WorldWideScience

Sample records for test stand consisting

  1. A high voltage test stand for electron gun qualification for LINACs

    International Nuclear Information System (INIS)

    Wanmode, Yashwant D.; Mulchandani, J.; Acharya, M.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam

    2011-01-01

    An electron gun lest stand has been developed at RRCAT. The test stand consists of a high voltage pulsed power supply, electron gun filament supply, grid supply, UHV system and electron gun current measurement system. Several electron guns developed indigenously were evaluated on this test stand. The shielding is provided for the electron gun set up. Electron gun tests can be tested upto 55 kV with pulse width of 15 microsecs and pulse repetition rates up to 200 Hz. The technical details of the subsystems are furnished and results of performance of the test stand have been reported in this paper. (author)

  2. Multi-Purpose Test Stand

    Data.gov (United States)

    Federal Laboratory Consortium — The Multi-Purpose Test Stand is used for a wide variety of tests. The Stand is designed to be rotated through a range of fixed yaw positions to allow engines to be...

  3. The Stimulus test stand

    International Nuclear Information System (INIS)

    Christofek, L.; Rapidis, P.; Reinhard, A.; Fermilab

    2005-01-01

    The Stimulus Test Stand was originally constructed and assembled for testing the SVX2 ASIC readout and then upgraded for SVX3 ASIC prototyping and testing. We have modified this system for SVX4 ASIC [1] prototype testing. We described the individual components below. Additional details for other hardware for SVX4 testing can be found in reference [2]. We provide a description of the Stimulus Test Stand used for prototype testing of the SVX4 chip

  4. Planter unit test stand

    Science.gov (United States)

    A planter test stand was developed to evaluate individual row-crop metering units in early 2013. This test stand provided the ability to quantify actual seed metering in terms of population, seed spacing, skips, and multiples over a range of meter RPMs and vacuum pressures. Preliminary data has been...

  5. Variable Attitude Test Stand

    Data.gov (United States)

    Federal Laboratory Consortium — The Variable Attitude Test Stand designed and built for testing of the V-22 tilt rotor aircraft propulsion system, is used to evaluate the effect of aircraft flight...

  6. Stand for testing the electrical race car engine

    Science.gov (United States)

    Baier, M.; Franiasz, J.; Mierzwa, P.; Wylenzek, D.

    2015-11-01

    An engine test stand created especially for research of electrical race car is described in the paper. The car is an aim of Silesian Greenpower project whose participants build and test electrical vehicles to take part in international races in Great Britain. The engine test stand is used to test and measure the characteristics of vehicles and their engines. It has been designed particularly to test the electric cars engineered by students of Silesian Greenpower project. The article contains a description how the test stand works and shows its versatility in many areas. The paper presents both construction of the test stand, control system and sample results of conducted research. The engine test stand was designed and modified using PLM Siemens NX 8.5. The construction of the test stand is highly modular, which means it can be used both for testing the vehicle itself or for tests without the vehicle. The test stand has its own wheel, motor, powertrain and braking system with second engine. Such solution enables verifying various concepts without changing the construction of the vehicle. The control system and measurement system are realized by enabling National Instruments product myRIO (RIO - Reconfigurable Input/Output). This controller in combination with powerful LabVIEW environment performs as an advanced tool to control torque and speed simultaneously. It is crucial as far as the test stand is equipped in two motors - the one being tested and the braking one. The feedback loop is realized by an optical encoder cooperating with the rotor mounted on the wheel. The results of tests are shown live on the screen both as a chart and as single values. After performing several tests there is a report generated. The engine test stand is widely used during process of the Silesian Greenpower vehicle design. Its versatility enables powertrain testing, wheels and tires tests, thermal analysis and more.

  7. High-voltage test stand at Livermore

    International Nuclear Information System (INIS)

    Smith, M.E.

    1977-01-01

    This paper describes the present design and future capability of the high-voltage test stand for neutral-beam sources at Lawrence Livermore Laboratory. The stand's immediate use will be for testing the full-scale sources (120 kV, 65 A) for the Tokamak Fusion Test Reactor. It will then be used to test parts of the sustaining source system (80 kV, 85 A) being designed for the Magnetic Fusion Test Facility. Following that will be an intensive effort to develop beams of up to 200 kV at 20 A by accelerating negative ions. The design of the test stand features a 5-MVA power supply feeding a vacuum tetrode that is used as a switch and regulator. The 500-kW arc supply and the 100-kW filament supply for the neutral-beam source are battery powered, thus eliminating one or two costly isolation transformers

  8. Assembly and installation of the large coil test facility test stand

    International Nuclear Information System (INIS)

    Queen, C.C. Jr.

    1983-01-01

    The Large Coil Test Facility (LCTF) was built to test six tokamak-type superconducting coils, with three to be designed and built by US industrial teams and three provided by Japan, Switzerland, and Euratom under an international agreement. The facility is designed to test these coils in an environment which simulates that of a tokamak. The heart of this facility is the test stand, which is made up of four major assemblies: the Gravity Base Assembly, the Bucking Post Assembly, the Torque Ring Assembly, and the Pulse Coil Assembly. This paper provides a detailed review of the assembly and installation of the test stand components and the handling and installation of the first coil into the test stand

  9. Planned Experiments on the Princeton Advanced Test Stand

    Science.gov (United States)

    Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I.; Davidson, R. C.

    2010-11-01

    The Princeton Advanced Test Stand (PATS) device is an experimental facility based on the STS-100 high voltage test stand transferred from LBNL. It consists of a multicusp RF ion source, a pulsed extraction system capable of forming high-perveance 100keV ion beams, and a large six-foot-long vacuum with convenient access for beam diagnostics. This results in a flexible system for studying high perveance ion beams relevant to NDCX-I/II, including experiments on beam neutralization by ferroelectric plasma sources (FEPS) being developed at PPPL. Research on PATS will concern the basic physics of beam-plasma interactions, such as the effects of volume neutralization on beam emittance, as well as optimizing technology of the FEPS. PATS combines the advantage of an ion beam source and a large-volume plasma source in a chamber with ample access for diagnostics, resulting in a robust setup for investigating and improving relevant aspects of neutralized drift. There are also plans for running the ion source with strongly electro-negative gases such as chlorine, making it possible to extract positive or negative ion beams.

  10. Poisson simulation for high voltage terminal of test stand for 1MV electrostatic accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae-Hoon; Kim, Jeong-Tae; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Yu-Seok [Dongguk Univ.., Gyeongju (Korea, Republic of)

    2014-10-15

    KOMAC provide ion beam to user which energy range need to expand to MeV range and develop 1 MV electrostatic accelerator. The specifications of the electrostatic accelerator are 1MV acceleration voltage, 10 mA peak current and variable gas ion. We are developing test stand before set up 1 MV electrostatic accelerator. The test stand voltage is 300 kV and operating time is 8 hours. The test stand is consist of 300 kV high voltage terminal, DC-AC-DC inverter, power supply device inside terminal, 200MHz RF power, 5 kV extraction power supply, 300 kV accelerating tube and vacuum system.. The beam measurement system and beam dump will be installed next to accelerating tube. Poisson code simulation results of the high voltage terminal are presented in this paper. Poisson code has been used to calculate the electric field for high voltage terminal. The results of simulation were verified with reasonable results. The poisson code structure could be apply to the high voltage terminal of the test stand.

  11. Poisson simulation for high voltage terminal of test stand for 1MV electrostatic accelerator

    International Nuclear Information System (INIS)

    Park, Sae-Hoon; Kim, Jeong-Tae; Kwon, Hyeok-Jung; Cho, Yong-Sub; Kim, Yu-Seok

    2014-01-01

    KOMAC provide ion beam to user which energy range need to expand to MeV range and develop 1 MV electrostatic accelerator. The specifications of the electrostatic accelerator are 1MV acceleration voltage, 10 mA peak current and variable gas ion. We are developing test stand before set up 1 MV electrostatic accelerator. The test stand voltage is 300 kV and operating time is 8 hours. The test stand is consist of 300 kV high voltage terminal, DC-AC-DC inverter, power supply device inside terminal, 200MHz RF power, 5 kV extraction power supply, 300 kV accelerating tube and vacuum system.. The beam measurement system and beam dump will be installed next to accelerating tube. Poisson code simulation results of the high voltage terminal are presented in this paper. Poisson code has been used to calculate the electric field for high voltage terminal. The results of simulation were verified with reasonable results. The poisson code structure could be apply to the high voltage terminal of the test stand

  12. A Cryogenic Test Stand for Large Superconducting Solenoid Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Rabehl, R. [Fermilab; Carcagno, R. [Fermilab; Nogiec, J. [Fermilab; Orris, D. [Fermilab; Soyars, W. [Fermilab; Sylvester, C. [Fermilab

    2013-01-01

    A new test stand for testing large superconducting solenoid magnets at the Fermilab Central Helium Liquifier (CHL) has been designed, and operated. This test stand has been used to test a coupling coil for the Muon Ionization Cooling Experiment (MICE), and future uses include solenoids for the Fermilab mu2e experiment. This paper describes the test stand design and operation including controlled cool-down and warm-up. Overviews of the process controls system and the quench management system are also included.

  13. Beam Profile Measurement of 300 kV Ion Source Test Stand for 1 MV Electrostatic Accelerator

    International Nuclear Information System (INIS)

    Park, Sae-Hoon; Kim, Yu-Seok; Kim, Dae-Il; Kwon, Hyeok-Jung; Cho, Yong-Sub

    2015-01-01

    In this paper, RF ion source, test stand of the ion source and its test results are presented. Beam profile was measured at the downstream from the accelerating tube and at the beam dump by using BPM and wire scanner. The RF ion source of the test stand is verified by measuring the total beam current with a faraday cup in the chamber. The KOMAC (KOrea Multi-purpose Accelerator Complex) has been developing a 300 kV ion source test stand for a 1 MV electrostatic accelerator. An ion source and accelerating tube will be installed in a high pressure vessel. The ion source in a high pressure vessel requires high reliability. To confirm the stable operation of the ion source, a test stand was proposed and developed. The ion source will be tested at the test stand to verify its long-term operation conditions. The test stand consists of a 300 kV high voltage terminal, a battery for the ion source power, a 60 Hz inverter, a 200 MHz RF power, a 5 kV extraction power supply, a 300 kV accelerating tube, and a vacuum system. The beam profile monitor was installed at the downstream from the accelerating tube. Wire scanner and faraday-cup was installed at the end of the chamber

  14. Beam Profile Measurement of 300 kV Ion Source Test Stand for 1 MV Electrostatic Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae-Hoon; Kim, Yu-Seok [Dongguk University, Gyeonju (Korea, Republic of); Kim, Dae-Il; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Multipurpose Accelerator Complex, Gyeongju (Korea, Republic of)

    2015-10-15

    In this paper, RF ion source, test stand of the ion source and its test results are presented. Beam profile was measured at the downstream from the accelerating tube and at the beam dump by using BPM and wire scanner. The RF ion source of the test stand is verified by measuring the total beam current with a faraday cup in the chamber. The KOMAC (KOrea Multi-purpose Accelerator Complex) has been developing a 300 kV ion source test stand for a 1 MV electrostatic accelerator. An ion source and accelerating tube will be installed in a high pressure vessel. The ion source in a high pressure vessel requires high reliability. To confirm the stable operation of the ion source, a test stand was proposed and developed. The ion source will be tested at the test stand to verify its long-term operation conditions. The test stand consists of a 300 kV high voltage terminal, a battery for the ion source power, a 60 Hz inverter, a 200 MHz RF power, a 5 kV extraction power supply, a 300 kV accelerating tube, and a vacuum system. The beam profile monitor was installed at the downstream from the accelerating tube. Wire scanner and faraday-cup was installed at the end of the chamber.

  15. LAB3 Cosmic Ray Test Stand Analysis of Steel Stack Supports

    International Nuclear Information System (INIS)

    Cease, H.

    1998-01-01

    A cosmic ray test stand is being constructed at Lab 3. The stand consists of two stacks of steel plates one resting on top of the other. The top stack is composed of 6 plates of steel making an overall stack size of 34.5-inch x 40-inch x 99-inch. The bottom stack also has 6 layers of plate making an overall size of approximately 49.5-inch x 82-inch x 99-inch. The bottom stack is supported with three support legs. See drawing 3823.000ME-900428 for the individual plate orientation. The minimum support leg size and necessary welds between plates are determined.

  16. Isopropyl alcohol tank installed at A-3 Test Stand

    Science.gov (United States)

    2009-01-01

    An isopropyl alcohol (IPA) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen IPA, water and liquid oxygen (LOX) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  17. High-voltage terminal test of a test stand for a 1-MV electrostatic accelerator

    Science.gov (United States)

    Park, Sae-Hoon; Kim, Yu-Seok

    2015-10-01

    The Korea Multipurpose Accelerator Complex has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source and accelerating tube will be installed in a high-pressure vessel. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz radio-frequency power supply, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. The results of the 300-kV high-voltage terminal tests are presented in this paper.

  18. Test Stand for Linear Induction Accelerator Optimization

    International Nuclear Information System (INIS)

    Ong, M; DeHope, B; Griffin, K; Goerz, D; Kihara, R; Vogtlin, G; Zentler, J M; Scarpetti, R

    2003-01-01

    Lawrence Livermore National Laboratory has designed and constructed a test stand to improve the voltage regulation in our Flash X-Ray (FXR) accelerator cell. The goal is to create a more mono-energetic electron beam that will create an x-ray source with a smaller spot size. Studying the interaction of the beam and pulse-power system with the accelerator cell will improve the design of high-current accelerators at Livermore and elsewhere. On the test stand, a standard FXR cell is driven by a flexible pulse-power system and the beam current is simulated with a switched center conductor. The test stand is fully instrumented with high-speed digitizers to document the effect of impedance mismatches when the cell is operated under various full-voltage conditions. A time-domain reflectometry technique was also developed to characterize the beam and cell interactions by measuring the impedance of the accelerator and pulse-power component. Computer models are being developed in parallel with the testing program to validate the measurements and evaluate different design changes. Both 3D transient electromagnetic and circuit models are being used

  19. A Cryogenic Test Stand for LHC Quadrupole Magnets

    International Nuclear Information System (INIS)

    Carcagno, R.H.; Huang, Y.; Orris, D.F.; Peterson, T.J.; Rabehl, R.J.

    2004-01-01

    A new test stand for testing LHC interaction region (IR) quadrupole magnets at the Fermilab Magnet Test Facility has been designed and operated. The test stand uses a double bath system with a lambda plate to provide the magnet with a stagnant bath of pressurized He II at 1.9 K and 0.13 MPa. A cryostated magnet 0.91 m in diameter and up to 13 m in length can be accommodated. This paper describes the system design and operation. Issues related to both 4.5 K and 1.9 K operations and magnet quenching are highlighted. An overview of the data acquisition and cryogenics controls systems is also included

  20. HISTRAP [Heavy Ion Storage Ring for Atomic Physics] vacuum test stand for pressures of 10-12 Torr

    International Nuclear Information System (INIS)

    Johnson, J.W.; Atkins, W.H.; Dowling, D.T.; McConnell, J.W.; Milner, W.T.; Olsen, D.K.

    1988-01-01

    HISTRAP, Heavy Ion Storage Ring for Atomic Physics, is a proposed synchrotron/cooler/storage ring accelerator optimized for advanced atomic physics research. The ring has a circumference of 46.8 m, a bore diameter of about 15 cm, and requires a vacuum of 10 -12 Torr in order to decelerate highly-charged very-heavy ions down to low energies. To be able to test components and procedures to achieve this pressure, a test stand approximately modeling one-sixteenth of the ring vacuum chamber has been built. The 3.5-m-long test stand has been fabricated from 10-cm-diameter components, with 316LN stainless steel flanges. Prior to assembly, these components were vacuum fired at 950/degree/C at a pressure of 10 -4 Torr. The test stand is bakeable in situ at 300/degree/C. Pumping is achieved with two 750-L/s titanium sublimator pumps and one 60-L/s ion pump. Pressure is measured with two extractor ion gauges and a 10 -14 PP RGA. The roughing for the test stand consists of cryosorption pumps followed by a cryopump. A pressure of 4 x 10 -12 Torr has been achieved. 7 refs., 5 figs

  1. Reliability and sensitivity to change of the timed standing balance test in children with down syndrome

    Directory of Open Access Journals (Sweden)

    Vencita Priyanka Aranha

    2016-01-01

    Full Text Available Objective: To estimate the reliability and sensitivity to change of the timed standing balance test in children with Down syndrome (DS. Methods: It was a nonblinded, comparison study with a convenience sample of subjects consisting of children with DS (n = 9 aged 8–17 years. The main outcome measure was standing balance which was assessed using timed standing balance test, the time required to maintain in four conditions, eyes open static, eyes closed static, eyes open dynamic, and eyes closed dynamic. Results: Relative reliability was excellent for all four conditions with an Interclass Correlation Coefficient (ICC ranging from 0.91 to 0.93. The variation between repeated measurements for each condition was minimal with standard error of measurement (SEM of 0.21–0.59 s, suggestive of excellent absolute reliability. The sensitivity to change as measured by smallest real change (SRC was 1.27 s for eyes open static, 1.63 s for eyes closed static, 0.58 s for eyes open dynamic, and 0.61 s for eyes closed static. Conclusions: Timed standing balance test is an easy to administer test and sensitive to change with strong absolute and relative reliabilities, an important first step in establishing its utility as a clinical balance measure in children with DS.

  2. Self-consistent nonlinear transmission line model of standing wave effects in a capacitive discharge

    International Nuclear Information System (INIS)

    Chabert, P.; Raimbault, J.L.; Rax, J.M.; Lieberman, M.A.

    2004-01-01

    It has been shown previously [Lieberman et al., Plasma Sources Sci. Technol. 11, 283 (2002)], using a non-self-consistent model based on solutions of Maxwell's equations, that several electromagnetic effects may compromise capacitive discharge uniformity. Among these, the standing wave effect dominates at low and moderate electron densities when the driving frequency is significantly greater than the usual 13.56 MHz. In the present work, two different global discharge models have been coupled to a transmission line model and used to obtain the self-consistent characteristics of the standing wave effect. An analytical solution for the wavelength λ was derived for the lossless case and compared to the numerical results. For typical plasma etching conditions (pressure 10-100 mTorr), a good approximation of the wavelength is λ/λ 0 ≅40 V 0 1/10 l -1/2 f -2/5 , where λ 0 is the wavelength in vacuum, V 0 is the rf voltage magnitude in volts at the discharge center, l is the electrode spacing in meters, and f the driving frequency in hertz

  3. Stand for visual ultrasonic testing of spent fuel

    International Nuclear Information System (INIS)

    Czajkowski, W.; Borek-Kruszewska, E.

    2001-01-01

    A stand for visual and ultrasonic testing of spent fuel, constructed under Strategic Governmental Programme for management of spent fuel and radioactive waste, is presented in the paper. The stand, named 'STEND-1', built up at the Institute of Atomic Energy in Swjerk, is appointed for underwater visual testing of spent fuel elements type MR6 and WWR by means of TV-CCD camera and image processing system and for ultrasonic scanning of external surface of these elements by means of video scan immersion transducer and straight UHT connector. 'STEND-1' is built using flexible in use, high-tensile, anodized aluminum profiles. All the profiles feature longitudinal grooves to accommodate connecting elements and for the attachment of accessories at any position. They are also characterised by straight-through core bores for use with standard fastening elements and to accommodate accessory components. Stand, equipped with automatic control and processing system based on personal computer, may be manually or automatically controlled. Control system of movements of the camera in the vertical axis and rotational movement of spent fuel element permits to fix chosen location of fuel element with accuracy better than 0.1 mm. High resolution of ultrasonic method allows to record damages of outer surface of order 0.1 mm. The results of visual testing of spent fuel are recorded on video tape and then may be stored on the hard disc of the personal computer and presented in shape of photo or picture. Only selected damage surfaces of spent fuel elements are tested by means of ultrasonic scanning. All possibilities of the stand and results of visual testing of spent fuel type WWR are presented in the paper. (author)

  4. Data acquisition system for PLT Neutral Beam Test Stand

    International Nuclear Information System (INIS)

    Francis, J.E. Jr.; Hammons, C.E.

    1977-01-01

    The PLT Neutral Beam Test Stand at Oak Ridge National Laboratory was constructed to test and condition powerful neutral beam sources for the Princeton Large Torus experiment at Princeton Plasma Physics Laboratory. The data acquisition system for the test stand monitors the beam characteristics and power output to determine if the beam is operating at its design specifications. The high speed of the computer system is utilized to provide near-real-time analysis of experimental data. The analysis of the data is presented as numerical tabulation and graphic display

  5. Comparison of Test Stand and Helicopter Oil Cooler Bearing Condition Indicators

    Science.gov (United States)

    Dempsey, Paula J.; Branning, Jeremy; Wade, Damiel R.; Bolander, Nathan

    2010-01-01

    The focus of this paper was to compare the performance of HUMS condition indicators (CI) when detecting a bearing fault in a test stand or on a helicopter. This study compared data from two sources: first, CI data collected from accelerometers installed on two UH-60 Black Hawk helicopters when oil cooler bearing faults occurred, along with data from helicopters with no bearing faults; and second, CI data that was collected from ten cooler bearings, healthy and faulted, that were removed from fielded helicopters and installed in a test stand. A method using Receiver Operating Characteristic (ROC) curves to compare CI performance was demonstrated. Results indicated the bearing energy CI responded differently for the helicopter and the test stand. Future research is required if test stand data is to be used validate condition indicator performance on a helicopter.

  6. Cryogenics for a vertical test stand facility for testing superconducting radio frequency cavities at RRCAT

    International Nuclear Information System (INIS)

    Gupta, Prabhat Kumar; Kumar, Manoj; Kush, P.K.

    2015-01-01

    Vertical Test Stand (VTS) Facility is located in a newly constructed building of Cryo-Engineering and Cryo-Module Development Division (CCDD). This test facility is one of the important facilities to develop SCRF technologies for superconducting accelerators like Indian Spallation Neutron Source. VTS has to be used for regular testing of the Superconducting Radio Frequency (SRF) Niobium cavities at nominal frequency of 1.3 GHz/ 650 MHz at 4 K / 2 K liquid helium (LHe) bath temperatures. Testing of these cavities at 2 K evaluates cavity processing methods, procedures and would also serve as a pre-qualification test for cavity to test it in horizontal cryostat, called horizontal test stand, with other cavity components such as tuner and helium vessel. Cryogenic technologies play a major role in these cavity testing facilities. Achieving and maintaining a stable temperature of 2 K in these test stands on regular and reliable basis is a challenging task and require broad range of cryogenic expertise, large scale system level understanding and many in-house technological and process developments. Furthermore this test stand will handle large amount of liquid helium. Therefore, an appropriately designed infrastructure is required to handle such large amount of helium gas generated during the operation of VTS .This paper describes the different cryogenic design aspects, initial cryogenic operation results and different cryogenic safety aspects. (author)

  7. A cryogenic test stand for full length SSC magnets with superfluid capability

    International Nuclear Information System (INIS)

    Peterson, T.J.; Mazur, P.O.

    1989-02-01

    The Fermilab Magnet Test Facility performs testing of the full scale SSC magnets on test stands capable of simulating the cryogenic environment of the SSC main ring. One of these test stands, Stand 5, also has the ability to operate the magnet under test at temperatures from 1.8K to 4.5K with either supercritical helium or subcooled liquid, providing at least 25 Watts of refrigeration. At least 50 g/s flow is available from 2.3K to 4.5K, whereas superfluid operation occurs with zero flow. Cooldown time from 4.5K to 1.8K is 1.5 hours. A maximum current capability of 10,000 amps is provided, as is instrumentation to monitor and control the cryogenic conditions. This paper describes the cryogenic design of this test stand. 8 refs., 6 figs

  8. Engineering design of vertical test stand cryostat

    International Nuclear Information System (INIS)

    Suhane, S.K.; Sharma, N.K.; Raghavendra, S.; Joshi, S.C.; Das, S.; Kush, P.K.; Sahni, V.C.; Gupta, P.D.; Sylvester, C.; Rabehl, R.; Ozelis, J.

    2011-01-01

    Under Indian Institutions and Fermilab collaboration, Raja Ramanna Centre for Advanced Technology and Fermi National Accelerator Laboratory are jointly developing 2K Vertical Test Stand (VTS) cryostats for testing SCRF cavities at 2K. The VTS cryostat has been designed for a large testing aperture of 86.36 cm for testing of 325 MHz Spoke resonators, 650 MHz and 1.3 GHz multi-cell SCRF cavities for Fermilab's Project-X. Units will be installed at Fermilab and RRCAT and used to test cavities for Project-X. A VTS cryostat comprises of liquid helium (LHe) vessel with internal magnetic shield, top insert plate equipped with cavity support stand and radiation shield, liquid nitrogen (LN 2 ) shield and vacuum vessel with external magnetic shield. The engineering design and analysis of VTS cryostat has been carried out using ASME B and PV Code and Finite Element Analysis. Design of internal and external magnetic shields was performed to limit the magnetic field inside LHe vessel at the cavity surface 2 shield has been performed to check the effectiveness of LN 2 cooling and for compliance with ASME piping code allowable stresses.

  9. HESTIA Commodities Exchange Pallet and Sounding Rocket Test Stand

    Science.gov (United States)

    Chaparro, Javier

    2013-01-01

    the Commodities Exchange Pallet, I also assisted in preparation for testing the upper stage of a sounding rocket developed as a Center Innovation Fund project. The main objective of this project is to demonstrate the integration between a propulsion system and a solid oxide fuel cell (SOFC). The upper stage and SOFC are scheduled to complete an integrated test in August of 2016. As part of preparation for scheduled testing, I was responsible for designing the upper stage's test stand/support structure and main engine plume deflector to be used during hot-fire testing (fig. 3). The structural components of the test stand need to meet safety requirements for operation of the propulsion system, which consist of a 100 pounds-thrust main engine and two 15 pounds-thrust reaction control thrusters. My main accomplishment for this project was the completion of the design and the parts selection for construction of the structure, scheduled to begin late April of 2016.

  10. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions

    Science.gov (United States)

    Giffin, Paxton K.; Parsons, Michael S.; Unz, Ronald J.; Waggoner, Charles A.

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m3/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  11. Beam instrumentation for an ISOL test stand

    International Nuclear Information System (INIS)

    Mackenzie, G.H.; Dombsky, M.; Rawnsley, W.; Stanford, G.; Yin, Y.; Novikov, A.

    1995-09-01

    TRIUMF is constructing a test bed for the first stages of the proposed TISAC accelerated radioactive beam facility. The authors will present the requirements for the diagnostic system for this test stand and describe the design and development work underway. Scintillators, beamstops and a Faraday Cup have been tested using stable, mass analyzed, 12 keV beams of ions from mass 14 to 132. The design of a linear drive, with 10 microm resolution, for scanning wires and slits has begun

  12. Beam instrumentation for an ISOL test stand

    International Nuclear Information System (INIS)

    Mackenzie, G.H.; Dombsky, M.; Rawnsley, W.; Stanford, G.; Yin, Y.; Novikov, A.

    1995-09-01

    TRIUMF is constructing a test bed for the first stages of the proposed TISAC accelerated radioactive beam facility. We will present the requirements for the diagnostic system for this test stand and describe the design and development work underway. Scintillators, beamstops and Faraday Cup have been tested using stable, mass analyzed, 12 keV beams of ions from mass 14 to 132. The design of a linear drive, with 10 μm resolution, for scanning wires and slits has begun. (author)

  13. J-2 Engine ready to go into test stand

    Science.gov (United States)

    1965-01-01

    Two technicians watch carefully as cables prepare to lift a J-2 engine into a test stand. The J-2 powered the second stage and the third stage of the Saturn V moon rocket. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  14. Using GIFTS on the Cray-1 for the large coil test facility test: stand design analysis

    International Nuclear Information System (INIS)

    Baudry, T.V.; Gray, W.H.

    1981-06-01

    The GIFTS finite element program has been used extensively throughout the Large Coil Test Facility (LCTF) test stand design analysis. Effective use has been made of GIFTS both as a preprocessor to other finite element programs and as a complete structural analysis package. The LCTF test stand design involved stress analysis ranging from simple textbook-type problems to very complicated three-dimensional structural problems. Two areas of the design analysis are discussed

  15. Stand development and reliability tests of the thermal monitoring means for NPP

    International Nuclear Information System (INIS)

    Nalivaev, V.I.; Nikul'shin, V.S.; Kichigin, A.B.; Dirin, V.F.

    2003-01-01

    The paper is devoted to the reliability tests of thermoelectric thermometers and resistance thermometers during their operation in the nominal mode. Five stands Reliability are developed and operate for realization of tests of all manufactured thermal converters. delivered at NPP. Description of all stands are presented [ru

  16. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    Science.gov (United States)

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  17. Measurement properties and feasibility of clinical tests to assess sit-to-stand/stand-to-sit tasks in subjects with neurological disease: a systematic review

    Directory of Open Access Journals (Sweden)

    Paula F. S. Silva

    2014-04-01

    Full Text Available BACKGROUND: Subjects with neurological disease (ND usually show impaired performance during sit-to-stand and stand-to-sit tasks, with a consequent reduction in their mobility levels. OBJECTIVE: To determine the measurement properties and feasibility previously investigated for clinical tests that evaluate sit-to-stand and stand-to-sit in subjects with ND. METHOD: A systematic literature review following the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses protocol was performed. Systematic literature searches of databases (MEDLINE/SCIELO/LILACS/PEDro were performed to identify relevant studies. In all studies, the following inclusion criteria were assessed: investigation of any measurement property or the feasibility of clinical tests that evaluate sit-to-stand and stand-to-sit tasks in subjects with ND published in any language through December 2012. The COSMIN checklist was used to evaluate the methodological quality of the included studies. RESULTS: Eleven studies were included. The measurement properties/feasibility were most commonly investigated for the five-repetition sit-to-stand test, which showed good test-retest reliability (Intraclass Correlation Coefficient:ICC=0.94-0.99 for subjects with stroke, cerebral palsy and dementia. The ICC values were higher for this test than for the number of repetitions in the 30-s test. The five-repetition sit-to-stand test also showed good inter/intra-rater reliabilities (ICC=0.97-0.99 for stroke and inter-rater reliability (ICC=0.99 for subjects with Parkinson disease and incomplete spinal cord injury. For this test, the criterion-related validity for subjects with stroke, cerebral palsy and incomplete spinal cord injury was, in general, moderate (correlation=0.40-0.77, and the feasibility and safety were good for subjects with Alzheimer's disease. CONCLUSIONS: The five-repetition sit-to-stand test was used more often in subjects with ND, and most of the measurement

  18. The stand-alone test and decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Thorlund-Petersen, Lars

    2000-01-01

    The rule of decreasing serial cost sharing defined in de Frutos [1] over the class of concave cost functions may violate the important stand-alone test. Sufficient conditions for the test to be satisfied are given, in terms of individual rationality as well as coalitional stability...

  19. Mobile test stand for evaluation of electric power plants for unmanned aircraft

    Directory of Open Access Journals (Sweden)

    Serbezov Vladimir

    2017-01-01

    Full Text Available The absence of accurate performance data is a common problem with most civilian unmanned aerial vehicle (UAV power plant producers. The reasons for this are the small size of most of the manufacturers and the high price of precise wind tunnel testing and computer simulations. To overcome this problem at Dronamics Ltd., with support from the Department of Aeronautics of TU-Sofia, a mobile test stand for evaluation of electric power plants for unmanned aircraft was developed. The stand may be used statically, or may be installed on the roof of an automobile. The measurement system of the stand is based on popular hardware that is used in radio controlled models and in general automation. The verification of the measurement system is performed by comparing static test results with data published by the manufacturer of the tested electric motor. Tests were carried out with 2 different types of propellers and the results were compared with published results for common propellers as well as with results of theoretical studies. The results are satisfactory for practical applications. The use of this type of test stands can be a cheap and effective alternative for research and development start-up companies like Dronamics.

  20. Beam Extraction for 1-MV Electrostatic Accelerator at the 300 kV Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae-Hoon; Kim, Yu-Seok [Dongguk University, Seoul (Korea, Republic of); Kwon, Hyeok-Jung; Cho, Yong-Sub [KOMAC, Gyeongju (Korea, Republic of)

    2015-05-15

    The Korea Multipurpose Accelerator Complex (KOMAC) has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz RF power, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. A beam extraction experiment for the test stand was performed, and the beam current was measured using a faraday cup in the chamber. A beam extraction results for the RF ion source will be presented. Beam extraction from the RF ion source of the test stand is verified by measuring the beam current with a faraday cup in the chamber. Thus far NI Labview, PLC and faraday cup have been used to measure the beam current. The OPC server is useful for monitoring the PLC values. The average beam current of (a), (b) and (c) shown in figure 2 are 110.241µA, 105.8597µA and 103.5278µA respectively.

  1. Pilot Field Test: Use of a Compression Garment During a Stand Test After Long-Duration Space Flight

    Science.gov (United States)

    Laurie, S. S.; Stenger, M. B.; Phillips, T. R.; Lee, S. M. C.; Cerisano, J.; Kofman, I.; Reschke, M.

    2016-01-01

    Orthostatic intolerance (OI) is a concern for astronauts returning from long-duration space flight. One countermeasure that has been used to protect against OI after short-duration bed rest and space flight is the use of lower body and abdominal compression garments. However, since the end of the Space Shuttle era we have not been able to test crewmembers during the first 24 hours after landing on Earth. NASA's Pilot Field Test provided us the opportunity to test cardiovascular responses of crewmembers wearing the Russian Kentavr compression garment during a stand test at multiple time points throughout the first 24 hours after landing. HYPOTHESIS We hypothesized that the Kentavr compression garment would prevent an increase in heart rate (HR) >15 bpm during a 3.5-min stand test. METHODS: The Pilot Field Test was conducted up to 3 times during the first 24 hours after crewmembers returned to Earth: (1) either in a tent adjacent to the Soyuz landing site in Kazakhstan (approx.1 hr) or after transportation to the Karaganda airport (approx. 4 hr); (2) during a refueling stop in Scotland (approx.12 hr); and (3) upon return to NASA Johnson Space Center (JSC) (approx.24 hr). We measured HR and arterial pressure (finger photoplethysmography) for 2 min while the crewmember was prone and throughout 3.5 min of quiet standing. Eleven crewmembers consented to participate; however, 2 felt too ill to start the test and 1 stopped 30 sec into the stand portion of the test. Of the remaining 8 crewmembers, 2 did not wear the Russian Kentavr compression garment. Because of inclement weather at the landing site, 5 crewmembers were flown by helicopter to the Karaganda airport before initial testing and received intravenous saline before completing the stand test. One of these crewmembers wore only the portion of the Russian Kentavr compression garment that covered the lower leg and thus lacked thigh and abdominal compression. All crewmembers continued wearing the Russian Kentavr

  2. Optimisation of the test policy of stand-by systems

    International Nuclear Information System (INIS)

    Signoret, J.P.; Muron, O.; Cohen, G.

    1980-09-01

    In a nuclear power plant there are several systems which are on stand-by position as, for instance, safety systems. These stand-by systems have to be ready to start as soon as any situation for which they have be designed occurs. A test policy is then necessary in order to know the state of such a system and repair the possible failures. The tests are normally performed at regular intervals of time according to a scheduled sequence. We have already shown during the 'IIIeme Congres National de Fiabilite' held in Perros-Guirec in 1976 how it is possible in this case to find the optimum test interval leading to the best mean availability of the system. It is, in fact, possible, to improve that by considering that if the test interval is fixed 'a priori' this does not allow to take into account information we have on the system state every time [fr

  3. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion...... strength (Spearman rho = -0.44, P = 0.016). CONCLUSIONS: Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain....

  4. SSRL photocathode RF gun test stand

    International Nuclear Information System (INIS)

    Hernandez, M.; Baltay, M.; Boyce, A.

    1995-01-01

    A photocathode RF gun test stand designed for the production and study of high brightness electron beams will be constructed at SSRL. The beam will be generated from a laser driven third generation photocathode RF gun being developed in collaboration with BNL, LBL, and UCLA. The 3-5 [MeV] beam from the gun will be accelerated using a SLAC three meter S-band accelerator section, in order to achieve the desired low emittance beam, emittance compensation with solenoidal focusing will be employed

  5. 1 MW, 352.2 MHz, CW and Pulsed RF test stand

    International Nuclear Information System (INIS)

    Badapanda, M.K.; Tripathi, Akhilesh; Upadhyay, Rinki; Tyagi, Rajiv; Hannurkar, P.R.

    2011-01-01

    A 1 MW, 352.2 MHz, RF test stand based on Thales make TH 2089 klystron amplifier is being developed at Raja Ramanna Centre for Advanced Technology (RRCAT), Indore for characterization and qualification of RF components, cavities and related subsystems. Provision to vary RF power from 50 kW to 1 MW with adequate flexibility for testing wide range of HV components, RF components and cavities is incorporated in this test stand. The paper presents a brief detail of various power supplies like high voltage cathode bias power supply, modulating anode power supply, filament power supply, electromagnet power supplies and ion pump power supplies along with their interconnections for biasing TH 2089 klystron amplifier. A digital control and interlock system is being developed to realize proper sequence of operation of various power supplies and to monitor the status of crucial parameters in this test set up. This RF test stand will be a unique national facility, capable of providing both CW and pulse RF power for realizing reliable RF power sources for various projects including the development of high energy proton linac under ADSS program of the Department of Atomic Energy. (author)

  6. Construction of a test stand for the measurement of the light output uniformity of CALIFA crystals

    Energy Technology Data Exchange (ETDEWEB)

    Susenburger, Markus; Ignatov, Alexander; Kroell, Thorsten [Technische Universitaet Darmstadt, Darmstadt (Germany)

    2016-07-01

    Currently, the Facility for Antiproton and Ion Research (FAIR) at GSI in Darmstadt is under construction. One experiment at GSI and FAIR is called Reactions with Relativistic Radioactive Beams (R{sup 3}B). A key component of the R{sup 3}B is the CALorimeter for In Flight detection of γ-rays and light charged pArticles (CALIFA), which will surround the R{sup 3}B target chamber and will be capable of the detection of γ-rays in a wide energy range from 100 keV to 30 MeV as well as of light charged particles. CALIFA is built out of two parts, the so called CALIFA barrel and CALIFA endcap. The barrel consists of 1952 CsI(Tl) detector crystals which have to fulfill several specifications. One of these specifications is the uniformity of the light output. Depending on the location of the deposited energy, the crystal's light output varies due to optical focusing effects. This behavior can be manipulated by lapping the crystal's surface. The aim of this work is the development of a test stand which will check if the crystals match the requirements according to the light output uniformity. Because of the large number of crystals needed to be tested, the stand automates the test procedure, which guarantees comparable test measurement for all crystals. The development and construction of this stand is reported.

  7. Performance studies of the vibration wire monitor on the test stand with low energy electron beam

    International Nuclear Information System (INIS)

    Okabe, Kota; Yoshimoto, Masahiro; Kinsho, Michikazu

    2015-01-01

    In the high intensity proton accelerator as the Japan Proton Accelerator Research Complex (J-PARC) accelerators, serious radiation and residual dose is induced by a small beam loss such a beam halo. Therefore, diagnostics of the beam halo formation is one of the most important issues to control the beam loss. For the beam halo monitor, the vibration wire monitor (VWM) has a potential for investigating the beam halo and weak beam scanning. The VWM has a wide dynamic range, high resolution and the VWM is not susceptible to secondary electrons and electric noises. We have studied the VWM features as a new beam-halo monitor on the test stand with low energy electron gun. The frequency shift of the irradiated vibration wire was confirmed about wire material and the electron beam profile measured by using the VWM was consistent with the results of the Faraday cup measurement. Also we calculated a temperature distribution on the vibration wire which is irradiated by the electron beam with the numerical simulation. The simulations have been fairly successful in reproducing the transient of the irradiated vibration wire frequency measured by test stand experiments. In this paper, we will report a result of performance evaluation for the VWM on the test stands and discuss the VWM for beam halo diagnostic. (author)

  8. Construction, commissioning and initial operation of 2400W refrigerator and cold test stand for CDM testing

    International Nuclear Information System (INIS)

    Dubbs, J.D.; Kreinbrink, K.

    1994-01-01

    Air Products and CVI collaborated to design, construct and commission a refrigerator, test stands and integrated control system for the General Dynamics Collider Dipole Magnet Cold Test Facility (CTF) in Hammond, LA. The original project schedule required the cold test facility to be operational within 17 months of the notice to proceed. Midway through the project, changes in General Dynamics magnet testing requirements necessitated doubling the plant capacity, but the on stream date for the initial capacity increment could not be relaxed. The Air Products/CVI team had to adapt the project execution strategy to mitigate the schedule impact of the expansion in a cost effective manner without impacting system functionality, quality or safety. An equally challenging aspect of the job was that the (CTF) was being designed while several major systems that would interface with the CTF were being engineered. General Dynamics, Air Products and CVI had to work very closely to manage the interface issues. The teams efforts were very successful. The Hammond refrigerator/liquifier was started up on schedule. The first two test stands are currently being commissioned and will be on stream just six weeks later than the pre-expansion schedule target and all four test stands will be operational in time to support General Dynamics magnet testing requirements

  9. Drive Stands

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrical Systems Laboratory (ESL)houses numerous electrically driven drive stands. A drive stand consists of an electric motor driving a gearbox and a mounting...

  10. Large source test stand for H-(D-) ion source

    International Nuclear Information System (INIS)

    Larson, R.; McKenzie-Wilson, R.

    1981-01-01

    The Brookhaven National Laboratory Neutral Beam Group has constructed a large source test stand for testing of the various source modules under development. The first objective of the BNL program is to develop a source module capable of delivering 10A of H - (D - ) at 25 kV operating in the steady state mode with satisfactory gas and power efficiency. The large source test stand contains gas supply and vacuum pumping systems, source cooling systems, magnet power supplies and magnet cooling systems, two arc power supplies rated at 25 kW and 50 kW, a large battery driven power supply and an extractor electrode power supply. Figure 1 is a front view of the vacuum vessel showing the control racks with the 36'' vacuum valves and refrigerated baffles mounted behind. Figure 2 shows the rear view of the vessel with a BNL Mk V magnetron source mounted in the source aperture and also shows the cooled magnet coils. Currently two types of sources are under test: a large magnetron source and a hollow cathode discharge source

  11. F-15B ACTIVE test stand

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the underside of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the thrust stand being used for ground testing of a new thrust-vectoring concept. The twin-engine F-15 research aircraft is equipped with new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. They give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. Ground testing during the first two weeks of November 1995 went well, and flight tests began in March 1996. These tests could result in significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace.

  12. The front end test stand high performance H- ion source at Rutherford Appleton Laboratory.

    Science.gov (United States)

    Faircloth, D C; Lawrie, S; Letchford, A P; Gabor, C; Wise, P; Whitehead, M; Wood, T; Westall, M; Findlay, D; Perkins, M; Savage, P J; Lee, D A; Pozimski, J K

    2010-02-01

    The aim of the front end test stand (FETS) project is to demonstrate that chopped low energy beams of high quality can be produced. FETS consists of a 60 mA Penning Surface Plasma Ion Source, a three solenoid low energy beam transport, a 3 MeV radio frequency quadrupole, a chopper, and a comprehensive suite of diagnostics. This paper details the design and initial performance of the ion source and the laser profile measurement system. Beam current, profile, and emittance measurements are shown for different operating conditions.

  13. Novel automatic phase lock determination for superconducting cavity tests at vertical test stand at RRCAT

    International Nuclear Information System (INIS)

    Singh, Kunver Adarsh Pratap; Mohania, Praveen; Rajput, Vikas; Baxy, Deodatta; Shrivastava, Purushottam

    2015-01-01

    RRCAT has developed a Vertical Test Stand (VTS) which is used to test the Nb superconducting cavities under cryogenic conditions. In the VTS, RF cavity is characterized for its quality factor variation vs the accelerating gradient. The RF system is an essential part of the VTS which is required to provide stable RF power to the cavity in terms of amplitude, frequency and phase. RF system of VTS consists of several modules including the LLRF system. The LLRF system consists of the 'Frequency Control Module' which controls the input frequency to the SCRF cavity. Due to high quality factor, bandwidth of the cavity is less than 1 Hz. Even slight mechanical vibrations (microphonics) causes change in cavity resonance frequency resulting in total reflection of incident power. A PLL based frequency tracking module has been used to track the resonant frequency of RF cavity. This module changes RF source frequency according to change in Cavity resonance frequency. A novel method using a LabView based computer program has been developed which changes the phase of input RF signal using IQ modulator and monitors the transmitted power, incident and reflected power. The program plots the graph between phase and ratio of transmitted power to incident/reflected power and gives optimum locking phase for operation which has resulted in significant saving in the overall process time for the tests of the cavities in VTS. (author)

  14. Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people

    Directory of Open Access Journals (Sweden)

    Boneth M

    2012-05-01

    Full Text Available Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3, on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95% respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.

  15. Stand tests of the grader unit AKD-2

    Energy Technology Data Exchange (ETDEWEB)

    Kocheskhov, S.M.; Bagley, A.V.; Shalkov, A.V.

    1982-01-01

    Results are presented of stand tests of a static operating grader designed for unmanned extraction of deep beds with programmed control of the unit AKD-2 according to hypsometry of the seam occurrence. Malfunctions in a number of grader assemblies are revealed and eliminated. Parameters are defined which characterize the kinematics and dynamics of the grader mechanism.

  16. Optimization of the stand for test of hybrid rocket engines of solid fuel

    Directory of Open Access Journals (Sweden)

    Zolotorev Nikolay

    2017-01-01

    Full Text Available In the paper the laboratory experimental stand of the hybrid rocket engine of solid fuel to study ballistic parameters of the engine at burning of high-energy materials in flow of hot gas is presented. Mixture of air with nitrogen with a specified content of active oxygen is used as a gaseous oxidizer. The experimental stand has modular design and consists of system of gas supply, system of heating of gas, system for monitoring gas parameters, to which a load cell with a model engine was connected. The modular design of the stand allows to change its configuration under specific objective. This experimental stand allows to conduct a wide range of the pilot studies at interaction of a hot stream of gas with samples high-energy materials.

  17. Project of a test stand for cyclotron ion sources

    International Nuclear Information System (INIS)

    Buettig, H.; Dietrich, J.; Merker, H.; Odrich, H.; Preusche, S.; Weissig, J.

    1978-10-01

    In the work the construction of a test stand for testing and optimization of ion sources of the Rossendorf cyclotron U-120 is represented. The design procedure and the construction of the electromagnet, the vacuum chamber with monant, the vacuum system, the power supply and the detecting system are demonstrated. The results of calculations of the motion of ions in the magnetic field are presented. (author)

  18. Non-radioactive stand-in for radioactive contamination. I. Non-radioactive tests

    International Nuclear Information System (INIS)

    Rohe, M.J.; Rankin, W.N.; Postles, R.L.

    1985-01-01

    Candidate non-radioactive materials for use as a stand-in for radioactive contamination during application of a high-pressure, hot water decontamination were identified and evaluated. A stand-in for radioactive contamination is needed to evaluate the decontaminability of replacement canyon cranes at the manufacturers location where actual radioactive contamination cannot be used. This evaluation was conducted using high-pressure, hot-water at 420 psi, 190 0 F, and 20 gal/min through a 1/8-in.-diam nozzle, the decontamination technique preferred by SRP Separations Department for this application. A non-radioactive stand-in for radioactive contamination was desired that would be removed by direct blast stream contact but would remain intact on surfaces where direct contact does not occur. This memorandum describes identification of candidate non-radioactive stand-in materials and evaluation of these materials in screening tests and tests with high-pressure, hot-water blasting. The following non-radioactive materials were tested: carpenter's line chalk; typing correction fluid; dye penetrant developer; latex paint with attapulyite added; unaltered latex paint; gold enamel; layout fluid; and black enamel. Results show that blue layout fluid and gold enamel have similar adherence that is within the range expected for actual radioactive contamination. White latex paint has less adherence than expected for actual radioactive contamination. The film was removed at a rate of 2 . Black enamel has more adherence than expected from actual radioactive contamination. In these tests ASTM No. 2B surfaces were harder to clean than either ASTM No. 1 or electropolished surfaces which had similar cleaning properties. A 90 0 blast angle was more effective than a 45 0 blast angle. In these tests there was no discernible effect of blast distance between 1 and 3 ft

  19. Performance review of an indigenously developed high power test stand built for the Indian S-band 5 MW pulsed klystron development

    International Nuclear Information System (INIS)

    Shrivastava, Purushottam; Baxy, D.; Mulchandani, J.; Hannurkar, P.R.; Joshi, L.M.

    2003-01-01

    CAT took up development of 5 MW S-Band klystrons indigenously in collaboration with CEERI Pilani. The development of klystron prototype is completed. These klystrons are very crucial devices, for energizing the 10-20 MeV electron accelerators, which are developed in the country for various industrial, medical and scientific applications. A test station has been developed indigenously at CAT for these klystrons. It consists of a 12 MW peak power 130 kV klystron pulse modulator, a 1 : 10 pulse transformer, 130 kV high voltage deck having high voltage pulse divider, pulse current transformer as well indigenously built klystron socket, filament supplies, klystron support structure and pulse transformer oil tank. After development/rigorous testing the test stand was shifted to CEERI and was installed and commissioned there by CAT. Gun collector test module and prototypes of the 5 MW klystron were tested, aged and conditioned at high power using this test stand. The details of the system / test results are discussed

  20. The minimum sit-to-stand height test: reliability, responsiveness and relationship to leg muscle strength.

    Science.gov (United States)

    Schurr, Karl; Sherrington, Catherine; Wallbank, Geraldine; Pamphlett, Patricia; Olivetti, Lynette

    2012-07-01

    To determine the reliability of the minimum sit-to-stand height test, its responsiveness and its relationship to leg muscle strength among rehabilitation unit inpatients and outpatients. Reliability study using two measurers and two test occasions. Secondary analysis of data from two clinical trials. Inpatient and outpatient rehabilitation services in three public hospitals. Eighteen hospital patients and five others participated in the reliability study. Seventy-two rehabilitation unit inpatients and 80 outpatients participated in the clinical trials. The minimum sit-to-stand height test was assessed using a standard procedure. For the reliability study, a second tester repeated the minimum sit-to-stand height test on the same day. In the inpatient clinical trial the measures were repeated two weeks later. In the outpatient trial the measures were repeated five weeks later. Knee extensor muscle strength was assessed in the clinical trials using a hand-held dynamometer. The reliability for the minimum sit-to-stand height test was excellent (intraclass correlation coefficient (ICC) 0.91, 95% confidence interval (CI) 0.81-0.96). The standard error of measurement was 34 mm. Responsiveness was moderate in the inpatient trial (effect size: 0.53) but small in the outpatient trial (effect size: 0.16). A small proportion (8-17%) of variability in minimum sit-to-stand height test was explained by knee extensor muscle strength. The minimum sit-to-stand height test has excellent reliability and moderate responsiveness in an inpatient rehabilitation setting. Responsiveness in an outpatient rehabilitation setting requires further investigation. Performance is influenced by factors other than knee extensor muscle strength.

  1. PROPOSAL FOR BUILD A TEST STAND TO THE STUDY WATER RAM BASED ON THE RECOMMENDATIONS CONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Dariusz GRYGO

    2016-05-01

    Full Text Available The main aim of this article was developed of a test stand to a study physics phenomena accruing at work in a ram water based on the construction recommendations. The experience gained by a number of attempts allowed to the developed construction recommendations that allowed to adjust the test stand to perform various studies of physics phenomena occurring at the work of water ram and easy adaptions to the new requirements. The article includes: the review of the test stands on which performed the study in the history and in the present times, description of the construction recommendations of the universal test stand and the proposal of the test stand developed based on the construction recommendations. Motivation to take up this issue follows from the interest of devices that work in an unconventional way, devices used a renewable energy that can be used in household e.g. to improve their energy balance, delivery water to houses, drinking water for animals, fields irrigation, etc. Analysis of the literature of the water ram, test stands and their performance shown that it is small and typically old development in popular science form. In times of intensive search new sources of renewable energy reactivation of this type equipment may be highly probable.

  2. 1+-n+ ECR ION SOURCE DEVELOPMENT TEST STAND

    International Nuclear Information System (INIS)

    Donald P. May

    2006-01-01

    A test stand for the investigation of 1+-n+ charge boosting using an ECR ion sources is currently being assembled at the Texas A and M Cyclotron Institute. The ultimate goal is to relate the charge-boosting of ions of stable species to possible charge-boosting of ions of radioactive species extracted from the diverse, low-charge-state ion sources developed for radioactive ion beams

  3. Commissioning and First Results from the Fermilab Cryomodule Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Harms, Elvin; et al.

    2017-05-01

    A new test stand dedicated to SRF cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.

  4. Tandem Mirror Experiment-Upgrade neutral beam test stand: A powerful tool for development and quality assurance

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.

    1983-01-01

    During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), a test stand was assembled to develop electronics for the neutral beam system. In the first six months of test stand use the authors operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, the focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance and development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises the final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U. They have also used the test stand to perform a series of physics experiments, including: reducing gas flow through valve and arc chamber characterization, reducing impurities by titanium gettering, and reducing streaming gas using apertures and collisional gas dynamics

  5. Ethernet-based test stand for a CAN network

    Science.gov (United States)

    Ziebinski, Adam; Cupek, Rafal; Drewniak, Marek

    2017-11-01

    This paper presents a test stand for the CAN-based systems that are used in automotive systems. The authors propose applying an Ethernet-based test system that supports the virtualisation of a CAN network. The proposed solution has many advantages compared to classical test beds that are based on dedicated CAN-PC interfaces: it allows the physical constraints associated with the number of interfaces that can be simultaneously connected to a tested system to be avoided, which enables the test time for parallel tests to be shortened; the high speed of Ethernet transmission allows for more frequent sampling of the messages that are transmitted by a CAN network (as the authors show in the experiment results section) and the cost of the proposed solution is much lower than the traditional lab-based dedicated CAN interfaces for PCs.

  6. Are the General Medical Council's Tests of Competence fair to long standing doctors? A retrospective cohort study.

    Science.gov (United States)

    Mehdizadeh, Leila; Sturrock, Alison; Dacre, Jane

    2015-04-21

    The General Medical Council's Fitness to Practise investigations may involve a test of competence for doctors with performance concerns. Concern has been raised about the suitability of the test format for doctors who qualified before the introduction of Single Best Answer and Objective Structured Clinical Examination assessments, both of which form the test of competence. This study explored whether the examination formats used in the tests of competence are fair to long standing doctors who have undergone fitness to practise investigation. A retrospective cohort design was used to determine an association between year of primary medical qualification and doctors' test of competence performance. Performance of 95 general practitioners under investigation was compared with a group of 376 volunteer doctors. We analysed performance on knowledge test, OSCE overall, and three individual OSCE stations using Spearman's correlation and regression models. Doctors under investigation performed worse on all test outcomes compared to the comparison group. Qualification year correlated positively with performance on all outcomes except for physical examination (e.g. knowledge test r = 0.48, p fitness to practise investigation performed less well on the test of competence than their more recently qualified peers under investigation. The performance of the comparator group tended to stay consistent irrespective of year qualified. Our results suggest that the test format does not disadvantage early qualified doctors. We discuss findings in relation to the GMC's fitness to practise procedures and suggest alternative explanations for the poorer performance of long standing doctors under investigation.

  7. Method’s and Test Stand for Electronic PID Controller

    Directory of Open Access Journals (Sweden)

    Cristian Paul Chioncel

    2009-01-01

    Full Text Available The paper presents method’s and a testing stand for electronic controller using for this a signal generator and a digital oscilloscope respectively the virtual instrumentation and the signal acquisitions from the controllers input and output through an data acquisition board and an PC on that Lab View program runs.

  8. Fiber Optic Telemetry System for LLL High-Voltage Test Stand

    International Nuclear Information System (INIS)

    Richter, J.P.

    1977-01-01

    This paper describes the Fiber Optic Telemetry System designed to operate in the hostile particle and electromagnetic radiation environment of the High Voltage Test Stand. It discusses system criteria, components, packaging, and performance. In all tests to date, the system exceeds its design goals with very comfortable margins. It is well advanced into the fabrication stages with all crucial components tested and only straightforward TTL (Transistor Transistor Logic) circuitry to be completed

  9. ATLAS RPC performance on a dedicated cosmic ray test-stand

    International Nuclear Information System (INIS)

    Liberti, B.; Aielli, G.; Camarri, P.; Cardarelli, R.; Corradi, M.; Di Ciaccio, A.; Di Stante, L.; Palummo, L.; Pastori, E.; Salamon, A.; Santonico, R.; Solfaroli, E.

