WorldWideScience

Sample records for test study ii

  1. Ocean Thermal Energy Converstion (OTEC) test facilities study program. Final report. Volume II. Part B

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-01-17

    Results are presented of an 8-month study to develop alternative non-site-specific OTEC facilities/platform requirements for an integrated OTEC test program which may include land and floating test facilities. Volume II--Appendixes is bound in three parts (A, B, and C) which together comprise a compendium of the most significant detailed data developed during the study. Part B provides an annotated test list and describes component tests and system tests.

  2. Pulmonary function testing in HTLV-I and HTLV-II infected humans: a cohort study

    Directory of Open Access Journals (Sweden)

    Garratty George

    2003-07-01

    Full Text Available Abstract Background HTLV-I infection has been linked to lung pathology and HTLV-II has been associated with an increased incidence of pneumonia and acute bronchitis. However it is unknown whether HTLV-I or -II infection alters pulmonary function. Methods We performed pulmonary function testing on HTLV-I, HTLV-II and HTLV seronegative subjects from the HTLV outcomes study (HOST, including vital capacity (VC, forced expiratory volume in one second (FEV1, and diffusing lung capacity for carbon monoxide (DLCO corrected for hemoglobin and lung volume. Multivariable analysis adjusted for differences in age, gender, race/ethnicity, height and smoking history. Results Mean (standard deviation pulmonary function values among the 257 subjects were as follows: FVC = 3.74 (0.89 L, FEV1 = 2.93 (0.67 L, DLCOcorr = 23.82 (5.89 ml/min/mmHg, alveolar ventilation (VA = 5.25 (1.20 L and DLCOcorr/VA = 4.54 (0.87 ml/min/mmHg/L. There were no differences in FVC, FEV1 and DLCOcorr/VA by HTLV status. For DLCOcorr, HTLV-I and HTLV-II subjects had slightly lower values than seronegatives, but neither difference was statistically significant after adjustment for confounding. Conclusions There was no difference in measured pulmonary function and diffusing capacity in generally healthy HTLV-I and HTLV-II subjects compared to seronegatives. These results suggest that previously described HTLV-associated abnormalities in bronchoalveolar cells and fluid may not affect pulmonary function.

  3. PISC II: Parametric studies. Effect of defect characteristics on immersion focusing probe testing results

    International Nuclear Information System (INIS)

    Dombret, P.

    1989-09-01

    The results of the Round-Robin trials conducted under the PISC I exercise (1976-1980) showed large discrepancies in the defect detection and sizing capability among different flaws. To identify the causes of such dispersions and quantify the effects, a Parametric Study was included in the PISC II project, taking into consideration most characteristics of planar flaws. A number of steel specimens containing various artificial defects was made available for the measurements. The defects were ultrasonically scanned by standard methods and by some advanced techniques the high performance of which had been established in the PISC Round-Robin Tests. This report deals with the beam focusing technique: 2 MHz 45 0 shear wave transducers have been used in immersion to collect the signals generated by the reference reflectors. The results show that the depth and the size of a defect do not affect significantly its detection and sizing, provided that the natural variation of sensitivity and of beam diameter along the propagation axis is taken into account. On the other hand, parameters such as the orientation and the roughness modify the conditions of impact and interference of the acoustic beam with the defect surface, and therefore strongly influence the energy partition in diffracted and specularly reflected rays. As an example, sharp smooth defects insonified under an angle of 45 0 return to the transducer signals approximately 10 times smaller than the ASME code calibration level

  4. GA(2)LEN skin test study II: clinical relevance of inhalant allergen sensitizations in Europe

    DEFF Research Database (Denmark)

    Burbach, G J; Heinzerling, L M; Edenharter, G

    2009-01-01

    BACKGROUND: Skin prick testing is the standard for diagnosing IgE-mediated allergies. A positive skin prick reaction, however, does not always correlate with clinical symptoms. A large database from a Global Asthma and Allergy European Network (GA(2)LEN) study with data on clinical relevance was ...... the clinical relevance of positive skin prick tests and calls for further studies, which may, ultimately, help increase the positive predictive value of allergy testing.......BACKGROUND: Skin prick testing is the standard for diagnosing IgE-mediated allergies. A positive skin prick reaction, however, does not always correlate with clinical symptoms. A large database from a Global Asthma and Allergy European Network (GA(2)LEN) study with data on clinical relevance...... was used to determine the clinical relevance of sensitizations against the 18 most frequent inhalant allergens in Europe. The study population consisted of patients referred to one of the 17 allergy centres in 14 European countries (n = 3034, median age = 33 years). The aim of the study was to assess...

  5. Testing the Gossamer Albatross II

    Science.gov (United States)

    1980-01-01

    The Gossamer Albatross II is seen here during a test flight at NASA's Dryden Flight Research Center, Edwards, California. The original Gossamer Albatross is best known for completing the first completely human powered flight across the English Channel on June 12, 1979. The Albatross II was the backup craft for the Channel flight. It was fitted with a small battery-powered electric motor and flight instruments for the NASA research program in low-speed flight. NASA completed its flight testing of the Gossamer Albatross II and began analysis of the results in April, 1980. During the six week program, 17 actual data gathering flights and 10 other flights were flown here as part of the joint NASA Langley/Dryden flight research program. The lightweight craft, carrying a miniaturized instrumentation system, was flown in three configurations; using human power, with a small electric motor, and towed with the propeller removed. Results from the program contributed to data on the unusual aerodynamic, performance, stability, and control characteristics of large, lightweight aircraft that fly at slow speeds for application to future high altitude aircraft. The Albatross' design and research data contributed to numerous later high altitude projects, including the Pathfinder.

  6. Radionuclide migration experiments related to an underground nuclear test: II. modeling studies

    International Nuclear Information System (INIS)

    Tompson, A.; Carle, S.F.; Smith, D.K.; Hudson, G.B.; Bruton, C.J.

    2001-01-01

    Full text: The goal of this project is to improve our understanding of water and radionuclide migration in both saturated and unsaturated geologic media by coupling advanced simulation techniques, available characterization data, and radioanalytical measurements in the context of a remarkable field experiment. Between 1975 and 1991, groundwater was steadily pumped from a well adjacent to a 1965 underground test conducted in alluvium at the Nevada Test Site. The experiment was primarily conducted in order to elicit information on radionuclide migration through the saturated zone between the test and the well. The effluent was monitored. discharged to an unlined ditch, and allowed to infiltrate into the ground during flow towards a dry lake, about a kilometer away. The 16 years of pumping and infiltration created an unexpected second experiment in which the migration of the ditch effluent through the 200 meters of unsaturated media, back to the water table, could be studied. Pumping and effluent data are being utilized in conjunction with chemical measurements made in groundwater and a series of numerical models to better understand the movement of radionuclides in the system, both between the test and the well, and between the ditch and the water table. The release of radionuclides away from a testing area will be controlled by local groundwater flow rates, by their dissolution from solidified melt glass produced by the test, and by chemical sorption processes that retard their migration rates in chemically reactive geologic media. Only the more mobile and less reactive radionuclides (e.g.. tritium, 14 C, 36 Cl, 85 Kr, and 129 I) were measured in the well effluent. The movement of these radionuclides through the unsaturated media beneath the ditch will be affected additionally by the capillary nature of moisture movement under unsaturated conditions and by their interaction with and potential mass exchange with the gas (air) phase. Results of numerical simulations

  7. Praxis II mathematics content knowledge test (0061)

    CERN Document Server

    McCune, Ennis Donice

    2007-01-01

    Your guide to a higher score on the Praxis II?: Mathematics Content Knowledge Test (0061) Why CliffsTestPrep Guides? Go with the name you know and trust Get the information you need--fast! Written by test-prep specialists About the contents: Introduction * Overview of the exam * How to use this book * Proven study strategies and test-taking tips Part I: Subject Review * Focused review of all exam topics: arithmetic and basic algebra, geometry, trigonometry, analytic geometry, functions and their graphs, calculus, probability and statistics, discrete mathematics, linear algebra, compute

  8. Advance Noise Control Fan II: Test Rig Fan Risk Management Study

    Science.gov (United States)

    Lucero, John

    2013-01-01

    Since 1995 the Advanced Noise Control Fan (ANCF) has significantly contributed to the advancement of the understanding of the physics of fan tonal noise generation. The 9'x15' WT has successfully tested multiple high speed fan designs over the last several decades. This advanced several tone noise reduction concepts to higher TRL and the validation of fan tone noise prediction codes.

  9. ROSA-II test data report, 6

    International Nuclear Information System (INIS)

    1976-12-01

    Results of the ROSA-II test simulating a loss-of-coolant accident in a light water reactor (LWR) are presented, including the test conditions and interpretation of the phenomena for test runs 411, 314, 315 and 316. (auth.)

  10. Initial proto II pulsed power tests

    International Nuclear Information System (INIS)

    Johnson, D.L.

    1976-01-01

    The Proto II electron beam accelerator is being developed by Sandia Laboratories to study engineering and physics aspects of electron beam pellet fusion. Currently the Marx generator-water capacitor portion of Proto II is undergoing high voltage testing and timing measurements. Eight 112 kJ Marx generators form the primary energy storage system. Each Marx generator pulse charges two parallel 7.5 nF water capacitors to 3 MV. The water capacitors act as intermediate energy storage elements and will transfer their energy to the water insulated pulse-forming lines in 250 ns by means of eight SF 6 gas insulated, trigatron switches. Test data and design considerations of the trigger systems, Marx generators, water capacitors, and trigatron switches are presented

  11. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier

    2010-01-01

    Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated...... and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing...

  12. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben; Mouridsen, Kim; Golay, Xavier

    2009-01-01

    Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated...... and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing...

  13. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study.

    Science.gov (United States)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier

    2010-01-01

    Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing mean displacements of 1.87+/-0.95 mm and rotations of 1.56+/-0.66 degrees . Mean gray matter CBF was 47.4+/-7.5 [ml/100 g/min] with a between-subject standard variation SD(b)=5.5 [ml/100 g/min] and a within-subject standard deviation SD(w)=4.7 [ml/100 g/min]. The corresponding repeatability was 13.0 [ml/100 g/min] and was found to be within the range of previous studies.

  14. The QUASAR reproducibility study, Part II: Results from a multi center Arterial Spin Labeling test-retest Study

    Science.gov (United States)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier

    2009-01-01

    Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed “The QUASAR reproducibility study”. Altogether, 28 sites located in Asia, Europe and North America participated and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing mean displacements of 1.87±0.95mm and rotations of 1.56±0.66°. Mean gray matter CBF was 47.4±7.5 [ml/100g/min] with a between subject standard variation SDb = 5.5 [ml/100g/min] and a within subject standard deviation SDw = 4.7 [ml/100g/min]. The corresponding repeatability was 13.0 [ml/100g/min] and was found to be within the range of previous studies. PMID:19660557

  15. ROSA-II test data report, 11

    International Nuclear Information System (INIS)

    1978-02-01

    Results of the ROSA-II tests simulating a loss-of-coolant accident (LOCA) and effects of an emergency core cooling system (ECCS) in a pressurized water reactor (PWR) are presented including the test conditions and interpretations of the data in test runs 327,328,329 and 330. Each test was performed with large double-ended hot leg break and effect of the break area distribution (break diameter are 25.0 mm at one end and 37.5 mm at the other end of break) and of pump circulation upon coolant flow in the core were studied. The following are the results: In the case of a smaller break on the steam generator side, core cooling was achieved due to upward coolant flow in the core and early reflooding by ACC water injected into the cold leg. In the case of a smaller break area on the vessel side, on the other hand, coolant flow in the core was stagnant and the heater rods were mostly exposed to steam, so that core cooling was not as good. Effect of the coolant circulation by acting pump on the core cooling during a blowdown was not significant except that in a steam generator side small break the core cooling was improved. (auth.)

  16. Test of GERDA Phase II detector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Bode, Tobias; Gusev, Konstantin [Technische Universitaet Muenchen (Germany); Schwingenheuer, Bernhard; Wagner, Victoria [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    The GERDA experiment searches for the lepton number violating neutrinoless double beta decay (0νββ) of {sup 76}Ge. The experiment uses HPGe detectors enriched in {sup 76}Ge as source and detection material. In GERDA Phase I five BEGe detectors were operated successfully. These detectors are distinguished for improved energy resolution and enhanced pulse shape discrimination (PSD) against background events. In Phase II additional 25 BEGe detectors will be installed. New electronics and radio-pure low-mass holders were specially designed for Phase II. Prior to the installation in GERDA all BEGe detectors are tested in their final assembly in the LNGS underground laboratory. This talk presents the mechanics and performance of the GERDA Phase II detector assembly.

  17. Options Study - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    R. Wigeland; T. Taiwo; M. Todosow; W. Halsey; J. Gehin

    2010-09-01

    The Options Study has been conducted for the purpose of evaluating the potential of alternative integrated nuclear fuel cycle options to favorably address the issues associated with a continuing or expanding use of nuclear power in the United States. The study produced information that can be used to inform decisions identifying potential directions for research and development on such fuel cycle options. An integrated nuclear fuel cycle option is defined in this study as including all aspects of the entire nuclear fuel cycle, from obtaining natural resources for fuel to the ultimate disposal of used nuclear fuel (UNF) or radioactive wastes. Issues such as nuclear waste management, especially the increasing inventory of used nuclear fuel, the current uncertainty about used fuel disposal, and the risk of nuclear weapons proliferation have contributed to the reluctance to expand the use of nuclear power, even though it is recognized that nuclear power is a safe and reliable method of producing electricity. In this Options Study, current, evolutionary, and revolutionary nuclear energy options were all considered, including the use of uranium and thorium, and both once-through and recycle approaches. Available information has been collected and reviewed in order to evaluate the ability of an option to clearly address the challenges associated with the current implementation and potential expansion of commercial nuclear power in the United States. This Options Study is a comprehensive consideration and review of fuel cycle and technology options, including those for disposal, and is not constrained by any limitations that may be imposed by economics, technical maturity, past policy, or speculated future conditions. This Phase II report is intended to be used in conjunction with the Phase I report, and much information in that report is not repeated here, although some information has been updated to reflect recent developments. The focus in this Options Study was to

  18. Patch tests with fragrance mix II and its components.

    Science.gov (United States)

    Pónyai, Györgyi; Németh, Ilona; Altmayer, Anita; Nagy, Gabriella; Irinyi, Beatrix; Battyáni, Zita; Temesvári, Erzsébet

    2012-01-01

    Fragrance mix II (FM II) was initiated to detect contact hypersenstitivity (CH) to fragrances that could not have been identified previously. The aim of this multicenter study was to map the frequency of CH to FM II and its components in Hungary. Six centers participated in the survey from 2009 to 2010. A total off 565 patients (434 women and 131 men) with former skin symptoms provoked by scented products were patch tested. The tests were performed with Brial GmbH D-Greven allergens. In the environmental patch test series, FM II, FM I, Myroxylon pereirae, colophonium, wood-tar mix, propolis, and sesquiterpene lactone mix were tested as fragrance allergens. The FM II components (citral, farnesol, coumarin, citronellol, α-hexyl-cinnamaldehyde, and hydroxy-isohexyl-3-cyclohexene-carboxaldehyde [Lyral]) were also tested. Contact hypersenstitivity to any fragrances was detected in 28.8%, to FM II in 17.2% of the patients. Contact hypersenstitivity to hydroxy-isohexyl-3-cyclohexene-carboxaldehyde was observed in 7.3%, to coumarin in 5.1%, to α-hexyl-cinnamaldehyde in 3.5%, to citral in 3.4%, to farnesol in 2.5%, and to citronellol in 1.2%. Of the FM II-positive cases, 48.4% showed isolated CH reaction. The frequency of CH to FM II is 17.2% in the tested, selected Hungarian population. The CH to FM II and its components could not have been revealed without the present test materials.

  19. High temperature turbine technology program. Phase II. Technology test and support studies. Annual technical progress report, January 1, 1979-December 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    Work performed on the High Temperature Turbine Technology Program, Phase II - Technology Test and Support Studies during the period from January 1, 1979 through December 31, 1979 is summarized. Objectives of the program elements as well as technical progress and problems encountered during this Phase II annual reporting period are presented. Progress on design, fabrication and checkout of test facilities and test rigs is described. LP turbine cascade tests were concluded. 350 hours of testing were conducted on the LP rig engine first with clean distillate fuel and then with fly ash particulates injected into the hot gas stream. Design and fabrication of the turbine spool technology rig components are described. TSTR 60/sup 0/ sector combustor rig fabrication and testing are reviewed. Progress in the design and fabrication of TSTR cascade rig components for operation on both distillate fuel and low Btu gas is described. The new coal-derived gaseous fuel synthesizing facility is reviewed. Results and future plans for the supporting metallurgical programs are discussed.

  20. ROSA-II test data report, 13

    International Nuclear Information System (INIS)

    1978-07-01

    Results of the ROSA-II test simulating a loss-of-coolant accident (LOCA) in a PWR are presented, including test conditions and interpretations of phenomena observed in test runs 502, 505, 506 and 507. Development tests were performed to find a more effective ECCS injection method than the existing one based on cold leg injection. A combined injection of hot water into upper plenum in early stage of blowdown and subsequent cold water into lower plenum is the most effective method for a cold leg break. A hot leg injection of a low pressure injection system is effective for direct core cooling and early reflooding. The generalization for actual reactors will require analyses with a reliable code. (auth.)

  1. Tests in Print II: An Index to Tests, Test Reviews, and the Literature on Specific Tests.

    Science.gov (United States)

    Buros, Oscar K., Ed.

    Tests in Print II is a comprehensive, annotated bibliography of all in-print tests published as separates for use with English-speaking subjects. The 1,155 two-column pages list 2,467 tests in print as of early 1974; 16,574 references through 1971 on specific tests; a reprinting of the 1974 APA-AERA-NCME Standards for Educational andPsychological…

  2. LCLS-II CRYOMODULE TRANSPORT SYSTEM TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Huque, Naeem [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Daly, Edward F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); McGee, Michael W. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2018-04-01

    The Cryomodules (CM) for the Linear Coherent Light Source II (LCLS-II) will be shipped to SLAC (Menlo Park, California) from JLab (Newport News, Virginia) and FNAL (Batavia, Illinois). A transportation system has been designed and built to safely transport the CMs over the road. It uses an array of helical isolator springs to attenuate shocks on the CM to below 1.5g in all directions. The system rides on trailers equipped with Air-Ride suspension, which attenuates vibration loads. The prototype LCLS-II CM (pCM) was driven 750 miles to test the transport system; shock loggers recorded the shock attenuation on the pCM and vacuum gauges were used to detect any compromises in beamline vacuum. Alignment measurements were taken before and after the trip to check whether cavity positions had shifted beyond the ± 0.2mm spec. Passband frequencies and cavity gradients were measured at 2K at the Cryomodule Test Facility (CMTF) at JLab to identify any degradation of CM performance after transportation. The transport system was found to have safely carried the CM and is cleared to begin shipments from JLab and FNAL to SLAC.

  3. Pretest Predictions for Phase II Ventilation Tests

    International Nuclear Information System (INIS)

    Yiming Sun

    2001-01-01

    The objective of this calculation is to predict the temperatures of the ventilating air, waste package surface, and concrete pipe walls that will be developed during the Phase II ventilation tests involving various test conditions. The results will be used as inputs to validating numerical approach for modeling continuous ventilation, and be used to support the repository subsurface design. The scope of the calculation is to identify the physical mechanisms and parameters related to thermal response in the Phase II ventilation tests, and describe numerical methods that are used to calculate the effects of continuous ventilation. The calculation is limited to thermal effect only. This engineering work activity is conducted in accordance with the ''Technical Work Plan for: Subsurface Performance Testing for License Application (LA) for Fiscal Year 2001'' (CRWMS M and O 2000d). This technical work plan (TWP) includes an AP-2.21Q, ''Quality Determinations and Planning for Scientific, Engineering, and Regulatory Compliance Activities'', activity evaluation (CRWMS M and O 2000d, Addendum A) that has determined this activity is subject to the YMP quality assurance (QA) program. The calculation is developed in accordance with the AP-3.12Q procedure, ''Calculations''. Additional background information regarding this activity is contained in the ''Development Plan for Ventilation Pretest Predictive Calculation'' (DP) (CRWMS M and O 2000a)

  4. ROSA-II test data report, 10

    International Nuclear Information System (INIS)

    1977-12-01

    Results of the ROSA-II test simulating a loss-of coolant accident (LOCA) in a light water reactor (LWR) are presented, including the test conditions and interpretation of the phenomena for test runs 415, 417, 421 and 422. Even in small break at the cold leg, the core is exposed to void and the temperature rises. In small break of the hot leg, however, core cooling keeps without temperature rise, because there still remains much residual water and upward core flow exists. Direct effect of the HPCI on the depressurization rate is small, but it increases the accumulator injection rate, leading to early core reflooding and early core cooling from upward. Effects of the secondary system depressurization are increase of depressurization and discharge rates of the primary loop, which results in early initiation of the accumulator injection and core reflooding. (auth.)

  5. Passive cannabis smoke exposure and oral fluid testing. II. Two studies of extreme cannabis smoke exposure in a motor vehicle.

    Science.gov (United States)

    Niedbala, R Sam; Kardos, Keith W; Fritch, Dean F; Kunsman, Kenneth P; Blum, Kristen A; Newland, Gregory A; Waga, Joe; Kurtz, Lisa; Bronsgeest, Matth; Cone, Edward J

    2005-10-01

    ng/mL cutoff), and analyzed by GC-MS-MS for THCCOOH (LOD/LOQ = 1.0 ng/mL). Peak oral fluid THC concentrations in passive subjects recorded at the end of cannabis smoke exposure were up to 7.5 ng/mL (Study 1) and 1.2 ng/mL (Study 2). Thereafter, THC concentrations quickly declined to negative levels within 30-45 min in Study 1. It was found that environmentally exposed Collectors contained 3-14 ng/mL in Study 1. When potential contamination during collection was eliminated in Study 2, all passive subjects were negative at screening/confirmation cutoff concentrations throughout the study. Oral fluid specimens from active smokers had peak concentrations of THC approximately 100-fold greater than passive subjects in both studies. Positive oral fluid results were observed for active smokers 0-8 h. Urine analysis confirmed oral fluid results. These studies clarify earlier findings on the effects of passive cannabis smoke on oral fluid results. Oral fluid specimens collected in the presence of cannabis smoke appear to have been contaminated, thereby falsely elevating THC concentrations in oral fluid. The risk of a positive test for THC was virtually eliminated when specimens were collected in the absence of THC smoke.

  6. Permeability and fluid chemistry studies of the Topopah Spring Member of the Paintbrush Tuff, Nevada Test Site: Part II

    International Nuclear Information System (INIS)

    Moore, D.E.; Morrow, C.A.; Byerlee, J.D.

    1985-03-01

    The Topopah Spring Member of the Paintbrush Tuff is being considered as a possible emplacement horizon for the disposal of nuclear waste. The permeability and pore-fluid chemistry of the Topopah Spring Member have been investigated experimentally. The work reported here represents a continuation of previous permeability studies on the Topopah Spring Member. Three experiments were run, to test the effect of pore pressure, sample orientation, and flow direction on permeability and pore fluid chemistry. In the experiments, water flowed either up or down a temperature gradient established across the tuff sample in response to a small pore pressure gradient. The maximum temperature of the gradient was 150 0 C, and the minimum was 43 to 45 0 C. The confining pressure was 100 bars, corresponding to a disposal depth of 400 meters. J13 water was the starting pore fluid. The heated tuff samples showed few changes in permeability from their initial, room-temperature values. In addition, the fluids discharged from both the low and high-temperature sides of the tuff samples were dilute, nearly neutral solutions whose compositions did not differ greatly from the starting J13 compositions. 16 refs., 14 figs., 4 tabs

  7. Report of a Multicenter Phase II Trial Testing a Combination of Biweekly Bevacizumab and Daily Erlotinib in Patients With Unresectable Biliary Cancer: A Phase II Consortium Study

    Science.gov (United States)

    Lubner, Sam J.; Mahoney, Michelle R.; Kolesar, Jill L.; LoConte, Noelle K.; Kim, George P.; Pitot, Henry C.; Philip, Philip A.; Picus, Joel; Yong, Wei-Peng; Horvath, Lisa; Van Hazel, Guy; Erlichman, Charles E.; Holen, Kyle D.

    2010-01-01

    Purpose Biliary cancers overexpress epidermal growth factor receptor (EGFR), and angiogenesis has been correlated with poor outcome. Erlotinib, an EGFR tyrosine kinase inhibitor, and bevacizumab, a vascular endothelial growth factor (VEGF) inhibitor have each been shown to have activity in biliary cancer. The primary objective of this study was to evaluate the response rate by Response Evaluation Criteria in Solid Tumors (RECIST). Secondary end points included overall survival (OS), time to progression (TTP), VEGF levels, and molecular studies of EGFR and k-ras. Patients and Methods Eligible patients had advanced cholangiocarcinoma or gallbladder cancer. Patients were treated with bevacizumab 5 mg/kg intravenously on days 1 and 15 and erlotinib 150 mg by mouth daily on days 1 through 28. Responses were evaluated by RECIST. VEGF levels were collected, and samples were analyzed for EGFR mutation by polymerase chain reaction. Results Fifty-three eligible patients were enrolled at eight sites. Of 49 evaluable patients, six (12%; 95% CI, 6% to 27%) had a confirmed partial response. Stable disease was documented in another 25 patients (51%). Rash was the most common grade 3 toxicity. Four patients had grade 4 toxicities. Median OS was 9.9 months, and TTP was 4.4 months. Low repeats (G k-ras Q38 genotype (wild type) were associated with improved outcomes. Conclusion Combination chemotherapy with bevacizumab and erlotinib showed clinical activity with infrequent grade 3 and 4 adverse effects in patients with advanced biliary cancers. On the basis of preliminary molecular analysis, presence of a k-ras mutation may alter erlotinib efficacy. The combination of bevacizumab and erlotinib may be a therapeutic alternative in patients with advanced biliary cancer. PMID:20530271

  8. Prospective phase II study evaluating the efficacy of swallow ability screening tests and pneumonia prevention using a team approach for elderly patients with gastric cancer.

    Science.gov (United States)

    Miki, Yuichiro; Makuuchi, Rie; Honda, Shinsaku; Tokunaga, Masanori; Tanizawa, Yutaka; Bando, Etsuro; Kawamura, Taiichi; Yurikusa, Takashi; Tanuma, Akira; Terashima, Masanori

    2018-03-01

    Aging partly impairs swallowing function, which is considered a risk factor for postoperative pneumonia (PP). We evaluated the efficacy of a new team-based strategy to reduce the incidence of PP in elderly patients with gastric cancer. This single-center, prospective phase II study included elderly patients (≥75 years old) with gastric cancer undergoing gastric surgery. The primary endpoint was the incidence of Clavien-Dindo grade II or higher PP. Patients were initially screened using three swallowing function screening tests: a symptom questionnaire, the modified water swallow test (MSWT), and the repetitive saliva swallowing test (RSST). All patients were provided standard preoperative oral checks and care and simple neck muscle training. For patients who screened positive, a videofluorographic swallowing study was performed; if an abnormality was found, the patient was given intensive swallowing rehabilitation both pre- and postoperatively. Of 86 eligible patients enrolled, PP developed in 3 (3.5%). The 60% confidence interval of 1.8-6.3% had an upper limit below the prespecified threshold of 7.8%. Positive screening results were found for 19 patients (22.1%) on the symptom questionnaire, 3 (3.5%) on the MSWT, and 1 (1.2%) on the RSST. PP was not observed in any patients who screened positive. In conclusion, although the screening tests we adopted here were not sufficient to identify patients at high risk of aspiration pneumonia, perioperative interventions using a team approach might be effective in reducing the incidence of PP in elderly patients with gastric cancer.

  9. Biodegradation testing of TMI-2 EPICOR-II waste forms

    International Nuclear Information System (INIS)

    Rogers, R.D.; McConnell, J.W. Jr.

    1988-06-01

    ASTM biodegradation tests were conducted on waste forms containing high specific activity ion exchange resins from EPICOR-II prefilters. Those tests were part of a program to test waste forms in accordance with the NRC Branch Technical Position on Waste Form. Small waste forms were manufactured using two different solidification agents, Portland Type I-II cement and vinyl ester-styrene (VES). Ion exchange material was taken from two EPICOR-II prefilters; PF-7, which contained all organic material, and PF-20, which contained organic resins and a layer of inorganic zeolites. Test results showed that the VES waste forms supported microbial growth, while cement waste forms did not support that growth. Growth was also observed adjacent to some VES waste forms. Radiation levels found in the ion exchange resins used in this study were not found to inhibit microbial growth. The extent of degradation of the waste forms could not be determined using the ASTM tests specified by the NRC Branch Technical Position on Waste Form. As a result of this work, a different testing methodology is recommended, which would provide direct verification of waste form capabilities. That methodology would evaluate solidification materials without using the ASTM procedures or subsequent compression testing. The proposed tests would provide exposure to a wide range of microbial species, use appropriately sized specimens, provide for possible use of alternate carbon sources, and extend the test length. Degradation would be determined directly by measuring metabolic activity or specimen weight loss. 16 refs., 15 figs., 3 tabs

  10. STARFIRE-II studies. Summary

    International Nuclear Information System (INIS)

    Baker, C.C.; Brooks, J.N.; Ehst, D.A.; Smith, D.L.; Sze, D.K.

    1985-01-01

    The US Department of Energy's Office of Fusion Energy has initiated several studies during FY-1985 called Tokamak Power System Studies (TPSS). The TPSS is being carried out by several laboratories, universities and industry with the general objective of developing innovative physics and technology concepts to improve the commercial attractiveness of tokamak power reactors. The effort of Argonne National Laboratory, entitled STARFIRE-II, is an effort to update and improve STARFIRE, which was the last comprehensive conceptual design study in the US of a commercial tokamak power plant. The STARFIRE-II effort has developed a number of goals in order to improve fusion commercial power plants based in part on several recent studies. The primary goals for STARFIRE-II are listed

  11. Effect of angiotensin II type I receptor A1166C polymorphism on benazepril action in hypertensive patients: a family-based association test study.

    Science.gov (United States)

    Zhang, Ning; Cui, Huadong; Yang, Lili

    2012-10-01

    Few studies have examined the effect of the angiotensin II type I receptor (AT1R) A1166C polymorphism on the antihypertensive effect of the angiotensin-converting-enzyme inhibitor benazepril in patients with hypertension, and no such studies have performed analysis using the Family-Based Association Test (FBAT), The aim of our study was to examine the association between AT1R A1166C gene polymorphism and the antihypertensive effect of benazepril using the FBAT. A total of 864 patients (aged, 26-62 years) with essential hypertension were identified in an epidemiological survey and enrolled in this study. Blood pressure (BP) was measured before and after 16 days of treatment with benazepril (10 mg/day). The association between the A1166C gene polymorphism and the antihypertensive effect of benazepril was assessed by FBAT. The frequencies of alleles A and C were 95.1% and 4.9%, respectively. FBAT analysis revealed that the C allele was significantly associated with high baseline diastolic BP (Z = 2.041, p = 0.041), decreased systolic BP after treatment (Z = 2.549, p = 0.011), and decreased diastolic BP after treatment (Z = 2.320, p = 0.020). Our results, determined using the FBAT, are the first evidence that the AT1R A1166C polymorphism may increase the antihypertensive effect of benazepril in patients with hypertension.

  12. Test Plan for Hydrogen Getters Project - Phase II

    International Nuclear Information System (INIS)

    Mroz, G.

    1999-01-01

    Hydrogen levels in many transuranic (TRU) waste drums are above the compliance threshold, therefore deeming the drums non-shippable to the Waste Isolation Pilot Plant (WIPP). Hydrogen getters (alkynes and dialkynes) are known to react irreversibly with hydrogen in the presence of certain catalysts. The primary purpose of this investigation is to ascertain the effectiveness of a hydrogen getter in an environment that contains gaseous compounds commonly found in the headspace of drums containing TRU waste. It is not known whether the volatile organic compounds (VOCs) commonly found in the headspace of TRU waste drums will inhibit (''poison'') the effectiveness of the hydrogen getter. The result of this study will be used to assess the feasibility of a hydrogen-getter system, which is capable of removing hydrogen from the payload containers or the Transuranic Package Transporter-II (TRUPACT-II) inner containment vessel to increase the quantity of TRU waste that can be shipped to the WIPP. Phase II for the Hydrogen Getters Project will focus on four primary objectives: Conduct measurements of the relative permeability of hydrogen and chlorinated VOCs through Tedlar (and possibly other candidate packaging materials) Test alternative getter systems as alternatives to semi-permeable packaging materials. Candidates include DEB/Pd/Al2O3 and DEB/Cu-Pd/C. Develop, test, and deploy kinetic optimization model Perform drum-scale test experiments to demonstrate getter effectiveness

  13. The wavelength frame multiplication chopper system for the ESS test beamline at the BER II reactor—A concept study of a fundamental ESS instrument principle

    International Nuclear Information System (INIS)

    Strobl, M.; Bulat, M.; Habicht, K.

    2013-01-01

    Contributing to the design update phase of the European Spallation Source ESS–scheduled to start operation in 2019–a test beamline is under construction at the BER II research reactor at Helmholtz Zentrum Berlin (HZB). This beamline offers experimental test capabilities of instrument concepts viable for the ESS. The experiments envisaged at this dedicated beamline comprise testing of components as well as of novel experimental approaches and methods taking advantage of the long pulse characteristic of the ESS source. Therefore the test beamline will be equipped with a sophisticated chopper system that provides the specific time structure of the ESS and enables variable wavelength resolutions via wavelength frame multiplication (WFM), a fundamental instrument concept beneficial for a number of instruments at ESS. We describe the unique chopper system developed for these purposes, which allows constant wavelength resolution for a wide wavelength band. Furthermore we discuss the implications for the conceptual design for related instrumentation at the ESS

  14. Virtual Sensor Test Instrumentation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Mobitrum has started the development of virtual sensor test instrumentation in Phase I for characterization and measurement of ground testing of propulsion systems....

  15. Operational reliability testing of FBR fuel in EBR-II

    International Nuclear Information System (INIS)

    Asaga, Takeo; Ukai, Shigeharu; Nomura, Shigeo; Shikakura, Sakae

    1991-01-01

    The operational reliability testing of FBR fuel has been conducting in EBR-II as a DOE/PNC collaboration program. This paper reviews the achieved summary of Phase-I test as well as outline of progressing Phase-II test. In Phase-I test, the reliability of FBR fuel pins including 'MONJU' fuel was demonstrated at the event of operational transient. Continued operation of the failed pins was also shown to be feasible without affecting the plant operation. The objectives of the Phase-II test is to extend the data base relating with the operational reliability for long life fuel, and to supply the highly quantitative evaluation. The valuable insight obtained in Phase-II test are considerably expected to be useful toward the achievement of commercial FBR. (author)

  16. Fortran Testing and Refactoring Infrastructure, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Tech-X proposes to develop a comprehensive Fortran testing and refactoring infrastructure that allows developers and scientists to leverage the benefits of...

  17. Horns Rev II, 2-D Model Tests

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Frigaard, Peter

    This report present the results of 2D physical model tests carried out in the shallow wave flume at Dept. of Civil Engineering, Aalborg University (AAU), on behalf of Energy E2 A/S part of DONG Energy A/S, Denmark. The objective of the tests was: to investigate the combined influence of the pile...... diameter to water depth ratio and the wave hight to water depth ratio on wave run-up of piles. The measurements should be used to design access platforms on piles....

  18. Compilation of radiation damage test data. II

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Stolarz-Izycka, A.

    1979-01-01

    This report summarizes radiation damage test data on thermosetting and thermoplastic resins, with the main emphasis on epoxy resins used for magnet coil insulations. Also, other materials such as polyesters, phenolics, polyurethanes, silicones, etc., are represented. The materials have been irradiated in a nuclear reactor to integrated absorbed doses between 5x10 6 Gy and 1x10 8 Gy. The mechanical properties, e.g. the flexural strength, deflection at break, and tangent modulus of elasticity, have been measured on irradiated and non-irradiated samples. The results are given as variation of these parameters versus absorbed dose and are presented in the form of tables and graphs. The tested materials are catalogued in alphabetical order. (Auth.)

  19. HANARO fuel irradiation test (II): revision

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, D. S.; Kim, H.; Chae, H. T.; Lee, C. S.; Kim, B. G.; Lee, C. B

    2001-04-01

    In order to fulfill the requirement to prove HANARO fuel integrity when irradiated at a power greater than 112.8 kW/m, which was imposed during HANARO licensing, and to verify the irradiation performance of HANARO fuel, the in-pile irradiation test of HANARO fuel has been performed. Two types of test fuel, the un-instrumented Type A fuel for higher burnup irradiation in shorter period than the driver fuel and the instrumented Type B fuel for higher linear heat rate and precise measurement of irradiation conditions, have been designed and fabricated. The test fuel assemblies were irradiated in HANARO. The two Type A fuel assemblies were intended to be irradiated to medium and high burnup and have been discharged after 69.9 at% and 85.5 at% peak burnup, respectively. Type B fuel assembly was intended to be irradiated at high power with different instrumentations and achieved a maximum power higher than 120 kW/m without losing its integrity and without showing any irregular behavior. The Type A fuel assemblies were cooled for about 6 months and transported to the IMEF(Irradiated Material Examination Facility) for consequent evaluation. Detailed non-destructive and destructive PIE (Post-Irradiation Examination), such as the measurement of burnup distribution, fuel swelling, clad corrosion, dimensional changes, fuel rod bending strength, micro-structure, etc., has been performed. The measured results have been analysed/compared with the predicted performance values and the design criteria. It has been verified that HANARO fuel maintains proper in-pile performance and integrity even at the high power of 120 kw/m up to the high burnup of 85 at%. This report is the revision of KAERI/TR-1816/2001 on the irradiation test for HANARO fuel.

  20. Evolution of thermal-hydraulics testing in EBR-II

    International Nuclear Information System (INIS)

    Golden, G.H.; Planchon, H.P.; Sackett, J.I.; Singer, R.M.

    1987-01-01

    A thermal-hydraulics testing and modeling program has been underway at the Experimental Breeder Reactor-II (EBR-II) for 12 years. This work culminated in two tests of historical importance to commercial nuclear power, a loss of flow without scram and a loss of heat sink wihout scram, both from 100% initial power. These tests showed that natural processes will shut EBR-II down and maintain cooling without automatic control rod action or operator intervention. Supporting analyses indicate that these results are characteristic of a range of sizes of liquid metal cooled reactors (LMRs), if these reactors use metal driver fuel. This type of fuel is being developed as part of the Integral Fast Reactor Program at Argonne National Laboratory. Work is now underway at EBR-II to exploit the inherent safety of metal-fueled LMRs with regard to development of improved plant control strategies. (orig.)

  1. Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: A practical review for clinical researchers-Part II. general guidance and tips

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi; Park, Seong Ho; Lee, June Young

    2015-01-01

    Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies

  2. Mechanical simulations of sandia II tests OECD ISP 48 benchmark

    International Nuclear Information System (INIS)

    Ghavamian, Sh.; Courtois, A.; Valfort, J.-L.; Heinfling, G.

    2005-01-01

    This paper illustrates the work carried out by EDF within the framework of ISP48 post-test analysis of NUPEC/NRCN 1:4-scale model of a prestressed pressure containment vessel of a nuclear power plant. EDF as a participant of the International Standard Problem n degree 8 has performed several simulations to determine the ultimate response of the scale model. To determine the most influent parameter in such an analysis several studies were carried out. The mesh was built using a parametric tool to measure the influence of discretization on results. Different material laws of concrete were also used. The purpose of this paper is to illustrate the ultimate behaviour of SANDIA II model obtained by Code-Asterwith comparison to tests records, and also to share the lessons learned from the parametric computations and precautions that must be taken. (authors)

  3. Catch-up validation study of an in vitro skin irritation test method based on an open source reconstructed epidermis (phase II).

    Science.gov (United States)

    Groeber, F; Schober, L; Schmid, F F; Traube, A; Kolbus-Hernandez, S; Daton, K; Hoffmann, S; Petersohn, D; Schäfer-Korting, M; Walles, H; Mewes, K R

    2016-10-01

    To replace the Draize skin irritation assay (OECD guideline 404) several test methods based on reconstructed human epidermis (RHE) have been developed and were adopted in the OECD test guideline 439. However, all validated test methods in the guideline are linked to RHE provided by only three companies. Thus, the availability of these test models is dependent on the commercial interest of the producer. To overcome this limitation and thus to increase the accessibility of in vitro skin irritation testing, an open source reconstructed epidermis (OS-REp) was introduced. To demonstrate the capacity of the OS-REp in regulatory risk assessment, a catch-up validation study was performed. The participating laboratories used in-house generated OS-REp to assess the set of 20 reference substances according to the performance standards amending the OECD test guideline 439. Testing was performed under blinded conditions. The within-laboratory reproducibility of 87% and the inter-laboratory reproducibility of 85% prove a high reliability of irritancy testing using the OS-REp protocol. In addition, the prediction capacity was with an accuracy of 80% comparable to previous published RHE based test protocols. Taken together the results indicate that the OS-REp test method can be used as a standalone alternative skin irritation test replacing the OECD test guideline 404. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. HANARO fuel irradiation test(II)

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, D. S.; Kim, H. R.; Chae, H. T.; Lee, B. C.; Lee, C. S.; Kim, B. G.; Lee, C. B.; Hwang, W

    2001-04-01

    In order to fulfill the requirement to prove HANARO fuel integrity when irradiated at a power greater than 112.8 kW/m, which was imposed during HANARO licensing, and to verify the irradiation performance of HANARO fuel, the in-pile irradiation test of HANARO fuel has been performed. Two types of test fuel, the un-instrumented Type A fuel for higher burnup irradiation in shorter period than the driver fuel and the instrumented Type B fuel for higher linear heat rate and precise measurement of irradiation conditions, have been designed and fabricated. The test fuel assemblies were irradiated in HANARO. The two Type A fuel assemblies were intended to be irradiated to medium and high burnup and have been discharged after 69.9 at% and 85.5 at% peak burnup, respectively. Type B fuel assembly was intended to be irradiatied at high power with different instrumentations and achieved a maximum power higher than 120 kW/m without losing its integrity and without showing any irregular behavior. The Type A fuel assemblies were cooled for about 6 months and transported to the IMEF(Irradiated Material Examination Facility) for consequent evaluation. Detailed non-destructive and destructive PIE (Post-Irradiation Examination), such as the measurement of burnup distribution, fuel swelling, clad corrosion, dimensional changes, fuel rod bending strength, micro-structure, etc., has been performed. The measured results have been analysed/compared with the predicted performance values and the design criteria. It has been verified that HANARO fuel maintains proper in-pile performance and integrity even at the high power of 120 kw/m up to the high burnup of 85 at%.

  5. Detection of antibiotic residues in food by Charm II test

    International Nuclear Information System (INIS)

    Addali, Mohamed

    2014-01-01

    Antibiotics are used in food to: -therapy and prophylaxis, -increase the productivity of the food producing animals. The presence of antimicrobial residues: -constitutes a potential human health hazard. has significant impact on international food trade. has implications on technological process in dairy industry. Detection of antibiotic residues is of great interest. It helps protect humans against the effects of such residues, the more it can support the participation of our country in international trade. Charm II test is one of the methods of detection of antimicrobial residues. The tests utilize microbial or antibody receptor assay technology. The sample is incubated with a binding agent (microbial cells with specific receptor sites or with specific antibodies attached) and a tracer (the radio-labeled version of the antibiotic to be detected). The amount of tracer on the binding agent is measured using a scintillation counter and is compared to a pre-determined cut-off or control point. If contaminating antibiotic is present, it will prevent the binding of the tracer by occupying the receptors on the binding agent. The less labeled tracer detected, the more contaminating antibiotic there is present in the sample. This work, carried out at the Radiochemical Laboratory of the National Centre of Nuclear Science and Technology, has two parts: 1/ The first is reserved to a literature review provides an overview on antibiotics and the charm II method. 2/ The second is devoted to the experimental study and presentation of results.

  6. Pressurized helium II-cooled magnet test facility

    International Nuclear Information System (INIS)

    Warren, R.P.; Lambertson, G.R.; Gilbert, W.S.; Meuser, R.B.; Caspi, S.; Schafer, R.V.

    1980-06-01

    A facility for testing superconducting magnets in a pressurized bath of helium II has been constructed and operated. The cryostat accepts magnets up to 0.32 m diameter and 1.32 m length with current to 3000 A. In initial tests, the volume of helium II surrounding the superconducting magnet was 90 liters. Minimum temperature reached was 1.7 K at which point the pumping system was throttled to maintain steady temperature. Helium II reservoir temperatures were easily controlled as long as the temperature upstream of the JT valve remained above T lambda; at lower temperatures control became difficult. Positive control of the temperature difference between the liquid and cold sink by means of an internal heat source appears necessary to avoid this problem. The epoxy-sealed vessel closures, with which we have had considerable experience with normal helium vacuum, also worked well in the helium II/vacuum environment

  7. Extension of the ACE solar panels is tested in SAEF-II

    Science.gov (United States)

    1997-01-01

    Extension of the solar panels is tested on the Advanced Composition Explorer (ACE) spacecraft in KSC's Spacecraft Assembly and Encapsulation Facility-II (SAEF-II). Scheduled for launch on a Delta II rocket from Cape Canaveral Air Station on Aug. 25, ACE will study low-energy particles of solar origin and high-energy galactic particles. The collecting power of instruments aboard ACE is 10 to 1,000 times greater than anything previously flown to collect similar data by NASA.

  8. Operational Experience from LCLS-II Cryomodule Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Renzhuo [Fermilab; Hansen, Benjamin [Fermilab; White, Michael [Fermilab; Hurd, Joseph [Fermilab; Atassi, Omar Al [Fermilab; Bossert, Richard [Fermilab; Pei, Liujin [Fermilab; Klebaner, Arkadiy [Fermilab; Makara, Jerry [Fermilab; Theilacker, Jay [Fermilab; Kaluzny, Joshua [Fermilab; Wu, Genfa [Fermilab; Harms, Elvin [Fermilab

    2017-07-01

    This paper describes the initial operational experience gained from testing Linac Coherent Light Source II (LCLS-II) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). Strategies for a controlled slow cooldown to 100 K and a fast cooldown past the niobium superconducting transition temperature of 9.2 K will be described. The test stand for the cryomodules at CMTF is sloped to match gradient in the LCLS-II tunnel at Stanford Linear Accelerator (SLAC) laboratory, which adds an additional challenge to stable liquid level control. Control valve regulation, Superconducting Radio-Frequency (SRF) power compensation, and other methods of stabilizing liquid level and pressure in the cryomodule 2.0 K SRF cavity circuit will be discussed. Several different pumping configurations using cold compressors and warm vacuum pumps have been used on the cryomodule 2.0 K return line and the associated results will be described.

  9. Operational experience from LCLS-II cryomodule testing

    Science.gov (United States)

    Wang, R.; Hansen, B.; White, M.; Hurd, J.; Atassi, O. Al; Bossert, R.; Pei, L.; Klebaner, A.; Makara, J.; Theilacker, J.; Kaluzny, J.; Wu, G.; Harms, E.

    2017-12-01

    This paper describes the initial operational experience gained from testing Linac Coherent Light Source II (LCLS-II) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). Strategies for a controlled slow cooldown to 100 K and a fast cooldown past the niobium superconducting transition temperature of 9.2 K will be described. The test stand for the cryomodules at CMTF is sloped to match gradient in the LCLS-II tunnel at Stanford Linear Accelerator (SLAC) laboratory, which adds an additional challenge to stable liquid level control. Control valve regulation, Superconducting Radio-Frequency (SRF) power compensation, and other methods of stabilizing liquid level and pressure in the cryomodule 2.0 K SRF cavity circuit will be discussed. Several different pumping configurations using cold compressors and warm vacuum pumps have been used on the cryomodule 2.0 K return line and the associated results will be described.

  10. Search for cosmic ray origins by the study of supernova remnants associated with molecular clouds with HESS and test of HESS II sampling system

    International Nuclear Information System (INIS)

    Fiasson, A.

    2008-03-01

    The H.E.S.S. telescope (High energy Stereoscopic System), located in Namibia, is currently the most efficient for the observation of very high energy (VHE) gamma-ray sources. It is composed of 4 large diameter telescopes working in stereoscopic mode and allows an unequaled survey of the galactic plane at these extreme wavelengths. The H.E.S.S. experiment showed the presence of high energy particles up to 100 TeV within supernova remnant. This astrophysical objects are believed to be the main particle accelerator within the Galaxy. However, the particle nature remains unclear. This thesis presents a new observational approach in order to show hadronic particles acceleration through diffusive shock within supernova remnant. A search of supernova remnant associated with molecular cloud have been led within the HESS source catalog and the H.E.S.S. observations. An analysis of the new VHE gamma-ray source in Monoceros and its interpretation are presented. As well, the analysis and interpretation of new observations of the unidentified source HESS J1745-303 are presented. The multi-wavelength analysis of the new source HESS J1714-385, coincident with the supernova remnant CTB37A is presented. A contribution to the H.E.S.S. phase II building is also presented. This second phase consists in the building of a fifth telescope at the center of the existing system. The series tests of the new camera sampling system are reported. (author)

  11. Partial Discharge Tests using the Cigré II method

    DEFF Research Database (Denmark)

    Casale, M. Di Lorenzo del; Schifani, R.; Holbøll, Joachim

    2000-01-01

    In this paper, the results of an experimental project on insulating material aging, performed in both Denmark and Italy, are reported. This study was concerned with partial discharge (PD) behavior at temperatures between 30 and 80°C using CIGRE method II. The material tested was a commercial...... polymethylmethacrylate (PMMA) which was chosen not for its good dielectric properties but rather because much of its discharge resistance data at ambient temperature is already well documented. A description is given of the theoretical and experimental methodology followed in this work. Mixed Weibull analysis techniques...... in terms of the PD amplitude and phase distribution characteristics were employed to distinguish the presence of different aging mechanisms. Such a difference was observed at 30 and at 80°C. At 30°C the analysis inferred a single discharge aging process acting until breakdown, while at 80°C the results...

  12. Testing of a one dimensional model for Field II calibration

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2008-01-01

    Field II is a program for simulating ultrasound transducer fields. It is capable of calculating the emitted and pulse-echoed fields for both pulsed and continuous wave transducers. To make it fully calibrated a model of the transducer’s electro-mechanical impulse response must be included. We...... examine an adapted one dimensional transducer model originally proposed by Willatzen [9] to calibrate Field II. This model is modified to calculate the required impulse responses needed by Field II for a calibrated field pressure and external circuit current calculation. The testing has been performed...... to the calibrated Field II program for 1, 4, and 10 cycle excitations. Two parameter sets were applied for modeling, one real valued Pz27 parameter set, manufacturer supplied, and one complex valued parameter set found in literature, Alguer´o et al. [11]. The latter implicitly accounts for attenuation. Results show...

  13. 33 CFR 159.126 - Coliform test: Type II devices.

    Science.gov (United States)

    2010-07-01

    ... follows: During each of the 10 test days, one sample must be taken at the beginning, middle and end of an 8-consecutive hour period with one additional sample taken immediately following the peak capacity...: Type II devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...

  14. Operating and test experience of EBR-II

    International Nuclear Information System (INIS)

    Sackett, J.I.

    1991-01-01

    EBR-II has operated for 27 years, the longest for any Liquid Metal Reactor (LMR) power plant. During that time, much has been learned about successful LMR operation and design. The basic lesson is that conservatism in design can pay significant dividends in operating reliability. Furthermore, such conservatism need not mean high cost. The EBR-II system emphasizes simplicity, minimizing the number of valves in the heat transport system, for example, and simplifying the primary heat-transport-system layout. Another lesson is that emphasizing reliability of the steam generating system at the sodium-water interface (by using duplex tubes in the case of EBR-II) has been well worth the higher initial costs; no problems with leakage have been encountered in EBR-II's operating history. Locating spent fuel storage in the primary tank and providing for decay heat removal by natural connective flow have also been contributors to EBR-II's success. The ability to accommodate loss of forced cooling or loss of heat sink passively has resulted in benefits for simplification, primarily through less reliance on emergency power and in not requiring the secondary sodium or steam systems to be safety grade. Also, the 'piped-pool' arrangement minimizes thermal stress to the primary tank and enhances natural convective flow. These benefits have been realized through a history of operation that has seen EBR-II evolve through four major phases in its test programs, culminating in its present mission as the Integral Fast Reactor (IFR) prototype. (author)

  15. Synthesis and spectroscopic studies of biologically active tetraazamacrocyclic complexes of Mn(II, Co(II, Ni(II, Pd(II and Pt(II

    Directory of Open Access Journals (Sweden)

    Monika Tyagi

    2014-01-01

    Full Text Available Complexes of Mn(II, Co(II, Ni(II, Pd(II and Pt(II were synthesized with the macrocyclic ligand, i.e., 2,3,9,10-tetraketo-1,4,8,11-tetraazacycoletradecane. The ligand was prepared by the [2 + 2] condensation of diethyloxalate and 1,3-diamino propane and characterized by elemental analysis, mass, IR and 1H NMR spectral studies. All the complexes were characterized by elemental analysis, molar conductance, magnetic susceptibility measurements, IR, electronic and electron paramagnetic resonance spectral studies. The molar conductance measurements of Mn(II, Co(II and Ni(II complexes in DMF correspond to non electrolyte nature, whereas Pd(II and Pt(II complexes are 1:2 electrolyte. On the basis of spectral studies an octahedral geometry has been assigned for Mn(II, Co(II and Ni(II complexes, whereas square planar geometry assigned for Pd(II and Pt(II. In vitro the ligand and its metal complexes were evaluated against plant pathogenic fungi (Fusarium odum, Aspergillus niger and Rhizoctonia bataticola and some compounds found to be more active as commercially available fungicide like Chlorothalonil.

  16. NNWSI Phase II materials interaction test procedure and preliminary results

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1985-01-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) project is investigating the volcanic tuff beds of Yucca Mountain, Nevada, as a potential location for a high-level radioactive waste repository. This report describes a test method (Phase II) that has been developed to measure the release of radionuclides from the waste package under simulated repository conditions, and provides information on materials interactions that may occur in the repository. The results of 13 weeks of testing using the method are presented, and an analog test is described that investigates the relationship between the test method and expected repository conditions. 9 references, 10 figures, 11 tables

  17. The pressure and leak tests in Atucha II

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This work deals with the pressure and leak tests of the containment sphere in the Atucha II Nuclear Power Plant's reactor building. This sphere is a metallic container, made in highly resistant steel plate, that is, built for providing the plant with a biological and structural barrier, which -in turn- provides safety and environmental protection. The applicable rules for these tests establish that the containment erection must be complete and in equivalent conditions to those that will prevail during the NPP operation. Particularly, pressure tests were carried out for assessing the structural condition of the sphere, while the leak test is aimed at the detection of tentative leaks [es

  18. Multifrequency tests in the EBR-II reactor plant

    International Nuclear Information System (INIS)

    Feldman, E.E.; Mohr, D.; Gross, K.C.

    1989-01-01

    A series of eight multifrequency tests was conducted on the Experimental Breeder Reactor II. In half of the tests a control rod was oscillated and in the other half the controller input voltage to the intermediate-loop-sodium pump was perturbed. In each test the input disturbance consisted of several superimposed single-frequency sinusoidal harmonics of the same fundamental. The tests are described along with the theoretical and practical aspects of their development and design. Samples of measured frequency responses are also provided for both the reactor and the power plant. 22 refs., 5 figs., 2 tabs

  19. Heater test planning for the Near Surface Test Facility at the Hanford reservation. Volume II. Appendix

    International Nuclear Information System (INIS)

    DuBois, A.; Binnall, E.; Chan, T.; McEvoy, M.; Nelson, P.; Remer, J.

    1979-04-01

    Volume II contains the following information: theoretical support for radioactive waste storage projects - development of data analysis methods and numerical models; injectivity temperature profiling as a means of permeability characterization; geophysical holes at the Near Surface Test Facility (NSTF), Hanford; proposed geophysical and hydrological measurements at NSTF; suggestions for characterization of the discontinuity system at NSTF; monitoring rock property changes caused by radioactive waste storage using the electrical resistivity method; microseismic detection system for heated rock; Pasco Basin groundwater contamination study; a letter to Mark Board on Gable Mountain Faulting; report on hydrofracturing tests for in-situ stress measurement, NSTF, Hole DC-11, Hanford Reservation; and borehole instrumentation layout for Hanford Near Surface Test Facility

  20. Results of tests with open fuel in KNK II

    International Nuclear Information System (INIS)

    Schmitz, G.

    1987-03-01

    For the operation of Liquid Metal Cooled Fast Breeder Reactors with cladding failures the consequences of increased contamination by fission products and fuel and the possibility of failure propagation to adjacent fuel pins due to fuel swelling have to be envisaged. To clarify some of these problems a KNK II test program involving open fuel was defined with the first experiments of this program being performed between October 1981 and May 1984. After the description of the test equipment and of the test program, the results will be presented on delayed neutron measurements, fission gas measurements and post irradiation examinations. The report will conclude with a discussion of the results [de

  1. Synthesis, characterization and thermal studies of nickel (II), copper (II), zinc (II) and cadmium (II) complexes with some mixed ligands

    International Nuclear Information System (INIS)

    Mitra, Samiran; Kundu, Parimal; Singh, Rajkumar Bhubon

    1998-01-01

    Dichloro-(DCA) and trichloroacetate(TCA) -cyclic ligand morpholine (Morph)/thiomorpholine (Tmorph)/methylmorpholine (Mmorph)/dimethyl-piperazine (DMP) complexes of nickel (II), copper (II), zinc (II) and cadmium (II) with the compositions [Ni(tmorph) 2 (DCA) 2 ], [Ni(tmorph) 2 (TCA) 2 ].2H 2 O, [Cu(DMP) 2 (TCA) 2 ],[ML 2 X 2 ].nH 2 O where M=Zn II or Cd II , L=Morph, DMP or tmorph and X=DCA or TCA and n=O except in case of [Cd (Morph) 2 (TCA) 2 ] where n=1 have been synthesised. Some intermediate complexes have been isolated by temperature arrest technique (pyrolysis) and characterised. Configurational and conformational changes have been studied by elemental analyses, IR and electronic spectra, magnetic moment data (in the case of Ni(II) and Cu(II) complexes) and thermal analysis. E a * , ΔH, and ΔS for the decomposition reaction of these complexes are evaluated and the stability of the complexes with respect to activation energy has also been compared. The linear correlation has been found between E a * and ΔS for the decomposition of the complexes. (author)

  2. A study of the human immune response to Lolium perenne (rye) pollen and its components, Lol p I and Lol p II (rye I and rye II). I. Prevalence of reactivity to the allergens and correlations among skin test, IgE antibody, and IgG antibody data.

    Science.gov (United States)

    Freidhoff, L R; Ehrlich-Kautzky, E; Grant, J H; Meyers, D A; Marsh, D G

    1986-12-01

    In a stratified random sample of 320 white adults, the prevalence of puncture skin test positivity (ST +) to Lolium perenne (rye grass)-pollen extract (LPE) was 16%. Fifteen percent of all subjects (or 84% of subjects classified LPE IgE antibody positive [Ab +]) was classified IgE Ab + to highly purified Lol p I (Rye I), and 4% of all subjects (or 26% of subjects classified LPE IgE Ab +) was classified IgE Ab + to highly purified Lol p II (Rye II). These data and similar results obtained in an allergy-enriched group of 361 subjects are consistent with previous studies that Lol I is a major allergen and Lol II is a minor allergen of LPE. Whether we studied LPE, Lol I, or Lol II, responder subjects were younger than nonresponder subjects and more male than female subjects were responders. We then investigated the quantitative interrelationships among ST, IgE, and IgG Ab responsiveness to LPE, Lol I, and Lol II in the allergy-enriched group. For each allergen, log-log correlations were strong and significant for ST versus IgE Ab and for IgE Ab versus IgG Ab. All subjects IgE Ab + to Lol I or Lol II were IgG Ab + to that allergen, supporting other evidence for a commonality in the genetic control influencing the production of IgE and IgG Abs to a given allergen. Log-log correlations among ST end points, IgE Ab levels, or IgG Ab levels were strong for LPE versus either Lol I or Lol II but weak between Lol I and Lol II, consistent with the reported lack of cross-reactivity between Lol I and Lol II. Despite these findings, almost all Lol II + subjects were Lol I + by ST (98%), IgE Ab (91%), and IgG Ab (83%), suggesting that the Ia-restricted immune recognition of both these molecules is at least in part under a common genetic control.

  3. Test of long scintillating counter prototypes for CDF-II

    International Nuclear Information System (INIS)

    Budagov, Yu.; Chirikov-Zorin, I.; Pukhov, O.; Incagli, M.; Leone, S.; Menzione, A.; Pauletta, G.; Tokar, S.

    2000-01-01

    New type long (up to 3 m) scintillating counter prototypes, developed for CDF-II, have been tested. The shift-spectrum fiber ribbons were used for light collection, and modern ultra compact photomultipliers R5600 were used for light detection. The efficiency for m.i.p. was excellent for all prototypes. The light yield from the far end of the counters was found to be more than 20 photoelectrons

  4. PIP-II Injector Test: Challenges and Status

    Energy Technology Data Exchange (ETDEWEB)

    Derwent, P. F. [Fermilab; Carneiro, J. P. [Fermilab; Edelen, J. [Fermilab; Lebedev, V. [Fermilab; Prost, L. [Fermilab; Saini, A. [Fermilab; Shemyakin, A. [Fermilab; Steimel, J. [Fermilab

    2016-10-04

    The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW-compatible, pulsed H- superconducting RF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test is under construction. It includes a 10mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) that feeds the first of 2 cryomodules increasing the beam energy to about 25 MeV, and a High Energy Beam Transport section (HEBT) that takes the beam to a dump. The ion source, LEBT, RFQ, and initial version of the MEBT have been built, installed, and commissioned. This report presents the overall status of the Injector Test warm front end, including results of the beam commissioning through the installed components, and progress with SRF cryomodules and other systems.

  5. Phase II Vault Testing of the Argonne RFID System

    International Nuclear Information System (INIS)

    Willoner, T.; Turlington, R.; Koenig, R.

    2012-01-01

    The U.S. Department of Energy (DOE) (Environmental Management (EM), Office of Packaging and Transportation (EM-45)) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, in 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step (Phase

  6. PHASE II VAULT TESTING OF THE ARGONNE RFID SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Willoner, T.; Turlington, R.; Koenig, R.

    2012-06-25

    The U.S. Department of Energy (DOE) (Environmental Management [EM], Office of Packaging and Transportation [EM-45]) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, in 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step

  7. Test of In-core Flux Detectors in KNK II

    International Nuclear Information System (INIS)

    Hoppe, P.; Mitzel, F.

    1979-10-01

    The development of in-core detectors for Liquid Metal Fast Breeder Reactors (LMFBRs) is still in an early stage, and little operation experience is available. Therefore self-powered neutron and gamma detectors and neutron sensitive ionization chambers -especially developed for LMFBRs- have been tested in the Fast Sodium Cooled Test Reactor KNK II. Seven flux detectors have been installed in the core of KNK II by means of a special test rig. Five of them failed already within the first week during operation in the reactor. Due to measurements of electrical resistances and capacities, sodium penetrating into the detectors or cables probably seems to be the cause. As tests prior to the installation in the core proved the tightness of all detectors, it is suspected that small cracks have developed in the detector casings or in the outer cable sheaths during their exposure to the hot coolant. Two ionization chambers did not show these faults. However, one of them failed because the saturation current plateau disappeared and the other one's sensitivity decreased by a factor of five during the test period. It is suspected that in both cases changes of the filling gas might be involved

  8. Synthesis and spectral studies of manganese(II), cobalt(II), nickel(II), copper(II), zinc(II), cadmium(II) and mercury(II) complexes of 4-oxo-4H-1-benzopyran-3-carboxaldehyde hydrazone derivatives

    International Nuclear Information System (INIS)

    Nawar, N.; Khattab, M.A.; Bekheit, M.M.; El-Kaddah, A.H.

    1996-01-01

    A few complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II) with 4-oxo-4H-1-benzopyran-3-(carboxaldehyde-4-chlorobenzylhydrazone) (BCBH) and 4-oxo-4H-1-benzopyran-3-(carboxaldehyde-4-methylbenzylhydrazone) (BMBH) have been synthesised and characterized by elemental analysis, molar conductivities, magnetic measurements and infrared (IR) and visible spectral studies. The IR spectra show that BCBH and BMBH behave as bidentate ligands either in the keto or enol form. (author). 24 refs., 2 tabs

  9. Experimental Breeder Reactor II (EBR-II) Fuel-Performance Test Facility (FPTF)

    International Nuclear Information System (INIS)

    Pardini, J.A.; Brubaker, R.C.; Veith, D.J.; Giorgis, G.C.; Walker, D.E.; Seim, O.S.

