WorldWideScience

Sample records for test strips options

  1. Thermal test options

    International Nuclear Information System (INIS)

    Koski, J.A.; Keltner, N.R.; Sobolik, K.B.

    1993-02-01

    Shipping containers for radioactive materials must be qualified to meet a thermal accident environment specified in regulations, such at Title 10, Code of Federal Regulations, Part 71. Aimed primarily at the shipping container design, this report discusses the thermal testing options available for meeting the regulatory requirements, and states the advantages and disadvantages of each approach. The principal options considered are testing with radiant heat, furnaces, and open pool fires. The report also identifies some of the facilities available and current contacts. Finally, the report makes some recommendations on the appropriate use of these different testing methods

  2. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  3. Nanoscale Test Strips for Multiplexed Blood Analysis

    Science.gov (United States)

    Chan, Eugene

    2015-01-01

    A critical component of the DNA Medicine Institute's Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) sensor are nanoscale test strips, or nanostrips, that enable multiplexed blood analysis. Nanostrips are conceptually similar to the standard urinalysis test strip, but the strips are shrunk down a billionfold to the microscale. Each nanostrip can have several sensor pads that fluoresce in response to different targets in a sample. The strips carry identification tags that permit differentiation of a specific panel from hundreds of other nanostrip panels during a single measurement session. In Phase I of the project, the company fabricated, tested, and demonstrated functional parathyroid hormone and vitamin D nanostrips for bone metabolism, and thrombin aptamer and immunoglobulin G antibody nanostrips. In Phase II, numerous nanostrips were developed to address key space flight-based medical needs: assessment of bone metabolism, immune response, cardiac status, liver metabolism, and lipid profiles. This unique approach holds genuine promise for space-based portable biodiagnostics and for point-of-care (POC) health monitoring and diagnostics here on Earth.

  4. Strip reduction testing of lubricants developed during ENFORM project

    DEFF Research Database (Denmark)

    Gazvoda, S.; Andreasen, Jan Lasson; Olsson, David Dam

    Strip reduction testing of lubricants developed during ENFORM project. Experiments were conducted with the strip reduction test [1] in order to classify experimental lubricants, developed during concerned project. One reference lubricant was used during testing....

  5. Strip specimen tests for pipeline materials and girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  6. Quality Tests of Double-Sided Silicon Strip Detectors

    CERN Document Server

    Cambon, T; CERN. Geneva; Fintz, P; Guillaume, G; Jundt, F; Kuhn, C; Lutz, Jean Robert; Pagès, P; Pozdniakov, S; Rami, F; Sparavec, K; Dulinski, W; Arnold, L

    1997-01-01

    The quality of the SiO2 insulator (AC coupling between metal and implanted strips) of double-sided Silicon strip detectors has been studied by using a probe station. Some tests performed on 23 wafers are described and the results are discussed. Remark This note seems to cause problems with ghostview but it can be printed without any problem.

  7. Strip defect recognition in electrical tests of silicon microstrip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Valentan, Manfred, E-mail: valentan@mpp.mpg.de

    2017-02-11

    This contribution describes the measurement procedure and data analysis of AC-coupled double-sided silicon microstrip sensors with polysilicon resistor biasing. The most thorough test of a strip sensor is an electrical measurement of all strips of the sensor; the measured observables include e.g. the strip's current and the coupling capacitance. These measurements are performed to find defective strips, e.g. broken capacitors (pinholes) or implant shorts between two adjacent strips. When a strip has a defect, its observables will show a deviation from the “typical value”. To recognize and quantify certain defects, it is necessary to determine these typical values, i.e. the values the observables would have without the defect. As a novel approach, local least-median-of-squares linear fits are applied to determine these “would-be” values of the observables. A least-median-of-squares fit is robust against outliers, i.e. it ignores the observable values of defective strips. Knowing the typical values allows to recognize, distinguish and quantify a whole range of strip defects. This contribution explains how the various defects appear in the data and in which order the defects can be recognized. The method has been used to find strip defects on 30 double-sided trapezoidal microstrip sensors for the Belle II Silicon Vertex Detector, which have been measured at the Institute of High Energy Physics, Vienna (Austria).

  8. Continuous Strip Reduction Test Simulating Tribological Conditions in Ironing

    DEFF Research Database (Denmark)

    Üstünyagiz, Esmeray; Nielsen, Chris Valentin; Christiansen, Peter

    2017-01-01

    materials, surface roughnesses, normal pressure, sliding length, sliding speed, interface temperature and lubrication. This paper proposes a new Strip Reduction Test (SRT) for industrial ironing processes that is capable of replicating the highly severe tribological conditions that are experienced during...

  9. Nanoscale Test Strips for Multiplexed Blood Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of our nanoscale test strips, or nanostrips, is to provide rapid, low-cost, powerful multiplexed analyses in a diminutive form so that whole body health...

  10. Beam test of CSES silicon strip detector module

    Science.gov (United States)

    Zhang, Da-Li; Lu, Hong; Wang, Huan-Yu; Li, Xin-Qiao; Xu, Yan-Bing; An, Zheng-Hua; Yu, Xiao-xia; Wang, Hui; Shi, Feng; Wang, Ping; Zhao, Xiao-Yun

    2017-05-01

    The silicon-strip tracker of the China Seismo-Electromagnetic Satellite (CSES) consists of two double-sided silicon strip detectors (DSSDs) which provide incident particle tracking information. A low-noise analog ASIC VA140 was used in this study for DSSD signal readout. A beam test on the DSSD module was performed at the Beijing Test Beam Facility of the Beijing Electron Positron Collider (BEPC) using a 400-800 MeV/c proton beam. The pedestal analysis results, RMSE noise, gain correction, and intensity distribution of incident particles of the DSSD module are presented. Supported by the XXX Civil Space Programme

  11. Urine Test Strips to Exclude Cerebral Spinal Fluid Blood

    Directory of Open Access Journals (Sweden)

    Marshall, Robin A

    2011-02-01

    Full Text Available Introduction: Determining the presence or absence of red blood cells (RBC or their breakdown products in cerebrospinal fluid (CSF is essential for the evaluation of subarachnoid hemorrhage (SAH in headache patients. Current methodology for finding blood in the CSF is either spectrophotometric detection of pigment, which is time consuming and labor intensive, or visual assesment of samples for color change (xanthochromia, which is inaccurate. Bayer Multistix® urine test strips are designed to test urine for RBC by detecting the presence of hemoglobin. The aim of this pilot study was to evaluate the perfomance of urine reagent test strips for ruling out the presence of RBC in CSF.Methods: We compared color changes on Multistix® urine test strips to the standard of spectrophotometric absorbtion at 415nm and initial RBC counts in 138 visually clear CSF samples.Results: We performed Pearson Chi-Square and likelihood ratios on the results and found a correlation between a negative result on the urine test strip and less than 5 RBC per high power field and a spectrophotometric absorbance of less than 0.02% at 415nm in a CSF sample.Conclusion: These results warrant further investigation in the form of a prospective clinical validation as it may alter the emergency department evaluation for SAH. [West J Emerg Med. 2011;12(1:63-66.

  12. Beam tests of ATLAS SCT silicon strip detector modules

    Czech Academy of Sciences Publication Activity Database

    Campabadal, F.; Fleta, C.; Key, M.; Böhm, Jan; Mikeštíková, Marcela; Šťastný, Jan

    2005-01-01

    Roč. 538, - (2005), s. 384-407 ISSN 0168-9002 R&D Projects: GA MŠk(CZ) 1P04LA212 Institutional research plan: CEZ:AV0Z10100502 Keywords : ATLAS * silicon * micro-strip * beam * test Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.224, year: 2005

  13. Results of Laboratory Testing of Advanced Power Strips

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-08-01

    Presented at the ACEEE Summer Study on Energy Efficiency in Buildings on August 12-17, 2012, this presentation reports on laboratory tests of 20 currently available advanced power strip products, which reduce wasteful electricity use of miscellaneous electric loads in buildings.

  14. Strips of hourly power options. Approximate hedging using average-based forward contracts

    International Nuclear Information System (INIS)

    Lindell, Andreas; Raab, Mikael

    2009-01-01

    We study approximate hedging strategies for a contingent claim consisting of a strip of independent hourly power options. The payoff of the contingent claim is a sum of the contributing hourly payoffs. As there is no forward market for specific hours, the fundamental problem is to find a reasonable hedge using exchange-traded forward contracts, e.g. average-based monthly contracts. The main result is a simple dynamic hedging strategy that reduces a significant part of the variance. The idea is to decompose the contingent claim into mathematically tractable components and to use empirical estimations to derive hedging deltas. Two benefits of the method are that the technique easily extends to more complex power derivatives and that only a few parameters need to be estimated. The hedging strategy based on the decomposition technique is compared with dynamic delta hedging strategies based on local minimum variance hedging, using a correlated traded asset. (author)

  15. Comparison of blood glucose test strips in the detection of neonatal hypoglycaemia

    OpenAIRE

    Wilkins, B H; Kalra, D

    1982-01-01

    Blood glucose levels were estimated in 101 neonatal blood samples using three glucose test strip methods and the results compared with those from a laboratory. BM-test-glycemie 20-800 test strips and Reflotest-hypoglycemie test strips gave a rapid and reliable estimate of blood glucose level in the range 0-8 mmol/l (0-140 mg/100 ml). Dextrostix test strips tended to overestimate all blood glucose levels.

  16. Beam tests of ATLAS SCT silicon strip detector modules

    CERN Document Server

    Campabadal, F; Key, M; Lozano, M; Martínez, C; Pellegrini, G; Rafí, J M; Ullán, M; Johansen, L; Pommeresche, B; Stugu, B; Ciocio, A; Fadeev, V; Gilchriese, M G D; Haber, C; Siegrist, J; Spieler, H; Vu, C; Bell, P J; Charlton, D G; Dowell, John D; Gallop, B J; Homer, R J; Jovanovic, P; Mahout, G; McMahon, T J; Wilson, J A; Barr, A J; Carter, J R; Fromant, B P; Goodrick, M J; Hill, J C; Lester, C G; Palmer, M J; Parker, M A; Robinson, D; Sabetfakhri, A; Shaw, R J; Anghinolfi, F; Chesi, Enrico Guido; Chouridou, S; Fortin, R; Grosse-Knetter, J; Gruwé, M; Ferrari, P; Jarron, P; Kaplon, J; MacPherson, A; Niinikoski, T O; Pernegger, H; Roe, S; Rudge, A; Ruggiero, G; Wallny, R; Weilhammer, P; Bialas, W; Dabrowski, W; Grybos, P; Koperny, S; Blocki, J; Brückman, P; Gadomski, S; Godlewski, J; Górnicki, E; Malecki, P; Moszczynski, A; Stanecka, E; Stodulski, M; Szczygiel, R; Turala, M; Wolter, M; Ahmad, A; Benes, J; Carpentieri, C; Feld, L; Ketterer, C; Ludwig, J; Meinhardt, J; Runge, K; Mikulec, B; Mangin-Brinet, M; D'Onofrio, M; Donega, M; Moêd, S; Sfyrla, A; Ferrère, D; Clark, A G; Perrin, E; Weber, M; Bates, R L; Cheplakov, A P; Saxon, D H; O'Shea, V; Smith, K M; Iwata, Y; Ohsugi, T; Kohriki, T; Kondo, T; Terada, S; Ujiie, N; Ikegami, Y; Unno, Y; Takashima, R; Brodbeck, T; Chilingarov, A G; Hughes, G; Ratoff, P; Sloan, T; Allport, P P; Casse, G L; Greenall, A; Jackson, J N; Jones, T J; King, B T; Maxfield, S J; Smith, N A; Sutcliffe, P; Vossebeld, Joost Herman; Beck, G A; Carter, A A; Lloyd, S L; Martin, A J; Morris, J; Morin, J; Nagai, K; Pritchard, T W; Anderson, B E; Butterworth, J M; Fraser, T J; Jones, T W; Lane, J B; Postranecky, M; Warren, M R M; Cindro, V; Kramberger, G; Mandic, I; Mikuz, M; Duerdoth, I P; Freestone, J; Foster, J M; Ibbotson, M; Loebinger, F K; Pater, J; Snow, S W; Thompson, R J; Atkinson, T M; Bright, G; Kazi, S; Lindsay, S; Moorhead, G F; Taylor, G N; Bachindgagyan, G; Baranova, N; Karmanov, D; Merkine, M; Andricek, L; Bethke, Siegfried; Kudlaty, J; Lutz, Gerhard; Moser, H G; Nisius, R; Richter, R; Schieck, J; Cornelissen, T; Gorfine, G W; Hartjes, F G; Hessey, N P; de Jong, P; Muijs, A J M; Peeters, S J M; Tomeda, Y; Tanaka, R; Nakano, I; Dorholt, O; Danielsen, K M; Huse, T; Sandaker, H; Stapnes, S; Bargassa, Pedrame; Reichold, A; Huffman, T; Nickerson, R B; Weidberg, A; Doucas, G; Hawes, B; Lau, W; Howell, D; Kundu, N; Wastie, R; Böhm, J; Mikestikova, M; Stastny, J; Broklová, Z; Broz, J; Dolezal, Z; Kodys, P; Kubík, P; Reznicek, P; Vorobel, V; Wilhelm, I; Chren, D; Horazdovsky, T; Linhart, V; Pospísil, S; Sinor, M; Solar, M; Sopko, B; Stekl, I; Ardashev, E N; Golovnya, S N; Gorokhov, S A; Kholodenko, A G; Rudenko, R E; Ryadovikov, V N; Vorobev, A P; Adkin, P J; Apsimon, R J; Batchelor, L E; Bizzell, J P; Booker, P; Davis, V R; Easton, J M; Fowler, C; Gibson, M D; Haywood, S J; MacWaters, C; Matheson, J P; Matson, R M; McMahon, S J; Morris, F S; Morrissey, M; Murray, W J; Phillips, P W; Tyndel, M; Villani, E G; Dorfan, D E; Grillo, A A; Rosenbaum, F; Sadrozinski, H F W; Seiden, A; Spencer, E; Wilder, M; Booth, P; Buttar, C M; Dawson, I; Dervan, P; Grigson, C; Harper, R; Moraes, A; Peak, L S; Varvell, K E; Chu Ming Lee; Hou Li Shing; Lee Shih Chang; Teng Ping Kun; Wan Chang Chun; Hara, K; Kato, Y; Kuwano, T; Minagawa, M; Sengoku, H; Bingefors, N; Brenner, R; Ekelöf, T J C; Eklund, L; Bernabeu, J; Civera, J V; Costa, M J; Fuster, J; García, C; García, J E; González-Sevilla, S; Lacasta, C; Llosa, G; Martí i García, S; Modesto, P; Sánchez, J; Sospedra, L; Vos, M; Fasching, D; González, S; Jared, R C; Charles, E

    2005-01-01

    The design and technology of the silicon strip detector modules for the Semiconductor Tracker (SCT) of the ATLAS experiment have been finalised in the last several years. Integral to this process has been the measurement and verification of the tracking performance of the different module types in test beams at the CERN SPS and the KEK PS. Tests have been performed to explore the module performance under various operating conditions including detector bias voltage, magnetic field, incidence angle, and state of irradiation up to 3 multiplied by 1014 protons per square centimetre. A particular emphasis has been the understanding of the operational consequences of the binary readout scheme.

  17. Initial Beam Test of the Prototype Strip Line BPM

    International Nuclear Information System (INIS)

    Kwon, Hyeok Jung; Kim, Han Sung; Seol, Kyung Tae; Ryu, Jin Yeong; Jang, Ji Ho; Cho, Yong Sub

    2011-01-01

    A beam position monitor (BPM) was developed which would be used for the Proton Engineering Frontier Project (PEFP) beam line. It is a strip line BPM which is commonly used one for the proton beam. The BPM cross section was designed with the SUPERFISH code and the matching section to the feed through was designed by the MWS code. The design parameters of the BPM are shown in Table 1. The designed BPM was fabricated to verify the manufacturing process and check its electrical performance. After the low power test at the test stand, the BPM was installed at the 20-MeV proton accelerator beam line as shown in Fig. 1

  18. Test-beam evaluation of heavily irradiated silicon strip modules for ATLAS Phase-II Strip Tracker Upgrade

    CERN Document Server

    Blue, Andrew; The ATLAS collaboration

    2018-01-01

    The planned HL-LHC (High Luminosity LHC) is being designed to maximise the physics potential of the LHC with 10 years of operation at instantaneous luminosities of 7.5x1034cm−2s−1. A consequence of this increased luminosity is the expected radiation damage requiring the tracking detectors to withstand hadron equivalences to over 1x1015 1 MeV neutron equivalent per cm2 in the ATLAS Strips system. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics are glued on top of a silicon sensor to make a module. The radiation hard n-in-p micro-strip sensors used have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics. A series of tests were performed at the DESY-II and CERN SPS test beam facilities to investigate the detailed performance of a strip module with both 2.5cm and 5cm length strips before and after irradiation with 8x1014neqcm−2 protons and a total ionising dose of 37.2MRad. The DURA...

  19. Test strip at the Musters lake area, Chubut province (Argentina)

    International Nuclear Information System (INIS)

    Lopez, Luis E.

    1998-01-01

    A local test strip to determine both the system sensitivities and height attenuation coefficients was defined at the Musters Lake area, for its use in airborne spectrometric surveys in the South Patagonia region. The selected calibration range presents both low and uniform radioelement concentration. The mean spectrometer values obtained at ground level were 1.8 % K, 1.6 ppm eU and 7.3 ppm eTh while the variation coefficients were 7.5 %, 27.0 %, and 10.2 %, respectively. These values as well as range dimensions, moisture condition, easy access, easy navigation for aircraft, proximity to a fresh water body and with no flight restrictions are consistent with the international recommendations for setting up a test range. (author)

  20. Test strip at the Musters Lake area, Chubut province (Argentina)

    International Nuclear Information System (INIS)

    Lopez, Luis E.

    1998-01-01

    A local test strip to determine both the system sensitivities and height attenuation coefficients was defined at the Musters Lake area, for its use in airborne spectrometric surveys in the South Patagonia region. The selected calibration range presents both low and uniform radioelement concentrations. The mean spectrometer values obtained at ground level were 1.8 % K, 1.6 ppm eU and 7.3 ppm eTh while the variation coefficients were 7.5 %, 27.0 %, and 10.2 %, respectively. These values as well as range dimensions, moisture condition, easy access, easy navigation for aircraft, proximity to a fresh water body and with no flight restrictions are consistent with the international recommendations for setting up a test range. (author)

  1. Note: Simulation and test of a strip source electron gun.

    Science.gov (United States)

    Iqbal, Munawar; Islam, G U; Misbah, I; Iqbal, O; Zhou, Z

    2014-06-01

    We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm(2), respectively, that corresponds to power density of 11.5 kW/cm(2), at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive. Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.

  2. Biomechanical behaviour - Anisotropy of eye cornea through experimental strip tests

    Science.gov (United States)

    Arsalan Khan, Mohammad; Elsheikh, Ahmed; Khan, Iqtedar Ahmad

    2018-02-01

    With the advent of research it was identified that material properties are responsible for errors in tonometry pressure (referred to as Goldmann IOP or IOPG) with the stiffening of a composite structure of corneal tissue in particular. Strip tensile tests are conducted to determine their stress-strain relationship for the purpose to study the behaviour of material properties of cornea. Specimens are taken from the superior-inferior (vertical) and temporal- nasal (horizontal) directions. Testing is performed on an Instron machine, under different rate of loading conditions. First set of experiment, with single strain rate, is executed on eyes having random population. While the second set of experiment is executed on eyes of the same animal in both directions, and different strain rates are applied each specimen. Relatively, the first set of experiment is found to be slightly different and less accurate. In general, it is found that the vertical specimen is 34% on an average stiffer than the horizontal specimen compared to Kampmeier et al. of 20% (studied in 2000) and Defu Wang of 15% (studied in 2007). Curve fitting coefficients are also evaluated for 4-degree polynomial. The anisotropy is evident by plotting the ratio of E-tangent value of vertical Ev and horizontal Eh against stresses with individual strain rates. The value of Ev/Eh increases with slightly slow rate with stresses as compared to achieved through slow strain rates.

  3. Mobile Image Ratiometry: A New Method for Instantaneous Analysis of Rapid Test Strips

    OpenAIRE

    Donald C. Cooper; Bryan Callahan; Phil Callahan; Lee Burnett

    2012-01-01

    Here we describe Mobile Image Ratiometry (MIR), a new method for the automated quantification of standardized rapid immunoassay strips using consumer-based mobile smartphone and tablet cameras. To demonstrate MIR we developed a standardized method using rapid immunotest strips directed against cocaine (COC) and its major metabolite, benzoylecgonine (BE). We performed image analysis of three brands of commercially available dye-conjugated anti-COC/BE antibody test strips in response to three d...

  4. Results of Laboratory Testing of Advanced Power Strips: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L.; Sparn, B.

    2012-08-01

    This paper describes the results of a laboratory investigation to evaluate the technical performance of advanced power strip (APS) devices when subjected to a range of home entertainment center and home office usage scenarios.

  5. Comparison between three option, four option and five option multiple choice question tests for quality parameters: A randomized study.

    Science.gov (United States)

    Vegada, Bhavisha; Shukla, Apexa; Khilnani, Ajeetkumar; Charan, Jaykaran; Desai, Chetna

    2016-01-01

    Most of the academic teachers use four or five options per item of multiple choice question (MCQ) test as formative and summative assessment. Optimal number of options in MCQ item is a matter of considerable debate among academic teachers of various educational fields. There is a scarcity of the published literature regarding the optimum number of option in each item of MCQ in the field of medical education. To compare three options, four options, and five options MCQs test for the quality parameters - reliability, validity, item analysis, distracter analysis, and time analysis. Participants were 3 rd semester M.B.B.S. students. Students were divided randomly into three groups. Each group was given one set of MCQ test out of three options, four options, and five option randomly. Following the marking of the multiple choice tests, the participants' option selections were analyzed and comparisons were conducted of the mean marks, mean time, validity, reliability and facility value, discrimination index, point biserial value, distracter analysis of three different option formats. Students score more ( P = 0.000) and took less time ( P = 0.009) for the completion of three options as compared to four options and five options groups. Facility value was more ( P = 0.004) in three options group as compared to four and five options groups. There was no significant difference between three groups for the validity, reliability, and item discrimination. Nonfunctioning distracters were more in the four and five options group as compared to three option group. Assessment based on three option MCQs is can be preferred over four option and five option MCQs.

  6. Testing option pricing with the Edgeworth expansion

    Science.gov (United States)

    Balieiro Filho, Ruy Gabriel; Rosenfeld, Rogerio

    2004-12-01

    There is a well-developed framework, the Black-Scholes theory, for the pricing of contracts based on the future prices of certain assets, called options. This theory assumes that the probability distribution of the returns of the underlying asset is a Gaussian distribution. However, it is observed in the market that this hypothesis is flawed, leading to the introduction of a fudge factor, the so-called volatility smile. Therefore, it would be interesting to explore extensions of the Black-Scholes theory to non-Gaussian distributions. In this paper, we provide an explicit formula for the price of an option when the distributions of the returns of the underlying asset is parametrized by an Edgeworth expansion, which allows for the introduction of higher independent moments of the probability distribution, namely skewness and kurtosis. We test our formula with options in the Brazilian and American markets, showing that the volatility smile can be reduced. We also check whether our approach leads to more efficient hedging strategies of these instruments.

  7. Performance of a new test strip for freestyle blood glucose monitoring systems.

    Science.gov (United States)

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  8. Engineering test of stripping performance by multi-centrifugal contactors system for spent nuclear reprocessing

    International Nuclear Information System (INIS)

    Masayuki Takeuchi; Tadahiro Washiya; Hiroki Nakabayashi; Takashi Suganuma; Shinnichi Aose

    2005-01-01

    Japan Nuclear Cycle Development Institute (JNC) has been developing centrifugal contactors which are compact and high performance for solvent extraction process in industrial reprocessing plant. The stripping performance including equilibrium time for distribution and hydraulic behavior of the multi-centrifugal contactors were mainly evaluated by using uranium nitrite solution on engineering scale (10 kgHM/hr). In particular, the effects of feed temperature of stripping solution and O/A on the stripping performance were focused in this test. As results, no hydraulic problem such as overflow and entrainment were observed in multi-centrifugal contactors system through all conditions, and the uranium and acid concentrations showed desirable profiles which were nearly consistent with calculated one by MIXSET-X code. As to stripping performance, uranium leak concentration in solvent reached to less than 0.01 g/L, which is target of the stripping performance on this centrifugal contactors system, within nine stages on all conditions. It was also found that the effect of feed temperature of stripping solution (35 degree C → 60 degree C) or O/A (1.0→0.8) on stripping performance corresponds to distribution capacity of two contactors, respectively. The stage efficiency for a contactor was estimated as 97-98% on stripping stage. There were no uranium leaks (less than 40μg/L) in spent solvent discharged from the final stage. The profiles of uranium concentration in multi-contactors become stable within 10 minutes after the stripping test starting. In this way, it was demonstrated that the centrifugal contactors system has good stripping performance on engineering scale. (authors)

  9. Advanced Demonstration and Test Reactor Options Study

    Energy Technology Data Exchange (ETDEWEB)

    Petti, David Andrew [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hill, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Gehin, J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gougar, Hans David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Strydom, Gerhard [Idaho National Lab. (INL), Idaho Falls, ID (United States); Heidet, F. [Argonne National Lab. (ANL), Argonne, IL (United States); Kinsey, J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Grandy, Christopher [Argonne National Lab. (ANL), Argonne, IL (United States); Qualls, A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Brown, Nicholas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Powers, J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoffman, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Croson, D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    Global efforts to address climate change will require large-scale decarbonization of energy production in the United States and elsewhere. Nuclear power already provides 20% of electricity production in the United States (U.S.) and is increasing in countries undergoing rapid growth around the world. Because reliable, grid-stabilizing, low emission electricity generation, energy security, and energy resource diversity will be increasingly valued, nuclear power’s share of electricity production has a potential to grow. In addition, there are non electricity applications (e.g., process heat, desalination, hydrogen production) that could be better served by advanced nuclear systems. Thus, the timely development, demonstration, and commercialization of advanced nuclear reactors could diversify the nuclear technologies available and offer attractive technology options to expand the impact of nuclear energy for electricity generation and non-electricity missions. The purpose of this planning study is to provide transparent and defensible technology options for a test and/or demonstration reactor(s) to be built to support public policy, innovation and long term commercialization within the context of the Department of Energy’s (DOE’s) broader commitment to pursuing an “all of the above” clean energy strategy and associated time lines. This planning study includes identification of the key features and timing needed for advanced test or demonstration reactors to support research, development, and technology demonstration leading to the commercialization of power plants built upon these advanced reactor platforms. This planning study is consistent with the Congressional language contained within the fiscal year 2015 appropriation that directed the DOE to conduct a planning study to evaluate “advanced reactor technology options, capabilities, and requirements within the context of national needs and public policy to support innovation in nuclear energy

  10. Advanced Demonstration and Test Reactor Options Study

    International Nuclear Information System (INIS)

    Petti, David Andrew; Hill, R.; Gehin, J.; Gougar, Hans David; Strydom, Gerhard; Heidet, F.; Kinsey, J.; Grandy, Christopher; Qualls, A.; Brown, Nicholas; Powers, J.; Hoffman, E.; Croson, D.

    2017-01-01

    Global efforts to address climate change will require large-scale decarbonization of energy production in the United States and elsewhere. Nuclear power already provides 20% of electricity production in the United States (U.S.) and is increasing in countries undergoing rapid growth around the world. Because reliable, grid-stabilizing, low emission electricity generation, energy security, and energy resource diversity will be increasingly valued, nuclear power's share of electricity production has a potential to grow. In addition, there are non electricity applications (e.g., process heat, desalination, hydrogen production) that could be better served by advanced nuclear systems. Thus, the timely development, demonstration, and commercialization of advanced nuclear reactors could diversify the nuclear technologies available and offer attractive technology options to expand the impact of nuclear energy for electricity generation and non-electricity missions. The purpose of this planning study is to provide transparent and defensible technology options for a test and/or demonstration reactor(s) to be built to support public policy, innovation and long term commercialization within the context of the Department of Energy's (DOE's) broader commitment to pursuing an 'all of the above' clean energy strategy and associated time lines. This planning study includes identification of the key features and timing needed for advanced test or demonstration reactors to support research, development, and technology demonstration leading to the commercialization of power plants built upon these advanced reactor platforms. This planning study is consistent with the Congressional language contained within the fiscal year 2015 appropriation that directed the DOE to conduct a planning study to evaluate 'advanced reactor technology options, capabilities, and requirements within the context of national needs and public policy to support innovation in nuclear energy'. Advanced reactors are

  11. An Optical Test Strip for the Detection of Benzoic Acid in Food

    Directory of Open Access Journals (Sweden)

    Fatimah Abu Bakar

    2011-07-01

    Full Text Available Fabrication of a test strip for detection of benzoic acid was successfully implemented by immobilizing tyrosinase, phenol and 3-methyl-2-benzothiazolinone hydrazone (MBTH onto filter paper using polystyrene as polymeric support. The sensing scheme was based on the decreasing intensity of the maroon colour of the test strip when introduced into benzoic acid solution. The test strip was characterized using optical fiber reflectance and has maximum reflectance at 375 nm. It has shown a highly reproducible measurement of benzoic acid with a calculated RSD of 0.47% (n = 10. The detection was optimized at pH 7. A linear response of the biosensor was obtained in 100 to 700 ppm of benzoic acid with a detection limit (LOD of 73.6 ppm. At 1:1 ratio of benzoic acid to interfering substances, the main interfering substance is boric acid. The kinetic analyses show that, the inhibition of benzoic is competitive inhibitor and the inhibition constant (Ki is 52.9 ppm. The activity of immobilized tyrosinase, phenol, and MBTH in the test strip was fairly sustained during 20 days when stored at 3 °C. The developed test strip was used for detection of benzoic acid in food samples and was observed to have comparable results to the HPLC method, hence the developed test strip can be used as an alternative to HPLC in detecting benzoic acid in food products.

  12. Extraction, scrub, and strip test results for the solvent transfer to salt waste processing facility

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-09-07

    The Savannah River National Laboratory (SRNL) prepared approximately 240 gallons of Caustic-Side Solvent Extraction (CSSX) solvent for use at the Salt Waste Processing Facility (SWPF). An Extraction, Scrub, and Strip (ESS) test was performed on a sample of the prepared solvent using a salt solution prepared by Parsons to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help qualify the solvent for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 15.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

  13. Accelerated life test of an ONO stacked insulator film for a silicon micro-strip detector

    International Nuclear Information System (INIS)

    Okuno, Shoji; Ikeda, Hirokazu; Saitoh, Yutaka

    1996-01-01

    We have used to acquire the signal through an integrated capacitor for a silicon micro-strip detector. When we have been using a double-sided silicon micro-strip detector, we have required a long-term stability and a high feasibility for the integrated capacitor. An oxide-nitride-oxide (ONO) insulator film was theoretically expected to have a superior nature in terms of long term reliability. In order to test long term reliability for integrated capacitor of a silicon micro-strip detector, we made a multi-channel measuring system for capacitors

  14. Results from a beam test of silicon strip sensors manufactured by Infineon Technologies AG

    Energy Technology Data Exchange (ETDEWEB)

    Dragicevic, M., E-mail: marko.dragicevic@oeaw.ac.at [Institute of High Energy Physics, Austrian Academy of Sciences, Vienna (Austria); Auzinger, G. [Institute of High Energy Physics, Austrian Academy of Sciences, Vienna (Austria); CERN, Geneva (Switzerland); Bartl, U. [Infineon Technologies Austria AG, Villach (Austria); Bergauer, T. [Institute of High Energy Physics, Austrian Academy of Sciences, Vienna (Austria); Gamerith, S.; Hacker, J. [Infineon Technologies Austria AG, Villach (Austria); König, A. [Institute of High Energy Physics, Austrian Academy of Sciences, Vienna (Austria); Infineon Technologies Austria AG, Villach (Austria); Kröner, F.; Kucher, E.; Moser, J.; Neidhart, T. [Infineon Technologies Austria AG, Villach (Austria); Schulze, H.-J. [Infineon Technologies AG, Munich (Germany); Schustereder, W. [Infineon Technologies Austria AG, Villach (Austria); Treberspurg, W. [Institute of High Energy Physics, Austrian Academy of Sciences, Vienna (Austria); Wübben, T. [Infineon Technologies Austria AG, Villach (Austria)

    2014-11-21

    Most modern particle physics experiments use silicon based sensors for their tracking systems. These sensors are able to detect particles generated in high energy collisions with high spatial resolution and therefore allow the precise reconstruction of particle tracks. So far only a few vendors were capable of producing silicon strip sensors with the quality needed in particle physics experiments. Together with the European-based semiconductor manufacturer Infineon Technologies AG (Infineon) the Institute of High Energy Physics of the Austrian Academy of Sciences (HEPHY) developed planar silicon strip sensors in p-on-n technology. This work presents the first results from a beam test of strip sensors manufactured by Infineon.

  15. Anodic stripping voltammetry of gold nanoparticles at boron-doped diamond electrodes and its application in immunochromatographic strip tests.

    Science.gov (United States)

    Ivandini, Tribidasari A; Wicaksono, Wiyogo P; Saepudin, Endang; Rismetov, Bakhadir; Einaga, Yasuaki

    2015-03-01

    Anodic stripping voltammetry (ASV) of colloidal gold-nanoparticles (AuNPs) was investigated at boron-doped diamond (BDD) electrodes in 50 mM HClO4. A deposition time of 300 s at-0.2 V (vs. Ag/AgCl) was fixed as the condition for the ASV. The voltammograms showed oxidation peaks that could be attributed to the oxidation of gold. These oxidation peaks were then investigated for potential application in immunochromatographic strip tests for the selective and quantitative detection of melamine, in which AuNPs were used as the label for the antibody of melamine. Linear regression of the oxidation peak currents appeared in the concentration range from 0.05-0.6 μg/mL melamine standard, with an estimated LOD of 0.069 μg/mL and an average relative standard deviation of 8.0%. This indicated that the method could be considered as an alternative method for selective and quantitative immunochromatographic applications. The validity was examined by the measurements of melamine injected into milk samples, which showed good recovery percentages during the measurements. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Performance tests of developed silicon strip detector by using a 150 GeV electron beam

    International Nuclear Information System (INIS)

    Hyun, Hyojung; Jung, Sunwoo; Kah, Dongha; Kang, Heedong; Kim, Hongjoo; Park, Hwanbae

    2008-01-01

    We manufactured and characterized a silicon micro-strip detector to be used in a beam tracker. A silicon detector features a DC-coupled silicon strip sensor with VA1 Prime2 analog readout chips. The silicon strip sensors have been fabricated on 5-in. wafers at Electronics and Telecommunications Research Institute (Daejeon, Korea). The silicon strip sensor is single-sided and has 32 channels with a 1 mm pitch, and its active area is 3.2 by 3.2 cm 2 with 380 μm thickness. The readout electronics consists of VA hybrid, VA Interface, and FlashADC and Control boards. Analog signals from the silicon strip sensor were being processed by the analog readout chips on the VA hybrid board. Analog signals were then changed into digital signals by a 12 bit 25 MHz FlashADC. The digital signals were read out by the Linux-operating PC through the FlashADC-USB2 interface. The DAQ system and analysis programs were written in the framework of ROOT package. The beam test with the silicon detector had been performed at CERN beam facility. We used a 150 GeV electron beam out of the SPS(Super Proton Synchrotron) H2 beam line. We present beam test setup and measurement result of signal-to-noise ratio of each strip channel. (author)

  17. The stripping foil test stand in the Linac4 transfer line

    CERN Document Server

    Weterings, W; Noulibos, R; Sillanoli, Y; van Trappen, P

    2015-01-01

    The 160 MeV H− beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H− charge-exchange injection system. It will include a stripping foil, to convert H− into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters.

  18. The stripping foil test stand in the Linac4 transfer line

    International Nuclear Information System (INIS)

    Weterings, W.; Bracco, C.; Noulibos, R.; Sillanoli, Y.; Trappen van, P.

    2015-01-01

    The 160 MeV H - beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H - charge-exchange injection system. It will include a stripping foil, to convert H - into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters. (author)

  19. Initial beam test results from a silicon-strip detector with VLSI readout

    International Nuclear Information System (INIS)

    Adolphsen, C.; Litke, A.; Schwarz, A.

    1986-01-01

    Silicon detectors with 256 strips, having a pitch of 25 μm, and connected to two 128 channel NMOS VLSI chips each (Microplex), have been tested in relativistic charged particle beams at CERN and at the Stanford Linear Accelerator Center. The readout chips have an input channel pitch of 47.5 μm and a single multiplexed output which provides voltages proportional to the integrated charge from each strip. The most probable signal height from minimum ionizing tracks was 15 times the rms noise in any single channel. Two-track traversals with a separation of 100 μm were cleanly resolved

  20. Tests of Scintillator+WLS Strips for Muon System at Future Colliders

    Energy Technology Data Exchange (ETDEWEB)

    Denisov, Dmitri [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Evdokimov, Valery [Inst. for High Energy Physics (IHEP), Protvino (Russian Federation); Lukić, Strahinja [Univ. of Belgrade (Serbia)

    2015-10-11

    Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been achieved, as well as time resolution of 0.5 ns and position resolution of ~ 7 cm.

  1. Evaluation of commercial glucometer test strips for potential measurement of glucose in tears.

    Science.gov (United States)

    Cha, Kyoung Ha; Jensen, Gary C; Balijepalli, Anant S; Cohan, Bruce E; Meyerhoff, Mark E

    2014-02-04

    Tear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported that there is a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. Herein, we evaluate the potential of using commercial blood glucose test strips to measure glucose in tears. Of several blood glucose strips evaluated, only one brand exhibits the low detection limit required for quantitating glucose in tears. Calibration of these strips in the range of 0-100 μM glucose with an applied potential of 150 mV to the working electrode yields a sensitivity of 0.127 nA/μM and a limit of quantitation (LOQ) of 9 μM. The strips also exhibit ≤13% error (n = 3) for 25, 50, and 75 μM glucose in the presence of 10 μM acetaminophen, 100 μM ascorbic acid, and 100 μM uric acid. Measurements of glucose in tears from nine normal (nondiabetic) fasting human subjects using strips yielded glucose values within the range of 5-148 μM (mean = 47 μM, median = 43 μM), similar to those for human tears reported by others with more complex LC-MS methods. The glucometer strip method could facilitate more clinical studies to determine whether tear glucose and blood glucose levels sufficiently correlate for application to routine measurements in tears to supplement blood glucose testing. This would be especially helpful for children, adolescents, other Type 1 diabetics, and also for Type 2 diabetics who require treatment with insulin and cannot tolerate multiple finger sticks per day.

  2. Screening the performance of lubricants for ironing of stainless steel with a strip reduction test

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Bay, Niels; Andersen, Mette Merete

    1997-01-01

    A laboratory strip reduction test simulating the tribological conditions of an ironing process is proposed. The test is capable of simulating varying process conditions such as reduction, drawing speed, tool temperature and sliding length. The test makes it possible to quantify the onset of break...... of breakdown of the lubricant film and subsequent galling. Experimental investigations of stainless steel show the influence of varying process conditions and the performance of different lubricants.......A laboratory strip reduction test simulating the tribological conditions of an ironing process is proposed. The test is capable of simulating varying process conditions such as reduction, drawing speed, tool temperature and sliding length. The test makes it possible to quantify the onset...

  3. Comparison of Urine Albumin-to-Creatinine Ratio (ACR) Between ACR Strip Test and Quantitative Test in Prediabetes and Diabetes

    Science.gov (United States)

    Cho, Seon; Kim, Suyoung; Cho, Han-Ik

    2017-01-01

    Background Albuminuria is generally known as a sensitive marker of renal and cardiovascular dysfunction. It can be used to help predict the occurrence of nephropathy and cardiovascular disorders in diabetes. Individuals with prediabetes have a tendency to develop macrovascular and microvascular pathology, resulting in an increased risk of retinopathy, cardiovascular diseases, and chronic renal diseases. We evaluated the clinical value of a strip test for measuring the urinary albumin-to-creatinine ratio (ACR) in prediabetes and diabetes. Methods Spot urine samples were obtained from 226 prediabetic and 275 diabetic subjects during regular health checkups. Urinary ACR was measured by using strip and laboratory quantitative tests. Results The positive rates of albuminuria measured by using the ACR strip test were 15.5% (microalbuminuria, 14.6%; macroalbuminuria, 0.9%) and 30.5% (microalbuminuria, 25.1%; macroalbuminuria, 5.5%) in prediabetes and diabetes, respectively. In the prediabetic population, the sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of the ACR strip method were 92.0%, 94.0%, 65.7%, 99.0%, and 93.8%, respectively; the corresponding values in the diabetic population were 80.0%, 91.6%, 81.0%, 91.1%, and 88.0%, respectively. The median [interquartile range] ACR values in the strip tests for measurement ranges of 300 mg/g were 9.4 [6.3-15.4], 46.9 [26.5-87.7], and 368.8 [296.2-575.2] mg/g, respectively, using the laboratory method. Conclusions The ACR strip test showed high sensitivity, specificity, and negative predictive value, suggesting that the test can be used to screen for albuminuria in cases of prediabetes and diabetes. PMID:27834062

  4. Reagent strip testing is not sensitive for the screening of asymptomatic bacteriuria in pregnant women.

    Science.gov (United States)

    Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada

    2002-08-01

    The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.

  5. Laboratory testing of the in-well vapor-stripping system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Francois, O.

    1996-03-01

    The Volatile organic Compounds-Arid Integrated Demonstration (VOC-Arid ID) was implemented by the US Department of Energy's (DOE's) Office of Technology Development to develop and test new technologies for the remediation of organic chemicals in the subsurface. One of the technologies being tested under the VOC-Arid ID is the in-well vapor-stripping system. The in-well vapor-stripping concept was initially proposed by researchers at Stanford University and is currently under development through a collaboration between workers at Stanford University and DOE's Pacific Northwest National Laboratory. The project to demonstrate the in-well vapor-stripping technology is divided into three phases: (1) conceptual model and computer simulation, (2) laboratory testing, and (3) field demonstration. This report provides the methods and results of the laboratory testing in which a full-scale replica was constructed and tested above ground in a test facility located at DOE's Hanford Site, Washington. The system is a remediation technology designed to preferentially extract volatile organic compounds (VOCs) from contaminated groundwater by converting them to a vapor phase

  6. Comparison of agar dilution and antibiotic gradient strip test with broth microdilution for susceptibility testing of swine Brachyspira species.

    Science.gov (United States)

    Mirajkar, Nandita S; Gebhart, Connie J

    2016-03-01

    Production-limiting diseases in swine caused by Brachyspira are characterized by mucohemorrhagic diarrhea (B. hyodysenteriae and "B. hampsonii") or mild colitis (B. pilosicoli), while B. murdochii is often isolated from healthy pigs. Emergence of novel pathogenic Brachyspira species and strains with reduced susceptibility to commonly used antimicrobials has reinforced the need for standardized susceptibility testing. Two methods are currently used for Brachyspira susceptibility testing: agar dilution (AD) and broth microdilution (BMD). However, these tests have primarily been used for B. hyodysenteriae and rarely for B. pilosicoli. Information on the use of commercial susceptibility testing products such as antibiotic gradient strips is lacking. Our main objective was to validate and compare the susceptibility results, measured as the minimum inhibitory concentration (MIC), of 6 antimicrobials for 4 Brachyspira species (B. hyodysenteriae, "B. hampsonii", B. pilosicoli, and B. murdochii) by BMD and AD (tiamulin, valnemulin, lincomycin, tylosin, and carbadox) or antibiotic gradient strip (doxycycline) methods. In general, the results of a high percentage of all 4 Brachyspira species differed by ±1 log2 dilution or less by BMD and AD for tiamulin, valnemulin, lincomycin, and tylosin, and by BMD and antibiotic gradient strip for doxycycline. The carbadox MICs obtained by BMD were 1-5 doubling dilutions different than those obtained by AD. BMD for Brachyspira was quicker to perform with less ambiguous interpretation of results when compared with AD and antibiotic gradient strip methods, and the results confirm the utility of BMD in routine diagnostics. © 2016 The Author(s).

  7. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  8. A micro-strip gas counter test with the RD20 front-end

    International Nuclear Information System (INIS)

    Clergeau, J.F.; Contardo, D.; Haroutunian, R.; Smadja, G.

    1994-05-01

    A Micro-Strip Gas Counter equipped with the VLSI preamplifier of the RD20 chip has been tested with minimum ionizing particles. The measured pulse shape and the signal to noise ratio are presented. The time resolution of the detector is compared for the Ar/DME and DME/CO 2 gas mixtures. Three methods for the bunch crossing identification at LHC are discussed. (authors). 5 refs., 7 figs., 3 tabs

  9. Application of strip-reduction-test in hte evaluation of lubricants developed in Enform project

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Gazvoda, S.

    2001-01-01

    The performance of three different lubricants in relation to sheet metal forming of steel, Zinc coated steel and stainless steel is investigated in the present paper. A strip reduction test simulating can wall ironing is used. The test was originally developed for determining the limits...... of lubrication in forming of stainless steel by quantification of the degree of galling. The present results show that the test methodology to some extend can be used in testing of lubricants for Zinc coated steels whereas the lubricant performance in forming of steel is more complicated to quantify since...

  10. Radiation hardness tests of double-sided 3D strip sensors with passing-through columns

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Betta, Gian-Franco, E-mail: gianfranco.dallabetta@unitn.it [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); INFN TIFPA, Via Sommarive 14, I-38123 Trento (Italy); Betancourt, Christopher [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Boscardin, Maurizio; Giacomini, Gabriele [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi (FBK-CMM), Via Sommarive 18, I-38123 Trento (Italy); Jakobs, Karl; Kühn, Susanne [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Lecini, Besnik [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); Mendicino, Roberto [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); INFN TIFPA, Via Sommarive 14, I-38123 Trento (Italy); Mori, Riccardo; Parzefall, Ulrich [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Povoli, Marco [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); Thomas, Maira [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Zorzi, Nicola [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi (FBK-CMM), Via Sommarive 18, I-38123 Trento (Italy)

    2014-11-21

    This paper deals with a radiation hardness study performed on double-sided 3D strip sensors with passing-through columns. Selected results from the characterization of the irradiated sensors with a beta source and a laser setup are reported and compared to pre-irradiation results and to TCAD simulations. The sensor performance in terms of signal efficiency is found to be in good agreement with that of other 3D sensors irradiated at the same fluences and tested under similar experimental conditions. - Highlights: • We report results from 3D silicon strip detectors irradiated up to HL-LHC fluences. • I–V curves, noise, charge collection measurements and laser scans are shown. • In all sensors, signals are distinguished from the noise already at low voltage. • Signal efficiency is in agreement with values expected from the electrode geometry. • Efficiency and spatial uniformity would benefit from higher operation voltages.

  11. Radiation hardness tests of double-sided 3D strip sensors with passing-through columns

    International Nuclear Information System (INIS)

    Dalla Betta, Gian-Franco; Betancourt, Christopher; Boscardin, Maurizio; Giacomini, Gabriele; Jakobs, Karl; Kühn, Susanne; Lecini, Besnik; Mendicino, Roberto; Mori, Riccardo; Parzefall, Ulrich; Povoli, Marco; Thomas, Maira; Zorzi, Nicola

    2014-01-01

    This paper deals with a radiation hardness study performed on double-sided 3D strip sensors with passing-through columns. Selected results from the characterization of the irradiated sensors with a beta source and a laser setup are reported and compared to pre-irradiation results and to TCAD simulations. The sensor performance in terms of signal efficiency is found to be in good agreement with that of other 3D sensors irradiated at the same fluences and tested under similar experimental conditions. - Highlights: • We report results from 3D silicon strip detectors irradiated up to HL-LHC fluences. • I–V curves, noise, charge collection measurements and laser scans are shown. • In all sensors, signals are distinguished from the noise already at low voltage. • Signal efficiency is in agreement with values expected from the electrode geometry. • Efficiency and spatial uniformity would benefit from higher operation voltages

  12. A Highly Sensitive Immunochromatographic Strip Test for Rapid and Quantitative Detection of Saikosaponin d

    Directory of Open Access Journals (Sweden)

    Yue Zhang

    2018-02-01

    Full Text Available A quantitative lateral-flow immunoassay using gold nanoparticles (AuNPs conjugated with a monoclonal antibody (MAb against saikosaponin d (SSd was developed for the analysis of SSd. The AuNPs were prepared in our laboratory. The AuNPs were polyhedral, with an average diameter of approximately 18 nm. We used the conjugation between AuNPs and MAbs against SSd to prepare immunochromatographic strips (ICSs. For the quantitative experiment, the strips with the test results were scanned using a membrane strip reader, and a detection curve (regression equation, y = −0.113ln(x + 1.5451, R2 = 0.983, representing the averages of the scanned data, was obtained. This curve was linear from 96 ng/mL to 150 μg/mL, and the IC50 value was 10.39 μg/mL. In this study, we bring the concept of POCT (point-of-care testing to the measurement of TCM compounds, and this is the first report of quantitative detection of SSd by an ICS.

  13. Evaluation of MIC Strip Isavuconazole test for susceptibility testing of wild-type and non-wild-type Aspergillus fumigatus isolates

    DEFF Research Database (Denmark)

    Arendrup, Maiken Cavling; Verweij, Paul; Nielsen, Henrik Vedel

    2017-01-01

    We evaluated the MIC Strip Isavuconazole test against EUCAST E.Def 9.3 by using 40 wild-type and 39 CYP51A mutant Aspergillus fumigatus strains. The strip full inhibition endpoint (FIE) and 80% growth inhibition endpoint were determined by two independent readers, reader 1 (R1) and R2. The essent......We evaluated the MIC Strip Isavuconazole test against EUCAST E.Def 9.3 by using 40 wild-type and 39 CYP51A mutant Aspergillus fumigatus strains. The strip full inhibition endpoint (FIE) and 80% growth inhibition endpoint were determined by two independent readers, reader 1 (R1) and R2...

  14. Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout

    Energy Technology Data Exchange (ETDEWEB)

    Denisov, Dmitri [Fermilab, Batavia IL (United States); Evdokimov, Valery [Institute for High Energy Physics, Protvino (Russian Federation); Lukić, Strahinja; Ujić, Predrag [Vinča Institute, University of Belgrade (Serbia)

    2017-03-11

    Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed , as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.

  15. Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-06

    An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D(Cs) results.

  16. Extraction, scrub, and strip test results for the salt waste processing facility caustic side solvent extraction solvent example

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-08-01

    An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

  17. Technical performance of lactate biosensors and a test-strip device during labour.

    Science.gov (United States)

    Luttkus, A K; Fotopoulou, C; Sehouli, J; Stupin, J; Dudenhausen, J W

    2010-04-01

    Lactate in fetal blood has a high diagnostic power to detect fetal compromise due to hypoxia, as lactate allows an estimation of duration and intensity of metabolic acidemia. Biosensor technology allows an instantaneous diagnosis of fetal compromise in the delivery room. The goal of the current investigation is to define the preanalytical and analytical biases of this technology under routine conditions in a labour ward in comparison to test-strip technology, which allows measurement of lactate alone. Three lactate biosensors (RapidLab 865, Siemens Medical Solutions Diagnostics, Bad Nauheim, Germany; Radiometer ABL625 and ABL 700, Radiometer Copenhagen, Denmark) and one test-strip device (Lactate Pro, Oxford Instruments, UK) were evaluated regarding precision in serial and repetitive measurements in over 1350 samples of fetal whole blood. The coefficient of variation (CV) and the standard deviation (SD) were calculated. The average value of all three biosensors was defined as an artificial reference value (refval). Blood tonometry was performed in order to test the quality of respiratory parameters and to simulate conditions of fetal hypoxia (pO (2): 10 and 20 mmHg). The precision of serial measurements of all biosensors indicated a coefficient of variation (CV) between 1.55 and 3.16% with an SD from 0.042 to 0.053 mmol/L. The test-strip device (Lactate Pro) mounted to 0.117 mmol/L and 3.99% (SD, CV). When compared to our reference value (refval) ABL 625 showed the closest correlation of -0.1%, while Siemens RapidLab 865 showed an overestimation of +8.9%, ABL700 an underestimation of -6.2% and Lactate Pro of -3.7%. For routine use all tested biosensors show sufficient precision. The test-strip device shows a slightly higher standard deviation. A direct comparison of measured lactate values from the various devices needs to be interpreted with caution as each method detects different lactate concentrations. Furthermore, the 40 min process of tonometry led to an

  18. Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent

    Energy Technology Data Exchange (ETDEWEB)

    Washington, A. L. II [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-03-03

    This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tank 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or DCs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction DCs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material.

  19. A simple and rapid immunochromatographic test strip for detection of pathogenic isolates of Vibrio harveyi.

    Science.gov (United States)

    Sithigorngul, Paisarn; Rukpratanporn, Sombat; Pecharaburanin, Nilawan; Suksawat, Pornthip; Longyant, Siwaporn; Chaivisuthangkura, Parin; Sithigorngul, Weerawan

    2007-12-01

    Mouse monoclonal antibodies (MAbs) and rabbit polyclonal antibody (PAb) against Vibrio harveyi were generated from immunization of mice and rabbits with highly virulent isolate of V. harveyi. Two MAbs specific to virulent isolates of V. harveyi were obtained and one of them (VH4) was selected to conjugate with colloidal gold as the detector antibody was laid on a sample pad. Rabbit polyclonal antibody was used as the capture antibody at the test line (T) and goat anti-mouse IgG antibody (GAM) was used as the capture antibody at the control line (C) of nitrocellulose strip. The ready-to-use strip was held in a plastic case and then stored in a desiccated plastic bag. A sample volume of 100 microl of bacterial suspension from various sources mixed with application buffer was applied to the sample chamber at one end of the strip and allowed to flow by chromatography through the nitrocellulose membrane to the other end. In test samples containing virulent isolates of V. harveyi, the bacteria would bind to the monoclonal antibody conjugated with colloidal gold and the resulting complex would be captured by the antibodies at the test line to give a reddish-purple band. Any unbound monoclonal antibody conjugated with colloidal gold moved across the test line would be captured by the GAM and form a band at the control line (C). In sample without V. harveyi or with V. harveyi below the limit (culture. The beneficial features of this kit are that simple, convenient and quick results (within 15 min) can be obtained without the requirement of sophisticated tools or special equipments and skills.

  20. Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent

    International Nuclear Information System (INIS)

    Washington, A. L. II; Peters, T. B.

    2014-01-01

    This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tank 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or DCs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction DCs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material

  1. A test-bench for measurement of electrical static parameters of strip silicon detectors

    International Nuclear Information System (INIS)

    Golutvin, I.A.; Dmitriev, A.Yu.; Elsha, V.V.

    2003-01-01

    An automated test-bench for electrical parameters input control of the strip silicon detectors, used in the End-Cap Preshower detector of the CMS experiment, is described. The test-bench application allows one to solve a problem of silicon detectors input control in conditions of mass production - 1800 detectors over 2 years. The test-bench software is realized in Delphi environment and contains a user-friendly operator interface for data processing and visualization as well as up-to-date facilities for MS-Windows used for the network database. High operating characteristics and reliability of the test-bench were confirmed while more than 800 detectors were tested. Some technical solutions applied to the test-bench could be useful for design and construction of automated facilities for electrical parameters measurements of the microstrip detectors input control. (author)

  2. A Test-Bench for Measurement of Electrical Static Parameters of Strip Silicon Detectors

    CERN Document Server

    Golutvin, I A; Danilevich, V G; Dmitriev, A Yu; Elsha, V V; Zamiatin, Y I; Zubarev, E V; Ziaziulia, F E; Kozus, V I; Lomako, V M; Stepankov, D V; Khomich, A P; Shumeiko, N M; Cheremuhin, A E

    2003-01-01

    An automated test-bench for electrical parameters input control of the strip silicon detectors, used in the End-Cap Preshower detector of the CMS experiment, is described. The test-bench application allows one to solve a problem of silicon detectors input control in conditions of mass production - 1800 detectors over 2 years. The test-bench software is realized in Delphi environment and contains a user-friendly operator interface for measurement data processing and visualization as well as up-to-date facilities for MS-Windows used for the network database. High operating characteristics and reliability of the test-bench were confirmed while more than 800 detectors were tested. Some technical solutions applied to the test-bench could be useful for design and construction of automated facilities for electrical parameters measurements of the microstrip detectors input control.

  3. Utility of a rapid immunochromatographic strip test in detecting canine parvovirus infection compared with polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Sundaran S. Tinky

    2015-04-01

    Full Text Available Aim: The present study was undertaken to detect the presence of canine parvovirus (CPV in fecal samples of diarrheic dogs by conventional polymerase chain reaction (PCR and immunochromatographic (IC strip test and to compare the diagnostic potential of these tests. Materials and Methods: A total of 50 fecal samples collected from diarrheic dogs suspected for CPV infection were subjected to PCR using CPV-555 primer amplifying the gene coding for the VP1 protein. These samples were also tested by IC strip test using a commercial rapid Ag test kit. The results were statistically analyzed using McNemar test. Results: A total of 22 samples (44% were detected as positive by PCR, which yielded a specific amplicon of 583 bp. In IC strip test, 18 (36% samples were found to be positive. The sensitivity of the test as compared to PCR was found to be 72.22% and specificity was 92.86%. Positive predictive value and negative predictive value of IC strip test was found to be 88.89% and 81.25%, respectively. Statistical analysis of the results of PCR and IC assay using McNemar test revealed no significant difference (p>0.05. Conclusion: The IC strip test could be employed as a rapid field level diagnostic tool for the diagnosis of canine parvoviral diarrhea.

  4. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  5. Patterns, Policy and Appropriateness: A 12-Year Utilization Review of Blood Glucose Test Strip Use in Insulin Users.

    Science.gov (United States)

    Falk, Jamie; Friesen, Kevin J; Okunnu, Anuoluwapo; Bugden, Shawn

    2017-08-01

    Considerable attention has been paid to the rising costs of the use of blood glucose test strips (BGTS). Insulin users have generally been treated as a single homogeneous group, resulting in policies that cap usage (8.2 strips/day) in provincial drug insurance programs. The objective of this study was to conduct a utilization review of BGTS by insulin users and to evaluate use patterns against current insulin use patterns and BGTS policy. BGTS usage was examined in a cohort of insulin users with type 1 and type 2 diabetes over a 12-year period (2001 to 2013) using the population-based administrative data in Manitoba, Canada. Total BGTS strip use increased by 121%, from $4.3 to $9.5 million. However, the number of insulin users also increased by 115%. Use has been stable at 1.5 strips per day per person since 2004 by insulin users with type 2 diabetes but has risen from 1.9 to 3.0 strips per day per person in those with type 1 diabetes. Mean daily test strip use was below the number of daily tests recommended for patients using insulin as per the current Canadian guidelines, with 11% and 15% of insulin users with type 1 and type 2 diabetes not claiming any BGTS use and a further 15% (type 1) and 28% (type 2) using fewer than 1 strip per day. BGTS use per insulin user has been stable for most of the past decade, and the vast majority of use falls well below provincial insurance caps. The amount of low-level testing (0 to <1 strip/day) suggests that greater attention should be directed to ensuring a safe level of testing by all insulin users. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Effluent treatment options for nuclear thermal propulsion system ground tests

    International Nuclear Information System (INIS)

    Shipers, L.R.; Brockmann, J.E.

    1992-01-01

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the strengths and weaknesses of different methods to handle effluent from nuclear thermal propulsion system ground tests

  7. Use of moisture induced stress testing to evaluate stripping potential of hot mix asphalt (HMA).

    Science.gov (United States)

    2012-07-01

    Stripping of hot mix asphalt (HMA) in the field is an ongoing issue for many Departments of Transportation : (DOTs). A leading cause of stripping is hydraulic scouring. The Moisture Induced Stress Tester (MIST) is a recently : developed technology th...

  8. Diagnosis of rinderpest in Tanzania by a rapid chromatographic strip-test.

    Science.gov (United States)

    Wambura, P N; Moshy, D W; Mbise, A N; Mollel, G O; Taylor, W P; Anderson, J; Bruning, A

    2000-06-01

    A simple chromatographic strip-test based on Clearview technology, is under development as a pen-side test for the detection of rinderpest antigen in eye swabs taken from cattle in the field. An outbreak of rinderpest occurred in the northern zone of Tanzania from late February to June 1997. The affected cattle exhibited very mild clinical signs, which made clinical diagnosis difficult. One hundred and seven eye swabs were collected from cattle suspected of infection with rinderpest. These were tested in the field using a prototype of the pen-side test and 13 (12.15%) of the samples were found to be positive for the presence of rinderpest antigen. These were confirmed by ICE. The positive cases were predominantly found in the Ngorongoro district. This demonstrates the usefulness of such a simple, rapid pen-side diagnostic assay, particularly when clinically 'mild' strains of rinderpest are present.

  9. 7 CFR 51.3418 - Optional test for fry color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Optional test for fry color. 51.3418 Section 51.3418... color. Fry color may be determined in accordance with contract specifications by using the Munsell Color...°F or 21/2 minutes at 375°F. 5 Munsell Color Standards for Frozen French Fried Potatoes, Third...

  10. Options for clean-up of the Maralinga test site

    International Nuclear Information System (INIS)

    1985-06-01

    This report examines the limit of contamination of the soil and ground cover by 239 Pu, 235 U and 241 Am which may be considered as permitting the unrestricted land use of the former nuclear weapon test sites at Emu and Maralinga by Aboriginal groups. It reports on the options available to achieve this objective and their cost

  11. Colorimetric analysis of saliva–alcohol test strips by smartphone-based instruments using machine-learning algorithms

    Science.gov (United States)

    Strip lateral flow assays, similar to a home pregnancy test, are used widely in food safety applications to provide rapid and accurate tests for the presence of specific foodborne pathogens or other contaminants. Though these tests are very rapid, they are not very sensitive, are not quantitative, a...

  12. Towards a point-of-care strip test to diagnose sickle cell anemia.

    Directory of Open Access Journals (Sweden)

    Meaghan Bond

    Full Text Available A rapid test to identify patients with sickle cell disease could have important benefits in low-resource settings. Sickle cell anemia (SCA affects about 300,000 newborns each year, the majority of whom are born in sub-Saharan Africa. Low-cost therapies are available to treat SCA, but most countries in sub-Saharan Africa lack robust neonatal screening programs needed to identify patients in need of treatment. To address this need, we developed and evaluated a competitive lateral flow assay that identifies patients with SCA (genotype HbSS in 15 minutes using undiluted whole blood. A small volume of blood (0.5 μL- 3 μL is mixed with antibody-coated blue latex beads in a tube and applied to the strip. Strips are then placed in a well of running buffer and allowed to run for 10 minutes. Laboratory evaluation with samples containing different proportions of hemoglobin A (HbA and hemoglobin S (HbS indicated that the test should enable identification of SCA patients but not persons with sickle cell trait (SCT. We evaluated the test using 41 samples from individuals with SCA, SCT, and normal blood. With visual inspection or quantitative analysis, we found a 98% accuracy when differentiating SCA from normal and SCT samples as a group (90% sensitivity and 100% specificity for identifying SCA. This work demonstrates important steps towards making a lateral flow test for hemoglobinopathies more appropriate for point-of-care use; further work is needed before the test is appropriate for clinical use.

  13. Development of a multiplex lateral flow strip test for foot-and-mouth disease virus detection using monoclonal antibodies.

    Science.gov (United States)

    Yang, Ming; Caterer, Nigel R; Xu, Wanhong; Goolia, Melissa

    2015-09-01

    Foot-and-mouth disease (FMD) is one of the world's most highly contagious animal diseases with tremendous economic consequences. A rapid and specific test for FMD diagnosis at the site of a suspected outbreak is crucial for the implementation of control measures. This project developed a multiplex lateral flow immunochromatographic strip test (multiplex-LFI) for the rapid detection and serotyping of FMD viruses. The monoclonal antibodies (mAbs) against serotypes O, A, and Asia 1 were used as capture mAbs. The mAbs were conjugated with fluorescein, rhodamine or biotin for serotype O, A and Asia 1, respectively. The detection mAbs which consisted of a serotype-independent mAb in combination with one serotype A-specific mAb and one Asia 1-specific mAb, were each colloidal gold-conjugated. The strips used in this study contained one control line and three test lines, which corresponded to one of the three serotypes, O, A or Asia 1. The newly developed multiplex-LFI strip test specifically identified serotype O (n=46), A (n=45) and Asia 1 (n=17) in all tested field isolates. The sensitivity of this strip test was comparable to the double antibody sandwich ELISA for serotypes O and A, but lower than the ELISA for serotype Asia 1. The multiplex-LFI strip test identified all tissue suspensions from animals that were experimentally inoculated with serotypes O, A or Asia 1. FMD viruses were detected in 38% and 50% of the swab samples from the lesion areas of experimentally inoculated sheep for serotypes O and A, respectively. The capability of the multiplex-LFI strip tests to produce rapid results with high specificity for FMD viruses of multiple serotypes makes this test a valuable tool to detect FMD viruses at outbreak sites. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  14. EVALUASI MEDIUM PENGAYAAN Vibrio cholerae UNTUK DIAGNOSIS KOLERA MENGGUNAKAN IMMUNOCHROMATOGRAPHIC STRIP TEST

    Directory of Open Access Journals (Sweden)

    Kambang Sariadji

    2013-05-01

    Full Text Available Abstract. Vibrio cholerae strains are capable of causing  outbreak cholera in developing country with poor sanitation and hygiene .Conventional culture methods currently available for detection of V. cholerae 01 takes 3 – 5 days. Other diagnostic tools are by using rapid immunochromatographic strip test for controlling and preventing the spreading of cholera outbreak. This method has limitation in detection of V.cholerae O1, especially under 105 cfu/mL. Furthermore rapid method can be improved by  enrichment media and incubation in 37° C for 6 – 8 hours. The aims of research are to analyse enrichments media in increasingl V.cholerae O1, and it’s to improve the finding of the laboratory diagnosis of cholera cases. The research was conducted at the Laboratory of Bacteriology, Center of Biomedical and Basic Technology of Health National Institute of Health Research and Development (NIHRD from January - July 2011. Medium evaluation was done by making serial dilutions of Vibrio cholerae O1 from 107-101 cfu / ml  inoculated into three mediums: alkaline peptone water, bismuth sulfite, and gelatin phosphate salt broth medium. Then were incubated 37°C for 8 hours and every two hours was tested by immunochromatographic strip test. The data analysis to determine treatment and individual differences  each group was done by one way ANOVA test. The results showed that alkali peptone water are better than gelatine phosphate salt broth and bismuth sulfite in increasing V.cholerae O1, p.value 0.000 means significant different. Meanwhile from 24 samples dilutions which were inoculated in three enrichment media, and detected by rapid immunochromatographic in every 2 hours for 8 hours showed positive result in enrichments media are 17 samples for alkali peptone water, 13 samples for gelatine phosphate salt broth  and 8 samples for bismuth sulfite. Key Words : V.Cholerae, Enrichment Media, Immunochromatographic strip test   Abstrak. Vibrio cholerae O1

  15. The Influence of Tool Texture on Friction and Lubrication in Strip Reduction Testing

    DEFF Research Database (Denmark)

    Sulaiman, Mohd Hafis Bin; Christiansen, Peter; Bay, Niels Oluf

    2017-01-01

    While texturing of workpiece surfaces to promote lubrication in metal forming has beenapplied for several decades, tool surface texturing is rather new. In the present paper, tool texturing is studied as a method to prevent galling. A strip reduction test was conducted with tools provided...... with shallow, longitudinal pockets oriented perpendicular to the sliding direction. The pockets had small angles to the workpiece surface and the distance between them were varied. The experiments reveal that the distance between pockets should be larger than the pocket width, thereby creating a topography...... similar to flat table mountains to avoid mechanical interlocking in the valleys; otherwise, an increase in drawing load and pick-up on the tools are observed. The textured tool surface lowers friction and improves lubrication performance, provided that the distance between pockets is 2–4 times larger than...