    2008-01-01

    596 RPC chambers have been assembled in the ATLAS Muon Spectrometer, covering a 7300 m 2 sensitive area with 355.000 read out channels. 1116 RPC Units were produced and tested before integration and installation on the experiment [A. Aloisio et al., 'The trigger chambers of the ATLAS muon spectrometer: production and tests', Nuclear Instruments and Methods A535 (2004) 265-271]. 192 ATLAS RPCs, the Barrel Outer Large (BOL) units were tested in INFN Roma Tor Vergata test stand

  10. Make-up of injector test stand (ITS-1) and preliminary results with Model-I ion source

    International Nuclear Information System (INIS)

    Matsuda, S.; Ito, T.; Kondo, U.; Ohara, Y.; Oga, T.; Shibata, T.; Shirakata, H.; Sugawara, T.; Tanaka, S.

    Constitution of the 1-st injector test stand (ITS-1) in the Thermonuclear Division, JAERI, and the performance of the Model-I ion source are described. Heating a plasma by neutral beam injection is one of the promising means in the thermonuclear fusion devices. Purpose of the test stand is to develop the ion sources used in such injection systems. The test stand was completed in February 1975, which is capable of testing the ion sources up to 12 amps at 30 kV. A hydrogen ion beam of 5.5 amps at 25 kV was obtained in the Model-I ion source

  11. Tandem mirror experiment-upgrade neutral beam test stand: a powerful tool for development and quality assurance

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.

    1983-01-01

    During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), we assembled a test stand to develop electronics for the neutral beam system. In the first six months of test stand use we operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, our focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance andd development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises our final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U

  12. Astronaut Ronald Sega with Wake Shield Facility on test stand at JSC

    Science.gov (United States)

    1991-01-01

    The Wake Shield Facility is displayed on a test stand at JSC. Astronaut Ronald M. Sega, mission specialist for STS-60, is seen with the facility during a break in testing in the acoustic and vibration facility at JSC.

  13. Integrated System Health Management: Pilot Operational Implementation in a Rocket Engine Test Stand

    Science.gov (United States)

    Figueroa, Fernando; Schmalzel, John L.; Morris, Jonathan A.; Turowski, Mark P.; Franzl, Richard

    2010-01-01

    This paper describes a credible implementation of integrated system health management (ISHM) capability, as a pilot operational system. Important core elements that make possible fielding and evolution of ISHM capability have been validated in a rocket engine test stand, encompassing all phases of operation: stand-by, pre-test, test, and post-test. The core elements include an architecture (hardware/software) for ISHM, gateways for streaming real-time data from the data acquisition system into the ISHM system, automated configuration management employing transducer electronic data sheets (TEDS?s) adhering to the IEEE 1451.4 Standard for Smart Sensors and Actuators, broadcasting and capture of sensor measurements and health information adhering to the IEEE 1451.1 Standard for Smart Sensors and Actuators, user interfaces for management of redlines/bluelines, and establishment of a health assessment database system (HADS) and browser for extensive post-test analysis. The ISHM system was installed in the Test Control Room, where test operators were exposed to the capability. All functionalities of the pilot implementation were validated during testing and in post-test data streaming through the ISHM system. The implementation enabled significant improvements in awareness about the status of the test stand, and events and their causes/consequences. The architecture and software elements embody a systems engineering, knowledge-based approach; in conjunction with object-oriented environments. These qualities are permitting systematic augmentation of the capability and scaling to encompass other subsystems.

  14. Design of a quadrotor flight test stand for system identification

    CSIR Research Space (South Africa)

    Beharie, MM

    2015-01-01

    Full Text Available This paper presents the design, development and construction of a flight test stand for a quadrotor UAV. As opposed to alternate forms of UAV, the power plant in the case of the quadrotor serves a dual purpose of control and propulsion. Since...

  15. Z-2 Suit Support Stand and MKIII Suit Center of Gravity Test

    Science.gov (United States)

    Nguyen, Tuan Q.

    2014-01-01

    NASA's next generation spacesuits are the Z-Series suits, made for a range of possible exploration missions in the near future. The prototype Z-1 suit has been developed and assembled to incorporate new technologies that has never been utilized before in the Apollo suits and the Extravehicular Mobility Unit (EMU). NASA engineers tested the Z-1 suit extensively in order to developed design requirements for the new Z-2 suit. At the end of 2014, NASA will be receiving the new Z-2 suit to perform more testing and to further develop the new technologies of the suit. In order to do so, a suit support stand will be designed and fabricated to support the Z-2 suit during maintenance, sizing, and structural leakage testing. The Z-2 Suit Support Stand (Z2SSS) will be utilized for these purposes in the early testing stages of the Z-2 suit.

  16. Cryogenic System for the Cryomodule Test Stand at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    White, Michael J. [Fermilab; Hansen, Benjamin [Fermilab; Klebaner, Arkadiy [Fermilab

    2017-10-09

    This paper describes the cryogenic system for the Cryomodule Test Stand (CMTS) at the new Cryomodule Test Facility (CMTF) located at Fermilab. CMTS is designed for production testing of the 1.3 GHz and 3.9GHz cryomodules to be used in the Linac Coherent Light Source II (LCLSII), which is an upgrade to an existing accelerator at Stanford Linear Accelerator Laboratory (SLAC). This paper will focus on the cryogenic system that extends from the helium refrigeration plant to the CMTS cave. Topics covered will include component design, installation and commissioning progress, and operational plans. The paper will conclude with a description of the heat load measurement plan.

  17. Beam-Plasma Interaction Experiments on the Princeton Advanced Test Stand

    Science.gov (United States)

    Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I. D.; Davidson, R. C.

    2011-10-01

    The Princeton Advanced Test Stand (PATS) is a compact experimental facility for studying the fundamental physics of intense beam-plasma interactions relevant to the Neutralized Drift Compression Experiment - II (NDCX-II). The PATS facility consists of a 100 keV ion beam source mounted on a six-foot-long vacuum chamber with numerous ports for diagnostic access. A 100 keV Ar+ beam is launched into a volumetric plasma, which is produced by a ferroelectric plasma source (FEPS). Beam diagnostics upstream and downstream of the FEPS allow for detailed studies of the effects that the plasma has on the beam. This setup is designed for studying the dependence of charge and current neutralization and beam emittance growth on the beam and plasma parameters. This work reports initial measurements of beam quality produced by the extraction electrodes that were recently installed on the PATS device. The transverse beam phase space is measured with double-slit emittance scanners, and the experimental results are compared to WARP simulations of the extraction system. This research is supported by the U.S. Department of Energy.

  18. Saturn V First Stage Leaves the Dynamic Test Stand

    Science.gov (United States)

    1967-01-01

    This photo shows the Saturn V first stage being lowered to the ground following a successful test to determine the effects of continual vibrations simulating the effects of an actual launch. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  19. Introducing sit-stand desks increases classroom standing time among university students

    Directory of Open Access Journals (Sweden)

    Matthew Jerome

    2017-12-01

    Full Text Available Excessive sedentary behavior has been associated with many negative health outcomes. While an understudied health topic, there is evidence that university students are excessively sedentary. Sit-stand desks have been shown to reduce sedentary time among pre-university students (ages 5–18years and sedentary workers but have not been tested in university classrooms. This study tested the effects of introducing sit-stand desks into a university classroom on student's classroom sitting and standing behaviors. Using a cross-over design, students received access to both traditional seated desks and sit-stand desks for six weeks. Data were collected between September and December, 2016. We recruited 304 healthy undergraduate university students enrolled in one of two small (25 seats classrooms at a large Midwestern university during the fall of 2016. Average minutes of standing/hour/student, average percent class time spent standing, and the number of sit-stand transitions/student/hour were directly observed with video camera surveillance. Participants stood significantly more (p<0.001 when provided access to sit-stand desks (7.2min/h/student; 9.3% of class time spent standing compared to when they had access to seated desks (0.7min/h/student; 1.6% of class time spent standing but no differences were observed for the number of sit-stand transitions (p=0.47. Students reported high favorability for the sit-stand desks and improvements in several student engagement and affective outcomes while using the sit-stand desks. These findings support introducing sit-stand desks in university classrooms as an approach to reduce sedentary behaviors of university students. Keywords: Sedentary, University students, Sit-stand desk

  20. A New 500-kV Ion Source Test Stand for HIF

    International Nuclear Information System (INIS)

    Sangster, T.C.; Ahle, L.E.; Halaxa, E.F.; Karpenko, V.P.; Oldaker, M. E.; Mitchell, J.W.; Beck, D.N.; Bieniosek, F.M.; Henestroza, E.; Kwan, J.W.

    2000-01-01

    One of the most challenging aspects of ion beam driven inertial fusion energy is the reliable and efficient generation of low emittance, high current ion beams. The primary ion source requirements include a rise time of order 1-msec, a pulse width of at least 20-msec, a flattop ripple of less than 0.1% and a repetition rate of at least 5-Hz. Naturally, at such a repetition rate, the duty cycle of the source must be greater than 108 pulses. Although these specifications do not appear to exceed the state-of-the-art for pulsed power, considerable effort remains to develop a suitable high current ion source. Therefore, we are constructing a 500-kV test stand specifically for studying various ion source concepts including surface, plasma and metal vapor arc. This paper will describe the test stand design specifications as well as the details of the various subsystems and components

  1. Introducing sit-stand desks increases classroom standing time among university students.

    Science.gov (United States)

    Jerome, Matthew; Janz, Kathleen F; Baquero, Barbara; Carr, Lucas J

    2017-12-01

    Excessive sedentary behavior has been associated with many negative health outcomes. While an understudied health topic, there is evidence that university students are excessively sedentary. Sit-stand desks have been shown to reduce sedentary time among pre-university students (ages 5-18 years) and sedentary workers but have not been tested in university classrooms. This study tested the effects of introducing sit-stand desks into a university classroom on student's classroom sitting and standing behaviors. Using a cross-over design, students received access to both traditional seated desks and sit-stand desks for six weeks. Data were collected between September and December, 2016. We recruited 304 healthy undergraduate university students enrolled in one of two small (25 seats) classrooms at a large Midwestern university during the fall of 2016. Average minutes of standing/hour/student, average percent class time spent standing, and the number of sit-stand transitions/student/hour were directly observed with video camera surveillance. Participants stood significantly more (p classrooms as an approach to reduce sedentary behaviors of university students.

  2. Guidance on the Stand Down, Mothball, and Reactivation of Ground Test Facilities

    Science.gov (United States)

    Volkman, Gregrey T.; Dunn, Steven C.

    2013-01-01

    The development of aerospace and aeronautics products typically requires three distinct types of testing resources across research, development, test, and evaluation: experimental ground testing, computational "testing" and development, and flight testing. Over the last twenty plus years, computational methods have replaced some physical experiments and this trend is continuing. The result is decreased utilization of ground test capabilities and, along with market forces, industry consolidation, and other factors, has resulted in the stand down and oftentimes closure of many ground test facilities. Ground test capabilities are (and very likely will continue to be for many years) required to verify computational results and to provide information for regimes where computational methods remain immature. Ground test capabilities are very costly to build and to maintain, so once constructed and operational it may be desirable to retain access to those capabilities even if not currently needed. One means of doing this while reducing ongoing sustainment costs is to stand down the facility into a "mothball" status - keeping it alive to bring it back when needed. Both NASA and the US Department of Defense have policies to accomplish the mothball of a facility, but with little detail. This paper offers a generic process to follow that can be tailored based on the needs of the owner and the applicable facility.

  3. Mechanical Design, Simulation, and Testing of Self-Aligning Gaussian Telescope and Stand for ITER LFS Reflectometer Diagnostic

    Science.gov (United States)

    Broughton, Rachel; Gomez, Michael; Zolfaghari, Ali; Morris, Lewis

    2016-10-01

    A self-aligning Gaussian telescope has been designed to compensate for the effect of movement in the ITER vacuum vessel on the transmission line. The purpose of the setup is to couple microwaves into and out of the vessel across the vacuum windows while allowing for both slow movements of the vessel, due to thermal growth, and rapid movements, due to vibrations and disruptions. Additionally, a test stand has been designed specifically to hold this telescope in order to imitate these movements. Consequently, this will allow for the assessment of the efficacy in applying the self-aligning Gaussian telescope approach. The motions of the test stand, as well as the stress on the telescope mechanism, have been virtually simulated using ANSYS workbench. A prototype of this test stand and self-aligning telescope will be built using a combination of custom machined parts and ordered parts. The completed mechanism will be tested at the lab in four different ways: slow single- and multi-direction movements, rapid multi-direction movement, functional laser alignment and self-aligning tests, and natural frequency tests. Once the prototype successfully passes all requirements, it will be tested with microwaves in the LFSR transmission line test stand at General Atomics. This work is supported by US DOE Contract No. DE-AC02-09CH11466.

  4. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain: What are the Clinical Implications of Pain During Testing?

    Science.gov (United States)

    Rafn, Bolette S; Tang, Lars; Nielsen, Martin P; Branci, Sonia; Hölmich, Per; Thorborg, Kristian

    2016-05-01

    To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. Cross-sectional study. Clinical assessments at Sports Orthopaedic Research Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. Twenty-four male soccer players with unilateral long-standing hip and groin pain. The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). In 4 tests (isometric hip adduction, abduction, flexion, and eccentric adduction), no significant correlations were found between pain during testing and hip muscle strength (Spearman rho = -0.28 to 0.06, P = 0.09-0.39). Isometric hip flexion (modified Thomas test position) showed a moderate negative correlation between pain and hip muscle strength (Spearman rho = -0.44, P = 0.016). Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain.

  5. Measurement by a cylinder test stand and tyre rolling resistance

    Directory of Open Access Journals (Sweden)

    A. Dávid

    2006-03-01

    Full Text Available Sometimes it is necessary to test how repair affects the properties of the car. These tests are carried out using a cylinder test stand. During the test the tyre is rolling between two cylinders of a small diameter. The question arises whether the rolling resistance of the tyre is the same as the rolling resistance when the wheel is rolling on the plane. If it is not the same what is the reliation between tyre resistances in these two cases? It is an important answer because the change of rolling resistance can affect consumption, the highest speed, engine power and other results of measurement. The paper gives the answer to these questions and describes the method of getting this information.

  6. Brookhaven National Laboratory electron beam test stand

    International Nuclear Information System (INIS)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Prelec, K.; Snydstrup, L.

    1998-01-01

    The main purpose of the electron beam test stand (EBTS) project at the Brookhaven National Laboratory is to build a versatile device to develop technologies that are relevant for a high intensity electron beam ion source (EBIS) and to study the physics of ion confinement in a trap. The EBTS will have all the main attributes of EBIS: a 1-m-long, 5 T superconducting solenoid, electron gun, drift tube structure, electron collector, vacuum system, ion injection system, appropriate control, and instrumentation. Therefore it can be considered a short prototype of an EBIS for a relativistic heavy ion collider. The drift tube structure will be mounted in a vacuum tube inside a open-quotes warmclose quotes bore of a superconducting solenoid, it will be at room temperature, and its design will employ ultrahigh vacuum technology to reach the 10 -10 Torr level. The first gun to be tested will be a 10 A electron gun with high emission density and magnetic compression of the electron beam. copyright 1998 American Institute of Physics

  7. Design of The Test Stand for Hydraulic Active Heave Compensation System

    Directory of Open Access Journals (Sweden)

    Jakubowski Arkadiusz

    2017-01-01

    Full Text Available The article presented here described the design of a test stand for hydraulic active heave compensation system. The simulation of sea waves is realized by the use of hydraulic cylinder. A hydraulic motor is used for sea waves compensation. The hydraulic cylinder and the hydraulic motor are controlled by electrohydraulic servo valves. For the measurements Authors used displacement sensor and incremental encoder. Control algorithm is implemented on the PLC. The performed tests included hydraulic actuator and hydraulic motor step responses.

  8. THE COMPLEX OF STANDS FOR TESTING THE AIR CUSHION CHASSIS OF AIRCRAFT AND VEHICLES

    Directory of Open Access Journals (Sweden)

    2016-01-01

    Full Text Available This article deals with a set of stands made in NIMK TSAGI for testing and creating the air cushion chassis for the aircraft and vehicles. It allows to fully embrace the process of developing and constructing the air cushion chassis for air- craft and solve problems relating to peculiarities of such aircraft on the takeoff, landing and movement in the elementary prepared and unprepared soil runways, flat terrain and water areas. The complex includes: the experimental installation to study aeroelasticity phenomena of the chassis in the extending and retracting process with simulation of aircraft and ekran- oplane takeoff and landing modes in the air flow, including the wind tunnels; the experimental stand with vertical screen for testing of ekranoplane models in T-5 wind tunnel of NIMC TsAGI, permitting to simultaneously vary the model’s posi- tion relatively to the screen, roll, pitch (angle of attack, and banking; mobile experimental stand with contact crawler gear, for experimental determination and comparative evaluation of the chassis with different patterns of formation and air cush- ion fences for all-year-round testing in natural conditions at elementary-prepared and unprepared sites and water areas. Based on mathematical simulation of flow past in the wind tunnel the possibility of use booth stand with vertical screen and experimental installation to study aeroelasticity phenomena of the chassis for experimental studies, respectively, by defini- tion of the aerodynamic characteristics of forces and moments of the air cushion aircraft and ekranoplanes models and the research of phenomena of aeroelasticity of flexible fencing is substantiated.

  9. Cryomdoule Test Stand Reduced-Magnetic Support Design at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    McGee, Mike [Fermilab; Chandrasekaran, Saravan Kumar [Fermilab; Crawford, Anthony [Fermilab; Harms, Elvin [Fermilab; Leibfritz, Jerry [Fermilab; Wu, Genfa [Fermilab

    2016-06-01

    In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be tested at Fermilab's Cryomodule Test Facility (CMTF) within the Cryomodule Test Stand (CMTS-1) cave. The problem of magnetic pollution became one of major issues during design stage of the LCLS-II cryomodule as the average quality factor of the accelerating cavities is specified to be 2.7 x 10¹⁰. One of the possible ways to mitigate the effect of stray magnetic fields and to keep it below the goal of 5 mGauss involves the application of low permeable materials. Initial permeability and magnetic measurement studies regarding the use of 316L stainless steel material indicated that cold work (machining) and heat affected zones from welding would be acceptable.

  10. STATUS OF X-BAND STANDING WAVE STRUCTURE STUDIES AT SLAC

    International Nuclear Information System (INIS)

    Dolgashev, Valery A.

    2003-01-01

    The linacs proposed for the Next Linear Collider (NLC) and Japanese Linear Collider (JLC) would contain several thousand X-Band accelerator structures that would operate at a loaded gradient of 50 MV/m. An extensive experimental and theoretical program is underway at SLAC, FNAL and KEK to develop structures that reliably operate at this gradient. The development of standing wave structures is a part of this program. The properties of standing wave structures allow them to operate at the loaded gradient in contrast to traveling wave structures that need conditioning to the unloaded gradient (65 MV/m for NLC/JLC). The gradients in the standing structures tested thus far have been limited by input coupler breakdowns. The behavior of these breakdowns is consistent with a model of pulsed heating due to high magnetic fields. New input couplers have been designed to reduce maximum magnetic fields. This paper discusses design considerations related to high power performance, wakefield suppression and results of high power tests of prototype standing wave structures

  11. The standing of the curriculum for consumer studies as school ...

    African Journals Online (AJOL)

    ... systems that consistently perform well in international benchmarking tests. The findings of the research point to the standing of the current Consumer Studies curriculum and its perceived impact in the South African context. Recommendations are made regarding the strengthening of the curriculum and its implementation.

  12. Characterizing the Performance of the Princeton Advanced Test Stand Ion Source

    Science.gov (United States)

    Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I.; Davidson, R. C.

    2012-10-01

    The Princeton Advanced Test Stand (PATS) is a compact experimental facility for studying the physics of intense beam-plasma interactions relevant to the Neutralized Drift Compression Experiment - II (NDCX-II). The PATS facility consists of a multicusp RF ion source mounted on a 2 m-long vacuum chamber with numerous ports for diagnostic access. Ar+ beams are extracted from the source plasma with three-electrode (accel-decel) extraction optics. The RF power and extraction voltage (30 - 100 kV) are pulsed to produce 100 μsec duration beams at 0.5 Hz with excellent shot-to-shot repeatability. Diagnostics include Faraday cups, a double-slit emittance scanner, and scintillator imaging. This work reports measurements of beam parameters for a range of beam energies (30 - 50 keV) and currents to characterize the behavior of the ion source and extraction optics. Emittance scanner data is used to calculate the beam trace-space distribution and corresponding transverse emittance. If the plasma density is changing during a beam pulse, time-resolved emittance scanner data has been taken to study the corresponding evolution of the beam trace-space distribution.

  13. Modeling and Testing Legacy Data Consistency Requirements

    DEFF Research Database (Denmark)

    Nytun, J. P.; Jensen, Christian Søndergaard

    2003-01-01

    An increasing number of data sources are available on the Internet, many of which offer semantically overlapping data, but based on different schemas, or models. While it is often of interest to integrate such data sources, the lack of consistency among them makes this integration difficult....... This paper addresses the need for new techniques that enable the modeling and consistency checking for legacy data sources. Specifically, the paper contributes to the development of a framework that enables consistency testing of data coming from different types of data sources. The vehicle is UML and its...... accompanying XMI. The paper presents techniques for modeling consistency requirements using OCL and other UML modeling elements: it studies how models that describe the required consistencies among instances of legacy models can be designed in standard UML tools that support XMI. The paper also considers...

  14. Falls classification using tri-axial accelerometers during the five-times-sit-to-stand test.

    Science.gov (United States)

    Doheny, Emer P; Walsh, Cathal; Foran, Timothy; Greene, Barry R; Fan, Chie Wei; Cunningham, Clodagh; Kenny, Rose Anne

    2013-09-01

    The five-times-sit-to-stand test (FTSS) is an established assessment of lower limb strength, balance dysfunction and falls risk. Clinically, the time taken to complete the task is recorded with longer times indicating increased falls risk. Quantifying the movement using tri-axial accelerometers may provide a more objective and potentially more accurate falls risk estimate. 39 older adults, 19 with a history of falls, performed four repetitions of the FTSS in their homes. A tri-axial accelerometer was attached to the lateral thigh and used to identify each sit-stand-sit phase and sit-stand and stand-sit transitions. A second tri-axial accelerometer, attached to the sternum, captured torso acceleration. The mean and variation of the root-mean-squared amplitude, jerk and spectral edge frequency of the acceleration during each section of the assessment were examined. The test-retest reliability of each feature was examined using intra-class correlation analysis, ICC(2,k). A model was developed to classify participants according to falls status. Only features with ICC>0.7 were considered during feature selection. Sequential forward feature selection within leave-one-out cross-validation resulted in a model including four reliable accelerometer-derived features, providing 74.4% classification accuracy, 80.0% specificity and 68.7% sensitivity. An alternative model using FTSS time alone resulted in significantly reduced classification performance. Results suggest that the described methodology could provide a robust and accurate falls risk assessment. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. INTRODUCING NOVEL GENERATION OF HIGH ACCURACY CAMERA OPTICAL-TESTING AND CALIBRATION TEST-STANDS FEASIBLE FOR SERIES PRODUCTION OF CAMERAS

    Directory of Open Access Journals (Sweden)

    M. Nekouei Shahraki

    2015-12-01

    Full Text Available The recent advances in the field of computer-vision have opened the doors of many opportunities for taking advantage of these techniques and technologies in many fields and applications. Having a high demand for these systems in today and future vehicles implies a high production volume of video cameras. The above criterions imply that it is critical to design test systems which deliver fast and accurate calibration and optical-testing capabilities. In this paper we introduce new generation of test-stands delivering high calibration quality in single-shot calibration of fisheye surround-view cameras. This incorporates important geometric features from bundle-block calibration, delivers very high (sub-pixel calibration accuracy, makes possible a very fast calibration procedure (few seconds, and realizes autonomous calibration via machines. We have used the geometrical shape of a Spherical Helix (Type: 3D Spherical Spiral with special geometrical characteristics, having a uniform radius which corresponds to the uniform motion. This geometrical feature was mechanically realized using three dimensional truncated icosahedrons which practically allow the implementation of a spherical helix on multiple surfaces. Furthermore the test-stand enables us to perform many other important optical tests such as stray-light testing, enabling us to evaluate the certain qualities of the camera optical module.

  16. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Mirarchi, D.; Redaelli, S.; Scandale, W. [CERN, European Organization for Nuclear Research, Geneva 23 (Switzerland); Hall, G. [Imperial College, Blackett Laboratory, London (United Kingdom)

    2017-06-15

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going. (orig.)

  17. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    International Nuclear Information System (INIS)

    Mirarchi, D.; Redaelli, S.; Scandale, W.; Hall, G.

    2017-01-01

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going. (orig.)

  18. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    Science.gov (United States)

    Mirarchi, D.; Hall, G.; Redaelli, S.; Scandale, W.

    2017-06-01

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going.

  19. The stripping foil test stand in the Linac4 transfer line

    CERN Document Server

    Weterings, W; Noulibos, R; Sillanoli, Y; van Trappen, P

    2015-01-01

    The 160 MeV H− beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H− charge-exchange injection system. It will include a stripping foil, to convert H− into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters.

  20. The stripping foil test stand in the Linac4 transfer line

    International Nuclear Information System (INIS)

    Weterings, W.; Bracco, C.; Noulibos, R.; Sillanoli, Y.; Trappen van, P.

    2015-01-01

    The 160 MeV H - beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H - charge-exchange injection system. It will include a stripping foil, to convert H - into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters. (author)

  1. Electronics system for the 150 kV negative ion test stand at BNL

    International Nuclear Information System (INIS)

    Larson, R.A.

    1977-01-01

    The 150 kV test stand at BNL is being used to investigate the extraction, acceleration and transport problems associated with the development of intense negative ion beams. The power supplies associated with these functions as well as the control and monitoring electronics are described

  2. Optimization of a readout board for mass assembly and light yield measurements with a cosmic ray test stand

    Energy Technology Data Exchange (ETDEWEB)

    Chau, Phi [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik (Germany); Collaboration: CALICE-D-Collaboration

    2016-07-01

    We have built a readout board prototype, equipped with SiPMs, scintillators and readout electronics for an highly granular calorimeter. The design was optimized for mass assembly due to about 8 million channels in the final detector. The prototype showed good performance in several test beams and in a cosmic ray test stand, which was built to characterize the MIP response of these kinds of boards. We show an overview of the cosmic ray test stand and measurement results for the readout board and plans for an improved 2nd generation prototype.

  3. Use of a unipedal standing test to assess the ambulation reacquisition time during the early postoperative stage after hip fracture in elderly Japanese: prospective study.

    Science.gov (United States)

    Murata, Koichi; Sugitani, Shigeki; Yoshioka, Hiroki; Noguchi, Takashi; Aoto, Toshiyuki; Nakamura, Takashi

    2010-01-01

    The aim of this study was to predict the ambulation reacquisition time after hip fracture in elderly people using the unipedal standing test during the early postoperative stage. Patients with an intertrochanteric fracture treated with internal fixation (n = 35) and patients with a femoral neck fracture treated with hemiarthroplasty (n = 22) were included. A unipedal standing test using the nonoperated leg was performed on days 3 and 7 after the operation. Among the patients with an intertrochanteric fracture, those with a positive result on the unipedal standing test on postoperative day (POD) 3 attained gait with parallel guide bars (BG) and walker-assisted gait (WG) significantly earlier than did patients with a negative result on the unipedal standing test. Patients with a positive result on the unipedal standing test on POD 7 attained BG, WG, and cane-assisted gait (CG) significantly earlier than did patients with a negative test. Among patients with a femoral neck fracture, those with a positive unipedal standing test result on POD 3 attained BG, WG, and CG significantly earlier than did patients with a negative test. Those with a positive test result on POD 7 attained BG, WG, and CG significantly earlier than did patients with a negative test. The unipedal standing test given during the early postoperative stage is a good test for predicting the ambulation reacquisition time. Moreover, it gives information that can help determine the need for subacute rehabilitation and about discharge planning and health service provision.

  4. Development and field test of psychophysical tests for DWI arrest

    Science.gov (United States)

    1981-03-01

    Administration and scoring procedures were standardized for a sobriety test battery consisting of the walk-and-turn test, the one leg stand test, and horizontal gaze nystagmus. The effectiveness of the standardized battery was then evaluated in the l...

  5. How well does the 30-second Chair Stand Test predict rehabilitation needs?

    DEFF Research Database (Denmark)

    Hansen Bruun, Inge; Nørgaard, Birgitte; Backer Mogensen, Christian

    of functional decline. The 30-Second Chair Stand Test (30s-CST) is recommended by the Danish Health and Medicines Authority for screening of functional decline in elderly citizens living in their own home. However, its validity with hospitalized patients is undocumented, and it is unclear whether loss...... performance, e) patient-related data. Both patients and health professionals will contribute to the face validity assessment. Results The results will be available by the end of 2014. Conclusions Face validations of 30s-CST and DEMMI are relevant as validated tests for short-term hospitalized patients...

  6. A Bayesian Decision-Theoretic Approach to Logically-Consistent Hypothesis Testing

    Directory of Open Access Journals (Sweden)

    Gustavo Miranda da Silva

    2015-09-01

    Full Text Available This work addresses an important issue regarding the performance of simultaneous test procedures: the construction of multiple tests that at the same time are optimal from a statistical perspective and that also yield logically-consistent results that are easy to communicate to practitioners of statistical methods. For instance, if hypothesis A implies hypothesis B, is it possible to create optimal testing procedures that reject A whenever they reject B? Unfortunately, several standard testing procedures fail in having such logical consistency. Although this has been deeply investigated under a frequentist perspective, the literature lacks analyses under a Bayesian paradigm. In this work, we contribute to the discussion by investigating three rational relationships under a Bayesian decision-theoretic standpoint: coherence, invertibility and union consonance. We characterize and illustrate through simple examples optimal Bayes tests that fulfill each of these requisites separately. We also explore how far one can go by putting these requirements together. We show that although fairly intuitive tests satisfy both coherence and invertibility, no Bayesian testing scheme meets the desiderata as a whole, strengthening the understanding that logical consistency cannot be combined with statistical optimality in general. Finally, we associate Bayesian hypothesis testing with Bayes point estimation procedures. We prove the performance of logically-consistent hypothesis testing by means of a Bayes point estimator to be optimal only under very restrictive conditions.

  7. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable...... with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91. Conclusions: The One Leg Stand Test can be used to test postural balance...

  8. Stand diameter distribution modelling and prediction based on Richards function.

    Directory of Open Access Journals (Sweden)

    Ai-guo Duan

    Full Text Available The objective of this study was to introduce application of the Richards equation on modelling and prediction of stand diameter distribution. The long-term repeated measurement data sets, consisted of 309 diameter frequency distributions from Chinese fir (Cunninghamia lanceolata plantations in the southern China, were used. Also, 150 stands were used as fitting data, the other 159 stands were used for testing. Nonlinear regression method (NRM or maximum likelihood estimates method (MLEM were applied to estimate the parameters of models, and the parameter prediction method (PPM and parameter recovery method (PRM were used to predict the diameter distributions of unknown stands. Four main conclusions were obtained: (1 R distribution presented a more accurate simulation than three-parametric Weibull function; (2 the parameters p, q and r of R distribution proved to be its scale, location and shape parameters, and have a deep relationship with stand characteristics, which means the parameters of R distribution have good theoretical interpretation; (3 the ordinate of inflection point of R distribution has significant relativity with its skewness and kurtosis, and the fitted main distribution range for the cumulative diameter distribution of Chinese fir plantations was 0.4∼0.6; (4 the goodness-of-fit test showed diameter distributions of unknown stands can be well estimated by applying R distribution based on PRM or the combination of PPM and PRM under the condition that only quadratic mean DBH or plus stand age are known, and the non-rejection rates were near 80%, which are higher than the 72.33% non-rejection rate of three-parametric Weibull function based on the combination of PPM and PRM.

  9. First environmental data from the EUV engineering test stand

    Science.gov (United States)

    Klebanoff, Leonard E.; Malinowski, Michael E.; Grunow, Philip A.; Clift, W. Miles; Steinhaus, Chip; Leung, Alvin H.; Haney, Steven J.

    2001-08-01

    The first environmental data from the Engineering Test Stand (ETS) has been collected. Excellent control of high-mass hydrocarbons has been observed. This control is a result of extensive outgas testing of components and materials, vacuum compatible design of the ETS, careful cleaning of parts and pre-baking of cables and sub assemblies where possible, and clean assembly procedures. As a result of the hydrocarbon control, the residual ETS vacuum environment is rich in water vapor. Analysis of witness plate data indicates that the ETS environment does not pose a contamination risk to the optics in the absence of EUV irradiation. However, with EUV exposure, the water rich environment can lead to EUV- induced water oxidation of the Si-terminated Mo/Si optics. Added ethanol can prevent optic oxidation, allowing carbon growth via EUV cracking of low-level residual hydrocarbons to occur. The EUV environmental issues are understood, mitigation approaches have been validated, and EUV optic contamination appears to be manageable.

  10. Fall risk screening in the elderly: A comparison of the minimal chair height standing ability test and 5-repetition sit-to-stand test.

    Science.gov (United States)

    Reider, Nadia; Gaul, Catherine

    2016-01-01

    Successfully identifying older adults with a high risk of falling can be complicated, time consuming and not feasible in daily medical practice. This study compared the effectiveness of the Minimal Chair Height Standing Ability Test (MCHSAT) and 5-repetition sit-to-stand tst (5R-STS) as fall risk-screening instruments for the elderly. 167 community-dwelling older adults (mean age=83.6±7.3years) were interviewed for demographics, fall history, cognition, and mobility status. MCHSAT performance was assessed using a chair whose seat height was modifiable by increments of 5cm, starting at 47cm and lowering after each successful attempt. 5R-STS performance was assessed by recording the time it took to rise and sit back down five consecutive times from a chair of 47cm high. Operating Receiving Characteristic (ROC) curves and Area under the Curve (AUC) were calculated for each test as well as for sub-groups of participants classified based on medical comorbidities (e.g. cardiac disease/stroke, lower limb arthritis). The MCHSAT and 5R-STS were equally effective fall-risk screening instruments for the overall population (AUC (95% CI)=0.72 (0.63-0.82) and 0.73(0.64-0.81) respectively). The 5R-STS was more effective than the MCHSAT for participants suffering from lower limb arthritis (AUC (95% CI)=0.81(0.70-0.92) and 0.71(0.58-0.85) respectively) while the opposite was true for participants with a history of cardiac disease or stroke (AUC (95% CI)=0.59 (0.44-0.80) and 0.65 (0.47-0.84) respectively). Due to their simplicity and quick administration time, the MCHSAT and 5R-STS are equally suitable for implementation in clinical settings. Copyright © 2016. Published by Elsevier Ireland Ltd.

  11. Cosmological consistency tests of gravity theory and cosmic acceleration

    Science.gov (United States)

    Ishak-Boushaki, Mustapha B.

    2017-01-01

    Testing general relativity at cosmological scales and probing the cause of cosmic acceleration are among the important objectives targeted by incoming and future astronomical surveys and experiments. I present our recent results on consistency tests that can provide insights about the underlying gravity theory and cosmic acceleration using cosmological data sets. We use statistical measures, the rate of cosmic expansion, the growth rate of large scale structure, and the physical consistency of these probes with one another.

  12. Potential application of the consistency approach for vaccine potency testing.

    Science.gov (United States)

    Arciniega, J; Sirota, L A

    2012-01-01

    The Consistency Approach offers the possibility of reducing the number of animals used for a potency test. However, it is critical to assess the effect that such reduction may have on assay performance. Consistency of production, sometimes referred to as consistency of manufacture or manufacturing, is an old concept implicit in regulation, which aims to ensure the uninterrupted release of safe and effective products. Consistency of manufacture can be described in terms of process capability, or the ability of a process to produce output within specification limits. For example, the standard method for potency testing of inactivated rabies vaccines is a multiple-dilution vaccination challenge test in mice that gives a quantitative, although highly variable estimate. On the other hand, a single-dilution test that does not give a quantitative estimate, but rather shows if the vaccine meets the specification has been proposed. This simplified test can lead to a considerable reduction in the number of animals used. However, traditional indices of process capability assume that the output population (potency values) is normally distributed, which clearly is not the case for the simplified approach. Appropriate computation of capability indices for the latter case will require special statistical considerations.

  13. Test of four stand growth simulators for the northeastern United States

    Science.gov (United States)

    Thomas M. Schuler; David A. Marquis; Richard L. Ernst; Brian T. Simpson; Brian T. Simpson

    1993-01-01

    Evaluates SILVAH, FIBER, NE-TWIGS, and OAKSIM, simulators commonly used in the northeastern United States, by comparing predicted stand development with actual stand development records for periods ranging from 15 to 50 years. Results varied with stand parameter, forest type, projection length, and geographic area. Except in the spruce-fir forest type where FIBER...

  14. An experimental test of the causes of forest growth decline with stand age.

    Science.gov (United States)

    Michael G. Ryan; Dan Binkley; James H. Fownes; Christian Giardina; Randy S. Senock

    2004-01-01

    The decline in aboveground wood production after canopy closure in even-aged forest stands is a common pattern in forests, but clear evidence for the mechanism causing the decline is lacking. The problem is fundamental to forest biology, commercial forestry (the decline sets the rotation age), and to carbon storage in forests. We tested three hypotheses...

  15. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    Science.gov (United States)

    Stasiunas, Eric C.; Parks, Russel A.; Sontag, Brendan D.

    2018-01-01

    A modal test of NASA's Space Launch System (SLS) Core Stage is scheduled to occur at the Stennis Space Center B2 test stand. A derrick crane with a 150-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview and application of the results.

  16. Instrumentation and control system for the AT-2 accelerator test stand

    International Nuclear Information System (INIS)

    Wadlinger, E.A.; Holtkamp, D.B.; Holt, H.D.

    1984-01-01

    A data-driven subroutine package, written for our accelerator test stand (ATS), is described. This flexible package permits the rapid writing and modifying of data acquisition, control, and analysis programs for the many diverse experiments performed on the ATS. These structurally simple and easy to maintain routines help to control administratively the integrity of the ATS through the use of the database. Our operating experience indicates that the original design goals have been met. We describe the subroutines, database, and our experiences with this system

  17. The study of fix composite panel and steel plates on testing stand

    Science.gov (United States)

    Wróbel, A.; Płaczek, M.; Wachna, M.

    2016-08-01

    In this paper the practical possibilities of strength verification analysis of composite materials used in the manufacture of selected components of railway wagons are presented. Real laboratory stand for measurements in a scale controlled by PLC controller were made. The study of different types of connections of composite materials with sheet metal is presented. In one of the chapter of this paper principles construction of testing stand with pneumatic cylinder were presented. Mainly checking of displacements and stresses generated on the sheet as a result of pneumatic actuators load for composite boards was carried out. The use of the controller with operating panel allows to easy programming testing cycle. The user can define the force generated by the actuator by change of air pressure in cylinder. Additionally the location of acting cylinders and their jump can be changed by operator. The examination of the volume displacements was done by displacement sensor, and the tensile strain gauge. All parameters are written in CatmanEasy - data acquisition software. This article presents the study of stresses and displacements in the composite plates joined with sheet metal, in summary of this article, the authors compare the obtained results with the computer simulation results in the article: "Simulation of stresses in an innovative combination of composite with sheet".

  18. Laser based beam diagnostic for the RAL Front End Test Stand (FETS)

    International Nuclear Information System (INIS)

    Gabor, C.; Lee, D. A.; Pozimski, J. K.; Letchford, A.

    2007-01-01

    For the diagnostic of high power particle beams, non-destructive measurement devices provide minimum influence on the beam and avoid various problems in connection with the high power density on surfaces. An H- ion beam offers the opportunity of non destructive beam diagnostics based on the effect of photo detachment. By the interaction of light with H- ions, the additional electron can be detached and a small number of neutrals will be produced. An additional magnetic dipole field can then be used to separate the detached electrons and neutrals from the ions. Using an integral detector the spatial distribution of the beam ion density can be derived, while the use of a spatial resolving detector enables to determine the phase space distribution. To investigate the measurement principle of the latter, a test stand was set up at the IAP in Frankfurt. This system will now be adopted to the requirements of the Front End Test Stand at CCLRC/ RAL. The aim of this FETS is to demonstrate a chopped H- beam of 60mA at 3MeV and 50pps with sufficiently high beam quality. The paper will present a detailed description of the proposed set up at RAL and discuss several results of simulations and experimental data gained in Frankfurt

  19. Measurements of high energy photons in Z-pinch experiments on primary test stand

    International Nuclear Information System (INIS)

    Si, Fenni; Zhang, Chuanfei; Xu, Rongkun; Yuan, Xi; Huang, Zhanchang; Xu, Zeping; Ye, Fan; Yang, Jianlun; Ning, Jiamin; Hu, Qingyuan; Zhu, Xuebin

    2015-01-01

    High energy photons are measured for the first time in wire-array Z-pinch experiments on the Primary Test Stand (PTS) which delivers a current up to 8 MA with a rise time of 70 ns. A special designed detecting system composed of three types of detectors is used to measure the average energy, intensity, and pulse waveform of high energy photons. Results from Pb-TLD (thermoluminescence dosimeter) detector indicate that the average energy is 480 keV (±15%). Pulse shape of high energy photons is measured by the photodiode detector consisted of scintillator coupled with a photodiode, and it is correlated with soft x-ray power by the same timing signal. Intensity is measured by both TLD and the photodiode detector, showing good accordance with each other, and it is 10 10 cm −2 (±20%) at 2 m in the horizontal direction. Measurement results show that high energy photons are mainly produced in pinch regions due to accelerated electrons. PTS itself also produces high energy photons due to power flow electrons, which is one order smaller in amplitude than those from pinch region

  20. Commissioning of the Linac4 RFQ at the 3 MeV test stand

    CERN Document Server

    Rossi, C; Bellodi, G; Broere, J; Brunner, O; Lombardi, A M; Balula, J M; Yanez, P M; Noirjean, J; Pasquino, C; Raich, U; Roncarolo, F; Vretenar, M; Desmons, M; France, A; Piquet, O

    2013-01-01

    Linac4, the future 160 MeV Hˉ injector to the CERN Proton Synchrotron Booster, is presently under construction at CERN as a first step of the planned upgrade of the LHC injectors. The low energy section of LINAC4, consisting of an ion source, a 352.2 MHz Radio Frequency Quadrupole (RFQ) and a chopper line is being commissioned in a dedicated test stand before installation in its final position in the tunnel. The RFQ is designed to accelerate a 45 keV, 70 mA, Hˉ beam to 3 MeV, with an efficiency of 95% while preserving the transverse emittance. The RFQ, a four-vane structure 3 m in length, has been designed in collaboration with CEA/IRFU and is has been fabricated at the CERN workshop. The precise fabrication has allowed achieving a field flatness of 1%. The completion of the accelerating structure in September 2012 was followed by a complete series of bead-pull measurements and by high-power conditioning to the nominal power of 0.39 MW corresponding to a voltage of 78 kV across the 3 meters. Measurements wi...

  1. Standing-up exerciser based on functional electrical stimulation and body weight relief.

    Science.gov (United States)

    Ferrarin, M; Pavan, E E; Spadone, R; Cardini, R; Frigo, C

    2002-05-01

    The goal of the present work was to develop and test an innovative system for the training of paraplegic patients when they are standing up. The system consisted of a computer-controlled stimulator, surface electrodes for quadricep muscle stimulation, two knee angle sensors, a digital proportional-integrative-derivative (PID) controller and a mechanical device to support, partially, the body weight (weight reliever (WR)). A biomechanical model of the combined WR and patient was developed to find an optimum reference trajectory for the PID controller. The system was tested on three paraplegic patients and was shown to be reliable and safe. One patient completed a 30-session training period. Initially he was able to stand up only with 62% body weight relief, whereas, after the training period, he performed a series of 30 standing-up/sitting-down cycles with 45% body weight relief. The closed-loop controller was able to keep the patient standing upright with minimum stimulation current, to compensate automatically for muscle fatigue and to smooth the sitting-down movement. The limitations of the controller in connection with a highly non-linear system are considered.

  2. Radiation measurements during cavities conditioning on APS RF test stand

    International Nuclear Information System (INIS)

    Grudzien, D.M.; Kustom, R.L.; Moe, H.J.; Song, J.J.

    1993-01-01

    In order to determine the shielding structure around the Advanced Photon Source (APS) synchrotron and storage ring RF stations, the X-ray radiation has been measured in the near field and far field regions of the RF cavities during the normal conditioning process. Two cavity types, a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity, are used on the APS and are conditioned in the RF test stand. Vacuum measurements are also taken on a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity. The data will be compared with data on the five-cell cavities from CERN

  3. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    Science.gov (United States)

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  4. Fluorescent screens and image processing for the APS linac test stand

    International Nuclear Information System (INIS)

    Berg, W.; Ko, K.

    1992-01-01

    A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image

  5. Down force calibration stand test report

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    The Down Force Calibration Stand was developed to provide an improved means of calibrating equipment used to apply, display and record Core Sample Truck (CST) down force. Originally, four springs were used in parallel to provide a system of resistance that allowed increasing force over increasing displacement. This spring system, though originally deemed adequate, was eventually found to be unstable laterally. For this reason, it was determined that a new method for resisting down force was needed

  6. Predictive Cutoff Values of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for Disability Incidence in Older People Dwelling in the Community.

    Science.gov (United States)

    Makizako, Hyuma; Shimada, Hiroyuki; Doi, Takehiko; Tsutsumimoto, Kota; Nakakubo, Sho; Hotta, Ryo; Suzuki, Takao

    2017-04-01

    Lower extremity functioning is important for maintaining activity in elderly people. Optimal cutoff points for standard measurements of lower extremity functioning would help identify elderly people who are not disabled but have a high risk of developing disability. The purposes of this study were: (1) to determine the optimal cutoff points of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for predicting the development of disability and (2) to examine the impact of poor performance on both tests on the prediction of the risk of disability in elderly people dwelling in the community. This was a prospective cohort study. A population of 4,335 elderly people dwelling in the community (mean age = 71.7 years; 51.6% women) participated in baseline assessments. Participants were monitored for 2 years for the development of disability. During the 2-year follow-up period, 161 participants (3.7%) developed disability. The optimal cutoff points of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for predicting the development of disability were greater than or equal to 10 seconds and greater than or equal to 9 seconds, respectively. Participants with poor performance on the Five-Times Sit-to-Stand Test (hazard ratio = 1.88; 95% CI = 1.11-3.20), the Timed "Up & Go" Test (hazard ratio = 2.24; 95% CI = 1.42-3.53), or both tests (hazard ratio = 2.78; 95% CI = 1.78-4.33) at the baseline assessment had a significantly higher risk of developing disability than participants who had better lower extremity functioning. All participants had good initial functioning and participated in assessments on their own. Causes of disability were not assessed. Assessments of lower extremity functioning with the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test, especially poor performance on both tests, were good predictors of future disability in elderly people dwelling in the community. © 2017 American Physical Therapy Association

  7. Observation of a H- Beam at the CERN Linac 4 Test Stand using a Pepper-pot

    CERN Document Server

    Delerue, N; Midttun, O; Scrivens, R; Tsesmelis, E

    2010-01-01

    Pepper-pot based transverse emittance measurement has the advantage of providing a fast (single shot) measurement with a relatively simple hardware. We report on the installation of a pepper-pot at the CERN Linac 4 test stand.

  8. Isotope separation by standing waves

    International Nuclear Information System (INIS)

    Altshuler, S.

    1984-01-01

    The separation of isotopes is accomplished by scattering a beam of particles from a standing electromagnetic wave. The particles may consist of either atoms or molecules, the beam having in either case a desired isotope and at least one other. The particle beam is directed so as to impinge on the standing electromagnetic wave, which may be a light wave. The particles, that is, the atomic or molecular quantum-mechanical waves, see basically a diffraction grating corresponding to the troughs and peaks of the electromagnetic wave. The frequency of the standing electromagnetic wave substantially corresponds to an internal energy level-transition of the desired isotope. Accordingly, the desired isotope is spatially separated by being scattered or diffracted. (author)

  9. Personal Hypothesis Testing: The Role of Consistency and Self-Schema.

    Science.gov (United States)

    Strohmer, Douglas C.; And Others

    1988-01-01

    Studied how individuals test hypotheses about themselves. Examined extent to which Snyder's bias toward confirmation persists when negative or nonconsistent personal hypothesis is tested. Found negativity or positivity did not affect hypothesis testing directly, though hypothesis consistency did. Found cognitive schematic variable (vulnerability…

  10. Analysis of tree stand horizontal structure using random point field methods

    Directory of Open Access Journals (Sweden)

    O. P. Sekretenko

    2015-06-01

    Full Text Available This paper uses the model approach to analyze the horizontal structure of forest stands. The main types of models of random point fields and statistical procedures that can be used to analyze spatial patterns of trees of uneven and even-aged stands are described. We show how modern methods of spatial statistics can be used to address one of the objectives of forestry – to clarify the laws of natural thinning of forest stand and the corresponding changes in its spatial structure over time. Studying natural forest thinning, we describe the consecutive stages of modeling: selection of the appropriate parametric model, parameter estimation and generation of point patterns in accordance with the selected model, the selection of statistical functions to describe the horizontal structure of forest stands and testing of statistical hypotheses. We show the possibilities of a specialized software package, spatstat, which is designed to meet the challenges of spatial statistics and provides software support for modern methods of analysis of spatial data. We show that a model of stand thinning that does not consider inter-tree interaction can project the size distribution of the trees properly, but the spatial pattern of the modeled stand is not quite consistent with observed data. Using data of three even-aged pine forest stands of 25, 55, and 90-years old, we demonstrate that the spatial point process models are useful for combining measurements in the forest stands of different ages to study the forest stand natural thinning.

  11. Migraine patients consistently show abnormal vestibular bedside tests.

    Science.gov (United States)

    Maranhão, Eliana Teixeira; Maranhão-Filho, Péricles; Luiz, Ronir Raggio; Vincent, Maurice Borges

    2016-01-01

    Migraine and vertigo are common disorders, with lifetime prevalences of 16% and 7% respectively, and co-morbidity around 3.2%. Vestibular syndromes and dizziness occur more frequently in migraine patients. We investigated bedside clinical signs indicative of vestibular dysfunction in migraineurs. To test the hypothesis that vestibulo-ocular reflex, vestibulo-spinal reflex and fall risk (FR) responses as measured by 14 bedside tests are abnormal in migraineurs without vertigo, as compared with controls. Cross-sectional study including sixty individuals - thirty migraineurs, 25 women, 19-60 y-o; and 30 gender/age healthy paired controls. Migraineurs showed a tendency to perform worse in almost all tests, albeit only the Romberg tandem test was statistically different from controls. A combination of four abnormal tests better discriminated the two groups (93.3% specificity). Migraine patients consistently showed abnormal vestibular bedside tests when compared with controls.

  12. The 1-min sit-to-stand test--A simple functional capacity test in cystic fibrosis?

    Science.gov (United States)

    Radtke, Thomas; Puhan, Milo A; Hebestreit, Helge; Kriemler, Susi

    2016-03-01

    We aimed to assess the measurement properties and the minimal important difference (MID) of the 1-min sit-to-stand (STS) test in cystic fibrosis (CF). Patients with CF were tested during a pulmonary rehabilitation program. Five STS tests were performed during the program; two tests at the beginning (STS0 and STS1) and three tests at the end (STS2a-2c). Exercise capacity, pulmonary function, and health-related quality of life (HRQoL) and patient-reported health status were measured at the beginning and end of the program. We calculated overall mean, standard deviation, coefficient of variation (CV), and intraclass correlation coefficient (ICC) of the STS test. The MID was calculated using anchor-based and distributional methods. Fourteen participants (8 female, mean age 30.4±6.1years) were included. STS test performance increased significantly from STS0 to STS1 indicative of a learning effect. Test-retest reliability for the subsequent STS2a-2c tests was excellent (ICC 0.98, 95% CI 0.96-0.99). The estimated MID for the STS test was 5 repetitions. STS test performance was responsive to change (effect size of 0.97) and correlated with exercise capacity (r=0.63-0.73) and with the physical functioning HRQoL scale (r=0.72). The 1-min STS test appears to be a reliable, valid, and feasible test to measure functional capacity in patients with CF. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  13. Using a stand-level model to predict light absorption in stands with vertically and horizontally heterogeneous canopies

    Directory of Open Access Journals (Sweden)

    David I Forrester

    2014-09-01

    Full Text Available Background Forest ecosystem functioning is strongly influenced by the absorption of photosynthetically active radiation (APAR, and therefore, accurate predictions of APAR are critical for many process-based forest growth models. The Lambert-Beer law can be applied to estimate APAR for simple homogeneous canopies composed of one layer, one species, and no canopy gaps. However, the vertical and horizontal structure of forest canopies is rarely homogeneous. Detailed tree-level models can account for this heterogeneity but these often have high input and computational demands and work on finer temporal and spatial resolutions than required by stand-level growth models. The aim of this study was to test a stand-level light absorption model that can estimate APAR by individual species in mixed-species and multi-layered stands with any degree of canopy openness including open-grown trees to closed canopies. Methods The stand-level model was compared with a detailed tree-level model that has already been tested in mixed-species stands using empirical data. Both models were parameterised for five different forests, including a wide range of species compositions, species proportions, stand densities, crown architectures and canopy structures. Results The stand-level model performed well in all stands except in the stand where extinction coefficients were unusually variable and it appears unlikely that APAR could be predicted in such stands using (tree- or stand-level models that do not allow individuals of a given species to have different extinction coefficients, leaf-area density or analogous parameters. Conclusion This model is parameterised with species-specific information about extinction coefficients and mean crown length, diameter, height and leaf area. It could be used to examine light dynamics in complex canopies and in stand-level growth models.

  14. Development of small C-band standing-wave accelerator structure

    International Nuclear Information System (INIS)

    Miura, S.; Takahashi, A.; Hisanaga, N.; Sekido, H.; Yoshizumi, A.

    2000-01-01

    We have newly developed a compact C-band (5712 MHz) standing-wave accelerator for the medical product/waste sterilization applications. The accelerator consists of an electron gun operating at 25 kV DC followed by a single-cell pre-buncher and 3-cell buncher section, and 11-cell of the side-coupled standing-wave accelerating structure. The total length including the electron gun is about 600 mm. The first high-power test was performed in March 2000, where the accelerator successively generated the electron beam of 9 MeV energy and 160 mA peak-current at 3.8 MW RF input power. Mitsubishi Heavy Industry starts to serve the sterilization systems using C-band accelerator reported here, and also supplies the accelerator components for the medical oncology applications. (author)

  15. JAERI Fuel Cleanup System (J-FCU) stand-alone tritium test at the TSTA

    International Nuclear Information System (INIS)

    Konishi, Satoshi; Hayashi, Takumi; Inoue, Masahiko

    1993-03-01

    JAERI designed, fabricated, and installed the JAERI Fuel Cleanup System (J-FCU) as a subsystem of simulated fusion fuel loop at the TSTA. The main function of the J-FCU is to purify and to recover hydrogen isotopes from simulated plasma exhaust while exhausting tritium free impurities. After a lot of deuterium tests, a first tritium test of the J-FCU was performed with one gram of tritium at the TSTA on June 1991. Main purpose of this test was to evaluate the total integrity and function of the J-FCU system with a DT mixture. Through this test, the J-FCU was operated well and its function with tritium was demonstrated. This report describes the detail test results of the J-FCU first tritium test and discuss its functions by stand-alone mode. Residual tritium inventory of the J-FCU system was also discussed. (author)

  16. F-15B ACTIVE with thrust vectoring nozzles on test stand

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the thrust stand being used for ground testing of a new thrust-vectoring concept involving two new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. These nozzles give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. These tests could lead to significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace.

  17. Migraine patients consistently show abnormal vestibular bedside tests

    Directory of Open Access Journals (Sweden)

    Eliana Teixeira Maranhão

    2015-01-01

    Full Text Available Migraine and vertigo are common disorders, with lifetime prevalences of 16% and 7% respectively, and co-morbidity around 3.2%. Vestibular syndromes and dizziness occur more frequently in migraine patients. We investigated bedside clinical signs indicative of vestibular dysfunction in migraineurs.Objective To test the hypothesis that vestibulo-ocular reflex, vestibulo-spinal reflex and fall risk (FR responses as measured by 14 bedside tests are abnormal in migraineurs without vertigo, as compared with controls.Method Cross-sectional study including sixty individuals – thirty migraineurs, 25 women, 19-60 y-o; and 30 gender/age healthy paired controls.Results Migraineurs showed a tendency to perform worse in almost all tests, albeit only the Romberg tandem test was statistically different from controls. A combination of four abnormal tests better discriminated the two groups (93.3% specificity.Conclusion Migraine patients consistently showed abnormal vestibular bedside tests when compared with controls.