    1982-01-01

    The Fuel-Performance Test Facility (FPTF) is the latest in a series of special EBR-II instrumented in-core test facilities. A flow control valve in the facility is programmed to vary the coolant flow, and thus the temperature, in an experimental-irradiation subassembly beneath it and coupled to it. In this way, thermal transients can be simulated in that subassembly without changing the temperatures in surrounding subassemblies. The FPTF also monitors sodium flow and temperature, and detects delayed neutrons in the sodium effluent from the experimental-irradiation subassembly beneath it. This facility also has an acoustical detector (high-temperature microphone) for detecting sodium boiling

  10. Test of In-core Flux Detectors in KNK II

    CERN Document Server

    Hoppe, P

    1979-01-01

    The development of in-core detectors for Liquid Metal Fast Breeder Reactors (LMFBRs) is still in an early stage, and little operation experience is available. Therefore self-powered neutron and gamma detectors and neutron sensitive ionization chambers -especially developed for LMFBRs- have been tested in the Fast Sodium Cooled Test Reactor KNK II. Seven flux detectors have been installed in the core of KNK II by means of a special test rig. Five of them failed already within the first week during operation in the reactor. Due to measurements of electrical resistances and capacities, sodium penetrating into the detectors or cables probably seems to be the cause. As tests prior to the installation in the core proved the tightness of all detectors, it is suspected that small cracks have developed in the detector casings or in the outer cable sheaths during their exposure to the hot coolant. Two ionization chambers did not show these faults. However, one of them failed because the saturation current plateau disap...

  11. Recent validation tests of the Edelweiss II detector holders

    International Nuclear Information System (INIS)

    Schwamm, F.; Chapellier, M.; Herve, S.; Karolak, M.; Navick, X.-F.

    2006-01-01

    A very good understanding of noise sources is highly important for the sensitivity of a dark matter search experiment. One of these noise contributions in the Edelweiss experiment could be the microphonics and temperature variations caused by vibrations of the cryostat. Recent studies complement an earlier work in describing the effect of the Edelweiss II detector holders on the amplitude of the vibrations seen by the detector. The results of these studies will be presented in this article

  12. The major results of the PISC II Round Robin test

    International Nuclear Information System (INIS)

    Crutzen, S.

    1987-01-01

    The objectives of the PISC-II programme were: - To evaluate the effectiveness of NDT techniques either in use or being developed for the inspection of reactor pressure vessel components, with regard mainly to detecting and charaterising service-induced flaws. - To identify techniques for acceptance tests, pre-service inspection (PSI) and in-service inspection (ISI) which could be generally accepted, and - to bring the conclusions of the programme to the attention of the Code, Standard and Regulatory Bodies concerned with ISI. (orig./HP)

  13. First Test of a Radionuclide Trap at KNK II

    International Nuclear Information System (INIS)

    Stamm, H.-H.; Hanke, H.-D.; Clauss, H.

    1984-03-01

    The first test of an experimental radionuclide trap was performed at KNK II. The aim was to remove some Zn-65 and Mn-54 from the primary sodium. The 2.3 l trap was filled with stainless steel and nickel pallrings of different sizes and was operated for 100 hours at 312 ''0C and a flow rate of 1.6 m''3 Na/h. On the Ni samples 110 times the amount of Mn-54 and 440 times the amount of Zn-65 have been sorbed compared to stainless steel pallrings of the same size. The activity sorbed was proportional to the surface area

  14. Alternate Reductant Cold Cap Evaluation Furnace Phase II Testing

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, F. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Stone, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Miller, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-09-03

    Savannah River Remediation (SRR) conducted a Systems Engineering Evaluation (SEE) to determine the optimum alternate reductant flowsheet for the Defense Waste Processing Facility (DWPF). Specifically, two proposed flowsheets (nitric–formic–glycolic and nitric–formic–sugar) were evaluated based upon results from preliminary testing. Comparison of the two flowsheets among evaluation criteria indicated a preference towards the nitric–formic–glycolic flowsheet. Further research and development of this flowsheet eliminated the formic acid, and as a result, the nitric–glycolic flowsheet was recommended for further testing. Based on the development of a roadmap for the nitric–glycolic acid flowsheet, Waste Solidification Engineering (WS-E) issued a Technical Task Request (TTR) to address flammability issues that may impact the implementation of this flowsheet. Melter testing was requested in order to define the DWPF flammability envelope for the nitric-glycolic acid flowsheet. The Savannah River National Laboratory (SRNL) Cold Cap Evaluation Furnace (CEF), a 1/12th scale DWPF melter, was selected by the SRR Alternate Reductant project team as the melter platform for this testing. The overall scope was divided into the following sub-tasks as discussed in the Task Technical and Quality Assurance Plan (TTQAP): Phase I - A nitric–formic acid flowsheet melter test (unbubbled) to baseline the CEF cold cap and vapor space data to the benchmark melter flammability models; Phase II - A nitric–glycolic acid flowsheet melter test (unbubbled and bubbled) to: Define new cold cap reactions and global kinetic parameters in support of the melter flammability model development; Quantify off-gas surging potential of the feed; Characterize off-gas condensate for complete organic and inorganic carbon species. After charging the CEF with cullet from Phase I CEF testing, the melter was slurry-fed with glycolic flowsheet based SB6-Frit 418 melter feed at 36% waste

  15. Centrifuge workers study. Phase II, completion report

    Energy Technology Data Exchange (ETDEWEB)

    Wooten, H.D.

    1994-09-01

    Phase II of the Centrifuge Workers Study was a follow-up to the Phase I efforts. The Phase I results had indicated a higher risk than expected among centrifuge workers for developing bladder cancer when compared with the risk in the general population for developing this same type of cancer. However, no specific agent could be identified as the causative agent for these bladder cancers. As the Phase II Report states, Phase I had been limited to workers who had the greatest potential for exposure to substances used in the centrifuge process. Phase II was designed to expand the survey to evaluate the health of all employees who had ever worked in Centrifuge Program Departments 1330-1339 but who had not been interviewed in Phase I. Employees in analytical laboratories and maintenance departments who provided support services for the Centrifuge Program were also included in Phase II. In December 1989, the Oak Ridge Associated Universities (ORAU), now known as Oak Ridge Institute for Science and Education (ORISE), was contracted to conduct a follow-up study (Phase II). Phase H of the Centrifuge Workers Study expanded the survey to include all former centrifuge workers who were not included in Phase I. ORISE was chosen because they had performed the Phase I tasks and summarized the corresponding survey data therefrom.

  16. Centrifuge workers study. Phase II, completion report

    International Nuclear Information System (INIS)

    Wooten, H.D.

    1994-09-01

    Phase II of the Centrifuge Workers Study was a follow-up to the Phase I efforts. The Phase I results had indicated a higher risk than expected among centrifuge workers for developing bladder cancer when compared with the risk in the general population for developing this same type of cancer. However, no specific agent could be identified as the causative agent for these bladder cancers. As the Phase II Report states, Phase I had been limited to workers who had the greatest potential for exposure to substances used in the centrifuge process. Phase II was designed to expand the survey to evaluate the health of all employees who had ever worked in Centrifuge Program Departments 1330-1339 but who had not been interviewed in Phase I. Employees in analytical laboratories and maintenance departments who provided support services for the Centrifuge Program were also included in Phase II. In December 1989, the Oak Ridge Associated Universities (ORAU), now known as Oak Ridge Institute for Science and Education (ORISE), was contracted to conduct a follow-up study (Phase II). Phase H of the Centrifuge Workers Study expanded the survey to include all former centrifuge workers who were not included in Phase I. ORISE was chosen because they had performed the Phase I tasks and summarized the corresponding survey data therefrom

  17. Comparison of vibration test results for Atucha II NPP and large scale concrete block models

    International Nuclear Information System (INIS)

    Iizuka, S.; Konno, T.; Prato, C.A.

    2001-01-01

    In order to study the soil structure interaction of reactor building that could be constructed on a Quaternary soil, a comparison study of the soil structure interaction springs was performed between full scale vibration test results of Atucha II NPP and vibration test results of large scale concrete block models constructed on Quaternary soil. This comparison study provides a case data of soil structure interaction springs on Quaternary soil with different foundation size and stiffness. (author)

  18. Early Tests of Piagetian Theory Through World War II.

    Science.gov (United States)

    Beins, Bernard C

    2016-01-01

    Psychologists recognized the importance of Jean Piaget's theory from its inception. Within a year of the appearance of his first book translated into English, The Language and Thought of the Child (J. Piaget, 1926) , it had been reviewed and welcomed; shortly thereafter, psychologists began testing the tenets of the theory empirically. The author traces the empirical testing of his theory in the 2 decades following publication of his initial book. A review of the published literature through the World War II era reveals that the research resulted in consistent failure to support the theoretical mechanisms that Piaget proposed. Nonetheless, the theory ultimately gained traction to become the bedrock of developmental psychology. Reasons for its persistence may include a possible lack of awareness by psychologists about the lack of empirical support, its breadth and complexity, and a lack of a viable alternate theory. As a result, the theory still exerts influence in psychology even though its dominance has diminished.

  19. Prototype system tests of the Belle II PXD DAQ system

    Energy Technology Data Exchange (ETDEWEB)

    Fleischer, Soeren; Gessler, Thomas; Kuehn, Wolfgang; Lange, Jens Soeren; Muenchow, David; Spruck, Bjoern [II. Physikalisches Institut, Justus-Liebig-Universitaet Giessen (Germany); Liu, Zhen' An; Xu, Hao; Zhao, Jingzhou [Institute of High Energy Physics, Chinese Academy of Sciences (China); Collaboration: II PXD Collaboration

    2012-07-01

    The data acquisition system for the Belle II DEPFET Pixel Vertex Detector (PXD) is designed to cope with a high input data rate of up to 21.6 GB/s. The main hardware component will be AdvancedTCA-based Compute Nodes (CN) equipped with Xilinx Virtex-5 FX70T FPGAs. The design for the third Compute Node generation was completed recently. The xTCA-compliant system features a carrier board and 4 AMC daughter boards. First test results of a prototype board will be presented, including tests of (a) The high-speed optical links used for data input, (b) The two 2 GB DDR2-chips on the board and (c) Output of data via ethernet, using UDP and TCP/IP with both hardware and software protocol stacks.

  20. BWR Full Integral Simulation Test (FIST) Phase II test results and TRAC-BWR model qualification

    International Nuclear Information System (INIS)

    Sutherland, W.A.; Alamgir, M.; Findlay, J.A.; Hwang, W.S.

    1985-10-01

    Eight matrix tests were conducted in the FIST Phase I. These tests investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. There are nine tests in Phase II of the FIST program. They include the following LOCA tests: BWR/6 LPCI line break, BWR/6 intermediate size recirculation break, and a BWR/4 large break. Steady state natural circulation tests with feedwater makeup performed at high and low pressure, and at high pressure with HPCS makeup, are included. Simulation of a transient without rod insertion, and with controlled depressurization, was performed. Also included is a simulation of the Peach Bottom turbine trip test. The final two tests simulated a failure to maintain water level during a postulated accident. A FIST program objective is to assess the TRAC code by comparisons with test data. Two post-test predictions made with TRACB04 are compared with Phase II test data in this report. These are for the BWR/6 LPCI line break LOCA, and the Peach Bottom turbine trip test simulation

  1. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty Cycles for Laboratory Testing II.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld engines with the following steady-state duty cycle: G3 mode No. Engine speed a Torque(percent) b Weighting...

  2. Pipe Overpack Container Fire Testing: Phase I & II

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa, Victor G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ammerman, Douglas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lopez, Carlos [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gill, Walter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a new series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016, and described herein, were done in two phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. This report will describe the various tests conducted in phase I and II, present preliminary results from these tests, and discuss implications for the POCs.

  3. Full scale dynamic tests of Atucha II NPP

    International Nuclear Information System (INIS)

    Konno, T.; Alvarez, L.M.; Ceballos, M.A.; Prato, C.A.; Uchiyama, S.; Godoy, A.R.

    1995-01-01

    This paper summarizes the main results of a series of dynamic tests of the reactor building of Atucha II NPP performed to determine the dynamic properties of its massive structure deeply embedded in Quaternary soil deposits. Tests were performed under two different types of loading conditions: Steady state harmonic loads imposed by mechanical exciters and impulsive loads induced by dropping a weight on the ground surface in the vicinity. Natural frequencies and mode shapes were identified and the associated modal damping ratios were experimentally determined. Numerical analyses of the reactor building-foundation system by two different F.E. models were performed. One of them, based on an axisymmetric representation of the soil-structure system, was used to simulate the steady state vibration tests and to calculate the dynamic stiffness of the foundation slab and soil layers for comparison with those experimentally obtained. The other, a 3-D F.E. model of the superstructure, was used to assess the natural frequencies and mode shapes obtained from the tests, representing dynamic stiffness of the foundation with stiffness coefficients derived both from the tests and from the axisymmetric F.E. model. Good agreement of the natural frequencies given by two types of tests was generally found, with the largest difference between them in the fundamental frequency of the building. Estimates of modal damping derived from the tests showed significant differences depending on the technique used to calculate them. For the fundamental mode damping was found to be 23-42 %, gradually decreasing with frequency to 2-4 % for around 10 Hz. (author)

  4. Full scale dynamic tests of Atucha II NPP

    International Nuclear Information System (INIS)

    Prato, C.A.; Ceballos, M.A.; Konno, T.; Uchiyama, S.; Alvarez, L.M.; Godoy, A.R.

    1998-01-01

    This paper summarizes the main results of a series of dynamic tests of the reactor building of Atucha II NPP performed to determine the dynamic properties of its massive structure deeply embedded in quaternary soil deposits. Tests were performed under two different types of loading conditions: steady state harmonic loads imposed by mechanical exciters and impulsive loads induced by dropping a weight on the ground surface in the vicinity. Natural frequencies and mode shapes were identified and the associated modal damping ratios were experimentally determined. Numerical analyses of the reactor building-foundation system by two different F.E. models were performed. One of them, based on an axisymmetric representation of the soil-structure system, was used to simulate the steady state vibration tests and to calculate the dynamic stiffness of the foundation slab and soil layers for comparison with those experimentally obtained. The other, a 3-D F.E. model of the superstructure, was used to assess the natural frequencies and mode shapes obtained from the tests, representing dynamic stiffness of the foundation with stiffness coefficients derived both from the tests and from the axisymmetric F.E. model. Good agreement of the natural frequencies given by two types of tests were generally found, with the largest difference between them in the fundamental frequency of the building. Estimates of modal damping derived from the tests showed significant differences depending on the technique used to calculate them. For the fundamental mode, damping was found to be 23-42%, gradually decreasing with frequency to 2-4% for ∝10 Hz. (orig.)

  5. Pipe Overpack Container Fire Testing: Phase I II & III.

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa, Victor G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ammerman, Douglas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lopez, Carlos [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gill, Walter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016 were done in three phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. The goal of the third phase was to see if surrogate aerosol gets released from the PC when the drum lid is off. This report will describe the various tests conducted in phase I, II, and III, present preliminary results from these tests, and discuss implications for the POCs.

  6. Observational tests for H II region models - A 'champagne party'

    Energy Technology Data Exchange (ETDEWEB)

    Alloin, D; Tenorio-Tagle, G

    1979-09-01

    Observations of several neighboring H II regions associated with a molecular cloud were performed in order to test the champagne model of H II region-molecular cloud interaction leading to the supersonic expansion of molecular cloud gas. Nine different positions in the Gum 61 nebula were observed using an image dissector scanner attached to a 3.6-m telescope, and it is found that the area corresponds to a low excitation, high density nebula, with electron densities ranging between 1400 and 2800/cu cm and larger along the boundary of the ionized gas. An observed increase in pressure and density located in an interior region of the nebula is interpreted in terms of an area between two rarefaction waves generated together with a strong isothermal shock, responsible for the champagne-like streaming, by a pressure discontinuity between the ionized molecular cloud in which star formation takes place and the intercloud gas. It is noted that a velocity field determination would provide the key in understanding the evolution of such a region.

  7. A Study of General Education Astronomy Students' Understandings of Cosmology. Part II. Evaluating Four Conceptual Cosmology Surveys: A Classical Test Theory Approach

    Science.gov (United States)

    Wallace, Colin S.; Prather, Edward E.; Duncan, Douglas K.

    2011-01-01

    This is the second of five papers detailing our national study of general education astronomy students' conceptual and reasoning difficulties with cosmology. This article begins our quantitative investigation of the data. We describe how we scored students' responses to four conceptual cosmology surveys, and we present evidence for the inter-rater…

  8. Development of an in vitro skin sensitization test using human cell lines; human Cell Line Activation Test (h-CLAT). II. An inter-laboratory study of the h-CLAT.

    Science.gov (United States)

    Sakaguchi, H; Ashikaga, T; Miyazawa, M; Yoshida, Y; Ito, Y; Yoneyama, K; Hirota, M; Itagaki, H; Toyoda, H; Suzuki, H

    2006-08-01

    Recent regulatory changes have placed a major emphasis on in vitro safety testing and alternative models. In regard to skin sensitization tests, dendritic cells (DCs) derived from human peripheral blood have been considered in the development of new in vitro alternatives. Human cell lines have been also reported recently. In our previous study, we suggested that measuring CD86 and/or CD54 expression on THP-1 cells (human monocytic leukemia cell line) could be used as an in vitro skin sensitization method. An inter-laboratory study among two laboratories was undertaken in Japan in order to further develop an in vitro skin sensitization model. In the present study, we used two human cell lines: THP-1 and U-937 (human histiocytic lymphoma cell line). First we optimized our test protocol (refer to the related paper entitled "optimization of the h-CLAT protocol" within this journal) and then we did an inter-laboratory validation with nine chemicals using the optimized protocol. We measured the expression of CD86 and CD54 on the above cells using flow cytometry after a 24h and 48h exposure to six known allergens (e.g., DNCB, pPD, NiSO(4)) and three non-allergens (e.g., SLS, tween 80). For the sample test concentration, four doses (0.1x, 0.5x, 1x, and 2x of the 50% inhibitory concentration (IC(50))) were evaluated. IC(50) was calculated using MTT assay. We found that allergens/non-allergens were better predicted using THP-1 cells compared to U-937 cells following a 24 h and a 48 h exposure. We also found that the 24h treatment time tended to have a better accuracy than the 48 h treatment time for THP-1 cells. Expression of CD86 and CD54 were good predictive markers for THP-1 cells, but for U-937 cells, expression of CD86 was a better predictor than CD54, at the 24h and the 48 h treatment time. The accuracy also improved when both markers (CD86 and CD54) were used as compared with a single marker for THP-1 cells. Both laboratories gave a good prediction of allergen

  9. Evaluation of LLTR Series II tests A-1A and A-1B test results

    International Nuclear Information System (INIS)

    Shoopak, B.F.; Amos, J.C.; Norvell, T.J.

    1980-03-01

    The standard methodology, with minor modifications provides conservative yet realistic predictions of leaksite and other sodium system pressures in the LLTR Series II vessel and piping. The good agreement between predicted and measured pressures indicates that the TRANSWRAP/RELAP modeling developed from the Series I tests is applicable to larger scale units prototypical of the Clinch River steam generator design. Calculated sodium system pressures are sensitive to several modeling parameters including rupture disc modeling, acoustic velocity in the test vessel, and flow rate from the rupture tube. The acoustic velocity which produced best agreement with leaksite pressures was calculated based on the shroud diameter and shroud wall thickness. The corresponding rupture tube discharge coefficient was that of the standard design methodology developed from Series I testing. As found in Series I testing, the Series II data suggests that the leading edge of the flow in the relief line is two phase for a single, doubled-ended guillotine tube rupture. The steam generator shroud acts as if it is relatively transparent to the transmission of radial pressures to the vessel wall. Slightly lower sodium system maximum pressures measured during Test A-1b compared to Test A-1a are attributed to premature failure (failure at a lower pressure) of the rupture disc in contact with the sodium for test A-1b. The delay in failure of the second disc in Test A-1b, which was successfully modeled with TRANSWRAP, is attributed to the limited energy in the nitrogen injection

  10. Study of physicochemical parameters for cadmium (II) and mercury (II) phytoremediation using the specie Eichhornia Crassipes (water hyacinth)

    International Nuclear Information System (INIS)

    Poma Llantoy, Victor R.; Valderrama Negron, Ana C.

    2014-01-01

    In this work, the studies were performed to measure the sorption capacity of metal ions Cd (II) and Hg (II) using the specie Eichhornia crassipes (water hyacinth). This study includes assays where the nutrient concentration, the pH and the metal ion concentration were optimized. These tests were carried out at room temperature and with aqueous solutions of Cd (II), Hg (II), in which the samples of Eichhornia crassipes were placed. To confirm the removal of these metals, the waste solutions after the treatment with the Water Hyacinth species were treated using the method APHA 3030-e. However, Eichhornia crassipes samples were treated using the EPA 200.3 method. The concentration of Cd (II) was determined by an ICP-OES spectrometer and Hg (II), by an atomic absorption spectrophotometer. The results showed: Optimal dosage 1 mL of A and 0,5 mL of B, optimum pH 5, optimum concentration of Cd (II) and Hg (II) 5 mg/L for each ion. With these parameters, it was started the removal of 5 mg/L of the metal ions contained in 1 L of solution. Being the percentages of sorption 16,56% for Cd (II) and 15,6% for Hg (II) after a period of 7 days. (author)

  11. Liquid metal blanket module testing and design for ITER/TIBER II

    International Nuclear Information System (INIS)

    Mattas, R.F.; Cha, Y.; Finn, P.A.; Majumdar, S.; Picologlou, B.; Stevens, H.; Turner, L.

    1988-05-01

    A major goal for ITER is the testing of nuclear components to demonstrate the integrated performance of the most attractive concepts that can lead to a commercial fusion reactor. As part of the ITER/TIBER II study, the test program and design of test models were examined for a number of blanket concepts. The work at Argonne National Laboratory focused on self-cooled liquid metal blankets. A test program for liquid metal blankets was developed based upon the ITER/TIBER II operating schedule and the specific data needs to resolve the key issues for liquid metals. Testing can begin early in reactor operation with liquid metal MHD tests to confirm predictive capability. Combined heat transfer/MHD tests can be performed during initial plasma operation. After acceptable heat transfer performance is verified, tests to determine the integrated high temperature performance in a neutron environment can begin. During the high availability phase operation, long term performance and reliability tests will be performed. It is envisioned that a companion test program will be conducted outside ITER to determine behavior under severe accident conditions and upper performance limits. A detailed design of a liquid metal test module and auxiliary equipment was also developed. The module followed the design of the TPSS blanket. Detailed analysis of the heat transfer and tritium systems were performed, and the overall layout of the systems was determined. In general, the blanket module appears to be capable of addressing most of the testing needs. 8 refs., 27 figs., 11 tabs

  12. Boundary scan test of Belle II pixel detector electronics

    Energy Technology Data Exchange (ETDEWEB)

    Leitl, Philipp [Max-Planck-Institut fuer Physik (Werner-Heisenberg-Institut), Foehringer Ring 6, 80805 Muenchen (Germany)

    2015-07-01

    For the upgrade of the Vertex Detector at the Belle II experiment, DEPFET sensors will be used. These sensors need Application-Specific Integrated Circuits (ASICs) for control, readout and data processing. Because of high demands for a low material budget in the sensitive area, there is only little space left for these ASICs. Using state-of-the-art technologies like Ball Grid Array (BGA) chips, which are flip-chip mounted, the requirement of 14 ASICs on each of the 40 half ladders can be fulfilled. However, this highly integrated on-sensor ASIC solution results in a lack of physical access to the electrical connections, which is a problem for traditional testing methods. To overcome these limitations, the JTAG standard IEEE 1149.1 is used to check if the circuit is in working condition. This method provides electrical access to the boundary scan cells implemented in the ASICs. Therefore it is possible to perform connectivity tests and verify if the production of the circuit was successful.

  13. Physics analysis of the TIBER-II engineering test reactor

    International Nuclear Information System (INIS)

    Uckan, N.A.; Houlberg, W.A.; Attenberger, S.E.; Dory, R.A.; Spong, D.A.; Tolliver, J.S.; Sheffield, J.

    1987-11-01

    Confinement capability, burn characteristics, heating and fueling requirements, and fast alpha particle effects are assessed for the TIBER-II engineering test reactor (ETR/ITER). Confinement predictions for a wide variety of empirical scaling laws show that ignition in TIBER-II (or similar ETR-like devices) is marginal at 10 MA, whereas the design goal to achieve noninductively driven, steady-state burn with Q > 5 can easily be attained. Operation at the higher plasma currents being discussed for ITER or the attainment of higher density limits and/or favorable H-mode scalings improves the ignition capability. Pellet penetration calculations indicate that density profile control with pellets may not be feasible even for pellet velocities up to about 50 km/s, however, density peaking could result from inward pinch effects, as frequently inferred from experiments. The fast alpha contribution to pressure is substantial (10 to 30%) at TIBER (or any ETR/ITER) burn temperatures (8 to 20 keV). A relatively low level of fast alpha radial diffusion or a modest level of thermal alpha buildup significantly influences the ignition and steady-state burn capability. The fast alpha population can also modify the background plasma ballooning mode stability boundaries, lowering the beta limit β/sub crit/ - in particular, operation at the high electron temperatures needed for efficient current drive can exacerbate this effect. The use of high-energy neutral beams offers the promise of two important improvements in projected performance: an effective method for noninductive current drive and a means for controlling the current density profile deep within the plasma, as required for stable operation at high beta levels. 14 refs., 10 figs., 1 tab

  14. Physics analysis of the TIBER-II engineering test reactor

    International Nuclear Information System (INIS)

    Uckan, N.A.; Houlberg, W.A.; Attenberger, S.E.; Dory, R.A.; Spong, D.A.; Tolliver, J.S.; Sheffield, J.

    1987-01-01

    Confinement capability, burn characteristics, heating and fueling requirements, and fast-alpha particle effects are assessed for the TIBER-II engineering test reactor (ETR/ITER). Confinement predictions for a wide variety of empirical scaling laws show that ignition on TIBER-II (or similar ETR-like devices) is marginal at 10 MA, whereas the design goal to achieve noninductively driven, steady-state burn with Q > 5 can easily be attained. Operation at the higher plasma currents being discussed for ITER or the attainment of higher density limits and/or favorable H-mode scalings improves the ignition capability. Pellet penetration calculations indicate that density profile control with pellets may not be feasible even for pellet velocities up to bout 50 km/s; however, density peaking could result from inward pinch effects, as frequently inferred from experiments. The fast alpha contribution to pressure is substantial (10-30%) at TIBER (or any ETR/ITER) burn temperatures (8-20 keV). A relatively low level of fast alpha radial diffusion or a modest level of thermal alpha buildup significantly influences the ignition and steady-state burn capability. The fast alpha population can also modify the background plasma ballooning mode stability boundaries, lowering the beta limit β/sub crit/ - in particular, operation at the high electron temperatures needed for efficient current drive can exacerbate this effect. The use of high-energy neutral beams offers the promise of two important improvements in projected performance: an effective method for noninductive current drive and a means for controlling the current density profile deep within the plasma, as required for stable operation at high beta levels

  15. Modular Electric Propulsion Test Bed Aircraft, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A hybrid electric aircraft simulation system and test bed is proposed to provide a dedicated development environment for the rigorous study and advancement of hybrid...

  16. Durability of lightweight concrete : Phase II : wetting and drying tests, Phase III : freezing and thawing tests.

    Science.gov (United States)

    1966-12-01

    This report describes a laboratory research program on the durability of lightweight concrete. Two phases of a three phase study are covered by this report, while the remaining phase is still under study. The two phases being reported are Phase II - ...

  17. Air-water tests in support of LLTR series II Test A-4

    International Nuclear Information System (INIS)

    Chen, K.

    1980-07-01

    A series of tests injecting air into a tank of stagnant water was conducted in June 1980 utilizing the GE Plenum Mixing Test Facility in San Jose, California. The test was concerned with investigating the behavior of air jets at a submerged orifice in water over a wide range of flow rates. The main objective was to improve the basic understanding of gas-liquid phenomena (e.g., leak dynamics, gas bubble agglomeration, etc.) in a simulated tube bundle through visualization. The experimental results from these air-water tests will be used as a guide to help select the leak size for LLTR Series II Test A-4 because air-water system is a good simulation of water-sodium mixture

  18. Evaluation of the KEMRI Hep-cell II test kit for detection of hepatitis B ...

    African Journals Online (AJOL)

    To evaluate the Hep-cell II test, blood samples were collected from blood donors and processed for detection of HBsAg using Hep-cell II based on the test principle and procedure outlined by the manufacturer. ELISA Axsym HBsAg test was used as golden standard. Of the 400 samples tested, 287 (71.8%) were positive by ...

  19. The Portuguese long version of the Copenhagen Psychosocial Questionnaire II (COPSOQ II) - a validation study.

    Science.gov (United States)

    Rosário, Susel; Azevedo, Luís F; Fonseca, João A; Nienhaus, Albert; Nübling, Matthias; da Costa, José Torres

    2017-01-01

    Psychosocial risks are now widely recognised as one of the biggest challenges for occupational safety and health (OSH) and a major public health concern. The aim of this paper is to investigate the Portuguese long version of the Copenhagen Psychosocial Questionnaire II (COPSOQ II), in order to analyse the psychometric properties of the instrument and to validate it. The Portuguese COPSOQ II was issued to a total of 745 Portuguese employees from both private and public organisations across several economic sectors at a baseline and then 2 weeks later. Methodological quality appraisal was based on COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) recommendations. An analysis of the psychometric properties of the long version of COPSOQ II (internal consistency, intraclass correlation coefficient, floor and ceiling effects, response rate, missing values, mean and standard deviation, exploratory factor analysis) was performed to determine the validity and reliability of the instrument. The COPSOQ II had a response rate of 60.6% (test) and a follow-up response rate of 59.5% (retest). In general, a Cronbach's alpha of the COPSOQ scales (test and retest) was above the conventional threshold of 0.70. The test-retest reliability estimated by the intraclass correlation coefficient (ICC) showed a higher reliability for most of the scales, above the conventional 0.7, except for eight scales. The proportion of the missing values was less than 1.3%, except for two scales. The average scores and standard deviations showed similar results to the original Danish study, except for eight scales. All of the scales had low floor and ceiling effects, with one exception . Overall, the exploratory factor analysis presented good results in 27 scales assuming a reflective measurement model. The hypothesized factor structure under a reflective model was not supported in 14 scales and for some but not all of these scales the explanation may be a formative

  20. Experiments with the HORUS-II test facility

    Energy Technology Data Exchange (ETDEWEB)

    Alt, S.; Lischke, W. [Univ. for Applied Sciences Zittau/Goerlitz, Zittau (Germany). Dept. of Nuclear Engineering

    1997-12-31

    Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as accident simulation tests for SBLOCA for VVER-conditions. The simulation conditions had been adjusted correspondingly to the parameters of a postulated SBLOCA`s fourth phase at the original plant. 4 refs.

  1. Tests of the gated mode for Belle II pixel detector

    Energy Technology Data Exchange (ETDEWEB)

    Prinker, Eduard [Max-Planck-Institute for Physics, Munich (Germany); Collaboration: Belle II-Collaboration

    2015-07-01

    DEPFET pixel detectors offer intrinsic amplification and very high signal to noise ratio. They form an integral building block for the vertex detector system of the Belle II experiment, which will start data taking in the year 2017 at the SuperKEKB Collider in Japan. A special Test board (Hybrid4) is used, which contains a small version of the DEPFET sensor with a read-out (DCD) and a steering chip (Switcher) attached, both controlled by a field-programmable gate array (FPGA) as the central interface to the computer. In order to keep the luminosity of the collider constant over time, the particle bunch currents have to be topped off by injecting additional bunches at a rate of 50 Hz. The particles in the daughter bunches produce a high rate of background (noisy bunches) for a short period of time, saturating the occupancy of the sensor. Operating the DEPFET sensor in a Gated Mode allows preserving the signals from collisions of normal bunches while protecting the pixels from background signals of the passing noisy bunches. An overview of the Gated Mode and first results is presented.

  2. Experiments with the HORUS-II test facility

    Energy Technology Data Exchange (ETDEWEB)

    Alt, S; Lischke, W [Univ. for Applied Sciences Zittau/Goerlitz, Zittau (Germany). Dept. of Nuclear Engineering

    1998-12-31

    Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as accident simulation tests for SBLOCA for VVER-conditions. The simulation conditions had been adjusted correspondingly to the parameters of a postulated SBLOCA`s fourth phase at the original plant. 4 refs.

  3. Experiments with the HORUS-II test facility

    International Nuclear Information System (INIS)

    Alt, S.; Lischke, W.

    1997-01-01

    Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as accident simulation tests for SBLOCA for VVER-conditions. The simulation conditions had been adjusted correspondingly to the parameters of a postulated SBLOCA's fourth phase at the original plant

  4. Safety test No. S-6, launch pad abort sequential test Phase II: solid propellant fire

    International Nuclear Information System (INIS)

    Snow, E.C.

    1975-08-01

    In preparation for the Lincoln Laboratory's LES 8/9 space mission, a series of tests was performed to evaluate the nuclear safety capability of the Multi-Hundred Watt (MHW) Radioisotope Thermoelectric Generator (RTG) to be used to supply power for the satellite. One such safety test is Test No. S-6, Launch Pad Abort Sequential Test. The objective of this test was to subject the RTG and its components to the sequential environments characteristic of a catastrophic launch pad accident to evaluate their capability to contain the 238 PuO 2 fuel. This sequence of environments was to have consisted of the blast overpressure and fragments, followed by the fireball, low velocity impact on the launch pad, and solid propellant fire. The blast overpressure and fragments were subsequently eliminated from this sequence. The procedures and results of Phase II of Test S-6, Solid Propellant Fire are presented. In this phase of the test, a simulant Fuel Sphere Assembly (FSA) and a mockup of a damaged Heat Source Assembly (HSA) were subjected to single proximity solid propellant fires of approximately 10-min duration. Steel was introduced into both tests to simulate the effects of launch pad debris and the solid rocket motor (SRM) casing that might be present in the fire zone. (TFD)

  5. Biosorption of Cd(II) and Zn(II) by nostoc commune: isotherm and kinetics studies

    Energy Technology Data Exchange (ETDEWEB)

    Morsy, Fatthy M. [Faculty of Science, Botany Department, Assiut University, Assiut (Egypt); Hassan, Sedky H.A. [Department of Biological Environment, Kangwon National University, Kangwon-do (Korea, Republic of); Koutb, Mostafa [Faculty of Science, Botany Department, Assiut University, Assiut (Egypt); Umm Al-Qura University, Faculty of Applied Science, Biology Department, Mecca (Saudi Arabia)

    2011-07-15

    In this study, Nostoc commune (cyanobacterium) was used as an inexpensive and efficient biosorbent for Cd(II) and Zn(II) removal from aqueous solutions. The effect of various physicochemical factors on Cd(II) and Zn(II) biosorption such as pH 2.0-7.0, initial metal concentration 0.0-300 mg/L and contact time 0-120 min were studied. Optimum pH for removal of Cd(II) and Zn(II) was 6.0, while the contact time was 30 min at room temperature. The nature of biosorbent and metal ion interaction was evaluated by infrared (IR) technique. IR analysis of bacterial biomass revealed the presence of amino, carboxyl, hydroxyl, and carbonyl groups, which are responsible for biosorption of Cd(II) and Zn (II). The maximum biosorption capacities for Cd(II) and Zn(II) biosorption by N. commune calculated from Langmuir biosorption isotherm were 126.32 and 115.41 mg/g, respectively. The biosorption isotherm for two biosorbents fitted well with Freundlich isotherm than Langmuir model with correlation coefficient (r{sup 2} < 0.99). The biosorption kinetic data were fitted well with the pseudo-second-order kinetic model. Thus, this study indicated that the N. commune is an efficient biosorbent for the removal of Cd(II) and Zn(II) from aqueous solutions. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Simulation of Particle Fluxes at the DESY-II Test Beam Facility

    International Nuclear Information System (INIS)

    Schuetz, Anne

    2015-05-01

    In the course of this Master's thesis ''Simulation of Particle Fluxes at the DESY-II Test Beam Facility'' the test beam generation for the DESY test beam line was studied in detail and simulated with the simulation software SLIC. SLIC uses the Geant4 toolkit for realistic Monte Carlo simulations of particles passing through detector material.After discussing the physics processes relevant for the test beam generation and the principles of the beam generation itself, the software used is introduced together with a description of the functionality of the Geant4 Monte Carlo simulation. The simulation of the test beam line follows the sequence of the test beam generation. Therefore, it starts with the simulation of the beam bunch of the synchrotron accelerator DESY-II, and proceeds step by step with the single test beam line components. An additional benefit of this thesis is the provision of particle flux and trajectory maps, which make fluxes directly visible by following the particle tracks through the simulated beam line. These maps allow us to see each of the test beam line components, because flux rates and directions change rapidly at these points. They will also guide the decision for placements of future test beam line components and measurement equipment.In the end, the beam energy and its spread, and the beam rate of the final test beam in the test beam area were studied in the simulation, so that the results can be compared to the measured beam parameters. The test beam simulation of this Master's thesis will serve as a key input for future test beam line improvements.

  7. A combination of ascorbic acid and α-tocopherol to test the effectiveness and safety in the fragile X syndrome: study protocol for a phase II, randomized, placebo-controlled trial.

    Science.gov (United States)

    de Diego-Otero, Yolanda; Calvo-Medina, Rocio; Quintero-Navarro, Carolina; Sánchez-Salido, Lourdes; García-Guirado, Francisco; del Arco-Herrera, Ignacio; Fernández-Carvajal, Isabel; Ferrando-Lucas, Teresa; Caballero-Andaluz, Rafaela; Pérez-Costillas, Lucia

    2014-09-03

    Fragile X syndrome (FXS) is an inherited neurodevelopmental condition characterised by behavioural, learning disabilities, physical and neurological symptoms. In addition, an important degree of comorbidity with autism is also present. Considered a rare disorder affecting both genders, it first becomes apparent during childhood with displays of language delay and behavioural symptoms.Main aim: To show whether the combination of 10 mg/kg/day of ascorbic acid (vitamin C) and 10 mg/kg/day of α-tocopherol (vitamin E) reduces FXS symptoms among male patients ages 6 to 18 years compared to placebo treatment, as measured on the standardized rating scales at baseline, and after 12 and 24 weeks of treatment.Secondary aims: To assess the safety of the treatment. To describe behavioural and cognitive changes revealed by the Developmental Behaviour Checklist Short Form (DBC-P24) and the Wechsler Intelligence Scale for Children-Revised. To describe metabolic changes revealed by blood analysis. To measure treatment impact at home and in an academic environment. A phase II randomized, double-blind pilot clinical trial. male children and adolescents diagnosed with FXS, in accordance with a standardized molecular biology test, who met all the inclusion criteria and none of the exclusion criteria. clinical data, blood analysis, Wechsler Intelligence Scale for Children-Revised, Conners parent and teacher rating scale scores and the DBC-P24 results will be obtained at the baseline (t0). Follow up examinations will take place at 12 weeks (t1) and 24 weeks (t2) of treatment. A limited number of clinical trials have been carried out on children with FXS, but more are necessary as current treatment possibilities are insufficient and often provoke side effects. In the present study, we sought to overcome possible methodological problems by conducting a phase II pilot study in order to calculate the relevant statistical parameters and determine the safety of the proposed treatment. The

  8. Synthesis, spectral, thermal and antimicrobial studies on cobalt(II), nickel(II), copper(II), zinc(II) and palladium(II) complexes containing thiosemicarbazone ligand

    Science.gov (United States)

    El-Sawaf, Ayman K.; El-Essawy, Farag; Nassar, Amal A.; El-Samanody, El-Sayed A.

    2018-04-01

    The coordination characteristic of new N4-morpholinyl isatin-3-thiosemicarbazone (HL) towards Co(II), Ni(II), Cu(II), Zn(II) and Pd(II) has been studies. The structures of the complexes were described by elemental analyses, molar conductivity, magnetic, thermal and spectral (IR, UV-Vis, 1H and 13C NMR and ESR) studies. On the basis of analytical and spectral studies the ligand behaves as monobasic tridentate ONS donor forming two five membered rings towards cobalt, copper and palladium and afforded complexes of the kind [M(L)X], (Mdbnd Co, Cu or Pd; Xdbnd Cl, Br or OAc). Whereas the ligand bound to NiCl2 as neutral tridentate ONS donor and with ZnCl2 as neutral bidentate NS donor. The newly synthesized thiosemicarbazone ligand and some of its complexes were examined for antimicrobial activity against 2 gram negative bacterial strains (Escherichia coli Pseudomonas and aeruginosa), 2 gram positive bacterial strains (Streptococcus pneumoniae and Staphylococcus aureus)} and two Pathogenic fungi (Aspergillus fumigatus and Candida albicans). All metal complexes possess higher antimicrobial activity comparing with the free thiosemicarbazone ligand. The high potent activities of the complexes may arise from the coordination and chelation, which tends to make metal complexes act as more controlling and potent antimicrobial agents, thus hindering the growing of the microorganisms. The antimicrobial results also show that copper bromide complex is better antimicrobial agent as compared to the Schiff base and its metal complexes.

  9. Regeneration Study Test Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Data (2 excel files) consist of the analytical test results on water sample collected from the two adsorption media tanks of the arsenic removal system during the...

  10. Full-Scale Mark II CRT program data report no. 10 (TEST 1203)

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Takeshita, Isao; Yamamoto, Nobuo; Namatame, Ken; Shiba, Masayoshi

    1981-03-01

    Recorded data for TEST 1203 conducted on the Full-Scale Mark II CRT (Containment Response Test) Facility are presented. The test 1203 is the third test run of a series of steam discharge pool swell test. It is one of the tests where break diameter was varied parametrically, i.e., TEST 1201 (200 mm), TEST 1202 (240 mm) and TEST 1203 (220 mm). The test was successfully conducted. A drywell initial pressurization rate of 188 kPa/s was obtained, which is approximately equal to what is postulated for a hypothetical DBA (Design Basis Accident) LOCA in the BWR Mark II containment. (author)

  11. Nuclear instrumentation system operating experience and nuclear instrument testing in the EBR-II

    International Nuclear Information System (INIS)

    Yingling, G.E.; Curran, R.N.

    1980-01-01

    In March of 1972 three wide range nuclear channels were purchased from Gulf Atomics Corporation and installed in EBR-II as a test. The three channels were operated as a test until April 1975 when they became a permanent part of the reactor shutdown system. Also described are the activities involved in evaluating and qualifying neutron detectors for LMFBR applications. Included are descriptions of the ANL Components Technology Division Test Program and the EBR-II Nuclear Instrument Test Facilities (NITF) used for the in-reactor testing and a summary of program test results from EBR-II

  12. HPV test by Hybrid Capture II for the diagnosis of HR-HPV persistent infection.

    Science.gov (United States)

    Serour, Y; Bendahmane, M; Abbou Baker, F; Medles, M; Moueddene, B; Kraiba, R

    2017-11-01

    Persistent high-risk HPV (HR-HPV) infection is associated with a greater risk of cervical cancer. Statistical data on the prevalence of HR-HPV infections in the Algerian population is lacking. We conducted a prospective study of 300 women aged between 25 and 50 years, screened for cervical cancer from 2012 to 2015 in Sidi Bel Abbès, a western region of Algeria. We aimed to assess the reliability of the repeated use of the HC II test (three longitudinal HPV tests 9 months apart from each other) in diagnosing the persistence of HR-HPV infection. The prevalence of HR-HPV infection was 7.33% and infected women were aged 37.9±3years. For 90.9% of HR-HPV-positive patients, the infection persisted for a mean of 18.5months [95% CI: 16.9-22.1months]. Among these patients, 55.55% developed CIN1 and 11.11% developed CIN2. The sensitivity of the HC II test was 81.74% [95% CI: 71.3-89.6] and its positive predictive value associated with abnormal cervical biopsy was 27.49% [95% CI: 16.0-33.33]. Repeating the HC II test is a good predictor for identifying women at high risk of cervical cancer. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. An Overview of the BIOMOVS II Study and its Findings

    International Nuclear Information System (INIS)

    1996-11-01

    BIOMOVS (BIOspheric MOdel Validation Study) was started under the auspices of the Swedish Radiation Protection Institute in 1985. Prior to the inception of the study, model testing had focussed on models of contaminant dispersion in the atmosphere, surface water and groundwater. In contrast, testing models of contaminant behaviour in soils, and in the terrestrial and aquatic food chains was receiving scant attention. BIOMOVS was therefore established as an international cooperative effort to redress this imbalance through the testing of models designed to quantify the transfer and uptake of radionuclides and other trace substances in the environment. When the first phase of BIOMOVS was completed in 1990, there still remained scope for further work. Clearly, in discussion of what should be done next, consideration had to be given to the output and conclusions of phase one of BIOMOVS, but also the objectives and programmes of other international projects and programmes, as well as the research and assessment interests of national bodies and organisations. Key interests were in particular areas of radioecology research, model validation and evaluation of uncertainties, and problems in performance assessment for solid waste repositories. Account was taken of the VAMP programme of the International Atomic Energy Agency (IAEA) and the interests of the Nuclear Energy Agency's Performance Assessment Advisory Group. Finally, it was decided that a second phase, BIOMOVS II, should be undertaken with funding from five organisations: The Atomic Energy Control Board, Canada; Atomic Energy of Canada Limited; Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, Spain; Empresa Nacional de Residuos Radiactivos SA, Spain; Swedish Radiation Protection Institute. By the completion of BIOMOVS II in October 1996 over 300 people from 31 countries and over 160 organisations had participated. This report provides an overview of the activities and achievements of BIOMOVS II

  14. Comparison of the Absorbable Polymer Sirolimus-Eluting Stent (MiStent) to the Durable Polymer Everolimus-Eluting Stent (Xience) (from the DESSOLVE I/II and ISAR-TEST-4 Studies).

    Science.gov (United States)

    Lansky, Alexandra J; Kastrati, Adnan; Edelman, Elazer R; Parise, Helen; Ng, Vivian G; Ormiston, John; Wijns, William; Byrne, Robert A

    2016-02-15

    We compared the outcomes of a novel, thin-strut, cobalt-chromium, absorbable, polymer sirolimus-eluting stent (APSES; MiStent) to the durable polymer cobalt-chromium everolimus-eluting stent (EES; Xience). A propensity-matched analysis was performed comparing data from the DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesions in the Native Coronary Arteries (DESSOLVE) I and II studies, evaluating the APSES to the EES arm of the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents-4 study. Target lesion failure (TLF) and its components were evaluated at 12 months and annually to 3 years; 805 patients (APSES = 153; EES = 652) were included with propensity matching in 204 patients (APSES = 102; EES = 102). APSES compared with EES had lower TLF at 1 year (3.0% vs 8.0%, p = 0.12) driven by a difference in target lesion revascularization (TLR; 1% vs 6%, p = 0.05), with no difference in target vessel myocardial infarction (p = 0.56) or stent thrombosis (p = 0.31). At 3 years, TLF (5.0% vs 12.5%, p = 0.07) and TLR (2.0% vs 8.4%, p = 0.04) remained lower with APSES. By landmark analysis, there was no significant difference in TLF between 1 and 3 years (p = 0.36). In conclusion, in a propensity-matched analysis, the APSES demonstrated reduced clinically indicated TLR rates at 1 and 3 years compared with the durable polymer EES, with minimal accrual of events between 1 and 3 years. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Radioiodination of melagenine-II with I-125 (preliminary study)

    International Nuclear Information System (INIS)

    Caso, R.; Ruiz, M.

    1996-01-01

    Radioiodination of Melagenine-II with I-125 farmacokinetic studies was made, using Chloramine-T method. Radiochemical purity and stability of the labelled product were determined by radiochromatography. The labelled Melagenine-II showed two radioactive fractions

  16. Full-Scale Mark II CRT program data report No. 11 (TEST 1204)

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Takeshita, Isao; Yamamoto, Nobuo; Namatame, Ken; Shiba, Masayoshi

    1981-03-01

    Recorded data for TEST 1204 conducted on the Full-Scale Mark II CRT (Containment Response Test) Facility are presented. The TEST 1204 is the fourth test run of a series of steam discharge pool swell tests. The test conditions are similar to those of the TEST 1203 except for lower initial pool temperature. The test was successful and the maximum level of pool surface was fairly lower than in the TEST 1203 due to the lower pool temperature. (author)

  17. Clinical studies of a purified timothy pollen extract: desensitization therapy with a purified timothy pollen preparation compared to a crude timothy pollen extract. II. Results of the tests in vitro and their relation to symptoms and tests in vivo.

    Science.gov (United States)

    Nordvall, S L; Berg, T; Johansson, S G; Lanner, A

    1982-01-01

    Perennial desensitization therapy was given during a period of 3.5 years to 40 children allergic to grass pollen allergens. 20 patients were treated with a crude and another 20 with a purified timothy pollen extract. 8 children served as untreated controls. The concentration of total and specific IgE in the treated groups covaried with those in the control group. Neither a suppression of the seasonal booster effect nor a suppression of IgE synthesis attributable to the treatment was found. The rise of timothy-specific "blocking' IgG antibodies was more pronounced in the group treated with the purified extract than in the group treated with the crude extract. A significant difference was found only after 3.5 years of treatment. The amplitude of rise of IgG antibodies correlated significantly with the effect of the treatment as judged by repeated conjunctival titration test. The results suggest that a good IgG response is an indication of successful therapy and that a better IgG response may be achieved with purified allergen extracts.

  18. Biological Tests for Boron Neutron Capture Therapy Research at the TRIGA Mark II Reactor in Pavia

    Energy Technology Data Exchange (ETDEWEB)

    Protti, N.; Ballarini, F.; Bortolussi, S.; De Bari, A.; Stella, S.; Altieri, S. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); Nuclear Physics National Institute (INFN), Pavia (Italy); Bruschi, P. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); Bakeine, J.G.; Cansolino, L.; Clerici, A.M. [Laboratory of Experimental Surgery, Department of Surgery, University of Pavia, Pavia (Italy)

    2011-07-01

    The thermal column of the TRIGA Mark II reactor of the Pavia University is used as an irradiation facility to perform biological tests and irradiations of living systems for Boron Neutron Capture Therapy (BNCT) research. The suitability of the facility has been ensured by studying the neutron flux and the photon background in the irradiation chamber inside the thermal column. This characterization has been realized both by flux and dose measurements as well as by Monte Carlo simulations. The routine irradiations concern in vitro cells cultures and different tumor animal models to test the efficacy of the BNCT treatment. Some results about these experiments will be described. (author)

  19. Blade System Design Study. Part II, final project report (GEC).

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Dayton A. (DNV Global Energy Concepts Inc., Seattle, WA)

    2009-05-01

    As part of the U.S. Department of Energy's Low Wind Speed Turbine program, Global Energy Concepts LLC (GEC)1 has studied alternative composite materials for wind turbine blades in the multi-megawatt size range. This work in one of the Blade System Design Studies (BSDS) funded through Sandia National Laboratories. The BSDS program was conducted in two phases. In the Part I BSDS, GEC assessed candidate innovations in composite materials, manufacturing processes, and structural configurations. GEC also made recommendations for testing composite coupons, details, assemblies, and blade substructures to be carried out in the Part II study (BSDS-II). The BSDS-II contract period began in May 2003, and testing was initiated in June 2004. The current report summarizes the results from the BSDS-II test program. Composite materials evaluated include carbon fiber in both pre-impregnated and vacuum-assisted resin transfer molding (VARTM) forms. Initial thin-coupon static testing included a wide range of parameters, including variation in manufacturer, fiber tow size, fabric architecture, and resin type. A smaller set of these materials and process types was also evaluated in thin-coupon fatigue testing, and in ply-drop and ply-transition panels. The majority of materials used epoxy resin, with vinyl ester (VE) resin also used for selected cases. Late in the project, testing of unidirectional fiberglass was added to provide an updated baseline against which to evaluate the carbon material performance. Numerous unidirectional carbon fabrics were considered for evaluation with VARTM infusion. All but one fabric style considered suffered either from poor infusibility or waviness of fibers combined with poor compaction. The exception was a triaxial carbon-fiberglass fabric produced by SAERTEX. This fabric became the primary choice for infused articles throughout the test program. The generally positive results obtained in this program for the SAERTEX material have led to its

  20. Experimental investigation of air relative humidity (RH) cycling tests on MEA/cell aging in PEMFC. Pt. II. Study of low RH cycling test with air RH at 62%/0%

    Energy Technology Data Exchange (ETDEWEB)

    Huang, B.T.; Chatillon, Y.; Bonnet, C.; Lapicque, F. [Laboratoire Reactions et Genie des Procedes, CNRS-Nancy University, Nancy (France); Leclerc, S. [Laboratoire d' Energetique et de Mecanique Theorique et Appliquee, CNRS-Nancy University, Vandoeuvre-les-Nancy (France); Hinaje, M.; Rael, S. [Groupe de Recherche en Electrotechnique et Electronique de Nancy, Nancy University, Vandoeuvre-les-Nancy (France)

    2012-06-15

    The effect of low relative humidity (RH) cycling (RH{sub C} 62%/0%) on the degradation mechanisms of a single proton exchange membrane fuel cell (5 x 5 cm{sup 2}) was investigated and compared to a cell operated at constant humidification (RH{sub C} = 62%). The overall cell performance loss was near 33 {mu}V h{sup -1}, which is greater than the voltage decay under constant RH condition near 3 {mu}V h{sup -1}. The electroactive surface was reduced but to an acceptable level. Impedance spectroscopy revealed that the ohmic and charge transfer resistances were reduced by the likely improved hydration of the ionomeric layer at the catalyst due to hydrogen crossover. This was so important that H{sub 2} starvation was finally responsible for the collapse of the cell after 650 h. Transmission electron microscopy showed occurrence of various phenomena, e.g., bubbles and pinholes formation in the membrane due to local overheat from hydrogen combustion at the cathode, and thickness reduction of catalytic layers. The water up take obtained by {sup 1}H NMR within the membrane electrode assembly (MEA) after low RH cycling reduced by 24% compared to a fresh MEA. Observations are also compared to those obtained at high RH cycling (RH{sub C} 62%/100%) presented in Part I of this study [1]. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Adsorption study of cadmium (II) and lead (II) on radish peels

    International Nuclear Information System (INIS)

    Anwar, J.; Shafique, U.; Salman, M.; Zaman, W.; Memoona, M.

    2009-01-01

    The removal efficiency of heavy metals like Cd(II) and Pb(II) from aqueous solutions by adsorption on Raphanus sativus (Radish peels) has been studied. The effects of time, pH, concentration of adsorbent and agitation speed on adsorption have been evaluated. It is found that radish peels powder has high removal efficiency for both the metals. Batch adsorption study has shown that Cd(II) and Pb(II) has been removed up to 88% and 86% respectively. Adsorption equilibriums for both metals have been described by the Langmuir isotherm. The maximum amount of heavy metals (Q ) adsorbed at max equilibrium were 7.5 and 1.23 mg/g for Cd(II) and Pb(II) respectively as evaluated by Langmuir isotherm. It is concluded that waste materials like radish peels can be used for removal of heavy metals from aqueous streams. (author)

  2. LCLS-II 1.3 GHz cryomodule design - lessons learned from testing at Fermilab

    Science.gov (United States)

    Kaluzny, J.; Hurd, J.; Orlov, Y.; He, Y.; Bossert, R.; Grimm, C.; Schappert, W.; Atassi, O. Al; Wang, R.; Arkan, T.; Theilacker, J.; Klebaner, A.; White, M.; Wu, G.; Makara, J.; Ginsburg, C.; Pei, L.; Holzbauer, J.; Hansen, B.; Stanek, R.; Peterson, T.; Harms, E.

    2017-12-01

    Fermilab’s 1.3 GHz prototype cryomodule for the Linac Coherent Light Source Upgrade (LCLS-II) has been tested at Fermilab’s Cryomodule Test Facility (CMTF). Aspects of the cryomodule design have been studied and tested. The cooldown circuit was used to quickly cool the cavities through the transition temperature, and a heater on the circuit was used to heat incoming helium for warmup. Due to the 0.5% slope of the cryomodule, the liquid level is not constant along the length of the cryomodule. This slope as well as the pressure profile caused liquid level management to be a challenge. The microphonics levels in the cryomodule were studied and efforts were made to reduce them throughout testing. Some of the design approaches and studies performed on these aspects will be presented. Fermilab is operated by Fermi Research Alliance, LLC under Contract No. De-AC02-07CH11359 with the United States Department of Energy. This work was supported, in part, by the LCLS-II Project.

  3. Study of new rubber to steel adhesive systems based on Co(II and Cu(II sulphides coats

    Directory of Open Access Journals (Sweden)

    Labaj Ivan

    2018-01-01

    Full Text Available The presented paper deals with the preparation of new rubber to steel adhesive systems using the steel surface treatment with deposition of adhesive coats based on Co(II and Cu(II sulphides. Efficiency of new prepared adhesive systems containing Co(II and Cu(II sulphides has been compared with the efficiency of double layer adhesive system commonly used in industry. The chemical composition of prepared adhesive systems was determined using the EDX analysis. Scanning Electron Microscopy (SEM was used for study of topography and microstructure of prepared rubber to steel adhesive systems (Co(II, Cu(II sulphide, double layer adhesive system. For determination of adhesion strength between rubber blends and metal pieces with various adhesive systems deposited on these pieces, the test according to ASTM D429 standard relating to Rubber to metal adhesion, method A was used. For all test samples, the same type of rubber blend and the same curing conditions have been used.

  4. Preparation of Schiff s base complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Cd(II) and their spectroscopic, magnetic, thermal, and antifungal studies

    International Nuclear Information System (INIS)

    Parekh, H.M.; Patel, M.N.

    2006-01-01

    The potassium salt of salicylidene-DL-alanine (KHL), bis(benzylidene)ethylenediamine (A 1 ), thiophene-o-carboxaldene-p-toluidine (A 2 ), and its metal complexes of the formula [(M II (L)(A)(H 2 O)] (M=Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Cd(II); A = A 1 or A 2 ) are prepared. They are characterized by elemental analysis, magnetic susceptibility measurements, thermogravimetric analysis, and infrared and electronic spectral studies. The electronic spectral and magnetic moment data suggest an octahedral geometry for the complexes. All of these complexes, metal nitrates, fungicides (bavistin and emcarb), and ligands are screened for their antifungal activity against Aspergillus niger, Fusarium oxysporum, and Aspergillus flavus using a plate poison technique. The complexes show higher activity than those of the free ligands, metal nitrate, and the control (DMSO) and moderate activity against bavistin and emcarb [ru

  5. Breached fuel pin contamination from Run Beyond Cladding Breach (RBCB) tests in EBR-II

    International Nuclear Information System (INIS)

    Colburn, R.P.; Strain, R.V.; Lambert, J.D.B.; Ukai, S.; Shibahara, I.

    1988-09-01

    Studies indicate there may be a large economic incentive to permit some continued reactor operation with breached fuel pin cladding. A major concern for this type of operation is the potential spread of contamination in the primary coolant system and its impact on plant maintenance. A study of the release and transport of contamination from naturally breached mixed oxide Liquid Metal Reactor (LMR) fuel pins was performed as part of the US Department of Energy/Power Reactor and Nuclear Fuel Development Corporation (DOE/PNC) Run Beyond Cladding Breach (RBCB) Program at EBR-II. The measurements were made using the Breached Fuel Test Facility (BFTF) at EBR-II with replaceable deposition samplers located approximately 1.5 meters from the breached fuel test assemblies. The effluent from the test assemblies containing the breached fuel pins was routed up through the samplers and past dedicated instrumentation in the BFTF before mixing with the main coolant flow stream. This paper discusses the first three contamination tests in this program. 2 refs., 5 figs., 2 tabs

  6. Production Facility Prototype Blower 1000 Hour Test Results II

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-08

    Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

  7. Cloud-Based Electronic Test Procedures, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Procedures are critical to experimental tests as they describe the specific steps necessary to efficiently and safely carry out a test in a repeatable fashion. The...

  8. Summary of results from velocity profile tests and wastage tests in support of LLTR series II test A-4

    International Nuclear Information System (INIS)

    Greene, D.A.

    1981-01-01

    The following conclusions were drawn from the experimental program conducted in support of LLTR (Large Leak Test Rig) Series II Test A-4: Fabrication technique for making precise slits was developed. Wastage boundary agrees with velocity profile boundary. Circumferential slit angles would have to be 120 0 to ensure adequate coverage of adjacent tubes. 120 0 circumferential slit weakens tubes such that maintaining desired slit dimensions for LLTI application is not considered practical. Use of intermittent slit geometry would be required. 120 0 slits, precisely machined and precisely aligned with target tubes, produced different penetration rates on adjacent tubes. Production of simultaneous failures in LLTI with 120 0 slit or simulated interrupted slit is not considered credible

  9. FRM-II: status of construction, licensing fuel tests

    International Nuclear Information System (INIS)

    Axmann, A.; Boening, K.; Nuding, M.; Didier, H.J.

    2001-01-01

    The research reactor FRM-II of the Technische Universitaet Muenchen is now ready for the nuclear start-up, but still waiting for the operational license. The high-flux neutron-source FRM-II (8 x 10 14 n/(s cm 2 ) is a unique tool for solid state physics and materials research by neutron scattering, positron annihilation experiments and activation analysis, as well as for fundamental physics, isotope production, silicone doping, cancer therapy by irradiation with fission neutrons and for tomography with fast and thermal neutrons. Reactor built in facilities as a hot source, a cold source, an uranium loaded converter plate producing an intense beam of fission neutrons, allow to expand the range of usable neutron energies far beyond the thermal spectrum. In addition, a source providing an intense beam of fission products is planned to be constructed by the Ludwig-Maximilians-Universitaet Muenchen and a source of ultra cold neutrons is planned by the Physics Department of the Technische Universitaet Muenchen. The reactor is already prepared for both of these facilities. (author)

  10. Heavy Section Steel Technology Program. Part II. Intermediate vessel testing

    International Nuclear Information System (INIS)

    Whitman, G.D.

    1975-01-01

    The testing of the intermediate pressure vessels is a major activity under the Heavy Section Steel Technology Program. A primary objective of these tests is to develop or verify methods of fracture prediction, through the testing of selected structures and materials, in order that a valid basis can be established for evaluating the serviceability and safety of light-water reactor pressure vessels. These vessel tests were planned with sufficiently specific objectives that substantial quantitative weight could be given to the results. Each set of testing conditions was chosen so as to provide specific data by which analytical methods of predicting flaw growth, and in some cases crack arrest, could be evaluated. Every practical effort was made to assure that results would be relevant to some aspect of real reactor pressure vessel performance through careful control of material properties, selection of test temperatures, and design of prepared flaws. 5 references

  11. Risk Factors Accompanied with Nephropathy in Patients with Type II Diabetes; Test of the Biopsychosocial Model

    Directory of Open Access Journals (Sweden)

    I. Rahimian Boogar

    2012-07-01

    Full Text Available Introduction & Objective: The study of biopsychosocial factors influencing nephropathy as a most serious complication of type II diabetes is important. This study aimed to investigate risk factors accompanied with nephropathy in patients with type II diabetes based on the biopsychosocial model. Materials & Methods: In a cross-sectional descriptive study, 295 patients with type II diabetes were selected by convenience sampling in Tehran Shariati hospital outpatient clinics. The data were collected by demographical information questionnaire along with disease characteristics and depression anxiety stress scales (dass, quality of life scale (who- qol- bref, diabetes self-management scale (dsms, and diabetes knowledge scale (dks, then analyzed by chi-square, independent t-test and logistic regression with pasw software. Results: Hypertension (OR=3.841 & P0.05.Conclusion: It is important to pay attention to hypertension, glycated hemoglobin, body mass index, diabetes self-management, depression, quality of life, and diabetes knowledge for therapeutic intervention programming and diabetes complications control protocols for diabetic patients.(Sci J Hamadan Univ Med Sci 2012;19(2:44-53

  12. Mechanical testing of hydraulic fluids II; Mechanische Pruefung von Hydraulikfluessigkeiten II

    Energy Technology Data Exchange (ETDEWEB)

    Kessler, M.; Feldmann, D.G.; Laukart, V.

    2001-09-01

    Since May 1996 the Institute for Mechanical Engineering Design 1 of Technical University of Hamburg-Harburg is working on the topic of ''Mechanical Testing of Hydraulic fluids''. The first project lasting 2 1/2 years was completed in 1999, the results are published as the DGMK report 514. Within these project a testing principle for the ''mechanical testing'' of hydraulic fluids has been derived, a prototype of a test rig was designed and set in operation at the authors' institute. This DGMK-report 514-1 describes the results of the second project, which investigates the operating behaviour of the test-rig more in detail. Several test-runs with a total number of 11 different hydraulic fluids show the dependence of the different lubricating behaviour of the tested fluids and their friction and wear behaviour during the tests in a reproducible way. The aim of the project was to derive a testing principle including the design of a suitable test-rig for the mechanical testing of hydraulic fluids. Based on the described results it can be stated that with the developed test it is possible to test the lubricity of hydraulic fluids reproducible and in correlation to field experiences within a relatively short time, so the target was reached. (orig.)