  16. Disposable glucose test strip for whole blood with integrated sensing/diffusion-limiting layer

    Energy Technology Data Exchange (ETDEWEB)

    Chen Zhencheng [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Fang Cheng, E-mail: fangpingchuan@163.co [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Wang Hongyan; He Jishan [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China)

    2009-12-30

    A disposable glucose test strip with an integrated sensing/diffusion-limiting layer was developed. A formulation containing filler, glucose oxidase and electronic mediator was screen-printed over two carbon electrodes to form an integrated sensing/diffusion-limiting layer. On rehydration, the integrated layer does not break up, but swells to form a gelled and three-dimensional meshy reaction zone on the surface of the underlying conductive elements in which reactants and mediator move freely, but interfering species such as red blood cells containing oxygenated hemoglobin are excluded. On the same time, the integrated layer maintains a rate of permeation of the analyte through it with a variation of less than 10% at temperatures ranging from 15 deg. C to 42 deg. C. This biosensor is substantially insensitive to interferents and essentially independent to relevant temperature, which provides a more reliable reading of actual blood glucose value in human whole blood.

  17. Preliminary Options Assessment of Versatile Irradiation Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Ramazan Sonat [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    The objective of this report is to summarize the work undertaken at INL from April 2016 to January 2017 and aimed at analyzing some options for designing and building a versatile test reactor; the scope of work was agreed upon with DOE-NE. Section 2 presents some results related to KNK II and PRISM Mod A. Section 3 presents some alternatives to the VCTR presented in [ ] as well as a neutronic parametric study to assess the minimum power requirement needed for a 235U metal fueled fast test reactor capable to generate a fast (>100 keV) flux of 4.0 x 1015 n /cm2-s at the test location. Section 4 presents some results regarding a fundamental characteristic of test reactors, namely displacement per atom (dpa) in test samples. Section 5 presents the INL assessment of the ANL fast test reactor design FASTER. Section 6 presents a summary.

  18. The rK39 strip test is non-predictor of clinical status for kala-azar

    Directory of Open Access Journals (Sweden)

    Mohapatra Tribhuban M

    2009-09-01

    Full Text Available Abstract Background The rK39 strip test is reported to be simple, sensitive, specific, non-invasive and economical test. Since this method is supposed to be patient friendly, it may easily be accepted for sero-epidemiological surveys. An attempt was made to evaluate the role of rK39 strip test in pre and post treatment phases of Kala azar, as a diagnostic and prognostic marker, in addition to other laboratory investigations, in order to evaluate its role in sero-epidemiological surveys. Findings A total of 210 cases were selected for the study. One hundred clinically and parasitologically confirmed cases were corroborated with other hematological profiles. The formol-gel test was included along with well matched control group comprising of normal endemic controls (50, non-endemic normals (20 and other febrile cases (40. All groups were tested by rK39 strip test. Fifty Kala azar cases were followed up after completion of successful treatment. They were subjected to rK39 strip test after 0, 90 and 180 days of completion of successful treatment. The rK39 showed sensitivity, specificity, PPV, NPV, and diagnostic accuracy of 98% (95% CI 91.7-100, 100%, 100%, 90% (95% CI 66-100 and 98% (95% CI 92.6-100 respectively. All the 50 cured followed up cases showed positive result by rK39 strip test even after 180 days of completion of successful treatment. Conclusion The test seems an ideal qualitative test for the diagnosis of kala-azar. But for sero-epidemiological studies the test may be used with other parameters. Alternatively a quantitative ELISA using rK39 antigen may be used.

  19. Rapid and quantitative detection of C-reactive protein using quantum dots and immunochromatographic test strips

    Directory of Open Access Journals (Sweden)

    Cheng X

    2014-12-01

    Full Text Available Xianglin Cheng,1,* Xu Pu,2,* Pen Jun,3 XiaoBo Zhu,3 Di Zhu,4 Ming Chen1 1Department of Laboratory Medicine, First Affiliated Hospital of Yangtze University, Jingzhou, 2Department of Laboratory Medicine, RenMin Hospital of Wuhan University, Wuhan, 3Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei, People’s Republic of China; 4Department of Medical Oncology, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA *These authors contributed equally to this study and share first authorship Background: Rapid immunochromatographic tests can detect disease markers in 10–15 minutes, which facilitates clinical diagnosis and treatment programs. However, most immunochromatographic tests employ gold nanoparticles as reporters, and these have only moderate sensitivity and act as qualitative methods for analyzing high biomarker concentrations. Methods: In this study, we introduce quantum dots (QDs as fluorescent probes and immunochromatographic strips to develop quantitative fluorescence point-of-care tests (QF-POCT to analyze C-reactive protein (CRP levels. Goat anti-rabbit IgG and rabbit IgG were used as control antibodies, and mouse monoclonal CRP antibody pairs were used for disease marker detection. One monoclonal CRP antibody was conjugated with QDs and served as a signal antibody, and the other monoclonal CRP antibody was dispensed onto the nitrocellulose membrane and served as a capturing antibody. In the presence of CRP, the fluorescence intensity of the monoclonal antibody-CRP-monoclonal antibody sandwich complex captured on the nitrocellulose membrane was determined using the fluorescence strip reader. Results: QF-POCT assays could quantitatively analyze the concentration of CRP in 15 minutes had a detection limit of 0.25 mg/L, and had a wide detection linearity range (0.5–300 mg/L. The intra-assay and interassay

  20. Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.

    Science.gov (United States)

    Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua

    2015-12-15

    Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Test beam results of a low-pressure micro-strip gas chamber with a secondary-electron emitter

    International Nuclear Information System (INIS)

    Kwan, S.; Anderson, D.F.; Zimmerman, J.; Sbarra, C.; Salomon, M.

    1994-10-01

    We present recent results, from a beam test, on the angular dependence of the efficiency and the distribution of the signals on the anode strips of a low-pressure microstrip gas chamber with a thick CsI layer as a secondary-electron emitter. New results of CVD diamond films as secondary-electron emitters are discussed

  2. The bacterial contamination rate of glucose meter test strips in the hospital setting

    Science.gov (United States)

    Al-Rubeaan, Khalid A.; Saeb, Amr T. M.; AlNaqeb, Dhekra M.; AlQumaidi, Hamed M.; AlMogbel, Turki A.

    2016-01-01

    Objectives: To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. Methods: This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saudi Arabia during the period from August to September 2014 to assess the bacterial contamination rate of the unused strips. A total of 10,447 strips were cultured using proper agar media and incubated both aerobically and anaerobically. Results: The total bacterial contamination rate for the multi-use vials glucose strips was 31.7%, while single-use packed strips were not contaminated at all. Ministry of Health hospitals had the highest contamination rates compared with other hospitals. Critical, obstetric, and surgical wards had the highest bacterial isolates number, where most were in the risk group 3 according to the National Institute of Health guidelines. Staphylococcus species were the most common bacteria found. Conclusion: Glucose meter strips should be recognized as a source of bacterial contamination that could be behind serious hospital acquired infections. The hospital infection control team should adopt proper measures to implement protocols for glucose meter cleaning and glucose strips handling. PMID:27570855

  3. Review of Nuclear Thermal Propulsion Ground Test Options

    Science.gov (United States)

    Coote, David J.; Power, Kevin P.; Gerrish, Harold P.; Doughty, Glen

    2015-01-01

    High efficiency rocket propulsion systems are essential for humanity to venture beyond the moon. Nuclear Thermal Propulsion (NTP) is a promising alternative to conventional chemical rockets with relatively high thrust and twice the efficiency of highest performing chemical propellant engines. NTP utilizes the coolant of a nuclear reactor to produce propulsive thrust. An NTP engine produces thrust by flowing hydrogen through a nuclear reactor to cool the reactor, heating the hydrogen and expelling it through a rocket nozzle. The hot gaseous hydrogen is nominally expected to be free of radioactive byproducts from the nuclear reactor; however, it has the potential to be contaminated due to off-nominal engine reactor performance. NTP ground testing is more difficult than chemical engine testing since current environmental regulations do not allow/permit open air testing of NTP as was done in the 1960's and 1970's for the Rover/NERVA program. A new and innovative approach to rocket engine ground test is required to mitigate the unique health and safety risks associated with the potential entrainment of radioactive waste from the NTP engine reactor core into the engine exhaust. Several studies have been conducted since the ROVER/NERVA program in the 1970's investigating NTP engine ground test options to understand the technical feasibility, identify technical challenges and associated risks and provide rough order of magnitude cost estimates for facility development and test operations. The options can be divided into two distinct schemes; (1) real-time filtering of the engine exhaust and its release to the environment or (2) capture and storage of engine exhaust for subsequent processing.

  4. Beam test of novel n-in-p strip sensors for high radiation environment

    Science.gov (United States)

    Kubota, T.; Kishida, T.; Jinnouchi, O.; Ikegami, Y.; Unno, Y.; Terada, S.; Mitsui, S.; Tamii, A.; Aoi, T.; Hanagaki, K.; Hara, K.; Kimura, N.; Takashima, R.; Takubo, Y.; Tojo, J.; Nagai, K.; Nakano, I.; Yorita, K.

    2013-12-01

    Highly radiation tolerant n-in-p strip sensors have been developed for the high-luminosity LHC (HL-LHC). This paper reports the results of measurements with 392 MeV kinetic energy proton beam at RCNP in December 2011. The data was taken with a new DAQ system consisting of an universal read-out board ‘SEABAS’ and beam tracking telescopes whose spacial resolution is better than 5 μm. The aim of this beam test is to evaluate the new 1 cm×1 cm n-in-p miniature sensors before and after 1015 neq cm-2 irradiation. The median charge of un-irradiated sensor is 6.2 fC at full depletion voltage, while the median charge after 1015 neq cm-2 irradiation of the sensor is 4.2 fC. The novel Punch-Through-Protection (PTP) has been implemented in these sensors. The length of active region of the sensor around PTP is observed to be decreased by 12 μm in the irradiated sensors at 1015 neq cm-2.

  5. A fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection.

    Science.gov (United States)

    Di Nardo, F; Anfossi, L; Giovannoli, C; Passini, C; Goftman, V V; Goryacheva, I Y; Baggiani, C

    2016-04-01

    A fluorescent immunochromatographic strip test (ICST) based on the use of Quantum Dots (QD) was developed and applied to detect fumonisins in maize samples. A limit of detection for fumonisin B1 of 2.8 µg L(-1) was achieved, with an analytical working range of 3-350 µg L(-1), corresponding to 30-3500 µg kg(-1) in maize flour samples, according with the extraction procedure. The time required to perform the analysis was 22 min, including sample preparation. Recovery values in the range from 91.4% to 105.4% with coefficients of variation not exceeding 5% were obtained for fortified and naturally contaminated maize flour samples. To evaluate the possible improvements due to the use of QD for ICST technology, we performed a direct comparison of the proposed QD-ICST to a gold nanoparticles- and a chemiluminescent-ICST previously developed for fumonisins detection, in which the same immunoreagents were employed. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Used fuel rail shock and vibration testing options analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Steven B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Best, Ralph E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Klymyshyn, Nicholas A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jensen, Philip J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Maheras, Steven J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-09-25

    The objective of the rail shock and vibration tests is to complete the framework needed to quantify loads of fuel assembly components that are necessary to guide materials research and establish a technical basis for review organizations such as the U.S. Nuclear Regulatory Commission (NRC). A significant body of experimental and numerical modeling data exists to quantify loads and failure limits applicable to normal conditions of transport (NCT) rail transport, but the data are based on assumptions that can only be verified through experimental testing. The test options presented in this report represent possible paths for acquiring the data that are needed to confirm the assumptions of previous work, validate modeling methods that will be needed for evaluating transported fuel on a case-by-case basis, and inform material test campaigns on the anticipated range of fuel loading. The ultimate goal of this testing is to close all of the existing knowledge gaps related to the loading of used fuel under NCT conditions and inform the experiments and analysis program on specific endpoints for their research. The options include tests that would use an actual railcar, surrogate assemblies, and real or simulated rail transportation casks. The railcar carrying the cradle, cask, and surrogate fuel assembly payload would be moved in a train operating over rail track modified or selected to impart shock and vibration forces that occur during normal rail transportation. Computer modeling would be used to help design surrogates that may be needed for a rail cask, a cask’s internal basket, and a transport cradle. The objective of the design of surrogate components would be to provide a test platform that effectively simulates responses to rail shock and vibration loads that would be exhibited by state-of-the-art rail cask, basket, and/or cradle structures. The computer models would also be used to help determine the placement of instrumentation (accelerometers and strain gauges

  7. Versatile Strip Seed Drill: A 2-Wheel Tractor-Based Option for Smallholders to Implement Conservation Agriculture in Asia and Africa

    Directory of Open Access Journals (Sweden)

    Md. Enamul Haque

    2016-01-01

    Full Text Available Smallholders in Asia and Africa require low-cost seed drills for minimal soil disturbance while establishing various crops. A seed drill that can be drawn by the widely-available two-wheel tractor (2WT is an attractive option for mechanization of no-till in small-sized fields. The Versatile Strip Seed Drill (VSSD was designed with the capacity to make up to 40 mm wide and 60 mm deep strips in untilled land along with seed and basal fertilizer application in a single-pass operation, while powered by the 8.95 to 11.93 kW 2WT. An important innovation of the VSSD was to fit the seed box with both fluted roller-type seed meters for delivery of sufficient small-size seeds to achieve adequate plant density per unit row length; and vertical disk-type seed meters for precision and spaced row planting of larger seeds. Both incessant seed dropping by fluted roller seed meters and spaced planting by vertical disk type seed meters provided optimum plant populations that were generally higher than in conventional, full-tillage plots with the same rate of hand broadcasted seed and fertilizers. Time required for crop establishment by VSSD ranged from 0.13 to 0.18 ha·h−1. When the VSSD was attached to the 2WT for crop establishment, the diesel fuel consumption varied from 4.4 to 6.1 L·ha−1, which was lower than for most 2WT-based planters previously used in Bangladesh. In on-farm multi-locations trials, wheat crops established with the VSSD had statistically similar grain yield compared to conventional tillage; however, significantly higher grain yield was obtained from mustard and lentil, by 14% and 19%, respectively. The VSSD is a unique, minimum-soil-disturbance multi-crop planter, and can be a platform on which to build conservation agriculture systems for small farms in Asia and Africa.

  8. Assembly and Electrical Tests of the First Full-size Forward Module for the ATLAS ITk Strip Detector

    CERN Document Server

    Garcia-Argos, Carlos; The ATLAS collaboration

    2018-01-01

    The ATLAS experiment will replace the existing Inner Detector by an all-silicon detector named the Inner Tracker (ITk) for the High Luminosity LHC upgrades. In the outer region of the Inner Tracker is the strip detector, which consists of a four layer barrel and six discs to each side of the barrel, with silicon-strip modules as basic units. Each module is composed of a sensor and one or more flex circuits that hold the read-out electronics. In the experiment, the modules are mounted on support structures with integrated power and cooling. The modules are designed with geometries that accommodate the central and forward regions, with rectangular sensors in the barrels and wedge shaped sensors in the end-caps. The strips lengths and pitch sizes vary according to the occupancy of the region. In this contribution, we present the construction and results of the electrical tests of the first full-size module of the innermost forward region, named \\textit{Ring 0} in the ATLAS ITk strip detector nomenclature. This m...

  9. Assembly and Electrical Tests of the First Full-size Forward Module for the ATLAS ITk Strip Detector

    CERN Document Server

    Garcia-Argos, Carlos; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment will replace the existing Inner Detector by an all-silicon detector named the Inner Tracker (ITk) for the High Luminosity LHC upgrades. In the outer region of the Inner Tracker is the strip detector, which consists of a four layer barrel and six discs to each side of the barrel, with silicon-strip modules as basic units. Each module is composed of a sensor and one or more flex circuits that hold the read-out electronics. In the experiment, the modules are mounted on support structures with integrated power and cooling. The modules are designed with geometries that accommodate the central and forward regions, with rectangular sensors in the barrels and wedge shaped sensors in the end-caps. The strips lengths and pitch sizes vary according to the occupancy of the region. In this contribution, we present the construction and the results of the electrical tests of the first full-size module of the innermost forward region, named Ring 0 in the ATLAS ITk strip detector nomenclature. This module...

  10. New testing options for diagnosing and grading dry eye disease.

    Science.gov (United States)

    Foulks, Gary N; Pflugfelder, Stephen C

    2014-06-01

    To describe new options for diagnosis and severity grading of dry eye disease. Perspective on technological advancements to identify tear dysfunction and their value in diagnosing and grading dry eye disease. Evidence is presented on new and evolving technologies to measure tear stability, composition, and meniscus height and their role in dry eye diagnosis and therapeutic efficacy grading is assessed. Evolving concepts regarding pathogenesis and new technologies to evaluate the tears and ocular surface have improved the ability to diagnose, classify, and grade the severity of dry eye disease. New technologies include noninvasive imaging of tear stability and tear meniscus height as a measure of tear volume and tear composition (osmolarity, lacrimal factors, inflammatory mediators, growth and differentiation factors). Approved tests, such as tear osmolarity and tear imaging, are being integrated into clinical practice and may eventually supplant certain traditional tests that have greater variability and less sensitivity. Other tests, such as molecular assays of tears and conjunctival cells, are currently being used in studies investigating pathogenesis and therapeutic mechanism of action. They may eventually translate to routine clinical practice. New technologies have emerged that can noninvasively evaluate the tears and measure disease-associated compositional changes. These tests are being integrated into clinical practice and therapeutic trials for diagnosis, classification, and severity grading of dry eye disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhexiang; Wang, Jun; Wang, Hua; Li, Yao Q.; Lin, Yuehe

    2012-05-30

    A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population

  12. Reception Test of Petals for the End Cap TEC+ of the CMS Silicon Strip Tracker

    CERN Document Server

    Bremer, R; Klein, Katja; Schmitz, Stefan Antonius; Adler, Volker; Adolphi, Roman; Ageron, Michel; Agram, Jean-Laurent; Atz, Bernd; Barvich, Tobias; Baulieu, Guillaume; Beaumont, Willem; Beissel, Franz; Bergauer, Thomas; Berst, Jean-Daniel; Blüm, Peter; Bock, E; Bogelsbacher, F; de Boer, Wim; Bonnet, Jean-Luc; Bonnevaux, Alain; Boudoul, Gaelle; Bouhali, Othmane; Braunschweig, Wolfgang; Brom, Jean-Marie; Butz, Erik; Chabanat, Eric; Chabert, Eric Christian; Clerbaux, Barbara; Contardo, Didier; De Callatay, Bernard; Dehm, Philip; Delaere, Christophe; Della Negra, Rodolphe; Dewulf, Jean-Paul; D'Hondt, Jorgen; Didierjean, Francois; Dierlamm, Alexander; Dirkes, Guido; Dragicevic, Marko; Drouhin, Frédéric; Ernenwein, Jean-Pierre; Esser, Hans; Estre, Nicolas; Fahrer, Manuel; Fernández, J; Florins, Benoit; Flossdorf, Alexander; Flucke, Gero; Flügge, Günter; Fontaine, Jean-Charles; Freudenreich, Klaus; Frey, Martin; Friedl, Markus; Furgeri, Alexander; Giraud, Noël; Goerlach, Ulrich; Goorens, Robert; Graehling, Philippe; Grégoire, Ghislain; Gregoriev, E; Gross, Laurent; Hansel, S; Haroutunian, Roger; Hartmann, Frank; Heier, Stefan; Hermanns, Thomas; Heydhausen, Dirk; Heyninck, Jan; Hosselet, J; Hrubec, Josef; Jahn, Dieter; Juillot, Pierre; Kaminski, Jochen; Karpinski, Waclaw; Kaussen, Gordon; Keutgen, Thomas; Klanner, Robert; König, Stefan; Kosbow, M; Krammer, Manfred; Ledermann, Bernhard; Lemaître, Vincent; De Lentdecker, Gilles; Linn, Alexander; Lounis, Abdenour; Lübelsmeyer, Klaus; Lumb, Nicholas; Maazouzi, Chaker; Mahmoud, Tariq; Michotte, Daniel; Militaru, Otilia; Mirabito, Laurent; Müller, Thomas; Neukermans, Lionel; Ollivetto, C; Olzem, Jan; Ostapchuk, Andrey; Pandoulas, Demetrios; Pein, Uwe; Pernicka, Manfred; Perriès, Stephane; Piaseki, C; Pierschel, Gerhard; Piotrzkowski, Krzysztof; Poettgens, Michael; Pooth, Oliver; Rouby, Xavier; Sabellek, Andreas; Schael, Stefan; Schirm, Norbert; Schleper, Peter; Schultz von Dratzig, Arndt; Siedling, Rolf; Simonis, Hans-Jürgen; Stahl, Achim; Steck, Pia; Steinbruck, G; Stoye, Markus; Strub, Roger; Tavernier, Stefaan; Teyssier, Daniel; Theel, Andreas; Trocmé, Benjamin; Udo, Fred; Van der Donckt, M; Van der Velde, C; Van Hove, Pierre; Vanlaer, Pascal; Van Lancker, Luc; Van Staa, Rolf; Vanzetto, Sylvain; Weber, Markus; Weiler, Thomas; Weseler, Siegfried; Wickens, John; Wittmer, Bruno; Wlochal, Michael; De Wolf, Eddi A; Zhukov, Valery; Zoeller, Marc Henning

    2009-01-01

    The silicon strip tracker of the CMS experiment has been completed and was inserted into the CMS detector in late 2007. The largest sub system of the tracker are its end caps, comprising two large end caps (TEC) each containing 3200 silicon strip modules. To ease construction, the end caps feature a modular design: groups of about 20 silicon modules are placed on sub-assemblies called petals and these self-contained elements are then mounted onto the TEC support structures. Each end cap consists of 144 such petals, which were built and fully qualified by several institutes across Europe. From

  13. Development of a one-step immunochromatographic strip test for the detection of sennosides A and B.

    Science.gov (United States)

    Putalun, Waraporn; Morinaga, Osamu; Tanaka, Hiroyuki; Shoyama, Yukihiro

    2004-01-01

    An immunochromatographic strip test was developed to detect sennoside A (1) and sennoside B (2) using anti-1 and anti-2 monoclonal antibodies. The qualitative assay was based on a competitive immunoassay in which the detector reagent consisted of colloidal gold particles coated with the respective sennoside antibodies. The capture reagents were 1- and 2-human serum albumin (HSA) conjugates immobilised on a nitrocellulose membrane on the test strip. The sample containing 1 and 2, together with detector reagent, passed over the zone where the capture reagents had been immobilised. The analytes in the sample competed for binding to the limited amount of antibodies in the detector reagent with the immobilised 1- and 2-HSA conjugates on the membrane and hence positive samples showed no colour in the capture spot zone. Detection limits for the strip test were 125 ng/mL for both sennosides. The assay system is useful as a rapid and simple screening method for the detection of 1 and 2 in plants, drugs and body fluids.

  14. The frequentist implications of optional stopping on Bayesian hypothesis tests.

    Science.gov (United States)

    Sanborn, Adam N; Hills, Thomas T

    2014-04-01

    Null hypothesis significance testing (NHST) is the most commonly used statistical methodology in psychology. The probability of achieving a value as extreme or more extreme than the statistic obtained from the data is evaluated, and if it is low enough, the null hypothesis is rejected. However, because common experimental practice often clashes with the assumptions underlying NHST, these calculated probabilities are often incorrect. Most commonly, experimenters use tests that assume that sample sizes are fixed in advance of data collection but then use the data to determine when to stop; in the limit, experimenters can use data monitoring to guarantee that the null hypothesis will be rejected. Bayesian hypothesis testing (BHT) provides a solution to these ills because the stopping rule used is irrelevant to the calculation of a Bayes factor. In addition, there are strong mathematical guarantees on the frequentist properties of BHT that are comforting for researchers concerned that stopping rules could influence the Bayes factors produced. Here, we show that these guaranteed bounds have limited scope and often do not apply in psychological research. Specifically, we quantitatively demonstrate the impact of optional stopping on the resulting Bayes factors in two common situations: (1) when the truth is a combination of the hypotheses, such as in a heterogeneous population, and (2) when a hypothesis is composite-taking multiple parameter values-such as the alternative hypothesis in a t-test. We found that, for these situations, while the Bayesian interpretation remains correct regardless of the stopping rule used, the choice of stopping rule can, in some situations, greatly increase the chance of experimenters finding evidence in the direction they desire. We suggest ways to control these frequentist implications of stopping rules on BHT.

  15. Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter

    CERN Document Server

    Auffray, Etiennette; Barney, D; Bassompierre, Gabriel; Benhammou, Ya; Blick, A M; Bloch, P; Bonamy, P; Bourotte, J; Buiron, L; Cavallari, F; Chipaux, Rémi; Cockerill, D J A; Dafinei, I; Davies, G; Depasse, P; Deiters, K; Diemoz, M; Dobrzynski, Ludwik; Donskov, S V; Mamouni, H E; Ercoli, C; Faure, J L; Felcini, Marta; Gautheron, F; Géléoc, M; Givernaud, Alain; Gninenko, S N; Godinovic, N; Graham, D J; Guillaud, J P; Guschin, E; Haguenauer, Maurice; Hillemanns, H; Hofer, H; Ille, B; Inyakin, A V; Jääskeläinen, S; Katchanov, V A; Kirn, T; Kloukinas, Kostas C; Korzhik, M V; Lassila-Perini, K M; Lebrun, P; Lecoq, P; Lecoeur, Gérard; Lecomte, P; Leonardi, E; Locci, E; Loos, R; Longo, E; MacKay, C K; Martin, E; Mendiburu, J P; Musienko, Yu V; Nédélec, P; Nessi-Tedaldi, F; Organtini, G; Paoletti, S; Pansart, J P; Peigneux, J P; Puljak, I; Qian, S; Reid, E; Renker, D; Rosowsky, A; Rosso, E; Rusack, R W; Rykaczewski, H; Schneegans, M; Seez, Christopher J; Semeniouk, I N; Shagin, P M; Sillou, D; Singovsky, A V; Sougonyaev, V; Soric, I; Verrecchia, P; Vialle, J P; Virdee, Tejinder S; Zhu, R Y

    1998-01-01

    Tests of lead tungstate crystal matrices carried out in high-energy electron beams in 1996, using new crystals, new APDs and an improved test set-up, confirm that an energy resolution of better than 0 .6% at 100 GeV can be obtained when the longitudinal uniformity of the struck crystal is adequate. Light loss measurements under low dose irradiation are reported. It is shown that there is no loss of energy resolution after irradiation and that the calibration change due to light loss can be tracked with a precision monitoring system. Finally, successuful tests with a preshower device, equipped wi th silicon strip detector readout, are described.

  16. Total protein concentration and diagnostic test results for gray wolf (Canis lupus) serum using Nobuto filter paper strips

    Science.gov (United States)

    Jara, Rocio F.; Sepúlveda, Carolina; Ip, Hon S.; Samuel, Michael D.

    2015-01-01

    Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.

  17. Novel cellulose-based halochromic test strips for naked-eye detection of alkaline vapors and analytes.

    Science.gov (United States)

    Abou-Yousef, Hussein; Khattab, Tawfik A; Youssef, Yehia A; Al-Balakocy, Naser; Kamel, Samir

    2017-08-01

    A simple, portable and highly sensitive naked-eye test strip is successfully prepared for optical detection of gaseous and aqueous alkaline analytes. Novel pH-sensory tricyanofuran-hydrazone (TCFH) disperse colorant containing a hydrazone recognition functional moiety is successfully synthesized via azo-coupling reaction between active methyl-containing tricyanofuran (TCF) heterocycle and diazonium salt of 4-aminobenzaldehyde followed by Knoevenagel condensation with malononitrile. UV-vis absorption spectra display solvatochromism and reversible color changes of the TCFH solution in dimethyl sulfoxide in response to pH variations. We investigate the preparation of hydrophobic cellulose/polyethylene terephthalate composites characterized by their high affinity for disperse dyes. Composite films made from CA, Cell/CA, PET/CA, and Cell/PET-CA are produced via solvent-casting procedure using 10-30% modified cellulose or modified polyethylene terephthalate. The mechanical properties and morphologies of these composite films are investigated. The prepared pH-sensory hydrazone-based disperse dye is then applied to dye the produced cellulose-based composite films employing the high temperature pressure dyeing procedure. The produced halochromic PET-CA-TCFH test strip provide an instant visible signal from orange to purple upon exposure to alkaline conditions as proved by the coloration measurements. The sensor strip exhibits high sensitivity and quick detection toward ammonia in both of aqueous and vapor phases by naked-eye observations at room temperature and atmospheric pressure. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Test of supersymmetry in the 193Ir→194Pt proton stripping reactions

    International Nuclear Information System (INIS)

    Vergnes, M.; Rotbard, G.; Kalifa, J.; Berrier-Ronsin, G.; Vernotte, J.; Seltz, R.; Burke, D.G.

    1980-01-01

    A breakdown of the selection rules of the supersymmetry model is observed for the population of the 0 2 + and 2 2 + levels of 194 Pt in the 193 Ir → 194 Pt proton stripping reactions performed using the Orsay and Mc Master University tandem accelerators. The existence of other violations in the neighbouring nuclei leads to believe that we are seeing the limitations of the supersymmetry scheme itself, at least for particle transfer reactions

  19. Construction, test and operation in a high intensity beam of a small system of micro-strip gas chambers

    Science.gov (United States)

    Barr, A.; Bachmann, S.; Boimska, B.; Bouclier, R.; Braem, A.; Camps, C.; Capeáns, M.; Commichau, V.; Dominik, W.; Flügge, G.; Gómez, F.; Hammarstrom, R.; Hangarter, K.; Hoch, M.; Labbé, J. C.; Macke, D.; Manzin, G.; Meijers, F.; Million, G.; Muhlemann, K.; Nagaslaev, V.; Peisert, A.; Ropelewski, L.; Runolfsson, O.; Sauli, F.; Schulte, R.; Schulz, M.; Sharma, A.; Shekhtman, L.; Wolff, C.

    1998-02-01

    We describe the construction, test and installation procedures, and the experience gained with the operation of a small but complete system of high-rate Micro-Strip Gas Chambers, made on thin borosilicate glass with a diamond-like coating with chromium or gold strips. A set of detectors, fully equipped with read-out electronics and each with an active area of 100 × 100 mm 2, was exposed during six months to a high-intensity muon beam at CERN with a peak intensity of ˜ 10 4 mm -2s -1. Continuous monitoring of the performance of the chambers during the beam runs allowed the evaluation of detection efficiency and the monitoring of accidental rates, as well as the study of ambient induced variations and aging in realistic beam conditions. No significant difference has been found in the operation of under-and over-coated plates. Efficiencies could reach ˜ 98% in best operating conditions, although local lower values were often observed due to missing channels (open strips, broken bonds and dead electronic channels). The long-term operation of the chambers has been more difficult than expected, with the appearance of break-downs and loss of efficiency in some detectors, possibly induced by the presence of small gas leaks, to water permeation or to residual reactivity of the quencher gas (dimethylether).

  20. Current Ground Test Options for Nuclear Thermal Propulsion (NTP)

    Science.gov (United States)

    Gerrish, Harold P., Jr.

    2014-01-01

    (approximately 1 GW) with a maximum burn time of 1 hour. The concept utilized lessons learned from NF-1. The strategy breaks down the exhaust into parallel paths to allow flexibility with engine size and mass flow of exhaust. Similar to NF-1, the exhaust is slowed down, cooled, filtered of particulates, filtered of noble gases, and then the clean hydrogen is flared to open air. Another concept proposed by Steve Howe (currently Director of the Center for Space Nuclear Research) to simplify the NTP exhaust filtering is to run the hydrogen exhaust into boreholes underground to filter the exhaust. The two borehole site locations proposed are at the NTS and at the Idaho National Laboratory (INL). At NTS, the boreholes are 8' diameter and 1200' deep. The permeability of hydrogen through the soil and its buoyancy will allow it to rise up through the soil and allow the filtering of noble gases and radioactive particulates. The exhaust needs to be cooled to 600C before entering the borehole to avoid soil glazing. Preliminary analysis shows a small buildup of back pressure with time which depends on permeability. Noble gases entering the borehole walls deep can take a long time before reaching the surface. Other factors affecting permeability include borehole pressure, water saturation, and turbulence. Also, a possible need to pump out contaminated water collected at the bottom of the borehole. At INL, the borehole concept is slightly different. The underground borehole has openings to the soil at special depths which have impermeable interbeds above the water table and below the surface to allow the exhaust to travel horizontal between the impermeable layers. Preliminary results indicate better permeability than at NTS. The last option is total containment of the exhaust during the test run. The concept involves slowing down the flow to subsonic in a water cooled diffuser. The hydrogen is burned off in an oxygen rich afterburner with the only products being steam, oxygen, and some noble

  1. Extraction, -scrub, -strip test results from the interim salt disposition program macrobatch 10 tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-26

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). The Salt Batch 10 characterization results were previously reported.ii,iii An Extraction, -Scrub, -Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the NGS Blend solvent currently being used at the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 110. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This is better than the predicted value of 39.8 from a recently created D(Cs) model.

  2. Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.

    Science.gov (United States)

    Rota, Cristina; Biondi, Marco; Trenti, Tommaso

    2011-09-26

    Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine determination. The two instruments have demonstrated comparable performances: precision and correlation between instruments and strips, evaluated for chemical-physical parameters, were always good. Furthermore, accuracy was always very good: results of protein and glucose semi-quantitative measurements resulted to be highly correlated with those obtained by quantitative methods. Moreover, the semi-quantitative measurements of creatinine, employing Aution Sticks 10PA urine strips, were highly comparable with quantitative results. 10PA urine strips are eligible for urine creatinine determination with the possibility of correcting urinalysis results for urinary creatinine concentration, whenever necessary and calculating the protein creatinine ratio. Further studies should be carried out to evaluate effectiveness and appropriateness of the usage of creatinine semi-quantitative analysis.

  3. In Vivo Cosmetic Product Efficacy Testing by Analyzing Epidermal Proteins Extracted from Tape Strips

    Directory of Open Access Journals (Sweden)

    Marie Westman

    2014-02-01

    Full Text Available The objective of this in vivo pilot study was to investigate whether differential biomarker analysis from skin tape strips could be used, not only to evaluate the difference between treated and untreated skin, but also to evaluate the effect of different product treatments. Ten volunteers were included in the study, applying two different basic formulations on their forearms. After four weeks of product application, and also after one week of treatment remission, tape strips were collected from the different treatment sites, as well as from untreated skin. The biomarkers investigated were selected to cover different aspects of epidermal differentiation and in connection with moisturization and barrier function. Levels of Involucrin were increased in both treatments, compared to untreated skin, whereas the levels of Keratin-6 were decreased for both treatments. In addition, a pattern for increased levels of Hornerin and Claudin-1 was also detected. There were no significant differences between the two treatments, only for treatment compared to untreated, but there were tendencies for different effect on some of the biomarkers investigated, differences that may reach significance with increased sample size. The major differences between the two treatments in this study were seen after one week of product remission, although due to too small sample size these differences were not significant.

  4. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed

    Directory of Open Access Journals (Sweden)

    Wang ZZ

    2014-04-01

    Full Text Available Zhizeng Wang,1 Dejuan Zhi,2 Yang Zhao,1 Hailong Zhang,2 Xin Wang,2 Yi Ru,1 Hongyu Li1,2 1MOE Key Laboratory of Cell Activities and Stress Adaptations, School of Life Sciences, Lanzhou University, Lanzhou, People's Republic of China; 2Institute of Microbiology and Biochemical Pharmacy, School of Pharmaceutics, Lanzhou University, Lanzhou, People's Republic of China Abstract: Although high melamine (MEL intake has been proven to cause serious health problems, MEL is sometimes illegally added to milk products and animal feed, arousing serious food safety concerns. A satisfactory method of detecting MEL in onsite or in-home testing is in urgent need of development. This work aimed to explore a rapid, convenient, and cost-effective method of identifying MEL in milk products or other food by colloidal selenium-based lateral flow immunoassay. Colloidal selenium was synthesized by L-ascorbic acid to reduce seleninic acid at room temperature. After conjugation with a monoclonal antibody anti-MEL, a test strip was successfully prepared. The detection limit of the test strip reached 150 µg/kg, 1,000 µg/kg, and 800 µg/kg in liquid milk, milk powder, and animal feed, respectively. No cross-reactions with homologues cyanuric acid, cyanurodiamide, or ammelide were found. Moreover, the MEL test strip can remain stable after storage for 1 year at room temperature. Our results demonstrate that the colloidal selenium MEL test strip can detect MEL in adulterated milk products or animal feed conveniently, rapidly, and sensitively. In contrast with a colloidal gold MEL test strip, the colloidal selenium MEL test strip was easy to prepare and more cost-efficient. Keywords: melamine, selenium nanoparticles, test strip, milk, animal feed, dairy food

  5. The Honeycomb Strip Chamber

    International Nuclear Information System (INIS)

    Graaf, Harry van der; Buskens, Joop; Rewiersma, Paul; Koenig, Adriaan; Wijnen, Thei

    1991-06-01

    The Honeycomb Strip Chamber (HSC) is a new position sensitive detector. It consists of a stack of folded foils, forming a rigid honeycomb structure. In the centre of each hexagonal cell a wire is strung. Conducting strips on the foils, perpendicular to the wires, pick up the induced avalanche charge. Test results of a prototype show that processing the signals form three adjacent strips nearest to the track gives a spatial resolution better than 64 μm for perpendicular incident tracks. The chamber performance is only slightly affected by a magnetic field. (author). 25 refs.; 21 figs

  6. Simultaneous quantitative detection of multiple tumor markers with a rapid and sensitive multicolor quantum dots based immunochromatographic test strip.

    Science.gov (United States)

    Wang, Chunying; Hou, Fei; Ma, Yicai

    2015-06-15

    A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 μL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Simultaneous detection of dual biomarkers from humans exposed to organophosphorus pesticides by combination of immunochromatographic test strip and ellman assay.

    Science.gov (United States)

    Yang, Mingming; Zhao, Yuting; Wang, Limin; Paulsen, Michael; Simpson, Christopher D; Liu, Fengquan; Du, Dan; Lin, Yuehe

    2018-05-01

    A novel sandwich immunoassay based immunochromatographic test strip (ICTS) has been developed for simultaneously measuring both butyrylcholinesterase (BChE) activity and the total amount of BChE (including inhibited and active enzyme) from 70 μLpost-exposure human plasma sample. The principle of this method is based on the BChE monoclonal antibody (MAb) capable of acting as both capture antibody and detection antibody. The BChE MAb which was immobilized on the test line was able to recognize both organophosphorus BChE adducts (OP-BChE) and BChE and provided equal binding affinity, permitting detection of the total enzyme amount in post-exposure human plasma samples. The formed immunocomplexes on the test line can further be excised from the test-strip for subsequent off-line measurement of BChE activity using the Ellman assay. Therefore, dual biomarkers of BChE activity and phosphorylation (OP-BChE) will be obtained simultaneously. The whole sandwich-immunoassay was performed on one ICTS, greatly reducing analytical time. The ICTS sensor showed excellent linear responses for assaying total amount of BChE and active BChE ranging from 0.22 to 3.58nM and 0.22-7.17nM, respectively. Both the signal detection limits are 0.10nM. We validated the practical application of the proposed method to measure 124 human plasma samples from orchard workers and cotton farmers with long-term exposure to organophosphorus pesticides (OPs). The results were in highly agreement with LC/MS/MS which verified our method is extremely accurate. Combining the portability and rapidity of test strip and the compatibility of BChE MAb as both capture antibody and detection antibody, the developed method provides a baseline-free, low-cost and rapid tool for in-field monitoring of OP exposures. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. A feasibility study on different NDT techniques used for testing bond quality in cold roll bonded Al-Sn alloy/steel bimetal strips

    Directory of Open Access Journals (Sweden)

    Tallafuss Philipp Johannes

    2017-01-01

    Full Text Available This paper presents non-destructive testing (NDT results for the detection of bond defects in aluminium-tin (Al-Sn alloy/steel bimetal strips. Among all types of bimetal strip that are used in the automotive industry for plain journal engine bearings, Al-Sn alloys cold roll bonded (CRB onto steel backing is the most common type. The difficulty to evaluate the metallurgical bond between the two dissimilar metals is a major industrial concern, which comprises the risk that bearings fail in the field. Considering the harsh performance requirements, 100% online non-destructive testing would be desirable to significantly reduce the business risk. Nowadays bimetal strip manufacturers still rely on destructive testing through different peel-off tests. This work offers the results from four independent NDT studies, using active thermography, shearography, ultrasound and guided wave electromagnetic acoustic transducers (EMATs and samples with different artificially implanted defects, to explore the feasibility to qualitatively indicate the occurrence of bond defects. A destructive peel off test was used to correlate the NDT results with known bond quality. The studies were done under laboratory conditions, and in case of ultrasound also online under production conditions. During the ultrasound online test, the requirements that a NDT technique has to fulfil for online inspection of Al-Sn alloy/steel bimetal strip were established. For active thermography, shearography and guided wave EMAT techniques, it was theoretically analysed, if the laboratory test results could be transferred to testing under production conditions. As a result, guided waves using EMATs, among the four tested methods, are best suited for online inspection of Al-Sn alloy/steel bimetal strip. This research was carried out in collaboration with MAHLE Engine Systems UK Ltd., an Al-Sn alloy/steel bimetal strip manufacturer for the automotive industry.

  9. Engineered Option Treatment of Remediated Nitrate Salts: Surrogate Batch-Blending Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from batch-blending test work for remediated nitrate salt (RNS) treatment. Batch blending was identified as a preferred option for blending RNS and unremediated nitrate salt (UNS) material with zeolite to effectively safe the salt/Swheat material identified as ignitable (U.S. Environmental Protection Agency code D001). Blending with zeolite was the preferred remediation option identified in the Options Assessment Report and was originally proposed as the best option for remediation by Clark and Funk in their report, Chemical Reactivity and Recommended Remediation Strategy for Los Alamos Remediated Nitrate Salt (RNS) Wastes, and also found to be a preferred option in the Engineering Options Assessment Report: Nitrate Salt Waste Stream Processing. This test work evaluated equipment and recipe alternatives to achieve effective blending of surrogate waste with zeolite.

  10. Feasibility, cost and safety of some rehabilitation options for the Maralinga test site

    International Nuclear Information System (INIS)

    Vande Putte, D.; Tufton, E.P.S.; Myall, M.

    1992-01-01

    The need to rehabilitate the former nuclear test site at Maralinga has required the development of safe and cost-effective clean-up measures. Options have been investigated, which include fencing-off parts of the site, removing surface soil, mixing surface soil and stabilising the contents of debris pits. The results of the study can be used in selecting the most suitable options or combination of options necessary to achieve a given radiological end-point. (author)

  11. System tests with silicon strip module prototypes for the Phase-2-upgrade of the CMS tracker

    Energy Technology Data Exchange (ETDEWEB)

    Feld, Lutz; Karpinski, Waclaw; Klein, Katja; Preuten, Marius [I. Physikalisches Institut B, RWTH Aachen University (Germany)

    2016-07-01

    To prepare the CMS experiment for the High Luminosity LHC and its instantaneous luminosity of 5 . 10{sup 34} cm{sup -2}s{sup -1}, in the Long Shutdown 3 (around 2024) the CMS Silicon Tracker will be replaced. The Silicon Strip Modules for the new Tracker will host two vertically stacked sensors. The combination of hit information from both sensors will allow the estimation of the transverse momentum (p{sub T}) of charged particles in the module front-end. This can be used to identify hits from potential interesting high-p{sub T} tracks (above 2 GeV) for the first trigger level. The CMS Binary Chip (CBC) provides the analogue readout of two sensors and a digital section, into which the momentum discrimination is integrated. The modules will host a new DC-DC converter chain, which will allow individual powering of each module. First measurements with early prototypes on the interplay between DC-DC powering and the read-out functions of the module are presented in this talk.

  12. Charpy impact test of oxidized and hydrogenated zircaloy using a thin strip specimen

    International Nuclear Information System (INIS)

    Otsuka, Teppei; Hashizume, Kenichi; Sugisaki, Masayasu

    2004-01-01

    The impact properties of an oxidized and a hydrogenated Zircaloy have been studied with an instrumented Charpy machine by using a strip Charpy V-notch specimen (1 mm thick by 4mm wide). Fracture processes such as crack initiation and propagation were examined using load-displacement curves obtained in this study. In the case of the hydrogenated specimen containing preferentially oriented hydrides, an appreciable decrease in the absorbed energy was observed in the crack propagation rather than in the crack initiation. From results of fractographs of the specimen, it was suggested that the reduction of the crack propagation energy of hydrogenated specimen could be attributed to the change of the stress state in the Zircaloy matrix, which was caused by the fracture of hydride in the inner part of specimen. In the case of the specimen oxidized at 973k for 60 min, on which an oxide layer (4 μm in thickness) and oxygen incursion layer (4μm) were formed, the surface layers affected the crack initiation process. The growing oxygen incursion layer, in particular, resulted in the constraint of plastic deformation of the Zircaloy matrix not only in the crack initiation but also in the crack propagation as its thickness increased. (author)

  13. Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents

    Energy Technology Data Exchange (ETDEWEB)

    Du, Dan; Wang, Jun; Wang, Limin; Lu, Donglai; Lin, Yuehe

    2012-02-08

    An integrated lateral flow test strip with electrochemical sensor (LFTSES) device with rapid, selective and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of post-exposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with detection limit of 0.02 nM. Based on this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values, but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.

  14. 40 CFR 158.510 - Tiered testing options for nonfood pesticides.

    Science.gov (United States)

    2010-07-01

    ... pesticides. 158.510 Section 158.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Toxicology § 158.510 Tiered testing options for nonfood pesticides. For nonfood use pesticides only, applicants have two options for generating and submitting...

  15. New Options for Usability Testing Projects in Business Communication Courses

    Science.gov (United States)

    Jameson, Daphne A.

    2013-01-01

    The increasing availability of recording technologies makes it easier to include usability testing projects in business communication courses. Usability testing is a method of discovering whether people can navigate, read, and understand a print or electronic communication well enough to achieve a particular purpose in a reasonable time frame.…

  16. All of the above: When multiple correct response options enhance the testing effect.

    Science.gov (United States)

    Bishara, Anthony J; Lanzo, Lauren A

    2015-01-01

    Previous research has shown that multiple choice tests often improve memory retention. However, the presence of incorrect lures often attenuates this memory benefit. The current research examined the effects of "all of the above" (AOTA) options. When such options are correct, no incorrect lures are present. In the first three experiments, a correct AOTA option on an initial test led to a larger memory benefit than no test and standard multiple choice test conditions. The benefits of a correct AOTA option occurred even without feedback on the initial test; for both 5-minute and 48-hour retention delays; and for both cued recall and multiple choice final test formats. In the final experiment, an AOTA question led to better memory retention than did a control condition that had identical timing and exposure to response options. However, the benefits relative to this control condition were similar regardless of the type of multiple choice test (AOTA or not). Results suggest that retrieval contributes to multiple choice testing effects. However, the extra testing effect from a correct AOTA option, rather than being due to more retrieval, might be due simply to more exposure to correct information.

  17. Oxygen Containment System Options for Nuclear Thermal Propulsion Testing

    Data.gov (United States)

    National Aeronautics and Space Administration — All nuclear thermal propulsion (NTP) ground testing conducted in the 1950s and 1960s during the ROVER/(Nuclear Engine Rocket Vehicle Application (NERVA) program...

  18. Standard Waste Box Lid Screw Removal Option Testing

    International Nuclear Information System (INIS)

    Anast, Kurt Roy

    2016-01-01

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  19. Standard Waste Box Lid Screw Removal Option Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  20. Development of paper-based color test-strip for drug detection in aquatic environment: Application to oxytetracycline.

    Science.gov (United States)

    Gomes, Helena I A S; Sales, M Goreti F

    2015-03-15

    The wide use of antibiotics in aquaculture has led to the emergence of resistant microbial species. It should be avoided/minimized by controlling the amount of drug employed in fish farming. For this purpose, the present work proposes test-strip papers aiming at the detection/semi-quantitative determination of organic drugs by visual comparison of color changes, in a similar analytical procedure to that of pH monitoring by universal pH paper. This is done by establishing suitable chemical changes upon cellulose, attributing the paper the ability to react with the organic drug and to produce a color change. Quantitative data is also enabled by taking a picture and applying a suitable mathematical treatment to the color coordinates given by the HSL system used by windows. As proof of concept, this approach was applied to oxytetracycline (OXY), one of the antibiotics frequently used in aquaculture. A bottom-up modification of paper was established, starting by the reaction of the glucose moieties on the paper with 3-triethoxysilylpropylamine (APTES). The so-formed amine layer allowed binding to a metal ion by coordination chemistry, while the metal ion reacted after with the drug to produce a colored compound. The most suitable metals to carry out such modification were selected by bulk studies, and the several stages of the paper modification were optimized to produce an intense color change against the concentration of the drug. The paper strips were applied to the analysis of spiked environmental water, allowing a quantitative determination for OXY concentrations as low as 30ng/mL. In general, this work provided a simple, method to screen and discriminate tetracycline drugs, in aquaculture, being a promising tool for local, quick and cheap monitoring of drugs. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. One primary collimator with optional crystal feature, tested with beam

    CERN Document Server

    EuCARD, Collaboration

    2014-01-01

    The WP8 of EuCARD aims at the design of more advanced materials and collimator concepts for high beam power in particle accelerators like LHC and FAIR. Deliverable 8.3.1 concerned the production and the validation by beam tests of an advanced collimator prototype to improve various aspects of the LHC collimation system, such as the accuracy of the collimator jaw alignment to the circulating beam, the duration of collimator setup time and the overall halo cleaning performance. A collimator prototype was built and installed in the SPS for beam tests in the running period between 2010 and 2012. Crystal collimation aspects were dealt with in a dedicated SPS experiment, which also profited from EuCARD contributions.

  2. Test of a PCIe based readout option for PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Reiter, Simon; Lange, Soeren; Kuehn, Wolfgang [Justus-Liebig-Universitaet Giessen (Germany); Engel, Heiko [Goethe-Universitaet Frankfurt (Germany); Collaboration: PANDA-Collaboration

    2016-07-01

    The future PANDA detector will achieve an event rate at about 20 MHz resulting in a high data load of up to 200 GB/s. The data acquisition system will be based on a triggerless readout concept, leading to the requirement of large data bandwidths. The data reduction will be guaranteed on the first level by an array of FPGAs running a full on-line reconstruction followed by the second level of a CPU/GPU cluster to achieve a reduction factor more than 1000. The C-RORC (Common Readout Receiver Card), originally developed for ALICE, provides on the one hand 12 optical links with 6.25 Gbps each, and on the other hand a PCIe interface with up to 40 Gbps. The receiver card has been installed and tested, and the firmware has been adjusted for the Panda data format. Test results are presented.

  3. Pico Reentry Probes: Affordable Options for Reentry Measurements and Testing

    Science.gov (United States)

    Ailor, William H.; Kapoor, Vinod B.; Allen, Gay A., Jr.; Venkatapathy, Ethiraj; Arnold, James O.; Rasky, Daniel J.

    2005-01-01

    It is generally very costly to perform in-space and atmospheric entry experiments. This paper presents a new platform - the Pico Reentry Probe (PREP) - that we believe will make targeted flight-tests and planetary atmospheric probe science missions considerably more affordable. Small, lightweight, self-contained, it is designed as a "launch and forget" system, suitable for experiments that require no ongoing communication with the ground. It contains a data recorder, battery, transmitter, and user-customized instrumentation. Data recorded during reentry or space operations is returned at end-of-mission via transmission to Iridium satellites (in the case of earth-based operations) or a similar orbiting communication system for planetary missions. This paper discusses possible applications of this concept for Earth and Martian atmospheric entry science. Two well-known heritage aerodynamic shapes are considered as candidates for PREP: the shape developed for the Planetary Atmospheric Experiment Test (PAET) and that for the Deep Space II Mars Probe.

  4. Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Xiaoxiao; Zhang, Weiying; Lin, Yuehe; Du, Dan

    2013-12-15

    An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.

  5. Comprehensive Test Ban Treaty: options before nuclear Pakistan

    International Nuclear Information System (INIS)

    Pattanaik, Smruti S.

    1998-01-01

    The post-nuclear period has rendered Pakistan's strategic calculations more vulnerable. The decision to go nuclear after seventeen days of debate have started proving costly to Pakistan. This is revealed by the economic crisis resulting out of the foreign currency shortage, leading the country to default on the payment of debts. The pressure imposed by the International Monetary Fund (IMF) and World Bank and their patrons to sign the Comprehensive Test Ban Treaty (CTBT) have exposed Pakistan's economic vulnerability. Under this growing pressure, many have started questioning the decision to go nuclear

  6. An ultra-sensitive monoclonal antibody-based fluorescent microsphere immunochromatographic test strip assay for detecting aflatoxin M1 in milk

    Science.gov (United States)

    A rapid lateral flow fluorescent microspheres immunochromatography test strip (FMs-ICTS) has been developed for the detection of aflatoxin M1 (AFM1) residues in milk. For this purpose, an ultra-sensitive anti-AFM1 monoclonal antibody (MAb) 1D3 was prepared and identified. The IC50 value of the MA...

  7. Investigation of the charge collection for strongly irradiated silicon strip detectors of the CMS ECAL Preshower

    International Nuclear Information System (INIS)

    Bloch, Ph.; Peisert, A.; Chang, Y.H.; Chen, A.E.; Hou, S.; Lin, W.T.; Cheremukhin, A.E.; Golutvin, I.A.; Urkinbaev, A.R.; Zamyatin, N.I.; Loukas, D.

    2001-01-01

    Strongly irradiated (2.3·10 14 n/cm 2 ) silicon strip detectors of different size, thickness and different design options were tested in a muon beam at CERN in 1999. A charge collection efficiency in excess of 85% and a signal-to-noise ratio of about 6 are obtained in all cases at high enough bias voltage. Details of the charge collection in the interstrip and the guard ring region and cross-talk between strips were also studied. We find that the charge collection efficiency and the cross-talk between strips depend on the interstrip distance

  8. Stripping Voltammetry

    Science.gov (United States)

    Lovrić, Milivoj

    Electrochemical stripping means the oxidative or reductive removal of atoms, ions, or compounds from an electrode surface (or from the electrode body, as in the case of liquid mercury electrodes with dissolved metals) [1-5]. In general, these atoms, ions, or compounds have been preliminarily immobilized on the surface of an inert electrode (or within it) as the result of a preconcentration step, while the products of the electrochemical stripping will dissolve in the electrolytic solution. Often the product of the electrochemical stripping is identical to the analyte before the preconcentration. However, there are exemptions to these rules. Electroanalytical stripping methods comprise two steps: first, the accumulation of a dissolved analyte onto, or in, the working electrode, and, second, the subsequent stripping of the accumulated substance by a voltammetric [3, 5], potentiometric [6, 7], or coulometric [8] technique. In stripping voltammetry, the condition is that there are two independent linear relationships: the first one between the activity of accumulated substance and the concentration of analyte in the sample, and the second between the maximum stripping current and the accumulated substance activity. Hence, a cumulative linear relationship between the maximum response and the analyte concentration exists. However, the electrode capacity for the analyte accumulation is limited and the condition of linearity is satisfied only well below the electrode saturation. For this reason, stripping voltammetry is used mainly in trace analysis. The limit of detection depends on the factor of proportionality between the activity of the accumulated substance and the bulk concentration of the analyte. This factor is a constant in the case of a chemical accumulation, but for electrochemical accumulation it depends on the electrode potential. The factor of proportionality between the maximum stripping current and the analyte concentration is rarely known exactly. In fact

  9. Asset stripping and firm survival in mass privatization: testing the Hoff-Stiglitz and Campos-Giovannoni models in Montenegro

    Czech Academy of Sciences Publication Activity Database

    Koman, M.; Lakićević, M.; Prašnikar, J.; Švejnar, Jan

    2015-01-01

    Roč. 43, č. 2 (2015), s. 274-289 ISSN 0147-5967 Institutional support: PRVOUK-P23 Keywords : asset stripping * mass privatization * firm survival Subject RIV: AH - Economics Impact factor: 1.380, year: 2015

  10. Results Of The Extraction-Scrub-Strip Testing Using An Improved Solvent Formulation And Salt Waste Processing Facility Simulated Waste

    International Nuclear Information System (INIS)

    Peters, T.; Washington, A.; Fink, S.

    2012-01-01

    The Office of Waste Processing, within the Office of Technology Innovation and Development, is funding the development of an enhanced solvent - also known as the next generation solvent (NGS) - for deployment at the Savannah River Site to remove cesium from High Level Waste. The technical effort is a collaborative effort between Oak Ridge National Laboratory (ORNL) and Savannah River National Laboratory (SRNL). As part of the program, the Savannah River National Laboratory (SRNL) has performed a number of Extraction-Scrub-Strip (ESS) tests. These batch contact tests serve as first indicators of the cesium mass transfer solvent performance with actual or simulated waste. The test detailed in this report used simulated Tank 49H material, with the addition of extra potassium. The potassium was added at 1677 mg/L, the maximum projected (i.e., a worst case feed scenario) value for the Salt Waste Processing Facility (SWPF). The results of the test gave favorable results given that the potassium concentration was elevated (1677 mg/L compared to the current 513 mg/L). The cesium distribution value, DCs, for extraction was 57.1. As a comparison, a typical D Cs in an ESS test, using the baseline solvent formulation and the typical waste feed, is ∼15. The Modular Caustic Side Solvent Extraction Unit (MCU) uses the Caustic-Side Solvent Extraction (CSSX) process to remove cesium (Cs) from alkaline waste. This process involves the use of an organic extractant, BoBCalixC6, in an organic matrix to selectively remove cesium from the caustic waste. The organic solvent mixture flows counter-current to the caustic aqueous waste stream within centrifugal contactors. After extracting the cesium, the loaded solvent is stripped of cesium by contact with dilute nitric acid and the cesium concentrate is transferred to the Defense Waste Processing Facility (DWPF), while the organic solvent is cleaned and recycled for further use. The Salt Waste Processing Facility (SWPF), under

  11. A Dual Electrochemical Sensor Based on a Test-strip Assay for the Quantitative Determination of Albumin and Creatinine.

    Science.gov (United States)

    Yasukawa, Tomoyuki; Kiba, Yuya; Mizutani, Fumio

    2015-01-01

    A dual-electrochemical sensor based on a test-strip assay with immunochemistry and enzyme reactions has been developed for the determination of albumin and creatinine. Each nitrocellulose membrane with an immobilization area of an anti-albumin antibody or three enzymes was prepared in the device with three working electrodes for measuring albumin, creatinine, and ascorbic acid, as well as an Ag/AgCl electrode used as a counter/pseudo-reference electrode. The reactions of three enzymes were initiated by flowing a solution containing creatinine to detect an oxidation current of hydrogen peroxide. A sandwich-type immunocomplex was formed by albumin and antibody labeled with glucose oxidase (GOx). Captured GOx catalyzed the reduction of Fe(CN)6(3-) to Fe(CN)6(4-), which was oxidized electrochemically to determine the captured albumin. The responses for creatinine and albumin increased with the concentrations in millimolar order and over the range 18.75 - 150 μg mL(-1), respectively. The present sensor would be a distinct demonstration for producing quantitative dual-assays for various biomolecules used for clinical diagnoses.

  12. The no-arbitrage efficiency test of the OMX Index option market

    DEFF Research Database (Denmark)

    Hou, Ai Jun; Wiktorsson, Magnus; Zhao, RuiZhi

    2012-01-01

    In this paper, we test the market efficiency of the OMXS30 Index option market. The market efficiency definition is the absence of arbitrage oppor- tunity in the market. We first check the arbitrage opportunity by examining the boundary conditions and the Put-Call-Parity that must be satisfied...... in the market. Then a variance based efficiency test is performed by establish- ing a risk neutral portfolio and re-balance the initial portfolio in different trading strategies. In order to choose the most appropriate model for option price and hedging strategies, we calibrate several most applied models, i.......e. the BS, Merton, Heston, Bates model and Affine Jump Diffusion models. Our results indicate that the AJD model significantly outperforms other models in the option price forecast and the trading strategies. The bound- ary and the PCP test and the dynamic hedging strategy results evidence...

  13. Diagnostic Value of Leukocyte Esterase Test Strip Reagents for Rapid Clinical Diagnosis of Spontaneous Bacterial Peritonitis in Patients Admitted to Hospital Emergency Departments in Iran.

    Science.gov (United States)

    Hashemian, Amir Masoud; Ahmadi, Koorosh; Zamani Moghaddam, Hamid; Zakeri, Hosein; Davoodi Navakh, Seyed Akbar; Sharifi, Mohammad Davood; Bahrami, Abdollah

    2015-10-01

    Spontaneous bacterial peritonitis (SBP) is a common and important clinical problem and is life-threatening in decompensated liver disease. Ascites fluid test by leukocyte esterase test strip has been recently proposed as an effective and rapid method to diagnose SBP in patients with cirrhosis. This study aimed to evaluate sensitivity and specificity of leukocyte esterase test strip in the diagnosis of SBP. The population of this research was all patients with cirrhosis and ascites admitted to the emergency room at Imam Reza (AS) hospital, Mashhad. A written consent was taken for inclusion in the study. 50 mL ascites sample was taken from all patients for use in a urine test strip (LER) (Urine Test Strips Convergys®Urine Matrix 11). The patient's ascites samples were evaluated for cell counting. Positive dipstick test for LER in this study considered as grade 3 +. The values of WBC > 500 cell/mm(3) or PMN > 250 cell/mm(3) considered as positive result of the gold standard method for the diagnosis of SBP. In this study, 100 patients with ascites due to cirrhosis, with an average age of 38.9 ± 6.54 years were evaluated. Twenty cases had positive results, of whom 17 cases were also detected based on the standard diagnostic criteria and other three cases were healthy individuals. Thus, sensitivity, specificity, positive and negative predictive values, and accuracy of the method were 95%, 96.3%, 85%, 97.5% and 95%, respectively. The use of leukocyte esterase urine dipstick test can be a quick and easy method in early diagnosis of SBP to start the treatment until preparation of SBP-cell count results.

  14. Evaluation of immunochromatographic test (ICT) strips for the serological detection of Babesia bovis and Babesia bigemina infection in cattle from Western Java, Indonesia.

    Science.gov (United States)

    Guswanto, Azirwan; Allamanda, Puttik; Mariamah, Euis Siti; Munkjargal, Tserendorf; Tuvshintulga, Bumduuren; Takemae, Hitoshi; Sivakumar, Thillaiampalam; AbouLaila, Mahmoud; Terkawi, Mohamad Alaa; Ichikawa-Seki, Madoka; Nishikawa, Yoshifumi; Yokoyama, Naoaki; Igarashi, Ikuo

    2017-05-30

    Three types of immunochromatographic test (ICT) strips were prepared for the detection of an antibody response against spherical body protein 4 (SBP-4) of Babesia bovis (bovICT), C-terminal-truncated rhoptry-associated protein 1 (rRAP1/CT17) of B. bigemina (bigICT), and the combination of both proteins (dual-ICT). The evaluation of their performance was conducted using a confirmed positive and negative serum panel for B. bovis and B. bigemina. Together with ELISA, the ICT strips were applied to determine the seroprevalence of bovine babesiosis in Western Java, Indonesia. Among 991 serum samples, 28.4%, 25.3%, and 24.5% of cattle were detected to be seropositive to B. bovis infection using ELISA, bovICT, and dual-ICT, respectively. B. bigemina seropositive was detected in 27.1%, 24.2%, and 22.8% of samples using ELISA, bigICT, and dual-ICT, respectively. The comparison of ICT strips and ELISA results using field serum samples showed good agreement with Kappa values >0.7 between all methods The application of ICT strips is preferable in the field situations where rapid diagnosis is required. Furthermore, the data showed the current seroprevalence of bovine babesiosis in Western Java, Indonesia, and efficient control strategies are needed to reduce economic losses due to the disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. The ATLAS inner detector semiconductor tracker (Si and GaAs strips): review of the 1995 beam tests at the CERN SPS H8 beamline

    International Nuclear Information System (INIS)

    Moorhead, G.F.

    1995-01-01

    This talk will consist of a brief review of the ATLAS Inner Detector (ID) Semiconductor Tracker (SCT) strip detector (both silicon and gallium arsenide) beam tests conducted at the ATLAS test beam facility at the CERN SPS H8 beamline. It will include a brief overview of the H8 facilities, the experimental layout of the SCT/Strip apparatus, the data acquisition system, some of the online software tools and the high precision silicon hodoscope and timing modules used. A very brief indication of some of the main varieties of detector systems tested and the measurements performed will be given. Throughout some emphasis will be placed on the contributions and-interests of members of the Melbourne group. (author)

  16. The Alpha-Defensin Immunoassay and Leukocyte Esterase Colorimetric Strip Test for the Diagnosis of Periprosthetic Infection

    Science.gov (United States)

    Wyatt, M.C.; Beswick, A.D.; Kunutsor, S.K.; Wilson, M.J.; Whitehouse, M.R.; Blom, A.W.

    2016-01-01

    Background: Synovial biomarkers have recently been adopted as diagnostic tools for periprosthetic joint infection (PJI), but their utility is uncertain. The purpose of this systematic review and meta-analysis was to synthesize the evidence on the accuracy of the alpha-defensin immunoassay and leukocyte esterase colorimetric strip test for the diagnosis of PJI compared with the Musculoskeletal Infection Society diagnostic criteria. Methods: We performed a systematic review to identify diagnostic technique studies evaluating the accuracy of alpha-defensin or leukocyte esterase in the diagnosis of PJI. MEDLINE and Embase on Ovid, ACM, ADS, arXiv, CERN DS (Conseil Européen pour la Recherche Nucléaire Document Server), CrossRef DOI (Digital Object Identifier), DBLP (Digital Bibliography & Library Project), Espacenet, Google Scholar, Gutenberg, HighWire, IEEE Xplore (Institute of Electrical and Electronics Engineers digital library), INSPIRE, JSTOR (Journal Storage), OAlster (Open Archives Initiative Protocol for Metadata Harvesting), Open Content, Pubget, PubMed, and Web of Science were searched for appropriate studies indexed from inception until May 30, 2015, along with unpublished or gray literature. The classification of studies and data extraction were performed independently by 2 reviewers. Data extraction permitted meta-analysis of sensitivity and specificity with construction of receiver operating characteristic curves for each test. Results: We included 11 eligible studies. The pooled diagnostic sensitivity and specificity of alpha-defensin (6 studies) for PJI were 1.00 (95% confidence interval [CI], 0.82 to 1.00) and 0.96 (95% CI, 0.89 to 0.99), respectively. The area under the curve (AUC) for alpha-defensin and PJI was 0.99 (95% CI, 0.98 to 1.00). The pooled diagnostic sensitivity and specificity of leukocyte esterase (5 studies) for PJI were 0.81 (95% CI, 0.49 to 0.95) and 0.97 (95% CI, 0.82 to 0.99), respectively. The AUC for leukocyte esterase and PJI

  17. Development and evaluation of test stations for the quality assurance of the silicon micro-strip detector modules for the CMS experiment

    International Nuclear Information System (INIS)

    Poettgens, M.

    2007-01-01

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m 2 , the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control of the quality is done by the members of the 21 participating institutes. Since the access to the silicon micro-strip tracker will be very limited after the installation in the CMS detector the installed modules must be of high quality. For this reason the modules are thoroughly tested and the test results are uploaded to a central database. By the development of a read-out system and the corresponding software the III. Physikalisches Institut made an important contribution for the electrical and functional quality control of hybrids and modules. The read-out system provides all features for the operation and test of hybrids and modules and stands out due to high reliability and simple handling. Because a very user-friedly and highly automated software it became the official test tool and was integrated in various test stands. The test stands, in which the read-out system is integrated in, are described and the tests which are implemented in the corresponding

  18. The effects of size and synthesis methods of gold nanoparticle-conjugated MαHIgG4 for use in an immunochromatographic strip test to detect brugian filariasis

    Science.gov (United States)

    Rabizah Makhsin, Siti; Razak, Khairunisak Abdul; Noordin, Rahmah; Dyana Zakaria, Nor; Chun, Tan Soo

    2012-12-01

    This study describes the properties of colloidal gold nanoparticles (AuNPs) with sizes of 20, 30 and 40 nm, which were synthesized using citrate reduction or seeding-growth methods. Likewise, the conjugation of these AuNPs to mouse anti-human IgG4 (MαHIgG4) was evaluated for an immunochromatographic (ICG) strip test to detect brugian filariasis. The morphology of the AuNPs was studied based on the degree of ellipticity (G) of the transmission electron microscopy images. The AuNPs produced using the seeding-growth method showed lower ellipticity (G ≤ 1.11) as compared with the AuNPs synthesized using the citrate reduction method (G ≤ 1.18). Zetasizer analysis showed that the AuNPs that were synthesized using the seeding-growth method were almost monodispersed with a lower polydispersity index (PDI; PDI≤0.079), as compared with the AuNPs synthesized using the citrate reduction method (PDI≤0.177). UV-visible spectroscopic analysis showed a red-shift of the absorbance spectra after the reaction with MαHIgG4, which indicated that the AuNPs were successfully conjugated. The optimum concentration of the BmR1 recombinant antigen that was immobilized on the surface of the ICG strip on the test line was 1.0 mg ml-1. When used with the ICG test strip assay and brugian filariasis serum samples, the conjugated AuNPs-MαHIgG4 synthesized using the seeding-growth method had faster detection times, as compared with the AuNPs synthesized using the citrate reduction method. The 30 nm AuNPs-MαHIgG4, with an optical density of 4 from the seeding-growth method, demonstrated the best performance for labelling ICG strips because it displayed the best sensitivity and the highest specificity when tested with serum samples from brugian filariasis patients and controls.