  18. Beam-Based Diagnostics of RF-Breakdown in the Two-Beam Test-Stand in CTF3

    CERN Document Server

    Johnson, M

    2007-01-01

    The general outline of a beam-based diagnostic method of RF-breakdown, using BPMs, at the two-beam test-stand in CTF3 is discussed. The basic components of the set-up and their functions in the diagnostic are described. Estimations of the expected error in the measured parameters are performed.

  19. Short-Cut Estimators of Criterion-Referenced Test Consistency.

    Science.gov (United States)

    Brown, James Dean

    1990-01-01

    Presents simplified methods for deriving estimates of the consistency of criterion-referenced, English-as-a-Second-Language tests, including (1) the threshold loss agreement approach using agreement or kappa coefficients, (2) the squared-error loss agreement approach using the phi(lambda) dependability approach, and (3) the domain score…

  20. Number of test trials needed for performance stability and interrater reliability of the one leg stand test in patients with a major non-traumatic lower limb amputation

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Nielsen, Anni Østergaard; Madsen Topp, Ulla

    2014-01-01

    Balance is beneficial for daily functioning of patients with a lower limb amputation and sometimes assessed by the one-leg stand test (OLST). The aims of the study were to examine (1) the number of trials needed to achieve performance stability, (2) the interrater reliability of the OLST in patie......Balance is beneficial for daily functioning of patients with a lower limb amputation and sometimes assessed by the one-leg stand test (OLST). The aims of the study were to examine (1) the number of trials needed to achieve performance stability, (2) the interrater reliability of the OLST...... in patients with a major non-traumatic lower limb amputation, and (3) to provide a test procedure....

  1. The zero inflation of standing dead tree carbon stocks

    Science.gov (United States)

    Christopher W. Woodall; David W. MacFarlane

    2012-01-01

    Given the importance of standing dead trees in numerous forest ecosystem attributes/processes such as carbon (C) stocks, the USDA Forest Service’s Forest Inventory and Analysis (FIA) program began consistent nationwide sampling of standing dead trees in 1999. Modeled estimates of standing dead tree C stocks are currently used as the official C stock estimates for the...

  2. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Corrective Action Investigation Plan for Corrective Action Unit 252: Area 25 Engine Test Stand 1 Decontamination Pad, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Nevada Operations Office

    1999-08-20

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit 252 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 252 consists of Corrective Action Site (CAS) 25-07-02, Engine Test Stand-1 (ETS-1) Decontamination Pad. Located in Area 25 at the intersection of Road H and Road K at the Nevada Test Site, ETS-1 was designed for use as a mobile radiation checkpoint and for vehicle decontamination. The CAS consists of a concrete decontamination pad with a drain, a gravel-filled sump, two concrete trailer pads, and utility boxes. Constructed in 1966, the ETS-1 facility was part of the Nuclear Rocket Development Station (NRDS) complex and used to test nuclear rockets. The ETS-1 Decontamination Pad and mobile radiation check point was built in 1968. The NRDS complex ceased primary operations in 1973. Based on site history, the focus of the field investigation activities will be to determine if any primary contaminants of potential concern (COPCs) (including radionuclides, total volatile organic compounds, total semivolatile organic compounds, total petroleum hydrocarbons as diesel-range organics, Resource Conservation and Recovery Act metals, total pesticides, and polychlorinated biphenyls) are present at this site. Vertical extent of migration of suspected vehicle decontamination effluent COPCs is expected to be less than 12 feet below ground surface. Lateral extent of migration of COPCs is expected to be limited to the sump area or near the northeast corner of the decontamination pad. Using a biased sampling approach, near-surface and subsurface sampling will be conducted at the suspected worst-case areas including the sump and soil near the northeast corner of the decontamination pad. The results of this field investigation will support a defensible e

  4. Application of an In-Line Contamination Monitoring Unit to the AHT-64 Hydraulic Test Stand.

    Science.gov (United States)

    1981-06-04

    suction return connection port will require the operator to secuire same from a squatting position. The present stowage arrangement on the test stand... SPC FC sample~~~ Iepal" -a *Tpoa _______Rate 7 eo3,t Sq,’ TPc owe te - U Enciosure ULeeds & Northrup N’AFC- 92- 1 0 Typical Plumbing Connections for

  5. Compatible growth models and stand density diagrams

    International Nuclear Information System (INIS)

    Smith, N.J.; Brand, D.G.

    1988-01-01

    This paper discusses a stand average growth model based on the self-thinning rule developed and used to generate stand density diagrams. Procedures involved in testing are described and results are included

  6. Short-term consistency testing vs. long-term behavior

    International Nuclear Information System (INIS)

    Ebert, W.L.; Bakel, A.J.; Wolf, S.F.; Strachan, D.M.

    1997-01-01

    The authors conducted Product Consistency Tests (PCTs) with a surrogate low-activity waste (LAW) glass to (1) evaluate the possible use of various test conditions in a specification test for LAW waste forms, (2) measure the reproducibility of the test at low temperatures, and (3) determine if the rates calculated from 7-day PCTs bound the rates measured in PCT conducted for longer durations, which represent more advanced corrosion. The effects of temperature and pH on the dissolution rate in PCTs are much less than the effects observed in dilute solutions due to the buildup of dissolved glass components in the PCTs. The precision of replicate 7-day tests at 20 and 40 degrees C was limited by the analytical uncertainty. The dissolution rates at all temperatures decreased with the test duration initially. However, the dissolution rates in tests at 70 and 90 degrees C increased when certain alteration phases formed after about 100 and 500 days, respectively; the rates in some tests exceeded that measured in a 7-day PCT. While the 7-day PCT does not provide a bounding rate for this glass at 70 or 90 degrees C, tests for longer durations are needed to determine if a 7-day test provides a bounding rate at lower temperatures

  7. High technology at 'General Turbo', DH 12/13 balance-over speed testing stand

    International Nuclear Information System (INIS)

    Nuta, Florian Nicolae; Vasiliu, Dinu; Mauna, Traian

    2005-01-01

    'General Turbo' activity started in 1970 including building the balancing and over speed stand. DH 12/13 is the latest up-to-date facility of this type, the best one of the five in Europe, and was commissioned in 2004. The facility was especially built to be used for Romanian Nuclear Power Plant rotor testing and also for thermal very big rotors. The paper underlines the main attributes and the components of the facility DH 12/13 based on the Schenck technology. (authors)

  8. DEVELOPMENT OF AN ARMY STATIONARY AXLE TEST STAND FOR LUBRICANT EFFICIENCY EVALUATION-PART II

    Science.gov (United States)

    2017-01-13

    electric AC motor , and the two outputs of the axle are coupled using speed increasing gear boxes and absorbed by an identically sized AC motor ...work using the stationary axle efficiency test stand was completed using hardware representative of light and medium duty tactical wheeled vehicles ... vehicle results. However for the results to be applicable to real world field use , the driving cycle being replicated should be representative of real

  9. Learning to Stand: The Acceptability and Feasibility of Introducing Standing Desks into College Classrooms

    Directory of Open Access Journals (Sweden)

    Roberto M. Benzo

    2016-08-01

    Full Text Available Prolonged sedentary behavior is an independent risk factor for multiple negative health outcomes. Evidence supports introducing standing desks into K-12 classrooms and work settings to reduce sitting time, but no studies have been conducted in the college classroom environment. The present study explored the acceptability and feasibility of introducing standing desks in college classrooms. A total of 993 students and 149 instructors completed a single online needs assessment survey. This cross-sectional study was conducted during the fall semester of 2015 at a large Midwestern University. The large majority of students (95% reported they would prefer the option to stand in class. Most students (82.7% reported they currently sit during their entire class time. Most students (76.6% and instructors (86.6% reported being in favor of introducing standing desks into college classrooms. More than half of students and instructors predicted having access to standing desks in class would improve student’s “physical health”, “attention”, and “restlessness”. Collectively, these findings support the acceptability of introducing standing desks in college classrooms. Future research is needed to test the feasibility, cost-effectiveness and efficacy of introducing standing desks in college classrooms. Such studies would be useful for informing institutional policies regarding classroom designs.

  10. Comparison between Standing Broad Jump test and Wingate test for assessing lower limb anaerobic power in elite sportsmen.

    Science.gov (United States)

    Krishnan, Anup; Sharma, Deep; Bhatt, Madhu; Dixit, Apoorv; Pradeep, P

    2017-04-01

    Lower limb explosive power is an important motor quality for sporting performance and indicates use of anaerobic energy systems like stored ATP and Creatine phosphate system. Weightlifting, Fencing and Wrestling use it for monitoring and identification of potential sportsmen. The Wingate test and Standing Broad Jump (SBJ) test are reliable and accurate tests for its assessment. This study conducted on elite Indian sportsmen tries to analyse feasibility of use of the SBJ test in sports and military medicine when Wingate test is impractical. 95 elite sportsmen (51 Fencers, 17 Weight lifters and 27 Wrestlers) of a sports institute were administered Wingate cycle ergometer test and SBJ under standardised conditions. The results were analysed for mass and inter-discipline correlation. Analysis using Pearson's correlation showed significant positive correlation between Peak power ( r  = 0.446, p  Weightlifters. Bland-Altman plot analysis showed that about 94% pairs of peak power and SBJ were within limits of agreement for each discipline as well as among all sportsmen. The test results show definite correlation and SBJ test can be used as a field test in performance monitoring, talent identification, military recruit screening and injury prevention.

  11. Design, building and testing of a stand alone fuel cell hybrid system

    Energy Technology Data Exchange (ETDEWEB)

    Segura, F.; Duran, E.; Andujar, J.M. [Department of Electronic, Computer Science and Automatic Engineering, University of Huelva (Spain)

    2009-08-01

    This paper designs, sizes, builds and tests a stand alone fuel cell hybrid system made up of a fuel cell stack and a battery bank. This system has been sized to supply a typical telecommunication load profile, but moreover, the system can supply other profiles. For this purpose, a modular low cost electronic load bank has been designed and built. This load bank allows the power demand to be chosen by selecting different solid state relays. Moreover, a virtual instrument based on NI Labview {sup registered} has been designed to select the load power demand from the computer. (author)

  12. Preliminary experimental results of tungsten wire-array Z-pinches on primary test stand

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xian-Bin; Zhou, Shao-Tong; Dan, Jia-Kun; Ren, Xiao-Dong, E-mail: amosrxd@163.com; Wang, Kun-Lun; Zhang, Si-Qun; Li, Jing; Xu, Qiang; Cai, Hong-Chun; Duan, Shu-Chao; Ouyang, Kai; Chen, Guang-Hua; Ji, Ce; Wei, Bing; Feng, Shu-Ping; Wang, Meng; Xie, Wei-Ping; Deng, Jian-Jun [Key Laboratory of Pulsed Power, Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-108, Mianyang, Sichuan 621999 (China); Zhou, Xiu-Wen; Yang, Yi [Research Center of Laser Fusion, China Academy of Engineering Physics, P.O. Box 919-987, Mianyang, Sichuan 621999 (China)

    2015-07-15

    The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a 20 TW pulsed power driver, which can deliver a ∼10 MA, 70 ns rise-time (10%–90%) current to a short-circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. Preliminary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 13 mm to 30 mm, consisting of 132–300 tungsten wires with 5–10 μm in diameter. Multiple diagnostics were fielded to characterize the x-ray radiation from wire-array Z pinches. The x-ray peak power (∼50 TW) and total radiated energy (∼500 kJ) were obtained from a single 20-mm-diam array with 80-ns stagnation time. The highest x-ray peak power up to 80 TW with 2.4 ns FWHM was achieved by using a nested array with 20-mm outer diameter, and the total x-ray energy from the nested array is comparable to that of single array. Implosion velocity estimated from the time-resolved image measurement exceeds 30 cm/μs. The detailed experimental results and other findings are presented and discussed.

  13. Seismic design method of free standing rack

    International Nuclear Information System (INIS)

    Taniguchi, Katsuhiko; Okuno, Daisaku; Iwasaki, Akihisa; Nekomoto, Yoshitsugu; Matsuoka, Toshihiro

    2013-01-01

    For high earthquake resistance and ease of installation, free standing racks which are not anchored to the pool floor or walls has been adopted in many countries. Under the earthquake, the response of the free standing rack is highly nonlinear and involves a complex combination of motions (sliding, rocking, twisting, and turning) and impacts between the fuel assemblies and the fuel cell walls, rack-to-rack, and the pit floor and rack pedestals. We carried out seismic experiments on the full-scale rack model in water and dry conditions to obtain the fundamental data about free standing rack (sliding, rocking and turning motions). We have developed the nonlinear dynamic analysis method to predict seismic response for the free standing rack utilizing the full-scale test result and verified the analysis evaluation method of the rack by comparison of test result. (author)

  14. A Test Stand for Ion Sources of Ultimate Reliability

    International Nuclear Information System (INIS)

    Enparantza, R.; Uriarte, L.; Romano, P.; Alonso, J.; Ariz, I.; Egiraun, M.; Bermejo, F. J.; Etxebarria, V.; Lucas, J.; Del Rio, J. M.; Letchford, A.; Faircloth, D.; Stockli, M.

    2009-01-01

    The rationale behind the ITUR project is to perform a comparison between different kinds of H - ion sources using the same beam diagnostics setup. In particular, a direct comparison will be made in terms of the emittance characteristics of Penning Type sources such as those currently in use in the injector for the ISIS (UK) Pulsed Neutron Source and those of volumetric type such as that driving the injector for the ORNL Spallation Neutron Source (TN, U.S.A.). The endeavour here pursued is thus to build an Ion Source Test Stand where virtually any type of source can be tested and its features measured and, thus compared to the results of other sources under the same gauge. It would be possible then to establish a common ground for effectively comparing different ion sources. The long term objectives are thus to contribute towards building compact sources of minimum emittance, maximum performance, high reliability-availability, high percentage of desired particle production, stability and high brightness. The project consortium is lead by Tekniker-IK4 research centre and partners are companies Elytt Energy and Jema Group. The technical viability is guaranteed by the collaboration between the project consortium and several scientific institutions, such the CSIC (Spain), the University of the Basque Country (Spain), ISIS (STFC-UK), SNS (ORNL-USA) and CEA in Saclay (France).

  15. Integrated System Health Management (ISHM) for Test Stand and J-2X Engine: Core Implementation

    Science.gov (United States)

    Figueroa, Jorge F.; Schmalzel, John L.; Aguilar, Robert; Shwabacher, Mark; Morris, Jon

    2008-01-01

    ISHM capability enables a system to detect anomalies, determine causes and effects, predict future anomalies, and provides an integrated awareness of the health of the system to users (operators, customers, management, etc.). NASA Stennis Space Center, NASA Ames Research Center, and Pratt & Whitney Rocketdyne have implemented a core ISHM capability that encompasses the A1 Test Stand and the J-2X Engine. The implementation incorporates all aspects of ISHM; from anomaly detection (e.g. leaks) to root-cause-analysis based on failure mode and effects analysis (FMEA), to a user interface for an integrated visualization of the health of the system (Test Stand and Engine). The implementation provides a low functional capability level (FCL) in that it is populated with few algorithms and approaches for anomaly detection, and root-cause trees from a limited FMEA effort. However, it is a demonstration of a credible ISHM capability, and it is inherently designed for continuous and systematic augmentation of the capability. The ISHM capability is grounded on an integrating software environment used to create an ISHM model of the system. The ISHM model follows an object-oriented approach: includes all elements of the system (from schematics) and provides for compartmentalized storage of information associated with each element. For instance, a sensor object contains a transducer electronic data sheet (TEDS) with information that might be used by algorithms and approaches for anomaly detection, diagnostics, etc. Similarly, a component, such as a tank, contains a Component Electronic Data Sheet (CEDS). Each element also includes a Health Electronic Data Sheet (HEDS) that contains health-related information such as anomalies and health state. Some practical aspects of the implementation include: (1) near real-time data flow from the test stand data acquisition system through the ISHM model, for near real-time detection of anomalies and diagnostics, (2) insertion of the J-2X

  16. Information Entropy Measures for Stand Structural Diversity:Joint Entropy

    Institute of Scientific and Technical Information of China (English)

    Lei Xiangdong; Lu Yuanchang

    2004-01-01

    Structural diversity is the key attribute of a stand. A set of biodiversity measures in ecology was introduced in forest management for describing stand structure, of which Shannon information entropy (Shannon index) has been the most widely used measure of species diversity. It is generally thought that tree size diversity could serve as a good proxy for height diversity. However, tree size diversity and height diversity for stand structure is not completely consistent. Stand diameter cannot reflect height information completely. Either tree size diversity or height diversity is one-dimensional information entropy measure. This paper discussed the method of multiple-dimensional information entropy measure with the concept of joint entropy. It is suggested that joint entropy is a good measure for describing overall stand structural diversity.

  17. Performance of 3.9 GHz SRF cavities at Fermilab's ILCTA_MDB nhorizontal test stand

    Energy Technology Data Exchange (ETDEWEB)

    Harms, Elvin; Hocker, Andy; /Fermilab

    2008-08-01

    Fermilab is building a cryomodule containing four 3.9 GHz superconducting radio frequency (SRF) cavities for the Free electron LASer in Hamburg (FLASH) facility at the Deutsches Elektronen-SYnchrotron (DESY) laboratory. Before assembling the cavities into the cryomodule, each individual cavity is tested at Fermilab's Horizontal Test Stand (HTS). The HTS provides the capability to test fully-dressed SRF cavities at 1.8 K with high-power pulsed RF in order to verify that the cavities achieve performance requirements under these conditions. The performance at the HTS of the 3.9 GHz cavities built for FLASH is presented here.

  18. The role of forest stand structure as biodiversity indicator

    DEFF Research Database (Denmark)

    Gao, Tian; Hedblom, Marcus; Emilsson, Tobias

    2014-01-01

    be achieved if indicators are derived from existing data. In this study, a model for classifying forest stand structures was developed and tested as an indicator of overall plant species diversity at stand level. The model combines four stand structure parameters: canopy coverage, age of canopy trees, tree...... species composition and canopy stratification. Using data from the National Inventory of Landscapes in Sweden and General Linear Mixed Model, plant species diversity (Shannon diversity index, SHDI) and composition (Sørensen-Dice index, SDI) were tested between 26 different stand structure types and nine...... soil classes. The results showed that mature stands with a stratified canopy had the highest plant species diversity across the soil classes, particularly if they comprised mixed coniferous and broadleaved species with a semi-open canopy. In contrast, young (...

  19. A study on special test stand of automatic and manual descent control in presence of simulated g-load effect

    Science.gov (United States)

    Glazkov, Yury; Artjuchin, Yury; Astakhov, Alexander; Vas'kov, Alexander; Malyshev, Veniamin; Mitroshin, Edward; Glinsky, Valery; Moiseenko, Vasily; Makovlev, Vyacheslav

    The development of aircraft-type reusable space vehicles (RSV) involves the problem of complete compatibility of automatic, director and manual control. Task decision is complicated, in particular, due to considerable quantitative and qualitative changes of vehicle dynamic characteristics, little stability margins (and even of unstability) of the RSV, and stringent requirements to control accuracy at some flight phases. Besides, during control a pilot is affected by g-loads which hamper motor activity and deteriorate its accuracy, alter the functional status of the visual analyser, and influence higher nervous activity. A study of g-load effects on the control efficiency, especially in manual and director modes, is of primary importance. The main tools for study of a rational selection of manual and director vehicle control systems and as an aid in formulating recommendations for optimum crew-automatic control system interactions are special complex and functional flight simulator test stands. The proposed simulator stand includes a powerful digital computer complex combined with the control system of the centrifuge. The interior of a pilot's vehicle cabin is imitated. A situation image system, pyscho-physical monitoring system, physician, centrifuge operator, and instructor stations are linked with the test stand.

  20. Development of Start-up and Shutdown Procedure for the HANARO Fuel Test Loop

    International Nuclear Information System (INIS)

    Park, S. K.; Sim, B. S.; Chi, D. Y.; Lee, J. M.; Lee, C. Y.; Ahn, S. H.

    2009-06-01

    A start-up and shutdown procedure for the HANARO fuel test loop has been developed. This is a facility for fuel and material irradiation tests. The facility provides experimental conditions similar to the normal operational pressures and temperatures of commercial PWR and CANDU plants. The normal operation modes of the HANARO fuel test loop are classified into loop shutdown, cold stand-by 1, cold stand-by 2, hot stand-by, and hot operation. The operation modes depend on the fission power of test fuels and the coolant temperature at the inlet of the in-pile test section. The HANARO must maintain a shutdown mode if the HANARO fuel test loop is loop shutdown, cold stand-by 1, cold stand-by 2, or hot stand-by. As the HANARO becomes power operation mode, the operation mode of the HANARO fuel test loop comes to hot operation from hot stand-by. The procedure for the HANARO fuel test loop consists of four main parts such as check of initial conditions, stat-up operation procedure, shutdown operation procedure, and check lists for operations. Several hot test operations ensure that the procedure is appropriate

  1. The experiences of mastery of stand-by energy demand; Les experiences de MDE stand by

    Energy Technology Data Exchange (ETDEWEB)

    Schilken, P

    2001-07-01

    In the residential sector of the OECD countries, the electricity losses of domestic appliances in stand-by position represent 1.5% of the total electricity consumption. This study belongs to the SAVE project (pilot campaign of municipal utilities for an improved rational use of energy). Its aim is to observe the policies and experiments implemented by municipalities and municipal energy companies for the abatement of the electricity consumptions of stand-by origin. A working group consisting of the German Stadtwerke and some international partners have debated the possible actions and documents for an efficient information of the public. This document presents the brochures and local actions of this program. (J.S.)

  2. A microNewton thrust stand for average thrust measurement of pulsed microthruster.

    Science.gov (United States)

    Zhou, Wei-Jing; Hong, Yan-Ji; Chang, Hao

    2013-12-01

    A torsional thrust stand has been developed for the study of the average thrust for microNewton pulsed thrusters. The main body of the thrust stand mainly consists of a torsional balance, a pair of flexural pivots, a capacitive displacement sensor, a calibration assembly, and an eddy current damper. The behavior of the stand was thoroughly studied. The principle of thrust measurement was analyzed. The average thrust is determined as a function of the average equilibrium angle displacement of the balance and the spring stiffness. The thrust stand has a load capacity up to 10 kg, and it can theoretically measure the force up to 609.6 μN with a resolution of 24.4 nN. The static calibrations were performed based on the calibration assembly composed of the multiturn coil and the permanent magnet. The calibration results demonstrated good repeatability (less than 0.68% FSO) and good linearity (less than 0.88% FSO). The assembly of the multiturn coil and the permanent magnet was also used as an exciter to simulate the microthruster to further research the performance of the thrust stand. Three sets of force pulses at 17, 33.5, and 55 Hz with the same amplitude and pulse width were tested. The repeatability error at each frequency was 7.04%, 1.78%, and 5.08%, respectively.

  3. Simulated stand tests and centrifuge training to prevent orthostatic intolerance on Earth, moon, and Mars.

    Science.gov (United States)

    Coats, Brandon W; Sharp, M Keith

    2010-03-01

    One proposed method to overcome postflight orthostatic intolerance is for astronauts to undergo inflight centrifugation. Cardiovascular responses were compared between centrifuge and gravitational conditions using a seven-compartment cardiovascular model. Vascular resistance, heart rate, and stroke volume values were adopted from literature, while compartmental volumes and compliances were derived from impedance plethysmography of subjects (n=8) riding on a centrifuge. Three different models were developed to represent the typical male subject who completed a 10-min postflight stand test ("male finisher"), "non-finishing male" and "female" (all non-finishers). A sensitivity analysis found that both cardiac output and arterial pressure were most sensitive to total blood volume. Simulated stand tests showed that female astronauts were more susceptible to orthostatic intolerance due to lower initial blood pressure and higher pressure threshold for presyncope. Rates of blood volume loss by capillary filtration were found to be equivalent in female and male non-finishers, but four times smaller in male finishers. For equivalent times to presyncope during centrifugation as those during constant gravity, lower G forces at the level of the heart were required. Centrifuge G levels to match other cardiovascular parameters varied depending on the parameter, centrifuge arm length, and the gravity level being matched.

  4. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke

    DEFF Research Database (Denmark)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla

    2016-01-01

    OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability...... of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error...... of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0...

  5. A diagnostic test for apraxia in stroke patients: internal consistency and diagnostic value.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, F.C.; Kinebanian, A.

    1999-01-01

    The internal consistency and the diagnostic value of a test for apraxia in patients having had a stroke are presented. Results indicate that the items of the test form a strong and consistent scale: Cronbach's alpha as well as the results of a Mokken scale analysis present good reliability and good

  6. Electromagnetic calibration system for sub-micronewton torsional thrust stand

    Science.gov (United States)

    Lam, J. K.; Koay, S. C.; Cheah, K. H.

    2017-12-01

    It is critical for a micropropulsion system to be evaluated. Thrust stands are widely recognised as the instrument to complete such tasks. This paper presents the development of an alternative electromagnetic calibration technique for thrust stands. Utilising the commercially made voice coils and permanent magnets, the proposed system is able to generate repeatable and also consistent steady-state calibration forces at over four orders of magnitude (30 - 23000 μN). The system is then used to calibrate a custom-designed torsional thrust stand, where its inherent ability in ease of setup is well demonstrated.

  7. Vibrational multiconfiguration self-consistent field theory: implementation and test calculations.

    Science.gov (United States)

    Heislbetz, Sandra; Rauhut, Guntram

    2010-03-28

    A state-specific vibrational multiconfiguration self-consistent field (VMCSCF) approach based on a multimode expansion of the potential energy surface is presented for the accurate calculation of anharmonic vibrational spectra. As a special case of this general approach vibrational complete active space self-consistent field calculations will be discussed. The latter method shows better convergence than the general VMCSCF approach and must be considered the preferred choice within the multiconfigurational framework. Benchmark calculations are provided for a small set of test molecules.

  8. Standing Up for Learning: A Pilot Investigation on the Neurocognitive Benefits of Stand-Biased School Desks

    Directory of Open Access Journals (Sweden)

    Ranjana K. Mehta

    2015-12-01

    Full Text Available Standing desks have proven to be effective and viable solutions to combat sedentary behavior among children during the school day in studies around the world. However, little is known regarding the potential of such interventions on cognitive outcomes in children over time. The purpose of this pilot study was to determine the neurocognitive benefits, i.e., improvements in executive functioning and working memory, of stand-biased desks and explore any associated changes in frontal brain function. 34 freshman high school students were recruited for neurocognitive testing at two time points during the school year: (1 in the fall semester and (2 in the spring semester (after 27.57 (1.63 weeks of continued exposure. Executive function and working memory was evaluated using a computerized neurocognitive test battery, and brain activation patterns of the prefrontal cortex were obtained using functional near infrared spectroscopy. Continued utilization of the stand-biased desks was associated with significant improvements in executive function and working memory capabilities. Changes in corresponding brain activation patterns were also observed. These findings provide the first preliminary evidence on the neurocognitive benefits of standing desks, which to date have focused largely on energy expenditure. Findings obtained here can drive future research with larger samples and multiple schools, with comparison groups that may in turn implicate the importance of stand-biased desks, as simple environmental changes in classrooms, on enhancing children’s cognitive functioning that drive their cognitive development and impact educational outcomes.

  9. The stand prototype of minimum power NRE reactor

    International Nuclear Information System (INIS)

    Belogurov, A.I.; Grigorenko, L.N.; Mamontov, Yu.I.; Rachuk, V.S.; Stukalov, A.I.; Konyukhov, G.V.

    1995-01-01

    For ensuring of full-scale development of nuclear rocket engine (NRE) reactor was created stand prototype (reactor IRGIT?) The main differences of its are as follows: 1) Fasteners of technologies channels contents fuel assemblies in bottom are worked out the split. It is provides possibility a distance channels change without disassembly of reactor stand prototype from stand; 2) Cooling of the vessels, the moderator, the reflector and the barrel actuate is carried out by hydrogen; 3) The lower bottom modified for organization the hydrogen efflux in the form a reactor jet; 4) Radiation defence is introduced as part of stand prototype for ensuring of serviceability of stand accessories and tests routine service; 5) Each technology channels is provided of critical nozzle; 6) Control, regulation and defence of reactor has being carried out on stand system

  10. Practical research of free standing rack. Seismic experiment study on full scale free standing rack

    International Nuclear Information System (INIS)

    Iwasaki, Akihisa; Nekomoto, Yoshitsugu; Morita, Hideyuki; Taniguchi, Katsuhiko; Okuno, Daisaku; Matsuoka, Toshihiro; Chigusa, Naoki

    2015-01-01

    The spent fuel taken out of a plant reactor is temporarily stored in a spent fuel rack. This fuel will often have to be stored in the rack for long periods before it can be moved to a reprocessing facility. Therefore, the spent fuel rack must have a high tolerance against big seismic loads. The free standing spent fuel rack has been developed as the optimal equipment meeting these requirements. It can be placed on the spent fuel pool floor without fixation to any support structure. Response of the free standing rack is reduced by the effect of the water and friction force on the spent fuel pool floor. For nuclear plant safety, it is necessary to understand the free standing rack behavior under earthquake in pools to verify the design of free standing racks and peripheral components. Several tests on a shaking table have been conducted on full-scale one free standing rack in air and in water, and sliding and rocking have been measured. The rack response is very complex and the study necessitates to take into account the sliding, the rocking, the effect of the water and of the arrangement of the fuel assemblies inside. (author)

  11. A test of high-dose verbenone for stand-level protection of lodgepole and whitebark pine from mountain pine beetle (Coleoptera: Curculionidae: Scolytinae) attacks

    Science.gov (United States)

    B. J. Bentz; S. Kegley; K. Gibson; R. Their

    2005-01-01

    The effcacy of verbenone as a stand-level protectant against mountain pine beetle, Dendroctonus ponderosae Hopkins, attacks was tested in lodgepole and whitebark pine stands at five geographically separated sites, including three consecutive years at one site. Forty and 20 high-dose pouches, with a verbenone emission rate up to 50 mg/d per pouch, were spaced in a grid...

  12. Validation and test report

    DEFF Research Database (Denmark)

    Pedersen, Jens Meldgaard; Andersen, T. Bull

    2012-01-01

    . As a consequence of extensive movement artefacts seen during dynamic contractions, the following validation and test report consists of a report that investigates the physiological responses to a static contraction in a standing and a supine position. Eight subjects performed static contractions of the ankle...

  13. Association of unipedal standing time and bone mineral density in community-dwelling Japanese women.

    Science.gov (United States)

    Sakai, A; Toba, N; Takeda, M; Suzuki, M; Abe, Y; Aoyagi, K; Nakamura, T

    2009-05-01

    Bone mineral density (BMD) and physical performance of the lower extremities decrease with age. In community-dwelling Japanese women, unipedal standing time, timed up and go test, and age are associated with BMD while in women aged 70 years and over, unipedal standing time is associated with BMD. The aim of this study was to clarify whether unipedal standing time is significantly associated with BMD in community-dwelling women. The subjects were 90 community-dwelling Japanese women aged 54.7 years. BMD of the second metacarpal bone was measured by computed X-ray densitometry. We measured unipedal standing time as well as timed up and go test to assess physical performance of the lower extremities. Unipedal standing time decreased with increased age. Timed up and go test significantly correlated with age. Low BMD was significantly associated with old age, short unipedal standing time, and long timed up and go test. Stepwise regression analysis revealed that age, unipedal standing time, and timed up and go test were significant factors associated with BMD. In 21 participants aged 70 years and over, body weight and unipedal standing time, but not age, were significantly associated with BMD. BMD and physical performance of the lower extremities decrease with older age. Unipedal standing time, timed up and go test, and age are associated with BMD in community-dwelling Japanese women. In women aged 70 years and over, unipedal standing time is significantly associated with BMD.

  14. Test-retest reliability and minimal detectable change scores for sit-to-stand-to-sit tests, the six-minute walk test, the one-leg heel-rise test, and handgrip strength in people undergoing hemodialysis.

    Science.gov (United States)

    Segura-Ortí, Eva; Martínez-Olmos, Francisco José

    2011-08-01

    Determining the relative and absolute reliability of outcomes of physical performance tests for people undergoing hemodialysis is necessary to discriminate between the true effects of exercise interventions and the inherent variability of this cohort. The aims of this study were to assess the relative reliability of sit-to-stand-to-sit tests (the STS-10, which measures the time [in seconds] required to complete 10 full stands from a sitting position, and the STS-60, which measures the number of repetitions achieved in 60 seconds), the Six-Minute Walk Test (6MWT), the one-leg heel-rise test, and the handgrip strength test and to calculate minimal detectable change (MDC) scores in people undergoing hemodialysis. This study was a prospective, nonexperimental investigation. Thirty-nine people undergoing hemodialysis at 2 clinics in Spain were contacted. Study participants performed the STS-10 (n=37), the STS-60 (n=37), and the 6MWT (n=36). At one of the settings, the participants also performed the one-leg heel-rise test (n=21) and the handgrip strength test (n=12) on both the right and the left sides. Participants attended 2 testing sessions 1 to 2 weeks apart. High intraclass correlation coefficients (≥.88) were found for all tests, suggesting good relative reliability. The MDC scores at 90% confidence intervals were as follows: 8.4 seconds for the STS-10, 4 repetitions for the STS-60, 66.3 m for the 6MWT, 3.4 kg for handgrip strength (force-generating capacity), 3.7 repetitions for the one-leg heel-rise test with the right leg, and 5.2 repetitions for the one-leg heel-rise test with the left leg. Limitations A limited sample of patients was used in this study. The STS-16, STS-60, 6MWT, one-leg heel rise test, and handgrip strength test are reliable outcome measures. The MDC scores at 90% confidence intervals for these tests will help to determine whether a change is due to error or to an intervention.

  15. F-15B ACTIVE with thrust vectoring nozzles on test stand at sunrise

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the aircraft on a test stand at sunrise. Not shown in this photograph are the aircraft's two new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. These nozzles give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. These tests could result in significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace. The aircraft was originally built as an F-15B (Serial #71-0290).

  16. A stand alone computer system to aid the development of mirror fusion test facility RF heating systems

    International Nuclear Information System (INIS)

    Thomas, R.A.

    1983-01-01

    The Mirror Fusion Test Facility (MFTF-B) control system architecture requires the Supervisory Control and Diagnostic System (SCDS) to communicate with a LSI-11 Local Control Computer (LCC) that in turn communicates via a fiber optic link to CAMAC based control hardware located near the machine. In many cases, the control hardware is very complex and requires a sizable development effort prior to being integrated into the overall MFTF-B system. One such effort was the development of the Electron Cyclotron Resonance Heating (ECRH) system. It became clear that a stand alone computer system was needed to simulate the functions of SCDS. This paper describes the hardware and software necessary to implement the SCDS Simulation Computer (SSC). It consists of a Digital Equipment Corporation (DEC) LSI-11 computer and a Winchester/Floppy disk operating under the DEC RT-11 operating system. All application software for MFTF-B is programmed in PASCAL, which allowed us to adapt procedures originally written for SCDS to the SSC. This nearly identical software interface means that software written during the equipment development will be useful to the SCDS programmers in the integration phase

  17. The 1-min sit-to-stand test in cystic fibrosis - Insights into cardiorespiratory responses.

    Science.gov (United States)

    Radtke, Thomas; Hebestreit, Helge; Puhan, Milo A; Kriemler, Susi

    2017-11-01

    We aimed to characterize the cardiopulmonary response during a 1-min sit-to-stand (STS) test and compare peak exercise cardiorespiratory variables to a maximal cardiopulmonary exercise test (CPET) in cystic fibrosis (CF). We further aimed to assess the validity of the STS power index (Power STS ) as a measure of exercise capacity. Fifteen adult CF patients performed spirometry, CPET and the 1-min STS test with respiratory gas analysis. Peak-exercise cardiorespiratory variables during the 1-min STS test correlated strongly (r=0.69-0.98) with those measured during the CPET. Oxygen uptake, carbon dioxide production, heart rate, ventilation, and tidal volume at peak exercise were 24%, 26%, 9%, 10% and 21% lower in the 1-min STS test, while respiratory frequencies were 14% higher. Power STS showed strong to very strong correlations with CPET-derived absolute peak oxygen uptake and maximal workload. The 1-min STS test elicits a substantial but lower cardiorespiratory response compared to a maximal cycle ergometry CPET. While Power STS and STS repetitions are both valid outcome measures of functional capacity, STS repetitions are clinically more practical. Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  18. RF-Breakdown kicks at the CTF3 two-beam test stand

    CERN Document Server

    Palaia, Andrea; Muranaka, Tomoko; Ruber, Roger; Ziemann, V; Farabolini, W

    2012-01-01

    The measurement of the effects of RF-breakdown on the beam in CLIC prototype accelerator structures is one of the key aspects of the CLIC two-beam acceleration scheme being addressed at the Two-beam Test Stand (TBTS) at CTF3. RF-breakdown can randomly cause energy loss and transverse kicks to the beam. Transverse kicks have been measured by means of a screen intercepting the beam after the accelerator structure. In correspondence of a RFbreakdown we detect a double beam spot which we interpret as a sudden change of the beam trajectory within a single beam pulse. To time-resolve such effect, the TBTS has been equipped with five inductive Beam Position Monitors (BPMs) and a spectrometer line to measure both relative changes of the beam trajectory and energy losses. Here we discuss the methodology used and we present the latest results of such measurements

  19. Main Propulsion Test Article (MPTA)

    Science.gov (United States)

    Snoddy, Cynthia

    2010-01-01

    Scope: The Main Propulsion Test Article integrated the main propulsion subsystem with the clustered Space Shuttle Main Engines, the External Tank and associated GSE. The test program consisted of cryogenic tanking tests and short- and long duration static firings including gimbaling and throttling. The test program was conducted on the S1-C test stand (Position B-2) at the National Space Technology Laboratories (NSTL)/Stennis Space Center. 3 tanking tests and 20 hot fire tests conducted between December 21 1 1977 and December 17, 1980 Configuration: The main propulsion test article consisted of the three space shuttle main engines, flightweight external tank, flightweight aft fuselage, interface section and a boilerplate mid/fwd fuselage truss structure.

  20. System integration and performance of the EUV engineering test stand

    International Nuclear Information System (INIS)

    Tichenor, Daniel A.; Ray-Chaudhuri, Avijit K.; Replogle, William C.; Stulen, Richard H.; Kubiak, Glenn D.; Rockett, Paul D.; Klebanoff, Leonard E.; Jefferson, Karen L.; Leung, Alvin H.; Wronosky, John B.; Hale, Layton C.; Chapman, Henry N.; Taylor, John S.; Folta, James A.; Montcalm, Claude; Soufli, Regina; Spiller, Eberhard; Blaedel, Kenneth; Sommargren, Gary E.; Sweeney, Donald W.; Naulleau, Patrick; Goldberg, Kenneth A.; Gullikson, Eric M.; Bokor, Jeffrey; Batson, Phillip J.; Attwood, David T.; Jackson, Keith H.; Hector, Scott D.; Gwyn, Charles W.; Yan, Pei-Yang; Yan, P.

    2001-01-01

    The Engineering Test Stand (ETS) is a developmental lithography tool designed to demonstrate full-field EUV imaging and provide data for commercial-tool development. In the first phase of integration, currently in progress, the ETS is configured using a developmental projection system, while fabrication of an improved projection system proceeds in parallel. The optics in the second projection system have been fabricated to tighter specifications for improved resolution and reduced flare. The projection system is a 4-mirror, 4x-reduction, ring-field design having a numeral aperture of 0.1, which supports 70 nm resolution at a k 1 of 0.52. The illuminator produces 13.4 nm radiation from a laser-produced plasma, directs the radiation onto an arc-shaped field of view, and provides an effective fill factor at the pupil plane of 0.7. The ETS is designed for full-field images in step-and-scan mode using vacuum-compatible, magnetically levitated, scanning stages. This paper describes system performance observed during the first phase of integration, including static resist images of 100 nm isolated and dense features

  1. Simple Excitation of Standing Waves in Rubber Bands and Membranes

    Science.gov (United States)

    Cortel, Adolf

    2004-04-01

    Many methods to excite standing waves in strings, plates, membranes, rods, tubes, and soap bubbles have been described. Usually a loudspeaker or a vibrating reed is driven by the amplified output of an audio oscillator. A novel and simple method consists of using a tuning fork or a singing rod to excite transversal standing waves in stretched rubber membranes sprinkled with fine sand.

  2. Minutes of Proceedings and Evidence of the Standing Committee on External Affairs and International Trade Respecting: Pursuant to Standing Order 108(2), consideration of nuclear dumping and testing in the Russian Arctic

    International Nuclear Information System (INIS)

    1993-01-01

    The Standing Committee on External Affairs and International Trade met to consider the nuclear dumping and testing in the Russian Arctic. Canada is concerned about the environmental effects of the radioactive waste to the marine environment. The safe dismantlement of nuclear weapons or reactors is of major concern

  3. Minutes of Proceedings and Evidence of the Standing Committee on External Affairs and International Trade Respecting: Pursuant to Standing Order 108(2), consideration of nuclear dumping and testing in the Russian Arctic

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Standing Committee on External Affairs and International Trade met to consider the nuclear dumping and testing in the Russian Arctic. Canada is concerned about the environmental effects of the radioactive waste to the marine environment. The safe dismantlement of nuclear weapons or reactors is of major concern.

  4. Physics design of a 10 MeV injector test stand for an accelerator-driven subcritical system

    Science.gov (United States)

    Yan, Fang; Pei, Shilun; Geng, Huiping; Meng, Cai; Zhao, Yaliang; Sun, Biao; Cheng, Peng; Yang, Zheng; Ouyang, Huafu; Li, Zhihui; Tang, Jingyu; Wang, Jianli; Sui, Yefeng; Dai, Jianping; Sha, Peng; Ge, Rui

    2015-05-01

    The 10 MeV accelerator-driven subcritical system (ADS) Injector I test stand at Institute of High Energy Physics (IHEP) is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at 325 MHz], for the ADS project in China. The injector is composed of two parts, the linac part and the beam dump line. The former is designed on the basis of 325 MHz four-vane type copper structure radio frequency quadrupole and superconducting (SC) spoke cavities with β =0.12 . The latter is designed to transport the beam coming out of the SC section of the linac to the beam dump, where the beam transverse profile is fairly enlarged and unformed to simplify the beam target design. The SC section consists of two cryomodules with 14 β =0.12 Spoke cavities, 14 solenoid and 14 BPMs in total. The first challenge in the physics design comes from the necessary space required for the cryomodule separation where the periodical lattice is destroyed at a relatively lower energy of ˜5 MeV . Another challenge is the beam dump line design, as it will be the first beam dump line being built by using a step field magnet for the transverse beam expansion and uniformity in the world. This paper gives an overview of the physics design study together with the design principles and machine construction considerations. The results of an optimized design, fabrication status and end to end simulations including machine errors are presented.

  5. Natural regeneration of trees in three types of afforested stands in the Taihang Mountains, China.

    Directory of Open Access Journals (Sweden)

    Xitian Yang

    Full Text Available Natural regeneration is the natural process by which plants replace themselves. It is a cost-effective way to re-establish vegetation, and it helps to preserve genetic identity and diversity. In this study, we investigated the natural regeneration of trees in three types of afforested stands in the Taihang Mountains, China, which were dominated by Robinia pseudoacacia (black locust, Quercus variabilis (Chinese cork oak and Platycladus orientalis (Chinese arborvitae respectively. A consistent pattern was found among the three types of stands, being that the density of seedlings was positively correlated with the overstory canopy cover and negatively correlated with the covers of shrub, herb and litter layers. While a positive correlation between the density of seedlings and stand age was found for the conifer stands, negative correlations were found for the two types of broadleaf stands. Correlations between the density of saplings and the stand attributes were not consistent among the three types of stands. The two types of broadleaf stands had higher densities of seedlings and saplings than the conifer stands. While the broadleaf stands had adequate recruits for regeneration, the conifer stands did not have enough recruits. Our findings suggest that the overstory canopy should be prevented from being disturbed, any reduction of the canopy cover will decrease the recruits and affect the regeneration.

  6. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    Directory of Open Access Journals (Sweden)

    E. Adli

    2011-08-01

    Full Text Available We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter regime of CLIC.

  7. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    CERN Document Server

    Adli, E; Dubrovskiy, A; Syratchev, I; Ruber, R; Ziemann, V

    2011-01-01

    We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter reg...

  8. StandsSIM-MD: a Management Driven forest SIMulator

    Energy Technology Data Exchange (ETDEWEB)

    Barreiro, S.; Rua, J.; Tomé, M.

    2016-07-01

    Aim of the study. The existing stand level forest simulators available in Portugal were not developed with the aim of including up-to-date model versions and were limited in terms of accounting for forest management. The simulators’ platform, sIMfLOR was recently created to implement different growth models with a common philosophy. The objective was developing one easily-updatable, user-friendly, forest management and climate change sensitive simulator capable of projecting growth for the main tree species in Portugal. Area of the study: Portugal. Material and methods: The new simulator was programmed in a modular form consisting of several modules. The growth module integrates different forest growth and yield models (empirical and process-based) for the main wood production tree species in Portugal (eucalypt, umbrella and maritime pines); whereas the management module drives the growth projections along the planning horizon according to a range of forest management approaches and climate (at present only available for eucalypt). Main results: The main result is the StandsSIM-MD Management Driven simulator that overcomes the limitations of the existing stand level simulators. It is a step forward when compared to the models currently available in the sIMfLOR platform covering more tree species, stand structures and stand compositions. It is focused on end-users and it is based on similar concepts regarding the generation of required inputs and generated outputs. Research highlights: Forest Management Driven simulations approach. Multiple Prescriptions-Per-Stand functionality. StandsSIM-MD can be used to support landowners decisions on stand forest management. StandsSIM-MD simulations at regional level can be combined with optimization routines. (Author)

  9. Effect of foot placements during sit to stand transition on timed up and go test in stroke subjects: A cross sectional study.

    Science.gov (United States)

    Joshua, Abraham M; Karnad, Shreekanth D; Nayak, Akshatha; Suresh, B V; Mithra, Prasanna; Unnikrishnan, B

    2017-01-01

    Timed up and go (TUG) test is been used as a screening tool for the assessment of risk of falling in individuals following stroke. Though TUG test is a quick test, it has fair sensitivity compared to other tests. This study was carried out to obtain and compare test scores for different types of foot placements during sit to stand transition in stroke subjects. A Cross-sectional study with purposive sampling included 28 post stroke subjects who were able to walk 6 meter with or without assistance. Timed Up and Go test was carried out with four different types of foot placements and scores were recorded. The data were compared using Kruskal-Wallis One way analysis of variance and Wilcoxon signed ranks test. There were comparable differences between asymmetric 1 test strategy which involved affected extremity to be placed behind the unaffected and other test strategies (Z = -4.457,-3.848,-4.458; p = 0.000). The initial foot placements during sit to stand transition influenced the time taken to complete the test which was significantly higher in asymmetric 1 strategy, Incorporation of the initial foot placement mainly asymmetric 1 strategy into conventional TUG test would help in identifying accurately the subject's functional mobility and postural stability.

  10. Standing footprint diagnostic method

    Science.gov (United States)

    Fan, Y. F.; Fan, Y. B.; Li, Z. Y.; Newman, T.; Lv, C. S.; Fan, Y. Z.

    2013-10-01

    Center of pressure is commonly used to evaluate standing balance. Even though it is incomplete, no better evaluation method has been presented. We designed our experiment with three standing postures: standing with feet together, standing with feet shoulder width apart, and standing with feet slightly wider than shoulder width. Our platform-based pressure system collected the instantaneous plantar pressure (standing footprint). A physical quantity of instantaneous standing footprint principal axis was defined, and it was used to construct an index to evaluate standing balance. Comparison between results from our newly established index and those from the center of pressure index to evaluate the stability of different standing postures revealed that the standing footprint principal axis index could better respond to the standing posture change than the existing one. Analysis indicated that the insensitive response to the relative position between feet and to the standing posture change from the center of pressure could be better detected by the standing footprint principal axis index. This predicts a wide application of standing footprint principal axis index when evaluating standing balance.

  11. Take a Stand!

    DEFF Research Database (Denmark)

    Danquah, I. H.; Kloster, S.; Holtermann, A.

    2017-01-01

    workers in total) were cluster randomized for intervention or control. The intervention included the appointment of local ambassadors, management support, environmental changes, a lecture and a workshop. Sitting time was measured using an ActiGraph GT3X+ fixed on the thigh. Data were processed using Acti4......Background: Prolonged sitting time has been associated with adverse health outcomes. Interventions at work may contribute to reduced sitting. The objective was to test if a multicomponent work-based intervention can reduce sitting time and the number of prolonged sitting periods (> 30 min......), increase the number of sit-to-stand transitions and decrease waist circumference and body fat percentage among office workers. Primary outcomes were: change in sitting time, prolonged sitting periods and sit-to-stand transitions at followup 1 month later. Methods: At four workplaces, 19 offices (317...

  12. Effect of posterior tibial tendon dysfunction on unipedal standing balance test.

    Science.gov (United States)

    Kulig, Kornelia; Lee, Szu-Ping; Reischl, Stephen F; Noceti-DeWit, Lisa

    2015-01-01

    Foot pain and diminished functional capacity are characteristics of tibialis posterior tendon dysfunction (TPTD). This study tested the hypotheses that women with TPTD would have impaired performance of a unipedal standing balance test (USBT) and that balance performance would be related to the number of single limb heel raises (SLHR). Thirty-nine middle-aged women, 19 with early stage TPTD (stage I and II), were instructed to perform 2 tasks; a USBT and repeated SLHR. Balance success was defined as a 10-second stance. For those who were successful, center of pressure (COP) data in anterior-posterior (AP) and medial-lateral (ML) directions were recorded as a measure of postural sway. SLHR performance was divided into 3 bins (≤2; 3-9 and > 10 repetitions). The between-balance success on performing the SLHR test was analyzed using the Fisher's exact test (2 × 3). Independent t tests were used to compare between-group differences in postural sway. Relationship of postural sway to the number of heel raises was assessed using Spearman's rho. The success rate of the USBT was significantly lower in women with TPTD than the controls (47% vs 85%, P = .041). In addition, women with TPTD who completed the USBT exhibited increased AP COP displacement (14.0 ± 7.4 vs 8.4 ± 1.3 mm, P = .008), and a strong trend of increased ML COP displacement (8.3 ± 4.5 vs 6.1 ± 1.2 mm, P = .050). The success rate of USBT was correlated with the number of SLHR (P = .01). The AP and ML COP displacement were correlated with SLHR (r = -.538 and .495), respectively. Women with TPTD have difficulty in performing the USBT. Performance of the USBT and SLHR are highly correlated and predictive of each other. A unipedal balance test may be used as a proxy TPTD assessment tool to the heel raising test when pain prevents performance. Level III, case control study. © The Author(s) 2014.

  13. Vacuum system design considerations of the Los Alamos Accelerator Test Stand (ATS)

    International Nuclear Information System (INIS)

    Wilson, N.G.

    1986-01-01

    The accelerator test stand (ATS), in operation at the Los Alamos National Laboratory, includes a hydrogen ion source, low- and high-energy beam-transport sections, and a 425-MHz radio-frequency quadrupole (RFQ) linear accelerator. A 425-MHz drift-tube linac (DTL) and a powered ''buncher'' matching section have been constructed and will be installed on the ATS. The vacuum systems required for the various sections of the ATS are designed to provide: (1) high gas-load capability, as required in the ion source, and (2) high-vacuum capability in the high-power, radio-frequency accelerator sections (where fast vacuum-system response time is of importance) through the use of distributed, differential pumping as a principal vacuum-system feature. This paper describes properties of accelerator materials, vacuum-systems engineering and analysis, vacuum equipment used, and ATS vacuum-system performance

  14. Test of Gross Motor Development : Expert Validity, confirmatory validity and internal consistence

    Directory of Open Access Journals (Sweden)

    Nadia Cristina Valentini

    2008-12-01

    Full Text Available The Test of Gross Motor Development (TGMD-2 is an instrument used to evaluate children’s level of motordevelopment. The objective of this study was to translate and verify the clarity and pertinence of the TGMD-2 items by expertsand the confirmatory factorial validity and the internal consistence by means of test-retest of the Portuguese TGMD-2. Across-cultural translation was used to construct the Portuguese version. The participants of this study were 7 professionalsand 587 children, from 27 schools (kindergarten and elementary from 3 to 10 years old (51.1% boys and 48.9% girls.Each child was videotaped performing the test twice. The videotaped tests were then scored. The results indicated thatthe Portuguese version of the TGMD-2 contains clear and pertinent motor items; demonstrated satisfactory indices ofconfirmatory factorial validity (χ2/gl = 3.38; Goodness-of-fit Index = 0.95; Adjusted Goodness-of-fit index = 0.92 and Tuckerand Lewis’s Index of Fit = 0.83 and test-retest internal consistency (locomotion r = 0.82; control of object: r = 0.88. ThePortuguese TGMD-2 demonstrated validity and reliability for the sample investigated.

  15. Test of Gross Motor Development: expert validity, confirmatory validity and internal consistence

    Directory of Open Access Journals (Sweden)

    Nadia Cristina Valentini

    2008-01-01

    The Test of Gross Motor Development (TGMD-2 is an instrument used to evaluate children’s level of motor development. The objective of this study was to translate and verify the clarity and pertinence of the TGMD-2 items by experts and the confirmatory factorial validity and the internal consistence by means of test-retest of the Portuguese TGMD-2. A cross-cultural translation was used to construct the Portuguese version. The participants of this study were 7 professionals and 587 children, from 27 schools (kindergarten and elementary from 3 to 10 years old (51.1% boys and 48.9% girls. Each child was videotaped performing the test twice. The videotaped tests were then scored. The results indicated that the Portuguese version of the TGMD-2 contains clear and pertinent motor items; demonstrated satisfactory indices of confirmatory factorial validity (÷2/gl = 3.38; Goodness-of-fit Index = 0.95; Adjusted Goodness-of-fit index = 0.92 and Tucker and Lewis’s Index of Fit = 0.83 and test-retest internal consistency (locomotion r = 0.82; control of object: r = 0.88. The Portuguese TGMD-2 demonstrated validity and reliability for the sample investigated.

  16. Refuge alternatives relief valve testing and design with updated test stand.

    Science.gov (United States)

    Lutz, T J; Bissert, P T; Homce, G T; Yonkey, J A

    2018-03-01

    Underground refuge alternatives require an air source to supply breathable air to the occupants. This requires pressure relief valves to prevent unsafe pressures from building up within the refuge alternative. The U.S. Mine Safety and Health Administration (MSHA) mandates that pressure relief valves prevent pressure from exceeding 1.25 kPa (0.18 psi), or as specified by the manufacturer, above mine atmospheric pressure when a fan or compressor is used for the air supply. The U.S. National Institute for Occupational Safety and Health (NIOSH) tested a variety of pressure relief valves using an instrumented test fixture consisting of data acquisition equipment, a centrifugal blower, ductwork and various sensors to determine if the subject pressure relief valves meet the MSHA requirement. Relief pressures and flow characteristics, including opening pressure and flow rate, were measured for five different pressure relief valves under a variety of conditions. The subject pressure relief valves included two off-the-shelf modified check valves, two check valves used in MSHA-approved built-in-place refuge alternatives, and a commercially available valve that was designed for a steel refuge alternative and is currently being used in some built-in-place refuge alternatives. The test results showed relief pressures ranging from 0.20 to 1.53 kPa (0.03 to 0.22 psi) and flow rates up to 19.3 m 3 /min (683 scfm). As tested, some of the pressure relief valves did not meet the 1.25 kPa (0.18 psi) relief specification.

  17. Development of 20 kW input power coupler for 1.3 GHz ERL main linac. Component test at 30 kW IOT test stand

    International Nuclear Information System (INIS)

    Sakai, Hiroshi; Umemori, Kensei; Sakanaka, Shogo; Takahashi, Takeshi; Furuya, Takaaki; Shinoe, Kenji; Ishii, Atsushi; Nakamura, Norio; Sawamura, Masaru

    2009-01-01

    We started to develop an input coupler for a 1.3 GHz ERL superconducting cavity. Required input power is about 20 kW for the cavity acceleration field of 20 MV/m and the beam current of 100 mA in energy recovery operation. The input coupler is designed based on the STF-BL input coupler and some modifications are applied to the design for the CW 20 kW power operation. We fabricated input coupler components such as ceramic windows and bellows and carried out the high-power test of the components by using a 30 kW IOT power source and a test stand constructed for the highpower test. In this report, we mainly describe the results of the high-power test of ceramic window and bellows. (author)

  18. Age-Related Differences in Quality of Standing Balance Using a Composite Score

    NARCIS (Netherlands)

    Pasma, J.H.; Bijlsma, A.Y.; van der Bij, M.D.W.; Arendzen, J.H.; Meskers, C.G.M.; Maier, A.B.