  13. Evaluation of LLTR series II test A-7 results

    International Nuclear Information System (INIS)

    Knittle, D.E.; Amos, J.C.; Yang, T.M.

    1981-09-01

    This report evaluates the test A-7 data and assesses the capability of the analytical methodology (as a result of Series I program) to predict the thermal/hydraulic phenomena associated with a large SWR event occurring after the sodium system pressure has increased to near the rupture disc burst pressure due to a smaller size leak event. Evaluation of intertest examination data to determine the extent of test article damage resulting from test A-7 is also included

  14. Thermal, spectral, magnetic and biological studies of thiosemicarbazones complexes with metal ions: Cu(II), Co(II), Ni(II), Fe(III), Zn(II), Mn(II) and UO2(VI)

    International Nuclear Information System (INIS)

    Mashaly, M.M.; Seleem, H.S.; El-Behairy, M.A.; Habib, H.A.

    2004-01-01

    Thiosemicarbazones ligands, isatin-3-thiosemicarbazone(HIT) and N-acetylisatin-3-thiosemicarbazone (HAIT), which have tridentate ONN coordinating sites were prepared. The complexes of both ligands with Cu(II), Co(II), Ni(II), Fe(III), Zn(II), Mn(II) and UO 2 (VI) ions were isolated. The ligands and their metal complexes were characterized by elemental analysis, IR, UV-Vis and mass spectra, also by conductance, magnetic moment and TG-DSC measurements. All the transition metal complexes have octahedral configurations, except Cu-complexes which have planar geometry and the UO 2 (VI) complexes which have coordination number 8 and may acquire the distorted dodecahedral geometry. Thermal studies explored the possibility of obtaining new complexes. Inversion from octahedral to square-planar configuration occurred upon heating the parent Ni-HIAT complex to form the corresponding pyrolytic product. The antifungal activity against the tested organisms showed that some metal complexes enhanced the activity with respect to the parent ligands. (author)

  15. Horns Rev II, 2D-Model Tests

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Brorsen, Michael

    This report present the results of 2D physical model tests carried out in the shallow wave flume at Dept. of Civil Engineering, Aalborg University (AAU), Denmark. The starting point for the present report is the previously carried out run-up tests described in Lykke Andersen & Frigaard, 2006. The......-shaped access platforms on piles. The Model tests include mainly regular waves and a few irregular wave tests. These tests have been conducted at Aalborg University from 9. November, 2006 to 17. November, 2006.......This report present the results of 2D physical model tests carried out in the shallow wave flume at Dept. of Civil Engineering, Aalborg University (AAU), Denmark. The starting point for the present report is the previously carried out run-up tests described in Lykke Andersen & Frigaard, 2006....... The objective of the tests was to investigate the impact pressures generated on a horizontal platform and a cone platform for selected sea states calibrated by Lykke Andersen & Frigaard, 2006. The measurements should be used for assessment of slamming coefficients for the design of horizontal and cone...

  16. 49 CFR 238.317 - Class II brake test.

    Science.gov (United States)

    2010-10-01

    ....315(a)(1); (3) When previously tested units (i.e., cars that received a Class I brake test within the... hours) are added to the train; (4) When cars or equipment are removed from the train; and (5) When an... locomotives that utilize an electric signal to communicate a service brake application and only a pneumatic...

  17. Evaluation report on SCTF Core-II test S2-08

    International Nuclear Information System (INIS)

    Ohnuki, Akira; Iwamura, Takamichi; Abe, Yutaka; Murao, Yoshio; Adachi, Hiromichi.

    1991-01-01

    The present report investigates the effects of the difference of the core inlet subcooling during reflood in a PWR-LOCA on the thermal-hydraulic behaviors including two-dimensional behaviors in the pressure vessel in the Slab Core Test Facility (SCTF) Core-II tests under gravity feed mode. The following test results are examined: Tests S2-02 (Reference test) and Test S2-08 (High subcooling test). The degree of the difference of the subcooling between the two tests was about 20 to 35 K in the LPCI period. The following conclusions were obtained from this study: (1) Higher the subcooling gave larger amount of water accumulation in the core and gave better core cooling. These tendencies were also recognized in comparisons under the same distance from the quench front. Since the same tendencies can be predicted in the analyses with REFLA code because of the lower steam generation rate below quench front in the high subcooling test, the differences in the tests are supposed to be caused by the same reason. (2) Higher the subcooling gave larger amount of water accumulation in upper plenum. The carry-over liquid mass into hot leg became smaller in the later period in the higher subcooling test. These differences for carry-over and de-entrainment characteristics can be explained by the differences of quench velocity and of steam mass flow rate generated in the core. (3) No significant influence of the different degree of the subcooling was observed on the two-dimensional thermal-hydraulic behaviors in the pressure vessel. Namely, radial differences of sectional void fraction, heat transfer coefficient and the pressure among bundles at the same elevation were almost the same amount for the two tests. Radial differences of liquid levels in the upper plenum was also almost the same amount for the two tests. (J.P.N.)

  18. Capturing Cultural Glossaries: Case-study II

    Directory of Open Access Journals (Sweden)

    Matete Madiba

    2011-10-01

    Full Text Available

    ABSTRACT: This case-study attempts to present a brief glossary of Northern Sotho medical terms. It is a follow-up of a similar case-study (Madiba, Mphahlele and Kganyago 2003, which was an attempt to capture and present Northern Sotho cooking terms. Case-study I consists of the names for utensils, ingredients and the processes involved in the preparation of cultural dishes. With both these case-studies, the intention has been to use the opportunities availing themselves for the pres-ervation and valorisation of Northern Sotho, including the extension of its corpora to support national dictionary-making processes. The case-study methodology has been very useful for the purposes of this project and the context within which it was undertaken. It aims to provide a model for the collection and presentation of authentic Northern Sotho terminology which otherwise would hardly have been accessible.

    Keywords: CULTURAL GLOSSARY, INDIGENOUS KNOWLEDGE SYSTEMS, CORPUS, OUTCOMES-BASED EDUCATION, ASSESSMENT CRITERIA, TRADITIONAL MEDICAL TERMS, COMMUNICATIVE APPROACH, STRUCTURAL APPROACH, METONYMY, HANDS-ON ACTIVITIES, TASK-BASED LEARNING

    *****

    OPSOMMING: Die totstandbrenging van kulturele woordversamelings: Ge-vallestudie II. Hierdie gevallestudie probeer om 'n beperkte woordelys van Noord-Sotho- mediese terme aan te bied. Dit is 'n voortsetting van 'n soortgelyke gevallestudie (Madiba, Mpha-hlele en Kganyago 2003 wat 'n poging was om Noord-Sothokookterme te versamel en aan te bied. Gevallestudie I bestaan uit die name van gereedskap, bestanddele, en die prosesse betrokke by die voorbereiding van kulturele geregte. Met altwee hierdie gevallestudies was die bedoeling om die geleenthede te gebruik wat hulleself aanbied vir die bewaring en bestendiging van Noord-Sotho, insluitende die uitbreiding van sy korpora om die nasionale woordeboeksamestellingsprosesse te ondersteun. Die gevallestudiemetodologie was baie nuttig vir die doeleindes van

  19. Synthesis and studies on Cu(II), Co(II), Ni(II) complexes of Knoevenagel β-diketone ligands

    Science.gov (United States)

    Sumathi, S.; Tharmaraj, P.; Sheela, C. D.; Anitha, C.

    2012-11-01

    Transition metal complexes of various acetylacetone based ligands of the type ML [where M = Cu(II), Ni(II), Co(II); L = 3-(aryl)-pentane-2,4-dione] have been synthesized. The structural features have been derived from their elemental analysis, magnetic susceptibility, molar conductance, IR, UV-Vis, 1H NMR, Mass and ESR spectral studies. Conductivity measurements reveal that all the complexes are non-electrolytic in nature. Spectroscopic and other analytical data of the complexes suggest octahedral geometry for other metal(II) complexes. The redox behavior of the copper(II) complexes have been studied by cyclic voltammetry. The free ligands and their metal complexes have been screened for their in vitro biological activities against the bacteria Pseudomonas aeruginosa, Escherichia coli and Staphylococcus aureus as well as the fungus Candida albicans by well diffusion method. The zone of inhibition value indicates that the most of the metal(II) complexes are found to possess increased activities compared to those of the free ligands. All synthesized compounds may serve as potential photoactive materials as indicated from their characteristic fluorescence properties. The second harmonic generation (SHG) efficiency of the ligands (L1-L3) was found to be considerable effect than that of urea and KDP (potassium dihydrogen phosphate).

  20. Full-Scale Mark II CRT program data report no. 12 (TEST 1205)

    International Nuclear Information System (INIS)

    Takeshita, Isao; Kukita, Yutaka; Yamamoto, Nubuo; Namatame, Ken; Shiba, Masayoshi

    1981-03-01

    Recorded data for TEST 1205 conducted on the Full-Scale Mark II CRT (Containment Response Test) Facility are presented. The TEST 1205 is the fifth test run of a series of steam discharge pool swell tests. The test conditions are similar to those of the TEST 1203 except that the vacuum breaker was locked close. The test was successful and the comparison of the TEST 1205 and the TEST 1203 results shows that the vacuum breaker may have some effects to reduce the wetwell airspace pressurization, and thus to reduce the upward force to diaphram floor during a pool swell. (author)

  1. Fused Reality for Enhanced Flight Test Capabilities, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In terms of relevancy to piloted evaluation, there remains no substitute for actual flight tests even when considering the fidelity and effectiveness of modern...

  2. Distributed Rocket Engine Testing Health Monitoring System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging the Phase I achievements of the Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) including its software toolsets and system building...

  3. Horns Rev II, 2D-Model Tests

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Frigaard, Peter

    This report present the results of 2D physical model tests carried out in the shallow wave flume at Dept. of Civil Engineering, Aalborg University (AAU). The objective of the tests was: To investigate the combined influence of the pile diameter to water depth ratio and the wave height to water...... depth ratio on wave run-up of piles. The measurements should be used to design access platforms on piles. The Model tests include: Calibration of regular and irregular sea states at the location of the pile (without structure in place). Measurement of wave run-up for the calibrated sea states...... on the front side of the pile (0 to 90 degrees). These tests have been conducted at Aalborg University from 9. October, 2006 to 8. November, 2006. Unless otherwise mentioned, all values given in this report are in model scale....

  4. Biosorption of cadmium (II) and lead (II) from aqueous solutions using mushrooms: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Vimala, R., E-mail: vimararagu@yahoo.co.in [School of Biotechnology, Chemical and Biomedical Engineering, VIT University, Vellore 632014, Tamil Nadu (India); Das, Nilanjana [School of Biotechnology, Chemical and Biomedical Engineering, VIT University, Vellore 632014, Tamil Nadu (India)

    2009-08-30

    Sorption capacity of oyster mushroom (Pleurotus platypus), button mushroom (Agaricus bisporus) and milky mushroom (Calocybe indica) were evaluated on biosorption of heavy metals, viz. cadmium (II) and lead (II) from aqueous solutions. The optimum sorption conditions were studied for each metal separately. The desired pH of the aqueous solution was found to be 6.0 for the removal of cadmium (II) and 5.0 for removal of lead (II) for all the mushrooms. The percent removal of both the metals was found to increase with the increase in biosorbent dosage and contact time. The fitness of the biosorption data for Langmuir and Freundlich adsorption models was investigated. It was found that biosorption of cadmium (II) and lead (II) ions onto the biomass of the three mushrooms were better suitable to Langmuir than Freundlich adsorption model. P. platypus showed the highest metal uptake potential for cadmium (q{sub max} 34.96 mg/g) whereas A. bisporus exhibited maximum potential for lead (q{sub max} 33.78 mg/g). Milky mushroom showed the lowest metal uptake capacity for both the metals. The present data confirms that mushrooms may be used as efficient biosorbent for the removal of cadmium (II) and lead (II) ions from aqueous solution.

  5. Theory testing using case studies

    DEFF Research Database (Denmark)

    Dissing Sørensen, Pernille; Løkke Nielsen, Ann-Kristina

    2006-01-01

    on the strengths of theory-testing case studies. We specify research paths associated with theory testing in case studies and present a coherent argument for the logic of theoretical development and refinement using case studies. We emphasize different uses of rival explanations and their implications for research...... design. Finally, we discuss the epistemological logic, i.e., the value to larger research programmes, of such studies and, following Lakatos, conclude that the value of theory-testing case studies lies beyond naïve falsification and in their contribution to developing research programmes in a progressive......Case studies may have different research goals. One such goal is the testing of small-scale and middle-range theories. Theory testing refers to the critical examination, observation, and evaluation of the 'why' and 'how' of a specified phenomenon in a particular setting. In this paper, we focus...

  6. Second Stage (S-II) Arrives at Marshall Space Flight Center For Testing

    Science.gov (United States)

    2004-01-01

    The business end of a Second Stage (S-II) slowly emerges from the shipping container as workers prepare to transport the Saturn V component to the testing facility at MSFC. The Second Stage (S-II) underwent vibration and engine firing tests. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  7. The Savannah River environmental technology field test platform: Phase II

    International Nuclear Information System (INIS)

    Rossabi, J.; Riha, B.D.; May, C.P.; Pemberton, B.E.; Jarosch, T.R.; Eddy-Dilek, C.A.; Looney, B.B.; Raymond, R.

    1995-01-01

    The principal goal in the development of new technologies for environmental monitoring and characterization is transferring them to organizations and individuals for use in site assessment and compliance monitoring. The DOE complex has devised several strategies to facilitate this transfer including joint research projects between private industries and government laboratories or universities (CRADAs), and streamlined licensing procedures. One strategy that has been under-utilized is a planned sequence gradually moving from laboratory development and field demonstration to long term evaluation and onsite use. Industrial partnership and commercial production can be initiated at any step based on the performance, market, user needs, and costs associated with the technology. The Savannah River Technology Center (SRTC) has been developing a program to rigorously field test promising environmental technologies that have not undergone EPA equivalency testing. The infrastructure and staff expertise developed as part of the activities of the Savannah River Integrated Demonstration Program (i.e., wells, available power, conventional baseline characterization and monitoring equipment, shelter structures) allows field testing of technologies without the difficulties of providing remote field support. By providing a well-characterized site and a well-developed infrastructure, technologies can be tested for long periods of time to determine their appropriate applications in environmental characterization and monitoring activities. Situation specific evaluations of the technology following stringent test plans can be made in comparison with simultaneous baseline methods and historical data. This program is designed to help expedite regulatory approval and technology transfer to manufacturers and the user community

  8. PISC II: Parametric studies. Monitoring of PISC-II parametric studies in ultrasonic NDT for PWR

    International Nuclear Information System (INIS)

    Toft, M.W.

    1989-09-01

    The CEGB NDT Applications Centre is partipating in the EEC-funded international Programme for the Inspection of Steel Components (PISC) on account of its relevance to the inspection of Sizewell B and future PWRs. This report describes an inspection monitoring exercise undertaken by NDTAC under partial funding from JRC Ispra, at the initiation of the PISC-III Ultrasonic Modelling Group. Experimental studies have been carried out under PISC-II to investigate ultrasonic defect response as a function of various parameters which characterise the inspection situation. Some of these parametric studies are potentially useful for the validation of theoretical models of ultrasonic inspection and are consequently relevant to the work of the PISC-III Modelling Group. The aim of the present exercise was to ensure that data obtained by the various contract organizations participating in the PISC-II Parametric Studies was of high quality, was a complete record of the inspection and would yield valid comparisons with the predictions of theoretical models. The exercise entailed visits by a nominated CEGB observer to 4 European NDT Laboratories at which the parametric studies were in progress; CISE (Milan); UKAEA (Harwell); UKAEA (Risley) and Vincotte (Brussels). This report presents the findings of those visits

  9. TIBER II/ETR [Engineering Test Reactor] nuclear shielding and optional tritium breeding system: An overview

    International Nuclear Information System (INIS)

    Lee, J.D.; Sawan, M.

    1987-01-01

    TIBER II, the Tokamak Ignition/Burn Experimental Reactor II, is a design concept developed as the US candidate for an International Engineering Test Reactor (ETR). An important objective of this design is to minimize cost by minimizing major radius while providing a wall loading greater than 1.0 MW/m2 and a total fluence greater than 3.0 MWY/m2 needed for blanket module testing. The shielding required for the superconducting TF coils is an important element in setting TIBER II's 3.0m major radius. 6 refs., 1 fig., 1 tab

  10. Comparative Pharmacokinetics Study of Icariin and Icariside II in Rats

    Directory of Open Access Journals (Sweden)

    Tao Cheng

    2015-12-01

    Full Text Available To explore the pharmacokinetic properties of icariin (ICA and icariside II (ICA II following intragastric and intravenous administration in rats, a rapid and sensitive method by using ultra-performance liquid chromatography–tandem mass spectroscopy (UPLC-MS/MS was developed and validated for the simultaneous quantification of ICA and ICA II in rat plasma. The quantification was performed by using multiple reaction monitoring of the transitions m/z 677.1/531.1 for ICA, 515.1/369.1 for ICA II and 463.1/301.1 for diosmetin-7-O-β-d-glucopyranoside (IS. The assay showed linearity over the concentration range of 1.03–1032 ng/mL, with correlation coefficients of 0.9983 and 0.9977. Intra- and inter-day precision and accuracy were within 15%. The lower limit of quantification for both ICA and ICA II was 1.03 ng/mL, respectively. The recovery of ICA and ICA II was more than 86.2%. The LC-MS/MS method has been successfully used in the pharmacokinetic studies of ICA and ICA II in rats. The results indicated that 91.2% of ICA was transformed into ICA II after oral administration by rats, whereas only 0.4% of ICA was transformed into ICA II after intravenous administration. A comparison of the pharmacokinetics of ICA and ICA II after oral administration revealed that the Cmax and AUC0–t of ICA II were 3.8 and 13.0 times higher, respectively, than those of ICA. However, after intravenous administration, the Cmax and AUC0–t of ICA II were about only 12.1% and 4.2% of those of ICA. These results suggest that ICA and ICA II have distinct pharmacokinetic properties, and the insights obtained facilitate future pharmacological action studies.

  11. Sensitization Profile to Allergens in Patients Using Multi-Test II

    Science.gov (United States)

    Maniglia, Sergio Fabricio; Tsuru, Fernanda Miyoko; Santos, Victor Carvalho dos; Ueda, Denis Massatsugu

    2014-01-01

    Introduction Medical intervention in allergies has broadened its perspective, also focusing in the quality of life of patients. Patients are instructed, before using pharmacotherapy agents, to avoid the causal agent. Objective This study aims to analyze the sensitization profile of patients with allergic complaints and identify possible characteristics specific to each age group and gender. Methods A descriptive cross-sectional study included data collected from medical records (from Multi-Test II database, Lincoln Diagnostics Inc. Decatur, Illinois) of 1,912 patients who underwent skin prick test from March to October 2013. Patients were organized and analyzed according to gender, age, and results of the allergens subtypes tested. Results The study was composed of 1,912 patients (60% male and 40% female) of ages between 3 and 87 years. Positive tests were more prevalent in quantity and intensity with the mites Dermatophagoides pteronyssinus and Dermatophagoides farinae, each with 60% of the total analyzed. In second place were pollens, especially Dactylis glomerata and Festuca pratensis. Conclusion The female and male sexes were equally atopic. Fungi and epithelia of dog and cat were not considered potential aeroallergens that could cause symptoms. However, mites are common in Paraná, Brazil. Further studies regarding the pollens are needed, as this study result diverged from the literature. PMID:25992129

  12. Some recriticality studies with SIMMER-II

    International Nuclear Information System (INIS)

    Bohl, W.R.

    1979-01-01

    The SIMMER-II code was applied to the problem of evaluating the potential for recriticality in an LMFBR HCDA. The phenomenology examined was based on the post SAS3D behavior in a CRBR LOF accident. The SIMMER-II results were found to be sensitive to the development of fuel blockages. If blockages were formed close to the core, the core-disruption phase of the behavior resulted from the significant energy required following SAS3D termination to raise the average steel temperature to saturation conditions; also material deposition near heat sinks eliminated condensation surfaces and induced core pressurization and fuel collapse. Excessive ramp rates (greater than $100/s) were judged to be unlikely, but improved knowledge and calculational treatments of the applicable phenomenology would be desirable

  13. Equilibrium Sorption Studies of Hg (II) Ions from Aqueous Solution ...

    African Journals Online (AJOL)

    The potential of swamp arum (Lasimorpha senegalensis) seeds as a low-cost adsorbent for the removal of Hg (II) ions from aqueous solution was investigated in this study. The influence of initial metal concentration on the percent adsorption of Hg (II) ions onto powdered swamp arum seeds was studied in a batch system ...

  14. Theory Testing Using Case Studies

    DEFF Research Database (Denmark)

    Møller, Ann-Kristina Løkke; Dissing Sørensen, Pernille

    2014-01-01

    The appropriateness of case studies as a tool for theory testing is still a controversial issue, and discussions about the weaknesses of such research designs have previously taken precedence over those about its strengths. The purpose of the paper is to examine and revive the approach of theory...... testing using case studies, including the associated research goal, analysis, and generalisability. We argue that research designs for theory testing using case studies differ from theorybuilding case study research designs because different research projects serve different purposes and follow different...... research paths....

  15. Americium/Curium Vitrification Pilot Tests - Part II

    International Nuclear Information System (INIS)

    Marra, J.E.; Baich, M.A.; Fellinger, A.P.; Hardy, B.J.; Herman, D.T.; Jones, T.M.; Miller, C.B.; Miller, D.H.; Snyder, T. K.; Stone, M.E.

    1998-05-01

    Isotopes of americium (Am) and curium (Cm) were produced in the past at the Savannah River Site (SRS) for research, medical, and radiological applications. These highly radioactive and valuable isotopes have been stored in an SRS reprocessing facility for a number of years. Vitrification of this solution will allow the material to be more safely stored until it is transported to the DOE Oak Ridge Reservation for use in research and medical applications. A previous paper described operation results from the Am-Cm Melter 2A pilot system, a full-scale non-radioactive pilot facility. This paper presents the results from continued testing in the Pilot Facility and also describes efforts taken to look at alternative vitrification process operations and flowsheets designed to address the problems observed during melter 2A pilot testing

  16. Gas Generation from K East Basin Sludges - Series II Testing

    International Nuclear Information System (INIS)

    Bryan, Samuel A.; Delegard, Calvin H.; Schmidt, Andrew J.; Sell, Rachel L.; Silvers, Kurt L.; Gano, Susan R.; Thornton, Brenda M.

    2001-01-01

    This report describes work to examine the gas generation behavior of actual K East (KE) Basin floor, pit and canister sludge. Mixed and unmixed and fractionated KE canister sludge were tested, along with floor and pit sludges from areas in the KE Basin not previously sampled. The first report in this series focused on gas generation from KE floor and canister sludge collected using a consolidated sampling technique. The third report will present results of gas generation testing of irradiated uranium fuel fragments with and without sludge addition. The path forward for management of the K Basin Sludge is to retrieve, ship, and store the sludge at T Plant until final processing at some future date. Gas generation will impact the designs and costs of systems associated with retrieval, transportation and storage of sludge

  17. Introduction to non-destructive testing of materials: part II

    International Nuclear Information System (INIS)

    Ahmed, M.; Ahmed, B.

    2001-01-01

    Ultrasonic waves are mechanical vibrations that require a medium, which functions as carrier. Ultrasonics are widely used in non-destructive testing of materials in which high frequency sound waves are introduced into the material being inspected. If the frequency of sound waves in within the range 10 to 20,000 Hz, the sound is audible, i.e. the range of hearing, above 20,000 Hz, the sound waves are referred to as Ultrasound or Ultrasonics. Sound waves do not cause any permanent change in material although its transient presence is very noticeable. An energy transport through a sound wave is possible only when constituent particles are connected to each other by elastic forces. Liquids and Gases are also suitable media for the transmission of sound. In vacuum no matter exists and thus no sound transmission is possible. At the end of this article advantages and limitations of ultrasonic testing are also given. (A.B.)

  18. Supercritical water oxidation data acquisition testing. Final report, Volume II

    International Nuclear Information System (INIS)

    1996-11-01

    Supercritical Water Oxidation (SCWO) technology holds great promise for treating mixed wastes, in an environmentally safe and efficient manner. In the spring of 1994 the US Department of Energy (DOE), Idaho Operations Office awarded Stone ampersand Webster Engineering Corporation, of Boston Massachusetts and its sub-contractor MODAR, Inc. of Natick Massachusetts a Supercritical Water Oxidation Data Acquisition Testing (SCWODAT) program. The SCWODAT program was contracted through a Cooperative Agreement that was co-funded by the US Department of Energy and the Strategic Environmental Research and Development Program. The SCWODAT testing scope outlined by the DOE in the original Cooperative Agreement and amendments thereto was initiated in June 1994 and successfully completed in December 1995. The SCWODAT program provided further information and operational data on the effectiveness of treating both simulated mixed waste and typical Navy hazardous waste using the MODAR SCWO technology

  19. Proof tests of irradiated and unirradiated EBR-II subassembly ducts

    International Nuclear Information System (INIS)

    Ruther, W.E.; Chopra, P.S.; Lambert, J.D.B.

    1977-01-01

    A series of dynamic pressure tests have been conducted within EBR-II subassembly ducts. The tests were designed to simulate bursting of a driver-fuel element in a cluster of such elements at their burnup limit during off-normal conditions in EBR-II. The major objective of the tests was to assure that such failure, which might cause rapid release of stored fission gas, would not deform or otherwise damage subassembly ducts in a way that would hinder movement of a control rod. The test results are described

  20. Quality Assurance Program Plan for TRUPACT-II Gas Generation Test Program

    International Nuclear Information System (INIS)

    2002-01-01

    The Gas Generation Test Program (GGTP), referred to as the Program, is designed to establish the concentration of flammable gases and/or gas generation rates in a test category waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II). The phrase 'gas generationtesting' shall refer to any activity that establishes the flammable gas concentration or the flammable gas generation rate. This includes, but is not limited to, measurements performed directly on waste containers or during tests performed on waste containers. This Quality Assurance Program Plan (QAPP) documents the quality assurance (QA) and quality control (QC) requirements that apply to the Program. The TRUPACT-II requirements and technical bases for allowable flammable gas concentration and gas generation rates are described in the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC).

  1. Seismic II over I Drop Test Program results and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the {open_quotes}sources{close_quotes} and {open_quotes}targets{close_quotes} requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources.

  2. Seismic II over I Drop Test Program results and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the [open quotes]sources[close quotes] and [open quotes]targets[close quotes] requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources.

  3. Seismic II over I Drop Test Program results and interpretation

    International Nuclear Information System (INIS)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the open-quotes sourcesclose quotes and open-quotes targetsclose quotes requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources

  4. Case Study: Testing with Case Studies

    Science.gov (United States)

    Herreid, Clyde Freeman

    2015-01-01

    This column provides original articles on innovations in case study teaching, assessment of the method, as well as case studies with teaching notes. This month's issue discusses using case studies to test for knowledge or lessons learned.

  5. A Study on Individualized Tests

    Directory of Open Access Journals (Sweden)

    Metin YAŞAR

    2017-12-01

    Full Text Available This study aims to compare KR-20 reliability levels of “Paper and Pencil Test” developed according to Classical Test Theory and “Individualized Test” developed according to Item Response Theory (Two-Parameter Logistic Model, and the correlation levels of skill measurements obtained via these two methods in a group of students. Individualized test developed in accordance with the Two-Parameter Logistic Model was applied by means of a question pool consisting of 61 multiple-choice items which can be answered in 13 steps. On the other hand, a paper and pencil test of 47 multiple-choice items was applied to the sample student group. After the test developed according to these two methods was applied to the same group, KR-20 reliability coefficient was calculated as 0.67 for the individualized test and as 0.75 for the paper and pencil test prepared according to Classical test theory. Calculated KR-20 reliability coefficients obtained from the study were converted into Fisher Z and tested at the significance level of 0.05. No meaningful difference was detected at the 0.05 significant difference level between the two KR-20 reliability coefficients obtained from the two methods. Pearson Product-Moment Correlation Coefficient was calculated as 0.36 between the points of the individualized test and the measurement results of the paper and pencil test. A positive yet low correlation was observed between the measurement results obtained from the tests developed according to both methods. Consequently, it was seen that at the 0.05 significance level there was no statistically significant difference between KR-20 reliability coefficients of the tests developed according to the two methods and that there was a low correlation between the skill measurements of the students in both tests, but there was no significant correlation at the 0.05 significance level between the skill measurements obtained from both tests.

  6. Multiphoton production and tests of QED at LEP-II

    International Nuclear Information System (INIS)

    Winter, M.

    2001-01-01

    Data collected by the 4 LEP collaboration from 1995 to 2000 at collision energies ranging from 130 to 208 GeV were used to measure the cross-section of the process e + e - →γγ(γ). QED predictions for this reaction were tested with a few per-cent accuracy and manifestations of physics beyond the Standard Model (SM) were investigated. Preliminary lower bounds on the cut-off parameter Λ ± , the mass of an excited electron, the string mass scale underlying low-scale Quantum Gravity and on energy scales expression various contact interactions were derived. (author)

  7. Durability testing with West Valley borosilicate glass composition- Phase II

    International Nuclear Information System (INIS)

    Macedo, P.B.; Finger, S.M.; Barkatt, A.A.; Pegg, I.L.; Feng, X.; Freeborn, W.P.

    1988-06-01

    This report presents the research performed by the Catholic University of America Vitreous State Laboratory (VSL) during FY 1987 in support of the West Valley Demonstration Project (WVDP) nuclear waste vitrification process. A principal objective of this work is the optimization of the glass composition be used for the vitrification of the liquid high-level waste generated at West Valley during nuclear fuel reprocessing. This report discusses (1) the experimental investigations to optimize the reference glass composition (the current leading candidates are WVCM-50 and ATM-10) for the WVDP vitrification process; (2) the systematic experimental investigation performed to determine the effects of compositional variations in WVCM-50 and WV-205 reference glasses on their viscosity and durability (including initial results of long-term leach tests of WVCM-50 under repository conditions); (3) the development of short-time and predictive leach tests; (4) the development of a process model for the West Valley vitrification process which predicts the range of glass compositions which may be encountered during normal operations and the effects of deviations in process control parameters; and (5) the development of product models for predicting the durability and viscosity of nuclear waste glasses

  8. Evaluation of LLTR Series II Test A-3 results

    International Nuclear Information System (INIS)

    Amos, J.C.; Chen, K.; Meyer, R.A.; Odegaard, T.K.; Whipple, J.C.

    1980-11-01

    Of the five secondary tubes failed in Test A-3, two were failed by impingement wastage, and the other three appear to have been caused by overheating possibly augmented by wastage. Since no secondary tube failures occurred during large leak tests, this spports the hypthesis that a small initial leak can create much more damage on neighboring tubes than an initial large leak. The overheating falures occurred in about 20 seconds after a second large hole had been produced in a thin wall (non-prototypical) primary tube. Continued water injection under static or low sodium flow conditions following an initial small leak will produce high temperatures which can result in deformation (bowing) of 2-1/4 Cr-1 Mo steam tubes and interference at the tube-tubespacer interface. The damage caused by either impingement wastage or overheating will occur at or above the elevation plane of the initial leak. If water/steam injection continues after removal of the sodium, water steam blanketing will cool the tubes heated by the SWR. Additional tube failures can be caused by overheating prior to rupture disc operation when leak rate is increased by secondary tube penetrations caused by wastage. Acoustic emission measurement provides a rapid means of leak detection for intermediate size leaks

  9. Alcatel-Lucent Network Routing Specialist II (NRS II) Self-Study Guide Preparing for the NRS II Certification Exams

    CERN Document Server

    Warnock, Glenn

    2011-01-01

    The definitive resource for the NRS II exams—three complete courses in a book Alcatel-Lucent is a world leader in designing and developing scalable systems for service providers. If you are a network designer or operator who uses Alcatel-Lucent's 7750 family of service routers, prepare for certification as an A-L network routing specialist with this complete self-study course. You'll get thorough preparation for the NRS II exams while you learn to build state-of-the-art, scalable IP/MPLS-based service networks. The book provides you with an in-depth understanding of the protocols and tec

  10. Mark II containment 1/6-scale pressure suppression test program: data report no. 2

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Okazaki, Motoaki; Namatame, Ken; Shiba, Masayoshi

    1979-08-01

    This report documents experimental data from the first test phase of the Mark II Containment 1/6-Scale Pressure Suppression Test. The 1/6-Scale Test was initiated in December, 1976, to investigate the thermohydraulic responses of a BWR Mark II pressure suppression system to a postulated loss-of-coolant accident (LOCA), by means of scale model experiments. From January to June, 1977, a series of tests were performed for the Japanese BWR Owners' Group. These tests consisted of eight air-blowdown pool swell tests, three steam-blowdown pool swell tests, and twelve steam condensation tests. The dynamic responses of pressure and pool water level during the blowdown, pressure oscillation and chugging phenomena associated with unsteady condensation of steam were measured. (author)

  11. Can neuropsychological testing produce unequivocal evidence of brain damage? II. Testing for right vs. left differences.

    Science.gov (United States)

    Reitan, Ralph M; Wolfson, Deborah

    2008-01-01

    Sensation and perception, as well as motor functions, have played an important role in the history of psychology. Although tests of these abilities are sometimes included in neuropsychological assessments, comparisons of intraindividual performances on the two sides of the body (as a basis for drawing conclusions and comparisons about the functional status of the two cerebral hemispheres) are in many instances neglected or considered only casually. This study, utilizing several motor and sensory-perceptual tests, compared intraindividual differences on the two sides of the body in a group of controls and a group of persons with brain damage. The results indicated that the sensory-perceptual tests were particularly effective in differentiating the groups. More than 60% of the group with brain damage had greater differences on the two sides of the body than did any of the controls. These findings suggest that a substantial proportion of persons with cerebral disease or damage may be subject to unequivocal identification using sensory-perceptual tests that take only about 20 minutes to administer. These tests may serve a valuable role as an adjunct to comprehensive neuropsychological evaluation and should be further evaluated in this respect.

  12. Evaluation of CCTF Core-II second acceptance Test C2-AC2 (Run 052)

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Murao, Yoshio

    1984-03-01

    In order to investigate the thermo-hydrodynamic behavior in a PWR during the reflood phase of the LOCA, large scale reflooding tests have been conducted at JAERI using the CCTF Core-I and Core-II facilities. This report presents the investigation on the difference in the thermo-hydrodynamic behavior observed between in the CCTF Core-I and Core-II facilities. For this purpose the test data of the second CCTF Core-II acceptance test C2-AC2 (Run 052) were evaluated by using the data of the Test CL-21 (Run 040) in the Core-I test series. The experimental conditions for these two tests were almost identical. Comparing the data of those two tests, the following is obtained. 1. The system behavior observed in the Core-II facility was nearly identical to that observed in the Core-I facility. 2. The core behavior observed in the Core-II facility was also nearly identical to that observed in the Core-I facility except for the top quenching behavior. 3. The differences in the top quenching behavior between the two facilities were as follows: (1) The selective occurrence of top quenching below the open holes of the upper core support plate observed in the Core-I facility was not observed in the Core-II facility. (2) Top quenching tended to occur less in the Core-II facility in the region where the initial average linear power density was over 1.69 kW/m. (author)

  13. Definition of task (Phase II) B, 'Leak testing'; Definicija zadatka (II faza) B, 'Ispitivanje hermeticnosti'

    Energy Technology Data Exchange (ETDEWEB)

    Pavicevic, M; Nikolic, M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1963-01-15

    In order to ensure safe Ra reactor operation and fulfilling the conditions for performing irradiation experiments it was necessary to test and verify the leak tightness of the sample containers and thermocouples, as well as the irradiation capsule before it was placed in the VISA-2 channel. Leak testing of VISA-2 channel with capsules and thermocouples was done before and after it was built-in the reactor. [Serbo-Croat] U cilju bezbednosti i sigurnosti rada reaktora RA i ispunjavanja uslova ozracivanja izvrsena je provera hermeticnosti kenera sa uzorcima i termoparovima, kao i hermeticnost kapsule pre ugradjivanja kapsule u kanal VISA-2. Izvrseno je i ispitivanje hermeticnosti kanala VISA-2 sa kapsulama i termoparovima pre ugradjivanja u reaktor i posle montaze.

  14. Process optimization and mechanistic studies of lead (II): Aspergillus ...

    African Journals Online (AJOL)

    The lead (II) accumulation potential of various biosorbent had been widely studied in the last few years, but an outstanding Pb(II) accumulating biomass still seems crucial for bringing the process to a successful application stage. This investigation describes the use of non-living biomass of Aspergillus caespitosus for ...

  15. Adsorption and thermodynamic studies of Cu(II) and Zn(II) on organofunctionalized-kaolinite

    International Nuclear Information System (INIS)

    Guerra, Denis Lima; Airoldi, Claudio; Sousa, Kaline S. de

    2008-01-01

    Kaolinite-bearing clay samples from Perus, Sao Paulo state, Brazil, were used for chemical modification process with dimethyl sulfoxide and organofunctionalized with the silyating agent (RO) 3 Si(CH 2 ) 3 NH(CH 2 ) 2 NH 2 in the present study. The resulting material and natural kaolinite were subjected adsorpion process with Cu(II) and Zn(II) from aqueous solution at pH 6.0 and controlated temperature of 298 K. The Langmuir adsorption isotherm model has been applied to fit the experimental data. The results showed that the chemical modification process increases the basal spacing of the natural kaolinite from 0.711 to 0.955 nm. The energetic effects caused by Cu(II) and Zn(II) interactions were determined through calorimetric titration at the solid-liquid interface and gave a net thermal effect that enabled the calculation of the exothermic values and the equilibrium constant

  16. Fingerprinting dark energy. II. Weak lensing and galaxy clustering tests

    International Nuclear Information System (INIS)

    Sapone, Domenico; Kunz, Martin; Amendola, Luca

    2010-01-01

    The characterization of dark energy is a central task of cosmology. To go beyond a cosmological constant, we need to introduce at least an equation of state and a sound speed and consider observational tests that involve perturbations. If dark energy is not completely homogeneous on observable scales, then the Poisson equation is modified and dark matter clustering is directly affected. One can then search for observational effects of dark energy clustering using dark matter as a probe. In this paper we exploit an analytical approximate solution of the perturbation equations in a general dark energy cosmology to analyze the performance of next-decade large-scale surveys in constraining equation of state and sound speed. We find that tomographic weak lensing and galaxy redshift surveys can constrain the sound speed of the dark energy only if the latter is small, of the order of c s < or approx. 0.01 (in units of c). For larger sound speeds the error grows to 100% and more. We conclude that large-scale structure observations contain very little information about the perturbations in canonical scalar field models with a sound speed of unity. Nevertheless, they are able to detect the presence of cold dark energy, i.e. a dark energy with nonrelativistic speed of sound.

  17. Operating and test experience of EBR-II

    International Nuclear Information System (INIS)

    Sackett, J.I.

    1991-01-01

    EBR-2 has operated for 27 years, the longest for any Liquid Metal Reactor (LMR) power plant. During that time, much has been learned about successful LMR operation and design. The basic lesson is that conversatism in design can pay significant dividends in operating reliability. Furthermore, such conservatism need not mean high cost. The EBR-2 system emphasizes simplicity, minimizing the number of valves in the heat transport system, for example, and simplifying the primary heat-transport-system layout. Another lesson is that emphasizing reliability of the steam generating system at the sodium-water interface (by using duplex tubes in the case of EBR-2) has been well worth the higher initial costs; no problems with leakage have been encountered in EBR-2's operating history. Locating spent fuel storage in the primary tank and providing for decay heat removal by natural connective flow have also been contributors to EBR-2's success. The ability to accommodate loss of forced cooling or loss of heat sink passively has resulted in benefits for simplification, primarily through less reliance on emergency power and in not requiring the secondary sodium or steam systems to be safety grade. Also, the ''piped-pool '' arrangement minimizes thermal stress to the primary tank and enhances natural convective flow. These benefits have been realized through a history of operation that has seen EBR-2 evolve through four major phases in its test programs, culminating in its present mission as the Integral Fast Rector (IFR) prototype. 20 refs., 8 figs., 1 tab

  18. Test beam results for an upgraded forward tagger of the L3 experiment at LEP II

    International Nuclear Information System (INIS)

    Chemarin, M.; Depasse, P.; Fay, J.; Felcini, M.; Fredj, L.; Ille, B.; Nessi-Tedaldi, F.; Susinno, G.F.

    1994-01-01

    We have tested new scintillator modules with silicon photodiode readout for the upgraded Active Lead Rings (ALR) of the L3 detector at LEP II. Results are presented from data recorded in muon and electron test beams with particular emphasis on the light production and collection as a function of the particle impact position on the scintillator modules. The results from the beam test data will be used for the design of the readout and trigger electronics in conjunction with the required ALR performance as an electron tagger and beam background monitor at LEP II. ((orig.))

  19. He II Heat Exchanger Test Unit for the LHC Inner Triplet

    CERN Document Server

    Blanco-Viñuela, E; Huang, Y; Nicol, T H; Peterson, T; Van Weelderen, R

    2002-01-01

    The Inner Triplet Heat Exchanger Test Unit (IT-HXTU) is a 30-m long thermal model designed at Fermilab, built in US industry, fully automated and tested at CERN as part of the US LHC program to develop the LHC Interaction Region quadrupole system. The cooling scheme of the IT-HXTU is based on heat exchange between stagnant pressurized He II in the magnet cold mass and saturated He II (two-phase) flowing in a heat exchanger located outside of and parallel to the cold mass. The purposes of this test are, among others, to validate the proposed cooling scheme and to define an optimal control strategy to be implemented in the future LHC accelerator. This paper discusses the results for the heat exchanger test runs and emphasizes the thermal and hydraulic behavior of He II for the inner triplet cooling scheme.

  20. PISC II: Parametric studies. Summary of the PISC II Parametric studies on the Effect of defect Characteristics (EDC)

    International Nuclear Information System (INIS)

    Crutzen, S.; Murgatroyd, R.; Dombret, P.

    1989-09-01

    Studies on the effect of defect characteristics and selected inspection parameters on the detection and sizing of defects in ferritic steel blocks have been performed by: - United Kingdom Atomic Energy Authority (UKAEA, Risley and Harwell), - CISE, (Italy, Milan), - VINCOTTE (Belgium, Brussels), - CEC, JRC (Ispra Site; complementary measurements), as part of a larger Commission of the European Communities (CEC) programme in support to the PISC (Programme for the Inspection of Steel Components), jointly sponsored by OECD (Organization for Economic Coordination and Development) and CEC and operated by the Joint Research Centre (JRC), Ispra Establishment. The purpose of the programme was to acquire reliable experimental data that could be used both to explain results of the PISC I and II Round Robin Tests (RRT) and to test and validate theoretical models of the ultrasonic testing techniques. For these studies, eighteen test blocks were manufactured by JRC Ispra, Operating Agent and Reference Laboratory of PISC. A range of defect types was inserted with great care covering aspects such as defect shape, defect size, defect surface roughness, defect position in depth, defect orientation. Several of these blocks (defects) were selected by the participating institutions. Each of these participants applied well specified usual ultrasonic techniques: echo techniques, tandem technique, focusing probe technique at 45 0 and time of flight diffraction (TOFD). Results of such measurements propose clear correlation between defect characteristics and amplitude of response of these defects

  1. DNA-Binding Studies of Some Potential Antitumor 2,2'-bipyridine Pt(II)/Pd(II) Complexes of piperidinedithiocarbamate. Their Synthesis, Spectroscopy and Cytotoxicity.

    Science.gov (United States)

    Mansouri-Torshizi, Hassan; Eslami-Moghadam, Mahboube; Divsalar, Adeleh; Saboury, Ali-Akbar

    2011-12-01

    In this study two platinum(II) and palladium(II) complexes of the type [M(bpy)(pip-dtc)]NO3 (where M=Pt(II) or Pd(II), bpy=2,2'-bipyridine, pip-dtc=piperidinedithiocarbamate) were synthesized by reaction between diaquo-2,2'-bipyridine Pt(II)/Pd(II) nitrate and sodium salt of dithiocarbamate. These cationic water soluble complexes were characterized by elemental analysis, molar conductance, IR, electronic and 1H NMR spectroscopic studies. The cyclic dithiocarbamate was found to coordinate as bidentate fasion with Pt(II) or Pd(II) center. Their biological activities were tested against chronic myelogenous leukemia cell line, K562, at micromolar concentration. The obtained cytotoxic concentration (IC50) values were much lower than cisplatin. The interaction of these complexes with highly polymerized calf thymus DNA (ct-DNA) was extensively studied by means of electronic absorption, fluorescence, circular dichroism and other measurements. The experimental results, thermodynamic and binding parameters, suggested that these complexes cooperatively bind to DNA presumably via intercalation. Moreover, the tendency of the Pt(II) complex to interact with DNA was more than that of Pd(II) complex.

  2. Modification of EBR-II plant to conduct loss-of-flow-without-scram tests

    Energy Technology Data Exchange (ETDEWEB)

    Messick, N C; Betten, P R; Booty, W F; Christensen, L J; Fryer, R M; Mohr, D; Planchon, H P; Radtke, W H

    1987-04-01

    This paper describes the details of and the philosophy behind changes made to the EBR-II plant in order to conduct loss-of-flow-without-scram tests. No changes were required to conduct loss-of-heat-sink-without-scram tests.

  3. Modification of EBR-II plant to conduct loss-of-flow-without-scram tests

    International Nuclear Information System (INIS)

    Messick, N.C.; Betten, P.R.; Booty, W.F.; Christensen, L.J.; Fryer, R.M.; Mohr, D.; Planchon, H.P.; Radtke, W.H.

    1987-01-01

    This paper describes the details of and the philosophy behind changes made to the EBR-II plant in order to conduct loss-of-flow-without-scram tests. No changes were required to conduct loss-of-heat-sink-without-scram tests. (orig.)

  4. Chracterization of the beam from the RFQ of the PIP-II Injector Test

    Energy Technology Data Exchange (ETDEWEB)

    Shemyakin, A. [Fermilab; Carneiro. J.-P., Carneiro. J.-P. [Fermilab; Hanna, B. [Fermilab; Prost, L. [Fermilab; Saini, A. [Fermilab; Scarpine, V. [Fermilab; Sista, V. L.S. [Bhabha Atomic Res. Ctr.; Steimel, J. [Fermilab

    2017-05-01

    A 2.1 MeV, 10 mA CW RFQ has been installed and commissioned at the Fermilab’s test accelerator known as PIP-II Injector Test. This report describes the measure-ments of the beam properties after acceleration in the RFQ, including the energy and emittance.

  5. Case studies in ultrasonic testing

    International Nuclear Information System (INIS)

    Prasad, V.; Satheesh, C.; Varde, P.V.

    2015-01-01

    Ultrasonic testing is widely used Non Destructive Testing (NDT) method and forms the essential part of In-service inspection programme of nuclear reactors. Main application of ultrasonic testing is for volumetric scanning of weld joints followed by thickness gauging of pipelines and pressure vessels. Research reactor Dhruva has completed the first In Service Inspection programme in which about 325 weld joints have been volumetrically scanned, in addition to thickness gauging of 300 meters of pipe lines of various sizes and about 24 nos of pressure vessels. Ultrasonic testing is also used for level measurements, distance measurements and cleaning and decontamination of tools. Two case studies are brought out in this paper in which ultrasonic testing is used successfully for identification of butterfly valve opening status and extent of choking in pipe lines in Dhruva reactor systems

  6. Evaluation report on CCTF Core-II reflood test C2-4 (Run 62)

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Iguchi, Tadashi; Sugimoto, Jun; Akimoto, Hajime; Murao, Yoshio; Okabe, Kazuharu.

    1985-03-01

    This report presents a data evaluation of the CCTF Core-II test C2-4 (Run 62), which was conducted on May 12, 1983. This test was conducted to investigate the reproducibility of tests in the CCTF Core-II test series. Therefore, the initial and boundary conditions of the present test were determined to be the same as those for the previously performed base case test (Test C2-SH1). Comparing the data of the present test with those of Test C2-SH1, the following results are obtained. (1) The initial and boundary conditions for the two tests were nearly identical except the temperature of the core barrel and the lower plenum fluid. The difference in the latter is considered to result in the difference in the core inlet subcooling of about 6 K at most. (2) The system behavior was almost identical. (3) The core cooling behavior was also nearly identical except a little difference in the rod surface temperature in the upper part of the high power region. (4) Taking account that the difference mentioned above in item (3) is small and can be explained qualitatively to be caused by the difference in the core inlet subcooling mentioned above in item (1), it is considered practically that there is the reproducibility of the thermo-hydrodynamic behavior in the CCTF Core-II tests. (author)

  7. Test of the HAPD light sensor for the Belle II Aerogel RICH

    Science.gov (United States)

    Yusa, Y.; Adachi, I.; Dolenec, R.; Hayata, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kindo, H.; Kobayashi, T.; Korpar, S.; Krizan, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Pestotnik, R.; Santelj, L.; Sumiyoshi, T.; Tabata, M.; Yonenaga, M.

    2017-12-01

    The Aerogel Ring-Imaging Cherenkov detector (ARICH) is being installed in the endcap region of Belle II spectrometer to identify particles from B meson decays by detecting the Cherenkov ring image from aerogel radiators. To detect single photons, high-sensitive photon detector which has wide effective area (∼70 mm × 70 mm), a Hybrid Avalanche Photo Detector (HAPD), has been developed in a collaboration with Hamamatsu K.K. The HAPD consists of hybrid structure of a vacuum tube and an avalanche photodiode (APD). It can be operated in 1.5 T magnetic field of the spectrometer and withstands the radiation levels expected in the Belle II experiment. There are two steps of electric pulse amplification: acceleration of photo-electron in electric field in the vacuum tube part and electron avalanche in the APD part resulting in total gain of order 105. For the ARICH, we use 420 HAPDs in total. Before installing them, we performed quality assessment studies such as measurements of dark current, noise level, signal-to-noise ratio and two-dimensional scan with laser illumination. We also measured quantum efficiency of the photocathode. During the HAPD performance tests in the magnetic field, we observed very large signal pulses which cause long dead time of the readout electronics in some of the HAPDs. We have carried out a number of studies to understand this phenomenon, and have found a way to mitigate it and suppress the degradation of the ARICH performance. In this report, we will show a summary of the HAPD performance and quality assessment measurements including validation in the magnetic field for all of the HAPDs manufactured for the ARICH in the Belle II.

  8. Theory Testing Using Case Studies

    DEFF Research Database (Denmark)

    Sørensen, Pernille Dissing; Løkke, Ann-Kristina

    2006-01-01

    design. Finally, we discuss the epistemological logic, i.e., the value to larger research programmes, of such studies and, following Lakatos, conclude that the value of theory-testing case studies lies beyond naïve falsification and in their contribution to developing research programmes in a progressive...

  9. LNG cascading damage study. Volume I, fracture testing report.

    Energy Technology Data Exchange (ETDEWEB)

    Petti, Jason P.; Kalan, Robert J.

    2011-12-01

    As part of the liquefied natural gas (LNG) Cascading Damage Study, a series of structural tests were conducted to investigate the thermal induced fracture of steel plate structures. The thermal stresses were achieved by applying liquid nitrogen (LN{sub 2}) onto sections of each steel plate. In addition to inducing large thermal stresses, the lowering of the steel temperature simultaneously reduced the fracture toughness. Liquid nitrogen was used as a surrogate for LNG due to safety concerns and since the temperature of LN{sub 2} is similar (-190 C) to LNG (-161 C). The use of LN{sub 2} ensured that the tests could achieve cryogenic temperatures in the range an actual vessel would encounter during a LNG spill. There were four phases to this test series. Phase I was the initial exploratory stage, which was used to develop the testing process. In the Phase II series of tests, larger plates were used and tested until fracture. The plate sizes ranged from 4 ft square pieces to 6 ft square sections with thicknesses from 1/4 inches to 3/4 inches. This phase investigated the cooling rates on larger plates and the effect of different notch geometries (stress concentrations used to initiate brittle fracture). Phase II was divided into two sections, Phase II-A and Phase II-B. Phase II-A used standard A36 steel, while Phase II-B used marine grade steels. In Phase III, the test structures were significantly larger, in the range of 12 ft by 12 ft by 3 ft high. These structures were designed with more complex geometries to include features similar to those on LNG vessels. The final test phase, Phase IV, investigated differences in the heat transfer (cooling rates) between LNG and LN{sub 2}. All of the tests conducted in this study are used in subsequent parts of the LNG Cascading Damage Study, specifically the computational analyses.

  10. Results and implications of the EBR-II inherent safety demonstration tests

    International Nuclear Information System (INIS)

    Planchon, H.P.; Golden, G.H.; Sackett, J.I.; Mohr, D.; Chang, L.K.; Feldman, E.E.; Betten, P.R.

    1987-01-01

    On April 3, 1986 two milestone tests were conducted in Experimental Breeder Reactor-2 (EBR-II). The first test was a loss of flow without scram and the second was a loss of heat sink without scram. Both tests were initiated from 100% power and in both tests the reactor was shut down by natural processes, principally thermal expansion, without automatic scram, operator intervention or the help of special in-core devices. The temperature transients during the tests were mild, as predicted, and there was no damage to the core or reactor plant structures. In a general sense, therefore, the tests plus supporting analysis demonstrated the feasibility of inherent passive shutdown for undercooling accidents in metal-fueled LMRs. The results provide a technical basis for future experiments in EBR-II to demonstrate inherent safety for overpower accidents and provide data for validation of computer codes used for design and safety analysis of inherently safe reactor plants

  11. Studying a disease with no home--lessons in trial recruitment from the PATCH II study.

    LENUS (Irish Health Repository)

    Thomas, Kim S

    2010-01-01

    Cellulitis is a very common condition that often recurs. The PATCH II study was designed to explore the possibility of preventing future episodes of cellulitis, with resultant cost savings for the NHS. This was the first trial to be undertaken by the UK Dermatology Clinical Trials Network. As such, it was the first to test a recruitment model that involved many busy clinicians each contributing just a few patients.

  12. Pre-test evaluation of LLTR series II Test A-7

    International Nuclear Information System (INIS)

    Knittle, D.

    1981-03-01

    The purpose of this report is to present pre-test predictions of pressure histories for the A-7 test to be conducted in the Large Leak Test Rig (LLTR) at the Energy Technology Engineering Center (ETEC) in April 1981

  13. Power supply for the Spanish stellarator TJ-II, design, construction, and tests

    Energy Technology Data Exchange (ETDEWEB)

    Perez, A.; Lucia, C.; Alberdi, B.; Del Rio, J.M. [JEMA SA, Lasarte-Oria (Spain); Almoguera, L.; Blaumoser, M.; Kirpitchev, I.; Mendez, P. [Asociacion EURATOM-CIEMAT para Fusion, Madrid (Spain)

    1995-12-31

    Most of the components of the electrical power supply system of the new TJ-II stellarator, which is under construction in Madrid (Spain), are now constructed and tested. The flywheel synchronous generator is still under construction and its tests are planned for the end of 1995. The power plant is described in detail as well as the tests which have been carried out and their results.

  14. Spectral, thermal, electrochemical and analytical studies on Cd(II) and Hg(II) thiosemicarbazone complexes

    Science.gov (United States)

    El-Asmy, A. A.; El-Gammal, O. A.; Saleh, H. S.

    2008-11-01

    The coordination characteristic of the investigated thiosemicarbazones towards hazard pollutants, Cd(II) and Hg(II), becomes the first goal. Their complexes have been studied by microanalysis, thermal, electrochemical and spectral (electronic, IR and MS) studies. The substitutent (salicylaldehyde, acetophenone, benzophenone, o-hydroxy- p-methoxybenzophenone or diacetylmonoxime) plays an important role in the complex formation. The coordination sites were the S for thiosemicarbazide (HTS); NN for benzophenone thiosemicarbazone (HBTS); NS for acetophenone thiosemicarbazone (HATS) and salicylaldehyde thiosemicarbazone (H 2STS); NNS or NSO for diacetylmonoxime thiosemicarbazone (H 2DMTS). The stability constants of Hg(II) complexes were higher than Cd(II). The kinetic and thermodynamic parameters for the different thermal decomposition steps in the complexes have been evaluated. The activation energy values of the first step ordered the complexes as: [Cd(H 2STS)Cl 2]H 2O > [Cd(H 2DAMTS)Cl 2] > [Cd(HBTS) 2Cl 2]2H 2O > [Cd(HATS) 2Cl 2]. The CV of [Cd(H 2STS)Cl 2]H 2O and [Hg(HBTS)Cl 2] were recorded. The use of H 2DMTS as a new reagent for the separation and determination of Cd(II) ions from water and some synthetic samples using flotation technique is aimed to be discussed.

  15. Short-interval test-retest interrater reliability of the Dutch version of the structured clinical interview for DSM-IV personality disorders (SCID-II)

    NARCIS (Netherlands)

    Weertman, A; ArntZ, A; Dreessen, L; van Velzen, C; Vertommen, S

    2003-01-01

    This study examined the short-interval test-retest reliability of the Structured Clinical Interview (SCID-II: First, Spitzer, Gibbon, & Williams, 1995) for DSM-IV personality disorders (PDs). The SCID-II was administered to 69 in- and outpatients on two occasions separated by 1 to 6 weeks. The

  16. Studies on Manganese (II), Cobalt (II) and Cadmium (II) complexes with L-Cystine

    International Nuclear Information System (INIS)

    Hossain, M. Alamgir; Ahmed, A.H. Moinuddin; Iqbal, M. Monocheher

    1995-01-01

    A study has been carried out to prepare the manganese, cobalt and cadmium complexes of L-cystine using the metal salts and lithium cystinate. The crystalline 1:1 stoichiometric complexes with the empirical formulae of [Mn(SCH 2 CHNH 2 COO) 2 ], [Co(SCH 2 CHNH 2 COO) 2 ] and [Cd(SCH 2 CHNH 2 COO) 2 ] are obtained from the reaction of equimolar amount of the corresponding metal ions and ligand in aqueous solution. The complexes have been characterized by chemical analyses, infrared and ultraviolet spectra, magnetic measurements, optical and thermal decomposition methods. Studies show that L-cystine behaves as tetradentate ligand forming chelates with metal ions where the bonding sites of the ligand are the carboxylate O and the amino N atoms. 15 refs., 2 tables, 3 figs (author)

  17. Studies of heat transport to forced-flow He II

    International Nuclear Information System (INIS)

    Dresner, L.; Kashani, A.; Van Sciver, S.W.

    1985-01-01

    Analytical and experimental studies of heat transport to forced-flow He II are reported. The work is pertinent to the transfer of He II in space. An analytical model has been developed that establishes a condition for two-phase flow to occur in the transfer line. This condition sets an allowable limit to the heat leak into the transfer line. Experimental measurements of pressure drop and flow meter performances indicate that turbulent He II can be analyzed in terms of classical pressure drop correlations

  18. Physicochemical impact studies of gamma rays on "aspirin" analgesics drug and its metal complexes in solid form: Synthesis, spectroscopic and biological assessment of Ca(II), Mg(II), Sr(II) and Ba(II) aspirinate complexes

    Science.gov (United States)

    Refat, Moamen S.; Sharshar, T.; Elsabawy, Khaled M.; Heiba, Zein K.

    2013-09-01

    Metal aspirinate complexes, M2(Asp)4, where M is Mg(II), Ca(II), Sr(II) or Ba(II) are formed by refluxed of aspirin (Asp) with divalent non-transition metal ions of group (II) and characterized by elemental analysis and spectroscopic measurements (infrared, electronic, 1H NMR, Raman, X-ray powder diffraction and scanning electron microscopy). Elemental analysis of the chelates suggests the stoichiometry is 1:2 (metal:ligand). Infrared spectra of the complexes agree with the coordination to the central metal atom through three donation sites of two oxygen atoms of bridge bidentate carboxylate group and oxygen atom of sbnd Cdbnd O of acetyl group. Infrared spectra coupled with the results of elemental analyzes suggested a distorted octahedral structure for the M(II) aspirinate complexes. Gamma irradiation was tested as a method for stabilization of aspirin as well as their complexes. The effect of gamma irradiation, with dose of 80 Gy, on the properties of aspirinate complexes was studied. The aspirinate chelates have been screened for their in vitro antibacterial activity against four bacteria, gram-positive (Bacillus subtilis and Staphylococcus aureus) and gram-negative (Escherichia coli and Pseudomonas aeruginosa) and two strains of fungus (Aspergillus flavus and Candida albicans). The metal chelates were shown to possess more antibacterial activity than the free aspirin chelate.

  19. Clinical Benefits of Memantine Treatment for Alzheimer's Disease in the Okayama Memantine Study II (OMS II).

    Science.gov (United States)

    Matsuzono, Kosuke; Yamashita, Toru; Ohta, Yasuyuki; Hishikawa, Nozomi; Koike, Makoto; Sato, Kota; Kono, Syoichiro; Deguchi, Kentaro; Nakano, Yumiko; Abe, Koji

    2015-01-01

    The clinical benefits of memantine, depending on the baseline cognitive and affective conditions in real world dementia clinics, have not been completely examined. We performed the "Okayama Memantine Study II (OMS II)" to retrospectively evaluate the clinical effects of memantine monotherapy (n = 38) in Alzheimer's disease (AD) patients using seven batteries to assess dementia at the baseline, at 3, 6, and 12 months. Additionally, we divided 163 AD patients treated with memantine into two subgroups depending on the baseline cognitive score of the Mini-Mental State Examination (MMSE): the MMSE OMS II showed that memantine monotherapy improved BPSD until 12 months. The higher baseline cognitive subgroup (MMSE ≥15) and the worse baseline BPSD subgroup were expected to show better effects with memantine.

  20. Studies of mn (ii) and ni (ii) complexes with schiff base derived from ...

    African Journals Online (AJOL)

    However, manganese(II) complex is insoluble in most organic solvents but soluble in dimethylsulphoxide (DMSO). The molar conductance of the complexes measured are, indicating their non-electrolytic nature. The potentiometric and spectrophotometric studies of the complex compounds revealed 1:1 metal to ligand ratio.

  1. Studies of Mn (II) and Ni (II) complexes with Schiff base derived from ...

    African Journals Online (AJOL)

    However, manganese(II) complex is insoluble in most organic solvents but soluble in dimethylsulphoxide (DMSO). The molar conductance of the complexes measured are low, indicating their non-electrolytic nature. The potentiometric and spectrophotometric studies of the complex compounds revealed 1:1 metal to ligand ...

  2. RESULTS OF ACCELERATED LIFE TESTING OF LCLS-II CAVITY TUNER MOTOR

    Energy Technology Data Exchange (ETDEWEB)

    Huque, Naeem [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Daly, Edward F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Pischalnikov, Yuriy [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2018-04-01

    An Accelerated Life Test (ALT) of the Phytron stepper motor used in the LCLS-II cavity tuner has been conducted at JLab. Since the motor will reside inside the cryomodule, any failure would lead to a very costly and arduous repair. As such, the motor was tested for the equivalent of 30 lifetimes before being approved for use in the production cryomodules. The 9-cell LCLS-II cavity is simulated by disc springs with an equivalent spring constant. Plots of the motor position vs. tuner position ' measured via an installed linear variable differential transformer (LVDT) ' are used to measure motor motion. The titanium spindle was inspected for loss of lubrication. The motor passed the ALT, and is set to be installed in the LCLS-II cryomodules.

  3. Status of the Warm Front End of PIP-II Injector Test

    Energy Technology Data Exchange (ETDEWEB)

    Shemyakin, Alexander [Fermilab; Alvarez, Matthew [Fermilab; Andrews, Richard [Fermilab; Baffes, Curtis [Fermilab; Carneiro, Jean-Paul [Fermilab; Chen, Alex [Fermilab; Derwent, Paul [Fermilab; Edelen, Jonathan [Fermilab; Frolov, Daniil [Fermilab; Hanna, Bruce [Fermilab; Prost, Lionel [Fermilab; Saewert, Gregory [Fermilab; Saini, Arun [Fermilab; Scarpine, Victor [Fermilab; Sista, V. Lalitha [Fermilab; Steimel, Jim [Fermilab; Sun, Ding [Fermilab; Warner, Arden [Fermilab

    2017-05-01

    The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW-compatible, pulsed H⁻ SRF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test is under construction. It includes a 10 mA DC, 30 keV H⁻ ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) that feeds the first of 2 cryomodules increasing the beam energy to about 25 MeV, and a High Energy Beam Transport section (HEBT) that takes the beam to a dump. The ion source, LEBT, RFQ, and initial version of the MEBT have been built, installed, and commissioned. This report presents the overall status of the warm front end.

  4. Pre-test evaluation of LLTR Series II Test A-6

    International Nuclear Information System (INIS)

    Knittle, D.