  19. The "None of the Above" Option in Multiple-Choice Testing: An Experimental Study

    Science.gov (United States)

    DiBattista, David; Sinnige-Egger, Jo-Anne; Fortuna, Glenda

    2014-01-01

    The authors assessed the effects of using "none of the above" as an option in a 40-item, general-knowledge multiple-choice test administered to undergraduate students. Examinees who selected "none of the above" were given an incentive to write the correct answer to the question posed. Using "none of the above" as the…

  20. Asset stripping and firm survival in mass privatization: testing the Hoff-Stiglitz and Campos-Giovannoni models in Montenegro

    Czech Academy of Sciences Publication Activity Database

    Koman, M.; Lakićević, M.; Prašnikar, J.; Švejnar, Jan

    2015-01-01

    Roč. 43, č. 2 (2015), s. 274-289 ISSN 0147-5967 R&D Projects: GA ČR(CZ) GA15-24642S Institutional support: RVO:67985998 Keywords : asset stripping * mass privatization * firm survival Subject RIV: AH - Economics Impact factor: 1.380, year: 2015

  1. Single Event Effects Test Facility Options at the Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Riemer, Bernie [ORNL; Gallmeier, Franz X [ORNL; Dominik, Laura J [ORNL

    2015-01-01

    Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of integrated circuits (ICs) and systems for use in radiation environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.

  2. Performance Test Results of a Single-sided Silicon Strip Detector with a Radioactive Source and a Proton Beam

    International Nuclear Information System (INIS)

    Ki, Y. I.; Kah, D. H.; Son, D. H.; Kang, H. D.; Kim, H. J.; Kim, H. O.; Bae, J. B.; Ryu, S.; Park, H.; Kim, K. R.

    2007-01-01

    Due to high intrinsic precision and high speed properties of a silicon material, the silicon detector has been used in various applications such as medical imaging detector, radiation detector, positioning detectors in space science and experimental particle physics. High technology, modern equipment, and deep expertise are required to design and fabricate good quality of silicon sensors. Only few facilities in the world can develop silicon sensors which meet requirements of sensor performances. That is one of main reasons that the silicon sensor is so expensive and it takes time to purchase the silicon sensor once it is ordered. We designed and fabricated AC-coupled single-sided silicon strip sensors and developed front-end electronics and DAQ system to read out sensor signals. The silicon strip sensors were fabricated on a 5-in. n-type silicon wafer which has an orientation, high resistivity (>5 kΩ · cm) and a thickness of 380 μm. We measured the signal-to-noise ratio (SNR) of each channel by using a radioactive source and a 45 MeV proton beam from the MC-50 cyclotron at the Korea Institute of Radiological and Medical Science (KIRAMS) in Seoul. We present the measurement results of the SNRs of the silicon strip sensor with a proton beam and radioactive sources

  3. Study of surface properties of ATLAS12 strip sensors and their radiation resistance

    Science.gov (United States)

    Mikestikova, M.; Allport, P. P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J. P.; Wilson, J. A.; Kierstead, J.; Kuczewski, P.; Lynn, D.; Hommels, L. B. A.; Ullan, M.; Bloch, I.; Gregor, I. M.; Tackmann, K.; Hauser, M.; Jakobs, K.; Kuehn, S.; Mahboubi, K.; Mori, R.; Parzefall, U.; Clark, A.; Ferrere, D.; Sevilla, S. Gonzalez; Ashby, J.; Blue, A.; Bates, R.; Buttar, C.; Doherty, F.; McMullen, T.; McEwan, F.; O'Shea, V.; Kamada, S.; Yamamura, K.; Ikegami, Y.; Nakamura, K.; Takubo, Y.; Unno, Y.; Takashima, R.; Chilingarov, A.; Fox, H.; Affolder, A. A.; Casse, G.; Dervan, P.; Forshaw, D.; Greenall, A.; Wonsak, S.; Wormald, M.; Cindro, V.; Kramberger, G.; Mandić, I.; Mikuž, M.; Gorelov, I.; Hoeferkamp, M.; Palni, P.; Seidel, S.; Taylor, A.; Toms, K.; Wang, R.; Hessey, N. P.; Valencic, N.; Hanagaki, K.; Dolezal, Z.; Kodys, P.; Bohm, J.; Stastny, J.; Bevan, A.; Beck, G.; Milke, C.; Domingo, M.; Fadeyev, V.; Galloway, Z.; Hibbard-Lubow, D.; Liang, Z.; Sadrozinski, H. F.-W.; Seiden, A.; To, K.; French, R.; Hodgson, P.; Marin-Reyes, H.; Parker, K.; Jinnouchi, O.; Hara, K.; Sato, K.; Hagihara, M.; Iwabuchi, S.; Bernabeu, J.; Civera, J. V.; Garcia, C.; Lacasta, C.; Marti i Garcia, S.; Rodriguez, D.; Santoyo, D.; Solaz, C.; Soldevila, U.

    2016-09-01

    A radiation hard n+-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the "ATLAS ITk Strip Sensor collaboration" and produced by Hamamatsu Photonics. Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in "punch-through protection" (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1×1016 neq/cm2, by reactor neutron fluence of 1×1015 neq/cm2 and by gamma rays from 60Co up to dose of 1 MGy. The main goal of the present study is to characterize the leakage current for micro-discharge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07.

  4. Photosensitive Strip RETHGEM

    CERN Document Server

    Peskov, Vladimir; Nappi, E.; Oliveira, R.; Paic, G.; Pietropaolo, F.; Picchi, P.

    2008-01-01

    An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our latest designs, the inner electrode consists of a metallic grid and the outer one is made of resistive strips; the latter are manufactured by a screen printing technology on the top of the metallic strips grid The inner metallic grid is used for 2D position measurements whereas the resistive layer provides an efficient spark protected operation at high gains - close to the breakdown limit. Detectors with active areas of 10cm x10cm and 10cm x20cm were tested under various conditions including the operation in photosensitive gas mixtures containing ethylferrocene or TMAE vapors. The new technique could have many applications requiring robust and reliable large area detectors for UV visualization, as for example, in Cherenkov imaging devices.

  5. Monolithic front-end ICs for interpolating cathode pad and strip detectors for GEM

    International Nuclear Information System (INIS)

    O'Connor, P.

    1993-05-01

    We are developing CMOS circuits for readout of interpolating cathode strip and pad chambers for the GEM experiment at the SSC. Because these detectors require position resolution of about 1% of the strip pitch, the electronic noise level must be less than 2000 electrons. Several test chips have been fabricated to demonstrate the feasibility of achieving the combination of low noise, speed, and wide dynamic range in CMOS. Results to date show satisfactory noise and linearity performance. Future development will concentrate on radiation-hardening the central tracker ASIC design, optimizing the shaper peaking time and noise contribution, providing more user-configurable output options, and packaging and test issues

  6. TEMPERATURE MONITORING OPTIONS AVAILABLE AT THE IDAHO NATIONAL LABORATORY ADVANCED TEST REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    J.E. Daw; J.L. Rempe; D.L. Knudson; T. Unruh; B.M. Chase; K.L Davis

    2012-03-01

    As part of the Advanced Test Reactor National Scientific User Facility (ATR NSUF) program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced sensors for irradiation testing. To meet recent customer requests, an array of temperature monitoring options is now available to ATR users. The method selected is determined by test requirements and budget. Melt wires are the simplest and least expensive option for monitoring temperature. INL has recently verified the melting temperature of a collection of materials with melt temperatures ranging from 100 to 1000 C with a differential scanning calorimeter installed at INL’s High Temperature Test Laboratory (HTTL). INL encapsulates these melt wires in quartz or metal tubes. In the case of quartz tubes, multiple wires can be encapsulated in a single 1.6 mm diameter tube. The second option available to ATR users is a silicon carbide temperature monitor. The benefit of this option is that a single small monitor (typically 1 mm x 1 mm x 10 mm or 1 mm diameter x 10 mm length) can be used to detect peak irradiation temperatures ranging from 200 to 800 C. Equipment has been installed at INL’s HTTL to complete post-irradiation resistivity measurements on SiC monitors, a technique that has been found to yield the most accurate temperatures from these monitors. For instrumented tests, thermocouples may be used. In addition to Type-K and Type-N thermocouples, a High Temperature Irradiation Resistant ThermoCouple (HTIR-TC) was developed at the HTTL that contains commercially-available doped molybdenum paired with a niobium alloy thermoelements. Long duration high temperature tests, in furnaces and in the ATR and other MTRs, demonstrate that the HTIR-TC is accurate up to 1800 C and insensitive to thermal neutron interactions. Thus, degradation observed at temperatures above 1100 C with Type K and N thermocouples and decalibration due to transmutation with tungsten

  7. Material and geometry options and performance characteristics for a test reactor

    International Nuclear Information System (INIS)

    Jahshan, S.N.; Fletcher, C.D.; Terry, W.K.

    1993-01-01

    For the past 3 yr, an Idaho National Engineering Laboratory (INEL) design team has studied design options for a new test reactor to provide continued testing services after several aging test reactors in the United States are decommissioned. This new reactor, the Broad Application Test Reactor (BATR), would also fill other currently unmet needs, such as medical isotope production and space reactor component testing. Consideration of user needs, safety requirements, developmental uncertainties, and other factors led to the selection of an evolutionary design with plate fuel and several independently cooled test loops. The fuel would be cooled by light water, but most neutron moderation would come from heavy water or beryllium. The BATR design was tentatively scaled to the Advanced Test Reactor (ATR), an existing reactor at INEL: The power output of BATR is 250 MW(thermal), and the active core heights is 1 m. For safety in loss-of-flow events, the coolant flows upward through the core. The BATR design has one large test loop (with a test space diameter of 15.0 cm) along the central axis of the core and six smaller test loops (with test space diameters of 8.0 cm) centered at 6-deg azimuthal intervals on a 24.71-cm-diam circle around the central core axis

  8. Study of application of option B at integrated leakage tests on Swedish reactor containments; Utredning om tillaempning av option B vid integrala taethetsprover paa svenska reaktorinneslutningar

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Roger [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Reactor Technology

    2004-12-15

    The task of the reactor containment is to protect the environment from radioactive release from the nuclear power plant. The containment is a passive component and one can therefore not verify its success criteria during normal operation. To verify the integrity of the containment one has to perform integrated leakage tests (type A tests). These tests are performed in accordance with either option A or B in the American regulation Appendix J 10 CFR 50. The choice of option is up to the licensee. Option A does not consider the leakage history of the containment. The test interval is fixed and set to three tests equally distributed over ten years. The test pressure shall be at least half of the design basis accident pressure (DBA-pressure). Option B does take the leakage history into consideration and is therefore performance-based. The test interval can be chosen to a maximum of ten years. The test pressure shall be the DBA-pressure. In Sweden the type A tests are performed in accordance with option A. The purpose of this investigation is to investigate whether option B can be used in Sweden without any significant risk impact. Performance of a type A test with half of the design pressure can result in an undetected leak. If a leak is of such characteristic that it does not show any leakage behaviour until it is exposed to a certain level of pressure where it can open itself, the leak can be missed during a test with too low pressure. On the other hand, option B demands a higher test pressure which contributes to the risk during the performance of the type A test. The advantage of a more correct result from the type A test is considered to be greater than the disadvantage of a high test-pressure. Hence, Type A test shall be performed with the realistic DBA-pressure. The work has included a literature study, telephone interviews, local meetings and analyses of existing PSA results and reports in the subject. An investigation of the On-Line Monitoring (OLM) method is

  9. Development and evaluation of test stations for the quality assurance of the silicon micro-strip detector modules for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Poettgens, M.

    2007-11-22

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m{sup 2}, the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control of the quality is done by the members of the 21 participating institutes. Since the access to the silicon micro-strip tracker will be very limited after the installation in the CMS detector the installed modules must be of high quality. For this reason the modules are thoroughly tested and the test results are uploaded to a central database. By the development of a read-out system and the corresponding software the III. Physikalisches Institut made an important contribution for the electrical and functional quality control of hybrids and modules. The read-out system provides all features for the operation and test of hybrids and modules and stands out due to high reliability and simple handling. Because a very user-friedly and highly automated software it became the official test tool and was integrated in various test stands. The test stands, in which the read-out system is integrated in, are described and the tests which are implemented in the

  10. Experimental evidence that wildflower strips increase pollinator visits to crops.

    Science.gov (United States)

    Feltham, Hannah; Park, Kirsty; Minderman, Jeroen; Goulson, Dave

    2015-08-01

    Wild bees provide a free and potentially diverse ecosystem service to farmers growing pollination-dependent crops. While many crops benefit from insect pollination, soft fruit crops, including strawberries are highly dependent on this ecosystem service to produce viable fruit. However, as a result of intensive farming practices and declining pollinator populations, farmers are increasingly turning to commercially reared bees to ensure that crops are adequately pollinated throughout the season. Wildflower strips are a commonly used measure aimed at the conservation of wild pollinators. It has been suggested that commercial crops may also benefit from the presence of noncrop flowers; however, the efficacy and economic benefits of sowing flower strips for crops remain relatively unstudied. In a study system that utilizes both wild and commercial pollinators, we test whether wildflower strips increase the number of visits to adjacent commercial strawberry crops by pollinating insects. We quantified this by experimentally sowing wildflower strips approximately 20 meters away from the crop and recording the number of pollinator visits to crops with, and without, flower strips. Between June and August 2013, we walked 292 crop transects at six farms in Scotland, recording a total of 2826 pollinators. On average, the frequency of pollinator visits was 25% higher for crops with adjacent flower strips compared to those without, with a combination of wild and commercial bumblebees (Bombus spp.) accounting for 67% of all pollinators observed. This effect was independent of other confounding effects, such as the number of flowers on the crop, date, and temperature. Synthesis and applications. This study provides evidence that soft fruit farmers can increase the number of pollinators that visit their crops by sowing inexpensive flower seed mixes nearby. By investing in this management option, farmers have the potential to increase and sustain pollinator populations over time.

  11. Test beam results of the first CMS double-sided strip module prototypes using the CBC2 read-out chip

    Energy Technology Data Exchange (ETDEWEB)

    Harb, Ali, E-mail: ali.harb@desy.de; Mussgiller, Andreas; Hauk, Johannes

    2017-02-11

    The CMS Binary Chip (CBC) is a prototype version of the front-end read-out ASIC to be used in the silicon strip modules of the CMS outer tracking detector during the high luminosity phase of the LHC. The CBC is produced in 130 nm CMOS technology and bump-bonded to the hybrid of a double layer silicon strip module, the so-called 2S-p{sub T} module. It has 254 input channels and is designed to provide on-board trigger information to the first level trigger system of CMS, with the capability of cluster-width discrimination and high-p{sub T} track identification. In November 2013 the first 2S-p{sub T} module prototypes equipped with the CBC chips were put to test at the DESY-II test beam facility. Data were collected exploiting a beam of positrons with an energy ranging from 2 to 4 GeV. In this paper the test setup and the results are presented.

  12. Disposal configuration options for future uses of greater confinement disposal at the Nevada Test Site

    International Nuclear Information System (INIS)

    Price, L.

    1994-09-01

    The US Department of Energy (DOE) is responsible for disposing of a variety of radioactive and mixed wastes, some of which are considered special-case waste because they do not currently have a clear disposal option. The DOE's Nevada Field Office contracted with Sandia National Laboratories to investigate the possibility of disposing of some of this special-case waste at the Nevada Test Site (NTS). As part of this investigation, a review of a near-surface and subsurface disposal options that was performed to develop alternative disposal configurations for special-case waste disposal at the NTS. The criteria for the review included (1) configurations appropriate for disposal at the NTS; (2) configurations for disposal of waste at least 100 ft below the ground surface; (3) configurations for which equipment and technology currently exist; and (4) configurations that meet the special requirements imposed by the nature of special-case waste. Four options for subsurface disposal of special-case waste are proposed: mined consolidated rock, mined alluvium, deep pits or trenches, and deep boreholes. Six different methods for near-surface disposal are also presented: earth-covered tumuli, above-grade concrete structures, trenches, below-grade concrete structures, shallow boreholes, and hydrofracture. Greater confinement disposal (GCD) in boreholes at least 100 ft deep, similar to that currently practiced at the GCD facility at the Area 5 Radioactive Waste Management Site at the NTS, was retained as the option that met the criteria for the review. Four borehole disposal configurations are proposed with engineered barriers that range from the native alluvium to a combination of gravel and concrete. The configurations identified will be used for system analysis that will be performed to determine the disposal configurations and wastes that may be suitable candidates for disposal of special-case wastes at the NTS

  13. Staging Options for the Air Force’s Electronic Combat Test Capability: a Cost Analysis

    Science.gov (United States)

    1990-09-01

    strategic in nature and completely different than daily operating decisions (20:6). Horngren , in his book Cost Accounting : A Managerial Emphasis...AFIT/GCA/LSY/90S-3 DTTC S E-191 J) C, STAGING OPTIONS FOR THE AIR FORCE’S ELECTRONIC COMBAT TEST CAPABILITY: A COST ANALYSIS THESIS Joseph J. Landino...Alternative Costs ......... 56 v AFIT/GCA/LSY/90S-3 Abstract This study’s purpose was to identify the lowest cost aircraft staging base( s ) for the Air

  14. Synthesis of carboxyl-capped and bright YVO4:Eu,Bi nanoparticles and their applications in immunochromatographic test strip assay

    International Nuclear Information System (INIS)

    Luo, Min; Sun, Tian-Ying; Wang, Jia-Hong; Yang, Peng; Gan, Liang; Liang, Li-Lei; Yu, Xue-Feng; Gong, Xing-Hou

    2013-01-01

    Graphical abstract: - Highlights: • The morphology and properties of YVO 4 :Eu,Bi nanoparticles were investigated. • YVO 4 :Eu,Bi were coupled with IgG for bioprobes due to their good properties. • YVO 4 :Eu,Bi were applied to immunochromatographic test strip assay. - Abstract: Carboxyl-capped YVO 4 :Eu,Bi nanoparticles with average diameter of ∼10 nm were synthesized via a copolymer of phosphono and carboxylic acid mediated hydrothermal method. Under a 350 nm ultraviolet light excitation, the YVO 4 :Eu,Bi NPs exhibit sharp and bright red emission peaked at 615 nm and with highest quantum yield of ∼43%. Furthermore, the nanoparticles show good water/buffer stability and feasible bioconjugation benefiting from the carboxylic groups on their surface. Based on these kind optical and surface properties of the YVO 4 :Eu,Bi nanoparticles, an immunochromatographic test strip assay for quantitative determination of human IgG was achieved. This protocol can be extended to other rare-earth nanoparticles with the purpose of developing bioprobes for desired applications

  15. Study of surface properties of ATLAS12 strip sensors and their radiation resistance

    Energy Technology Data Exchange (ETDEWEB)

    Mikestikova, M., E-mail: mikestik@fzu.cz [Academy of Sciences of the Czech Republic, Institute of Physics, Na Slovance 2, 18221 Prague 8 (Czech Republic); Allport, P.P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J.P.; Wilson, J.A. [School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom); Kierstead, J.; Kuczewski, P.; Lynn, D. [Brookhaven National Laboratory, Physics Department and Instrumentation Division, Upton, NY 11973-5000 (United States); Hommels, L.B.A. [Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Ullan, M. [Centro Nacional de Microelectronica (IMB-CNM, CSIC), Campus UAB-Bellaterra, 08193 Barcelona (Spain); Bloch, I.; Gregor, I.M.; Tackmann, K. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); Hauser, M.; Jakobs, K.; Kuehn, S. [Physikalisches Institut, Universität Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); and others

    2016-09-21

    A radiation hard n{sup +}-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the “ATLAS ITk Strip Sensor collaboration” and produced by Hamamatsu Photonics. Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in “punch-through protection” (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1×10{sup 16} n{sub eq}/cm{sup 2}, by reactor neutron fluence of 1×10{sup 15} n{sub eq}/cm{sup 2} and by gamma rays from {sup 60}Co up to dose of 1 MGy. The main goal of the present study is to characterize the leakage current for micro-discharge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07. - Highlights:

  16. Rapid Detection of Prunus Necrotic Ringspot Virus by Reverse Transcription-cross-priming Amplification Coupled with Nucleic Acid Test Strip Cassette.

    Science.gov (United States)

    Huo, Ya-Yun; Li, Gui-Fen; Qiu, Yan-Hong; Li, Wei-Min; Zhang, Yong-Jiang

    2017-11-23

    Prunus necrotic ringspot virus (PNRSV) is one of the most devastating viruses to Prunus spp. In this study, we developed a diagnostic system RT-CPA-NATSC, wherein reverse transcription-cross-priming amplification (RT-CPA) is coupled with nucleic acid test strip cassette (NATSC), a vertical flow (VF) visualization, for PNRSV detection. The RT-CPA-NATSC assay targets the encoding gene of the PNRSV coat protein with a limit of detection of 72 copies per reaction and no cross-reaction with the known Prunus pathogenic viruses and viroids, demonstrating high sensitivity and specificity. The reaction is performed on 60 °C and can be completed less than 90 min with the prepared template RNA. Field sample test confirmed the reliability of RT-CPA-NATSC, indicating the potential application of this simple and rapid detection method in routine test of PNRSV.

  17. Dynamic Underground Stripping Project

    International Nuclear Information System (INIS)

    Aines, R.; Newmark, R.; McConachie, W.; Udell, K.; Rice, D.; Ramirez, A.; Siegel, W.; Buettner, M.; Daily, W.; Krauter, P.; Folsom, E.; Boegel, A.J.; Bishop, D.; Udell, K.

    1992-01-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation and underground imaging techniques for use in rapid cleanup of localized underground spills. Called ''Dynamic Stripping'' to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first 8 months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques before moving the contaminated site in FY 92

  18. Varicose vein stripping

    Science.gov (United States)

    ... stripping; Venous reflux - vein stripping; Venous ulcer - veins Patient Instructions Surgical wound care - open Varicose veins - what to ask your doctor Images Circulatory system References American Family Physician. Management of varicose veins. www.aafp.org/afp/2008/ ...

  19. A dip-and-read test strip for the determination of mercury(II) ion in aqueous samples based on urease activity inhibition.

    Science.gov (United States)

    Shi, Guo-Qing; Jiang, Guibin

    2002-11-01

    A sensitive dip-and-read test strip for the determination of mercury in aqueous samples based on the inhibition of urease reaction by the ion has been developed. The strip has a circular sensing zone that containing two layers: the top layer is a cellulose acetate membrane where urease is immobilized on it; the bottom layer is a pH indicator wafer that is impregnated with urea. The principle of the measurement is based on the disappearance of a yellow spot on the pH indicator wafer. The elapsing time until the disappearance of the spot which depends on the concentration of mercury(II) ion is measured with a stopwatch. Under the experimental conditions, as low as 0.2 ng/ml mercury can be observed with the detection range from 0.2 to 200 ng/ml in water. Organomercury compounds give essentially the same response as inorganic mercury. Heavy-metal ions such as Ag(I), Cu(II), Cd(II), Ni(II), Zn(II), and Pb(II) as well as other sample matrixes basically do not interfere with the mercury measurement.

  20. Model for prediction of strip temperature in hot strip steel mill

    International Nuclear Information System (INIS)

    Panjkovic, Vladimir

    2007-01-01

    Proper functioning of set-up models in a hot strip steel mill requires reliable prediction of strip temperature. Temperature prediction is particularly important for accurate calculation of rolling force because of strong dependence of yield stress and strip microstructure on temperature. A comprehensive model was developed to replace an obsolete model in the Western Port hot strip mill of BlueScope Steel. The new model predicts the strip temperature evolution from the roughing mill exit to the finishing mill exit. It takes into account the radiative and convective heat losses, forced flow boiling and film boiling of water at strip surface, deformation heat in the roll gap, frictional sliding heat, heat of scale formation and the heat transfer between strip and work rolls through an oxide layer. The significance of phase transformation was also investigated. Model was tested with plant measurements and benchmarked against other models in the literature, and its performance was very good

  1. Model for prediction of strip temperature in hot strip steel mill

    Energy Technology Data Exchange (ETDEWEB)

    Panjkovic, Vladimir [BlueScope Steel, TEOB, 1 Bayview Road, Hastings Vic. 3915 (Australia)]. E-mail: Vladimir.Panjkovic@BlueScopeSteel.com

    2007-10-15

    Proper functioning of set-up models in a hot strip steel mill requires reliable prediction of strip temperature. Temperature prediction is particularly important for accurate calculation of rolling force because of strong dependence of yield stress and strip microstructure on temperature. A comprehensive model was developed to replace an obsolete model in the Western Port hot strip mill of BlueScope Steel. The new model predicts the strip temperature evolution from the roughing mill exit to the finishing mill exit. It takes into account the radiative and convective heat losses, forced flow boiling and film boiling of water at strip surface, deformation heat in the roll gap, frictional sliding heat, heat of scale formation and the heat transfer between strip and work rolls through an oxide layer. The significance of phase transformation was also investigated. Model was tested with plant measurements and benchmarked against other models in the literature, and its performance was very good.

  2. An Empirical Test of Efficiency of Exchange-Traded Currency Options in India

    OpenAIRE

    Aparna Bhat; Kirti Arekar

    2015-01-01

    The objective of this paper is to examine efficiency of the exchange-traded currency options market in India. Put-call-futures parity for the USD-INR currency options is studied by analyzing daily closing prices of options and futures for thirty two months on the National Stock Exchange. The study reveals frequent violations of the put-call-futures parity creating significant arbitrage opportunities. The pattern of mispricing varies when examined for time to maturity, option moneyness, liquid...

  3. Immunochromatographic Strip Test for Rapid Detection of Diphtheria Toxin: Description and Multicenter Evaluation in Areas of Low and High Prevalence of Diphtheria

    Science.gov (United States)

    Engler, K. H.; Efstratiou, A.; Norn, D.; Kozlov, R. S.; Selga, I.; Glushkevich, T. G.; Tam, M.; Melnikov, V. G.; Mazurova, I. K.; Kim, V. E.; Tseneva, G. Y.; Titov, L. P.; George, R. C.

    2002-01-01

    An immunochromatographic strip (ICS) test was developed for the detection of diphtheria toxin by using an equine polyclonal antibody as the capture antibody and colloidal gold-labeled monoclonal antibodies specific for fragment A of the diphtheria toxin molecule as the detection antibody. The ICS test has been fully optimized for the detection of toxin from bacterial cultures; the limit of detection was approximately 0.5 ng of diphtheria toxin per ml within 10 min. In a comparative study with 915 pure clinical isolates of Corynebacterium spp., the results of the ICS test were in complete agreement with those of the conventional Elek test. The ICS test was also evaluated for its ability to detect toxigenicity from clinical specimens (throat swabs) in two field studies conducted within areas of the former USSR where diphtheria is epidemic. Eight hundred fifty throat swabs were examined by conventional culture and by use of directly inoculated broth cultures for the ICS test. The results showed 99% concordance (848 of 850 specimens), and the sensitivity and specificity of the ICS test were 98% (95% confidence interval, 91 to 99%) and 99% (95% confidence interval, 99 to 100%), respectively. PMID:11773096

  4. Assessment of Startup Fuel Options for a Test or Demonstration Fast Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Carmack, Jon [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hayes, Steven [Idaho National Lab. (INL), Idaho Falls, ID (United States); Walters, L. C. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    This document explores startup fuel options for a proposed test/demonstration fast reactor. The fuel options considered are the metallic fuels U-Zr and U-Pu-Zr and the ceramic fuels UO2 and UO2-PuO2 (MOX). Attributes of the candidate fuel choices considered were feedstock availability, fabrication feasibility, rough order of magnitude cost and schedule, and the existing irradiation performance database. The reactor-grade plutonium bearing fuels (U-Pu-Zr and MOX) were eliminated from consideration as the initial startup fuels because the availability and isotopics of domestic plutonium feedstock is uncertain. There are international sources of reactor grade plutonium feedstock but isotopics and availability are also uncertain. Weapons grade plutonium is the only possible source of Pu feedstock in sufficient quantities needed to fuel a startup core. Currently, the available U.S. source of (excess) weapons-grade plutonium is designated for irradiation in commercial light water reactors (LWR) to a level that would preclude diversion. Weapons-grade plutonium also contains a significant concentration of gallium. Gallium presents a potential issue for both the fabrication of MOX fuel as well as possible performance issues for metallic fuel. Also, the construction of a fuel fabrication line for plutonium fuels, with or without a line to remove gallium, is expected to be considerably more expensive than for uranium fuels. In the case of U-Pu-Zr, a relatively small number of fuel pins have been irradiated to high burnup, and in no case has a full assembly been irradiated to high burnup without disassembly and re-constitution. For MOX fuel, the irradiation database from the Fast Flux Test Facility (FFTF) is extensive. If a significant source of either weapons-grade or reactor-grade Pu became available (i.e., from an international source), a startup core based on Pu could be reconsidered.

  5. The effect of offering different numbers of colorectal cancer screening test options in a decision aid: a pilot randomized trial

    Directory of Open Access Journals (Sweden)

    Brenner Alison RT

    2008-01-01

    Full Text Available Abstract Background Decision aids can improve decision making processes, but the amount and type of information that they should attempt to communicate is controversial. We sought to compare, in a pilot randomized trial, two colorectal cancer (CRC screening decision aids that differed in the number of screening options presented. Methods Adults ages 48–75 not currently up to date with screening were recruited from the community and randomized to view one of two versions of our previously tested CRC screening decision aid. The first version included five screening options: fecal occult blood test (FOBT, sigmoidoscopy, a combination of FOBT and sigmoidoscopy, colonoscopy, and barium enema. The second discussed only the two most frequently selected screening options, FOBT and colonoscopy. Main outcomes were differences in screening interest and test preferences between groups after decision aid viewing. Patient test preference was elicited first without any associated out-of-pocket costs (OPC, and then with the following costs: FOBT-$10, sigmoidoscopy-$50, barium enema-$50, and colonoscopy-$200. Results 62 adults participated: 25 viewed the 5-option decision aid, and 37 viewed the 2-option version. Mean age was 54 (range 48–72, 58% were women, 71% were White, 24% African-American; 58% had completed at least a 4-year college degree. Comparing participants that viewed the 5-option version with participants who viewed the 2-option version, there were no differences in screening interest after viewing (1.8 vs. 1.9, t-test p = 0.76. Those viewing the 2-option version were somewhat more likely to choose colonoscopy than those viewing the 5-option version when no out of pocket costs were assumed (68% vs. 46%, p = 0.11, but not when such costs were imposed (41% vs. 42%, p = 1.00. Conclusion The number of screening options available does not appear to have a large effect on interest in colorectal cancer screening. The effect of offering differing

  6. Immunochromatographic Lateral-flow test strip for the rapid detection of added bovine rennet whey in milk and milk powder

    NARCIS (Netherlands)

    Martin-Hernandez, C.; Munoz, M.; Daury, C.; Weymuth, H.; Kemmers-Voncken, A.; Corbation, V.; Toribo, T.; Bremer, M.G.E.G.

    2009-01-01

    An immunochromatographic lateral-flow test dipstick test was developed for the fast detection of bovine rennet whey in liquid milk and milk powder. The test is based on the binding of casein glycomacropeptide (cGMP) by two specific anti-bovine ¿-casein monoclonal antibodies and has a visual

  7. 40 CFR Table 6 to Subpart IIIi of... - Optional 3-Mode Test Cycle for Stationary Fire Pump Engines

    Science.gov (United States)

    2010-07-01

    ... Engines [As stated in § 60.4210(g), manufacturers of fire pump engines may use the following test cycle... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Optional 3-Mode Test Cycle for Stationary Fire Pump Engines 6 Table 6 to Subpart IIII of Part 60 Protection of Environment ENVIRONMENTAL...

  8. LYCORIS - A Large Area Strip Telescope

    CERN Document Server

    Krämer, U; Stanitzki, M; Wu, M

    2018-01-01

    The LYCORIS Large Area Silicon Strip Telescope for the DESY II Test Beam Facility is presented. The DESY II Test Beam Facility provides elec- tron and positron beams for beam tests of up to 6 GeV. A new telescope with a large 10 × 20 cm2 coverage area based on a 25 μm pitch strip sensor is to be installed within the PCMAG 1 T solenoid. The current state of the system is presented.

  9. Final Report - Assessment of Testing Options for the NTR at the INL

    Energy Technology Data Exchange (ETDEWEB)

    Howe, Steven D; McLing, Travis L; McCurry, Michael; Plummer, Mitchell A

    2013-02-01

    non-nuclear , sub-scale test using gas injection to validate the computational models; 4) Produce a preliminary cost estimate to build a nuclear furnace equivalent facility to test NTR fuel on a green field location on the INL site. The results show that the INL geology is substantially better suited to the SAFE testing method than the NTS site. The existence of impermeable interbeds just above the sub-surface aquifer ensure that no material from the test, radioactive or not, can enter the water table. Similar beds located just below the surface will prevent any gaseous products from reaching the surface for dispersion. The extremely high permeability of the strata between the interbeds allows rapid dispersion of the rocket exhaust. In addition, the high permeability suggests that a lower back-pressure may develop in the hole against the rocket thrust, which increases safety of operations. Finally, the cost of performing a sub-scale, non-nuclear verification experiment was determined to be $3M. The third method was assessed through discussions with INL staff resident at the site. In essence, any new Category I facility on any DOE site will cost in excess of $250M. Based on the results of this study, a cost estimate for testing a nuclear rocket at the INL site appears to be warranted. Given the fact that a new nuclear fuel may be possible that does not release any fission products, the SAFE testing option appears to be the most affordable.

  10. Ultrasonic examination of JBK-75 strip material

    International Nuclear Information System (INIS)

    Cook, K.V.; Cunningham, R.A. Jr.; Lewis, J.C.; McClung, R.W.

    1982-12-01

    An ultrasonic inspection system was assembled to inspect the JBK-75 stainless steel sheath material (for the Large Coil Project) for the Westinghouse-Airco superconducting magnet program. The mechanical system provided for handling the 180-kg (400-lb) coils of strip material [1.6 mm thick by 78 mm wide by 90 to 120 m long (0.064 by 3.07 in. by 300 to 400 ft)], feeding the strip through the ultrasonic inspection and cleaning stations, and respooling the coils. We inspected 54 coils of strip for both longitudinal and laminar flaws. Simulated flaws were used to calibrate both inspections. Saw-cut notches [0.28 mm deep (0.011 in., about 17% of the strip thickness)] were used to calibrate the longitudinal flaw inspections; 1.59-mm-diam (0.063-in.) flat-bottom holes drilled halfway through a calibration strip were used to calibrate the laminar flaw tests

  11. Examining Innovative Divertor and Main Chamber Options for a National Divertor Test Tokamak

    Science.gov (United States)

    Labombard, B.; Umansky, M.; Brunner, D.; Kuang, A. Q.; Marmar, E.; Wallace, G.; Whyte, D.; Wukitch, S.

    2016-10-01

    The US fusion community has identified a compelling need for a National Divertor Test Tokamak. The 2015 Community Planning Workshop on PMI called for a national working group to develop options. Important elements of a NDTT, adopted from the ADX concept, include the ability to explore long-leg divertor `solutions for power exhaust and particle control' (Priority Research Direction B) and to employ inside-launch RF actuators combined with double-null topologies as `plasma solution for main chamber wall components, including tools for controllable sustained operation' (PRD-C). Here we examine new information on these ideas. The projected performance of super-X and X-point target long-leg divertors is looking very promising; a stable fully-detached divertor condition handling an order-of-magnitude increase in power handling over conventional divertors may be possible. New experiments on Alcator C-Mod are addressing issues of high-field side versus low-field side heat flux sharing in double-null topologies and the screening of impurities that might originate from RF actuators placed in the high-field side - both with favorable results. Supported by USDoE Awards DE-FC02-99ER54512 and DE-AC52-07NA27344.

  12. Decisions, decisions: analysis of age, cohort, and time of testing on framing of risky decision options.

    Science.gov (United States)

    Mayhorn, Christopher B; Fisk, Arthur D; Whittle, Justin D

    2002-01-01

    Decision making in uncertain environments is a daily challenge faced by adults of all ages. Framing decision options as either gains or losses is a common method of altering decision-making behavior. In the experiment reported here, benchmark decision-making data collected in the 1970s by Tversky and Kahneman (1981, 1988) were compared with data collected from current samples of young and older adults to determine whether behavior was consistent across time. Although differences did emerge between the benchmark and the present samples, the effect of framing on decision behavior was relatively stable. The present findings suggest that adults of all ages are susceptible to framing effects. Results also indicated that apparent age differences might be better explained by an analysis of cohort and time-of-testing effects. Actual or potential applications of this research include an understanding of how framing might influence the decision-making behavior of people of all ages in a number of applied contexts, such as product warning interactions and medical decision scenarios.

  13. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China); Hao, Fen [DaAn Gene Co. Ltd. of Sun Yat-sen University, 19 Xiangshan Road, Guangzhou 510515 (China); Wu, Ying-Song, E-mail: wg@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China)

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (H{sub T}) and the control line (H{sub C}); the H{sub T}/H{sub C} ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0–1000 IU mL{sup −1}) for AFP with a low limit of detection (0.1 IU mL{sup −1}) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. - Highlights: • Europium (III) chelate microparticles was used as a label for LIFA. • Quantitative detection by using H{sub T}/H{sub C} ratio was achieved. • LIFA for simple and rapid AFP detection in human serum. • The sensitivity and linearity was more excellent compared with QD-based ICTS. • This method could be developed for rapid point-of-care screening.

  14. Quantitative comparison of 3 enamel-stripping devices in vitro: how precisely can we strip teeth?

    Science.gov (United States)

    Johner, Alexander Marc; Pandis, Nikolaos; Dudic, Alexander; Kiliaridis, Stavros

    2013-04-01

    In this in-vitro study, we aimed to investigate the predictability of the expected amount of stripping using 3 common stripping devices on premolars. One hundred eighty extracted premolars were mounted and aligned in silicone. Tooth mobility was tested with Periotest (Medizintechnik Gulden, Modautal, Germany) (8.3 ± 2.8 units). The selected methods for interproximal enamel reduction were hand-pulled strips (Horico, Hapf Ringleb & Company, Berlin, Germany), oscillating segmental disks (O-drive-OD 30; KaVo Dental, Biberach, Germany), and motor-driven abrasive strips (Orthofile; SDC Switzerland, Lugano-Grancia, Switzerland). With each device, the operator intended to strip 0.1, 0.2, 0.3, or 0.4 mm on the mesial side of 15 teeth. The teeth were scanned before and after stripping with a 3-dimensional laser scanner. Superposition and measurement of stripped enamel on the most mesial point of the tooth were conducted with Viewbox software (dHal Software, Kifissia, Greece). The Wilcoxon signed rank test and the Kruskal-Wallis test were applied; statistical significance was set at alpha ≤ 0.05. Large variations between the intended and the actual amounts of stripped enamel, and between stripping procedures, were observed. Significant differences were found at 0.1 mm of intended stripping (P ≤ 0.05) for the hand-pulled method and at 0.4 mm of intended stripping (P ≤ 0.001 to P = 0.05) for all methods. For all scenarios of enamel reduction, the actual amount of stripping was less than the predetermined and expected amount of stripping. The Kruskal-Wallis analysis showed no significant differences between the 3 methods. There were variations in the stripped amounts of enamel, and the stripping technique did not appear to be a significant predictor of the actual amount of enamel reduction. In most cases, actual stripping was less than the intended amount of enamel reduction. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights

  15. Modeling and Experimental Tests on the Hydraulically Driven Control Rod option for IRIS Reactor

    International Nuclear Information System (INIS)

    Cammi, Antonio; Ricotti, Marco E.; Vitulo, Alessia

    2004-01-01

    The adoption of Internal Control Rod Drive Mechanisms (ICRDMs) represents a valuable alternative to classical, external CRDMs based on electro-magnetic devices, as adopted in current PWRs. The advantages on the safety features of the reactor are apparent: inherent elimination of the Rod Ejection accidents and of possible concerns about the vessel head penetrations. A further positive feedback on the design is the reduction of the primary system overall dimensions. Within the frame of the ICRDM concepts, the Hydraulically Driven Control Rod solution is investigated as a possible option for the IRIS integral reactor. After a brief comparison of the solutions currently proposed for integral reactors, the configuration of the Hydraulic Control Rod device for IRIS, made up by an external movable piston and an internal fixed cylinder, is described. A description of the whole control system is reported as well. Particular attention is devoted to the Control Rod profile characterization, performed by means of a Computational Fluid Dynamics (CFD) analysis. The investigation of the system behavior has been carried out, including the dynamic equilibrium and its stability properties, the withdrawal and insertion step movement and the sensitivity study on command time periods. A suitable dynamic model has been set up for the mentioned purposes: the models corresponding to the various Control Rod system devices have been written in an Object-Oriented language (Modelica), thus allowing an easy implementation of such a system into the simulator for the whole reactor. Finally, a preliminary low pressure, low temperature, reduced length experimental facility has been built. Tests on HDCR stability and operational transients have been performed. The results are compared with the dynamic system model and CFD simulation model, showing good agreement between simulations and experimental data. During these preliminary tests, the control system performed correctly, allowing stable dynamic

  16. An informal judgment assessment of subsidence mitigation options for low-level radioactive waste management on the Nevada Test Site

    International Nuclear Information System (INIS)

    Crowe, B.M.; Besinger, H.; Dolenc, M.

    1999-01-01

    An assessment of options to mitigate the effects of subsidence at low-level radioactive waste disposal sites on the Nevada Test Site was conducted using an informal method of expert judgment. Mitigation options for existing waste cells and future waste cells were identified by a committee composed of knowledgeable personnel from the DOE and DOE-contractors. Eight ranking factors were developed to assess the mitigation options and these factors were scored through elicitation of consensus views from the committee. Different subsets of the factors were applied respectively, to existing waste cells and future waste cells, and the resulting scores were ranked using weighted and unweighted scores. These scores show that there is a large number of viable mitigation options and considerable flexibility in assessing the subsidence issue with a greater range of options for future waste cells compared to existing waste cells. A highly ranked option for both existing and future waste cells is covering the waste cells with a thick closure cap of native alluvium

  17. Tests on a mock-up of the feedback controlled matching options of the ITER ICRH system

    International Nuclear Information System (INIS)

    Grine, D.; Vervier, M.; Messiaen, A.; Dumortier, P.

    2009-01-01

    Automatic control of the matching of the ITER ICRH antenna array on a reference load is presently developed and tested for optimization on a low-powered scaled (1:5) mock-up. Resilience to fast load variations is obtained either by 4 Conjugate-T (CT) or 4 quadrature hybrid circuits, the latter being the reference option. The main results are (i) for the CT option: successful implementation of the simultaneous feedback control of 11 actuators for the matching of the 4 CT and for the control of the array toroidal phasing; (ii) for the hybrid option: the matching and the array current control via feedback control of the decouplers and double stub tuners. This system is being progressively implemented and the simultaneous control of matching and antenna current has already been successfully tested on half of the array for heating and current drive phasings.

  18. The Strip Module

    DEFF Research Database (Denmark)

    Pedersen, Tommy

    1996-01-01

    When the behaviour of a ship in waves is to be predicted it is convenient to have a tool which includes different approaches to the problem.The aim of this project is to develop such a tool named the strip theory module. The strip theory module will consist of submodules dependent on the I...

  19. Science Comic Strips

    Science.gov (United States)

    Kim, Dae Hyun; Jang, Hae Gwon; Shin, Dong Sun; Kim, Sun-Ja; Yoo, Chang Young; Chung, Min Suk

    2012-01-01

    Science comic strips entitled Dr. Scifun were planned to promote science jobs and studies among professionals (scientists, graduate and undergraduate students) and children. To this end, the authors collected intriguing science stories as the basis of scenarios, and drew four-cut comic strips, first on paper and subsequently as computer files.…

  20. Anatomy Comic Strips

    Science.gov (United States)

    Park, Jin Seo; Kim, Dae Hyun; Chung, Min Suk

    2011-01-01

    Comics are powerful visual messages that convey immediate visceral meaning in ways that conventional texts often cannot. This article's authors created comic strips to teach anatomy more interestingly and effectively. Four-frame comic strips were conceptualized from a set of anatomy-related humorous stories gathered from the authors' collective…

  1. Development and evaluation of an immunochromatographic strip test based on the recombinant UL51 protein for detecting antibody against duck enteritis virus

    Directory of Open Access Journals (Sweden)

    Sun Tao

    2010-10-01

    Full Text Available Abstract Background Duck enteritis virus (DEV infection causes substantial economic losses to the worldwide duck-producing areas. The monitoring of DEV-specific antibodies is a key to evaluate the effect of DEV vaccine and develop rational immunization programs. Thus, in this study, an immunochromatographic strip (ICS test was developed for detecting DEV serum antibodies. Results The ICS test is based on membrane chromatography, and uses both the purified recombinant UL51 protein conjugated with colloidal gold and goat anti-rabbit IgG conjugated with colloidal gold as tracers, the purified recombinant UL51 protein as the capture reagent at the test line, and rabbit IgG as the capture reagent at the control line. The specificity of the ICS was evaluated by sera against DEV, Duck hepatitis virus (DHV, Riemerella anatipestifer (RA, Duck E. coli, Muscovy duck parvovirus (MPV, or Duck Influenza viruses (DIV. Only sera against DEV showed the strong positive results. In order to determine the sensitivity of the ICS, anti-DEV serum diluted serially was tested, and the minimum detection limit of 1:128 was obtained. The ICS components, which are provided in a sealed package, require no refrigeration and are stable for 12 months. To evaluate the effect of the ICS, 110 duck serum samples collected from several non-immune duck flocks were simultaneously tested by the ICS test, enzyme-linked immunosorbent assay (ELISA and neutralization test (NT. The results showed that the sensitivity of the ICS test was almost consistent with ELISA and much higher than NT, has low cost, and is rapid (15 min and easy to perform with no requirement of specialized equipment, reagent or technicians. Conclusions In this work, we successfully developed a simple and rapid ICS test for detecting DEV serum antibodies for the first time. The ICS test was high specific and sensitive for the rapid detection of anti-DEV antibodies, and has great potential to be used for the serological

  2. The Differences among Three-, Four-, and Five-Option-Item Formats in the Context of a High-Stakes English-Language Listening Test

    Science.gov (United States)

    Lee, HyeSun; Winke, Paula

    2013-01-01

    We adapted three practice College Scholastic Ability Tests (CSAT) of English listening, each with five-option items, to create four- and three-option versions by asking 73 Korean speakers or learners of English to eliminate the least plausible options in two rounds. Two hundred and sixty-four Korean high school English-language learners formed…

  3. Effect of oil pulling on Streptococcus mutans count in plaque and saliva using Dentocult SM Strip mutans test: A randomized, controlled, triple-blind study

    Directory of Open Access Journals (Sweden)

    Asokan S

    2008-03-01

    Full Text Available Background: Oil pulling has been used extensively for many years, without scientific evidence or proof, as a traditional Indian folk remedy to prevent teeth decay, oral malodor, bleeding gums, dryness of throat and cracked lips, and for strengthening the teeth, gums, and jaws. Aims: The aim of this study was to evaluate the effect of oil pulling with sesame oil on the count of Streptococcus mutans in plaque and saliva of children, using the Dentocult SM Strip mutans test, and to compare its efficacy with that of chlorhexidine mouthwash. Materials and Methods: Twenty age-matched adolescent boys were selected based on information obtained through a questionnaire. They were divided randomly into two groups: the control or chlorhexidine group (group I and the study or oil pulling group (group II; there were ten subjects in each group. Plaque and saliva samples were collected from all the 20 subjects on the strips from the Dentocult SM kit and, after incubation, the presence of S. mutans was evaluated using the manufacturers′ chart. The study group practiced oil pulling with sesame oil and the control group used chlorhexidine mouthwash for 10 min every day in the morning before brushing. Samples were collected from both groups after 24 h, 48 h, 1 week, and 2 weeks and the efficacy of oil pulling was compared with that of chlorhexidine mouthwash. Results: There was a reduction in the S. mutans count in the plaque and saliva samples of both the study and the control groups. The reduction in the S. mutans count in the plaque of the study group was statistically significant after 1 and 2 weeks (P = 0.01 and P = 0.008, respectively; the control group showed significant reduction at all the four time points (P = 0.01, P = 0.04, P = 0.005, and P = 0.005, respectively, at 24 h, 48 h, 1 week, and 2 weeks. In the saliva samples, significant reduction in S. mutans count was seen in the control group at 48 h, 1 week, and 2 weeks (P = 0.02, P = 0.02, P = 0

  4. SIIOS in Alaska - Testing an `In-Vault' Option for a Europa Lander Seismometer.

    Science.gov (United States)

    Bray, V. J.; Weber, R. C.; DellaGiustina, D. N.; Bailey, H.; Schmerr, N. C.; Pettit, E. C.; Dahl, P.; Albert, D.; Avenson, B.; Byrne, S.; Siegler, M.; Bland, M. T.; Patterson, G. W.; Selznick, S.

    2017-12-01

    The surface environment of Europa within the radiation-heavy jovian system, poses extreme technical challenges for potential landed missions. The need for radiation shielding and protection from the cold requires instruments to be housed within a thermally insulated and radiation protected `vault'. Unfortunately, this is non-ideal for seismometers as instrument-to-surface coupling is an important factor in the quality of returned data. Delivering a seismic package to an icy world would therefore benefit from the development of a cold-tolerant, radiation-hardened sensor that can survive outside of a protective vault. If such an instrument package were not technologically mature enough, or if lander safety considerations prevent deployment on lander legs, an in-vault location is still a viable option. For such a case, a better understanding of the transmission of seismic signals received through the lander legs is necessary for interpretation of the received signals. The performance, mass, and volume of the `Seismometer to investigate ice and ocean structure' (SIIOS) already meet or exceed flight requirements identified in lander studies for the icy moon Europa. We are testing this flight-candidate in several configurations around and within a lander mock-up, assuming a 1x1 meter vault with extended legs. We compare the received signals from a SIIOS device on the ice with those received by an identical sensor directly above it in the `vault'. We also compare the data from these single-point receivers to that received by two short base-line arrays - A 4-point "in-vault" array and another 4-point array arranged at the ice surface at the base of the lander legs. Our field-testing is performed at Gulkana Glacier, Alaska. The summer melt season provides kilometer-scale regions of coexisting ice, water, and silicate material, thereby providing seismic contrasts analogous to the ice-water layers and possible sub-surface lakes expected at Europa. We demonstrate the

  5. Charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Kraner, H.W.; Beuttenmuller, R.; Ludlam, T.; Hanson, A.L.; Jones, K.W.; Radeka, V.; Heijne, E.H.M.

    1982-11-01

    The use of position sensitive silicon detectors as very high resolution tracking devices in high energy physics experiments has been a subject of intense development over the past few years. Typical applications call for the detection of minimum ionizing particles with position measurement accuracy of 10 μm in each detector plane. The most straightforward detector geometry is that in which one of the collecting electrodes is subdivided into closely spaced strips, giving a high degree of segmentation in one coordinate. Each strip may be read out as a separate detection element, or, alternatively, resistive and/or capacitive coupling between adjacent strips may be exploited to interpolate the position via charge division measrurements. With readout techniques that couple several strips, the numer of readout channels can, in principle, be reduced by large factors without sacrificing the intrinsic position accuracy. The testing of individual strip properties and charge division between strips has been carried out with minimum ionizing particles or beams for the most part except in one case which used alphs particless scans. This paper describes the use of a highly collimated MeV proton beam for studies of the position sensing properties of representative one dimensional strip detectors

  6. Is 'Opt-Out HIV Testing' a real option among pregnant women in rural districts in Kenya?

    Directory of Open Access Journals (Sweden)

    Wamalwa David

    2011-03-01

    Full Text Available Abstract Background An 'opt-out' policy of routine HIV counseling and testing (HCT is being implemented across sub-Saharan Africa to expand prevention of mother-to-child transmission (PMTCT. Although the underlying assumption is that pregnant women in rural Africa are able to voluntarily consent to HIV testing, little is known about the reality and whether 'opt-out' HCT leads to higher completion rates of PMTCT. Factors associated with consent to HIV testing under the 'opt-out' approach were investigated through a large cross-sectional study in Kenya. Methods Observations during HIV pre-test information sessions were followed by a cross-sectional survey of 900 pregnant women in three public district hospitals carrying out PMTCT in the Busia district. Women on their first antenatal care (ANC visit during the current pregnancy were interviewed after giving blood for HIV testing but before learning their test results. Descriptive statistics and multivariate regression analysis were performed. Results Of the 900 women participating, 97% tested for HIV. Lack of testing kits was the only reason for women not being tested, i.e. nobody declined HIV testing. Despite the fact that 96% had more than four earlier pregnancies and 37% had been tested for HIV at ANC previously, only 17% of the women surveyed knew that testing was optional. Only 20% of those surveyed felt they could make an informed decision to decline HIV testing. Making an informed decision to decline HIV testing was associated with knowing that testing was optional (OR = 5.44, 95%CI 3.44-8.59, not having a stable relationship with the child's father (OR = 1.76, 95%CI 1.02-3.03, and not having discussed HIV testing with a partner before the ANC visit (OR = 2.64 95%CI 1.79-3.86. Conclusion High coverage of HIV testing appears to be achieved at the cost of pregnant women not understanding that testing is optional. Good quality HIV pre-test information is central to ensure that pregnant women

  7. Rapid and quantitative detection of zoonotic influenza A virus infection utilizing coumarin-derived dendrimer-based fluorescent immunochromatographic strip test (FICT).

    Science.gov (United States)

    Yeo, Seon-Ju; Huong, Dinh Thi; Hong, Nguyen Ngoc; Li, Chun-Ying; Choi, Kyunghan; Yu, Kyoungsik; Choi, Du-Young; Chong, Chom-Kyu; Choi, Hak Soo; Mallik, Shyam Kumar; Kim, Hak Sung; Sung, Haan Woo; Park, Hyun

    2014-01-01

    Great efforts have been made to develop robust signal-generating fluorescence materials which will help in improving the rapid diagnostic test (RDT) in terms of sensitivity and quantification. In this study, we developed coumarin-derived dendrimer-based fluorescent immunochromatographic strip test (FICT) assay with enhanced sensitivity as a quantitative diagnostic tool in typical RDT environments. The accuracy of the proposed FICT was compared with that of dot blot immunoassay techniques and conventional RDTs. Through conjugation of coumarin-derived dendrimers with latex beads, fluorescent emission covering broad output spectral ranges was obtained which provided a distinct advantage of easy discrimination of the fluorescent emission of the latex beads with a simple insertion of a long-pass optical filter away from the excitation wavelength. The newly developed FICT assay was able to detect 100 ng/10 μL of influenza A nucleoprotein (NP) antigen within 5 minutes, which corresponded to 2.5-fold higher sensitivity than that of the dot blot immunoassay or conventional RDTs. Moreover, the FICT assay was confirmed to detect at least four avian influenza A subtypes (H5N3, H7N1, H7N7, and H9N2). On applying the FICT to the clinical swab samples infected with respiratory viruses, our FICT assay was confirmed to differentiate influenza H1N1 infection from other respiratory viral diseases. These data demonstrate that the proposed FICT assay is able to detect zoonotic influenza A viruses with a high sensitivity, and it enables the quantitation of the infection intensity by providing the numerical diagnostic values; thus demonstrating enhanced detectability of influenza A viruses.

  8. The Alpha-Defensin Immunoassay and Leukocyte Esterase Colorimetric Strip Test for the Diagnosis of Periprosthetic Infection: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Wyatt, M C; Beswick, A D; Kunutsor, S K; Wilson, M J; Whitehouse, M R; Blom, A W

    2016-06-15

    Synovial biomarkers have recently been adopted as diagnostic tools for periprosthetic joint infection (PJI), but their utility is uncertain. The purpose of this systematic review and meta-analysis was to synthesize the evidence on the accuracy of the alpha-defensin immunoassay and leukocyte esterase colorimetric strip test for the diagnosis of PJI compared with the Musculoskeletal Infection Society diagnostic criteria. We performed a systematic review to identify diagnostic technique studies evaluating the accuracy of alpha-defensin or leukocyte esterase in the diagnosis of PJI. MEDLINE and Embase on Ovid, ACM, ADS, arXiv, CERN DS (Conseil Européen pour la Recherche Nucléaire Document Server), CrossRef DOI (Digital Object Identifier), DBLP (Digital Bibliography & Library Project), Espacenet, Google Scholar, Gutenberg, HighWire, IEEE Xplore (Institute of Electrical and Electronics Engineers digital library), INSPIRE, JSTOR (Journal Storage), OAlster (Open Archives Initiative Protocol for Metadata Harvesting), Open Content, Pubget, PubMed, and Web of Science were searched for appropriate studies indexed from inception until May 30, 2015, along with unpublished or gray literature. The classification of studies and data extraction were performed independently by 2 reviewers. Data extraction permitted meta-analysis of sensitivity and specificity with construction of receiver operating characteristic curves for each test. We included 11 eligible studies. The pooled diagnostic sensitivity and specificity of alpha-defensin (6 studies) for PJI were 1.00 (95% confidence interval [CI], 0.82 to 1.00) and 0.96 (95% CI, 0.89 to 0.99), respectively. The area under the curve (AUC) for alpha-defensin and PJI was 0.99 (95% CI, 0.98 to 1.00). The pooled diagnostic sensitivity and specificity of leukocyte esterase (5 studies) for PJI were 0.81 (95% CI, 0.49 to 0.95) and 0.97 (95% CI, 0.82 to 0.99), respectively. The AUC for leukocyte esterase and PJI was 0.97 (95% CI, 0.95 to 0

  9. Area specific stripping factors for AGS. A method for extracting stripping factors from survey data

    Energy Technology Data Exchange (ETDEWEB)

    Aage, H.K.; Korsbech, U. [Technical Univ. of Denmark (Denmark)

    2006-04-15

    In order to use Airborne Gamma-ray Spectrometry (AGS) for contamination mapping, for source search etc. one must to be able to eliminate the contribution to the spectra from natural radioactivity. This in general is done by a stripping technique. The parameters for performing a stripping have until recently been measured by recording gamma spectra at special calibration sites (pads). This may be cumbersome and the parameters may not be correct when used at low gamma energies for environmental spectra. During 2000-2001 DTU tested with success a new technique for Carborne Gamma-ray Spectrometry (CGS) where the spectra from the surveyed area (or from a similar area) were used for calculating the stripping parameters. It was possible to calculate usable stripping ratios for a number of low energy windows - and weak source signals not detectable by other means were discovered with the ASS technique. In this report it is shown that the ASS technique also works for AGS data, and it has been used for recent Danish AGS tests with point sources. (Check of calibration of AGS parameters.) By using the ASS technique with the Boden data (Barents Rescue) an exercise source was detected that has not been detected by any of the teams during the exercise. The ASS technique therefore seems to be better for search for radiation anomalies than any other method known presently. The experiences also tell that although the stripping can be performed correctly at any altitude there is a variation of the stripping parameters with altitude that has not yet been quite understood. However, even with the oddly variations the stripping worked as expected. It was also observed that one might calculate a single common set of usable stripping factors for all altitudes from the entire data set i.e. some average a, b and c values. When those stripping factors were used the stripping technique still worked well. (au)

  10. Rational use of blood glucose test strips for self-monitoring in patients with diabetes mellitus: Economic impact in the Portuguese healthcare system.

    Science.gov (United States)

    Risso, Teresa; Furtado, Cláudia

    2017-12-01

    Self-monitoring of blood glucose is important for diabetes management in insulin-treated patients, but its effectiveness in patients treated with oral glucose lowering drugs only is not fully supported by current evidence. This paper aims to characterise the prescription patterns of blood glucose test strips (BGTS) in Portugal and estimate the potential cost-savings from the rational use of BGTS. A retrospective analysis of the Portuguese database of electronic medical prescriptions to assess the patterns of BGTS prescription. The database was searched for prescription, from 01 January 2016 to 31 December 2016, of insulin and other antidiabetics, as well as the associated prescriptions of BGTS. 894,637 patients were prescribed antidiabetic medicines during 2016, 82.7% of which were prescribed oral glucose lowering drugs only. BGTS were prescribed to 456,179 patients, being more frequently prescribed in insulin-treated patients. Still, 42.8% of patients treated with oral glucose lowering drugs only were also prescribed BGTS, with large proportion of those being prescribed antidiabetic drugs with lower risk of causing hypoglycaemia and, even so, >200 BGTS/year. Several scenarios for a more rational use of BGTS were estimated to result in cost-savings of up to €9.5 million per year. BGTS were prescribed to more than a third of patients treated with oral glucose lowering drugs only, despite accumulating evidence of their limited effectiveness in this population, resulting in substantial economic burden to the healthcare system. Given the estimated potential cost-savings, rational use of BGTS should be encouraged in Portugal. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Evaluation of an Immunochromatographic Strip (Xenostrip –Tv Test for Diagnosis of Vaginal Trichomoniasis Compared with Wet Mount and PCR Assay

    Directory of Open Access Journals (Sweden)

    MH Feiz-Haddad

    2008-09-01

    Full Text Available "nBackground: Trichomoniasis, caused by Trichomonas vaginalis, is one of the most common sexually transmitted infections in the world. Diagnosis of T. vaginalis is performed by different methods, including wet mount, culture, serological methods and PCR, which required laboratory equipments and expert laboratory personnel. The aim of this study was evaluation of immunochromatographic strip test (Xenostrip-Tv for diagnosis of vaginal trichomoniasis compared with wet mount and PCR assay."nMethods: In this prospective study vaginal swabs were obtained from 100 women with genital complaints demanding a speculum examination, referred to Imam Khomeini and Amir Kabir hospitals in Ahwaz, Khuzestan Province. Samples were first examined by wet mount and Xenostrip-Tv. PCR assay was performed in the next step using TVK3 and TVK7 primers initially. The positive samples were then confirmed by the second PCR assay using TVA5-1 and TVA6 primers."nResults: PCR with TVA5-1 and TVA6 primers was determined as gold standard. The wet mount as well as Xenostrip-Tv sensitivity and specificity were 73.3% and 100%, respectively in comparison with gold standard. The sensitivity and specificity of PCR with primers TVK3 and TVK7 were also determined as 100% and 96.6%, respectively. The infection rates were 14% for wet mount and Xenostrip-Tv, 21% for PCR with primers TVK3 plus TVK7 and 19% with the gold standard PCR using TVA5-1 and TVA6 primers."nConclusion: Xenostrip- Tv could be used for diagnosis of vaginal trichomoniasis in regions with no laboratory diagnostic facilities.

  12. Pavement Stripping in Saudi Arabia: Prediction and Prevention

    Directory of Open Access Journals (Sweden)

    H.I. Al-Abdul Wahhab

    2004-12-01

    Full Text Available Pavement weathering or stripping is a major distress in highway networks in arid regions. Using the Saudi Arabian road network as a case study area, seventeen road test sections were selected, out of which eight were stripped and nine were non-stripped. Aggregates from quarries used to build these sections were also collected and subjected to detailed physical and chemical tests to evaluate the ability of these tests to distinguish between stripped and non-stripped sections. The modified Lottman test was used to distinguish between compacted mixes. In addition, the Swedish Rolling Bottle test, was also found to be effective in being able to distinguish between different asphalt-aggregates for stripping potential. Eleven anti-stripping liquid additives, lime and cement, in addition to two polymers, were evaluated for their ability to reduce/eliminate stripping potential of stripping-prone aggregates. It was found that EE-2 Polymer, Portland cement, and their combination were effective with all aggregate sources.

  13. Women’s Attitudes towards the Option to Choose between Karyotyping and Rapid Targeted Testing during Pregnancy

    Directory of Open Access Journals (Sweden)

    Angelique J. A. Kooper

    2013-01-01

    Full Text Available Objectives. Pregnant women, referred because of an increased risk of fetal Down syndrome, who underwent an invasive prenatal procedure were offered a choice between karyotyping and rapid targeted testing. This study aims to assess women’s attitudes and experiences towards what option to choose. Methods. A retrospective multicentre survey (2008–2010 was conducted among 1370 women. General questions were asked about decision making issues, followed by personal questions about their experiences in choice making, test preference, influence of others, and possible regrets. Results. In total, 90.1% of the respondents (N=825 indicated that pregnant women are able to choose, although 33.1% stated that the choice can best be made by a professional. 18.4% indicated that making a choice places a burden on women. In 96.4%, respondents preferred to have the option to choose again in case of a next pregnancy, whereas 2.7% preferred the choice to be made by a professional. Regret was indicated by 1.2%. Decision making was influenced by others in 64.9%. A slightly higher preference for karyotyping was indicated by 52.7% of the respondents. Conclusions. Positive attitudes and experiences were expressed towards the option to choose. Respondents took decisions freely, although sometimes influenced by a partner or a professional, to follow their individual perspectives.

  14. Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

    Energy Technology Data Exchange (ETDEWEB)

    John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

    2009-01-07

    The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During

  15. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  16. 3D silicon strip detectors

    International Nuclear Information System (INIS)

    Parzefall, Ulrich; Bates, Richard; Boscardin, Maurizio; Dalla Betta, Gian-Franco; Eckert, Simon; Eklund, Lars; Fleta, Celeste; Jakobs, Karl; Kuehn, Susanne; Lozano, Manuel; Pahn, Gregor; Parkes, Chris; Pellegrini, Giulio; Pennicard, David; Piemonte, Claudio; Ronchin, Sabina; Szumlak, Tomasz; Zoboli, Andrea; Zorzi, Nicola

    2009-01-01

    While the Large Hadron Collider (LHC) at CERN has started operation in autumn 2008, plans for a luminosity upgrade to the Super-LHC (sLHC) have already been developed for several years. This projected luminosity increase by an order of magnitude gives rise to a challenging radiation environment for tracking detectors at the LHC experiments. Significant improvements in radiation hardness are required with respect to the LHC. Using a strawman layout for the new tracker of the ATLAS experiment as an example, silicon strip detectors (SSDs) with short strips of 2-3 cm length are foreseen to cover the region from 28 to 60 cm distance to the beam. These SSD will be exposed to radiation levels up to 10 15 N eq /cm 2 , which makes radiation resistance a major concern for the upgraded ATLAS tracker. Several approaches to increasing the radiation hardness of silicon detectors exist. In this article, it is proposed to combine the radiation hard 3D-design originally conceived for pixel-style applications with the benefits of the established planar technology for strip detectors by using SSDs that have regularly spaced doped columns extending into the silicon bulk under the detector strips. The first 3D SSDs to become available for testing were made in the Single Type Column (STC) design, a technological simplification of the original 3D design. With such 3D SSDs, a small number of prototype sLHC detector modules with LHC-speed front-end electronics as used in the semiconductor tracking systems of present LHC experiments were built. Modules were tested before and after irradiation to fluences of 10 15 N eq /cm 2 . The tests were performed with three systems: a highly focused IR-laser with 5μm spot size to make position-resolved scans of the charge collection efficiency, an Sr 90 β-source set-up to measure the signal levels for a minimum ionizing particle (MIP), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of the results obtained with 3D-STC-modules.