    2014-01-01

    Background: Age-related differences in standing balance are not detected by testing the ability to maintain balance. Quality of standing balance might be more sensitive to detect age-related differences. Objective: To study age-related differences in quality of standing balance, center of pressure

  19. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1990-01-01

    The product consistency test (PCT) is a glass leach test developed at the Savannah River Site (SRS) to confirm the durability of radioactive nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a seven day, crushed glass leach test in deionized water at 90C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2-5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment. When the results of the two laboratories were compared to each other, the agreement was within 20%. Normalized concentrations for the nonradioactive and radioactive elements in the PCT leachates measured at both facilities indicated that the radionuclides were released from the glass slower than the major soluble elements in the glass. For both laboratories, the normalized releases for both glasses were in the general order Li ∼ B ∼ Na > Si > Cs - 137 > Sb - 125 < Sr - 90. The normalized releases for the major soluble elements and the final pH values in the tests with radioactive glass are consistent with those for nonradioactive glasses with similar compositions. This indicates that there was no significant effect of radiation on the results of the PCT

  20. StandsSIM-MD: a Management Driven forest SIMulator

    Directory of Open Access Journals (Sweden)

    Susana Barreiro

    2016-07-01

    Full Text Available Aim of the study: The existing stand level forest simulators available in Portugal were not developed with the aim of including up-to-date model versions and were limited in terms of accounting for forest management. The simulators’ platform, sIMfLOR was recently created to implement different growth models with a common philosophy. The objective was developing one easily-updatable, user-friendly, forest management and climate change sensitive simulator capable of projecting growth for the main tree species in Portugal. Area of the study: Portugal. Material and methods: The new simulator was programmed in a modular form consisting of several modules. The growth module integrates different forest growth and yield models (empirical and process-based for the main wood production tree species in Portugal (eucalypt, umbrella and maritime pines; whereas the management module drives the growth projections along the planning horizon according to a range of forest management approaches and climate (at present only available for eucalypt. Main results: The main result is the StandsSIM-MD Management Driven simulator that overcomes the limitations of the existing stand level simulators. It is a step forward when compared to the models currently available in the sIMfLOR platform covering more tree species, stand structures and stand compositions. It is focused on end-users and it is based on similar concepts regarding the generation of required inputs and generated outputs. Research highlights: -          Forest Management Driven simulations approach -          Multiple Prescriptions-Per-Stand functionality -          StandsSIM-MD can be used to support landowners decisions on stand forest management -          StandsSIM-MD simulations at regional level can be combined with optimization routines Keywords: Forest simulator, Forest Management Approaches; StandsSIM-MD; forest management.

  1. Physics design of a 10 MeV injector test stand for an accelerator-driven subcritical system

    Directory of Open Access Journals (Sweden)

    Fang Yan

    2015-05-01

    Full Text Available The 10 MeV accelerator-driven subcritical system (ADS Injector I test stand at Institute of High Energy Physics (IHEP is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at 325 MHz], for the ADS project in China. The injector is composed of two parts, the linac part and the beam dump line. The former is designed on the basis of 325 MHz four-vane type copper structure radio frequency quadrupole and superconducting (SC spoke cavities with β=0.12. The latter is designed to transport the beam coming out of the SC section of the linac to the beam dump, where the beam transverse profile is fairly enlarged and unformed to simplify the beam target design. The SC section consists of two cryomodules with 14 β=0.12 Spoke cavities, 14 solenoid and 14 BPMs in total. The first challenge in the physics design comes from the necessary space required for the cryomodule separation where the periodical lattice is destroyed at a relatively lower energy of ∼5  MeV. Another challenge is the beam dump line design, as it will be the first beam dump line being built by using a step field magnet for the transverse beam expansion and uniformity in the world. This paper gives an overview of the physics design study together with the design principles and machine construction considerations. The results of an optimized design, fabrication status and end to end simulations including machine errors are presented.

  2. SMART Rotor Development and Wind Tunnel Test

    Science.gov (United States)

    2009-09-01

    amplifier and control system , and data acquisition, processing, and display systems . Boeing�s LRTS (Fig. 2), consists of a sled structure that...Support Test Stand Sled Tail Sting Outrigger Arm Figure 2: System integration test at whirl tower Port Rotor Balance Main Strut Flap Tail...demonstrated. Finally, the reliability of the flap actuation system was successfully proven in more than 60 hours of wind tunnel testing

  3. Is the timed loaded standing test a valid measure of back muscle endurance in people with vertebral osteoporosis?

    Science.gov (United States)

    Newman, M; Newman, R; Hughes, T; Vadher, K; Barker, K L

    2018-04-01

    Timed loaded standing (TLS) is a suggested measure of back muscle endurance for people with vertebral osteoporosis. Surface electromyography revealed back muscles work harder and fatigue during TLS. The test end-point and total time were associated with back fatigue. The findings help demonstrate the concurrent validity of the TLS test. The TLS test is suggested as a measure of back muscle endurance for patients with vertebral osteoporosis. However, to date, no study has demonstrated that TLS does measure back extensor or erector spinae (ES) muscle endurance. We used surface electromyography (sEMG) to investigate the performance of the thoracic ES muscles during TLS. Thirty-six people with vertebral osteoporosis with a mean age of 71.6 (range 45-86) years participated. sEMG recordings were made of the ES at T3 and T12 bilaterally during quiet standing (QS) and TLS. The relative (%) change in sEMG amplitude between conditions was compared. Fatigue was evaluated by analysing the change in median frequency (MF) of the sEMG signal during TLS, and the correlation between maximal TLS time and rate of MF decline was examined. Activity in the ES increased significantly during TLS at all electrode locations. During TLS, the MF declined at a mean rate of -24.2% per minute (95% C.I. -26.5 to -21.9%). The MF slope and test time were strongly correlated (r 2  = 0.71), and at test end, the final MF dropped to an average 89% (95% C.I. 85 to 93%) of initial MF. Twenty-eight participants (78%) reported fatigue was the main reason for stopping, and for eight (22%), it was pain. This study demonstrates that TLS challenges the ES muscles in the thoracic region and results in ES fatigue. Endurance time and the point at which the TLS test ends are strongly related to ES fatigue.

  4. Method used to test the imaging consistency of binocular camera's left-right optical system

    Science.gov (United States)

    Liu, Meiying; Wang, Hu; Liu, Jie; Xue, Yaoke; Yang, Shaodong; Zhao, Hui

    2016-09-01

    To binocular camera, the consistency of optical parameters of the left and the right optical system is an important factor that will influence the overall imaging consistency. In conventional testing procedure of optical system, there lacks specifications suitable for evaluating imaging consistency. In this paper, considering the special requirements of binocular optical imaging system, a method used to measure the imaging consistency of binocular camera is presented. Based on this method, a measurement system which is composed of an integrating sphere, a rotary table and a CMOS camera has been established. First, let the left and the right optical system capture images in normal exposure time under the same condition. Second, a contour image is obtained based on the multiple threshold segmentation result and the boundary is determined using the slope of contour lines near the pseudo-contour line. Third, the constraint of gray level based on the corresponding coordinates of left-right images is established and the imaging consistency could be evaluated through standard deviation σ of the imaging grayscale difference D (x, y) between the left and right optical system. The experiments demonstrate that the method is suitable for carrying out the imaging consistency testing for binocular camera. When the standard deviation 3σ distribution of imaging gray difference D (x, y) between the left and right optical system of the binocular camera does not exceed 5%, it is believed that the design requirements have been achieved. This method could be used effectively and paves the way for the imaging consistency testing of the binocular camera.

  5. Features of secondary birch young stands in low mountain Pokuttya (Ukrainian Carpathian Mts. )

    OpenAIRE

    MILEVSKAYA S.Y.

    2015-01-01

    Forest landscapes of the region during the last 3–5 centuries undergone the profound anthropogenic transformation. Secondary young stands occupy 25% of the total forest area. The problem of derivatives is particularly relevant for the modern forest typology in the Carpathian region. It requires the reflection in its dynamic trends shaping the stands, especially mixed young stands. The aim of our study consisted in getting the knowledge of the structural features of the secondary phytocoenosis...

  6. Consistence of Network Filtering Rules

    Institute of Scientific and Technical Information of China (English)

    SHE Kun; WU Yuancheng; HUANG Juncai; ZHOU Mingtian

    2004-01-01

    The inconsistence of firewall/VPN(Virtual Private Network) rule makes a huge maintainable cost.With development of Multinational Company,SOHO office,E-government the number of firewalls/VPN will increase rapidly.Rule table in stand-alone or network will be increased in geometric series accordingly.Checking the consistence of rule table manually is inadequate.A formal approach can define semantic consistence,make a theoretic foundation of intelligent management about rule tables.In this paper,a kind of formalization of host rules and network ones for auto rule-validation based on SET theory were proporsed and a rule validation scheme was defined.The analysis results show the superior performance of the methods and demonstrate its potential for the intelligent management based on rule tables.

  7. Consistency checks in beam emission modeling for neutral beam injectors

    International Nuclear Information System (INIS)

    Punyapu, Bharathi; Vattipalle, Prahlad; Sharma, Sanjeev Kumar; Baruah, Ujjwal Kumar; Crowley, Brendan

    2015-01-01

    In positive neutral beam systems, the beam parameters such as ion species fractions, power fractions and beam divergence are routinely measured using Doppler shifted beam emission spectrum. The accuracy with which these parameters are estimated depend on the accuracy of the atomic modeling involved in these estimations. In this work, an effective procedure to check the consistency of the beam emission modeling in neutral beam injectors is proposed. As a first consistency check, at a constant beam voltage and current, the intensity of the beam emission spectrum is measured by varying the pressure in the neutralizer. Then, the scaling of measured intensity of un-shifted (target) and Doppler shifted intensities (projectile) of the beam emission spectrum at these pressure values are studied. If the un-shifted component scales with pressure, then the intensity of this component will be used as a second consistency check on the beam emission modeling. As a further check, the modeled beam fractions and emission cross sections of projectile and target are used to predict the intensity of the un-shifted component and then compared with the value of measured target intensity. An agreement between the predicted and measured target intensities provide the degree of discrepancy in the beam emission modeling. In order to test this methodology, a systematic analysis of Doppler shift spectroscopy data obtained on the JET neutral beam test stand data was carried out

  8. Nuclear waste glass product consistency test (PCT), Version 5.0

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.; Waters, B.J.

    1992-06-01

    Liquid high-level nuclear waste will be immobilized at the Savannah River Site (SRS) by vitrification in borosilicate glass. The glass will be produced in the Defense Waste Processing Facility (DWPF), poured into stainless steel canisters, and eventually disposed of in a geologic repository. In order to comply with the Waste Acceptance Preliminary Specifications (WAPS), the durability of the glass needs to be measured during production to assure its long term stability and radionuclide release properties. A durability test, designated the Produce Consistency Test (PCT), was developed for DWPF glass in order to meet the WAPS requirements. The response of the PCT procedure was based on extensive testing with glasses of widely different compositions. The PCT was determined to be very reproducible, to yield reliable results rapidly, and to be easily performed in shielded cell facilities with radioactive samples. Version 5.0 of the PCT procedure is attached

  9. Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice sets forth requirements to ensure consistency in neutron-induced displacement damage testing of silicon and gallium arsenide electronic piece parts. This requires controls on facility, dosimetry, tester, and communications processes that affect the accuracy and reproducibility of these tests. It provides background information on the technical basis for the requirements and additional recommendations on neutron testing. In addition to neutrons, reactors are used to provide gamma-ray pulses of intensities and durations that are not achievable elsewhere. This practice also provides background information and recommendations on gamma-ray testing of electronics using nuclear reactors. 1.2 Methods are presented for ensuring and validating consistency in neutron displacement damage testing of electronic parts such as integrated circuits, transistors, and diodes. The issues identified and the controls set forth in this practice address the characterization and suitability of the radiation environm...

  10. The ambiguity of standing in standing devices: a qualitative interview study concerning children and parents experiences of the use of standing devices.

    Science.gov (United States)

    Nordström, Birgitta; Näslund, Annika; Ekenberg, Lilly; Zingmark, Karin

    2014-10-01

    The aim of this study was to describe children's and parents' experiences of the significance of standing in a standing device. Individual interviews were performed with six children/teenagers (aged 7-19 years) and 14 parents. The interviews were transcribed and analyzed using a qualitative content analysis. The analysis resulted in the major theme, the duality of uprightness and the related themes: (1) the instrumental dimension of standing; (2) the social dimension of standing; and (3) the ambivalent dimension of standing. Each of the themes comprised several subthemes. There is an inherent duality related to the use of a standing device. Standing in a standing device was seen as a treatment of body structures and functions, as well as a possible source of pain. Standing was considered to influence freedom in activities and participation both positively and negatively. The parents experienced that standing influenced other peoples' views of their child, while the children experienced standing as a way to extend the body and as something that gave them benefits in some activities. Physiotherapists working with children should take into account both the social and physical dimensions of using a standing device and consider both the child's and the parents' views.

  11. Converter-Modulator Design and Operations for the ILC L-band Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Reass, William A.; /Los Alamos; Burkhart, C.; Adolphsen, Chris E.; Beukers, T.; Cassel, R.; de Lira, A.; Papas, C.; Nguyen, M.; Went, R.; /SLAC; Anderson, David E.; /Oak

    2007-09-10

    To facilitate a rapid response to the International Linear Collider (ILC) L-band development program at SLAC, a spare converter-modulator was shipped from LANL. This modulator was to be a spare for the spallation neutron source (SNS) accelerator at ORNL. The ILC application requires a 33% higher peak output power (15 MW) and output current (120 Amp). This presents significant design challenges to modify the existing hardware and yet maintain switching parameters and thermal cycling within the semiconductor component ratings. To minimize IGBT commutation and free-wheeling diode currents, a different set of optimizations, as compared to the SNS design, were used to tune the resonant switching networks. Additional complexities arose as nanocrystalline cores with different performance characteristics (as compared to SNS), were used to fabricate the resonant 'boost' transformers. This paper will describe the electrical design, modeling efforts, and resulting electrical performance as implemented for the ILC L-band test stand.

  12. Initial results for a 170 GHz high power ITER waveguide component test stand

    Science.gov (United States)

    Bigelow, Timothy; Barker, Alan; Dukes, Carl; Killough, Stephen; Kaufman, Michael; White, John; Bell, Gary; Hanson, Greg; Rasmussen, Dave

    2014-10-01

    A high power microwave test stand is being setup at ORNL to enable prototype testing of 170 GHz cw waveguide components being developed for the ITER ECH system. The ITER ECH system will utilize 63.5 mm diameter evacuated corrugated waveguide and will have 24 >150 m long runs. A 170 GHz 1 MW class gyrotron is being developed by Communications and Power Industries and is nearing completion. A HVDC power supply, water-cooling and control system has been partially tested in preparation for arrival of the gyrotron. The power supply and water-cooling system are being designed to operate for >3600 second pulses to simulate the operating conditions planned for the ITER ECH system. The gyrotron Gaussian beam output has a single mirror for focusing into a 63.5 mm corrugated waveguide in the vertical plane. The output beam and mirror are enclosed in an evacuated duct with absorber for stray radiation. Beam alignment with the waveguide is a critical task so a combination of mirror tilt adjustments and a bellows for offsets will be provided. Analysis of thermal patterns on thin witness plates will provide gyrotron mode purity and waveguide coupling efficiency data. Pre-prototype waveguide components and two dummy loads are available for initial operational testing of the gyrotron. ORNL is managed by UT-Battelle, LLC, for the U.S. Dept. of Energy under Contract DE-AC-05-00OR22725.

  13. Procedures for Determining the Performance of Stand-Alone Photovoltaic Systems; TOPICAL

    International Nuclear Information System (INIS)

    DeBlasio, R.; Durand, S.; Hansen, R.; Hutchinson, P.; Kroposki, B.; McNutt, P.; Rosenthal, A.; Thomas, M.

    1999-01-01

    This document provides the procedures for determining the performance of stand-alone PV systems. The procedures in this document provide a common approach for evaluating whether a given PV system is suitable to perform the function for which it was designed and manufactured to accomplish, and whether it will provide adequate power to run the load. These procedures cover small stand-alone PV systems. They cover complete outdoor system testing. Test results are valid only for the system that is tested

  14. Impact of Fibromyalgia in the Sit-to-Stand-to-Sit Performance Compared With Healthy Controls.

    Science.gov (United States)

    Collado-Mateo, Daniel; Adsuar, Jose C; Dominguez-Muñoz, Francisco J; Olivares, Pedro R; Gusi, Narcis

    2017-06-01

    Fibromyalgia is associated with a reduction in the ability to perform activities of daily living. Sit-to-stand-to-sit performance is one of the most common activities of daily living and often is evaluated by counting the number of repetitions of the 30-second chair-stand test. No study, however, has examined the performance over the 30 seconds of this test of female patients with fibromyalgia on a phase-by-phase basis. To evaluate the impact of fibromyalgia on performance of the 30-second chair-stand test and to analyze how the kinematic performance changed over the 30-second test period. A cross-sectional study. Local association of fibromyalgia. Fifteen females with fibromyalgia and nine healthy female controls. Participants performed the 30-second chair-stand test while wearing a motion capture device. Duration of each sit-to-stand-to-sit phase within the 30-second time limit was compared between groups using repeated measures analysis of variance. The association between duration of phases and scores from the revised version of the Fibromyalgia Impact Questionnaire was tested using bivariate correlations. The duration of impulse and sit-to-stand phases were gradually increased over the 30 seconds of the chair-stand test for women with fibromyalgia compared with healthy controls (P = .04 and P = .02, respectively). The mean duration of these 2 phases was associated with symptom duration and the function domain of the revised version of the Fibromyalgia Impact Questionnaire (P fibromyalgia and healthy controls. Since sit-to-stand from a chair is a common daily activity, women with fibromyalgia may require specific exercises to improve performance of this task. Not applicable. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  15. Stand and within-stand factors influencing Golden-winged Warbler use of regenerating stands in the central Appalachian Mountains

    Directory of Open Access Journals (Sweden)

    Marja H. Bakermans

    2015-06-01

    Full Text Available The Golden-winged Warbler (Vermivora chrysoptera is currently being considered for protected status under the U.S. Endangered Species Act. The creation of breeding habitat in the Appalachian Mountains is considered a conservation priority for this songbird, which is dependent on extensively forested landscapes with adequate availability of young forest. We modeled abundance of Golden-winged Warbler males in regenerating harvested forest stands that were 0-17 years postharvest at both mid-Appalachian and northeast Pennsylvania regional scales using stand and within-stand characteristics of 222 regenerating stands, 2010-2011. Variables that were most influential at the mid-Appalachian scale were different than those in the northeast region. Across the mid-Appalachian ecoregion, the proportion of young forest cover, i.e., shrub/scrub cover, within 1 km of regenerating stands best explained abundance of Golden-winged Warblers. Golden-winged Warbler response was best explained by a concave quadratic relationship in which abundance was highest with 5-15% land in young forest cover. We also found evidence that the amount of herbaceous cover, i.e., the amount of grasses and forbs, within a regenerating stand positively influenced abundance of Golden-winged Warblers. In northeastern Pennsylvania, where young forest cover is found in high proportions, the distance to the nearest regenerating stand best explained variation in abundance of Golden-winged Warblers. Abundance of Golden-winged Warblers was 1500 m away. When modeling within-stand features in the northeast region, many of the models were closely ranked, indicating that multiple variables likely explained Golden-winged Warbler response to within-stand conditions. Based on our findings, we have proposed several management guidelines for land managers interested in creating breeding habitat for Golden-winged Warblers using commercial timber operations. For example, we recommend when managing for

  16. The 1-Minute Sit-to-Stand Test in Adults With Cystic Fibrosis: Correlations With Cardiopulmonary Exercise Test, 6-Minute Walk Test, and Quadriceps Strength.

    Science.gov (United States)

    Gruet, Mathieu; Peyré-Tartaruga, Leonardo Alexandre; Mely, Laurent; Vallier, Jean-Marc

    2016-12-01

    Exercise testing is part of the regular assessment of patients with cystic fibrosis (CF). We aimed to evaluate (1) the convergent validity of the 1-min sit-to-stand (STS) test in CF by investigating its relationships with peak oxygen uptake (peak V̇ O 2 ), quadriceps strength, and quality of life and (2) to compare these associations with those of the 6-min walk test (6MWT). Twenty-five adults with CF (FEV 1 = 59 ± 24%) performed the STS test, the 6MWT, quadriceps strength assessment, and cardiopulmonary exercise test (CPET). Physical activity level, quality of life, and self-esteem were assessed by questionnaires. STS repetitions, 6-min walk distance, quadriceps strength, and peak V̇ O 2 were, respectively, 71 ± 12, 90 ± 10, 93 ± 29, and 62 ± 16% of predicted. The STS test had moderate associations with peak V̇ O 2 (r = 0.56, P = .004), quadriceps strength (r = 0.52, P = .008), and some questionnaire items (eg, perceived physical strength, r = 0.67, P test was strongly associated with oxygen desaturation during CPET (r = 0.80, P test as compared with CPET (P test cannot be used as a replacement for CPET to accurately assess peak exercise capacity in CF. The STS test may have utility in detecting patients with CF who may exhibit a high level of oxygen desaturation during heavy exercise. Further studies should identify the factors contributing to STS performance to confirm the potential interest of STS repetitions × body weight outcome as a useful submaximal exercise parameter in CF. Copyright © 2016 by Daedalus Enterprises.

  17. Tilt table standing for reducing spasticity after spinal cord injury.

    Science.gov (United States)

    Bohannon, R W

    1993-10-01

    A patient with a T12 spinal cord injury and intractable extensor spasms of the lower extremities participated in tilt table standing trial on 5 nonconsecutive days to determine if the intervention would affect his spasticity and spasms. Each day's standing trial was followed by an immediate reduction in lower extremity spasticity (measured using the modified Ashworth scale and pendulum testing). Standing was also accompanied by a reduction in spasms that lasted until the following morning. The reduction of spasms was particularly advantageous to the performance of car transfers. Tilt table standing merits further examination as a physical treatment of spasms that accompany central nervous system lesions.

  18. Preferences for HIV test characteristics among young, Black Men Who Have Sex With Men (MSM) and transgender women: Implications for consistent HIV testing

    Science.gov (United States)

    Frye, Victoria; Hirshfield, Sabina; Chiasson, Mary Ann; Lucy, Debbie; Usher, DaShawn; McCrossin, Jermaine; Greene, Emily; Koblin, Beryl

    2018-01-01

    Background Promoting consistent HIV testing is critical among young, Black Men Who Have Sex With Men (MSM) and transgender women who are overrepresented among new HIV cases in the United States. New HIV test options are available, including mobile unit testing, one-minute testing, at home or self-testing and couples HIV testing and counseling (CHTC). In the context of these newer options, the objective of this study was to explore whether and how preferences for specific characteristics of the tests acted as barriers to and/or facilitators of testing in general and consistent testing specifically among young Black MSM and transgender women aged 16 to 29. Methods We conducted 30 qualitative, semi-structured, in-depth interviews with young, Black, gay, bisexual or MSM and transgender women in the New York City metropolitan area to identify preferences for specific HIV tests and aspects of HIV testing options. Participants were primarily recruited from online and mobile sites, followed by community-based, face-to-face recruitment strategies to specifically reach younger participants. Thematic coding was utilized to analyze the qualitative data based on a grounded theoretical approach. Results We identified how past experiences, perceived test characteristics (e.g., accuracy, cost, etc.) and beliefs about the “fit” between the individual, and the test relate to preferred testing methods and consistent testing. Three major themes emerged as important to preferences for HIV testing methods: the perceived accuracy of the test method, venue characteristics, and lack of knowledge or experience with the newer testing options, including self-testing and CHTC. Conclusions These findings suggest that increasing awareness of and access to newer HIV testing options (e.g., free or reduced price on home or self-tests or CHTC available at all testing venues) is critical if these new options are to facilitate increased levels of consistent testing among young, Black MSM and

  19. Preferences for HIV test characteristics among young, Black Men Who Have Sex With Men (MSM) and transgender women: Implications for consistent HIV testing.

    Science.gov (United States)

    Frye, Victoria; Wilton, Leo; Hirshfield, Sabina; Chiasson, Mary Ann; Lucy, Debbie; Usher, DaShawn; McCrossin, Jermaine; Greene, Emily; Koblin, Beryl

    2018-01-01

    Promoting consistent HIV testing is critical among young, Black Men Who Have Sex With Men (MSM) and transgender women who are overrepresented among new HIV cases in the United States. New HIV test options are available, including mobile unit testing, one-minute testing, at home or self-testing and couples HIV testing and counseling (CHTC). In the context of these newer options, the objective of this study was to explore whether and how preferences for specific characteristics of the tests acted as barriers to and/or facilitators of testing in general and consistent testing specifically among young Black MSM and transgender women aged 16 to 29. We conducted 30 qualitative, semi-structured, in-depth interviews with young, Black, gay, bisexual or MSM and transgender women in the New York City metropolitan area to identify preferences for specific HIV tests and aspects of HIV testing options. Participants were primarily recruited from online and mobile sites, followed by community-based, face-to-face recruitment strategies to specifically reach younger participants. Thematic coding was utilized to analyze the qualitative data based on a grounded theoretical approach. We identified how past experiences, perceived test characteristics (e.g., accuracy, cost, etc.) and beliefs about the "fit" between the individual, and the test relate to preferred testing methods and consistent testing. Three major themes emerged as important to preferences for HIV testing methods: the perceived accuracy of the test method, venue characteristics, and lack of knowledge or experience with the newer testing options, including self-testing and CHTC. These findings suggest that increasing awareness of and access to newer HIV testing options (e.g., free or reduced price on home or self-tests or CHTC available at all testing venues) is critical if these new options are to facilitate increased levels of consistent testing among young, Black MSM and transgender women. Addressing perceptions of

  20. Preferences for HIV test characteristics among young, Black Men Who Have Sex With Men (MSM and transgender women: Implications for consistent HIV testing.

    Directory of Open Access Journals (Sweden)

    Victoria Frye

    Full Text Available Promoting consistent HIV testing is critical among young, Black Men Who Have Sex With Men (MSM and transgender women who are overrepresented among new HIV cases in the United States. New HIV test options are available, including mobile unit testing, one-minute testing, at home or self-testing and couples HIV testing and counseling (CHTC. In the context of these newer options, the objective of this study was to explore whether and how preferences for specific characteristics of the tests acted as barriers to and/or facilitators of testing in general and consistent testing specifically among young Black MSM and transgender women aged 16 to 29.We conducted 30 qualitative, semi-structured, in-depth interviews with young, Black, gay, bisexual or MSM and transgender women in the New York City metropolitan area to identify preferences for specific HIV tests and aspects of HIV testing options. Participants were primarily recruited from online and mobile sites, followed by community-based, face-to-face recruitment strategies to specifically reach younger participants. Thematic coding was utilized to analyze the qualitative data based on a grounded theoretical approach.We identified how past experiences, perceived test characteristics (e.g., accuracy, cost, etc. and beliefs about the "fit" between the individual, and the test relate to preferred testing methods and consistent testing. Three major themes emerged as important to preferences for HIV testing methods: the perceived accuracy of the test method, venue characteristics, and lack of knowledge or experience with the newer testing options, including self-testing and CHTC.These findings suggest that increasing awareness of and access to newer HIV testing options (e.g., free or reduced price on home or self-tests or CHTC available at all testing venues is critical if these new options are to facilitate increased levels of consistent testing among young, Black MSM and transgender women. Addressing

  1. Stand-Alone Containment Analysis of the Phébus FPT Tests with the ASTEC and the MELCOR Codes: The FPT-0 Test

    Directory of Open Access Journals (Sweden)

    Bruno Gonfiotti

    2017-01-01

    Full Text Available The integral Phébus tests were probably one of the most important experimental campaigns performed to investigate the progression of severe accidents in light water reactors. In these tests, the degradation of a PWR fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the results of such tests, numerical codes such as ASTEC and MELCOR have been developed to describe the evolution of a severe accident. After the termination of the experimental Phébus campaign, these two codes were furthermore expanded. Therefore, the aim of the present work is to reanalyze the first Phébus test (FPT-0 employing the updated ASTEC and MELCOR versions to ensure that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The analysis focuses on the stand-alone containment aspects of this test, and the paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products behavior. This paper is part of a series of publications covering the four executed Phébus tests employing a solid PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3.

  2. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, ptest-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

    Energy Technology Data Exchange (ETDEWEB)

    Antoni, V.; Agostinetti, P.; Brombin, M.; Cervaro, V.; Delogu, R.; Fasolo, D.; Franchin, L.; Ghiraldelli, R.; Molon, F.; Pasqualotto, R.; Serianni, G., E-mail: gianluigi.serianni@igi.cnr.it; Tollin, M.; Veltri, P. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) (Italy); De Muri, M. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) (Italy); INFN-LNL, v.le dell' Università 2, I-35020, Legnaro (PD) Italy (Italy); Ikeda, K.; Kisaki, M.; Nakano, H.; Takeiri, Y.; Tsumori, K. [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Muraro, A. [Istituto di Fisica del Plasma (IFP-CNR) – Via Cozzi 53, 20125, Milano (Italy)

    2015-04-08

    In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

  4. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1989-01-01

    The Product Consistency Test (PCT) is a glass leach test that was developed at the Savannah River Site (SRS) to routinely confirm the durability of nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a 7 day, crushed glass leach test in deionized water at 90 degree C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2--5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment

  5. Remaining useful life prediction based on variation coefficient consistency test of a Wiener process

    Directory of Open Access Journals (Sweden)

    Juan LI

    2018-01-01

    Full Text Available High-cost equipment is often reused after maintenance, and whether the information before the maintenance can be used for the Remaining Useful Life (RUL prediction after the maintenance is directly determined by the consistency of the degradation pattern before and after the maintenance. Aiming at this problem, an RUL prediction method based on the consistency test of a Wiener process is proposed. Firstly, the parameters of the Wiener process estimated by Maximum Likelihood Estimation (MLE are proved to be biased, and a modified unbiased estimation method is proposed and verified by derivation and simulations. Then, the h statistic is constructed according to the reciprocal of the variation coefficient of the Wiener process, and the sampling distribution is derived. Meanwhile, a universal method for the consistency test is proposed based on the sampling distribution theorem, which is verified by simulation data and classical crack degradation data. Finally, based on the consistency test of the degradation model, a weighted fusion RUL prediction method is presented for the fuel pump of an airplane, and the validity of the presented method is verified by accurate computation results of real data, which provides a theoretical and practical guidance for engineers to predict the RUL of equipment after maintenance.

  6. Sitting and standing blood pressure measurements are not accurate for the diagnosis of orthostatic hypotension.

    LENUS (Irish Health Repository)

    Cooke, J

    2012-01-31

    INTRODUCTION: Orthostatic hypotension (OH) is associated with troublesome symptoms and increased mortality. It is treatable and deserving of accurate diagnosis. This can be time consuming. The current reference standard for its diagnosis is head-up tilt (HUT) testing with continuous beat-to-beat plethysmography. Our objective was to assess the accuracy of sit-stand testing with semi-automatic sphygmomanometry for the diagnosis of OH. DESIGN: Retrospective test of diagnostic accuracy. METHODS: This was a retrospective study performed using a database maintained by a busy syncope unit. HUT testing was performed using an automated tilt table with Finometer monitoring. A 3 min 70 degrees HUT was performed following 5 min supine. Sitting blood pressure (BP) was measured following 3 min rest. Standing BP was measured within 30 s of assuming the upright posture. The results of sit-stand testing were compared with HUT testing as a reference standard. Both tests happened within 5 min of each other and patients underwent no intervention between tests. RESULTS: From a total of 1452 consecutive HUTs, we identified 730 with pre-test measures of sitting and standing BP. The mean age of this group was 70.57 years (SD = 15.1), 62% were female. The sensitivity of sit-stand testing was calculated as 15.5%, specificity as 89.9%, positive predictive value as 61.7%, negative predictive value as 50.2% and the likelihood ratio as 1.6. The area under the Receiver Operator Curve was 0.564. CONCLUSION: We have demonstrated that sit-stand testing for OH has very low diagnostic accuracy. We recommend that the more time-consuming reference standard method of diagnosis be used if the condition is suspected.

  7. Compressor Load Stand: Commissioning and Control Strategies

    National Research Council Canada - National Science Library

    Causey, Andrew

    1998-01-01

    .... The purpose of this research project was to commission this load stand, which includes setting up the hardware, setting up a control system, a data acquisition system, and an automatic test sequence system...

  8. ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, R A; Anderson, S G; Barty, C P; Chu, T S; Ebbers, C A; Gibson, D J; Hartemann, F V; Adolphsen, C; Jongewaard, E N; Raubenheimer, T; Tantawi, S G; Vlieks, A E; Wang, J W

    2010-05-12

    In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

  9. Regional Instability in the Abundance of Open Stands in the Boreal Forest of Eastern Canada

    Directory of Open Access Journals (Sweden)

    Rija Rapanoela

    2016-05-01

    Full Text Available Fires are a key disturbance of boreal forests. In fact, they are the main source of renewal and evolution for forest stands. The variability of fire through space and time results in a diversified forest mosaic, altering their species composition, structure and productivity. A resilient forest is assumed to be in a state of dynamic equilibrium with the fire regime, so that the composition, age structure and succession stages of forests should be consistent with the fire regime. Dense spruce-moss stands tend, however, to diminish in favour of more open stands similar to spruce-lichen stands when subjected to more frequent and recurring disturbances. This study therefore focused on the effects of spatial and temporal variations in burn rates on the proportion of open stands over a large geographic area (175,000 km2 covered by black spruce (Picea mariana (Mill. Britton, Sterns, Poggenb.. The study area was divided into 10 different zones according to burn rates, as measured using fire-related data collected between 1940 and 2006. To test if the abundance of open stands was unstable over time and not in equilibrium with the current fire regime, forest succession was simulated using a landscape dynamics model that showed that the abundance of open stands should increase progressively over time in zones where the average burn rate is high. The proportion of open stands generated during a specific historical period is correlated with the burn rate observed during the same period. Rising annual burn rates over the past two decades have thereby resulted in an immediate increase in the proportion of open stands. There is therefore a difference between the current proportion of open stands and the one expected if vegetation was in equilibrium with the disturbance regime, reflecting an instability that may significantly impact the way forest resources are managed. It is apparent from this study that forestry planning should consider the risks associated

  10. Cryogenic infrastructure for Fermilab's ILC vertical cavity test facility

    International Nuclear Information System (INIS)

    Carcagno, R.; Ginsburg, C.; Huang, Y.; Norris, B.; Ozelis, J.; Peterson, T.; Poloubotko, V.; Rabehl, R.; Sylvester, C.; Wong, M.; Fermilab

    2006-01-01

    Fermilab is building a Vertical Cavity Test Facility (VCTF) to provide for R and D and pre-production testing of bare 9-cell, 1.3-GHz superconducting RF (SRF) cavities for the International Linear Collider (ILC) program. This facility is located in the existing Industrial Building 1 (IB1) where the Magnet Test Facility (MTF) also resides. Helium and nitrogen cryogenics are shared between the VCTF and MTF including the existing 1500-W at 4.5-K helium refrigerator with vacuum pumping for super-fluid operation (125-W capacity at 2-K). The VCTF is being constructed in multiple phases. The first phase is scheduled for completion in mid 2007, and includes modifications to the IB1 cryogenic infrastructure to allow helium cooling to be directed to either the VCTF or MTF as scheduling demands require. At this stage, the VCTF consists of one Vertical Test Stand (VTS) cryostat for the testing of one cavity in a 2-K helium bath. Planning is underway to provide a total of three Vertical Test Stands at VCTF, each capable of accommodating two cavities. Cryogenic infrastructure improvements necessary to support these additional VCTF test stands include a dedicated ambient temperature vacuum pump, a new helium purification skid, and the addition of helium gas storage. This paper describes the system design and initial cryogenic operation results for the first VCTF phase, and outlines future cryogenic infrastructure upgrade plans for expanding to three Vertical Test Stands

  11. CRYOGENIC INFRASTRUCTURE FOR FERMILAB'S ILC VERTICAL CAVITY TEST FACILITY

    International Nuclear Information System (INIS)

    Carcagno, R.; Ginsburg, C.; Huang, Y.; Norris, B.; Ozelis, J.; Peterson, T.; Poloubotko, V.; Rabehl, R.; Sylvester, C.; Wong, M.

    2008-01-01

    Fermilab is building a Vertical Cavity Test Facility (VCTF) to provide for R and D and pre-production testing of bare 9-cell, 1.3-GHz superconducting RF (SRF) cavities for the International Linear Collider (ILC) program. This facility is located in the existing Industrial Building 1 (IB1) where the Magnet Test Facility (MTF) also resides. Helium and nitrogen cryogenics are shared between the VCTF and MTF including the existing 1500-W at 4.5-K helium refrigerator with vacuum pumping for super-fluid operation (125-W capacity at 2-K). The VCTF is being constructed in multiple phases. The first phase is scheduled for completion in mid 2007, and includes modifications to the IB1 cryogenic infrastructure to allow helium cooling to be directed to either the VCTF or MTF as scheduling demands require. At this stage, the VCTF consists of one Vertical Test Stand (VTS) cryostat for the testing of one cavity in a 2-K helium bath. Planning is underway to provide a total of three Vertical Test Stands at VCTF, each capable of accommodating two cavities. Cryogenic infrastructure improvements necessary to support these additional VCTF test stands include a dedicated ambient temperature vacuum pump, a new helium purification skid, and the addition of helium gas storage. This paper describes the system design and initial cryogenic operation results for the first VCTF phase, and outlines future cryogenic infrastructure upgrade plans for expanding to three Vertical Test Stands

  12. Isotope enrichment effect of gaseous mixtures in standing sound vibration

    International Nuclear Information System (INIS)

    Knesebeck, R.L.

    1984-01-01

    When standing acoustic waves are excited in a tube containing a mixture of two gases, a partial zonal fractioning of the components arises as consequence of mass transport by diffusion, driven by the thermal and pressure gradients which are associeted with the standing waves. This effect is present in each zone corresponding to a quarter wavelength, with the heavier component becoming enriched at the nodes fo the standing waves and deplected at the crests. The magnitude of the enrichment in one of the components of a binary gas mixture is given by Δω=ap 2 /lambda [b + (1-bω)] 2 . Where ω is the mass concentration of the component in the mixture, a and b are parameters which are related to molecular proprieties of the gases, p is the relative pressure amplitude of the standing wave and lambda is its wavelength. For a natural mixture of uranium hexafluorate, with 0.715% of the uranium isotope 340 an enrichment of about 2 x 10 -6 % in the concentration of this isotope is theorecticaly attainable per stage consisting of a quarter wavelenght, when a standing acoustical wave of relative pressure amplitude of 0,2 and wavelenght of 20 cm is used. Since standing acoustical waves are easely excited in gas columns, an isotope enrichment plant made of a cascade of tubes in which standing waves are excited, is presumably feasible with relatively low investment and operation costs. (Author) [pt

  13. Testing the visual consistency of web sites

    NARCIS (Netherlands)

    van der Geest, Thea; Loorbach, N.R.

    2005-01-01

    Consistency in the visual appearance of Web pages is often checked by experts, such as designers or reviewers. This article reports a card sort study conducted to determine whether users rather than experts could distinguish visual (in-)consistency in Web elements and pages. The users proved to

  14. U.S. Army Physical Demands Study: Development of the Occupational Physical Assessment Test for Combat Arms soldiers.

    Science.gov (United States)

    Foulis, Stephen A; Sharp, Marilyn A; Redmond, Jan E; Frykman, Peter N; Warr, Bradley J; Gebhardt, Deborah L; Baker, Todd A; Canino, Maria C; Zambraski, Edward J

    2017-11-01

    The United States Army sought to create a legally defensible, scientifically validated physical pre-employment screening test. The purpose of this study was to identify a single combination of predictor tests that would predict physical performance on all of the criterion measure task simulations relevant to the Combat Arms military occupational specialties. Concurrent validation. Data from 838 (608 males, 230 females) soldiers who completed both the criterion measure task simulations of a military occupational specialty and up to 14 predictor tests were used in the development of the test batteries. Stepwise regressions were used to identify test batteries that significantly predicted performance on the criterion measure task simulations of the military occupational specialties. Three test batteries were developed based on different subsets of the predictor tests: Test Battery 1 consisted of the medicine ball put, squat lift, beep test, standing long jump, and arm ergometer (adjusted R 2 =0.80-0.85, pTest Battery 2 consisted of the medicine ball put, squat lift, beep test, and standing long jump (adjusted R 2 =0.79-0.80, pTest Battery 3 consisted of the standing long jump, 1-minute push-ups, 1-minute sit-ups, 300m sprint, and Illinois agility test (adjusted R 2 =0.55-0.71, pTest Battery 2 was selected as the Army's Occupational Physical Assessment Test. It was highly predictive of performance of the Combat Arms military occupational specialties, required no complex equipment, and covered a range of physical fitness domains. Published by Elsevier Ltd.

  15. Which is preferable for orthostatic hypotension diagnosis in older adults: active standing test or head-up tilt table test?

    Science.gov (United States)

    Aydin, Ali Ekrem; Soysal, Pinar; Isik, Ahmet Turan

    2017-01-01

    Correct evaluation of orthostatic hypotension (OH) is crucial in geriatric practice, since OH is associated with mortality and morbidity. The study aimed to determine the most appropriate method for measuring blood pressure in transition from supine to upright position in order to diagnose OH in older adults. Active standing test (AST) and head-up tilt table (HUT) test as well as comprehensive geriatric assessment (CGA), including mini-mental state examination or the cognitive state test, mini-nutritional assessment, basic and instrumental activities of daily living, and Tinetti performance-oriented mobility assessment indexes, were performed in 290 geriatric patients. The prevalence of OH during HUT and AST was 19% and 37%, respectively. In patients with OH during HUT, the frequency of dementia and recurrent falls were higher ( P 0.05). Comparison of the groups according to CGA measurements revealed significant differences in terms of cognition, nutritional status, activities of daily life, and balance function in patients with OH only during HUT ( P 0.05). The sensitivity, specificity, positive predictive value, and negative predictive values of AST were 49.0%, 65.5%, 25.0%, and 84.6% respectively, according to HUT. The results suggest that orthostatic blood pressure changes determined by HUT might be of higher clinical significance than that by AST in older adults. It might be important that the evaluation of OH by HUT should be included in daily geriatric practice.

  16. Standing wave accelerating structures

    International Nuclear Information System (INIS)

    Zavadtsev, A.A.; Zverev, B.V.; Sobepin, N.P.

    1984-01-01

    Accelerating ELA structures are considered and chosen for applied purposes of special designation. Accelerating structures with the standing wave are considered most effective for small size ELA. Designs and results of experimental investigation of two new accelerating structures are described. These are structures of the ''ring'' type with a decreased number of excitinq oscillation types and strucuture with transverse rods with a twice smaller transverse size as compared with the biperiodical structure with internal connection resonators. The accelerating biperiodical structures of the conventional type by the fact that the whole structure is not a linear chain of connected resonators, but a ring one. Model tests have shown that the homogeneous structure with transverse rods (STR) at the frequency of 2.8 GHz in the regime of the standing wave has an effective shunt resistance equalling 23 MOhm/m. It is shown that the small transverse size of biperiodic STR makes its application in logging linear electron accelerators

  17. Radiometric Correction of Multitemporal Hyperspectral Uas Image Mosaics of Seedling Stands

    Science.gov (United States)

    Markelin, L.; Honkavaara, E.; Näsi, R.; Viljanen, N.; Rosnell, T.; Hakala, T.; Vastaranta, M.; Koivisto, T.; Holopainen, M.

    2017-10-01

    Novel miniaturized multi- and hyperspectral imaging sensors on board of unmanned aerial vehicles have recently shown great potential in various environmental monitoring and measuring tasks such as precision agriculture and forest management. These systems can be used to collect dense 3D point clouds and spectral information over small areas such as single forest stands or sample plots. Accurate radiometric processing and atmospheric correction is required when data sets from different dates and sensors, collected in varying illumination conditions, are combined. Performance of novel radiometric block adjustment method, developed at Finnish Geospatial Research Institute, is evaluated with multitemporal hyperspectral data set of seedling stands collected during spring and summer 2016. Illumination conditions during campaigns varied from bright to overcast. We use two different methods to produce homogenous image mosaics and hyperspectral point clouds: image-wise relative correction and image-wise relative correction with BRDF. Radiometric datasets are converted to reflectance using reference panels and changes in reflectance spectra is analysed. Tested methods improved image mosaic homogeneity by 5 % to 25 %. Results show that the evaluated method can produce consistent reflectance mosaics and reflectance spectra shape between different areas and dates.

  18. RADIOMETRIC CORRECTION OF MULTITEMPORAL HYPERSPECTRAL UAS IMAGE MOSAICS OF SEEDLING STANDS

    Directory of Open Access Journals (Sweden)

    L. Markelin

    2017-10-01

    Full Text Available Novel miniaturized multi- and hyperspectral imaging sensors on board of unmanned aerial vehicles have recently shown great potential in various environmental monitoring and measuring tasks such as precision agriculture and forest management. These systems can be used to collect dense 3D point clouds and spectral information over small areas such as single forest stands or sample plots. Accurate radiometric processing and atmospheric correction is required when data sets from different dates and sensors, collected in varying illumination conditions, are combined. Performance of novel radiometric block adjustment method, developed at Finnish Geospatial Research Institute, is evaluated with multitemporal hyperspectral data set of seedling stands collected during spring and summer 2016. Illumination conditions during campaigns varied from bright to overcast. We use two different methods to produce homogenous image mosaics and hyperspectral point clouds: image-wise relative correction and image-wise relative correction with BRDF. Radiometric datasets are converted to reflectance using reference panels and changes in reflectance spectra is analysed. Tested methods improved image mosaic homogeneity by 5 % to 25 %. Results show that the evaluated method can produce consistent reflectance mosaics and reflectance spectra shape between different areas and dates.

  19. Validation of the VitaBit Sit–Stand Tracker: Detecting Sitting, Standing, and Activity Patterns

    Directory of Open Access Journals (Sweden)

    Nathalie M. Berninger

    2018-03-01

    Full Text Available Sedentary behavior (SB has detrimental consequences and cannot be compensated for through moderate-to-vigorous physical activity (PA. In order to understand and mitigate SB, tools for measuring and monitoring SB are essential. While current direct-to-customer wearables focus on PA, the VitaBit validated in this study was developed to focus on SB. It was tested in a laboratory and in a free-living condition, comparing it to direct observation and to a current best-practice device, the ActiGraph, on a minute-by-minute basis. In the laboratory, the VitaBit yielded specificity and negative predictive rates (NPR of above 91.2% for sitting and standing, while sensitivity and precision ranged from 74.6% to 85.7%. For walking, all performance values exceeded 97.3%. In the free-living condition, the device revealed performance of over 72.6% for sitting with the ActiGraph as criterion. While sensitivity and precision for standing and walking ranged from 48.2% to 68.7%, specificity and NPR exceeded 83.9%. According to the laboratory findings, high performance for sitting, standing, and walking makes the VitaBit eligible for SB monitoring. As the results are not transferrable to daily life activities, a direct observation study in a free-living setting is recommended.

  20. Requirements for UML and OWL Integration Tool for User Data Consistency Modeling and Testing

    DEFF Research Database (Denmark)

    Nytun, J. P.; Jensen, Christian Søndergaard; Oleshchuk, V. A.

    2003-01-01

    The amount of data available on the Internet is continuously increasing, consequentially there is a growing need for tools that help to analyse the data. Testing of consistency among data received from different sources is made difficult by the number of different languages and schemas being used....... In this paper we analyze requirements for a tool that support integration of UML models and ontologies written in languages like the W3C Web Ontology Language (OWL). The tool can be used in the following way: after loading two legacy models into the tool, the tool user connects them by inserting modeling......, an important part of this technique is attaching of OCL expressions to special boolean class attributes that we call consistency attributes. The resulting integration model can be used for automatic consistency testing of two instances of the legacy models by automatically instantiate the whole integration...

  1. Modular high-throughput test stand for versatile screening of thin-film materials libraries

    International Nuclear Information System (INIS)

    Thienhaus, Sigurd; Hamann, Sven; Ludwig, Alfred

    2011-01-01

    Versatile high-throughput characterization tools are required for the development of new materials using combinatorial techniques. Here, we describe a modular, high-throughput test stand for the screening of thin-film materials libraries, which can carry out automated electrical, magnetic and magnetoresistance measurements in the temperature range of −40 to 300 °C. As a proof of concept, we measured the temperature-dependent resistance of Fe–Pd–Mn ferromagnetic shape-memory alloy materials libraries, revealing reversible martensitic transformations and the associated transformation temperatures. Magneto-optical screening measurements of a materials library identify ferromagnetic samples, whereas resistivity maps support the discovery of new phases. A distance sensor in the same setup allows stress measurements in materials libraries deposited on cantilever arrays. A combination of these methods offers a fast and reliable high-throughput characterization technology for searching for new materials. Using this approach, a composition region has been identified in the Fe–Pd–Mn system that combines ferromagnetism and martensitic transformation.

  2. Test stand for non-uniformity correction of microbolometer focal plane arrays used in thermal cameras

    Science.gov (United States)

    Krupiński, Michał; Bareła, Jaroslaw; Firmanty, Krzysztof; Kastek, Mariusz

    2013-10-01

    Uneven response of particular detectors (pixels) to the same incident power of infrared radiation is an inherent feature of microbolometer focal plane arrays. As a result an image degradation occurs, known as Fixed Pattern Noise (FPN), which distorts the thermal representation of an observed scene and impairs the parameters of a thermal camera. In order to compensate such non-uniformity, several NUC correction methods are applied in digital data processing modules implemented in thermal cameras. Coefficients required to perform the non-uniformity correction procedure (NUC coefficients) are determined by calibrating the camera against uniform radiation sources (blackbodies). Non-uniformity correction is performed in a digital processing unit in order to remove FPN pattern in the registered thermal images. Relevant correction coefficients are calculated on the basis of recorded detector responses to several values of radiant flux emitted from reference IR radiation sources (blackbodies). The measurement of correction coefficients requires specialized setup, in which uniform, extended radiation sources with high temperature stability are one of key elements. Measurement stand for NUC correction developed in Institute of Optoelectronics, MUT, comprises two integrated extended blackbodies with the following specifications: area 200×200 mm, stabilized absolute temperature range +15 °C÷100 °C, and uniformity of temperature distribution across entire surface +/-0.014 °C. Test stand, method used for the measurement of NUC coefficients and the results obtained during the measurements conducted on a prototype thermal camera will be presented in the paper.

  3. Online retrieval of patient information by asynchronous communication between general purpose computer and stand-alone personal computer

    International Nuclear Information System (INIS)

    Tsutsumi, Reiko; Takahashi, Kazuei; Sato, Toshiko; Komatani, Akio; Yamaguchi, Koichi

    1988-01-01

    Asynchronous communication was made between host (FACOM M-340) and personal computer (OLIBETTIE S-2250) to get patient's information required for RIA test registration. The retrieval system consists of a keyboad input of six numeric codes, patient's ID, and a real time reply containing six parameters for the patient. Their identified parameters are patient's name, sex, date of birth (include area), department, and out- or inpatient. Linking this program to RIA registration program for individual patient, then, operator can input name of RIA test requested. Our simple retrieval program made a useful data network between different types of host and stand-alone personal computers, and enabled us accurate and labor-saving registration for RIA test. (author)

  4. A whole stand growth and yield system for young longleaf pine plantations in Southwest Georgia

    Science.gov (United States)

    John R. Brooks; Steven B. Jack

    2006-01-01

    A whole stand growth and yield system for planted longleaf pine (Pinus palustris Mill.) was developed from permanent plot data collected annually over an 8 year period. The dataset consists of 12 intensively-managed longleaf pine plantations that are located in Lee, Worth, Mitchell, and Baker counties in southwest Georgia. Stand survival, dominant...

  5. Force Concept Inventory-based multiple-choice test for investigating students’ representational consistency

    Directory of Open Access Journals (Sweden)

    Pasi Nieminen

    2010-08-01

    Full Text Available This study investigates students’ ability to interpret multiple representations consistently (i.e., representational consistency in the context of the force concept. For this purpose we developed the Representational Variant of the Force Concept Inventory (R-FCI, which makes use of nine items from the 1995 version of the Force Concept Inventory (FCI. These original FCI items were redesigned using various representations (such as motion map, vectorial and graphical, yielding 27 multiple-choice items concerning four central concepts underpinning the force concept: Newton’s first, second, and third laws, and gravitation. We provide some evidence for the validity and reliability of the R-FCI; this analysis is limited to the student population of one Finnish high school. The students took the R-FCI at the beginning and at the end of their first high school physics course. We found that students’ (n=168 representational consistency (whether scientifically correct or not varied considerably depending on the concept. On average, representational consistency and scientifically correct understanding increased during the instruction, although in the post-test only a few students performed consistently both in terms of representations and scientifically correct understanding. We also compared students’ (n=87 results of the R-FCI and the FCI, and found that they correlated quite well.

  6. Modeling, Design and Simulation of Stand-Alone Photovoltaic Power Systems with Battery Storage

    Directory of Open Access Journals (Sweden)

    Abd Essalam BADOUD

    2013-06-01

    Full Text Available Stand alone renewable energy based on photovoltaic systems accompanied with battery storage system are beginning to play an important role over the world to supply power to remote areas. The objective of the study reported in this paper is to elaborate and design a bond graphs model for sizing stand-alone domestic solar photovoltaic electricity systems and simulating the performance of the systems in a tropical climate. The systems modelled consist of an array of PV modules, a lead-acid battery, and a number of direct current appliances. This paper proposes the combination of lead acid battery system with a typical stand alone photovoltaic energy system under variable loads. The main activities of this work purpose to establish library graphical models for each individual component of standalone photovoltaic system. Control strategy has been considered to achieve permanent power supply to the load via photovoltaic/battery based on the power available from the sun. The complete model was simulated under two testing including sunny and cloudy conditions. Simulation of the system using Symbols software was performed and the results of simulation show the superior stable control system and high efficiency. These results have been contrasted with real measured data from a measurement campaign plant carried on electrical engineering laboratory of Grenoble using various interconnection schemes are presented.

  7. Putting humans in ecology: consistency in science and management.

    Science.gov (United States)

    Hobbs, Larry; Fowler, Charles W

    2008-03-01

    Normal and abnormal levels of human participation in ecosystems can be revealed through the use of macro-ecological patterns. Such patterns also provide consistent and objective guidance that will lead to achieving and maintaining ecosystem health and sustainability. This paper focuses on the consistency of this type of guidance and management. Such management, in sharp contrast to current management practices, ensures that our actions as individuals, institutions, political groups, societies, and as a species are applied consistently across all temporal, spatial, and organizational scales. This approach supplants management of today, where inconsistency results from debate, politics, and legal and religious polarity. Consistency is achieved when human endeavors are guided by natural patterns. Pattern-based management meets long-standing demands for enlightened management that requires humans to participate in complex systems in consistent and sustainable ways.

  8. Test stand for magnetron H negative ion source at IPP-Nagoya

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, H; Kuroda, T; Miyahara, A

    1981-02-01

    Test facilities for the development of magnetron H(-) ion source consists of the vacuum system, power supplies, diagnostic equipment, and their controlling electronics. Schematics are presented and relevant items described including sequence control, optical links, the charged pulse forming network, the extractor power supply, magnet power supply, temperature control of the cesium feeder, and the pulsed valve driver. Noise problems and diagnostics are also considered.

  9. Feasibility of progressive sit-to-stand training among older hospitalized patients

    DEFF Research Database (Denmark)

    Pedersen, Mette Merete; Petersen, Janne; Bean, Jonathan F

    2015-01-01

    hospitalization and once following discharge in their own homes. A structured interview including assessment of possible modifiers (cognitive status by the Short Orientation Memory test and mobility by the De Morton Mobility Index) was administered both on admission to the hospital and in the home setting...... was independent of cognitive status. Conclusions. We found a simple progression model for loaded sit-to-stands (STAND) feasible in acutely admitted older medical patients (≥65 yrs), based on our pre-specified criteria for feasibility....... and dose for older patients. Therefore, our aim was to test the feasibility of a progression model for loaded sit-to-stand training among older hospitalized patients. Methods. This is a prospective cohort study conducted as a feasibility study prior to a full-scale trial. We included twenty-four older...

  10. A non-parametric consistency test of the ΛCDM model with Planck CMB data

    Energy Technology Data Exchange (ETDEWEB)

    Aghamousa, Amir; Shafieloo, Arman [Korea Astronomy and Space Science Institute, Daejeon 305-348 (Korea, Republic of); Hamann, Jan, E-mail: amir@aghamousa.com, E-mail: jan.hamann@unsw.edu.au, E-mail: shafieloo@kasi.re.kr [School of Physics, The University of New South Wales, Sydney NSW 2052 (Australia)

    2017-09-01

    Non-parametric reconstruction methods, such as Gaussian process (GP) regression, provide a model-independent way of estimating an underlying function and its uncertainty from noisy data. We demonstrate how GP-reconstruction can be used as a consistency test between a given data set and a specific model by looking for structures in the residuals of the data with respect to the model's best-fit. Applying this formalism to the Planck temperature and polarisation power spectrum measurements, we test their global consistency with the predictions of the base ΛCDM model. Our results do not show any serious inconsistencies, lending further support to the interpretation of the base ΛCDM model as cosmology's gold standard.