    1980-11-01

    Purpose of this report is to present pre-test predictions of pressure histories for the A6 test to be conducted in the Large Leak Test Facility (LLTF) at the Energy Technology Engineering Center. A6 is part of a test program being conducted to evaluate the effects of leaks produced by a double-ended guillotine rupture of a single tube. A6 will provide data on the CRBR prototypical double rupture disc performance

  5. Confinement studies in the TJ-II stellarator

    NARCIS (Netherlands)

    Alejaldre, C.; Alonso, J.; Almoguera, L.; Ascasibar, E.; Baciero, A.; Balbin, R.; Blaumoser, M.; Botija, J.; Branas, B.; De La Cal, E.; Cappa, A.; Carrasco, R.; Castejon, F.; Cepero, J. R.; Cremy, C.; Delgrado, J. M.; Doncel, J.; Dulya, C.; Estrada, T.; Fernandez, A.; Fuentes, C.; Garcia, A.; Garcia-Cortes, I.; Guasp, J.; Herranz, J.; Hidalgo, C.; Jimenez, J. A.; Kirpitchev, I.; Krivenski, V.; Labrador, I.; Lapayese, F.; Likin, K.; Linier, M.; Lopez-Fraguas, A.; Lopez-Sanchez, A.; de la Luna, E.; Martin, R.; Martinez, A.; Martinez-Laso, L.; Medrano, M.; Mendez, P.; McCarthy, K. J.; Medina, F.; van Milligen, B.; Ochando, M.; Pacios, L.; Pastor, I.; Pedrosa, M. A.; de la Pena, A.; Portas, A.; Qin, J.; Rodriguez-Rodrigo, L.; Salas, A.; Sanchez, E.; Sanchez, J.; Tabares, F.; Tafalla, D.; Tribaldos, V.; Vega, J.; Zurro, B.; Akulina, D.; Fedyanin, O. I.; Grebenshchikov, S.; Kharchev, N.; Meshcheryakov, A.; Sarksian, K. A.; Barth, R.; van Dijk, G.; van der Meiden, H.

    1999-01-01

    ECR (electron cyclotron resonance) heated plasmas have been studied in the low magnetic shear TJ-II stellarator (R = 1.5 m, a < 0.22 m, B = 1 T, f = 53.2 GHz, P-ECRH = 300 kW, power density = 1-25 W cm(-3)). Recent experiments have explored the flexibility of the TJ-II across a wide range of

  6. Synthesis, spectral characterization thermal stability, antimicrobial studies and biodegradation of starch–thiourea based biodegradable polymeric ligand and its coordination complexes with [Mn(II, Co(II, Ni(II, Cu(II, and Zn(II] metals

    Directory of Open Access Journals (Sweden)

    Nahid Nishat

    2016-09-01

    Full Text Available A biodegradable polymer was synthesized by the modification reaction of polymeric starch with thiourea which is further modified by transition metals, Mn(II, Co(II, Ni(II, Cu(II and Zn(II. All the polymeric compounds were characterized by (FT-IR spectroscopy, 1H NMR spectroscopy, 13C NMR spectroscopy, UV–visible spectra, magnetic moment measurements, thermogravimetric analysis (TGA and antibacterial activities. Polymer complexes of Mn(II, Co(II and Ni(II show octahedral geometry, while polymer complexes of Cu(II and Zn(II show square planar and tetrahedral geometry, respectively. The TGA revealed that all the polymer metal complexes are more thermally stable than their parental ligand. In addition, biodegradable studies of all the polymeric compounds were also carried out through ASTM-D-5338-93 standards of biodegradable polymers by CO2 evolution method which says that coordination decreases biodegradability. The antibacterial activity was screened with the agar well diffusion method against some selected microorganisms. Among all the complexes, the antibacterial activity of the Cu(II polymer–metal complex showed the highest zone of inhibition because of its higher stability constant.

  7. Blanket comparison and selection study. Volume II

    International Nuclear Information System (INIS)

    1983-10-01

    This volume contains extensive data for the following chapters: (1) solid breeder tritium recovery, (2) solid breeder blanket designs, (3) alternate blanket concept screening, and (4) safety analysis. The following appendices are also included: (1) blanket design guidelines, (2) power conversion systems, (3) helium-cooled, vanadium alloy structure blanket design, (4) high wall loading study, and (5) molten salt safety studies

  8. Major therapeutic effect of pentoxifylline-tocopherol association in the superficial radioinduced fibrosis: phase II test

    International Nuclear Information System (INIS)

    Delanian, S.; Balla-Mekias, S.; Maylin, C.; Lefaix, J.L.

    1997-01-01

    The association of pentoxifylline-tocopherol seems efficient in the reduction of the superficial human radioinduced fibrosis. This phase II invites to realize a randomized test and to a comparison with the results got with the dismutase superoxide. (N.C.)

  9. Potential safety enhancements to nuclear plant control: proof testing at EBR-II

    International Nuclear Information System (INIS)

    Lindsay, R.W.; Chisholm, G.H.

    1984-01-01

    Future changes in nuclear plant control and protective systems will reflect an evolutionary improvement through increased use of computers coupled with a better integration of man and machine. Before improvements can be accepted into the licensed commercial plant environment, significant testing must be accomplished to answer safety questions and to prove the worth of new ideas. The Experimental Breeder Reactor-II (EBR-II) is being used as a test-bed for both in-house development and testing for others in a DOE sponsored Man-Machine Integration program. The ultimate result of the development and testing would be a control system for which safety credit could be taken in the licensing process

  10. Conceptual design study on inertial confinement reactor ''SENRI-II''

    International Nuclear Information System (INIS)

    Nakamura, N.; Ouura, H.

    1983-01-01

    Design features of a laser fusion reactor concept SENRI-II are reviewed and discussed. A conceptual design study of the ICF reactor SENRI-II (an advanced design of SENRI-I) has been carried out over 2 years in the Research Committee of ICF Reactors, Institute of Laser Engineering, Osaka University. While the ICF reactor SENRI-I utilized a magnetic field to guide and control an inner liquid lithium flow, SENRI-II is designed to use porous metal as the liquid lithium flow guide. In the design of SENRI-II, a metal porous lithium blanket serves as the protection of a wall against fusion products and as wall per se. Because of the separation of these two functions, a high power density can be attained

  11. Synthesis, spectral, antitumor, antioxidant and antimicrobial studies on Cu(II), Ni(II) and Co(II) complexes of 4-[(1H-Benzoimidazol-2-ylimino)-methyl]-benzene-1,3-diol.

    Science.gov (United States)

    El-wakiel, Nadia; El-keiy, Mai; Gaber, Mohamed

    2015-08-05

    A new Schiff base of 2-aminobenzimidazole with 2,4-dihydroybezaldehyde (H₃L), and its Cu(II), Ni(II) and Co(II) complexes have been synthesized and characterized by elemental analyses, molar conductance, thermal analysis (TGA), inductive coupled plasma (ICP), magnetic moment measurements, IR, EI-mass, UV-Vis. and ESR spectral studies. On the basis of spectral studies and analytical data, it is evident that the Schiff base acts as dibasic tridentate ligand coordinating via deprotonated OH, NH and azomethine nitrogen atom. The results showed that Co(II) and Ni(II) complexes have tetrahedral structure while Cu(II) complexes has octahedral geometry. The kinetic and thermodynamic parameters of the thermal decomposition stages have been evaluated. The studied complexes were tested for their in vitro antimicrobial activities against some bacterial strains. The anticancer activity of the ligand and its metal complexes is evaluated against human liver Carcinoma (HEPG2) cell. These compounds exhibited a moderate and weak activity against the tested HEPG2 cell lines with IC₅₀ of 9.08, 18.2 and 19.7 μg/ml for ligand, Cu(II) and Ni(II) complexes, respectively. In vitro antioxidant activity of the newly synthesized compounds has also been evaluated. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Full-scale Mark II CRT program: dynamic response evaluation test of pressure transducers

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Namatame, Ken; Takeshita, Isao; Shiba, Masayoshi

    1982-12-01

    A dynamic response evaluation test of pressure transducers was conducted in support of the JAERI Full-Scale Mark II CRT (Containment Response Test) Program. The test results indicated that certain of the cavity-type transducers used in the early blowdown test had undesirable response characteristics. The transducer mounting scheme was modified to avoid trapping of air bubbles in the pressure transmission tubing attached to the transducers. The dynamic response of the modified transducers was acceptable within the frequency range of 200 Hz. (author)

  13. Organisational justice and markers of inflammation: the Whitehall II study.

    Science.gov (United States)

    Elovainio, Marko; Ferrie, Jane E; Singh-Manoux, Archana; Gimeno, David; De Vogli, Roberto; Shipley, Martin; Vahtera, Jussi; Brunner, Eric; Marmot, Michael G; Kivimäki, Mika

    2010-02-01

    Low organisational justice has been shown to be associated with increased risk of various health problems, but the underlying mechanisms remain unclear. We tested whether organisational injustice contributes to chronic inflammation in a population of middle-aged men and women. This prospective cohort study uses data from 3205 men and 1204 women aged 35-55 years at entry into the Whitehall II study (phase 1, 1985-1988). Organisational justice perceptions were assessed at phase 1 and phase 2 (1989-1990) and circulating inflammatory markers C-reactive protein (CRP) and interleukin (IL)-6 at phase 3 (1991-1993) and phase 7 (2003-2004). In men, low organisational justice was associated with increased CRP levels at both follow-ups (phase 3 and 7) and increased IL-6 at the second follow-up (phase 7). The long term (phase 7) associations were largely independent of covariates, such as age, employment grade, body mass index and depressive symptoms. In women, no relationship was found between organisational justice and CRP or IL-6. This study suggests that organisational injustice is associated with increased long-term levels of inflammatory markers among men.

  14. Thermodynamic study of selected monoterpenes II

    International Nuclear Information System (INIS)

    Štejfa, Vojtěch; Fulem, Michal; Růžička, Květoslav; Červinka, Ctirad

    2014-01-01

    Highlights: • (−)-Borneol, (−)-camphor, (±)-camphene, and (+)-fenchone were studied. • New thermodynamic data were measured and calculated. • Most of thermodynamic data are reported for the first time. - Abstract: A thermodynamic study of selected monoterpenes, (−)-borneol, (−)-camphor, (±)-camphene, and (+)-fenchone is presented in this work. The vapor pressure measurements were performed using the static method over the environmentally important temperature range from (238 to 308) K. Heat capacities of condensed phases were measured by Tian–Calvet calorimetry in the temperature interval from (258 to 355) K. The phase behavior was investigated by differential scanning calorimetry (DSC) from subambient temperatures up to the fusion temperatures. The thermodynamic properties in the ideal-gas state were calculated by combining statistical thermodynamic and density functional theory (DFT) calculations. Calculated ideal-gas heat capacities and experimental data for vapor pressures and condensed phase heat capacities were treated simultaneously to obtain a consistent thermodynamic description

  15. Elliptical cross section fuel rod study II

    International Nuclear Information System (INIS)

    Taboada, H.; Marajofsky, A.

    1996-01-01

    In this paper it is continued the behavior analysis and comparison between cylindrical fuel rods of circular and elliptical cross sections. Taking into account the accepted models in the literature, the fission gas swelling and release were studied. An analytical comparison between both kinds of rod reveals a sensible gas release reduction in the elliptical case, a 50% swelling reduction due to intragranular bubble coalescence mechanism and an important swelling increase due to migration bubble mechanism. From the safety operation point of view, for the same linear power, an elliptical cross section rod is favored by lower central temperatures, lower gas release rates, greater gas store in ceramic matrix and lower stored energy rates. (author). 6 refs., 8 figs., 1 tab

  16. [Vision test program for ophthalmologists on Apple II, IIe and IIc computers].

    Science.gov (United States)

    Huber, C

    1985-03-01

    A microcomputer program for the Apple II family of computers on a monochrome and a color screen is described. The program draws most of the tests used by ophthalmologists, and is offered as an alternative to a projector system. One advantage of the electronic generation of drawings is that true random orientation of Pflueger's E is possible. Tests are included for visual acuity (Pflueger's E, Landolt rings, numbers and children's drawings). Colored tests include a duochrome test, simple color vision tests, a fixation help with a musical background, a cobalt blue test and a Worth figure. In the astigmatic dial a mobile pointer helps to determine the axis. New tests can be programmed by the user and exchanged on disks among collageues.

  17. Operational-safety advantages of LMFBR's: the EBR-II experience and testing program

    International Nuclear Information System (INIS)

    Sackett, J.I.; Lindsay, R.W.; Golden, G.H.

    1982-01-01

    LMFBR's contain many inherent characteristics that simplify control and improve operating safety and reliability. The EBR-II design is such that good advantage was taken of these characteristics, resulting in a vary favorable operating history and allowing for a program of off-normal testing to further demonstrate the safe response of LMFBR's to upsets. The experience already gained, and that expected from the future testing program, will contribute to further development of design and safety criteria for LMFBR's. Inherently safe characteristics are emphasized and include natural convective flow for decay heat removal, minimal need for emergency power and a large negative reactivity feedback coefficient. These characteristics at EBR-II allow for ready application of computer diagnosis and control to demonstrate their effectiveness in response to simulated plant accidents. This latter testing objective is an important part in improvements in the man-machine interface

  18. Justice at work and metabolic syndrome: the Whitehall II study.

    Science.gov (United States)

    Gimeno, David; Tabák, Adám G; Ferrie, Jane E; Shipley, Martin J; De Vogli, Roberto; Elovainio, Marko; Vahtera, Jussi; Marmot, Michael G; Kivimäki, Mika

    2010-04-01

    Growing evidence shows that high levels of justice are beneficial for employee health, although biological mechanisms underlying this association are yet to be clarified. We aim to test whether high justice at work protects against metabolic syndrome. A prospective cohort study of 20 civil service departments in London (the Whitehall II study) including 6123 male and female British civil servants aged 35-55 years without prevalent coronary heart disease at baseline (1985-1990). Perceived justice at work was determined by means of questionnaire on two occasions between 1985 and 1990. Follow-up for metabolic syndrome and its components occurring from 1990 to 2004 was based on clinical assessments on three occasions over more than 18 years. Cox proportional hazard models adjusted for age, ethnicity and employment grade showed that men who experienced a high level of justice at work had a lower risk of incident metabolic syndrome than employees with a low level of justice (HR 0.75; 95% CI 0.63 to 0.89). There was little evidence of an association between organisational justice and metabolic syndrome or its components in women (HR 0.88; 95% CI 0.67 to 1.17). Our prospective findings provide evidence of an association between high levels of justice at work and the development of metabolic syndrome in men.

  19. Radioactivity studies. Progress report. Volume II

    International Nuclear Information System (INIS)

    Cohen, N.

    1981-09-01

    The metabolism of 243 244 Cm in nine adult female baboons following intravenous injection was studied. Curium-243,244 was administered as a single injection of curium citrate in dosages of 0.053 to 0.220 μCi/kg. The behavior of 243 244 Cm at these low dosages was quantitated by external whole-body and partial-body counting, bioassay of blood, urine and feces samples, liver biopsies, and post-mortem tissues analysis. Curium-243,244 rapidly passed from the blood to other tissues. At 1 and 24 h after injection, the amounts circulating were 10% and 1%, respectively. At 24 h after injection 70% of the 243 244 Cm was located within soft tissues, probably associated with extracellular fluid; the liver alone contained 32% of the injected activity. During the first weeks the content of 243 244 Cm in soft tissues decreased sharply. As time progressed, significant deposition was noted in the liver and the skeleton. Approximately 20% of the injected activity was in the liver at 1 month with a 40 day half-time. The skeleton reached a maximum burden of 57% by 100 days; the half-time observed in bone was 4 to 16 y. During the first 24 h, 10% of the injected activity appeared in the urine decreasing to 0.1%/day at 30 days and 0.01%/day at 200 days. Fecal excretion increased reaching a maximum level at four weeks. The amount of 243 244 Cm excreted in the feces during the initial 4 to 5 months (approx. 20%) and the rate of elimination in the feces after the first month paralleled the retention in the liver indicating an hepatic-biliary-fecal pathway. A model illustrating the interaction of seven internal compartments with respect to the translocation kinetics of 243 244 Cm was derived based upon this data. Solutions of the model were derived for two specific time-related exposures

  20. Test program element II blanket and shield thermal-hydraulic and thermomechanical testing, experimental facility survey

    International Nuclear Information System (INIS)

    Ware, A.G.; Longhurst, G.R.

    1981-12-01

    This report presents results of a survey conducted by EG and G Idaho to determine facilities available to conduct thermal-hydraulic and thermomechanical testing for the Department of Energy Office of Fusion Energy First Wall/Blanket/Shield Engineering Test Program. In response to EG and G queries, twelve organizations (in addition to EG and G and General Atomic) expressed interest in providing experimental facilities. A variety of methods of supplying heat is available

  1. Test program element II blanket and shield thermal-hydraulic and thermomechanical testing, experimental facility survey

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.G.; Longhurst, G.R.

    1981-12-01

    This report presents results of a survey conducted by EG and G Idaho to determine facilities available to conduct thermal-hydraulic and thermomechanical testing for the Department of Energy Office of Fusion Energy First Wall/Blanket/Shield Engineering Test Program. In response to EG and G queries, twelve organizations (in addition to EG and G and General Atomic) expressed interest in providing experimental facilities. A variety of methods of supplying heat is available.

  2. EFFECT OF CADMIUM(II) ON FREE RADICALS IN DOPA-MELANIN TESTED BY EPR SPECTROSCOPY.

    Science.gov (United States)

    Zdybel, Magdalena; Pilawa, Barbara; Chodurek, Ewa

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy may be applied to examine interactions of melanin with metal ions and drugs. In this work EPR method was used to examination of changes in free radical system of DOPA-melanin--the model eumelanin after complexing with diamagnetic cadmium(II) ions. Cadmium(II) may affect free radicals in melanin and drugs binding by this polymer, so the knowledge of modification of properties and free radical concentration in melanin is important to pharmacy. The effect of cadmium(II) in different concentrations on free radicals in DOPA-melanin was determined. EPR spectra of DOPA-melanin, and DOPA-melanin complexes with cadmium(II) were measured by an X-band (9.3 GHz) EPR spectrometer produced by Radiopan (Poznań, Poland) and the Rapid Scan Unit from Jagmar (Krak6w, Poland). The DOPA (3,4-dihydroxyphenylalanine) to metal ions molar ratios in the reaction mixtures were 2:1, 1:1, and 1: 2. High concentrations of o-semiquinone (g ~2.0040) free radicals (~10(21)-10(22) spin/g) characterize DOPA-melanin and its complexes with cadmium(II). Formation of melanin complexes with cadmium(II) increase free radical concentration in DOPA-melanin. The highest free radical concentration was obtained for DOPA-melanin-cadmium(II) (1:1) complexes. Broad EPR lines with linewidths: 0.37-0.73 mT, were measured. Linewidths increase after binding of cadmium(II) to melanin. Changes of integral intensities and linewidths with increasing microwave power indicate the homogeneous broadening of EPR lines, independently on the metal ion concentration. Slow spin-lattice relaxation processes existed in all the tested samples, their EPR lines saturated at low microwave powers. Cadmium(II) causes fastening of spin-lattice relaxation processes in DOPA-melanin. The EPR results bring to light the effect of cadmium(II) on free radicals in melanin, and probably as the consequence on drug binding to eumelanin.

  3. PISC II: parametric studies. The purpose of the PISC II parametric studies programme

    International Nuclear Information System (INIS)

    Crutzen, S.

    1989-09-01

    The results of the PISC I round robin test of the ASME type procedure showed a very large dispersion. The amplitude of response of all defects varied very much among the teams from the 27 laboratories considered for the evaluation of results. Scatter on detection and sizing in PISC I was such that discussions started on the reasons for such a phenomenon when exactly the same procedure was used by all teams. The observation of two teams' results (JRC Ispra and ENEL Piacenza, Italy) induced the NDE Ispra laboratories to insist on the possible importance of equipment characteristics. All PISC members insisted on specific studies of the influence of defect characteristics as well as the role of cladding. These three chapters were the leading PIS laboratory exercises called Parametric Studies

  4. Synthesis, characterization and biological studies of metal complexes of Co (II), Ni (II), Cu (II), Zn (II) with sulphadimidine-benzylidene

    International Nuclear Information System (INIS)

    Tahira, F.; Imran, M.; Iqbal, J.

    2009-01-01

    Some novel complexes of Co (II), Ni (II), Cu (II), and Zn (II) have been synthesized with a Schiff base ligand derived from sulphadimidine and benzaldehyde. The structural features of the complexes have been determined by elemental analysis, magnetic susceptibility, conductance measurement, UV/ Vis. and infrared spectroscopy. IR studies revealed that the Schiff base ligand Sulphadimidine-benzylidene has monoanionic bidendate nature and coordinate with metal ions through nitrogen atom of azomethine (>C = N) and deprotonated -NH group. All the complexes were assigned octahedral geometry on the basis of magnetic moment and electronic spectroscopic data. Low value of conductance supports their non-electrolytic nature. The ligand, as well as its complexes were checked for their in vitro antimicrobial activities against two gram positive bacterial strains, Bacillus subtillus. Staphylococcus aureus and one gram negative Salmonella typhae and five fungal strains, Nigrospora oryzae, Curvularia lunata, Drechslera rostrata, Aspergillus niger and Candida olbicans by disc diffusion method and agar plate technique, respectively. Both the antibacterial and antitungal activities of the synthesized metal complexes were found to be more as compared to parent drug and uncomplexed ligand. All the complexes contain coordinated water, which is lost at 141-160 degree C. (author)

  5. A retrospective study of Class II mixed-dentition treatment.

    Science.gov (United States)

    Oh, Heesoo; Baumrind, Sheldon; Korn, Edward L; Dugoni, Steven; Boero, Roger; Aubert, Maryse; Boyd, Robert

    2017-01-01

    To consider the effectiveness of early treatment using one mixed-dentition approach to the correction of moderate and severe Class II malocclusions. Three groups of Class II subjects were included in this retrospective study: an early treatment (EarlyTx) group that first presented at age 7 to 9.5 years (n = 54), a late treatment (LateTx) group whose first orthodontic visit occurred between ages 12 and 15 (n = 58), and an untreated Class II (UnTx) group to assess the pretreatment comparability of the two treated groups (n = 51). Thirteen conventional cephalometric measurements were reported for each group and Class II molar severity was measured on the study casts of the EarlyTx and LateTx groups. Successful Class II correction was observed in approximately three quarters of both the EarlyTx group and the LateTx group at the end of treatment. EarlyTx patients had fewer permanent teeth extracted than did the LateTx patients (5.6% vs 37.9%, P < .001) and spent less time in full-bonded appliance therapy in the permanent dentition than did LateTx patients (1.7 ± 0.8 vs 2.6 ± 0.7years, P < .001). When supervision time is included, the EarlyTx group had longer total treatment time and averaged more visits than did the LateTx group (53.1 ± 18. 8 vs 33.7 ± 8.3, P < .0001). Fifty-five percent of the LateTx extraction cases involved removal of the maxillary first premolars only and were finished in a Class II molar relationship. EarlyTx comprehensive mixed-dentition treatment was an effective modality for early correction of Class II malocclusions.

  6. PULSE COMBUSTOR DESIGN QUALIFICATION TEST AND CLEAN COAL FEEDSTOCK TEST - VOLUME I AND VOLUME II; FINAL

    International Nuclear Information System (INIS)

    Unknown

    2002-01-01

    For this Cooperative Agreement, the pulse heater module is the technology envelope for an indirectly heated steam reformer. The field of use of the steam reformer pursuant to this Cooperative Agreement with DOE is for the processing of sub-bituminous coals and lignite. The main focus is the mild gasification of such coals for the generation of both fuel gas and char-for the steel industry is the main focus. An alternate market application for the substitution of metallurgical coke is also presented. This project was devoted to qualification of a 253-tube pulse heater module. This module was designed, fabricated, installed, instrumented and tested in a fluidized bed test facility. Several test campaigns were conducted. This larger heater is a 3.5 times scale-up of the previous pulse heaters that had 72 tubes each. The smaller heater has been part of previous pilot field testing of the steam reformer at New Bern, North Carolina. The project also included collection and reduction of mild gasification process data from operation of the process development unit (PDU). The operation of the PDU was aimed at conditions required to produce char (and gas) for the Northshore Steel Operations. Northshore Steel supplied the coal for the process unit tests

  7. PULSE COMBUSTOR DESIGN QUALIFICATION TEST AND CLEAN COAL FEEDSTOCK TEST - VOLUME I AND VOLUME II

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2002-02-08

    For this Cooperative Agreement, the pulse heater module is the technology envelope for an indirectly heated steam reformer. The field of use of the steam reformer pursuant to this Cooperative Agreement with DOE is for the processing of sub-bituminous coals and lignite. The main focus is the mild gasification of such coals for the generation of both fuel gas and char--for the steel industry is the main focus. An alternate market application for the substitution of metallurgical coke is also presented. This project was devoted to qualification of a 253-tube pulse heater module. This module was designed, fabricated, installed, instrumented and tested in a fluidized bed test facility. Several test campaigns were conducted. This larger heater is a 3.5 times scale-up of the previous pulse heaters that had 72 tubes each. The smaller heater has been part of previous pilot field testing of the steam reformer at New Bern, North Carolina. The project also included collection and reduction of mild gasification process data from operation of the process development unit (PDU). The operation of the PDU was aimed at conditions required to produce char (and gas) for the Northshore Steel Operations. Northshore Steel supplied the coal for the process unit tests.

  8. potentiometric studies of the complexes formed by copper (ii)

    African Journals Online (AJOL)

    MBI

    The overall stability constants of copper (II) and zinc (II) ions with some polar ... The average number of coordinated amino acids to the copper (II) and zinc (II) ions .... of chelated rings (Yamuchi and Odani, 1996). ... Synthesis and techniques in.

  9. Silk I and Silk II studied by fast scanning calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cebe, Peggy; Partlow, Benjamin P.; Kaplan, David L.; Wurm, Andreas; Zhuravlev, Evgeny; Schick, Christoph

    2017-06-01

    Using fast scanning calorimetry (FSC), we investigated the glass transition and crystal melting of samples of B. mori silk fibroin containing Silk I and/or Silk II crystals. Due to the very short residence times at high temperatures during such measurements, thermal decomposition of silk protein can be significantly suppressed. FSC was performed at 2000 K/s using the Mettler Flash DSC1 on fibroin films with masses around 130–270 ng. Films were prepared with different crystalline fractions (ranging from 0.26 to 0.50) and with different crystal structures (Silk I, Silk II, or mixed) by varying the processing conditions. These included water annealing at different temperatures, exposure to 50% MeOH in water, or autoclaving. The resulting crystal structure was examined using wide angle X-ray scattering. Degree of crystallinity was evaluated from Fourier transform infrared (FTIR) spectroscopy and from analysis of the heat capacity increment at the glass transition temperature. Silk fibroin films prepared by water annealing at 25 °C were the least crystalline and had Silk I structure. FTIR and FSC studies showed that films prepared by autoclaving or 50% MeOH exposure were the most crystalline and had Silk II structure. Intermediate crystalline fraction and mixed Silk I/Silk II structures were found in films prepared by water annealing at 37 °C. FSC results indicate that Silk II crystals exhibit endotherms of narrower width and have higher mean melting temperature Tm(II) = 351 ± 2.6 °C, compared to Silk I crystals which melt at Tm(I) = 292 ± 3.8 °C. Films containing mixed Silk I/Silk II structure showed two clearly separated endothermic peaks. Evidence suggests that the two types of crystals melt separately and do not thermally interconvert on the extremely short time scale (0.065 s between onset and end of melting) of the FSC experiment.

  10. Upgrade of the SLAC SLED II Pulse Compression System Based on Recent High Power Tests

    International Nuclear Information System (INIS)

    Vlieks, A.E.; Fowkes, W.R.; Loewen, R.J.; Tantawi, S.G.

    2011-01-01

    In the Next Linear Collider (NLC) it is expected that the high power rf components be able to handle peak power levels in excess of 400 MW. We present recent results of high power tests designed to investigate the RF breakdown limits of the X-band pulse compression system used at SLAC. (SLED-II). Results of these tests show that both the TE 01 -TE 10 mode converter and the 4-port hybrid have a maximum useful power limit of 220-250 MW. Based on these tests, modifications of these components have been undertaken to improve their peak field handling capability. Results of these modifications will be presented. As part of an international effort to develop a new 0.5-1.5 TeV electron-positron linear collider for the 21st century, SLAC has been working towards a design, referred to as 'The Next Linear Collider' (NLC), which will operate at 11.424 GHz and utilize 50-75 MW klystrons as rf power sources. One of the major challenges in this design, or any other design, is how to generate and efficiently transport extremely high rf power from a source to an accelerator structure. SLAC has been investigating various methods of 'pulse compressing' a relatively wide rf pulse ((ge) 1 μs) from a klystron into a narrower, but more intense, pulse. Currently a SLED-II pulse compression scheme is being used at SLAC in the NLC Test Accelerator (NLCTA) and in the Accelerator Structures Test Area (ASTA) to provide high rf power for accelerator and component testing. In ASTA, a 1.05 μs pulse from a 50 MW klystron was successfully pulse compressed to 205 MW with a pulse width of 150 ns. Since operation in NLC will require generating and transporting rf power in excess of 400 MW it was decided to test the breakdown limits of the SLED-II rf components in ASTA with rf power up to the maximum available of 400 MW. This required the combining of power from two 50 MW klystrons and feeding the summed power into the SLED-II pulse compressor. Results from this experiment demonstrated that two of

  11. SASSYS-1 computer code verification with EBR-II test data

    International Nuclear Information System (INIS)

    Warinner, D.K.; Dunn, F.E.

    1985-01-01

    The EBR-II natural circulation experiment, XX08 Test 8A, is simulated with the SASSYS-1 computer code and the results for the latter are compared with published data taken during the transient at selected points in the core. The SASSYS-1 results provide transient temperature and flow responses for all points of interest simultaneously during one run, once such basic parameters as pipe sizes, initial core flows, and elevations are specified. The SASSYS-1 simulation results for the EBR-II experiment XX08 Test 8A, conducted in March 1979, are within the published plant data uncertainties and, thereby, serve as a partial verification/validation of the SASSYS-1 code

  12. Cosmic ray test of the Belle II z-vertex trigger

    Energy Technology Data Exchange (ETDEWEB)

    Neuhaus, Sara; Skambraks, Sebastian [Technische Universitaet Muenchen (Germany); Chen, Yang; Kiesling, Christian [Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2016-07-01

    The z-vertex trigger is part of the first level track trigger in the Belle II experiment. Its task is the rejection of tracks not coming from the interaction region, suppressing a large part of the machine background. Therefore the z-vertex trigger allows to relax other track trigger conditions and thus strongly increases the efficiency for channels with low track multiplicity (e.g. tau pair production). The track trigger works in several steps, first combining hits to track segments, followed by a 2D track finding in the transverse plane and finally the 3D reconstruction. Our method employs neural networks to estimate the z-vertex without explicit track reconstruction. For the first real test with cosmic rays special neural networks have been prepared. Although the track shape in the cosmic test is different than in the Belle II experiment, the neural networks require only a retraining with an appropriate data set to adapt to the new geometry.

  13. ENRAF Series 854 Advanced Technology Gauge (ATG) with SPU II card for Leak Detector Use Acceptance Test Procedure

    International Nuclear Information System (INIS)

    SMITH, S.G.

    1999-01-01

    The following Acceptance Test Procedure was written to test the ENRAF series 854 ATG with SPU II card prior to installation in the Tank Farms. The procedure sets various parameters and verifies the gauge and alarms functionality

  14. A Statistical Study of Interplanetary Type II Bursts: STEREO Observations

    Science.gov (United States)

    Krupar, V.; Eastwood, J. P.; Magdalenic, J.; Gopalswamy, N.; Kruparova, O.; Szabo, A.

    2017-12-01

    Coronal mass ejections (CMEs) are the primary cause of the most severe and disruptive space weather events such as solar energetic particle (SEP) events and geomagnetic storms at Earth. Interplanetary type II bursts are generated via the plasma emission mechanism by energetic electrons accelerated at CME-driven shock waves and hence identify CMEs that potentially cause space weather impact. As CMEs propagate outward from the Sun, radio emissions are generated at progressively at lower frequencies corresponding to a decreasing ambient solar wind plasma density. We have performed a statistical study of 153 interplanetary type II bursts observed by the two STEREO spacecraft between March 2008 and August 2014. These events have been correlated with manually-identified CMEs contained in the Heliospheric Cataloguing, Analysis and Techniques Service (HELCATS) catalogue. Our results confirm that faster CMEs are more likely to produce interplanetary type II radio bursts. We have compared observed frequency drifts with white-light observations to estimate angular deviations of type II burst propagation directions from radial. We have found that interplanetary type II bursts preferably arise from CME flanks. Finally, we discuss a visibility of radio emissions in relation to the CME propagation direction.

  15. Ground testing and simulation. II - Aerodynamic testing and simulation: Saving lives, time, and money

    Science.gov (United States)

    Dayman, B., Jr.; Fiore, A. W.

    1974-01-01

    The present work discusses in general terms the various kinds of ground facilities, in particular, wind tunnels, which support aerodynamic testing. Since not all flight parameters can be simulated simultaneously, an important problem consists in matching parameters. It is pointed out that there is a lack of wind tunnels for a complete Reynolds-number simulation. Using a computer to simulate flow fields can result in considerable reduction of wind-tunnel hours required to develop a given flight vehicle.

  16. Confinement studies in the TJ-II stellarator

    International Nuclear Information System (INIS)

    Alejaldre, C.; Alonso, J.; Almoguera, L.; Ascasibar, E.; Baciero, A.; Balbin, R.; Blaumoser, M.; Botija, J.; Branas, B.; Cal, E. de la; Cappa, A.; Carrasco, R.; Castejon, F.; Cepero, J.R.; Cremy, C.; Delgado, J.M.; Doncel, J.; Dulya, C.; Estrada, T.; Fernandez, A.; Fuentes, C.; Garcia, A.; Garcia-Cortes, I.; Guasp, J.; Herranz, J.; Hidalgo, C.; Jimenez, J.A.; Kirpitchev, I.; Krivenski, V.; Labrador, I.; Lapayese, F.; Likin, K.; Linier, M.; Lopez-Fraguas, A.; Lopez-Sanchez, A.; Luna, E. de la; Martin, R.; Martinez, A.; Martinez-Laso, L.; Medrano, M.; Mendez, P.; McCarthy, K.J.; Medina, F.; Milligen, B. van; Ochando, M.; Pacios, L.; Pastor, I.; Pedrosa, M.A.; Pena, A. de la; Portas, A.; Qin, J.; Rodriguez-Rodrigo, L.; Salas, A.; Sanchez, E.; Sanchez, J.; Tabares, F.; Tafalla, D.; Tribaldos, V.; Vega, J.; Zurro, B.; Akulina, D.; Fedyanin, O.I.; Grebenshchikov, S.; Kharchev, N.; Meshcheryakov, A.; Sarksian, K.A.; Barth, R.; Dijk, G. van; Meiden, H. van der

    1999-01-01

    ECR (electron cyclotron resonance) heated plasmas have been studied in the low magnetic shear TJ-II stellarator (R = 1.5 m, a ECRH = 300 kW, power density = 1-25 W cm -3 ). Recent experiments have explored the flexibility of the TJ-II across a wide range of plasma volumes with different rotational transforms and rational surface densities. In this paper, the main results of this campaign are presented and, in particular, the influence of iota and rational surfaces on plasma profiles is discussed. (author)

  17. Development of metal fuel and study of construction materials (I-IV), Part V, Vol. II, Project of the device for irradiation of metal uranium in the reactor; 2. Construction of the loop for uranium radiation creep testing

    International Nuclear Information System (INIS)

    Mihajlovic, A.; Pavlovic, A.

    1965-11-01

    This volume includes the design description for construction of the loop for testing uranium radiation creep. It covers the following: construction of the loop head, protection closure; system for pressure regulation and uranium temperature regulation; system for recording samples dilatation and temperature. Testing of components and the loop on the whole is described as well as the safety reports

  18. Advances in prenatal screening for Down syndrome: II first trimester testing, integrated testing, and future directions.

    Science.gov (United States)

    Benn, Peter A

    2002-10-01

    The acceptability of prenatal screening and diagnosis of Down syndrome is dependent, in part, on the gestational age at which the testing is offered. First trimester screening could be advantageous if it has sufficient efficacy and can be effectively delivered. Two first trimester maternal serum screening markers, pregnancy-associated plasma protein-A (PAPP-A) and free beta-human chorionic gonadotropin (beta-hCG), are useful for identifying women at increased risk for fetal Down syndrome. In addition, measurement of an enlarged thickness of the subcutaneous fluid-filled space at the back of the neck of the developing fetus (referred to as nuchal translucency or NT) has been demonstrated to be an indicator for these high-risk pregnancies. When these three parameters are combined, estimates for Down syndrome efficacy exceed those currently attainable in the second trimester. Women who are screen-positive in the first trimester can elect to receive cytogenetic testing of a chorionic villus biopsy. The first trimester tests could also, theoretically, be combined with the second trimester maternal serum screening tests (integrated screening) to obtain even higher levels of efficacy. There are, however, several practical limitations to first trimester and integrated screening. These include scheduling of testing within relatively narrow gestational age intervals, availability of appropriately trained ultrasonographers for NT measurement, risks associated with chorionic villus biopsy, and costs. There is also increasing evidence that an enlarged NT measurement is indicative of a high risk for spontaneous abortion and for fetal abnormalities that are not detectable by cytogenetic analysis. Women whose fetuses show enlarged NT, therefore, need first trimester counseling regarding their Down syndrome risks and the possibility of other adverse pregnancy outcomes. Follow-up ultrasound and fetal echocardiography in the second trimester are also indicated. First trimester

  19. Adsorption dynamics and equilibrium studies of Zn (II)

    Indian Academy of Sciences (India)

    Batch equilibration studies are conducted to determine the nature of adsorption of zinc (II) over chitosan. The factors affecting the adsorption process like particle size, contact time, dosage, pH, effects of chloride and nitrate are identified. The influence of temperature and co-ions on the adsorption process is verified.

  20. 94 STUDIES ON DOG POPULATION IN MAKURDI, NIGERIA (II): A ...

    African Journals Online (AJOL)

    STUDIES ON DOG POPULATION IN MAKURDI, NIGERIA (II): A SURVEY OF ... only 5.2% mentioned tick infestation as potential health risk to dogs and humans. Bathing dogs with brush ... as pets and/or security alert; this has consequently ...

  1. Thermal Decompositon Studies Of Pre-Irradiated Nickel (II) Azides ...

    African Journals Online (AJOL)

    The effect of pre-irradiation on the thermal decomposition of three samples of nickel (II) azide was studied. It was found that the rates of thermal decomposition of Ni(OH)N3 increased substantially with increase in pre-irradiation dosage. The initial reaction rates change from time-dependant nucleation law for the unirradiated ...

  2. Caelyx (TM) in malignant mesothelioma : A phase II EORTC study

    NARCIS (Netherlands)

    Baas, P; van Meerbeeck, J; Groen, H; Schouwink, H; Burgers, S; Daamen, S; Giaccone, G

    Background: The use of doxorubicin has shown some activity in malignant mesothelioma but prolonged administration is hampered by cardiotoxicity. Caelyx(TM), a new liposomal and pegylated form of doxorubicin has shown a better pharmacokinetic and toxic profile then doxorubicin. In a phase II study,

  3. Adsorption dynamics and equilibrium studies of Zn (II) onto chitosan

    Indian Academy of Sciences (India)

    Unknown

    Adsorption dynamics and equilibrium studies of Zn (II) onto chitosan. G KARTHIKEYAN*, K ANBALAGAN and N MUTHULAKSHMI ANDAL. Department of Chemistry, Gandhigram Rural Institute – Deemed University, Gandhigram 624 302, India e-mail: drg_karthikeyan@rediffmail.com. MS received 3 June 2003; revised 12 ...

  4. Final report of the Buffer Mass Test. Volume II: test results

    International Nuclear Information System (INIS)

    Pusch, R.; Boerjesson, L.; Ramqvist, G.

    1985-08-01

    The evaluation of the Buffer Mass Test mainly concerned the heating of the bentonite/rock system that simulated hot canisters in deposition holes, the swelling and swelling pressure of the expanding bentonite in the heater holes, and the water uptake of the bentonite in the holes as well as in the tunnel backfill. These processes had been predicted on the basis of laboratory-derived data and FEM calculations with due consideration of the actual geometry. The recorded temperatures of the bentonite and surrounding rock were found to be below the maximum temperature that had been set, but higher than the expected values in the initial period of testing. The heater surface temperatures dropped in the course of the tests due to the uptake of water from the rock even in the driest hole which was located in almost fracture-free rock. The water uptake in the highly compacted bentonite in the heater holes was manifested by a successively increased swelling pressure at the bentonite/rock interface. It was rather uniformly distributed over this interface and reached a maximum value of about 10 MPa. The water content determination confirmed that water had been absorbed by the bentonite from the rock even in the driest holes where the counteracting thermal gradient was rather high. In the wettest holes the saturation became almost complete and a high degree of saturation was also observed in the tunnel backfill. Both in the heater holes and the tunnel, the moistening was found to be very uniform along the periphery, which is at least partly explained by the self-sealing ability of bentonite buffer materials. A general conclusion is that the involved physical processes are well understood and that the ultimate physical state of the buffer materials under repository conditions can be safely predicted. With 15 refs. (Author)

  5. Studying a disease with no home - lessons in trial recruitment from the PATCH II study

    Directory of Open Access Journals (Sweden)

    Thomas Kim S

    2010-03-01

    Full Text Available Abstract Background Cellulitis is a very common condition that often recurs. The PATCH II study was designed to explore the possibility of preventing future episodes of cellulitis, with resultant cost savings for the NHS. This was the first trial to be undertaken by the UK Dermatology Clinical Trials Network. As such, it was the first to test a recruitment model that involved many busy clinicians each contributing just a few patients. Methods A double-blind randomised controlled trial comparing prophylactic antibiotics (penicillin V with placebo tablets, for the prevention of repeat episodes of cellulitis of the leg. Primary outcome was time to subsequent recurrence of cellulitis. Results The PATCH II study was closed to recruitment having enrolled 123 participants from a target of 400. Whilst the recruitment period was extended by 12 months, it was not possible to continue beyond this point without additional funds. Many factors contributed to poor recruitment: (i changes in hospital policy and the introduction of community-based intravenous teams resulted in fewer cellulitis patients being admitted to hospital; ii those who were admitted were seen by many different specialties, making it difficult for a network of dermatology clinicians to identify suitable participants; and iii funding for research staff was limited to a trial manager and a trial administrator at the co-ordinating centre. With no dedicated research nurses at the recruiting centres, it was extremely difficult to maintain momentum and interest in the study. Attempts to boost recruitment by providing some financial support for principal investigators to employ local research staff was of limited success. Discussion The model of a network of busy NHS clinicians all recruiting a few patients into large clinical studies requires further testing. It did not work very well for PATCH II, but this was probably because patients were not routinely seen by dermatologists, and recruitment

  6. Design of a high-power test model of the PEP-II rf cavity

    International Nuclear Information System (INIS)

    Schwarz, H.D.; Bell, R.A.; Hodgson, J.A.

    1993-05-01

    The design of a normal-conducting high-power test cavity (HPTC) for PEP-II is described. The cavity includes HOM loading waveguides and provisions for testing two alternate input coupling schemes. 3-D electromagnetic field simulations provided input information for the surface power deposition. Finite element codes were utilized for thermal and stress analyses of the cavity to arrive at a suitable mechanical design capable of handling the high power dissipation. The mechanical design approach with emphasis on the cooling channel layout and mechanical stress reduction is described

  7. A Tool for Predicting Regulatory Approval After Phase II Testing of New Oncology Compounds.

    Science.gov (United States)

    DiMasi, J A; Hermann, J C; Twyman, K; Kondru, R K; Stergiopoulos, S; Getz, K A; Rackoff, W

    2015-11-01

    We developed an algorithm (ANDI) for predicting regulatory marketing approval for new cancer drugs after phase II testing has been conducted, with the objective of providing a tool to improve drug portfolio decision-making. We examined 98 oncology drugs from the top 50 pharmaceutical companies (2006 sales) that first entered clinical development from 1999 to 2007, had been taken to at least phase II development, and had a known final outcome (research abandonment or regulatory marketing approval). Data on safety, efficacy, operational, market, and company characteristics were obtained from public sources. Logistic regression and machine-learning methods were used to provide an unbiased approach to assess overall predictability and to identify the most important individual predictors. We found that a simple four-factor model (activity, number of patients in the pivotal phase II trial, phase II duration, and a prevalence-related measure) had high sensitivity and specificity for predicting regulatory marketing approval. © 2015 American Society for Clinical Pharmacology and Therapeutics.

  8. Technical design aspects of Feasibility Study-II

    International Nuclear Information System (INIS)

    Zisman, Michael S.

    2001-01-01

    Feasibility Study-II examined a high-performance Neutrino Factory providing 1 x 10 20 neutrinos per year aimed at a long-baseline detector. The Study was sponsored jointly by BNL and the Neutrino Factory and Muon Collider Collaboration ration (MC) and is based on a 1 MW proton driver operating at 24 GeV, i.e., an upgraded version of the AGS accelerator. Compared with the earlier FNAL-sponsored study (Feasibility Study-I), there is a sixfold improvement in performance. Here we describe details of the implementation of Study-II concepts and discuss their efficacy. Alternative approaches that will be pursued in follow-on R and D activities are also described briefly

  9. A risk-based classification scheme for genetically modified foods. II: Graded testing.

    Science.gov (United States)

    Chao, Eunice; Krewski, Daniel

    2008-12-01

    This paper presents a graded approach to the testing of crop-derived genetically modified (GM) foods based on concern levels in a proposed risk-based classification scheme (RBCS) and currently available testing methods. A graded approach offers the potential for more efficient use of testing resources by focusing less on lower concern GM foods, and more on higher concern foods. In this proposed approach to graded testing, products that are classified as Level I would have met baseline testing requirements that are comparable to what is widely applied to premarket assessment of GM foods at present. In most cases, Level I products would require no further testing, or very limited confirmatory analyses. For products classified as Level II or higher, additional testing would be required, depending on the type of the substance, prior dietary history, estimated exposure level, prior knowledge of toxicity of the substance, and the nature of the concern related to unintended changes in the modified food. Level III testing applies only to the assessment of toxic and antinutritional effects from intended changes and is tailored to the nature of the substance in question. Since appropriate test methods are not currently available for all effects of concern, future research to strengthen the testing of GM foods is discussed.

  10. Structural and antimicrobial studies of coordination compounds of VO(II, Co(II, Ni(II and Cu(II with some Schiff bases involving 2-amino-4-chlorophenol

    Directory of Open Access Journals (Sweden)

    A. P. MISHRA

    2009-05-01

    Full Text Available Complexes of tailor-made ligands with life essential metal ions may be an emerging area to answer the problem of multi-drug resistance (MDR. The coordination complexes of VO(II, Co(II, Ni(II and Cu(II with the Schiff bases derived from 2-hydroxyacetophenone/2-chlorobenzaldehyde with 2-ami¬no-4-chlorophenol were synthesized and characterized by elemental analysis, molar conductance, electronic spectra, FT-IR, ESR, FAB mass, thermal and magnetic susceptibility measurements. The FAB mass and thermal data show degradation of the complexes. The ligand A (2-hydroxyacetophenone-2amino-4-chlorophenol behaved as tridentate and ligand B (2-chlorobenzylidene-2-amino-4-chlorophenol as bidentate, coordinating through O and N donors. The complexes [VO(A(H2O]×xH2O, [M(A(H2On]×xH2O for Co and Ni, [Cu(A(H2O] and [VO(B2]×xH2O, [M(B2(H2On] for Co and Cu and [Ni(B2] exhibited coordination numbers 4, 5 or 6. X-ray powder diffraction data (a = 11.00417 Å, b = 11.706081 Å and c = 54.46780 Å showed that [Cu(CACP2(H2O2], complex 8, crystallized in the orthorhombic system. The in vitro biological screening effects of the investigated compounds were tested against the bacteria Escherichia coli, Staphylococcus aureus and Streptococcus fecalis and the fungi Aspergillus niger, Trichoderma polysporum and Candida albicans by the serial dilution method. A comparative study of the MIC values of the Schiff base and their [M(B2(H2O2] complexes (Co(II, complex 6 and Cu(II, complex 8, indicated that the metal complexes exhibited a higher or lower antimicrobial activity than 2-chlorobenzylidene-2-amino-4-chlorophenol as the free ligand (B.

  11. The roles of EBR-II and TREAT [Transient Reactor Test] in establishing liquid metal reactor safety

    International Nuclear Information System (INIS)

    Sackett, J.I.; Lehto, W.K.; Solbrig, C.W.

    1990-01-01

    This paper examines the role of the Experimental Breeder Reactor II (EBR-II) and Transient Reactor Test (TREAT) facilities in contributing to the understanding and resolution of key safety issues in liquid metal reactor safety during the decade of the 80's. Fuels and materials testing has been carried out to address questions on fuels behavior during steady-state and upset conditions. In addition, EBR-II has conducted plant tests to demonstrate passive response to ATWS events and to develop control and diagnostic strategies for safe operation of advanced LMRs. TREAT and EBR-II complement each other and between them provide a transient testing capability that covers the whole range of concerns during overpower conditions. EBR-II, with use of the special Automatic Control Rod Drive System, can generate power change rates that overlap the lower end of the TREAT capability. 21 refs

  12. Halide test agent replacement study

    Energy Technology Data Exchange (ETDEWEB)

    Banks, E.M.; Freeman, W.P.; Kovach, B.J. [and others

    1995-02-01

    The intended phaseout of the chlorofluorocarbons (CFCs) from commercial use required the evaluation of substitute materials for the testing for leak paths through both individual adsorbers and installed adsorbent banks. The American Society of Mechanical Engineers (ASME) Committee on Nuclear Air and Gas Treatment (CONAGT) is in charge of maintaining the standards and codes specifying adsorbent leak test methods for the nuclear safety related air cleaning systems. The currently published standards and codes cite the use of R-11, R-12 and R-112 for leak path test agents. All of these compounds are CFCs. There are other agencies and organizations (USDOE, USDOD and USNRC) also specifying testing for leak paths or in some cases for special life tests using the above compounds. The CONAGT has recently developed criteria for the suitability evaluation of substitute test agents. On the basis of these criteria, several compounds were evaluated for their acceptability as adsorbent bed leak and life test agents. The ASME CONAGT Test Agent Qualification Criteria. The test agent qualification is based on the following parameters: (1) Similar retention times on activated carbons at the same concentration levels as one of the following: R-11, R-12, R-112 or R-112a. (2) Similar lower detection limit sensitivity and precision in the concentration range of use as R-11, R-12, R-112 and R-112a. (3) Gives the same in-place leak test results as R-11, R-12, R-112, or R-112a. (4) Chemical and radiological stability under the use conditions. (5) Causes no degradation of the carbon and its impregnant or of the other NATS components under the use conditions. (6) Is listed in the USEPA Toxic Substances Control Act (TSCA) inventory for commercial use.

  13. Studies on the interaction of benzotriazole (a corrosion inibitor) with the ruthenium (II) (III) ammincomplexes and pentacyanoferrate (II)

    International Nuclear Information System (INIS)

    Espinoza R, R.L.

    1985-01-01

    Some studies on the interaction of benzotriazole with the aquapentacyanoferrate (II), aquapentaamminruthenium (II) and cis-and trans-(NH 3 ) 4 Ru(H 2 O) 2 2+ complexes are described. The reactions, substituted products and complexes production are demonstrated. The absorption bands for the ammine (benzotriazole) and ruthenium (II) complexes as well as the activation parameters and kinetics of reactions are discussed. (M.J.C.) [pt

  14. Vibration test of 1/5 scale H-II launch vehicle

    Science.gov (United States)

    Morino, Yoshiki; Komatsu, Keiji; Sano, Masaaki; Minegishi, Masakatsu; Morita, Toshiyuki; Kohsetsu, Y.

    In order to predict dynamic loads on the newly designed Japanese H-II launch vehicle, the adequacy of prediction methods has been assessed by the dynamic scale model testing. The three-dimensional dynamic model was used in the analysis to express coupling effects among axial, lateral (pitch and yaw) and torsional vibrations. The liquid/tank interaction was considered by use of a boundary element method. The 1/5 scale model of the H-II launch vehicle was designed to simulate stiffness and mass properties of important structural parts, such as core/SRB junctions, first and second stage Lox tanks and engine mount structures. Modal excitation of the test vehicle was accomplished with 100-1000 N shakers which produced random or sinusoidal vibrational forces. The vibrational response of the test vehicle was measured at various locations with accelerometers and pressure sensor. In the lower frequency range, corresmpondence between analysis and experiment was generally good. The basic procedures in analysis seem to be adequate so far, but some improvements in mathematical modeling are suggested by comparison of test and analysis.

  15. Synthesis, molecular structure, biological properties and molecular docking studies on Mn(II), Co(II) and Zn(II) complexes containing bipyridine-azide ligands.

    Science.gov (United States)

    Thamilarasan, Vijayan; Jayamani, Arumugam; Sengottuvelan, Nallathambi

    2015-01-07

    Metal complexes of the type Mn(bpy)2(N3)2 (1), Co(bpy)2(N3)2·3H2O (2) and Zn2(bpy)2(N3)4 (3) (Where bpy = 2,2-bipyridine) have been synthesized and characterized by elemental analysis and spectral (FT-IR, UV-vis) studies. The structure of complexes (1-3) have been determined by single crystal X-ray diffraction studies and the configuration of ligand-coordinated metal(II) ion was well described as distorted octahedral coordination geometry for Mn(II), Co(II) and distorted square pyramidal geometry for Zn(II) complexes. DNA binding interaction of these complexes (1-3) were investigated by UV-vis absorption, fluorescence circular dichroism spectral and molecular docking studies. The intrinsic binding constants Kb of complexes 1, 2 and 3 with CT-DNA obtained from UV-vis absorption studies were 8.37 × 10(4), 2.23 × 10(5) and 5.52 × 10(4) M(-1) respectively. The results indicated that the three complexes are able to bind to DNA with different binding affinity, in the order 2 > 1 > 3. Complexes (1-3) exhibit a good binding propensity to bovine serum albumin (BSA) proteins having relatively high binding constant values. Gel electrophoresis assay demonstrated the ability of the complexes 1-3 promote the cleavage ability of the pBR322 plasmid DNA in the presence of the reducing agent 3-mercaptopropionic acid (MPA) but with different cleavage mechanisms: the complex 3 cleaves DNA via hydrolytic pathway (T4 DNA ligase assay), while the DNA cleavage by complexes 1 and 2 follows oxidative pathway. The chemical nuclease activity follows the order: 2 > 1 > 3. The effects of various activators were also investigated and the nuclease activity efficacy followed the order MPA > GSH > H2O2 > Asc. The cytotoxicity studies of complexes 1-3 were tested in vitro on breast cancer cell line (MCF-7) and they found to be active. Copyright © 2014. Published by Elsevier Masson SAS.

  16. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. II. Test series after Hardtack II, 1958, and summary

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Ricker, Y.E.; Black, S.C.; Grossman, R.F.; Wheeler, D.L.; Church, B.W.; Quinn, V.E.

    1990-01-01

    The historical data on the cumulative individual external gamma exposures are tabulated for communities around the Nevada Test Site for the time periods of 1961 to the signing of the Limited Test Ban Treaty on 5 August 1963, and from then until 1975. The collective exposures during the two time periods are calculated to be 610 and 320 person-R, respectively. The total collective external gamma exposure from 1951 through 1975 for these communities s calculated to be 86,000 person-R. The area considered includes the countries of Clark, Lincoln, Nye, and White Pine in Nevada and the countries of Iron and Washington in Utah; inclusion of Salt Lake City would have substantially increased the calculated collective exposure because of the large population. The methods of calculation are reviewed. Also, the historical data on the assessment of dose via ingestion are reviewed with emphasis on the dose to the thyroid of infants living in St. George, UT, at the time of fallout from event HARRY on 19 May 1953

  17. Project management of the build of the shore test facility for the prototype of PWR II

    International Nuclear Information System (INIS)

    Clarkson, D.T.

    1987-01-01

    The PWR II is a new design of nuclear steam raising plant for the Royal Navy's submarines. It features improved engineering for safety, increased power, increased shock resistance, reduced noise transmission to sea and reduced manning requirement. It is to be tested in a new prototype testing facility, the Shore Test Facility, which is a section of submarine hull containing a prototype of the nuclear steam raising plant and its support system. It is installed at the Vulcan Naval Reactor Test establishment at Dounreay in Scotland. The function of the establishment is to test new designs of core and reactor plant, validate the mathematical models used in their design, develop improved methods of operation and maintenance of the plant and test new items of equipment. The Shore Test Facility was built in large sections at Barrow-in-Furness and transported to Scotland. The project management for the construction of the Shore Test Facility is explained. It involves personnel from the Royal Navy, and a large number of people working for the contractors involved in the buildings, transportation, operation and maintenance of the Facility. (U.K.)

  18. Type II Modic Changes May not Always Represent Fat Degeneration: A Study Using MR Fat Suppression Sequence.

    Science.gov (United States)

    Feng, Zhiyun; Liu, Yuanhao; Wei, Wei; Hu, Shengping; Wang, Yue

    2016-08-15

    A radiological study of type II Modic changes (MCs). The aim of this study was to determine the characteristics of type II MCs on fat suppression (FS) magnetic resonance (MR) images and its association with radiological disc degeneration. Type II MCs are common endplate signal changes on MR images. On the basis of limited histological samples, type II MCs are thought to be stable fat degeneration. FS technique on MR, which can quantify fat content, may be an alternative to explore the pathology of MCs. To date, however, the characteristics of type II MCs on FS sequence have not been studied. Lumbar MR images conducted in a single hospital during a defined period were reviewed to include those with type II MCs and FS images. On FS images, signal status of type II MCs was visually classified as suppressed or not-suppressed. Signal intensity of vertebral regions with and without MCs was measured quantitatively on T2-weighted (T2W) and FS images to calculate fat content index and validate the visual classification. Using image analysis program Osirix, MCs size and adjacent disc degeneration were measured quantitatively. Paired t-tests and logistic regressions were used to determine the associations studied. Sixty-four lumbar MRIs were included and 150 endplates with type II MCs were studied. Although signal of 37 (24.7%) type II MCs was suppressed on FS images, that of 113 (75.3%) was not suppressed. The discs adjacent to type II MCs had lower signal intensity (0.13 ± 0.003 vs. 0.14 ± 0.004, P Type II MCs that were not suppressed on FS image were associated with greater age [odds ratio (OR) = 1.11, P type II MCs was not suppressed on FS MR images, suggesting that there are ongoing complicated pathologies. Type II MCs may not merely represent fat replacement. 3.

  19. Equilibrium and kinetic studies of Pb(II, Cd(II and Zn(II sorption by Lagenaria vulgaris shell

    Directory of Open Access Journals (Sweden)

    Mitić-Stojanović Dragana-Linda

    2012-01-01

    Full Text Available The sorption of lead, cadmium and zinc ions from aqueous solution by Lagenaria vulgaris shell biosorbent (LVB in batch system was investigated. The effect of relevant parameters such as contact time, biosorbent dosage and initial metal ions concentration was evaluated. The Pb(II, Cd(II and Zn(II sorption equilibrium (when 98% of initial metal ions were sorbed was attained within 15, 20 and 25 min, respectively. The pseudo first, pseudo-second order, Chrastil’s and intra-particle diffusion models were used to describe the kinetic data. The experimental data fitted the pseudo-second order kinetic model and intra-particle diffusion model. Removal efficiency of lead(II, cadmium(II and zinc(II ions rapidly increased with increasing biosorbent dose from 0.5 to 8.0 g dm-3. Optimal biosorbent dose was set to 4.0 g dm-3. An increase in the initial metal concentration increases the sorption capacity. The sorption data of investigated metal ions are fitted to Langmuir, Freundlich and Temkin isotherm models. Langmuir model best fitted the equilibrium data (r2 > 0.99. Maximal sorption capacities of LVB for Pb(II, Cd(II and Zn(II at 25.0±0.5°C were 0.130, 0.103 and 0.098 mM g-1, respectively. The desorption experiments showed that the LVB could be reused for six cycles with a minimum loss of the initial sorption capacity.

  20. Evaluation report on CCTF Core-II reflood Test C2-15 (Run 75)

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Iguchi, Tadashi; Akimoto, Hajime; Murao, Yoshio

    1992-01-01

    This report presents an evaluation on the CCTF Core-II Test C2-15 (Run 75). The purpose of the test is to investigate whether the thermo-hydrodynamic behavior is different between the CCTF and the FLECHT-SET reflooding tests. For this purpose, test conditions of the present test were set as close as possible to those of concerned FLECHT-SET 2714B experiment, taking account of differences in facility design. Investigating results of both the tests, the following conclusions are obtained: (1) Some discrepancies were observed in the measured test conditions between the two tests. Out of them, difference in the Acc injection duration was large and affected test results, such as the water accumulation in the downcomer and the core and the core cooling, during the initial period. However, this effect was found to become small with time. (2) Taking account of this difference and the difference in the broken cold leg pressure loss coefficient between the two facilities, the overall reflooding behavior is judged to be similar in the two facilities. (3) The CCTF test results showed the core heat transfer enhancement in the higher power region due to its steep radial power distribution, whereas the FLECHT-SET did not due to its rather flat radial power distribution. This enhancement was observed significantly at 1.83 m but was smaller at the higher elevation. (4) The heat transfer was nearly identical between the two tests and an existing correlation could well predict the heat transfer coefficients of both the tests at the location where the heat transfer enhancement mentioned above (3) were small, during the time period when the effect of the difference in the Acc injection mentioned above (1) were small. (5) Therefore, the core cooling is expected to be almost the same in the CCTF and the FLECHT-SET under the same core boundary conditions and core radial power distribution. (author)

  1. A Comparative Study on the Sorption Characteristics of Pb(II and Hg(II onto Activated Carbon

    Directory of Open Access Journals (Sweden)

    N. Muthulakshmi Andal

    2010-01-01

    Full Text Available Biosorption equilibrium and kinetics of Pb(II and Hg(II on coconut shell carbon (CSC were investigated by batch equilibration method. The effects of pH, adsorbent dosage, contact time, temperature and initial concentration of Pb(II and Hg(II on the activated carbon of coconut shell wastes were studied. Maximum adsorption of Pb(II occurred at pH 4.5 and Hg(II at pH 6. The sorptive mechanism followed the pseudo second order kinetics. The equilibrium data were analysed by Langmuir, Freundlich and Dubinin-Radushkevich isotherm models. The equilibration data fitted well with both Langmuir and Freundlich isotherm model. The Langmuir adsorption capacity for Pb(II was greater than Hg(II. The mean free energy of adsorption calculated from Dubinin-Radushkevich (D-R isotherm model indicated that the adsorption of metal ions was found to be by chemical ion exchange. Thermodynamic parameter showed that the sorption process of Pb(II onto SDC was feasible, spontaneous and endothermic under studied conditions. A comparison was evaluated for the two metals.

  2. Testing DARKexp against energy and density distributions of Millennium-II halos

    Energy Technology Data Exchange (ETDEWEB)

    Nolting, Chris; Williams, Liliya L.R. [School of Physics and Astronomy, University of Minnesota, 116 Church Street SE, Minneapolis, MN, 55454 (United States); Boylan-Kolchin, Michael [Department of Astronomy, The University of Texas at Austin, 2515 Speedway, Stop C1400, Austin, TX, 78712 (United States); Hjorth, Jens, E-mail: nolting@astro.umn.edu, E-mail: llrw@astro.umn.edu, E-mail: mbk@astro.as.utexas.edu, E-mail: jens@dark-cosmology.dk [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, Copenhagen, DK-2100 Denmark (Denmark)

    2016-09-01

    We test the DARKexp model for relaxed, self-gravitating, collisionless systems against equilibrium dark matter halos from the Millennium-II simulation. While limited tests of DARKexp against simulations and observations have been carried out elsewhere, this is the first time the testing is done with a large sample of simulated halos spanning a factor of ∼ 50 in mass, and using independent fits to density and energy distributions. We show that DARKexp, a one shape parameter family, provides very good fits to the shapes of density profiles, ρ( r ), and differential energy distributions, N ( E ), of individual simulated halos. The best fit shape parameter φ{sub 0} obtained from the two types of fits are correlated, though with scatter. Our most important conclusions come from ρ( r ) and N ( E ) that have been averaged over many halos. These show that the bulk of the deviations between DARKexp and individual Millennium-II halos come from halo-to-halo fluctuations, likely driven by substructure, and other density perturbations. The average ρ( r ) and N ( E ) are quite smooth and follow DARKexp very closely. The only deviation that remains after averaging is small, and located at most bound energies for N ( E ) and smallest radii for ρ( r ). Since the deviation is confined to 3–4 smoothing lengths, and is larger for low mass halos, it is likely due to numerical resolution effects.