  17. 3D silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany)], E-mail: ulrich.parzefall@physik.uni-freiburg.de; Bates, Richard [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Boscardin, Maurizio [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Dalla Betta, Gian-Franco [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Kuehn, Susanne [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Lozano, Manuel [Instituto de Microelectronica de Barcelona, IMB-CNM, CSIC, Barcelona (Spain); Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Pellegrini, Giulio [Instituto de Microelectronica de Barcelona, IMB-CNM, CSIC, Barcelona (Spain); Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Piemonte, Claudio; Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Szumlak, Tomasz [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Zoboli, Andrea [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2009-06-01

    While the Large Hadron Collider (LHC) at CERN has started operation in autumn 2008, plans for a luminosity upgrade to the Super-LHC (sLHC) have already been developed for several years. This projected luminosity increase by an order of magnitude gives rise to a challenging radiation environment for tracking detectors at the LHC experiments. Significant improvements in radiation hardness are required with respect to the LHC. Using a strawman layout for the new tracker of the ATLAS experiment as an example, silicon strip detectors (SSDs) with short strips of 2-3 cm length are foreseen to cover the region from 28 to 60 cm distance to the beam. These SSD will be exposed to radiation levels up to 10{sup 15}N{sub eq}/cm{sup 2}, which makes radiation resistance a major concern for the upgraded ATLAS tracker. Several approaches to increasing the radiation hardness of silicon detectors exist. In this article, it is proposed to combine the radiation hard 3D-design originally conceived for pixel-style applications with the benefits of the established planar technology for strip detectors by using SSDs that have regularly spaced doped columns extending into the silicon bulk under the detector strips. The first 3D SSDs to become available for testing were made in the Single Type Column (STC) design, a technological simplification of the original 3D design. With such 3D SSDs, a small number of prototype sLHC detector modules with LHC-speed front-end electronics as used in the semiconductor tracking systems of present LHC experiments were built. Modules were tested before and after irradiation to fluences of 10{sup 15}N{sub eq}/cm{sup 2}. The tests were performed with three systems: a highly focused IR-laser with 5{mu}m spot size to make position-resolved scans of the charge collection efficiency, an Sr{sup 90}{beta}-source set-up to measure the signal levels for a minimum ionizing particle (MIP), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of

  18. Dynamic Underground Stripping Demonstration Project

    International Nuclear Information System (INIS)

    Aines, R.; Newmark, R.; McConachie, W.; Rice, D.; Ramirez, A.; Siegel, W.; Buettner, M.; Daily, W.; Krauter, P.; Folsom, E.; Boegel, A.J.; Bishop, D.; udel, K.

    1992-03-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation and underground imaging techniques for use in rapid cleanup of localized underground spills. Called ''Dynamic Stripping'' to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first 8 months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques before moving to the contaminated site in FY 92

  19. Selective chemical stripping

    Science.gov (United States)

    Malavallon, Olivier

    1995-04-01

    At the end of the 80's, some of the large European airlines expressed a wish for paint systems with improved strippability on their aircraft, allowing the possibility to strip down to the primer without altering it, using 'mild' chemical strippers based on methylene chloride. These improvements were initially intended to reduce costs and stripping cycle times while facilitating rapid repainting, and this without the need to change the conventionally used industrial facilities. The level of in-service performance of these paint systems was to be the same as the previous ones. Requirements related to hygiene safety and the environment were added to these initial requirements. To meet customers' expectations, Aerospatiale, within the Airbus Industry GIE, formed a work group. This group was given the task of specifying, following up the elaboration and qualifying the paint systems allowing requirements to be met, in relation with the paint suppliers and the airlines. The analysis made in this report showed the interest of transferring as far upstream as possible (to paint conception level) most of the technical constraints related to stripping. Thus, the concept retained for the paint system, allowing selective chemical stripping, is a 3-coat system with characteristics as near as possible to the previously used paints.

  20. ALICE Silicon Strip Detector

    CERN Multimedia

    Nooren, G

    2013-01-01

    The Silicon Strip Detector (SSD) constitutes the two outermost layers of the Inner Tracking System (ITS) of the ALICE Experiment. The SSD plays a crucial role in the tracking of the particles produced in the collisions connecting the tracks from the external detectors (Time Projection Chamber) to the ITS. The SSD also contributes to the particle identification through the measurement of their energy loss.

  1. EMPIRICAL TESTING OF MODIFIED BLACK-SCHOLES OPTION PRICING MODEL FORMULA ON NSE DERIVATIVE MARKET IN INDIA

    Directory of Open Access Journals (Sweden)

    Ambrish Gupta

    2013-01-01

    Full Text Available The main objectives of this paper are to incorporate modification in Black-Scholes option pricing model formula by adding some new variables on the basis of given assumption related to risk-free interest rate, and also shows the calculation process of new risk-free interest rate on the basis of modified variable. This paper also identifies the various situations in empirical testing of modified and original Black-Scholes formula with respect to the market value on the basis of assumed and calculated risk-free interest rate.

  2. The I Don't Know Option in the Vocabulary Size Test

    Science.gov (United States)

    Zhang, Xian

    2013-01-01

    The current study evaluates guessing behaviors in a vocabulary size test (VST) and examines whether including an "I don't know" in a VST may have an impact on the results of the test. One-hundred-fifty first-year students at a university in China took part in the study. They were randomly assigned to three groups. Each group took a…

  3. Artificial Intelligence for Inferential Control of Crude Oil Stripping Process

    Directory of Open Access Journals (Sweden)

    Mehdi Ebnali

    2018-01-01

    Full Text Available Stripper columns are used for sweetening crude oil, and they must hold product hydrogen sulfide content as near the set points as possible in the faces of upsets. Since product    quality cannot be measured easily and economically online, the control of product quality is often achieved by maintaining a suitable tray temperature near its set point. Tray temperature control method, however, is not a proper option for a multi-component stripping column because the tray temperature does not correspond exactly to the product composition. To overcome this problem, secondary measurements can be used to infer the product quality and adjust the values of the manipulated variables. In this paper, we have used a novel inferential control approach base on adaptive network fuzzy inference system (ANFIS for stripping process. ANFIS with different learning algorithms is used for modeling the process and building a composition estimator to estimate the composition of the bottom product. The developed estimator is tested, and the results show that the predictions made by ANFIS structure are in good agreement with the results of simulation by ASPEN HYSYS process simulation package. In addition, inferential control by the implementation of ANFIS-based online composition estimator in a cascade control scheme is superior to traditional tray temperature control method based on less integral time absolute error and low duty consumption in reboiler.

  4. Strip interpolation in silicon and germanium strip detectors

    International Nuclear Information System (INIS)

    Wulf, E. A.; Phlips, B. F.; Johnson, W. N.; Kurfess, J. D.; Lister, C. J.; Kondev, F.; Physics; Naval Research Lab.

    2004-01-01

    The position resolution of double-sided strip detectors is limited by the strip pitch and a reduction in strip pitch necessitates more electronics. Improved position resolution would improve the imaging capabilities of Compton telescopes and PET detectors. Digitizing the preamplifier waveform yields more information than can be extracted with regular shaping electronics. In addition to the energy, depth of interaction, and which strip was hit, the digitized preamplifier signals can locate the interaction position to less than the strip pitch of the detector by looking at induced signals in neighboring strips. This allows the position of the interaction to be interpolated in three dimensions and improve the imaging capabilities of the system. In a 2 mm thick silicon strip detector with a strip pitch of 0.891 mm, strip interpolation located the interaction of 356 keV gamma rays to 0.3 mm FWHM. In a 2 cm thick germanium detector with a strip pitch of 5 mm, strip interpolation of 356 keV gamma rays yielded a position resolution of 1.5 mm FWHM

  5. Application of toxicity testing in the evaluation of reclamation options for oil sands fine tails

    International Nuclear Information System (INIS)

    Nelson, L.R.; MacKinnon, M.; Gulley, J.R.

    1993-01-01

    The hot water process for the extraction of bitumen from oil sands leads to the production of large volumes of wastewater and the formation of a large inventory of fine clay tailings. This fine tailings material and its associated water are acutely toxic to various aquatic test organisms during bioassays. An overview is presented of toxicity testing at Syncrude and Suncor, the application of toxicity testing to fine tailings management, and the role in reclamation planning. The main acutely toxic component of the tailings is the polar organic acid fraction, specifically naphthanates. These naphthanates are readily degraded biologically by indigenous microbial populations. Toxicity testing is aimed at assessing the degree of both acute and chronic toxicity and the long term potential for the input of toxins into the environment from various proposed reclamation measures. 28 refs., 6 figs., 2 tabs

  6. Testbeam evaluation of silicon strip modules for ATLAS Phase - II Strip Tracker Upgrade

    CERN Document Server

    Blue, Andrew; The ATLAS collaboration; Ai, Xiaocong; Allport, Phillip; Arling, Jan-Hendrik; Atkin, Ryan Justin; Bruni, Lucrezia Stella; Carli, Ina; Casse, Gianluigi; Chen, Liejian; Chisholm, Andrew; Cormier, Kyle James Read; Cunningham, William Reilly; Dervan, Paul; Diez Cornell, Sergio; Dolezal, Zdenek; Dopke, Jens; Dreyer, Etienne; Dreyling-Eschweiler, Jan Linus Roderik; Escobar, Carlos; Fabiani, Veronica; Fadeyev, Vitaliy; Fernandez Tejero, Javier; Fleta Corral, Maria Celeste; Gallop, Bruce; Garcia-Argos, Carlos; Greenall, Ashley; Gregor, Ingrid-Maria; Greig, Graham George; Guescini, Francesco; Hara, Kazuhiko; Hauser, Marc Manuel; Huang, Yanping; Hunter, Robert Francis Holub; Keller, John; Klein, Christoph; Kodys, Peter; Koffas, Thomas; Kotek, Zdenek; Kroll, Jiri; Kuehn, Susanne; Lee, Steven Juhyung; Liu, Yi; Lohwasser, Kristin; Meszarosova, Lucia; Mikestikova, Marcela; Mi\\~nano Moya, Mercedes; Mori, Riccardo; Moser, Brian; Nikolopoulos, Konstantinos; Peschke, Richard; Pezzullo, Giuseppe; Phillips, Peter William; Poley, Anne-luise; Queitsch-Maitland, Michaela; Ravotti, Federico; Rodriguez Rodriguez, Daniel

    2018-01-01

    The planned HL-LHC (High Luminosity LHC) is being designed to maximise the physics potential of the LHC with 10 years of operation at instantaneous luminosities of \\mbox{$7.5\\times10^{34}\\;\\mathrm{cm}^{-2}\\mathrm{s}^{-1}$}. A consequence of this increased luminosity is the expected radiation damage requiring the tracking detectors to withstand hadron equivalences to over $1x10^{15}$ 1 MeV neutron equivalent per $cm^{2}$ in the ATLAS Strips system. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics are glued on top of a silicon sensor to make a module. The radiation hard n-in-p micro-strip sensors used have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics. A series of tests were performed at the DESY-II test beam facility to investigate the detailed performance of a strip module with both 2.5cm and 5cm length strips before irradiation. The DURANTA telescope was used to obtain a pointing...

  7. To Show or Not to Show: The Effects of Item Stems and Answer Options on Performance on a Multiple-Choice Listening Comprehension Test

    Science.gov (United States)

    Yanagawa, Kozo; Green, Anthony

    2008-01-01

    The purpose of this study is to examine whether the choice between three multiple-choice listening comprehension test formats results in any difference in listening comprehension test performance. The three formats entail (a) allowing test takers to preview both the question stem and answer options prior to listening; (b) allowing test takers to…

  8. An updated dose assesment for resettlement options at Bikini atoll - A US nuclear test site

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1997-01-01

    There has been a continuing effort since 1977 to refine dose assessments for resettlement options at Bikini Atoll. Here we provide a radiological dose assessment for the main residence island, Bikini, using extensive radio nuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island as part of our continuing research and monitoring program that began in 1978. The unique composition of coral soil greatly alters the relative contribution of 137 Cs and 90 Sr to the total estimated dose relative to expectations based on North American and European soils. Without counter measures, 137 Cs produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The doses are calculated assuming a resettlement date of 1999. The estimated maximum annual effective dose for current island conditions is 4.0 mSv when imported foods, which are now an established part of the diet, are available. The 30-, 50-, and 70-y integral effective doses are 91 mSv, 130 mSv, and 150 mSv, respectively. A detailed uncertainty analysis for these dose estimates is presented in a companion paper in this issue. We have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to about 5 % of pretreatment levels and has essentially no negative environmental consequences. We have calculated the dose for the rehabilitation scenario where the top 40 cm of soil is removed in the housing and village area, and the rest of the island is treated with potassium fertilizer; the maximum annual effective dose is 0.41 mSv and the 30-, 50-, and 70-y integral effective doses are 9.8 mSv, 14 mSv, and 16 mSv, respectively. 44 refs., 3 figs., 11 tabs

  9. TIBER II/ETR [Engineering Test Reactor] nuclear shielding and optional tritium breeding system: An overview

    International Nuclear Information System (INIS)

    Lee, J.D.; Sawan, M.

    1987-01-01

    TIBER II, the Tokamak Ignition/Burn Experimental Reactor II, is a design concept developed as the US candidate for an International Engineering Test Reactor (ETR). An important objective of this design is to minimize cost by minimizing major radius while providing a wall loading greater than 1.0 MW/m2 and a total fluence greater than 3.0 MWY/m2 needed for blanket module testing. The shielding required for the superconducting TF coils is an important element in setting TIBER II's 3.0m major radius. 6 refs., 1 fig., 1 tab

  10. Micro-strip sensors based on CVD diamond

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D. E-mail: dirk.meier@cern.ch; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M

    2000-10-11

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  11. Micro-strip sensors based on CVD Diamond

    CERN Document Server

    Adam, W; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Koeth, T W; Krammer, Manfred; Lo Giudice, A; Lü, R; MacLynne, L; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Perera, L P; Pirollo, S; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S R; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Wetstein, M; White, C; Zeuner, W; Zoeller, M M

    2000-01-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  12. Micro-strip sensors based on CVD diamond

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.

    2000-01-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation

  13. Micro-strip sensors based on CVD diamond

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; RD42 Collaboration

    2000-10-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  14. Energy options

    International Nuclear Information System (INIS)

    Hampton, Michael

    1999-01-01

    This chapter focuses on energy options as a means of managing exposure to energy prices. An intuitive approach to energy options is presented, and traditional definitions of call and put options are given. The relationship between options and swaps, option value and option exercises, commodity options, and option pricing are described. An end-user's guide to energy option strategy is outlined, and straight options, collars, participating swaps and collars, bull and bear spreads, and swaption are examined. Panels explaining the defining of basis risk, and discussing option pricing and the Greeks, delta hedging, managing oil options using the Black-Scholes model, caps, floors and collars, and guidelines on hedging versus speculation with options are included in the paper

  15. Development and testing of a three-stage double tandem accelerator-decelerator system for low energy, highly stripped ions. Progress report, March 1, 1978--February 28, 1979

    International Nuclear Information System (INIS)

    Bayfield, J.E.

    1978-11-01

    Three-stage operation of the University of Pittsburgh accel-decel double tandem source of highly stripped ion beams is described. The system has produced 0 5+ , 0 6+ , 0 7+ , and 0 8+ ions at specific energies as low as 15 keV per AMU. The design of the new decelerator tubes is discussed. The present performance and limitations of the overall system are outlined. Some new charge exchange cross sections have been measured, for combined higher ion charge states and lower ion energies than heretofore was possible. Future four-stage operation with very heavy ions is considered

  16. Interpreting results of cluster surveys in emergency settings: is the LQAS test the best option?

    Science.gov (United States)

    Bilukha, Oleg O; Blanton, Curtis

    2008-12-09

    Cluster surveys are commonly used in humanitarian emergencies to measure health and nutrition indicators. Deitchler et al. have proposed to use Lot Quality Assurance Sampling (LQAS) hypothesis testing in cluster surveys to classify the prevalence of global acute malnutrition as exceeding or not exceeding the pre-established thresholds. Field practitioners and decision-makers must clearly understand the meaning and implications of using this test in interpreting survey results to make programmatic decisions. We demonstrate that the LQAS test--as proposed by Deitchler et al.--is prone to producing false-positive results and thus is likely to suggest interventions in situations where interventions may not be needed. As an alternative, to provide more useful information for decision-making, we suggest reporting the probability of an indicator's exceeding the threshold as a direct measure of "risk". Such probability can be easily determined in field settings by using a simple spreadsheet calculator. The "risk" of exceeding the threshold can then be considered in the context of other aggravating and protective factors to make informed programmatic decisions.

  17. Microstructural research on hot strips of low carbon steel produced by a compact strip production line under different thermal histories

    International Nuclear Information System (INIS)

    Yu Hao; Chen Qixiang; Kang Yonglin; Sun Yi

    2005-01-01

    Coupons with the same composition and thickness (4.0 mm nominal gauge) obtained from hot strips of low carbon steel underwent a series of investigations to analyze the microstructural characteristics and mechanisms responsible for their differences in mechanical properties. Two different industrial technologies were adopted, although the strips used in this research were produced on the same Compact Strip Production (CSP) line. One of the strips was produced with a routine γ→α CSP thermal history, but the other with a γ→α→γ* conventional thermal history. The only difference between them was that one technology had a α→γ* thermal history. Different specimens of both types of strips were prepared for metallographic observation, tensile tests, electron back-scattered diffraction tests and positron annihilation technique tests. Experimental results showed that the differences in mechanical properties could be ascribed to dissimilarities not only in the grain size and textural components but also in dislocation density

  18. Development of floating strip micromegas detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, Jonathan

    2014-04-28

    track inclination in a single detector plane is studied and optimized. A quantitative description of the systematic deviations of the method is developed, that allows for correcting the reconstructed track inclinations. The low material budget detector is tested in therapeutic proton and carbon ion beams at particle rates between 2 MHz and 2 GHz. No reduction of the detector up-time due to discharges is observed. The measurable pulse height decreases by only 20% for an increase of particle rate from 2 MHz to 80 MHz. Efficient single particle tracking is possible at flux densities up to 7 MHz/cm{sup 2}. The good multi-hit resolution of floating strip Micromegas is shown.

  19. Development of floating strip micromegas detectors

    International Nuclear Information System (INIS)

    Bortfeldt, Jonathan

    2014-01-01

    detector plane is studied and optimized. A quantitative description of the systematic deviations of the method is developed, that allows for correcting the reconstructed track inclinations. The low material budget detector is tested in therapeutic proton and carbon ion beams at particle rates between 2 MHz and 2 GHz. No reduction of the detector up-time due to discharges is observed. The measurable pulse height decreases by only 20% for an increase of particle rate from 2 MHz to 80 MHz. Efficient single particle tracking is possible at flux densities up to 7 MHz/cm 2 . The good multi-hit resolution of floating strip Micromegas is shown.

  20. Effect of fluoride varnish on Streptococcus mutans counts in plaque of caries-free children using Dentocult SM strip mutans test: a randomized controlled triple blind study.

    Science.gov (United States)

    Jeevarathan, J; Deepti, A; Muthu, M S; Rathna Prabhu, V; Chamundeeswari, G S

    2007-01-01

    Dental caries is one of the most prevalent infectious diseases and although of multifactorial origin, Streptococcus mutans is considered the chief pathogen in its development. Fluoride is one of the most effective agents used for the reduction of dental caries apart from oral hygiene maintenance. The aim of this study was to estimate the counts of Streptococcus mutans and to evaluate the effect of Fluor Protector fluoride varnish on these counts in the plaque of caries-free children using Dentocult SM Strip Mutans. Thirty caries-free subjects were selected for the study based on the information obtained from a questionnaire and were randomly assigned to the control group consisting of ten subjects and the study group consisting of twenty subjects. Plaque samples were collected on the strips from the Dentocult SM kit and after incubation, the presence of Streptococcus mutans was evaluated using the manufacturer's chart. The study group was subjected to a Fluor Protector fluoride varnish application following which the samples were collected again after 24 hours. The average Streptococcus mutans counts in the primary dentition of caries-free children before and after the application of Fluor Protector fluoride varnish were 10(4)-10(5) colony forming units (CFU)/ml and <10(4) CFU/ml respectively. The results showed that the study group had a statistically significant reduction in the plaque Streptococcus mutans counts than the control group.

  1. Effect of fluoride varnish on Streptococcus mutans counts in plaque of caries-free children using dentocult SM strip mutans test: A randomized controlled triple blind study

    Directory of Open Access Journals (Sweden)

    Jeevarathan J

    2007-01-01

    Full Text Available Dental caries is one of the most prevalent infectious diseases and although of multifactorial origin, Streptococcus mutans is considered the chief pathogen in its development. Fluoride is one of the most effective agents used for the reduction of dental caries apart from oral hygiene maintenance. Aims: The aim of this study was to estimate the counts of Streptococcus mutans and to evaluate the effect of Fluor Protector fluoride varnish on these counts in the plaque of caries-free children using Dentocult SM Strip Mutans. Materials and Methods: Thirty caries-free subjects were selected for the study based on the information obtained from a questionnaire and were randomly assigned to the control group consisting of ten subjects and the study group consisting of twenty subjects. Plaque samples were collected on the strips from the Dentocult SM kit and after incubation, the presence of Streptococcus mutans was evaluated using the manufacturer′s chart. The study group was subjected to a Fluor Protector fluoride varnish application following which the samples were collected again after 24 hours. Results: The average Streptococcus mutan s counts in the primary dentition of caries-free children before and after the application of Fluor Protector fluoride varnish were 10 4 -10 5 colony forming units (CFU/ml and < 10 4 CFU/ml respectively. Conclusion: The results showed that the study group had a statistically significant reduction in the plaque Streptococcus mutans counts than the control group.

  2. Development and Evaluation of Test Stations for the Quality Assurance of the Silicon Micro-Strip Detector Modules for the CMS Experiment

    CERN Document Server

    Pöttgens, Michael

    2007-01-01

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m2, the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control o...

  3. Utilidad de sangre almacenada en papel de filtro para estudios serologicos por ELISA de inhibicion Use of filter paper strips on an ELISA inhibition test for serologic studies on dengue

    Directory of Open Access Journals (Sweden)

    S. Vázquez

    1991-08-01

    Full Text Available Para evaluar la utilidad del método de recolección de muestras de sangre en papel de filtro para la detección de anticuerpos anti-dengue mediante un ELISA de Inhibición recientemente desarrollado en nuestro laboratorio, se realizó una toma simultánea de muestras de sangre en papel de filtro y de suero, de donantes de Banco de Sangre. Ambas muestras fueron conservadas a -20ºC y probadas a los 15 dias, 3 y 6 meses respectivamente. A las muestras que resultaron positivos se les amplió el rango de dilución para determinar título. Al realizar la comparación entre ambas muestras, sangre en papel de filtro y suero, encontramos que no existían diferencias de detección significativas, tanto para los casos positivos como los negativos. No obstante se observó en ambas muestras y de forma general una disminución del titulo de anticuerpos (una dilución al transcurrir el tiempo máximo establecido en nuestro estudio (6 meses.To evaluate the usefullness of the collecting method of blood samples in filter paper strips for anti-dengue antibody detection using an ELISA Inhibition test which has been recently developed in our laboratory, blood samples collected on filter paper strips and serum samples were obtained from the same blood donors. Both samples were kept at -20ºC and tested at 15 days, 3 and 6 months. Titers were determined in positive samples. Comparing the results, no significant differences were found between serum samples and blood samples collected in filter paper strips in relation to the number of negative and positive cases. Nevertheless, it was observed in both types of samples a decrease of the antibody titers (one dilution in the longest period of our study (6 months.

  4. Arms Control and nonproliferation technologies: Technology options and associated measures for monitoring a Comprehensive Test Ban, Second quarter

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Leslie A.

    1994-01-01

    This newsletter contains reprinted papers discussing technology options and associated measures for monitoring a Comprehensive Test Ban Treaty (CTBT). These papers were presented to the Conference on Disarmament (CD) in May and June 1994. An interagency Verification Monitoring Task Force developed the papers. The task force included participants from the Arms Control and Disarmament Agency, the Department of Defense, the Department of Energy, the Intelligence Community, the Department of Interior, and the Department of State. The purpose of this edition of Arms Control and Nonproliferation Technologies is to share these papers with the broad base of stakeholders in a CTBT and to facilitate future technology discussions. The papers in the first group discuss possible technology options for monitoring a CTBT in all environments (underground, underwater, atmosphere, and space). These technologies, along with on-site inspections, would facilitate CTBT monitoring by treaty participants. The papers in the second group present possible associated measures, e.g., information exchanges and transparency measures, that would build confidence among states participating in a CTBT.

  5. Evaluating and planning the radioactive waste options for dismantling the Tokamak Fusion Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Rule, K.; Scott, J.; Larson, S. [Princeton Plasma Physics Lab., NJ (United States)] [and others

    1995-12-31

    The Tokamak Fusion Test Reactor (TFTR) is a one-of-a kind tritium fusion research reactor, and is planned to be decommissioned within the next several years. This is the largest fusion reactor in the world and as a result of deuterium-tritum reactions is tritium contaminated and activated from 14 Mev neutrons. This presents many unusual challenges when dismantling, packaging and disposing its components and ancillary systems. Special containers are being designed to accommodate the vacuum vessel, neutral beams, and tritium delivery and processing systems. A team of experienced professionals performed a detailed field study to evaluate the requirements and appropriate methods for packaging the radioactive materials. This team focused on several current and innovative methods for waste minimization that provides the oppurtunmost cost effective manner to package and dispose of the waste. This study also produces a functional time-phased schedule which conjoins the waste volume, weight, costs and container requirements with the detailed project activity schedule for the entire project scope. This study and project will be the first demonstration of the decommissioning of a tritium fusion test reactor. The radioactive waste disposal aspects of this project are instrumental in demonstrating the viability of a fusion power reactor with regard to its environmental impact and ultimate success.

  6. Interpreting results of cluster surveys in emergency settings: is the LQAS test the best option?

    Directory of Open Access Journals (Sweden)

    Blanton Curtis

    2008-12-01

    Full Text Available Abstract Cluster surveys are commonly used in humanitarian emergencies to measure health and nutrition indicators. Deitchler et al. have proposed to use Lot Quality Assurance Sampling (LQAS hypothesis testing in cluster surveys to classify the prevalence of global acute malnutrition as exceeding or not exceeding the pre-established thresholds. Field practitioners and decision-makers must clearly understand the meaning and implications of using this test in interpreting survey results to make programmatic decisions. We demonstrate that the LQAS test–as proposed by Deitchler et al. – is prone to producing false-positive results and thus is likely to suggest interventions in situations where interventions may not be needed. As an alternative, to provide more useful information for decision-making, we suggest reporting the probability of an indicator's exceeding the threshold as a direct measure of "risk". Such probability can be easily determined in field settings by using a simple spreadsheet calculator. The "risk" of exceeding the threshold can then be considered in the context of other aggravating and protective factors to make informed programmatic decisions.

  7. Systematic testing of flood adaptation options in urban areas through simulations

    Science.gov (United States)

    Löwe, Roland; Urich, Christian; Sto. Domingo, Nina; Mark, Ole; Deletic, Ana; Arnbjerg-Nielsen, Karsten

    2016-04-01

    While models can quantify flood risk in great detail, the results are subject to a number of deep uncertainties. Climate dependent drivers such as sea level and rainfall intensities, population growth and economic development all have a strong influence on future flood risk, but future developments can only be estimated coarsely. In such a situation, robust decision making frameworks call for the systematic evaluation of mitigation measures against ensembles of potential futures. We have coupled the urban development software DAnCE4Water and the 1D-2D hydraulic simulation package MIKE FLOOD to create a framework that allows for such systematic evaluations, considering mitigation measures under a variety of climate futures and urban development scenarios. A wide spectrum of mitigation measures can be considered in this setup, ranging from structural measures such as modifications of the sewer network over local retention of rainwater and the modification of surface flow paths to policy measures such as restrictions on urban development in flood prone areas or master plans that encourage compact development. The setup was tested in a 300 ha residential catchment in Melbourne, Australia. The results clearly demonstrate the importance of considering a range of potential futures in the planning process. For example, local rainwater retention measures strongly reduce flood risk a scenario with moderate increase of rain intensities and moderate urban growth, but their performance strongly varies, yielding very little improvement in situations with pronounced climate change. The systematic testing of adaptation measures further allows for the identification of so-called adaptation tipping points, i.e. levels for the drivers of flood risk where the desired level of flood risk is exceeded despite the implementation of (a combination of) mitigation measures. Assuming a range of development rates for the drivers of flood risk, such tipping points can be translated into

  8. Preliminary Evaluation Of DWPF Impacts Of Boric Acid Use In Cesium Strip FOR SWPF And MCU

    International Nuclear Information System (INIS)

    Stone, M.

    2010-01-01

    A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system includes the option to replace the current dilute nitric acid strip solution with boric acid. To support this effort, the impact of using 0.01M, 0.1M, 0.25M and 0.5M boric acid in place of 0.001M nitric acid was evaluated for impacts on the DWPF facility. The evaluation only covered the impacts of boric acid in the strip effluent and does not address the other changes in solvents (i.e., the new extractant, called MaxCalix, or the new suppressor, guanidine). Boric acid additions may lead to increased hydrogen generation during the SRAT and SME cycles as well as change the rheological properties of the feed. The boron in the strip effluent will impact glass composition and could require each SME batch to be trimmed with boric acid to account for any changes in the boron from strip effluent additions. Addition of boron with the strip effluent will require changes in the frit composition and could lead to changes in melt behavior. The severity of the impacts from the boric acid additions is dependent on the amount of boric acid added by the strip effluent. The use of 0.1M or higher concentrations of boric acid in the strip effluent was found to significantly impact DWPF operations while the impact of 0.01M boric acid is expected to be relatively minor. Experimental testing is required to resolve the issues identified during the preliminary evaluation. The issues to be addressed by the testing are: (1) Impact on SRAT acid addition and hydrogen generation; (2) Impact on melter feed rheology; (3) Impact on glass composition control; (4) Impact on frit production; and (5) Impact on melter offgas. A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system includes the option to replace the

  9. Optimizing Oral Bioavailability in Drug Discovery: An Overview of Design and Testing Strategies and Formulation Options.

    Science.gov (United States)

    Aungst, Bruce J

    2017-04-01

    For discovery teams working toward new, orally administered therapeutic agents, one requirement is to attain adequate systemic exposure after oral dosing, which is best accomplished when oral bioavailability is optimized. This report summarizes the bioavailability challenges currently faced in drug discovery, and the design and testing methods and strategies currently utilized to address the challenges. Profiling of discovery compounds usually includes separate assessments of solubility, permeability, and susceptibility to first-pass metabolism, which are the 3 most likely contributors to incomplete oral bioavailability. An initial assessment of absorption potential may be made computationally, and high throughput in vitro assays are typically performed to prioritize compounds for in vivo studies. The initial pharmacokinetic study is a critical decision point in compound evaluation, and the importance of the effect the dosing vehicle or formulation can have on oral bioavailability, especially for poorly water soluble compounds, is emphasized. Dosing vehicles and bioavailability-enabling formulations that can be used for discovery and preclinical studies are described. Optimizing oral bioavailability within a chemical series or for a lead compound requires identification of the barrier limiting bioavailability, and methods used for this purpose are outlined. Finally, a few key guidelines are offered for consideration when facing the challenges of optimizing oral bioavailability in drug discovery. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  10. The 'KATOD-1' strip readout ASIC for cathode strip chamber

    International Nuclear Information System (INIS)

    Golutvin, I.A.; Gorbunov, N.V.; Karzhavin, V.Yu.; Khabarov, V.S.; Movchan, S.A.; Smolin, D.A.; Dvornikov, O.V.; Shumejko, N.M.; Chekhovskij, V.A.

    2001-01-01

    The 'KATOD-1', a 16-channels readout ASIC, has been designed to perform tests of P3 and P4 full-scale prototypes of the cathode strip chamber for the ME1/1 forward muon station of the Compact Muon Solenoid (CMS) experiment. The ASIC channel consists of two charge-sensitive preamplifiers, a three-stage shaper with cancellation, and an output driver. The ASIC is instrumented with control of gain, in the range of (-4.2 : +5.0) mV/fC, and control of output pulse-shape. The equivalent input noise is equal to 2400 e with the slope of 12 e/pF for detector capacity up to 200 pF. The peaking time is 100 ns for the chamber signal. The ASIC has been produced by a microwave Bi-jFET technology

  11. The "KATOD-1" Strip Readout ASIC for Cathode Strip Chamber

    CERN Document Server

    Golutvin, I A; Karjavin, V Yu; Khabarov, V S; Movchan, S A; Smolin, D A; Dvornikov, O V; Shumeiko, N M; Tchekhovski, V A

    2001-01-01

    The "KATOD-1", a 16-channels readout ASIC, has been designed to perform tests of P3 and P4 full-scale prototypes of the cathode strip chamber for the ME1/1 forward muon station of the Compact Muon Solenoid (CMS) experiment. The ASIC channel consists of two charge-sensitive preamplifiers, a three-stage shaper with tail cancellation, and an output driver. The ASIC is instrumented with control of gain, in the range of (-4.2\\div +5.0) mV/fC, and control of output pulse-shape. The equivalent input noise is equal to 2400 e with the slope of 12 e/pF for detector capacity up to 200 pF. The peaking time is 100 ns for the chamber signal. The ASIC has been produced by a microwave Bi-jFET technology.

  12. Strip casting apparatus and method

    Science.gov (United States)

    Williams, R.S.; Baker, D.F.

    1988-09-20

    Strip casting apparatus including a molten-metal-holding container and a nozzle to deposit molten metal onto a moving chill drum to directly cast continuous metallic strip. The nozzle body includes a slot bounded between a back and a front lip. The slot width exceeds about 20 times the gap distance between the nozzle and the chill drum surface. Preferably, the slot width exceeds 0.5 inch. This method of strip casting minimizes pressure drop, insuring better metal-to-chill-drum contact which promotes heat transfer and results in a better quality metallic strip. 6 figs.

  13. Rationalization and Student/School Personhood in U.S. College Admissions: The Rise of Test-Optional Policies, 1987 to 2015

    Science.gov (United States)

    Furuta, Jared

    2017-01-01

    This article examines the rise of "test-optional" college admissions policies since the 1990s. I argue that the rationalization of college admissions policies after World War II contributed to the rise of "meritocratic" stratification (in policy) and standardized tests, like the SAT, but it also led to the expansion and…

  14. Pilot-scale fluidized-bed combustor testing cofiring animal-tissue biomass with coal as a carcass disposal option

    Energy Technology Data Exchange (ETDEWEB)

    Bruce G. Miller; Sharon Falcone Miller; Elizabeth M. Fedorowicz; David W. Harlan; Linda A. Detwiler; Michelle L. Rossman [Pennsylvania State University, University Park, PA (United States). Energy Institute

    2006-10-15

    This study was performed to demonstrate the technical viability of cofiring animal-tissue biomass (ATB) in a coal-fired fluidized-bed combustor (FBC) as an option for disposing of specified risk materials (SRMs) and carcasses. The purpose of this study was to assess the technical issues of feeding/combusting ATB and not to investigate prion deactivation/pathogen destruction. Overall, the project successfully demonstrated that carcasses and SRMs can be cofired with coal in a bubbling FBC. Feeding ATB into the FBC did, however, present several challenges. Specifically, handling/feeding issues resulting from the small scale of the equipment and the extremely heterogeneous nature of the ATB were encountered during the testing. Feeder modifications and an overbed firing system were necessary. Through statistical analysis, it was shown that the ATB feed location had a greater effect on CO emissions, which were used as an indication of combustion performance, than the fuel type due to the feeding difficulties. Baseline coal tests and tests cofiring ATB into the bed were statistically indistinguishable. Fuel feeding issues would not be expected at the full scale since full-scale units routinely handle low-quality fuels. In a full-scale unit, the disproportionate ratio of feed line size to unit diameter would be eliminated thereby eliminating feed slugging. Also, the ATB would either be injected into the bed, thereby ensuring uniform mixing and complete combustion, or be injected directly above the bed with overfire air ports used to ensure complete combustion. Therefore, it is anticipated that a demonstration at the full scale, which is the next activity in demonstrating this concept, should be successful. As the statistical analysis shows, emissions cofiring ATB with coal would be expected to be similar to that when firing coal only. 14 refs., 5 figs., 6 tabs.

  15. Rehabilitation Options

    Science.gov (United States)

    ... Speech Pathology Occupational Therapy Art Therapy Recreational therapy Neuropsychology Home Care Options Advanced Care Planning Palliative Care ... Speech Pathology Occupational Therapy Art Therapy Recreational therapy Neuropsychology Home Care Options Advanced Care Planning Palliative Care ...

  16. Study the Z-Plane Strip Capacitance

    International Nuclear Information System (INIS)

    Parikh, H.; Swain, S.

    2005-01-01

    The BaBaR detector at the Stanford Linear Accelerator Center is currently undergoing an upgrade to improve its muon and neutral hadron detection system. The Resistive Plate Chambers (RPCs) that had been used till now have deteriorated in performance over the past few years and are being replaced by Limited Streamer Tube (LSTs). Each layer of the system consists of a set of up to 10 streamer tube modules which provide one coordinate (φ coordinate) and a single ''Z-plane'' which provides the Z coordinate of the hit. The large area Z-planes (up to 12m 2 ) are 1mm thick and contain 96 copper strips that detect the induced charge from avalanches created in the streamer tube wires. All the Z-planes needed for the upgrade have already been constructed, but only a third of the planes were installed last summer. After installing the 24 Z-planes last year, it was learned that 0.7% of the strips were dead when put inside the detector. This was mainly due to the delicate solder joint between the read-out cable and the strip, and since it is difficult to access or replace the Z-planes inside the detector, it is very important to perform various tests to make sure that the Z-planes will be efficient and effective in the long term. We measure the capacitance between the copper strips and the ground plane, and compare it to the theoretical value that we expect. Instead of measuring the capacitance channel by channel, which would be a very tedious job, we developed a more effective method of measuring the capacitance. Since all the Z-planes were built at SLAC, we also built a smaller 46 cm by 30 cm Z-plane with 12 strips just to see how they were constructed and to gain a better understanding about the solder joints

  17. Reliability-based econometrics of aerospace structural systems: Design criteria and test options. Ph.D. Thesis - Georgia Inst. of Tech.

    Science.gov (United States)

    Thomas, J. M.; Hanagud, S.

    1974-01-01

    The design criteria and test options for aerospace structural reliability were investigated. A decision methodology was developed for selecting a combination of structural tests and structural design factors. The decision method involves the use of Bayesian statistics and statistical decision theory. Procedures are discussed for obtaining and updating data-based probabilistic strength distributions for aerospace structures when test information is available and for obtaining subjective distributions when data are not available. The techniques used in developing the distributions are explained.

  18. Dynamic underground stripping demonstration project

    International Nuclear Information System (INIS)

    Newmark, R.L.

    1992-04-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation techniques for rapid cleanup of localized underground spills. Called dynamic stripping to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first eight months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques. Tests then began on the contaminated site in FY 1992. This report describes the work at the Clean Site, including design and performance criteria, test results, interpretations, and conclusions. We fielded 'a wide range of new designs and techniques, some successful and some not. In this document, we focus on results and performance, lessons learned, and design and operational changes recommended for work at the contaminated site. Each section focuses on a different aspect of the work and can be considered a self-contained contribution

  19. Dual deflectable beam strip engine development.

    Science.gov (United States)

    Dulgeroff, C. R.; Zuccaro, D. E.; Kami, S.; Schnelker, D. E.; Ward, J. W.

    1972-01-01

    This paper describes a dual beam thruster that has been designed, constructed, and tested. The system is suitable for two-axes attitude control and is comprised of two orthogonal strips, each capable of producing 0.30 mlb thrust and beam deflections of more than plus or minus 20 deg. The nominal specific impulse for the thruster is 5000 sec, and the thrust level from each strip can be varied from 0 to 100%. Neutralizer filaments that were developed and life tested over 2000 hours producing more than 40 mA of electron emission per watt of input power are also discussed. The system power required for clean ionizers is approximately 200 W.

  20. Cathode readout with stripped resistive drift tubes

    International Nuclear Information System (INIS)

    Bychkov, V.N.; Kekelidze, G.D.; Novikov, E.A.; Peshekhonov, V.D.; Shafranov, M.D.; Zhiltsov, V.E.

    1995-01-01

    A straw tube drift chamber prototype has been constructed and tested. The straw tube material is mylar film covered with a carbon layer with a resistivity of 0.5, 30 and 70 kΩ/□. Both the anode wire and the cathode strip signals were detected to study the behaviour of the chamber in the presence of X-ray ionization. The construction and the results of the study are presented. (orig.)

  1. Cathode readout with stripped resistive drift tubes

    Science.gov (United States)

    Bychkov, V. N.; Kekelidze, G. D.; Novikov, E. A.; Peshekhonov, V. D.; Shafranov, M. D.; Zhiltsov, V. E.

    1995-12-01

    A straw tube drift chamber prototype has been constructed and tested. The straw tube material is mylar film covered with a carbon layer with a resistivity of 0.5, 30 and 70 kΩ/□. Both the anode wire and the cathode strip signals were detected to study the behaviour of the chamber in the presence of X-ray ionization. The construction and the results of the study are presented.

  2. Clinical Decision Support and Optional Point of Care Testing of Renal Function for Safe Use of Antibiotics in Elderly Patients : A Retrospective Study in Community Pharmacy Practice

    NARCIS (Netherlands)

    Heringa, Mette; Floor-Schreudering, Annemieke; De Smet, Peter A G M; Bouvy, Marcel L

    2017-01-01

    OBJECTIVE: The aim was to investigate the management of drug therapy alerts on safe use of antibiotics in elderly patients with (potential) renal impairment and the contribution of optional creatinine point of care testing (PoCT) in community pharmacy practice. METHODS: Community pharmacists used a

  3. ACCOUNTING FOR OPTIONS AND ANALYSIS OF USE OF OPTION COMBINATION STRATEGIES

    Directory of Open Access Journals (Sweden)

    I. Derun

    2016-08-01

    Full Text Available The article deals with problems of accounting for options in Ukraine, namely: value expression of initial cost of options, their revaluation, accounting of premiums, financial assets and financial liabilities and variation margin. The paper offers ways of solution of these problems which based on harmonization with IAS 32, IAS 39, IFRS 7 and IFRS 9. The study considers option combination strategies (straddle, strangle, strap, strip and approaches of identification of possible financial results for investors which use these strategies. Examples of possible financial results are provided for buyers and sellers of options which use option combination strategies.

  4. Characterization of galvannealed strip

    International Nuclear Information System (INIS)

    Moreas, G.; Hardy, Y.

    1999-01-01

    With the aim of enhancing coating quality control during galvannealing process, an online microscopic image acquisition sensor has been developed at CRM. In galvannealing process, the ζ phase surface density is a coating quality characteristic, and the on-line microscope, equipped with optics placed at 20 mm from the surface, grabs 250 μm x 190 μm images on which ζ crystals (approximate dimensions: 1 μm x 10 μm) can be clearly identified. On-line, the sensor is mounted in front of a roll where the strip has a stable position. The coating surface to sensor optics distance is continuously measured by an accurate triangulation sensor (1 μm repeatability) and is adjusted in such a way that, due to roll eccentricity, the image is focused at least twice per revolution. When focused, image of moving product is frozen by a short (10 ns) laser light pulse and is grabbed. The obtained image is then processed to extract ζ phase percentage and allows adjustment of process parameters to reach the desired coating characteristics. (author)

  5. Buffers and vegetative filter strips

    Science.gov (United States)

    Matthew J. Helmers; Thomas M. Isenhart; Michael G. Dosskey; Seth M. Dabney

    2008-01-01

    This chapter describes the use of buffers and vegetative filter strips relative to water quality. In particular, we primarily discuss the herbaceous components of the following NRCS Conservation Practice Standards.

  6. Strip-till seeder for sugar beets

    Directory of Open Access Journals (Sweden)

    Peter Schulze Lammers

    2014-06-01

    Full Text Available Strip-till save costs by reducing tillage on the area of sugar beet rows only. The seeding system is characterized by a deep loosening of soil with a tine combined with a share and by following tools generating fine-grained soil as seed bed. In cooperation with the Kverneland company group Soest/Germany a strip tiller combined with precision seeder was designed and tested in field experiments. Tilling and seeding was performed in one path on fields with straw and mustard mulch. Even the plant development was slower as compared to conventional sawn sugar beets the yield was on equivalent level. Further field experiments are planned to attest constant yield, cost and energy efficiency of the seeding system.

  7. Magnetic stripping studies for SPL

    CERN Document Server

    Posocco, P; CERN. Geneva. BE Department

    2010-01-01

    Magnetic stripping of H- can seriously enhance the beam losses along the SPL machine. These losses depend on the beam energy, on the beam transverse distribution and on the intensity of the magnetic field. For radioprotection issues the losses must be limited to 1 W/m. In this paper we will concentrate on the stripping phenomena inside the quadrupole magnets with the aim of defining the quadrupole range for the design phase of SPL.

  8. An updated dose assessment for resettlement options at Bikini Atoll--a U.S. nuclear test site.

    Science.gov (United States)

    Robison, W L; Bogen, K T; Conrado, C L

    1997-07-01

    On 1 March 1954, a nuclear weapon test, code-named BRAVO, conducted at Bikini Atoll in the northern Marshall Islands contaminated the major residence island. There has been a continuing effort since 1977 to refine dose assessments for resettlement options at Bikini Atoll. Here we provide a radiological dose assessment for the main residence island, Bikini, using extensive radionuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island as part of our continuing research and monitoring program that began in 1978. The unique composition of coral soil greatly alters the relative contribution of 137Cs and 90Sr to the total estimated dose relative to expectations based on North American and European soils. Without counter measures, 137Cs produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The doses are calculated assuming a resettlement date of 1999. The estimated maximum annual effective dose for current island conditions is 4.0 mSv when imported foods, which are now an established part of the diet, are available. The 30-, 50-, and 70-y integral effective doses are 91 mSv, 130 mSv, and 150 mSv, respectively. A detailed uncertainty analysis for these dose estimates is presented in a companion paper in this issue. We have evaluated various countermeasures to reduce 137Cs in food crops. Treatment with potassium reduces the uptake of 137Cs into food crops, and therefore the ingestion dose, to about 5% of pretreatment levels and has essentially no negative environmental consequences. We have calculated the dose for the rehabilitation scenario where the top 40 cm of soil is removed in the housing and village area, and the rest of the island is treated with potassium fertilizer; the maximum annual effective dose is 0.41 mSv and the 30-, 50-, and 70-y

  9. Typhoid fever in a Tertiary Hospital in Nigeria: Another look at the Widal agglutination test as a preferred option for diagnosis.

    Science.gov (United States)

    Enabulele, Osahon; Awunor, Simeon Nyemike

    2016-01-01

    Single Widal agglutination test rather than blood culture, is commonly employed to diagnose typhoid fever in Nigeria. We took another look at the Widal agglutination test as a preferred option for diagnosis of typhoid fever by determining the specificity and sensitivity of Widal agglutination test in febrile adult patients. Two hundred and seventy-one blood samples from consecutive adults (>18 years) with febrile illness attending the General Practice Clinic of the University of Benin Teaching Hospital were tested using the Widal agglutination test, blood culture, and malaria parasite test on each sample to establish the diagnosis of typhoid fever. Of the 271 blood samples 124 (45.76%) were positive following a Widal agglutination test, 60 (22.10%) blood samples grew Salmonella organisms on blood culture while 55 (20.29%) blood samples showed a co-infection of typhoid fever and malaria. A sensitivity of 35%, specificity of 51%, positive predictive value of 17%, and a negative predictive value of 73% were observed for Widal agglutination test as a diagnostic modality for typhoid fever infection. A single Widal agglutination test is not a valid diagnostic option for typhoid fever while co-infection with malaria parasite is the preponderant microbiological finding in typhoid fever infections. The severity of malaria parasitemia is associated with positive titers on Widal test.

  10. Effect of response format on cognitive reflection: Validating a two- and four-option multiple choice question version of the Cognitive Reflection Test.

    Science.gov (United States)

    Sirota, Miroslav; Juanchich, Marie

    2018-03-27

    The Cognitive Reflection Test, measuring intuition inhibition and cognitive reflection, has become extremely popular because it reliably predicts reasoning performance, decision-making, and beliefs. Across studies, the response format of CRT items sometimes differs, based on the assumed construct equivalence of tests with open-ended versus multiple-choice items (the equivalence hypothesis). Evidence and theoretical reasons, however, suggest that the cognitive processes measured by these response formats and their associated performances might differ (the nonequivalence hypothesis). We tested the two hypotheses experimentally by assessing the performance in tests with different response formats and by comparing their predictive and construct validity. In a between-subjects experiment (n = 452), participants answered stem-equivalent CRT items in an open-ended, a two-option, or a four-option response format and then completed tasks on belief bias, denominator neglect, and paranormal beliefs (benchmark indicators of predictive validity), as well as on actively open-minded thinking and numeracy (benchmark indicators of construct validity). We found no significant differences between the three response formats in the numbers of correct responses, the numbers of intuitive responses (with the exception of the two-option version, which had a higher number than the other tests), and the correlational patterns of the indicators of predictive and construct validity. All three test versions were similarly reliable, but the multiple-choice formats were completed more quickly. We speculate that the specific nature of the CRT items helps build construct equivalence among the different response formats. We recommend using the validated multiple-choice version of the CRT presented here, particularly the four-option CRT, for practical and methodological reasons. Supplementary materials and data are available at https://osf.io/mzhyc/ .

  11. Tritium stripping by a catalytic exchange stripper

    International Nuclear Information System (INIS)

    Heung, L.K.; Gibson, G.W.; Ortman, M.S.

    1991-01-01

    A catalytic exchange process for stripping elemental tritium from gas streams has been demonstrated. The process uses a catalyzed isotopic exchange reaction between tritium in the gas phase and protium or deuterium in the solid phase on alumina. The reaction is catalyzed by platinum deposited on the alumina. The process has been tested with both tritium and deuterium. Decontamination factors (ration of inlet and outlet tritium concentrations) as high as 1000 have been achieved, depending on inlet concentration. The test results and some demonstrated applications are presented

  12. HIV testing uptake and retention in care of HIV-infected pregnant and breastfeeding women initiated on 'Option B+' in rural Zimbabwe.

    Science.gov (United States)

    Dzangare, Janet; Takarinda, Kudakwashe C; Harries, Anthony D; Tayler-Smith, Katie; Mhangara, Mutsa; Apollo, Tsitsi Mutasa; Mushavi, Angela; Chimwaza, Anesu; Sithole, Ngwarai; Magure, Tapiwa; Mpofu, Amon; Dube, Freeman; Mugurungi, Owen

    2016-02-01

    Zimbabwe has started to scale up Option B+ for the prevention of mother-to-child transmission of HIV, but there is little published information about uptake or retention in care. This study determined the number and proportion of pregnant and lactating women in rural districts diagnosed with HIV infection and started on Option B+ along with six-month antiretroviral treatment (ART) outcomes. This was a retrospective record review of women presenting to antenatal care or maternal and child health services at 34 health facilities in Chikomba and Gutu rural districts, Zimbabwe, between January and March 2014. A total of 2728 women presented to care of whom 2598 were eligible for HIV testing: 76% presented to antenatal care, 20% during labour and delivery and 4% while breastfeeding. Of 2097 (81%) HIV-tested women, 7% were HIV positive. Lower HIV testing uptake was found with increasing parity, late presentation to antenatal care, health centre attendance and in women tested during labour. Ninety-one per cent of the HIV-positive women were started on Option B+. Six-month ART retention in care, including transfers, was 83%. Loss to follow-up was the main cause of attrition. Increasing age and gravida status ≥2 were associated with higher six-month attrition. The uptake of HIV testing and Option B+ is high in women attending antenatal and post-natal clinics in rural Zimbabwe, suggesting that the strategy is feasible for national scale-up in the country. © 2015 John Wiley & Sons Ltd.

  13. Budget Options

    National Research Council Canada - National Science Library

    2000-01-01

    This volume-part of the Congressional Budget Office's (CBO's) annual report to the House and Senate Committees on the Budget-is intended to help inform policymakers about options for the federal budget...

  14. Rapid clearance of Schistosoma mansoni circulating cathodic antigen after treatment shown by urine strip tests in a Ugandan fishing community 

    DEFF Research Database (Denmark)

    Kildemoes, Anna O.; Vennervald, Birgitte J.; Tukahebwa, Edridah M.

    2017-01-01

    treatments. The study was designed as a series of cross-sectional urine and stool sample collections from 446 individuals nested in a two-arm randomised single blinded longitudinal clinical trial cohort matched by gender and age (ClinicalTrials.gov Identifier: NCT00215267) receiving one or two praziquantel...... and confirmed the added beneficial effect of a second treatment at two weeks after baseline. Furthermore, presence of hookworm was found not to be a confounder for CCA test specificity. Twenty-four hours post treatment measures of mean CCA scores showed significant reductions. In conclusion, removal of CCA...... in response to treatment is detectable as a decline in CCA in urine already after 24 hours. This has relevance for use and interpretation of laboratory based and point-of-care CCA tests in terms of treatment efficacy and re-infection proportions as this measure provides information on the presence of all...

  15. Properties of a six-gap timing resistive plate chamber with strip readout

    International Nuclear Information System (INIS)

    Ammosov, V.V.; Gapienko, V.A.; Semak, A.A.; Sviridov, Yu.M.; Zaets, V.G.; Gavrishchuk, O.P.; Kuz'min, N.A.; Sychkov, S.Ya.; Usenko, E.A.; Yukaev, A.I.

    2009-01-01

    Six-gap glass timing resistive plate chamber with strip readout was tested using IHEP U-70 PS test beam. The time resolution of ∼ 45 ps at efficiency larger than 98% was achieved. Position resolution along strip was estimated to be ∼1 cm

  16. Magnetic ring for stripping enhancement

    International Nuclear Information System (INIS)

    Selph, F.

    1992-10-01

    A ring designed to recycle ions through a stripping medium offers the possibility for increasing output of the desired charge state by up to 4x. This could be a very important component of a Radioactive Nuclear Beam Facility. In order for such a ring to work effectively it must satisfy certain design conditions. These include achromaticity at the stripper, a dispersed region for an extraction magnet, and a number of first and higher order optics constraints which are necessary to insure that the beam emittance is not degraded unduly by the ring. An example is given of a candidate design of a stripping ring

  17. First results from a silicon-strip detector with VLSI readout

    International Nuclear Information System (INIS)

    Anzivino, G.; Horisberger, R.; Hubbeling, L.; Hyams, B.; Parker, S.; Breakstone, A.; Litke, A.M.; Walker, J.T.; Bingefors, N.

    1986-01-01

    A 256-strip silicon detector with 25 μm strip pitch, connected to two 128-channel NMOS VLSI chips (Microplex), has been tested using straight-through tracks from a ruthenium beta source. The readout channels have a pitch of 47.5 μm. A single multiplexed output provides voltages proportional to the integrated charge from each strip. The most probable signal height from the beta traversals is approximately 14 times the rms noise in any single channel. (orig.)

  18. Outfall 51 air stripping feasibility study for the Reduction of Mercury in Plant Effluent (RMPE) Project. Revision 1

    International Nuclear Information System (INIS)

    1997-01-01

    Within the US Department of Energy's Oak Ridge Y-12 Plant there are a number of industrial wastewater discharge points or outfalls that empty into East Fork Poplar Creek (EFPC). EFPC originates within and runs continuously throughout the plant site and subsequently flows out the east end of the Y-12 Plant into the City of Oak Ridge. Mercury is present in outfall discharges due to contact of water with the soils surrounding past mercury-use buildings. As a result, the Reduction of Mercury in Plant Effluent (RMPE) Project was developed to achieve and maintain environmental compliance with regards to mercury, and, in particular with the National Pollutant Discharge Elimination System permit for the Y-12 Plant. To achieve a reduction in mercury loading to EFPC, a number of options have already been studied and implemented as part of the RMPE project. With the successful implementation of these options, Outfall 51 remains as a significant contributor to mercury load to EFPC. The primary purpose of this project is to determine the feasibility of removing mercury from contaminated spring water using air stripping. In order to accomplish this goal, a number of different areas were addressed. A pilot-scale unit was tested in the field using actual mercury-contaminated source water. Properties which impact the mercury removal via air stripping were reviewed to determine their effect. Also, enhanced testing was performed to improve removal efficiencies. Finally, the variable outfall flow was studied to size appropriate processing equipment for full-scale treatment

  19. Process Simulation Analysis of HF Stripping

    Directory of Open Access Journals (Sweden)

    Thaer A. Abdulla

    2015-02-01

    Full Text Available    HYSYS process simulator is used for the analysis of existing HF stripping column in LAB plant (Arab Detergent Company, Baiji-Iraq. Simulated column performance and profiles curves are constructed. The variables considered are the thermodynamic model option, bottom temperature, feed temperature, and column profiles for the temperature, vapor flow rate, liquid flow rate and composition. The five thermodynamic models options used (Margules, UNIQUAC, van laar, Antoine, and Zudkevitch-Joffee, affecting the results within (0.1-58% variation for the most cases.        The simulated results show that about 4% of paraffin (C10 & C11 presents at the top stream, which may cause a problem in the LAB production plant. The major variations were noticed for the total top vapor flow rate with bottom temperature and with feed composition. The column profiles maintain fairly constants from tray 5 to tray 18. The study gives evidence about a successful simulation with HYSYS because the results correspond with the real plant operation data.

  20. Validity of HydraTrend reagent strips for the assessment of hydration status.

    Science.gov (United States)

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  1. Axial Fatigue Tests at Zero Mean Stress of 24S-T and 75S-T Aluminum-alloy Strips with a Central Circular Hole

    Science.gov (United States)

    Brueggeman, W C; Mayer, M JR

    1948-01-01

    Axial fatigue tests at zero mean stress have been made on 0.032- and 0.064-inch 24S-T and 0.032-inch 75S-T sheet-metal specimens 1/4, 1/2, 1, and 2 inches wide without a hole and with central holes giving a range of hole diameter D to specimen width W from 0.01 to 0.95. No systematic difference was noted between the results for the 0.032-inch and the 0.064-inch specimens although the latter seemed the more consistent. In general the fatigue strength based on the minimum section dropped sharply as the ration D/W was increased from zero to about 0.25. The plain specimens showed quite a pronounced decrease in fatigue strength with increasing width. The holed specimens showed only slight and rather inconclusive evidence of this size effect. The fatigue stress-concentration factor was higher for 75S-T than for 24S-T alloy. Evidence was found that a very small hole would not cause any reduction in fatigue strength.

  2. ‘Much clearer with pictures’: using community-based participatory research to design and test a Picture Option Grid for underserved patients with breast cancer

    Science.gov (United States)

    Durand, Marie-Anne; Alam, Shama; Grande, Stuart W; Elwyn, Glyn

    2016-01-01

    Objective Women of low socioeconomic status (SES) diagnosed with early stage breast cancer experience decision-making, treatment and outcome disparities. Evidence suggests that decision aids can benefit underserved patients, when tailored to their needs. Our aim was to develop and test the usability, acceptability and accessibility of a pictorial encounter decision aid targeted at women of low SES diagnosed with early stage breast cancer. Design Community-based participatory research (CBPR) using think-aloud protocols (phases 1 and 2) and semistructured interviews (phase 3). Setting Underserved community settings (eg, knitting groups, bingo halls, senior centres) and breast clinics. Participants In phase 1, we recruited a convenience sample of clinicians and academics. In phase 2, we targeted women over 40 years of age, of low SES, regardless of breast cancer history, and in phase 3, women of low SES, recently diagnosed with breast cancer. Intervention The pictorial encounter decision aid was derived from an evidence-based table comparing treatment options for breast cancer (http://www.optiongrid.org). Outcome measures We assessed the usability, acceptability and accessibility of the pictorial decision aid prototypes using the think-aloud protocol and semistructured interviews. Results After initial testing of the first prototype with 18 academics and health professionals, new versions were developed and tested with 53 lay individuals in community settings. Usability was high. In response to feedback indicating that the use of cartoon characters was considered insensitive, a picture-only version was developed and tested with 23 lay people in phase 2, and 10 target users in phase 3. Conclusions and relevance Using CBPR methods and iterative user testing cycles improved usability and accessibility, and led to the development of the Picture Option Grid, entirely guided by multiple stakeholder feedback. All women of low SES recently diagnosed with early stage breast

  3. Evaluation of Moisture Damage and Stripping of Asphalt Concrete Prepared With New Additives of Polymer Modified Bitumen

    Directory of Open Access Journals (Sweden)

    Basim H. Al-Humeidawi

    2016-03-01

    Full Text Available The moisture induced damage and stripping are two of common reasons of premature failure of flexible pavement. The current research involved an extensive experimental investigation on two types of polymers (Novolac and PVA as modifiers in order to produce Polymer Modified Bitumen (PMB. Different ratios of both additives were investigated for rheological properties of binder and mechanical properties of Hot Mix Asphalt (HMA. The rheological properties of PMB were evaluated by penetration, softening point, ductility and thin film oven tests. The mechanical properties of HMA were assessed by Marshall Stability test, Retained Marshall Stability test, indirect tensile strength test, Tensile Strength Ratio (TSR, and striping test. The results of tests showed that the Novolac modifier improves the cohesion properties of binder and the adhesion of binder to aggregate. The PVA modifier mainly improves the adhesion of binder to aggregate with less degree of that of using Novolac. Both modifiers significantly improve moisture sensitivity and decrease the stripping of HMA. Also, the results showed that the addition of 2% of Novolac to binder to produce PMB represents the optimum option. The HMA with PMB Novolac 2% improves the Marshall Stability, Retained Marshall Stability, and TSR by 45%, 14% and 44% respectively. The very small amount of these additives compared with mix components and their reasonable price make them a superior and practical solution for premature failure of flexible pavement.