  11. Outcomes Definitions and Statistical Tests in Oncology Studies: A Systematic Review of the Reporting Consistency.

    Science.gov (United States)

    Rivoirard, Romain; Duplay, Vianney; Oriol, Mathieu; Tinquaut, Fabien; Chauvin, Franck; Magne, Nicolas; Bourmaud, Aurelie

    2016-01-01

    Quality of reporting for Randomized Clinical Trials (RCTs) in oncology was analyzed in several systematic reviews, but, in this setting, there is paucity of data for the outcomes definitions and consistency of reporting for statistical tests in RCTs and Observational Studies (OBS). The objective of this review was to describe those two reporting aspects, for OBS and RCTs in oncology. From a list of 19 medical journals, three were retained for analysis, after a random selection: British Medical Journal (BMJ), Annals of Oncology (AoO) and British Journal of Cancer (BJC). All original articles published between March 2009 and March 2014 were screened. Only studies whose main outcome was accompanied by a corresponding statistical test were included in the analysis. Studies based on censored data were excluded. Primary outcome was to assess quality of reporting for description of primary outcome measure in RCTs and of variables of interest in OBS. A logistic regression was performed to identify covariates of studies potentially associated with concordance of tests between Methods and Results parts. 826 studies were included in the review, and 698 were OBS. Variables were described in Methods section for all OBS studies and primary endpoint was clearly detailed in Methods section for 109 RCTs (85.2%). 295 OBS (42.2%) and 43 RCTs (33.6%) had perfect agreement for reported statistical test between Methods and Results parts. In multivariable analysis, variable "number of included patients in study" was associated with test consistency: aOR (adjusted Odds Ratio) for third group compared to first group was equal to: aOR Grp3 = 0.52 [0.31-0.89] (P value = 0.009). Variables in OBS and primary endpoint in RCTs are reported and described with a high frequency. However, statistical tests consistency between methods and Results sections of OBS is not always noted. Therefore, we encourage authors and peer reviewers to verify consistency of statistical tests in oncology studies.

  12. 300 GHz imaging with 8 meter stand-off distance and one-dimensional synthetic image reconstruction

    DEFF Research Database (Denmark)

    Keil, Andreas; Quast, Holger; Loeffler, Torsten

    2011-01-01

    An active system for stand-off imaging operating in a frequency range from 234 GHz to 306 GHz is presented. Imaging is achieved by combining a line array consisting of 8 emitters and 16 detectors with a scanning cylindrical mirror system. A stand-off distance of 7-8 m is achieved using a system o...

  13. Standard test methods for determining chemical durability of nuclear, hazardous, and mixed waste glasses and multiphase glass ceramics: The product consistency test (PCT)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These product consistency test methods A and B evaluate the chemical durability of homogeneous glasses, phase separated glasses, devitrified glasses, glass ceramics, and/or multiphase glass ceramic waste forms hereafter collectively referred to as “glass waste forms” by measuring the concentrations of the chemical species released to a test solution. 1.1.1 Test Method A is a seven-day chemical durability test performed at 90 ± 2°C in a leachant of ASTM-Type I water. The test method is static and conducted in stainless steel vessels. Test Method A can specifically be used to evaluate whether the chemical durability and elemental release characteristics of nuclear, hazardous, and mixed glass waste forms have been consistently controlled during production. This test method is applicable to radioactive and simulated glass waste forms as defined above. 1.1.2 Test Method B is a durability test that allows testing at various test durations, test temperatures, mesh size, mass of sample, leachant volume, a...

  14. Factors associated with not testing for HIV and consistent condom use among men in Soweto, South Africa.

    Directory of Open Access Journals (Sweden)

    Sakhile Mhlongo

    Full Text Available Besides access to medical male circumcision, HIV testing, access to condoms and consistent condom use are additional strategies men can use to prevent HIV acquisition. We examine male behavior toward testing and condom use.To determine factors associated with never testing for HIV and consistent condom use among men who never test in Soweto.A cross-sectional survey in Soweto was conducted in 1539 men aged 18-32 years in 2007. Data were collected on socio-demographic and behavioral characteristics to determine factors associated with not testing and consistent condom use.Over two thirds (71% of men had not had an HIV test and the majority (55%, n = 602 were young (18-23. Of those not testing, condom use was poor (44%, n = 304. Men who were 18-23 years (aOR: 2.261, CI: 1.534-3.331, with primary (aOR: 2.096, CI: 1.058-4.153 or high school (aOR: 1.622, CI: 1.078-2.439 education, had sex in the last 6 months (aOR: 1.703, CI: 1.055-2.751, and had ≥1 sexual partner (aOR: 1.749, CI: 1.196-2.557 were more likely not to test. Of those reporting condom use (n = 1036, 67%, consistent condom use was 43% (n = 451. HIV testing did not correlate with condom use.Low rates of both condom use and HIV testing among men in a high HIV prevalence setting are worrisome and indicate an urgent need to develop innovative behavioral strategies to address this shortfall. Condom use is poor in this population whether tested or not tested for HIV, indicating no association between condom use and HIV testing.

  15. Frequency and determinants of consistent STI/HIV testing among men who have sex with men testing at STI outpatient clinics in the Netherlands: a longitudinal study.

    Science.gov (United States)

    Visser, Maartje; Heijne, Janneke C M; Hogewoning, Arjan A; van Aar, Fleur

    2017-09-01

    Men who have sex with men (MSM) are at highest risk for STIs and HIV infections in the Netherlands. However, official guidelines on STI testing among MSM are lacking. They are advised to test for STIs at least every six months, but their testing behaviour is not well known. This study aimed to get insight into the proportion and determinants of consistent 6-monthly STI testing among MSM testing at STI outpatient clinics in the Netherlands. This study included longitudinal surveillance data of STI consultations among MSM from all 26 STI outpatient clinics in the Netherlands between 1 June 2014 and 31 December 2015. Multinomial logistic regression analysis was used to identify determinants of consistent 6-monthly testing compared with single testing and inconsistent testing. Determinants of time between consultations among men with multiple consultations were analysed using a Cox Prentice-Williams-Peterson gap-time model. A total of 34 605 STI consultations of 18 634 MSM were included. 8966 (48.1%) men had more than one consultation, and 3516 (18.9%) men tested consistently 6-monthly. Indicators of high sexual risk behaviour, including having a history of STI, being HIV positive and having more than 10 sex partners, were positively associated with both being a consistent tester and returning to the STI clinic sooner. Men who were notified by a partner or who reported STI symptoms were also more likely to return to the STI clinic sooner, but were less likely to be consistent testers, identifying a group of event-driven testers. The proportion of consistent 6-monthly testers among MSM visiting Dutch STI outpatient clinics was low. Testing behaviour was associated with sexual risk behaviour, but exact motives to test consistently remain unclear. Evidence-based testing guidelines are needed to achieve optimal reductions in STI transmission in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence

  16. Development of prolonged standing strain index to quantify risk levels of standing jobs.

    Science.gov (United States)

    Halim, Isa; Omar, Abdul Rahman

    2012-01-01

    Many occupations in industry such as metal stamping workers, electronics parts assembly operators, automotive industry welders, and lathe operators require working in a standing posture for a long time. Prolonged standing can contribute to discomfort and muscle fatigue particularly in the back and legs. This study developed the prolonged standing strain index (PSSI) to quantify the risk levels caused by standing jobs, and proposed recommendations to minimize the risk levels. Risk factors associated with standing jobs, such as working posture, muscles activity, standing duration, holding time, whole-body vibration, and indoor air quality, were the basis for developing the PSSI. All risk factors were assigned multipliers, and the PSSI was the product of those multipliers. Recommendations for improvement are based on the PSSI; however, extensive studies are required to validate their effectiveness. multipliers, and the PSSI was the product of those multipliers. Recommendations for improvement are based on the PSSI; however, extensive studies are required to validate their effectiveness.

  17. Stand-alone containment analysis of Phébus FPT tests with ASTEC and MELCOR codes: the FPT-2 test.

    Science.gov (United States)

    Gonfiotti, Bruno; Paci, Sandro

    2018-03-01

    During the last 40 years, many studies have been carried out to investigate the different phenomena occurring during a Severe Accident (SA) in a Nuclear Power Plant (NPP). Such efforts have been supported by the execution of different experimental campaigns, and the integral Phébus FP tests were probably some of the most important experiments in this field. In these tests, the degradation of a Pressurized Water Reactor (PWR) fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the findings on these and previous tests, numerical codes such as ASTEC and MELCOR have been developed to analyze the evolution of a SA in real NPPs. After the termination of the Phébus FP campaign, these two codes have been furthermore improved to implement the more recent findings coming from different experimental campaigns. Therefore, continuous verification and validation is still necessary to check that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The aim of the present work is to re-analyze the Phébus FPT-2 test employing the updated ASTEC and MELCOR code versions. The analysis focuses on the stand-alone containment aspects of this test, and three different spatial nodalizations of the containment vessel (CV) have been developed. The paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products (FP) behavior. When possible, a comparison among the results obtained during this work and by different authors in previous work is also performed. This paper is part of a series of publications covering the four Phébus FP tests using a PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3, excluding the FPT-4 one, related to the study of the release of low-volatility FP and transuranic elements from a debris bed and a pool of melted fuel.

  18. Stand-alone containment analysis of Phébus FPT tests with ASTEC and MELCOR codes: the FPT-2 test

    Directory of Open Access Journals (Sweden)

    Bruno Gonfiotti

    2018-03-01

    Full Text Available During the last 40 years, many studies have been carried out to investigate the different phenomena occurring during a Severe Accident (SA in a Nuclear Power Plant (NPP. Such efforts have been supported by the execution of different experimental campaigns, and the integral Phébus FP tests were probably some of the most important experiments in this field. In these tests, the degradation of a Pressurized Water Reactor (PWR fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the findings on these and previous tests, numerical codes such as ASTEC and MELCOR have been developed to analyze the evolution of a SA in real NPPs. After the termination of the Phébus FP campaign, these two codes have been furthermore improved to implement the more recent findings coming from different experimental campaigns. Therefore, continuous verification and validation is still necessary to check that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The aim of the present work is to re-analyze the Phébus FPT-2 test employing the updated ASTEC and MELCOR code versions. The analysis focuses on the stand-alone containment aspects of this test, and three different spatial nodalizations of the containment vessel (CV have been developed. The paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products (FP behavior. When possible, a comparison among the results obtained during this work and by different authors in previous work is also performed. This paper is part of a series of publications covering the four Phébus FP tests using a PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3, excluding the FPT-4 one, related to the study of the release of low-volatility FP and transuranic elements from a debris bed and a pool of melted fuel. Keywords: Safety

  19. Cryogenic infrastructure for Fermilab's ILC vertical cavity test facility

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Ginsburg, C.; Huang, Y.; Norris, B.; Ozelis, J.; Peterson, T.; Poloubotko, V.; Rabehl, R.; Sylvester, C.; Wong, M.; /Fermilab

    2006-06-01

    Fermilab is building a Vertical Cavity Test Facility (VCTF) to provide for R&D and pre-production testing of bare 9-cell, 1.3-GHz superconducting RF (SRF) cavities for the International Linear Collider (ILC) program. This facility is located in the existing Industrial Building 1 (IB1) where the Magnet Test Facility (MTF) also resides. Helium and nitrogen cryogenics are shared between the VCTF and MTF including the existing 1500-W at 4.5-K helium refrigerator with vacuum pumping for super-fluid operation (125-W capacity at 2-K). The VCTF is being constructed in multiple phases. The first phase is scheduled for completion in mid 2007, and includes modifications to the IB1 cryogenic infrastructure to allow helium cooling to be directed to either the VCTF or MTF as scheduling demands require. At this stage, the VCTF consists of one Vertical Test Stand (VTS) cryostat for the testing of one cavity in a 2-K helium bath. Planning is underway to provide a total of three Vertical Test Stands at VCTF, each capable of accommodating two cavities. Cryogenic infrastructure improvements necessary to support these additional VCTF test stands include a dedicated ambient temperature vacuum pump, a new helium purification skid, and the addition of helium gas storage. This paper describes the system design and initial cryogenic operation results for the first VCTF phase, and outlines future cryogenic infrastructure upgrade plans for expanding to three Vertical Test Stands.

  20. Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

    International Nuclear Information System (INIS)

    2011-01-01

    The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.

  1. SSC Test Operations Contract Overview

    Science.gov (United States)

    Kleim, Kerry D.

    2010-01-01

    This slide presentation reviews the Test Operations Contract at the Stennis Space Center (SSC). There are views of the test stands layouts, and closer views of the test stands. There are descriptions of the test stand capabilities, some of the other test complexes, the Cryogenic propellant storage facility, the High Pressure Industrial Water (HPIW) facility, and Fluid Component Processing Facility (FCPF).

  2. Testing two novel stump-lifting heads in a final felling Norway spruce stand

    Energy Technology Data Exchange (ETDEWEB)

    Kaerhae, K. (Metsaeteho Oy, Helsinki (Finland)), Email: kalle.karha@metsateho.fi; Mutikainen, A. (TTS Research, Rajamaeki (Finland)), Email: arto.mutikainen@tts.fi

    2009-07-01

    The use of stump and root wood chips has increased very rapidly in the 21st century in Finland: in the year 2000, the total consumption of stump wood chips for energy generation was 10 GWh, while in 2008 it was around 1.2 TWh. Metsaeteho Oy and TTS Research tested two new stump-lifting devices for lifting stumps in a final felling Norway spruce (picea abies) stand. In the time study with the Vaekevae Stump Processor lifting head, the productivity of stump lifting was 7,5 m3 / E{sub 0}-hour when lifting spruce stumps with a diameter of 30 cm from clayey soil, and 8.3 m3 /E{sub 0}-hour when lifting spruce stumps from sandy soil. When lifting stumps with a diameter of 40 cm, the stump-lifting productivity was 9.0 m3 /E{sub 0}-h (clay) and 10,5 m3 / E{sub 0}-h (sand). The results of this relatively restricted test indicated that the Vaekevae Stump Processor is s reliable and effective stump-lifting head that enables the harvesting of high-quality stump raw material for energy generation. The stump lifting productivity of the other lifting head (Jaervinen) was lower than that of the Vaekevae Strump Processor. Some development suggestions for the Jaervinen lifting head were presented and discussed. (orig.)

  3. PID Controller Design for FES Applied to Ankle Muscles in Neuroprosthesis for Standing Balance.

    Science.gov (United States)

    Rouhani, Hossein; Same, Michael; Masani, Kei; Li, Ya Qi; Popovic, Milos R

    2017-01-01

    Closed-loop controlled functional electrical stimulation (FES) applied to the lower limb muscles can be used as a neuroprosthesis for standing balance in neurologically impaired individuals. The objective of this study was to propose a methodology for designing a proportional-integral-derivative (PID) controller for FES applied to the ankle muscles toward maintaining standing balance for several minutes and in the presence of perturbations. First, a model of the physiological control strategy for standing balance was developed. Second, the parameters of a PID controller that mimicked the physiological balance control strategy were determined to stabilize the human body when modeled as an inverted pendulum. Third, this PID controller was implemented using a custom-made Inverted Pendulum Standing Apparatus that eliminated the effect of visual and vestibular sensory information on voluntary balance control. Using this setup, the individual-specific FES controllers were tested in able-bodied individuals and compared with disrupted voluntary control conditions in four experimental paradigms: (i) quiet-standing; (ii) sudden change of targeted pendulum angle (step response); (iii) balance perturbations that simulate arm movements; and (iv) sudden change of targeted angle of a pendulum with individual-specific body-weight (step response). In paradigms (i) to (iii), a standard 39.5-kg pendulum was used, and 12 subjects were involved. In paradigm (iv) 9 subjects were involved. Across the different experimental paradigms and subjects, the FES-controlled and disrupted voluntarily-controlled pendulum angle showed root mean square errors of controlled balance were significantly smaller or tended to be smaller than those observed with voluntarily-controlled balance, implying improved steady-state and transient responses of FES-controlled balance. At the same time, the FES-controlled balance required similar torque levels (no significant difference) as voluntarily

  4. Stand-alone wind system with Vanadium Redox Battery energy storage

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Barote, L.; Weissbach, R.

    2008-01-01

    Energy storage devices are required for power balance and power quality in stand alone wind energy systems. A Vanadium Redox Flow Battery (VRB) system has many features which make its integration with a stand-alone wind energy system attractive. This paper proposes the integration of a VRB system...... with a typical stand-alone wind energy system during wind speed variation as well as transient performance under variable load. The investigated system consists of a variable speed wind turbine with permanent magnet synchronous generator (PMSG), diode rectifier bridge, buck-boost converter, bidirectional charge...... controller, transformer, inverter, ac loads and VRB (to store a surplus of wind energy and to supply power during a wind power shortage). The main purpose is to supply domestic appliances through a single phase 230V, 50Hz inverter. Simulations are accomplished in order to validate the stability of the supply....

  5. The one-leg standing radiograph

    OpenAIRE

    Pinsornsak, P.; Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis wa...

  6. Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance.

    Science.gov (United States)

    Clark, Ross A; Bryant, Adam L; Pua, Yonghao; McCrory, Paul; Bennell, Kim; Hunt, Michael

    2010-03-01

    Impaired standing balance has a detrimental effect on a person's functional ability and increases their risk of falling. There is currently no validated system which can precisely quantify center of pressure (COP), an important component of standing balance, while being inexpensive, portable and widely available. The Wii Balance Board (WBB) fits these criteria, and we examined its validity in comparison with the 'gold standard'-a laboratory-grade force platform (FP). Thirty subjects without lower limb pathology performed a combination of single and double leg standing balance tests with eyes open or closed on two separate occasions. Data from the WBB were acquired using a laptop computer. The test-retest reliability for COP path length for each of the testing devices, including a comparison of the WBB and FP data, was examined using intraclass correlation coefficients (ICC), Bland-Altman plots (BAP) and minimum detectable change (MDC). Both devices exhibited good to excellent COP path length test-retest reliability within-device (ICC=0.66-0.94) and between-device (ICC=0.77-0.89) on all testing protocols. Examination of the BAP revealed no relationship between the difference and the mean in any test, however the MDC values for the WBB did exceed those of the FP in three of the four tests. These findings suggest that the WBB is a valid tool for assessing standing balance. Given that the WBB is portable, widely available and a fraction of the cost of a FP, it could provide the average clinician with a standing balance assessment tool suitable for the clinical setting. Copyright 2009 Elsevier B.V. All rights reserved.

  7. Free-standing nanocomposites with high conductivity and extensibility

    International Nuclear Information System (INIS)

    Chun, Kyoung-Yong; Kim, Shi Hyeong; Shin, Min Kyoon; Kim, Seon Jeong; Kim, Youn Tae; Spinks, Geoffrey M; Aliev, Ali E; Baughman, Ray H

    2013-01-01

    The prospect of electronic circuits that are stretchable and bendable promises tantalizing applications such as skin-like electronics, roll-up displays, conformable sensors and actuators, and lightweight solar cells. The preparation of highly conductive and highly extensible materials remains a challenge for mass production applications, such as free-standing films or printable composite inks. Here we present a nanocomposite material consisting of carbon nanotubes, ionic liquid, silver nanoparticles, and polystyrene–polyisoprene–polystyrene having a high electrical conductivity of 3700 S cm −1 that can be stretched to 288% without permanent damage. The material is prepared as a concentrated dispersion suitable for simple processing into free-standing films. For the unstrained state, the measured thermal conductivity for the electronically conducting elastomeric nanoparticle film is relatively high and shows a non-metallic temperature dependence consistent with phonon transport, while the temperature dependence of electrical resistivity is metallic. We connect an electric fan to a DC power supply using the films to demonstrate their utility as an elastomeric electronic interconnect. The huge strain sensitivity and the very low temperature coefficient of resistivity suggest their applicability as strain sensors, including those that operate directly to control motors and other devices. (paper)

  8. Design and commissioning of Fermilab's vertical test stand for ILC SRF cavities

    International Nuclear Information System (INIS)

    Ozelis, Joseph P.; Carcagno, Ruben; Ginsburg, Camille M.; Huang, Yuenian; Norris, Barry; Peterson, Thomas; Poloubotko, Valeri; Rabehl, roger; Rakhno, Igor; Reid, Clark; Sergatskov, Dmitri A.

    2007-01-01

    As part of its ILC program, Fermilab is developing a facility for vertical testing of SRF cavities. It operates at a nominal temperature of 2K, using a cryoplant that can supply LHe in excess of 20g/sec and provide bath pumping capacity of 125W at 2K. The below-grade cryostat consists of a vacuum vessel and LHe vessel, equipped with magnetic shielding to reduce the ambient magnetic field to <10mG. Internal fixed and external movable radiation shielding ensures that exposure to personnel is minimized. The facility features an integrated personnel safety system consisting of RF switches, interlocks, and area radiation monitors

  9. Thinning results from a mixed upland hardwood stand after 35 years

    Science.gov (United States)

    Ronald J., Jr. Myers; Kenneth R. Roeder; W. Henry McNab

    2008-01-01

    A long-term study of precommercial thinning was installed in a 6-year-old oak-dominated stand regenerated by clearcutting in the southern Appalachian Mountains of North Carolina. Three levels of residual stand density were tested: control (no thinning), and 200, and 400 residual trees per acre (TPA). Objectives of the study were to determine the response of an upland...

  10. Design and development of RF system for vertical test stand for characterization of superconducting RF cavities

    International Nuclear Information System (INIS)

    Mohania, Praveen; Rajput, Vikas; Baxy, Deodatta; Agrawal, Ankur; Mahawar, Ashish; Adarsh, Kunver; Singh, Pratap; Shrivastava, Purushottam

    2011-01-01

    RRCAT is developing a Vertical Test Stand (VTS) to test and qualify 1.3 GHz/650 MHz, SCRF Cavities in collaboration with Fermi National Accelerator Laboratory (FNAL) under Indian Institutions' Fermilab Collaboration. The technical details for VTS is being provided by FNAL, USA. The RF System of VTS needs to provide stable RF power to SCRF cavity with control of amplitude, relative phase and frequency. The incident, reflected, transmitted power and field decay time constant of the cavity are measured to evaluate cavity performance parameters (E, Qo). RF Power is supplied via 500 W Solid State amplifier, 1270-1310 MHz being developed by PHPMS, RRCAT. VTS system is controlled by PXI Platform and National Instruments LabVIEW software. Low Level RF (LLRF) system is used to track the cavity frequency using Phase Locked Loop (PLL). The system is comprised of several integrated functional modules which would be assembled, optimized, and tested separately. Required components and instruments have been identified and procurement for the same is underway. Inhouse development for the Solid State RF amplifier and instrument interfacing is in progress. This paper describes the progress on the development of the RF system for VTS. (author)

  11. Reineke’s stand density index: a quantitative and non-unitless measure of stand density

    Science.gov (United States)

    Curtis L. VanderSchaaf

    2013-01-01

    When used as a measure of relative density, Reineke’s stand density index (SDI) can be made unitless by relating the current SDI to a standard density but when used as a quantitative measure of stand density SDI is not unitless. Reineke’s SDI relates the current stand density to an equivalent number of trees per unit area in a stand with a quadratic mean diameter (Dq)...

  12. The value of imaging in standing position in preoperative breast lymphoscintigraphy.

    Science.gov (United States)

    Anagnostou, Christos; Baiocco, Cinzia; Arnulfo, Alberto; Liberatore, Mauro; Baccheschi, Anna Maria; Inglese, Eugenio

    2011-08-01

    Breast lymphoscintigraphy is an accurate technique, but in a minority of cases the sentinel node (SN) visualization cannot be achieved or can be very difficult. We evaluated the potential clinical advantages and limitations of performing imaging in the standing position. The aim was to establish if this examination modality is quicker and helpful in the presence of "hidden" SN, checking also for any influence of SN skin landmarking in the upright position on the correct intraoperative SN identification. The overall objective was to verify if the standing position can be routinely used in breast lymphoscintigraphy. A total of 144 patients underwent lymphoscintigraphy in both standing and supine positions. In both modalities, a skin landmark was set coincident with the SN orthogonal projections. The acquisition times of 2 groups (each consisting of 45 patients) examined with the standing or supine acquisition modality, were compared. In 6 cases with hidden SN and in 34 cases with difficult or partial visualization in one of the supine views, the standing protocol was effective and led to better and quicker visualization of lymph nodes (median examination time: 25.5 minutes standing, 35.5 minutes supine). Significant differences in skin landmark position between the 2 modalities were present only in overweight patients and in large breasts. This, however, did not have a negative impact on successful intraoperative localization of SN with the gamma probe. Standing acquisition resulted to be a faster, easier, and more accurate examination protocol and can be used as the routine method for SN detection in breast lymphoscintigraphy.

  13. Mr Gary Nairn MP, Chair of the Standing Committee on Science and Innovation, Australia

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Photos 01,04,06,07: Mr Gary Nairn MP, Chair of the Standing Committee on Science and Innovation, Australia,visiting the silicon test laboratory, April 2003. Photos 02,03: From left to right: Mr Gary Nairn MP, Chair of the Standing Committee on Science and Innovation, Australia,visiting the silicon test laboratory with Prof. Steinar Stapnes, Physicist in the ATLAS experiment, April 2003. Photos 02,09: Mrs Kerrye Nairn, Australia,visiting the silicon test laboratory, April 2003

  14. Dynamic QT Interval Changes from Supine to Standing in Healthy Children.

    Science.gov (United States)

    Dionne, Audrey; Fournier, Anne; Dahdah, Nagib; Abrams, Dominic; Khairy, Paul; Abadir, Sylvia

    2018-01-01

    QT-interval variations in response to exercise-induced increases in heart rate have been reported in children and adults in the diagnosis of long QT syndrome (LQTS). A quick standing challenge has been proposed as an alternative provocative test in adults, with no pediatric data yet available. A standing test was performed in 100 healthy children (mean age, 9.7 ± 3.1 years) after 10 minutes in a supine position with continuous electrocardiographic recording. QT intervals were measured at baseline, at maximal heart rate, at maximal QT, and at each minute of a 5-minute recovery while standing. Measurements were taken in leads II/V 5 and were corrected for heart rate (QTc). On standing, the heart rate increased by 29 ± 10 beats per minute (bpm). The QT interval was similar at baseline and on standing (394 ± 34 ms vs 394 ± 34 ms; P = 1.0). However, QTc increased from 426 ± 21 to 509 ± 41 ms (P < 0.001). The 95th percentile for QTc at baseline and maximal heart rate was 457 ms and 563 ms, respectively. At 1 minute of recovery, the QT interval was shorter (375 ± 31 ms) compared with baseline (394 ± 34 ms; P < 0.001) and standing (394 ± 34 ms; P < 0.001). QTc reached baseline values after 1 minute of recovery and remained stable thereafter (423 ± 23 ms at 1 minute; 426 ± 22 ms at 5 minutes; P = 1.0). This first characterization of QTc changes on standing in children shows substantial alterations, which are greater than those seen in adults. Two-thirds of the children would have been misclassified as having LQTS by adult criteria, indicating the need to create child-specific standards. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  15. Sway‐dependent changes in standing ankle stiffness caused by muscle thixotropy

    Science.gov (United States)

    Sakanaka, Tania E.; Lakie, Martin

    2016-01-01

    Key points The passive stiffness of the calf muscles contributes to standing balance, although the properties of muscle tissue are highly labile.We investigated the effect of sway history upon intrinsic ankle stiffness and demonstrated reductions in stiffness of up to 43% during conditions of increased baseline sway.This sway dependence was most apparent when using low amplitude stiffness‐measuring perturbations, and the short‐range stiffness component was smaller during periods of high sway.These characteristics are consistent with the thixotropic properties of the calf muscles causing the observed changes in ankle stiffness.Periods of increased sway impair the passive stabilization of standing, demanding more active neural control of balance. Abstract Quiet standing is achieved through a combination of active and passive mechanisms, consisting of neural control and intrinsic mechanical stiffness of the ankle joint, respectively. The mechanical stiffness is partly determined by the calf muscles. However, the viscoelastic properties of muscle are highly labile, exhibiting a strong dependence on movement history. By measuring the effect of sway history upon ankle stiffness, the present study determines whether this lability has consequences for the passive stabilization of human standing. Ten subjects stood quietly on a rotating platform whose axis was collinear with the ankle joint. Ankle sway was increased by slowly tilting this platform in a random fashion, or decreased by fixing the body to a board. Ankle stiffness was measured by using the same platform to simultaneously apply small, brief perturbations (ankle stiffness by up to 43% compared to the body‐fixed condition. Normal quiet stance was associated with intermediate values. The effect was most apparent when using smaller perturbation amplitudes to measure stiffness (0.1 vs. 0.6 deg). Furthermore, torque responses exhibited a biphasic pattern, consisting of an initial steep rise followed by a

  16. DESIGN OF A SUPERBIKE PADDOCK STAND USING CAD AND CAE TOOLS

    Directory of Open Access Journals (Sweden)

    M.H. Mohd Noh

    2012-06-01

    Full Text Available Two people are required to operate current superbike paddock stands in order to elevate the superbike. Lifting the superbike alone using the current design of paddock stand may be impractical and inconvenient for users. To overcome this limitation, a new design of a superbike paddock stand was conceived that could be operated by a single user. CAD and CAE tools using CATIA V5R18 software were utilised in designing this new stand. A 3D CAD model was developed and analysed through finite element analysis (FEA and a prototype fabricated for verification testing of the design. The use of CAD and CAE tools saved much time in the design work and gave the researchers and designers freedom in producing their own design. However, the most important aspect of this design study was to design a superbike paddock stand that is more practical and convenient for operation by a single user.

  17. Acute effects of rearfoot manipulation on dynamic standing balance in healthy individuals.

    Science.gov (United States)

    Wassinger, Craig A; Rockett, Ariel; Pitman, Lucas; Murphy, Matthew Matt; Peters, Charles

    2014-06-01

    Dynamic standing balance is essential to perform functional activities and is included in the treatment of many lower extremity injuries. Physiotherapists utilize many methods to restore standing balance including stability exercises, functional retraining, and manual therapy. The purpose of this study was to investigate the effects of a rearfoot distraction manipulation on dynamic standing balance. Twenty healthy participants (age: 24.4 ± 2.8 years; height: 162.9 ± 37.7 cm; mass: 68.0 ± 4.8 kg; right leg dominant = 20) completed this study. Following familiarization, dynamic standing balance was assessed during: (1) an experimental condition immediately following a rearfoot distraction manipulation, and (2) a control condition. Dominant leg balance was quantified using the Y-balance test which measures lower extremity reach distances. Reach distances were normalized to leg length and measured in the anterior, posteromedial and posterolateral directions. Overall balance was calculated through the summing of all normalized directions. Paired t-tests and Wilcoxon rank tests were used to compare balance scores for parametric and non-parametric data as appropriate. Significance was set at 0.05 a priori. Effect size (ES) was calculated to determine the clinical impact of the manipulation. Increased reach distances (indicating improved balance) were noted following manipulation for overall balance (p = 0.03, ES = 0.26) and in the posteromedial direction (p = 0.01, ES = 0.42). Reach distances did not differ for the anterior (p = 0.11, ES = 0.16) or posterolateral (p = 0.11, ES = 0.25) components. Dynamic standing balance improved after a rearfoot distraction manipulation in healthy participants. It is hypothesized that manual therapy applied to the foot and ankle may be beneficial to augment other therapeutic modalities when working with patients to improve dynamic standing balance. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Temporal changes in vegetation of a virgin beech woodland remnant: stand-scale stability with intensive fine-scale dynamics governed by stand dynamic events

    Directory of Open Access Journals (Sweden)

    Tibor Standovár

    2017-03-01

    Full Text Available The aim of this resurvey study is to check if herbaceous vegetation on the forest floor exhibits overall stability at the stand-scale in spite of intensive dynamics at the scale of individual plots and stand dynamic events (driven by natural fine scale canopy gap dynamics. In 1996, we sampled a 1.5 ha patch using 0.25 m² plots placed along a 5 m × 5 m grid in the best remnant of central European montane beech woods in Hungary. All species in the herbaceous layer and their cover estimates were recorded. Five patches representing different stand developmental situations (SDS were selected for resurvey. In 2013, 306 plots were resurveyed by using blocks of four 0.25 m² plots to test the effects of imperfect relocation. We found very intensive fine-scale dynamics in the herbaceous layer with high species turnover and sharp changes in ground layer cover at the local-scale (< 1 m2. A decrease in species richness and herbaceous layer cover, as well as high species turnover, characterized the closing gaps. Colonization events and increasing species richness and herbaceous layer cover prevailed in the two newly created gaps. A pronounced decrease in the total cover, but low species turnover and survival of the majority of the closed forest specialists was detected by the resurvey at the stand-scale. The test aiming at assessing the effect of relocation showed a higher time effect than the effect of imprecise relocation. The very intensive fine-scale dynamics of the studied beech forest are profoundly determined by natural stand dynamics. Extinction and colonisation episodes even out at the stand-scale, implying an overall compositional stability of the herbaceous vegetation at the given spatial and temporal scale. We argue that fine-scale gap dynamics, driven by natural processes or applied as a management method, can warrant the survival of many closed forest specialist species in the long-run. Nomenclature: Flora Europaea (Tutin et al. 2010 for

  19. Development of a Physical Employment Testing Battery for Armor Soldiers: 19D Cavalry Scout and 19K M1 Armor Crewman

    Science.gov (United States)

    2015-12-01

    around the course in the direction indicated, without knocking the cones. Time to complete the course was recorded (14). Standing Long Jump...easily purchased at a sporting goods store (as requested by Mr. Brinkley, G3/5/7 TRADOC). This model excluded the arm ergometer, handgrip, upright...purchased at a sporting goods store (R2 = 0.84). This model resulted in a test battery consisting of four tests: squat lift, standing long jump, beep

  20. Restless behavior increases over time, but not with compressibility of the flooring surface, during forced standing at the feed bunk.

    Science.gov (United States)

    Krebs, N; Berry, S L; Tucker, C B

    2011-01-01

    Interest in the use of rubber flooring in freestall barns has increased, but little is known about which design features of these surfaces are important for cattle. In 2 experiments, we evaluated how the type and compressibility of the flooring surface in front of the feed bunk influenced the behavioral response to 4 h of forced standing after morning milking. Two flooring types were compared: rubber and concrete. Rubber was tested at 3 levels of compressibility: 2, 4, and 35 times as compressible as concrete. Four hours of forced standing was evaluated because it mimicked conditions that can occur on dairies, particularly when waiting for artificial insemination or veterinary treatment. The effects of cow weight and hoof surface area, gait score, and hoof health on the response to treatment were evaluated. Restless behavior, as measured by number of steps, almost doubled over the 4h of forced standing, regardless of flooring material. Cows lay down, on average, within 5 min after access to the lying area was provided. These results indicate that the 4 h of forced standing was uncomfortable. No differences in restless behavior were observed in association with the type or compressibility of the flooring surface in front of the feed bunk. Cow size, hoof health, or gait score did not consistently explain the response to the flooring treatments or stepping rate, although these populations of animals were generally healthy. It is unclear if comfort did not differ between the flooring options tested during 4 h of forced standing or if alterative methodology, such as measuring more subtle shifts in weight, is required to assess design features of rubber flooring. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. Nuclear waste glass product consistency test (PCT): Version 7.0. Revision 3

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-06-01

    Liquid high-level nuclear waste will be immobilized at the Savannah River Site (SRS) by vitrification in borosilicate glass. The glass will be produced in the Defense Waste Processing Facility (DWPF), poured into stainless steel canisters, and eventually disposed of in a geologic repository. In order to comply with the Waste Acceptance Product Specifications (WAPS), the durability of the glass needs to be measured during production to assure its long term stability and radionuclide release properties. A durability test, designated the Product Consistency Test (PCT), was developed for DWPF glass in order to meet the WAPS requirements. The response of the PCT procedure was based on extensive testing with glasses of widely different compositions. The PCT was determined to be very reproducible, to yield reliable results rapidly, and to be easily performed in shielded cell facilities with radioactive samples. Version 7.0 of the PCT procedure is attached. This draft version has been submitted to ASTM for full committee (C26, Nuclear Fuel Cycle) ballot after being balloted successfully through subcommittee C26.13 on Repository Waste Package Materials Testing

  2. Strategies for equilibrium maintenance during single leg standing on a wobble board

    DEFF Research Database (Denmark)

    Silva, Priscila de Brito; Oliveira, Anderson Souza; Mrachacz-Kersting, Natalie

    2016-01-01

    The aim of this study was to identify and compare movement strategies used to maintain balance while single leg standing on either a firm surface (FS) or on a wobble board (WB). In 17 healthy men, retroreflective markers were positioned on the xiphoid process and nondominant lateral malleolus...... requires movement beyond the ankle strategy as described for the FS task. WB standing likely demands different biomechanical and neuromuscular control strategies, which has immediate implications for the significance of WB tests in contrast to FS balance tests. Differences in control strategies will also...

  3. Effects of bilateral swing-away grab bars on the biomechanics of stand-to-sit and sit-to-stand toilet transfers.

    Science.gov (United States)

    Lee, Su Jin; Mehta-Desai, Ricky; Oh, Kyunggeune; Sanford, Jon; Prilutsky, Boris I

    2018-03-09

    Kinetic characteristics of transfers to and from a toilet performed using bilateral grab bars are not fully quantified to inform grab bar design and configuration. The purpose of this study was to (1) determine effects of bilateral swing-away grab bars on peaks of ankle, knee and hip joint moments during grab bar assisted stand-to-sit and sit-to-stand transfers; and (2) determine effects of three different heights and widths of swing-away grab bars on the same kinetic characteristics. Healthy subjects (N = 11, age 25-58 years) performed stand-to-sit and sit-to-stand transfers with and without grab bars. In transfers with grab bars, 9 grab bar configurations were tested by varying their height from the floor (0.787 m, 0.813 m, 0.838 m; 31″-33″) and width, the distance of each grab bar from the toilet's centerline (0.330 m, 0.356 m, 0.381 m; 13″-15″). Motion capture, force plate and inverse dynamics analysis were used to determine lower limb joint moments. The use of bilateral grab bars generally reduced the peak magnitude of extension moments at lower limb joints during stand-to-sit and sit-to-stand transfers (p away grab bars is useful for informing grab bar design and configuration recommendations for assisted living and skilled nursing facilities. Our findings suggest that the swing-away grab bars located at certain ranges are a reasonable alternative to the grab bars mandated by the current Americans with Disabilities Act (ADA) Accessibility Guidelines. Future research investigating the effects of grab bars on transfer performance should consider additional factors, such as a wider range of abilities and transfer methods of the users.

  4. Stands for testing the strength of welded pipe materials under the action of a corrosive medium

    Directory of Open Access Journals (Sweden)

    M.A. Kolodyi

    2017-12-01

    Full Text Available In order to study the features of the destruction of materials of pipelines for the transportation of oil, gas, products of processing of oil, water and other substances in the laboratory of the department of development of minerals named by prof. Bakka N.T. the complex of installations is invented, for which Ukrainian patents were obtained as utility models No. 30794, No. 52493, for the study of the working capacity of the elements of the listed pipeline systems in conditions that are as close as possible to the operational under the influence of the corrosive medium. Rotary vacuum devices were used as the basic elements of the proposed installations for testing the materials of the welded tubes for durability at single tensile and under flat stress conditions. The article presents the design of research stands for testing the durability of pipe materials and welds of pipelines using samples of materials and natural pipes (shortened under the influence of static, low cyclic and dynamic loads, and analyzes the influence of aggressive media.

  5. Plasma turbulence driven by transversely large-scale standing shear Alfvén waves

    International Nuclear Information System (INIS)

    Singh, Nagendra; Rao, Sathyanarayan

    2012-01-01

    Using two-dimensional particle-in-cell simulations, we study generation of turbulence consisting of transversely small-scale dispersive Alfvén and electrostatic waves when plasma is driven by a large-scale standing shear Alfvén wave (LS-SAW). The standing wave is set up by reflecting a propagating LS-SAW. The ponderomotive force of the standing wave generates transversely large-scale density modifications consisting of density cavities and enhancements. The drifts of the charged particles driven by the ponderomotive force and those directly caused by the fields of the standing LS-SAW generate non-thermal features in the plasma. Parametric instabilities driven by the inherent plasma nonlinearities associated with the LS-SAW in combination with the non-thermal features generate small-scale electromagnetic and electrostatic waves, yielding a broad frequency spectrum ranging from below the source frequency of the LS-SAW to ion cyclotron and lower hybrid frequencies and beyond. The power spectrum of the turbulence has peaks at distinct perpendicular wave numbers (k ⊥ ) lying in the range d e −1 -6d e −1 , d e being the electron inertial length, suggesting non-local parametric decay from small to large k ⊥ . The turbulence spectrum encompassing both electromagnetic and electrostatic fluctuations is also broadband in parallel wave number (k || ). In a standing-wave supported density cavity, the ratio of the perpendicular electric to magnetic field amplitude is R(k ⊥ ) = |E ⊥ (k ⊥ )/|B ⊥ (k ⊥ )| ≪ V A for k ⊥ d e A is the Alfvén velocity. The characteristic features of the broadband plasma turbulence are compared with those available from satellite observations in space plasmas.

  6. Effect of footwear on standing balance in healthy young adult males.

    Science.gov (United States)

    Alghadir, Ahmad H; Zafar, Hamayun; Anwer, Shahnawaz

    2018-03-01

    The present study aimed to evaluate the effect of footwear on standing balance in healthy young adult males. Thirty healthy male participants aged 20-30 years were tested for standing balance on the Balance Master on three occasions, including wearing a sandal, standard shoe, or no footwear (barefoot). The tests of postural stability include; "Modified Clinical Test of Sensory Interaction on Balance" (mCTSIB), "Unilateral Stance" (US), and the "Limits of Stability" (LOS). The balance scores (mCTSIB, US, and LOS) was analyzed. There was a significant effect between footwear conditions for mCTIB with eye closed on a firm surface (p=0.002). There was a significant effect between footwear conditions for the US with eye open and closed (p⟨0.05). There was a significant effect between footwear conditions for LOS reaction time during forward movement (p=0.02). Similarly, there was a significant effect between footwear conditions for LOS reaction time during left side movement (p=0.01). Wearing sandals compared to bare feet significantly increased postural sway and reduced stability in healthy young adult males. However, wearing a standard shoe compared to bare feet did not significantly affect balance scores in standing.

  7. The internal consistency of the standard gamble: tests after adjusting for prospect theory.

    Science.gov (United States)

    Oliver, Adam

    2003-07-01

    This article reports a study that tests whether the internal consistency of the standard gamble can be improved upon by incorporating loss weighting and probability transformation parameters in the standard gamble valuation procedure. Five alternatives to the standard EU formulation are considered: (1) probability transformation within an EU framework; and, within a prospect theory framework, (2) loss weighting and full probability transformation, (3) no loss weighting and full probability transformation, (4) loss weighting and no probability transformation, and (5) loss weighting and partial probability transformation. Of the five alternatives, only the prospect theory formulation with loss weighting and no probability transformation offers an improvement in internal consistency over the standard EU valuation procedure.

  8. How Well Does the Sum Score Summarize the Test? Summability as a Measure of Internal Consistency

    NARCIS (Netherlands)

    Goeman, J.J.; De, Jong N.H.

    2018-01-01

    Many researchers use Cronbach's alpha to demonstrate internal consistency, even though it has been shown numerous times that Cronbach's alpha is not suitable for this. Because the intention of questionnaire and test constructers is to summarize the test by its overall sum score, we advocate

  9. Recruitment of motor units in the medial gastrocnemius muscle during human quiet standing: is recruitment intermittent? What triggers recruitment?

    Science.gov (United States)

    Vieira, Taian M M; Loram, Ian D; Muceli, Silvia; Merletti, Roberto; Farina, Dario

    2012-01-01

    The recruitment and the rate of discharge of motor units are determinants of muscle force. Within a motoneuron pool, recruitment and rate coding of individual motor units might be controlled independently, depending on the circumstances. In this study, we tested whether, during human quiet standing, the force of the medial gastrocnemius (MG) muscle is predominantly controlled by recruitment or rate coding. If MG control during standing was mainly due to recruitment, then we further asked what the trigger mechanism is. Is it determined internally, or is it related to body kinematics? While seven healthy subjects stood quietly, intramuscular electromyograms were recorded from the MG muscle with three pairs of wire electrodes. The number of active motor units and their mean discharge rate were compared for different sway velocities and positions. Motor unit discharges occurred more frequently when the body swayed faster and forward (Pearson R = 0.63; P motor unit potentials was explained chiefly by the recruitment of additional units. During forward body shifts, the median number of units detected increased from 3 to 11 (P motor units did not discharge continuously throughout standing. They were recruited within individual, forward sways and intermittently, with a modal rate of two recruitments per second. This modal rate is consistent with previous circumstantial evidence relating the control of standing to an intrinsic, higher level planning process.

  10. On the Consistency of Bootstrap Testing for a Parameter on the Boundary of the Parameter Space

    DEFF Research Database (Denmark)

    Cavaliere, Giuseppe; Nielsen, Heino Bohn; Rahbek, Anders

    2017-01-01

    It is well known that with a parameter on the boundary of the parameter space, such as in the classic cases of testing for a zero location parameter or no autoregressive conditional heteroskedasticity (ARCH) effects, the classic nonparametric bootstrap – based on unrestricted parameter estimates...... – leads to inconsistent testing. In contrast, we show here that for the two aforementioned cases, a nonparametric bootstrap test based on parameter estimates obtained under the null – referred to as ‘restricted bootstrap’ – is indeed consistent. While the restricted bootstrap is simple to implement...... in practice, novel theoretical arguments are required in order to establish consistency. In particular, since the bootstrap is analysed both under the null hypothesis and under the alternative, non-standard asymptotic expansions are required to deal with parameters on the boundary. Detailed proofs...

  11. PID Controller Design for FES Applied to Ankle Muscles in Neuroprosthesis for Standing Balance

    Directory of Open Access Journals (Sweden)

    Hossein Rouhani

    2017-06-01

    Full Text Available Closed-loop controlled functional electrical stimulation (FES applied to the lower limb muscles can be used as a neuroprosthesis for standing balance in neurologically impaired individuals. The objective of this study was to propose a methodology for designing a proportional-integral-derivative (PID controller for FES applied to the ankle muscles toward maintaining standing balance for several minutes and in the presence of perturbations. First, a model of the physiological control strategy for standing balance was developed. Second, the parameters of a PID controller that mimicked the physiological balance control strategy were determined to stabilize the human body when modeled as an inverted pendulum. Third, this PID controller was implemented using a custom-made Inverted Pendulum Standing Apparatus that eliminated the effect of visual and vestibular sensory information on voluntary balance control. Using this setup, the individual-specific FES controllers were tested in able-bodied individuals and compared with disrupted voluntary control conditions in four experimental paradigms: (i quiet-standing; (ii sudden change of targeted pendulum angle (step response; (iii balance perturbations that simulate arm movements; and (iv sudden change of targeted angle of a pendulum with individual-specific body-weight (step response. In paradigms (i to (iii, a standard 39.5-kg pendulum was used, and 12 subjects were involved. In paradigm (iv 9 subjects were involved. Across the different experimental paradigms and subjects, the FES-controlled and disrupted voluntarily-controlled pendulum angle showed root mean square errors of <1.2 and 2.3 deg, respectively. The root mean square error (all paradigms, rise time, settle time, and overshoot [paradigms (ii and (iv] in FES-controlled balance were significantly smaller or tended to be smaller than those observed with voluntarily-controlled balance, implying improved steady-state and transient responses of FES

  12. Full-scale locomotive dynamic crash testing and correlations : locomotive consist colliding with steel coil truck at grade crossing (test 3).

    Science.gov (United States)

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision between a locomotive and a highway truck loaded with two heavy steel coils. The locomotive consist was moving at 58 miles per hour before it struc...

  13. Evaluation of the entropy consistent euler flux on 1D and 2D test problems

    Science.gov (United States)

    Roslan, Nur Khairunnisa Hanisah; Ismail, Farzad

    2012-06-01

    Perhaps most CFD simulations may yield good predictions of pressure and velocity when compared to experimental data. Unfortunately, these results will most likely not adhere to the second law of thermodynamics hence comprising the authenticity of predicted data. Currently, the test of a good CFD code is to check how much entropy is generated in a smooth flow and hope that the numerical entropy produced is of the correct sign when a shock is encountered. Herein, a shock capturing code written in C++ based on a recent entropy consistent Euler flux is developed to simulate 1D and 2D flows. Unlike other finite volume schemes in commercial CFD code, this entropy consistent flux (EC) function precisely satisfies the discrete second law of thermodynamics. This EC flux has an entropy-conserved part, preserving entropy for smooth flows and a numerical diffusion part that will accurately produce the proper amount of entropy, consistent with the second law. Several numerical simulations of the entropy consistent flux have been tested on two dimensional test cases. The first case is a Mach 3 flow over a forward facing step. The second case is a flow over a NACA 0012 airfoil while the third case is a hypersonic flow passing over a 2D cylinder. Local flow quantities such as velocity and pressure are analyzed and then compared with mainly the Roe flux. The results herein show that the EC flux does not capture the unphysical rarefaction shock unlike the Roe-flux and does not easily succumb to the carbuncle phenomenon. In addition, the EC flux maintains good performance in cases where the Roe flux is known to be superior.

  14. Modelling modulus of elasticity of Pinus pinaster Ait. in northwestern Spain with standing tree acoustic measurements, tree, stand and site variables

    Directory of Open Access Journals (Sweden)

    Esther Merlo

    2014-04-01

    Full Text Available Aim of study: Modelling the structural quality of Pinus pinaster Ait. wood on the basis of measurements made on standing trees is essential because of the importance of the species in the Galician forestry and timber industries and the good mechanical properties of its wood. In this study, we investigated how timber stiffness is affected by tree and stand properties, climatic and edaphic characteristics and competition. Area of study: The study was performed in Galicia, north-western Spain.Material and methods: Ten pure and even-aged P. pinaster stands were selected and tree and stand variables and the stress wave velocity of 410 standing trees were measured. A sub-sample of 73 trees, representing the variability in acoustic velocity, were felled and sawed into structural timber pieces (224 which were subjected to a bending test to determine the modulus of elasticity (MOE. Main results: Linear models including wood properties explained more than 97%, 73% and 60% of the observed MOE variability at site, tree and board level, respectively, with acoustic velocity and wood density as the main regressors. Other linear models, which did not include wood density, explained more than 88%, 69% and 55% of the observed MOE variability at site, tree and board level, respectively, with acoustic velocity as the main regressor. Moreover, a classification tree for estimating the visual grade according to standard UNE 56544:2011 was developed. Research highlights: The results have demonstrated the usefulness of acoustic velocity for predicting MOE in standing trees. The use of the fitted equations together with existing dynamic growth models will enable preliminary assessment of timber stiffness in relation to different silvicultural alternatives used with this species.Keywords: stress wave velocity, modulus of elasticity, site index, competition index, stepwise regression, CART.

  15. Development of an ASTM standard glass durability test, the Product Consistency Test (PCT), for high level radioactive waste glass

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-01-01

    The nation's first, and the world's largest, facility to immobilize high-level nuclear waste in durable borosilicate glass has started operation at the Savannah River Site (SRS) in Aiken, South Carolina. The product specifications on the glass wasteform produced in the Defense Waste Processing Facility (DWPF) required extensive characterization of the glass product before actual production began and for continued characterization during production. To aid in this characterization, a glass durability (leach) test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. Using existing tests as a starting point, the DWPF Product Consistency Test (PCT was developed in which crushed glass samples are exposed to 90 ± 2 degree C deionized water for seven days. Based on extensive testing, including a seven-laboratory round robin and confirmatory testing with radioactive samples, the PCT is very reproducible, yields reliable results rapidly, and can be performed in shielded cell facilities with radioactive samples

  16. Relationship between the Berg Balance Scale and Static Balance Test in Hemiplegic Patients with Stroke

    OpenAIRE

    Suzuki, Makoto; Fujisawa, Hiroyuki; Machida, Yooichiro; Minakata, Shin

    2013-01-01

    [Purpose] The purpose of this study was to analyze the relationship between results of the Berg Balance Scale (BBS) and Static Balance Test (SBT) in hemiplegic patients with stroke. [Subjects] The subjects were 39 hemiplegic patients (25 men, 14 women; mean age, 69.4 ? 11.0?years) with stroke that had occurred within the preceding 6 months and who had good understanding of verbal instructions. [Methods] The SBT consists of five posture-holding tasks (sitting, stride standing, close standing, ...

  17. Laparoscopic cholecystectomy poses physical injury risk to surgeons: analysis of hand technique and standing position.

    Science.gov (United States)

    Youssef, Yassar; Lee, Gyusung; Godinez, Carlos; Sutton, Erica; Klein, Rosemary V; George, Ivan M; Seagull, F Jacob; Park, Adrian

    2011-07-01

    This study compares surgical techniques and surgeon's standing position during laparoscopic cholecystectomy (LC), investigating each with respect to surgeons' learning, performance, and ergonomics. Little homogeneity exists in LC performance and training. Variations in standing position (side-standing technique vs. between-standing technique) and hand technique (one-handed vs. two-handed) exist. Thirty-two LC procedures performed on a virtual reality simulator were video-recorded and analyzed. Each subject performed four different procedures: one-handed/side-standing, one-handed/between-standing, two-handed/side-standing, and two-handed/between-standing. Physical ergonomics were evaluated using Rapid Upper Limb Assessment (RULA). Mental workload assessment was acquired with the National Aeronautics and Space Administration-Task Load Index (NASA-TLX). Virtual reality (VR) simulator-generated performance evaluation and a subjective survey were analyzed. RULA scores were consistently lower (indicating better ergonomics) for the between-standing technique and higher (indicating worse ergonomics) for the side-standing technique, regardless of whether one- or two-handed. Anatomical scores overall showed side-standing to have a detrimental effect on the upper arms and trunk. The NASA-TLX showed significant association between the side-standing position and high physical demand, effort, and frustration (p<0.05). The two-handed technique in the side-standing position required more effort than the one-handed (p<0.05). No difference in operative time or complication rate was demonstrated among the four procedures. The two-handed/between-standing method was chosen as the best procedure to teach and standardize. Laparoscopic cholecystectomy poses a risk of physical injury to the surgeon. As LC is currently commonly performed in the United States, the left side-standing position may lead to increased physical demand and effort, resulting in ergonomically unsound conditions for

  18. Quantification of the sit-to-stand movement for monitoring age-related motor deterioration using the Nintendo Wii Balance Board.

    Directory of Open Access Journals (Sweden)

    Go Yamako

    Full Text Available Simple methods for quantitative evaluations of individual motor performance are crucial for the early detection of motor deterioration. Sit-to-stand movement from a chair is a mechanically demanding component of activities of daily living. Here, we developed a novel method using the ground reaction force and center of pressure measured from the Nintendo Wii Balance Board to quantify sit-to-stand movement (sit-to-stand score and investigated the age-related change in the sit-to-stand score as a method to evaluate reduction in motor performance. The study enrolled 503 participants (mean age ± standard deviation, 51.0 ± 19.7 years; range, 20-88 years; male/female ratio, 226/277 without any known musculoskeletal conditions that limit sit-to-stand movement, which were divided into seven 10-year age groups. The participants were instructed to stand up as quickly as possible, and the sit-to-stand score was calculated as the combination of the speed and balance indices, which have a tradeoff relationship. We also performed the timed up and go test, a well-known clinical test used to evaluate an individual's mobility. There were significant differences in the sit-to-stand score and timed up and go time among age groups. The mean sit-to-stand score for 60s, 70s, and 80s were 77%, 68%, and 53% of that for the 20s, respectively. The timed up and go test confirmed the age-related decrease in mobility of the participants. In addition, the sit-to-stand score measured using the Wii Balance Board was compared with that from a laboratory-graded force plate using the Bland-Altman plot (bias = -3.1 [ms]-1, 95% limit of agreement: -11.0 to 3.9 [ms]-1. The sit-to-stand score has good inter-device reliability (intraclass correlation coefficient = 0.87. Furthermore, the test-retest reliability is substantial (intraclass correlation coefficient = 0.64. Thus, the proposed STS score will be useful to detect the early deterioration of motor performance.

  19. Quantification of the sit-to-stand movement for monitoring age-related motor deterioration using the Nintendo Wii Balance Board.