  3. Alfven wave heating studies in Tokapole II tokamak

    International Nuclear Information System (INIS)

    Kortbawi, D.; Witherspoon, F.D.; Zhu, S.Y.; Casavant, T.; Sprott, J.C.; Prager, S.C.

    1984-01-01

    In earlier experiments at low power on the Tokapole II tokamak using the internal divertor rings as a launching structure the authors have observed a resonance with properties consistent with those expected for a shear Alfven wave. With these encouraging results, a second phase of experiments has begun where, eventually, 4 discrete antennas, located ≅180 0 apart in both the toroidal and poloidal directions and phased to establish proper mode numbers are driven from a 1 MW source. A prototype antenna has been installed and tested. It is a 2 turn Faraday shielded loop extending 54 0 along a toroidal arc. This orientation was chosen for the antenna currents based on the earlier experiments and the simple MHD result that the component of the wage magnetic field perpendicular to the equilibrium field is most strongly divergent. To test this the antenna can be rotated +.45 0 . It can also be inserted radially up to 6 cm

  4. A study on adsorption of Pb(II), Cr(Ш) and Cu(II) from aqueous ...

    African Journals Online (AJOL)

    Peanut husk has been used in this work for removing Pb(II), Cr(Ш) and Cu(II) from aqueous solution. Batch adsorption studies were carried out under different pH, initial concentration of metal ions, interfering metal ions, time and temperature. Adsorption was poor in strongly acidic solution but was improved in alkaline ...

  5. Usability Testing: A Case Study.

    Science.gov (United States)

    Chisman, Janet; Walbridge, Sharon; Diller, Karen

    1999-01-01

    Discusses the development and results of usability testing of Washington State University's Web-based OPAC (online public access catalog); examines how easily users could navigate the catalog and whether they understood what they were seeing; and identifies problems and what action if any was taken. (LRW)

  6. The application and evaluation of insulin release test and quantitative parameter in diabetic type II

    International Nuclear Information System (INIS)

    Huang Chenggang; Chen Xiaoyan; Guan Xiaofeng

    2002-01-01

    Objective: To analyse the curve of Insulin Release Test (IRT) about the patients whit type II diabetes, to evaluate β-cell function and the sensitivity of body to Insulin using Insulin Release Index (IRI) and Insulin Sensitivity Index (ISI), and to probe the value for clinical therapy. Methods: 1) Have a IRT of 396 cases with type II diabetes and 17 normal bodies and acquire the IRT curve, 2) Design the count methods about IRI and ISI, IRI = Ins max/Ins FBI x Δ Ins max/T max (minute), ISI=(Ins max-Ins FBI)/(Ins 180'-Ins FBI), 3) Compare IRI Changes of before and after treatment for 12 cases with no insulin release and 9 cases with less insulin release. Results: IRT curve type (No release type 21.0%, less release type 33.3%, peak delay type 36.9%, high insulin type 6.0%, release delay type 2.8%); respective IRI, ISI compared to normal, P<0.01; IRI of before and after treatment with insulin P<0.01. Conclusions: IRT Curve combining IRI and ISI can reflect accurately β-cell function with type II diabetes and the sensitivity of body to insulin, Also it has some reference value for clinical therapy

  7. Investigation of the utility of colorectal function tests and Rome II criteria in dyssynergic defecation (Anismus).

    Science.gov (United States)

    Rao, S S C; Mudipalli, R S; Stessman, M; Zimmerman, B

    2004-10-01

    Although 30-50% of constipated patients exhibit dyssynergia, an optimal method of diagnosis is unclear. Recently, consensus criteria have been proposed but their utility is unknown. To examine the diagnostic yield of colorectal tests, reproducibility of manometry and utility of Rome II criteria. A total of 100 patients with difficult defecation were prospectively evaluated with anorectal manometry, balloon expulsion, colonic transit and defecography. Fifty-three patients had repeat manometry. During attempted defecation, 30 showed normal and 70 one of three abnormal manometric patterns. Forty-six patients fulfilled Rome criteria and showed paradoxical anal contraction (type I) or impaired anal relaxation (type III) with adequate propulsion. However, 24 (34%) showed impaired propulsion (type II). Forty-five (64%) had slow transit, 42 (60%) impaired balloon expulsion and 26 (37%) abnormal defecography. Defecography provided no additional discriminant utility. Evidence of dyssynergia was reproducible in 51 of 53 patients. Symptoms alone could not differentiate dyssynergic subtypes or patients. Dyssynergic patients exhibited three patterns that were reproducible: paradoxical contraction, impaired propulsion and impaired relaxation. Although useful, Rome II criteria may be insufficient to identify or subclassify dyssynergic defecation. Symptoms together with abnormal manometry, abnormal balloon expulsion or colonic marker retention are necessary to optimally identify patients with difficult defecation.

  8. SASSYS validation with the EBR-II shutdown heat removal tests

    International Nuclear Information System (INIS)

    Herzog, J.P.

    1989-01-01

    SASSYS is a coupled neutronic and thermal hydraulic code developed for the analysis of transients in liquid metal cooled reactors (LMRs). The code is especially suited for evaluating of normal reactor transients -- protected (design basis) and unprotected (anticipated transient without scram) transients. Because SASSYS is heavily used in support of the IFR concept and of innovative LMR designs, such as PRISM, a strong validation base for the code must exist. Part of the validation process for SASSYS is analysis of experiments performed on operating reactors, such as the metal fueled Experimental Breeder Reactor -- II (EBR-II). During the course of a series of historic whole-plant experiments, EBR-II illustrated key safety features of metal fueled LMRs. These experiments, the Shutdown Heat Removal Tests (SHRT), culminated in unprotected loss of flow and loss of heat sink transients from full power and flow. Analysis of these and earlier SHRT experiments constitutes a vital part of SASSYS validation, because it facilitates scrutiny of specific SASSYS models and of integrated code capability. 12 refs., 11 figs

  9. Engineering and Cryogenic Testing of the ISAC-II Medium Beta Cryomodule

    CERN Document Server

    Stanford, G; Laxdal, R E; Rawnsley, B; Ries, T; Sekatchev, I

    2004-01-01

    The medium beta section of the ISAC-II Heavy Ion Accelerator consists of five cryomodules each containing four quarter wave bulk niobium resonators and one superconducting solenoid. A prototype cryomodule has been designed and assembled at TRIUMF. The cryomodule vacuum space contains a mu-metal shield, an LN2 cooled, copper, thermal shield, plus the cold mass and support system. This paper will describe the design goals, engineering choices and fabrication and assembly techniques as well as report the results of the initial cold tests. In particular we will summarize the alignment procedure and the results from the wire position monitoring system.

  10. Some tests of the basic properties of the neutral weak interaction. II. With massive neutrinos

    International Nuclear Information System (INIS)

    Dass, G.V.; Babu, P.R.

    1983-01-01

    Assuming a general nonderivative point interaction, and Born approximation, the angular distributions for neutrino scatterings by electrons are written, using only simple considerations, allowing all leptons to have nonzero mass. Our distributions have been previously obtained for some special cases, from general considerations by Bell et al., or in the results of explicit calculations. Applications to (i) determination of the Lorentz structure of the neutral weak interaction, and (ii) tests of lepton locality are considered. For illustration, two explicit calculations are given; one of these could hold for heavy lepton production, and the other for scattering of very low energy cosmic neutrinos

  11. Product-Improvement Test (Phase II), Jetcal Tester, Model H119A.

    Science.gov (United States)

    1969-03-05

    Ao—A0 51 113 ARMY AVIATION ‘Cs’ BOARD FORT tUCKER ALA — P*OOUCTeII ROVEMCNT TEST ( FHAS ~ I I ) . JETCAL TESTER, MODEL M119A~~’ETC(U) MAR S9...Phase i i ) , Jetcal Tester , Model H 119A , USATECOM Project No. 4-6-5011-03 b . No fur ther consideration be given to the TEMPCAL heater probe as a...essen t i a l component of the Jetcal Tester. e. The service manual instruct ions for con t inu i ty te s t ing of EG1 thermocouples be revised to

  12. Testing time for Siemens/KWU's PRINS/PRISCA at Isar II and Emsland

    International Nuclear Information System (INIS)

    Aleite, W.

    1988-01-01

    The culmination of work started in the early 1970s, the first PRINS/PRISCA process information system has recently been through commissioning tests at the new Isar II and Emsland convoy PWRS. PRINS/PRISCA is a human factor orientated, fully redundant, distributed, real time computer system with full graphic capabilities and standardized pictorial symbols. It also features elements of artificial intelligence and an innovative presentation of information, using banks of up to eight screens. KWU reports that reactions from operators have been increasingly positive. (author)

  13. Saturn V Second Stage (S-II) Ready for Static Test

    Science.gov (United States)

    1965-01-01

    Two workers are dwarfed by the five J-2 engines of the Saturn V second stage (S-II) as they make final inspections prior to a static test firing by North American Space Division. These five hydrogen -fueled engines produced one million pounds of thrust, and placed the Apollo spacecraft into earth orbit before departing for the moon. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  14. A miniature bioassay for testing the acute phytotoxicity of photosystem II herbicides on seagrass.

    Directory of Open Access Journals (Sweden)

    Adam D Wilkinson

    Full Text Available Photosystem II (PSII herbicides have been detected in nearshore tropical waters such as those of the Great Barrier Reef and may add to the pressure posed by runoff containing sediments and nutrients to threatened seagrass habitats. There is a growing number of studies into the potential effects of herbicides on seagrass, generally using large experimental setups with potted plants. Here we describe the successful development of an acute 12-well plate phytotoxicity assay for the PSII herbicide Diuron using isolated Halophila ovalis leaves. Fluorescence images demonstrated Diuron affected the entire leaf surface evenly and responses were not influenced by isolating leaves from the plant. The optimum exposure duration was 24 h, by which time the inhibition of effective quantum yield of PSII (∆F/F(m' was highest and no deterioration of photosystems was evident in control leaves. The inhibition of ∆F/F(m' by Diuron in isolated H. ovalis leaves was identical to both potted and hydroponically grown plants (with leaves remaining attached to rhizomes, indicating similar reductions in photosynthetic activity in these acute well-plate assays. The sensitivity of the assay was not influenced by irradiance (range tested 40 to 400 μmol photons m(-2 s(-1. High irradiance, however, caused photo-oxidative stress in H. ovalis and this generally impacted in an additive or sub-additive way with Diuron to damage PSII. The bioassay using isolated leaves is more rapid, uses far less biological material and does not rely on specialised aquarium facilities in comparison with assays using potted plants. The development and validation of this sensitive bioassay will be useful to reliably screen and monitor the phytotoxicity of existing and emerging PSII herbicides and contribute to risk assessments and water quality guideline development in the future.

  15. A Miniature Bioassay for Testing the Acute Phytotoxicity of Photosystem II Herbicides on Seagrass

    Science.gov (United States)

    Wilkinson, Adam D.; Collier, Catherine J.; Flores, Florita; Mercurio, Phil; O’Brien, Jake; Ralph, Peter J.; Negri, Andrew P.

    2015-01-01

    Photosystem II (PSII) herbicides have been detected in nearshore tropical waters such as those of the Great Barrier Reef and may add to the pressure posed by runoff containing sediments and nutrients to threatened seagrass habitats. There is a growing number of studies into the potential effects of herbicides on seagrass, generally using large experimental setups with potted plants. Here we describe the successful development of an acute 12-well plate phytotoxicity assay for the PSII herbicide Diuron using isolated Halophila ovalis leaves. Fluorescence images demonstrated Diuron affected the entire leaf surface evenly and responses were not influenced by isolating leaves from the plant. The optimum exposure duration was 24 h, by which time the inhibition of effective quantum yield of PSII (∆F/Fm’) was highest and no deterioration of photosystems was evident in control leaves. The inhibition of ∆F/Fm’ by Diuron in isolated H. ovalis leaves was identical to both potted and hydroponically grown plants (with leaves remaining attached to rhizomes), indicating similar reductions in photosynthetic activity in these acute well-plate assays. The sensitivity of the assay was not influenced by irradiance (range tested 40 to 400 μmol photons m-2 s-1). High irradiance, however, caused photo-oxidative stress in H. ovalis and this generally impacted in an additive or sub-additive way with Diuron to damage PSII. The bioassay using isolated leaves is more rapid, uses far less biological material and does not rely on specialised aquarium facilities in comparison with assays using potted plants. The development and validation of this sensitive bioassay will be useful to reliably screen and monitor the phytotoxicity of existing and emerging PSII herbicides and contribute to risk assessments and water quality guideline development in the future. PMID:25674791

  16. The Collaborative Longitudinal Personality Disorders Study: baseline Axis I/II and II/II diagnostic co-occurrence.

    Science.gov (United States)

    McGlashan, T H; Grilo, C M; Skodol, A E; Gunderson, J G; Shea, M T; Morey, L C; Zanarini, M C; Stout, R L

    2000-10-01

    To describe baseline diagnostic co-occurrence in the Collaborative Longitudinal Personality Disorders Study. Six hundred and sixty-eight patients were reliably assessed with diagnostic interviews for DSM-IV Axis I and II disorders to create five groups: Schizotypal (STPD), Borderline (BPD), Avoidant (AVPD), Obsessive-Compulsive (OCPD) and Major Depressive Disorder (MDD) without personality disorder (PD). Mean number of Axis I lifetime diagnoses was 3.4; STPD and BPD groups had more diagnoses than AVPD, OCPD, and MDD groups. Significant Axis I co-occurrences emerged for Social Phobia/ AVPD, PTSD/BPD and Substance Use/BPD. Mean number of co-occurring PDs was 1.4; STPD had more than BPD group which had more than AVPD and OCPD groups. Significant PD co-occurrence emerged for: STPD/ Paranoid and Schizoid PDs, BPD with Antisocial and Dependent PDs, and lower frequency for OCPD/Antisocial PD. Diagnostic co-occurrences generally followed base rates, while significant departures resemble those of controlled literature.

  17. Pharyngeal airway dimensions in skeletal class II: A cephalometric growth study

    International Nuclear Information System (INIS)

    Uslu-Akcam, Ozge

    2017-01-01

    This retrospective study aimed to evaluate the nasopharyngeal and oropharyngeal dimensions of individuals with skeletal class II, division 1 and division 2 patterns during the pre-peak, peak, and post-peak growth periods for comparison with a skeletal class I control group. Totally 124 lateral cephalograms (47 for skeletal class I; 45 for skeletal class II, division 1; and 32 for skeletal class II, division 2) in pre-peak, peak, and post-peak growth periods were selected from the department archives. Thirteen landmarks, 4 angular and 4 linear measurements, and 4 proportional calculations were obtained. The ANOVA and Duncan test were applied to compare the differences among the study groups during the growth periods. Statistically significant differences were found between the skeletal class II, division 2 group and other groups for the gonion-gnathion/sella-nasion angle. The sella-nasion-B-point angle was different among the groups, while the A-point-nasion-B-point angle was significantly different for all 3 groups. The nasopharyngeal airway space showed a statistically significant difference among the groups throughout the growth periods. The interaction among the growth periods and study groups was statistically significant regarding the upper oropharyngeal airway space measurement. The lower oropharyngeal airway space measurement showed a statistically significant difference among the groups, with the smallest dimension observed in the skeletal class II, division 2 group. The naso-oropharyngeal airway dimensions showed a statistically significant difference among the class II, division 1; class II, division 2; and class I groups during different growth periods

  18. Pharyngeal airway dimensions in skeletal class II: A cephalometric growth study

    Energy Technology Data Exchange (ETDEWEB)

    Uslu-Akcam, Ozge [Clinic of Orthodontics, Ministry of Health, Tepebasi Oral and Dental Health Hospital, Ankara (Turkmenistan)

    2017-03-15

    This retrospective study aimed to evaluate the nasopharyngeal and oropharyngeal dimensions of individuals with skeletal class II, division 1 and division 2 patterns during the pre-peak, peak, and post-peak growth periods for comparison with a skeletal class I control group. Totally 124 lateral cephalograms (47 for skeletal class I; 45 for skeletal class II, division 1; and 32 for skeletal class II, division 2) in pre-peak, peak, and post-peak growth periods were selected from the department archives. Thirteen landmarks, 4 angular and 4 linear measurements, and 4 proportional calculations were obtained. The ANOVA and Duncan test were applied to compare the differences among the study groups during the growth periods. Statistically significant differences were found between the skeletal class II, division 2 group and other groups for the gonion-gnathion/sella-nasion angle. The sella-nasion-B-point angle was different among the groups, while the A-point-nasion-B-point angle was significantly different for all 3 groups. The nasopharyngeal airway space showed a statistically significant difference among the groups throughout the growth periods. The interaction among the growth periods and study groups was statistically significant regarding the upper oropharyngeal airway space measurement. The lower oropharyngeal airway space measurement showed a statistically significant difference among the groups, with the smallest dimension observed in the skeletal class II, division 2 group. The naso-oropharyngeal airway dimensions showed a statistically significant difference among the class II, division 1; class II, division 2; and class I groups during different growth periods.

  19. Study of the GERDA Phase II background spectrum

    Science.gov (United States)

    Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Selivanenko, O.; Shevzik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2017-09-01

    The Gerda experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN in Italy, searches for the neutrinoless double beta (0νββ) decay of 76Ge. Gerda Phase II is aiming to reach a sensitivity for the 0νββ half life of 1026 yr in ˜ 3 years of physics data taking with 100 kg·yr of exposure and a background index of ˜ 10-3 cts/(keV·kg·yr). After 6 months of acquisition a first data release with 10.8 kg·yr of exposure is performed, showing that the design background is achieved. In this work a study of the Phase II background spectrum, the main spectral structures and the background sources will be presented and discussed.

  20. New Mn(II, Ni(II, Cd(II, Pb(II complexes with 2-methylbenzimidazole and other ligands. Synthesis, spectroscopic characterization, crystal structure, magnetic susceptibility and biological activity studies

    Directory of Open Access Journals (Sweden)

    Shayma A. Shaker

    2016-11-01

    Full Text Available Synthesis and characterization of Mn(II, Ni(II, Cd(II and Pb(II mixed ligand complexes of 2-methylbenzimidazole with other ligands have been reported. The structure of the ligands and their complexes was investigated using elemental analysis, IR, UV–Vis, (1H, 13C NMR spectroscopy, molar conductivity and magnetic susceptibility measurements. In all the studies of complexes, the 2-methylbenzimidazole behaves as a neutral monodentate ligand which is coordinated with the metal ions through the N atom. While benzotriazole behaves as a neutral bidentate ligand which is coordinated with the Ni(II ion through the two N atoms. Moreover, the N-acetylglycine behaves as a bidentate ligand which is coordinated with the Mn(II, Ni(II and Pb(II ions through the N atom and the terminal carboxyl oxygen atom. The magnetic and spectral data indicate the tetrahedral geometry for Mn(II complex, irregular tetrahedral geometry for Pb(II complex and octahedral geometry for Ni(II complex. The X-ray single crystal diffraction method was used to confirm a centrosymmetric dinuclear Cd(II complex as each two metal ions are linked by a pair of thiocyanate N = S bridge. Two 2-methylbenzimidazole N-atom donors and one terminal thiocyanate N atom complete a highly distorted square pyramid geometry around the Cd atom. Besides, different cell types were used to determine the inhibitory effect of Mn(II, Ni(II, Cd(II and Pb(II complexes on cell growth using MTT assay. Cd(II complex showed cytotoxic effect on various types of cancer cell lines with different EC50 values.

  1. A performance study of WebDav access to storages within the Belle II collaboration

    Science.gov (United States)

    Pardi, S.; Russo, G.

    2017-10-01

    WebDav and HTTP are becoming popular protocols for data access in the High Energy Physics community. The most used Grid and Cloud storage solutions provide such kind of interfaces, in this scenario tuning and performance evaluation became crucial aspects to promote the adoption of these protocols within the Belle II community. In this work, we present the results of a large-scale test activity, made with the goal to evaluate performances and reliability of the WebDav protocol, and study a possible adoption for the user analysis. More specifically, we considered a pilot infrastructure composed by a set of storage elements configured with the WebDav interface, hosted at the Belle II sites. The performance tests include a comparison with xrootd and gridftp. As reference tests we used a set of analysis jobs running under the Belle II software framework, accessing the input data with the ROOT I/O library, in order to simulate as much as possible a realistic user activity. The final analysis shows the possibility to achieve promising performances with WebDav on different storage systems, and gives an interesting feedback, for Belle II community and for other high energy physics experiments.

  2. Validity of FAA-approved color vision tests for class II and class III aeromedical screening.

    Science.gov (United States)

    1993-09-01

    All clinical color vision tests currently used in the medical examination of pilots were studied regarding validity for prediction of performance on practical tests of ability to discriminate the aviation signal colors, red, green, and white given un...

  3. Development and performance test of a new high power RF window in S-band PLS-II LINAC

    Science.gov (United States)

    Hwang, Woon-Ha; Joo, Young-Do; Kim, Seung-Hwan; Choi, Jae-Young; Noh, Sung-Ju; Ryu, Ji-Wan; Cho, Young-Ki

    2017-12-01

    A prototype of RF window was developed in collaboration with the Pohang Accelerator Laboratory (PAL) and domestic companies. High power performance tests of the single RF window were conducted at PAL to verify the operational characteristics for its application in the Pohang Light Source-II (PLS-II) linear accelerator (Linac). The tests were performed in the in-situ facility consisting of a modulator, klystron, waveguide network, vacuum system, cooling system, and RF analyzing equipment. The test results with Stanford linear accelerator energy doubler (SLED) have shown no breakdown up to 75 MW peak power with 4.5 μs RF pulse width at a repetition rate of 10 Hz. The test results with the current operation level of PLS-II Linac confirm that the RF window well satisfies the criteria for PLS-II Linac operation.

  4. Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plum Constituents Under Test Environment, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Phase II STTR project is to develop a prototype multi-analyte sensor system to detect gaseous analytes present in the test stands during...

  5. Implementation & Flight Testing of IMPACT system for Autonomous ISR using Collaborating UAVs with Application to Wild Fire Monitoring, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — SSCI and MIT propose to further develop, implement and test the Integrated Mission Planning (ii) Robust on-line learning for prediction of the fire spread using the...

  6. FEBEX II Project Final report on thermo-hydro-mechanical laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Lloret, A.; Romero, E.; Villar, M. V.

    2004-07-01

    The results of the thermo-hydro-mechanical (THM) study of the FEBEX bentonite performed during FEBEX II are presented. The laboratory test program continued in part with the works carried out during FEBEX I, particularly in activities related to tests aimed to the calibration of the models, the acquisition of parameters by back-analysis and the improvement of the knowledge on the behaviour of expansive clays. But the program has also included tests on new areas: investigations about the influence of the microstructure changes in bentonite, of temperature and of the solute concentration on the behaviour of clay. Besides, several tests were proposed in order to understand the unexpected behaviour observed in the mock-up test, towards the end of year 2. Temperature effects on water retention curves in confined and unconfined conditions were determined, and swelling pressure, hydraulic conductivity and swelling and consolidation strains as a function of temperature were successfully measured. Different experimental techniques and equipments were developed to study thermal induced changes under partially saturated states, covering a wide range of suctions. FEBEX bentonite remains suitable as a sealing material in HLW repositories (from the hydro- mechanical point of view) for temperatures of up to 80 C, as it keeps its high water retention capacity, low permeability and self-healing ability. The extrapolation of results points out to the preservation of properties for at least up to 100 C. Mercury intrusion porosimetry and environmental scanning electron microscopy provided promising results in order to characterise the bentonite microstructure and to give information about the mechanisms influencing pore size distribution changes on high active clays. The use of digital imaging techniques allowed verifying that at micro-scale level, where chemical phenomena prevail, strains are almost reversible as it is considered in the two-level elasto-plastic models. The swelling

  7. FEBEX II Project Final report on thermo-hydro-mechanical laboratory tests

    International Nuclear Information System (INIS)

    Lloret, A.; Romero, E.; Villar, M. V.

    2004-01-01

    The results of the thermo-hydro-mechanical (THM) study of the FEBEX bentonite performed during FEBEX II are presented. The laboratory test program continued in part with the works carried out during FEBEX I, particularly in activities related to tests aimed to the calibration of the models, the acquisition of parameters by back-analysis and the improvement of the knowledge on the behaviour of expansive clays. But the program has also included tests on new areas: investigations about the influence of the microstructure changes in bentonite, of temperature and of the solute concentration on the behaviour of clay. Besides, several tests were proposed in order to understand the unexpected behaviour observed in the mock-up test, towards the end of year 2. Temperature effects on water retention curves in confined and unconfined conditions were determined, and swelling pressure, hydraulic conductivity and swelling and consolidation strains as a function of temperature were successfully measured. Different experimental techniques and equipments were developed to study thermal induced changes under partially saturated states, covering a wide range of suctions. FEBEX bentonite remains suitable as a sealing material in HLW repositories (from the hydro- mechanical point of view) for temperatures of up to 80 C, as it keeps its high water retention capacity, low permeability and self-healing ability. The extrapolation of results points out to the preservation of properties for at least up to 100 C. Mercury intrusion porosimetry and environmental scanning electron microscopy provided promising results in order to characterise the bentonite microstructure and to give information about the mechanisms influencing pore size distribution changes on high active clays. The use of digital imaging techniques allowed verifying that at micro-scale level, where chemical phenomena prevail, strains are almost reversible as it is considered in the two-level elasto-plastic models. The swelling

  8. Testing the Predictive Validity of the Hendrich II Fall Risk Model.

    Science.gov (United States)

    Jung, Hyesil; Park, Hyeoun-Ae

    2018-03-01

    Cumulative data on patient fall risk have been compiled in electronic medical records systems, and it is possible to test the validity of fall-risk assessment tools using these data between the times of admission and occurrence of a fall. The Hendrich II Fall Risk Model scores assessed during three time points of hospital stays were extracted and used for testing the predictive validity: (a) upon admission, (b) when the maximum fall-risk score from admission to falling or discharge, and (c) immediately before falling or discharge. Predictive validity was examined using seven predictive indicators. In addition, logistic regression analysis was used to identify factors that significantly affect the occurrence of a fall. Among the different time points, the maximum fall-risk score assessed between admission and falling or discharge showed the best predictive performance. Confusion or disorientation and having a poor ability to rise from a sitting position were significant risk factors for a fall.

  9. Installation Progress at the PIP-II Injector Test at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Baffes, C. [Fermilab; Alvarez, M. [Fermilab; Andrews, R. [Fermilab; Chen, A. [Fermilab; Czajkowski, J. [Fermilab; Derwent, P. [Fermilab; Edelen, J. [Fermilab; Hanna, B. [Fermilab; Hartsell, B. [Fermilab; Kendziora, K. [Fermilab; Mitchell, D. [Fermilab; Prost, L. [Fermilab; Scarpine, V. [Fermilab; Shemyakin, A. [Fermilab; Steimel, J. [Fermilab; Zuchnik, T. [Fermilab; Edelen, A. [Colorado State U.

    2016-10-04

    A CW-compatible, pulsed H- superconducting linac “PIP-II” is being planned to upgrade Fermilab's injection complex. To validate the front-end concept, a test acceler-ator (The PIP-II Injector Test, formerly known as "PXIE") is under construction. The warm part of this accelerator comprises a 10 mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV Radio Frequency Quadrupole (RFQ) capable of operation in Con-tinuous Wave (CW) mode, and a 10 m-long Medium En-ergy Beam Transport (MEBT). The paper will report on the installation of the RFQ and the first sections of the MEBT and related mechanical design considerations.

  10. Study of beam dynamics at cooler synchrotron TARN-II

    International Nuclear Information System (INIS)

    Watanabe, S.; Katayama, T.; Watanabe, T.; Yoshizawa, M.; Tomizawa, M.; Chida, K.; Arakaki, Y.; Noda, K.; Kanazawa, M.

    1992-08-01

    Several kinds of beam diagnostic instruments, have been developed at cooler-synchrotron TARN-II. These are intended to study beam dynamics at low beam current of several microamperes and then have high sensitivity of good S/N ratio. In addition, the acceleration system, especially low level RF system, has been improved to attain the maximum beam energy. With the successful performance of these instrumentations, the study of beam dynamics are presently being carried out. For example, the synchrotron acceleration of the light ions was achieved up to 220 MeV/u without any beam loss. (author)

  11. Nuclear Technology. Course 32: Nondestructive Examination (NDE) II. Module 32-3, Fundamentals of Magnetic Particle Testing.

    Science.gov (United States)

    Groseclose, Richard

    This third in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II explains the principles of magnets and magnetic fields and how they are applied in magnetic particle testing, describes the theory and methods of magnetizing test specimens, describes the test equipment used, discusses the principles and…

  12. Benchmark analyses for EBR-II shutdown heat removal tests SHRT-17 and SHRT-45R

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyasu, E-mail: mochizki@u-fukui.ac.jp [Research Institute of Nuclear Engineering, University of Fukui (Japan); Muranaka, Kohmei; Asai, Takayuki [Graduate School of Engineering, University of Fukui (Japan); Rooijen, W.F.G. van, E-mail: rooijen@u-fukui.ac.jp [Research Institute of Nuclear Engineering, University of Fukui (Japan)

    2014-08-15

    Highlights: • The IAEA EBR-II benchmarks SHRT-17 and SHRT-45R are analyzed with a 1D system code. • The calculated result of SHRT-17 corresponds well to the measured results. • For SHRT-45R ERANOS is used for various core parameters and reactivity coefficients. • SHRT-45R peak temperature is overestimated with the ERANOS feedback coefficients. • The peak temperature is well predicted when the feedback coefficient is reduced. - Abstract: Benchmark problems of several experiments in EBR-II, proposed by ANL and coordinated by the IAEA, are analyzed using the plant system code NETFLOW++ and the neutronics code ERANOS. The SHRT-17 test conducted as a loss-of-flow test is calculated using only the NETFLOW++ code because it is a purely thermal–hydraulic problem. The measured data were made available to the benchmark participants after the results of the blind benchmark calculations were submitted. Our work shows that major parameters of the plant are predicted with good accuracy. The SHRT-45R test, an unprotected loss of flow test is calculated using the NETFLOW++ code with the aid of delayed neutron data and reactivity coefficients calculated by the ERANOS code. These parameters are used in the NETFLOW++ code to perform a semi-coupled analysis of the neutronics – thermal–hydraulic problem. The measured data are compared with our calculated results. In our work, the peak temperature is underestimated, indicating that the reactivity feedback coefficients are too strong. When the reactivity feedback coefficient for thermal expansion is adjusted, good agreement is obtained in general for the calculated plant parameters, with a few exceptions.

  13. Studies on Hepa filter test methods

    International Nuclear Information System (INIS)

    Lee, S.H.; Jon, K.S.; Park, W.J.; Ryoo, R.

    1981-01-01

    The purpose of this study is to compare testing methods of the HEPA filter adopted in other countries with each other, and to design and construct a test duct system to establish testing methods. The American D.O.P. test method, the British NaCl test method and several other independently developed methods are compared. It is considered that the D.O.P. method is most suitable for in-plant and leak tests

  14. Testing and Analysis of a Composite Non-Cylindrical Aircraft Fuselage Structure . Part II; Severe Damage

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Lovejoy, Andrew E.; Rouse, Marshall; Wu, Hsi-Yung T.

    2016-01-01

    The Environmentally Responsible Aviation Project aimed to develop aircraft technologies enabling significant fuel burn and community noise reductions. Small incremental changes to the conventional metallic alloy-based 'tube and wing' configuration were not sufficient to achieve the desired metrics. One airframe concept identified by the project as having the potential to dramatically improve aircraft performance was a composite-based hybrid wing body configuration. Such a concept, however, presented inherent challenges stemming from, among other factors, the necessity to transfer wing loads through the entire center fuselage section which accommodates a pressurized cabin confined by flat or nearly flat panels. This paper discusses a finite element analysis and the testing of a large-scale hybrid wing body center section structure developed and constructed to demonstrate that the Pultruded Rod Stitched Efficient Unitized Structure concept can meet these challenging demands of the next generation airframes. Part II of the paper considers the final test to failure of the test article in the presence of an intentionally inflicted severe discrete source damage under the wing up-bending loading condition. Finite element analysis results are compared with measurements acquired during the test and demonstrate that the hybrid wing body test article was able to redistribute and support the required design loads in a severely damaged condition.

  15. Silk I and Silk II studied by fast scanning calorimetry.

    Science.gov (United States)

    Cebe, Peggy; Partlow, Benjamin P; Kaplan, David L; Wurm, Andreas; Zhuravlev, Evgeny; Schick, Christoph

    2017-06-01

    Using fast scanning calorimetry (FSC), we investigated the glass transition and crystal melting of samples of B. mori silk fibroin containing Silk I and/or Silk II crystals. Due to the very short residence times at high temperatures during such measurements, thermal decomposition of silk protein can be significantly suppressed. FSC was performed at 2000K/s using the Mettler Flash DSC1 on fibroin films with masses around 130-270ng. Films were prepared with different crystalline fractions (ranging from 0.26 to 0.50) and with different crystal structures (Silk I, Silk II, or mixed) by varying the processing conditions. These included water annealing at different temperatures, exposure to 50%MeOH in water, or autoclaving. The resulting crystal structure was examined using wide angle X-ray scattering. Degree of crystallinity was evaluated from Fourier transform infrared (FTIR) spectroscopy and from analysis of the heat capacity increment at the glass transition temperature. Silk fibroin films prepared by water annealing at 25°C were the least crystalline and had Silk I structure. FTIR and FSC studies showed that films prepared by autoclaving or 50%MeOH exposure were the most crystalline and had Silk II structure. Intermediate crystalline fraction and mixed Silk I/Silk II structures were found in films prepared by water annealing at 37°C. FSC results indicate that Silk II crystals exhibit endotherms of narrower width and have higher mean melting temperature T m (II)=351±2.6°C, compared to Silk I crystals which melt at T m (I)=292±3.8°C. Films containing mixed Silk I/Silk II structure showed two clearly separated endothermic peaks. Evidence suggests that the two types of crystals melt separately and do not thermally interconvert on the extremely short time scale (0.065s between onset and end of melting) of the FSC experiment. Silkworm silk is a naturally occurring biomaterial. The fibroin component of silk forms two types of crystals. Silk properties depend upon the

  16. Dispersant testing : a study on analytical test procedures

    International Nuclear Information System (INIS)

    Fingas, M.F.; Fieldhouse, B.; Wang, Z.; Environment Canada, Ottawa, ON

    2004-01-01

    Crude oil is a complex mixture of hydrocarbons, ranging from small, volatile compounds to very large, non-volatile compounds. Analysis of the dispersed oil is crucial. This paper described Environment Canada's ongoing studies on various traits of dispersants. In particular, it describes small studies related to dispersant effectiveness and methods to improve analytical procedures. The study also re-evaluated the analytical procedure for the Swirling Flask Test, which is now part of the ASTM standard procedure. There are new and improved methods for analyzing oil-in-water using gas chromatography (GC). The methods could be further enhanced by integrating the entire chromatogram rather than just peaks. This would result in a decrease in maximum variation from 5 per cent to about 2 per cent. For oil-dispersant studies, the surfactant-dispersed oil hydrocarbons consist of two parts: GC-resolved hydrocarbons and GC-unresolved hydrocarbons. This study also tested a second feature of the Swirling Flask Test in which the side spout was tested and compared with a new vessel with a septum port instead of a side spout. This decreased the variability as well as the energy and mixing in the vessel. Rather than being a variation of the Swirling Flask Test, it was suggested that a spoutless vessel might be considered as a completely separate test. 7 refs., 2 tabs., 4 figs

  17. Behavior of EBR-II Mk-V-type fuel elements in simulated loss-of-flow tests

    International Nuclear Information System (INIS)

    Liu, Y.Y.; Tsai, H.; Billone, M.C.; Holland, J.W.; Kramer, J.M.

    1993-01-01

    Three furnace heating tests were conducted with irradiated, HT9-clad and U-19wt%Pu-10wt%Zr-alloy, EBR-II Mk-V-type fuel elements to evaluate the behavior that could be expected during a loss-of-flow event in the reactor. In general, very significant safety margins for cladding breaching have been demonstrated in these tests, under conditions that would envelop a bounding unlikely loss-of-flow event in EBR-II. Highlights of the test results are presented, as are discussions of the cladding breaching mechanisms, axial fuel motion, and fuel surface liquefaction that were found in these tests. (orig.)

  18. ATCA - thermal management study for the ATLAS phase II upgrades

    CERN Document Server

    Bortolin, Claudio; Kalinowski, Michal; Koziol, Piotr; Mendez, Julian; Walerianczyk, Jan; Zwalinski, Lukasz

    2017-01-01

    The AdvancedTCA (ATCA) telecom industry standard has been selected as the hardware platform for the “Phase-II Upgrade” of ATLAS at the Large Hadron Collider (LHC) at CERN. In November 2014 a project dedicated to the study of the impact of the ATCA integration in the actual counting rooms was launched analysing the impact on the cooling infrastructures. A spare rack equipped with two ATCA shelves, high power dissipating load blades, temperature and air velocity sensors were installed in a lab. Vertical and horizontal cooling performance were checked and some crtitical aspects identified.

  19. ATCA - thermal management study for the ATLAS phase II upgrades

    OpenAIRE

    Bortolin, Claudio; Dyngosz, Damian; Kalinowski, Michal; Koziol, Piotr; Mendez, Julian; Walerianczyk, Jan; Zwalinski, Lukasz

    2017-01-01

    The AdvancedTCA (ATCA) telecom industry standard has been selected as the hardware platform for the “Phase-II Upgrade” of ATLAS at the Large Hadron Collider (LHC) at CERN. In November 2014 a project dedicated to the study of the impact of the ATCA integration in the actual counting rooms was launched analysing the impact on the cooling infrastructures. A spare rack equipped with two ATCA shelves, high power dissipating load blades, temperature and air velocity sensors were installed in a lab....

  20. Study of Beam-Beam Effects at PEP-II

    International Nuclear Information System (INIS)

    Narsky, I

    2004-01-01

    Using a self-consistent three-dimensional simulation running on parallel supercomputers, we have modeled the beam-beam interaction at the PEP-II asymmetric e + e - collider. To provide guidance for luminosity improvement, we scanned the tunes and currents in both rings and computed their impact on the luminosity and transverse beam sizes. We also studied the effects of colliding the beams with a small crossing angle. Where possible, the code was benchmarked against experimental measurements of luminosity and beam sizes, yielding an acceptable agreement

  1. Hydramite II screening tests of potential bremsstrahlung converter debris shield materials

    International Nuclear Information System (INIS)

    Reedy, E.D. Jr.; Hedemann, M.A.; Stark, M.A.

    1986-03-01

    Results of a brief test series aimed at screening a number of potential bremsstrahlung converter debris shield materials are reported. These tests were run on Sandia National Laboratories' Hydramite II accelerator using a diode configuration which produces a pinched electron beam. The materials tested include: (1) laminated Kevlar 49/polyester and E-glass/polyester composites, (2) a low density laminated Kevlar 49 composite, and (3) two types of through-the-thickness reinforced Kevlar 49 composites. As expected, tests using laminated Kevlar 49/polyester shields showed that shield permanent set (i.e., permanent deflection) increased with increasing tantalum conversion foil thickness and decreased with increasing shield thickness. The through-the-thickness reinforced composites developed localized, but severe, back surface damage. The laminated composites displayed little back surface damage, although extensive internal matrix cracking and ply delaminations were generated. Roughly the same degree of permanent set was produced in shields made from the low density Kevlar 49 composite and the Kevlar 49/polyester. The E-glass reinforced shields exhibited relatively low levels of permanent set

  2. Type II diabetes mellitus and the incidence of epithelial ovarian cancer in the cancer prevention study-II nutrition cohort.

    Science.gov (United States)

    Gapstur, Susan M; Patel, Alpa V; Diver, W Ryan; Hildebrand, Janet S; Gaudet, Mia M; Jacobs, Eric J; Campbell, Peter T

    2012-11-01

    Despite consistent associations of type II diabetes mellitus with hormonally related cancers such as breast and endometrium, the relation between type II diabetes mellitus and ovarian cancer risk is unclear. Associations of type II diabetes mellitus status, duration, and insulin use with epithelial ovarian cancer overall, and with serous and nonserous histologic subtypes were examined in the Cancer Prevention Study-II Nutrition Cohort, a prospective study of U.S. men and women predominantly aged 50 years and older. Between 1992 and 2007, 524 incident epithelial ovarian cancer cases were identified among 63,440 postmenopausal women. Multivariable-adjusted relative risks (RR) and 95% confidence intervals (CI) were computed using extended Cox regression to update diabetes status and bilateral oophorectomy status during follow-up. Type II diabetes mellitus status (RR = 1.05; 95% CI, 0.75-1.46) and duration were not associated with epithelial ovarian cancer risk. Although not statistically significantly different (P(difference) = 0.39), the RR was higher for type II diabetes mellitus with insulin use (RR = 1.28; 95% CI, 0.74-2.24) than for type II diabetes mellitus without insulin use (RR = 0.96; 95% CI, 0.64-1.43). Diabetes seemed to be more strongly associated with nonserous (RR = 1.41; 95% CI, 0.70-2.85) than serous (RR = 0.71; 95% CI, 0.41-1.23) histologic subtypes. Type II diabetes mellitus was not associated with risk of epithelial ovarian cancer, although higher risks with nonserous subtypes and among insulin users cannot be ruled out. Larger studies are needed to clarify associations of type II diabetes mellitus with or without insulin use with risk of ovarian cancer overall and by histologic subtypes. ©2012 AACR.

  3. Differences in clinical presentation between bipolar I and II disorders in the early stages of bipolar disorder: A naturalistic study.

    Science.gov (United States)

    Vinberg, Maj; Mikkelsen, Rie Lambaek; Kirkegaard, Thomas; Christensen, Ellen Margrethe; Kessing, Lars Vedel

    2017-01-15

    In a naturalistic clinical study of patients in the early stages of bipolar disorders the aim was to assess differences between patients with bipolar I (BD I) and bipolar II (BD II) disorders on clinical characteristics including affective symptoms, subjective cognitive complaints, functional level, the presence of comorbid personality disorders and coping strategies. Diagnoses were confirmed using the Structured Clinical Interview for DSM-IV Disorders. Clinical symptoms were rated with the Young Mania Rating Scale and the Hamilton Depression Rating Scale, and functional status using the Functional Assessment Short Test. Cognitive complaints were assessed using the Massachusetts General Hospital Cognitive and Physical Functioning Questionnaire, the presence of comorbid personality disorders using the Standardized Assessment of Personality - Abbreviated Scale and coping style using the Coping Inventory for Stressful Situations. In total, 344 patients were included (BD I (n=163) and BD II (n=181). Patients with BD II presented with significantly more depressive symptoms, more cognitive complaints, lower overall functioning, and a higher prevalence of comorbid personality disorders. Finally, they exhibited a trend towards using less adaptive coping styles. It cannot be omitted that some patients may have progressed from BD II to BD I. Most measures were based on patient self report. Overall, BD II was associated with a higher disease burden. Clinically, it is important to differentiate BD II from BD I and research wise, there is a need for tailoring and testing specific interventions towards BD II. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Radiation hardness studies for DEPFETs in Belle II

    International Nuclear Information System (INIS)

    Ritter, Andreas

    2014-01-01

    The study of CP violation requires dedicated detectors and accelerators. At KEK, the High Energy Accelerator Research Organization located in Tsukuba, Japan, an upgrade of the present accelerator KEKB and its detector is in progress. For this new Belle II detector, a new vertex system will be installed, consisting of a silicon strip detector (SVD) and a pixel detector (PXD). The PXD exhibits eight million pixels, each of them made of Depleted p-channel Field Effect Transistors (DEPFETs). During the operation of Belle II various machine- as well as luminosity-related background processes affect the device performance of the DEPFET through radiation damage. As a Metal-Oxide-Semiconductor (MOS) device, the DEPFET is affected by ionizing radiation damage as well as by damages to the silicon bulk itself. The major part of the radiation damage has its origin in the creation of electrons and positrons near the interaction point. Therefore, the hardness factor of electrons of relevant energy was investigated in this work. With this quantity the damage by electrons could be compared to the damage inflicted by neutrons. Neutron irradiations were performed with DEPFETs and related silicon material. The effects of leakage current increase and type inversion were studied. As the electron hardness investigation indicates, the bulk damage done to the DEPFET is small in comparison to the impact on the silicon dioxide layer of the device. Ionizing radiation results in a build-up of oxide charge, thus changing the device characteristics. Especially the threshold voltage of the DEPFET is shifted to more negative values. This shift has to be compensated during the operation of Belle II and is limited by device and system constraints, thus an overall small shift is desired. The changes in the device characteristics were investigated for the two gate electrodes of the DEPFET with respect to their biasing and production related issues. With an additional layer of silicon nitride and a

  5. EBR-II blanket fuel leaching test using simulated J-13 well water.

    Energy Technology Data Exchange (ETDEWEB)

    Fonnesbeck, J. E.

    1998-05-15

    A pulsed-flow leaching test is being conducted using three EBR-II blanket fuel segments. These samples are immersed in simulated J-13 well water. The samples are kept at a constant temperature of 90 C. Leachate is exchanged weekly and analyzed for various nuclides which are of interest from a mobility and longevity point of view. Our primary interest is in the longer-lived species such as {sup 99}Tc, {sup 237}Np, and {sup 241}Am. In addition, the behavior of U, Pu, {sup 90}Sr, and {sup 137}Cs are being analyzed. During the course of this experiment, an interesting observation has been made involving one of the samples which could indicate the possible rapid ''anoxic'' oxidation of uranium metal to UO{sub 2}.

  6. Jet Propellant (JP)-8 Fuel Evaluation Test Mk II - Reset (Mk II R) Bridge Erection Boat (BEB)

    Science.gov (United States)

    2008-10-01

    diesel engines (fig. 2 and 3) equipped with Delphi rotary fuel injection pumps. Figure 1. Mk II R BEB pushing a two-bay IRB raft. TR No. WF-E-83 2... nozzles . The new pump (serial No. 08813K7B) and gasket were installed. 24 May 07 51.0 50.4 44.9 103 Port Fuel Pump and Injectors Replaced. At the...part No. 3909356) were installed on the injector nozzles . The new pump (serial No. 59640HZB) and gasket were installed. 31 May 07 51.5 50.5 44.9 104

  7. Resonant Frequency Control For the PIP-II Injector Test RFQ: Control Framework and Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Edelen, A. L. [Colorado State U.; Biedron, S. G.; Milton, S. V.; Bowring, D.; Chase, B. E.; Edelen, J. P.; Nicklaus, D.; Steimel, J.

    2016-12-16

    For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available headroom of the RF amplifiers limits the maximum allowable detuning to 3 kHz, and the detuning is controlled entirely via thermal regulation. Fine control over the detuning, minimal manual intervention, and fast trip recovery is desired. In addition, having active control over both the walls and vanes provides a wider tuning range. For this, we intend to use model predictive control (MPC). To facilitate these objectives, we developed a dedicated control framework that handles higher-level system decisions as well as executes control calculations. It is written in Python in a modular fashion for easy adjustments, readability, and portability. Here we describe the framework and present the first control results for the PI-Test RFQ under pulsed and CW operation.

  8. EBR-II blanket fuel leaching test using simulated J-13 well water

    International Nuclear Information System (INIS)

    Fonnesbeck, J. E.

    1999-01-01

    This paper discusses the results of a pulsed-flow leaching test using simulated J-13 well water leachant. This test was performed on three blanket fuel segments from the ANL-W EBR-II nuclear reactor which were originally made up of depleted uranium (DU). This experiment was designed to mimic conditions which would exist if, upon disposal of this material in a geological repository, it came in direct contact with groundwater. These segments were contained in pressure vessels and maintained at a constant temperature of 90 C. Weekly aliquots of leachate were taken from the three vessels and replaced with an equal volume of fresh leachant. These weekly aliquots were analyzed for both 90 Sr and 137 Cs. The results of the pulsed-flow leach test showed the formation of uranium oxide (UO 2 ) and uranium hydride (UH 3 ) particulate with rapid release of the 137 Cs and 90 Sr to the leachant. On the fifth week of sampling, one of the vessels became over pressurized and vented gas when opened. The most reasonable explanation for the presence of gas in this vessel is that the unoxidized uranium metal in the blanket segment could have reacted with the surrounding water leachant to form hydrogen. However, an investigation is currently being undertaken to both qualify and quantify H 2 formation during uranium spent nuclear fuel corrosion in water

  9. The prediction of creep damage in Type 347 weld metal: part II creep fatigue tests

    International Nuclear Information System (INIS)

    Spindler, M.W.

    2005-01-01

    Calculations of creep damage under conditions of strain control are often carried out using either a time fraction approach or a ductility exhaustion approach. In part I of this paper the rupture strength and creep ductility data for a Type 347 weld metal were fitted to provide the material properties that are used to calculate creep damage. Part II of this paper examines whether the time fraction approach or the ductility exhaustion approach gives the better predictions of creep damage in creep-fatigue tests on the same Type 347 weld metal. In addition, a new creep damage model, which was developed by removing some of the simplifying assumptions that are made in the ductility exhaustion approach, was used. This new creep damage model is a function of the strain rate, stress and temperature and was derived from creep and constant strain rate test data using a reverse modelling technique (see part I of this paper). It is shown that the new creep damage model gives better predictions of creep damage in the creep-fatigue tests than the time fraction and the ductility exhaustion approaches

  10. Nuclear Technology. Course 32: Nondestructive Examination (NDE) Techniques II. Module 32-4, Operation of Magnetic Particle Test Equipment.

    Science.gov (United States)

    Groseclose, Richard

    This fourth in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II describes the specific technique variables and options which are available to the test technician, provides instructions for selecting and operating the appropriate test equipment, describes physical criteria for detectable discontinuities,…

  11. Evaluation report on CCTF Core-II reflood test second shakedown test, C2-SH2 (Run 54)

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Sugimoto, Jun; Akimoto, Hajime; Okubo, Tsutomu; Murao, Yoshio

    1985-03-01

    A low power test (the initial averaged linear power density = 1.18 kW/m) and the base case test (1.4 kW/m) were performed with the Cylindrical Core Test Facility (CCTF) at Japan Atomic Energy Research Institute, in order to study the effect of the power on the reflood phenomena. The former linear power density corresponds nearly to the scaled linear power density based on the current safety evaluation criterio. During the early period of the reflood ( 200s) the heat transfer coefficient became higher and resultantly the quench front advanced faster in the low power test. The core flooding rate was nearly identical between both tests, independently of the different power. The insensitiveness of the power to the core flooding rate was also observed in FLECHT-SET performed in the USA. A significatn large differential pressure oscillation at ECC ports was experienced in the low power test, and it may be important for the long term core cooling although it has not been taken note on the previous studies. (author)

  12. Accelerator studies at cooler rings TARN and TARN II

    International Nuclear Information System (INIS)

    Katayama, Takeshi.

    1992-07-01

    Two ion cooler rings, TARN and TARN II were constructed and operated from 1975 to 1992 at the Institute for Nuclear Study, Univ. of Tokyo, for mainly accelerator studies concerning the beam accumulation, acceleration and cooling. The main subjects performed in these facilities were; 1) beam stacking in transverse and longitudinal phase spaces, 2) stochastic momentum cooling, 3) electron cooling, 4) synchrotron acceleration and 5) slow beam extraction. In the present paper, typical experimental results on these subjects, arc described as well as the basic physical idea underlying these experimental results. The technical details are out of scope of the present paper. They can be found in the other papers refered in the concerned section in the text. (author)

  13. CiteSpace II: Idiom Studies Development Trends

    Directory of Open Access Journals (Sweden)

    Wenyu Liu Ph.D.

    2013-06-01

    Full Text Available Idioms, frequently used in daily language, are a typical metaphorical language and may be a cue to uncover the universal language processing mechanism. For the purpose of better mastery of the trends and front of idioms studies, CiteSpace II, an application designed to detect and visualize the development process within a scientific field, is adopted for comprehensive literature review. It is found that (1 idioms studies have thrived since 1990s with American scholars contributing the most, especially those from University of California; (2 suppositions on idiom comprehension mechanism have been inspired by different scholars including Lakoff, Swinney and Gibbs; (3 the exploration of the neurological bases for idiom comprehension has become the pursuit of researchers across different domains.

  14. Quantum entanglement for systems of identical bosons: II. Spin squeezing and other entanglement tests

    International Nuclear Information System (INIS)

    Dalton, B J; Goold, J; Garraway, B M; Reid, M D

    2017-01-01

    These two accompanying papers are concerned with entanglement for systems of identical massive bosons and the relationship to spin squeezing and other quantum correlation effects. The main focus is on two mode entanglement, but multi-mode entanglement is also considered. The bosons may be atoms or molecules as in cold quantum gases. The previous paper I dealt with the general features of quantum entanglement and its specific definition in the case of systems of identical bosons. Entanglement is a property shared between two (or more) quantum sub-systems. In defining entanglement for systems of identical massive particles, it was concluded that the single particle states or modes are the most appropriate choice for sub-systems that are distinguishable, that the general quantum states must comply both with the symmetrization principle and the super-selection rules (SSR) that forbid quantum superpositions of states with differing total particle number (global SSR compliance). Further, it was concluded that (in the separable states) quantum superpositions of sub-system states with differing sub-system particle number (local SSR compliance) also do not occur. The present paper II determines possible tests for entanglement based on the treatment of entanglement set out in paper I. Several inequalities involving variances and mean values of operators have been previously proposed as tests for entanglement between two sub-systems. These inequalities generally involve mode annihilation and creation operators and include the inequalities that define spin squeezing. In this paper, spin squeezing criteria for two mode systems are examined, and spin squeezing is also considered for principle spin operator components where the covariance matrix is diagonal. The proof, which is based on our SSR compliant approach shows that the presence of spin squeezing in any one of the spin components requires entanglement of the relevant pair of modes. A simple Bloch vector test for

  15. Quantum entanglement for systems of identical bosons: II. Spin squeezing and other entanglement tests

    Science.gov (United States)

    Dalton, B. J.; Goold, J.; Garraway, B. M.; Reid, M. D.

    2017-02-01

    These two accompanying papers are concerned with entanglement for systems of identical massive bosons and the relationship to spin squeezing and other quantum correlation effects. The main focus is on two mode entanglement, but multi-mode entanglement is also considered. The bosons may be atoms or molecules as in cold quantum gases. The previous paper I dealt with the general features of quantum entanglement and its specific definition in the case of systems of identical bosons. Entanglement is a property shared between two (or more) quantum sub-systems. In defining entanglement for systems of identical massive particles, it was concluded that the single particle states or modes are the most appropriate choice for sub-systems that are distinguishable, that the general quantum states must comply both with the symmetrization principle and the super-selection rules (SSR) that forbid quantum superpositions of states with differing total particle number (global SSR compliance). Further, it was concluded that (in the separable states) quantum superpositions of sub-system states with differing sub-system particle number (local SSR compliance) also do not occur. The present paper II determines possible tests for entanglement based on the treatment of entanglement set out in paper I. Several inequalities involving variances and mean values of operators have been previously proposed as tests for entanglement between two sub-systems. These inequalities generally involve mode annihilation and creation operators and include the inequalities that define spin squeezing. In this paper, spin squeezing criteria for two mode systems are examined, and spin squeezing is also considered for principle spin operator components where the covariance matrix is diagonal. The proof, which is based on our SSR compliant approach shows that the presence of spin squeezing in any one of the spin components requires entanglement of the relevant pair of modes. A simple Bloch vector test for

  16. Prairie Canal Well No. 1, Calcasieu Parish, Louisiana. Volume II. Well test data. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-01

    The following are included in appendices: field test data, field non-edited data, raw data, tentative method of testing for hydrogen sulfide in natural gas using length of stain tubes, combined sample log, report on reservoir fluids study, well test analysis, analysis of solids samples from primary zone, chemical analysis procedures, scale and corrosion evaluation, laboratory report on scale deposits, and sand detector strip charts. (MHR)

  17. Comparison of the Reynell Developmental Language Scale II and the Galker test of word-recognition-in-noise in Danish day-care children

    DEFF Research Database (Denmark)

    Lous, Jørgen; Glenn Lauritsen, Maj Britt

    2018-01-01

    Objective: To search for predictive factors for language development measured by two receptive language tests for children, the Galker test (a word-recognition-in-noise test) testing hearing and vocabulary, and the Danish version of Reynell Developmental Language Scale (2nd revision, RDLS II) test...... in terms of the degree to which variables were able to predict test scores at the age of three to five years. Methods: All children aged three and five years attending 20 day-care centres for children without cognitive development issues from the Municipality of Hillerød, Denmark, were invited......, a language comprehension test. The study analysed if information about background variables and parents and pre-school teachers was predictive for test scores; if earlier middle ear disease, actual hearing loss and tympanometry was important for language development; and if the two receptive tests differed...

  18. Coordination studies of copper(II), cobalt(II) and iron(II) with isomeric pyridyl-tetrazole ligands

    DEFF Research Database (Denmark)

    Bond, A. D.; Fleming, A.; Gaire, J.

    2012-01-01

    The reaction of 2-(2H-tetrazol-5-yl)pyridine (L1) with 1,6-dibromohexane results in formation of the isomers 2-(6 ''-bromohexyl)-(1-tetrazol-5-yl)pyridine (12) and 2-(6 ''-bromohexyl)-(2-tetrazol-5-yl)pyridine (L3). Coordination reactions of 12 and 13 with CuCl2 center dot 2H(2)O, Co(SCN)(2) and ...... conformation in its equatorial plane. Complex 5 contains water molecules coordinated to Fe(II) in the axial sites, which form hydrogen bonds to the perchlorate counter anions. (C) 2011 Elsevier Ltd. All rights reserved....

  19. Test Design Project: Studies in Test Adequacy. Annual Report.

    Science.gov (United States)

    Wilcox, Rand R.

    These studies in test adequacy focus on two problems: procedures for estimating reliability, and techniques for identifying ineffective distractors. Fourteen papers are presented on recent advances in measuring achievement (a response to Molenaar); "an extension of the Dirichlet-multinomial model that allows true score and guessing to be…

  20. Preparation and testing of a tetra-amine copper(II) chitosan bead system for enhanced phosphate remediation.

    Science.gov (United States)

    Kumar, Ilango Aswin; Viswanathan, Natrayasamy

    2018-03-01

    A tetra-amine copper(II) chitosan bead system (TAC@CS composite beads) was developed by grafting tetra-amine copper(II) (TAC) with chitosan (CS) and utilized for phosphate removal. The prepared TAC@CS composite beads possess enhanced phosphate sorption capacity (SC) of 41.42 ± 0.071 mg/g than copper grafted chitosan (Cu@CS) composite, TAC and chitosan which were found to be 37.01 ± 0.803, 33.20 ± 0.650 and 7.24 ± 0.059 mg/g respectively. In batch mode, various adsorption influencing parameters like contact time, initial phosphate concentration, solution pH, co-anions and temperature were optimized for maximum phosphate sorption. The prepared adsorbents were characterized by FTIR, XRD, UV-Visible, SEM and EDAX analysis. The adsorption isotherms and thermodynamic parameters of the adsorbent were studied. The feasible phosphate uptake mechanism of TAC@CS biocomposite beads was reported. The reusability studies of TAC@CS composite beads were carried out using NaOH as elutant. The suitability of TAC@CS composite beads at field conditions was tested with phosphate contaminated field water samples collected from nearby areas of Dindigul district. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Synthesis, characterization and biological studies of 2-(4-nitro phenylaminocarbonyl)benzoic acid and its complexes with Cr(III), Co(II), Ni(II), Cu(II) and Zn(II)

    International Nuclear Information System (INIS)

    Aqeel Ashraf, M.; Jamil Maah, M.; Yusuf, I.

    2012-01-01

    Cr(III), Co(II), Ni(II), Cu(II) and Zn(II) salts of 2-(4-nitro phenylaminocarbonyl)benzoic acid were characterized by physical, analytical and spectroscopic studies and checked for their in-vitro antimicrobial activity against three bacterial strains, Mycobacterium smegmatis (Gram +ve), Escherichia coli (Gram -ve), Pseudomonas aeuroginosa (Gram -ve) and three fungal strains, Nigrospora oryzae, Aspergillus niger and Candida albicans. The antimicrobial activities of the metal complexes - were found to be greater than those of 2-(4-nitro phenylaminocarbonyl)benzoic acid alone.

  2. Testes de toxicidade aguda através de bioensaios no extrato solubilizado dos resíduos classe II A - não inertes e classe II B - inertes Acute toxicity tests by bioassays applied to the solubilized extracts of solid wastes class II A - non inerts and class II B - inerts

    Directory of Open Access Journals (Sweden)

    Nébora Liz Vendramin Brasil Rodrigues

    2007-03-01

    Full Text Available A grande diversidade de substâncias potencialmente tóxicas contribuem para a deterioração do meio ambiente. O objetivo deste trabalho foi propor a utilização de bioensaios, através de testes de toxicidade aguda com Daphnia magna e Vibrio fischeri, como mais um parâmetro a ser analisado no extrato solubilizado dos resíduos que, segundo a NBR 10004/04 fossem classificados como classe II A - não inertes ou classe II B - inertes. Realizaram-se, também, testes de toxicidade no drenado dos aterros classe II A e II B. Verificou-se que a toxicidade foi constatada nos extratos solubilizados dos 18 resíduos analisados e que, apenas três das amostras estariam próprias para lançamento, ou seja os resíduos 04, 14 e 15. Já, a toxicidade encontrada no drenado dos aterros, ficou muito superior do que a toxicidade de cada extrato solubilizado analisado separadamente.A great diversity of substances potencially toxic contributes to the deterioration of the environment. The aim of this research was to propose the use of bioassays using Daphnia magna and Vibrio fischeri, as another parameter to be analyzed in the solubilized extraction of waste according to NBR 10004/04 and classified as class II A - non inerts or class II B - inerts. Besides, another test was performed to measure the level of toxicity in the drainage of the landfill class II A and II B. It was verified that the toxicity found in the solubilized extracts of the 18 wastes analysed.Only 3 wastes (04, 14 and 15 were within the emission limits. On the other hand the toxicity found in the drainage of the landfill, from which all the samples came from, was much higher than the individual one.

  3. Radial electrical field effects in TJ-II. (Preliminary study)

    International Nuclear Information System (INIS)

    Guasp, J.

    1996-01-01

    The influence of the radial electric field upon the neoclassical transport coefficients of TJ-II helical axis Stellarator has been calculated as well on the microwave heating stage (ECRH) as on the neutral injection one (NBI). The influence of the solutions for the self-consistent ambipolar field on confinement times and temperatures has been studied by means of a zero-dimensional energy balance. The simultaneous presence of two roots, the electronic and the ionic one, is observed for the ECRH phase, while for NBI only the ionic root appears, although with a strong field intensity that could produce a favourable effect on confinement. The interest and need of the extension of these calculations to include radial profile effects by using spatial dependent transport codes in stressed

  4. EEG, HRV and Psychological Correlates while Playing Bejeweled II: A Randomized Controlled Study.

    Science.gov (United States)

    Russoniello, Carmen V; O'Brien, Kevin; Parks, Jennifer M

    2009-01-01

    Stress related medical disorders such as cardiovascular disease, diabetes, depression, and anxiety are serious medical issues that can cause disability and death. Interventions to prevent their development and exacerbation are needed. Casual video games (CVGs) are fun, easy to play, spontaneous and tremendously popular. People report that they play these games because they decrease their stress and improve their mood. This study tested this theory by comparing people playing Bejeweled II a popular CVG with control subjects measured under similar conditions. Electroencephalographic (EEG) changes after playing Bejeweled II were consistent with increased mood and corroborated with similar findings on psychological reports. Moreover, heart rate variability (HRV) changes consistent with autonomic nervous system relaxation or decreased physical stress were also recorded. It is concluded, therefore, that playing a CVG like Bejeweled II can increase mood and decrease stress. These finding have broad implications and include the potential development of prescriptive interventions using Bejeweled II to prevent and treat stress related medical disorders. Finally, these findings demonstrate a method using EEG, HRV and psychological correlates to understand the psychophysiological or cybernetic interconnection between participant and video game.

  5. Poly (furfural-acetone as New Adsorbent for Removal of Cu(II from Aqueous Solution: Equilibrium Study

    Directory of Open Access Journals (Sweden)

    Tariq S. Najim

    2010-01-01

    Full Text Available The batch removal of Cu(II from aqueous solution using poly (furfural-acetone, (PFA as adsorbent was investigated in this study. The influences of initial Cu(II ion concentration (10 to 120 ppm, pH (4-8 and contact time have been reported. Adsorption of Cu(II is highly pH-dependent and the result indicate that the optimum pH for the removal was found to be 6. At this pH a small amount of PFA, 2 g/L, could remove as much as 97% of Cu(II from a solution of initial concentration 10 ppm. It was observed that an increase in initial concentration of Cu(II leads to decrease in percent removal of Cu(II and increase in amount of Cu(II adsorbed per unit mass of PFA. The adsorption process of Cu(II is tested with four isotherm models, Langmuir, Freundlich, Temkin and Dubinin–Radushkevich (D-R. It was found that all models were applicable and the maximum adsorption capacity was found to be 13.66 mg/g. From the isotherm constants it was confirmed that, the sorption process was physisorption.