  4. Performance studies of the CMS Strip Tracker before installation

    CERN Document Server

    Adam, Wolfgang; Dragicevic, Marko; Friedl, Markus; Fruhwirth, R; Hansel, S; Hrubec, Josef; Krammer, Manfred; Oberegger, Margit; Pernicka, Manfred; Schmid, Siegfried; Stark, Roland; Steininger, Helmut; Uhl, Dieter; Waltenberger, Wolfgang; Widl, Edmund; Van Mechelen, Pierre; Cardaci, Marco; Beaumont, Willem; de Langhe, Eric; de Wolf, Eddi A; Delmeire, Evelyne; Hashemi, Majid; Bouhali, Othmane; Charaf, Otman; Clerbaux, Barbara; Dewulf, Jean-Paul; Elgammal, Sherif; Hammad, Gregory Habib; de Lentdecker, Gilles; Marage, Pierre Edouard; Vander Velde, Catherine; Vanlaer, Pascal; Wickens, John; Adler, Volker; Devroede, Olivier; De Weirdt, Stijn; D'Hondt, Jorgen; Goorens, Robert; Heyninck, Jan; Maes, Joris; Mozer, Matthias Ulrich; Tavernier, Stefaan; Van Lancker, Luc; Van Mulders, Petra; Villella, Ilaria; Wastiels, C; Bonnet, Jean-Luc; Bruno, Giacomo; De Callatay, Bernard; Florins, Benoit; Giammanco, Andrea; Gregoire, Ghislain; Keutgen, Thomas; Kcira, Dorian; Lemaitre, Vincent; Michotte, Daniel; Militaru, Otilia; Piotrzkowski, Krzysztof; Quertermont, L; Roberfroid, Vincent; Rouby, Xavier; Teyssier, Daniel; Daubie, Evelyne; Anttila, Erkki; Czellar, Sandor; Engstrom, Pauli; Harkonen, J; Karimaki, V; Kostesmaa, J; Kuronen, Auli; Lampen, Tapio; Linden, Tomas; Luukka, Panja-Riina; Maenpaa, T; Michal, Sebastien; Tuominen, Eija; Tuominiemi, Jorma; Ageron, Michel; Baulieu, Guillaume; Bonnevaux, Alain; Boudoul, Gaelle; Chabanat, Eric; Chabert, Eric Christian; Chierici, Roberto; Contardo, Didier; Della Negra, Rodolphe; Dupasquier, Thierry; Gelin, Georges; Giraud, Noël; Guillot, Gérard; Estre, Nicolas; Haroutunian, Roger; Lumb, Nicholas; Perries, Stephane; Schirra, Florent; Trocme, Benjamin; Vanzetto, Sylvain; Agram, Jean-Laurent; Blaes, Reiner; Drouhin, Frédéric; Ernenwein, Jean-Pierre; Fontaine, Jean-Charles; Berst, Jean-Daniel; Brom, Jean-Marie; Didierjean, Francois; Goerlach, Ulrich; Graehling, Philippe; Gross, Laurent; Hosselet, J; Juillot, Pierre; Lounis, Abdenour; Maazouzi, Chaker; Olivetto, Christian; Strub, Roger; Van Hove, Pierre; Anagnostou, Georgios; Brauer, Richard; Esser, Hans; Feld, Lutz; Karpinski, Waclaw; Klein, Katja; Kukulies, Christoph; Olzem, Jan; Ostapchuk, Andrey; Pandoulas, Demetrios; Pierschel, Gerhard; Raupach, Frank; Schael, Stefan; Schwering, Georg; Sprenger, Daniel; Thomas, Maarten; Weber, Markus; Wittmer, Bruno; Wlochal, Michael; Beissel, Franz; Bock, E; Flugge, G; Gillissen, C; Hermanns, Thomas; Heydhausen, Dirk; Jahn, Dieter; Kaussen, Gordon; Linn, Alexander; Perchalla, Lars; Poettgens, Michael; Pooth, Oliver; Stahl, Achim; Zoeller, Marc Henning; Buhmann, Peter; Butz, Erik; Flucke, Gero; Hamdorf, Richard Helmut; Hauk, Johannes; Klanner, Robert; Pein, Uwe; Schleper, Peter; Steinbruck, G; Blum, P; De Boer, Wim; Dierlamm, Alexander; Dirkes, Guido; Fahrer, Manuel; Frey, Martin; Furgeri, Alexander; Hartmann, Frank; Heier, Stefan; Hoffmann, Karl-Heinz; Kaminski, Jochen; Ledermann, Bernhard; Liamsuwan, Thiansin; Muller, S; Muller, Th; Schilling, Frank-Peter; Simonis, Hans-Jürgen; Steck, Pia; Zhukov, Valery; Cariola, P; De Robertis, Giuseppe; Ferorelli, Raffaele; Fiore, Luigi; Preda, M; Sala, Giuliano; Silvestris, Lucia; Tempesta, Paolo; Zito, Giuseppe; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Giordano, Domenico; Maggi, Giorgio; Manna, Norman; My, Salvatore; Selvaggi, Giovanna; Albergo, Sebastiano; Chiorboli, Massimiliano; Costa, Salvatore; Galanti, Mario; Giudice, Nunzio; Guardone, Nunzio; Noto, Francesco; Potenza, Renato; Saizu, Mirela Angela; Sparti, V; Sutera, Concetta; Tricomi, Alessia; Tuve, Cristina; Brianzi, Mirko; Civinini, Carlo; Maletta, Fernando; Manolescu, Florentina; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Broccolo, B; Ciulli, Vitaliano; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Genta, Chiara; Landi, Gregorio; Lenzi, Piergiulio; Macchiolo, Anna; Magini, Nicolo; Parrini, Giuliano; Scarlini, Enrico; Cerati, Giuseppe Benedetto; Azzi, Patrizia; Bacchetta, Nicola; Candelori, Andrea; Dorigo, Tommaso; Kaminsky, A; Karaevski, S; Khomenkov, Volodymyr; Reznikov, Sergey; Tessaro, Mario; Bisello, Dario; De Mattia, Marco; Giubilato, Piero; Loreti, Maurizio; Mattiazzo, Serena; Nigro, Massimo; Paccagnella, Alessandro; Pantano, Devis; Pozzobon, Nicola; Tosi, Mia; Bilei, Gian Mario; Checcucci, Bruno; Fano, Livio; Servoli, Leonello; Ambroglini, Filippo; Babucci, Ezio; Benedetti, Daniele; Biasini, Maurizio; Caponeri, Benedetta; Covarelli, Roberto; Giorgi, Marco; Lariccia, Paolo; Mantovani, Giancarlo; Marcantonini, Marta; Postolache, Vasile; Santocchia, Attilio; Spiga, Daniele; Bagliesi, Giuseppe; Balestri, Gabriele; Berretta, Luca; Bianucci, S; Boccali, Tommaso; Bosi, Filippo; Bracci, Fabrizio; Castaldi, Rino; Ceccanti, Marco; Cecchi, Roberto; Cerri, Claudio; Cucoanes, Andi Sebastian; Dell'Orso, Roberto; Dobur, Didar; Dutta, Suchandra; Giassi, Alessandro; Giusti, Simone; Kartashov, Dmitry; Kraan, Aafke; Lomtadze, Teimuraz; Lungu, George-Adrian; Magazzu, Guido; Mammini, Paolo; Mariani, Filippo; Martinelli, Giovanni; Moggi, Andrea; Palla, Fabrizio; Palmonari, Francesco; Petragnani, Giulio; Profeti, Alessandro; Raffaelli, Fabrizio; Rizzi, Domenico; Sanguinetti, Giulio; Sarkar, Subir; Sentenac, Daniel; Serban, Alin Titus; Slav, Adrian; Soldani, A; Spagnolo, Paolo; Tenchini, Roberto; Tolaini, Sergio; Venturi, Andrea; Verdini, Piero Giorgio; Vos, Marcel; Zaccarelli, Luciano; Avanzini, Carlo; Basti, Andrea; Benucci, Leonardo; Bocci, Andrea; Cazzola, Ugo; Fiori, Francesco; Linari, Stefano; Massa, Maurizio; Messineo, Alberto; Segneri, Gabriele; Tonelli, Guido; Azzurri, Paolo; Bernardini, Jacopo; Borrello, Laura; Calzolari, Federico; Foa, Lorenzo; Gennai, Simone; Ligabue, Franco; Petrucciani, Giovanni; Rizzi, Andrea; Yang, Zong-Chang; Benotto, Franco; Demaria, Natale; Dumitrache, Floarea; Farano, R; Borgia, Maria Assunta; Castello, Roberto; Costa, Marco; Migliore, Ernesto; Romero, Alessandra; Abbaneo, Duccio; Abbas, M; Ahmed, Ijaz; Akhtar, I; Albert, Eric; Bloch, Christoph; Breuker, Horst; Butt, Shahid Aleem; Buchmuller, Oliver; Cattai, Ariella; Delaere, Christophe; Delattre, Michel; Edera, Laura Maria; Engstrom, Pauli; Eppard, Michael; Gateau, Maryline; Gill, Karl; Giolo-Nicollerat, Anne-Sylvie; Grabit, Robert; Honma, Alan; Huhtinen, Mika; Kloukinas, Kostas; Kortesmaa, Jarmo; Kottelat, Luc-Joseph; Kuronen, Auli; Leonardo, Nuno; Ljuslin, Christer; Mannelli, Marcello; Masetti, Lorenzo; Marchioro, Alessandro; Mersi, Stefano; Michal, Sebastien; Mirabito, Laurent; Muffat-Joly, Jeannine; Onnela, Antti; Paillard, Christian; Pal, Imre; Pernot, Jean-Francois; Petagna, Paolo; Petit, Patrick; Piccut, C; Pioppi, Michele; Postema, Hans; Ranieri, Riccardo; Ricci, Daniel; Rolandi, Gigi; Ronga, Frederic Jean; Sigaud, Christophe; Syed, A; Siegrist, Patrice; Tropea, Paola; Troska, Jan; Tsirou, Andromachi; Vander Donckt, Muriel; Vasey, François; Alagoz, Enver; Amsler, Claude; Chiochia, Vincenzo; Regenfus, Christian; Robmann, Peter; Rochet, Jacky; Rommerskirchen, Tanja; Schmidt, Alexander; Steiner, Stefan; Wilke, Lotte; Church, Ivan; Cole, Joanne; Coughlan, John A; Gay, Arnaud; Taghavi, S; Tomalin, Ian R; Bainbridge, Robert; Cripps, Nicholas; Fulcher, Jonathan; Hall, Geoffrey; Noy, Matthew; Pesaresi, Mark; Radicci, Valeria; Raymond, David Mark; Sharp, Peter; Stoye, Markus; Wingham, Matthew; Zorba, Osman; Goitom, Israel; Hobson, Peter R; Reid, Ivan; Teodorescu, Liliana; Hanson, Gail; Jeng, Geng-Yuan; Liu, Haidong; Pasztor, Gabriella; Satpathy, Asish; Stringer, Robert; Mangano, Boris; Affolder, K; Affolder, T; Allen, Andrea; Barge, Derek; Burke, Samuel; Callahan, D; Campagnari, Claudio; Crook, A; D'Alfonso, Mariarosaria; Dietch, J; Garberson, Jeffrey; Hale, David; Incandela, H; Incandela, Joe; Jaditz, Stephen; Kalavase, Puneeth; Kreyer, Steven Lawrence; Kyre, Susanne; Lamb, James; Mc Guinness, C; Mills, C; Nguyen, Harold; Nikolic, Milan; Lowette, Steven; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rubinstein, Noah; Sanhueza, S; Shah, Yousaf Syed; Simms, L; Staszak, D; Stoner, J; Stuart, David; Swain, Sanjay Kumar; Vlimant, Jean-Roch; White, Dean; Ulmer, Keith; Wagner, Stephen Robert; Bagby, Linda; Bhat, Pushpalatha C; Burkett, Kevin; Cihangir, Selcuk; Gutsche, Oliver; Jensen, Hans; Johnson, Mark; Luzhetskiy, Nikolay; Mason, David; Miao, Ting; Moccia, Stefano; Noeding, Carsten; Ronzhin, Anatoly; Skup, Ewa; Spalding, William J; Spiegel, Leonard; Tkaczyk, Slawek; Yumiceva, Francisco; Zatserklyaniy, Andriy; Zerev, E; Anghel, Ioana Maria; Bazterra, Victor Eduardo; Gerber, Cecilia Elena; Khalatian, S; Shabalina, Elizaveta; Baringer, Philip; Bean, Alice; Chen, Jie; Hinchey, Carl Louis; Martin, Christophe; Moulik, Tania; Robinson, Richard; Gritsan, Andrei; Lae, Chung Khim; Tran, Nhan Viet; Everaerts, Pieter; Hahn, Kristan Allan; Harris, Philip; Nahn, Steve; Rudolph, Matthew; Sung, Kevin; Betchart, Burton; Demina, Regina; Gotra, Yury; Korjenevski, Sergey; Miner, Daniel Carl; Orbaker, Douglas; Christofek, Leonard; Hooper, Ryan; Landsberg, Greg; Nguyen, Duong; Narain, Meenakshi; Speer, Thomas; Tsang, Ka Vang

    2009-01-01

    In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber optics, power supplies, and electronics intended for the operation at the LHC. A local chiller was used to circulate the coolant for low temperature operation. In order to understand the efficiency and alignment of the strip tracker modules, a cosmic ray trigger was implemented. From March through July 4.5 million triggers were recorded. This period, referred to as the Sector Test, provided practical experience with the operation of the Tracker, especially safety, data acquisition, power, and cooling systems. This paper describes the performance of the strip system during the Sector Test, which consisted of five distinct periods defined by the coolant temperature. Significant emphasis is placed on comparisons between the data and results from Monte Carlo studies.

  5. Using Comic Strips in Language Classes

    Science.gov (United States)

    Csabay, Noémi

    2006-01-01

    The author believes that using comic strips in language-learning classes has three main benefits. First, comic strips motivate younger learners. Second, they provide a context and logically connected sentences to help language learning. Third, their visual information is helpful for comprehension. The author argues that comic strips can be used in…

  6. 49 CFR 571.208a - Optional test procedures for vehicles manufactured between January 27, 2004 and August 31, 2004.

    Science.gov (United States)

    2010-10-01

    ... with the vehicles brake or clutch pedal, rotate the test dummy's left foot about the leg. If there is... pedal in that position. S16.3.2.2.2 If the ball of the foot does not contact the pedal, change the angle... the vehicle's brake or clutch pedal, rotate the test dummy's left foot about the lower leg. If there...

  7. Method of stripping solid particles

    International Nuclear Information System (INIS)

    1980-01-01

    A method of stripping loaded solid particles is specified in which uniform batches of the loaded particles are passed successively upwardly through an elution column in the form of discrete plugs, the particles of which do not intermingle substantially with the particles of the vertically adjacent plug(s), and are contacted therein with eluant liquid flowed downwardly, strong eluate being withdrawn from the lower region of the column, the loaded particles being supplied as a slurry in a carrier liquid, and successive batches of loaded particles being isolated as measured batches and being separated from their carrier liquid before being contacted with strong eluate and slurried with the strong eluate into the lower region of the column. An example describes the stripping of ion exchange resin particles loaded with complex uranium ions. (author)

  8. Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors

    CERN Document Server

    Losel, Philipp Jonathan; The ATLAS collaboration

    2015-01-01

    Resisitve strip Micromegas detectors behave discharge tolerant. They have been tested extensively as smaller detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100\\,kHz/cm$^2$ and above. Tracking resolutions well below 100\\,$\\mu$m have been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3\\,m$^2$ in size. To investigate possible differences between small and large detectors, a 1\\,m$^2$ detector with 2048 resistive strips at a pitch of 450 $\\mu$m was studied in the LMU Cosmic Ray Facility (CRF) using two 4 $\\times$ 2.2 m$^2$ large Monitored Drift Tube (MDT) chambers for cosmic muon reference tracking. Segmentation of the resistive strip anode plane in 57.6\\,mm x 95\\,mm large areas has been realized by the readout of 128 strips with one APV25 chip each and by 11 95\\,mm broad trigger scintillators placed along the readout strips.\\\\ This allows for mapping of homogenity in pulse height and efficiency, deter...

  9. Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00389527; The ATLAS collaboration

    2016-01-01

    Resistive strip Micromegas detectors are discharge tolerant. They have been tested extensively as small detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100 kHz/cm$^2$ and above. Tracking resolution well below 100 $\\mu$m has been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3 m$^2$ in size. To investigate possible differences between small and large detectors, a 1 m$^2$ detector with 2048 resistive strips at a pitch of 450 $\\mu$m was studied in the LMU Cosmic Ray Measurement Facility (CRMF) using two 4 $\\times$ 2.2 m$^2$ large Monitored Drift Tube (MDT) chambers for cosmic muon reference tracking. A segmentation of the resistive strip anode plane in 57.6 mm x 93 mm large areas has been realized by the readout of 128 strips with one APV25 chip each and by eleven 93 mm broad trigger scintillators placed along the readout strips. This allows for mapping of homogeneity in pulse height and efficiency, d...

  10. A plane mirror experiment inspired by a comic strip

    Science.gov (United States)

    Lúcio Prados Ribeiro, Jair

    2016-01-01

    A comic strip about a plane mirror was used in a high school optics test, and it was perceived that a large portion of the students believed that the mirror should be larger than the object so the virtual image could be entirely visible. Inspired on the comic strip, an experimental demonstration with flat mirrors was developed, in order to readdress this topic learning. Students were encouraged to create their own investigation of the phenomenon with a simple instrumental apparatus and also suggest different experimental approaches.

  11. In-well vapor stripping drilling and characterization work plan

    International Nuclear Information System (INIS)

    Koegler, K.J.

    1994-01-01

    This work plan provides the information necessary for drilling, sampling, and hydrologic testing of wells to be completed in support of a demonstration of the in-well vapor stripping system. The in-well vapor stripping system is a remediation technology designed to preferentially extract volatile organic compounds (VOCs) from contaminated groundwater by converting them to a vapor phase. Air-lift pumping is used to lift and aerate groundwater within the well. The volatiles escaping the aerated water are drawn off by a slight vacuum and treated at the surface while the water is allowed to infiltrate the vadose zone back to the watertable

  12. Efficiency measurements for 3D silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich, E-mail: ulrich.parzefall@physik.uni-freiburg.d [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Dalla Betta, Gian-Franco [INFN Trento and Universita di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Boscardin, Maurizio [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Koehler, Michael; Kuehn, Susanne; Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris; Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Zoboli, Andrea [INFN Trento and Universita di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2010-11-01

    Silicon strip detectors are widely used as part of the inner tracking layers in particle physics experiments. For applications at the luminosity upgrade of the Large Hadron Collider (LHC), the sLHC, silicon detectors with extreme radiation hardness are required. The 3D detector design, where electrodes are processed from underneath the strips into the silicon bulk material, provides a way to enhance the radiation tolerance of standard planar silicon strip detectors. Detectors with several innovative 3D designs that constitute a simpler and more cost-effective processing than the 3D design initially proposed were connected to read-out electronics from LHC experiments and subsequently tested. Results on the amount of charge collected, the noise and the uniformity of charge collection are given.

  13. Global nuclear energy partnership fuels transient testing at the Sandia National Laboratories nuclear facilities : planning and facility infrastructure options

    International Nuclear Information System (INIS)

    Kelly, John E.; Wright, Steven Alan; Tikare, Veena; MacLean, Heather J.; Parma, Edward J.Jr; Peters, Curtis D.; Vernon, Milton E.; Pickard, Paul S.

    2007-01-01

    The Global Nuclear Energy Partnership fuels development program is currently developing metallic, oxide, and nitride fuel forms as candidate fuels for an Advanced Burner Reactor. The Advance Burner Reactor is being designed to fission actinides efficiently, thereby reducing the long-term storage requirements for spent fuel repositories. Small fuel samples are being fabricated and evaluated with different transuranic loadings and with extensive burnup using the Advanced Test Reactor. During the next several years, numerous fuel samples will be fabricated, evaluated, and tested, with the eventual goal of developing a transmuter fuel database that supports the down selection to the most suitable fuel type. To provide a comparative database of safety margins for the range of potential transmuter fuels, this report describes a plan to conduct a set of early transient tests in the Annular Core Research Reactor at Sandia National Laboratories. The Annular Core Research Reactor is uniquely qualified to perform these types of tests because of its wide range of operating capabilities and large dry central cavity which extents through the center of the core. The goal of the fuels testing program is to demonstrate that the design and fabrication processes are of sufficient quality that the fuel will not fail at its design limit--up to a specified burnup, power density, and operating temperature. Transient testing is required to determine the fuel pin failure thresholds and to demonstrate that adequate fuel failure margins exist during the postulated design basis accidents

  14. Global nuclear energy partnership fuels transient testing at the Sandia National Laboratories nuclear facilities : planning and facility infrastructure options.

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, John E.; Wright, Steven Alan; Tikare, Veena; MacLean, Heather J. (Idaho National Laboratory, Idaho Falls, ID); Parma, Edward J., Jr.; Peters, Curtis D.; Vernon, Milton E.; Pickard, Paul S.

    2007-10-01

    The Global Nuclear Energy Partnership fuels development program is currently developing metallic, oxide, and nitride fuel forms as candidate fuels for an Advanced Burner Reactor. The Advance Burner Reactor is being designed to fission actinides efficiently, thereby reducing the long-term storage requirements for spent fuel repositories. Small fuel samples are being fabricated and evaluated with different transuranic loadings and with extensive burnup using the Advanced Test Reactor. During the next several years, numerous fuel samples will be fabricated, evaluated, and tested, with the eventual goal of developing a transmuter fuel database that supports the down selection to the most suitable fuel type. To provide a comparative database of safety margins for the range of potential transmuter fuels, this report describes a plan to conduct a set of early transient tests in the Annular Core Research Reactor at Sandia National Laboratories. The Annular Core Research Reactor is uniquely qualified to perform these types of tests because of its wide range of operating capabilities and large dry central cavity which extents through the center of the core. The goal of the fuels testing program is to demonstrate that the design and fabrication processes are of sufficient quality that the fuel will not fail at its design limit--up to a specified burnup, power density, and operating temperature. Transient testing is required to determine the fuel pin failure thresholds and to demonstrate that adequate fuel failure margins exist during the postulated design basis accidents.

  15. New Concept of Cultivation Using Limited Strip-Tillage with Strip Shallow Irrigation

    Directory of Open Access Journals (Sweden)

    Yazid Ismi Intara

    2014-04-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE Dry land is one of land resources which potentially used for food crop cultivation, especially in the areas which have light to medium technical obstacles. The development of technology to improve soil quality in marginal lands to be productive lands is still widely open for agricultural development in Indonesia. Rooting medium quality can be improved by changing soil tillage method and observing the proper crop irrigation technology. It can be the solution for crop cultivation in clay loam soil. This study aimed to obtain water movement model in a minimally-tilled clay soil with strip shallow irrigation. The concept is limited soil-tillage with strip shallow irrigation method, water supply technique, and crop water requirement. Method used in this study includes developing water movement model (software development in a minimally-tilled clay soil with subsurface irrigation. In the final stages, research also conducted water movement analysis testing apparatus in the laboratory, field validation of the subsurface irrigation performance, and cultivation technique testing to chili pepper growth (Capsicum annuumL.. The development of water movement simulation on a limited strip-tillage with subsurface irrigation uses the concept to quantify the amount of water in the soil. The analysis of movement pattern was demonstrated on contour patterns. It showed that the wetting process can reach depth zone – 5 cm to the rooting zone. It was an important discovery on the development of minimum stripe tillage soil with subsurface irrigation. Specifically, it can be concluded that: the result of fitting by eyes to diffusivity graphic and water content obtained the required parameter values for soil physical properties. It was then simulated on horizontal water movement model on a minimum strip-tillage with strip shallow irrigation /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso

  16. The silicon strip detector at the Mark 2

    International Nuclear Information System (INIS)

    Jacobsen, R.; Golubev, V.; Lueth, V.; Barnett, B.; Dauncey, P.; Matthews, J.; Adolphsen, C.; Burchat, P.; Gratta, G.; King, M.; Labarga, L.; Litke, A.; Turala, M.; Zaccardelli, C.

    1990-04-01

    We have installed a Silicon Strip Vertex Detector in the Mark II detector at the Stanford Linear Collider. We report on the performance of the detector during a recent test run, including backgrounds, stability and charged particle tracking. 10 refs., 9 figs

  17. Collisional stripping of planetary crusts

    Science.gov (United States)

    Carter, Philip J.; Leinhardt, Zoë M.; Elliott, Tim; Stewart, Sarah T.; Walter, Michael J.

    2018-02-01

    Geochemical studies of planetary accretion and evolution have invoked various degrees of collisional erosion to explain differences in bulk composition between planets and chondrites. Here we undertake a full, dynamical evaluation of 'crustal stripping' during accretion and its key geochemical consequences. Crusts are expected to contain a significant fraction of planetary budgets of incompatible elements, which include the major heat producing nuclides. We present smoothed particle hydrodynamics simulations of collisions between differentiated rocky planetesimals and planetary embryos. We find that the crust is preferentially lost relative to the mantle during impacts, and we have developed a scaling law based on these simulations that approximates the mass of crust that remains in the largest remnant. Using this scaling law and a recent set of N-body simulations of terrestrial planet formation, we have estimated the maximum effect of crustal stripping on incompatible element abundances during the accretion of planetary embryos. We find that on average approximately one third of the initial crust is stripped from embryos as they accrete, which leads to a reduction of ∼20% in the budgets of the heat producing elements if the stripped crust does not reaccrete. Erosion of crusts can lead to non-chondritic ratios of incompatible elements, but the magnitude of this effect depends sensitively on the details of the crust-forming melting process on the planetesimals. The Lu/Hf system is fractionated for a wide range of crustal formation scenarios. Using eucrites (the products of planetesimal silicate melting, thought to represent the crust of Vesta) as a guide to the Lu/Hf of planetesimal crust partially lost during accretion, we predict the Earth could evolve to a superchondritic 176Hf/177Hf (3-5 parts per ten thousand) at present day. Such values are in keeping with compositional estimates of the bulk Earth. Stripping of planetary crusts during accretion can lead to

  18. Silicon strip detector qualification for the CMS experiment

    International Nuclear Information System (INIS)

    Kaussen, Gordon

    2008-01-01

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  19. Silicon strip detector qualification for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kaussen, Gordon

    2008-10-06

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  20. Energy exotic options

    International Nuclear Information System (INIS)

    Kaminski, V.; Gibner, S.; Pinnamaneni, K.

    1999-01-01

    This chapter with 88 references focuses on the use of exotic options to control exposure to energy prices. Exotic options are defined, and the conversion of a standard option into an exotic option and pricing models are examined. Pricing and hedging exotic options, path-dependent options, multi-commodity options, options on the minimum-or-maximum of two commodities, compound options, digital options, hybrid and complex structures, and natural gas daily options are described. Formulas for option pricing for vanilla, barrier, compound, options on minimum or maximum of two assets, and look back options are given in an appendix

  1. Cascade air stripping: Techno-economic evaluation of a new ground water treatment process

    International Nuclear Information System (INIS)

    Nirmalakhandan, N.; Peace, G.L.; Shanbhag, A.R.; Speece, R.E.

    1992-01-01

    A simple modification of the conventional air-stripping process introduced as cascade air stripping is proposed for efficient and economical removal of semivolatile and low volatility contaminants from ground water. The technical feasibility and economic viability of this process are evaluated using field test results and cost model simulations. The field tests enabled the process model to be verified at various water flow rates ranging from 150 gpm to 400 gpm. The field study also demonstrated the feasibility of the proposed system at a near full-scale level. Cost models were used to compare the proposed process to conventional air stripping and granular-activated carbon adsorption in removing a range of contaminants. This analysis showed that the treatment cost (cents/1,000 gal) of cascade air stripping is about 15% lower than conventional air stripping and about 40% lower than granular-activated carbon adsorption

  2. Prospects for the use of high-Tc superconductors in fusion magnets and options for their test in SULTAN

    International Nuclear Information System (INIS)

    Wesche, Rainer; Bruzzone, Pierluigi; March, Stephen; Marinucci, Claudio; Stepanov, Boris; Uglietti, Davide

    2013-01-01

    Highlights: ► RE-123 tapes j c ≥ 500 A/cm (77 K) would enable fusion magnets operating above 20 K. ► Quench studies indicate that the protection of RE-123 fusion magnets is a challenge. ► Possibilities to test 50 kA class HTS conductors in SULTAN have been identified. ► HTS bus bar of large thermal resistance needed to connect sample and NbTi flux pump. ► Tests in the 20–50 K range require additional changes in the SULTAN cryogenics. -- Abstract: In the last few years, the critical current densities of long commercially available REBa 2 Cu 3 O 7−x (RE-123, where RE represents Y or a rare earth element) coated conductors have reached values of 250 A/cm-width at 77 K and zero applied field. Even higher values of 600 A/cm-w (77 K, B = 0) have been demonstrated in shorter lengths. The attractive features of the use of these high-T c superconductors (HTS) are operation temperatures above 20 K and/or magnetic fields higher than those envisaged for the ITER TF coils. Possible operation conditions for HTS fusion magnets have been studied taking into consideration the possible further improvements of RE-123 coated conductors. Investigations of stability and quench behavior indicate that stability is not a problem, whereas quench detection and protection need attention. Because of the high currents necessary for fusion magnets, many tapes need to be assembled into a transposed conductor. The qualification of HTS conductors for fusion magnets would require their test at magnetic fields of 11 T and currents well above 10 kA. The possibilities to test straight HTS conductor samples in SULTAN have been considered. For a test at 4.5 K, only the development of a low resistance joint between the HTS conductor under test and the NbTi transformer of SULTAN would be necessary. Tests up to 20 K would require that the HTS sample is connected with the NbTi transformer by a conduction-cooled HTS bus bar of large thermal resistance similar to the HTS module of a current

  3. HIV Testing Practices and Interest in Self-Testing Options among Young, Black Men Who Have Sex with Men in North Carolina

    Science.gov (United States)

    HURT, Christopher B.; SONI, Karina; MILLER, William C.; HIGHTOW-WEIDMAN, Lisa B.

    2016-01-01

    Background Young, Black men who have sex with men (YBMSM) experience disproportionately high HIV incidence in the United States. Relative to other at-risk populations, less is known about their HIV testing behaviors and preferences regarding self-testing. Methods We used an online survey to investigate testing practices and interest in self-testing among HIV-uninfected, 18–30 year-old YBMSM in North Carolina. Results From July 2014 – March 2015, 212 completed the survey; median age was 24 years. Among 175 (83%) who had ever been tested, 160 (91%) reported testing in the prior year, 124 (71%) tested at least every 6 months, and 71 (40%) tested at least quarterly. About three-quarters (77%; n=164) were aware of HIV self-testing; 35 (17%) had ever purchased rapid (n=27) or dried blood spot-based (n=14) kits. Participants aware of kits had greater intention to test in the next 6 months; were more likely to have income for basic necessities and to ask sex partners about HIV status; and were less likely to have a main sex partner or to have had transactional sex. Among 142 participants at least somewhat likely to self-test in the future, convenience (35%), privacy (23%), and rapid result delivery (18%) were the principal motivators. Conclusions Eight of every ten YBMSM have ever been tested for HIV, but inter-test intervals remain unacceptably long for many. Awareness of and interest in self-testing is substantial, but few have used this method. Expanded use of self-tests could help increase the frequency of HIV testing in this epidemiologically important population. PMID:27513387

  4. Options theory

    International Nuclear Information System (INIS)

    Markland, J.T.

    1992-01-01

    Techniques used in conventional project appraisal are mathematically very simple in comparison to those used in reservoir modelling, and in the geosciences. Clearly it would be possible to value assets in mathematically more sophisticated ways if it were meaningful and worthwhile so to do. The DCf approach in common use has recognized limitations; the inability to select a meaningful discount rate being particularly significant. Financial Theory has advanced enormously over the last few years, along with computational techniques, and methods are beginning to appear which may change the way we do project evaluations in practice. The starting point for all of this was a paper by Black and Scholes, which asserts that almost all corporate liabilities can be viewed as options of varying degrees of complexity. Although the financial presentation may be unfamiliar to engineers and geoscientists, some of the concepts used will not be. This paper outlines, in plain English, the basis of option pricing theory for assessing the market value of a project. it also attempts to assess the future role of this type of approach in practical Petroleum Exploration and Engineering economics. Reference is made to relevant published Natural Resource literature

  5. PILOT TESTING: PRETREATMENT OPTIONS TO ALLOW RE-USE OF FRAC FLOWBACK AND PRODUCED BRINE FOR GAS SHALE RESOURCE DEVELOPMENT

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, David

    2012-12-31

    The goal of the A&M DOE NETL Project No. DE-FE0000847 was to develop a mobile, multifunctional water treatment capability designed specifically for “pre-treatment” of field waste brine. The project consisted of constructing s mobile “field laboratory” incorporating new technology for treating high salinity produced water and using the lab to conduct a side-by-side comparison between this new technology and that already existing in field operations. A series of four field trials were performed utilizing the mobile unit to demonstrate the effectiveness of different technology suitable for use with high salinity flow back brines and produced water. The design of the mobile unit was based on previous and current work at the Texas A&M Separation Sciences Pilot Plant. The several treatment techniques which have been found to be successful in both pilot plant and field tests had been tested to incorporate into a single multifunctional process train. Eight different components were evaluated during the trials, two types of oil and grease removal, one BTEX removal step, three micro-filters, and two different nanofilters. The performance of each technique was measured by its separation efficiency, power consumption, and ability to withstand fouling. The field trials were a success. Four different field brines were evaluated in the first trial in New York. Over 16,000 gallons of brine were processed. Using a power cost of $.10 per kWh, media pretreatment power use averaged $0.004 per barrel, solids removal $.04 per barrel and brine “softening” $.84 per barrel. Total power cost was approximately $1.00 per barrel of fluid treated. In Pennsylvania, brines collected from frac ponds were tested in two additional trials. Each of the brines was converted to an oil-free, solids-free brine with no biological activity. Brines were stable over time and would be good candidates for use as a make-up fluid in a subsequent fracturing fluid design. Reports on all of the field

  6. Paired preference data with a no-preference option – Statistical tests for comparison with placebo data

    DEFF Research Database (Denmark)

    Christensen, Rune Haubo Bojesen; Ennis, John M.; Ennis, Daniel M.

    2014-01-01

    /preference responses or ties in choice experiments. Food Quality and Preference, 23, 13–17) noted that this proportion can depend on the product category, have proposed that the expected proportion of preference responses within a given category be called an identicality norm, and have argued that knowledge...... of such norms is valuable for more complete interpretation of 2-Alternative Choice (2-AC) data. For instance, these norms can be used to indicate consumer segmentation even with non-replicated data. In this paper, we show that the statistical test suggested by Ennis and Ennis (2012a) behaves poorly and has too...... when ingredient changes are considered for cost-reduction or health initiative purposes....

  7. Depletive stripping chronopotentiometry : a major step forward in electrochemical stripping techniques for metal ion speciation analysis

    NARCIS (Netherlands)

    Town, R.M.; Leeuwen, van H.P.

    2004-01-01

    A comparative evaluation of the utility of the various modes of stripping chronopotentiometry (SCP) for trace metal speciation analysis is presented in the broad context of stripping voltammetric techniques. The remarkable fundamental advantages of depletive SCP at scanned deposition potential

  8. Potential profile in a conducting polymer strip

    DEFF Research Database (Denmark)

    Bay, Lasse; West, Keld; Vlachopoulos, Nikolaos

    2002-01-01

    Many conjugated polymers show an appreciable difference in volume between their oxidized and reduced forms. This property can be utilized in soft electrochemically driven actuators, "artificial muscles". Several geometries have been proposed for the conversion of the volume expansion into useful...... mechanical work. In a particularly simple geometry, the length change of polymer strips is exploited. The polymer strips are connected to the driving circuit at the end of the strip that is attached to the support of the device. The other end of the strip is connected to the load. The advantage of this set...

  9. Optimizing the Stripping Procedure for LHCb

    CERN Document Server

    Richardson, Rachel

    2017-01-01

    The LHCb experiment faces a major challenge from the large amounts of data received while the LHC is running. The ability to sort this information in a useful manner is important for working groups to perform physics analyses. Both hardware and software triggers are used to decrease the data rate and then the stripping process is used to sort the data into streams and further into stripping lines. This project studies the hundreds of stripping lines to look for overlaps between them in order to make the stripping process more efficient.

  10. Study on lifetime of C stripping foils

    International Nuclear Information System (INIS)

    Zhang Hongbin; Lu Ziwei; Zhao Yongtao; Li Zhankui; Xu Hushan; Xiao Guoqing; Wang Yuyu; Zhang Ling; Li Longcai; Fang Yan

    2007-01-01

    The carbon stripping foils can be prepared with the AC and DC arc discharge methods, or even sandwiched with AC-DC alternative layers. The lifetime of the carbon stripping foils of 19 μg/cm 2 prepared with different methods and/or structures was measured. The factors affecting the bombarding lifetime of the carbon stripping foils, especially the method of the foil preparation and the structure of the carbon stripping foils, were discussed. It is observed that the foils prepared with the DC arc discharge method have a longer bombarding lifetime than those prepared with the AC arc discharge method. (authors)

  11. Coplanar strips for Josephson voltage standard circuits

    International Nuclear Information System (INIS)

    Schubert, M.; May, T.; Wende, G.; Fritzsch, L.; Meyer, H.-G.

    2001-01-01

    We present a microwave circuit for Josephson voltage standards. Here, the Josephson junctions are integrated in a microwave transmission line designed as coplanar strips (CPS). The new layout offers the possibility of achieving a higher scale of integration and to considerably simplify the fabrication technology. The characteristic impedance of the CPS is about 50 Ω, and this should be of interest for programmable Josephson voltage standard circuits with SNS or SINIS junctions. To demonstrate the function of the microwave circuit design, conventional 10 V Josephson voltage standard circuits with 17000 Nb/AlO x /Nb junctions were prepared and tested. Stable Shapiro steps at the 10 V level were generated. Furthermore, arrays of 1400 SINIS junctions in this microwave layout exhibited first-order Shapiro steps. Copyright 2001 American Institute of Physics

  12. The Whipple Strip Sky Survey

    Science.gov (United States)

    Kertzman, M. P.

    As part of the normal operation of the Whipple 10m Gamma Ray telescope, ten minute drift scan “zenith” runs are made each night of observation for use as calibration. Most of the events recorded during a zenith run are due to the background of cosmic ray showers. However, it would be possible for a hitherto unknown source of gamma rays to drift through the field. This paper reports the results of a search for serendipitous high energy gamma ray sources in the Whipple 10m nightly calibration zenith data. From 2000-2004 nightly calibration runs were taken at an elevation of 89 º. A 2- D analysis of these drift scan runs produces a strip of width ~ 3.5º in declination and spanning the full range of right ascension. In the 2004-05 observing season the calibration runs were taken at elevations of 86° and 83°. Beginning in the 2005-06 season, the nightly calibration runs were taken at an elevation of 80º. Collectively, these drift scans cover a strip approximately 12.5º wide in declination, centered at declination 37.18º, and spanning the full range of RA. The analysis procedures developed for drift scan data, the sensitivity of the method, and the results will be presented.

  13. The new silicon strip detectors for the CMS tracker upgrade

    International Nuclear Information System (INIS)

    Dragicevic, M.

    2010-01-01

    The first introductory part of the thesis describes the concept of the CMS experiment. The tasks of the various detector systems and their technical implementations in CMS are explained. To facilitate the understanding of the basic principles of silicon strip sensors, the subsequent chapter discusses the fundamentals in semiconductor technology, with particular emphasis on silicon. The necessary process steps to manufacture strip sensors in a so-called planar process are described in detail. Furthermore, the effects of irradiation on silicon strip sensors are discussed. To conclude the introductory part of the thesis, the design of the silicon strip sensors of the CMS Tracker are described in detail. The choice of the substrate material and the complex geometry of the sensors are reviewed and the quality assurance procedures for the production of the sensors are presented. Furthermore the design of the detector modules are described. The main part of this thesis starts with a discussion on the demands on the tracker caused by the increase in luminosity which is proposed as an upgrade to the LHC accelerator (sLHC). This chapter motivates the work I have conducted and clarifies why the solutions proposed by myself are important contributions to the upgrade of the CMS tracker. The following chapters present the concepts that are necessary to operate the silicon strip sensors at sLHC luminosities and additional improvements to the construction and quality assurance of the sensors and the detector modules. The most important concepts and works presented in chapters 7 to 9 are: Development of a software framework to enable the flexible and quick design of test structures and sensors. Selecting a suitable sensor material which is sufficiently radiation hard. Design, implementation and production of a standard set of test structures to enable the quality assurance of such sensors and any future developments. Electrical characterisation of the test structures and analysis

  14. Utilization of Cell-Transfer Technique for Molecular Testing on Hematoxylin-Eosin-Stained Sections: A Viable Option for Small Biopsies That Lack Tumor Tissues in Paraffin Block.

    Science.gov (United States)

    Wu, Howard H; Jovonovich, Stephen M; Randolph, Melissa; Post, Kristin M; Sen, Joyashree D; Curless, Kendra; Cheng, Liang

    2016-12-01

    - In some instances the standard method of doing molecular testing from formalin-fixed, paraffin-embedded block is not possible because of limited tissue. Tumor cell-enriched cell-transfer technique has been proven useful for performing immunocytochemistry and molecular testing on cytologic smears. - To establish the cell-transfer technique as a viable option for isolating tumor cells from hematoxylin-eosin (H&E)-stained slides. - Molecular testing was performed by using the cell-transfer technique on 97 archived H&E-stained slides from a variety of different tumors. Results were compared to the conventional method of molecular testing. - Polymerase chain reaction-based molecular testing via the cell-transfer technique was successfully performed on 82 of 97 samples (85%). This included 39 of 47 cases for EGFR, 10 of 11 cases for BRAF, and 33 of 39 cases for KRAS mutations. Eighty-one of 82 cell-transfer technique samples (99%) showed agreement with previous standard method results, including 4 mutations and 35 wild-type alleles for EGFR, 4 mutations and 6 wild-type alleles for BRAF, and 11 mutations and 21 wild-type alleles for KRAS. There was only 1 discrepancy: a cell-transfer technique with a false-negative >KRAS result (wild type versus G12C). - Molecular testing performed on H&E-stained sections via cell-transfer technique is useful when tissue from cell blocks and small surgical biopsy samples is exhausted and the only available material for testing is on H&E-stained slides.

  15. Generalized thick strip modelling for vortex-induced vibration of long flexible cylinders

    International Nuclear Information System (INIS)

    Bao, Y.; Palacios, R.; Graham, M.; Sherwin, S.

    2016-01-01

    We propose a generalized strip modelling method that is computationally efficient for the VIV prediction of long flexible cylinders in three-dimensional incompressible flow. In order to overcome the shortcomings of conventional strip-theory-based 2D models, the fluid domain is divided into “thick” strips, which are sufficiently thick to locally resolve the small scale turbulence effects and three dimensionality of the flow around the cylinder. An attractive feature of the model is that we independently construct a three-dimensional scale resolving model for individual strips, which have local spanwise scale along the cylinder's axial direction and are only coupled through the structural model of the cylinder. Therefore, this approach is able to cover the full spectrum for fully resolved 3D modelling to 2D strip theory. The connection between these strips is achieved through the calculation of a tensioned beam equation, which is used to represent the dynamics of the flexible body. In the limit, however, a single “thick” strip would fill the full 3D domain. A parallel Fourier spectral/hp element method is employed to solve the 3D flow dynamics in the strip-domain, and then the VIV response prediction is achieved through the strip–structure interactions. Numerical tests on both laminar and turbulent flows as well as the comparison against the fully resolved DNS are presented to demonstrate the applicability of this approach.

  16. Generalized thick strip modelling for vortex-induced vibration of long flexible cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Y., E-mail: ybao@sjtu.edu.cn [Department of Civil Engineering, School of Naval Architecture, Ocean and Civil Engineering, Shanghai Jiaotong University, No. 800 Dongchuan Road, Shanghai (China); Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Palacios, R., E-mail: r.palacios@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Graham, M., E-mail: m.graham@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Sherwin, S., E-mail: s.sherwin@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom)

    2016-09-15

    We propose a generalized strip modelling method that is computationally efficient for the VIV prediction of long flexible cylinders in three-dimensional incompressible flow. In order to overcome the shortcomings of conventional strip-theory-based 2D models, the fluid domain is divided into “thick” strips, which are sufficiently thick to locally resolve the small scale turbulence effects and three dimensionality of the flow around the cylinder. An attractive feature of the model is that we independently construct a three-dimensional scale resolving model for individual strips, which have local spanwise scale along the cylinder's axial direction and are only coupled through the structural model of the cylinder. Therefore, this approach is able to cover the full spectrum for fully resolved 3D modelling to 2D strip theory. The connection between these strips is achieved through the calculation of a tensioned beam equation, which is used to represent the dynamics of the flexible body. In the limit, however, a single “thick” strip would fill the full 3D domain. A parallel Fourier spectral/hp element method is employed to solve the 3D flow dynamics in the strip-domain, and then the VIV response prediction is achieved through the strip–structure interactions. Numerical tests on both laminar and turbulent flows as well as the comparison against the fully resolved DNS are presented to demonstrate the applicability of this approach.

  17. 360-degrees profilometry using strip-light projection coupled to Fourier phase-demodulation.

    Science.gov (United States)

    Servin, Manuel; Padilla, Moises; Garnica, Guillermo

    2016-01-11

    360 degrees (360°) digitalization of three dimensional (3D) solids using a projected light-strip is a well-established technique in academic and commercial profilometers. These profilometers project a light-strip over the digitizing solid while the solid is rotated a full revolution or 360-degrees. Then, a computer program typically extracts the centroid of this light-strip, and by triangulation one obtains the shape of the solid. Here instead of using intensity-based light-strip centroid estimation, we propose to use Fourier phase-demodulation for 360° solid digitalization. The advantage of Fourier demodulation over strip-centroid estimation is that the accuracy of phase-demodulation linearly-increases with the fringe density, while in strip-light the centroid-estimation errors are independent. Here we proposed first to construct a carrier-frequency fringe-pattern by closely adding the individual light-strip images recorded while the solid is being rotated. Next, this high-density fringe-pattern is phase-demodulated using the standard Fourier technique. To test the feasibility of this Fourier demodulation approach, we have digitized two solids with increasing topographic complexity: a Rubik's cube and a plastic model of a human-skull. According to our results, phase demodulation based on the Fourier technique is less noisy than triangulation based on centroid light-strip estimation. Moreover, Fourier demodulation also provides the amplitude of the analytic signal which is a valuable information for the visualization of surface details.

  18. Colloidal gold probe based rapid immunochromatographic strip assay for cortisol

    International Nuclear Information System (INIS)

    Nara, Seema; Tripathi, Vinay; Singh, Harpal; Shrivastav, Tulsidas G.

    2010-01-01

    A rapid and semi-quantitative immunochromatographic strip (ICS) test for cortisol analysis in serum was developed. The test strip was based on a competitive assay format. Colloidal gold nanoparticles were synthesized and coupled with cortisol-3-carboxymethyloxime-adipic acid dihydrazide-bovine serum albumin (F-3-CMO-ADH-BSA) antigen to directly compete with cortisol in human serum samples. F-3-CMO-ADH-BSA-gold label and uncoupled colloidal gold nanoparticles were appropriately characterized using UV-vis spectroscopy, transmission electron microscopy and atomic force microscopy. Anticortisol antibody raised against F-3-CMO-BSA immunogen in New Zealand white rabbits was coated on the NC membrane as test line. Anti-BSA antibody was used as control line. The lower detection limit of the ICS test was 30 ng mL -1 with visual detection and was completed in 10 min. About 30 human serum samples were also analyzed by the developed strip test and their range of cortisol concentration was established. The developed ICS test is rapid, economic and user friendly.

  19. Colloidal gold probe based rapid immunochromatographic strip assay for cortisol

    Energy Technology Data Exchange (ETDEWEB)

    Nara, Seema, E-mail: seemanara@mnnit.ac.in [Department of Applied Mechanics (Biotechnology), Motilal Nehru National Institute of Technology, Allahabad 211004 (India); Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India); Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Tripathi, Vinay [Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India); Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Singh, Harpal [Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Shrivastav, Tulsidas G. [Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India)

    2010-12-03

    A rapid and semi-quantitative immunochromatographic strip (ICS) test for cortisol analysis in serum was developed. The test strip was based on a competitive assay format. Colloidal gold nanoparticles were synthesized and coupled with cortisol-3-carboxymethyloxime-adipic acid dihydrazide-bovine serum albumin (F-3-CMO-ADH-BSA) antigen to directly compete with cortisol in human serum samples. F-3-CMO-ADH-BSA-gold label and uncoupled colloidal gold nanoparticles were appropriately characterized using UV-vis spectroscopy, transmission electron microscopy and atomic force microscopy. Anticortisol antibody raised against F-3-CMO-BSA immunogen in New Zealand white rabbits was coated on the NC membrane as test line. Anti-BSA antibody was used as control line. The lower detection limit of the ICS test was 30 ng mL{sup -1} with visual detection and was completed in 10 min. About 30 human serum samples were also analyzed by the developed strip test and their range of cortisol concentration was established. The developed ICS test is rapid, economic and user friendly.

  20. Optimization of the process of steel strip perforation and nickel platting for the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strip

    Directory of Open Access Journals (Sweden)

    Petrović Aleksandra B.

    2009-01-01

    Full Text Available In the production of pocket type electrodes for Ni-Cd batteries perforation of proper steel strips and then nickel platting of perforated steel strips were made. In the nickel platting process, the organic solvent, trichloroethylene, has previously been used for cleaning. Due to the carcinogenic nature of trichloroethylene and the many operations previously required during cleaning, it was considered to do cleaning of perforated steel strips without use of the mentioned organic solvent. In the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strips, the tests of perforation of steel strips with use of oils of different viscosity were made. It was shown that there was no dysfunction during the work of the perforation plants, meaning there was no additional heating of the strips, deterring of the steel filings, nor excessive wearing of the perforation apparatus. The perforation percent was the same irrelevant of the viscosity of the used oil. Before being perforated using the oils with different viscosity, the nickel platting steel strips were cleaned in different degreasers (based on NaOH as well as on KOH. It was shown that efficient cleaning without the use of trichloroethylene is possible with the use of oil with smaller viscosity in the perforated steel strips process and the degreaser based on KOH in the cleaning process, before nickel platting. It also appeared that the alkali degreaser based on KOH was more efficient, bath corrections were made less often and the working period of the baths was longer, which all in summary means less quantity of chemicals needed for degreasing of perforated steel strips.

  1. Advancements of floating strip Micromegas detectors for medical imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Klitzner, Felix; Biebel, Otmar; Bortfeldt, Jonathan; Flierl, Bernhard [LS Schaile, LMU Muenchen (Germany); Magallanes, Lorena [LS Parodi, LMU Muenchen (Germany); Universitaetsklinikum Heidelberg (Germany); Parodi, Katia [LS Parodi, LMU Muenchen (Germany); Heidelberger Ionenstrahl Therapiezentrum (Germany); Voss, Bernd [Gesellschaft fuer Schwerionenforschung, Darmstadt (Germany)

    2016-07-01

    Floating strip Micromegas have proven to be high-rate capable tracking detectors with excellent spatial and temporal resolution for particle fluxes up to 7 MHz/cm{sup 2}. To further increase the high-rate capability a Ne:CF{sub 4} 86:14 vol.% gas mixture has been used as detector gas. We present results from measurements with a seven detector system consisting of six low material budget floating strip Micromegas, a GEM detector and a scintillator based particle range telescope. The gaseous and the scintillation detectors were read out with APV25 frontend boards, allowing for single strip readout with pulse height and timing information. A two-dimensional readout anode for floating strip Micromegas has been tested for the first time. The Micromegas detectors were operated with minimal additional drift field, which significantly improves the timing resolution and also the spatial resolution for inclined tracks. We discuss the detector performance in high-rate carbon and proton beams at the Heidelberg Ion Beam Therapy Center (HIT) and present radiographies of phantoms, acquired with the system.

  2. Development of a Calibration Strip for Immunochromatographic Assay Detection Systems.

    Science.gov (United States)

    Gao, Yue-Ming; Wei, Jian-Chong; Mak, Peng-Un; Vai, Mang-I; Du, Min; Pun, Sio-Hang

    2016-06-29

    With many benefits and applications, immunochromatographic (ICG) assay detection systems have been reported on a great deal. However, the existing research mainly focuses on increasing the dynamic detection range or application fields. Calibration of the detection system, which has a great influence on the detection accuracy, has not been addressed properly. In this context, this work develops a calibration strip for ICG assay photoelectric detection systems. An image of the test strip is captured by an image acquisition device, followed by performing a fuzzy c-means (FCM) clustering algorithm and maximin-distance algorithm for image segmentation. Additionally, experiments are conducted to find the best characteristic quantity. By analyzing the linear coefficient, an average value of hue (H) at 14 min is chosen as the characteristic quantity and the empirical formula between H and optical density (OD) value is established. Therefore, H, saturation (S), and value (V) are calculated by a number of selected OD values. Then, H, S, and V values are transferred to the RGB color space and a high-resolution printer is used to print the strip images on cellulose nitrate membranes. Finally, verification of the printed calibration strips is conducted by analyzing the linear correlation between OD and the spectral reflectance, which shows a good linear correlation (R² = 98.78%).

  3. Low material budget floating strip Micromegas for ion transmission radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, J., E-mail: jonathan.bortfeldt@cern.ch [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Magallanes, L. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); University Hospital Heidelberg, Im Neuenheimer Feld 672, D-69120 Heidelberg (Germany); Müller, R. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Parodi, K. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); Heidelberg Ion-Beam Therapy Center, Im Neuenheimer Feld 450, D-69120 Heidelberg (Germany); Schlüter, T. [LMU Munich, Excellence Cluster Universe, Boltzmannstr. 2, D-85748 Garching (Germany); Voss, B. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt (Germany); Zibell, A. [JMU Würzburg, Sanderring 2, D-97070 Würzburg (Germany)

    2017-02-11

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm{sup 2} with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X{sub 0}. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF{sub 4} gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  4. Mechanical behaviour of a creased thin strip

    Directory of Open Access Journals (Sweden)

    J. Liu

    2018-02-01

    Full Text Available In this study the mechanical behaviour of a creased thin strip under opposite-sense bending was investigated. It was found that a simple crease, which led to the increase of the second moment of area, could significantly alter the overall mechanical behaviour of a thin strip, for example the peak moment could be increased by 100 times. The crease was treated as a cylindrical segment of a small radius. Parametric studies demonstrated that the geometry of the strip could strongly influence its flexural behaviour. We showed that the uniform thickness and the radius of the creased segment had the greatest and the least influence on the mechanical behaviour, respectively. We further revealed that material properties could dramatically affect the overall mechanical behaviour of the creased strip by gradually changing the material from being linear elastic to elastic-perfect plastic. After the formation of the fold, the moment of the two ends of the strip differed considerably when the elasto-plastic materials were used, especially for materials with smaller tangent modulus in the plastic range. The deformation patterns of the thin strips from the finite element simulations were verified by physical models made of thin metal strips. The findings from this study provide useful information for designing origami structures for engineering applications using creased thin strips.

  5. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1978-01-01

    A bimetallic grid spacer is described comprising a grid structure of zircaloy formed by intersecting striplike members which define fuel element openings for receiving fuel elements and spring strips made of Inconel positioned within the grid structure for cooperating with the fuel elements to maintain them in their desired position. A plurality of these spring strips extend longitudinally between sides of the grid structure, being locked in position by the grid retaining strips. The fuel rods, which are disposed in the fuel openings formed in the grid structure, are positioned by means of the springs associated with the spring strips and a plurality of dimples which extend from the zircaloy grid structure into the openings. In one embodiment the strips are disposed in a plurality of arrays with those spring strip arrays situated in opposing diagonal quadrants of the grid structure extending in the same direction and adjacent spring strip arrays in each half of the spacer extending in relatively perpendicular directions. Other variations of the spring strip arrangements for a particular fuel design are disclosed herein

  6. CMS Silicon Strip Tracker Performance

    CERN Document Server

    Agram, Jean-Laurent

    2012-01-01

    The CMS Silicon Strip Tracker (SST), consisting of 9.6 million readout channels from 15148 modules and covering an area of 198 square meters, needs to be precisely calibrated in order to correctly reconstruct the events recorded. Calibration constants are derived from different workflows, from promptly reconstructed events with particles as well as from commissioning events gathered just before the acquisition of physics runs. The performance of the SST has been carefully studied since the beginning of data taking: the noise of the detector, data integrity, signal-over-noise ratio, hit reconstruction efficiency and resolution have been all investigated with time and for different conditions. In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

  7. The CMS silicon strip tracker

    International Nuclear Information System (INIS)

    Focardi, E.; Albergo, S.; Angarano, M.; Azzi, P.; Babucci, E.; Bacchetta, N.; Bader, A.; Bagliesi, G.; Bartalini, P.; Basti, A.; Biggeri, U.; Bilei, G.M.; Bisello, D.; Boemi, D.; Bosi, F.; Borrello, L.; Bozzi, C.; Braibant, S.; Breuker, H.; Bruzzi, M.; Candelori, A.; Caner, A.; Castaldi, R.; Castro, A.; Catacchini, E.; Checcucci, B.; Ciampolini, P.; Civinini, C.; Creanza, D.; D'Alessandro, R.; Da Rold, M.; Demaria, N.; De Palma, M.; Dell'Orso, R.; Marina, R. Della; Dutta, S.; Eklund, C.; Elliott-Peisert, A.; Feld, L.; Fiore, L.; French, M.; Freudenreich, K.; Fuertjes, A.; Giassi, A.; Giraldo, A.; Glessing, B.; Gu, W.H.; Hall, G.; Hammerstrom, R.; Hebbeker, T.; Hrubec, J.; Huhtinen, M.; Kaminsky, A.; Karimaki, V.; Koenig, St.; Krammer, M.; Lariccia, P.; Lenzi, M.; Loreti, M.; Luebelsmeyer, K.; Lustermann, W.; Maettig, P.; Maggi, G.; Mannelli, M.; Mantovani, G.; Marchioro, A.; Mariotti, C.; Martignon, G.; Evoy, B. Mc; Meschini, M.; Messineo, A.; My, S.; Paccagnella, A.; Palla, F.; Pandoulas, D.; Parrini, G.; Passeri, D.; Pieri, M.; Piperov, S.; Potenza, R.; Raffaelli, F.; Raso, G.; Raymond, M.; Santocchia, A.; Schmitt, B.; Selvaggi, G.; Servoli, L.; Sguazzoni, G.; Siedling, R.; Silvestris, L.; Skog, K.; Starodumov, A.; Stavitski, I.; Stefanini, G.; Tempesta, P.; Tonelli, G.; Tricomi, A.; Tuuva, T.; Vannini, C.; Verdini, P.G.; Viertel, G.; Xie, Z.; Wang, Y.; Watts, S.; Wittmer, B.

    1999-01-01

    The Silicon Strip Tracker (SST) is the intermediate part of the CMS Central Tracker System. SST is based on microstrip silicon devices and in combination with pixel detectors and the Microstrip Gas Chambers aims at performing pattern recognition, track reconstruction and momentum measurements for all tracks with p T ≥2 GeV/c originating from high luminosity interactions at √s=14 TeV at LHC. We aim at exploiting the advantages and the physics potential of the precise tracking performance provided by the microstrip silicon detectors on a large scale apparatus and in a much more difficult environment than ever. In this paper we describe the actual SST layout and the readout system. (author)

  8. Deep percolation in greenhouse-cultivated celery using the technique of subsurface film strips placement

    Directory of Open Access Journals (Sweden)

    Zhida Du

    2014-05-01

    Full Text Available To reduce the deep percolation during greenhouse vegetable cultivation, the technique of subsurface film strips placement was tested. Four treatments with two kinds of cross-sections (flat and U-shaped and two different spacings (10 cm and 40 cm of subsurface film strips were arranged in a greenhouse before planting celery. At the same time, a non-film treatment was arranged for comparison. Soil water content was measured and irrigation time was adjusted according to the soil water content. Evapotranspiration of celery during growth was calculated by the method of energy balance and the deep percolation was calculated by the equation of water balance. Deep percolation was reduced in all experimental treatments. Greater reduction in deep percolation was observed when using U-shaped cross-section strips compared with that using the flat cross-section strips. In addition, greater reduction in deep percolation was observed when the spacing between the film strips was smaller. The results of this test showed that the technique of subsurface film strips placement can reduce deep percolation and conserve irrigation water for greenhouse vegetables cultivation. However, the optimal layout variables for the use of the technique of subsurface film strips placement need further experimental and numerical analysis.

  9. Evaluation of the performance of irradiated silicon strip sensors for the forward detector of the ATLAS Inner Tracker Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Mori, R., E-mail: riccardo.mori@physik.uni-freiburg.de [Physikalisches Institut, Universität Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Allport, P.P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J.P.; Wilson, J.A. [School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom); Kierstead, J.; Kuczewski, P.; Lynn, D. [Brookhaven National Laboratory, Physics Department and Instrumentation Division, Upton, NY 11973-5000 (United States); Arratia-Munoz, M.I.; Hommels, L.B.A. [Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Ullan, M.; Fleta, C.; Fernandez-Tejero, J. [Centro Nacional de Microelectronica (IMB-CNM, CSIC), Campus UAB-Bellaterra, 08193 Barcelona (Spain); Bloch, I.; Gregor, I.M.; Lohwasser, K. [DESY, Notkestrasse 85, 22607 Hambrug (Germany); and others

    2016-09-21

    The upgrade to the High-Luminosity LHC foreseen in about ten years represents a great challenge for the ATLAS inner tracker and the silicon strip sensors in the forward region. Several strip sensor designs were developed by the ATLAS collaboration and fabricated by Hamamatsu in order to maintain enough performance in terms of charge collection efficiency and its uniformity throughout the active region. Of particular attention, in the case of a stereo-strip sensor, is the area near the sensor edge where shorter strips were ganged to the complete ones. In this work the electrical and charge collection test results on irradiated miniature sensors with forward geometry are presented. Results from charge collection efficiency measurements show that at the maximum expected fluence, the collected charge is roughly halved with respect to the one obtained prior to irradiation. Laser measurements show a good signal uniformity over the sensor. Ganged strips have a similar efficiency as standard strips.

  10. Options to Expand HIV Viral Load Testing in South Africa: Evaluation of the GeneXpert® HIV-1 Viral Load Assay.

    Directory of Open Access Journals (Sweden)

    Natasha Gous

    Full Text Available Expansion of HIV viral load (VL testing services are required to meet increased targets for monitoring patients on antiretroviral treatment. South Africa currently tests >4million VLs per annum in 16 highly centralised, automated high-throughput laboratories. The Xpert HIV-1 VL assay (Cepheid was evaluated against in-country predicates, the Roche Cobas Taqmanv2 and Abbott HIV-1RT, to investigate options for expanding VL testing using GeneXpert's random access, polyvalent capabilities and already established footprint in South Africa with the Xpert MTB/RIF assay (207 sites. Additionally, the performance of Xpert HIV-1VL on alternative, off-label specimen types, Dried Blood Spots (DBS and whole blood, was investigated.Precision, accuracy (agreement and clinical misclassification (1000cp/ml of Xpert HIV-1VL plasma was compared to Taqmanv2 (n = 155 and Abbott HIV-1 RT (n = 145. Misclassification of Xpert HIV-1VL was further tested on DBS (n = 145 and whole blood (n = 147.Xpert HIV-1VL demonstrated 100% concordance with predicate platforms on a standardised frozen, plasma panel (n = 42 and low overall percentage similarity CV of 1.5% and 0.9% compared to Taqmanv2 and Abbott HIV-1 RT, respectively. On paired plasma clinical specimens, Xpert HIV-1VL had low bias (SD 0.32-0.37logcp/ml and 3% misclassification at the 1000cp/ml threshold compared to Taqmanv2 (fresh and Abbott HIV-1 RT (frozen, respectively. Xpert HIV-1VL on whole blood and DBS increased misclassification (upward by up to 14% with increased invalid rate. All specimen testing was easy to perform and compatible with concurrent Xpert MTB/RIF Tuberculosis testing on the same instrument.The Xpert HIV-1VL on plasma can be used interchangeably with existing predicate platforms in South Africa. Whole blood and DBS testing requires further investigation, but polyvalency of the GeneXpert offers a solution to extending VL testing services.

  11. Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

    CERN Document Server

    Francis, K.; Schlereth, J.; Smith, J.; Xia, L.; Baldolemar, E.; Li, J.; Park, S.T.; Sosebee, M.; White, A.P.; Yu, J.; Eigen, G.; Mikami, Y.; Watson, N.K.; Thomson, M.A.; Ward, D.R.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.; Apostolakis, J.; Dotti, A.; Folger, G.; Ivantchenko, V.; Ribon, A.; Uzhinskiy, V.; Carloganu, C.; Gay, P.; Manen, S.; Royer, L.; Tytgat, M.; Zaganidis, N.; Blazey, G.C.; Dyshkant, A.; Lima, J.G.R.; Zutshi, V.; Hostachy, J. -Y.; Morin, L.; Cornett, U.; David, D.; Ebrahimi, A.; Falley, G.; Gadow, K.; Goettlicher, P.; Guenter, C.; Hartbrich, O.; Hermberg, B.; Karstensen, S.; Krivan, F.; Krueger, K.; Lutz, B.; Morozov, S.; Morgunov, V.; Neubueser, C.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Terwort, M.; Garutti, E.; Laurien, S.; Lu, S.; Marchesini, I.; Matysek, M.; Ramilli, M.; Briggl, K.; Eckert, P.; Harion, T.; Schultz-Coulon, H. -Ch.; Shen, W.; Stamen, R.; Bilki, B.; Norbeck, E.; Northacker, D.; Onel, Y.; Wilson, G.W.; Kawagoe, K.; Sudo, Y.; Yoshioka, T.; Dauncey, P.D.; Wing, M.; Salvatore, F.; Cortina Gil, E.; Mannai, S.; Baulieu, G.; Calabria, P.; Caponetto, L.; Combaret, C.; Della Negra, R.; Grenier, G.; Han, R.; Ianigro, J-C.; Kieffer, R.; Laktineh, I.; Lumb, N.; Mathez, H.; Mirabito, L.; Petrukhin, A.; Steen, A.; Tromeur, W.; Vander donckt, M.; Zoccarato, Y.; Calvo Alamillo, E.; Fouz, M.-C.; Puerta-Pelayo, J.; Corriveau, F.; Bobchenko, B.; Chadeeva, M.; Danilov, M.; Epifantsev, A.; Markin, O.; Mizuk, R.; Novikov, E.; Popov, V.; Rusinov, V.; Tarkovsky, E.; Besson, D.; Buzhan, P.; Ilyin, A.; Kantserov, V.; Kaplin, V.; Karakash, A.; Popova, E.; Tikhomirov, V.; Kiesling, C.; Seidel, K.; Simon, F.; Soldner, C.; Weuste, L.; Amjad, M.S.; Bonis, J.; Callier, S.; Conforti di Lorenzo, S.; Cornebise, P.; Doublet, Ph.; Dulucq, F.; Fleury, J.; Frisson, T.; van der Kolk, N.; Li, H.; Martin-Chassard, G.; Richard, F.; de la Taille, Ch.; Poeschl, R.; Raux, L.; Rouene, J.; Seguin-Moreau, N.; Anduze, M.; Balagura, V.; Boudry, V.; Brient, J-C.; Cornat, R.; Frotin, M.; Gastaldi, F.; Guliyev, E.; Haddad, Y.; Magniette, F.; Musat, G.; Ruan, M.; Tran, T.H.; Videau, H.; Bulanek, B.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Ghazlane, H.; Kotera, K.; Ono, H.; Takeshita, T.; Uozumi, S.; Jeans, D.; Chang, S.; Khan, A.; Kim, D.H.; Kong, D.J.; Oh, Y.D.; Goetze, M.; Sauer, J.; Weber, S.; Zeitnitz, C.

    2014-11-01

    A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.

  12. First thin AC-coupled silicon strip sensors on 8-inch wafers

    Energy Technology Data Exchange (ETDEWEB)

    Bergauer, T., E-mail: thomas.bergauer@oeaw.ac.at [Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, 1050 Wien (Vienna) (Austria); Dragicevic, M.; König, A. [Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, 1050 Wien (Vienna) (Austria); Hacker, J.; Bartl, U. [Infineon Technologies Austria AG, Siemensstrasse 2, 9500 Villach (Austria)

    2016-09-11

    The Institute of High Energy Physics (HEPHY) in Vienna and the semiconductor manufacturer Infineon Technologies Austria AG developed a production process for planar AC-coupled silicon strip sensors manufactured on 200 μm thick 8-inch p-type wafers. In late 2015, the first wafers were delivered featuring the world's largest AC-coupled silicon strip sensors. Detailed electrical measurements were carried out at HEPHY, where single strip and global parameters were measured. Mechanical studies were conducted and the long-term behavior was investigated using a climate chamber. Furthermore, the electrical properties of various test structures were investigated to validate the quality of the manufacturing process.

  13. New developments in double sided silicon strip detectors

    International Nuclear Information System (INIS)

    Becker, H.; Boulos, T.; Cattaneo, P.; Dietl, H.; Hauff, D.; Holl, P.; Lange, E.; Lutz, G.; Moser, H.G.; Schwarz, A.S.; Settles, R.; Struder, L.; Kemmer, J.; Buttler, W.

    1990-01-01

    A new type of double sided silicon strip detector has been built and tested using highly density VLSI readout electronics connected to both sides. Capacitive coupling of the strips to the readout electronics has been achieved by integrating the capacitors into the detector design, which was made possible by introducing a new detector biasing concept. Schemes to simplify the technology of the fabrication of the detectors are discussed. The static performance properties of the devices as well as implications of the use of VLSI electronics in their readout are described. Prototype detectors of the described design equipped with high density readout electronics have been installed in the ALEPH detector at LEP. Test results on the performance are given

  14. Infrared LED Array For Silicon Strip Detector Qualification

    CERN Document Server

    Dirkes, Guido; Hartmann, Frank; Heier, Stefan; Schwerdtfeger, Wolfgang; Waldschmitt, M; Weiler, K W; Weseler, Siegfried

    2003-01-01

    The enormous amount of silicon strip detector modules for the CMS tracker requires a test-sytem to allow qualification of each individual detector module and its front-end electronics within minutes. The objective is to test the detector with a physical signal. Signals are generated in the detector by illumination with lightpulses emitted by a LED at 950~nm and with a rise time of 10~ns. In order to avoid a detector moving, an array of 64 LEDs is used, overlaping the complete detector width. The total length of an array is 15~cm. The spot size of an individual LED is controlled by apertures to illuminate about 25 strips. Furthermore it is possible to simulate the high leakage current of irradiated sensors by constant illumination of the sensor. This provides an effective mean to identfy pinholes on a sensor.

  15. Prototype Strip Barrel Modules for the ATLAS ITk Strip Detector

    CERN Document Server

    Sawyer, Craig; The ATLAS collaboration

    2017-01-01

    The module design for the Phase II Upgrade of the new ATLAS Inner Tracker (ITk) detector at the LHC employs integrated low mass assembly using single-sided flexible circuits with readout ASICs and a powering circuit incorporating control and monitoring of HV, LV and temperature on the module. Both readout and powering circuits are glued directly onto the silicon sensor surface resulting in a fully integrated, extremely low radiation length module which simultaneously reduces the material requirements of the local support structure by allowing a reduced width stave structure to be employed. Such a module concept has now been fully demonstrated using so-called ABC130 and HCC130 ASICs fabricated in 130nm CMOS technology to readout ATLAS12 n+-in-p silicon strip sensors. Low voltage powering for these demonstrator modules has been realised by utilising a DCDC powerboard based around the CERN FEAST ASIC. This powerboard incorporates an HV multiplexing switch based on a Panasonic GaN transistor. Control and monitori...

  16. Transfusion and blood donation in comic strips.

    Science.gov (United States)

    Lefrère, Jean-Jacques; Danic, Bruno

    2013-07-01

    The representation of blood transfusion and donation of blood in the comic strip has never been studied. The comic strip, which is a relatively recent art, emerged in the 19th century before becoming a mass medium during the 20th century. We have sought, by calling on collectors and using the resources of Internet, comic strips devoted, wholly or in part, to the themes of transfusion and blood donation. We present some of them here in chronologic order, indicating the title, country of origin, year of publication, and names of authors. The theme of the superhero using transfusion to transmit his virtues or his powers is repeated throughout the 20th century in North American comic strips. More recently, comic strips have been conceived from the outset with a promotional aim. They perpetuate positive images and are directed toward a young readership, wielding humor to reduce the fear of venipuncture. Few comic strips denounce the abuse of the commercialization of products derived from the human body. The image of transfusion and blood donation given by the comic strips is not to be underestimated because their readership is primarily children, some of whom will become blood donors. Furthermore, if some readers are transfused during their lives, the impact of a memory more or less conscious of these childhood readings may resurface, both in hopes and in fears. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Resistive-strips micromegas detectors with two-dimensional readout

    Science.gov (United States)

    Byszewski, M.; Wotschack, J.

    2012-02-01

    Micromegas detectors show very good performance for charged particle tracking in high rate environments as for example at the LHC. It is shown that two coordinates can be extracted from a single gas gap in these detectors. Several micromegas chambers with spark protection by resistive strips and two-dimensional readout have been tested in the context of the R&D work for the ATLAS Muon System upgrade.

  18. Selecting chemical and ecotoxicological test batteries for risk assessment of trace element-contaminated soils (phyto)managed by gentle remediation options (GRO).

    Science.gov (United States)

    Kumpiene, Jurate; Bert, Valérie; Dimitriou, Ioannis; Eriksson, Jan; Friesl-Hanl, Wolfgang; Galazka, Rafal; Herzig, Rolf; Janssen, Jolien; Kidd, Petra; Mench, Michel; Müller, Ingo; Neu, Silke; Oustriere, Nadège; Puschenreiter, Markus; Renella, Giancarlo; Roumier, Pierre-Hervé; Siebielec, Grzegorz; Vangronsveld, Jaco; Manier, Nicolas

    2014-10-15

    During the past decades a number of field trials with gentle remediation options (GRO) have been established on trace element (TE) contaminated sites throughout Europe. Each research group selects different methods to assess the remediation success making it difficult to compare efficacy between various sites and treatments. This study aimed at selecting a minimum risk assessment battery combining chemical and ecotoxicological assays for assessing and comparing the effectiveness of GRO implemented in seven European case studies. Two test batteries were pre-selected; a chemical one for quantifying TE exposure in untreated soils and GRO-managed soils and a biological one for characterizing soil functionality and ecotoxicity. Soil samples from field studies representing one of the main GROs (phytoextraction in Belgium, Sweden, Germany and Switzerland, aided phytoextraction in France, and aided phytostabilization or in situ stabilization/phytoexclusion in Poland, France and Austria) were collected and assessed using the selected test batteries. The best correlations were obtained between NH4NO3-extractable, followed by NaNO3-extractable TE and the ecotoxicological responses. Biometrical parameters and biomarkers of dwarf beans were the most responsive indicators for the soil treatments and changes in soil TE exposures. Plant growth was inhibited at the higher extractable TE concentrations, while plant stress enzyme activities increased with the higher TE extractability. Based on these results, a minimum risk assessment battery to compare/biomonitor the sites phytomanaged by GROs might consist of the NH4NO3 extraction and the bean Plantox test including the stress enzyme activities. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Nitrogen removal from digested slurries using a simplified ammonia stripping technique.

