05

    The opioid system has been implicated as a contributing factor for major depression and is thought to play a role in the mechanism of action of antidepressants. This study investigated the involvement of the opioid system in the antidepressant-like effect of hesperidin in the mouse forced swimming test. Our results demonstrate that hesperidin (0.1, 0.3 and 1 mg/kg; intraperitoneal) decreased the immobility time in the forced swimming test without affecting locomotor activity in the open field test. The antidepressant-like effect of hesperidin (0.3 mg/kg) in the forced swimming test was prevented by pretreating mice with naloxone (1 mg/kg, a nonselective opioid receptor antagonist) and 2-(3,4-dichlorophenyl)-Nmethyl-N-[(1S)-1-(3-isothiocyanatophenyl)-2-(1-pyrrolidinyl)ethyl] acetamide (DIPPA (1 mg/kg), a selective κ-opioid receptor antagonist), but not with naloxone methiodide (1 mg/kg, a peripherally acting opioid receptor antagonist), naltrindole (3 mg/kg, a selective δ-opioid receptor antagonist), clocinnamox (1 mg/kg, a selective μ-opioid receptor antagonist) or caffeine (3 mg/kg, a nonselective adenosine receptor antagonist). In addition, a sub-effective dose of hesperidin (0.01 mg/kg) produced a synergistic antidepressant-like effect in the forced swimming test when combined with a sub-effective dose of morphine (1 mg/kg). The antidepressant-like effect of hesperidin in the forced swimming test on mice was dependent on its interaction with the κ-opioid receptor, but not with the δ-opioid, μ-opioid or adenosinergic receptors. Taken together, these results suggest that hesperidin possesses antidepressant-like properties and may be of interest as a therapeutic agent for the treatment of depressive disorders. Published by Elsevier B.V.

  7. Performance test results of noninvasive characterization of Resource Conservation and Recovery Act surrogate waste by prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Streier, G.G.

    1997-03-01

    During FY-96, a performance test was carried out with funding from the Mixed Waste Focus Area (MWFA) of the Department of Energy (DOE) to determine the noninvasive elemental assay capabilities of commercial companies for Resource Conservation and Recovery Act (RCRA) metals present in 8-gal drums containing surrogate waste. Commercial companies were required to be experienced in the use of prompt gamma neutron activation analysis (PGNAA) techniques and to have a prototype assay system with which to conduct the test assays. Potential participants were identified through responses to a call for proposals advertised in the Commerce Business Daily and through personal contacts. Six companies were originally identified. Two of these six were willing and able to participate in the performance test, as described in the test plan, with some subsidizing from the DOE MWFA. The tests were conducted with surrogate sludge waste because (1) a large volume of this type of waste awaits final disposition and (2) sludge tends to be somewhat homogeneous. The surrogate concentrations of the above RCRA metals ranged from ∼ 300 ppm to ∼ 20,000 ppm. The lower limit was chosen as an estimate of the expected sensitivity of detection required by noninvasive, pretreatment elemental assay systems to be of value for operational and compliance purposes and to still be achievable with state-of-the-art methods of analysis. The upper limit of ∼ 20,000 ppm was chosen because it is the opinion of the author that assay above this concentration level is within current state-of-the-art methods for most RCRA constituents. This report is organized into three parts: Part 1, Test Plan to Evaluate the Technical Status of Noninvasive Elemental Assay Techniques for Hazardous Waste; Part 2, Participants' Results; and Part 3, Evaluation of and Comments on Participants' Results

  8. Validez, fiabilidad y reproducibilidad de un test incremental en rampa en personas físicamente activas. Validity and reliability of an incremental ramp test for active persons.

    Directory of Open Access Journals (Sweden)

    Benito Peinado, Pedro José

    2005-10-01

    validez alcanzada es de contenido y queda justificada por su inclusión habitual en la determinación de los umbrales en ejercicio en la bibliografía (Yamamoto y col., 1991, Ribas y col., 1994, Chicharro y col., 1995, Lucia y col., 1999.AbstractThe continuous apparition of new gas analysis equipment makes necessary and accurate calibration at the start of any new research. At the start of this study the validity of the Oxicon Pro ® analyser had already been proved (Carter et al. 1999:49, Koskolou y Geladas, 2002, Rietjens et al., 2001, but not the reproducibility of it with the protocol here proposed. With this aim test-retest trials were carried out with a group of subjects’ physically active (Sport Science students from the INEF of Madrid. Ten subjects participate (5 males and 5 females physically active (table I sows the characteristics of the subjects did two effort tests in cicloergometer. The ramp protocol increased 5 Watts every 12 seconds (25 watts•min-1, with a 3 minute worm up and lasting when the normal criteria of maximal effort were shown.The results (Table IV to VIII show the high correlation between the variables of the two tests carried out (from r=0.60 and 0.99 and a determination coefficient for VO2, VCO2 and Load of r2=0.95, 0.94 and 0.97 respectively. Only two variables showed differences between test 1 and 2, the maximal production of VCO2 and the aerobic threshold expressed in hart rate. These differences could be done to the increased load of the second test even thought no significant differences were observed on that parameter. No correlations were observed between performance variables like VO2 max, VO2/kg, Load and Load/kg and the recuperation variables.In conclusion, the studied variables support the validity of the protocol and the analyser used on our future researches.

  9. Further Charpy impact test results of low activation ferritic alloys, irradiated at 430{degrees}C to 67 dpa

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, L.E.; Hamilton, M.L.; Gelles, D.S. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-04-01

    Miniature CVN specimens of four ferritic alloys, GA3X, F82H, GA4X and HT9, have been impact tested following irradiation at 430{degrees}C to 67 dpa. Comparison of the results with those of the previously test