  6. Extraction magnetically insulated diode studies on Gamble II

    International Nuclear Information System (INIS)

    Neri, J.M.; Boller, J.R.; Ottinger, P.F.; Stephanakis, S.J.; Greenly, J.

    1993-01-01

    An extraction Magnetically Insulated Diode (MID) with anode and cathode magnetic field coils has been tested on the NRL Gamble II accelerator. The purpose of the experiments is to develop an annular, intense ion beam source for testing ion beam transport physics related to light ion inertial confinement fusion. Initial experiments have been performed with surface flashover ion sources. The experimental challenge has been to obtain a tuning of the 4 magnetic field coils that results in a minimum turn-on time of the ion source and acceptable coupling to the accelerator. Results from several different geometries of magnetic field will be presented. The principal diode diagnostics are the total diode current, net ion current, and corrected diode voltage. Calculations of the magnetic field strength and geometry are performed with the ATHETA code. An active anode ion source is also under development. The initial portion of the accelerator pulse is diverted with a plasma opening switch (POS) and passed through a thin foil that will become the ion source. The foil is swiftly heated by the current pulse and gas is desorbed or diffused from the foil into the anode-cathode gap. The gas is then broken down by the current pulse, forming a dense plasma source on the anode surface. Two different foils are being used. A thin aluminum foil will work with desorbed gases, and provide a beam that is predominately protons. A hydrogen loaded titanium foil, with a paladium overcoating, will use diffused hydrogen, and produce a high purity proton beam. The net result of the POS and active anode plasma source should be much faster ion turn-on time, and better coupling of the ion source to the accelerator. Preliminary results with the active anode sources will be presented

  7. Equilibrium, thermodynamic and kinetic studies for the biosorption of aqueous lead(II), cadmium(II) and nickel(II) ions on Spirulina platensis

    Energy Technology Data Exchange (ETDEWEB)

    Seker, Ayseguel [Department of Chemistry, Izmir Institute of Technology, Urla 35430, Izmir (Turkey)], E-mail: aysegulseker@iyte.edu.tr; Shahwan, Talal [Department of Chemistry, Izmir Institute of Technology, Urla 35430, Izmir (Turkey)], E-mail: talalshahwan@iyte.edu.tr; Eroglu, Ahmet E. [Department of Chemistry, Izmir Institute of Technology, Urla 35430, Izmir (Turkey)], E-mail: ahmeteroglu@iyte.edu.tr; Yilmaz, Sinan [Department of Chemistry, Izmir Institute of Technology, Urla 35430, Izmir (Turkey)], E-mail: sinanyilmaz@iyte.edu.tr; Demirel, Zeliha [Department of Biology, Ege University, Bornova 35100, Izmir (Turkey)], E-mail: zelihademirel@gmail.com; Dalay, Meltem Conk [Department of Bioengineering, Ege University, Bornova 35100, Izmir (Turkey)], E-mail: meltemconkdalay@gmail.com

    2008-06-15

    The biosorption of lead(II), cadmium(II) and nickel(II) ions from aqueous solution by Spirulina platensis was studied as a function of time, concentration, temperature, repetitive reactivity, and ionic competition. The kinetic results obeyed well the pseudo second-order model. Freundlich, Dubinin Radushkevich and Temkin isotherm models were applied in describing the equilibrium partition of the ions. Freundlich isotherm was applied to describe the design of a single-stage batch sorption system. According to the thermodynamic parameters such as {delta}G{sup o}, {delta}H{sup o}and {delta}S{sup o} calculated, the sorption process was endothermic and largely driven towards the products. Sorption activities in a three metal ion system were studied which indicated that there is a relative selectivity of the biosorbent towards Pb{sup 2+} ions. The measurements of the repetitive reusability of S. platensis indicated a large capacity towards the three metal ions.

  8. Cooling for SC devices of test cryomodule for ADS Injector II at IMP

    Energy Technology Data Exchange (ETDEWEB)

    Wang, L.; Wang, S. Y.; Sun, S.; Wang, S. H.; Liu, Y. Y. [Shanghai Institute of Applied Physics, CAS, Shanghai 201204 (China); Guo, X. L. [JiangSu University, Zhenjiang 212013 (China)

    2014-01-29

    The superconducting half-wave resonance cavities connected in series with superconducting solenoids will be applied to the Injector II of the Accelerator Driven Sub-critical System (ADS) to be built at the Modern Physics Institute, China. A test system has been developed for the purpose of performance test of the HWR cavities as well as validating the relevant technique for cooling the cavity and the solenoids together. It mainly comprises a cryogenic valve box (TVB), a test cryomodule (TCM1) and transfer lines. The TCM1 includes one HWR cavity, two superconducting solenoids, one cold BPM and their cooling system. The design of the TCM1 cryostat was carried out by the Shanghai Institute of Applied Physics (SINAP), CAS. Both the cavity and the solenoids will work at 4.4 K by bath cooling. The fast cooling down for the cavity from around 100 K to 120 K is required to avoid degrading of the cavity performance. After cool down and before energization, the solenoids should be warmed up to above 10 K and re-cooled down for the purpose of degaussing. The TCM1 can not only be cooled by using the dewar-filling system, but also operated by the refrigerator system. For the purpose of reducing the heat loads to the cold mass at 4 K from room temperature, thermal radiation shields cooled by liquid nitrogen flowing in tubing were employed. This paper presents the design details of cooling circuits and thermal shields of the TCM1 as well as related calculations and analyses.

  9. Comparative study of adsorption properties of Turkish fly ashes II. The case of chromium (VI) and cadmium (II)

    International Nuclear Information System (INIS)

    Bayat, Belgin

    2002-01-01

    The purpose of the study described in this paper was to compare the removal of Cr(VI) and Cd(II) from an aqueous solution using two different Turkish fly ashes; Afsin-Elbistan and Seyitomer as adsorbents. The influence of four parameters (contact time, solution pH, initial metal concentration in solution and ash quality) on the removal at 20±2 deg. C was studied. Fly ashes were found to have a higher adsorption capacity for the adsorption of Cd(II) as compared to Cr(VI) and both Cr(VI) and Cd(II) required an equilibrium time of 2 h. The adsorption of Cr(VI) was higher at pH 4.0 for Afsin-Elbistan fly ash (25.46%) and pH 3.0 for Seyitomer fly ash (30.91%) while Cd(II) was adsorbed to a greater extent (98.43% for Afsin-Elbistan fly ash and 65.24% for Seyitomer fly ash) at pH 7.0. The adsorption of Cd(II) increased with an increase in the concentrations of these metals in solution while Cr(VI) adsorption decreased by both fly ashes. The lime (crystalline CaO) content in fly ash seemed to be a significant factor in influencing Cr(VI) and Cd(II) ions removal. The linear forms of the Langmuir and Freundlich equations were utilised for experiments with metal concentrations of 55±2 mg/l for Cr(VI) and 6±0.2 mg/l for Cd(II) as functions of solution pH (3.0-8.0). The adsorption of Cr(VI) on both fly ashes was not described by both the Langmuir and Freundlich isotherms while Cd(II) adsorption on both fly ashes satisfied only the Langmuir isotherm model. The adsorption capacities of both fly ashes were nearly three times less than that of activated carbon for the removal of Cr(VI) while Afsin-Elbistan fly ash with high-calcium content was as effective as activated carbon for the removal of Cd(II). Therefore, there are possibilities for use the adsorption of Cd(II) ions onto fly ash with high-calcium content in practical applications in Turkey

  10. Higher order mode damping studies on the PEP-II B-Factory RF cavity

    International Nuclear Information System (INIS)

    Rimmer, R.; Goldberg, D.; Lambertson, G.; Voelker, F.; Ko, K.; Kroll, N.; Pendleton, R.; Schwarz, H.; Adams, F.; De Jong, M.

    1992-03-01

    We describe studies of the higher-order-mode (HOM) properties of the prototype 476 MHz RF cavity for the proposed PEP-II B-Factory and a waveguide damping scheme to reduce possible HOM-driven coupled-bunch beam instability growth. Numerical studies include modelling of the HOM spectrum using MAFIA and ARGUS, and calculation of the loaded Q's of the damped modes using data from these codes and the Kroll-Yu method. We discuss briefly the experimental investigations of the modes, which will be made in a full-size low-power test cavity, using probes, wire excitation and bead perturbation methods

  11. MRP (materiel requirements planning) II implementation: a case study.

    Science.gov (United States)

    Sheldon, D

    1994-05-01

    Manufacturing resource planning (MRP II) is a powerful and effective business planning template on which to build a continuous improvement culture. MRP II, when successfully implemented, encourages a disciplined yet nonthreatening environment centered on measurement and accountability. From the education that accompanies an MRP II implementation, the employees can better understand the vision and mission of the organization. This common goal keeps everyone's energy directed toward the same final objective. The Raymond Corporation is a major materiels handling equipment manufacturer headquartered in Greene, New York, with class "A" MRP II manufacturing facilities in Greene and Brantford, Ontario and an aftermark distribution facility in East Syracuse, New York. Prior to the implementation of MRP II in its Greene plant (from 1988 through 1990) good intentions and hard work were proving to be less than necessary to compete in the global market. Certified class "A" in February 1990. The Raymond Corporation has built a world-class organization from these foundations.

  12. Study on the adsorption of Cu(II) by folic acid functionalized magnetic graphene oxide

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Cuicui [Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, University of Jinan, Jinan 250022 (China); School of Material Science and Engineering, University of Jinan, Jinan 250022 (China); Ge, Heyi, E-mail: geheyi@sina.com [Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, University of Jinan, Jinan 250022 (China); School of Material Science and Engineering, University of Jinan, Jinan 250022 (China); Zhao, Yueying [Shandong Xiaguang Industrial Co., Ltd., Jining 272000 (China); Liu, Shanshan; Zou, Yu; Zhang, Wenbo [Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, University of Jinan, Jinan 250022 (China); School of Material Science and Engineering, University of Jinan, Jinan 250022 (China)

    2017-02-01

    The folic acid functionalized magnetic graphene oxide (FA-mGO) as a new adsorbent has been synthesized in this work for the elimination of Cu(II) from waste water. The as-prepared FA-mGO was tested by SEM, TEM, particle size analyzer, FTIR, XRD, Roman spectrum, TGA and magnetic properties analyzer. Some factors, such as adsorbent dose, pH, contact time, initial concentration of adsorbate and temperature were explored. The results showed that the FA-mGO had the better adsorption performance than mGO. After 40 min, the adsorption equilibrium could be reached. Furthermore, the adsorption property obeyed the pseudo-second order kinetic model and the Temkin isotherms well. The maximum adsorption capacity was 283.29 mg/g for Cu(II) from Pseudo-second-order model at pH=5 and 318 K. The chelation action between FA and Cu(II) along with electrostatic incorporation between GO and Cu(II) determined the favourable adsorption property. Besides, thermodynamic studies results ∆G{sup 0}<0, ∆H{sup 0}>0, ∆S{sup 0}>0 suggested that the adsorption mechanism was an endothermic and spontaneous process essentially. Finally, desorption and reusability studies imply FA-mGO has an excellent reproducibility and is benefit to environmental protection and resource conservation. - Graphical abstract: Schematic illustration of preparing FA-mGO. - Highlights: • The FA-mGO was synthesized for the removal of Cu(II). • The chelation action and electrostatic incorporation determined the favourable adsorption property. • The adsorption property obeyed the pseudo-second-order and Temkin models well. • The adsorption mechanism was an endothermic and spontaneous process. • The FA-mGO has an excellent reproducibility.

  13. Synthesis, spectral characterization thermal stability, antimicrobial studies and biodegradation of starch–thiourea based biodegradable polymeric ligand and its coordination complexes with [Mn(II), Co(II), Ni(II), Cu(II), and Zn(II)] metals

    OpenAIRE

    Nahid Nishat; Ashraf Malik

    2016-01-01

    A biodegradable polymer was synthesized by the modification reaction of polymeric starch with thiourea which is further modified by transition metals, Mn(II), Co(II), Ni(II), Cu(II) and Zn(II). All the polymeric compounds were characterized by (FT-IR) spectroscopy, 1H NMR spectroscopy, 13C NMR spectroscopy, UV–visible spectra, magnetic moment measurements, thermogravimetric analysis (TGA) and antibacterial activities. Polymer complexes of Mn(II), Co(II) and Ni(II) show octahedral geometry, wh...

  14. Investigation for the sodium leak Monju. Sodium fire test-II

    International Nuclear Information System (INIS)

    Uchiyama, Naoki; Takai, Toshihide; Nishimura, Masahiro; Miyahara, Shinya; Miyake, Osamu; Tanabe, Hiromi

    2000-08-01

    As a part of the work for investigating the sodium leak accident which occurred in the Monju reactor (hereinafter referred to as Monju), sodium fire test-II was carried out using the SOLFA-1 (Sodium Leak, Fire and Aerosol) facility at OEC/PNC. In the test, the piping, ventilation duct, grating and floor liner were all full-sized and arranged in a rectangular concrete cell in the same manner as in Monju. The main objectives of the test were to confirm the leak and burning behavior of sodium from the damaged thermometer, and the effects of the sodium fire on the integrity of the surrounding structure. The main conclusions obtained from the test are shown below: (1) Burning Behavior of Leaked Sodium : Images taken with a cameras in the test reveal that in the early stages of the sodium leak, the sodium dropped down out of the flexible tube in drips. (2) Damage to the Ventilation Duct and Grating : The temperature of the ventilation duct's inner surface fluctuated between approximately 600degC and 700degC. The temperature of the grating began rising at the outset of the test, then fluctuated between roughly 600degC and 900degC. The maximum temperature was about 1000degC. After the test, damage to the ventilation duct and the grating was found. Damage to the duct was greater than that at Monju. (3) Effects on the Floor Liner : The temperature of the floor liner under the leak point exceed 1,000degC at 3 hours and 20 minutes into the test. A post test inspection of the liner revealed five holes in an area about 1m x 1m square under the leak point. There was also a decrease of the liner thickness on the north and west side of the leak point. (4) Effects on Concrete : The post test inspection revealed no surface damage on either the concrete side walls or the ceiling. However, the floor concrete was eroded to a maximum depth 8 cm due to a sodium-concrete reaction. The compressive strength of the concrete was not degraded in spite of the thermal effect. (5) Chemical

  15. Theoretical study of the magnetic behavior of hexanuclear Cu(II) and Ni(II) polysiloxanolato complexes.

    Science.gov (United States)

    Ruiz, Eliseo; Cano, Joan; Alvarez, Santiago; Caneschi, Andrea; Gatteschi, Dante

    2003-06-04

    A theoretical density functional study of the exchange coupling in hexanuclear polysiloxanolato-bridged complexes of Cu(II) and Ni(II) is presented. By calculating the energies of three different spin configurations, we can obtain estimates of the first-, second-, and third-neighbor exchange coupling constants. The study has been carried out for the complete structures of the Cu pristine cluster and of the chloroenclathrated Ni complex as well as for the hypotethical pristine Ni compound and for magnetically dinuclear analogues M(2)Zn(4) (M = Cu, Ni).

  16. Spectroscopic, thermal, catalytic and biological studies of Cu(II) azo dye complexes

    Science.gov (United States)

    El-Sonbati, A. Z.; Diab, M. A.; El-Bindary, A. A.; Shoair, A. F.; Hussein, M. A.; El-Boz, R. A.

    2017-08-01

    New complexes of copper(II) with azo compounds of 5-amino-2-(aryl diazenyl)phenol (HLn) are prepared and investigated by elemental analyses, molar conductance, IR, 1H NMR, UV-Visible, mass, ESR spectra, magnetic susceptibility measurements and thermal analyses. The complexes have a square planar structure and general formula [Cu(Ln)(OAc)]H2O. Study the catalytic activities of Cu(II) complexes toward oxidation of benzyl alcohol derivatives to carbonyl compounds were tested using H2O2 as the oxidant. The intrinsic binding constants (Kb) of the ligands (HLn) and Cu(II) complexes (1-4) with CT-DNA are determined. The formed compounds have been tested for biological activity of antioxidants, antibacterial against Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) bacteria and yeast Candida albicans. Antibiotic (Ampicillin) and antifungal against (Colitrimazole) and cytotoxic compounds HL1, HL2, HL3 and complex (1) showed moderate to good activity against S. aureus, E. coli and Candida albicans, and also to be moderate on antioxidants and toxic substances. Molecular docking is used to predict the binding between the ligands with the receptor of breast cancer (2a91).

  17. Reflood behavior at low initial clad temperature in Slab Core Test Facility Core-II

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Sobajima, Makoto; Abe, Yutaka; Iwamura, Takamichi; Ohnuki, Akira; Okubo, Tsutomu; Murao, Yoshio; Okabe, Kazuharu; Adachi, Hiromichi.

    1990-07-01

    In order to study the reflood behavior with low initial clad temperature, a reflood test was performed using the Slab Core Test Facility (SCTF) with initial clad temperature of 573 K. The test conditions of the test are identical with those of SCTF base case test S2-SH1 (initial clad temperature 1073 K) except the initial clad temperature. Through the comparison of results from these two tests, the following conclusions were obtained. (1) The low initial clad temperature resulted in the low differential pressures through the primary loops due to smaller steam generation in the core. (2) The low initial clad temperature caused the accumulated mass in the core to be increased and the accumulated mass in the downcomer to be decreased in the period of the lower plenum injection with accumulator (before 50s). In the later period of the cold leg injection with LPCI (after 100s), the water accumulation rates in the core and the downcomer were almost the same between both tests. (3) The low initial clad temperature resulted in the increase of the core inlet mass flow rate in the lower plenum injection period. However, the core inlet mass flow rate was almost the same regardless of the initial clad temperature in the later period of the cold leg injection period. (4) The low initial clad temperature resulted in the low turnaround temperature, high temperature rise and fast bottom quench front propagation. (5) In the region apart from the quench front, low initial clad temperature resulted in the lower heat transfer. In the region near the quench front, almost the same heat transfer coefficient was observed between both tests. (6) No flow oscillation with a long period was observed in the SCTF test with low initial clad temperature of 573 K, while it was remarkable in the Cylindrical Core Test Facility (CCTF) test which was performed with the same initial clad temperature. (J.P.N.)

  18. Medical information, communication, and archiving system (MICAS): Phase II integration and acceptance testing

    Science.gov (United States)

    Smith, Edward M.; Wandtke, John; Robinson, Arvin E.

    1999-07-01

    The Medical Information, Communication and Archive System (MICAS) is a multi-modality integrated image management system that is seamlessly integrated with the Radiology Information System (RIS). This project was initiated in the summer of 1995 with the first phase being installed during the first half of 1997 and the second phase installed during the summer of 1998. Phase II enhancements include a permanent archive, automated workflow including modality worklist, study caches, NT diagnostic workstations with all components adhering to Digital Imaging and Communications in Medicine (DICOM) standards. This multi-vendor phased approach to PACS implementation is designed as an enterprise-wide PACS to provide images and reports throughout our healthcare network. MICAS demonstrates that aa multi-vendor open system phased approach to PACS is feasible, cost-effective, and has significant advantages over a single vendor implementation.

  19. Evaluation report on CCTF Core-II reflood test C2-9 (Run 68)

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Iguchi, Tadashi; Okubo, Tsutomu; Murao, Yoshio; Okabe, Kazuharu; Sugimoto, Jun.

    1987-02-01

    In order to study the LPCI flow rate effect on the core cooling and system behavior, a test was performed with the LPCI flow rate of 0.025 m 3 /s, which corresponds to the flow rate in case of no pump failure in a PWR system. Through the comparisons of test results with those from the reference test with the LPCI flow rate of 0.011 m 3 /s, the following conclusions were obtained: (1) The higher LPCI flow rate resulted in the worse core-cooling in these two tests. The test results show that the lower LPCI flow rate is not necessarily a conservative assumption for the evaluation of the core cooling during the reflood phase of a PWR LOCA. (2) The worse core-cooling in the high LPCI flow rate test is attributed to the lower core-pressure than in the reference test. It is found that the lower core-pressure results from the lower pressure drop through the broken cold leg. (3) It is expected that the current evaluation model(EM) code is still conservative because it usually predicts the low pressure drop through the broken cold leg. (4) The flow oscillation in the cold leg was not significant even in the high LPCI flow rate test before the whole core quench. (author)

  20. Thermal Studies of Zn(II, Cd(II and Hg(II Complexes of Some N-Alkyl-N-Phenyl-Dithiocarbamates

    Directory of Open Access Journals (Sweden)

    Peter A. Ajibade

    2012-07-01

    Full Text Available The thermal decomposition of Zn(II, Cd(II and Hg(II complexes of N-ethyl-N-phenyl and N-butyl-N-phenyl dithiocarbamates have been studied using thermogravimetric analysis (TGA and differential scanning calorimetry (DSC. The products of the decomposition, at two different temperatures, were further characterized by scanning electron microscopy (SEM and energy-dispersive X-ray spectroscopy (EDX. The results show that while the zinc and cadmium complexes undergo decomposition to form metal sulphides, and further undergo oxidation forming metal oxides as final products, the mercury complexes gave unstable volatiles as the final product.

  1. Reproducing a Prospective Clinical Study as a Computational Retrospective Study in MIMIC-II.

    Science.gov (United States)

    Kury, Fabrício S P; Huser, Vojtech; Cimino, James J

    2015-01-01

    In this paper we sought to reproduce, as a computational retrospective study in an EHR database (MIMIC-II), a recent large prospective clinical study: the 2013 publication, by the Japanese Association for Acute Medicine (JAAM), about disseminated intravascular coagulation, in the journal Critical Care (PMID: 23787004). We designed in SQL and Java a set of electronic phenotypes that reproduced the study's data sampling, and used R to perform the same statistical inference procedures. All produced source code is available online at https://github.com/fabkury/paamia2015. Our program identified 2,257 eligible patients in MIMIC-II, and the results remarkably agreed with the prospective study. A minority of the needed data elements was not found in MIMIC-II, and statistically significant inferences were possible in the majority of the cases.

  2. Scavenger receptor AI/II truncation, lung function and COPD: a large population-based study

    DEFF Research Database (Denmark)

    Thomsen, M; Nordestgaard, B G; Tybjærg-Hansen, Anne

    2011-01-01

    The scavenger receptor A-I/II (SRA-I/II) on alveolar macrophages is involved in recognition and clearance of modified lipids and inhaled particulates. A rare variant of the SRA-I/II gene, Arg293X, truncates the distal collagen-like domain, which is essential for ligand recognition. We tested...... whether the Arg293X variant is associated with reduced lung function and risk of chronic obstructive pulmonary disease (COPD) in the general population....

  3. Unsteady Aerodynamics Experiment Phases II-IV Test Configurations and Available Data Campaigns

    Energy Technology Data Exchange (ETDEWEB)

    Simms, D. A.; Hand, M. M.; Fingersh, L. J.; Jager, D. W.

    1999-08-19

    The main objective of the Unsteady Aerodynamics Experiment is to provide information needed to quantify the full-scale three-dimensional aerodynamic behavior of horizontal axis wind turbines. To accomplish this, an experimental wind turbine configured to meet specific research objectives was assembled and operated at the National Renewable Energy Laboratory (NREL). The turbine was instrumented to characterize rotating blade aerodynamic performance, machine structural responses, and atmospheric inflow conditions. Comprehensive tests were conducted with the turbine operating in an outdoor field environment under diverse conditions. Resulting data are used to validate aerodynamic and structural dynamics models which are an important part of wind turbine design and engineering codes. Improvements in these models are needed to better characterize aerodynamic response in both the steady-state post-stall and dynamic stall regimes. Much of the effort in the earlier phase of the Unsteady Aerodynamics Experiment focused on developing required data acquisition systems. Complex instrumentation and equipment was needed to meet stringent data requirements while operating under the harsh environmental conditions of a wind turbine rotor. Once the data systems were developed, subsequent phases of experiments were then conducted to collect data for use in answering specific research questions. A description of the experiment configuration used during Phases II-IV of the experiment is contained in this report.

  4. Reactor physics tests of TRIGA Mark-II Reactor in Ljubljana

    International Nuclear Information System (INIS)

    Ravnik, M.; Mele, I.; Trkov, A.; Rant, J.; Glumac, B.; Dimic, V.

    2008-01-01

    TRIGA Mark-II Reactor in Ljubljana was recently reconstructed. The reconstruction consisted mainly of replacing the grid plates, the control rod mechanisms and the control unit. The standard type control rods were replaced by the fuelled follower type, the central grid location (A ring) was adapted for fuel element insertion, the triangular cutouts were introduced in the upper plate design. However, the main novelty in reactor physics and operational features of the reactor was the installation of a pulse rod. Having no previous operational experience in pulsing, a detailed and systematic sequence of tests was defined in order to check the predicted design parameters of the reactor with measurements. The following experiments are treated in this paper: initial criticality, excess reactivity measurements, control rod worth measurement, fuel temperature distribution, fuel temperature reactivity coefficient, pulse parameters measurement (peak power, prompt energy, peak temperature). Flux distributions in steady state and pulse mode were measured as well, however, they are treated only briefly due to the volume of the results. The experiments were performed with completely fresh fuel of 12 w% enriched Standard Stainless Steel type. The core configuration was uniform (one fuel element type, including fuelled followers) and compact (no irradiation channels or gaps), as such being particularly convenient for testing the computer codes for TRIGA reactor calculations. Comparison of analytical predictions, obtained with WIMS, SLXTUS, TRIGAP and PULSTRI codes to measured values showed agreement within the error of the measurement and calculation. The paper has the following contents: 1. Introduction; 2. Steady State Experiments; 2.1. Core loading and critical experiment; 2.2. Flux range determination for tests at zero power; 2.3. Digital reactivity meter checkout; 2.4. Control rod worth measurements; 2.5. Excess reactivity measurement; 2.6. Thermal power calibration; 2

  5. Synthesis, characterization and biological studies of 2-(4-nitrophenylamino-carbonyl)benzoic acid and its complexes with Cr(III), Co(II), Ni(II), Cu(II) and Zn(II)

    International Nuclear Information System (INIS)

    Imran, M; Nazir, S.; Latif, S.; Mahmood, Z.

    2010-01-01

    Cr(III), Co(II), Ni(II), Cu(II) and Zn(II) complexes of 2-(4-Nitrophenyl aminocarbonyl)benzoic acid were synthesized and characterized on the basis of physical, analytical and spectroscopic data. The ligands, as well as its metal complexes were checked for their in-vitro antimicrobial activity against three bacterial strains, Mycobacterium smegmatis, Escherichia coli, Pseudomonas aeuroginosa, and three fungal strains, Nigrospora oryzae, Aspergillus niger and Candida albicans. Disc diffusion method and Tube diffusion test were used for antibacterial and antifungal activities, respectively. The synthesized complexes only show significant antifungal activity but inactive for antibacterial, however, in general, the metal complexes were found to be more active against antimicrobial activities as compared to their un complexed ligand. (author)

  6. Electrodril system field test program. Phase II: Task C-1-deep drilling system demonstration. Final report for Phase II: Task C-1

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, P D

    1981-04-01

    The Electrodril Deep Drilling System field test demonstrations were aborted in July 1979, due to connector problems. Subsequent post test analyses concluded that the field replacable connectors were the probable cause of the problems encountered. The designs for both the male and female connectors, together with their manufacturing processes, were subsequently modified, as was the acceptance test procedures. A total of nine male and nine female connectors were manufactured and delivered during the 2nd Quarter 1980. Exhaustive testing was then conducted on each connector as a precursor to formal qualification testing conducted during the month of October 1980, at the Brown Oil Tool test facility located in Houston, Texas. With this report, requirements under Phase II, Task C-1 are satisfied. The report documents the results of the connector qualification test program which was successfully completed October 28, 1980. In general, it was concluded that connector qualification had been achieved and plans are now in progress to resume the field test demonstration program so that Electrodril System performance predictions and economic viability can be evaluated.

  7. Unfairness and health: evidence from the Whitehall II Study.

    Science.gov (United States)

    De Vogli, Roberto; Ferrie, Jane E; Chandola, Tarani; Kivimäki, Mika; Marmot, Michael G

    2007-06-01

    To examine the effects of unfairness on incident coronary events and health functioning. Prospective cohort study. Unfairness, sociodemographics, established coronary risk factors (high serum cholesterol, hypertension, obesity, exercise, smoking and alcohol consumption) and other psychosocial work characteristics (job strain, effort-reward imbalance and organisational justice) were measured at baseline. Associations between unfairness and incident coronary events and health functioning were determined over an average follow-up of 10.9 years. 5726 men and 2572 women from 20 civil service departments in London (the Whitehall II Study). Incident fatal coronary heart disease, non-fatal myocardial infarction and angina (528 events) and health functioning. Low employment grade is strongly associated with unfairness. Participants reporting higher levels of unfairness are more likely to experience an incident coronary event (HR 1.55, 95% CI 1.11 to 2.17), after adjustment for age, gender, employment grade, established coronary risk factors and other work-related psychosocial characteristics. Unfairness is also associated with poor physical (OR 1.46, 95% CI 1.20 to 1.77) and mental (OR 1.54, 95% CI 1.19 to 1.99) functioning at follow-up, controlling for all other factors and health functioning at baseline. Unfairness is an independent predictor of increased coronary events and impaired health functioning. Further research is needed to disentangle the effects of unfairness from other psychosocial constructs and to investigate the societal, relational and biological mechanisms that may underlie its associations with health and heart disease.

  8. Work disability following major organisational change: the Whitehall II study.

    Science.gov (United States)

    Virtanen, M; Kivimäki, M; Singh-Manoux, A; Gimeno, D; Shipley, M J; Vahtera, J; Akbaraly, T N; Marmot, M G; Ferrie, J E

    2010-05-01

    Privatisation and private sector practices have been increasingly applied to the public sector in many industrialised countries. Over the same period, long-term work disability has risen substantially. We examined whether a major organisational change--the transfer of public sector work to executive agencies run on private sector lines--was associated with an increased risk of work disability. The study uses self-reported data from the prospective Whitehall II cohort study. Associations between transfer to an executive agency assessed at baseline (1991-1994) and work disability ascertained over a period of approximately 8 years at three follow-up surveys (1995-1996, 1997-1999 and 2001) were examined using Cox proportional hazard models. In age- and sex-adjusted models, risk of work disability was higher among the 1263 employees who were transferred to an executive agency (HR 1.90, 95% CI 1.46 to 2.48) compared with the 3419 employees whose job was not transferred. These findings were robust to additional adjustment for physical and mental health and health behaviours at baseline. Increased work disability was observed among employees exposed to the transfer of public sector work to executive agencies run on private sector lines. This may highlight an unintentional cost for employees, employers and society.

  9. Template synthesis of poly aza macrocyclic copper(II) and nickel(II) complexes: Spectral characterization and antimicrobial studies

    Energy Technology Data Exchange (ETDEWEB)

    Gurumoorthy, P.; Ravichandran, J.; Kaliur Rahiman, A. [The New College, Chennai (India); Karthikeyan, N.; Palani, P. [Univ. of Madras, Chennai (India)

    2012-07-15

    The template synthesis of copper(II) and nickel(II) complexes derived from 2,6-diformyl-4-methylphenol with diethylenetriamine or 1,2-bis(3-amino propylamino)ethane produce the 12-membered N{sub 3}O and 17-membered N{sub 4}O macrocyclic complexes, respectively. The geometry of the complexes has been determined with the help of electronic and EPR spectroscopic values and found to be five coordinated square pyramidal and, six coordinated distorted tetragonal for 12-membered and 17-membered macrocyclic complexes, respectively. Electrochemical studies of the mononuclear N{sub 3}O and N{sub 4}O copper(II) complexes show one irreversible one electron reduction wave at E{sup pc} = .1.35 and .1.15 V respectively, and the corresponding nickel(II) complexes show irreversible one-electron reduction wave at E{sup pc} = .1.25 and .1.22 V, respectively. The nickel(II) complexes show irreversible one-electron oxidation wave at Epa = +0.84 and +0.82 V, respectively. All the complexes were evaluated for in vitro antimicrobial activity against the human pathogenic bacteria and fungi.

  10. Laboratory test differences associated with HTLV-I and HTLV-II infection

    NARCIS (Netherlands)

    Murphy, EL; Glynn, S; Watanabe, K; Fridey, J; Sacher, R; Schreiber, G; Luban, N

    1998-01-01

    Reports of laboratory abnormalities associated with HTLV-I and HTLV-II infection are inconsistent. We assessed complete blood counts and selected serum chemistry measures at enrollment in a cohort of 153 HTLV-I-seropositive, 386 HTLV-II-seropositive, and 795 HTLV-seronegative blood donors. Linear

  11. Test Review: Review of the Wechsler Abbreviated Scale of Intelligence, Second Edition (WASI-II)

    Science.gov (United States)

    McCrimmon, Adam W.; Smith, Amanda D.

    2013-01-01

    The Wechsler Abbreviated Scale of Intelligence, Second Edition (WASI-II; Wechsler, 2011), published by Pearson, is a newly updated abbreviated measure of cognitive intelligence designed for individuals 6 to 90 years of age. Primarily used in clinical, psychoeducational, and research settings, the WASI-II was developed to quickly and accurately…

  12. Design and testing of an electron Bernstein wave emission radiometer for the TJ-II Stellarator

    International Nuclear Information System (INIS)

    Caughman, J.B.O.; Rasmussen, D.A.; Carter, M.C.; Wilgen, J.B.; Cappa, A.; Castejon, F.; Fernandez, A.

    2005-01-01

    Efficient Electron Bernstein wave (EBW) mode conversion is important for heating dense plasmas in TJ-II. The O-X-B mode conversion scenario is being considered for heating plasmas with densities over 1,3 x 10 19 m -3 , which will be very interesting to study high-density physics and for heating NBI plasmas. Measurement of the thermal EBW emission from the plasma allows the EBW mode conversion efficiency to be determined, and also has the potential to offer a diagnostic for measuring electron temperature profile evolution in overdense plasmas. A dual-polarized quad-ridged broadband horn with a focusing lens will be used to measure the EBW emission at 28 GHz on TJ-II. A focused beam is needed to achieve efficient coupling at the mode conversion layer. Emission from the plasma is reflected from a steerable internal mirror, propagates through a glass lens, and is focused on the horn. The field pattern from the horn-lens combination has been measured as a function of horn-lens spacing and lens focal length with a 3-D scanning system in an effort to minimize the beam waist at the plasma edge. Beam waist sizes have been measured at distances of up to 80 cm from the lens. Details of the experimental results and future plans will be presented. [Oak Ridge National Laboratory is managed by UT-Battelle, LLC, for the U.S. Dept. of Energy under contract DE-AC05-00OR22725. A part of this work is performed under support of Spanish 'Subdireccion General de Proyectos de Investigacion, Ministerio de Educacion y Ciencia' with reference ENE2004-06957]. (author)

  13. Adsorption study of copper (II) by chemically modified orange peel

    International Nuclear Information System (INIS)

    Feng Ningchuan; Guo Xueyi; Liang Sha

    2009-01-01

    An adsorbent, the chemically modified orange peel, was prepared from hydrolysis of the grafted copolymer, which was synthesized by interaction of methyl acrylate with cross-linking orange peel. The presence of poly (acrylic acid) on the biomass surface was verified by infrared spectroscopy (IR), scanning electron microscopy (SEM) and thermogravimetry (TG). Total negative charge in the biomass surface and the zeta potentials were determined. The modified biomass was found to present high adsorption capacity and fast adsorption rate for Cu (II). From Langmuir isotherm, the adsorption capacity for Cu (II) was 289.0 mg g -1 , which is about 6.5 times higher than that of the unmodified biomass. The kinetics for Cu (II) adsorption followed the pseudo-second-order kinetics. The adsorbent was used to remove Cu (II) from electroplating wastewater and was suitable for repeated use for more than four cycles.

  14. EPICOR-II: a field leaching test of solidified radioactively loaded ion exchange resin

    International Nuclear Information System (INIS)

    Davis, E.C.; Marshall, D.S.; Todd, R.A.; Craig, P.M.

    1986-08-01

    As part of an ongoing research program investigating the disposal of radioactive solid wastes in the environment' the Oak Ridge National Laboratory (ORNL) is participating with Argonne National Laboratory, the Idaho National Engineering Laboratory, and the Nuclear Regulatory Commission in a study of the leachability of solidified EPICOR-II ion-exchange resin under simulated disposal conditions. To simulate disposal, a group of five 2-m 3 soil lysimeters has been installed in Solid Waste Storage Area Six at ORNL, with each lysimeter containing a small sample of solidified resin at its center. Two solidification techniques are being investigated: a Portland cement and a vinyl ester-styrene treatment. During construction, soil moisture temperature cells were placed in each lysimeter, along with five porous ceramic tubes for sampling water near the waste source. A meteorological station was set up at the study site to monitor climatic conditions (primarily precipitation and air temperature), and a data acquisition system was installed to keep daily records of these meteorological parameters as well as lysimeter soil moisture and temperature conditions. This report documents the first year of the long-term field study and includes discussions of lysimeter installation, calibration of soil moisture probes, installation of the site meteorological station, and the results of the first-quarter sampling for radionuclides in lysimeter leachate. In addition, the data collection and processing system developed for this study is documented, and the results of the first three months of data collection are summarized in Appendix D

  15. Infrared study of seven possible compact H II regions

    International Nuclear Information System (INIS)

    Sibille, F.; Lunel, M.; Bergeat, J.

    1976-01-01

    We report observations of seven possible compact H II regions in the infrared with the hydrogen spectrum in order to derive extinction and emission measures. The emission measure is compared with available radio data. For two sources, agreement is found between radio and infrared data. Infrared excess is found in four sources, its origin is discussed. Two sources cannot be interpreted as compact H II regions. (orig.) [de

  16. Evaluation report on CCTF core-II reflood test C2 - 8 (Run 67)

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Iguchi, Tadashi; Okubo, Tsutomu; Murao, Yoshio; Okabe, Kazuharu; Sugimoto, Jun.

    1987-01-01

    In order to study the system pressure effect of the core cooling and flow behavior during the reflood phase of a PWR LOCA, a test was performed with CCTF under the system pressure pf 0.15 MPa as a counterpart test of the CCTF test C2-1 (system pressure 0.42 MPa) and the CCTF test C2-4 (system pressure 0.20 MPa). Through the comparisons of results from these three tests, the following conclusions were obtained: (1) The higher system pressure resulted in the lower temperature rise, the shorter turnaround time and the shorter quench time as observed in the CCTF Core-I system pressure effect tests. (2) The higher system pressure resulted in higher core water head, higher upper plenum water head, higher mass flow rate through the primary loops. On the other hand, the higher system pressure resulted in lower downcomer water head and lower pressure drop through the primary loops and the broken cold leg. These system pressure effects on the flow behavior in the primary system are almost the same as observed in the system pressure effect tests in the CCTF Core-I test series. (3) Before the mixture level in the upper plenum reached the level of the hot leg nozzle, the loop flow resistance coefficient of the intact loops was nearly constant regardless of the system pressure. After the mixture level reached the level of the hot leg nozzle, the loop flow resistance coefficient was increased due to the water accumulation in the hot leg piping and the inlet plenum of the steam generator in these tests. (J.P.N.)

  17. Disturbances to metal partitioning during toxicity testing of iron(II)-rich estuarine pore waters and whole sediments.

    Science.gov (United States)

    Simpson, Stuart L; Batley, Graeme E

    2003-02-01

    Metal partitioning is altered when suboxic estuarine sediments containing Fe(II)-rich pore waters are disturbed during collection, preparation, and toxicity testing. Experiments with model Fe(II)-rich pore waters demonstrated the rates at which adsorptive losses of Cd, Cu, Ni, Mn, Pb, and Zn occur upon exposure to air. Experiments with Zn-contaminated estuarine sediments demonstrated large and often unpredictable changes to metal partitioning during sediment storage, removal of organisms, and homogenization before testing. Small modifications to conditions, such as aeration of overlying waters, caused large changes to the metal partitioning. Disturbances caused by sediment collection required many weeks for reestablishment of equilibrium. Bioturbation by benthic organisms led to oxidation of pore-water Fe(II) and lower Zn fluxes because of the formation of Fe hydroxide precipitates that adsorb pore-water Zn. For five weeks after the addition of organisms to sediments, Zn fluxes increased slowly as the organisms established themselves in the sediments, indicating that the establishment of equilibrium was not rapid. The results are discussed in terms of the dynamic nature of suboxic, Fe(II)-rich estuarine sediments, how organisms perturb their environment, and the importance of understanding chemistry in toxicity testing with whole sediments or pore water. Recommendations are provided for the handling of sediments for toxicity testing.

  18. ROLE OF IRON (II, III) HYDROXYCARBONATE GREEN RUST IN ARSENIC REMEDIATION USING ZEROVALENT IRON IN COLUMN TESTS

    Science.gov (United States)

    We examined corrosion products of zerovalent iron (Peerless iron) that was used in three column tests for removing arsenic under dynamic flow conditions with and without added phosphate and silicate. Iron(II, III) hydroxycarbonate and magnetite were major iron corrosion products...

  19. Computer augumented modelling studies of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II complexes of L-glutamic acid in 1,2-propanediol–water mixtures

    Directory of Open Access Journals (Sweden)

    MAHESWARA RAO VEGI

    2008-12-01

    Full Text Available Chemical speciation of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II complexes of L-glutamic acid was studied at 303 K in 0–60 vol. % 1,2-propanediol–water mixtures, whereby the ionic strength was maintained at 0.16 mol dm-3. The active forms of the ligand are LH3+, LH2 and LH–. The predominant detected species were ML, ML2, MLH, ML2H and ML2H2. The trend of the variation in the stability constants with changing dielectric constant of the medium is explained based on the cation stabilizing nature of the co-solvents, specific solvent–water interactions, charge dispersion and specific interactions of the co-solvent with the solute. The effect of systematic errors in the concentrations of the substances on the stability constants is in the order alkali > > acid > ligand > metal. The bioavailability and transportation of metals are explained based on distribution diagrams and stability constants.

  20. Natural decay series radionuclide studies at the Needle's Eye Natural Analogue Site, II, 1989-1991

    International Nuclear Information System (INIS)

    MacKenzie, A.B.; Whitton, A.M.; Shimmield, T.M.; Jemielita, R.A.; Scott, R.D.; Hooker, P.J.

    1991-12-01

    HMIP has a research programme investigating some naturally radioactive sites as geochemical analogues of radionuclide migration. The objective is to test thermodynamic databases and computer codes used for modelling radionuclide migration under environmental conditions. This report describes the study of transport and retardation processes affecting natural radionuclides, mainly uranium (U), in the vicinity of pitchblende veins in the cliff at Needle's Eye on the Solway Coast, SW Scotland. The natural decay series results from this study have been used to develop a well constrained geochemical model within which the codes can be tested. A conceptual geochemical model for the behaviour of U at the site was developed in stage I of the study; work in stage II is concerned with improving the information available on the U source term, groundwater chemistry, U aqueous phase specification, U retardation by fracture-lining minerals during fissure flow of groundwater, U-organic associations and loss of U from the site by stream drainage. (author)

  1. Studies of variability in the PTEN gene among Danish caucasian patients with Type II diabetes mellitus

    DEFF Research Database (Denmark)

    Hansen, L; Jensen, J N; Ekstrøm, C T

    2001-01-01

    Phosphatase and tensin homologue deleted from chromosome ten (PTEN) has recently been characterized as a novel member in the expanding network of proteins regulating the intracellular effects of insulin. By dephosphorylation of phosphatidyl-inositol-(3, 4, 5)-trisphosphate (PIP3) the PTEN protein...... regulates the insulin-dependent phosphoinositide 3-kinase (PI3K) signalling cassette and accordingly might function as a regulator of insulin sensitivity in skeletal muscle and adipose tissue. In this study we tested PTEN as a candidate gene for insulin resistance and late-onset Type II (non...

  2. Conceptual studies of plasma engineering test facility

    International Nuclear Information System (INIS)

    Hiraoka, Toru; Tazima, Teruhiko; Sugihara, Masayoshi; Kasai, Masao; Shinya, Kichiro

    1979-04-01

    Conceptual studies have been made of a Plasma Engineering Test Facility, which is to be constructed following JT-60 prior to the experimental power reactor. The physical aim of this machine is to examine self-ignition conditions. This machine possesses all essential technologies for reactor plasma, i.e. superconducting magnet, remote maintenance, shielding, blanket test modules, tritium handling. Emphasis in the conceptual studies was on structural consistency of the machine and whether the machine would be constructed practically. (author)

  3. Efficiency of histidine rich protein II-based rapid diagnostic tests for monitoring malaria transmission intensities in an endemic area

    Science.gov (United States)

    Modupe, Dokunmu Titilope; Iyabo, Olasehinde Grace; Oladoke, Oladejo David; Oladeji, Olanrewaju; Abisola, Akinbobola; Ufuoma, Adjekukor Cynthia; Faith, Yakubu Omolara; Humphrey, Adebayo Abiodun

    2018-04-01

    In recent years there has been a global decrease in the prevalence of malaria due to scaling up of control measures, hence global control efforts now target elimination and eradication of the disease. However, a major problem associated with elimination is asymptomatic reservoir of infection especially in endemic areas. This study aims to determine the efficiency of histidine rich protein II (HRP-2) based rapid diagnostic tests (RDT) for monitoring transmission intensities in an endemic community in Nigeria during the pre-elimination stage. Plasmodium falciparum asymptomatic malaria infection in healthy individuals and symptomatic cases were detected using HRP-2. RDT negative tests were re-checked by microscopy and by primer specific PCR amplification of merozoite surface protein 2 (msp-2) for asexual parasites and Pfs25 gene for gametocytes in selected samples to detect low level parasitemia undetectable by microscopy. The mean age of the study population (n=280) was 6.12 years [95% CI 5.16 - 7.08, range 0.5 - 55], parasite prevalence was 44.6% and 36.3% by microscopy and RDT respectively (p =0.056). The parasite prevalence of 61.5% in children aged >2 - 10 years was significantly higher than 3.7% rate in adults >18years (p malaria in endemic areas.

  4. Experimental study of impurity production in the Tokapole II tokamak

    International Nuclear Information System (INIS)

    Brickhouse, N.S.

    1984-01-01

    The release mechanism for low-Z impurities in Tokapole II has been characterized through impurity doping and isotopic exchange experiments. The desorption mechanism responsible for the low-Z impurity concentrations during the rise phase of the plasma current depends on the mass of the plasma ions. Doping with small amounts of any gas studied (H 2 , D 2 , He, N 2 , O 2 , Ne, Ar, Kr, and Xe) increases the early-time radiation of O, C, and N. For exotic gas doping this increase is linear with the dopant concentration, and proportional to the mass of the dopant, as expected for a momentum transfer process. Isotopic exchange experiments confirm the mass-dependence of oxygen production. A time-dependent coronal model is compared with the vacuum ultraviolet spectroscopic signals of the ionizing oxygen. The quantity sigma/tau (desorption cross section divided by particle confinement time) is determined to be 4 x 10 13 cm 2 /msec. The oxygen influx has a large peak early in the start-up

  5. Pulse radiolysis study of zinc(II)-insulin

    Energy Technology Data Exchange (ETDEWEB)

    Elliot, A J; Wilkinson, F; Armstrong, D A [Calgary Univ., Alberta (Canada). Dept. of Chemistry

    1980-07-01

    Reactions of e/sup -/sub(aq) with zinc(II)-insulin at pH 6.6 and 9.0 yielded relatively low disulphide anion absorptions, suggesting e/sup -/sub(aq) reacts at other sites than S-S. A similar conclusion was reached for the reaction of COsub(./2) where an even lower yield of disulphide anion was found. However, here the disulphide anion yield increased with 'prepulsing'. Simultaneously the rate constant decreased, implying that a more reactive site was 'cleaned up'. While no reaction of Brsub(./2) with insulin was observed, both OH and Clsub(./2) reacted rapidly and predominantly at the tyrosine residues. The second order rate constants, calculated in terms of insulin monomer concentrations, are reported for e/sup -/sub(aq) COsub(./2) and Clsub(./2). The transient spectra qualitatively support evidence regarding the accessibility of S-S bonds and tyrosine residues in the various forms of insulin as predicted from earlier studies.

  6. Australian Biology Test Item Bank, Years 11 and 12. Volume II: Year 12.

    Science.gov (United States)

    Brown, David W., Ed.; Sewell, Jeffrey J., Ed.

    This document consists of test items which are applicable to biology courses throughout Australia (irrespective of course materials used); assess key concepts within course statement (for both core and optional studies); assess a wide range of cognitive processes; and are relevant to current biological concepts. These items are arranged under…

  7. An introduction to testing techniques in the Intelsat TDMA/DSI system. II - Satellite system operations guide (SSOG) tests

    Science.gov (United States)

    Colby, R. J.; Parthasarathy, R.; Stimson, A. L.

    1983-12-01

    The test methods and procedures of the Intelsat TDMA/DSI SSOG are summarized. The overall structure of the SSOG is outlined, and the operational procedures to be followed for joining a new terminal to the system and for normal operations are reviewed, with an emphasis on the roles of the IOC and the TDMA reference and monitoring stations. The testing philosophy (based on minimal interruptions) and the star-test method are explained and illustrated with diagrams, and the test procedures are examined, including modem tests, electrical-path-length equalization, RF/IF downchain tests, protocol tests, nontransmitting protocol tests, IF/RF upchain tests, transmitting protocol tests, baseband tests, and orderwire lineups. The fundamental access discipline of the TDMA system is presented in an appendix.

  8. Synthesis and structural characterization of nickel(II), cobalt(II), Zinc(II), manganese(II), cadmium(II) and uranium(VI) complexes of α-oximinoacetoacet-o/p-anisidide thiosemicarbazone

    International Nuclear Information System (INIS)

    Patel, P.S.; Patel, M.M.; Ray, R.M.

    1993-01-01

    A few metal complexes of α-oximinoacetoacet-o/p-anisidide thiosemicarbazones (OAOATS)/(OAPATS) with Ni(II), Co(II), Zn(II), Mn(II), Hg(II), Cd(II) and UO 2 (II) have been prepared and characterized by elemental analyses, conductivity, differential scanning calorimetry study, thermogravimetric analyses and infrared and electronic spectral measurements in conjunction with magnetic susceptibility measurements at room temperature. They have also been tested for their antimicrobial activities. (author). 24 refs., 2 tabs

  9. Design report for an annular fuel element for accommodation of a carbide test bundle on the ring position of the KNK II/2 test zone

    International Nuclear Information System (INIS)

    Haefner, H.E.

    1982-03-01

    This report describes an annular oxide element with Mark II rods for accommodation of a 19-pin carbide test bundle on position 201 in the test zone of the second core of KNK II as well as its behavior during the period of operation. The ring element comprises within a driver wrapper in three rows of pins 102 fuel pins of 7.6 mm diameter and six structural rods for fixing the spark eroded spacers. The report deals with the ring element with its individual components fuel rod, bundle, wrappers, head and foot and describes methods, criteria and results concerning the design. The carbide test bundle to be accommodated by the annular carrier element will be treated in a separate report. The loadability of the annular element with its components is demonstrated by generally valid standards for strength criteria

  10. Modulus of elasticity, creep and shrinkage of concrete, phase II : part 1, creep study, final report.

    Science.gov (United States)

    2009-10-01

    A laboratory testing program was performed to evaluate the physical and mechanical properties of typical Class II, IV, V, and VI concrete mixtures made with a Miami Oolite limestone, a Georgia granite, and a lightweight aggregate Stalite, including c...

  11. Proton nuclear magnetic resonance and spectrophotometric studies of nickel(II)-iron(II) hybrid hemoglobins

    International Nuclear Information System (INIS)

    Shibayama, N.; Inubushi, T.; Morimoto, H.; Yonetani, T.

    1987-01-01

    Ni(II)-Fe(II) hybrid hemoglobins, α(Fe) 2 β(Ni) 2 and α(Ni) 2 β(Fe) 2 , have been characterized by proton nuclear magnetic resonance with Ni(II) protoporphyrin IX (Ni-PP) incorporated in apoprotein, which serves as a permanent deoxyheme. α(Fe) 2 β(Ni) 2 , α(Ni) 2 β(Fe) 2 , and NiHb commonly show exchangeable proton resonances at 11 and 14 ppm, due to hydrogen-bonded protons in a deoxy-like structure. Upon binding of carbon monoxide (CO) to α(Fe) 2 β(Ni) 2 , these resonances disappear at pH 6.5 to pH 8.5. On the other hand, the complementary hybrid α(Ni) 2 β(Fe-CO) 2 showed the 11 and 14 ppm resonances at low pH. Upon raising pH, the intensities of both resonances are reduced, although these changes are not synchronized. Electronic absorption spectra and hyperfine-shifted proton resonances indicate that the ligation of CO in the β(Fe) subunits induced changes in the coordination and spin states of Ni-PP in the α subunits. In a deoxy-like structure, the coordination of Ni-PP in the α subunits is predominantly in a low-spin (S = 0) four-coordination state, whereas in an oxy-like structure the contribution of a high-spin (S = 1) five-coordination state markedly increased. Ni-PP in the β subunits always takes a high-spin five-coordination state regardless of solution conditions and the state of ligation in the partner α(Fe) subunits. In the β(Ni) subunits, a significant downfield shift of the proximal histidyl N/sub δ/H resonance and a change in the absorption spectrum of Ni-PP were detected, upon changing the quaternary structure of the hybrid. The chemical shifts were analyzed in terms of the E11-Val methyls vs. the porphyrin rings in hybrid Hbs

  12. Extraction studies of Cd(II), Cu(II), Mn(II), Ni(II) and Zn(II) using N, N', N, N' -Bis((2-hydroxy-3,5-di-tert-butylbenzyl) (2-pyridylmethyl)) -ethylenediamine as a novel ligand

    International Nuclear Information System (INIS)

    Laus, R.; Anjos, A.D.; Naves, A.

    2008-01-01

    In the present study, the use of N,N',N,N'-bis((2-hydroxy-3,5-di-tert-butylbenzyl) (2- pyridylmethyl))-ethylenediamine (H2L) as ligand was evaluated in the liquid-liquid (water- chloroform) extraction of Cd(II), Cu(II), Mn(II), Ni(II) and Zn(II). Experiments were carried out to determine the pH for maximum extraction for each metal ion by ligand, maximum extraction capacity, extraction kinetics and extraction selectivity. The results revealed that the extraction of metal ions is dependent on the pH: maximum extraction maximum was obtained in the pH range of 4.5 - 6.0 for Cu(II) and 8.0 - 9.0 for Zn(II). Cd(II) and Mn(II) were best extracted at pH 9.0 and Ni(II) at 10.0. The ligand H2L was effective for the extraction of Cd(II), Cu(II) and Zn(II) (extraction efficient, %E equal 100%), whereas %E of 76% and 23.5% were observed for Mn(II) and Ni(II), respectively. The ligand presented high selectivity for the extraction of Cu(II) at pH 4.0. (author)

  13. Evaluation report on CCTF core-II reflood test C2-6 (Run 64)

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Iguchi, Tadashi; Sugimoto, Jun; Okubo, Tsutomu; Murao, Yoshio; Okabe, Kazuharu.

    1985-03-01

    In order to evaluate the effect of the radial power profile on the system behavior and the core thermal hydraulic behavior during the reflood phase of a PWR LOCA, a test was performed using the Cylindrical Core Test Facility(CCTF) with the flat radial power profile. The test was conducted with the same total core power as that of the steep radial power test C2-5(Run 63). Through the comparisons of the results from these two tests, the following conclusions were obtained: (1) The radial power profile in the core has weak effect on the thermal hydraulic behavior in the primary system except the core. (2) Almost the same differential pressure was observed at various elevations in the periphery of the core regardless of different radial power profile. The result suggests that the core differential pressure is determined mainly by the total power and the total stored energy rather than by the local power and the local stored energy. (3) The test results support the single channel core model with the average power rod used in the reactor safety analysis codes such as REFLA-1DS, WREM for the evaluation of the overall system behavior. (4) In the steep radial power test, the heat transfer coefficient in the central(high power) region was higher than that in the peripheral(low power) region. The tendency was not explained by the estimation with the heat transfer correlation developed by Murao and Sugimoto assuming that the void fraction was uniform in a horizontal cross section. It is necessary to study more the dependency of core heat transfer on the radial power profile in the wide core. (author)

  14. Test of Topmetal-II{sup −} in liquid nitrogen for cryogenic temperature TPCs

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Shuguang; Fan, Yan; An, Mangmang; Chen, Chufeng; Huang, Guangming; Liu, Jun; Pei, Hua; Sun, Xiangming, E-mail: xmsun@phy.ccnu.edu.cn; Yang, Ping; Wang, Dong; Xiao, Le; Wang, Zhen; Wang, Kai; Zhou, Wei

    2016-09-11

    Topmetal-II{sup −} is a highly pixelated direct charge sensor that contains a 72×72 pixel array of 83 μm pitch size. The key feature of Topmetal-II{sup −} is that it can directly collect charges via metal nodes of each pixel to form two-dimensional images of charge cloud distributions. Topmetal-II{sup −} was proved to measure charged particles without amplification at room temperature. To measure its performance at cryogenic temperature, a Topmetal-II{sup −} sensor is embedded into a liquid nitrogen dewar. The results presented in this paper show that Topmetal-II{sup −} can also operate well at this low temperature with a noise (ENC) of 12 e{sup −} lower than that at room temperature (13 e{sup −}). From the noise perspective, Topmetal-II{sup −} is a promising candidate for the next generation readout of liquid argon and xenon time projection chamber (TPC) used in experiments searching for neutrinoless double beta decay and dark matter.

  15. Frailty Testing Pilot Study: Pros and Pitfalls.

    Science.gov (United States)

    Adlam, Taylor; Ulrich, Elizabeth; Kent, Missy; Malinzak, Lauren

    2018-02-01

    Frailty can be defined as an inflammatory state with a loss of physiologic reserve in multiple systems that manifests as a decreased ability to respond to stressors that ultimately leads to an increased risk of adverse outcomes. The aim of this study was to determine the ease of frailty testing in a pre-kidney transplant clinic and the resources required to do so. A secondary goal was to better understand the utility of frailty testing when evaluating potential kidney transplant recipients. Frailty testing was conducted at a pre-kidney transplant clinic in three phases using Fried's frailty phenotype (shrinking, exhaustion, low physical activity, slowness, and grip strength). A total of 132 frailty tests were completed on 128 patients. Frail patients had significantly higher rates of shrinking (26% vs. 8.5%, P testing was most complete when an examiner dedicated to frailty testing performed the testing. Frailty testing is feasible to complete in a pre-transplant clinic with an appropriate investment in personnel and resources.

  16. Development of optimized advanced austenitic steels (II). Evaluation of out-of-pile testing results of the test fuel claddings

    Energy Technology Data Exchange (ETDEWEB)

    Uwaba, Tomoyuki; Mizuta, Shunji; Ukai, Shigeharu [Japan Nuclear Cycle Development Inst., Oarai, Ibaraki (Japan). Oarai Engineering Center

    2000-03-01

    14Cr-25Ni optimized advanced austenitic steels have been developed to improve the swelling resistance of 15Cr-20Ni austenitic stainless steels used for FBR fuel cladding. In this improvement, Ti, Nb, V and P were dissolved into 14Cr-25Ni matrix by means of the high-temperature solution treatment to make finely distributed and stabilized precipitates in the operation. Furthermore, at the final stage of cold-working, cold-working level increased and residual stress was reduced. In this study, as fabricated microstructure observation, solubility of alloying elements and grain size test in the manufacturing process were evaluated. Following results were obtained. (1) Spherical precipitates were observed in the grain. Most of them were identified as complexed carbide-nitride [Ti,Nb(C,N)] by EDX analysis. (2) The dissolved percentages of Ti and Ni in the matrix were about 70% and 30% respectively. Undissolved Ti and Nb may react with undissolved carbon and precipitate as MC carbides. (3) High-temperature solution treatment is effective for the sufficient solubility of alloying elements, but it is likely to induce very large grains, which is the cause of defective signal in the ultrasonic alloy testing. The results of the grain size test showed that the large grain size is reduced in low Nb (0.1wt%) alloy compared with the standard alloy (0.2wt% Nb), and the effectiveness for the grain size control by reducing the Nb content was confirmed. Also, it was suggested that the intermediate heat treatment and cold work conditions would possibly avoid the occurrence of the large grain at the final heat treatment. (author)

  17. Optimized Gen-II FeCrAl cladding production in large quantity for campaign testing

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Yukinori [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sun, Zhiqian [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pint, Bruce A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Terrani, Kurt A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-06-03

    There are two major objectives in this report; (1) to optimize microstructure control of ATF FeCrAl alloys during tube drawing processes, and (2) to provide an update on the progress of ATF FeCrAl tube production via commercial manufacturers. Experimental efforts have been made to optimize the process parameters balancing the tube fabricability, especially for tube drawing processes, and microstructure control of the final tube products. Lab-scale sheet materials of Gen II FeCrAl alloys (Mo-containing and Nb-containing FeCrAl alloys) were used in the study, combined with a stepwise warm-rolling process and intermediate annealing, aiming to simulate the tube drawing process in a commercial tube manufacturer. The intermediate annealing at 650ºC for 1h was suggested for the tube-drawing process of Mo-containing FeCrAl alloys because it successfully softened the material by recovering the work hardening introduced through the rolling step, without inducing grain coarsening due to recrystallization. The final tube product is expected to have stabilized deformed microstructure providing the improved tensile properties with sufficient ductility. Optimization efforts on Nb-containing FeCrAl alloys focused on the effect of alloying additions and annealing conditions on the stability of deformed microstructure. Relationships between the second-phase precipitates (Fe2Nb-Laves phase) and microstructure stability are discussed. FeCrAl tube production through commercial tube manufacturers is currently in progress. Three different manufacturers, Century Tubes, Inc. (CTI), Rhenium Alloys, Inc. (RAI), and Superior Tube Company, Inc. (STC), are providing capabilities for cold-drawing, warm-drawing, and HPTR cold-pilgering, respectively. The first two companies are currently working on large quantity tube production (expected 250 ft length) of Gen I model FeCrAl alloy (B136Y3, at CTI) and Gen II (C35M4, at RAI), with the process parameters obtained from the experimental

  18. High performance inboard shield design for the compact TIBER-II test reactor: Appendix A-2

    International Nuclear Information System (INIS)

    El-Guebaly, L.A.; Sviatoslavsky, I.N.

    1987-01-01

    The compactness of the TIBER-II reactor has placed a premium on the design of a high performance inboard shield to protect the inner legs of the toroidal field (TF) coils. The available space for shield is constrained to 48 cm and the use of tungsten is mandatory to protect the magnet against the 1.53 MW/m 2 neutron wall loading. The primary requirement for the shield is to limit the fast neutron fluence to 10 19 n/cm 2 . In an optimization study, the performance of various candidate materials for protecting the magnet was examined. The optimum shield consists of a 40 cm thick W layer, followed by an 8 cm thick H 2 O/LiNO 3 layer. The mechanical design of the shield calls for tungsten blocks within SS stiffened panels. All the coolant channels are vertical with more of them in the front where there is a high heat load. The coolant pressure is 0.2 MPa and the maximum structural surface temperature is 0 C. The effects of the detailed mechanical design of the shield and the assembly gaps between the shield sectors on the damage in the magnet were analyzed and peaking factors of ∼2 were found at the hot spots. 2 refs., 6 figs., 2 tabs

  19. Interaction of Zn(II) with hematite nanoparticles and microparticles: Part 2. ATR-FTIR and EXAFS study of the aqueous Zn(II)/oxalate/hematite ternary system.