    Science.gov (United States)

    Provolo, Giorgio; Perazzolo, Francesca; Mattachini, Gabriele; Finzi, Alberto; Naldi, Ezio; Riva, Elisabetta

    2017-11-01

    This study assessed a novel technique for removing nitrogen from digested organic waste based on a slow release of ammonia that was promoted by continuous mixing of the digestate and delivering a continuous air stream across the surface of the liquid. Three 10-day experiments were conducted using two 50-L reactors. In the first two, nitrogen removal efficiencies were evaluated from identical digestates maintained at different temperatures (30°C and 40°C). At the start of the first experiment, the digestates were adjusted to pH 9 using sodium hydroxide, while in the second experiment pH was not adjusted. The highest ammonia removal efficiency (87%) was obtained at 40°C with pH adjustment. However at 40°C without pH adjustment, removal efficiencies of 69% for ammonia and 47% for total nitrogen were obtained. In the third experiment two different digestates were tested at 50°C without pH adjustment. Although the initial chemical characteristics of the digestates were different in this experiment, the ammonia removal efficiencies were very similar (approximately 85%). Despite ammonia removal, the pH increased in all experiments, most likely due to carbon dioxide stripping that was promoted by temperature and mixing. The technique proved to be suitable for removing nitrogen following anaerobic digestion of livestock manure because effective removal was obtained at natural pH (≈8) and 40°C, common operating conditions at typical biogas plants that process manure. Furthermore, the electrical energy requirement to operate the process is limited (estimated to be 3.8kWhm -3 digestate). Further improvements may increase the efficiency and reduce the processing time of this treatment technique. Even without these advances slow-rate air stripping of ammonia is a viable option for reducing the environmental impact associated with animal manure management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Stripping voltammetry in environmental and food analysis.

    Science.gov (United States)

    Brainina, K Z; Malakhova, N A; Stojko, N Y

    2000-10-01

    The review covers over 230 papers published mostly in the last 5 years. The goal of the review is to attract the attention of researchers and users to stripping voltammetry in particular, its application in environmental monitoring and analysis of foodstuffs. The sensors employed are impregnated graphite, carbon paste, thick film carbon/graphite and thin film metallic electrodes modified in-situ or beforehand. Hanging mercury drop electrodes and mercury coated glassy carbon electrodes are also mentioned. Strip and long-lived sensors for portable instruments and flow through systems are discussed as devices for future development and application of stripping voltammetry.

  1. Hardness of approximation for strip packing

    DEFF Research Database (Denmark)

    Adamaszek, Anna Maria; Kociumaka, Tomasz; Pilipczuk, Marcin

    2017-01-01

    Strip packing is a classical packing problem, where the goal is to pack a set of rectangular objects into a strip of a given width, while minimizing the total height of the packing. The problem has multiple applications, for example, in scheduling and stock-cutting, and has been studied extensively......)-approximation by two independent research groups [FSTTCS 2016,WALCOM 2017]. This raises a questionwhether strip packing with polynomially bounded input data admits a quasi-polynomial time approximation scheme, as is the case for related twodimensional packing problems like maximum independent set of rectangles or two...

  2. A GEM readout with radial zigzag strips and linear charge-sharing response

    Science.gov (United States)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; Purschke, Martin L.; Woody, Craig

    2018-04-01

    We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Angular resolutions of 60-84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

  3. Fatigue of graphite/epoxy buffer strip panels with center cracks

    Science.gov (United States)

    Bigelow, C. A.

    1985-01-01

    The effects of fatigue loading on the behavior of graphite/epoxy panels with either S-Glass or Kevlar-49 buffer strips is studied. Buffer strip panels are fatigued and tested in tension to measure their residual strength with crack-like damage. Panels are made with 45/0/-45/90 sub 2s layup with either S-Glass or Kevlar-49 buffer strip material. The buffer strips are parallel to the loading direction and made by replacing narrow strips of the 0-degree graphite plies with strips of either 0-degree S-Glass/epoxy or Kevlar-49/epoxy on a one-for-one basis. The panels are subjected to a fatigue loading spectrum MINITWIST, the shortened version of the standardized load program for the wing lower surface of a transport aircraft. Two levels of maximum strain are used in the spectrum with three durations of the fatigue spectrum. One group of panels is preloaded prior to the application of the fatigue cycling. The preload consists of statistically loading the spectrum in tension until the crack-tip damage zone reaches the ajacent buffer strips. After fatigue loading, all specimens are statistically loaded in tension to failure to determine their residual strengths.

  4. Developmental assessment of RELAP5/MOD3.1 with separate-effect and integral test experiments: model changes and options

    International Nuclear Information System (INIS)

    Analytis, G.T.

    1996-04-01

    A summary of modifications and options introduced in RELAP5/MOD3.1 (R5M3.1) is presented and it is shown that the predicting capabilities of the modified version of the code are greatly improved, while the general philosophy we followed in arriving at these modifications is also outlined. These changes which are the same ones we implemented in the past in the version 7j of the code, include 2 different heat transfer packages (one of them activated during reflooding), modification of the low mass-flux Groeneveld CHF look-up table and of the dispersed flow interfacial area (and shear) as well as of the criterion for transition into and out from this regime, almost complete elimination of the under-relaxation schemes of the interfacial closure coefficients etc. The modified R5M3.1 code is assessed against a number of separate-effect and integral test experiments and in contrast to the frozen version, is shown to result in physically sound predictions which are much closer to the measurements, while almost all the predicted variables are free of unphysical spurious oscillations. The modifications introduced solve a number of problems associated with the frozen version of the code and result in a version which can be confidently used both for SB-LOCA and LB-LOCA analyses. (author) 7 figs., 20 refs

  5. Corrosion and Mechanical Properties of HANA-6 Strip

    International Nuclear Information System (INIS)

    Lee, Myung Ho; Kim, Jun Hwan; Park, Sang Yoon; Choi, Byoung Kwon; Jeong, Yong Hwan; Kim, Yoon Ho; Chung, Jin Gon

    2007-01-01

    The Zircaloy-4, one of zirconium alloys, has been used as a nuclear fuel and structural material because it has a satisfactory mechanical strength and corrosion resistance. As in many plants it was attempted to increase their discharge burn-up and power level, the development of new zirconium alloys for a high burn-up fuel material has been required. In response to these needs, in 1997 KAERI started the development of some Zr-based new alloys, called HANA alloys, for high burn-up fuel cladding material and has tested the out-of-pile and in-pile performance of these HANA claddings after manufacturing the claddings with HANA alloys. The sample specimens of the HANA cladding tubes showed a good performance for both corrosion resistance and creep properties at an irradiation test up to 12GWD/MtU in Halden test reactor as well as at various out of- pile tests. It is also scheduled to start the verification test of the in-pile performance of the HANA claddings in a commercial reactor by the end of 2007. KAERI and KNFC are also trying to extend the applicability of these alloys to the spacer grid for PWR nuclear fuel. As one of these attempts, KAERI has tested the properties of HANA-6 strips of 241.3 mm in width, and both 0.457 and 0.667 mm in thickness manufactured with a larger scale in width than a laboratory scale. The same test is scheduled to carry out for HANA-4 strips with a time lag. This paper summarized the results of the corrosion test, tensile test and bending test for the HANA- 6 strips up to now

  6. The GLAST silicon-strip tracking system

    International Nuclear Information System (INIS)

    Johnson, Robert P.

    2000-01-01

    The GLAST instrument concept is a gamma-ray pair conversion telescope that uses silicon microstrip detector technology to track the electron-positron pairs resulting from gamma-ray conversions in thin lead foils. A cesium iodide calorimeter following the tracker is used to measure the gamma-ray energy. Silicon strip technology is mature and robust, with an excellent heritage in space science and particle physics. It has many characteristics important for optimal performance of a pair conversion telescope, including high efficiency in thin detector planes, low noise, and excellent resolution and two-track separation. The large size of GLAST and high channel count in the tracker puts demands on the readout technology to operate at very low power, yet with sufficiently low noise occupancy to allow self triggering. A prototype system employing custom-designed ASIC's has been built and tested that meets the design goal of approximately 200 W per channel power consumption with a noise occupancy of less than one hit per trigger per 10,000 channels. Detailed design of the full-scale tracker is well advanced, with non-flight prototypes built for all components, and a complete 50,000 channel engineering demonstration tower module is currently under construction and will be tested in particle beams in late 1999. The flight-instrument conceptual design is for a 4x4 array of tower modules with an aperture of 2.9 m2 and an effective area of greater than 8000 cm2

  7. The GLAST Silicon-Strip Tracking System

    International Nuclear Information System (INIS)

    Johnson, R

    2004-01-01

    The GLAST instrument concept is a gamma-ray pair conversion telescope that uses silicon microstrip detector technology to track the electron-positron pairs resulting from gamma ray conversions in thin lead foils. A cesium iodide calorimeter following the tracker is used to measure the gamma-ray energy. Silicon strip technology is mature and robust, with an excellent heritage in space science and particle physics. It has many characteristics important for optimal performance of a pair conversion telescope, including high efficiency in thin detector planes, low noise, and excellent resolution and two-track separation. The large size of GLAST and high channel count in the tracker puts demands on the readout technology to operate at very low power, yet with sufficiently low noise occupancy to allow self triggering. A prototype system employing custom-designed ASIC's has been built and tested that meets the design goal of approximately 200 (micro)W per channel power consumption with a noise occupancy of less than one hit per trigger per 10,000 channels. Detailed design of the full-scale tracker is well advanced, with non-flight prototypes built for all components, and a complete 50,000 channel engineering demonstration tower module is currently under construction and will be tested in particle beams in late 1999. The flight-instrument conceptual design is for a 4 x 4 array of tower modules with an aperture of 2.9 m 2 and an effective area of greater than 8000 cm 2

  8. Spray rolling aluminum alloy strip

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, Kevin M.; Delplanque, J.-P.; Johnson, S.B.; Lavernia, E.J.; Zhou, Y.; Lin, Y

    2004-10-10

    Spray rolling combines spray forming with twin-roll casting to process metal flat products. It consists of atomizing molten metal with a high velocity inert gas, cooling the resultant droplets in flight and directing the spray between mill rolls. In-flight convection heat transfer from atomized droplets teams with conductive cooling at the rolls to rapidly remove the alloy's latent heat. Hot deformation of the semi-solid material in the rolls results in fully consolidated, rapidly solidified product. While similar in some ways to twin-roll casting, spray rolling has the advantage of being able to process alloys with broad freezing ranges at high production rates. This paper describes the process and summarizes microstructure and tensile properties of spray-rolled 2124 and 7050 aluminum alloy strips. A Lagrangian/Eulerian poly-dispersed spray flight and deposition model is described that provides some insight into the development of the spray rolling process. This spray model follows droplets during flight toward the rolls, through impact and spreading, and includes oxide film formation and breakup when relevant.

  9. The Panda Strip Asic: Pasta

    Science.gov (United States)

    Lai, A.

    2018-01-01

    PASTA is the 64 channel front-end chip, designed in a 110 nm CMOS technology to read out the strip sensors of the Micro Vertex Detector (MVD) of the PANDA experiment. This chip provides high resolution timestamp and deposited charge information by means of the time-over-threshold technique. Its working principle is based on a predecessor, the TOFPET ASIC, that was designed for medical applications. A general restructuring of the architecture was needed, in order to meet the specific requirements imposed by the physics programme of PANDA, especially in terms of radiation tolerance, spatial constraints, and readout in absence of a first level hardware trigger. The first revision of PASTA is currently under evaluation at the Forschungszentrum Jülich, where a data acquisition system dedicated to the MVD prototypes has been developed. This paper describes the main aspect of the chip design, gives an overview of the data acquisition system used for the verification, and shows the first results regarding the performance of PASTA.

  10. Studies of adhesives and metal contacts on silicon strip sensors for the ATLAS Inner Tracker

    OpenAIRE

    Poley, Anne-Luise

    2018-01-01

    This thesis presents studies investigating the use of adhesives on the active area of silicon strip sensors for the construction of silicon strip detector modules for the ATLAS Phase-II Upgrade. 60 ATLAS07 miniature sensors were tested using three UV cure glues in comparison with the current baseline glue (a non-conductive epoxy).The impact of irradiation on the chemical composition of all adhesives under investigation was studied using three standard methods for chemical analysis: quadrupole...

  11. Comparative limnology of strip-mine lakes

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, J D

    1964-01-01

    Lakes were classified according to chemical properties. The concentration of the ferric iron oxides was responsible for a reddish-black turbidity which, in turn, played a major role in the thermal stratification of red strip-mine lakes. Owing to the lack of measurable turbidity and as a result of selective absorption of visible solar radiation, other strip-mine lakes appeared blue in color. The annual heat budget and the summer heat budget are essentially equivalent under saline conditions. Regardless of the physical and chemical conditions of the strip-mine lakes, heat income was a function of the circulating water mass. The progressive oxidation and precipitation of the iron oxides is the key to the classification of strip-mine lakes.

  12. Buffer Strips for Riparian Zone Management

    National Research Council Canada - National Science Library

    1991-01-01

    This study provides a review of technical literature concerning the width of riparian buffer strips needed to protect water quality and maintain other important values provided by riparian ecosystem...

  13. A new semicustom integrated bipolar amplifier for silicon strip detectors

    International Nuclear Information System (INIS)

    Zimmerman, T.

    1989-01-01

    The QPA02 is a four channel DC coupled two stage transimpedance amplifier designed at Fermilab on a semicustom linear array (Quickchip 2S) manufactured by Tektronix. The chip was developed as a silicon strip amplifier but may have other applications as well. Each channel consists of a preamplifier and a second stage amplifier/sharper with differential output which can directly drive a transmission line (90 to 140 ohms). External bypass capacitors are the only discrete components required. QPA02 has been tested and demonstrated to be an effective silicon strip amplifier. Other applications may exist which can use this amplifier or a modified version of this amplifier. For example, another design is now in progress for a wire chamber amplifier, QPA03, to be reported later. Only a relatively small effort was required to modify the design and layout for this application. 11 figs

  14. Deuteron stripping reactions using dirac phenomenology

    Science.gov (United States)

    Hawk, E. A.; McNeil, J. A.

    2001-04-01

    In this work deuteron stripping reactions are studied using the distorted wave born approximation employing dirac phenomenological potentials. In 1982 Shepard and Rost performed zero-range dirac phenomenological stripping calculations and found a dramatic reduction in the predicted cross sections when compared with similar nonrelativistic calculations. We extend the earlier work by including full finite range effects as well as the deuteron's internal D-state. Results will be compared with traditional nonrelativistic approaches and experimental data at low energy.

  15. Flexible strip supercapacitors for future energy storage

    OpenAIRE

    Zhang, R-R; Xu, Y-M; Harrison, D; Fyson, J; Qiu, F-L; Southee, D

    2015-01-01

    Flexible strip supercapacitors are developed and their electrochemical properties are characterized. Activated carbon is used as the electrode material and it is found to have a good porous structure which provides a large surface area for energy storage. Furthermore, this activated carbon performs well. The manufacturing processes for the supercapacitors are described in detail and the preparation process has good reproducibility. The strip supercapacitors are combined in series and parallel...

  16. The charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Boehringer, T.; Hubbeling, L.; Weilhammer, P.; Kemmer, J.; Koetz, U.; Riebesell, M.; Belau, E.; Klanner, R.; Lutz, G.; Neugebauer, E.; Seebrunner, H.J.; Wylie, A.

    1983-02-01

    The charge collection in silicon detectors has been studied, by measuring the response to high-energy particles of a 20μm pitch strip detector as a function of applied voltage and magnetic field. The results are well described by a simple model. The model is used to predict the spatial resolution of silicon strip detectors and to propose a detector with optimized spatial resolution. (orig.)

  17. Treatment Options for Retinoblastoma

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other places in the body. Treatment Option Overview Key Points There are different types of ...

  18. Bounds for Asian basket options

    Science.gov (United States)

    Deelstra, Griselda; Diallo, Ibrahima; Vanmaele, Michèle

    2008-09-01

    In this paper we propose pricing bounds for European-style discrete arithmetic Asian basket options in a Black and Scholes framework. We start from methods used for basket options and Asian options. First, we use the general approach for deriving upper and lower bounds for stop-loss premia of sums of non-independent random variables as in Kaas et al. [Upper and lower bounds for sums of random variables, Insurance Math. Econom. 27 (2000) 151-168] or Dhaene et al. [The concept of comonotonicity in actuarial science and finance: theory, Insurance Math. Econom. 31(1) (2002) 3-33]. We generalize the methods in Deelstra et al. [Pricing of arithmetic basket options by conditioning, Insurance Math. Econom. 34 (2004) 55-57] and Vanmaele et al. [Bounds for the price of discrete sampled arithmetic Asian options, J. Comput. Appl. Math. 185(1) (2006) 51-90]. Afterwards we show how to derive an analytical closed-form expression for a lower bound in the non-comonotonic case. Finally, we derive upper bounds for Asian basket options by applying techniques as in Thompson [Fast narrow bounds on the value of Asian options, Working Paper, University of Cambridge, 1999] and Lord [Partially exact and bounded approximations for arithmetic Asian options, J. Comput. Finance 10 (2) (2006) 1-52]. Numerical results are included and on the basis of our numerical tests, we explain which method we recommend depending on moneyness and time-to-maturity.

  19. The Strip Silicon Photo-Multiplier: An innovation for enhanced time and position measurement

    Energy Technology Data Exchange (ETDEWEB)

    Doroud, K., E-mail: Katayoun.Doroud@cern.ch [CERN, Geneva (Switzerland); Williams, M.C.S. [CERN, Geneva (Switzerland); INFN, Bologna (Italy); Yamamoto, K. [Solid State Division, Hamamatsu Photonics K.K., Hamamatsu (Japan)

    2017-05-01

    There is considerable R&D concerning precise time measurement from a variety of detectors, and in particular for the Silicon PhotoMultiplier (SiPM). In this paper we discuss a new geometry for the SiPM in the form of a strip. A strip can be read out at both end, with each end coupled to an individual TDC (time to digital converter). The time difference is related to the position of the firing SPAD along the length of the strip, while the average of the two times gives the time of the hit. Results from the testing of the first prototype Strip SiPMs are presented in this paper.

  20. The Analysis of a Wideband Strip-Helical Antenna with 1.1 Turns

    Directory of Open Access Journals (Sweden)

    Xihui Tang

    2016-01-01

    Full Text Available A wideband strip-helical antenna with 1.1 turns is analyzed numerically and experimentally. By replacing the traditional wire helix with wide metallic strip, the forward traveling current on the strip helix with about one turn smoothly decays to the minimum value at the open end of the helix. Therefore, the strip helix can excite a wideband circular polarization (CP wave with 50-ohm impedance matching. The proposed antenna is printed on a hollow-cylinder with a substrate relative permittivity of εr=2.2 and a thickness of h=0.5 mm. A 50 Ω coaxial cable is directly connected to excite the strip-helical antenna without any additional impedance matching section. The ground plane is placed below the antenna in order to provide a directional radiation pattern. To demonstrate this method, a prototype of 1.1-turn strip-helical antenna is tested. The test shows that the proposed antenna can reach an overlapped bandwidth of 46% with height of 0.52λ0, where λ0 is the wavelength in free space at the center operation frequency.

  1. Performance of a large-area GEM detector read out with wide radial zigzag strips

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Aiwu, E-mail: azhang@fit.edu; Bhopatkar, Vallary; Hansen, Eric; Hohlmann, Marcus; Khanal, Shreeya; Phipps, Michael; Starling, Elizabeth; Twigger, Jessie; Walton, Kimberly

    2016-03-01

    A 1-meter-long trapezoidal Triple-GEM detector with wide readout strips was tested in hadron beams at the Fermilab Test Beam Facility in October 2013. The readout strips have a special zigzag geometry and run radially with an azimuthal pitch of 1.37 mrad to measure the azimuthal ϕ-coordinate of incident particles. The zigzag geometry of the readout reduces the required number of electronic channels by a factor of three compared to conventional straight readout strips while preserving good angular resolution. The average crosstalk between zigzag strips is measured to be an acceptable 5.5%. The detection efficiency of the detector is (98.4±0.2)%. When the non-linearity of the zigzag-strip response is corrected with track information, the angular resolution is measured to be (193±3) μrad, which corresponds to 14% of the angular strip pitch. Multiple Coulomb scattering effects are fully taken into account in the data analysis with the help of a stand-alone Geant4 simulation that estimates interpolated track errors.

  2. A Portable Colloidal Gold Strip Sensor for Clenbuterol and Ractopamine Using Image Processing Technology

    Directory of Open Access Journals (Sweden)

    Yi Guo

    2013-01-01

    Full Text Available A portable colloidal golden strip sensor for detecting clenbuterol and ractopamine has been developed using image processing technology, as well as a novel strip reader has achieved innovatively with this imaging sensor. Colloidal gold strips for clenbuterol and ractopamine is used as first sensor with given biomedical immunication reaction. After three minutes the target sample dropped on, the color showing in the T line is relative to the content of objects as clenbuterol, this reader can finish many functions like automatic acquit ion of colored strip image, quantatively analysis of the color lines including the control line and test line, and data storage and transfer to computer. The system is integrated image collection, pattern recognition and real-time colloidal gold quantitative measurement. In experiment, clenbuterol and ractopamine standard substance with concentration from 0 ppb to 10 ppb is prepared and tested, the result reveals that standard solutions of clenbuterol and ractopamine have a good secondary fitting character with color degree (R2 is up to 0.99 and 0.98. Besides, through standard sample addition to the object negative substance, good recovery results are obtained up to 98 %. Above all, an optical sensor for colloidal strip measure is capable of determining the content of clenbuterol and ractopamine, it is likely to apply to quantatively identifying of similar reaction of colloidal golden strips.

  3. Field oxide radiation damage measurements in silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Laakso, M [Particle Detector Group, Fermilab, Batavia, IL (United States) Research Inst. for High Energy Physics (SEFT), Helsinki (Finland); Singh, P; Shepard, P F [Dept. of Physics and Astronomy, Univ. Pittsburgh, PA (United States)

    1993-04-01

    Surface radiation damage in planar processed silicon detectors is caused by radiation generated holes being trapped in the silicon dioxide layers on the detector wafer. We have studied charge trapping in thick (field) oxide layers on detector wafers by irradiating FOXFET biased strip detectors and MOS test capacitors. Special emphasis was put on studying how a negative bias voltage across the oxide during irradiation affects hole trapping. In addition to FOXFET biased detectors, negatively biased field oxide layers may exist on the n-side of double-sided strip detectors with field plate based n-strip separation. The results indicate that charge trapping occurred both close to the Si-SiO[sub 2] interface and in the bulk of the oxide. The charge trapped in the bulk was found to modify the electric field in the oxide in a way that leads to saturation in the amount of charge trapped in the bulk when the flatband/threshold voltage shift equals the voltage applied over the oxide during irradiation. After irradiation only charge trapped close to the interface is annealed by electrons tunneling to the oxide from the n-type bulk. (orig.).

  4. The ATLAS tracker strip detector for HL-LHC

    CERN Document Server

    Cormier, Kyle James Read; The ATLAS collaboration

    2016-01-01

    As part of the ATLAS upgrades for the High Luminsotiy LHC (HL-LHC) the current ATLAS Inner Detector (ID) will be replaced by a new Inner Tracker (ITk). The ITk will consist of two main components: semi-conductor pixels at the innermost radii, and silicon strips covering larger radii out as far as the ATLAS solenoid magnet including the volume currently occupied by the ATLAS Transition Radiation Tracker (TRT). The primary challenges faced by the ITk are the higher planned read out rate of ATLAS, the high density of charged particles in HL-LHC conditions for which tracks need to be resolved, and the corresponding high radiation doses that the detector and electronics will receive. The ITk strips community is currently working on designing and testing all aspects of the sensors, readout, mechanics, cooling and integration to meet these goals and a Technical Design Report is being prepared. This talk is an overview of the strip detector component of the ITk, highlighting the current status and the road ahead.

  5. The ATLAS tracker strip detector for HL-LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00512833; The ATLAS collaboration

    2017-01-01

    As part of the ATLAS upgrades for the High Luminsotiy LHC (HL-LHC) the current ATLAS Inner Detector (ID) will be replaced by a new Inner Tracker (ITk). The ITk will consist of two main components: semi-conductor pixels at the innermost radii, and silicon strips covering larger radii out as far as the ATLAS solenoid magnet including the volume currently occupied by the ATLAS Transition Radiation Tracker (TRT). The primary challenges faced by the ITk are the higher planned read out rate of ATLAS, the high density of charged particles in HL-LHC conditions for which tracks need to be resolved, and the corresponding high radiation doses that the detector and electronics will receive. The ITk strips community is currently working on designing and testing all aspects of the sensors, readout, mechanics, cooling and integration to meet these goals and a Technical Design Report is being prepared. This talk is an overview of the strip detector component of the ITk, highlighting the current status and the road ahead.

  6. Australian Asian Options

    OpenAIRE

    Manuel Moreno; Javier F. Navas

    2003-01-01

    We study European options on the ratio of the stock price to its average and viceversa. Some of these options are traded in the Australian Stock Exchange since 1992, thus we call them Australian Asian options. For geometric averages, we obtain closed-form expressions for option prices. For arithmetic means, we use different approximations that produce very similar results.

  7. Options with Extreme Strikes

    Directory of Open Access Journals (Sweden)

    Lingjiong Zhu

    2015-07-01

    Full Text Available In this short paper, we study the asymptotics for the price of call options for very large strikes and put options for very small strikes. The stock price is assumed to follow the Black–Scholes models. We analyze European, Asian, American, Parisian and perpetual options and conclude that the tail asymptotics for these option types fall into four scenarios.

  8. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    Science.gov (United States)

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  9. Results of Ageing Tests on the Forward MSGC 'BANANA' Prototype

    CERN Document Server

    Boimska, B; Capéans-Garrido, M; Claes, S; Hoch, Michael; Million, Gilbert; Ropelewski, Leszek; Sharma, Abhishek; Shekhtman, L I; Van Doninck, Walter; Van Lancker, Luc

    1996-01-01

    The forward tracker of the CMS experiment at CERN will consist of a large number of MicroStrip Gas Chambers ( MSGCs), expected to operate for several years in the high luminosity environment of LHC with an accumulated dose rate of ~ 10 mC/yr per cm of strip. They are planned to be arranged around the interaction point in modular wheels which contain several MSGCs. The 'open'option of a forward CMS 'banana' module includes the electronics inside the gas volume. Long term tests of one such prototype containing two plates, one with gold and the other with chromium strips on diamond-like coated D263 glass with representative electronics and surface mount components inside the gas volume have been performed; the satisfactory results are reported here. A first test has been made with a gas flow rate of 60 cc/min in the prototype ( corresponding to 5 gas renewals per hour) and has shown no gain drop up to 85 mC/cm of accumulated charge per strip. A second test has been performed with a gas flow rate of 6 cc/min corr...

  10. Experimental Investigations on the Pull-Out Behavior of Tire Strips Reinforced Sands.

    Science.gov (United States)

    Li, Li-Hua; Chen, Yan-Jun; Ferreira, Pedro Miguel Vaz; Liu, Yong; Xiao, Heng-Lin

    2017-06-27

    Waste tires have excellent mechanical performance and have been used as reinforcing material in geotechnical engineering; however, their interface properties are poorly understood. To further our knowledge, this paper examines the pull-out characteristics of waste tire strips in a compacted sand, together with uniaxial and biaxial geogrids also tested under the same conditions. The analysis of the results shows that the interlocking effect and pull-out resistance between the tire strip and the sand is very strong and significantly higher than that of the geogrids. In the early stages of the pull-out test, the resistance is mainly provided by the front portion of the embedded tire strips, as the pull-out test continues, more and more of the areas towards the end of the tire strips are mobilized, showing a progressive failure mechanism. The deformations are proportional to the frictional resistance between the tire-sand interface, and increase as the normal stresses increase. Tire strips of different wear intensities were tested and presented different pull-out resistances; however, the pull-out resistance mobilization patterns were generally similar. The pull-out resistance values obtained show that rubber reinforcement can provide much higher pull-out forces than the geogrid reinforcements tested here, showing that waste tires are an excellent alternative as a reinforcing system, regardless of the environmental advantages.

  11. Superconducting nano-strip particle detectors

    International Nuclear Information System (INIS)

    Cristiano, R; Ejrnaes, M; Casaburi, A; Zen, N; Ohkubo, M

    2015-01-01

    We review progress in the development and applications of superconducting nano-strip particle detectors. Particle detectors based on superconducting nano-strips stem from the parent devices developed for single photon detection (SSPD) and share with them ultra-fast response times (sub-nanosecond) and the ability to operate at a relatively high temperature (2–5 K) compared with other cryogenic detectors. SSPDs have been used in the detection of electrons, neutral and charged ions, and biological macromolecules; nevertheless, the development of superconducting nano-strip particle detectors has mainly been driven by their use in time-of-flight mass spectrometers (TOF-MSs) where the goal of 100% efficiency at large mass values can be achieved. Special emphasis will be given to this case, reporting on the great progress which has been achieved and which permits us to overcome the limitations of existing mass spectrometers represented by low detection efficiency at large masses and charge/mass ambiguity. Furthermore, such progress could represent a breakthrough in the field. In this review article we will introduce the device concept and detection principle, stressing the peculiarities of the nano-strip particle detector as well as its similarities with photon detectors. The development of parallel strip configuration is introduced and extensively discussed, since it has contributed to the significant progress of TOF-MS applications. (paper)

  12. Factors affecting hydrocarbon removal by air stripping

    International Nuclear Information System (INIS)

    McFarland, W.E.

    1992-01-01

    This paper includes an overview of the theory of air stripping design considerations and the factors affecting stripper performance. Effects of temperature, contaminant characteristics, stripping tower geometry and air/water ratios on removal performance are discussed. The discussion includes treatment of groundwater contaminated with petroleum hydrocarbons and chlorinated solvents such as TCE and PCE. Control of VOC emissions from air strippers has become a major concern in recent years, due to more stringent restrictions on air quality in many areas. This paper includes an overview of available technology to control air emissions (including activated carbon adsorption, catalytic oxidation and steam stripping) and the effects of air emission control on overall efficiency of the treatment process. The paper includes an overview of the relative performance of various packing materials for air strippers and explains the relative advantages and disadvantages of comparative packing materials. Field conditions affecting selection of packing materials are also discussed. Practical guidelines for the design of air stripping systems are presented, as well as actual case studies of full-scale air stripping projects

  13. Properties isotropy of magnesium alloy strip workpieces

    Directory of Open Access Journals (Sweden)

    Р. Кавалла

    2016-12-01

    Full Text Available The paper discusses the issue of obtaining high quality cast workpieces of magnesium alloys produced by strip roll-casting. Producing strips of magnesium alloys by combining the processes of casting and rolling when liquid melt is fed continuously to fast rolls is quite promising and economic. In the process of sheet stamping considerable losses of metal occur on festoons formed due to anisotropy of properties of foil workpiece, as defined by the macro- and microstructure and modes of rolling and annealing. The principal causes of anisotropic mechanical properties of metal strips produced by the combined casting and rolling technique are the character of distribution of intermetallic compounds in the strip, orientation of phases of metal defects and the residual tensions. One of the tasks in increasing the output of fit products during stamping operations consists in minimizing the amount of defects. To lower the level of anisotropy in mechanical properties various ways of treating the melt during casting are suggested. Designing the technology of producing strips of magnesium alloys opens a possibility of using them in automobile industry to manufacture light-weight body elements instead of those made of steel.

  14. Evaluation of Nobuto filter paper strips for the detection of avian influenza virus antibody in waterfowl

    Science.gov (United States)

    Dusek, Robert J.; Hall, Jeffrey S.; Nashold, Sean W.; Teslaa, Joshua L.; Ip, Hon S.

    2011-01-01

    The utility of using Nobuto paper strips for the detection of avian influenza antibodies was examined in mallards (Anas platyrhynchos) experimentally infected with low pathogenic avian influenza viruses. Blood was collected 2 wk after infection and was preserved either as serum or whole blood absorbed onto Nobuto strips. Analysis of samples using a commercially available blocking enzyme-linked immunosorbent assay revealed comparable results (???96% sensitivity for all methods) between sera stored at -30 C and the Nobuto strip preservation method even when the Nobuto strips were stored up to 3 mo at room temperature (RT). Significant differences were detected in the ratio of sample absorbance to negative control absorbance for Nobuto strips stored at RT compared with sera stored at -30 C, although these differences did not affect the ability of the test to reliably detect positive and negative samples. Nobuto strips are a convenient and sensitive alternative to the collection of serum samples when maintaining appropriate storage temperatures is difficult. ?? 2011 American Association of Avian Pathologists.

  15. stripping of uranium from DEHPA/TOPO solvent by ammonium carbonate solutions

    International Nuclear Information System (INIS)

    Khorfan, S.; Shino, O.; Wahood, A.; Dahdouh, A.

    2002-01-01

    Uranium is recovered from phosphoric acid by the DEHPA/TOPO process. In this process uranium is stripped from the loaded DEHPA/TOPO solvent in the second cycle by an ammonium carbonate solution. This paper studied stripping of uranium from 0.3 Mol DEHPA/0.075 Mol TOPO in kerosene by different ammonium carbonate solutions. The ammonium carbonate solutions tested were either made locally from ammonia and carbon dioxide gases or commercial and laboratory grades available on the market. A comparison was made between these carbonate solutions in terms of purity, stripping efficiency and phase separation. Both stripping and phase separation were carried out under different conditions of phase ratio and concentrations. The results obtained showed that ammonium carbonate prepared from direct synthesis of ammonia and carbon dioxide gases had a high purity and gave the same stripping yield as the laboratory grade. The phase separation was also slightly improved using a pure synthesized ammonium carbonate solution. the phase separation was found to be best at concentration of 0.5 Mol/L ammonium carbonate solution and at a phase A/O of 1/1 and a temperature of 50 degree centigrade. It was possible to obtain >99% yield by operating 2 stripping stages counter currently under these conditions. (authors)

  16. On the Formation of Ultra-Difuse Galaxies as Tidally-Stripped Systems

    Science.gov (United States)

    Carleton, Timothy; Cooper, Michael; Kaplinghat, Manoj; Errani, Raphael; Penarrubia, Jorge

    2018-01-01

    The recent identification of a large population of so-called 'Ultra-Diffuse' Galaxies (UDGs), with stellar masses ~108 M⊙, but half light radii over 1.5 kpc, has challenged our understanding of galaxy evolution. Motivated by the environmental dependence of UDG properties and abundance, I present a model for the formation of UDGs through tidal-stripping of dwarf galaxies in cored dark matter halos. To test this scenario, I utilize results from simulations of tidal stripping, which demonstrate that changes in the stellar profile of a tidally stripped galaxy can be written as a function of the amount of tidal stripping experienced by the halo (tidal tracks). These tracks, however, are different for cored and cuspy halos. Additional simulations show how the halo responds to tidal interactions given the halo orbit within a cluster.In particular, dwarf elliptical galaxies, born in 1010-10.5 M⊙ halos, expand significantly as a result of tidal stripping and produce UDGs. Applying these models to the population of halos in the Bolshoi simulation, I am able to follow the effects of tidal stripping on the dwarf galaxy population in clusters. Using tidal tracks for cuspy halos does not reproduce the observed properties of UDGs. However, using the tidal tracks for cored halos, I reproduce the distribution of sizes, stellar masses, and abundance of UDGs in clusters remarkably well.

  17. Analysis of 'Coma strip' galaxy redshift catalog

    International Nuclear Information System (INIS)

    Klypin, A.A.; Karachentsev, I.D.; Lebedev, V.S.

    1990-01-01

    We present results of the analysis of a galaxy redshift catalog made at the 6-m telescope by Karachentsev and Kopylov (1990. Mon. Not. R. astr. Soc., 243, 390). The catalog covers a long narrow strip on the sky (10 arcmin by 63 0 ) and lists 283 galaxies up to limiting blue magnitude m B = 17.6. The strip goes through the core of Coma cluster and this is called the 'Coma strip' catalog. The catalog is almost two times deeper than the CfA redshift survey and creates the possibility of studying the galaxy distribution on scales of 100-250 Mpc. Due to the small number of galaxies in the catalog, we were able to estimate only very general and stable parameters of the distribution. (author)

  18. Evaluating the Whitening and Microstructural Effects of a Novel Whitening Strip on Porcelain and Composite Dental Materials.

    Science.gov (United States)

    Takesh, Thair; Sargsyan, Anik; Lee, Matthew; Anbarani, Afarin; Ho, Jessica; Wilder-Smith, Petra

    2017-08-01

    The aim of this project was to evaluate the effects of 2 different whitening strips on color, microstructure and roughness of tea stained porcelain and composite surfaces. 54 porcelain and 72 composite chips served as samples for timed application of over-the-counter (OTC) test or control dental whitening strips. Chips were divided randomly into three groups of 18 porcelain and 24 composite chips each. Of these groups, 1 porcelain and 1 composite set served as controls. The remaining 2 groups were randomized to treatment with either Oral Essentials ® Whitening Strips or Crest ® 3D White Whitestrips™. Sample surface structure was examined by light microscopy, profilometry and Scanning Electron Microscopy (SEM). Additionally, a reflectance spectrophotometer was used to assess color changes in the porcelain and composite samples over 24 hours of whitening. Data points were analyzed at each time point using ANOVA. In the light microscopy and SEM images, no discrete physical defects were observed in any of the samples at any time points. However, high-resolution SEM images showed an appearance of increased surface roughness in all composite samples. Using profilometry, significantly increased post-whitening roughness was documented in the composite samples exposed to the control bleaching strips. Composite samples underwent a significant and equivalent shift in color following exposure to Crest ® 3D White Whitestrips™ and Oral Essentials ® Whitening Strips. A novel commercial tooth whitening strip demonstrated a comparable beaching effect to a widely used OTC whitening strip. Neither whitening strip caused physical defects in the sample surfaces. However, the control strip caused roughening of the composite samples whereas the test strip did not.

  19. Stage- vs. Channel-strip Metaphor

    DEFF Research Database (Denmark)

    Gelineck, Steven; Korsgaard, Dannie Michael; Büchert, Morten

    2015-01-01

    This study compares the stage metaphor and the channel strip metaphor in terms of performance. Traditionally, music mixing consoles employ a channels strip control metaphor for adjusting parameters such as volume and panning of each track. An alternative control metaphor, the so-called stage meta...... is surprisingly similar and thus we are not able to detect any significant difference in performance between the two interfaces. Qualitative data however, suggests that the stage metaphor is largely favoured for its intuitive interaction - confirming earlier studies....

  20. slice of LEP beamtube with getter strip

    CERN Multimedia

    1989-01-01

    A section of the LEP beam pipe. This is the chamber in which LEP's counter-rotating electron and positron beams travel. It is made of lead-clad aluminium. The beams circulate in the oval cross-section part of the chamber. In the rectangular cross-section part, LEP's innovative getter-strip vacuum pump is installed. After heating to purify the surface of the getter, the strip acts like molecular sticky tape, trapping any stray molecules left behind after the accelerator's traditional vacuum pumps have done their job.

  1. Comparative characteristics of polystyrene scintillation strips

    International Nuclear Information System (INIS)

    Gapienko, V.A.; Denisov, A.G.; Mel'nikov, E.A.

    1992-01-01

    Results are provided for a study of the main characteristics of polystyrene scintillation strips with a cross-section of 200 x 10 mm with two different scintillation-additive compositions: 1.5% p-terphenyl + 0.01% POPOP and 1.5% p-terphenyl + 0.01% DBP. The mean light-attenuation lengths are 180 cm and 260 cm, respectively, for strips with POPOP and DBP. The emittances of the polystyrene scintillators with DBP and POPOP additives have a ratio of 0.8:1.0 as recorded by an FEU-110 photomultiplier. 2 refs., 1 fig., 2 tabs

  2. Wide Strip Casting Technology of Magnesium Alloys

    Science.gov (United States)

    Park, W.-J.; Kim, J. J.; Kim, I. J.; Choo, D.

    Extensive investigations relating to the production of high performance and low cost magnesium sheet by strip casting have been performed for the application to automotive parts and electronic devices. Research on magnesium sheet production technology started in 2004 by Research Institute of Industrial Science and Technology (RIST) with support of Pohang Iron and Steel Company (POSCO). POSCO has completed the world's first plant to manufacture magnesium coil. Another big project in order to develop wide strip casting technology for the automotive applications of magnesium sheets was started in succession.

  3. Asset Stripping in a Mature Market Economy

    DEFF Research Database (Denmark)

    Klarskov Jeppesen, Kim; Møller, Ulrik Gorm

    2011-01-01

    Purpose – The purpose of this paper is to document a Danish fraud scheme, in which a large number of limited companies were stripped of their assets leaving them with nothing but tax debt, eventually causing the Danish Tax and Customs Administration to lose large sums. Furthermore, the purpose...... indicates that asset stripping may take place in mature market economies to the extent that perpetrators are able to circumvent the corporate governance system by giving lawyers, public accountants and banks incentives to act less critically towards dubious business transactions. Research limitations...

  4. Evaluation of a portable urinary pH meter and reagent strips.

    Science.gov (United States)

    De Coninck, Vincent; Keller, Etienne Xavier; Rodríguez-Monsalve, María; Haymann, Jean-Philippe; Doizi, Steeve; Traxer, Olivier

    2018-04-27

    To evaluate a portable electronic pH meter and to put its accuracy in perspective with reagent strips read by a layperson, a healthcare professional and an electronic reading device. Based on a pre-analysis on 20 patients, a sample size of 77 urine aliquots from healthy volunteers was necessary to obtain sufficient study power. Measurements of urinary pH were obtained by use of reagent strips, a portable pH meter and a laboratory pH meter (gold standard). Reagents strips were read by a professional experienced in interpreting strips, a layperson, and an electronic strip reader. The mean matched pair difference between measurement methods was analyzed by the paired t-test. The degree of correlation and agreement were evaluated by the Pearson's correlation coefficient and Bland-Altman plots, respectively. The mean matched pair difference between the gold standard and all other pH measurement methods was the smallest with the portable electronic pH meter (bias 0.01, 95% CI -0.07 to 0.08; p=0.89), followed by strips read by a professional (bias -0.09, 95% CI -0.21 to 0.02; p=0.10), layperson (bias -0.17, 95% CI -0.31 to -0.04; p=0.015) and electronic strip reader (bias -0.29, 95% CI -0.41 to -0.16; pmeter achieved the highest Pearson's correlation coefficient and narrowest 95% limits of agreement, followed by strip interpretation by a professional, the electronic strip reader and the layperson. In order to quantify the ability of pH measurement methods to correctly classify values within a predefined urinary pH target range, we performed classification tests for several stones. The portable electronic pH meter outperformed all other measurement methods for negative predictive values. Findings of the current study support that the portable electronic pH meter is a reliable pH measuring device. It seems to be more accurate compared to reagent strips readings.

  5. Silicon strip detector system for Fermilab E706

    Energy Technology Data Exchange (ETDEWEB)

    Engels, E Jr; Mani, S; Plants, D; Shepard, P F; Wilkins, R [Pittsburgh Univ., PA (USA); Hossain, S [Northeastern Univ., Boston, MA (USA)

    1984-09-15

    Fermilab Experiment E706 is an experiment to study direct photon production in hadron-hadron collisions at the Fermilab Tevatron II. A part of the charged particle spectrometer is a silicon strip detector system used to determine the position of interaction vertices in the production target and to provide angular formation about the secondary hadrons produced in a collision. We present some design criteria, as well as the results of tests of a wafer similar to those to be used in the experiment.

  6. Soybean growth on fly ash-amended strip mine soils

    Energy Technology Data Exchange (ETDEWEB)

    Fail, Jr, J L; Wochok, Z S

    1977-01-01

    The use of fly ash as an amendment for strip mine soils has been studied under field conditions. Soils ranging in pH from 4.0 to 6.0 were tested. The addition of fly ash in all cases was effective as an acid soil neutralizer and substantially enhanced the growth and development of all experimental plants. The parameters used in growth analyses were plant height, dry weight, root/shoot ratios, nodulation, pod production, and nitrogen fixing capacity for legumes.

  7. Traditional preventive treatment options

    DEFF Research Database (Denmark)

    Longbottom, C; Ekstrand, K; Zero, D

    2009-01-01

    Preventive treatment options can be divided into primary, secondary and tertiary prevention techniques, which can involve patient- or professionally applied methods. These include: oral hygiene (instruction), pit and fissure sealants ('temporary' or 'permanent'), fluoride applications (patient...... options....

  8. Breast Cancer: Treatment Options

    Science.gov (United States)

    ... Breast Cancer > Breast Cancer: Treatment Options Request Permissions Breast Cancer: Treatment Options Approved by the Cancer.Net Editorial ... can be addressed as quickly as possible. Recurrent breast cancer If the cancer does return after treatment for ...

  9. Linear sweep anodic stripping voltammetry: Determination of ...

    Indian Academy of Sciences (India)

    The aim of this work is to determine Cr(VI) in water resources by anodic stripping voltammetry using SPE-. AuNPs modified electrode .... surface area about 4 fold). 3.2 Optimization of Parameters ..... in water samples. The above system offers a.

  10. Physical distribution of oak strip flooring 1969

    Science.gov (United States)

    William C. Miller; William C. Miller

    1971-01-01

    As an aid to the marketing of oak strip flooring, a study was made of the distribution process for this product, from manufacture to consumer-where the flooring came from, where it went, how much was shipped, and who handled it.

  11. The Advantages of Lateral Tarsal Strip Procedure

    African Journals Online (AJOL)

    Generally in surgery, an ideal operation should be effective, cause minimal discomfort and morbidity, give an aesthetic result, and have a lasting effect.[4]. Lateral strip procedure (LSP) has those characteristics and it does restore normal lid function and give a rapid rehabilitation with few complications and excellent.

  12. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1980-01-01

    An improved and novel grid spacer for maintaining the fuel rods of a nuclear reactor fuel assembly in substantially parallel array is described. The invention provides for spring strips to maintain the fuel elements in their desired orientation which have more positive alignment than previous types while allowing greater flexibility to counterbalance the effects of differential thermal expansion. (UK)

  13. KRITIK SOSIAL DALAM KOMIK STRIP PAK BEI

    Directory of Open Access Journals (Sweden)

    Yudhi Novriansyah

    2016-08-01

    Full Text Available This research aimed to do interpret the marking which flange social criticism and know laboring ideology in story of Comic Strip Pak Bei. Research based on theory of structural semiotic according to Ferdinand De Saussure. Using analysis of Syntagmatic as first level of meaning to the text network and also picture, and analysis of Paradigmatic as second level of meaning or implicit meaning (connota-tion, myth, ideology Analysis done to six Comic choice edition of Strip Pak Bei period of November 2004 - Februari 2005 which tend to flange social criticism. At band of syntagmatic, result of research indicate that story theme lifted from social problems that happened in major society. The fact clear progressively when connected by Intertextual with information and texts which have preexisted. At band of Paradigmatic, social criticism tend to emerge dimly, is not transparent. Because of Comic Strip Pak Bei expand in the middle of Java cultural domination that developing myth of criticize as action menacing compatibility and orderliness of society. Story of Comic Strip Pak Bei also confirm dominant ideology in Java society culture, namely ideology of Patriarkhi and Feudalism which still go into effect until now. This prove ideology idea according to Louis Althusser which not again opposition between class, but have been owned and practiced by all social class.

  14. Polymer Inclusion Membranes with Strip Dispersion

    Directory of Open Access Journals (Sweden)

    Yueh-Hsien Li

    2017-06-01

    Full Text Available The present work investigated the permeation of indium ions through a polymer inclusion membrane (PIM, prepared with cellulose triacetate (CTA as the base polymer, tris(2-butoxyethyl phosphate (TBEP as the plasticizer and di-(2-ethylhexylphosphoric acid (D2EHPA as the extractant. With 5 M HCl aqueous solution as the strip solution, we observed an initial indium permeability of 2.4 × 10−4 m/min. However, the permeability decreases with time, dropping to about 3.4 × 10−5 m/min after 200 min of operation. Evidence was obtained showing that hydrolysis of CTA occurred, causing a dramatic decrease in the feed pH (protons transported from strip to feed solutions and a loss of extractant and plasticizer from the membrane, and then leading to the loss of indium permeability. To alleviate the problem of hydrolysis, we proposed an operation scheme called polymer inclusion membranes with strip dispersion: dispersing the strip solution in extractant-containing oil and then bringing the dispersion to contact with the polymer membrane. Since the strong acid was dispersed in oil, the membrane did not directly contact the strong acid at all times, and membrane hydrolysis was thus alleviated and the loss of indium permeability was effectively prevented. With the proposed scheme, a stable indium permeability of 2.5 × 10−4 m/min was obtained during the whole time period of the permeation experiment.

  15. Comic Strips to Accompany Science Museum Exhibits

    Science.gov (United States)

    Chung, Beom Sun; Park, Eun-mi; Kim, Sang-Hee; Cho, Sook-kyoung; Chung, Min Suk

    2016-01-01

    Science museums make the effort to create exhibits with amusing explanations. However, existing explanation signs with lengthy text are not appealing, and as such, visitors do not pay attention to them. In contrast, conspicuous comic strips composed of simple drawings and humors can attract science museum visitors. This study attempted to reveal…

  16. Ductility of reinforced concrete columns confined with stapled strips

    International Nuclear Information System (INIS)

    Tahir, M.F.; Khan, Q.U.Z.; Shabbir, F.; Sharif, M.B.; Ijaz, N.

    2015-01-01

    Response of three 150x150x450mm short reinforced concrete (RC) columns confined with different types of confining steel was investigated. Standard stirrups, strips and stapled strips, each having same cross-sectional area, were employed as confining steel around four comer column bars. Experimental work was aimed at probing into the affect of stapled strip confinement on post elastic behavior and ductility level under cyclic axial load. Ductility ratios, strength enhancement factor and core concrete strengths were compared to study the affect of confinement. Results indicate that strength enhancement in RC columns due to strip and stapled strip confinement was not remarkable as compared to stirrup confined column. It was found that as compared to stirrup confined column, stapled strip confinement enhanced the ductility of RC column by 183% and observed axial capacity of stapled strip confined columns was 41 % higher than the strip confined columns. (author)

  17. Refuges, flower strips, biodiversity and agronomic interest.

    Science.gov (United States)

    Roy, Grégory; Wateau, Karine; Legrand, Mickaël; Oste, Sandrine

    2008-01-01

    Several arthropods are natural predators of pests, and they are able to reduce and control their population development. FREDON Nord Pas-de-Calais (Federation Regionate de Defense contre les Organismes Nuisibles = Regional Federation for Pest Control) has begun for a long time to form farmers to the recognition of beneficial arthropods and to show them their usefulness. These beneficial insects or arachnids are present everywhere, in orchards and even in fields which are areas relatively poor in biodiversity. Adults feed in the flower strips instead larvae and some adults feed on preys such as aphids or caterpillars. Most of the time, beneficial insects can regulate pest but sometimes, in agricultural area, they can't make it early enough and efficiently. Their action begin too late and there biodiversity and number are too low. It's possible to enhance their action by manipulating the ecological infrastructures, like sewing flower strips or installing refuges. Flower strips increase the density of natural enemies and make them be present earlier in the field in order to control pests. Refuges permit beneficial's to spend winter on the spot. So they're able to be active and to grow in number earlier. From 2004 to 2007, on the one hand, FREDON Nord Pas-de-Calais has developed a research program. Its purpose was to inventory practices and also tools and means available and to judge the advisability of using such or such beneficial refuge in orchards. On the second hand, it studied the impact in orchard of refuges on population of beneficial's and the difference there were between manufactured refuges and homemade refuges. Interesting prospects were obtained with some of them. Otherwise, since 2003, FREDON has studied flower strips influence on beneficial population and their impact on pest control. In cabbage fields, results of trials have shown that flower strips lead to a reduction of aphid number under acceptable economic level, up to 50 meters from flower strips

  18. Parallel superconducting strip-line detectors: reset behaviour in the single-strip switch regime

    International Nuclear Information System (INIS)

    Casaburi, A; Heath, R M; Tanner, M G; Hadfield, R H; Cristiano, R; Ejrnaes, M; Nappi, C

    2014-01-01

    Superconducting strip-line detectors (SSLDs) are an important emerging technology for the detection of single molecules in time-of-flight mass spectrometry (TOF-MS). We present an experimental investigation of a SSLD laid out in a parallel configuration, designed to address selected single strip-lines operating in the single-strip switch regime. Fast laser pulses were tightly focused onto the device, allowing controllable nucleation of a resistive region at a specific location and study of the subsequent device response dynamics. We observed that in this regime, although the strip-line returns to the superconducting state after triggering, no effective recovery of the bias current occurs, in qualitative agreement with a phenomenological circuit simulation that we performed. Moreover, from theoretical considerations and by looking at the experimental pulse amplitude distribution histogram, we have the first confirmation of the fact that the phenomenological London model governs the current redistribution in these large area devices also after detection events. (paper)

  19. Numerical Analysis of Effectiveness of Strengthening Concrete Slab in Tension of the Steel-Concrete Composite Beam Using Pretensioned CFRP Strips

    Directory of Open Access Journals (Sweden)

    Jankowiak Iwona

    2017-12-01

    Full Text Available One of the methods to increase the load carrying capacity of the reinforced concrete (RC structure is its strengthening by using carbon fiber (CFRP strips. There are two methods of strengthening using CFRP strips - passive method and active method. In the passive method a strip is applied to the concrete surface without initial strains, unlike in the active method a strip is initially pretensioned before its application. In the case of a steel-concrete composite beam, strips may be used to strengthen the concrete slab located in the tension zone (in the parts of beams with negative bending moments. The finite element model has been developed and validated by experimental tests to evaluate the strengthening efficiency of the composite girder with pretensioned CFRP strips applied to concrete slab in its tension zone.

  20. Numerical Analysis of Effectiveness of Strengthening Concrete Slab in Tension of the Steel-Concrete Composite Beam Using Pretensioned CFRP Strips

    Science.gov (United States)

    Jankowiak, Iwona; Madaj, Arkadiusz

    2017-12-01

    One of the methods to increase the load carrying capacity of the reinforced concrete (RC) structure is its strengthening by using carbon fiber (CFRP) strips. There are two methods of strengthening using CFRP strips - passive method and active method. In the passive method a strip is applied to the concrete surface without initial strains, unlike in the active method a strip is initially pretensioned before its application. In the case of a steel-concrete composite beam, strips may be used to strengthen the concrete slab located in the tension zone (in the parts of beams with negative bending moments). The finite element model has been developed and validated by experimental tests to evaluate the strengthening efficiency of the composite girder with pretensioned CFRP strips applied to concrete slab in its tension zone.

  1. Distributed Energy Implementation Options

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Chandralata N [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-13

    This presentation covers the options for implementing distributed energy projects. It distinguishes between options available for distributed energy that is government owned versus privately owned, with a focus on the privately owned options including Energy Savings Performance Contract Energy Sales Agreements (ESPC ESAs). The presentation covers the new ESPC ESA Toolkit and other Federal Energy Management Program resources.

  2. Advection endash diffusion past a strip. II. Oblique incidence

    International Nuclear Information System (INIS)

    Knessl, C.; Keller, J.B.

    1997-01-01

    Advection and diffusion of particles past an impenetrable strip is considered when the strip is oblique to the advection or drift velocity. The particle concentration p(x,y) is determined asymptotically for large values of vL/D, where v is the drift velocity, D is the diffusion coefficient, and 2L is the width of the strip. The results complement those of Part I, which treated a strip normal to the drift velocity. copyright 1997 American Institute of Physics

  3. Flat Plate Boundary Layer Stimulation Using Trip Wires and Hama Strips

    Science.gov (United States)

    Peguero, Charles; Henoch, Charles; Hrubes, James; Fredette, Albert; Roberts, Raymond; Huyer, Stephen

    2017-11-01

    Water tunnel experiments on a flat plate at zero angle of attack were performed to investigate the effect of single roughness elements, i.e., trip wires and Hama strips, on the transition to turbulence. Boundary layer trips are traditionally used in scale model testing to force a boundary layer to transition from laminar to turbulent flow at a single location to aid in scaling of flow characteristics. Several investigations of trip wire effects exist in the literature, but there is a dearth of information regarding the influence of Hama strips on the flat plate boundary layer. The intent of this investigation is to better understand the effects of boundary layer trips, particularly Hama strips, and to investigate the pressure-induced drag of both styles of boundary layer trips. Untripped and tripped boundary layers along a flat plate at a range of flow speeds were characterized with multiple diagnostic measurements in the NUWC/Newport 12-inch water tunnel. A wide range of Hama strip and wire trip thicknesses were used. Measurements included dye flow visualization, direct skin friction and parasitic drag force, boundary layer profiles using LDV, wall shear stress fluctuations using hot film anemometry, and streamwise pressure gradients. Test results will be compared to the CFD and boundary layer model results as well as the existing body of work. Conclusions, resulting in guidance for application of Hama strips in model scale experiments and non-dimensional predictions of pressure drag will be presented.

  4. THE ECONOMICS OF INDUCED BREEDING OF Heterobranchus longifilis (VALENCIENNES, 1840 USING HORMONAL INDUCTION AND MANUAL STRIPPING

    Directory of Open Access Journals (Sweden)

    Anderson Nwalozie NWACHUKWU

    2014-04-01

    Full Text Available The economics of two induced breeding methods-hormonal induction and manual stripping were evaluated. In a 1:1 male: female ratio. Three (3 trials were made in each method using spawners weighing 1.5kg each. In the hormonal trial, 0.5ml ovaprim was injected into each spawner and both placed in a breeding tank containing aerated water 10 cm deep. Spawning occurred overnight and eggs incubated at 260C. In the stripping method, eggs were obtained from the female by gentle pressure on the abdomen and fertilized with milt from the macerated testes of the male partner, incubated in another tank containing aerated water 10 cm deep at 260C. Hatching occurred 25 hours later in both tanks. Fingerlings raised were harvested on the 30th day with mean counts of 509 and 3,032 in the hormonal and stripping methods, respectively. Statistical analysis using the least significant difference test (LSD showed that there was a significant difference (p<0.05 between the mean effect of the treatments. Economic analysis showed a loss of N9,089.00 and a profit of N64,600.00 with mean cost-returns ratios of 0.30 and 1.6 in the hormonal and stripping methods, respectively. It was therefore recommended that farmers use the stripping method in producing Heterobranchus lonifilis fingerlings. [Read full article] [Citation

  5. Study of the granular electromagnetic calorimeter with PPDs and scintillator strips for ILC

    Energy Technology Data Exchange (ETDEWEB)

    Kotera, Katsushige, E-mail: coterra@azusa.shinshu-u.ac.j [Shinshu University, Asahi 3-1-1, Matsumoto 390-8621 (Japan)

    2011-02-01

    A prototype module of a fine-granular electromagnetic calorimeter has been constructed by the CALICE collaboration and tested in the period August-September 2008 at the FNAL meson beam test facility. The calorimeter is one of the proposed concepts for a highly granular electromagnetic calorimeter for the International Linear Collider (ILC) experiment, which is designed to have an effective 10 mmx10 mm lateral segmentation using 10 mmx45 mm scintillator strips. The strips in the 15 odd layers are orthogonal with respect to those in the 15 even layers. A total of 2160 strip scintillators are individually read out using a Pixelated Photon Detector (PPD) or MPPC. As a preliminary result of the first stage analysis, we obtain a relative energy resolution for single electrons of {sigma}{sub E}/E=(15.15{+-}0.03)%/{radical}(E{sub beam}(GeV))+(1.44{+-}0.02)%, the quoted uncertainties are purely statistical.

  6. Rapid, quantitative and sensitive immunochromatographic assay based on stripping voltammetric detection of a metal ion label

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Fang; Wang, Kaihua; Lin, Yuehe

    2005-10-10

    A novel, sensitive immunochromatographic electrochemical biosensor (IEB) which combines an immunochromatographic strip technique with an electrochemical detection technique is demonstrated. The IEB takes advantages of the speed and low-cost of the conventional immunochromatographic test kits and high-sensitivity of stripping voltammetry. Bismuth ions (Bi3+) have been coupled with the antibody through the bifunctional chelating agent diethylenetriamine pentaacetic acid (DTPA). After immunoreactions, Bi3+ was released and quantified by anodic stripping voltammetry at a built-in single-use screen-printed electrode. As an example for the applications of such novel device, the detection of human chorionic gonadotronphin (HCG) in a specimen was performed. This biosensor provides a more user-friendly, rapid, clinically accurate, and less expensive immunoassay for such analysis in specimens than currently available test kits.

  7. Method of making steel strapping and strip

    Energy Technology Data Exchange (ETDEWEB)

    Robert D. Reilly

    2000-02-16

    The technical progress obtained for this time frame consisted of the awarding of two contracts for determination of metallurgical parameters for heat treatment of strapping and strip which are unavailable from current technology and/or published data in this field. The two contractors were Bricmont, Inc. and the Department of Materials Science and Engineering at the Technological Institute of Northwestern University, Evanston, IL. Phase 1 of the two stage contract with Bricmont, Inc. which provided a computer analysis of the cooling rates of a typical range of thickness' of strapping was completed. This study was developed for the purpose of determining the time parameters for quenching low carbon steels to a martensitic microstructure within the time frame of the design of the proposed process. It also provides design criteria for cooling to ambient for the total process. This data is required for Phase 2 of the Bricmont proposal which completes the design and specifications of the total heat treating and cooling system for the process. This becomes the basis for developing the cost and space requirements for this component of the production line. The authors do not intend to award Phase 2 until the work done at Northwestern University discussed hereafter is completed. On or about May 1, 1999 a contract for a project entitled ``Effects of Steel Composition and Quench Rate on Microstructure and Mechanical Properties of Strapping'' to be performed at the Department of Materials Science and Engineering was awarded. The delay in initiating this project was due to the legal interpretation and final agreement of the intellectual provisions of the award by the author's attorneys, Northwestern's attorneys and the legal representative in the Chicago office of the DOE. The work to date includes rapid quenching of a number of different steel compositions and microstructure on an existing drop quench test apparatus. It was initially assumed that this

  8. 7 CFR 29.6128 - Straight Stripped (X Group).

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Straight Stripped (X Group). 29.6128 Section 29.6128... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.6128 Straight Stripped (X Group). This group consists of..., and tolerances X1 Fine Quality Straight Stripped. Heavy, ripe, firm, semielastic, normal strength and...

  9. TANK SPACE OPTIONS REPORT

    International Nuclear Information System (INIS)

    Willis, W.L.; Ahrendt, M.R.

    2009-01-01

    Since this report was originally issued in 2001, several options proposed for increasing double-shell tank (DST) storage space were implemented or are in the process of implementation. Changes to the single-shell tank (SST) waste retrieval schedule, completion of DST space saving options, and the DST space saving options in progress have delayed the projected shortfall of DST storage space from the 2007-2011 to the 2018-2025 timeframe (ORP-11242, River Protection Project System Plan). This report reevaluates options from Rev. 0 and includes evaluations of new options for alleviating projected restrictions on SST waste retrieval beginning in 2018 because of the lack of DST storage space.

  10. INVESTIGATION OF CLINOPTILOLITE NATURAL ZEOLITE REGENERATION BY AIR STRIPPING FOLLOWED BY ION EXCHANGE FOR REMOVAL OF AMMONIUM FROM AQUEOUS SOLUTIONS

    Directory of Open Access Journals (Sweden)

    A. R. Rahmani ، M. T. Samadi ، H. R. Ehsani

    2009-07-01

    Full Text Available The purpose of this study was to regenerate clinoptilolite natural zeolite by air stripping followed by removal of ammonium from aqueous solutions. The research was carried out in continuous system. The characteristics of graded clinoptilolite from Semnan (one of the central provinces in Iran mines were determined and then regeneration tests were done by contacting of 1 N NaCl solution with given weights of ammonium saturated zeolite. Then the brine of column was transferred to the air stripping column for regeneration. The pH of brine solution before entrance to a stripping column was increased to 11. Air stripped ammonia from the brine was converted to the ammonium ion by using acid scrubber. The outlet effluent from stripping column was collected for reuse. The results showed that the cation exchange capacities were 17.31 to 18.38 mg NH4+/g of zeolite weight. Regeneration efficiency of zeolite by NaCl solution and air stripping was in the range of 92%-97% under various operational conditions. However, the efficiency of acid absorption of released ammonia in stripping process was 55% with a major rejection of the surplus ammonia to the atmosphere. It could be concluded that the method studied may be considered as an advanced and supplementary process for treating effluents of aqueous solution and fishponds in existing treatment plants.

  11. The extent of the stop coannihilation strip

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, John [King' s College London, Theoretical Particle Physics and Cosmology Group, Department of Physics, London (United Kingdom); CERN, Theory Division, Geneva 23 (Switzerland); Olive, Keith A. [University of Minnesota, School of Physics and Astronomy, Minneapolis, MN (United States); University of Minnesota, William I. Fine Theoretical Physics Institute, School of Physics and Astronomy, Minneapolis, MN (United States); Zheng, Jiaming [University of Minnesota, School of Physics and Astronomy, Minneapolis, MN (United States)

    2014-07-15

    Many supersymmetric models such as the constrained minimal supersymmetric extension of the Standard Model (CMSSM) feature a strip in parameter space where the lightest neutralino χ is identified as the lightest supersymmetric particle, the lighter stop squark t{sub 1} is the next-to-lightest supersymmetric particle (NLSP), and the relic χ cold darkmatter density is brought into the range allowed by astrophysics and cosmology by coannihilation with the lighter stop squark t{sub 1} NLSP. We calculate the stop coannihilation strip in the CMSSM, incorporating Sommerfeld enhancement effects, and we explore the relevant phenomenological constraints and phenomenological signatures. In particular, we show that the t{sub 1} may weigh several TeV, and its lifetime may be in the nanosecond range, features that are more general than the specific CMSSM scenarios that we study in this paper. (orig.)

  12. L-strip proximity fed ga

    Directory of Open Access Journals (Sweden)

    Ashish Singh

    2014-03-01

    Full Text Available In this article, the analysis of dualband L-strip fed compact semi-circular disk microstrip patch antenna has been presented using circuit theory concept. The antenna parameters such as return loss, VSWR and radiation pattern are calculated. The effect of geometric dimensions of the proposed antenna such as length of vertical and horizontal portion of L-strip is investigated. It is found that antenna resonate at two distinct modes i.e. 1.3 GHz and 6.13 GHz for lower and upper resonance frequencies respectively. The bandwidth of the proposed antenna at lower resonance frequency is 6.61% (simulated and 10.64% (theoretical whereas at upper resonance frequency, it is 6.02% (simulated and 9.06 % (theoretical. The theoretical results are compared with IE3D simulation results as well as experimental results and they are in close agreement.

  13. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1980-01-01

    An improved and novel grid spacer was developed for use in nuclear reactor fuel assemblies. It is comprised of a series of intersecting support strips and a peripheral support band attached to the ends of the support strips. Each of the openings into which the fuel element is inserted has a number of protruding dimples and springs extending in different directions. The dimples coact with the springs to secure the fuel rods in the openings. Compared with previous designs, this design gives more positive alignment of the support stips while allowing greater flexibility to counterbalance the effects of thermal expansion. The springs are arranged in alternating directions so that the reaction forces tend to counterbalance each other, which in turn minimizes the reaction loads on the supporting structure. (D.N.)

  14. Electron capture by highly stripped ions

    International Nuclear Information System (INIS)

    Greenland, P.T.