    Science.gov (United States)

    Yamako, Go; Chosa, Etsuo; Totoribe, Koji; Fukao, Yuu; Deng, Gang

    2017-01-01

    Simple methods for quantitative evaluations of individual motor performance are crucial for the early detection of motor deterioration. Sit-to-stand movement from a chair is a mechanically demanding component of activities of daily living. Here, we developed a novel method using the ground reaction force and center of pressure measured from the Nintendo Wii Balance Board to quantify sit-to-stand movement (sit-to-stand score) and investigated the age-related change in the sit-to-stand score as a method to evaluate reduction in motor performance. The study enrolled 503 participants (mean age ± standard deviation, 51.0 ± 19.7 years; range, 20-88 years; male/female ratio, 226/277) without any known musculoskeletal conditions that limit sit-to-stand movement, which were divided into seven 10-year age groups. The participants were instructed to stand up as quickly as possible, and the sit-to-stand score was calculated as the combination of the speed and balance indices, which have a tradeoff relationship. We also performed the timed up and go test, a well-known clinical test used to evaluate an individual's mobility. There were significant differences in the sit-to-stand score and timed up and go time among age groups. The mean sit-to-stand score for 60s, 70s, and 80s were 77%, 68%, and 53% of that for the 20s, respectively. The timed up and go test confirmed the age-related decrease in mobility of the participants. In addition, the sit-to-stand score measured using the Wii Balance Board was compared with that from a laboratory-graded force plate using the Bland-Altman plot (bias = -3.1 [ms]-1, 95% limit of agreement: -11.0 to 3.9 [ms]-1). The sit-to-stand score has good inter-device reliability (intraclass correlation coefficient = 0.87). Furthermore, the test-retest reliability is substantial (intraclass correlation coefficient = 0.64). Thus, the proposed STS score will be useful to detect the early deterioration of motor performance.

  20. [Soil quality assessment of forest stand in different plantation esosystems].

    Science.gov (United States)

    Huang, Yu; Wang, Silong; Feng, Zongwei; Gao, Hong; Wang, Qingkui; Hu, Yalin; Yan, Shaokui

    2004-12-01

    After a clear-cutting of the first generation Cunninghamia lanceolata plantation in 1982, three plantation ecosystems, pure Michelia macclurei stand (PMS), pure Chinese-fir stand (PCS) and their mixed stand, were established in spring 1983, and their effects on soil characteristics were evaluated by measuring some soil physical, chemical, microbiological and biochemical parameters. After 20 years' plantation, all test indices showed differences among different forest management models. Both PMS and MCM had a favorable effect on soil fertility maintenance. Soil quality assessment showed that some soil functions, e.g., water availability, nutrient availability, root suitability and soil quality index were all in a moderate level under the mixed and pure PMS stands, whereas in a relatively lower level under successive PCS stand. The results also showed that there existed close correlations between soil total organic C (TOC), cation exchange capacity (CEC), microbial biomass-C (Cmic) and other soil physical, chemical and biological indices. Therefore, TOC, CEC and Cmic could be used as the indicators in assessing soil quality in this study area. In addition, there were also positive correlations between soil microbial biomass-C and TOC, soil microbial biomass-N and total N, and soil microbial biomass-P and total P in the present study.

  1. THE 30-S CHAIR STAND TEST AND HABITUAL MOBILITY PREDICT REHABILITATION NEEDS AFTER ACUTE ADMISSION

    DEFF Research Database (Denmark)

    Hansen Bruun, Inge; Nørgaard, Birgitte; Backer Mogensen, Christian

    2016-01-01

    that no approval is needed. Purpose The study aimed to evaluate if the 30 Second Chair Stand test (30s-CST) combined with other variables was able to predict rehabilitation needs among acutely admitted elderly patient. Low physical ability were defined as a 30s-CST–score ≤ 8 one month after admission......Relevance: Responding to Changing Population Needs. The elderly population is growing and represents an increasing proportion of elderly admitted to a short stay unit in an emergency department (ED). One month after admission a fifth of the elderly patients have low physical ability and therefore...... were included if oriented in time and place, able to sit on a chair and have a 30s-CST–score ≤ 8. Baseline data were collected within the first 48 hours of admission and the 30s-CST again one month after admission. All risk factors are identified in the literature. The 30s-CST is used at community...

  2. Thinning in artificially regenerated young beech stands

    Directory of Open Access Journals (Sweden)

    Novák Jiří

    2015-12-01

    Full Text Available Although beech stands are usually regenerated naturally, an area of up to 5,000 ha year−1 is artificially regenerated by beech in the Czech Republic annually. Unfortunately, these stands often showed insufficient stand density and, consequently, lower quality of stems. Therefore, thinning methods developed for naturally regenerated beech stands are applicable with difficulties. The paper evaluates the data from two thinning experiments established in young artificially regenerated beech stands located in different growing conditions. In both experiments, thinning resulted in the lower amount of salvage cut in following years. Positive effect of thinning on periodic stand basal area increment and on periodic diameter increment of dominant trees was found in the beech stand located at middle elevations. On the other hand, thinning effects in mountain conditions were negligible. Thinning focusing on future stand quality cannot be commonly applied in artificially regenerated beech stands because of their worse initial quality and lower density. However, these stands show good growth and response to thinning, hence their management can be focused on maximising beech wood production.

  3. Modeling of SAR returns from a red pine stand

    Science.gov (United States)

    Lang, R. H.; Kilic, O.; Chauhan, N. S.; Ranson, J.

    1992-01-01

    Bright P-band radar returns from red pine forests have been observed on synthetic aperture radar (SAR) images in Bangor, Maine. A plot of red pine trees was selected for the characterization and modeling to understand the cause of the high P-band returns. The red pine stand under study consisted of mature trees. Diameter at breast height (DBH) measurements were made to determine stand density as a function of tree diameter. Soil moisture and bulk density measurements were taken along with ground rough surface profiles. Detailed biomass measurements of the needles, shoots, branches, and trunks were also taken. These site statistics have been used in a distorted Born approximation model of the forest. Computations indicate that the direct-reflected or the double-bounce contributions from the ground are responsible for the high observed P-band returns for HH polarization.

  4. An Empirical Analysis of the Physical Aptitude Exam as a Predictor of Performance on the Physical Readiness Test

    National Research Council Canada - National Science Library

    Patrick, Robert

    2000-01-01

    ... shuttle run, a standing longiump, and a kneeling basketball throw. The Physical Readiness Test, administered semi-annually to all naval personnel including midshipmen, consists of modified situps, pushups, and a 1.5-mile run...

  5. Refrigeration system having standing wave compressor

    Science.gov (United States)

    Lucas, Timothy S.

    1992-01-01

    A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

  6. The energy cost for balance control during upright standing

    NARCIS (Netherlands)

    Houdijk, J.H.P.; Fickert, R.; van Velzen, J.; van Bennekom, C.A.M.

    2009-01-01

    The aim of this study was to investigate whether balance control during a static upright standing task with and without balance perturbations elicits a significant and meaningful metabolic energy demand and to test whether this energy demand correlates with conventional posturography measures for

  7. Nonparametric test of consistency between cosmological models and multiband CMB measurements

    Energy Technology Data Exchange (ETDEWEB)

    Aghamousa, Amir [Asia Pacific Center for Theoretical Physics, Pohang, Gyeongbuk 790-784 (Korea, Republic of); Shafieloo, Arman, E-mail: amir@apctp.org, E-mail: shafieloo@kasi.re.kr [Korea Astronomy and Space Science Institute, Daejeon 305-348 (Korea, Republic of)

    2015-06-01

    We present a novel approach to test the consistency of the cosmological models with multiband CMB data using a nonparametric approach. In our analysis we calibrate the REACT (Risk Estimation and Adaptation after Coordinate Transformation) confidence levels associated with distances in function space (confidence distances) based on the Monte Carlo simulations in order to test the consistency of an assumed cosmological model with observation. To show the applicability of our algorithm, we confront Planck 2013 temperature data with concordance model of cosmology considering two different Planck spectra combination. In order to have an accurate quantitative statistical measure to compare between the data and the theoretical expectations, we calibrate REACT confidence distances and perform a bias control using many realizations of the data. Our results in this work using Planck 2013 temperature data put the best fit ΛCDM model at 95% (∼ 2σ) confidence distance from the center of the nonparametric confidence set while repeating the analysis excluding the Planck 217 × 217 GHz spectrum data, the best fit ΛCDM model shifts to 70% (∼ 1σ) confidence distance. The most prominent features in the data deviating from the best fit ΛCDM model seems to be at low multipoles  18 < ℓ < 26 at greater than 2σ, ℓ ∼ 750 at ∼1 to 2σ and ℓ ∼ 1800 at greater than 2σ level. Excluding the 217×217 GHz spectrum the feature at ℓ ∼ 1800 becomes substantially less significance at ∼1 to 2σ confidence level. Results of our analysis based on the new approach we propose in this work are in agreement with other analysis done using alternative methods.

  8. Stand-alone photovoltaic applications. Lessons learned

    International Nuclear Information System (INIS)

    Loois, G.; Van Hemert, B.

    1999-02-01

    The IEA Photovoltaic Power Systems Programme (PVPS) is one of the collaborative R and D agreements established within the IEA. The objective of Task III is to promote and facilitate the exchange of information and experiences in the field of PV Systems in Stand-alone and Island Applications (SAPV). The book focuses on the practical experiences gained, and does not aim to provide a complete manual on SAPV. When Task III started its activities in 1993, a collection of 50 'State of the art' projects was published in the book 'Examples of Stand-Alone Photovoltaic Systems'. This publication marked the base line for the work of the task. Now, in 1998, the showcases from each country demonstrate the lessons learned in five years of cooperation. The book consists of two parts. The first part contains eight chapters dealing with a specific aspect of stand-alone PV. The second part introduces 14 national showcase projects in a systematic presentation. Each chapter and showcase can be read independently from the rest of the book. Chapter 2, contributed by The Netherlands, analyses the market for stand-alone PV systems. It gives an overview of the 'traditional' application of stand-alone PV, which is the electrification of remote buildings and which has been addressed in depth in other publications. The focus is on the market niches of service applications that are also interesting for more densely populated areas, e.g. in industrialised countries. The United Kingdom illustrates the economic aspects in Chapter 3. Cost comparisons are made, but more important is the illustration of the non-financial considerations that make PV the preferred choice as a power source for many applications. Switzerland explores in Chapter 4 (financing aspects) different financing mechanisms, and financial policies used to overcome the initial cost barrier. Most of these approaches have been applied in developing countries rather than in the western world. Using various examples from all over the

  9. Using a standing-tree acoustic tool to identify forest stands for the production of mechanically-graded lumber.

    Science.gov (United States)

    Paradis, Normand; Auty, David; Carter, Peter; Achim, Alexis

    2013-03-12

    This study investigates how the use of a Hitman ST300 acoustic sensor can help identify the best forest stands to be used as supply sources for the production of Machine Stress-Rated (MSR) lumber. Using two piezoelectric sensors, the ST300 measures the velocity of a mechanical wave induced in a standing tree. Measurements were made on 333 black spruce (Picea mariana (Mill.) BSP) trees from the North Shore region, Quebec (Canada) selected across a range of locations and along a chronosequence of elapsed time since the last fire (TSF). Logs were cut from a subsample of 39 trees, and sawn into 77 pieces of 38 mm × 89 mm cross-section before undergoing mechanical testing according to ASTM standard D-4761. A linear regression model was developed to predict the static modulus of elasticity of lumber using tree acoustic velocity and stem diameter at 1.3 m above ground level (R2 = 0.41). Results suggest that, at a regional level, 92% of the black spruce trees meet the requirements of MSR grade 1650Fb-1.5E, whilst 64% and 34% meet the 2100Fb-1.8E and 2400Fb-2.0E, respectively. Mature stands with a TSF < 150 years had 11 and 18% more boards in the latter two categories, respectively, and therefore represented the best supply source for MSR lumber.

  10. Correlation between movement complexity during static standing and balance function in institutionalized older adults

    Directory of Open Access Journals (Sweden)

    Yamagata M

    2017-03-01

    Full Text Available Momoko Yamagata,1 Tome Ikezoe,1 Midori Kamiya,1 Mitsuhiro Masaki,2,3 Noriaki Ichihashi1 1Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, 2Department of Physical Therapy, 3Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan Purpose: Sample entropy (SampEn is an analysis to evaluate movement complexity of the center of pressure (COP. A lower value of SampEn indicates lower complexity of COP variability, that is, rigidity, and lower degrees of freedom. Previous studies reported the association of increased SampEn with improved standing balance ability in young subjects. However, no studies have examined these relationships among older adults. Thus, we aimed to investigate the relationship between SampEn and standing balance ability in older adults.Subjects and methods: The subjects were 33 institutionalized older adults (aged 82.2±6.5 years. COP during static standing was measured. The standard deviation (SD values of COP and SampEn in the sagittal and frontal planes were calculated using time series data. One-leg standing test (OLST, functional reach (FR test, and lateral reach (LR test were also measured to evaluate standing balance ability.Results: OLST, FR, and LR were 6.5±8.3 s, 19.8±5.9 cm, and 18.2±6.4 cm, respectively. Pearson correlation analysis revealed that SampEn in the sagittal plane significantly correlated with OLST (r=-0.35 and FR (r=-0.36. However, SampEn in the frontal plane and SD of COP in both sagittal and frontal planes had no relationship with any of the clinical balance tests.Conclusion: Lower SampEn implies rigidity for postural control. In the present study, it was found that lower SampEn in the sagittal plane was related to a higher balance function, which suggests that older adults utilized body rigidity to maintain postural stability as a compensative strategy. Keywords: older adults, posture, balance, standing, complexity

  11. The Influence of Residual Stand Densities on Regeneration in Sugar Maple Stands

    Science.gov (United States)

    Carl H. Tubbs

    1968-01-01

    Studies of regeneration 2, 5, and 10 years after cutting mature and overmature sugar maple stands to several residual densities show that (1) sugar maple is still the predominant species under all stand densities (2) nearly all regeneration reaching larger size classes became established before cutting (3) heavier cuttings (30, 50, and 70 square feet) are more rapidly...

  12. Kinematic Analysis of the Standing Long Jump in Children 6- to 12-Years-Old

    Science.gov (United States)

    Fernandez-Santos, Jorge R.; Gonzalez-Montesinos, Jose Luis; Ruiz, Jonatan R.; Jiménez-Pavón, David; Castro-Piñero, Jose

    2018-01-01

    The purpose of this study was to analyze the kinematic variables that determine the performance of the standing long jump in children 6- to 12-years-old. There were 121 healthy children (58 girls) recorded while they performed the standing long jump test. All kinematic variables showed a significant correlation with calculated jump distance and…

  13. Test facility for PLT TF coils

    International Nuclear Information System (INIS)

    Hearney, J.; File, J.; Dreskin, S.

    1975-01-01

    Past experience with the model C stellerator and other toroidal field devices indicates that mechanical and electrical tests of a toroidal field coil prior to maximum field operation of the device is prudent and desirable. This paper describes a test program for the PLT-TF coils. The test stand consists of one test coil, two background coils and a steel supporting structure. The three coil configuration produces a 67.5 kG field at the inner conductor (38 kG at the bore center) and simulates a 1/R field distribution in the bore of the test coil. The resolution of the field force system and resultant stresses within the test structure are discussed. A test procedure is described which maximizes the information obtained from a 100,000 pulse program

  14. A comparison of litter production in young and old baldcypress (Taxodium distichum L.) stands at Caddo Lake, Texas

    Science.gov (United States)

    McCoy, John W.; Draugelis-Dale, Rassa O.; Keeland, Bobby D.; Darville, Roy

    2010-01-01

    Aboveground primary productivity for cypress forests was assessed from measurements of litter production in two age groups and in two hydrological regimes (standing water and free-flowing). Caddo Lake, located in northeast Texas on the Texas-Louisiana border, offered a unique study site since it is dominated by extensive stands composed entirely of Taxodium distichum (L.) Rich, (baldcypress) in different age groups. Young stands (approximately 100 years old) are found along the shoreline and on shallow flooded islands. Old stands (-150 to 300 years old) are found in deeper water where they were continuously flooded. Litter production over three years from October 1998 to September 2001 was measured. Litter consisting of leaves, twigs, bark, reproductive parts, and Tillandsia usneoides (L.) L. (Spanish moss) was collected monthly using 0.5 m2 floating traps. Tree diameters were measured within 200 m2 circular plots in each stand. The young stands supported densities greater than 2,000 stems/ha and a mean stand basal area of 72.3 m2/ha, whereas old stands supported lower densities of about 500 stems/ha but with a similar mean stand basal area of 73.3 m2/ha. There was a significant difference between old and young stands for overall yearly litter production, averaging about 670 g/m2/yr in the young stands and 460 g/m2/yr in the old stands. Leaves and twigs were significantly greater in the young stands, while reproductive parts were higher in old stands. Litter collections between years or hydrological regimes were not significantly different.

  15. 24 CFR 206.37 - Credit standing.

    Science.gov (United States)

    2010-04-01

    ... CONVERSION MORTGAGE INSURANCE Eligibility; Endorsement Eligible Mortgagors § 206.37 Credit standing. Each mortgagor must have a general credit standing satisfactory to the Secretary. ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Credit standing. 206.37 Section 206...

  16. Three-dimensional instability of standing waves

    Science.gov (United States)

    Zhu, Qiang; Liu, Yuming; Yue, Dick K. P.

    2003-12-01

    We investigate the three-dimensional instability of finite-amplitude standing surface waves under the influence of gravity. The analysis employs the transition matrix (TM) approach and uses a new high-order spectral element (HOSE) method for computation of the nonlinear wave dynamics. HOSE is an extension of the original high-order spectral method (HOS) wherein nonlinear wave wave and wave body interactions are retained up to high order in wave steepness. Instead of global basis functions in HOS, however, HOSE employs spectral elements to allow for complex free-surface geometries and surface-piercing bodies. Exponential convergence of HOS with respect to the total number of spectral modes (for a fixed number of elements) and interaction order is retained in HOSE. In this study, we use TM-HOSE to obtain the stability of general three-dimensional perturbations (on a two-dimensional surface) on two classes of standing waves: plane standing waves in a rectangular tank; and radial/azimuthal standing waves in a circular basin. For plane standing waves, we confirm the known result of two-dimensional side-bandlike instability. In addition, we find a novel three-dimensional instability for base flow of any amplitude. The dominant component of the unstable disturbance is an oblique (standing) wave oriented at an arbitrary angle whose frequency is close to the (nonlinear) frequency of the original standing wave. This finding is confirmed by direct long-time simulations using HOSE which show that the nonlinear evolution leads to classical Fermi Pasta Ulam recurrence. For the circular basin, we find that, beyond a threshold wave steepness, a standing wave (of nonlinear frequency Omega) is unstable to three-dimensional perturbations. The unstable perturbation contains two dominant (standing-wave) components, the sum of whose frequencies is close to 2Omega. From the cases we consider, the critical wave steepness is found to generally decrease/increase with increasing radial

  17. Large coil test facility conceptual design report

    International Nuclear Information System (INIS)

    Nelms, L.W.; Thompson, P.B.; Mann, T.L.

    1978-02-01

    In the development of a superconducting toroidal field (TF) magnet for The Next Step (TNS) tokamak reactor, several different TF coils, about half TNS size, will be built and tested to permit selection of a design and fabrication procedure for full-scale TNS coils. A conceptual design has been completed for a facility to test D-shaped TF coils, 2.5 x 3.5-m bore, operating at 4-6 K, cooled either by boiling helium or by forced-flow supercritical helium. Up to six coils can be accommodated in a toroidal array housed in a single vacuum tank. The principal components and systems in the facility are an 11-m vacuum tank, a test stand providing structural support and service connections for the coils, a liquid nitrogen system, a system providing helium both as saturated liquid and at supercritical pressure, coils to produce a pulsed vertical field at any selected test coil position, coil power supplies, process instrumentation and control, coil diagnostics, and a data acquisition and handling system. The test stand structure is composed of a central bucking post, a base structure, and two horizontal torque rings. The coils are bolted to the bucking post, which transmits all gravity loads to the base structure. The torque ring structure, consisting of beams between adjacent coils, acts with the bucking structure to react all the magnetic loads that occur when the coils are energized. Liquid helium is used to cool the test stand structure to 5 K to minimize heat conduction to the coils. Liquid nitrogen is used to precool gaseous helium during system cooldown and to provide thermal radiation shielding

  18. Cellular composition of long-standing gingivitis and periodontitis lesions.

    Science.gov (United States)

    Thorbert-Mros, S; Larsson, L; Berglundh, T

    2015-08-01

    Insufficient information on the cellular composition of long-standing gingivitis lesions without signs of attachment loss makes an understanding of differences in cellular composition between "destructive" and "nondestructive" periodontal lesions difficult. The aim of the current study was to analyze differences in cell characteristics between lesions representing long-standing gingivitis and severe periodontitis. Two groups of patients were recruited. One group consisted of 36 patients, 33-67 years of age, with severe generalized periodontitis (periodontitis group). The second group consisted of 28 patients, 41-70 years of age, with overt signs of gingival inflammation but no attachment loss (gingivitis group). From each patient a gingival biopsy was obtained from one selected diseased site and prepared for immunohistochemical analysis. Periodontitis lesions were twice as large and contained significantly larger proportions, numbers and densities of cells positive for CD138 (plasma cells) and CD68 (macrophages) than did gingivitis lesions. The proportion of B cells that expressed the additional CD5 marker (B-1a cells) was significantly larger in periodontitis lesions than in gingivitis lesions. The densities of T cells and B cells did not differ between periodontitis lesions and gingivitis lesions. T cells were not the dominating cell type in gingivitis lesions, as B cells together with their subset plasma cells comprised a larger number and proportion than T cells. Periodontitis lesions at teeth with advanced attachment and bone loss exhibit quantitative and qualitative differences in relation to gingivitis lesions at teeth with no attachment and bone loss. It is suggested that the large number and high density of plasma cells are the hallmarks of advanced periodontitis lesions and the most conspicuous difference in relation to long-standing gingivitis lesions. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Research of explosives in an environment of high pressure and temperature using a new test stand

    Directory of Open Access Journals (Sweden)

    Jan Drzewiecki

    2015-01-01

    Full Text Available In this article the test stand for determining the blast abilities of explosives in high pressure and temperature conditions as well as the initial results of the research are presented. Explosives are used in rock burst and methane prevention to destroy precisely defined fragments of the rock mass where energy and methane are accumulated. Using this preventive method for fracturing the structure of the rocks which accumulate the energy or coal of the methane seam very often does not bring the anticipated results. It is because of the short range of destructive action of the post-blast gases around the blast hole. Evaluation of the blast dynamics of explosives in a test chamber, i.e. in the pressure and temperature conditions comparable to those found “in situ”, will enable evaluation of their real usefulness in commonly used mining hazard preventive methods. At the same time, it will enable the development of new designs of the explosive charges used for precisely determined mining hazards. In order to test the explosives for their use in difficult environmental conditions and to determine the characteristics of their explosion, a test chamber has been built. It is equipped with a system of sensors and a high-frequency recording system of pressure and temperature during a controlled explosion of an explosive charge. The results of the research will enable the development of new technologies for rock burst and methane prevention which will significantly increase workplace health and safety level. This paper presented results constitute the initial phase of research started in the middle of 2014.

  20. Acoustic radiation force on a sphere in standing and quasi-standing zero-order Bessel beam tweezers

    International Nuclear Information System (INIS)

    Mitri, F.G.

    2008-01-01

    Starting from the exact acoustic scattering from a sphere immersed in an ideal fluid and centered along the propagation axis of a standing or quasi-standing zero-order Bessel beam, explicit partial-wave representations for the radiation force are derived. A standing or a quasi-standing acoustic field is the result of propagating two equal or unequal amplitude zero-order Bessel beams, respectively, along the same axis but in opposite sense. The Bessel beam is characterized by the half-cone angle β of its plane wave components, such that β = 0 represents a plane wave. It is assumed here that the half-cone angle β for each of the counter-propagating acoustic Bessel beams is equal. Fluid, elastic and viscoelastic spheres immersed in water are treated as examples. Results indicate the capability of manipulating spherical targets based on their mechanical and acoustical properties. This condition provides an impetus for further designing acoustic tweezers operating with standing or quasi-standing Bessel acoustic waves. Potential applications include particle manipulation in micro-fluidic lab-on-chips as well as in reduced gravity environments

  1. Retrieving forest stand parameters from SAR backscatter data using a neural network trained by a canopy backscatter model

    International Nuclear Information System (INIS)

    Wang, Y.; Dong, D.

    1997-01-01

    It was possible to retrieve the stand mean dbh (tree trunk diameter at breast height) and stand density from the Jet Propulsion Laboratory (JPL) Airborne Synthetic Aperture Radar (AIRSAR) backscatter data by using threelayered perceptron neural networks (NNs). Two sets of NNs were trained by the Santa Barbara microwave canopy backscatter model. One set of the trained NNs was used to retrieve the stand mean dbh, and the other to retrieve the stand density. Each set of the NNs consisted of seven individual NNs for all possible combinations of one, two, and three radar wavelengths. Ground and multiple wavelength AIRSAR backscatter data from two ponderosa pine forest stands near Mt. Shasta, California (U.S.A.) were used to evaluate the accuracy of the retrievals. The r.m.s. and relative errors of the retrieval for stand mean dbh were 6.1 cm and 15.6 per cent for one stand (St2), and 3.1 cm and 6.7 per cent for the other stand (St11). The r.m.s. and relative errors of the retrieval for stand density were 71.2 treesha-1 and 23.0 per cent for St2, and 49.7 treesha-1 and 21.3 per cent for St11. (author)

  2. Beam property measurement of a 300-kV ion source test stand for a 1-MV electrostatic accelerator

    Science.gov (United States)

    Park, Sae-Hoon; Kim, Dae-Il; Kim, Yu-Seok

    2016-09-01

    The KOMAC (Korea Multi-purpose Accelerator Complex) has been developing a 300-kV ion source test stand for a 1-MV electrostatic accelerator for industrial purposes. A RF ion source was operated at 200 MHz with its matching circuit. The beam profile and emittance were measured behind an accelerating column to confirm the beam property from the RF ion source. The beam profile was measured at the end of the accelerating tube and at the beam dump by using a beam profile monitor (BPM) and wire scanner. An Allison-type emittance scanner was installed behind the beam profile monitor (BPM) to measure the beam density in phase space. The measurement results for the beam profile and emittance are presented in this paper.

  3. Performance of spinal cord injury individuals while standing with the Mohammad Taghi Karimi reciprocal gait orthosis (MTK-RGO)

    International Nuclear Information System (INIS)

    Karimi, Mohammad Taghi; Amiri, Pouya; Esrafilian, Amir; Sedigh, Jafar; Fatoye, Francis

    2013-01-01

    Most patients with spinal cord injury use a wheelchair to transfer from place to place, however they need to stand and walk with orthosis to improve their health status. Although many orthoses have been designed for paraplegic patients, they have experienced various problems while in use. A new type of reciprocal gait orthosis was designed in the Bioengineering Unit of Strathclyde University to solve the problems of the available orthoses. Since there was no research undertaken regarding testing of the new orthosis on paraplegic subjects, this study was aimed to evaluate the new orthosis during standing of paraplegic subjects. Five paraplegic patients with lesion level between T12 and L1 and aged matched normal subjects were recruited into this study. The stability of subjects was evaluated during quiet standing and while undertaking hand tasks during standing with the new orthosis and the knee ankle foot orthosis (KAFO). The difference between the performances of paraplegic subjects while standing with both orthoses, and between the function of normal and paraplegic subjects were compared using the paired t test and independent sample t test, respectively. The stability of paraplegic subjects in standing with the new orthosis was better than that of the KAFO orthosis (p < 0.05). Moreover, the force applied on the crutch differed between the orthoses. The functional performance of paraplegic subjects was better with the new orthosis compared with normal subjects. The performance of paraplegic subjects while standing with the new orthosis was better than the KAFO. Therefore, the new orthosis may be useful to improve standing and walking in patients with paraplegia.

  4. Reliability and fatigue characteristics of a standing hip isometric endurance protocol.

    Science.gov (United States)

    Mutchler, Jessica A; Weinhandl, Joshua T; Hoch, Matthew C; Van Lunen, Bonnie L

    2015-08-01

    Muscle fatigue is a common consideration when evaluating and rehabilitating athletic injuries. The presence of muscular fatigue has been previously determined by quantifying median frequency (MF) through a power spectral analysis on EMG signals collected throughout an endurance task. Research has not yet determined if a prolonged isometric test in a standing position generates muscular fatigue of the hip. The purpose of this study was to determine the reliability and fatigue characteristics of a standing hip isometric endurance test. Twenty healthy participants completed one 60-s Maximum Voluntary Isometric Contraction of standing hip flexion, extension, adduction, and abduction. MF of the participants' dominant limb rectus femoris (RF), biceps femoris (BF), gluteus maximus (GMax), gluteus medius (GMed) and adductor longus (ADD) was determined via surface electromyography during two sessions, 30-min apart. Reliability values (ICC2,1) were moderate-to-excellent for all time intervals of each action (FlexionRF: >0.80; ExtensionBF: >0.89; ExtensionGMax: >0.60; AdductionADD: >0.78; AbductionGMed: >0.60) and MF significantly decreased over time for all actions. Results suggest the endurance test is a reliable technique to generate muscular fatigue for hip flexion, extension, adduction and abduction. It can be used as a time efficient fatigue protocol specific to the RF, BF, GMax, ADD and GMed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Consistency test of the standard model

    International Nuclear Information System (INIS)

    Pawlowski, M.; Raczka, R.

    1997-01-01

    If the 'Higgs mass' is not the physical mass of a real particle but rather an effective ultraviolet cutoff then a process energy dependence of this cutoff must be admitted. Precision data from at least two energy scale experimental points are necessary to test this hypothesis. The first set of precision data is provided by the Z-boson peak experiments. We argue that the second set can be given by 10-20 GeV e + e - colliders. We pay attention to the special role of tau polarization experiments that can be sensitive to the 'Higgs mass' for a sample of ∼ 10 8 produced tau pairs. We argue that such a study may be regarded as a negative selfconsistency test of the Standard Model and of most of its extensions

  6. Muscular Activity and Fatigue in Lower-Limb and Trunk Muscles during Different Sit-To-Stand Tests.

    Directory of Open Access Journals (Sweden)

    Cristina Roldán-Jiménez

    Full Text Available Sit-to-stand (STS tests measure the ability to get up from a chair, reproducing an important component of daily living activity. As this functional task is essential for human independence, STS performance has been studied in the past decades using several methods, including electromyography. The aim of this study was to measure muscular activity and fatigue during different repetitions and speeds of STS tasks using surface electromyography in lower-limb and trunk muscles. This cross-sectional study recruited 30 healthy young adults. Average muscle activation, percentage of maximum voluntary contraction, muscle involvement in motion and fatigue were measured using surface electrodes placed on the medial gastrocnemius (MG, biceps femoris (BF, vastus medialis of the quadriceps (QM, the abdominal rectus (AR, erector spinae (ES, rectus femoris (RF, soleus (SO and the tibialis anterior (TA. Five-repetition STS, 10-repetition STS and 30-second STS variants were performed. MG, BF, QM, ES and RF muscles showed differences in muscle activation, while QM, AR and ES muscles showed significant differences in MVC percentage. Also, significant differences in fatigue were found in QM muscle between different STS tests. There was no statistically significant fatigue in the BF, MG and SO muscles of the leg although there appeared to be a trend of increasing fatigue. These results could be useful in describing the functional movements of the STS test used in rehabilitation programs, notwithstanding that they were measured in healthy young subjects.

  7. Muscular Activity and Fatigue in Lower-Limb and Trunk Muscles during Different Sit-To-Stand Tests.

    Science.gov (United States)

    Roldán-Jiménez, Cristina; Bennett, Paul; Cuesta-Vargas, Antonio I

    2015-01-01

    Sit-to-stand (STS) tests measure the ability to get up from a chair, reproducing an important component of daily living activity. As this functional task is essential for human independence, STS performance has been studied in the past decades using several methods, including electromyography. The aim of this study was to measure muscular activity and fatigue during different repetitions and speeds of STS tasks using surface electromyography in lower-limb and trunk muscles. This cross-sectional study recruited 30 healthy young adults. Average muscle activation, percentage of maximum voluntary contraction, muscle involvement in motion and fatigue were measured using surface electrodes placed on the medial gastrocnemius (MG), biceps femoris (BF), vastus medialis of the quadriceps (QM), the abdominal rectus (AR), erector spinae (ES), rectus femoris (RF), soleus (SO) and the tibialis anterior (TA). Five-repetition STS, 10-repetition STS and 30-second STS variants were performed. MG, BF, QM, ES and RF muscles showed differences in muscle activation, while QM, AR and ES muscles showed significant differences in MVC percentage. Also, significant differences in fatigue were found in QM muscle between different STS tests. There was no statistically significant fatigue in the BF, MG and SO muscles of the leg although there appeared to be a trend of increasing fatigue. These results could be useful in describing the functional movements of the STS test used in rehabilitation programs, notwithstanding that they were measured in healthy young subjects.

  8. Leaching characteristics of the metal waste form from the electrometallurgical treatment process: Product consistency testing

    International Nuclear Information System (INIS)

    Johnson, S. G.; Keiser, D. D.; Frank, S. M.; DiSanto, T.; Noy, M.

    1999-01-01

    Argonne National Laboratory is developing an electrometallurgical treatment for spent fuel from the experimental breeder reactor II. A product of this treatment process is a metal waste form that incorporates the stainless steel cladding hulls, zirconium from the fuel and the fission products that are noble to the process, i.e., Tc, Ru, Nb, Pd, Rh, Ag. The nominal composition of this waste form is stainless steel/15 wt% zirconium/1--4 wt% noble metal fission products/1--2 wt % U. Leaching results are presented from several tests and sample types: (1) 2 week monolithic immersion tests on actual metal waste forms produced from irradiated cladding hulls, (2) long term (>2 years) pulsed flow tests on samples containing technetium and uranium and (3) crushed sample immersion tests on cold simulated metal waste form samples. The test results will be compared and their relevance for waste form product consistency testing discussed

  9. Design and commissioning of Fermilab's vertical test stand for ILC SRF cavities.

    Energy Technology Data Exchange (ETDEWEB)

    Ozelis, Joseph P.; Carcagno, Ruben; Ginsburg, Camille M.; Huang, Yuenian; Norris, Barry; Peterson, Thomas; Poloubotko, Valeri; Rabehl, roger; Rakhno, Igor; Reid, Clark; Sergatskov, Dmitri A.; /Fermilab

    2007-06-01

    As part of its ILC program, Fermilab is developing a facility for vertical testing of SRF cavities. It operates at a nominal temperature of 2K, using a cryoplant that can supply LHe in excess of 20g/sec and provide bath pumping capacity of 125W at 2K. The below-grade cryostat consists of a vacuum vessel and LHe vessel, equipped with magnetic shielding to reduce the ambient magnetic field to <10mG. Internal fixed and external movable radiation shielding ensures that exposure to personnel is minimized. The facility features an integrated personnel safety system consisting of RF switches, interlocks, and area radiation monitors.

  10. VLE measurements using a static cell vapor phase manual sampling method accompanied with an empirical data consistency test

    International Nuclear Information System (INIS)

    Freitag, Joerg; Kosuge, Hitoshi; Schmelzer, Juergen P.; Kato, Satoru

    2015-01-01

    Highlights: • We use a new, simple static cell vapor phase manual sampling method (SCVMS) for VLE (x, y, T) measurement. • The method is applied to non-azeotropic, asymmetric and two-liquid phase forming azeotropic binaries. • The method is approved by a data consistency test, i.e., a plot of the polarity exclusion factor vs. pressure. • The consistency test reveals that with the new SCVMS method accurate VLE near ambient temperature can be measured. • Moreover, the consistency test approves that the effect of air in the SCVMS system is negligible. - Abstract: A new static cell vapor phase manual sampling (SCVMS) method is used for the simple measurement of constant temperature x, y (vapor + liquid) equilibria (VLE). The method was applied to the VLE measurements of the (methanol + water) binary at T/K = (283.2, 298.2, 308.2 and 322.9), asymmetric (acetone + 1-butanol) binary at T/K = (283.2, 295.2, 308.2 and 324.2) and two-liquid phase forming azeotropic (water + 1-butanol) binary at T/K = (283.2 and 298.2). The accuracy of the experimental data was approved by a data consistency test, that is, an empirical plot of the polarity exclusion factor, β, vs. the system pressure, P. The SCVMS data are accurate, because the VLE data converge to the same lnβ vs. lnP straight line determined from conventional distillation-still method and a headspace gas chromatography method

  11. Neural network modelling of rainfall interception in four different forest stands

    Directory of Open Access Journals (Sweden)

    İbrahim Yurtseven

    2013-11-01

    Full Text Available The objective of this study is to reveal whether it is possible to predict rainfall, through fall and stem flow in forest ecosystems with less effort, using several measurements of rainfall interception (hereafter ‘interception’ and an artificial neural network based linear regression model (ANN model. To this end, the Kerpe Research Forest in the province of Kocaeli, which houses stands of mixed deciduous-broadleaf forest (Castanea sativa Mill., Fagusorientalis Lipsky, Quercus spp., black pine (Pinus nigra Arnold, maritime pine (Pinus pinaster Aiton and Monterey pine (Pinus radiata D. Don, was selected study site. Four different forest stands were observed for a period of two years, during which rainfall, throughfall and stemflow measurements were conducted. These measurements were separately calculated for each individual stand, based on interception values and the use of stemflow data in strict accordance with the rainfall data, and the measured throughfall interceptionvalues were compared with values estimated by the ANN model.In this comparison, 70% of the total data was used for testing, and 30% was used for estimation and performance evaluation. No significant differences were found between values predicted with the help of the model and the measured values. In other words, interception values predicted by the ANN models were parallel with the measured values. In this study, the most success was achieved with the models of the Monterey pine stand (r2 = 0.9968; Mean Squared Error MSE = 0.16 and the mixed deciduous forest stand (r2 = 0.9964; MSE = 0.08, followed by models of the maritime pine stand (r2 = 0.9405; MSE = 1.27 and the black pine stand (r2 = 0.843, MSE = 17.36.

  12. Modeling and Experimental Test of Grid-Tied Photovoltaic Cell Emulating System in the Stand-alone Mode

    Directory of Open Access Journals (Sweden)

    Vu Minh Phap

    2017-06-01

    Full Text Available In recent decades, generation of electricity from solar arrays has been increased to meet the world's growing energy demand. However, the utilization rate of the power conditioner in the grid-tied solar power system is low because the operation of solar panels is dependent on sunlight. Thus, we studied the method that the small scale wind power generating system in size from a few hundred watts to two or three kilowatts can be connected to the grid-tied power conditioner of the solar power system for residential applications with low power ratings (single phase, size is limited to 10kW by emulating characteristic of the solar panel. In this paper, we introduce the application of the grid-tied PV cell emulating system in the stand-alone mode to improve the utilization rate of the power conditioner. The simulation and experimental test results verify that the PV cell emulating system can operate the power conditioner of the gridtied solar power system.

  13. Benchmarking the Collocation Stand-Alone Library and Toolkit (CSALT)

    Science.gov (United States)

    Hughes, Steven; Knittel, Jeremy; Shoan, Wendy; Kim, Youngkwang; Conway, Claire; Conway, Darrel J.

    2017-01-01

    This paper describes the processes and results of Verification and Validation (VV) efforts for the Collocation Stand Alone Library and Toolkit (CSALT). We describe the test program and environments, the tools used for independent test data, and comparison results. The VV effort employs classical problems with known analytic solutions, solutions from other available software tools, and comparisons to benchmarking data available in the public literature. Presenting all test results are beyond the scope of a single paper. Here we present high-level test results for a broad range of problems, and detailed comparisons for selected problems.

  14. Forest volume-to-biomass models and estimates of mass for live and standing dead trees of U.S. forests.

    Science.gov (United States)

    James E. Smith; Linda S. Heath; Jennifer C. Jenkins

    2003-01-01

    Includes methods and equations for nationally consistent estimates of tree-mass density at the stand level (Mg/ha) as predicted by growing-stock volumes reported by the USDA Forest Service for forests of the conterminous United States. Developed for use in FORCARB, a carbon budget model for U.S. forests, the equations also are useful for converting plot-, stand- and...

  15. Using the Functional Reach Test for Probing the Static Stability of Bipedal Standing in Humanoid Robots Based on the Passive Motion Paradigm

    Directory of Open Access Journals (Sweden)

    Jacopo Zenzeri

    2013-01-01

    Full Text Available The goal of this paper is to analyze the static stability of a computational architecture, based on the Passive Motion Paradigm, for coordinating the redundant degrees of freedom of a humanoid robot during whole-body reaching movements in bipedal standing. The analysis is based on a simulation study that implements the Functional Reach Test, originally developed for assessing the danger of falling in elderly people. The study is carried out in the YARP environment that allows realistic simulations with the iCub humanoid robot.

  16. Iterative development of Stand Up Australia: a multi-component intervention to reduce workplace sitting

    Science.gov (United States)

    2014-01-01

    Background Sitting, particularly in prolonged, unbroken bouts, is widespread within the office workplace, yet few interventions have addressed this newly-identified health risk behaviour. This paper describes the iterative development process and resulting intervention procedures for the Stand Up Australia research program focusing on a multi-component workplace intervention to reduce sitting time. Methods The development of Stand Up Australia followed three phases. 1) Conceptualisation: Stand Up Australia was based on social cognitive theory and social ecological model components. These were operationalised via a taxonomy of intervention strategies and designed to target multiple levels of influence including: organisational structures (e.g. via management consultation), the physical work environment (via provision of height-adjustable workstations), and individual employees (e.g. via face-to-face coaching). 2) Formative research: Intervention components were separately tested for their feasibility and acceptability. 3) Pilot studies: Stand Up Comcare tested the integrated intervention elements in a controlled pilot study examining efficacy, feasibility and acceptability. Stand Up UQ examined the additional value of the organisational- and individual-level components over height-adjustable workstations only in a three-arm controlled trial. In both pilot studies, office workers’ sitting time was measured objectively using activPAL3 devices and the intervention was refined based on qualitative feedback from managers and employees. Results Results and feedback from participants and managers involved in the intervention development phases suggest high efficacy, acceptance, and feasibility of all intervention components. The final version of the Stand Up Australia intervention includes strategies at the organisational (senior management consultation, representatives consultation workshop, team champions, staff information and brainstorming session with information

  17. Equipment for linking source stand and film holder carriage

    International Nuclear Information System (INIS)

    Fajt, P.; Zeman, M.

    1987-01-01

    A device is described for precision link-up of a source stand provided with a spring-loaded cam and a film holder carriage provided with an arm with catches. The catches are mechanically connected to a control device firmly connected to the bottom part of the film holder carriage arm. The cam whose extended part is slidably mounted in the cover guide is secured in position with springs fitted from both sides. The control device consists of an electromagnet with armature connected to the control device pull-rod. The pull-rod provides mechanical connection of the catches and the control device. Upon pressing the pushbutton, the catches automatically engage the film holder cariage arm so that the motorized source stand operates without connection to the carriage. This significantly facilitates the operation of the equipment and reduces physical effort of the technician. The most significant advantage is the possibility of immediate change in operation mode. (J.B.). 5 figs

  18. Measuring standing balance in multiple sclerosis: Further progress towards an automatic and reliable method in clinical practice.

    Science.gov (United States)

    Keune, Philipp M; Young, William R; Paraskevopoulos, Ioannis T; Hansen, Sascha; Muenssinger, Jana; Oschmann, Patrick; Müller, Roy

    2017-08-15

    Balance deficits in multiple sclerosis (MS) are often monitored by means of observer-rated tests. These may provide reliable data, but may also be time-consuming, subject to inter-rater variability, and potentially insensitive to mild fluctuations throughout the clinical course. On the other hand, laboratory assessments are often not available. The Nintendo Wii Balance Board (WBB) may represent a low-cost solution. The purpose of the current study was to examine the methodological quality of WBB data in MS (internal consistency, test-retest reliability), convergent validity with observer-rated tests (Berg Balance Scale, BBS; Timed-Up and Go Test, TUG), and discriminative validity concerning clinical status (Expanded Disability Status Scale, EDSS). Standing balance was assessed with the WBB for 4min in 63 MS patients at two assessment points, four months apart. Additionally, patients were examined with the BBS, TUG and the EDSS. A period of 4min on the WBB provided data characterized by excellent internal consistency and test-retest reliability. Significant correlations between WBB data and results of the BBS and TUG were obtained after merely 2min on the board. An EDSS median-split revealed that higher EDSS values (>3) were associated with significantly increased postural sway on the WBB. WBB measures reflecting postural sway are methodologically robust in MS, involving excellent internal consistency and test-retest reliability. They are also characterized by convergent validity with other considerably lengthier observer-rated balance measures (BBS) and sensitive to broader clinical characteristics (EDSS). The WBB may hence represent an effective, easy-to-use monitoring tool for MS patients in clinical practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. FINE ROOT TURNOVER IN PONDEROSA PINE STANDS OF DIFFERENT AGES: FIRST-YEAR RESULTS

    Science.gov (United States)

    Root minirhizotron tubs were installed in two ponderosa pine (Pinus ponderosa Laws.) Stands of different ages to examine patterns of root growth and death. The old-growth site (OS) consists of a mixture of old (>250 years) and young trees (ca.45 yrs)< and is located near clamp S...

  20. Unipedal standing exercise and hip bone mineral density in postmenopausal women: a randomized controlled trial.

    Science.gov (United States)

    Sakai, Akinori; Oshige, Toshihisa; Zenke, Yukichi; Yamanaka, Yoshiaki; Nagaishi, Hitoshi; Nakamura, Toshitaka

    2010-01-01

    The aim of this study was to test the effect of unipedal standing exercise on bone mineral density (BMD) of the hip in postmenopausal women. Japanese postmenopausal women (n = 94) were assigned at random to an exercise or control group (no exercise). The 6-month exercise program consisted of standing on a single foot for 1 min per leg 3 times per day. BMD of the hip was measured by dual-energy X-ray absorptiometry. There was no significant difference in age and baseline hip BMD between the exercise group (n = 49) and control group (n = 45). Exercise did not improve hip BMD compared with the control group. Stepwise regression analysis identified old age as a significant determinant (p = 0.034) of increased hip total BMD at 6 months after exercise. In 31 participants aged >/=70 years, the exercise group (n = 20) showed significant increase in the values of hip BMD at the areas of total (p = 0.008), intertrochanteric (p = 0.023), and Ward's triangle (p = 0.032). The same parameters were decreased in the control group (n = 11). The percent changes in hip BMD of the exercise group were not significantly different from those of the control group either in the participants with low baseline hip total BMD ( or =80% of the young adult mean). In conclusion, unipedal standing exercise for 6 months did not improve hip BMD in Japanese postmenopausal women. Effect of exercise on hip total BMD was age dependent. In participants aged > or =70 years, the exercise significantly increased hip total BMD.

  1. Measuring Diagnostic Stand for Experimental Researches in Technology Machining

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2014-01-01

    Full Text Available The paper reviews applied techniques, methods, and structure of the control and measuring means to conduct experimental and scientific researches of cutting processes. Existing research methods in cutting the metals are divided by features, such as essence of methods, the number of records of physical indicators, the number of studied factors, duration of tests. The groups of methods are briefly characterized.The chair "Tool Engineering and Technologies" of BMSTU developed and made a diagnostic stand of control and measurements for conducting research activities in the field of materials processing technology by cutting to define rational technological decisions, when machining, and carry out an analysis of efficiency and economic feasibility of made decisions. The diagnostic stand contains modern the electronic equipment. Record of measuring parameters is made in real time with a possibility for visual representation of read results and mathematical and statistical processing of measurement results. The stand can be used in research laboratories of machine-building enterprises, laboratories of higher education institutions, and other scientific divisions.The paper presents a justification that the stand is reasonable to use for the following: completion and choice of rational cutting modes, workability assessment of new constructional materials, technical and operational characteristics of the processed surfaces, and operational properties of the cutting tools of various producers, choice of optimum geometrical parameters of the cutting tools and brands of the lubricant cooling technological means, as well as the energy consumption for the chosen machining process. The stand allows us to make an assessment of wear resistance and tribology-technical characteristics of tool materials, as well as an accuracy, rigidity, vibration stability of machines, both new and being in operation.

  2. Fertilizing of mixed stands in a smoke-damaged region of the Erzgebirge range

    Energy Technology Data Exchange (ETDEWEB)

    Trillmich, H D

    1969-01-01

    Three mixed stands established in a S.E. German area of chronic pollution (no lichens were found in the stands) in 1933 to 1941 responded positively to fertilizers (PKCaMg in 1938 to 1942 and NPKCaMg in 1960 to 1964). Scots Pine responded less than Norway Spruce, Larch, and Beech, and differences between species affected stand structure. Tests on Scots Pine and Norway Spruce showed better color, weight, length and number of needles, compared with untreated controls, but only in Pine was there an increase in the number of older needles. Analyses of Spruce needles showed increases in nutrient contents vs. untreated controls (which showed no deficiencies, except perhaps of N). 11 references, 12 tables.

  3. Mechanized systems for early stand tending in central and eastern Canada

    Energy Technology Data Exchange (ETDEWEB)

    Ryans, M.; St-Amour, M. [Forest Engineering Research Inst. of Canada, Pointe Claire, PQ (Canada)

    1996-12-31

    Machines are currently being used for early stand tending in central and eastern Canada, but account for only 1 to 2% of the annual total for mechanical treatments (including manual and motor-manual operations). Selective and non-selective systems are used, depending on the application and stand conditions. Plantation cleaning operations and precommercial thinning (spacing) of naturally regenerated and seeded stands have been mechanized. Selective methods, primarily for plantation cleaning, use equipment with specialized prime movers, booms and controls, and cutting heads. This paper describes the Canadian experience to date based on FERIC`s studies of successful and unsuccessful operations, and lists the key features of a machine suitable for use in selective treatments. Strip precommercial thinning is used in denser natural stands, but limited improvements in crop-tree growth occur unless a motor-manual follow-up releases crop trees in the leave strips. Most off-the-shelf brushcutting equipment is not optimal for this application, primarily because it is too wide to meet local spacing prescriptions. Some applications such as the spacing of older natural stands have proven difficult to mechanize. Technical, biological, operational , regulatory, economic and social constraints prevent wider use of mechanized systems. Nonetheless, some machines are in operational use, and mechanized plantation cleaning is tested in some regions as an alternative to herbicides. 11 refs, 2 figs, 1 tab

  4. Development of seismic design method for free standing rack and applicability to Japanese nuclear power plant

    International Nuclear Information System (INIS)

    Takaki, Yu; Taniguchi, Katsuhiko; Kishimoto, Junichi; Iwasaki, Akihisa; Nekomoto, Yoshitsugu; Kuga, Tohru; Kameyama, Masashi

    2017-01-01

    Free standing racks which are not anchored to the pool floor nor walls have never been adopted in Japan. Under an earthquake, behaviors of free standing racks are nonlinear and involve a complex combination of motions (sliding, rocking, and twisting) and impacts between a fuel assembly and the fuel cell walls and between a pit floor and rack pedestals. To predict a seismic response of free standing racks, the seismic analysis requires careful considerations of these complex phenomena (sliding, rocking, and twisting), fluid coupling effects and frictional effects. We carried out seismic experiments on the full-scale rack model in both water and dry conditions and obtained the fundamental data about behavior of free standing racks (sliding, and rocking motions). We have developed the nonlinear dynamic analysis method to predict seismic response of free standing racks utilizing the full-scale test result and verified the analysis evaluation method of free standing rack by comparison between analysis results and experimental data. Furthermore, we applied the seismic design method to the free standing rack in the Japanese nuclear plant (Mihama nuclear power station Unit 3), and verified that the free standing rack was applicable to Japanese nuclear plant. (author)

  5. Neural network modelling of rainfall interception in four different forest stands

    Directory of Open Access Journals (Sweden)

    Ibrahim Yurtseven

    2013-12-01

    Full Text Available The objective of this study is to reveal whether it is possible to predict rainfall, throughfall and stemflow in forest ecosystems with less effort, using several measurements of rainfall interception (hereafter ‘interception’ and an artificial neural network based linear regression model (ANN model. To this end, the Kerpe Research Forest in the province of Kocaeli, which houses stands of mixed deciduous-broadleaf forest (Castanea sativa Mill., Fagus orientalis Lipsky, Quercus spp., black pine (Pinus nigra Arnold, maritime pine (Pinus pinaster Aiton and Monterey pine (Pinus radiata D. Don, was selected study site. Four different forest stands were observed for a period of two years, during which rainfall, throughfall and stemflow measurements were conducted. These measurements were separately calculated for each individual stand, based on interception values and the use of stemflow data in strict accordance with the rainfall data, and the measured throughfall interception values were compared with values estimated by the ANN model. In this comparison, 70% of the total data was used for testing, and 30% was used for estimation and performance evaluation. No significant differences were found between values predicted with the help of the model and the measured values. In other words, interception values predicted by the ANN models were parallel with the measured values. In this study, the most success was achieved with the models of the Monterey pine stand (r2 = 0.9968; Mean Squared Error MSE = 0.16 and the mixed deciduous forest stand (r2 = 0.9964; MSE = 0.08, followed by models of the maritime pine stand (r2 = 0.9405; MSE = 1.27 and the black pine stand (r2 = 0.843, MSE = 17.36.

  6. Canopy transpiration of pure and mixed forest stands with variable abundance of European beech

    Science.gov (United States)

    Gebauer, Tobias; Horna, Viviana; Leuschner, Christoph

    2012-06-01

    SummaryThe importance of tree species identity and diversity for biogeochemical cycles in forests is not well understood. In the past, forestry has widely converted mixed forests to pure stands while contemporary forest policy often prefers mixed stands again. However, the hydrological consequences of these changes remain unclear. We tested the hypotheses (i) that significant differences in water use per ground area exist among the tree species of temperate mixed forests and that these differences are more relevant for the amount of stand-level canopy transpiration (Ec) than putative complementarity effects of tree water use, and (ii) that the seasonal patterns of Ec in mixed stands are significantly influenced by the identity of the present tree species. We measured xylem sap flux during 2005 (average precipitation) and 2006 (relatively dry) synchronously in three nearby old-growth forest stands on similar soil differing in the abundance of European beech (pure beech stand, 3-species stand with 70% beech, 5-species stand with sapwood area basis, reflecting a considerable variation in hydraulic architecture and leaf conductance regulation among the co-existing species. Moreover, transpiration per crown projection area (ECA) also differed up to 5-fold among the different species in the mixed stands, probably reflecting contrasting sapwood/crown area ratios. We conclude that Ec is not principally higher in mixed forests than in pure beech stands. However, tree species-specific traits have an important influence on the height of Ec and affect its seasonal variation. Species with a relatively high ECA (notably Tilia) may exhaust soil water reserves early in summer, thereby increasing drought stress in dry years and possibly reducing ecosystem stability in mixed forests.

  7. Design and Calibration Tests of an Active Sound Intensity Probe

    Directory of Open Access Journals (Sweden)

    Thomas Kletschkowski

    2008-01-01

    Full Text Available The paper presents an active sound intensity probe that can be used for sound source localization in standing wave fields. The probe consists of a sound hard tube that is terminated by a loudspeaker and an integrated pair of microphones. The microphones are used to decompose the standing wave field inside the tube into its incident and reflected part. The latter is cancelled by an adaptive controller that calculates proper driving signals for the loudspeaker. If the open end of the actively controlled tube is placed close to a vibrating surface, the radiated sound intensity can be determined by measuring the cross spectral density between the two microphones. A one-dimensional free field can be realized effectively, as first experiments performed on a simplified test bed have shown. Further tests proved that a prototype of the novel sound intensity probe can be calibrated.

  8. Quantitative assessment of exposure and risk for three carcinogenics in long-standing pollution sites

    International Nuclear Information System (INIS)

    Wichmann, H.E.; Wuppertal Univ.; Ihme, W.; Mekel, O.C.L.; Wuppertal Univ.

    1993-01-01

    The project attempts a quantitative assessment of risks for three carcinogenics that are common in sites of long-standing pollution. Benzo(a)pyrene stands for the group of polycyclic aromatic hydrocarbons, cadmium for heavy metals, and benzene for volatile aromatic compounds. The report discusses the general fundamentals of exposure and risk assessment. The exposure model is described in detail and applied to the three test substances. (orig./MG) [de

  9. Transformation of solar radiation in Norway spruce stands into produced biomass - the effect of stand density

    International Nuclear Information System (INIS)

    Marková, I.; Marek, M.V.; Pokorný, R.