    Science.gov (United States)

    Ha, Juyoung; Trainor, Thomas P; Farges, François; Brown, Gordon E

    2009-05-19

    Sorption of Zn(II) to hematite nanoparticles (HN) (av diam=10.5 nm) and microparticles (HM) (av diam=550 nm) was studied in the presence of oxalate anions (Ox2-(aq)) in aqueous solutions as a function of total Zn(II)(aq) to total Ox2-(aq) concentration ratio (R=[Zn(II)(aq)]tot/[Ox2-(aq)]tot) at pH 5.5. Zn(II) uptake is similar in extent for both the Zn(II)/Ox/HN and Zn(II)/Ox/HM ternary systems and the Zn(II)/HN binary system at [Zn(II)(aq)](tot)system than for the Zn(II)/Ox/HM ternary and the Zn(II)/HN and Zn(II)/HM binary systems at [Zn(II)(aq)]tot>4 mM. In contrast, Zn(II) uptake for the Zn(II)/HM binary system is a factor of 2 greater than that for the Zn(II)/Ox/HM and Zn(II)/Ox/HN ternary systems and the Zn(II)/HN binary system at [Zn(II)(aq)]totternary system at both R values examined (0.16 and 0.68), attenuated total reflectance Fourier transform infrared (ATR-FTIR) results are consistent with the presence of inner-sphere oxalate complexes and outer-sphere ZnOx(aq) complexes, and/or type A ternary complexes. In addition, extended X-ray absorption fine structure (EXAFS) spectroscopic results suggest that type A ternary surface complexes (i.e., >O2-Zn-Ox) are present. In the Zn(II)/Ox/HN ternary system at R=0.15, ATR-FTIR results indicate the presence of inner-sphere oxalate and outer-sphere ZnOx(aq) complexes; the EXAFS results provide no evidence for inner-sphere Zn(II) complexes or type A ternary complexes. In contrast, ATR-FTIR results for the Zn/Ox/HN sample with R = 0.68 are consistent with a ZnOx(s)-like surface precipitate and possibly type B ternary surface complexes (i.e., >O2-Ox-Zn). EXAFS results are also consistent with the presence of ZnOx(s)-like precipitates. We ascribe the observed increase of Zn(II)(aq) uptake in the Zn(II)/Ox/HN ternary system at [Zn(II)(aq)]tot>or=4 mM relative to the Zn(II)/Ox/HM ternary system to formation of a ZnOx(s)-like precipitate at the hematite nanoparticle/water interface.

  20. Study of the removal of mercury(II) and chromium(VI) from aqueous solutions by Moroccan stevensite

    International Nuclear Information System (INIS)

    Benhammou, A.; Yaacoubi, A.; Nibou, L.; Tanouti, B.

    2005-01-01

    The objective of the present study was to investigate the adsorption of the heavy metals mercury(II) and chromium(VI), from aqueous solutions, onto Moroccan stevensite. A mineralogical and physicochemical characterization of natural stevensite was carried out. In order to improve the adsorption capacity of stevensite for Cr(VI), a preparation of stevensite was carried out. It consists in saturating the stevensite by ferrous iron Fe(II) and reducing the total Fe by Na 2 S 2 O 4 . Then, the adsorption experiments were studied in batch reactors at 25 ± 3 deg. C. The influence of the pH solution on the Cr(VI) and Hg(II) adsorption was studied in the pH range of 1.5-7.0. The optimum pH for the Cr(VI) adsorption is in the pH range of 2.0-5.0 while that of Hg(II) is at the pH values above 4.0. The adsorption kinetics were tested by a pseudo-second-order model. The adsorption rate of Hg(II) is 54.35 mmol kg -1 min -1 and that of Cr(VI) is 7.21 mmol kg -1 min -1 . The adsorption equilibrium time for Hg(II) and Cr(VI) was reached within 2 and 12 h, respectively. The adsorption isotherms were described by the Dubinin-Radushkevich model. The maximal adsorption capacity for Cr(VI) increases from 13.7 (raw stevensite) to 48.86 mmol kg -1 (modified stevensite) while that of Hg(II) decreases from 205.8 to 166.9 mmol kg -1 . The mechanism of Hg(II) and Cr(VI) adsorption was discussed

  1. Experiment to study K+ → π+ + ''nothing'' at LAMPF II

    International Nuclear Information System (INIS)

    Marlow, D.R.

    1985-05-01

    An experiment to measure K + → π + + ''nothing'' (where ''nothing'' denotes unobservable neutral particles) at LAMPF II is described. This experiment is capable of measuring one K + → π + nu anti nu event for branching ratio of 10 -12 . 12 refs

  2. Validation of WIMS-AECL/(MULTICELL)/RFSP system by the results of phase-B test at Wolsung-II unit

    Energy Technology Data Exchange (ETDEWEB)

    Hong, In Seob; Min, Byung Joo; Suk, Ho Chun [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-03-01

    The object of this study is the validation of WIMS-AECL lattice code which has been proposed for the substitution of POWDERPUFS-V(PPV) code. For the validation of this code, WIMS-AECL/(MULTICELL)/RFSP (lattice calculation/(incremental cross section calculation)/core calculation) code system has been used for the Post-Simulation of Phase-B physics Test at Wolsung-II unit. This code system had been used for the Wolsong-I and Point Lepraeu reactors, but after a few modifications of WIMS-AECL input values for Wolsong-II, the results of WIMS-AECL/RFSP code calculations are much improved to those of the old ones. Most of the results show good estimation except moderator temperature coefficient test. And the verification of this result must be done, which is one of the further work. 6 figs., 15 tabs. (Author)

  3. A study on complex formation of cadmium(II) ions, 8

    International Nuclear Information System (INIS)

    Matsui, Haruo; Hirabayashi, Yoshihiro

    1984-01-01

    In the potentiometric titration of the solution containing a cadmium(II) ion and an amino acid, white precipitates often appear in the test solution, and they disturb the emf measurements. Such precipitates were formes in the solutions, pH ranging 7.5--8.5, during the course of titrations of the test solutions containing cadmium(II) ion and amino acid such as glycine, α-alanine. 2-aminobutanoic acid, 3-aminobutanoic acid, 4-aminobutanoic acid, 2-aminopentanoic acid, 5-aminopentanoic acid, 2-aminohexanoic acid, 6-aminohexanoic acid, aspartic acid, glutamic acid, asparagine, or glutamine. The identification of the precipitates obtained from the solutions containing cadmium(II) ion and L-aspartic acid, 4-aminobutanoic acid, or 6-aminohexanoic acid were carried out by both of elemental analysis and the infrared spectroscopy. These results indicated that the precipitate obtained from the solution containing cadmium(II) ion and L-aspartic acid was 1:1 cadmium(II)-L-aspartic acid complex and did not contain any cadmium(II) hydroxide, and other two precipitates were mostly cadmium(II) hydroxide and contained a little cadmium(II)-amino acid complexes. (author)

  4. Relative Leukocyte Telomere Length, Hematological Parameters and Anemia - Data from the Berlin Aging Study II (BASE-II).

    Science.gov (United States)

    Meyer, Antje; Salewsky, Bastian; Buchmann, Nikolaus; Steinhagen-Thiessen, Elisabeth; Demuth, Ilja

    2016-01-01

    The length of the chromosome ends, telomeres, is widely accepted as a biomarker of aging. However, the dynamic of the relationship between telomere length and hematopoietic parameters in the normal aging process, which is of particular interest with respect to age-related anemia, is not well understood. We have analyzed the relationship between relative leukocyte telomere length (rLTL) and several hematological parameters in the older group of the Berlin Aging Study II (BASE-II) participants. This paper also compares rLTL between both BASE-II age groups (22-37 and 60-83 years). Genomic DNA was extracted from peripheral blood leukocytes of BASE-II participants and used to determine rLTL by a quantitative PCR protocol. Standard methods were used to determine blood parameters, and the WHO criteria were used to identify anemic participants. Telomere length data were available for 444 younger participants (28.4 ± 3.1 years old; 52% women) and 1,460 older participants (68.2 ± 3.7 years old; 49.4% women). rLTL was significantly shorter in BASE-II participants of the older group (p = 3.7 × 10-12) and in women (p = 4.2 × 10-31). rLTL of older men exhibited a statistically significant, positive partial correlation with mean corpuscular hemoglobin (MCH; p = 0.012) and MCH concentration (p = 0.002). While these correlations were only observed in men, the rLTL of older women was negatively correlated with the number of thrombocytes (p = 0.015) in the same type of analysis. Among all older participants, 6% met the criteria to be categorized as 'anemic'; however, there was no association between anemia and rLTL. In the present study, we have detected isolated correlations between rLTL and hematological parameters; however, in all cases, rLTL explained only a small part of the variation of the analyzed parameters. In disagreement with some other studies showing similar data, we interpret the association between rLTL and some of the hematological parameters studied here to be

  5. Measurement of endotoxin. II. Comparison of reactivities measured by radioimmunoassay and with the limulus test

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, H [Okayama Univ. (Japan). School of Medicine

    1976-08-01

    Various endotoxins and the ether extracts of grampositive bacteria were measured immunologically by radioimmunoassay and also biologically by the Limulus test. The minimum amount of endotoxin detectable with the Limulus test was in the range from 1 ng/ml to 1 ..mu..g/ml, with the lysate of sensitivity, 100 ng ml (E. coli 0111: B4(B) lipopolysaccharide). On the other hand, by the radioimmunoassay they were estimated in the range of 0.3 to 10 times of dry weight. Endotoxin-like activity was detected in the ether extracts of grampositive bacteria at a minimum concentration between 1 ..mu..g/ml and 100 ..mu..g/ml with the Limulus test. However, most of them were estimated by the radioimmunoassay to be under 1/50 of dry weight. Various substances such as thrombin, thromboplastin, polynosinic-polycytidylic acid, polyadenylic-polyuridylic acid, carrageenan and human colonic mucosal antigen had cross reactivities of various degrees in the minimum concentration from 10 ..mu..g/ml to 10 mg/ml. Compounds such as thrombin and thromboplastin cross-reacting in the Limulus test were scarcely measured by the radioimmunoassay except for polynucleotides. From this study, it has become clear that the radioimmunoassay method is quite specific and accurate for quantitative measurements of endotoxin.

  6. Aging of snubbers in nuclear service: Phase I study results and Phase II plans

    International Nuclear Information System (INIS)

    Goodman, R.L.; Bush, S.H.; Page, R.E.

    1988-01-01

    Two major research areas were investigated in the Phase I snubber aging studies. The first area involved a preliminary evaluation of the effects of various aging mechanisms on snubber operation; failure modes of mechanisms were identified and their contributions to aging degradation were assessed relative to other failure modes. The second area involved estimating the efficacy of existing tests and examinations that are intended to determine the effects of aging and degradation. Available data on snubber behavior and operating experience were reviewed, using licensee event reports and other historical data for the 10-year period from 1973 through 1983. Value-impact was considered in terms of (1) exposure of workers to radioactive environments for examination/testing and (2) the cost for expansion of the snubber testing program due to failed snubbers. Results from the Phase I studies identified the need to modify or improve examination and testing procedures to enhance snubber reliability. Based on the results of the Phase I snubber studies, the seals and fluids were identified as the two principal elements affected by aging degradation in hydraulic snubbers. Phase II work, which was initiated in FY 1987, will develop cooperative activities between PNL and operating utilities through the Snubber Utility Group (SNUG), who will work to establish a strong data and experience base for both hydraulic and mechanical snubbers based on actual operating and maintenance history at nuclear power plants. Application guidelines for snubbers will be recommended based on the study results

  7. Glass polymorphism in glycerol–water mixtures: II. Experimental studies

    Science.gov (United States)

    Bachler, Johannes; Fuentes-Landete, Violeta; Jahn, David A.; Wong, Jessina; Giovambattista, Nicolas

    2016-01-01

    We report a detailed experimental study of (i) pressure-induced transformations in glycerol–water mixtures at T = 77 K and P = 0–1.8 GPa, and (ii) heating-induced transformations of glycerol–water mixtures recovered at 1 atm and T = 77 K. Our samples are prepared by cooling the solutions at ambient pressure at various cooling rates (100 K s–1–10 K h–1) and for the whole range of glycerol mole fractions, χ g. Depending on concentration and cooling rates, cooling leads to samples containing amorphous ice (χ g ≥ 0.20), ice (χ g ≤ 0.32), and/or “distorted ice” (0 HDA). PIA of ice domains within the glycerol–water mixtures is shown to be possible only up to χ g ≈ 0.32 (T = 77 K). This is rather surprising since it has been known that at χ g HDA upon compression. Upon heating samples recovered at 1 atm, we observe a rich phase behavior. Differential scanning calorimetry indicates that only at χ g ≤ 0.15, the water domains within the sample exhibit polyamorphism, i.e., the HDA-to-LDA (low-density amorphous ice) transformation. At 0.15 HDA domains. All samples (χ g ≤ 0.38) show: the crystallization of amorphous ice domains, followed by the glass transition of the vitrified glycerol–water domains and, finally, the melting of ice at high temperatures. Our work exemplifies the complex “phase” behavior of glassy binary mixtures due to phase-separation (ice formation) and polyamorphism, and the relevance of sample preparation, concentration as well as cooling rates. The presence of the distorted ice (called “interphase” by us) also explains the debated “drift anomaly” upon melting. These results are compatible with the high-pressure study by Suzuki and Mishima indicating disappearance of polyamorphism at P ≈ 0.03–0.05 GPa at χ g ≈ 0.12–0.15 [J. Chem. Phys., 2014, 141, 094505]. PMID:27044677

  8. Oxidation of Cu(II) aminopolycarboxylates by carbonate radical. A flash photolysis study

    International Nuclear Information System (INIS)

    Mandal, P.C.; Bardhan, D.K.

    1999-01-01

    Reactions of carbonate radical (CO 3 -. ) generated by photolysis or by radiolysis of a carbonate solution, with Cu(II) complexes of aminopolycarboxylic acids viz., Cu(II)ethylenediamine tetraacetate [Cu II EDTA] 2- and Cu(II)-iminodiacetate [Cu II IDA] were studied at pH 10.5 and ionic strength 0.2 mol x dm -3 . Time-resolved spectroscopy and kinetics for the transients were studied using flash photolysis and stable products arising from the ligand degradation of the complex were ascertained by steady-state radiolysis experiments. From the kinetic data it is observed that CO 3 -. radical reacts initially with Cu II -complex to form a transient intermediate having maximum absorption at 335 nm and 430 nm. From the subsequent reactions of this intermediate it was assigned to be Cu III .species. This Cu(III) species undergoes intermolecular electron transfer with the Cu II -complex to give a radical intermediate which again slowly reacts with Cu II -complex to give a long lived species containing Cu-C bond. This long lived species, however, slowly decomposed to give glyoxalic reaction between Cu III -complex and a suitable donor, the one electron reduction potential for [Cu III EDTA] 1- /[Cu II EDTA] 2- and [Cu III IDA] +1 /Cu II IDA was determined. (author)

  9. The Test for Flow Characteristics of Tubular Fuel Assembly(II) - Experimental results and CFD analysis

    International Nuclear Information System (INIS)

    Park, Jong Hark; Chae, H. T.; Park, C.; Kim, H.

    2006-12-01

    A test facility had been established for the experiment of velocity distribution and pressure drop in a tubular fuel. A basic test had been conducted to examine the performance of the test loop and to verify the accuracy of measurement by pitot-tube. In this report, test results and CFD analysis for the hydraulic characteristics of a tubular fuel, following the previous tests, are described. Coolant velocities in all channels were measured using pitot-tube and the effect of flow rate change on the velocity distribution was also examined. The pressure drop through the tubular fuel was measured for various flow rates in range of 1 kg/s to 21 kg/s to obtain a correlation of pressure drop with variation of flow rate. In addition, a CFD(Computational Fluid Dynamics) analysis was also done to find out the hydraulic characteristics of tubular fuel such as velocity distribution and pressure drop. As the results of CFD analysis can give us a detail insight on coolant flow in the tubular fuel, the CFD method is a very useful tool to understand the flow structure and phenomena induced by fluid flow. The CFX-10, a commercial CFD code, was used in this study. The two results by the experiment and the CFD analysis were investigated and compared with each other. Overall trend of velocity distribution by CFD analysis was somewhat different from that of experiment, but it would be reasonable considering measurement uncertainties. The CFD prediction for pressure drop of a tubular fuel shows a tolerably good agreement with experiment within 8% difference

  10. Evaluation report on SCTF Core-II test S2-19

    International Nuclear Information System (INIS)

    Ohnuki, Akira; Iwamura, Takamichi; Iguchi, Tadashi; Abe, Yutaka; Murao, Yoshio; Adachi, Hiromichi.

    1991-03-01

    Experimental studies using Slab Core Test Facility (SCTF) have revealed that the heat transfer enhancement in higher power bundles is mainly governed by the radial power ratio in core during the reflood in PWR-LOCA. As a physical mechanism for the heat transfer enhancement, it can be considered from the experimental evidence that the increase of upward steam flow rate in a higher power bundle which is caused by the higher steam production rate in the bundle gives the higher upward liquid flow rate in the bundle and the increase of the liquid flow rate gives the heat transfer enhancement. In order to develop a mechanistic model for the heat transfer enhancement based on this idea, the following relations should be identified quantitatively: (1) Relation between the steam production rate and the upward liquid flow rate, (2) Cross flow rate above the quench front and (3) Relation between the degree of heat transfer enhancement due to radial power ratio and the amount of increase of upward liquid flow rate. In this report, the above relation (3) was investigated experimentally as a step to develop the mechanistic model using the SCTF where the relation between the radial power ratio and the heat transfer enhancement has been made clear quantitatively. The degree of increase of heat transfer between two forced feed tests with the different flow rate in LPCI period was compared with the degree of heat transfer enhancement under a radial power ratio in the previous SCTF tests. The two forced feed tests were performed under the condition without any significant two-dimensional hydraulic behavior in core. The ratio of the mass flow rate between the two tests was about double. (author)

  11. Thermal-hydraulic design calculations for the annular fuel element with replaceable test bundles (TOAST) on the test zone position 205 of KNK II/3

    International Nuclear Information System (INIS)

    Norajitra, P.

    1984-10-01

    Annular fuel elements are foreseen in KNK II as carrier elements for irradiation inserts and test bundles. For the third core a reloadable annular element on position 205 is foreseen, in which replaceable 19-pin test bundles (TOAST) shall be irradiated. The present report deals with the thermal-hydraulic design of the annular carrier element and the test bundle, whereby the test bundle required additional optimization. The code CIA has been used for the calculations. Start of irradiation of the subassembly is planned at the beginning of the third core operation. After optimization of the pin-spacer geometry in the test bundle, design calculations for both bundles were performed, whereby thermal coupling between both was taken into account. The calculated mass-flows and temperature distributions are given for the nominal and the eccentric element configuration. The calculated bundle pressure losses have been corrected according to experimental results [de

  12. CMHC research project: Testing of air barrier construction details, II: Report

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-01

    Air leakage control through the building envelope of wood framed houses is more important than ever. The leakage of air is controlled by the air barrier system. There are several new technologies to construct an air barrier system for the building envelope. These are the Poly Approach, the Air Drywall Approach and the EASE system. The development of these systems was undertaken primarily by the building community without significant research and development. The purpose of this study was to determine the actual performance of several different types of construction details for each of the different approaches. Each of these details was designed and constructed using one of the air barrier methods and tested in the laboratory. The test details included the sill plate, the partition wall, the stair stringer, the electrical outlets, the bathtub detail, the plumbing stack detail, the metal chimney detail, the bathroom fan detail and the EASE wall system.

  13. Desempenho de crianças pré-termo com muito baixo peso e extremo baixo peso segundo o teste Denver-II The performance of pre-term children with very and extreme low weight according to the Denver-II test

    Directory of Open Access Journals (Sweden)

    Lívia de Castro Magalhães

    2011-12-01

    Full Text Available OBJETIVOS: analisar o desempenho de crianças da região metropolitana Belo Horizonte/MG nascidas pré-termo com muito e extremo baixo peso nos itens do teste Denver II. MÉTODOS: as crianças foram selecionadas em um programa de acompanhamento do desenvolvimento de crianças de risco. A amostra incluiu 177 crianças, nas quais o Teste de Denver II foi aplicado nas idades corrigidas de 4, 8, 12, 18 e 24 meses. As respostas foram comparadas (χ2 aos dados da amostra normativa do instrumento. RESULTADOS: crianças pré-termo de muito e extremo baixo peso apresentaram desempenho superior no primeiro ano de vida com desvantagem a partir dos 12 meses em relação à amostra normativa do Denver II. O grupo de extremo baixo peso foi o que apresentou pior desempenho. CONCLUSÕES: houve diferenças no padrão de respostas das crianças examinadas em relação à amostra normativa do Denver II, sendo importante fazer mais estudos acerca da validade do teste para a população brasileira.OBJECTIVES: to evaluate the performance on the Denver II test of preterm children with very and extreme low weight from the Belo Horizonte/MG metropolitan region. METHODS: the children were selected as part of a program to monitor the development of children at risk. The sample included 177 children, to whom the Denver II Test was applied at corrected ages of 4, 8, 12, 18 and 24 months. The responses were compared (χ2 to data from a normative sample. RESULTS: preterm children with very or extremely low weight showed improved performance in the first year of life, although disadvantages began to emerge after twelve months in relation to the normative Denver II sample. The extremely low weight group performed the worst. CONCLUSIONS: there were differences in the pattern of children's responses compared to those of the normative Denver II sample, and it is important to carry out further studies of the validity of this test for the Brazilian population.

  14. Tower Shielding Reactor II design and operation report. Vol. 3. Assembling and testing of the control mechanism assembly

    International Nuclear Information System (INIS)

    Ward, D.R.; Holland, L.B.

    1979-09-01

    The mechanisms that are operated to control the reactivity of the Tower Shielding Reactor II(TSR-II) are mounted on a Control Mechanism Housing (CMH) that is centered inside the reactor core. The information required to procure, fabricate, inspect, and assemble a CMH is contained in the ORNL engineering drawings listed in the appropriate sections. The components are fabricated and inspected from these drawings in accordance with a Quality Assurance Plan and a Manufacturing Plan. The material in this report describes the acceptance and performance tests of CMH subassemblies used ty the Tower Shielding Facility (TSF) staff but it can also be used by personnel fabricating the components. This information which was developed and used before the advent of the formalized QA Program and Manufacturing Plans evolved during the fabrication and testing of the first five CMHs

  15. Kinetic and equilibrium study for the sorption of Pb(II) ions from ...

    African Journals Online (AJOL)

    Kinetic and equilibrium study for the sorption of Pb(II) ions from aqueous phase by water hyacinth ( Eichhornia crassipes ) ... Bulletin of the Chemical Society of Ethiopia ... Abstract. This paper reports the kinetic and equilibrium studies of Eichhornia crassipes root biomass as a biosorbent for Pb(II) ions from aqueous system.

  16. A systematic review of the factors associated with interest in predictive genetic testing for obesity, type II diabetes and heart disease.

    Science.gov (United States)

    Collins, J; Ryan, L; Truby, H

    2014-10-01

    In the future, it may be possible for individuals to take a genetic test to determine their genetic predisposition towards developing lifestyle-related chronic diseases. A systematic review of the literature was undertaken to identify the factors associated with an interest in having predictive genetic testing for obesity, type II diabetes and heart disease amongst unaffected adults. Ovid Medline, PsycINFO and EMBASE online databases were searched using predefined search terms. Publications meeting the inclusion criteria (English language, free-living adult population not selected as a result of their disease diagnosis, reporting interest as an outcome, not related to a single gene inherited disease) were assessed for quality and content. Narrative synthesis of the results was undertaken. From the 2329 publications retrieved, eight studies met the inclusion criteria and were included in the review. Overall, the evidence base was small but of positive quality. Interest was associated with personal attitudes towards disease risk and the provision of information about genetic testing, shaped by perceived risk of disease and expected outcomes of testing. The role of demographic factors was investigated with largely inconclusive findings. Interest in predictive genetic testing for obesity, type II diabetes or heart disease was greatest amongst those who perceived the risk of disease to be high and/or the outcomes of testing to be beneficial. © 2013 The British Dietetic Association Ltd.

  17. Synthesis, characterization, spectroscopic and theoretical studies of new zinc(II), copper(II) and nickel(II) complexes based on imine ligand containing 2-aminothiophenol moiety

    Science.gov (United States)

    Shafaatian, Bita; Mousavi, S. Sedighe; Afshari, Sadegh

    2016-11-01

    New dimer complexes of zinc(II), copper(II) and nickel(II) were synthesized using the Schiff base ligand which was formed by the condensation of 2-aminothiophenol and 2-hydroxy-5-methyl benzaldehyde. This tridentate Schiff base ligand was coordinated to the metal ions through the NSO donor atoms. In order to prevent the oxidation of the thiole group during the formation of Schiff base and its complexes, all of the reactions were carried out under an inert atmosphere of argon. The X-ray structure of the Schiff base ligand showed that in the crystalline form the SH groups were oxidized to produce a disulfide Schiff base as a new double Schiff base ligand. The molar conductivity values of the complexes in dichloromethane implied the presence of non-electrolyte species. The fluorescence properties of the Schiff base ligand and its complexes were also studied in dichloromethane. The products were characterized by FT-IR, 1H NMR, UV/Vis spectroscopies, elemental analysis, and conductometry. The crystal structure of the double Schiff base was determined by single crystal X-ray diffraction. Furthermore, the density functional theory (DFT) calculations were performed at the B3LYP/6-31G(d,p) level of theory for the determination of the optimized structures of Schiff base complexes.

  18. A Teaching Method on Basic Chemistry for Freshman (II) : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2004-01-01

    This report deals with review of a teaching method on basic chemistry for freshman in this first semester. We tried to review this teaching method with pre-test and post-test by means of the official and private questionnaires. Several hints and thoughts on teaching skills are obtained from this analysis.

  19. Behavior of EBR-II Mk-V-type fuel elements in simulated loss-of-flow tests

    International Nuclear Information System (INIS)

    Liu, Y.Y.; Tsai, H.; Billone, M.C.; Kramer, J.M.

    1992-01-01

    The next step in the development of metal fuels for the integral fast reactor (IFR) is the conversion of the Experimental Breeder Reactor II (EBR-II) core to one containing the ternary U-20 Pu-10 Zr alloy clad with HT-9 cladding, i.e., the Mk-V core. This paper presents results of three hot-cell furnace simulation tests on irradiated Mk-V-type fuel elements (U-19 Pu-10 Zr/HT-9), which were performed to support the safety case for the Mk-V core. These tests were designed to envelop an umbrella (bounding) unlikely loss-of-flow (LOF) event in EBR-II during which the calculated peak cladding temperature would reach 776 degree C for < 2 min. The principal objectives of these tests were (a) demonstration of the safety margin of the fuel element, (b) investigation of cladding breaching behavior, and (c) provision of data for validation of the FPIN2 and LIFE-METAL codes

  20. Full-scale vibration tests of Atucha II N.P.P. Part I: objectives, instrumentation and test description

    International Nuclear Information System (INIS)

    Konno, T.; Tsugawa, T.; Sala, G.; Friebe, T.M.; Prato, C.A.; Godoy, A.R.

    1995-01-01

    The main purpose of the tests was to provide experimental data on the dynamic characteristics of the main reactor building and adjacent structures of a full-scale nuclear power plant built on deep Quaternary soil deposits. Test results were intended to provide a benchmark case for control and calibration of state-of-the-art numerical techniques used for engineering design of new plants and assessment of existing facilities. Interpretation of test results and calibration of numerical analyses are described in other associated papers. (author). 5 figs

  1. Nondestructive testing of welds in steam generators for advanced gas cooled reactors at Heyshamm II and Torness

    International Nuclear Information System (INIS)

    Parkin, K.; Bainbridge, A.; Carver, K.; Hammell, R.; Lack, B.J.

    1985-01-01

    The paper concerns non-destructive testing (NDT) of welds in advanced gas cooled steam generators for Heysham II and Torness nuclear power stations. A description is given of the steam generator. The selection of NDT techniques is also outlined, including the factors considered to ascertain the viability of a technique. Examples are given of applied NDT methods which match particular fabrication processes; these include: microfocus radiography, ultrasonic testing of austenitic tube butt welds, gamma-ray isotope projection system, surface crack detection, and automated radiography. Finally, future trends in this field of NDT are highlighted. (UK)

  2. Design Report for a 19-pin carbide test-bundle in a ring-subassembly of the test zone of KNK II/2

    International Nuclear Information System (INIS)

    Haefner, H.E.

    1982-03-01

    This report describes a 19-rod carbide test bundle in an annular oxide ring element placed at the position 201 of the test zone in the second core of KNK II as well as its behavior during the period of operation. The selected fuel rod concept includes low pellet density and a relatively large gap width as well as helium bonding between fuel and cladding. Characteristic design and operation data are: rod diameter 8.5 mm, pellet diameter 7.0 mm, maximum nominal linear rating 800 W/cm, maximum nominal burnup 70 MWd/kgHM. This report exclusively deals with the carbide test bundle and its individual components; it describes methods, criteria and results concerning the design. The annular carrier element with its head and foot is treated in a separate report. The loadability of the test bundle and its individual components is demonstrated by generally valid standards for strength criteria [de

  3. The Pediatric Obsessive-Compulsive Disorder Treatment Study II: rationale, design and methods

    Directory of Open Access Journals (Sweden)

    March John S

    2009-01-01

    Full Text Available Abstract This paper presents the rationale, design, and methods of the Pediatric Obsessive-Compulsive Disorder Treatment Study II (POTS II, which investigates two different cognitive-behavior therapy (CBT augmentation approaches in children and adolescents who have experienced a partial response to pharmacotherapy with a serotonin reuptake inhibitor for OCD. The two CBT approaches test a "single doctor" versus "dual doctor" model of service delivery. A specific goal was to develop and test an easily disseminated protocol whereby child psychiatrists would provide instructions in core CBT procedures recommended for pediatric OCD (e.g., hierarchy development, in vivo exposure homework during routine medical management of OCD (I-CBT. The conventional "dual doctor" CBT protocol consists of 14 visits over 12 weeks involving: (1 psychoeducation, (2, cognitive training, (3 mapping OCD, and (4 exposure with response prevention (EX/RP. I-CBT is a 7-session version of CBT that does not include imaginal exposure or therapist-assisted EX/RP. In this study, we compared 12 weeks of medication management (MM provided by a study psychiatrist (MM only with two types of CBT augmentation: (1 the dual doctor model (MM+CBT; and (2 the single doctor model (MM+I-CBT. The design balanced elements of an efficacy study (e.g., random assignment, independent ratings with effectiveness research aims (e.g., differences in specific SRI medications, dosages, treatment providers. The study is wrapping up recruitment of 140 youth ages 7–17 with a primary diagnosis of OCD. Independent evaluators (IEs rated participants at weeks 0,4,8, and 12 during acute treatment and at 3,6, and 12 month follow-up visits. Trial registration NCT00074815

  4. Charged NUT field : [Part] I. Motion of test particles and [Part] II. Cosmic censorship

    International Nuclear Information System (INIS)

    Krori, K.D.

    1981-01-01

    Some properties of the charged NUT field are studied. In the first part of the paper, some general aspects of the charged NUT field have been investigated using uncharged and charged particles. The behaviour of the particles near the singularity has also been considered. In the second part of the paper, the charged NUT sources in the context of cosmic censorship hypothesis are studied. Motion of charged particles in the equatorial plane and along the axis is considered. From this investigation the interesting result is discovered that by such a bombardment of charged test particles, the existing event horizons cannot be destroyed but, in contrast to the Reissner-Nordstrom field, naked singularities do not get enveloped by event horizons. (author)

  5. Spectroscopic and DFT studies of flurbiprofen as dimer and its Cu(II) and Hg(II) complexes

    Science.gov (United States)

    Sagdinc, Seda; Pir, Hacer

    2009-07-01

    The vibrational study in the solid state of flurbiprofen and its Cu(II) and Hg(II) complexes was performed by IR and Raman spectroscopy. The changes observed between the IR and Raman spectra of the ligand and of the complexes allowed us to establish the coordination mode of the metal in both complexes. The comparative vibrational analysis of the free ligand and its complexes gave evidence that flurbiprofen binds metal (II) through the carboxylate oxygen. The fully optimized equilibrium structure of flurbiprofen and its metal complexes was obtained by density functional B3LYP method by using LanL2DZ and 6-31 G(d,p) basis sets. The harmonic vibrational frequencies, infrared intensities and Raman scattering activities of flurbiprofen were calculated by density functional B3LYP methods by using 6-31G(d,p) basis set. The scaled theoretical wavenumbers showed very good agreement with the experimental values. The electronic properties of the free molecule and its complexes were also performed at B3LYP/6-31G(d,p) level of theory. Detailed interpretations of the infrared and Raman spectra of flurbiprofen are reported. The UV-vis spectra of flurbiprofen and its metal complexes were also investigated in organic solvents.

  6. Spectroscopic study of cadmium (II) complexes with heterocyclic dithiocarbamate ligands

    International Nuclear Information System (INIS)

    Garcia-Fontan, S.; Rodriguez-Seoane, P.; Casas, J.S.; Sordo, J.; Jones, M.M.

    1993-01-01

    Cadmium(II) dithiocarbamates [Cd(dtc) 2 ] (dtc=4-carboxamidopiperidine-1-carbodithioate, morpholine-1-carbodithioate or 4-(2-hydroxyethyl)piperazine-1-carbodithioate) and [Cd(dtc) 2 ].H 2 O (dtc=4-hydroxypiperidine-1-carbodithioate} have been prepared and characterized by thermal analysis and IR and NMR ( 13 C, 113 Cd) spectrometry. Two of these ligands have previously been shown capable of removing cadmium from its aged in vivo storage sites. The use of solid state 13 C NMR measurements to establish the coordination mode of the dithiocarbomate ligands is also examined and the difficulties which arise are discussed. (orig.)

  7. Parameter sensitivity study of a Field II multilayer transducer model on a convex transducer

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2009-01-01

    A multilayer transducer model for predicting a transducer impulse response has in earlier works been developed and combined with the Field II software. This development was tested on current, voltage, and intensity measurements on piezoceramics discs (Bæk et al. IUS 2008) and a convex 128 element...... ultrasound imaging transducer (Bæk et al. ICU 2009). The model benefits from its 1D simplicity and hasshown to give an amplitude error around 1.7‐2 dB. However, any prediction of amplitude, phase, and attenuation of pulses relies on the accuracy of manufacturer supplied material characteristics, which may...... is a quantitative calibrated model for a complete ultrasound system. This includes a sensitivity study aspresented here.Statement of Contribution/MethodsThe study alters 35 different model parameters which describe a 128 element convex transducer from BK Medical Aps. The changes are within ±20 % of the values...

  8. Computerized Adaptive Testing. A Case Study.

    Science.gov (United States)

    1980-12-01

    Vocational Interest Blank in 1927 [Dubois 1970]. 3. German Contributions Cattell also studied for a period of three years in Leipzig under Wilhelm Wundt in the...world’s first psychological laboratory, 2 founded by Wundt in 1879 [Heidbreder 1933]. 2William James’ laboratory, established at Harvard in 1875, did...have become important parts of psychological test theory. Under Wundt , Spearman’s principal endeavor was experimental psychology, but he also found time

  9. Cold Test Results of the ISAC-II Medium Beta High Gradient Cryomodule

    CERN Document Server

    Laxdal, R E; Clark, G S; Fong, K; Mitra, A K; Poirier, R L; Rawnsley, B; Ries, T; Sekatchev, I; Stanford, G; Zvyagintsev, V

    2004-01-01

    Many proposals (RIA, Eurisol, ISAC-II) are emerging for a new generation of high gradient heavy ion accelerators. The ISAC-II medium beta cryomodule represents the first realized application that encorporates many new techniques to improve the performance over machines presently being used for beam delivery. The machine lattice, compatible with multi-charge acceleration, uses high field (9T) superconducting solenoids with bucking coils for active fringe field compensation. The bulk niobium quarter wave medium beta cavity produces 6 MV/m over an effective length of 18cm with a peak surface field of ~30 MV/m. TRIUMF has developed a mechanical tuner capable of both coarse (kHz) and fine (Hz) frequency adjustments of the cavity. The demonstrated tuner resolution is better than 0.1 μm (0.6 Hz). A new rf coupling loop has been developed that operates at 200 Watts forward power with less than 0.5 Watt of power being added to the helium load. Cold alignment in ISAC-II has been done with rf pick-ups using a ...

  10. Infrared and Raman spectroscopic study of ion pairing of strontium(II ...

    African Journals Online (AJOL)

    ABSTRACT. Infrared and Raman spectroscopy techniques have been used to study the ionic interactions of strontium(II) and barium(II) with thiocyanate ion in liquid ammonia. A number of bands were observed in both ν(CN) and ν(CS) regions of infrared and Raman spectra and these were assigned to 1:1 contact ion pair, ...

  11. Behavior of EBR-II Mk-V-type fuel elements in simulated loss-of-flow tests

    International Nuclear Information System (INIS)

    Liu, Y.Y.; Tsai, H.; Billone, M.C.; Holland, J.W.; Kramer, J.M.

    1992-11-01

    This report discusses three furnace heating tests which were conducted with irradiated, HT9-clad and U-19wt.%Pu-l0wt.%Zr-alloy fuel, Mk-V-type fuel elements in the Alpha-Gamma Hot Cell Facility at Argonne National Laboratory, Illinois. In general, very significant safety margins for fuel-element cladding breaching have been demonstrated in these tests, under conditions that would envelop a bounding unlikely loss-of-flow event in EBR-II. Highlights of the test results will be given, as well as discussions of the cladding breaching mechanisms, axial fuel motion, and fuel surface liquefaction found in high-temperature testing of irradiated metallic fuel elements

  12. Evaluation of water repellent treatments applied to stones used in andalusian cathedrals. II. Salt crystallization test

    Directory of Open Access Journals (Sweden)

    Villegas Sánchez, R.

    1993-06-01

    Full Text Available In a previous paper we have studied the changes that have ocurred in the properties related to water access and movement in the stone after the application of water repellent treatments. In this work we compare the weathering resistance of treated and untreated samples by means of sodium sulphate crystallization test. After finishing the test (75 cycles properties related to water have been measured again to know if the treatments have undergone any kind of deterioration and lose their water repellent characteristics.

    En un artículo anterior se han evaluado los cambios producidos en las propiedades relacionadas con el acceso y movimiento de agua en la piedra como consecuencia de la aplicación de tratamientos de hidrofugación. En este trabajo se compara la resistencia a la alteración producida por sales de las probetas tratadas y sin tratar, sometiéndolas al ensayo de cristalización de sulfato sódico. Tras finalizar el ensayo (75 ciclos se han medido nuevamente las propiedades relacionadas con el agua, con objeto de comprobar si los tratamientos han sufrido alguna alteración y si mantienen sus características hidrófugas.

  13. Comparative studies on P-vanillin and O-vanillin of 2-hydrazinyl-2-oxo-N-phenylacetamide and their Mn(II) and Co(II) complexes

    Science.gov (United States)

    Yousef, T. A.; El-Reash, G. M. Abu; El-Tabai, M. N.

    2018-05-01

    Synthesis of complexes derived from hydrazones derived from both P-vanillin (H2L1) and its isomer O-vanillin (H2L2) of 2-hydrazinyl-2-oxo-N-phenylacetamide that coordinated with high magnetic metal ions of both Mn(II) and Co(II) were performed and characterized by different physicochemical methods, elemental analysis, (1H NMR, IR, and UV-visible spectra), also thermal analysis (TG and DTG) techniques and magnetic measurements. The molecular structures of the ligands and their Mn(II) and Co(II) complexes were optimized theoretically and the quantum chemical parameters were calculated. IR spectra suggest that the H2L1 behaved in a mononegative bidentate manner with both but H2L2 coordinated as mononegative tridentate with both Mn(II) and Co(II). The electronic spectra of the complexes as well as their magnetic moments suggested octahedral geometries for all the isolated complexes. The calculated values of binding energies indicated the stability of complexes is higher than that of ligand. The kinetic and thermodynamic parameters for the different decomposition steps in complexes were calculated using Coats-Redfern and Horowitz-Metzger equations. Moreover, the prepared ligands and their Mn(II) and Co(II) complexes were individually tested against a panel of gram positive Bacillus Subtilis and negative Escherichia coli microscopic organisms. Additionally cytotoxicity assay of two human tumor cell lines namely; hepatocellular carcinoma (liver) HePG-2, and mammary gland (breast) MCF-7 were tested.

  14. TEST and EVALUATION REPORT FOR THE HEDGEHOG-II PACKAGING SYSTEMS DOT-7A TYPE A CONTAINER

    International Nuclear Information System (INIS)

    KELLY, D.L.

    2003-01-01

    This report documents the US. Department of Transportation Specification 7A (DOT-7A) Type A compliance test and evaluation results for the Hedgehog-II packaging systems. The approved Hedgehog-II packaging configurations provide primary and secondary containment. The approved packaging configurations described within this report are designed to ship Type A quantities of radioactive materials, normal form. Contents may be in solid or liquid form. Liquids transported in the approved 1 L glass bottle assembly shall have a specific gravity of less than or equal to 1.6. Liquids transported in all other approved configurations shall have a specific gravity of less than or equal to 2.0. The solid contents, including packaging, are limited in weight to the gross weight of the as-tested liquids and bottles. The approved Hedgehog-II packaging configurations described in this report may be transported by air, and have been evaluated as meeting the applicable International Air Transport Association/International Civil Aviation Organization (IATA/ICAO) Dangerous Goods Regulations in addition to the DOT requirements

  15. Two-dimensional thermal-hydraulic behavior in core in SCTF Core-II forced feed reflood tests

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Okubo, Tsutomu; Ohnuki, Akira; Abe, Yutaka; Adachi, Hiromichi

    1987-01-01

    Major purpose of the Slab Core Test Program is to investigate the two-dimensional thermal-hydraulic behavior in the core during the reflood phase of a PWR-LOCA. It was revealed in the previous Slab Core Test Facility (SCTF) Core-II test results that the heat transfer was enhanced in the higher power bundles and degraded in the lower power bundles in the non-uniform radial power profile tests. In order to separately evaluate the effect of the radial power (Q) distribution itself and the effect of the radial temperature (T) distribution, four tests were performed with steep Q and T, flat Q and T, steep Q and flat T, and flat Q and steep T. Based on the test results, it was concluded that the radial temperature distribution which accompanied the radial power distribution was the dominant factor of the two-dimensional thermal-hydraulic behavior in the core during the initial period. Selected data from these four tests are also presented in this report. Some data from Test S2-12 (steep Q, T) were compared with TRAC post-test calculations performed by the Los Alamos National Laboratory. (author)

  16. Degradation of PVC/HC blends. II. Terrestrial plant growth test.

    Science.gov (United States)

    Pascu, Mihaela; Agafiţei, Gabriela-Elena; Profire, Lenuţa; Vasile, Cornelia

    2009-01-01

    The behavior at degradation by soil burial of some plasticized polyvinyl chloride (PVC) based blends with a variable content of hydrolyzed collagen (HC) has been followed. The modifications induced in the environment by the polymer systems (pH variation, physiologic state of the plants, assimilatory pigments) were studied. Using the growth test of the terrestrial plants, we followed the development of Triticum (wheat), Helianthus annus minimus (little sunflower), Pisum sativum (pea), and Vicia X hybrida hort, during a vegetation cycle. After the harvest, for each plant, the quantities of chlorophyll and carotenoidic pigments and of trace- and macroelements were determined. It was proved that, in the presence of polymer blends, the plants do not suffer morphological and physiological modifications, the products released in the culture soil being not toxic for the plants growth.

  17. Hyoid bone position and head posture comparison in skeletal Class I and Class II subjects: A retrospective cephalometric study

    Directory of Open Access Journals (Sweden)

    Pawankumar Dnyandeo Tekale

    2014-01-01

    Full Text Available Objective: The aim of the study was to investigate the hyoid bone position and the head posture using lateral cephalograms in subjects with skeletal Class I and skeletal Class II pattern and to investigate the gender differences. Materials and Methods: The study used lateral cephalograms of 40 subjects (20 skeletal Class I pattern; 20 skeletal Class II pattern. Lateral cephalograms were traced and analyzed for evaluation of the hyoid bone position and the head posture using 34 parameters. Independent sample t-test was performed to compare the differences between the two groups and between genders in each group. Statistical tests were performed using NCSS 2007 software (NCSST, Kaysville, Utah, USA. Results: The linear measurements between the hyoid bone (H and cervical spine (CV2ia, the nasion-sella line, palatal line nasion line, the anterior nasal spine (ANS to perpendicular projection of H on the NLP (NLP- Nasal Linear Projection (H-NLP/ANS as well as the posterior cranial points (Bo, Ar and S points were found to be less in skeletal Class II subjects. The measurement H-CV2ia was found to be less in males with skeletal Class I pattern and H-CV4ia was found to be less in males with skeletal Class II pattern. The natural head posture showed no significant gender differences. Conclusion: The position of hyoid bone was closer to the cervical vertebra horizontally in skeletal Class II subjects when compared with skeletal Class I subjects. In males, the hyoid bone position was closer to the cervical vertebra horizontally both in skeletal Class I and skeletal Class II subjects.

  18. Test-retest studies in quantitative sensory testing

    DEFF Research Database (Denmark)

    Werner, M U; Petersen, M A; Bischoff, J M

    2013-01-01

    Quantitative sensory testing (QST) investigates the graded psychophysical response to controlled thermal, mechanical, electrical or chemical stimuli, allowing quantification of clinically relevant perception and pain thresholds. The methods are ubiquitously used in experimental and clinical pain...... research, and therefore, the need for uniform assessment procedures has been emphasised. However, varying consistency and transparency in the statistical methodology seem to occur in the QST literature. Sixteen publications, evaluating aspects of QST variability, from 2010 to 2012, were critically reviewed...

  19. Preparation of phenacylchloride, morpholinophenacyl and N-Piperidinophenacyl oximes and study of their complexation with Copper (II) and Cobalt (II) ions

    International Nuclear Information System (INIS)

    Ali, Kamal Eldin Ahmed

    1999-01-01

    The aim of the present work is to prepare phenacyl chloride oxime and phenacyl of N-Piperidine and morpholine derivatives, and mainly to study their complexes with Cu(II) and Co(II) ions with objective ascertaining that one of these ligands can be used in quantitative extraction of these metal ions from the aqueous solution. Copper (II) salts form 1:1 complexes with the phenyacyl oximes of N-piperidine and morpholine and 1:2 complex with phenacyl chloride oxime. However, cobalt(II) salts form 1:2 complexes with phenacyl oxime of N-piperidine and morpholine but does not complex with phenacyl chloride oxime. The stoichiometry of these complexes were determined by UV/VIS spectrophotometry using the mole ratio, continuous variation and slope ratio methods.The stability constants of the five complexes were calculated from aberrances using Job's method. They showed that the copper (II) and cobalt (II) complexes with N-piperidinophenacy oxime are more stable than those with morpholinophenacyl oxime. Copper (II) complexes with any of these two ligands are more stable than those of cobalt (II). IR spectra of the complexes of copper (II) and cobalt (II) with phenacyl oxime of N-piperidine and morpholine show diminished peaks of hydrogen bonds between N and O atoms of the ligand. Specific extractabilities using amylalcohol of copper (II) complexes with the three ligands increase from PH4 to reach its maximum at PH8. The high value for N-piperidinophenacyl oxime ligand (96%-97%) indicates that, this ligand can be used as analytical reagent for the quantitative spectrophotometric determination of copper (II) salts in aqueous media. Cobalt (II) complexes were formed and extracted from solution only at PH6 (specific PH). The extractabilities ranging from 81.6-87.2% warrants the use of these ligands in quantitative spectrophotometric determination of cobalt (II).(Author)

  20. Dynamic adsorption studies for the removal of Cd (II) and Ni (II) from ...

    African Journals Online (AJOL)

    The adsorption was found to be more effective at higher concentrations of metals and with smaller adsorbent particle size. ... Recommendation was made such that, mahogany leaves should be studied for the remediation of other heavy metals, such as lead, chromium, mercury, zinc and uranium among others. Keywords: ...

  1. STUDIES OF Ni(II) & Cu(II) COMPLEXES WITH AMPICILLIN

    African Journals Online (AJOL)

    akg

    ABSTRACT. The Kolo Creek E2.0 reservoir oils from the Nigerian Niger Delta region have been studied for molecular marker by characterisation using full scan GC-MS and GC-MS-MS transition from 412 → 369. An existing molecular marker compound normally found in coals and lignites has been observed in some these ...

  2. Ultrasonographic Evaluation of Zone II Partial Flexor Tendon Lacerations of the Fingers: A Cadaveric Study.

    Science.gov (United States)

    Kazmers, Nikolas H; Gordon, Joshua A; Buterbaugh, Kristen L; Bozentka, David J; Steinberg, David R; Khoury, Viviane

    2018-04-01

    Accurate assessment of zone II partial flexor tendon lacerations in the finger is clinically important. Surgical repair is recommended for lacerations of greater than 50% to 60%. Our goal was to evaluate ultrasonographic test characteristics and accuracy in identifying partial flexor tendon lacerations in a cadaveric model. From fresh-frozen above-elbow human cadaveric specimens, 32 flexor digitorum profundus tendons were randomly selected to remain intact or receive low- or high-grade lacerations involving 10% to 40% and 60% to 90% of the radioulnar width within Verdan Zone II, respectively. Static and dynamic ultrasonography using a linear array 14-MHz transducer was performed by a blinded musculoskeletal radiologist. Sensitivities, specificities, and other standard test performance metrics were calculated. Actual and measured percentages of tendon laceration were compared by the paired t test. After randomization, 24 tendons were lacerated (12 low- and 12 high-grade), whereas 8 remained intact. The sensitivity and specificity in detecting the presence versus absence of a partial laceration were 0.54 and 0.75, respectively, with positive and negative likelihood ratio values of 2.17 and 0.61. For low-grade lacerations, the sensitivity and specificity were 0.25 and 0.85, compared to 0.83 and 0.85 for high-grade lacerations. Ultrasonography underestimated the percentage of tendon involvement by a mean of 18.1% for the study population as a whole (95% confidence interval, 9.0% to 27.2%; P partial flexor digitorum profundus lacerations in a cadaveric model. © 2017 by the American Institute of Ultrasound in Medicine.

  3. The generation, validation and testing of a coupled 219-group neutron 36-group gamma ray AMPX-II library

    International Nuclear Information System (INIS)

    Panini, G.C.; Siciliano, F.; Lioi, A.

    1987-01-01

    The main characteristics of a P 3 coupled 219-group neutron 36-group gamma-ray library in the AMPX-II Master Interface Format obtained processing ENDF/B-IV data by means of various AMPX-II System modules are presented in this note both for the more reprocessing aspects and features of the generated component files-neutrons, photon and secondary gamma-ray production cross sections. As far as the neutron data are concerned there is the avaibility of 186 data sets regarding most significant fission products. Results of the additional validation of the neutron data pertaining to eighteen benchmark experiments are also given. Some calculational tests on both neutron and coupled data emphasize the important role of the secondary gamma-ray data in nuclear criticality safety calculations

  4. Contact angle study on the activation mechanisms of sphalerite with Cu(II) and Pb(II); Estudio de los mecanismos de activacion de la esfalerita con Cu(II) y Pb(II)

    Energy Technology Data Exchange (ETDEWEB)

    Davila Pulido, G. I.; Uribe Salas, A.

    2011-07-01

    This article presents results of an experimental study on the sphalerite activation with Cu(II) and Pb(II), whose main objective was to investigate the activation mechanisms and to evaluate the magnitude of the hydrophobization achieved with both chemical species. The hydrophobicity acquired by the mineral due to the interaction with the activator and collector (sodium isopropyl xanthate) is characterized making use of the contact angle technique. The results show that Cu(II) replaces the Zn of the external layers of the mineral, promoting the sulfide (S{sup 2}-) oxidation to produce a mixture of CuS, Cu{sub 2}S and S{sup o}, of hydrophobic nature. The subsequent interaction with xanthate increases the hydrophobicity of the mineral surface. In turn, Pb(II) activation of sphalerite is due to the formation of a PbS layer that reacts with xanthate to produce hydrophobic species (e.g., PbX{sub 2}). It is also observed that the hydrophobicity of sphalerite activated with Pb(II) is favored under air atmospheres, as compared to that obtained under nitrogen atmospheres. It is concluded that the hydrophobicity achieved by lead activation may be of the same order of magnitude to that deliverately induced by copper activation. (Author) 11 refs.

  5. Design and development of cryo-module test system for 1.3 GHz LCLS-II cryomodule

    International Nuclear Information System (INIS)

    Khunt, A.C.S.; Anupam Kumar Sinha, B.; Aravind, T.C.; Mishra, D.V.K.; Sinha, E.A.K.; Mukesh Goyal, F.; Tejas Rane, G.

    2015-01-01

    Cryomodule Test System (CMTS) is a major cryogenic system designed and developed at Centre for Design and Manufacture (CDM), BARC under Indian Institutions and Fermi Lab Collaboration (IIFC). It is necessary test bed to measure the performance of superconducting RF cavities in Cryomodule. CMTS is required to test 1.3 GHz LCLS-II Cryomodule for Stanford Linear Accelerator Centre (SLAC), USA. Feed Cap and End Cap sub systems of Cryomodule Test System (CMTS) is designed and developed at CDM, BARC. Feed cap and End cap are 2K liquid helium distribution system for LCLS-II RF Cavity Bath and insulated by intermediate radiation shields maintained at 5K and 40K and Multilayer Insulation. The whole distribution system is enclosed in horizontal vacuum shells of approximately 1100 mm in diameter and 3000 mm in total length. This development was very challenging as many design considerations and decisions for 2K cryogenic requirements have been made and implemented. Also intricate mounting of ceramic sensors both internally and externally (surface mounted) for very low temperature measurements, low temperature epoxy bonding and multi-layer insulation wrapping were successfully completed. (author)

  6. Studies on nickel (II and palladium (II complexes with some tetraazamacrocycles containing tellurium

    Directory of Open Access Journals (Sweden)

    Rathee Nitu

    2012-01-01

    Full Text Available The synthesis of 10-membered and 12-membered tellurium containing tetraazamacrocyclic complexes of divalent nickel and palladium by template condensation of diaryltellurium dichlorides, (aryl = p-hydroxyphenyl, 3-methyl-4-hydroxyphenyl, p-methoxyphenyl with 1,2-diaminoethane and 1,3-diaminopropane in the presence of metal dichloride is reported. The resulting complexes have been subjected to elemental analyses, magnetic measurements, electronic absorption, infra-red, and proton magnetic resonance spectral studies. The formation of proposed macrocyclic skeletons and their donor sites have been identified on the basis of spectral studies. Distorted octahedral structure for the nickel complexes in the solid state and squareplanar structure for the palladium complexes have been suggested.

  7. Biomechanical testing of isolated bones: holographic study

    Science.gov (United States)

    Silvennoinen, Raimo; Nygren, Kaarlo; Karna, Markku

    1992-08-01

    Holographic nondestructive testing (HNDT) is used to investigate the complex structures of bones of various shapes and sizes subjected to forces. Three antlered deer skulls of different species were investigated and significant species-specific differences were observed. The HNDT method was also used to verify the advanced healing of an osteosynthetized sheep jawbone. Radioulnar bones of a normal and an orphaned moose calf were subjected to a bending test. The undernourished calf showed torsio displacement combined with the bending of the bone, which was not seen in the normal calf. The effects of the masticatory forces on the moose skull surface were studied by simulating masseter muscle contractions with jawbones in occlusion. The fringe patterns showed fast-moving bone surfaces on the naso- maxillo-lacrimal region.

  8. BACEKO II. Flow-through, open-front and saturation tests of pre-compacted backfill blocks in a quarter-scale test tunnel

    International Nuclear Information System (INIS)

    Keski-Kuha, E.; Nemlander, R.; Koho, P.

    2013-11-01

    The series of tests performed in BACEKO II project examined three different block materials for potential use in backfilling the repository; Friedland clay, 40/60-mixture of bentonite (40 %) and crushed rock (60 %) and Milos B clay in conjunction with pellet materials Cebogel QSE and Milos B clay. The testing program consisted of 9 tests, that continued the 1/4-scale tests executed in BACEKO 2008. The block backfilling degree of the 1/4-scale test tunnels was 73.8 % which was consistent with the material ratios associated with filling a repository tunnel having a 10 % over-excavation ratio. Some of these tests were conducted using a restraint installed at the front face of the setup and open-front tests were subsequently added in order to establish the time span which an open backfill front can remain stable should an interruption in the backfilling process occur. Additionally one flow-through test with higher salinity water (7 % TDS versus the 3,5 % TDS used in all other tests), was performed for an assembly constructed using Friedland clay. The rate of test assembly, consumption of materials and achieved densities were all monitored. During the tests, the erosion rates, progression of saturation and development of total pressure were monitored. In disassembling the tests, samples were collected for gravimetric water content measurement, the erosion pathways were identified and the sections were photographed with an infrared camera to illustrate the moister areas in the backfill. The greatest amounts of eroded material were observed in open-front tests where exiting water removed clay from the face of the backfill and formed a deepening channel in the block backfill. The open-front tests remained stable only until the outflow emerged. The properties of the pellet layer depend on the as-placed conditions which were operatordependant and also affect the outflow times. There was not much difference in the amount of erosion observed for the different block materials

  9. Two-dimensional thermal-hydraulic behavior in core in SCTF Core-II cold leg injection tests

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Okubo, Tsutomu; Ohnuki, Akira; Abe, Yutaka; Adachi, Hiromichi

    1985-07-01

    Major purpose of the Slab Core Test Program is to investigate the two-dimensional thermal-hydraulic behavior in the core during the reflood phase in a PWR-LOCA. In order to investigate the effects of radial power profile, three cold leg injection tests with different radial power profiles under the same total heating power and core stored energy were performed by using the Slab Core Test Facility (SCTF) Core-II. It was revealed by comparing these three tests that the heat transfer was enhanced in the higher power bundles and degraded in the lower power bundles in the non-uniform radial power profile tests. The turnaround temperature in the high power bundles were evaluated to be reduced by about 40 to 120 K. On the other hand, a two-dimensional flow in the core was also induced by the non-uniform water accumulation in the upper plenum and the quench was delayed resultantly in the bundles corresponding to the peripheral bundles of a PWR. However, the effect of the non-uniform upper plenum water accumulation on the turnaround temperature was small because the effect dominated after the turnaround of the cladding temperature. Selected data from Tests S2-SH1, S2-SH2 and S2-O6 are also presented in this report. Some data from Tests S2-SH1 and S2-SH2 were compared with TRAC post-test calculations performed by the Los Alamos National Laboratory. (author)

  10. Statistically based reevaluation of PISC-II round robin test data

    International Nuclear Information System (INIS)

    Heasler, P.G.; Taylor, T.T.; Doctor, S.R.

    1993-05-01

    This report presents a re-analysis of an international PISC-II (Programme for Inspection of Steel Components, Phase 2) round-robin inspection results using formal statistical techniques to account for experimental error. The analysis examines US team performance vs. other participants performance,flaw sizing performance and errors associated with flaw sizing, factors influencing flaw detection probability, performance of all participants with respect to recently adopted ASME Section 11 flaw detection performance demonstration requirements, and develops conclusions concerning ultrasonic inspection capability. Inspection data were gathered on four heavy section steel components which included two plates and two nozzle configurations

  11. A characterization and optimization study of Gamble II as an X-ray bremsstrahlung source

    International Nuclear Information System (INIS)

    Oliphant, W.F.; Boller, J.R.; Brown, D.G.; Cooperstein, G.; Dozier, C.M.; Stephanakis, S.J.

    1982-01-01

    The adverse effects of radiation on solid state devices are strongly spectrum dependent. It is thus essential that the radiation spectrum from flash x-ray sources be available when they are used as facilities for testing electronic components. This paper describes a preliminary study in which previously developed computer codes were used to calculate the radiation spectrum produced by NRL's Gamble II pulsed power generator. To determine how well the calculated spectrum matched the experimental one, doses in CaF 2 -Mn TLD's were computed for the dosimeters placed behind various thicknesses of Cu and Pb filters and compared with the experimentally measured doses. Using a diode model that was consistent with presently understood electron beam behavior, a spectrum was generated which predicted TLD doses to within about 15% of the experimentally measured values

  12. Reconstructing solar magnetic fields from historical observations. II. Testing the surface flux transport model

    Science.gov (United States)

    Virtanen, I. O. I.; Virtanen, I. I.; Pevtsov, A. A.; Yeates, A.; Mursula, K.

    2017-07-01

    Aims: We aim to use the surface flux transport model to simulate the long-term evolution of the photospheric magnetic field from historical observations. In this work we study the accuracy of the model and its sensitivity to uncertainties in its main parameters and the input data. Methods: We tested the model by running simulations with different values of meridional circulation and supergranular diffusion parameters, and studied how the flux distribution inside active regions and the initial magnetic field affected the simulation. We compared the results to assess how sensitive the simulation is to uncertainties in meridional circulation speed, supergranular diffusion, and input data. We also compared the simulated magnetic field with observations. Results: We find that there is generally good agreement between simulations and observations. Although the model is not capable of replicating fine details of the magnetic field, the long-term evolution of the polar field is very similar in simulations and observations. Simulations typically yield a smoother evolution of polar fields than observations, which often include artificial variations due to observational limitations. We also find that the simulated field is fairly insensitive to uncertainties in model parameters or the input data. Due to the decay term included in the model the effects of the uncertainties are somewhat minor or temporary, lasting typically one solar cycle.

  13. Elliptical cross section fuel rod study II; Estudio de barras combustibles de seccion eliptica II

    Energy Technology Data Exchange (ETDEWEB)

    Taboada, H; Marajofsky, A [Comision Nacional de Energia Atomica, San Martin (Argentina). Unidad de Actividad Combustibles Nucleares

    1997-12-31

    In this paper it is continued the behavior analysis and comparison between cylindrical fuel rods of circular and elliptical cross sections. Taking into account the accepted models in the literature, the fission gas swelling and release were studied. An analytical comparison between both kinds of rod reveals a sensible gas release reduction in the elliptical case, a 50% swelling reduction due to intragranular bubble coalescence mechanism and an important swelling increase due to migration bubble mechanism. From the safety operation point of view, for the same linear power, an elliptical cross section rod is favored by lower central temperatures, lower gas release rates, greater gas store in ceramic matrix and lower stored energy rates. (author). 6 refs., 8 figs., 1 tab.

  14. An interaction of renin-angiotensin and kallikrein-kinin systems contributes to vascular hypertrophy in angiotensin II-induced hypertension: in vivo and in vitro studies.

    Directory of Open Access Journals (Sweden)

    Graziela S Ceravolo

    Full Text Available The kallikrein-kinin and renin-angiotensin systems interact at multiple levels. In the present study, we tested the hypothesis that the B1 kinin receptor (B1R contributes to vascular hypertrophy in angiotensin II (ANG II-induced hypertension, through a mechanism involving reactive oxygen species (ROS generation and extracellular signal-regulated kinase (ERK1/2 activation. Male Wistar rats were infused with vehicle (control rats, 400 ng/Kg/min ANG II (ANG II rats or 400 ng/Kg/min ANG II plus B1 receptor antagonist, 350 ng/Kg/min des-Arg(9-Leu(8-bradykinin (ANGII+DAL rats, via osmotic mini-pumps (14 days or received ANG II plus losartan (10 mg/Kg, 14 days, gavage - ANG II+LOS rats. After 14 days, ANG II rats exhibited increased systolic arterial pressure [(mmHg 184 ± 5.9 vs 115 ± 2.3], aortic hypertrophy; increased ROS generation [2-hydroxyethidium/dihydroethidium (EOH/DHE: 21.8 ± 2.7 vs 6.0 ± 1.8] and ERK1/2 phosphorylation (% of control: 218.3 ± 29.4 vs 100 ± 0.25]. B1R expression was increased in aortas from ANG II and ANG II+DAL rats than in aortas from the ANG II+LOS and control groups. B1R antagonism reduced aorta hypertrophy, prevented ROS generation (EOH/DHE: 9.17 ± 3.1 and ERK1/2 phosphorylation (137 ± 20.7% in ANG II rats. Cultured aortic vascular smooth muscle cells (VSMC stimulated with low concentrations (0.1 nM of ANG II plus B1R agonist exhibited increased ROS generation, ERK1/2 phosphorylation, proliferating-cell nuclear antigen expression and [H3]leucine incorporation. At this concentration, neither ANG II nor the B1R agonist produced any effects when tested individually. The ANG II/B1R agonist synergism was inhibited by losartan (AT1 blocker, 10 µM, B1R antagonist (10 µM and Tiron (superoxide anion scavenger, 10 mM. These data suggest that B1R activation contributes to ANG II-induced aortic hypertrophy. This is associated with activation of redox-regulated ERK1/2 pathway that controls aortic smooth muscle cells growth

  15. Treatability Study Pilot Test Operation Field Photos

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-01

    Photos in each group are in chronological order as captured: Group I Tank Platform Setup, November 14, 2017; Group II Tank Setup, November 15, 2017; Group III Aboveground Injestion System (AIS) Setup, November 20, 2017; Group IV Chemical Mixing, November 21, 2017; Group V KB-1 Bacteria Injection, November 27, 2017; Group VI Miscellaneous.

  16. Synthesis, characterization and antimicrobial studies of Cu(II) and ...

    African Journals Online (AJOL)

    chloroaniline were synthesized and characterized by solubility test, infrared spectra, conductivity measurement, magnetic susceptibility, metal-ligand ratio determination, and antimicrobial activity. The low molar conductance values range (16.

  17. Mutagenic effects of tributyltin and inorganic lead (Pb II on the fish H. malabaricus as evaluated using the comet assay and the piscine micronucleus and chromosome aberration tests

    Directory of Open Access Journals (Sweden)

    Ferraro Marcos Vinícius M.