    1981-06-01

    This review describes theories of electron capture suitable for the description of rearrangement collisions between atomic hydrogen and completely stripped projectiles with charge greater than unity. The region of impact velocity considered lies between 0.05 and 3 au, which is of technological importance in fusion power devices. The semiclassical, impact parameter formalism is discussed and the use of atomic expansions at medium impact velocity is described. Experimental results for both completely and partially stripped projectiles are reviewed. The use of a molecular basis at low energy, and the role of pseudocrossings peculiar to the two centre Coulomb interaction are described. Finally, purely classical techniques, in which the electron wavefunction is represented by an ensemble of Kepler orbits are considered. The review was completed in February 1981. (author)

  15. Continuous liquid sheet generator for ion stripping

    International Nuclear Information System (INIS)

    Gavin, B.; Batson, P.; Leemann, B.; Rude, B.

    1984-10-01

    Many of the technical problems of generating a large thin liquid sheet from 0.02 to 0.20 μm thick (3 to 40 μgm/cm 2 ) have been solved. It is shown that this perennial sheet is stable and consonant in dimension. Several ion beam species from the SuperHILAC have been used for evaluation; at 0.11 MeV/n. In one of three modes this sheet serves as an equivalent substitute for a carbon foil. The second mode is characterized by a solid-like charge state distribution but with a varying fraction of unstripped ions. The third mode gives stripping performance akin to a vapor stripping medium. 9 references, 7 figures

  16. Low-resistance strip sensors for beam-loss event protection

    International Nuclear Information System (INIS)

    Ullán, M.; Benítez, V.; Quirion, D.; Zabala, M.; Pellegrini, G.; Lozano, M.; Lacasta, C.; Soldevila, U.; García, C.; Fadeyev, V.; Wortman, J.; DeFilippis, J.; Shumko, M.; Grillo, A.A; Sadrozinski, H.F.-W.

    2014-01-01

    AC-coupled silicon strip sensors can be damaged in case of a beam loss due to the possibility of a large charge accumulation in the bulk, developing very high voltages across the coupling capacitors which can destroy them. Punch-through structures are currently used to avoid this problem helping to evacuate the accumulated charge as large voltages are developing. Nevertheless, previous experiments, performed with laser pulses, have shown that these structures can become ineffective in relatively long strips. The large value of the implant resistance can effectively isolate the “far” end of the strip from the punch-through structure leading to large voltages. We present here our developments to fabricate low-resistance strip sensors to avoid this problem. The deposition of a conducting material in contact with the implants drastically reduces the strip resistance, assuring the effectiveness of the punch-through structures. First devices have been fabricated with this new technology. Initial results with laser tests show the expected reduction in peak voltages on the low resistivity implants. Other aspects of the sensor performance, including the signal formation, are not affected by the new technology

  17. Design of the first full size ATLAS ITk Strip sensor for the endcap region

    CERN Document Server

    Lacasta, Carlos; The ATLAS collaboration

    2017-01-01

    The ATLAS collaboration is designing the full silicon tracker (ITk) that will operate in the HL-LHC replacing the current design. The silicon microstrip sensors for the barrel and the endcap regions in the ITk are fabricated in 6 inch, p-type, float-zone wafers, where large-area strip sensor designs are laid out together with a number of miniature sensors. The radiation tolerance and specific system issues like the need for slim edge of 450 µm have been tested with square shaped sensors intended for the barrel part of the tracker. This work presents the design of the first full size silicon microstrip sensor for the endcap region with a slim edge of 450 µm. The strip endcaps will consist of several wheels with two layers of silicon strip sensors each. The strips have to lie along the azimuthal direction, apart from a small stereo angle rotation (20 mrad on each side, giving 40 mrad total) for measuring the second coordinate of tracks. This stereo angle is built into the strip layout of the sensor and, in or...

  18. Investigation of HV/HR-CMOS technology for the ATLAS Phase-II Strip Tracker Upgrade

    International Nuclear Information System (INIS)

    Fadeyev, V.; Galloway, Z.; Grabas, H.; Grillo, A.A.; Liang, Z.; Martinez-Mckinney, F.; Seiden, A.; Volk, J.; Affolder, A.; Buckland, M.; Meng, L.; Arndt, K.; Bortoletto, D.; Huffman, T.; John, J.; McMahon, S.; Nickerson, R.; Phillips, P.; Plackett, R.; Shipsey, I.

    2016-01-01

    ATLAS has formed strip CMOS project to study the use of CMOS MAPS devices as silicon strip sensors for the Phase-II Strip Tracker Upgrade. This choice of sensors promises several advantages over the conventional baseline design, such as better resolution, less material in the tracking volume, and faster construction speed. At the same time, many design features of the sensors are driven by the requirement of minimizing the impact on the rest of the detector. Hence the target devices feature long pixels which are grouped to form a virtual strip with binary-encoded z position. The key performance aspects are radiation hardness compatibility with HL-LHC environment, as well as extraction of the full hit position with full-reticle readout architecture. To date, several test chips have been submitted using two different CMOS technologies. The AMS 350 nm is a high voltage CMOS process (HV-CMOS), that features the sensor bias of up to 120 V. The TowerJazz 180 nm high resistivity CMOS process (HR-CMOS) uses a high resistivity epitaxial layer to provide the depletion region on top of the substrate. We have evaluated passive pixel performance, and charge collection projections. The results strongly support the radiation tolerance of these devices to radiation dose of the HL-LHC in the strip tracker region. We also describe design features for the next chip submission that are motivated by our technology evaluation.

  19. Investigation of HV/HR-CMOS technology for the ATLAS Phase-II Strip Tracker Upgrade

    Science.gov (United States)

    Fadeyev, V.; Galloway, Z.; Grabas, H.; Grillo, A. A.; Liang, Z.; Martinez-Mckinney, F.; Seiden, A.; Volk, J.; Affolder, A.; Buckland, M.; Meng, L.; Arndt, K.; Bortoletto, D.; Huffman, T.; John, J.; McMahon, S.; Nickerson, R.; Phillips, P.; Plackett, R.; Shipsey, I.; Vigani, L.; Bates, R.; Blue, A.; Buttar, C.; Kanisauskas, K.; Maneuski, D.; Benoit, M.; Di Bello, F.; Caragiulo, P.; Dragone, A.; Grenier, P.; Kenney, C.; Rubbo, F.; Segal, J.; Su, D.; Tamma, C.; Das, D.; Dopke, J.; Turchetta, R.; Wilson, F.; Worm, S.; Ehrler, F.; Peric, I.; Gregor, I. M.; Stanitzki, M.; Hoeferkamp, M.; Seidel, S.; Hommels, L. B. A.; Kramberger, G.; Mandić, I.; Mikuž, M.; Muenstermann, D.; Wang, R.; Zhang, J.; Warren, M.; Song, W.; Xiu, Q.; Zhu, H.

    2016-09-01

    ATLAS has formed strip CMOS project to study the use of CMOS MAPS devices as silicon strip sensors for the Phase-II Strip Tracker Upgrade. This choice of sensors promises several advantages over the conventional baseline design, such as better resolution, less material in the tracking volume, and faster construction speed. At the same time, many design features of the sensors are driven by the requirement of minimizing the impact on the rest of the detector. Hence the target devices feature long pixels which are grouped to form a virtual strip with binary-encoded z position. The key performance aspects are radiation hardness compatibility with HL-LHC environment, as well as extraction of the full hit position with full-reticle readout architecture. To date, several test chips have been submitted using two different CMOS technologies. The AMS 350 nm is a high voltage CMOS process (HV-CMOS), that features the sensor bias of up to 120 V. The TowerJazz 180 nm high resistivity CMOS process (HR-CMOS) uses a high resistivity epitaxial layer to provide the depletion region on top of the substrate. We have evaluated passive pixel performance, and charge collection projections. The results strongly support the radiation tolerance of these devices to radiation dose of the HL-LHC in the strip tracker region. We also describe design features for the next chip submission that are motivated by our technology evaluation.

  20. Design of the first full size ATLAS ITk Strip sensor for the endcap region

    CERN Document Server

    Lacasta, Carlos; The ATLAS collaboration

    2018-01-01

    The ATLAS collaboration is designing the full silicon tracker (ITk) that will operate in the HL-LHC replacing the current design. The silicon microstrip sensors for the barrel and the endcap regions in the ITk are fabricated in 6 inch, p-type, float-zone wafers, where large-area strip sensor designs are laid out together with a number of miniature sensors. The radiation tolerance and specific system issues like the need for slim edge of 450 μm have been tested with square shaped sensors intended for the barrel part of the tracker. This work presents the design of the first full size silicon microstrip sensor for the endcap region with a slim edge of 450 μm. The strip endcaps will consist of several wheels with two layers of silicon strip sensors each. The strips have to lie along the azimuthal direction, apart from a small stereo angle rotation (20 mrad on each side, giving 40 mrad total) for measuring the second coordinate of tracks. This stereo angle is built into the strip layout of the sensor and, in or...

  1. Investigation of HV/HR-CMOS technology for the ATLAS Phase-II Strip Tracker Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Fadeyev, V., E-mail: fadeyev@ucsc.edu [Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA 95064 (United States); Galloway, Z.; Grabas, H.; Grillo, A.A.; Liang, Z.; Martinez-Mckinney, F.; Seiden, A.; Volk, J. [Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA 95064 (United States); Affolder, A.; Buckland, M.; Meng, L. [Department of Physics, University of Liverpool, O. Lodge Laboratory, Oxford Street, Liverpool L69 7ZE (United Kingdom); Arndt, K.; Bortoletto, D.; Huffman, T.; John, J.; McMahon, S.; Nickerson, R.; Phillips, P.; Plackett, R.; Shipsey, I. [Department of Physics, Oxford University, Oxford (United Kingdom); and others

    2016-09-21

    ATLAS has formed strip CMOS project to study the use of CMOS MAPS devices as silicon strip sensors for the Phase-II Strip Tracker Upgrade. This choice of sensors promises several advantages over the conventional baseline design, such as better resolution, less material in the tracking volume, and faster construction speed. At the same time, many design features of the sensors are driven by the requirement of minimizing the impact on the rest of the detector. Hence the target devices feature long pixels which are grouped to form a virtual strip with binary-encoded z position. The key performance aspects are radiation hardness compatibility with HL-LHC environment, as well as extraction of the full hit position with full-reticle readout architecture. To date, several test chips have been submitted using two different CMOS technologies. The AMS 350 nm is a high voltage CMOS process (HV-CMOS), that features the sensor bias of up to 120 V. The TowerJazz 180 nm high resistivity CMOS process (HR-CMOS) uses a high resistivity epitaxial layer to provide the depletion region on top of the substrate. We have evaluated passive pixel performance, and charge collection projections. The results strongly support the radiation tolerance of these devices to radiation dose of the HL-LHC in the strip tracker region. We also describe design features for the next chip submission that are motivated by our technology evaluation.

  2. Flexural Strengthening of RC Slabs with Prestressed CFRP Strips Using Different Anchorage Systems

    Directory of Open Access Journals (Sweden)

    José Sena-Cruz

    2015-10-01

    Full Text Available Externally Bonded Reinforcement (EBR technique has been widely used for flexural strengthening of concrete structures by using carbon fiber-reinforced polymers (CFRP. EBR technique offers several structural advantages when the CFRP material is prestressed. This paper presents an experimental and numerical study on reinforced (RC slabs strengthened in flexure with prestressed CFRP strips as a structural strengthening system. The strips are applied as an externally bonded reinforcement (EBR and anchored with either a mechanical or a gradient anchorage. The former foresees metallic anchorage plates fixed to the concrete substrate, while the latter is based on an accelerated epoxy resin curing followed by a segment-wise prestress force decrease at the strip ends. Both anchorage systems, in combination with different CFRP strip geometries, were subjected to static loading tests. It could be demonstrated that the composite strip’s performance is better exploited when prestressing is used, with slightly higher overall load carrying capacities for mechanical anchorages than for the gradient anchorage. The performed investigations by means of a cross-section analysis supported the experimental observation that in case a mechanical anchorage is used, progressive strip debonding changes the fully bonded configuration to an unbonded end-anchored system. The inclusion of defined debonding criteria for both the anchorage zones and free length between the anchorage regions allowed to precisely capture the ultimate loading forces.

  3. Development Of Chemical Reduction And Air Stripping Processes To Remove Mercury From Wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Dennis G.; Looney, Brian B.; Craig, Robert R.; Thompson, Martha C.; Kmetz, Thomas F.

    2013-07-10

    This study evaluates the removal of mercury from wastewater using chemical reduction and air stripping using a full-scale treatment system at the Savannah River Site. The existing water treatment system utilizes air stripping as the unit operation to remove organic compounds from groundwater that also contains mercury (C ~ 250 ng/L). The baseline air stripping process was ineffective in removing mercury and the water exceeded a proposed limit of 51 ng/L. To test an enhancement to the existing treatment modality a continuous dose of reducing agent was injected for 6-hours at the inlet of the air stripper. This action resulted in the chemical reduction of mercury to Hg(0), a species that is removable with the existing unit operation. During the injection period a 94% decrease in concentration was observed and the effluent satisfied proposed limits. The process was optimized over a 2-day period by sequentially evaluating dose rates ranging from 0.64X to 297X stoichiometry. A minimum dose of 16X stoichiometry was necessary to initiate the reduction reaction that facilitated the mercury removal. Competing electron acceptors likely inhibited the reaction at the lower 1 doses, which prevented removal by air stripping. These results indicate that chemical reduction coupled with air stripping can effectively treat large-volumes of water to emerging part per trillion regulatory standards for mercury.

  4. AgBufferBuilder: A geographic information system (GIS) tool for precision design and performance assessment of filter strips

    Science.gov (United States)

    M. G. Dosskey; S. Neelakantan; T. G. Mueller; T. Kellerman; M. J. Helmers; E. Rienzi

    2015-01-01

    Spatially nonuniform runoif reduces the water qua1iry perfortnance of constant- width filter strips. A geographic inlormation system (Gls)-based tool was developed and tested that ernploys terrain analysis to account lor spatially nonuniform runoffand produce more ellbctive filter strip designs.The computer program,AgBufTerBuilder, runs with ATcGIS versions 10.0 and 10...

  5. Large strip RPCs for the LEPS2 TOF system

    Energy Technology Data Exchange (ETDEWEB)

    Tomida, N., E-mail: natsuki@scphys.kyoto-u.ac.jp [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Niiyama, M. [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Ohnishi, H. [RIKEN (The Institute of Physical and Chemical Research), Wako, Saitama 351-0198 (Japan); Tran, N. [Research Center for Nuclear Physics (RCNP), Osaka University, Ibaraki, Osaka 567-0047 (Japan); Hsieh, C.-Y.; Chu, M.-L.; Chang, W.-C. [Institute of Physics, Academia Sinica, Nankang, Taipei 11529, Taiwan (China); Chen, J.-Y. [National Synchrotron Radiation Research Center (NSRRC), Hsinchu 30076, Taiwan (China)

    2014-12-01

    High time-resolution resistive plate chambers (RPCs) with large-size readout strips are developed for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. The experimental requirement is a 50-ps time resolution for a strip size larger than 100 cm{sup 2}/channel. We are able to achieve 50-ps time resolutions with 2.5×100 cm{sup 2} strips by directly connecting the amplifiers to strips. With the same time resolution, the number of front-end electronics (FEE) is also reduced by signal addition. - Highlights: • Find a way to achieve a good time resolution with a large strip RPC. • 2.5 cm narrow strips have better resolutions than 5.0 cm ones. • The 0.5 mm narrow strip interval shows flat time resolutions between strips. • FEEs directly connected to strips make the signal reflection at the strip edge small. • A time resolution of 50 ps was achieved with 2.5 cm×100 cm strips.

  6. Moving strip technique of electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Wakasa, Hiroyuki; Oguri, Nobuhiro; Kitayama, Takuichi; Nakagiri, Yoshitada; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1984-12-01

    The fieldsize in electron beam therapy is determined by the cone size. In case of skin metastasis of a malignant tumor and so on, which need a large field size and whose area is much larger than the size of the cone, a large field size is usually produced by dividing the portals. However, the dose distribution at the border of the field becomes unequal, and hot and cold dose areas are produced according to the distance between portals. We tried the strip field technique in a large field along the long axis of the body in order to flatten the dose of the border employing the moving strip used for whole abdominal irradiation in ovarian cancer. We set the film in Mix-DP and used the strip field technique with 2.5cm steps. We discussed the relationship between the interval (distance between portals) and the flattening of the dose within the field. Skin movement due to breathing and influences on the flattening of the dose were considered. The proper flatness was obtained at depths of 0,1,2, and 3cm by setting the interval at 0.5cm. When skin movement was produced by breathing in +-1.5mm, the proper flaness was obtained also at a 0.5-cm interval. It seems that smoothing is increased by breathing. An ''electron beam moving strip'' with a 2.5-cm step and 0.5-cm interval was clinically effective in the treatment of patients with skin metastasis of colon cancer. (author).

  7. Ram pressure stripping of tilted galaxies

    Czech Academy of Sciences Publication Activity Database

    Jáchym, Pavel; Köppen, J.; Palouš, Jan; Combes, F.

    2009-01-01

    Roč. 500, č. 2 (2009), s. 693-703 ISSN 0004-6361 R&D Projects: GA MŠk(CZ) LC06014; GA ČR GP205/08/P556 Institutional research plan: CEZ:AV0Z10030501 Keywords : interstellar medium * clusters of galaxies * gas stripping Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 4.179, year: 2009

  8. The Gel Generator option

    International Nuclear Information System (INIS)

    Boyd, R.E.

    1999-01-01

    The development of a national policy for guaranteeing an ample supply of 99m Tc to nuclear medicine, involves issues which go beyond the means by which radioactivation is achieved. Indeed, in such an exercise the pragmatic dictates of business and the sensitivities of politics must also be taken into account. Furthermore where a preference towards the nuclear reactor or the potential of cyclotrons is being questioned, the debate is incomplete if the only options that are considered are the fission-based 99 Mo generator versus the direct cyclotron production of 99m Tc. There is a third option (also neutron γ-based), an alternative to the fission 99 Mo generator, which ought not be overlooked. The application of low specific activity (n,γ) 99 Mo to a new type of generator, the Gel Generator, has been the focus of much research, particularly in Australia and more recently in China. After the initial concept had been established in the laboratory, the Australian researchers then undertook a comprehensive program of tests on the Gel Generator to assess its potential, either in the clinical laboratory or the centralised radiopharmacy, for supplying 99m Tc suitable for nuclear medicine. The outcome of this program was a clear indication that the Gel Generator innovation had the capability to provide both technical and economic advantages to the nuclear medicine industry. These advantages are described. Since that time the Gel Generator has been selected for routine use in China where it now satisfies more than 30% of the 99m Tc demand. (author)

  9. Commissioning and Performance of the CMS Silicon Strip Tracker with Cosmic Ray Muons

    CERN Document Server

    Chatrchyan, S; Sirunyan, A M; Adam, W; Arnold, B; Bergauer, H; Bergauer, T; Dragicevic, M; Eichberger, M; Erö, J; Friedl, M; Frühwirth, R; Ghete, V M; Hammer, J; Hänsel, S; Hoch, M; Hörmann, N; Hrubec, J; Jeitler, M; Kasieczka, G; Kastner, K; Krammer, M; Liko, D; Magrans de Abril, I; Mikulec, I; Mittermayr, F; Neuherz, B; Oberegger, M; Padrta, M; Pernicka, M; Rohringer, H; Schmid, S; Schöfbeck, R; Schreiner, T; Stark, R; Steininger, H; Strauss, J; Taurok, A; Teischinger, F; Themel, T; Uhl, D; Wagner, P; Waltenberger, W; Walzel, G; Widl, E; Wulz, C E; Chekhovsky, V; Dvornikov, O; Emeliantchik, I; Litomin, A; Makarenko, V; Marfin, I; Mossolov, V; Shumeiko, N; Solin, A; Stefanovitch, R; Suarez Gonzalez, J; Tikhonov, A; Fedorov, A; Karneyeu, A; Korzhik, M; Panov, V; Zuyeuski, R; Kuchinsky, P; Beaumont, W; Benucci, L; Cardaci, M; De Wolf, E A; Delmeire, E; Druzhkin, D; Hashemi, M; Janssen, X; Maes, T; Mucibello, L; Ochesanu, S; Rougny, R; Selvaggi, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Adler, V; Beauceron, S; Blyweert, S; D'Hondt, J; De Weirdt, S; Devroede, O; Heyninck, J; Kalogeropoulos, A; Maes, J; Maes, M; Mozer, M U; Tavernier, S; Van Doninck, W; Van Mulders, P; Villella, I; Bouhali, O; Chabert, E C; Charaf, O; Clerbaux, B; De Lentdecker, G; Dero, V; Elgammal, S; Gay, A P R; Hammad, G H; Marage, P E; Rugovac, S; Vander Velde, C; Vanlaer, P; Wickens, J; Grunewald, M; Klein, B; Marinov, A; Ryckbosch, D; Thyssen, F; Tytgat, M; Vanelderen, L; Verwilligen, P; Basegmez, S; Bruno, G; Caudron, J; Delaere, C; Demin, P; Favart, D; Giammanco, A; Grégoire, G; Lemaitre, V; Militaru, O; Ovyn, S; Piotrzkowski, K; Quertenmont, L; Schul, N; Beliy, N; Daubie, E; Alves, G A; Pol, M E; Souza, M H G; Carvalho, W; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Mundim, L; Oguri, V; Santoro, A; Silva Do Amaral, S M; Sznajder, A; Fernandez Perez Tomei, T R; Ferreira Dias, M A; Gregores, E M; Novaes, S F; Abadjiev, K; Anguelov, T; Damgov, J; Darmenov, N; Dimitrov, L; Genchev, V; Iaydjiev, P; Piperov, S; Stoykova, S; Sultanov, G; Trayanov, R; Vankov, I; Dimitrov, A; Dyulendarova, M; Kozhuharov, V; Litov, L; Marinova, E; Mateev, M; Pavlov, B; Petkov, P; Toteva, Z; Chen, G M; Chen, H S; Guan, W; Jiang, C H; Liang, D; Liu, B; Meng, X; Tao, J; Wang, J; Wang, Z; Xue, Z; Zhang, Z; Ban, Y; Cai, J; Ge, Y; Guo, S; Hu, Z; Mao, Y; Qian, S J; Teng, H; Zhu, B; Avila, C; Baquero Ruiz, M; Carrillo Montoya, C A; Gomez, A; Gomez Moreno, B; Ocampo Rios, A A; Osorio Oliveros, A F; Reyes Romero, D; Sanabria, J C; Godinovic, N; Lelas, K; Plestina, R; Polic, D; Puljak, I; Antunovic, Z; Dzelalija, M; Brigljevic, V; Duric, S; Kadija, K; Morovic, S; Fereos, R; Galanti, M; Mousa, J; Papadakis, A; Ptochos, F; Razis, P A; Tsiakkouri, D; Zinonos, Z; Hektor, A; Kadastik, M; Kannike, K; Müntel, M; Raidal, M; Rebane, L; Anttila, E; Czellar, S; Härkönen, J; Heikkinen, A; Karimäki, V; Kinnunen, R; Klem, J; Kortelainen, M J; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Nysten, J; Tuominen, E; Tuominiemi, J; Ungaro, D; Wendland, L; Banzuzi, K; Korpela, A; Tuuva, T; Nedelec, P; Sillou, D; Besancon, M; Chipaux, R; Dejardin, M; Denegri, D; Descamps, J; Fabbro, B; Faure, J L; Ferri, F; Ganjour, S; Gentit, F X; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Lemaire, M C; Locci, E; Malcles, J; Marionneau, M; Millischer, L; Rander, J; Rosowsky, A; Rousseau, D; Titov, M; Verrecchia, P; Baffioni, S; Bianchini, L; Bluj, M; Busson, P; Charlot, C; Dobrzynski, L; Granier de Cassagnac, R; Haguenauer, M; Miné, P; Paganini, P; Sirois, Y; Thiebaux, C; Zabi, A; Agram, J L; Besson, A; Bloch, D; Bodin, D; Brom, J M; Conte, E; Drouhin, F; Fontaine, J C; Gelé, D; Goerlach, U; Gross, L; Juillot, P; Le Bihan, A C; Patois, Y; Speck, J; Van Hove, P; Baty, C; Bedjidian, M; Blaha, J; Boudoul, G; Brun, H; Chanon, N; Chierici, R; Contardo, D; Depasse, P; Dupasquier, T; El Mamouni, H; Fassi, F; Fay, J; Gascon, S; Ille, B; Kurca, T; Le Grand, T; Lethuillier, M; Lumb, N; Mirabito, L; Perries, S; Vander Donckt, M; Verdier, P; Djaoshvili, N; Roinishvili, N; Roinishvili, V; Amaglobeli, N; Adolphi, R; Anagnostou, G; Brauer, R; Braunschweig, W; Edelhoff, M; Esser, H; Feld, L; Karpinski, W; Khomich, A; Klein, K; Mohr, N; Ostaptchouk, A; Pandoulas, D; Pierschel, G; Raupach, F; Schael, S; Schultz von Dratzig, A; Schwering, G; Sprenger, D; Thomas, M; Weber, M; Wittmer, B; Wlochal, M; Actis, O; Altenhöfer, G; Bender, W; Biallass, P; Erdmann, M; Fetchenhauer, G; Frangenheim, J; Hebbeker, T; Hilgers, G; Hinzmann, A; Hoepfner, K; Hof, C; Kirsch, M; Klimkovich, T; Kreuzer, P; Lanske, D; Merschmeyer, M; Meyer, A; Philipps, B; Pieta, H; Reithler, H; Schmitz, S A; Sonnenschein, L; Sowa, M; Steggemann, J; Szczesny, H; Teyssier, D; Zeidler, C; Bontenackels, M; Davids, M; Duda, M; Flügge, G; Geenen, H; Giffels, M; Haj Ahmad, W; Hermanns, T; Heydhausen, D; Kalinin, S; Kress, T; Linn, A; Nowack, A; Perchalla, L; Poettgens, M; Pooth, O; Sauerland, P; Stahl, A; Tornier, D; Zoeller, M H; Aldaya Martin, M; Behrens, U; Borras, K; Campbell, A; Castro, E; Dammann, D; Eckerlin, G; Flossdorf, A; Flucke, G; Geiser, A; Hatton, D; Hauk, J; Jung, H; Kasemann, M; Katkov, I; Kleinwort, C; Kluge, H; Knutsson, A; Kuznetsova, E; Lange, W; Lohmann, W; Mankel, R; Marienfeld, M; Meyer, A B; Miglioranzi, S; Mnich, J; Ohlerich, M; Olzem, J; Parenti, A; Rosemann, C; Schmidt, R; Schoerner-Sadenius, T; Volyanskyy, D; Wissing, C; Zeuner, W D; Autermann, C; Bechtel, F; Draeger, J; Eckstein, D; Gebbert, U; Kaschube, K; Kaussen, G; Klanner, R; Mura, B; Naumann-Emme, S; Nowak, F; Pein, U; Sander, C; Schleper, P; Schum, T; Stadie, H; Steinbrück, G; Thomsen, J; Wolf, R; Bauer, J; Blüm, P; Buege, V; Cakir, A; Chwalek, T; De Boer, W; Dierlamm, A; Dirkes, G; Feindt, M; Felzmann, U; Frey, M; Furgeri, A; Gruschke, J; Hackstein, C; Hartmann, F; Heier, S; Heinrich, M; Held, H; Hirschbuehl, D; Hoffmann, K H; Honc, S; Jung, C; Kuhr, T; Liamsuwan, T; Martschei, D; Mueller, S; Müller, Th; Neuland, M B; Niegel, M; Oberst, O; Oehler, A; Ott, J; Peiffer, T; Piparo, D; Quast, G; Rabbertz, K; Ratnikov, F; Ratnikova, N; Renz, M; Saout, C; Sartisohn, G; Scheurer, A; Schieferdecker, P; Schilling, F P; Schott, G; Simonis, H J; Stober, F M; Sturm, P; Troendle, D; Trunov, A; Wagner, W; Wagner-Kuhr, J; Zeise, M; Zhukov, V; Ziebarth, E B; Daskalakis, G; Geralis, T; Karafasoulis, K; Kyriakis, A; Loukas, D; Markou, A; Markou, C; Mavrommatis, C; Petrakou, E; Zachariadou, A; Gouskos, L; Katsas, P; Panagiotou, A; Evangelou, I; Kokkas, P; Manthos, N; Papadopoulos, I; Patras, V; Triantis, F A; Bencze, G; Boldizsar, L; Debreczeni, G; Hajdu, C; Hernath, S; Hidas, P; Horvath, D; Krajczar, K; Laszlo, A; Patay, G; Sikler, F; Toth, N; Vesztergombi, G; Beni, N; Christian, G; Imrek, J; Molnar, J; Novak, D; Palinkas, J; Szekely, G; Szillasi, Z; Tokesi, K; Veszpremi, V; Kapusi, A; Marian, G; Raics, P; Szabo, Z; Trocsanyi, Z L; Ujvari, B; Zilizi, G; Bansal, S; Bawa, H S; Beri, S B; Bhatnagar, V; Jindal, M; Kaur, M; Kaur, R; Kohli, J M; Mehta, M Z; Nishu, N; Saini, L K; Sharma, A; Singh, A; Singh, J B; Singh, S P; Ahuja, S; Arora, S; Bhattacharya, S; Chauhan, S; Choudhary, B C; Gupta, P; Jain, S; Jha, M; Kumar, A; Ranjan, K; Shivpuri, R K; Srivastava, A K; Choudhury, R K; Dutta, D; Kailas, S; Kataria, S K; Mohanty, A K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Guchait, M; Gurtu, A; Maity, M; Majumder, D; Majumder, G; Mazumdar, K; Nayak, A; Saha, A; Sudhakar, K; Banerjee, S; Dugad, S; Mondal, N K; Arfaei, H; Bakhshiansohi, H; Fahim, A; Jafari, A; Mohammadi Najafabadi, M; Moshaii, A; Paktinat Mehdiabadi, S; Rouhani, S; Safarzadeh, B; Zeinali, M; Felcini, M; Abbrescia, M; Barbone, L; Chiumarulo, F; Clemente, A; Colaleo, A; Creanza, D; Cuscela, G; De Filippis, N; De Palma, M; De Robertis, G; Donvito, G; Fedele, F; Fiore, L; Franco, M; Iaselli, G; Lacalamita, N; Loddo, F; Lusito, L; Maggi, G; Maggi, M; Manna, N; Marangelli, B; My, S; Natali, S; Nuzzo, S; Papagni, G; Piccolomo, S; Pierro, G A; Pinto, C; Pompili, A; Pugliese, G; Rajan, R; Ranieri, A; Romano, F; Roselli, G; Selvaggi, G; Shinde, Y; Silvestris, L; Tupputi, S; Zito, G; Abbiendi, G; Bacchi, W; Benvenuti, A C; Boldini, M; Bonacorsi, D; Braibant-Giacomelli, S; Cafaro, V D; Caiazza, S S; Capiluppi, P; Castro, A; Cavallo, F R; Codispoti, G; Cuffiani, M; D'Antone, I; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Giordano, V; Giunta, M; Grandi, C; Guerzoni, M; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Odorici, F; Pellegrini, G; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G; Torromeo, G; Travaglini, R; Albergo, S; Costa, S; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Broccolo, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Frosali, S; Gallo, E; Genta, C; Landi, G; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Tropiano, A; Benussi, L; Bertani, M; Bianco, S; Colafranceschi, S; Colonna, D; Fabbri, F; Giardoni, M; Passamonti, L; Piccolo, D; Pierluigi, D; Ponzio, B; Russo, A; Fabbricatore, P; Musenich, R; Benaglia, A; Calloni, M; Cerati, G B; D'Angelo, P; De Guio, F; Farina, F M; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Martelli, A; Menasce, D; Miccio, V; Moroni, L; Negri, P; Paganoni, M; Pedrini, D; Pullia, A; Ragazzi, S; Redaelli, N; Sala, S; Salerno, R; Tabarelli de Fatis, T; Tancini, V; Taroni, S; Buontempo, S; Cavallo, N; Cimmino, A; De Gruttola, M; Fabozzi, F; Iorio, A O M; Lista, L; Lomidze, D; Noli, P; Paolucci, P; Sciacca, C; Azzi, P; Bacchetta, N; Barcellan, L; Bellan, P; Bellato, M; Benettoni, M; Biasotto, M; Bisello, D; Borsato, E; Branca, A; Carlin, R; Castellani, L; Checchia, P; Conti, E; Dal Corso, F; De Mattia, M; Dorigo, T; Dosselli, U; Fanzago, F; Gasparini, F; Gasparini, U; Giubilato, P; Gonella, F; Gresele, A; Gulmini, M; Kaminskiy, A; Lacaprara, S; Lazzizzera, I; Margoni, M; Maron, G; Mattiazzo, S; Mazzucato, M; Meneghelli, M; Meneguzzo, A T; Michelotto, M; Montecassiano, F; Nespolo, M; Passaseo, M; Pegoraro, M; Perrozzi, L; Pozzobon, N; Ronchese, P; Simonetto, F; Toniolo, N; Torassa, E; Tosi, M; Triossi, A; Vanini, S; Ventura, S; Zotto, P; Zumerle, G; Baesso, P; Berzano, U; Bricola, S; Necchi, M M; Pagano, D; Ratti, S P; Riccardi, C; Torre, P; Vicini, A; Vitulo, P; Viviani, C; Aisa, D; Aisa, S; Babucci, E; Biasini, M; Bilei, G M; Caponeri, B; Checcucci, B; Dinu, N; Fanò, L; Farnesini, L; Lariccia, P; Lucaroni, A; Mantovani, G; Nappi, A; Piluso, A; Postolache, V; Santocchia, A; Servoli, L; Tonoiu, D; Vedaee, A; Volpe, R; Azzurri, P; Bagliesi, G; Bernardini, J; Berretta, L; Boccali, T; Bocci, A; Borrello, L; Bosi, F; Calzolari, F; Castaldi, R; Dell'Orso, R; Fiori, F; Foà, L; Gennai, S; Giassi, A; Kraan, A; Ligabue, F; Lomtadze, T; Mariani, F; Martini, L; Massa, M; Messineo, A; Moggi, A; Palla, F; Palmonari, F; Petragnani, G; Petrucciani, G; Raffaelli, F; Sarkar, S; Segneri, G; Serban, A T; Spagnolo, P; Tenchini, R; Tolaini, S; Tonelli, G; Venturi, A; Verdini, P G; Baccaro, S; Barone, L; Bartoloni, A; Cavallari, F; Dafinei, I; Del Re, D; Di Marco, E; Diemoz, M; Franci, D; Longo, E; Organtini, G; Palma, A; Pandolfi, F; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Alampi, G; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Biino, C; Borgia, M A; Botta, C; Cartiglia, N; Castello, R; Cerminara, G; Costa, M; Dattola, D; Dellacasa, G; Demaria, N; Dughera, G; Dumitrache, F; Graziano, A; Mariotti, C; Marone, M; Maselli, S; Migliore, E; Mila, G; Monaco, V; Musich, M; Nervo, M; Obertino, M M; Oggero, S; Panero, R; Pastrone, N; Pelliccioni, M; Romero, A; Ruspa, M; Sacchi, R; Solano, A; Staiano, A; Trapani, P P; Trocino, D; Vilela Pereira, A; Visca, L; Zampieri, A; Ambroglini, F; Belforte, S; Cossutti, F; Della Ricca, G; Gobbo, B; Penzo, A; Chang, S; Chung, J; Kim, D H; Kim, G N; Kong, D J; Park, H; Son, D C; Bahk, S Y; Song, S; Jung, S Y; Hong, B; Kim, H; Kim, J H; Lee, K S; Moon, D H; Park, S K; Rhee, H B; Sim, K S; Kim, J; Choi, M; Hahn, G; Park, I C; Choi, S; Choi, Y; Goh, J; Jeong, H; Kim, T J; Lee, J; Lee, S; Janulis, M; Martisiute, D; Petrov, P; Sabonis, T; Castilla Valdez, H; Sánchez Hernández, A; Carrillo Moreno, S; Morelos Pineda, A; Allfrey, P; Gray, R N C; Krofcheck, D; Bernardino Rodrigues, N; Butler, P H; Signal, T; Williams, J C; Ahmad, M; Ahmed, I; Ahmed, W; Asghar, M I; Awan, M I M; Hoorani, H R; Hussain, I; Khan, W A; Khurshid, T; Muhammad, S; Qazi, S; Shahzad, H; Cwiok, M; Dabrowski, R; Dominik, W; Doroba, K; Konecki, M; Krolikowski, J; Pozniak, K; Romaniuk, Ryszard; Zabolotny, W; Zych, P; Frueboes, T; Gokieli, R; Goscilo, L; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Wrochna, G; Zalewski, P; Almeida, N; Antunes Pedro, L; Bargassa, P; David, A; Faccioli, P; Ferreira Parracho, P G; Freitas Ferreira, M; Gallinaro, M; Guerra Jordao, M; Martins, P; Mini, G; Musella, P; Pela, J; Raposo, L; Ribeiro, P Q; Sampaio, S; Seixas, J; Silva, J; Silva, P; Soares, D; Sousa, M; Varela, J; Wöhri, H K; Altsybeev, I; Belotelov, I; Bunin, P; Ershov, Y; Filozova, I; Finger, M; Finger, M., Jr.; Golunov, A; Golutvin, I; Gorbounov, N; Kalagin, V; Kamenev, A; Karjavin, V; Konoplyanikov, V; Korenkov, V; Kozlov, G; Kurenkov, A; Lanev, A; Makankin, A; Mitsyn, V V; Moisenz, P; Nikonov, E; Oleynik, D; Palichik, V; Perelygin, V; Petrosyan, A; Semenov, R; Shmatov, S; Smirnov, V; Smolin, D; Tikhonenko, E; Vasil'ev, S; Vishnevskiy, A; Volodko, A; Zarubin, A; Zhiltsov, V; Bondar, N; Chtchipounov, L; Denisov, A; Gavrikov, Y; Gavrilov, G; Golovtsov, V; Ivanov, Y; Kim, V; Kozlov, V; Levchenko, P; Obrant, G; Orishchin, E; Petrunin, A; Shcheglov, Y; Shchetkovskiy, A; Sknar, V; Smirnov, I; Sulimov, V; Tarakanov, V; Uvarov, L; Vavilov, S; Velichko, G; Volkov, S; Vorobyev, A; Andreev, Yu; Anisimov, A; Antipov, P; Dermenev, A; Gninenko, S; Golubev, N; Kirsanov, M; Krasnikov, N; Matveev, V; Pashenkov, A; Postoev, V E; Solovey, A; Toropin, A; Troitsky, S; Baud, A; Epshteyn, V; Gavrilov, V; Ilina, N; Kaftanov, V; Kolosov, V; Kossov, M; Krokhotin, A; Kuleshov, S; Oulianov, A; Safronov, G; Semenov, S; Shreyber, I; Stolin, V; Vlasov, E; Zhokin, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Petrushanko, S; Sarycheva, L; Savrin, V; Snigirev, A; Vardanyan, I; Dremin, I; Kirakosyan, M; Konovalova, N; Rusakov, S V; Vinogradov, A; Akimenko, S; Artamonov, A; Azhgirey, I; Bitioukov, S; Burtovoy, V; Grishin, V; Kachanov, V; Konstantinov, D; Krychkine, V; Levine, A; Lobov, I; Lukanin, V; Mel'nik, Y; Petrov, V; Ryutin, R; Slabospitsky, S; Sobol, A; Sytine, A; Tourtchanovitch, L; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Djordjevic, M; Jovanovic, D; Krpic, D; Maletic, D; Puzovic, J; Smiljkovic, N; Aguilar-Benitez, M; Alberdi, J; Alcaraz Maestre, J; Arce, P; Barcala, J M; Battilana, C; Burgos Lazaro, C; Caballero Bejar, J; Calvo, E; Cardenas Montes, M; Cepeda, M; Cerrada, M; Chamizo Llatas, M; Clemente, F; Colino, N; Daniel, M; De La Cruz, B; Delgado Peris, A; Diez Pardos, C; Fernandez Bedoya, C; Fernández Ramos, J P; Ferrando, A; Flix, J; Fouz, M C; Garcia-Abia, P; Garcia-Bonilla, A C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Marin, J; Merino, G; Molina, J; Molinero, A; Navarrete, J J; Oller, J C; Puerta Pelayo, J; Romero, L; Santaolalla, J; Villanueva Munoz, C; Willmott, C; Yuste, C; Albajar, C; Blanco Otano, M; de Trocóniz, J F; Garcia Raboso, A; Lopez Berengueres, J O; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Lloret Iglesias, L; Naves Sordo, H; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chuang, S H; Diaz Merino, I; Diez Gonzalez, C; Duarte Campderros, J; Fernandez, M; Gomez, G; Gonzalez Sanchez, J; Gonzalez Suarez, R; Jorda, C; Lobelle Pardo, P; Lopez Virto, A; Marco, J; Marco, R; Martinez Rivero, C; Martinez Ruiz del Arbol, P; Matorras, F; Rodrigo, T; Ruiz Jimeno, A; Scodellaro, L; Sobron Sanudo, M; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Albert, E; Alidra, M; Ashby, S; Auffray, E; Baechler, J; Baillon, P; Ball, A H; Bally, S L; Barney, D; Beaudette, F; Bellan, R; Benedetti, D; Benelli, G; Bernet, C; Bloch, P; Bolognesi, S; Bona, M; Bos, J; Bourgeois, N; Bourrel, T; Breuker, H; Bunkowski, K; Campi, D; Camporesi, T; Cano, E; Cattai, A; Chatelain, J P; Chauvey, M; Christiansen, T; Coarasa Perez, J A; Conde Garcia, A; Covarelli, R; Curé, B; De Roeck, A; Delachenal, V; Deyrail, D; Di Vincenzo, S; Dos Santos, S; Dupont, T; Edera, L M; Elliott-Peisert, A; Eppard, M; Favre, M; Frank, N; Funk, W; Gaddi, A; Gastal, M; Gateau, M; Gerwig, H; Gigi, D; Gill, K; Giordano, D; Girod, J P; Glege, F; Gomez-Reino Garrido, R; Goudard, R; Gowdy, S; Guida, R; Guiducci, L; Gutleber, J; Hansen, M; Hartl, C; Harvey, J; Hegner, B; Hoffmann, H F; Holzner, A; Honma, A; Huhtinen, M; Innocente, V; Janot, P; Le Godec, G; Lecoq, P; Leonidopoulos, C; Loos, R; Lourenço, C; Lyonnet, A; Macpherson, A; Magini, N; Maillefaud, J D; Maire, G; Mäki, T; Malgeri, L; Mannelli, M; Masetti, L; Meijers, F; Meridiani, P; Mersi, S; Meschi, E; Meynet Cordonnier, A; Moser, R; Mulders, M; Mulon, J; Noy, M; Oh, A; Olesen, G; Onnela, A; Orimoto, T; Orsini, L; Perez, E; Perinic, G; Pernot, J F; Petagna, P; Petiot, P; Petrilli, A; Pfeiffer, A; Pierini, M; Pimiä, M; Pintus, R; Pirollet, B; Postema, H; Racz, A; Ravat, S; Rew, S B; Rodrigues Antunes, J; Rolandi, G.; Rovere, M; Ryjov, V; Sakulin, H; Samyn, D; Sauce, H; Schäfer, C; Schlatter, W D; Schröder, M; Schwick, C; Sciaba, A; Segoni, I; Sharma, A; Siegrist, N; Siegrist, P; Sinanis, N; Sobrier, T; Sphicas, P; Spiga, D; Spiropulu, M; Stöckli, F; Traczyk, P; Tropea, P; Troska, J; Tsirou, A; Veillet, L; Veres, G I; Voutilainen, M; Wertelaers, P; Zanetti, M; Bertl, W; Deiters, K; Erdmann, W; Gabathuler, K; Horisberger, R; Ingram, Q; Kaestli, H C; König, S; Kotlinski, D; Langenegger, U; Meier, F; Renker, D; Rohe, T; Sibille, J; Starodumov, A; Betev, B; Caminada, L; Chen, Z; Cittolin, S; Da Silva Di Calafiori, D R; Dambach, S; Dissertori, G; Dittmar, M; Eggel, C; Eugster, J; Faber, G; Freudenreich, K; Grab, C; Hervé, A; Hintz, W; Lecomte, P; Luckey, P D; Lustermann, W; Marchica, C; Milenovic, P; Moortgat, F; Nardulli, A; Nessi-Tedaldi, F; Pape, L; Pauss, F; Punz, T; Rizzi, A; Ronga, F J; Sala, L; Sanchez, A K; Sawley, M C; Sordini, V; Stieger, B; Tauscher, L; Thea, A; Theofilatos, K; Treille, D; Trüb, P; Weber, M; Wehrli, L; Weng, J; Zelepoukine, S; Amsler, C; Chiochia, V; De Visscher, S; Regenfus, C; Robmann, P; Rommerskirchen, T; Schmidt, A; Tsirigkas, D; Wilke, L; Chang, Y H; Chen, E A; Chen, W T; Go, A; Kuo, C M; Li, S W; Lin, W; Bartalini, P; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y; Lei, Y J; Lin, S W; Lu, R S; Schümann, J; Shiu, J G; Tzeng, Y M; Ueno, K; Velikzhanin, Y; Wang, C C; Wang, M; Adiguzel, A; Ayhan, A; Azman Gokce, A; Bakirci, M N; Cerci, S; Dumanoglu, I; Eskut, E; Girgis, S; Gurpinar, E; Hos, I; Karaman, T; Kayis Topaksu, A; Kurt, P; Önengüt, G; Önengüt Gökbulut, G; Ozdemir, K; Ozturk, S; Polatöz, A; Sogut, K; Tali, B; Topakli, H; Uzun, D; Vergili, L N; Vergili, M; Akin, I V; Aliev, T; Bilmis, S; Deniz, M; Gamsizkan, H; Guler, A M; Öcalan, K; Serin, M; Sever, R; Surat, U E; Zeyrek, M; Deliomeroglu, M; Demir, D; Gülmez, E; Halu, A; Isildak, B; Kaya, M; Kaya, O; Ozkorucuklu, S; Sonmez, N; Levchuk, L; Lukyanenko, S; Soroka, D; Zub, S; Bostock, F; Brooke, J J; Cheng, T L; Cussans, D; Frazier, R; Goldstein, J; Grant, N; Hansen, M; Heath, G P; Heath, H F; Hill, C; Huckvale, B; Jackson, J; Mackay, C K; Metson, S; Newbold, D M; Nirunpong, K; Smith, V J; Velthuis, J; Walton, R; Bell, K W; Brew, C; Brown, R M; Camanzi, B; Cockerill, D J A; Coughlan, J A; Geddes, N I; Harder, K; Harper, S; Kennedy, B W; Murray, P; Shepherd-Themistocleous, C H; Tomalin, I R; Williams, J H; Womersley, W J; Worm, S D; Bainbridge, R; Ball, G; Ballin, J; Beuselinck, R; Buchmuller, O; Colling, D; Cripps, N; Davies, G; Della Negra, M; Foudas, C; Fulcher, J; Futyan, D; Hall, G; Hays, J; Iles, G; Karapostoli, G; MacEvoy, B C; Magnan, A M; Marrouche, J; Nash, J; Nikitenko, A; Papageorgiou, A; Pesaresi, M; Petridis, K; Pioppi, M; Raymond, D M; Rompotis, N; Rose, A; Ryan, M J; Seez, C; Sharp, P; Sidiropoulos, G; Stettler, M; Stoye, M; Takahashi, M; Tapper, A; Timlin, C; Tourneur, S; Vazquez Acosta, M; Virdee, T; Wakefield, S; Wardrope, D; Whyntie, T; Wingham, M; Cole, J E; Goitom, I; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Munro, C; Reid, I D; Siamitros, C; Taylor, R; Teodorescu, L; Yaselli, I; Bose, T; Carleton, M; Hazen, E; Heering, A H; Heister, A; John, J St; Lawson, P; Lazic, D; Osborne, D; Rohlf, J; Sulak, L; Wu, S; Andrea, J; Avetisyan, A; Bhattacharya, S; Chou, J P; Cutts, D; Esen, S; Kukartsev, G; Landsberg, G; Narain, M; Nguyen, D; Speer, T; Tsang, K V; Breedon, R; Calderon De La Barca Sanchez, M; Case, M; Cebra, D; Chertok, M; Conway, J; Cox, P T; Dolen, J; Erbacher, R; Friis, E; Ko, W; Kopecky, A; Lander, R; Lister, A; Liu, H; Maruyama, S; Miceli, T; Nikolic, M; Pellett, D; Robles, J; Searle, M; Smith, J; Squires, M; Stilley, J; Tripathi, M; Vasquez Sierra, R; Veelken, C; Andreev, V; Arisaka, K; Cline, D; Cousins, R; Erhan, S; Hauser, J; Ignatenko, M; Jarvis, C; Mumford, J; Plager, C; Rakness, G; Schlein, P; Tucker, J; Valuev, V; Wallny, R; Yang, X; Babb, J; Bose, M; Chandra, A; Clare, R; Ellison, J A; Gary, J W; Hanson, G; Jeng, G Y; Kao, S C; Liu, F; Liu, H; Luthra, A; Nguyen, H; Pasztor, G; Satpathy, A; Shen, B C; Stringer, R; Sturdy, J; Sytnik, V; Wilken, R; Wimpenny, S; Branson, J G; Dusinberre, E; Evans, D; Golf, F; Kelley, R; Lebourgeois, M; Letts, J; Lipeles, E; Mangano, B; Muelmenstaedt, J; Norman, M; Padhi, S; Petrucci, A; Pi, H; Pieri, M; Ranieri, R; Sani, M; Sharma, V; Simon, S; Würthwein, F; Yagil, A; Campagnari, C; D'Alfonso, M; Danielson, T; Garberson, J; Incandela, J; Justus, C; Kalavase, P; Koay, S A; Kovalskyi, D; Krutelyov, V; Lamb, J; Lowette, S; Pavlunin, V; Rebassoo, F; Ribnik, J; Richman, J; Rossin, R; Stuart, D; To, W; Vlimant, J R; Witherell, M; Apresyan, A; Bornheim, A; Bunn, J; Chiorboli, M; Gataullin, M; Kcira, D; Litvine, V; Ma, Y; Newman, H B; Rogan, C; Timciuc, V; Veverka, J; Wilkinson, R; Yang, Y; Zhang, L; Zhu, K; Zhu, R Y; Akgun, B; Carroll, R; Ferguson, T; Jang, D W; Jun, S Y; Paulini, M; Russ, J; Terentyev, N; Vogel, H; Vorobiev, I; Cumalat, J P; Dinardo, M E; Drell, B R; Ford, W T; Heyburn, B; Luiggi Lopez, E; Nauenberg, U; Stenson, K; Ulmer, K; Wagner, S R; Zang, S L; Agostino, L; Alexander, J; Blekman, F; Cassel, D; Chatterjee, A; Das, S; Gibbons, L K; Heltsley, B; Hopkins, W; Khukhunaishvili, A; Kreis, B; Kuznetsov, V; Patterson, J R; Puigh, D; Ryd, A; Shi, X; Stroiney, S; Sun, W; Teo, W D; Thom, J; Vaughan, J; Weng, Y; Wittich, P; Beetz, C P; Cirino, G; Sanzeni, C; Winn, D; Abdullin, S; Afaq, M A; Albrow, M; Ananthan, B; Apollinari, G; Atac, M; Badgett, W; Bagby, L; Bakken, J A; Baldin, B; Banerjee, S; Banicz, K; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Biery, K; Binkley, M; Bloch, I; Borcherding, F; Brett, A M; Burkett, K; Butler, J N; Chetluru, V; Cheung, H W K; Chlebana, F; Churin, I; Cihangir, S; Crawford, M; Dagenhart, W; Demarteau, M; Derylo, G; Dykstra, D; Eartly, D P; Elias, J E; Elvira, V D; Evans, D; Feng, L; Fischler, M; Fisk, I; Foulkes, S; Freeman, J; Gartung, P; Gottschalk, E; Grassi, T; Green, D; Guo, Y; Gutsche, O; Hahn, A; Hanlon, J; Harris, R M; Holzman, B; Howell, J; Hufnagel, D; James, E; Jensen, H; Johnson, M; Jones, C D; Joshi, U; Juska, E; Kaiser, J; Klima, B; Kossiakov, S; Kousouris, K; Kwan, S; Lei, C M; Limon, P; Lopez Perez, J A; Los, S; Lueking, L; Lukhanin, G; Lusin, S; Lykken, J; Maeshima, K; Marraffino, J M; Mason, D; McBride, P; Miao, T; Mishra, K; Moccia, S; Mommsen, R; Mrenna, S; Muhammad, A S; Newman-Holmes, C; Noeding, C; O'Dell, V; Prokofyev, O; Rivera, R; Rivetta, C H; Ronzhin, A; Rossman, P; Ryu, S; Sekhri, V; Sexton-Kennedy, E; Sfiligoi, I; Sharma, S; Shaw, T M; Shpakov, D; Skup, E; Smith, R P; Soha, A; Spalding, W J; Spiegel, L; Suzuki, I; Tan, P; Tanenbaum, W; Tkaczyk, S; Trentadue, R; Uplegger, L; Vaandering, E W; Vidal, R; Whitmore, J; Wicklund, E; Wu, W; Yarba, J; Yumiceva, F; Yun, J C; Acosta, D; Avery, P; Barashko, V; Bourilkov, D; Chen, M; Di Giovanni, G P; Dobur, D; Drozdetskiy, A; Field, R D; Fu, Y; Furic, I K; Gartner, J; Holmes, D; Kim, B; Klimenko, S; Konigsberg, J; Korytov, A; Kotov, K; Kropivnitskaya, A; Kypreos, T; Madorsky, A; Matchev, K; Mitselmakher, G; Pakhotin, Y; Piedra Gomez, J; Prescott, C; Rapsevicius, V; Remington, R; Schmitt, M; Scurlock, B; Wang, D; Yelton, J; Ceron, C; Gaultney, V; Kramer, L; Lebolo, L M; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Adams, T; Askew, A; Baer, H; Bertoldi, M; Chen, J; Dharmaratna, W G D; Gleyzer, S V; Haas, J; Hagopian, S; Hagopian, V; Jenkins, M; Johnson, K F; Prettner, E; Prosper, H; Sekmen, S; Baarmand, M M; Guragain, S; Hohlmann, M; Kalakhety, H; Mermerkaya, H; Ralich, R; Vodopiyanov, I; Abelev, B; Adams, M R; Anghel, I M; Apanasevich, L; Bazterra, V E; Betts, R R; Callner, J; Castro, M A; Cavanaugh, R; Dragoiu, C; Garcia-Solis, E J; Gerber, C E; Hofman, D J; Khalatian, S; Mironov, C; Shabalina, E; Smoron, A; Varelas, N; Akgun, U; Albayrak, E A; Ayan, A S; Bilki, B; Briggs, R; Cankocak, K; Chung, K; Clarida, W; Debbins, P; Duru, F; Ingram, F D; Lae, C K; McCliment, E; Merlo, J P; Mestvirishvili, A; Miller, M J; Moeller, A; Nachtman, J; Newsom, C R; Norbeck, E; Olson, J; Onel, Y; Ozok, F; Parsons, J; Schmidt, I; Sen, S; Wetzel, J; Yetkin, T; Yi, K; Barnett, B A; Blumenfeld, B; Bonato, A; Chien, C Y; Fehling, D; Giurgiu, G; Gritsan, A V; Guo, Z J; Maksimovic, P; Rappoccio, S; Swartz, M; Tran, N V; Zhang, Y; Baringer, P; Bean, A; Grachov, O; Murray, M; Radicci, V; Sanders, S; Wood, J S; Zhukova, V; Bandurin, D; Bolton, T; Kaadze, K; Liu, A; Maravin, Y; Onoprienko, D; Svintradze, I; Wan, Z; Gronberg, J; Hollar, J; Lange, D; Wright, D; Baden, D; Bard, R; Boutemeur, M; Eno, S C; Ferencek, D; Hadley, N J; Kellogg, R G; Kirn, M; Kunori, S; Rossato, K; Rumerio, P; Santanastasio, F; Skuja, A; Temple, J; Tonjes, M B; Tonwar, S C; Toole, T; Twedt, E; Alver, B; Bauer, G; Bendavid, J; Busza, W; Butz, E; Cali, I A; Chan, M; D'Enterria, D; Everaerts, P; Gomez Ceballos, G; Hahn, K A; Harris, P; Jaditz, S; Kim, Y; Klute, M; Lee, Y J; Li, W; Loizides, C; Ma, T; Miller, M; Nahn, S; Paus, C; Roland, C; Roland, G; Rudolph, M; Stephans, G; Sumorok, K; Sung, K; Vaurynovich, S; Wenger, E A; Wyslouch, B; Xie, S; Yilmaz, Y; Yoon, A S; Bailleux, D; Cooper, S I; Cushman, P; Dahmes, B; De Benedetti, A; Dolgopolov, A; Dudero, P R; Egeland, R; Franzoni, G; Haupt, J; Inyakin, A; Klapoetke, K; Kubota, Y; Mans, J; Mirman, N; Petyt, D; Rekovic, V; Rusack, R; Schroeder, M; Singovsky, A; Zhang, J; Cremaldi, L M; Godang, R; Kroeger, R; Perera, L; Rahmat, R; Sanders, D A; Sonnek, P; Summers, D; Bloom, K; Bockelman, B; Bose, S; Butt, J; Claes, D R; Dominguez, A; Eads, M; Keller, J; Kelly, T; Kravchenko, I; Lazo-Flores, J; Lundstedt, C; Malbouisson, H; Malik, S; Snow, G R; Baur, U; Iashvili, I; Kharchilava, A; Kumar, A; Smith, K; Strang, M; Alverson, G; Barberis, E; Boeriu, O; Eulisse, G; Govi, G; McCauley, T; Musienko, Y; Muzaffar, S; Osborne, I; Paul, T; Reucroft, S; Swain, J; Taylor, L; Tuura, L; Anastassov, A; Gobbi, B; Kubik, A; Ofierzynski, R A; Pozdnyakov, A; Schmitt, M; Stoynev, S; Velasco, M; Won, S; Antonelli, L; Berry, D; Hildreth, M; Jessop, C; Karmgard, D J; Kolberg, T; Lannon, K; Lynch, S; Marinelli, N; Morse, D M; Ruchti, R; Slaunwhite, J; Warchol, J; Wayne, M; Bylsma, B; Durkin, L S; Gilmore, J; Gu, J; Killewald, P; Ling, T Y; Williams, G; Adam, N; Berry, E; Elmer, P; Garmash, A; Gerbaudo, D; Halyo, V; Hunt, A; Jones, J; Laird, E; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Piroué, P; Stickland, D; Tully, C; Werner, J S; Wildish, T; Xie, Z; Zuranski, A; Acosta, J G; Bonnett Del Alamo, M; Huang, X T; Lopez, A; Mendez, H; Oliveros, S; Ramirez Vargas, J E; Santacruz, N; Zatzerklyany, A; Alagoz, E; Antillon, E; Barnes, V E; Bolla, G; Bortoletto, D; Everett, A; Garfinkel, A F; Gecse, Z; Gutay, L; Ippolito, N; Jones, M; Koybasi, O; Laasanen, A T; Leonardo, N; Liu, C; Maroussov, V; Merkel, P; Miller, D H; Neumeister, N; Sedov, A; Shipsey, I; Yoo, H D; Zheng, Y; Jindal, P; Parashar, N; Cuplov, V; Ecklund, K M; Geurts, F J M; Liu, J H; Maronde, D; Matveev, M; Padley, B P; Redjimi, R; Roberts, J; Sabbatini, L; Tumanov, A; Betchart, B; Bodek, A; Budd, H; Chung, Y S; de Barbaro, P; Demina, R; Flacher, H; Gotra, Y; Harel, A; Korjenevski, S; Miner, D C; Orbaker, D; Petrillo, G; Vishnevskiy, D; Zielinski, M; Bhatti, A; Demortier, L; Goulianos, K; Hatakeyama, K; Lungu, G; Mesropian, C; Yan, M; Atramentov, O; Bartz, E; Gershtein, Y; Halkiadakis, E; Hits, D; Lath, A; Rose, K; Schnetzer, S; Somalwar, S; Stone, R; Thomas, S; Watts, T L; Cerizza, G; Hollingsworth, M; Spanier, S; Yang, Z C; York, A; Asaadi, J; Aurisano, A; Eusebi, R; Golyash, A; Gurrola, A; Kamon, T; Nguyen, C N; Pivarski, J; Safonov, A; Sengupta, S; Toback, D; Weinberger, M; Akchurin, N; Berntzon, L; Gumus, K; Jeong, C; Kim, H; Lee, S W; Popescu, S; Roh, Y; Sill, A; Volobouev, I; Washington, E; Wigmans, R; Yazgan, E; Engh, D; Florez, C; Johns, W; Pathak, S; Sheldon, P; Andelin, D; Arenton, M W; Balazs, M; Boutle, S; Buehler, M; Conetti, S; Cox, B; Hirosky, R; Ledovskoy, A; Neu, C; Phillips II, D; Ronquest, M; Yohay, R; Gollapinni, S; Gunthoti, K; Harr, R; Karchin, P E; Mattson, M; Sakharov, A; Anderson, M; Bachtis, M; Bellinger, J N; Carlsmith, D; Crotty, I; Dasu, S; Dutta, S; Efron, J; Feyzi, F; Flood, K; Gray, L; Grogg, K S; Grothe, M; Hall-Wilton, R; Jaworski, M; Klabbers, P; Klukas, J; Lanaro, A; Lazaridis, C; Leonard, J; Loveless, R; Magrans de Abril, M; Mohapatra, A; Ott, G; Polese, G; Reeder, D; Savin, A; Smith, W H; Sourkov, A; Swanson, J; Weinberg, M; Wenman, D; Wensveen, M; White, A

    2010-01-01

    During autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.

  10. Measurement of gamma quantum interaction point in plastic scintillator with WLS strips

    Energy Technology Data Exchange (ETDEWEB)

    Smyrski, J., E-mail: smyrski@if.uj.edu.pl [Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, S. Łojasiewicza 11, 30-348 Cracow (Poland); Alfs, D.; Bednarski, T.; Białas, P.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gupta-Sharma, N. [Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, S. Łojasiewicza 11, 30-348 Cracow (Poland); Gorgol, M.; Jasińska, B. [Department of Nuclear Methods, Institute of Physics, Maria Curie-Sklodowska University, 20-031 Lublin (Poland); Kajetanowicz, M.; Kamińska, D.; Korcyl, G. [Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, S. Łojasiewicza 11, 30-348 Cracow (Poland); Kowalski, P. [Świerk Computing Centre, National Centre for Nuclear Research, 05-400 Otwock-Świerk (Poland); Krzemień, W. [High Energy Department, National Centre for Nuclear Research, 05-400 Otwock-Świerk (Poland); Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz. [Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, S. Łojasiewicza 11, 30-348 Cracow (Poland); and others

    2017-04-11

    The feasibility of measuring the aśxial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons escaping from the scintillator with an array of wavelength-shifting (WLS) strips is demonstrated. Using a test set-up comprising a BC-420 scintillator bar and an array of sixteen BC-482A WLS strips we achieved a spatial resolution of 5 mm (σ) for annihilation photons from a {sup 22}Na isotope. The studied method can be used to improve the spatial resolution of a plastic-scintillator-based PET scanner which is being developed by the J-PET collaboration.

  11. Multiple Electron Stripping of Heavy Ion Beams

    International Nuclear Information System (INIS)

    Mueller, D.; Grisham, L.; Kaganovich, I.; Watson, R. L.; Horvat, V.; Zaharakis, K. E.; Peng, Y.

    2002-01-01

    One approach being explored as a route to practical fusion energy uses heavy ion beams focused on an indirect drive target. Such beams will lose electrons while passing through background gas in the target chamber, and therefore it is necessary to assess the rate at which the charge state of the incident beam evolves on the way to the target. Accelerators designed primarily for nuclear physics or high energy physics experiments utilize ion sources that generate highly stripped ions in order to achieve high energies economically. As a result, accelerators capable of producing heavy ion beams of 10 to 40 Mev/amu with charge state 1 currently do not exist. Hence, the stripping cross-sections used to model the performance of heavy ion fusion driver beams have, up to now, been based upon theoretical calculations. We have investigated experimentally the stripping of 3.4 Mev/amu Kr 7+ and Xe +11 in N2; 10.2 MeV/amu Ar +6 in He, N2, Ar and Xe; 19 MeV/amu Ar +8 in He, N2, Ar and Xe; 30 MeV He 1 + in He, N2, Ar and Xe; and 38 MeV/amu N +6 in He, N2, Ar and Xe. The results of these measurements are compared with the theoretical calculations to assess their applicability over a wide range of parameters

  12. Deuteron stripping reactions with Tabakin potential

    International Nuclear Information System (INIS)

    Osman, A.

    1976-05-01

    Deuteron stripping reactions are considered. Due to the strong repulsion between nucleons at very short distances, we have investigated the nuclear short-range correlations. The neutron proton nuclear potential in the deuteron is taken as a short-range repulsive core surrounded by a long-range attractive potential. The neutron-proton potential is taken as the Tabakin separable potential to take into account the short-range correlations. The differential cross-sections for deuteron stripping reactions have been calculated in two different cases by taking Yamaguchi or Breit et al type parameters for the Tabakin potential used. The angular distributions for different (d,p) stripping reactions on the different target nuclei 28 Si, 32 , 34 S, 36 Ar, 40 , 48 Ca, 50 , 52 , 54 Cr have been calculated using the DWBA calculations. Our present theoretical calculations for the angular distributions of the different reactions cosidered have been fitted to the experimental data, where good agreement is obtained. The extracted spectroscopic factors from the present work are found to be more reliable

  13. The Argonne silicon strip-detector array

    Energy Technology Data Exchange (ETDEWEB)

    Wuosmaa, A H; Back, B B; Betts, R R; Freer, M; Gehring, J; Glagola, B G; Happ, Th; Henderson, D J; Wilt, P [Argonne National Lab., IL (United States); Bearden, I G [Purdue Univ., Lafayette, IN (United States). Dept. of Physics

    1992-08-01

    Many nuclear physics experiments require the ability to analyze events in which large numbers of charged particles are detected and identified simultaneously, with good resolution and high efficiency, either alone, or in coincidence with gamma rays. The authors have constructed a compact large-area detector array to measure these processes efficiently and with excellent energy resolution. The array consists of four double-sided silicon strip detectors, each 5x5 cm{sup 2} in area, with front and back sides divided into 16 strips. To exploit the capability of the device fully, a system to read each strip-detector segment has been designed and constructed, based around a custom-built multi-channel preamplifier. The remainder of the system consists of high-density CAMAC modules, including multi-channel discriminators, charge-sensing analog-to-digital converters, and time-to-digital converters. The array`s performance has been evaluated using alpha-particle sources, and in a number of experiments conducted at Argonne and elsewhere. Energy resolutions of {Delta}E {approx} 20-30 keV have been observed for 5 to 8 MeV alpha particles, as well as time resolutions {Delta}T {<=} 500 ps. 4 figs.

  14. CLOSED-LOOP STRIPPING ANALYSIS (CLSA) OF ...

    Science.gov (United States)

    Synthetic musk compounds have been found in surface water, fish tissues, and human breast milk. Current techniques for separating these compounds from fish tissues require tedious sample clean-upprocedures A simple method for the deterrnination of these compounds in fish tissues has been developed. Closed-loop stripping of saponified fish tissues in a I -L Wheaton purge-and-trap vessel is used to strip compounds with high vapor pressures such as synthetic musks from the matrix onto a solid sorbent (Abselut Nexus). This technique is useful for screening biological tissues that contain lipids for musk compounds. Analytes are desorbed from the sorbent trap sequentially with polar and nonpolar solvents, concentrated, and directly analyzed by high resolution gas chromatography coupled to a mass spectrometer operating in the selected ion monitoring mode. In this paper, we analyzed two homogenized samples of whole fish tissues with spiked synthetic musk compounds using closed-loop stripping analysis (CLSA) and pressurized liquid extraction (PLE). The analytes were not recovered quantitatively but the extraction yield was sufficiently reproducible for at least semi-quantitative purposes (screening). The method was less expensive to implement and required significantly less sample preparation than the PLE technique. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water,

  15. Effect of tooth whitening strips on fatigue resistance and flexural strength of bovine dentin in vitro.

    Directory of Open Access Journals (Sweden)

    Laura E Tam

    Full Text Available To determine the effects of whitening strips on bovine dentin fatigue resistance and flexural strength in vitro.A total of eighty bovine dentin specimens (2x2x17mm were treated with either: control glycerine gel on plastic film wrap or whitening strips containing 9.5% hydrogen peroxide. Treatment was applied for 30 minutes, twice a day, for 1- or 4-weeks. After the last treatment, ten specimens per group were randomly selected to undergo fatigue testing (106 cycles, 3Hz, 20N while the other ten were subjected to flexural strength testing after ten days of storage in artificial saliva. Kaplan-Meier method with a log rank test, Wilcoxon test and Cox regression were used to assess fatigue test results (p<0.05. One-way ANOVA and Tukey's tests were used to compare the flexural strength results (p<0.05.There were significant differences in survival during the fatigue test among the groups (p<0.001. Treatment (control or bleach was a significant factor for specimen survival (p<0.001, Exp(B = 33.45. There were significant differences in mean flexural strength (p<0.001. No significant difference was found between "1-wk control" and "4-wk control". The mean flexural strength and fatigue resistance of the "4-wk bleach" were significantly lower than all the other groups.The use of whitening strips reduced the fatigue resistance and flexural strength of bovine dentin in vitro. Until the effect of whitening strips on mechanical properties of human dentin is fully elucidated, it remains prudent to advise patients to avoid excessive direct use of whitening strips on dentin.