    2011-01-01

    The present paper is focused on the assessment of the effects of stand density and leaf area development on radiation use efficiency in the mountain cultivated Norway spruce stand. The young even-aged (17-years-old in 1998) plantation of Norway spruce was divided into two experimental plots differing in their stand density in 1995. During the late spring of 2001 next cultivating high-type of thinning of 15% intensity in a reduction of stocking density was performed. The PAR regime of investigated stands was continually measured since 1992. Total aboveground biomass (TBa) and TBa increment were obtained on the basis of stand inventory. The dynamic of LAI development showed a tendency to be saturated, i.e. the LAI value close to 11 seems to be maximal for the local conditions of the investigated mountain cultivated Norway spruce stand in the Beskids Mts. Remarkable stimuli (up to 17%) of LAI formation were started in 2002, i.e. as an immediate response to thinning. Thus, the positive effect of thinning on LAI increase was confirmed. The data set of absorbed PAR and produced TBa in the period 1998-2003 was processed by the linear regression of Monteith's model, which provided the values of the coefficient of solar energy conversion efficiency into biomass formation. The differences in biomass formation values between the dense and sparse plot after thinning amounted to 18%

  10. Inventory of aspen trees in spruce dominated stands in conservation area

    Directory of Open Access Journals (Sweden)

    Matti Maltamo

    2015-05-01

    Full Text Available Background The occurrence of aspen trees increases the conservation value of mature conifer dominated forests. Aspens typically occur as scattered individuals among major tree species, and therefore the inventory of aspens is challenging. Methods We characterized aspen populations in a boreal nature reserve using diameter distribution, spatial pattern, and forest attributes: volume, number of aspens, number of large aspen stems and basal area median diameter. The data were collected from three separate forest stands in Koli National Park, eastern Finland. At each site, we measured breast height diameter and coordinates of each aspen. The comparison of inventory methods of aspens within the three stands was based on simulations with mapped field data. We mimicked stand level inventory by locating varying numbers of fixed area circular plots both systematically and randomly within the stands. Additionally, we also tested if the use of airborne laser scanning (ALS data as auxiliary information would improve the accuracy of the stand level inventory by applying the probability proportional to size sampling to assist the selection of field plot locations. Results The results showed that aspens were always clustered, and the diameter distributions indicated different stand structures in the three investigated forest stands. The reliability of the volume and number of large aspen trees varied from relative root mean square error figures above 50% with fewer sample plots (5–10 to values of 25%–50% with 10 or more sample plots. Stand level inventory estimates were also able to detect spatial pattern and the shape of the diameter distribution. In addition, ALS-based auxiliary information could be useful in guiding the inventories, but caution should be used when applying the ALS-supported inventory technique. Conclusions This study characterized European aspen populations for the purposes of monitoring and management of boreal conservation areas. Our

  11. [Effects of crop tree release on stand growth and stand structure of Cunninghamia lanceolata plantation].

    Science.gov (United States)

    Wu, Jian-qiang; Wang, Yi-xiang; Yang, Yi; Zhu, Ting-ting; Zhu, Xu-dan

    2015-02-01

    Crop trees were selected in a 26-year-old even-aged Cunninghamia lanceolata plantation in Lin' an, and compared in plots that were released and unreleased to examine growth and structure responses for 3 years after thinning. Crop tree release significantly increased the mean increments of diameter and volume of individual tree by 1.30 and 1.25 times relative to trees in control stands, respectively. The increments of diameter and volume of crop trees were significantly higher than those of general trees in thinning plots, crop trees and general trees in control plots, which suggested that the responses from different tree types to crop tree release treatment were different. Crop tree release increased the average distances of crop trees to the nearest neighboring trees, reducing competition among crop trees by about 68.2%. 3-year stand volume increment for thinning stands had no significant difference with that of control stands although the number of trees was only 81.5% of the control. Crop trees in thinned plots with diameters over than 14 cm reached 18.0% over 3 years, compared with 12.0% for trees without thinning, suggesting that crop tree release benefited the larger individual trees. The pattern of tree locations in thinning plots tended to be random, complying with the rule that tree distribution pattern changes with growth. Crop tree release in C. lanceolata plantation not only promoted the stand growth, but also optimized the stand structure, benefiting crop trees sustained rapid growth and larger diameter trees production.

  12. Estimating Stand Volume and Above-Ground Biomass of Urban Forests Using LiDAR

    Directory of Open Access Journals (Sweden)

    Vincenzo Giannico

    2016-04-01

    Full Text Available Assessing forest stand conditions in urban and peri-urban areas is essential to support ecosystem service planning and management, as most of the ecosystem services provided are a consequence of forest stand characteristics. However, collecting data for assessing forest stand conditions is time consuming and labor intensive. A plausible approach for addressing this issue is to establish a relationship between in situ measurements of stand characteristics and data from airborne laser scanning (LiDAR. In this study we assessed forest stand volume and above-ground biomass (AGB in a broadleaved urban forest, using a combination of LiDAR-derived metrics, which takes the form of a forest allometric model. We tested various methods for extracting proxies of basal area (BA and mean stand height (H from the LiDAR point-cloud distribution and evaluated the performance of different models in estimating forest stand volume and AGB. The best predictors for both models were the scale parameters of the Weibull distribution of all returns (except the first (proxy of BA and the 95th percentile of the distribution of all first returns (proxy of H. The R2 were 0.81 (p < 0.01 for the stand volume model and 0.77 (p < 0.01 for the AGB model with a RMSE of 23.66 m3·ha−1 (23.3% and 19.59 Mg·ha−1 (23.9%, respectively. We found that a combination of two LiDAR-derived variables (i.e., proxy of BA and proxy of H, which take the form of a forest allometric model, can be used to estimate stand volume and above-ground biomass in broadleaved urban forest areas. Our results can be compared to other studies conducted using LiDAR in broadleaved forests with similar methods.

  13. Strength and stiffness assessment of standing trees using a nondestructive stress wave technique.

    Science.gov (United States)

    Xiping. Wang; Robert J. Ross; Michael. McClellan; R. James. Barbour; John R. Erickson; John W. Forsman; Gary D. McGinnis

    Natureas engineering of wood through genetics, stand conditions, and environment creates wide variability in wood as a material, which in turn introduces difficulties in wood processing and utilization. Manufacturers sometimes find it difficult to consistently process wood into quality products because of its wide range of properties. The primary objective of this...

  14. Evaluation of uniformity and noise consistency test in computerized tomography; Avaliacao do teste de constancia de uniformidade e ruido em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Garrafiel, Fabricio N.; Lykawka, Rochelle; Bacelar, Alexandre; Anes, Mauricio [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil); Alva-Sanchez, Mirko S.; Pianoschi, Thatiane [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil)

    2016-07-01

    The quality control in computed tomography (CT) includes constancy tests concerning CT number measured in a water tank and its response as uniformity, noise and accuracy. Differences to It's performance limits and frequency established by the national legislation and the manufacturers are well known. The objective of this study was to evaluate these tests proceeding the periodicity of national legislation. The tests were conducted over a three equipment of different manufacturers. Each equipment has acquisition parameters and specific phantoms. The equipment presented adequate performance and consistency when compared their results to the limits determined by manufacturers and national legislation. Thus, it is important to evaluate these differences and tailor the testing protocols to meet the established quality requirements. (author)

  15. Accounting for density reduction and structural loss in standing dead trees: Implications for forest biomass and carbon stock estimates in the United States

    Directory of Open Access Journals (Sweden)

    Domke Grant M

    2011-11-01

    Full Text Available Abstract Background Standing dead trees are one component of forest ecosystem dead wood carbon (C pools, whose national stock is estimated by the U.S. as required by the United Nations Framework Convention on Climate Change. Historically, standing dead tree C has been estimated as a function of live tree growing stock volume in the U.S.'s National Greenhouse Gas Inventory. Initiated in 1998, the USDA Forest Service's Forest Inventory and Analysis program (responsible for compiling the Nation's forest C estimates began consistent nationwide sampling of standing dead trees, which may now supplant previous purely model-based approaches to standing dead biomass and C stock estimation. A substantial hurdle to estimating standing dead tree biomass and C attributes is that traditional estimation procedures are based on merchantability paradigms that may not reflect density reductions or structural loss due to decomposition common in standing dead trees. The goal of this study was to incorporate standing dead tree adjustments into the current estimation procedures and assess how biomass and C stocks change at multiple spatial scales. Results Accounting for decay and structural loss in standing dead trees significantly decreased tree- and plot-level C stock estimates (and subsequent C stocks by decay class and tree component. At a regional scale, incorporating adjustment factors decreased standing dead quaking aspen biomass estimates by almost 50 percent in the Lake States and Douglas-fir estimates by more than 36 percent in the Pacific Northwest. Conclusions Substantial overestimates of standing dead tree biomass and C stocks occur when one does not account for density reductions or structural loss. Forest inventory estimation procedures that are descended from merchantability standards may need to be revised toward a more holistic approach to determining standing dead tree biomass and C attributes (i.e., attributes of tree biomass outside of sawlog

  16. Stand structure modulates the long-term vulnerability of Pinus halepensis to climatic drought in a semiarid Mediterranean ecosystem.

    Science.gov (United States)

    Moreno-Gutiérrez, Cristina; Battipaglia, Giovanna; Cherubini, Paolo; Saurer, Matthias; Nicolás, Emilio; Contreras, Sergio; Querejeta, José Ignacio

    2012-06-01

    We investigated whether stand structure modulates the long-term physiological performance and growth of Pinus halepensis Mill. in a semiarid Mediterranean ecosystem. Tree radial growth and carbon and oxygen stable isotope composition of latewood (δ(13)C(LW) and δ(18)O(LW), respectively) from 1967 to 2007 were measured in P. halepensis trees from two sharply contrasting stand types: open woodlands with widely scattered trees versus dense afforested stands. In both stand types, tree radial growth, δ(13)C(LW) and δ(18)O(LW) were strongly correlated with annual rainfall, thus indicating that tree performance in this semiarid environment is largely determined by inter-annual changes in water availability. However, trees in dense afforested stands showed consistently higher δ(18)O(LW) and similar δ(13)C(LW) values compared with those in neighbouring open woodlands, indicating lower stomatal conductance and photosynthesis rates in the former, but little difference in water use efficiency between stand types. Trees in dense afforested stands were more water stressed and showed lower radial growth, overall suggesting greater vulnerability to drought and climate aridification compared with trees in open woodlands. In this semiarid ecosystem, the negative impacts of intense inter-tree competition for water on P. halepensis performance clearly outweigh potential benefits derived from enhanced infiltration and reduced run-off losses in dense afforested stands. © 2011 Blackwell Publishing Ltd.

  17. Stand quality management in a late-rotation, red oak-sweetgum stand in east Mississippi: preliminary results following thinning

    Science.gov (United States)

    James S. Meadows; Daniel A. Skojac

    2012-01-01

    Stand quality management is a new management strategy in which thinning prescriptions are based solely on tree quality rather than a quantitative level of residual stand density. As long as residual density falls within fairly broad limits, prescriptions are based on tree quality alone. We applied four thinning prescriptions based on stand quality management, along...

  18. Stand development and yields of Appalachian hardwood stands managed with single-tree selection for at least 30 years

    Science.gov (United States)

    Neil I Lamson; H. Clay Smith; H. Clay Smith

    1991-01-01

    Appalachian hardwood stands in West Virginia were managed for 30 or more years using single-tree selection regeneration practices. Stand yield data suggest that current stand growth will provide economical harvest cuts for several future cutting cycles. This case study indicates that the single-tree selection practice has potential for landowners who want to maintain...

  19. The analysis of the accuracy of the wheel alignment inspection method on the side-slip plate stand

    Science.gov (United States)

    Gajek, A.; Strzępek, P.

    2016-09-01

    The article presents the theoretical basis and the results of the examination of the wheel alignment inspection method on the slide slip plate stand. It is obligatory test during periodic technical inspection of the vehicle. The measurement is executed in the dynamic conditions. The dependence between the lateral displacement of the plate and toe-in of the tested wheels has been shown. If the diameter of the wheel rim is known then the value of the toe-in can be calculated. The comparison of the toe-in measurements on the plate stand and on the four heads device for the wheel alignment inspection has been carried out. The accuracy of the measurements and the influence of the conditions of the tests on the plate stand (the way of passing through the plate) were estimated. The conclusions about the accuracy of this method are presented.

  20. Prediction and Cross-Situational Consistency of Daily Behavior across Cultures: Testing Trait and Cultural Psychology Perspectives

    Science.gov (United States)

    Church, A. Timothy; Katigbak, Marcia S.; Reyes, Jose Alberto S.; Salanga, Maria Guadalupe C.; Miramontes, Lilia A.; Adams, Nerissa B.

    2008-01-01

    Trait and cultural psychology perspectives on the cross-situational consistency of behavior, and the predictive validity of traits, were tested in a daily process study in the United States (N = 68), an individualistic culture, and the Philippines (N = 80), a collectivistic culture. Participants completed the Revised NEO Personality Inventory (Costa & McCrae, 1992) and a measure of self-monitoring, then reported their daily behaviors and associated situational contexts for approximately 30 days. Consistent with trait perspectives, the Big Five traits predicted daily behaviors in both cultures, and relative (interindividual) consistency was observed across many, although not all, situational contexts. The frequency of various Big Five behaviors varied across relevant situational contexts in both cultures and, consistent with cultural psychology perspectives, there was a tendency for Filipinos to exhibit greater situational variability than Americans. Self-monitoring showed some ability to account for individual differences in situational variability in the American sample, but not the Filipino sample. PMID:22146866

  1. Minimum joint space width (mJSW) of patellofemoral joint on standing ''skyline'' radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

    International Nuclear Information System (INIS)

    Simoni, Paolo; Jamali, Sanaa; Alvarez Miezentseva, Victoria; Albert, Adelin; Totterman, Saara; Schreyer, Edward; Tamez-Pena, Jose G.; Zobel, Bruno Beomonte; Gillet, Philippe

    2013-01-01

    To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing ''skyline'' radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). A couple of standing ''skyline'' radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 ± 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Standing ''skyline'' radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements. (orig.)

  2. Reliability of standing weight-bearing (0.25T) MR imaging findings and positional changes in the lumbar spine

    DEFF Research Database (Denmark)

    Hansen, Bjarke B; Hansen, Philip; Christensen, Anders F

    2018-01-01

    OBJECTIVE: To test the reliability and absolute agreement of common degenerative findings in standing positional magnetic resonance imaging (pMRI). METHODS AND MATERIALS: Low back pain patients with and without sciatica were consecutively enrolled to undergo a supine and standing pMRI. Three...

  3. Evaluating the Consistency of the FNA Test in Pathologically Proven Nodules of Thyroidectomy

    Directory of Open Access Journals (Sweden)

    Alireza Khazaei

    2018-02-01

    Full Text Available Fine Needle Aspiration (FNA is a selective diagnostic technique for the evaluation of non-toxic thyroid nodules. Thyroid FNA results are either undiagnosed or suspicious and indeterminate in 20-30% of cases. Therefore, this study seeks to determine the consistency of the FNA test in pathologically proven nodules of thyroidectomy. This is a descriptive cross-sectional study carried out on a total of 73 candidates for thyroidectomy who had been admitted to Imam Ali Hospital. A census sampling method has been used in this study. The FNA samples and pathology samples were evaluated and the consistency of the FNA test in pathologically proven nodules were compared. The SPSS software was used for data analysis. The mean age of the patients was 40.1 ± 12.9 years. 23.3% of the participants were male and 76.7% of them were female. The malignancy rate in the pathology was 65.8% (48 cases and 53.4% (39 cases in the FNA. Of the 48 positive cases, the FNA pathology diagnosed 35 cases (72.9% as positive and 13 cases (27.1% as negative. Of the 25 negative cases, the FNA pathology diagnosed 21 cases (84% as negative and 4 cases (16% as positive. Sensitivity, specificity, positive and negative predictive values of FNA in malignancy diagnosis were 72.92, 84, 89.74, and 61.76%, respectively. The results show that FNA does not have a high sensitivity in the diagnosis of malignancy, but has good specificity and the use of other diagnostic methods before the operation of thyroid nodules seems necessary.

  4. Mixing Effects in Norway Spruce—European Beech Stands Are Modulated by Site Quality, Stand Age and Moisture Availability

    Directory of Open Access Journals (Sweden)

    Léa Houpert

    2018-02-01

    Full Text Available Although mixing tree species is considered an efficient risk-reduction strategy in the face of climate change, the conditions where mixtures are more productive than monocultures are under ongoing debate. Generalizations have been difficult because of the variety of methods used and due to contradictory findings regarding the effects of the species investigated, mixing proportions, and many site and stand conditions. Using data from 960 plots of the Swiss National Forest Inventory data, we assessed whether Picea abies (L. Karst–Fagus sylvatica L. mixed stands are more productive than pure stands, and whether the mixing effect depends on site- or stand-characteristics. The species proportions were estimated using species proportion by area, which depends on the maximum stand basal area of an unmanaged stand (BAmax. Four different alternatives were used to estimate BAmax and to investigate the effect of these differing alternatives on the estimated mixture effect. On average, the mixture had a negative effect on the growth of Picea abies. However, this effect decreased as moisture availability increased. Fagus sylvatica grew better in mixtures and this effect increased with site quality. A significant interaction between species proportions and quadratic mean diameter, a proxy for stand age, was found for both species: the older the stand, the better the growth of Fagus sylvatica and the lower the growth of Picea abies. Overyielding was predicted for 80% of the investigated sites. The alternative to estimate BAmax weakly modulated the estimated mixture effect, but it did not affect the way mixing effects changed with site characteristics.

  5. Stand-structural effects on Heterobasidion abietinum-related mortality following drought events in Abies pinsapo.

    Science.gov (United States)

    Linares, Juan Carlos; Camarero, Jesús Julio; Bowker, Matthew A; Ochoa, Victoria; Carreira, José Antonio

    2010-12-01

    Climate change may affect tree-pathogen interactions. This possibility has important implications for drought-prone forests, where stand dynamics and disease pathogenicity are especially sensitive to climatic stress. In addition, stand structural attributes including density-dependent tree-to-tree competition may modulate the stands' resistance to drought events and pathogen outbreaks. To assess the effects of stand structure on root-rot-related mortality after severe droughts, we focused on Heterobasidion abietinum mortality in relict Spanish stands of Abies pinsapo, a drought-sensitive fir. We compared stand attributes and tree spatial patterns in three plots with H. abietinum root-rot disease and three plots without root-rot. Point-pattern analyses were used to investigate the scale and extent of mortality patterns and to test hypotheses related to the spread of the disease. Dendrochronology was used to date the year of death and to assess the association between droughts and growth decline. We applied a structural equation modelling approach to test if tree mortality occurs more rapidly than predicted by a simple distance model when trees are subjected to high tree-to-tree competition and following drought events. Contrary to expectations of drought mortality, the effect of precipitation on the year of death was strong and negative, indicating that a period of high precipitation induced an earlier tree death. Competition intensity, related to the size and density of neighbour trees, also induced an earlier tree death. The effect of distance to the disease focus was negligible except in combination with intensive competition. Our results indicate that infected trees have decreased ability to withstand drought stress, and demonstrate that tree-to-tree competition and fungal infection act as predisposing factors of forest decline and mortality.

  6. The effect of different unstable footwear constructions on centre of pressure motion during standing.

    Science.gov (United States)

    Plom, W; Strike, S C; Taylor, M J D

    2014-06-01

    The aim of this study was to test the effect different unstable footwear constructions have on centre of pressure motion when standing. Sixteen young female volunteers were tested in five conditions, three unstable footwear (Reebok Easy-Tone, FitFlop and Skechers Shape-Ups), a standard shoe and barefoot in a randomised order. Double and single leg balance on a force plate was assessed via centre of pressure excursions and displacements in each condition. For double leg and single leg standing centre of pressure excursions in the anterior-posterior direction were significantly increased wearing Skechers Shape-Ups compared to barefoot and the standard shoe. For the Reebok Easy Tone during single leg standing excursions in the anterior-posterior direction were significantly greater compared to the barefoot condition. Cumulative displacement of the centre of pressure in medial-lateral direction increased significantly during single leg standing when wearing Skechers Shape-Ups compared to barefoot and standard shoe as well as for Reebok Easy Tone vs. barefoot. It would appear from these quiet standing results that the manner of the construction of instability shoes effects the CoP movement which is associated with induced instability. Greater CoP excursion occurred in the A-P direction while the cumulative displacements were greater in the M-L direction for those shoes with the rounded sole and soft foam and those with airpods. The shoe construction with altered density foam did not induce any change in the CoP movement, during quite standing, which tends to suggest that it is not effective at inducing balance. Not all instability shoes are effective in altering the overall instability of the wearer. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Is the 1-minute sit-to-stand test a good tool for the evaluation of the impact of pulmonary rehabilitation? Determination of the minimal important difference in COPD

    Directory of Open Access Journals (Sweden)

    Vaidya T

    2016-10-01

    correlated with the change in QMVC (r=0.572; P=0.004 and 6MWD (r=0.428; P=0.006. Using the distribution-based analysis, an MID of 1.9 (standard error of measurement method or 3.1 (standard deviation method was found. With the 6MWD as anchor, the receiver operating characteristic curve identified the MID for the change in 1-minute STS repetitions at 2.5 (sensibility: 80%, specificity: 60% with area under curve of 0.716.Conclusion: The 1-minute STS test is simple and sensitive to measure the efficiency of PR. An improvement of at least three repetitions is consistent with physical benefits after PR. Keywords: sit-to-stand test, COPD, 6-minute walk test, exercise tolerance, pulmonary rehabilitation

  8. Progress of the Hard-wired Instrumentation and Control Works for the Neutral Beam Test Stand at KAERI

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ki Sok

    2005-12-15

    Progress of the hard-wired instrumentation and control works for the neutral beam test stand(NB-TS) has been existed for the past one year period. Details of the installed arc detector circuit are explained. LN{sub 2} level and temperature control during the cryosorption pumping operation are explained with an emphasis on its control circuit. With an expectation of more accurate and sensitive measurement of temperatures than the thermocouple utilization during the calorimeter operation, PT-100 resistance temperature detector(RTD) utilization is initiated and the results are described. During the ion beam experiment, physical measurements are made with some delayed time than the beam extraction, and thus a delayed trigger pulse generator was fabricated and installed to the system. Underlying principles of the electronic circuits for the interlock implementation and optical signal transmission are introduced. These are basically the application of operational amplifier circuits. A cautious aspect of the SMPS(switch mode power supply) utilization is also give.

  9. Progress of the Hard-wired Instrumentation and Control Works for the Neutral Beam Test Stand at KAERI

    International Nuclear Information System (INIS)

    Jung, Ki Sok

    2005-12-01

    Progress of the hard-wired instrumentation and control works for the neutral beam test stand(NB-TS) has been existed for the past one year period. Details of the installed arc detector circuit are explained. LN 2 level and temperature control during the cryosorption pumping operation are explained with an emphasis on its control circuit. With an expectation of more accurate and sensitive measurement of temperatures than the thermocouple utilization during the calorimeter operation, PT-100 resistance temperature detector(RTD) utilization is initiated and the results are described. During the ion beam experiment, physical measurements are made with some delayed time than the beam extraction, and thus a delayed trigger pulse generator was fabricated and installed to the system. Underlying principles of the electronic circuits for the interlock implementation and optical signal transmission are introduced. These are basically the application of operational amplifier circuits. A cautious aspect of the SMPS(switch mode power supply) utilization is also give

  10. 300 GHz Imaging System with 8 Meter Stand-off Distance and One-Dimensional Synthetic Image Reconstruction for Remote Detection of Material Defects

    DEFF Research Database (Denmark)

    Keil, Andreas; Peuser, Jörn; Loeffler, Torsten

    2011-01-01

    An active stand-off imaging system operating at 230–320 GHz is presented. Imaging is achieved by combining a line array consisting of 8 sources and 16 detectors with a scanning cylindrical mirror system. The stand-off distance is 8 meters and the effective aperture of the system is 0.5 meters by ...

  11. A Development of Force Plate for Biomechanics Analysis of Standing and Walking

    Science.gov (United States)

    Wardoyo, S.; Hutajulu, P. T.; Togibasa, O.

    2016-08-01

    Force plates are known as an excellent teaching aid to demonstrate the kinematics and dynamics of motion and commonly used in biomechanics laboratories to measure ground forces involved in the motion of human. It is consist of a metal plate with sensors attached to give an electrical output proportional to the force on the plate. Moreover, force plates are useful for examining the kinetic characteristics of an athlete's movement. They provide information about the external forces involved in movement that can aid a coach or sports scientist to quantitatively evaluate the athlete's skill development. In this study, we develop our prototype of force plate with less than 100,- simply by using flexible force transducer attached inside rubber matt, in the form of square blocks (dimension: 250 mm × 150 mm × 10 mm), with maximum load up to 60 kg. The handmade force plate was tested by applying biomechanics analysis for standing and walking. The testing was done on Experimental Soccer Courses’ students at the Department of Physical Education, Health and Recreation, University of Cenderawasih. The design of the force plate system together with biomechanics analysis will be discussed.

  12. 21 CFR 880.2700 - Stand-on patient scale.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stand-on patient scale. 880.2700 Section 880.2700... Devices § 880.2700 Stand-on patient scale. (a) Identification. A stand-on patient scale is a device intended for medical purposes that is used to weigh a patient who is able to stand on the scale platform...

  13. Advance reproduction and other stand characteristics in Pennsylvania and French stands of northern red oak

    Science.gov (United States)

    Kim C. Steiner; Marc D. Abrams; Todd W. Bowersox

    1993-01-01

    The frequent scarcity of northern red oak (NRO) advance reproduction raises questions about its regeneration potential under prevailing stand conditions in eastern North America. In contrast, NRO plantations in France typically contain abundant advance reproduction. The purpose of this study was to document stand conditions in Pennsylvania (PA) and southwestern France...

  14. Heat driven thermoacoustic cooler based on traveling-standing wave

    International Nuclear Information System (INIS)

    Kang Huifang; Zhou Gang; Li Qing

    2010-01-01

    This paper presents a heat driven thermoacoustic cooler system without any moving part. It consists of a thermoacoustic engine and a thermoacoustic cooler, and the former is the driving source of the latter. Both the engine and the cooler are located in one loop tube coupled with a resonator tube, and the acoustic power produced by the engine is used to drive the cooler directly. Both regenerators of the engine and the cooler are located in the near region of the pressure antinode, and operate in traveling-standing wave phase region. In the engine's regenerator, both components of the standing wave and the traveling wave realize the conversion from heat to acoustic energy. This improves the efficiency of the engine. In the cooler's regenerator, both components of the traveling wave and the standing wave pump heat from the cold end. This improves the efficiency of the cooler. At the operating point with a mean pressure of 22 bar, helium as working gas, a frequency of 234 Hz, and a heating power of 300 W, the experimental cooler provides a no-load temperature of -30 deg. C and a cooling power of 40 W at the cooling temperature of 0 deg. C. The total length of this cooler system is less than 1 m, which shows a good prospect for the domestic cooler system in room-temperature cooling such as food refrigeration and air-conditioning.

  15. Robot-supported assessment of balance in standing and walking.

    Science.gov (United States)

    Shirota, Camila; van Asseldonk, Edwin; Matjačić, Zlatko; Vallery, Heike; Barralon, Pierre; Maggioni, Serena; Buurke, Jaap H; Veneman, Jan F

    2017-08-14

    Clinically useful and efficient assessment of balance during standing and walking is especially challenging in patients with neurological disorders. However, rehabilitation robots could facilitate assessment procedures and improve their clinical value. We present a short overview of balance assessment in clinical practice and in posturography. Based on this overview, we evaluate the potential use of robotic tools for such assessment. The novelty and assumed main benefits of using robots for assessment are their ability to assess 'severely affected' patients by providing assistance-as-needed, as well as to provide consistent perturbations during standing and walking while measuring the patient's reactions. We provide a classification of robotic devices on three aspects relevant to their potential application for balance assessment: 1) how the device interacts with the body, 2) in what sense the device is mobile, and 3) on what surface the person stands or walks when using the device. As examples, nine types of robotic devices are described, classified and evaluated for their suitability for balance assessment. Two example cases of robotic assessments based on perturbations during walking are presented. We conclude that robotic devices are promising and can become useful and relevant tools for assessment of balance in patients with neurological disorders, both in research and in clinical use. Robotic assessment holds the promise to provide increasingly detailed assessment that allows to individually tailor rehabilitation training, which may eventually improve training effectiveness.

  16. Characterization and Performance Testing of Natural Gas Compressors for Residential and Commercial Applications

    Science.gov (United States)

    Zhang, Xinye; Groll, Eckhard A.; Bethel, Dylan

    2017-08-01

    Relatively little information is available in the literature with respect to the performance of compressors used during the dynamic charging process of a tank. Therefore, work presented in this paper shows the measurement results of performance testing of a natural gas compressor and analyses the compressor characterization based on the experimental data. Initial tests were conducted using air and carbon dioxide given the thermodynamic similarities between these fluids and natural gas. Finally, a new test stand was specifically designed and built for compressor dynamic testing using pipeline natural gas (NG) and the compressor reliability has been evaluated inside an explosion-proof engine test cell. Reliability tests at standard operating conditions monitored the performance consistency of the compressors over the testing period and the testing consisted of a series of tank charges aimed at evaluating the maximum operating temperature as well as the mass flow rate in the system.

  17. Economic considerations of managing stands

    Science.gov (United States)

    Gary W. Miller

    1989-01-01

    Managing central hardwood stands involves making choices. Each year landowners face at least three alternatives for managing a stand: (1) allow it to grow undisturbed, (2) undertake a partial or complete commercial harvest, or (3) culture the timber crop through a precommercial investment. Each activity affects long-term monetary returns. The "best" choice in...

  18. Control Performance of General Electric Fuel and Torque Regulator Operating on T31-3 Turbine-Propeller Engine in Sea-Level Test Stand

    Science.gov (United States)

    Oppenheimer, Frank L.; Lazar, James

    1951-01-01

    A .General Electric fuel and torque regulator was tested in conjunction with a T31-3 turbine-propeller engine in the sea-level static test stand at the NACA Lewis laboratory. The engine and control were operated over the entire speed range: 11,000 rpm, nominal flight idle, to 13,000 rpm, full power. Steady-state and transient data were recorded and are presented with a description of the four control loops being used in the system. Results of this investigation indicated that single-lever control operation was satisfactory under conditions of test. Transient data presented showed that turbine-outlet temperature did overshoot maximum operating value on acceleration but that the time duration of overshoot did not exceed approximately 1 second. This temperature limiting resulted from a control on fuel flow as a function of engine speed. Speed and torque first reached their desired values 0.4 second from the time of change in power-setting lever position. Maximum speed overshoot was 3 percent.

  19. Associations of knee extensor strength and standing balance with physical function in knee osteoarthritis.

    Science.gov (United States)

    Pua, Yong-Hao; Liang, Zhiqi; Ong, Peck-Hoon; Bryant, Adam L; Lo, Ngai-Nung; Clark, Ross A

    2011-12-01

    Knee extensor strength is an important correlate of physical function in patients with knee osteoarthritis; however, it remains unclear whether standing balance is also a correlate. The purpose of this study was to evaluate the cross-sectional associations of knee extensor strength, standing balance, and their interaction with physical function. One hundred four older adults with end-stage knee osteoarthritis awaiting a total knee replacement (mean ± SD age 67 ± 8 years) participated. Isometric knee extensor strength was measured using an isokinetic dynamometer. Standing balance performance was measured by the center of pressure displacement during quiet standing on a balance board. Physical function was measured by the self-report Short Form 36 (SF-36) questionnaire and by the 10-meter fast-pace gait speed test. After adjustment for demographic and knee pain variables, we detected significant knee strength by standing balance interaction terms for both SF-36 physical function and fast-pace gait speed. Interrogation of the interaction revealed that standing balance in the anteroposterior plane was positively related to physical function among patients with lower knee extensor strength. Conversely, among patients with higher knee extensor strength, the standing balance-physical function associations were, or tended to be, negative. These findings suggest that although standing balance was related to physical function in patients with knee osteoarthritis, this relationship was complex and dependent on knee extensor strength level. These results are of importance in developing intervention strategies and refining theoretical models, but they call for further study. Copyright © 2011 by the American College of Rheumatology.

  20. Thermodynamic consistency test procedure using orthogonal collocation and the Peng-Robinson equation of state

    International Nuclear Information System (INIS)

    Hamm, L.L.; Van Brunt, V.

    1982-08-01

    The Christiansen and Fredenslund programs for calculating vapor-liquid equilibria have been modified by replacing the Soave-Redlich-Kwong equation of state with the newly developed Peng-Robinson equation of state. This modification was shown to be a decided improvement for high pressure systems, especially in the critical and upper retrograde regions. Thermodynamic consistency tests were developed and used to evaluate and compare calculated values from both the modified and unmodified programs with reported experimental data for several vapor-liquid systems

  1. Product consistency testing of three reference glasses in stainless steel and perfluoroalkoxy resin vessels

    International Nuclear Information System (INIS)

    Olson, K.M.; Smith, G.L.; Marschman, S.C.

    1995-03-01

    Because of their chemical durability, silicate glasses have been proposed and researched since the mid-1950s as a medium for incorporating high-level radioactive waste (HLW) generated from processing of nuclear materials. A number of different waste forms were evaluated and ranked in the early 1980s; durability (leach resistance) was the highest weighted factor. Borosilicate glass was rated the best waste form available for incorporation of HLW. Four different types of vessels and three different glasses were used to study the possible effect of vessel composition on durability test results from the Production Consistency Test (PCT). The vessels were 45-m 304 stainless steel vessels, 150-m 304 L stainless steel vessels, and 60-m perfluoroalkoxy (PFA) fluoropolymer resin vessels. The three glasses were the Environmental Assessment glass manufactured by Corning Incorporated and supplied by Westinghouse Savannah River company, and West Valley Nuclear Services reference glasses 5 and 6, manufactured and supplied by Catholic University of America. Within experimental error, no differences were found in durability test results using the 3 different glasses in the 304L stainless steel or PFA fluoropolymer resin vessels over the seven-day test period

  2. On Consistency Test Method of Expert Opinion in Ecological Security Assessment.

    Science.gov (United States)

    Gong, Zaiwu; Wang, Lihong

    2017-09-04

    To reflect the initiative design and initiative of human security management and safety warning, ecological safety assessment is of great value. In the comprehensive evaluation of regional ecological security with the participation of experts, the expert's individual judgment level, ability and the consistency of the expert's overall opinion will have a very important influence on the evaluation result. This paper studies the consistency measure and consensus measure based on the multiplicative and additive consistency property of fuzzy preference relation (FPR). We firstly propose the optimization methods to obtain the optimal multiplicative consistent and additively consistent FPRs of individual and group judgments, respectively. Then, we put forward a consistency measure by computing the distance between the original individual judgment and the optimal individual estimation, along with a consensus measure by computing the distance between the original collective judgment and the optimal collective estimation. In the end, we make a case study on ecological security for five cities. Result shows that the optimal FPRs are helpful in measuring the consistency degree of individual judgment and the consensus degree of collective judgment.

  3. Chemical Composition Analysis and Product Consistency Tests of the ORP Phase 5 Nepheline Study Glasses

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Caldwell, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Riley, W. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2018-02-01

    In this report, the Savannah River National Laboratory (SRNL) provides chemical analyses and Product Consistency Test (PCT) results for a series of simulated high-level waste glass compositions fabricated by the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved models for the prediction of nepheline crystallization in support of the Hanford Tank Waste Treatment and Immobilization Plant (WTP).

  4. Dynamics of Connecticut hemlock stands

    Science.gov (United States)

    Jeffrey S. Ward; David M. Smith

    2000-01-01

    The stand dynamics and production of two one-acre plots of eastern hemlock (Tsuga canadensis L) in Connecticut have been followed for more than six decades. Data were recorded for all individual trees. One plot (Saltonstall) was established in 1924 after the removal of a hardwood overstory. This stand had a nearly pure, almost fully closed understory...

  5. Sapflow-Based Stand Transpiration in a Semiarid Natural Oak Forest on China’s Loess Plateau

    Directory of Open Access Journals (Sweden)

    Mei-Jie Yan

    2016-10-01

    Full Text Available The semi-arid region of China’s Loess Plateau is characterized by fragile ecosystems and a shortage of water resources. The major natural forest type in this region is the secondary forest with the flora dominated by the Liaodong oak (Quercus liaotungensis Koidz.. To understand its transpiration water use in relation to environmental factors, we applied Granier-type thermal dissipation probes to monitor stem sap flows of 21 sample trees, representing different classes of diameter at breast height in a permanent plot. The stem- and stand-scale transpiration values during the 2008–2010 growing seasons were estimated using measurements of sap flux densities and corresponding sapwood areas. The dominant factors affecting stand-scale transpiration varied with time scales. Daily stand transpiration correlated with daily solar radiation and daytime average vapor pressure deficit. Seasonal and interannual changes in stand transpiration were closely related to leaf area index (LAI values. No obvious relationship was observed between monthly stand transpiration and soil moisture or precipitation during the period, probably as a result of both the hysteretic effect of precipitation on transpiration, and changes in LAI throughout the growing season. Stand transpiration during the three growing seasons ranged from 75 to 106 mm, representing low to normal values for the semi-arid forest. The proportion of transpiration by oak trees in the stand was stable ranging from 60% to 66% and corresponded to their basal area proportion of approximately 59%. The results suggest that the natural forest consisting mainly of oak trees is in a formal stage of forest development that maintains a normal magnitude of annual water consumption.

  6. Static trunk posture in sitting and standing during pregnancy and early postpartum.

    Science.gov (United States)

    Gilleard, Wendy L; Crosbie, Jack; Smith, Richard

    2002-12-01

    To investigate the postural alignment of the upper body in the sagittal plane during sitting and standing postures as pregnancy progressed and then in the postpartum period. Longitudinal, repeated-measures design. Biomechanics laboratory in an Australian university. A volunteer convenience sample of 9 primiparous and multiparous women and 12 nulliparous women serving as a control group. Not applicable. Subjects were filmed while sitting and during quiet standing at intervals throughout pregnancy and at 8 weeks postpartum. A repeated-measures analysis of variance was used to assess systematic changes in the alignment of the pelvic, thoracic, and head segments, and the thoracolumbar and cervicothoracic spines. Student t tests were used to compare the postpartum and nulliparous control groups. There was no significant effect of pregnancy on the upper-body posture, although there was a tendency in some subjects for a flatter thoracolumbar spinal curve in sitting as pregnancy progressed. Postpartum during standing, the pelvic segment had a reduced sagittal plane anterior orientation, and the thoracolumbar spine was less extended, indicating a flatter spinal curve compared with the control group. There was no significant effect of pregnancy on upper-body posture during sitting and standing, although individuals varied in their postural response. A flatter spinal curve was found during standing postpartum. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation

  7. Upgrade of the Cryogenic CERN RF Test Facility

    CERN Document Server

    Pirotte, O; Brunner, O; Inglese, V; Koettig, T; Maesen, P; Vullierme, B

    2014-01-01

    With the large number of superconducting radiofrequency (RF) cryomodules to be tested for the former LEP and the present LHC accelerator a RF test facility was erected early in the 1990’s in the largest cryogenic test facility at CERN located at Point 18. This facility consisted of four vertical test stands for single cavities and originally one and then two horizontal test benches for RF cryomodules operating at 4.5 K in saturated helium. CERN is presently working on the upgrade of its accelerator infrastructure, which requires new superconducting cavities operating below 2 K in saturated superfluid helium. Consequently, the RF test facility has been renewed in order to allow efficient cavity and cryomodule tests in superfluid helium and to improve its thermal performances. The new RF test facility is described and its performances are presented.

  8. Upgrade of the cryogenic CERN RF test facility

    International Nuclear Information System (INIS)

    Pirotte, O.; Benda, V.; Brunner, O.; Inglese, V.; Maesen, P.; Vullierme, B.; Koettig, T.

    2014-01-01

    With the large number of superconducting radiofrequency (RF) cryomodules to be tested for the former LEP and the present LHC accelerator a RF test facility was erected early in the 1990’s in the largest cryogenic test facility at CERN located at Point 18. This facility consisted of four vertical test stands for single cavities and originally one and then two horizontal test benches for RF cryomodules operating at 4.5 K in saturated helium. CERN is presently working on the upgrade of its accelerator infrastructure, which requires new superconducting cavities operating below 2 K in saturated superfluid helium. Consequently, the RF test facility has been renewed in order to allow efficient cavity and cryomodule tests in superfluid helium and to improve its thermal performances. The new RF test facility is described and its performances are presented

  9. Expanding the Reach of Participatory Risk Management: Testing an Online Decision-Aiding Framework for Informing Internally Consistent Choices.

    Science.gov (United States)

    Bessette, Douglas L; Campbell-Arvai, Victoria; Arvai, Joseph

    2016-05-01

    This article presents research aimed at developing and testing an online, multistakeholder decision-aiding framework for informing multiattribute risk management choices associated with energy development and climate change. The framework was designed to provide necessary background information and facilitate internally consistent choices, or choices that are in line with users' prioritized objectives. In order to test different components of the decision-aiding framework, a six-part, 2 × 2 × 2 factorial experiment was conducted, yielding eight treatment scenarios. The three factors included: (1) whether or not users could construct their own alternatives; (2) the level of detail regarding the composition of alternatives users would evaluate; and (3) the way in which a final choice between users' own constructed (or highest-ranked) portfolio and an internally consistent portfolio was presented. Participants' self-reports revealed the framework was easy to use and providing an opportunity to develop one's own risk-management alternatives (Factor 1) led to the highest knowledge gains. Empirical measures showed the internal consistency of users' decisions across all treatments to be lower than expected and confirmed that providing information about alternatives' composition (Factor 2) resulted in the least internally consistent choices. At the same time, those users who did not develop their own alternatives and were not shown detailed information about the composition of alternatives believed their choices to be the most internally consistent. These results raise concerns about how the amount of information provided and the ability to construct alternatives may inversely affect users' real and perceived internal consistency. © 2015 Society for Risk Analysis.

  10. Future directions in standing-wave photoemission

    International Nuclear Information System (INIS)

    Gray, Alexander X.

    2014-01-01

    Highlights: • Probing magnetic properties at the buried interface with SW-MCD. • Probing electronic structure at the buried interface with resonant SW-XPS and SW-HAXPES. • Probing momentum-resolved electronic structure at a buried interface with SWARPES. • Adding depth resolution to photoemission microscopy with standing-wave excitation. • Standing-wave localization, total reflection and waveguide effects. - Abstract: Over the past decade, standing-wave photoemission (SW-XPS) has evolved into a powerful and versatile non-destructive technique for probing element-specific electronic, magnetic, and structural properties of buried layers and interfaces with sub-nanometer depth resolution. In this article, I will discuss several promising future directions in this emergent field stemming from experimental and theoretical studies wherein SW-XPS is combined with other X-ray techniques, such as magnetic circular dichroism (MCD), hard X-ray photoemission spectroscopy (HAXPES), angle-resolved photoemission (ARPES), and photoemission microscopy (PEEM), adding extra dimensions to the measurement and thus widening the scope of scientific and technological questions accessible via the use of standing waves. I will further discuss examples of recently developed methods for X-ray standing-wave data analysis, which yield layer-resolved matrix-element-weighted densities of states at interfaces as well as Ångstrom-level changes in periodicity of synthetic superlattices. Finally, I will explore the possibility of localizing the standing waves near the surface and within a buried layer by the use of aperiodic superlattices, total reflection, and X-ray waveguide effects

  11. Future directions in standing-wave photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Alexander X., E-mail: axgray@temple.edu

    2014-08-15

    Highlights: • Probing magnetic properties at the buried interface with SW-MCD. • Probing electronic structure at the buried interface with resonant SW-XPS and SW-HAXPES. • Probing momentum-resolved electronic structure at a buried interface with SWARPES. • Adding depth resolution to photoemission microscopy with standing-wave excitation. • Standing-wave localization, total reflection and waveguide effects. - Abstract: Over the past decade, standing-wave photoemission (SW-XPS) has evolved into a powerful and versatile non-destructive technique for probing element-specific electronic, magnetic, and structural properties of buried layers and interfaces with sub-nanometer depth resolution. In this article, I will discuss several promising future directions in this emergent field stemming from experimental and theoretical studies wherein SW-XPS is combined with other X-ray techniques, such as magnetic circular dichroism (MCD), hard X-ray photoemission spectroscopy (HAXPES), angle-resolved photoemission (ARPES), and photoemission microscopy (PEEM), adding extra dimensions to the measurement and thus widening the scope of scientific and technological questions accessible via the use of standing waves. I will further discuss examples of recently developed methods for X-ray standing-wave data analysis, which yield layer-resolved matrix-element-weighted densities of states at interfaces as well as Ångstrom-level changes in periodicity of synthetic superlattices. Finally, I will explore the possibility of localizing the standing waves near the surface and within a buried layer by the use of aperiodic superlattices, total reflection, and X-ray waveguide effects.

  12. Edaphic, salinity, and stand structural trends in chronosequences of native and non-native dominated riparian forests along the Colorado River, USA

    Science.gov (United States)

    Merritt, David M.; Shafroth, Patrick B.

    2012-01-01

    Tamarix spp. are introduced shrubs that have become among the most abundant woody plants growing along western North American rivers. We sought to empirically test the long-held belief that Tamarix actively displaces native species through elevating soil salinity via salt exudation. We measured chemical and physical attributes of soils (e.g., salinity, major cations and anions, texture), litter cover and depth, and stand structure along chronosequences dominated by Tamarix and those dominated by native riparian species (Populus or Salix) along the upper and lower Colorado River in Colorado and Arizona/California, USA. We tested four hypotheses: (1) the rate of salt accumulation in soils is faster in Tamarix-dominated stands than stands dominated by native species, (2) the concentration of salts in the soil is higher in mature stands dominated by Tamarix compared to native stands, (3) soil salinity is a function of Tamarix abundance, and (4) available nutrients are more concentrated in native-dominated stands compared to Tamarix-dominated stands. We found that salt concentration increases at a faster rate in Tamarix-dominated stands along the relatively free-flowing upper Colorado but not along the heavily-regulated lower Colorado. Concentrations of ions that are known to be preferentially exuded by Tamarix (e.g., B, Na, and Cl) were higher in Tamarix stands than in native stands. Soil salt concentrations in older Tamarix stands along the upper Colorado were sufficiently high to inhibit germination, establishment, or growth of some native species. On the lower Colorado, salinity was very high in all stands and is likely due to factors associated with floodplain development and the hydrologic effects of river regulation, such as reduced overbank flooding, evaporation of shallow ground water, higher salt concentrations in surface and ground water due to agricultural practices, and higher salt concentrations in fine-textured sediments derived from naturally saline

  13. Frontal Plane Modelling of Human Dynamics during Standing in Narrow-Stance

    Science.gov (United States)

    Sonobe, M.; Yamaguchi, H.; Hino, J.

    2016-09-01

    Standing ride type vehicles like electric skateboards have been developed in recent years. Although these vehicles have advantages as being compact and low cost due to their simple structure, it is necessary to improve the riding quality. Therefore, the system aiding riders to keep their balance on a skateboard by feedback control or feedforward control has been required. To achieve it, a human balance model should be built as simple as possible. In this study, we focus on the human balance modelling during standing when the support surface moves largely. We restricted the model on frontal plane and narrow stance because the restrictions allow us to assume single-degree-of-freedom model. The balance control system is generally assumed as a delayed feedback control system. The model was identified through impulse response test and frequency response test. As a result, we found the phase between acceleration of the skateboard and posture angle become opposite phase in low frequency range.

  14. Personality consistency in dogs: a meta-analysis.

    Science.gov (United States)

    Fratkin, Jamie L; Sinn, David L; Patall, Erika A; Gosling, Samuel D

    2013-01-01

    Personality, or consistent individual differences in behavior, is well established in studies of dogs. Such consistency implies predictability of behavior, but some recent research suggests that predictability cannot be assumed. In addition, anecdotally, many dog experts believe that 'puppy tests' measuring behavior during the first year of a dog's life are not accurate indicators of subsequent adult behavior. Personality consistency in dogs is an important aspect of human-dog relationships (e.g., when selecting dogs suitable for substance-detection work or placement in a family). Here we perform the first comprehensive meta-analysis of studies reporting estimates of temporal consistency of dog personality. A thorough literature search identified 31 studies suitable for inclusion in our meta-analysis. Overall, we found evidence to suggest substantial consistency (r = 0.43). Furthermore, personality consistency was higher in older dogs, when behavioral assessment intervals were shorter, and when the measurement tool was exactly the same in both assessments. In puppies, aggression and submissiveness were the most consistent dimensions, while responsiveness to training, fearfulness, and sociability were the least consistent dimensions. In adult dogs, there were no dimension-based differences in consistency. There was no difference in personality consistency in dogs tested first as puppies and later as adults (e.g., 'puppy tests') versus dogs tested first as puppies and later again as puppies. Finally, there were no differences in consistency between working versus non-working dogs, between behavioral codings versus behavioral ratings, and between aggregate versus single measures. Implications for theory, practice, and future research are discussed.

  15. Personality consistency in dogs: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Jamie L Fratkin

    Full Text Available Personality, or consistent individual differences in behavior, is well established in studies of dogs. Such consistency implies predictability of behavior, but some recent research suggests that predictability cannot be assumed. In addition, anecdotally, many dog experts believe that 'puppy tests' measuring behavior during the first year of a dog's life are not accurate indicators of subsequent adult behavior. Personality consistency in dogs is an important aspect of human-dog relationships (e.g., when selecting dogs suitable for substance-detection work or placement in a family. Here we perform the first comprehensive meta-analysis of studies reporting estimates of temporal consistency of dog personality. A thorough literature search identified 31 studies suitable for inclusion in our meta-analysis. Overall, we found evidence to suggest substantial consistency (r = 0.43. Furthermore, personality consistency was higher in older dogs, when behavioral assessment intervals were shorter, and when the measurement tool was exactly the same in both assessments. In puppies, aggression and submissiveness were the most consistent dimensions, while responsiveness to training, fearfulness, and sociability were the least consistent dimensions. In adult dogs, there were no dimension-based differences in consistency. There was no difference in personality consistency in dogs tested first as puppies and later as adults (e.g., 'puppy tests' versus dogs tested first as puppies and later again as puppies. Finally, there were no differences in consistency between working versus non-working dogs, between behavioral codings versus behavioral ratings, and between aggregate versus single measures. Implications for theory, practice, and future research are discussed.

  16. Spin-stand imaging of overwritten data and its comparison with magnetic force microscopy

    International Nuclear Information System (INIS)

    Mayergoyz, I. D.; Tse, C.; Krafft, C.; Gomez, R. D.

    2001-01-01

    A new technique of magnetic imaging on a spin-stand [Mayergoyz , J. Appl. Phys. 87, 6824 (2000)] is further developed and extensively tested. The results of successful imaging of digital patterns overwritten with misregistration ranging from 0.3 to 0.07 μm are reported. The results are compared with magnetic force microscopy (MFM) images and the conclusion is reached that the spin-stand imaging technique can provide (at least) the same level of resolution and accuracy as the MFM imaging technique. [copyright] 2001 American Institute of Physics

  17. Relationship of Tree Stand Heterogeneity and Forest Naturalness

    Directory of Open Access Journals (Sweden)

    BARTHA, Dénes

    2006-01-01

    Full Text Available The aim of our study was to investigate if compositional (tree species richness andstructural (vertical structure, age-structure, patterns of canopy closure heterogeneity of the canopylayer is related to individual naturalness criteria and to overall forest naturalness at the stand scale. Thenaturalness values of the assessed criteria (tree species composition, tree stand structure, speciescomposition and structure of shrub layer and forest floor vegetation, dead wood, effects of game, sitecharacteristics showed similar behaviour when groups of stands with different heterogeneity werecompared, regardless of the studied aspect of canopy heterogeneity. The greatest difference was foundfor criteria describing the canopy layer. Composition and structure of canopy layer, dead wood andtotal naturalness of the stand differed significantly among the stand groups showing consistentlyhigher values from homogeneous to the most heterogeneous group. Naturalness of the compositionand structure of the shrub layer is slightly but significantly higher in stands with heterogeneous canopylayer. Regarding other criteria, significant differences were found only between the homogeneous andthe most heterogeneous groups, while groups with intermediate level of heterogeneity did not differsignificantly from one extreme. However, the criterion describing effects of game got lowernaturalness values in more heterogeneous stands. Naturalness of site characteristics did not differsignificantly among the groups except for when stands were grouped based on pattern of canopyclosure. From the practical viewpoint it is shown that purposeful forestry operations affecting thecanopy layer cause changes in compositional and structural characteristics of other layers as well as inoverall stand scale forest naturalness.

  18. Converting partially-stocked aspen stands to fully-stocked stands in the Lake States: an economic analysis.

    Science.gov (United States)

    Jeffrey T. Olson; Allen L. Lundgren

    1978-01-01

    The 1968 Wisconsin Forest Survey showed large areas of aspen type that are not considered fully stocked. The economic feasibility of converting partially-stocked stands to full stocking is examined, and a rule presented for determining when a partially-stocked stand should be harvested to maximize its present value.

  19. Effect of information feedback on training standing up following stroke: a pilot feasibility study.

    Science.gov (United States)

    Stanton, Rosalyn; Ada, Louise; Dean, Catherine M; Preston, Elisabeth

    2016-12-01

    The ability to stand up is reduced following stroke. Traditional biofeedback is effective in improving the performance of lower limb activities. The aim of this study was to investigate the feasibility of and potential for information feedback from a simple inexpensive device to improve the ability to stand up from a chair in people following stroke. A single-group study with pre-post measures design was used. Twenty people with hemiplegic stroke in inpatient rehabilitation received 10 sessions over 2 weeks of information feedback about foot placement during training of standing up. Progression involved increasing repetitions, increasing difficulty and fading feedback. Feasibility was determined by adherence, time taken, acceptability and safety. Clinical outcomes were the time taken to stand up, quality and foot position measured using the 5-Times-Sit-To-Stand-Test and carryover into daily activities measured by covert observation. The study was feasible with 97% of sessions completed, taking 19 (SD 6) to 25 (SD 10) minutes. Participants understood (4.6/5), found useful (4.6/5), challenging (4.4/5) and would recommend (4.7/5) the training. The time to stand up 5 times decreased by 24 (95% CI -48 to -1) s, and the quality of standing improved by 1.0/10.0 (95% CI 0.2 to 1.8). Carryover of the correct foot placement occurred to real life, with the beginning foot position correct 2.1/3.0 (95% CI 1.6 to 2.6) and end foot position correct 1.8/3.0 (95% CI 1.2 to 2.4) occasions. The training is feasible and has the potential to improve the ability to stand up.

  20. Blood pressure associates with standing balance in elderly outpatients.

    Directory of Open Access Journals (Sweden)

    Jantsje H Pasma

    Full Text Available OBJECTIVES: Assessment of the association of blood pressure measurements in supine and standing position after a postural change, as a proxy for blood pressure regulation, with standing balance in a clinically relevant cohort of elderly, is of special interest as blood pressure may be important to identify patients at risk of having impaired standing balance in routine geriatric assessment. MATERIALS AND METHODS: In a cross-sectional cohort study, 197 community-dwelling elderly referred to a geriatric outpatient clinic of a middle-sized teaching hospital were included. Blood pressure was measured intermittently (n = 197 and continuously (subsample, n = 58 before and after a controlled postural change from supine to standing position. The ability to maintain standing balance was assessed during ten seconds of side-by-side, semi-tandem and tandem stance, with both eyes open and eyes closed. Self-reported impaired standing balance and history of falls were recorded by questionnaires. Logistic regression analyses were used to examine the association between blood pressure and 1 the ability to maintain standing balance; 2 self-reported impaired standing balance; and 3 history of falls, adjusted for age and sex. RESULTS: Blood pressure decrease after postural change, measured continuously, was associated with reduced ability to maintain standing balance in semi-tandem stance with eyes closed and with increased self-reported impaired standing balance and falls. Presence of orthostatic hypotension was associated with reduced ability to maintain standing balance in semi-tandem stance with eyes closed for both intermittent and continuous measurements and with increased self-reported impaired standing balance for continuous measurements. CONCLUSION: Continuous blood pressure measurements are of additional value to identify patients at risk of having impaired standing balance and may therefore be useful in routine geriatric care.

  1. Calf tissue liquid stowage and muscular and deep vein distension in orthostatic tests after a 90-day head down bed rest

    Science.gov (United States)

    Arbeille, P.A.; Kerbeci, P.; Audebert, P.; Capri, A.; Pascaud, L.

    2005-08-01

    The objectives were to assess the contribution of (1) the calf veins distension and(2) the tissue liquid stowage during standtest, to orthostatic intolerance "OI" after a head down bed rest (HDBR) of 90days. Method: The population consisted of a control group (Co-gr, n=9) and an exercise Fly wheel counter-measure group (CM-gr, n=9). Calf vein cross sectional area (CSA) and surrounding tissue liquid content (tissue image darkness) were assessed by echography during pre and post HDBR stand-tests. Results: From supine to standing (post HDBR), the Tibial and muscular vein CSA increased significantly in non tolerant subjects whereas in tolerant subjects the vein CSA did not change. Post HDBR the tissue image darkness (proportional to tissue liquid content) increased more from supine to standing in non tolerant than in tolerant subjects. No significant difference were found between Co and exercise CM groups. Conclusion: High calf vein CSA and tissue liquid content increase at post-HDBR stand-test were significantly correlated with occurrence of OI but not with CM.