    2004-01-01

    Full Text Available Genotoxicity studies on toxic metals and their organic compounds are very important, especially so in the investigation of the effects of these compounds on the aquatic environments where they tend to accumulate. The use of endemic aquatic organisms as biological sentinels has proved useful to environmental monitoring. We assessed the mutagenic potential of tributyltin (TBT and inorganic lead (PbII using samples of the fish Hoplias malabaricus (commonly called traíra using the comet assay and the piscine micronucleus and chromosome aberration tests. Eighteen H. malabaricus were acclimatized in three individual aquariums, each containing six fish, six fish being exposed to 0.3 mg/g of body weight (bw of TBT, six to 21 mg/g bw of PbII and six being used as controls. Exposure to TBT and PbII was achieved by feeding the fish every five days with Astyanax (a small fish that is part of the normal diet of H. malabaricus which had been injected with solutions of TBT, PbII or with water (the control group. After two months the H. malabaricus were sacrificed and their peripheral blood collected and subjected to the comet and micronucleus assays, the chromosome aberration assay being conducted using kidney-tissue. Although the comet assay showed now mutagenic effects at the lead concentrations used but encountered results with TBT, the micronucleus and chromosome aberrations assays both indicated that TBT and PbII are potentially mutagenic (p < 0.01, the micronucleus assay showing morphological alterations of the nucleus.

  18. In vitro tests for aerosol deposition II: IVIVCs for different dry powder inhalers in normal adults.

    Science.gov (United States)

    Delvadia, Renishkumar; Hindle, Michael; Longest, P Worth; Byron, Peter R

    2013-06-01

    A new in vitro test method for dry powder inhalers (DPIs) was recently found to be predictive of the published in vivo results for Budelin Novolizer. The present study was intended to assess the method's robustness by evaluating correlations between average drug deposition in vitro and in vivo from five different DPIs. In vitro drug deposition from five marketed DPIs was assessed in a realistic physical airway model of a "medium" sized adult in an experimental setup that allowed deposition to be characterized regionally for carefully selected simulated air flow rate versus time profiles. The DPIs studied were Spiriva(®) HandiHaler(®), Relenza(®) Diskhaler(®), Salbutamol Easyhaler(®), Pulmicort(®) Turbuhaler(®), and Foradil(®) Aerolizer(®). In vitro regional deposition results were compared with those reported in the literature in order to create in vitro-in vivo correlations (IVIVCs) for each inhaler. Mean percent total lung deposition (TLD ± SD) in vitro for Spiriva HandiHaler, Relenza Diskhaler, Salbutamol Easyhaler, Pulmicort Turbuhaler, and Foradil Aerolizer were 17.3 ± 1.2, 22.6 ± 1.1, 29.0 ± 1.1, 28.0 ± 3.0, and 21.7 ± 1.2, respectively. These results showed excellent agreement with reported in vivo values, with absolute prediction errors in TLD of ≤ 2% for all DPIs except Relenza Diskhaler. Similarly, in vitro mouth-throat and device deposition results were stoichiometrically comparable to those reported in vivo for all DPIs except Relenza Diskhaler and Turbuhaler. Inspection of the scintigraphy studies for Relenza Diskhaler and Turbohaler revealed possible problems with powder labeling and result interpretation in their in vivo clinical assessments. A characteristic physical airway model representing a medium-sized adult, when coupled to carefully chosen characteristic inhalation maneuvers used in the clinic, produced results that correlated with regional drug deposition estimates from scintigraphy across a group of different DPIs.

  19. Test results of distributed ion pump designs for the PEP-II Asymmetric B-Factory collider

    Energy Technology Data Exchange (ETDEWEB)

    Calderon, M.; Holdener, F.; Peterson, D. [Lawrence Livermore National Lab., CA (United States)] [and others

    1994-07-01

    The testing facility measurement methods and results of prototype distributed ion pump (DIP) designs for the PEP-II B-Factory High Energy Ring are presented. Two basic designs with 5- or 7-anode plates were tested at LLNL with penning cell sizes of 15, 18, and 21 mm. Direct comparison of 5- and 7-plate anodes with 18 mm holes shows increased pumping speed with the 7-plate design. The 5-plate, 18 mm and 7-plate, 15 mm designs both gave an average pumping speed of 135 1/s/m at 1 {times} 10{sup {minus}8} Torr nitrogen base pressure in a varying 0.18 T peak B-field. Comparison of the three hole sizes indicates that cells smaller than the 15 mm tested can be efficiently used to obtain higher pumping speeds for the same anode plate sizes used.

  20. Test results of distributed ion pump designs for the PEP-II Asymmetric B-Factory collider

    International Nuclear Information System (INIS)

    Calderon, M.; Holdener, F.; Peterson, D.

    1994-07-01

    The testing facility measurement methods and results of prototype distributed ion pump (DIP) designs for the PEP-II B-Factory High Energy Ring are presented. Two basic designs with 5- or 7-anode plates were tested at LLNL with penning cell sizes of 15, 18, and 21 mm. Direct comparison of 5- and 7-plate anodes with 18 mm holes shows increased pumping speed with the 7-plate design. The 5-plate, 18 mm and 7-plate, 15 mm designs both gave an average pumping speed of 135 1/s/m at 1 x 10 -8 Torr nitrogen base pressure in a varying 0.18 T peak B-field. Comparison of the three hole sizes indicates that cells smaller than the 15 mm tested can be efficiently used to obtain higher pumping speeds for the same anode plate sizes used

  1. Shock Isolation Elements Testing for High Input Loadings. Volume II. Foam Shock Isolation Elements.

    Science.gov (United States)

    SHOCK ABSORBERS ), (*GUIDED MISSILE SILOS, SHOCK ABSORBERS ), (*EXPANDED PLASTICS, (*SHOCK(MECHANICS), REDUCTION), TEST METHODS, SHOCK WAVES, STRAIN(MECHANICS), LOADS(FORCES), MATHEMATICAL MODELS, NUCLEAR EXPLOSIONS, HARDENING.

  2. Computational Modeling in Support of High Altitude Testing Facilities, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Simulation technology plays an important role in propulsion test facility design and development by assessing risks, identifying failure modes and predicting...

  3. Extreme gravity tests with gravitational waves from compact binary coalescences: (II) ringdown

    Science.gov (United States)

    Berti, Emanuele; Yagi, Kent; Yang, Huan; Yunes, Nicolás

    2018-05-01

    The LIGO/Virgo detections of binary black hole mergers marked a watershed moment in astronomy, ushering in the era of precision tests of Kerr dynamics. We review theoretical and experimental challenges that must be overcome to carry out black hole spectroscopy with present and future gravitational wave detectors. Among other topics, we discuss quasinormal mode excitation in binary mergers, astrophysical event rates, tests of black hole dynamics in modified theories of gravity, parameterized "post-Kerr" ringdown tests, exotic compact objects, and proposed data analysis methods to improve spectroscopic tests of Kerr dynamics by stacking multiple events.

  4. Feasibility Study on a Neutral Beam Diagnostic Injector for TJ-II

    International Nuclear Information System (INIS)

    McCarthy, K. J.; Balbin, R.; Lopez-Fraguas, A.

    2003-01-01

    A diagnostic neutral beam system is proposed for the TJ-II stellarator. The main goal of installing such a system in TJ-II is to increase the signal to noise ratio and provide spatial resolution in diagnostic systems based on Charge Exchange Recombination Spectroscopy and Neutral Particle Analysis, while also opening up new opportunities for physics studies in this magnetically confined plasma device. After outlining the unique characteristics of the TJ-II and reviewing available diagnostic injector systems, the compact system selected for TJ-II is presented together with estimates of the resulting increased signal levels Finally other important aspects are discussed, in particular its location and orientation, as well as possible solutions to avoid perturbing the TJ-II magnetic configurations in the heliac device. (Author) 31 refs

  5. Feasibility Study on a Neutral Beam Diagnostic Injector for TJ-II

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, K. J.; Balbin, R.; Lopez-Fraguas, A.

    2003-07-01

    A diagnostic neutral beam system is proposed for the TJ-II stellarator. The main goal of installing such a system in TJ-II is to increase the signal to noise ratio and provide spatial resolution in diagnostic systems based on Charge Exchange Recombination Spectroscopy and Neutral Particle Analysis, while also opening up new opportunities for physics studies in this magnetically confined plasma device. After outlining the unique characteristics of the TJ-II and reviewing available diagnostic injector systems, the compact system selected for TJ-II is presented together with estimates of the resulting increased signal levels Finally other important aspects are discussed, in particular its location and orientation, as well as possible solutions to avoid perturbing the TJ-II magnetic configurations in the heliac device. (Author) 31 refs.

  6. Advanced Demonstration and Test Reactor Options Study

    Energy Technology Data Exchange (ETDEWEB)

    Petti, David Andrew [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hill, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Gehin, J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gougar, Hans David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Strydom, Gerhard [Idaho National Lab. (INL), Idaho Falls, ID (United States); Heidet, F. [Argonne National Lab. (ANL), Argonne, IL (United States); Kinsey, J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Grandy, Christopher [Argonne National Lab. (ANL), Argonne, IL (United States); Qualls, A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Brown, Nicholas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Powers, J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoffman, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Croson, D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    Global efforts to address climate change will require large-scale decarbonization of energy production in the United States and elsewhere. Nuclear power already provides 20% of electricity production in the United States (U.S.) and is increasing in countries undergoing rapid growth around the world. Because reliable, grid-stabilizing, low emission electricity generation, energy security, and energy resource diversity will be increasingly valued, nuclear power’s share of electricity production has a potential to grow. In addition, there are non electricity applications (e.g., process heat, desalination, hydrogen production) that could be better served by advanced nuclear systems. Thus, the timely development, demonstration, and commercialization of advanced nuclear reactors could diversify the nuclear technologies available and offer attractive technology options to expand the impact of nuclear energy for electricity generation and non-electricity missions. The purpose of this planning study is to provide transparent and defensible technology options for a test and/or demonstration reactor(s) to be built to support public policy, innovation and long term commercialization within the context of the Department of Energy’s (DOE’s) broader commitment to pursuing an “all of the above” clean energy strategy and associated time lines. This planning study includes identification of the key features and timing needed for advanced test or demonstration reactors to support research, development, and technology demonstration leading to the commercialization of power plants built upon these advanced reactor platforms. This planning study is consistent with the Congressional language contained within the fiscal year 2015 appropriation that directed the DOE to conduct a planning study to evaluate “advanced reactor technology options, capabilities, and requirements within the context of national needs and public policy to support innovation in nuclear energy

  7. Advanced Demonstration and Test Reactor Options Study

    International Nuclear Information System (INIS)

    Petti, David Andrew; Hill, R.; Gehin, J.; Gougar, Hans David; Strydom, Gerhard; Heidet, F.; Kinsey, J.; Grandy, Christopher; Qualls, A.; Brown, Nicholas; Powers, J.; Hoffman, E.; Croson, D.

    2017-01-01

    Global efforts to address climate change will require large-scale decarbonization of energy production in the United States and elsewhere. Nuclear power already provides 20% of electricity production in the United States (U.S.) and is increasing in countries undergoing rapid growth around the world. Because reliable, grid-stabilizing, low emission electricity generation, energy security, and energy resource diversity will be increasingly valued, nuclear power's share of electricity production has a potential to grow. In addition, there are non electricity applications (e.g., process heat, desalination, hydrogen production) that could be better served by advanced nuclear systems. Thus, the timely development, demonstration, and commercialization of advanced nuclear reactors could diversify the nuclear technologies available and offer attractive technology options to expand the impact of nuclear energy for electricity generation and non-electricity missions. The purpose of this planning study is to provide transparent and defensible technology options for a test and/or demonstration reactor(s) to be built to support public policy, innovation and long term commercialization within the context of the Department of Energy's (DOE's) broader commitment to pursuing an 'all of the above' clean energy strategy and associated time lines. This planning study includes identification of the key features and timing needed for advanced test or demonstration reactors to support research, development, and technology demonstration leading to the commercialization of power plants built upon these advanced reactor platforms. This planning study is consistent with the Congressional language contained within the fiscal year 2015 appropriation that directed the DOE to conduct a planning study to evaluate 'advanced reactor technology options, capabilities, and requirements within the context of national needs and public policy to support innovation in nuclear energy'. Advanced reactors are

  8. The possibility to increase the rated output as a result of index tests performed in Iron Gates II- Romania

    Science.gov (United States)

    Novac, D.; Pantelimon, D.; Popescu, E.

    2010-08-01

    The Index Tests have been used for many years to obtain the optimized cam corellation between wicket gates and runner blades for double regulated turbines (Kaplan, bulb). The cam is based on homologous model tests and is verified by site measurements, as model tests generally do not reproduce the exact intake configuration. Index Tests have also a considerable importance for checking of the relative efficiency curve of all type of turbines and can demonstrate if the prototype efficiency curve at plant condition has the shape expected from the test of the homologues model. During the Index Tests measurements the influence of all losses at multiple points of turbine operation can be proved. This publication deals with an overview on the Index Tests made after modernization of large bulb units in Iron Gates II - Romania. These field tests, together with the comparative, fully homologous tests for the new hydraulic shape of the runner blades have confirmed the smooth operational behavior and the guaranteed performance. Over the whole "guaranteed operating range" for H = 8m, the characteristic of the Kaplan curve (enveloping curve to the proppeler curves), agreed very well to the predicted efficiency curve from the hydraulic prototype hill chart. The new cam correlation have been determined for different head and realised in the governor, normally based on model tests. The guaranteed, maximum turbine output for H = 7,8m is specified with 32, 5 MW. The maximum measured turbine output during the Index Tests on cam operation was 35,704 MW at the net head of 7,836 m. This coresponds to 35,458 MW for the specified head H= 7, 8 m. All these important improvements ensure a significant increase of annual energy production without any change of the civil construction and without increasing the runner diameter. Also the possibility to increase the turbine rated output is evident.

  9. The possibility to increase the rated output as a result of index tests performed in Iron Gates II- Romania

    International Nuclear Information System (INIS)

    Novac, D; Pantelimon, D; Popescu, E

    2010-01-01

    The Index Tests have been used for many years to obtain the optimized cam correlation between wicket gates and runner blades for double regulated turbines (Kaplan, bulb). The cam is based on homologous model tests and is verified by site measurements, as model tests generally do not reproduce the exact intake configuration. Index Tests have also a considerable importance for checking of the relative efficiency curve of all type of turbines and can demonstrate if the prototype efficiency curve at plant condition has the shape expected from the test of the homologues model. During the Index Tests measurements the influence of all losses at multiple points of turbine operation can be proved. This publication deals with an overview on the Index Tests made after modernization of large bulb units in Iron Gates II - Romania. These field tests, together with the comparative, fully homologous tests for the new hydraulic shape of the runner blades have confirmed the smooth operational behavior and the guaranteed performance. Over the whole 'guaranteed operating range' for H = 8m, the characteristic of the Kaplan curve (enveloping curve to the propeller curves), agreed very well to the predicted efficiency curve from the hydraulic prototype hill chart. The new cam correlation have been determined for different head and realised in the governor, normally based on model tests. The guaranteed, maximum turbine output for H = 7,8m is specified with 32, 5 MW. The maximum measured turbine output during the Index Tests on cam operation was 35,704 MW at the net head of 7,836 m. This corresponds to 35,458 MW for the specified head H= 7, 8 m. All these important improvements ensure a significant increase of annual energy production without any change of the civil construction and without increasing the runner diameter. Also the possibility to increase the turbine rated output is evident.

  10. The possibility to increase the rated output as a result of index tests performed in Iron Gates II- Romania

    Energy Technology Data Exchange (ETDEWEB)

    Novac, D; Pantelimon, D [Hidroelectrica - SH Portile de Fier, Str. I.G. Bibicescu Nr.2, Drobeta Turnu Severin, RO - 220103 (Romania); Popescu, E, E-mail: dragos.novac@hidroelectrica.r [Hidroelectrica Bucuresti, Str. C-tin Nacu Nr.3, Bucuresti, RO - 020995 (Romania)

    2010-08-15

    The Index Tests have been used for many years to obtain the optimized cam correlation between wicket gates and runner blades for double regulated turbines (Kaplan, bulb). The cam is based on homologous model tests and is verified by site measurements, as model tests generally do not reproduce the exact intake configuration. Index Tests have also a considerable importance for checking of the relative efficiency curve of all type of turbines and can demonstrate if the prototype efficiency curve at plant condition has the shape expected from the test of the homologues model. During the Index Tests measurements the influence of all losses at multiple points of turbine operation can be proved. This publication deals with an overview on the Index Tests made after modernization of large bulb units in Iron Gates II - Romania. These field tests, together with the comparative, fully homologous tests for the new hydraulic shape of the runner blades have confirmed the smooth operational behavior and the guaranteed performance. Over the whole 'guaranteed operating range' for H = 8m, the characteristic of the Kaplan curve (enveloping curve to the propeller curves), agreed very well to the predicted efficiency curve from the hydraulic prototype hill chart. The new cam correlation have been determined for different head and realised in the governor, normally based on model tests. The guaranteed, maximum turbine output for H = 7,8m is specified with 32, 5 MW. The maximum measured turbine output during the Index Tests on cam operation was 35,704 MW at the net head of 7,836 m. This corresponds to 35,458 MW for the specified head H= 7, 8 m. All these important improvements ensure a significant increase of annual energy production without any change of the civil construction and without increasing the runner diameter. Also the possibility to increase the turbine rated output is evident.

  11. Development of production technology for bio diesel fuel and feasibility test of bio diesel engine (II)

    Energy Technology Data Exchange (ETDEWEB)

    Na, Y J; Ju, U S; Park, Y C [National Kyung Sang University (Korea, Republic of)

    1996-02-01

    At the beginning of the 21 st century two urgent tasks which our global countries would face with could be the security of the alternative energy source as a preparation against the fossil energy exhaustion and the development of the clean energy source to protect the environment from pollution. The above two problems should be solved together. The bio diesel oil which is made by methylesterfication of bio oil has very low sulfur content than does the diesel oil. Therefore, there is a great possibility to solve the pollution problem caused by the exhaust gas from diesel engine vehicles. So, bio oil has been attracted with attentions as an alternative and clean energy source. Advanced countries began early to develop the bio diesel oil suitable to their respective conditions. Recently their production stage have reached to the commercial level partially. The sudden increase of energy demand followed by a rapid growth of industry and the serious situation about the environmental pollution caused by the exhaust has from diesel engine vehicles occupying 42% of distribution among all vehicles have called attention of our government to consider the importance of alternative and clean energy sources for the future on the national scale. This study is consisted of three main parts; - The development of production technology for bio diesel oil. - The development of the atomization improvement method and nozzle for high viscous vegetable oils. - Feasibility test of bio diesel engine. (author) 119 refs., 52 tabs., 88 figs.

  12. Specificity of the Acute Tryptophan and Tyrosine plus Phenylalanine Depletion and Loading Tests Part II:

    Directory of Open Access Journals (Sweden)

    Abdulla A.-B. Badawy

    2010-01-01

    Full Text Available Current formulations for acute tryptophan (Trp or tyrosine (Tyr plus phenylalanine (Phe depletion and loading cause undesirable decreases in ratios of Trp or Tyr + Phe to competing amino acids (CAA, thus undermining the specificities of these tests. Branched-chain amino acids (BCAA cause these unintended decreases, and lowering their content in a new balanced control formulation in the present study led to normalization of all ratios. Four groups (n = 12 each of adults each received one of four 50 g control formulations, with 0% (traditional, 20%, 30%, or 40% less of the BCAA. The free and total [Trp]/[CAA] and [Phe + Tyr]/[BCAA+ Trp] ratios all decreased significantly during the first 5 h following the traditional formulation, but were fully normalized by the formulation containing 40% less of the BCAA. We recommend the latter as a balanced control formulation and propose adjustments in the depletion and loading formulations to enhance their specificities for 5-HT and the catecholamines.

  13. Studies of the labelling of human serum albumin with 99mTc using Sn(II) tartrate and Sn(II)Cl2 as reducing agents

    International Nuclear Information System (INIS)

    El-Kolaly, M.T.; El-Asrag, H.A.; El-Wetery, A.S.; El-Mohty, A.A.

    1990-01-01

    A comparative study has been carried out on the effect of Sn(II) tartrate and Sn(II)Cl 2 on the labelling efficiency and tissue distribution of 99m Tc-human serum albumin. The effect of reductant content, reaction time (incubation time), albumin content, pH, and ascorbic acid on the efficiency of labelling and the tissue distribution of the labelled albumin has been investigated. The percentage of labelling was determined by paper and thin layer radiochromatography. Ascorbic acid shows no effect on either labelling efficiency or tissue distribution of 99m Tc-HSA prepared by Sn(II) tartrate or Sn(II)Cl 2 . (author)

  14. Plasma-wall Interaction Studies in the Start-up Phase of TJ-II

    International Nuclear Information System (INIS)

    De la Cal, E.; Tabares, F.L.; Tafalla, D.

    1998-01-01

    The aim of this work is to present some first plasma-wall interaction studies made during the first experimental campaign of TJ-II. The different sections contain independent contributions presented orally in the fusion division of the Euratom-Ciemat association during 1998: I. Density limit during the start-up phase of TJ-II : are we limited by radiation?. II. Temporal evolution of oxygen in the plasma during an experimental day. III. The contribution of helium to the plasma electron density IV. First studies of the S.O.L. diffusion coefficient and its dependence with the boundary plasma parameters. (Author) 3 refs

  15. Making System Dynamics Cool II : New Hot Teaching and Testing Cases of Increasing Complexity

    NARCIS (Netherlands)

    Pruyt, E.

    2010-01-01

    This follow-up paper presents several actual cases for testing and teaching System Dynamics. The cases were developed between April 2009 and January 2010 for the Introductory System Dynamics courses at Delft University of Technology in the Netherlands. They can be used for teaching and testing

  16. Test of the rem-counter WENDI-II from Eberline in different energy-dispersed neutron fields

    International Nuclear Information System (INIS)

    Gutermuth, F.; Radon, T.; Fehrenbacher, G.; Siekmann, R.

    2004-03-01

    The neutron rem-counter WENDI-II from Eberline was tested in high-energy particle accelerator produced neutron fields. A radioactive 241 Am-Be(αn) source was used as a reference. The experimentally determined responses are compared to Monte-Carlo simulations of the response function done by R. H. Olsher et al. (2000). The energy spectra of the accelerator produced neutron fields were determined employing Monte-Carlo simulations, too. According to the simulations done by C. Birattari et al. (1998) and in this work these neutron fields exhibit large contributions to the ambient dose equivalent resulting from neutrons with kinetic energy of more than 20 MeV up to a few 100 MeV. The WENDI-II detector proved to show a response of approximately 3.10 9 pulses per Sievert ambient dose equivalent. Considering the experimental and statistical uncertainties the results are consistent with the assumption that the dose response of the WENDI-II reproduces quite accurately the function for the ambient dose equivalent of the ICRP 74

  17. Construction and test of the first Belle II SVD ladder implementing the origami chip-on-sensor design

    International Nuclear Information System (INIS)

    Irmler, C.; Bauer, A.; Bergauer, T.; Adamczyk, K.; Bacher, S.; Aihara, H.; Angelini, C.; Batignani, G.; Bettarini, S.; Bosi, F.; Aziz, T.; Babu, V.; Bahinipati, S.; Barberio, E.; Baroncelli, Ti.; Baroncelli, To.; Basith, A.K.; Behera, P.K.; Bhuyan, B.; Bilka, T.

    2016-01-01

    The Belle II Silicon Vertex Detector comprises four layers of double-sided silicon strip detectors (DSSDs), consisting of ladders with two to five sensors each. All sensors are individually read out by APV25 chips with the Origami chip-on-sensor concept for the central DSSDs of the ladders. The chips sit on flexible circuits that are glued on the top of the sensors. This concept allows a low material budget and an efficient cooling of the chips by a single pipe per ladder. We present the construction of the first SVD ladders and results from precision measurements and electrical tests

  18. Linear and non-linear analyses of Conner's Continuous Performance Test-II discriminate adult patients with attention deficit hyperactivity disorder from patients with mood and anxiety disorders.

    Science.gov (United States)

    Fasmer, Ole Bernt; Mjeldheim, Kristin; Førland, Wenche; Hansen, Anita L; Syrstad, Vigdis Elin Giæver; Oedegaard, Ketil J; Berle, Jan Øystein

    2016-08-11

    Attention Deficit Hyperactivity Disorder (ADHD) is a heterogeneous disorder. Therefore it is important to look for factors that can contribute to better diagnosis and classification of these patients. The aims of the study were to characterize adult psychiatric out-patients with a mixture of mood, anxiety and attentional problems using an objective neuropsychological test of attention combined with an assessment of mood instability. Newly referred patients (n = 99; aged 18-65 years) requiring diagnostic evaluation of ADHD, mood or anxiety disorders were recruited, and were given a comprehensive diagnostic evaluation including the self-report form of the cyclothymic temperament scale and Conner's Continuous Performance Test II (CPT-II). In addition to the traditional measures from this test we have extracted raw data and analysed time series using linear and non-linear mathematical methods. Fifty patients fulfilled criteria for ADHD, while 49 did not, and were given other psychiatric diagnoses (clinical controls). When compared to the clinical controls the ADHD patients had more omission and commission errors, and higher reaction time variability. Analyses of response times showed higher values for skewness in the ADHD patients, and lower values for sample entropy and symbolic dynamics. Among the ADHD patients 59 % fulfilled criteria for a cyclothymic temperament, and this group had higher reaction time variability and lower scores on complexity than the group without this temperament. The CPT-II is a useful instrument in the assessment of ADHD in adult patients. Additional information from this test was obtained by analyzing response times using linear and non-linear methods, and this showed that ADHD patients with a cyclothymic temperament were different from those without this temperament.

  19. Column dynamic studies and breakthrough curve analysis for Cd(II) and Cu(II) ions adsorption onto palm oil boiler mill fly ash (POFA).

    Science.gov (United States)

    Aziz, Abdul Shukor Abdul; Manaf, Latifah Abd; Man, Hasfalina Che; Kumar, Nadavala Siva

    2014-01-01

    This paper investigates the adsorption characteristics of palm oil boiler mill fly ash (POFA) derived from an agricultural waste material in removing Cd(II) and Cu(II) from aqueous solution via column studies. The performance of the study is described through the breakthrough curves concept under relevant operating conditions such as column bed depths (1, 1.5, and 2 cm) and influent metal concentrations (5, 10, and 20 mg/L). The Cd(II) and Cu(II) uptake mechanism is particularly bed depth- and concentration-dependant, favoring higher bed depth and lower influent metal concentration. The highest bed capacity of 34.91 mg Cd(II)/g and 21.93 mg Cu(II)/g of POFA was achieved at 20 mg/L of influent metal concentrations, column bed depth of 2 cm, and flow rate of 5 mL/min. The whole breakthrough curve simulation for both metal ions were best described using the Thomas and Yoon–Nelson models, but it is apparent that the initial region of the breakthrough for Cd(II) was better described using the BDST model. The results illustrate that POFA could be utilized effectively for the removal of Cd(II) and Cu(II) ions from aqueous solution in a fixed-bed column system.

  20. Design, construction and tests of the power crowbar and predischarge circuit of the SPICA II experiment

    International Nuclear Information System (INIS)

    Ingen, A.M. van; Manintveld, P.; Sterk, A.B.

    1983-01-01

    A 28 Farad, 1.8 MJ electrolytic capacitor power-crowbar battery and a flexible predischarge circuit for the SPICA II screw-pinch experiment is described. The battery is capable of delivering the toroidal and poloidal currents of more than 2.5 MA, during at least 1 ms after crowbarring of the high-voltage capacitor banks. To obtain a low short-circuit impedance a very compact construction was chosen, which resulted in seven modules of about 1 m 3 each, Rsub(i) = 100 μΩ, Lsub(i) = 7 nH, connected by plate systems to the main circuit. The predischarge circuit consists of a fast capacitor bank to start the predischarge and a slow circuit with a clamp switch to preheat the discharge. (author)

  1. Evaluation of the ceramographies of the KNK II/1 test zone fuel assembly NY-202-IA

    International Nuclear Information System (INIS)

    Geier, F.

    1983-12-01

    From the 211 fuel pins of the KNK II/1 fuel assembly NY-202-IA six intact fuel pins were selected in addition to the defective pin for destructive post-irradiation examinations in the Hot Cells of the KfK Karlsruhe. The assembly had been unloaded due to a pin failure after 192 equivalent full-power days and a maximum burnup of 5.4 %. The main aspect of these investigations was to record the fuel and fuel pin behavior and thus to allow a comparison of the status before and after irradiation. The results can also be used for comparative calculations and adaptations of existing calculational models. This report documents in detailed form the results of the fuel and fuel pin examinations [de

  2. Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, Richard M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gowri, Krishnan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-15

    Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and included test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6

  3. Gestational Age, Infant Birth Weight, and Subsequent Risk of Type 2 Diabetes in Mothers: Nurses' Health Study II

    Science.gov (United States)

    ... Subsequent Risk of Type 2 Diabetes in Mothers: Nurses’ Health Study II Navigate This Article Abstract Introduction ... Table 1. Pregnancy Complications and Diabetes Risk Factors, Nurses’ Health Study II, 1989–2005 Characteristic All Births ...

  4. Fast breeder fuel pin bundle tests in the KNK II-reactor

    International Nuclear Information System (INIS)

    Haefner, H.E.; Bojarsky, E.

    1986-11-01

    Three variants of ring elements with test bundles will be reported in this paper: In a first step a ring element was built with a permanently integrated test bundle (19 carbide pins of the Karlsruhe reference concept) while the proven fuel element components have been largely maintained. This irradiation will be completed in autumn 1986 after 380 full power days of operation. The central topic of this paper will be the technique of reloadable ring elements with replaceable test bundles. A first experiment, TOAST, is in preparation. For this experiment, above all the components of the fuel element head and foot had to be newly developed and tested. A special version of double-walled replaceable test bundles to be used in the TETRA temperature transient experiments will be briefly mentioned. It is envisaged in these experiments to vary in a defined manner the coolant flow at remotely assembled test bundles consisting of 19 KNK pins each having undergone a high burnup and to use a measuring and control plug placed on the test bundle so that a variety of fuel pin temperature programs can be realized. Finally, some additional aspects of bundle design will be indicated. (orig./GL) [de

  5. Youth Attitude Tracking Study II Wave 17 -- Fall 1986.

    Science.gov (United States)

    1987-06-01

    11111.6 MICROCOPY F LSOLUTION TEST CHART TINAL RUfl[A( , 1 TN ; [. iq . PHOTOGRAPH THIS SHEET 00U qJ. LEVEL INVENTORY 00 DOCIENT IDENTI . CA6 N IThldamm...the younger market groups. An expanded treatment of the effect of economic conditions on propensity for young males and young females utilizing average

  6. Automating Exams for a Statistics Course: II. A Case Study.

    Science.gov (United States)

    Michener, R. Dean; And Others

    A specific application of the process of automating exams for any introductory statistics course is described. The process of automating exams was accomplished by using the Statistical Test Item Collection System (STICS). This system was first used to select a set of questions based on course requirements established in advance; afterward, STICS…

  7. Type II diabetes and personality; a study to explore other psychosomatic aspects of diabetes

    OpenAIRE

    Esmaeilinasab, Maryam; Ebrahimi, Mehdi; Mokarrar, Mohsen Heidari; Rahmati, Leila; Mahjouri, Mohammad Yoosef; Arzaghi, Seyed Masoud

    2016-01-01

    Background As one of the most common chronic diseases, diabetes and its control are affected by the patients? psychological and spiritual attributes. The present study investigates the relationship between glycemic control in patients with type II diabetes and personality traits, defense mechanisms and spirituality. Method The present cross-sectional study was conducted on 400 Iranian patients with type II diabetes, 64% were men. Participants completed the NEO Personality Inventory, the Defen...

  8. {open_quotes}O{close_quotes} ring sealed process tube, Phase II, test project

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.E.

    1951-04-09

    The {open_quotes}O{close_quotes} ring seal has been proposed to replace the van stone flange and the bellows thermal expansion assembly currently used on the existing Hanford piles to achieve water and gas seals, respectively. Possible advantages of the {open_quotes}O{close_quotes} ring seal are: (1) simplification of component parts and elimination of van stone corrosion; (2) simplification of maintenance; (3) lower costs of initial erection; (4) increased strength. This test supplements Test Project No. 27 (a preliminary thermal cycling test) in applying the {open_quotes}O{close_quotes} ring seal assembly to actual pile operating conditions.

  9. Modeling and optimization of operating parameters for a test-cell option of the Fusion Power Demonstration-II tandem mirror design

    International Nuclear Information System (INIS)

    Haney, S.W.; Fenstermacher, M.E.

    1985-01-01

    Models of tandem mirror devices operated with a test-cell insert have been used to calculate operating parameters for FPD-II+T, an upgrade of the Fusion Power Demonstration-II device. Two test-cell configurations were considered, one accommodating two 1.5 m blanket test modules and the other having four. To minimize the cost of the upgrade, FPD-II+T utilizes the same coil arrangement and machine dimensions outside of the test cell as FPD-II, and the requirements on the end cell systems have been held near or below those for FPD-II. The maximum achievable test cell wall loading found for the short test-cell was 3.5 MW/m 2 while 6.0 MW/m 2 was obtainable in the long test-cell configuration. The most severe limitation on the achievable wall loading is the upper limit on test-cell beta set by MHD stability calculations. Modification of the shape of the magnetic field in the test-cell by improving the magnet design could raise this beta limit and lead to improved test-cell performance

  10. Spectrochemical study the effect of high energetic ionization radiation on Ru(III, Pd(II and Hg(II complexes

    Directory of Open Access Journals (Sweden)

    Samar A. Aly

    2017-04-01

    Thermal studies of these chelates before and after γ-irradiation stable that the complexes of Ru(III and Pd (II after γ-irradiation are more thermal show than Hg(II complexes before and after γ-irradiation.

  11. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    Energy Technology Data Exchange (ETDEWEB)

    Schaeck, S.; Stoermer, A.O. [BMW Group, 80788 Muenchen (Germany); Albers, J. [Johnson Controls Power Solutions EMEA, 30419 Hannover (Germany); Weirather-Koestner, D. [ZSW Ulm, 89081 Ulm (Germany); Kabza, H. [Universitaet Ulm, Institut fuer Energiewandlung und -speicherung, 89081 Ulm (Germany)

    2011-02-01

    In the first part of this work selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already. (author)

  12. Foreign Language Optical Character Recognition, Phase II: Arabic and Persian Training and Test Data Sets

    National Research Council Canada - National Science Library

    Davidson, Robert

    1997-01-01

    .... Each data set is divided into a training set, which is made available to developers, and a carefully matched equal-sized set of closely analogous samples, which is reserved for testing of the developers' products...

  13. Innovative Solid State Lighting Replacements for Industrial and Test Facility Locations, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed effort will develop a solid-state LED replacement lamp for rocket engine test stand lighting and more general hazardous-location lighting. The LED...

  14. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    Science.gov (United States)

    Schaeck, S.; Stoermer, A. O.; Albers, J.; Weirather-Koestner, D.; Kabza, H.

    In the first part of this work [1] selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. [1,6]. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already.

  15. Phase II test plan for the evaluation of the performance of container filling systems

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    The PHMC will provide tank wastes for final treatment by BNFL from Hanford's waste tanks. Concerns about the ability for ''grab'' sampling to provide large volumes of representative waste samples has led to the development of a nested, fixed-depth sampling system. Preferred concepts for filling sample containers that meet RCRA organic sample criteria were identified by a PHMC Decision Board. These systems will replace the needle based sampling ''T'' that is currently on the sampling system. This test plan document identifies cold tests with simulants that will demonstrate the preferred bottle filling concepts abilities to provide representative waste samples and will meet RCRA criteria. Additional tests are identified that evaluate the potential for cross-contamination between samples and the ability for the system to decontaminate surfaces which have contacted tank wastes. These tests will be performed with kaolidwater and sand/water slurry simulants in the test rig that was used by AEAT to complete Phase 1 tests in FY 1999

  16. Evaluation report on CCTF Core-II reflood test C2-16 (Run 76)

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Akimoto, Hajime; Okubo, Tsutomu; Hojo, Tsuneyuki; Murao, Yoshio; Sugimoto, Jun.

    1987-03-01

    This report presents the result of the upper plenum injection (UPI) test C2-16 (Run 76), which was conducted on October 23, 1984, with the Cylindrical Core Test Facility (CCTF) at Japan Atomic Energy Research Institute (JAERI). The CCTF is a 1/21.4 scale model of a 1,100 MWe PWR with four loop active components to provide information on the system and core thermo-hydrodynamics during reflood. The objectives of the test are to investigate the reflood phenomena with single failure UPI condition and to investigate the effect of the asymmetry of UPI on the reflood phenomena. The test was performed with an asymmetric UPI condition at the injection rate simulating single failure of LPCI pumps. It was observed that, (1) a UPI test simulating no LPCI pump failure gave the slightly lower peak clad temperature than a UPI test simulating single LPCI pump failure, indicating that single LPCI pump failure assumption is conserrative for UPI condition, and (2) an asymmetric UPI lead to a higher core water accumulation and then a higher heat transfer coefficient, resultantly a lower peak clad temperature than a symmetric UPI, indicating that asymmetric UPI does not lead to a poorer core cooling than symmetric UPI. (author)

  17. Wireless Roadside Inspection Phase II Tennessee Commercial Mobile Radio Services Pilot Test Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Franzese, Oscar [ORNL; Lascurain, Mary Beth [ORNL; Capps, Gary J [ORNL; Siekmann, Adam [ORNL

    2011-05-01

    The Federal Motor Carrier Safety Administration (FMCSA) Wireless Roadside Inspection (WRI) Program is researching the feasibility and value of electronically assessing truck and bus driver and vehicle safety at least 25 times more often than is possible using only roadside physical inspections. The WRI program is evaluating the potential benefits to both the motor carrier industry and to government. These potential benefits include reduction in accidents, fatalities and injuries on our highways and keeping safe and legal drivers and vehicles moving on the highways. WRI Pilot tests were conducted to prototype, test and demonstrate the feasibility and benefits of electronically collecting safety data message sets from in-service commercial vehicles and performing wireless roadside inspections using three different communication methods. This report summarizes the design, conduct and results of the Tennessee CMRS WRI Pilot Test. The purpose of this Pilot test was to demonstrate the implementation of commercial mobile radio services to electronically request and collect safety data message sets from a limited number of commercial vehicles operating in Tennessee. The results of this test have been used in conjunction with the results of the complimentary pilot tests to support an overall assessment of the feasibility and benefits of WRI in enhancing motor carrier safety (reduction in accidents) due to increased compliance (change in motor carrier and driver behavior) caused by conducting frequent safety inspections electronically, at highway speeds, without delay or need to divert into a weigh station

  18. Subsonic Ultra Green Aircraft Research: Phase II- Volume III-Truss Braced Wing Aeroelastic Test Report

    Science.gov (United States)

    Bradley, Marty K.; Allen, Timothy J.; Droney, Christopher

    2014-01-01

    This Test Report summarizes the Truss Braced Wing (TBW) Aeroelastic Test (Task 3.1) work accomplished by the Boeing Subsonic Ultra Green Aircraft Research (SUGAR) team, which includes the time period of February 2012 through June 2014. The team consisted of Boeing Research and Technology, Boeing Commercial Airplanes, Virginia Tech, and NextGen Aeronautics. The model was fabricated by NextGen Aeronautics and designed to meet dynamically scaled requirements from the sized full scale TBW FEM. The test of the dynamically scaled SUGAR TBW half model was broken up into open loop testing in December 2013 and closed loop testing from January 2014 to April 2014. Results showed the flutter mechanism to primarily be a coalescence of 2nd bending mode and 1st torsion mode around 10 Hz, as predicted by analysis. Results also showed significant change in flutter speed as angle of attack was varied. This nonlinear behavior can be explained by including preload and large displacement changes to the structural stiffness and mass matrices in the flutter analysis. Control laws derived from both test system ID and FEM19 state space models were successful in suppressing flutter. The control laws were robust and suppressed flutter for a variety of Mach, dynamic pressures, and angle of attacks investigated.

  19. Experimental study of the transition from forced to natural circulation in EBR-II at low power and flow

    International Nuclear Information System (INIS)

    Gillette, J.L.; Singer, R.M.; Tokar, J.V.; Sullivan, J.E.

    1979-01-01

    A series of tests have been conducted in EBR-II which studied the dynamics of the transition from forced to natural circulation flow in a liquid-metal-cooled fast breeder reactor (LMFBR). Each test was initiated by abruptly tripping an electromagnetic pump which supplies 5 to 6% of the normal full operational primary flow rate. The ensuing flow coast-down reached a minimum value after which the flow increased as natural circulation was established. The effects of secondary system flow through the intermediate heat exchanger and reactor decay power level on the minimum in-core flow rates and maximum in-core temperatures were examined

  20. Evaluation report on CCTF Core-II reflood test C2-1 (Run 55)

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Sugimoto, Jun; Akimoto, Hajime; Okubo, Tsutomu; Murao, Yoshio

    1991-10-01

    A high pressure test (0.42 MPa) on the reflood phenomena was performed with the CCTF. The result of the test was compared with the experimental result of the base case test (0.2 MPa). (1) The overall flow characteristics in the high pressure test were qualitatively similar to that of the base case test. Any qualitatively different phenomena were not recognized during reflood phase. This indicates that it is reasonable to utilize the physical reflood model developed from the result of the base case test to the high pressure condition at least up to 0.42 MPa for prediction of reflood behavior of PWRs. (2) On the other hand, following quantitative influence of high pressure on reflood phenomena was observed. The core cooling was better, and the mass flow rate of the steam generated in the core was larger. However, the steam velocity was smaller due to higher density of the steam. Therefore, the steam discharge through loops was easier and hence the so-called steam binding effect was weaker. And, the water accumulation rate in the core was larger. Consequently the core flooding mass flow rate was larger. Since the core cooling was better, the maximum core temperature was lower and the last quenching was earlier. This result was the same as that previously observed in CCTF tests in the scope of the pressure upto 0.3 MPa. (3) The higher pressure leads to the better core cooling, and hence the safety margin increases with the increase in the pressure. (author)

  1. Guidelines for uncertainty analysis developed for the participants in the BIOMOVS II study

    International Nuclear Information System (INIS)

    Baeverstam, U.; Davis, P.; Garcia-Olivares, A.; Henrich, E.; Koch, J.

    1993-07-01

    This report has been produced to provide guidelines for uncertainty analysis for use by participants in the BIOMOVS II study. It is hoped that others with an interest in modelling contamination in the biosphere will also find it useful. The report has been prepared by members of the Uncertainty and Validation Working Group and has been reviewed by other BIOMOVS II participants. The opinions expressed are those of the authors and should not be taken to represent the views of the BIOMOVS II sponsors or other BIOMOVS Il participating organisations

  2. Guidelines for uncertainty analysis developed for the participants in the BIOMOVS II study

    Energy Technology Data Exchange (ETDEWEB)

    Baeverstam, U; Davis, P; Garcia-Olivares, A; Henrich, E; Koch, J

    1993-07-01

    This report has been produced to provide guidelines for uncertainty analysis for use by participants in the BIOMOVS II study. It is hoped that others with an interest in modelling contamination in the biosphere will also find it useful. The report has been prepared by members of the Uncertainty and Validation Working Group and has been reviewed by other BIOMOVS II participants. The opinions expressed are those of the authors and should not be taken to represent the views of the BIOMOVS II sponsors or other BIOMOVS Il participating organisations.

  3. [Study on seed testing for Salvia miltiorrhiza].

    Science.gov (United States)

    Dan, Hong-mei; Qi, Jian-jun; Zhou, Li-li; Li, Xian-en

    2008-09-01

    To establish a seed testing methods for Salvia miltiorrhiza. Referring to the International Seed Testing Rules made by ISTA and the Seed Testing for Crops (GB/T3543. 1-1995) issued by China. The seeds are selected by winnowing; the seed purity is about 50%-60%; 100 grain weight is used to determine the quality of the seed; the seed moisture content is determined by air drying, the drying hour is 3 h. Seed viability is tested by TFC method.

  4. Mercury Phase II Study - Mercury Behavior in Salt Processing Flowsheet

    International Nuclear Information System (INIS)

    Jain, V.; Shah, H.; Wilmarth, W. R.

    2016-01-01

    Mercury (Hg) in the Savannah River Site Liquid Waste System (LWS) originated from decades of canyon processing where it was used as a catalyst for dissolving the aluminum cladding of reactor fuel. Approximately 60 metric tons of mercury is currently present throughout the LWS. Mercury has long been a consideration in the LWS, from both hazard and processing perspectives. In February 2015, a Mercury Program Team was established at the request of the Department of Energy to develop a comprehensive action plan for long-term management and removal of mercury. Evaluation was focused in two Phases. Phase I activities assessed the Liquid Waste inventory and chemical processing behavior using a system-by-system review methodology, and determined the speciation of the different mercury forms (Hg+, Hg++, elemental Hg, organomercury, and soluble versus insoluble mercury) within the LWS. Phase II activities are building on the Phase I activities, and results of the LWS flowsheet evaluations will be summarized in three reports: Mercury Behavior in the Salt Processing Flowsheet (i.e. this report); Mercury Behavior in the Defense Waste Processing Facility (DWPF) Flowsheet; and Mercury behavior in the Tank Farm Flowsheet (Evaporator Operations). The evaluation of the mercury behavior in the salt processing flowsheet indicates, inter alia, the following: (1) In the assembled Salt Batches 7, 8 and 9 in Tank 21, the total mercury is mostly soluble with methylmercury (MHg) contributing over 50% of the total mercury. Based on the analyses of samples from 2H Evaporator feed and drop tanks (Tanks 38/43), the source of MHg in Salt Batches 7, 8 and 9 can be attributed to the 2H evaporator concentrate used in assembling the salt batches. The 2H Evaporator is used to evaporate DWPF recycle water. (2) Comparison of data between Tank 21/49, Salt Solution Feed Tank (SSFT), Decontaminated Salt Solution Hold Tank (DSSHT), and Tank 50 samples suggests that the total mercury as well as speciated

  5. Secondary Electron Yield Measurements and Groove Chambers Tests in the PEP-II Beam Line Straights Sections

    International Nuclear Information System (INIS)

    Pivi, M

    2008-01-01

    Beam instability caused by the electron cloud has been observed in positron and proton storage rings and it is expected to be a limiting factor in the performance of the positron Damping Ring (DR) of future Linear Colliders such as ILC and CLIC [1, 2]. In the Positron Low Energy Ring (LER) of the PEP-II accelerator, we have installed vacuum chambers with rectangular grooves in a straight magnetic-free section to test this promising possible electron cloud mitigation technique. We have also installed a special chamber to monitor the secondary electron yield of TiN and TiZrV (NEG) coating, Copper, Stainless Steel and Aluminum under the effect of electron and photon conditioning in situ in the beam line. In this paper, we describe the ongoing R and D effort to mitigate the electron cloud effect for the ILC damping ring, the latest results on in situ secondary electron yield conditioning and recent update on the groove tests in PEP-II

  6. ynthesis, theoretical study on Zinc (II and Ni(II complexes of 5-methoxyisatin 3-[N-(4-chlorophenyl thiosemicarbazone

    Directory of Open Access Journals (Sweden)

    Fatma Kandemirli

    2012-03-01

    Full Text Available Zinc(II and nickel(II-complexes of 5-methoxyisatin 3-[N-(4-chlorophenyl thiosemicarbazone] (H2MICP were synthesized and characterized by infrared, ultraviolet and 1H-NMR spectroscopies as well as elemental analysis. Model of H2MICP and its zinc(II and nickel(II-complexes were optimized with B3LYP method using 6-31G(d,p, 6-311G(d,p, 6-311++G(d,p, 6-311++G(2d,2p basis sets. The calculated 1H-NMR, UV and IR spectra data were compared with experimental results. In addition to the Natural Bond Orbital (NBO analysis of H2MICP and its Zinc(II and Nickel(II complexes, Fukui functions of H2MICP were also reported.

  7. Hanford Immobilized LAW Product Acceptance: Tanks Focus Area Testing Data Package II

    International Nuclear Information System (INIS)

    Schulz, Rebecca L.; Lorier, Troy H.; Peeler, David K.; Brown, Kevin G.; Reamer, Irene A.; Vienna, John D.; Jiricka, Antonin; Jorgensen, Benaiah M.; Smith, Donald E.

    2001-01-01

    This report is a continuation of the Hanford Immobilized Low Activity Waste (LAW) Product Acceptance (HLP): Initial Tanks Focus Area Testing Data Package (Vienna (and others) 2000). In addition to new 5000-h product consistency test (PCT), vapor hydration test (VHT), and alteration products data, some previously reported data together with relevant background information are included for an easily accessible source of reference when comparing the response of the various glasses to different test conditions. A matrix of 55 glasses was developed and tested to identify the impact of glass composition on long-term corrosion behavior and to develop an acceptable composition region for Hanford LAW glasses. Of the 55 glasses, 45 were designed to systematically vary the glass composition, and 10 were selected because large and growing databases on their corrosion characteristics had accumulated. The targeted and measured compositions of these glasses are found in the Appendix A. All glasses were fabricated according to standard procedures and heat treated to simulate the slow cooling that will occur in a portion of the waste glass after vitrification in the planned treatment facility at Hanford

  8. The Effectiveness Test of Oil Phase Ointment Containing Snakehead Fish (Channa striata Extract on Open Stage II Acute Wounded Wistar Strain Male Rats

    Directory of Open Access Journals (Sweden)

    Fransisca Daisa

    2017-08-01

    Full Text Available The snakehead (Channa striata contained fatty acids omega-3 and omega-6 are useful as nutrients in accelerating the wound healing process. This study aims to determine the effectiveness of the oil phase extract ointment snakehead in the healing of acute wounds open stage II. Testing the effectiveness of wound healing using 6 groups: normal, gel bioplacenton (positive control, ointment base (negative control, ointments snakehead extract oil phase concentration of 10; 20 and 40% of the 4 rats with acute wounds open stage II and observation until day 16 injury. The area of the wound was measured with the image J program Macbiophotonic, calculated% healing power, and AUC values. A statistical test to the total AUC values per rat with SPSS for Windows 22.0 program using One Way ANOVA and Post-hoc LSD test. The results showed a significant difference in the negative group with ointment concentration of 20% (p <0.05. The treatment group phase ointment fish oil extract is effective for wound healing is best to have a concentration of 20% for percentage of wound healing power of 97.157% and the average AUC value of 865.683% of the day.

  9. Iron(II) porphyrins induced conversion of nitrite into nitric oxide: A computational study.

    Science.gov (United States)

    Zhang, Ting Ting; Liu, Yong Dong; Zhong, Ru Gang

    2015-09-01

    Nitrite reduction to nitric oxide by heme proteins was reported as a protective mechanism to hypoxic injury in mammalian physiology. In this study, the pathways of nitrite reduction to nitric oxide mediated by iron(II) porphyrin (P) complexes, which were generally recognized as models for heme proteins, were investigated by using density functional theory (DFT). In view of two type isomers of combination of nitrite and Fe(II)(P), N-nitro- and O-nitrito-Fe(II)-porphyrin complexes, and two binding sites of proton to the different O atoms of nitrite moiety, four main pathways for the conversion of nitrite into nitric oxide mediated by iron(II) porphyrins were proposed. The results indicate that the pathway of N-bound Fe(II)(P)(NO2) isomer into Fe(III)(P)(NO) and water is similar to that of O-bound isomer into nitric oxide and Fe(III)(P)(OH) in both thermodynamical and dynamical aspects. Based on the initial computational studies of five-coordinate nitrite complexes, the conversion of nitrite into NO mediated by Fe(II)(P)(L) complexes with 14 kinds of proximal ligands was also investigated. Generally, the same conclusion that the pathways of N-bound isomers are similar to those of O-bound isomer was obtained for iron(II) porphyrin with ligands. Different effects of ligands on the reduction reactions were also found. It is notable that the negative proximal ligands can improve reactive abilities of N-nitro-iron(II) porphyrins in the conversion of nitrite into nitric oxide compared to neutral ligands. The findings will be helpful to expand our understanding of the mechanism of nitrite reduction to nitric oxide by iron(II) porphyrins. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Testing the applicability of the k 0-NAA method at the MINT's TRIGA MARK II reactor

    International Nuclear Information System (INIS)

    Siong, Wee Boon; Dung, Ho Manh; Wood, Ab. Khalik; Salim, Nazaratul Ashifa Abd.; Elias, Md. Suhaimi

    2006-01-01

    The Analytical Chemistry Laboratory at MINT is using the NAA technique since 1980s and is the only laboratory in Malaysia equipped with a research reactor, namely the TRIGA MARK II. Throughout the years the development of NAA technique has been very encouraging and was made applicable to a wide range of samples. At present, the k 0 method has become the preferred standardization method of NAA (k 0 -NAA) due to its multi-elemental analysis capability without using standards. Additionally, the k 0 method describes NAA in physically and mathematically understandable definitions and is very suitable for computer evaluation. Eventually, the k 0 -NAA method has been adopted by MINT in 2003, in collaboration with the Nuclear Research Institute (NRI), Vietnam. The reactor neutron parameters (α and f) for the pneumatic transfer system and for the rotary rack at various locations, as well as the detector efficiencies were determined. After calibration of the reactor and the detectors, the implemented k 0 method was validated by analyzing some certified reference materials (including IAEA Soil 7, NIST 1633a, NIST 1632c, NIST 1646a and IAEA 140/TM). The analysis results of the CRMs showed an average u score well below the threshold value of 2 with a precision of better than ±10% for most of the elemental concentrations obtained, validating herewith the introduction of the k 0 -NAA method at the MINT

  11. Testing the applicability of the k0-NAA method at the MINT's TRIGA MARK II reactor

    Science.gov (United States)

    Siong, Wee Boon; Dung, Ho Manh; Wood, Ab. Khalik; Salim, Nazaratul Ashifa Abd.; Elias, Md. Suhaimi

    2006-08-01

    The Analytical Chemistry Laboratory at MINT is using the NAA technique since 1980s and is the only laboratory in Malaysia equipped with a research reactor, namely the TRIGA MARK II. Throughout the years the development of NAA technique has been very encouraging and was made applicable to a wide range of samples. At present, the k0 method has become the preferred standardization method of NAA ( k0-NAA) due to its multi-elemental analysis capability without using standards. Additionally, the k0 method describes NAA in physically and mathematically understandable definitions and is very suitable for computer evaluation. Eventually, the k0-NAA method has been adopted by MINT in 2003, in collaboration with the Nuclear Research Institute (NRI), Vietnam. The reactor neutron parameters ( α and f) for the pneumatic transfer system and for the rotary rack at various locations, as well as the detector efficiencies were determined. After calibration of the reactor and the detectors, the implemented k0 method was validated by analyzing some certified reference materials (including IAEA Soil 7, NIST 1633a, NIST 1632c, NIST 1646a and IAEA 140/TM). The analysis results of the CRMs showed an average u score well below the threshold value of 2 with a precision of better than ±10% for most of the elemental concentrations obtained, validating herewith the introduction of the k0-NAA method at the MINT.

  12. Enertech 2-kW high-reliability wind system. Phase II. Fabrication and testing

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, J A; Johnson, B A

    1981-06-01

    A high-reliability wind machine rated for 2 kW in a 9 m/s wind has been developed. Activities are summarized that are centered on the fabrication and testing of prototypes of the wind machine. The test results verified that the wind machine met the power output specification and that the variable-pitch rotor effectively controlled the rotor speed for wind speeds up to 50 mph. Three prototypes of the wind machine were shipped to the Rocky Flats test center in September through November of 1979. Work was also performed to reduce the start-up wind speed. The start-up wind speed to the Enertech facility has been reduced to 4.5 m/s.

  13. Near-term electric test vehicle ETV-2. Phase II. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1981-04-01

    A unique battery-powered passenger vehicle has been developed that provides a significant improvement over conventional electric vehicle performance, particularly during stop-and-go driving. The vehicle is unique in two major respects: (1) the power system incorporates a flywheel that stores energy during regenerative braking and makes possible the acceleration capability needed to keep up with traffic without reducing range to unacceptable values; and (2) lightweight plastic materials are used for the vehicle unibody to minimize weight and increase range. These features were analyzed and demonstrated in an electric test vehicle, ETV-2. Characteristics of this vehicle are summarized. Information is presented on: vehicle design, fabrication, safety testing, and performance testing; power system design and operation; flywheel; battery pack performance; and controls and electronic equipment. (LCL)

  14. Evaluation report on CCTF core-II reflood test C2 - 18 (Run 78)

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Akimoto, Hajime; Okubo, Tsutomu; Murao, Yoshio; Sugimoto, Jun; Hojo, Tsuneyuki.

    1987-03-01

    This report presents the result of the upper plenum injection (UPI) test C2 - 18 (Run 78), which was conducted on November 13, 1984 with the Cylindrical Core Test Facility (CCTF) at Japan Atomic Energy Research Institute (JAERI). The CCTF is a 1/21.4 scale model of a 1,100 MWe PWR with four loop active components to provide information on the system and core thermo-hydrodynamics during reflood phase. The objectives of the test are to investigate the refill behavior with UPI condition and to investigate the reflood behavior with UPI Best-Estimate (BE) condition. The test was performed to simulate refill/reflood behavior with UPI and BE conditions (However, the LPCI flow rate was determined based on single failure of LPCI pumps.). The result of the test showed the followings. (1) Little special phenomena were recognized under UPI and BE conditions in comparison with those under UPI and Evaluation-Model (EM) conditions, although certain special phenoma (i.e. significant fluid oscillation) were recognized under Cold-Leg-Injection (CLI) and BE conditions in comparison with those under CLI and EM conditions. (2) Water inventory in lower plenum increased smoothly due to water injected into both upper plenum and cold leg during refill phase, similarly to that in refill-simulation test with CLI condition. Small difference in refill behavior with UPI condition is the existing of steam condensation in upper plenum, resulting in lower steam binding and higher core cooling during early reflood phase. This indicates the conservatism of UPI against CLI during early reflood phase. (3) The good core-cooling capability was confirmed under UPI and BE conditions. (author)

  15. Phase II Transport Model of Corrective Action Unit 98: Frenchman Flat, Nevada Test Site, Nye County, Nevada, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Gregg Ruskuaff

    2010-01-01

    This document, the Phase II Frenchman Flat transport report, presents the results of radionuclide transport simulations that incorporate groundwater radionuclide transport model statistical and structural uncertainty, and lead to forecasts of the contaminant boundary (CB) for a set of representative models from an ensemble of possible models. This work, as described in the Federal Facility Agreement and Consent Order (FFACO) Underground Test Area (UGTA) strategy (FFACO, 1996; amended 2010), forms an essential part of the technical basis for subsequent negotiation of the compliance boundary of the Frenchman Flat corrective action unit (CAU) by Nevada Division of Environmental Protection (NDEP) and National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Underground nuclear testing via deep vertical shafts was conducted at the Nevada Test Site (NTS) from 1951 until 1992. The Frenchman Flat area, the subject of this report, was used for seven years, with 10 underground nuclear tests being conducted. The U.S. Department of Energy (DOE), NNSA/NSO initiated the UGTA Project to assess and evaluate the effects of underground nuclear tests on groundwater at the NTS and vicinity through the FFACO (1996, amended 2010). The processes that will be used to complete UGTA corrective actions are described in the “Corrective Action Strategy” in the FFACO Appendix VI, Revision No. 2 (February 20, 2008).

  16. NMR study of the possible interaction in solution of angiotensin II with a peptide encoded by angiotensin II complementary RNA

    International Nuclear Information System (INIS)

    Eaton, H.L.; Fesik, S.W.; Austin, R.E.; Martin, S.F.

    1989-01-01

    The potential binding of angiotensin II (Asp-Arg-Val-Tyr-Ile-His-Pro-Phe) (AII) to a peptide encoded by its complementary RNA (Lys-Gly-Val-Asp-Val-Try-Ala-Val) (IIA) has been studied by monitoring the 1 H NMR spectrum of IIA in aqueous phosphate or Tris·HCl buffer ( 2 H 2 O) as it is titrated with AII. For molar ratios of AII/IIA ranging from 0.2 to 1.8, the NMR spectra are unchanged as compared to the spectra of the isolated peptides. Based on these findings, the K d for the putative biomolecular complex of the two peptides under these conditions is calculated to be >10 -4 M. This result does not support the suggestion of Elton et al. that AII and IIA engage in high-affinity binding (K d ∼ 5 x 10 -8 M) with each other

  17. Phase II study on stereotactic body radiotherapy of colorectal metastases

    DEFF Research Database (Denmark)

    Høyer, Morten; Roed, Henrik; Traberg Hansen, Anders

    2006-01-01

    Surgical resection provides long term survival in approximately 30% of patients with colorectal carcinoma (CRC) liver metastases. However, only a limited number of patients with CRC-metastases are amendable for surgery. We have tested the effect of stereotactic body radiotherapy (SBRT) in the tre......Surgical resection provides long term survival in approximately 30% of patients with colorectal carcinoma (CRC) liver metastases. However, only a limited number of patients with CRC-metastases are amendable for surgery. We have tested the effect of stereotactic body radiotherapy (SBRT......) in the treatment of inoperable patients with CRC-metastases. Sixty-four patients with a total number of 141 CRC-metastases in the liver (n = 44), lung (n = 12), lymph nodes (n = 3), suprarenal gland (n = 1) or two organs (n = 4) were treated with SBRT with a central dose of 15 Gy x 3 within 5-8 days. Median follow...... due to hepatic failure, one patient was operated for a colonic perforation and two patients were conservatively treated for duodenal ulcerations. Beside these, only moderate toxicities such as nausea, diarrhoea and skin reactions were observed. SBRT in patients with inoperable CRC-metastases resulted...

  18. Considerations on photochemical genotoxicity. II: Report of the 2009 International Workshop on Genotoxicity Testing Working Group

    NARCIS (Netherlands)

    Lynch, A.M.; Guzzie, P.J.; Bauer, D.; Gocke, E.; Itoh, S.; Jacobs, A.; Krul, C.A.M.; Schepky, A.; Tanaka, N.; Kasper, P.

    2011-01-01

    A workshop to reappraise the previous IWGT recommendations for photogenotoxicity testing [E. Gocke, L. Muller, P.J. Guzzie, S. Brendler-Schwaab, S. Bulera, C.F. Chignell, L.M. Henderson, A. Jacobs, H. Murli, R.D. Snyder, N. Tanaka, Considerations on photochemical genotoxicity: report of the

  19. Lithium-ion batteries for hearing aid applications. II. Pulse discharge and safety tests

    Science.gov (United States)

    Passerini, S.; Coustier, F.; Owens, B. B.

    Rechargeable lithium-ion batteries were designed to meet the power requirements of hearing aid devices (HADs). The batteries were designed in a 312-button cell size, compatible with existing hearing aids. The batteries were tested to evaluate the design and the electrochemical performance, as they relate to a typical hearing aid application. The present report covers the pulse capabilities, cycle life and preliminary safety tests. The results are compared with other battery chemistries: secondary lithium-alloy and nickel-metal hydride batteries and primary Zn-air batteries. The cell AC impedance was stable over the frequency range between 1 and 50 kHz, ranging between 5 Ω at the higher frequency and 12 Ω at the lower extreme. Pulse tests were consistent with these values, as the cells were capable of providing a series of 100 mA pulses of 10-s duration. The safety tests suggest that the design is intrinsically safe with respect to the most common types of abuse conditions.

  20. Immunochemical studies of Lolium perenne (rye grass) pollen allergens, Lol p I, II, and III.

    Science.gov (United States)

    Ansari, A A; Kihara, T K; Marsh, D G

    1987-12-15

    It was reported earlier that human immune responses to three perennial rye grass (Lolium perenne) pollen allergens, Lol p I, II, and III, are associated with histocompatibility leukocyte antigen (HLA)-DR3. Rye-allergic people are often concordantly sensitive to all three of these allergens. Since earlier studies suggested that these antigens are non-cross-reactive, their immunologic relatedness by double antibody radioimmunoassay (DARIA) was studied in order to understand further the immunochemical basis for the concordant recognition of the three allergens. Direct binding DARIA studies were performed with human sera from 189 allergic subjects. Inhibition DARIA studies were carried out with 17 human sera from grass-allergic patients who were on grass immunotherapy, one goat anti-serum, and six rabbit antisera. None of the sera detected any significant degree of two-way cross-reactivity between Lol p I and II, or between Lol p I and III. However, the degree of two-way cross-reactivity between Lol p II and III exhibited by individual human and animal antisera varied between undetectable and 100%. In general, the degree of cross-reactivity between Lol p II and III was higher among human sera than among animal sera. Taken together with earlier findings that antibody responses to Lol p I, II and III are associated with HLA-HDR3, and that most Lol p II and III responders are also Lol p I responders, but not vice versa, our present results suggest the following: the HLA-DR3-encoded Ia molecule recognizes a similar immunodominant Ia recognition site (agretope) shared between Lol p I and Lol p II and/or III; in addition, Lol p I appears to contain unique Ia recognition site(s) not present in Lol p II and III. However, further epitope analyses are required to investigate these possibilities.