  16. Fabrication of wire and flat strips with elevated recrystallization temperature of Mo monocrystals

    International Nuclear Information System (INIS)

    Mikhajlov, S.M.; Nesgovorov, V.V.; Kabakova, L.G.; Korzukhin, V.E.; Savitskij, E.M.; Burkhanov, G.S.; Ottenberg, E.V.

    1977-01-01

    A technique is developed for manufacturing wire and flat strip of elevated recrystallization point from single crystals fo molybdenum with micro-additions of zirconium and titanium by rotary hot forging with subsequent drawing under hydrodynamic friction conditions. Flat strip is manufactured next from a wire annealed at 1300-1400 deg C in hydrogen. Resultant wire and flat strip feature a high recrystallization point and a good shape stability. Tests on their ultimate strength on the range of temperatures between 20 and 1700 deg C have shown that the maximum temperature of the recrystallization onset is that of a wire from Mo single crystals of orientation [110], containing micro-additions of Zr and Ti, whereas loss of strength is at its highest in a wire from non-alloyed single-crystal molybdenum

  17. Numerical and experimental study on multi-pass laser bending of AH36 steel strips

    Science.gov (United States)

    Fetene, Besufekad N.; Kumar, Vikash; Dixit, Uday S.; Echempati, Raghu

    2018-02-01

    Laser bending is a process of bending of plates, small sized sheets, strips and tubes, in which a moving or stationary laser beam heats the workpiece to achieve the desired curvature due to thermal stresses. Researchers studied the effects of different process parameters related to the laser source, material and workpiece geometry on laser bending of metal sheets. The studies are focused on large sized sheets. The workpiece geometry parameters like sheet thickness, length and width also affect the bend angle considerably. In this work, the effects of width and thickness on multi-pass laser bending of AH36 steel strips were studied experimentally and numerically. Finite element model using ABAQUS® was developed to investigate the size effect on the prediction of the bend angle. Microhardness and flexure tests showed an increase in the flexural strength as well as microhardness in the scanned zone. The microstructures of the bent strips also supported the physical observations.

  18. Characterization of constrained aged Ni Ti strips for using in artificial muscle actuators

    International Nuclear Information System (INIS)

    Hassanzadeh Nemati, N.; Sadrnezhaad, S. K.

    2011-01-01

    Marvelous bending/straightening effects of two-way shape memory alloy help their employment in design and manufacturing of new medical appliances. Constrained ageing with bending load scheme can induce two-way shape memory effect. Scanning electron microscopic analysis, electrical resistivity measurement and differential scanning calorimetry are employed to determine the property change due to flat strip constrained aging. Results show that flat-annealing prior to the aging shifts Ni Ti transformations temperatures to higher values. Super elastic behavior of the as-received/flat-annealed/aged samples with more adequate transition temperatures due to biological tissue replacement is studied by three-point flexural tests. Results show that curing changes the transition points of the Ni Ti strips. These changes affect the shape memory behavior of the Ni Ti strips embedded within the biocompatible flexible composite segments.

  19. Noise analysis due to strip resistance in the ATLAS SCT silicon strip module

    International Nuclear Information System (INIS)

    Kipnis, I.

    1996-08-01

    The module is made out of four 6 cm x 6 cm single sided Si microstrip detectors. Two detectors are butt glued to form a 12 cm long mechanical unit and strips of the two detectors are electrically connected to form 12 cm long strips. The butt gluing is followed by a back to back attachment. The module in this note is the Rφ module where the electronics is oriented parallel to the strip direction and bonded directly to the strips. This module concept provides the maximum signal-to-noise ratio, particularly when the front-end electronics is placed near the middle rather than at the end. From the noise analysis, it is concluded that the worst-case ΔENC (far-end injection) between end- and center-tapped modules will be 120 to 210 el. rms (9 to 15%) for a non-irradiated detector and 75 to 130 el. rms (5 to 9%) for an irradiated detector, for a metal strip resistance of 10 to 20 Ω/cm

  20. Influence for high intensity irradiation on characteristics of silicon strip-detectors

    International Nuclear Information System (INIS)

    Anokhin, I.E.; Pugatch, V.M.; Zinets, O.S.

    1995-01-01

    Full text: Silicon strip detectors (SSD) are widely used for the coordinate determination of short-range as well as minimum ionizing particles with high spatial resolution. Submicron position sensitivity of strip-detectors for short-range particles has been studied by means of two dimensional analyses of charges collected by neighboring strips as well as by measurement of charge collection times [1]. Silicon strip detectors was also used for testing high energy electron beam [2]. Under large fluences the radiation defects are stored and such characteristics of strip-detectors as an accuracy of the coordinate determination and the registration efficiency are significantly changed. Radiation defects lead to a decrease of the lifetime and mobility of charge carriers and therefore to changes of conditions for the charge collection in detectors. The inhomogeneity in spatial distribution if defects and electrical field plays an important role in the charge collection. In this report the role of the diffusion and drift in the charge collection in silicon strip-detectors under irradiation up to 10 Mrad has been studied. The electric field distribution and its dependence on the radiation dose in the detector have been calculated. It is shown that for particles incident between adjacent strips the coordinate determination precision depends strongly on the detector geometry and the electric field distribution, particularly in the vicinity of strips. Measuring simultaneously the collected charges and collection times on adjacent strips one can essentially improve reliability of the coordinate determination for short-range particles. Usually SSD are fabricated on n-type wafers. It is well known that under high intensity irradiation n-Si material converts into p-Si as far as p-type silicon is more radiative hard than n-type silicon [3] it is reasonable to fabricate SSD using high resistivity p-Si. Characteristics of SSD in basis n-and P-Si have been compared and higher

  1. Cross-talk studies on FPCB of double-sided silicon micro-strip detector

    International Nuclear Information System (INIS)

    Yang, Lei; Li, Zhankui; Li, Haixia; Wang, Pengfei; Wang, Zhusheng; Chen, Cuihong; Liu, Fengqiong; Li, Ronghua; Wang, Xiuhua; Li, Chunyan; Zu, Kailing

    2014-01-01

    Double-sided silicon micro-strip detector's parameters and a test method and the results of cross-talk of FPCB are given in this abstract. In addition, the value of our detector's readout signal has little relation to FPCB's cross-talk.

  2. Proposed method of assembly for the BCD silicon strip vertex detector modules

    International Nuclear Information System (INIS)

    Lindenmeyer, C.

    1989-01-01

    The BCD Silicon strip Vertex Detector is constructed of 10 identical central region modules and 18 similar forward region modules. This memo describes a method of assembling these modules from individual silicon wafers. Each wafer is fitted with associated front end electronics and cables and has been tested to insure that only good wafers reach the final assembly stage. 5 figs

  3. Can Whitening Strips interfere with the Bond Strength of Composite Resins?

    Science.gov (United States)

    Firoozmand, Leily Macedo; Reis, Washington Luís Machado dos; Vieira, Mercêdes Aroucha; Nunes, Adriana Gomes; Tavarez, Rudys Rodolfo de Jesus; Tonetto, Mateus Rodrigues; Bramante, Fausto Silva; Bhandi, Shilpa H; Roma, Regina Vieira de Oliveira; Bandeca, Matheus Coelho

    2015-04-01

    The aim of this study was to investigate in vitro the bond strength of composite resins on enamel previously treated with whitening strips. A total of 48 bovine incisors were allocated to four experimental groups (n = 12 each): G1 (WSC)- treated with 9.5% hydrogen peroxide whitening strips (3D White Whitestrips® Advanced Vivid/CREST); G2 (WSO)-treated with 10% hydrogen peroxide whitening strips (3D WhiteTM/Oral B); G3 (WG)-treated with 7.5% hydrogen peroxide gel with fluorine, calcium and potassium nitrate (White Class®/FGM); and G4 (C)-control not subjected to bleaching treatment. The specimens were subjected to bleaching over 2 weeks following the manufacturers' instructions. Following the elaboration of the composite resin test specimens, the samples were stored in artificial saliva and subsequently subjected to the micro-shear test using the universal testing machine (EMIC®). The bond strength values were analyzed by one-way ANOVA and Tukey's statistical test (5%). Significant differences were observed among the investigated groups (p enamel-resin interface. The bond strength decreased following 14 days of treatment with bleaching strips, whereas the whitening gel with 7.5% hydrogen peroxide, calcium and fluorine increased the bond strength.

  4. A low power bipolar amplifier integrated circuit for the ZEUS silicon strip system

    Energy Technology Data Exchange (ETDEWEB)

    Barberis, E. (Inst. for Particle Physics, Univ. of California, Santa Cruz, CA (United States)); Cartiglia, N. (Inst. for Particle Physics, Univ. of California, Santa Cruz, CA (United States)); Dorfan, D.E. (Inst. for Particle Physics, Univ. of California, Santa Cruz, CA (United States)); Spencer, E. (Inst. for Particle Physics, Univ. of California, Santa Cruz, CA (United States))

    1993-05-01

    A fast low power bipolar chip consisting of 64 amplifier-comparators has been developed for use with silicon strip detectors for systems where high radiation levels and high occupancy considerations are important. The design is described and test results are presented. (orig.)

  5. Validity and interobserver agreement of reagent strips for measurement of glucosuria

    NARCIS (Netherlands)

    Bekhof, Jolita; Kollen, Boudewijn J.; Groot-Jebbink, Liesbeth J. M.; Deiman, Corrie; Van de Leur, Sjef J. C. M.; Van Straaten, Henrica L. M.

    Background. Measurement of glucosuria by means of a visually readable reagent test strip is frequently used in a wide variety of clinical settings. The aim of this study was to evaluate the validity and reliability of this semi-quantitative measurement of glucosuria compared to laboratory

  6. Cold-rolled steel strip X-ray thickness gauge

    International Nuclear Information System (INIS)

    Tong Jianmin; Cong Peng; Li Litao

    2010-01-01

    This paper introduces a cold-rolled steel strip X-ray thickness gauge. This gauge uses two-detector construction including penetrating ionization chamber and measuring ionization chamber. Standard magazine box is composed of three rotating plates driving by stepper motor, including 13 pieces of standard sample to build up 154 thickness value, obtaining standard sample curve covering thickness range of 0.1 mm to 5 mm. Automation system include Siemens S7-200 PLC as key controlling unit, embedded controlling system for data acquisition and computing, and PC as man-machine interface, and employ Ethernet (TCP/IP) or RS485/232 as communication protocol. Reversing Cold mill AGC closed-loop control operation test demonstrates that the gauge can adapt to the severe production environment, operate stably and reliably, measurement precision can reached to ±0.19%, reproducibility to ±0.09%, and stability to ±0.06%, response time range from 4 ms to 200 ms and be adjustable. So it can meet the high demanding of cold-rolled plate/strip production. (authors)

  7. Gold recovery from organic solvents using galvanic stripping

    Energy Technology Data Exchange (ETDEWEB)

    Flores, C.; O`Keefe, T.J. [Univ. of Missouri, Rolla, MO (United States). Dept. of Metallurgical Engineering

    1995-08-01

    A novel process using solid metals for the direct reduction of more noble metal ions from solvent extraction organics has been developed. Base metals recovery has been the principal focus of investigations to date but feasibility tests have now also been made on galvanically stripping selected precious metals. In this study gold (III) was loaded from an aqueous HAuCl{sub 4}{center_dot}3H{sub 2}O solution into a mixed organic 40 vol.% TBP, 10 vol.% D2EHPA in kerosene. The direct precipitation of metallic gold from the loaded organic phase using zinc powder and iron, aluminum and copper slabs at 70 C was successfully demonstrated. The gold reduction rates were relatively fast even though the conductivity of the organic solutions is very low. The reaction rates were studied as a function of the variables zinc particulate size, oxygen and nitrogen atmosphere, water content in the organic phase, organic ratios and temperature. The gold morphology was usually powdery or dendritic in nature but continuous films were obtained in some instances. Activation energies were calculated and possible reaction mechanisms are discussed. In general, the results obtained were very promising and showed that gold can be successfully cemented from selected organic solvents by galvanic stripping using less noble solid metal reductants.

  8. 'I wanted to safeguard the baby': a qualitative study to understand the experiences of Option B+ for pregnant women and the potential implications for 'test-and-treat' in four sub-Saharan African settings.

    Science.gov (United States)

    McLean, Estelle; Renju, Jenny; Wamoyi, Joyce; Bukenya, Dominic; Ddaaki, William; Church, Kathryn; Zaba, Basia; Wringe, Alison

    2017-07-01

    To explore what influences on engagement with Option B+ in four sub-Saharan African settings. In-depth interviews were conducted in 2015, with 22 HIV-positive women who had been pregnant since Option B+ was available, and 15 healthcare workers (HCWs) involved in HIV service delivery. Participants were purposely selected from four health and demographic surveillance sites in Malawi, Tanzania and Uganda. A thematic content analysis was conducted to investigate what influenced engagement with Option B+. Feeling 'ready' was key to pregnant women accepting antiretroviral treatment (ART) on the same day as diagnosis at antenatal clinic; this was influenced by previous knowledge of HIV-positive status, interactions with HCWs and relationship with their partners. The desire to protect their unborn infant was the main issue that motivated women to initiate treatment, temporarily over-riding barriers to starting ART. Many HCWs recognised that pressurising women into starting ART may lead them to stop treatment following delivery. However, their own responsibility to protect the infant sometimes drove HCWs to use strong persuasive techniques to initiate pregnant women onto ART as early as possible, occasionally causing women to disengage. Protecting the baby superseded feelings of unpreparedness for lifelong ART and may explain poor retention observed in Option B+ programmes. Women may benefit from more time to accept their status, and counselling on the long-term value of ART beyond the pregnancy and breastfeeding period. Strategies to promote readiness for same-day initiation of lifelong treatment are urgently needed, and may provide important lessons for universal test-and-treat implementation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Modeling and optimization of operating parameters for a test-cell option of the Fusion Power Demonstration-II tandem mirror design

    International Nuclear Information System (INIS)

    Haney, S.W.; Fenstermacher, M.E.

    1985-01-01

    Models of tandem mirror devices operated with a test-cell insert have been used to calculate operating parameters for FPD-II+T, an upgrade of the Fusion Power Demonstration-II device. Two test-cell configurations were considered, one accommodating two 1.5 m blanket test modules and the other having four. To minimize the cost of the upgrade, FPD-II+T utilizes the same coil arrangement and machine dimensions outside of the test cell as FPD-II, and the requirements on the end cell systems have been held near or below those for FPD-II. The maximum achievable test cell wall loading found for the short test-cell was 3.5 MW/m 2 while 6.0 MW/m 2 was obtainable in the long test-cell configuration. The most severe limitation on the achievable wall loading is the upper limit on test-cell beta set by MHD stability calculations. Modification of the shape of the magnetic field in the test-cell by improving the magnet design could raise this beta limit and lead to improved test-cell performance

  10. Deformation behavior of curling strips on tearing tubes

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Won; Kwon, Tae Soo; Jung, Hyun Seung; Kim, Jin Sung [Dept. of Robotics and Virtual Engineering, Korea University of Science and Technology, Seoul (Korea, Republic of)

    2015-10-15

    This paper discusses the analysis of the curl deformation behavior when a dynamic force is applied to a tearing tube installed on a flat die to predict the energy absorption capacity and deformation behavior. The deformation of the tips of the curling strips was obtained when the curl tips and tube body are in contact with each other, and a formula describing the energy dissipation rate caused by the deformation of the curl tips is proposed. To improve this formula, we focused on the variation of the curl radius and the reduced thickness of the tube. A formula describing the mean curl radius is proposed and verified using the curl radius measurement data of collision test specimens. These improved formulas are added to the theoretical model previously proposed by Huang et al. and verified from the collision test results of a tearing tube.

  11. Ion-implanted capacitively coupled silicon strip detectors with integrated polysilicon bias resistors processed on a 100 mm wafer

    International Nuclear Information System (INIS)

    Hietanen, I.; Lindgren, J.; Orava, R.; Tuuva, T.; Voutilainen, M.; Brenner, R.; Andersson, M.; Leinonen, K.; Ronkainen, H.

    1991-01-01

    Double-sided silicon strip detectors with integrated coupling capacitors and polysilicon resistors have been processed on a 100 mm wafer. A detector with an active area of 19x19 mm 2 was connected to LSI readout electronics and tested. The strip pitch of the detector is 25 μm on the p-side and 50 μm on the n-side. The readout pitch is 50 μm on both sides. The number of readout strips is 774 and the total number of strips is 1161. On the p-side a signal-to-noise of 35 has been measured using a 90 Sr β-source. The n-side has been studied using a laser. (orig.)

  12. The origins of options.

    Science.gov (United States)

    Smaldino, Paul E; Richerson, Peter J

    2012-01-01

    Most research on decision making has focused on how human or animal decision makers choose between two or more options, posed in advance by the researchers. The mechanisms by which options are generated for most decisions, however, are not well understood. Models of sequential search have examined the trade-off between continued exploration and choosing one's current best option, but still cannot explain the processes by which new options are generated. We argue that understanding the origins of options is a crucial but untapped area for decision making research. We explore a number of factors which influence the generation of options, which fall broadly into two categories: psycho-biological and socio-cultural. The former category includes factors such as perceptual biases and associative memory networks. The latter category relies on the incredible human capacity for culture and social learning, which doubtless shape not only our choices but the options available for choice. Our intention is to start a discussion that brings us closer toward understanding the origins of options.

  13. Americal options analyzed differently

    NARCIS (Netherlands)

    Nieuwenhuis, J.W.

    2003-01-01

    In this note we analyze in a discrete-time context and with a finite outcome space American options starting with the idea that every tradable should be a martingale under a certain measure. We believe that in this way American options become more understandable to people with a good working

  14. Downstream process options for the ABE fermentation.

    Science.gov (United States)

    Friedl, Anton

    2016-05-01

    Butanol is a very interesting substance both for the chemical industry and as a biofuel. The classical distillation process for the removal of butanol is far too energy demanding, at a factor of 220% of the energy content of butanol. Alternative separation processes studied are hybrid processes of gas-stripping, liquid-liquid extraction and pervaporation with distillation and a novel adsorption/drying/desorption hybrid process. Compared with the energy content of butanol, the resulting energy demand for butanol separation and concentration of optimized hybrid processes is 11%-22% for pervaporation/distillation and 11%-17% for liquid-liquid extraction/distillation. For a novel adsorption/drying/desorption process, the energy demand is 9.4%. But all downstream process options need further proof of industrial applicability. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Paper Strip-based Fluorometric Determination of Cyanide with an Internal Reference

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Nam; Hong, Jong-In [Seoul National University, Seoul (Korea, Republic of); Seo, Hyejin; Shin, Ik-Soo [Soongsil University, Seoul (Korea, Republic of)

    2016-08-15

    The rapid, selective, and sensitive determination of cyanide anion (CN{sup -}) using a simple paper strip is highly attractive because cyanide is acutely lethal to living organisms via all routes of administration, including alcohol consumption and inhaling cigarette smoke. Here, a synthetic probe (1) was designed for the selective determination of cyanide. The probe displays rapid and large blue spectral change (Δλ{sub abs}=148 nm, Δλ{sub em}= 165 nm) with respect to target recognition. Probe 1 exhibits a strong push-pull electronic effect and comprises a dimethylaminoaryl group as a donor and malononitrile as an acceptor; the π-conjugation system can be destroyed by the Michael-type addition of cyanide at the electrophilic β-positions of the nitrile groups, resulting in the marked emergence of a peak at λ{sub em}= 515 nm. The developed probe was successfully applied to a paper test strip because of its noticeable optical changes upon reaction with cyanide. The fabricated dumbbell-shaped paper strip with an internal reference allowed the cyanide detection, which is indispensable for quantitative analysis in point-of-care testing. The paper strip test showed selective response to cyanide, with a linear correlation in the range of 0-25 mM in a simple and cost-effective manner.

  16. Paper Strip-based Fluorometric Determination of Cyanide with an Internal Reference

    International Nuclear Information System (INIS)

    Lee, Dong-Nam; Hong, Jong-In; Seo, Hyejin; Shin, Ik-Soo

    2016-01-01

    The rapid, selective, and sensitive determination of cyanide anion (CN"-) using a simple paper strip is highly attractive because cyanide is acutely lethal to living organisms via all routes of administration, including alcohol consumption and inhaling cigarette smoke. Here, a synthetic probe (1) was designed for the selective determination of cyanide. The probe displays rapid and large blue spectral change (Δλ_a_b_s=148 nm, Δλ_e_m= 165 nm) with respect to target recognition. Probe 1 exhibits a strong push-pull electronic effect and comprises a dimethylaminoaryl group as a donor and malononitrile as an acceptor; the π-conjugation system can be destroyed by the Michael-type addition of cyanide at the electrophilic β-positions of the nitrile groups, resulting in the marked emergence of a peak at λ_e_m= 515 nm. The developed probe was successfully applied to a paper test strip because of its noticeable optical changes upon reaction with cyanide. The fabricated dumbbell-shaped paper strip with an internal reference allowed the cyanide detection, which is indispensable for quantitative analysis in point-of-care testing. The paper strip test showed selective response to cyanide, with a linear correlation in the range of 0-25 mM in a simple and cost-effective manner.

  17. Traffic Light Options

    DEFF Research Database (Denmark)

    Jørgensen, Peter Løchte

    This paper introduces, prices, and analyzes traffic light options. The traffic light option is an innovative structured OTC derivative developed independently by several London-based investment banks to suit the needs of Danish life and pension (L&P) companies, which must comply with the traffic...... 2006, and supervisory authorities in many other European countries have implemented similar regulation. Traffic light options are therefore likely to attract the attention of a wider audience of pension fund managers in the future. Focusing on the valuation of the traffic light option we set up a Black...... light scenarios. These stress scenarios entail drops in interest rates as well as in stock prices, and traffic light options are thus designed to pay off and preserve sufficient capital when interest rates and stock prices fall simultaneously. Sweden's FSA implemented a traffic light system in January...

  18. Traffic Light Options

    DEFF Research Database (Denmark)

    Jørgensen, Peter Løchte

    2007-01-01

    This paper introduces, prices, and analyzes traffic light options. The traffic light option is an innovative structured OTC derivative developed independently by several London-based investment banks to suit the needs of Danish life and pension (L&P) companies, which must comply with the traffic...... 2006, and supervisory authorities in many other European countries have implemented similar regulation. Traffic light options are therefore likely to attract the attention of a wider audience of pension fund managers in the future. Focusing on the valuation of the traffic light option we set up a Black...... light scenarios. These stress scenarios entail drops in interest rates as well as in stock prices, and traffic light options are thus designed to pay off and preserve sufficient capital when interest rates and stock prices fall simultaneously. Sweden's FSA implemented a traffic light system in January...

  19. A digital X-ray imaging system based on silicon strip detectors working in edge-on configuration

    Energy Technology Data Exchange (ETDEWEB)

    Bolanos, L. [CEADEN, Calle 30 502 e/ 5ta y 7ma Avenida, Playa, Ciudad Habana (Cuba); Boscardin, M. [IRST, Fondazione Bruno Kessler, Via Sommarive 18, Povo, 38100 Trento (Italy); Cabal, A.E. [CEADEN, Calle 30 502 e/ 5ta y 7ma Avenida, Playa, Ciudad Habana (Cuba); Diaz, M. [InSTEC, Ave. Salvador Allende esq. Luaces, Quinta de los Molinos, Ciudad Habana (Cuba); Grybos, P.; Maj, P. [Faculty of Electrical Engineering, Automatics, Computer Science and Electronics, Department of Measurement and Instrumentation, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Prino, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Torino, Via P. Giuria 1, 10125 Torino (Italy); Ramello, L. [Dipartimento di Scienze e Tecnologie Avanzate, Universita del Piemonte Orientale, Via T. Michel 11, 15100 Alessandria (Italy)], E-mail: luciano.ramello@mfn.unipmn.it; Szczygiel, R. [Faculty of Electrical Engineering, Automatics, Computer Science and Electronics, Department of Measurement and Instrumentation, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland)

    2009-09-21

    We present the energy resolution and imaging performance of a digital X-ray imaging system based on a 512-strip silicon strip detector (SSD) working in the edge-on configuration. The SSDs tested in the system are 300 {mu}m thick with 1 or 2-cm-long strips and 100 {mu}m pitch. To ensure a very small dead area of the SSD working in edge-on configuration, the detector is cut perpendicular to the strips at a distance of only 20 {mu}m from the end of the strips. The 512-strip silicon detector is read out by eight 64-channel integrated circuits called DEDIX [Grybos et al., IEEE Trans. Nucl. Sci. NS-54 (2007) 1207]. The DEDIX IC operates in a single photon counting mode with two independent amplitude discriminators per channel. The readout electronic channel connected to a detector with effective input capacitance of about 2 pF has an average equivalent noise charge (ENC) of about 163 el. rms and is able to count 1 Mcps of average rate of input pulses. The system consisting of 512 channels has an excellent channel-to-channel uniformity-the effective threshold spread calculated to the charge-sensitive amplifier inputs is 12 el. rms (at one sigma level). With this system a few test images of a phantom have been taken in the 10-30 keV energy range.

  20. Pre-clinical test of the virtual wedge option of a PRIMUS linear accelerator and verification of the calculation algorithm in the treatment planning system HEAX-TMS

    International Nuclear Information System (INIS)

    Gesheva-Atanassova, N.; Balabanova, A.

    2006-01-01

    Full text: The purpose of the study is to check the long-time stability of the wedge angle and the wedge factor (WF) of Virtual Wedges for 6 and 18 MV photon beams, and the accuracy of the TPS HELAX-TMS, in order to accept the virtual wedge technique for patient treatment. All measurements - dose profiles, central axis dose distributions and applied dose for pre-calculated monitor units, have been performed in water, applying a calibrated 0.3 cm 3 ion chamber, 47 ion chamber array LA48 and the beam analyzing system MP3. The measured data has been compared with the corresponding planned data. During a four years time period the long time stability checking revealed no changes in the central axis distributions and variations of the wedge angles are within ± 2 deg. The values of WFs and the differences between calculated and measured dose values are in the acceptable limits, except for the 6 MV beam with wedge angle 60 deg and field size 20x20 cm 2 , where the deviation reaches 6.5%. The dose profile for depth up to 10 cm showed a good coincidence. Non acceptable deviations have been found for beam profiles at depth 20 cm and field size 20x20 cm 2 for both 6 and 18 MV. The Virtual Wedge Option of PRIMUS in combination with HELAX-TMS can be applied with confidence for radiotherapy with wedged beams except for the combination of field 20x20 cm 2 and angle 60 deg

  1. Development of a colloidal gold immunochromatographic strip for rapid detection of Streptococcus agalactiae in tilapia.

    Science.gov (United States)

    Wen-de, Wu; Min, Li; Ming, Chen; Li-Ping, Li; Rui, Wang; Hai-Lan, Chen; Fu-Yan, Chen; Qiang, Mi; Wan-Wen, Liang; Han-Zhong, Chen

    2017-05-15

    A colloidal gold immunochromatographic strip was developed for rapid detection of Streptococcus agalactiae (S. agalactiae) infection in tilapia. The monoclonal antibodies (mAb) 4C12 and 3A9 were used to target S. agalactiae as colloidal gold-mAb conjugate and captured antibody, respectively. The colloidal gold immunochromatographic strip was assembled via routine procedures. Optimal pH and minimum antibody levels in the reaction system for gold colloidal-mAb 4C12 conjugation were pH 7.4 and 18μg/mL, respectively. Optimal concentrations of the captured antibody 3A9 and goat anti-mouse antibody were 0.6mg/mL and 2mg/mL, respectively. The sensitivity of the strip for detecting S. agalactiae was 1.5×10 5 colony forming units (CFU). No cross-reaction was observed with other commonly encountered bacteria, including Pseudomonas fluorescens, Aeromonas hydrophila, Vibrio anguillarum and Streptococcus iniae. The assay time for S. agalactiae was less than 15min. Tilapia samples artificially infected with S. agalactiae were tested using the newly developed strip. The results indicated that blood, brain, kidney, spleen, metanephros and intestine specimens of infected fish can be used for S. agalactiae detection. The validity of the strip was maintained for 6 months at 4°C. These findings suggested that the immunochromatographic strip was effective for spot and rapid detection of S. agalactiae infected tilapia. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Polish Toxic Currency Options

    Directory of Open Access Journals (Sweden)

    Waldemar Gontarski

    2009-06-01

    Full Text Available Toxic currency options are defined on the basis of the opposition to the nature (essence of an option contract, which is justified in terms of norms founded on the general law clause of characteristics (nature of a relation (which represents an independent premise for imposing restrictions on the freedom of contracts. So-understood toxic currency options are unlawful. Indeed they contravene iuris cogentis regulations. These include for instance option contracts, which are concluded with a bank, if the bank has not informed about option risk before concluding the contract; or the barrier options, which focus only on the protection of bank’s interests. Therefore, such options may appear to be invalid. Therefore, performing contracts for toxic currency options may be qualified as a criminal mismanagement. For the sake of security, the manager should then take into consideration filing a claim for stating invalidity (which can be made in a court verdict. At the same time, if the supervisory board member in a commercial company, who can also be a subject to mismanagement offences, commits an omission involving lack of reaction (for example, if he/she fails to notify of the suspected offence committed by the management board members acting to the company’s detriment when the management board makes the company conclude option contracts which are charged with absolute invalidity the supervisory board member so acting may be considered to act to the company’s detriment. In the most recent Polish jurisprudence and judicature the standard of a “good host” is treated to be the last resort for determining whether the manager’s powers resulting from criminal regulations were performed. The manager of the exporter should not, as a rule, issue any options. Issuing options always means assuming an obligation. In the case of currency put options it is an absolute obligation to purchase a given amount in euro at exchange rate set in advance. On the

  3. High pressure water jet cutting and stripping

    Science.gov (United States)

    Hoppe, David T.; Babai, Majid K.

    1991-01-01

    High pressure water cutting techniques have a wide range of applications to the American space effort. Hydroblasting techniques are commonly used during the refurbishment of the reusable solid rocket motors. The process can be controlled to strip a thermal protective ablator without incurring any damage to the painted surface underneath by using a variation of possible parameters. Hydroblasting is a technique which is easily automated. Automation removes personnel from the hostile environment of the high pressure water. Computer controlled robots can perform the same task in a fraction of the time that would be required by manual operation.

  4. Nonlinear optical model for strip plasmonic waveguides

    DEFF Research Database (Denmark)

    Lysenko, Oleg; Bache, Morten; Lavrinenko, Andrei

    2016-01-01

    This paper presents a theoretical model of nonlinear optical properties for strip plasmonic waveguides. The particular waveguides geometry that we investigate contains a gold core, adhesion layers, and silicon dioxide cladding. It is shown that the third-order susceptibility of the gold core...... significantly depends on the layer thickness and has the dominant contribution to the effective third-order susceptibility of the long-range plasmon polariton mode. This results in two nonlinear optical effects in plasmonic waveguides, which we experimentally observed and reported in [Opt. Lett. 41, 317 (2016...... approaches. (C) 2016 Optical Society of America...

  5. Energy Fuels Nuclear, Inc. Arizona Strip Operations

    International Nuclear Information System (INIS)

    Pool, T.C.

    1993-01-01

    Founded in 1975 by uranium pioneer, Robert W. Adams, Energy Fuels Nuclear, Inc. (EFNI) emerged as the largest US uranium mining company by the mid-1980s. Confronting the challenges of declining uranium market prices and the development of high-grade ore bodies in Australia and Canada, EFNI aggressively pursued exploration and development of breccia-pipe ore bodies in Northwestern Arizona. As a result, EFNI's production for the Arizona Strip of 18.9 million pounds U 3 O 8 over the period 1980 through 1991, maintained the company's status as a leading US uranium producer

  6. 2005 resource options report

    International Nuclear Information System (INIS)

    Morris, T.

    2005-01-01

    This resource options report (ROR) fulfils regulatory requirements in British Columbia's two-year resource planning process. It identifies a wide range of resources and technologies that could be used to meet BC Hydro's future electricity demand. As such, it facilitates a transparent public review of resource options which include both supply-side and demand-side options. The resource options that will be used in the 2005 integrated electricity plan (IEP) were characterized. This ROR also documents where there is a general agreement or disagreement on the resource type characterization, based on the First Nations and Stakeholder engagement. BC Hydro used current information to provide realistic ranges on volume and cost to characterize environmental and social attributes. The BC Hydro system was modelled to assess the benefit and cost of various resource options. The information resulting from this ROR and IEP will help in making decisions on how to structure competitive acquisition calls and to determine the level of transmission services needed to advance certain BC Hydro projects. The IEP forecasts the nature and quantity of domestic resources required over the next 20 years. A strategic direction on how those needs will be met has been created to guide the management of BC Hydro's energy resources. Supply-side options include near-commercial technologies such as energy storage, ocean waves, tidal, fuel cells and integrated coal gasification combined cycle technology. Supply-side options also include natural gas, coal, biomass, geothermal, wind, and hydro. 120 refs., 39 tabs., 21 figs., 6 appendices

  7. Expensing options solves nothing.

    Science.gov (United States)

    Sahlman, William A

    2002-12-01

    The use of stock options for executive compensation has become a lightning rod for public anger, and it's easy to see why. Many top executives grew hugely rich on the back of the gains they made on their options, profits they've been able to keep even as the value they were supposed to create disappeared. The supposed scam works like this: Current accounting regulations let companies ignore the cost of option grants on their income statements, so they can award valuable option packages without affecting reported earnings. Not charging the cost of the grants supposedly leads to overstated earnings, which purportedly translate into unrealistically high share prices, permitting top executives to realize big gains when they exercise their options. If an accounting anomaly is the problem, then the solution seems obvious: Write off executive share options against the current year's revenues. The trouble is, Sahlman writes, expensing option grants won't give us a more accurate view of earnings, won't add any information not already included in the financial statements, and won't even lead to equal treatment of different forms of executive pay. Far worse, expensing evades the real issue, which is whether compensation (options and other-wise) does what it's supposed to do--namely, help a company recruit, retain, and provide the right people with appropriate performance incentives. Any performance-based compensation system has the potential to encourage cheating. Only ethical management, sensible governance, adequate internal control systems, and comprehensive disclosure will save the investor from disaster. If, Sahlman warns, we pass laws that require the expensing of options, thinking that's fixed the fundamental flaws in corporate America's accounting, we will have missed a golden opportunity to focus on the much more extensive defects in the present system.

  8. Early Option Exercise

    DEFF Research Database (Denmark)

    Heje Pedersen, Lasse; Jensen, Mads Vestergaard

    A classic result by Merton (1973) is that, except just before expiration or dividend payments, one should never exercise a call option and never convert a convertible bond. We show theoretically that this result is overturned when investors face frictions. Early option exercise can be optimal when...... it reduces short-sale costs, transaction costs, or funding costs. We provide consistent empirical evidence, documenting billions of dollars of early exercise for options and convertible bonds using unique data on actual exercise decisions and frictions. Our model can explain as much as 98% of early exercises...

  9. Early Option Exercise

    DEFF Research Database (Denmark)

    Jensen, Mads Vestergaard; Heje Pedersen, Lasse

    2016-01-01

    A classic result by Merton (1973) is that, except just before expiration or dividend payments, one should never exercise a call option and never convert a convertible bond. We show theoretically that this result is overturned when investors face frictions. Early option exercise can be optimal when...... it reduces short-sale costs, transaction costs, or funding costs. We provide consistent empirical evidence, documenting billions of dollars of early exercise for options and convertible bonds using unique data on actual exercise decisions and frictions. Our model can explain as much as 98% of early exercises...

  10. Study of fast operating readout electronics and charge interpolation technique for micro cathode strip chambers (MCSC)

    CERN Document Server

    Kashchuk, A; Sagidova, Nailia

    1998-01-01

    Study of the factors limiting the spatial resolution of the MCSC caused by nonlinearity of the cathode-charge interpolation technique has been carried out using a special test arrangement that imitates the charge distribution on the cathode strips as a real MCSC and allows high precision comparison of the coordinates determined by the charge interpolation technique with the known values. We considered a MCSC with a 0.6 mm gap between the anode and the cathode strip planes and with the strip pitch of 0.9 mm. Various charge interpolation algorithms have been tested. It was demonstrated that the systematics errors in the coordinate measurements as low as 5 microns can be achieved, after applying some simple corrections, even with rather coarse sampling, when the coordinates is determined only by 2 or 3 adjacent strips. These results have been obtained with the readout electronics specially designed for fast operation of the MCSCs with the signal peaking time of 20 ns. The equivalent noise charge ss 1600e (r.m.s....

  11. You're a good structure, Charlie Brown: the distribution of narrative categories in comic strips.

    Science.gov (United States)

    Cohn, Neil

    2014-01-01

    Cohn's (2013) theory of "Visual Narrative Grammar" argues that sequential images take on categorical roles in a narrative structure, which organizes them into hierarchic constituents analogous to the organization of syntactic categories in sentences. This theory proposes that narrative categories, like syntactic categories, can be identified through diagnostic tests that reveal tendencies for their distribution throughout a sequence. This paper describes four experiments testing these diagnostics to provide support for the validity of these narrative categories. In Experiment 1, participants reconstructed unordered panels of a comic strip into an order that makes sense. Experiment 2 measured viewing times to panels in sequences where the order of panels was reversed. In Experiment 3, participants again reconstructed strips but also deleted a panel from the sequence. Finally, in Experiment 4 participants identified where a panel had been deleted from a comic strip and rated that strip's coherence. Overall, categories had consistent distributional tendencies within experiments and complementary tendencies across experiments. These results point toward an interaction between categorical roles and a global narrative structure. © 2014 Cognitive Science Society, Inc.

  12. A test for measuring gustatory function.

    Science.gov (United States)

    Smutzer, Gregory; Lam, Si; Hastings, Lloyd; Desai, Hetvi; Abarintos, Ray A; Sobel, Marc; Sayed, Nabil

    2008-08-01

    The purpose of this study was to determine the usefulness of edible taste strips for measuring human gustatory function. The physical properties of edible taste strips were examined to determine their potential for delivering threshold and suprathreshold amounts of taste stimuli to the oral cavity. Taste strips were then assayed by fluorescence to analyze the uniformity and distribution of bitter tastant in the strips. Finally, taste recognition thresholds for sweet taste were examined to determine whether or not taste strips could detect recognition thresholds that were equal to or better than those obtained from aqueous tests. Edible strips were prepared from pullulan-hydroxypropyl methylcellulose solutions that were dried to a thin film. The maximal amount of a tastant that could be incorporated in a 2.54 cm2 taste strip was identified by including representative taste stimuli for each class of tastant (sweet, sour, salty, bitter, and umami) during strip formation. Distribution of the bitter tastant quinine hydrochloride in taste strips was assayed by fluorescence emission spectroscopy. The efficacy of taste strips for evaluating human gustatory function was examined by using a single series ascending method of limits protocol. Sucrose taste recognition threshold data from edible strips was then compared with results that were obtained from a standard "sip and spit" recognition threshold test. Edible films that formed from a pullulan-hydroxypropyl methylcellulose polymer mixture can be used to prepare clear, thin strips that have essentially no background taste and leave no physical presence after release of tastant. Edible taste strips could uniformly incorporate up to 5% of their composition as tastant. Taste recognition thresholds for sweet taste were over one order of magnitude lower with edible taste strips when compared with an aqueous taste test. Edible taste strips are a highly sensitive method for examining taste recognition thresholds in humans. This

  13. Apparatus for measuring profile thickness of strip material

    International Nuclear Information System (INIS)

    Hold, A.C.

    1982-01-01

    Apparatus for measuring the thickness profile of steel strip comprises a radiation source reciprocally movable in a stepwise fashion (by a belt) across the strip width on one side thereof and a single elongated detector on the other side of the strip aligned with the scanning source. This detector may be a fluorescent scintillator detector or an ionisation chamber. Means are provided for sensing the degree of excitation in the detector in synchronism with the scanning source whereby to provide an output representative of the thickness profile of the strip. (author)

  14. Stability of barotropic vortex strip on a rotating sphere

    Science.gov (United States)

    Sohn, Sung-Ik; Sakajo, Takashi; Kim, Sun-Chul

    2018-02-01

    We study the stability of a barotropic vortex strip on a rotating sphere, as a simple model of jet streams. The flow is approximated by a piecewise-continuous vorticity distribution by zonal bands of uniform vorticity. The linear stability analysis shows that the vortex strip becomes stable as the strip widens or the rotation speed increases. When the vorticity constants in the upper and the lower regions of the vortex strip have the same positive value, the inner flow region of the vortex strip becomes the most unstable. However, when the upper and the lower vorticity constants in the polar regions have different signs, a complex pattern of instability is found, depending on the wavenumber of perturbations, and interestingly, a boundary far away from the vortex strip can be unstable. We also compute the nonlinear evolution of the vortex strip on the rotating sphere and compare with the linear stability analysis. When the width of the vortex strip is small, we observe a good agreement in the growth rate of perturbation at an early time, and the eigenvector corresponding to the unstable eigenvalue coincides with the most unstable part of the flow. We demonstrate that a large structure of rolling-up vortex cores appears in the vortex strip after a long-time evolution. Furthermore, the geophysical relevance of the model to jet streams of Jupiter, Saturn and Earth is examined.

  15. Strip type radiation detector and method of making same

    International Nuclear Information System (INIS)

    Jantsch, O.; Feigt, I.; Willig, W.R.

    1976-01-01

    An improved strip detector and a method for making such a detector in which a high resistivity N conduction semiconductor body has electrode strips formed thereon by diffusion is described. The strips are formed so as to be covered by an oxide layer at the surface point of the PN junction and in which the opposite side of the semiconductor body then has a substantial amount of material etched away to form a thin semiconductor upon which strip electrodes which are perpendicular to the electrodes on the first side are then placed

  16. Stability of barotropic vortex strip on a rotating sphere.

    Science.gov (United States)

    Sohn, Sung-Ik; Sakajo, Takashi; Kim, Sun-Chul

    2018-02-01

    We study the stability of a barotropic vortex strip on a rotating sphere, as a simple model of jet streams. The flow is approximated by a piecewise-continuous vorticity distribution by zonal bands of uniform vorticity. The linear stability analysis shows that the vortex strip becomes stable as the strip widens or the rotation speed increases. When the vorticity constants in the upper and the lower regions of the vortex strip have the same positive value, the inner flow region of the vortex strip becomes the most unstable. However, when the upper and the lower vorticity constants in the polar regions have different signs, a complex pattern of instability is found, depending on the wavenumber of perturbations, and interestingly, a boundary far away from the vortex strip can be unstable. We also compute the nonlinear evolution of the vortex strip on the rotating sphere and compare with the linear stability analysis. When the width of the vortex strip is small, we observe a good agreement in the growth rate of perturbation at an early time, and the eigenvector corresponding to the unstable eigenvalue coincides with the most unstable part of the flow. We demonstrate that a large structure of rolling-up vortex cores appears in the vortex strip after a long-time evolution. Furthermore, the geophysical relevance of the model to jet streams of Jupiter, Saturn and Earth is examined.

  17. Carbon dioxide stripping in aquaculture -- part III: model verification

    Science.gov (United States)

    Colt, John; Watten, Barnaby; Pfeiffer, Tim

    2012-01-01

    Based on conventional mass transfer models developed for oxygen, the use of the non-linear ASCE method, 2-point method, and one parameter linear-regression method were evaluated for carbon dioxide stripping data. For values of KLaCO2 < approximately 1.5/h, the 2-point or ASCE method are a good fit to experimental data, but the fit breaks down at higher values of KLaCO2. How to correct KLaCO2 for gas phase enrichment remains to be determined. The one-parameter linear regression model was used to vary the C*CO2 over the test, but it did not result in a better fit to the experimental data when compared to the ASCE or fixed C*CO2 assumptions.

  18. Performance of irradiated CVD diamond micro-strip sensors

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S.V.; Thomson, G.B.

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15 /cm 2 ) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2x10 15 p/cm 2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9x10 15 π/cm 2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations

  19. Performance of irradiated CVD diamond micro-strip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D. E-mail: dirk.meier@cern.ch; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S.V.; Thomson, G.B

    2002-01-11

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a {beta}-source and the performance before and after intense (>10{sup 15}/cm{sup 2}) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2x10{sup 15} p/cm{sup 2} lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9x10{sup 15} {pi}/cm{sup 2} lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  20. Performance of irradiated CVD diamond micro-strip sensors

    CERN Document Server

    Adam, W; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Koeth, T W; Krammer, Manfred; Lo Giudice, A; Lü, R; MacLynne, L; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Noomen, J; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Perera, L P; Pirollo, S; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S R; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Wetstein, M; White, C; Zeuner, W; Zöller, M

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a $\\beta$-source and the performance before and after intense ($>10^{15}/{\\rm cm^2}$) proton- and pion-irradiations. We find that low dose irradiations increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiations with protons ($2.2\\times 10^{15}~p/{\\rm cm^2}$) lowers the signal-to-noise ratio slightly. Intense irradiation with pions ($2.9\\times 10^{15}~\\pi/{\\rm cm^2}$) lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  1. Performance of irradiated CVD diamond micro-strip sensors

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S. V.; Thomson, G. B.

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15/cm 2) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2×10 15 p/ cm2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9×10 15 π/ cm2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  2. A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisition.

    Science.gov (United States)

    Kim, H; Chen, C-T; Eclov, N; Ronzhin, A; Murat, P; Ramberg, E; Los, S; Wyrwicz, Alice M; Li, Limin; Kao, C-M

    2015-06-01

    We are developing a time-of-flight Positron Emission Tomography (PET) detector by using silicon photo-multipliers (SiPM) on a strip-line and high speed waveform sampling data acquisition. In this design, multiple SiPMs are connected on a single strip-line and signal waveforms on the strip-line are sampled at two ends of the strip to reduce readout channels while fully exploiting the fast time response of SiPMs. In addition to the deposited energy and time information, the position of the hit SiPM along the strip-line is determined by the arrival time difference of the waveform. Due to the insensitivity of the SiPMs to magnetic fields and the compact front-end electronics, the detector approach is highly attractive for developing a PET insert system for a magnetic resonance imaging (MRI) scanner to provide simultaneous PET/MR imaging. To investigate the feasibility, experimental tests using prototype detector modules have been conducted inside a 9.4 Tesla small animal MRI scanner (Bruker BioSpec 94/30 imaging spectrometer). On the prototype strip-line board, 16 SiPMs (5.2 mm pitch) are installed on two strip-lines and coupled to 2 × 8 LYSO scintillators (5.0 × 5.0 × 10.0 mm 3 with 5.2 mm pitch). The outputs of the strip-line boards are connected to a Domino-Ring-Sampler (DRS4) evaluation board for waveform sampling. Preliminary experimental results show that the effect of interference on the MRI image due to the PET detector is negligible and that PET detector performance is comparable with the results measured outside the MRI scanner.

  3. Getting More Power from Your Flowers: Multi-Functional Flower Strips Enhance Pollinators and Pest Control Agents in Apple Orchards.

    Science.gov (United States)

    Campbell, Alistair John; Wilby, Andrew; Sutton, Peter; Wäckers, Felix

    2017-09-20

    Flower strips are commonly recommended to boost biodiversity and multiple ecosystem services (e.g., pollination and pest control) on farmland. However, significant knowledge gaps remain regards the extent to which they deliver on these aims. Here, we tested the efficacy of flower strips that targeted different subsets of beneficial arthropods (pollinators and natural enemies) and their ecosystem services in cider apple orchards. Treatments included mixes that specifically targeted: (1) pollinators ('concealed-nectar plants'); (2) natural enemies ('open-nectar plants'); or (3) both groups concurrently (i.e., 'multi-functional' mix). Flower strips were established in alleyways of four orchards and compared to control alleyways (no flowers). Pollinator (e.g., bees) and natural enemy (e.g., parasitoid wasps, predatory flies and beetles) visitation to flower strips, alongside measures of pest control (aphid colony densities, sentinel prey predation), and fruit production, were monitored in orchards over two consecutive growing seasons. Targeted flower strips attracted either pollinators or natural enemies, whereas mixed flower strips attracted both groups in similar abundance to targeted mixes. Natural enemy densities on apple trees were higher in plots containing open-nectar plants compared to other treatments, but effects were stronger for non-aphidophagous taxa. Predation of sentinel prey was enhanced in all flowering plots compared to controls but pest aphid densities and fruit yield were unaffected by flower strips. We conclude that 'multi-functional' flower strips that contain flowering plant species with opposing floral traits can provide nectar and pollen for both pollinators and natural enemies, but further work is required to understand their potential for improving pest control services and yield in cider apple orchards.

  4. Monitoring the CMS strip tracker readout system

    International Nuclear Information System (INIS)

    Mersi, S; Bainbridge, R; Cripps, N; Fulcher, J; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Mirabito, L; Cole, J; Giassi, A; Gross, L; Hahn, K; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m 2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system

  5. Microwave assisted synthesis of hydroxyapatite nano strips

    Energy Technology Data Exchange (ETDEWEB)

    Ruban Kumar, A.; Kalainathan, S.; Saral, A.M. [School of Advanced Sciences, VIT University, Vellore 632014, Tamil Nadu (India)

    2010-07-15

    Synthesis of hydroxyapatite (HAP) nano strips was carried out by chemical precipitation method followed by microwave irradiation. The microwave assisted reactions proceed at fast rates. It is found that the presence of the complex reagent EDTA plays an important role in the morphological changes of nanostructure hydroxyapatite. EDTA acts as a hexadentate unit by wrapping itself around the Ca{sup 2+} metal ion with, four oxygen and two nitrogen atoms and forms several five member chelate rings. The relative specific surface energies associated with the facets of the crystal determines the shape of the crystal. Scanning electron microscopy revealed the presence of hydroxyapatite nano strips with the range 50-100 nm in EDTA influenced HAP powders. Fourier transform-infrared spectroscopy (FT-IR) result combined with the X-ray diffraction (XRD) indicates the presence of amorphous hydroxyapatite (HAP) in the as-prepared material. X-ray patterns collected on the powder after heat-treatment at 1100 C for 2 h in air exhibits single phase of HAP. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. The structure of the Cepheid instability strip

    International Nuclear Information System (INIS)

    Fernie, J.D.

    1990-01-01

    About 100 classical Cepheids having color excesses on a homogeneous system with standard errors of 0.02 or less mag are used with the Feast-Walker period-luminosity-color relation to study the distribution of such stars in the instability strip. It is found that mean (B-V)mag is a better indicator of mean effective temperature than is mean B(i) - mean V(i)(i). The blue edge of the color-magnitude distribution is consistent with the theoretical blue edge for Y = 0.28 and Z = 0.02. Although the highest amplitude stars are found near the center of the period-color array, high- and low-amplitude stars can intermingle, and both kinds are to be found near the edges of the distribution. The same is true on the C-M array. Finally, it is pointed out that the Cepheids do not populate the instability strip uniformly if the red edge is taken to be parallel to the theoretical blue edge. Rather, the local instability region runs as a parallelogram in the C-M array from the theoretical blue edge upward and to the red. 24 refs

  7. Thermometers: Understand the Options

    Science.gov (United States)

    ... the options Thermometers come in a variety of styles. Understand the different types of thermometers and how ... MA. Fever in infants and children: Pathophysiology and management. http://www.uptodate.com/home. Accessed July 23, ...

  8. Performance of the Scintillator-Strip Electromagnetic Calorimeter Prototype for the Linear Collider Experiment

    International Nuclear Information System (INIS)

    Uozumi, Satoru

    2011-01-01

    The scintillator-strip electromagnetic calorimeter (ScECAL) is one of fine granular calorimeters proposed to realize Particle Flow Algorithm for the International Linear Collider experiment. The ScECAL is a sandwitch calorimeter with tungsten and scintillator layers, where the scintillator layer consists of plastic scintillator strips which size of 1 cm x 4.5 cm x 0.2 cm with a small photo-sensor (MPPC) attached at the its edge. In alternate scintillator layers, strips are orthogonally aligned to make a virtual 1x 1 cm 2 cell with its crossing area. To establish the ScECAL technology, we have built a prototype of the ScECAL which consists of 30 layers of tungsten and scintillator layers with 2160 scintillator strips in total. In 2008 and 2009 the beam test has been performed at Fermilab meson test beam line to evaluate performance of the ScECAL prototype with various types of beams ranging 1 to 32 GeV. As a preliminary result of the beam test in 2008, we have obtained linearity of energy measurement less than 6% from the perfect linear response. Energy resolution is measured to be σ/E(15.15±0.03)%/√E+(1.44±0.02)%. Although detailed analyses are still ongoing, those results already establishes feasibility of the ScECAL as the fine granular calorimeter. However as the next step to precisely measure even higher energy jets, we will proceed to even more finely segmented calorimeter with 5 mm width scintillator strips.

  9. Options for human intrusion

    International Nuclear Information System (INIS)

    Bauser, M.; Williams, R.

    1993-01-01

    This paper addresses options for dealing with human intrusion in terms of performance requirements and repository siting and design requirements. Options are presented, along with the advantages and disadvantages of certain approaches. At the conclusion, a conceptual approach is offered emphasizing both the minimization of subjective judgements concerning future human activity, and specification of repository requirements to minimize the likelihood of human intrusion and any resulting, harmful effects should intrusion occur

  10. Evaluation of silicon micro strip detectors with large read-out pitch

    International Nuclear Information System (INIS)

    Senyo, K.; Yamamura, K.; Tsuboyama, T.; Avrillon, S.; Asano, Y.; Bozek, A.; Natkaniec, Z.; Palka, H.; Rozanska, M.; Rybicki, K.

    1996-01-01

    For the development of the silicon micro-strip detector with the pitch of the readout strips as large as 250 μm on the ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips. (orig.)

  11. Nevada Transportation Options Study

    International Nuclear Information System (INIS)

    P. GEHNER; E.M. WEAVER; L. FOSSUM

    2006-01-01

    This study performs a cost and schedule analysis of three Nevada Transportation options that support waste receipt at the repository. Based on the U.S. Department of Energy preference for rail transportation in Nevada (given in the Final Environmental Impact Statement), it has been assumed that a branch rail line would be constructed to support waste receipt at the repository. However, due to potential funding constraints, it is uncertain when rail will be available. The three Nevada Transportation options have been developed to meet a varying degree of requirements for transportation and to provide cost variations used in meeting the funding constraints given in the Technical Direction Letter guidelines for this study. The options include combinations of legal-weight truck, heavy-haul truck, and rail. Option 1 uses a branch rail line that would support initial waste receipt at the repository in 2010. Rail transportation would be the primary mode, supplemented by legal weight trucks. This option provides the highest level of confidence in cost and schedule, lowest public visibility, greatest public acceptability, lowest public dose, and is the recommended option for support of waste receipt. The completion of rail by 2010 will require spending approximately $800 million prior to 2010. Option 2 uses a phased rail approach to address a constrained funding scenario. To meet funding constraints, Option 2 uses a phased approach to delay high cost activities (final design and construction) until after initial waste receipt in 2010. By doing this, approximately 95 percent of the cost associated with completion of a branch rail line is deferred until after 2010. To support waste receipt until a branch rail line is constructed in Nevada, additional legal-weight truck shipments and heavy-haul truck shipments (on a limited basis for naval spent nuclear fuel) would be used to meet the same initial waste receipt rates as in Option 1. Use of heavy-haul shipments in the absence

  12. Options Study - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    R. Wigeland; T. Taiwo; M. Todosow; W. Halsey; J. Gehin

    2010-09-01

    The Options Study has been conducted for the purpose of evaluating the potential of alternative integrated nuclear fuel cycle options to favorably address the issues associated with a continuing or expanding use of nuclear power in the United States. The study produced information that can be used to inform decisions identifying potential directions for research and development on such fuel cycle options. An integrated nuclear fuel cycle option is defined in this study as including all aspects of the entire nuclear fuel cycle, from obtaining natural resources for fuel to the ultimate disposal of used nuclear fuel (UNF) or radioactive wastes. Issues such as nuclear waste management, especially the increasing inventory of used nuclear fuel, the current uncertainty about used fuel disposal, and the risk of nuclear weapons proliferation have contributed to the reluctance to expand the use of nuclear power, even though it is recognized that nuclear power is a safe and reliable method of producing electricity. In this Options Study, current, evolutionary, and revolutionary nuclear energy options were all considered, including the use of uranium and thorium, and both once-through and recycle approaches. Available information has been collected and reviewed in order to evaluate the ability of an option to clearly address the challenges associated with the current implementation and potential expansion of commercial nuclear power in the United States. This Options Study is a comprehensive consideration and review of fuel cycle and technology options, including those for disposal, and is not constrained by any limitations that may be imposed by economics, technical maturity, past policy, or speculated future conditions. This Phase II report is intended to be used in conjunction with the Phase I report, and much information in that report is not repeated here, although some information has been updated to reflect recent developments. The focus in this Options Study was to

  13. Systematic characterization and quality assurance of silicon micro-strip sensors for the Silicon Tracking System of the CBM experiment

    Science.gov (United States)

    Ghosh, P.

    2014-07-01

    The Silicon Tracking System (STS) is the central detector of the Compressed Baryonic Matter (CBM) experiment at future Facility for Anti-proton and Ion Research (FAIR) at Darmstadt. The task of the STS is to reconstruct trajectories of charged particles originating at relatively high multiplicities from the high rate beam-target interactions. The tracker comprises of 300 μm thick silicon double-sided micro-strip sensors. These sensors should be radiation hard in order to reconstruct charged particles up to a maximum radiation dose of 1 × 1014neqcm-2. Systematic characterization allows us to investigate the sensor response and perform quality assurance (QA) tests. In this paper, systematic characterization of prototype double-sided silicon micro-strip sensors will be discussed. This procedure includes visual, passive electrical, and radiation hardness test. Presented results include tests on three different prototypes of silicon micro-strip sensors.

  14. Systematic characterization and quality assurance of silicon micro-strip sensors for the Silicon Tracking System of the CBM experiment

    International Nuclear Information System (INIS)

    Ghosh, P

    2014-01-01

    The Silicon Tracking System (STS) is the central detector of the Compressed Baryonic Matter (CBM) experiment at future Facility for Anti-proton and Ion Research (FAIR) at Darmstadt. The task of the STS is to reconstruct trajectories of charged particles originating at relatively high multiplicities from the high rate beam-target interactions. The tracker comprises of 300 μm thick silicon double-sided micro-strip sensors. These sensors should be radiation hard in order to reconstruct charged particles up to a maximum radiation dose of 1 × 10 14 n eq cm −2 . Systematic characterization allows us to investigate the sensor response and perform quality assurance (QA) tests. In this paper, systematic characterization of prototype double-sided silicon micro-strip sensors will be discussed. This procedure includes visual, passive electrical, and radiation hardness test. Presented results include tests on three different prototypes of silicon micro-strip sensors

  15. Treatment Options for Wilms Tumor

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... come back) after it has been treated. Treatment Option Overview Key Points There are different types of ...

  16. Treatment Options for Myelodysplastic Syndromes

    Science.gov (United States)

    ... special light. Certain factors affect prognosis and treatment options. The prognosis (chance of recovery) and treatment options ... age and general health of the patient. Treatment Option Overview Key Points There are different types of ...

  17. Treatment Option Overview (Prostate Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  18. Treatment Option Overview (Myelodysplastic Syndromes)

    Science.gov (United States)

    ... special light. Certain factors affect prognosis and treatment options. The prognosis (chance of recovery) and treatment options ... age and general health of the patient. Treatment Option Overview Key Points There are different types of ...

  19. Treatment Option Overview (Esophageal Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  20. Treatment Option Overview (Childhood Rhabdomyosarcoma)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  1. Treatment Option Overview (Penile Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  2. Treatment Option Overview (Vulvar Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  3. Treatment Option Overview (Pancreatic Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  4. Treatment Option Overview (Adrenocortical Carcinoma)

    Science.gov (United States)

    ... affect the prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  5. Treatment Options for Childhood Rhabdomyosarcoma

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  6. Treatment Options for Kaposi Sarcoma

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  7. Treatment Options for Childhood Craniopharyngioma

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... the brain where it was first found. Treatment Option Overview Key Points There are different types of ...

  8. The challenge of a ban on animal testing for the development of a regulated legal market for new psychoactive substances (NPS) ('legal highs') in New Zealand: Issues and options for resolution.

    Science.gov (United States)

    Rychert, Marta; Wilkins, Chris

    2015-12-01

    In mid-July 2013, New Zealand passed the Psychoactive Substances Act (PSA), which allowed 'low risk' psychoactive products ('legal highs') to be approved for legal sale. In early May 2014, following public protest, the Psychoactive Substances Amendment Act (PSAA) was passed banning animal testing of psychoactive products, potentially making the new regime unworkable. To investigate strategies to overcome the impasse created by the animal testing ban. Solutions to the impasse were investigated using 'scenario' and 'stakeholder' analysis. Legislation, parliamentary debates, and regulatory statements related to the PSA and animal testing were reviewed. Strategies to resolve the impasse were discussed with stakeholders including the Psychoactive Substances Regulatory Authority (PSRA) officials, health officials, a legal high industry lawyer, and a leading legal highs manufacturer. This process generated six possible scenarios and five decision-making criteria of key importance to major stakeholders. Scenarios were then evaluated based on feedback from the industry and regulators. The six scenarios were: (1) pragmatic modification of the animal testing ban; (2) waiting until new non-animal test models are internationally accepted; (3) use of non-validated replacement test methods; (4) judicial challenge of the animal testing ban; (5) 'creative compliance' by only presenting human clinical trial results; and (6) philosophical re-conceptualisation of the 'benefits' from psychoactive products. Options 1 and 5 appear to be the most attractive overall solutions. However, both rely on a new political consensus and astute framing of the issues by political communicators. Political decision makers may be happy to accept Scenario 2 which would impose significant delays. A 'failed' pharmaceutical product with psychoactive effects may have the test data required to be approved under Scenarios 1 and 5. Ultimately, the pleasurable benefits from psychoactive products may need to be

  9. Development of colloidal gold immunochromatographic strips for detection of Riemerella anatipestifer.

    Directory of Open Access Journals (Sweden)

    Wanwan Hou

    Full Text Available Riemerella anatipestifer is one of the most important bacterial pathogen of ducks and causes a contagious septicemia. R. anatipestifer infection causes serositis syndromes similar to other bacterial infections in ducks, including infection by Escherichia coli, Salmonella enterica and Pasteurella multocida. Clinically differentiating R. anatipestifer infections from other bacterial pathogen infections is usually difficult. In this study, MAb 1G2F10, a monoclonal antibody against R. anatipestifer GroEL, was used to develop a colloidal gold immunochromatographic strip. Colloidal gold particles were prepared by chemical synthesis to an average diameter of 20 ± 5.26 nm by transmission electron microscope imaging. MAb 1G2F10 was conjugated to colloidal gold particles and the formation of antibody-colloidal gold conjugates was monitored by UV/Vis spectroscopy. Immunochromatographic strips were assembled in regular sequence through different accessories sticked on PVC plate. Strips specifically detected R. anatipestifer within 10 min, but did not detect E. coli, S. enterica and P. multocida. The detection limit for R. anatipestifer was 1 × 10(6 colony forming units, which was 500 times higher than a conventional agglutination test. Accuracy was 100% match to multiplex PCR. Assay stability and reproducibility were excellent after storage at 4°C for 6 months. The immunochromatographic strips prepared in this study offer a specific, sensitive, and rapid detection method for R. anatipestifer, which is of great importance for the prevention and control of R. anatipestifer infections.

  10. [Comparative measurement of urine specific gravity: reagent strips, refractometry and hydrometry].

    Science.gov (United States)

    Costa, Christian Elías; Bettendorff, Carolina; Bupo, Sol; Ayuso, Sandra; Vallejo, Graciela

    2010-06-01

    The urine specific gravity is commonly used in clinical practice to measure the renal concentration/dilution ability. Measurement can be performed by three methods: hydrometry, refractometry and reagent strips. To assess the accuracy of different methods to measure urine specific gravity. We analyzed 156 consecutive urine samples of pediatric patients during April and May 2007. Urine specific gravity was measured by hydrometry (UD), refractometry (RE) and reagent strips (TR), simultaneously. Urine osmolarity was considered as the gold standard and was measured by freezing point depression. Correlation between different methods was calculated by simple linear regression. A positive and acceptable correlation was found with osmolarity for the RE as for the UD (r= 0.81 and r= 0.86, respectively). The reagent strips presented low correlation (r= 0.46). Also, we found good correlation between measurements obtained by UD and RE (r= 0.89). Measurements obtained by TR, however, had bad correlation when compared to UD (r= 0.46). Higher values of specific gravity were observed when measured with RE with respect to UD. Reagent strips are not reliable for measuring urine specific gravity and should not be used as an usual test. However, hydrometry and refractometry are acceptable alternatives for measuring urine specific gravity, as long as the same method is used for follow-up.

  11. Development of a colloidal gold immunochromatographic strip based on HSP70 for the rapid detection of Echinococcus granulosus in sheep.

    Science.gov (United States)

    Zhuo, Xunhui; Yu, Yingchao; Chen, Xueqiu; Zhang, Zhuangzhi; Yang, Yi; Du, Aifang

    2017-06-15

    Echinococcus granulosus is the causative pathogen of cystic echinococcosis, a serious disease endangering human and animal health. In this study, an immunochromatographic strip was developed based on the recombinant protein Heat shock protein 70 (HSP70) for the serological detection of E. granulosus. The protocol completes within 20min requiring no specialized equipment or chemical reagents, while specificity tests confirmed no cross-reactivity with positive serum of Fasciola hepatica, Haemonchus contortus, Peste des petits ruminants virus (PPRV) and Foot-and-mouth disease virus (FMDV). The strips remained stable after storage at 4°C for up to 8 months. Both immunochromatographic strip and ELISA tests were applied to detect E. granulosus antibody in a total of 728 serum samples obtained from slaughter houses in Zhejiang Province. Our data revealed positive rates of 2.61 and 1.65% by immunochromatographic strip and ELISA methods, respectively. The immunochromatographic strip test developed in this study provides a simple, specific and rapid method of E. granulosus antibody detection and infected sheep monitoring. Copyright © 2017. Published by Elsevier B.V.

  12. Development of stripper options for FRIB

    Energy Technology Data Exchange (ETDEWEB)

    Marti, F.; Hershcovitch, A.; Momozaki, Y.; Nolen, J.; Reed, C.; Thieberger, P.

    2010-09-12

    The US Department of Energy Facility for Rare Isotope Beams (FRIB) at Michigan State University includes a heavy ion superconducting linac capable of accelerating all ions up to uranium with energies higher than 200 MeV/u and beam power up to 400 kW. To achieve these goals with present ion source performance it is necessary to accelerate simultaneously two charge states of uranium from the ion source in the first section of the linac. At an energy of approximately 16.5 MeV/u it is planned to strip the uranium beam to reduce the voltage needed in the rest of the linac to achieve the final energy. Up to five different charge states are planned to be accelerated simultaneously after the stripper. The design of the stripper is a challenging problem due to the high power deposited (approximately 0.7 kW) in the stripper media by the beam in a small spot. To assure success of the project we have established a research and development program that includes several options: carbon or diamond foils, liquid lithium films, gas strippers and plasma strippers. We present in this paper the status of the different options.

  13. Do repeated rumble strip hits improve driver alertness?

    NARC