  2. Numerical Investigation of Three-dimensional Instability of Standing Waves

    Science.gov (United States)

    Zhu, Qiang; Liu, Yuming; Yue, Dick K. P.

    2002-11-01

    We study the three-dimensional instability of finite-amplitude standing waves under the influence of gravity using the transition matrix method. For accurate calculation of the transition matrices, we apply an efficient high-order spectral element method for nonlinear wave dynamics in complex domain. We consider two types of standing waves: (a) plane standing waves; and (b) standing waves in a circular tank. For the former, in addition to the confirmation of the side-band-like instability, we find a new three-dimensional instability for arbitrary base standing waves. The dominant component of the unstable disturbance is an oblique standing wave, with an arbitrary angle relative to the base flow, whose frequency is approximately equal to that of the base standing wave. Based on direct simulations, we confirm such a three-dimensional instability and show the occurrence of the Fermi-Pasta-Ulam recurrence phenomenon during nonlinear evolution. For the latter, we find that beyond a threshold wave steepness, the standing wave with frequency Ω becomes unstable to a small three-dimensional disturbance, which contains two dominant standing-wave components with frequencies ω1 and ω_2, provided that 2Ω ω1 + ω_2. The threshold wave steepness is found to decrease/increase as the radial/azimuthal wavenumber of the base standing wave increases. We show that the instability of standing waves in rectangular and circular tanks is caused by third-order quartet resonances between base flow and disturbance.

  3. Use of the SSF equations in the Kojima-Moon-Ochi thermodynamic consistency test of isothermal vapour-liquid equilibrium data

    Directory of Open Access Journals (Sweden)

    SLOBODAN P. SERBANOVIC

    2000-12-01

    Full Text Available The Kojima-Moon-Ochi (KMO thermodynamic consistency test of vapour–liquid equilibrium (VLE measurements for 32 isothermal data sets of binary systems of various complexity was applied using two fitting equations: the Redlich-Kister equation and the Sum of Symmetrical Functions. It was shown that the enhanced reliability of the fitting of the experimental data can change the conclusions drawn on their thermodynamic consistency in those cases of VLE data sets that are estimated to be near the border of consistency.

  4. The Design and Construction Process of a Test Stand for Casting the Power Steering’S Housing with the Use of the Pdcpd Material

    Science.gov (United States)

    Sobek, M.; Baier, A.; Grabowski, Ł.

    2018-01-01

    The use of new technologies and materials in various industries is a natural process that is directly related to the very high rate of development of these technologies. Certain industries decide to much faster introduce new technologies and materials. One of such branches is the automotive industry, whose representatives are very energetically looking for both financial savings and savings resulting from the vehicles mass reduction. An economically justified approach to construction materials is leading the search for new solutions and materials. The use of a modern material such as the two-component PDCPD composite shows hitherto unknown possibilities of producing subassemblies of many different constructions. The possibility of using a modern composite material with parameters comparable to that of metals and significantly lighter, can be an excellent alternative in the selection of materials for many parts of motor vehicles. The potentiality of precise casting of tolerated surfaces will allow to reduce the operations related to machining process, which is an indispensable part of the production process of elements that are cast of metal. This article describes the process of designing and building a test stand for precise positioning of power steering gear components at the stage of casting their housing. The article presents the principle of operation of the test stand and the process of preparation for the casting and the cast itself will be rudely described. Due to the implementation of research as part of a research project with an industrial partner, the article will only describe some operations. This is related to the confidentiality of the project.

  5. Experimental Evaluation of Balance Prediction Models for Sit-to-Stand Movement in the Sagittal Plane

    Directory of Open Access Journals (Sweden)

    Oscar David Pena Cabra

    2013-01-01

    Full Text Available Evaluation of balance control ability would become important in the rehabilitation training. In this paper, in order to make clear usefulness and limitation of a traditional simple inverted pendulum model in balance prediction in sit-to-stand movements, the traditional simple model was compared to an inertia (rotational radius variable inverted pendulum model including multiple-joint influence in the balance predictions. The predictions were tested upon experimentation with six healthy subjects. The evaluation showed that the multiple-joint influence model is more accurate in predicting balance under demanding sit-to-stand conditions. On the other hand, the evaluation also showed that the traditionally used simple inverted pendulum model is still reliable in predicting balance during sit-to-stand movement under non-demanding (normal condition. Especially, the simple model was shown to be effective for sit-to-stand movements with low center of mass velocity at the seat-off. Moreover, almost all trajectories under the normal condition seemed to follow the same control strategy, in which the subjects used extra energy than the minimum one necessary for standing up. This suggests that the safety considerations come first than the energy efficiency considerations during a sit to stand, since the most energy efficient trajectory is close to the backward fall boundary.

  6. Thin film free-standing PEDOT:PSS/SU8 bilayer microactuators

    International Nuclear Information System (INIS)

    Taccola, S; Greco, F; Mazzolai, B; Mattoli, V; Jager, E W H

    2013-01-01

    Several smart active materials have been proposed and tested for the development of microactuators. Among these, conjugated polymers are of great interest because miniaturization improves their electrochemical properties, such as increasing the speed and stress output of microactuators, with respect to large-scale actuators. Recently we developed a novel fabrication process to obtain robust free-standing conductive ultra-thin films made of the conjugated polymer poly(3, 4-ethylenedioxythiophene) doped with the polyanion poly(styrenesulfonate) (PEDOT:PSS). These conductive free-standing nanofilms, with thicknesses ranging between a few tens to several hundreds of nm, allow the realisation of new all polymer microactuators using facile microfabrication methods. Here, we report a novel processing method for manufacturing all polymer electrochemical microactuators. We fabricated and patterned free-standing PEDOT:PSS/SU8 bilayer microactuators in the form of microfingers of a variety of lengths using adapted microfabrication procedures. By imposing electrochemical oxidation/reduction cycles on the PEDOT:PSS we were able to demonstrate reversible actuation of the microactuators resulting in bending of the microfingers. A number of possible applications can be envisaged for these small, soft actuators, such as microrobotics and cell manipulation. (technical note)

  7. Improvement of Stand Jig Sealer and Its Increased Production Capacity

    Science.gov (United States)

    Soebandrija, K. E. N.; Astuti, S. W. D.

    2014-03-01

    This paper has the objective to prove that improvement of Stand Jig Sealer can lead to the cycle time target as part of Improvement efforts and its Productivity. Prior researches through prior journals both classics journal such as Quesnay (1766) and Solow (1957) and updated journal such as Reikard (2011) researches, are mentioned and elaborated. Precisely, the research is narrowed down and specified into automotive industry and eventually the software related of SPSS and Structural Equation Modeling ( SEM ). The analysis and its method are conducted through the calculation working time. The mentioned calculation are reinforced with the hypothesis test using SPSS Version 19 and involve parameters of production efficiency, productivity calculation, and the calculation of financial investments. The results obtained are augmented achievement of cycle time target ≤ 80 seconds posterior to improvement stand jig sealer. The result from calculation of SPSS-19 version comprise the following aspects: the one-sided hypothesis test is rejection of Ho:μ≥80 seconds, the correlation rs=0.84, regression y = 0.159+0.642x, validity R table = 0.4438, reliability value of Cronbach's alpha = 0.885>0.70, independence (Chi Square) Asymp. Sig=0.028financial analysis (NPV 2,340,596>0, PI 2.04>1, IRR 45.56%>i=12.68%, PP=1.86). The Mentioned calculation results support the hypothesis and ultimately align with the objective of this paper to prove that improvement of Stand Jig Sealer and its relation toward the cycle time target. Precisely, the improvement of production capacity of PT. Astra Daihatsu Motor.

  8. Validation of Cardiovascular Parameters during NASA's Functional Task Test

    Science.gov (United States)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, S. H.

    2009-01-01

    Microgravity exposure causes physiological deconditioning and impairs crewmember task performance. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in a series of operationally-relevant tasks. One of these, the Recovery from Fall/Stand Test (RFST), tests both the ability to recover from a prone position and cardiovascular responses to orthostasis. PURPOSE: Three minutes were chosen for the duration of this test, yet it is unknown if this is long enough to induce cardiovascular responses similar to the operational 5 min stand test. The purpose of this study was to determine the validity and reliability of heart rate variability (HRV) analysis of a 3 min stand and to examine the effect of spaceflight on these measures. METHODS: To determine the validity of using 3 vs. 5 min of standing to assess HRV, ECG was collected from 7 healthy subjects who participated in a 6 min RFST. Mean R-R interval (RR) and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the FTT on separate days, including the RFST with a 3 min stand. Analysis of variance (ANOVA) was performed on the HRV measures. One crewmember completed the FTT before a 14-day mission, on landing day (R+0) and one (R+1) day after returning to Earth. RESULTS VALIDITY: HRV measures reflecting autonomic activity were not significantly different during the 0-3 and 0-5 min segments. RELIABILITY: The average coefficient of variation for RR, systolic (SBP) and diastolic blood pressures during the RFST were less than 8% for the 3 sessions. ANOVA results yielded a greater inter-subject variability (p0.05) for HRV in the RFST. SPACEFLIGHT: Lower RR and higher SBP were observed on R+0 in rest and stand. On R+1, both RR and SBP trended towards preflight

  9. Assessment of Muscle Fatigue Associated with Prolonged Standing in the Workplace

    Science.gov (United States)

    Omar, Abdul Rahman; Saman, Alias Mohd; Othman, Ibrahim

    2012-01-01

    Objectives The objectives of this study were to determine the psychological fatigue and analyze muscle activity of production workers who are performing processes jobs while standing for prolonged time periods. Methods The psychological fatigue experienced by the workers was obtained through questionnaire surveys. Meanwhile, muscle activity has been analyzed using surface electromyography (sEMG) measurement. Lower extremities muscles include: erector spinae, tibialis anterior, and gastrocnemius were concurrently measured for more than five hours of standing. Twenty male production workers in a metal stamping company participated as subjects in this study. The subjects were required to undergo questionnaire surveys and sEMG measurement. Results Results of the questionnaire surveys found that all subjects experienced psychological fatigue due to prolonged standing jobs. Similarly, muscle fatigue has been identified through sEMG measurement. Based on the non-parametric statistical test using the Spearman's rank order correlation, the left erector spinae obtained a moderate positive correlation and statistically significant (rs = 0.552, p fatigue and to muscle fatigue among the production workers. PMID:22953228

  10. Analysis of forest stands used by wintering woodland caribou in Ontario

    Directory of Open Access Journals (Sweden)

    K. Antoniak

    1998-03-01

    Full Text Available Two summers' field surveys at 9 locations in northwestern Ontario showed that woodland caribou (Rangifer tarandus caribou wintering areas supported jack pine and black spruce stands with low tree densities (mean 1552 trees/ ha, 39% of a fully stocked stand, low basal areas (mean 14.14 m2/ha, low volumes (mean 116 mVha, 68% of Normal Yield Tables and short heights (95% of stands 12 m or less. Ecologically, most sights were classed V30. Significantly more lichen (averaging 39% lichen ground cover was found on plots used by caribou. Three measured areas showed few shrubs, possibly enhancing escape possibilities and reducing browse attractive to moose. An HIS model predicted known locations of caribou winter habitat from FRI data with 76% accuracy. Landsat imagery theme 3 (open conifer produced 74% accuracy. Combining these methods permitted prediction of all 50 test sites. The low volumes of timber found in caribou wintering areas suggest that setting aside reserves for caribou winter habitat would not sacrifice as much wood product value as might at first appear.

  11. First Stage Acceptance Test

    Science.gov (United States)

    1960-01-01

    This photograph shows the intense smoke and fire created by the five F-1 engines from a test firing of the Saturn V first stage (S-1C) in the S-1C test stand at the Marshall Space Flight Center. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  12. Stand-alone XLIF

    DEFF Research Database (Denmark)

    Hansen, E. J.; Simony, A.; Hummel, Stefan

    2015-01-01

    and clinical/radiological results in 22 patients treated with XLIF procedure for DS or degenerative disc disease (DDD). Material and methods: 22 consecutive patients with DS underwent surgery with the XLIF stand-alone procedure, with follow-up of 24 months. Clinical outcome scores were collected. Complications......Introduction: Adult thoracolumbar degeneration is an increasing challenge in the aging population. With age the progressive degeneration of the discs leads to an asymmetric collapse and a thoracolumbar coronal plane deformity, a degenerative scoliosis (DS). Aim: To evaluate the complication rate......-year follow-up, with a 31.8% revision rate. Due to the high revision rate we recommend supplementary posterior instrumentation, to achieve a higher fusion rate. When considering XLIF-stand-alone procedure for DS or DDD without supplemental posterior instrumentation, only single-level disease should...

  13. Flexible integration of free-standing nanowires into silicon photonics.

    Science.gov (United States)

    Chen, Bigeng; Wu, Hao; Xin, Chenguang; Dai, Daoxin; Tong, Limin

    2017-06-14

    Silicon photonics has been developed successfully with a top-down fabrication technique to enable large-scale photonic integrated circuits with high reproducibility, but is limited intrinsically by the material capability for active or nonlinear applications. On the other hand, free-standing nanowires synthesized via a bottom-up growth present great material diversity and structural uniformity, but precisely assembling free-standing nanowires for on-demand photonic functionality remains a great challenge. Here we report hybrid integration of free-standing nanowires into silicon photonics with high flexibility by coupling free-standing nanowires onto target silicon waveguides that are simultaneously used for precise positioning. Coupling efficiency between a free-standing nanowire and a silicon waveguide is up to ~97% in the telecommunication band. A hybrid nonlinear-free-standing nanowires-silicon waveguides Mach-Zehnder interferometer and a racetrack resonator for significantly enhanced optical modulation are experimentally demonstrated, as well as hybrid active-free-standing nanowires-silicon waveguides circuits for light generation. These results suggest an alternative approach to flexible multifunctional on-chip nanophotonic devices.Precisely assembling free-standing nanowires for on-demand photonic functionality remains a challenge. Here, Chen et al. integrate free-standing nanowires into silicon waveguides and show all-optical modulation and light generation on silicon photonic chips.

  14. Desk-based workers' perspectives on using sit-stand workstations: a qualitative analysis of the Stand@Work study

    NARCIS (Netherlands)

    Chau, J.Y.; Daley, M.; Srinivasan, A.; Dunn, S.; Bauman, A.E.; van der Ploeg, H.P.

    2014-01-01

    Background: Prolonged sitting time has been identified as a health risk factor. Sit-stand workstations allow desk workers to alternate between sitting and standing throughout the working day, but not much is known about their acceptability and feasibility. Hence, the aim of this study was to

  15. The eye-complaint questionnaire in a visual display unit work environment: Internal consistency and test-retest reliability

    NARCIS (Netherlands)

    Steenstra, Ivan A.; Sluiter, Judith K.; Frings-Dresen, Monique H. W.

    2009-01-01

    The internal consistency and test-retest reliability of a 10-item eye-complaint questionnaire (ECQ) were examined within a sample of office workers. Repeated within-subjects measures were performed within a single day and over intervals of 1 and 7 d. Questionnaires were completed by 96 workers (70%

  16. Design and construction of the SSCL magnet test laboratory cryogenic systems

    International Nuclear Information System (INIS)

    Freeman, M.A.; Kobel, T.A.

    1992-01-01

    The intent of this document is to provide a brief summary of the execution, by Process Systems International, Inc. (PSI), of the Design and Construction of the SSCL Magnet Test Laboratory Cryogenic Systems. This $30 million project requires the expenditure of over 200,000 manhours and the procurement of $17 million in materials within a two year period. SSC magnets will be performance tested at the Magnet Test Laboratory (MTL) and the Accelerator System String Test (ASST) facility under conditions simulating the environment of the SSC main ring. The cryogenic system consists of test stands (five for MTL, one for ASST) and the associated equipment including cryogenic storage, purification, thermal conditioning, and helium refrigeration necessary to support the test program

  17. Variations in rest vertical dimension: effects of standing posture in edentulous patients.

    Science.gov (United States)

    Makzoume, Joseph E

    2007-01-01

    The orientation of a patient's head changes, depending on whether he or she is sitting or standing in a relaxed upright position. An edentulous patient's vertical dimension at rest may show variations that can result in an inaccurate determination of his or her occlusal vertical dimension. This study recorded the rest vertical dimension (RVD) established among 60 totally edentulous subjects who were standing in the position of greatest comfort (self-balance position) and compared it with the patients' RVD when they were seated in a relaxed upright position, with the Frankfort Plane parallel to the horizontal. The RVD was measured (in mm) between two dots located on the midline of the face. Two measurements were made: one when the patient was seated upright and relaxed (with the Frankfort Plane parallel to the horizontal) with no head support, and the other when the patient was standing relaxed on both feet in a self-balance position. Five alternated measurements were made for each subject in each position. A mean RVD was calculated for each subject in each body posture and the mean values from both positions were compared. Statistical analysis was performed using Student's t-test (alpha = 0.05). No significant differences were noted between the RVD of the seated and standing positions (P = 0.67).

  18. Multi-muscle electrical stimulation and stand training: Effects on standing.

    Science.gov (United States)

    Momeni, Kamyar; Ramanujam, Arvind; Garbarini, Erica L; Forrest, Gail F

    2018-02-15

    To examine the biomechanical and neuromuscular effects of a longitudinal multi-muscle electrical stimulation (submaximal intensities) training of the lower limbs combined with/without activity-based stand training, on the recovery of stability and function for one individual with spinal cord injury (SCI). Single-subject, longitudinal study. Neuroplasticity laboratory. A 34-year-old male, with sensory- and motor-complete SCI (C5/C6). Two consecutive interventions: 61 hours of supine, lower-limb ES (ES-alone) and 51 hours of ES combined with stand training using an overhead body-weight support system (ST + ES). Clinical measures, trunk stability, and muscle activity were assessed and compared across time points. Trunk Stability Limit (TSL) determined improvements in trunk independence. Functional clinical values increased after both interventions, with further increases post ST + ES. Post ES-alone, trunk stability was maintained at 81% body-weight (BW) loading before failure; post ST + ES, BW loading increased to 95%. TSL values decreased post ST + ES (TSL A/P =54.0 kg.cm, TSL M/L =14.5 kg.cm), compared to ES-alone (TSL A/P =8.5 kg.cm, TSL M/L =3.9 kg.cm). Trunk muscle activity decreased post ST + ES training, compared to ES-alone. Neuromuscular and postural trunk control dramatically improved following the multi-muscle ES of the lower limbs with stand training. Multi-muscle ES training paradigm of the lower limb, using traditional parameters, may contribute to the functional recovery of the trunk.

  19. A method to achieve comparable thermal states of car brakes during braking on the road and on a high-speed roll-stand

    Science.gov (United States)

    Wolff, Andrzej

    2010-01-01

    The temperature of a brake friction surface influences significantly the braking effectiveness. The paper describes a heat transfer process in car brakes. Using a developed program of finite element method, the temperature distributions in brake rotors (disc and drum brake) of a light truck have been calculated. As a preliminary consistency criterion of the brake thermal state in road and roll-stand braking conditions, a balance of the energy cumulated in the brake rotor has been taken into account. As the most reliable consistency criterion an equality of average temperatures of the friction surface has been assumed. The presented method allows to achieve on a roll-stand the analogical thermal states of automotive brakes, which are observed during braking in road conditions. Basing on this method, it is possible to calculate the braking time and force for a high-speed roll-stand. In contrast to the previous papers of the author, new calculation results have been presented.

  20. Sapwood area ofPinus contorta stands as a function of mean size and density.

    Science.gov (United States)

    Long, James N; Dean, Thomas J

    1986-09-01

    An indirect test of the relationship between leaf area and the combination of mean size and density is made in stands of lodgepole pine (Pinus contorta Dougl.). Total sapwood cross-sectional area of these stands is a function of the product of density and mean diameter raised to an exponent of about 1.6. Results from other studies, representing four species, suggest that this relationship between sapwood area and the combination of mean size and density may be general. The implications of the relationship are discussed in the context of evapotranspiration, competition and self-thinning.

  1. Management alternatives of energy wood thinning stands

    International Nuclear Information System (INIS)

    Heikkilae, Jani; Siren, Matti; Aeijaelae, Olli

    2007-01-01

    Energy wood thinning has become a feasible treatment alternative of young stands in Finland. Energy wood thinnings have been carried out mainly in stands where precommercial thinning has been neglected and the harvesting conditions for industrial wood thinning are difficult. Despite of its positive effects on harvesting costs and on renewable energy potential, whole-tree harvesting has been constantly criticized for causing growth loss. In this paper, the profitability of energy wood thinning was studied in 20 Scots pine-dominated stands where energy wood thinning was carried out. The growth of the stands after thinning was predicted with the help of Motti-stand simulator. Entire rotation time of the stands was simulated with different management alternatives. The intensity of first thinning and recovery level of logging residues varied between alternatives. In order to attain acceptable harvesting conditions, industrial wood thinning had to be delayed. The effect of energy wood thinning on subsequent stem wood growth was almost the same as in conventional thinning. Whole-tree harvesting for energy proved to be profitable alternative if the stumpage price is around 3EUR m -3 , the interest rate is 3% or 5% and the removal of pulpwood is less than 20 m 3 ha -1 . If the harvestable pulpwood yield is over 20 m 3 ha -1 , integrated harvesting of industrial and energy wood or delayed industrial wood harvesting becomes more profitable. (author)

  2. An empirical analysis of the physical aptitude exam as a predictor of performance on the Physical Readiness Test

    OpenAIRE

    Patrick, Robert W.

    2000-01-01

    The Physical Aptitude Exam, administered to candidates in the Naval Academy admissions process to measure physical aptitude, consists of pullups for men or the flexed arm hang for women, a 300-yard shuttle run, a standing longiump, and a kneeling basketball throw. The Physical Readiness Test, administered semi-annually to all naval personnel including midshipmen, consists of modified situps, pushups, and a 1.5-mile run. The purpose of this research is to determine if the Physical Aptitude Exa...

  3. Transpalpebral eye enucleation in the standing horse

    DEFF Research Database (Denmark)

    Christophersen, Mogens Teken

    Transpalpebral eye enucleation in the standing horse. The Nordic Equine Veterinary Conference, Proceedings, Copenhagen. Denmark. Nov. 2011.......Transpalpebral eye enucleation in the standing horse. The Nordic Equine Veterinary Conference, Proceedings, Copenhagen. Denmark. Nov. 2011....

  4. Stocking equations for regeneration in mixed oak stands

    Science.gov (United States)

    Songlin Fei; Kim C. Steiner; James C. Finley

    2007-01-01

    Regeneration stocking equations for mixed-oak stands were developed based on data collected from nearly 14,000 plots in the central Appalachians. Maximum stand density was identified by plotting aggregate height against number of seedlings per plot, and was used as the reference level of the average maximum stand density (100 percent stocking or A-level stocking)....

  5. Respiratory Syncytial Virus (RSV) Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/respiratorysyncytialvirusrsvtest.html Respiratory Syncytial Virus (RSV) Test To use the sharing ... is an RSV test? RSV , which stands for respiratory syncytial virus, is an infection that affects the ...

  6. Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly.

    Directory of Open Access Journals (Sweden)

    Jantsje H Pasma

    Full Text Available System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system identification techniques.In twelve healthy elderly balance tests were performed twice a day during three days. Body sway was measured during two minutes of standing with eyes closed and the Balance test Room (BalRoom was used to apply four disturbances simultaneously: two sensory disturbances, to the proprioceptive and the visual system, and two mechanical disturbances applied at the leg and trunk segment. Using system identification techniques, sensitivity functions of the sensory disturbances and the neuromuscular controller were estimated. Based on the generalizability theory (G theory, systematic errors and sources of variability were assessed using linear mixed models and reliability was assessed by computing indexes of dependability (ID, standard error of measurement (SEM and minimal detectable change (MDC.A systematic error was found between the first and second trial in the sensitivity functions. No systematic error was found in the neuromuscular controller and body sway. The reliability of 15 of 25 parameters and body sway were moderate to excellent when the results of two trials on three days were averaged. To reach an excellent reliability on one day in 7 out of 25 parameters, it was predicted that at least seven trials must be averaged.This study shows that system identification techniques are a promising method to assess the underlying systems involved in standing balance in elderly. However, most of the parameters do not appear to be reliable unless a large number of trials are collected across multiple days. To reach an excellent reliability in one third of the parameters, a training session for participants is needed and at least seven trials of two

  7. Juvenile offenders: competence to stand trial.

    Science.gov (United States)

    Soulier, Matthew

    2012-12-01

    This article details the legal background and assists the reader in the preparation and practical conduct of evaluations regarding juvenile adjudicative competency. The material is presented to be useful as a guide to direct questions of competency and covers aspects of evaluation that include: legal standard for competency to stand trial, developmental immaturity, current practice in juvenile competency to stand trial, forensic evaluation of juvenile competency to stand trial, organizing the evaluation, collateral sources of information, psychiatric evaluation of juvenile adjudicative competency, assessment of mental disorder and intellectual disability, assessment of developmental status, assessment of functional abilities for adjudicative competence, and reaching the forensic opinion. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Revisiting the difference between traveling-wave and standing-wave thermoacoustic engines - A simple analytical model for the standing-wave one

    Science.gov (United States)

    Yasui, Kyuichi; Kozuka, Teruyuki; Yasuoka, Masaki; Kato, Kazumi

    2015-11-01

    There are two major categories in a thermoacoustic prime-mover. One is the traveling-wave type and the other is the standing-wave type. A simple analytical model of a standing-wave thermoacoustic prime-mover is proposed at relatively low heat-flux for a stack much shorter than the acoustic wavelength, which approximately describes the Brayton cycle. Numerical simulations of Rott's equations have revealed that the work flow (acoustic power) increases by increasing of the amplitude of the particle velocity (| U|) for the traveling-wave type and by increasing cosΦ for the standing-wave type, where Φ is the phase difference between the particle velocity and the acoustic pressure. In other words, the standing-wave type is a phase-dominant type while the traveling-wave type is an amplitude-dominant one. The ratio of the absolute value of the traveling-wave component (| U|cosΦ) to that of the standing-wave component (| U|sinΦ) of any thermoacoustic engine roughly equals the ratio of the absolute value of the increasing rate of | U| to that of cosΦ. The different mechanism between the traveling-wave and the standing-wave type is discussed regarding the dependence of the energy efficiency on the acoustic impedance of a stack as well as that on ωτα, where ω is the angular frequency of an acoustic wave and τα is the thermal relaxation time. While the energy efficiency of the traveling-wave type at the optimal ωτα is much higher than that of the standing-wave type, the energy efficiency of the standing-wave type is higher than that of the traveling-wave type at much higher ωτα under a fixed temperature difference between the cold and the hot ends of the stack.

  9. Solar Charged Stand Alone Inverter

    OpenAIRE

    M.Vasugi; Prof R.Jayaraman

    2014-01-01

    This paper deals with solar powered stand alone inverter which converts the variable dc output of a photovoltaic solar panel into ac that can be fed to loads. Stand alone inverters are used in systems where the inverter get its energy from batteries charged by photo voltaic arrays. A charge controller limits the rate at which electric current is added to or drawn from electric batteries. This charge discharge controller is needed to prevent the battery from being overcharged o...

  10. Internal consistency, reliability, and temporal stability of the Oxford Happiness Questionnaire short-form: Test-retest data over two weeks

    OpenAIRE

    MCGUCKIN, CONOR

    2006-01-01

    PUBLISHED The Oxford Happiness Questionnaire short-form is a recently developed eight-item measure of happiness. This study evaluated the internal consistency reliability and test-retest reliability of the Oxford Happiness Questionnaire short-form among 55 Northern Irish undergraduate university students who completed the measure on two occasions separated by two weeks. Internal consistency of the measure on both occasions was satisfactory at both Time 1 (alpha = .62) and Time 2 (alpha = ....

  11. The effect of medial arch support over the plantar pressure and triceps surae muscle strength after prolonged standing

    Directory of Open Access Journals (Sweden)

    Hindun Saadah

    2015-11-01

    Full Text Available Background: The activity with prolonged standing position is one of the causes of abnormalities in the lower leg and foot. The aim of this study is to discover the effect of medial arch support over the distribution of plantar pressure when standing and walking.Methods: This was an experimental study with pre- and post-design the strength of triceps surae muscle after prolonged standing, was also evaluated in an experimental study with pre- and post-design. Variables of plantar pressure measurement are the contact area and pressure peak were measured by using the Mat-scan tool. The measurement of the triceps surae muscle strength was done with a hand-held dynamometer, before and after using the medial arch support. Measurement was performed before and after working with prolonged standing position which took place about seven hours using the medial arch support inserted in the shoes. Data was analyzed using paired T-test.Results: There was a significant difference of peak pressure between standing (p = 0.041 and walking (p = 0.001. Whereas the contact area showed a significant decrease in the width of the contact area when standing (104.12 ± 12.42 vs 99.08 ± 10.21 p = 0.023. Whereas, the triceps surae muscle strength pre- and post-standing prolonged did not indicate a significant difference.Conclusion: There was decrease in peak pressure when standing and walking and decrease in contact area when standing on plantar after used of the medial arch support after prolonged standing.

  12. REFINEMENT OF THE REVERSE EXTRUSION TEST TO DETERMINE THE TWO CONSISTENCY LIMITS

    Directory of Open Access Journals (Sweden)

    Kamil KAYABALI

    2015-11-01

    coefficients (i.e., a and b were subjected to a multiple regression analysis along with the results of the conventional testing methods of fall-cone and rolling-device to determine the LL and PL as functions of the reverse extrusion parameters. It was shown that LL and PL can be predicted with a great degree of success using the reverse extrusion coefficients. While a great majority of the liquid limits found by using the fall-cone method were predicted with a ±10% error, almost all of the plastic limits found by the rolling device were predicted with a ±10% error. This refined investigation on the reverse extrusion test confirmed and proved that the reverse extrusion test is a simple, robust and inexpensive method capable of predicting both of two fundamental consistency limits using a single device.

  13. Project NEO Specific Impulse Testing Solutions

    Science.gov (United States)

    Baffa, Bill

    2018-01-01

    The Neo test stand is currently configured to fire a horizontally mounted rocket motor with up to 6500 lbf thrust. Currently, the Neo test stand can measure flow of liquid propellant and oxidizer, pressures residing in the closed system up to the combustion chamber. The current configuration does not have the ability to provide all data needed to compute specific impulse. This presents three methods to outfit the NEO test fixture with instrumentation allowing for calculation of specific impulse.

  14. Evaluating growth performance of young stands

    Science.gov (United States)

    A. L. Roe; R. E. Benson

    1966-01-01

    A simple procedure for evaluating the diameter growth of young stands in relation to potential growth is described. A comparison technique is developed which contrasts relative diameter of crop trees to the relative diameter growth of the last decade to show the condition and trend of growth in the stand. The method is objective, easy to use, and has several...

  15. Student Effort, Consistency and Online Performance

    Directory of Open Access Journals (Sweden)

    Hilde Patron

    2011-07-01

    Full Text Available This paper examines how student effort, consistency, motivation, and marginal learning, influence student grades in an online course. We use data from eleven Microeconomics courses taught online for a total of 212 students. Our findings show that consistency, or less time variation, is a statistically significant explanatory variable, whereas effort, or total minutes spent online, is not. Other independent variables include GPA and the difference between a pre-test and a post-test. The GPA is used as a measure of motivation, and the difference between a post-test and pre-test as marginal learning. As expected, the level of motivation is found statistically significant at a 99% confidence level, and marginal learning is also significant at a 95% level.

  16. Effect of different tree mortality patterns on stand development in the forest model SIBYLA

    Directory of Open Access Journals (Sweden)

    Trombik Jiří

    2016-09-01

    Full Text Available Forest mortality critically affects stand structure and the quality of ecosystem services provided by forests. Spruce bark beetle (Ips typographus generates rather complex infestation and mortality patterns, and implementation of such patterns in forest models is challenging. We present here the procedure, which allows to simulate the bark beetle-related tree mortality in the forest dynamics model Sibyla. We explored how sensitive various production and stand structure indicators are to tree mortality patterns, which can be generated by bark beetles. We compared the simulation outputs for three unmanaged forest stands with 40, 70 and 100% proportion of spruce as affected by the disturbance-related mortality that occurred in a random pattern and in a patchy pattern. The used tree species and age class-specific mortality rates were derived from the disturbance-related mortality records from Slovakia. The proposed algorithm was developed in the SQLite using the Python language, and the algorithm allowed us to define the degree of spatial clustering of dead trees ranging from a random distribution to a completely clustered distribution; a number of trees that died in either mode is set to remain equal. We found significant differences between the long-term developments of the three investigated forest stands, but we found very little effect of the tested mortality modes on stand increment, tree species composition and diversity, and tree size diversity. Hence, our hypothesis that the different pattern of dead trees emergence should affect the competitive interactions between trees and regeneration, and thus affect selected productivity and stand structure indicators was not confirmed.

  17. Free-standing and mechanically flexible mats consisting of electrospun carbon nanofibers made from a natural product of alkali lignin as binder-free electrodes for high-performance supercapacitors

    Science.gov (United States)

    Lai, Chuilin; Zhou, Zhengping; Zhang, Lifeng; Wang, Xiaoxu; Zhou, Qixin; Zhao, Yong; Wang, Yechun; Wu, Xiang-Fa; Zhu, Zhengtao; Fong, Hao

    2014-02-01

    Mechanically flexible mats consisting of electrospun carbon nanofibers (ECNFs) were prepared by first electrospinning aqueous mixtures containing a natural product of alkali lignin together with polyvinyl alcohol (PVA) into composite nanofiber mats followed by stabilization in air and carbonization in an inert environment. Morphological and structural properties, as well as specific surface area, total pore volume, average pore size, and pore size distribution, of the lignin-based ECNF mats were characterized; and their electrochemical performances (i.e., capacitive behaviors) were evaluated by cyclic voltammetry, galvanostatic charge/discharge, and electrochemical impedance spectroscopy. The lignin-based ECNF mats exhibited outstanding performance as free-standing and/or binder-free electrodes of supercapacitors. For example, the ECNFs made from the composite nanofibers with mass ratio of lignin/PVA being 70/30 (i.e., ECNFs (70/30)) had the average diameter of ∼100 nm and the Brunauer-Emmett-Teller (BET) specific surface area of ∼583 m2 g-1. The gravimetric capacitance of ECNFs (70/30) electrode in 6 M KOH aqueous electrolyte exhibited 64 F g-1 at current density of 400 mA g-1 and 50 F g-1 at 2000 mA g-1. The ECNFs (70/30) electrode also exhibited excellent cycling durability/stability, and the gravimetric capacitance merely reduced by ∼10% after 6000 cycles of charge/discharge.

  18. Modelling Variable Fire Severity in Boreal Forests: Effects of Fire Intensity and Stand Structure.

    Science.gov (United States)

    Miquelajauregui, Yosune; Cumming, Steven G; Gauthier, Sylvie

    2016-01-01

    It is becoming clear that fires in boreal forests are not uniformly stand-replacing. On the contrary, marked variation in fire severity, measured as tree mortality, has been found both within and among individual fires. It is important to understand the conditions under which this variation can arise. We integrated forest sample plot data, tree allometries and historical forest fire records within a diameter class-structured model of 1.0 ha patches of mono-specific black spruce and jack pine stands in northern Québec, Canada. The model accounts for crown fire initiation and vertical spread into the canopy. It uses empirical relations between fire intensity, scorch height, the percent of crown scorched and tree mortality to simulate fire severity, specifically the percent reduction in patch basal area due to fire-caused mortality. A random forest and a regression tree analysis of a large random sample of simulated fires were used to test for an effect of fireline intensity, stand structure, species composition and pyrogeographic regions on resultant severity. Severity increased with intensity and was lower for jack pine stands. The proportion of simulated fires that burned at high severity (e.g. >75% reduction in patch basal area) was 0.80 for black spruce and 0.11 for jack pine. We identified thresholds in intensity below which there was a marked sensitivity of simulated fire severity to stand structure, and to interactions between intensity and structure. We found no evidence for a residual effect of pyrogeographic region on simulated severity, after the effects of stand structure and species composition were accounted for. The model presented here was able to produce variation in fire severity under a range of fire intensity conditions. This suggests that variation in stand structure is one of the factors causing the observed variation in boreal fire severity.

  19. Effect of Core Stability Training on Trunk Function, Standing Balance, and Mobility in Stroke Patients.

    Science.gov (United States)

    Haruyama, Koshiro; Kawakami, Michiyuki; Otsuka, Tomoyoshi

    2017-03-01

    Trunk function is important for standing balance, mobility, and functional outcome after stroke, but few studies have evaluated the effects of exercises aimed at improving core stability in stroke patients. To investigate the effectiveness of core stability training on trunk function, standing balance, and mobility in stroke patients. An assessor-blinded, randomized controlled trial was undertaken in a stroke rehabilitation ward, with 32 participants randomly assigned to an experimental group or a control group (n = 16 each). The experimental group received 400 minutes of core stability training in place of conventional programs within total training time, while the control group received only conventional programs. Primary outcome measures were evaluated using the Trunk Impairment Scale (TIS), which reflects trunk function. Secondary outcome measures were evaluated by pelvic tilt active range of motion in the sagittal plane, the Balance Evaluation Systems Test-brief version (Brief-BESTest), Functional Reach test, Timed Up-and-Go test (TUG), and Functional Ambulation Categories (FAC). A general linear repeated-measures model was used to analyze the results. A treatment effect was found for the experimental group on the dynamic balance subscale and total score of the TIS ( P = .002 and P Core stability training has beneficial effects on trunk function, standing balance, and mobility in stroke patients. Our findings might provide support for introducing core stability training in stroke rehabilitation.

  20. Space Launch System, Core Stage, Structural Test Design and Implementation

    Science.gov (United States)

    Shaughnessy, Ray

    2017-01-01

    As part of the National Aeronautics and Space Administration's (NASA) Space Launch System (SLS) Program, engineers at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama are working to design, develop and implement the SLS Core Stage structural testing. The SLS will have the capability to return humans to the Moon and beyond and its first launch is scheduled for December of 2017. The SLS Core Stage consist of five major elements; Forward Skirt, Liquid Oxygen (LOX) tank, Intertank (IT), Liquid Hydrogen (LH2) tank and the Engine Section (ES). Structural Test Articles (STA) for each of these elements are being designed and produced by Boeing at Michoud Assembly Facility located in New Orleans, La. The structural test for the Core Stage STAs (LH2, LOX, IT and ES) are to be conducted by the MSFC Test Laboratory. Additionally, the MSFC Test Laboratory manages the Structural Test Equipment (STE) design and development to support the STAs. It was decided early (April 2012) in the project life that the LH2 and LOX tank STAs would require new test stands and the Engine Section and Intertank would be tested in existing facilities. This decision impacted schedules immediately because the new facilities would require Construction of Facilities (C of F) funds that require congressional approval and long lead times. The Engine Section and Intertank structural test are to be conducted in existing facilities which will limit lead times required to support the first launch of SLS. With a SLS launch date of December, 2017 Boeing had a need date for testing to be complete by September of 2017 to support flight certification requirements. The test facilities were required to be ready by October of 2016 to support test article delivery. The race was on to get the stands ready before Test Article delivery and meet the test complete date of September 2017. This paper documents the past and current design and development phases and the supporting processes, tools, and

  1. Improvement in the physiological function and standing stability based on kinect multimedia for older people.

    Science.gov (United States)

    Chen, Chih-Chen

    2016-04-01

    [Purpose] The increase in the Taiwanese older population is associated with age-related inconveniences. Finding adequate and simple physical activities to help the older people maintaining their physiological function and preventing them from falls has become an urgent social issue. [Subjects and Methods] This study aimed to design a virtual exercise training game suitable for Taiwanese older people. This system will allow for the maintenance of the physiological function and standing stability through physical exercise, while using a virtual reality game. The participants can easily exercise in a carefree, interactive environment. This study will use Kinect for Windows for physical movement detection and Unity software for virtual world development. [Results] Group A and B subjects were involved in the exercise training method of Kinect interactive multimedia for 12 weeks. The results showed that the functional reach test and the unipedal stance test improved significantly. [Conclusion] The physiological function and standing stability of the group A subjects were examined at six weeks post training. The results showed that these parameters remained constant. This proved that the proposed system provide substantial support toward the preservation of the Taiwanese older people' physiological function and standing stability.

  2. Quantifying climate-growth relationships at the stand level in a mature mixed-species conifer forest.

    Science.gov (United States)

    Teets, Aaron; Fraver, Shawn; Weiskittel, Aaron R; Hollinger, David Y

    2018-03-11

    A range of environmental factors regulate tree growth; however, climate is generally thought to most strongly influence year-to-year variability in growth. Numerous dendrochronological (tree-ring) studies have identified climate factors that influence year-to-year variability in growth for given tree species and location. However, traditional dendrochronology methods have limitations that prevent them from adequately assessing stand-level (as opposed to species-level) growth. We argue that stand-level growth analyses provide a more meaningful assessment of forest response to climate fluctuations, as well as the management options that may be employed to sustain forest productivity. Working in a mature, mixed-species stand at the Howland Research Forest of central Maine, USA, we used two alternatives to traditional dendrochronological analyses by (1) selecting trees for coring using a stratified (by size and species), random sampling method that ensures a representative sample of the stand, and (2) converting ring widths to biomass increments, which once summed, produced a representation of stand-level growth, while maintaining species identities or canopy position if needed. We then tested the relative influence of seasonal climate variables on year-to-year variability in the biomass increment using generalized least squares regression, while accounting for temporal autocorrelation. Our results indicate that stand-level growth responded most strongly to previous summer and current spring climate variables, resulting from a combination of individualistic climate responses occurring at the species- and canopy-position level. Our climate models were better fit to stand-level biomass increment than to species-level or canopy-position summaries. The relative growth responses (i.e., percent change) predicted from the most influential climate variables indicate stand-level growth varies less from to year-to-year than species-level or canopy-position growth responses. By

  3. The Multivariate Largest Lyapunov Exponent as an Age-Related Metric of Quiet Standing Balance

    Directory of Open Access Journals (Sweden)

    Kun Liu

    2015-01-01

    Full Text Available The largest Lyapunov exponent has been researched as a metric of the balance ability during human quiet standing. However, the sensitivity and accuracy of this measurement method are not good enough for clinical use. The present research proposes a metric of the human body’s standing balance ability based on the multivariate largest Lyapunov exponent which can quantify the human standing balance. The dynamic multivariate time series of ankle, knee, and hip were measured by multiple electrical goniometers. Thirty-six normal people of different ages participated in the test. With acquired data, the multivariate largest Lyapunov exponent was calculated. Finally, the results of the proposed approach were analysed and compared with the traditional method, for which the largest Lyapunov exponent and power spectral density from the centre of pressure were also calculated. The following conclusions can be obtained. The multivariate largest Lyapunov exponent has a higher degree of differentiation in differentiating balance in eyes-closed conditions. The MLLE value reflects the overall coordination between multisegment movements. Individuals of different ages can be distinguished by their MLLE values. The standing stability of human is reduced with the increment of age.

  4. The effect of a hybrid assistive limb® on sit-to-stand and standing patterns of stroke patients

    Science.gov (United States)

    Kasai, Rie; Takeda, Sunao

    2016-01-01

    [Purpose] The Hybrid Assistive Limb® (HAL®) robot suit is a powered exoskeleton that can assist a user’s lower limb movement. The purpose of this study was to assess the effectiveness of HAL® in stroke rehabilitation, focusing on the change of the sit-to-stand (STS) movement pattern and standing posture. [Subjects and Methods] Five stroke patients participated in this study. Single leg HAL® was attached to each subject’s paretic lower limb. The subjects performed STS three times both with and without HAL® use. A tri-axial accelerometer was used to assess the STS movement pattern. Forward-tilt angle (FTA) and the time required for STS were measured with and without HAL® use. Surface electromyography (EMG) of STS and standing were recorded to assess the vastus medialis muscle activities of the paretic limb. [Results] The average FTA without HAL® use was 35° and it improved to 43° with HAL® use. The time required for STS was longer for all subjects with HAL® use (without HAL® use: 3.42 s, with HAL® use: 5.11 s). The integrated EMGs of HAL® use compared to those without HAL®, were 83.6% and 66.3% for STS and standing, respectively. [Conclusion] HAL® may be effective in improving STS and standing patterns of stroke patients. PMID:27390416

  5. Residual Liquefaction under Standing Waves

    DEFF Research Database (Denmark)

    Kirca, V.S. Ozgur; Sumer, B. Mutlu; Fredsøe, Jørgen

    2012-01-01

    This paper summarizes the results of an experimental study which deals with the residual liquefaction of seabed under standing waves. It is shown that the seabed liquefaction under standing waves, although qualitatively similar, exhibits features different from that caused by progressive waves....... The experimental results show that the buildup of pore-water pressure and the resulting liquefaction first starts at the nodal section and spreads towards the antinodal section. The number of waves to cause liquefaction at the nodal section appears to be equal to that experienced in progressive waves for the same...

  6. 11kW stand alone wind turbine based on proven wind turbine

    DEFF Research Database (Denmark)

    Bindner, H.; Wodstrup, J.; Andersen, J.

    2004-01-01

    and enable control of frequency and voltage independently on both the grid side and the generator side. The prototype has been installed at Risø. The paper will present results from test runs of the system both operating stand-alone supplying a single load and in parallel operation with a diesel genset....

  7. Allometric Scaling and Resource Limitations Model of Total Aboveground Biomass in Forest Stands: Site-scale Test of Model

    Science.gov (United States)

    CHOI, S.; Shi, Y.; Ni, X.; Simard, M.; Myneni, R. B.

    2013-12-01

    Sparseness in in-situ observations has precluded the spatially explicit and accurate mapping of forest biomass. The need for large-scale maps has raised various approaches implementing conjugations between forest biomass and geospatial predictors such as climate, forest type, soil property, and topography. Despite the improved modeling techniques (e.g., machine learning and spatial statistics), a common limitation is that biophysical mechanisms governing tree growth are neglected in these black-box type models. The absence of a priori knowledge may lead to false interpretation of modeled results or unexplainable shifts in outputs due to the inconsistent training samples or study sites. Here, we present a gray-box approach combining known biophysical processes and geospatial predictors through parametric optimizations (inversion of reference measures). Total aboveground biomass in forest stands is estimated by incorporating the Forest Inventory and Analysis (FIA) and Parameter-elevation Regressions on Independent Slopes Model (PRISM). Two main premises of this research are: (a) The Allometric Scaling and Resource Limitations (ASRL) theory can provide a relationship between tree geometry and local resource availability constrained by environmental conditions; and (b) The zeroth order theory (size-frequency distribution) can expand individual tree allometry into total aboveground biomass at the forest stand level. In addition to the FIA estimates, two reference maps from the National Biomass and Carbon Dataset (NBCD) and U.S. Forest Service (USFS) were produced to evaluate the model. This research focuses on a site-scale test of the biomass model to explore the robustness of predictors, and to potentially improve models using additional geospatial predictors such as climatic variables, vegetation indices, soil properties, and lidar-/radar-derived altimetry products (or existing forest canopy height maps). As results, the optimized ASRL estimates satisfactorily

  8. Status and Plans for a Superconducting RF Accelerator Test Facility at Fermilab

    International Nuclear Information System (INIS)

    Andrews, R.; Baffes, C.M.; Carlson, K.; Chase, B.; Church, M.D.; Harms, E.R.; Klebaner, A.L.; Leibfritz, J.R.; Martinez, A.; Nagaitsev, S.; Nobrega, L.E.

    2012-01-01

    The Advanced Superconducting Test Accelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating a 750 MeV electron beam with ILC beam intensity. An expansion of this facility was recently completed that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. Two new buildings were also constructed adjacent to the ASTA facility to house a new cryogenic plant and multiple superconducting RF (SRF) cryomodule test stands. In addition to testing accelerator components, this facility will be used to test RF power systems, instrumentation, and control systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

  9. Stand structure and regeneration of harvested Araucaria araucana ...

    African Journals Online (AJOL)

    Stand structure and regeneration of harvested Araucaria araucana–Nothofagus stands in central Chile. Rafael M Navarro-Cerrillo, Fernando Olave, Francisco Moreno, Sergio de Miguel, Margarita Clemente ...

  10. Regenerating mixed oak stands in Pennsylvania: a quarter-century retrospective

    Science.gov (United States)

    P. J. Gould; K. C. Steiner; J. C. Finley; M. E. McDill

    2003-01-01

    The outcomes of regeneration treatments in 90 oak-dominated stands in Pennsylvania are examined 20 to 33 years after treatment. Approximately one-quarter of the stands failed to reach 50 percent stocking after at least 20 years, but most stands regenerated successfully. Red maple is the most frequently observed species in the regenerated stands, followed by oak species...

  11. Effects of stand and inter-specific stocking on maximizing standing tree carbon stocks in the eastern United States

    Science.gov (United States)

    Christopher W. Woodall; Anthony W. D' Amato; John B. Bradford; Andrew O. Finley

    2011-01-01

    There is expanding interest in management strategies that maximize forest carbon (C) storage to mitigate increased atmospheric carbon dioxide. The tremendous tree species diversity and range of stand stocking found across the eastern United States presents a challenge for determining optimal combinations for the maximization of standing tree C storage. Using a...

  12. Consistent thermodynamic properties of lipids systems

    DEFF Research Database (Denmark)

    Cunico, Larissa; Ceriani, Roberta; Sarup, Bent

    different pressures, with azeotrope behavior observed. Available thermodynamic consistency tests for TPx data were applied before performing parameter regressions for Wilson, NRTL, UNIQUAC and original UNIFAC models. The relevance of enlarging experimental databank of lipids systems data in order to improve......Physical and thermodynamic properties of pure components and their mixtures are the basic requirement for process design, simulation, and optimization. In the case of lipids, our previous works[1-3] have indicated a lack of experimental data for pure components and also for their mixtures...... the performance of predictive thermodynamic models was confirmed in this work by analyzing the calculated values of original UNIFAC model. For solid-liquid equilibrium (SLE) data, new consistency tests have been developed [2]. Some of the developed tests were based in the quality tests proposed for VLE data...

  13. Where We Now Stand

    Science.gov (United States)

    Lumsden, Keith G.

    1969-01-01

    Noting the acceleration of scientific evaluation, the author focuses his attention on where we now stand in the evaluation of two methods of instruction: programed learning materials and television. (Editor)

  14. I Can Stand Learning: A Controlled Pilot Intervention Study on the Effects of Increased Standing Time on Cognitive Function in Primary School Children

    Directory of Open Access Journals (Sweden)

    Katharina Wick

    2018-02-01

    Full Text Available Sedentarism is considered an independent cardiovascular risk factor. Thus, the present study investigated the effects of employing standing desks in classrooms on cognitive function. The intervention class (IG; n = 19 was supplied with standing desks and balance pads for 11 weeks. The control class (CG; n = 19 received lessons as usual. Standing time was assessed objectively (accelerometers and subjectively (self-report sheets, external classroom observers. The impact of standing on the digit span task and Eriksen flanker task was analysed. The standing time of the IG was higher during the school day in comparison to the CG (lesson: p = 0.004; break: p = 0.003. The intra-class correlation coefficient between self-reports and external observation was high (ICC = 0.94. The IG improved slightly on the Digit Span Task compared to CG. Employing standing desks for at least 1 h per school day serves as a feasible and effective opportunity to improve cognitive function.

  15. Point-of-care-testing of standing posture with Wii balance board and Microsoft Kinect during transcranial direct current stimulation: a feasibility study.

    Science.gov (United States)

    Dutta, Arindam; Chugh, Sanjay; Banerjee, Alakananda; Dutta, Anirban

    2014-01-01

    Non-invasive brain stimulation (NIBS) is a promising tool for facilitating motor function. NIBS therapy in conjunction with training using postural feedback may facilitate physical rehabilitation following posture disorders (e.g., Pusher Syndrome). The objectives of this study were, 1) to develop a low-cost point-of-care-testing (POCT) system for standing posture, 2) to investigate the effects of anodal tDCS on functional reach tasks using the POCT system. Ten community-dwelling elderly (age >50 years) subjects evaluated the POCT system for standing posture during functional reach tasks where their balance score on Berg Balance Scale was compared with that from Center-of-Mass (CoM) - Center-of-Pressure (CoP) posturography. Then, in a single-blind, sham-controlled study, five healthy right-leg dominant subjects (age: 26.4 ± 5.3 yrs) were evaluated using the POCT system under two conditions - with anodal tDCS of primary motor representations of right tibialis anterior muscle and with sham tDCS. The maximum CoP-CoM lean-angle was found to be well correlated with the BBS score in the elderly subjects The anodal tDCS strongly (p = 0.0000) affected the maximum CoP excursions but not the return reaction time in healthy. It was concluded that the CoM-CoP lean-line could be used for posture feedback and monitoring during tDCS therapy in conjunction with balance training exercises.

  16. Stand tending and root rot in Norway spruce stands - economical effects caused by root rot at different thinning regimes

    International Nuclear Information System (INIS)

    Johansson, Mats

    1997-01-01

    This report is divided into three parts: 1) a literature study describing the most common fungi causing rot in wood and descriptions of various strategies to reduce economic loss from root rot, 2) a check of a model describing the development of butt rot in pure Norway spruce plantations in southern Sweden, and 3) simulated economic effects of root rot in stands with various stand tending. The rot model was used to estimate future rot frequencies in the economic calculations. In order to avoid overestimations of rot frequencies, the calculations were also executed when assuming slower growth of rot than shown in the model. When analysing the economical effects of rot, the following three thinning programmes were used: Program 1: thinning at the ages of 30- and 45 years. Final felling at the ages 50-, 55-, 60-, 65-, and 70 years. Program 2: thinning at the ages of 40- and 60- years. Final felling at the ages 65 and 75 years. Program 3: thinning at the ages of 30-, 40-, 55-, and 70 years. Final felling at the ages 80 and 90 years. With an interest rate of 3%, programme 2 (final felling at the age of 65 years) had the highest value at present. This result was valid when presuming butt rot in the stand as well as when presuming no butt rot in the stand. There was a small difference between the value at present in programme 1 (final felling at the age of 60 years) and in programme 3 (final felling at the age of 80 years). When presuming butt rot in the stand, the value at present in programme 3 decreased somewhat more in comparison to the value at present in programme 1. Compared to no butt rot in the stand, the optimal final felling time appeared five to ten years earlier when assuming butt rot in the stand. Stand tending programme 1 and an interest rate of 3% were used. Interest rates 2 and 4% did not indicate shorter rotation. The calculated optimal time of final felling appeared at the same stand age whether assuming rot preset or not. The results in this study

  17. Stand development of trembling aspen in Canaan Valley, West Virginia

    Science.gov (United States)

    James S. Rentch; James T. Anderson

    2008-01-01

    In wetlands of Canaan Valley, West Virginia, trembling aspen occurs as a disjunct population well south of its primary natural range. Based on sample data from 15 stands, we found that aspen occurs as nearly monospecific stands or clones. Eight stands had median ages between 30 and 40 yrs, and we suggest that stand initiation was related to changes in land use after...

  18. Environmental Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Environmental Test Facility (ETF) provides non-isolated shock testing for stand-alone equipment and full size cabinets under MIL-S-901D specifications. The ETF...

  19. Validity and Responsiveness to Change of the 30-Second Chair-Stand Test in Older Adults Admitted to an Emergency Department

    DEFF Research Database (Denmark)

    Hansen Bruun, Inge; Mogensen, Christian B; Nørgaard, Birgitte

    2017-01-01

    BACKGROUND AND PURPOSE: Few physical performance measurement tools are validated for acutely admitted older adults, and for this reason we aimed to examine the validity and responsiveness to change of the 30-second Chair-Stand Test (30s-CST) used to assess physical performance in older adults...... in bathing, dressing, cooking, cleaning, and shopping. Concurrent validity of the 30s-CST compared with the de Morton Mobility Index (DEMMI) on physical performance of acutely admitted older adults was examined with 156 patients. The analysis of concurrent validity included the entire DEMMI and 2 subsets...... of DEMMI: "DEMMI walking" and "DEMMI dynamic balance." The responsiveness to change in the 30s-CST compared with DEMMI was examined with 117 patients. All patients were classified as having either low physical performance (30s-CST ≤8) or high physical performance (30s-CST >8); these groups were used...

  20. SPEED ROLLER STAND MEASUREMENT SYSTEM CHECKING TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Y. Zybtsev

    2011-01-01

    Full Text Available The study has shown that the accuracy of brakes checking by inertial stands depends upon the applied methods of measurement of braking parameters (stand slowing down, braking distance, brakes triggering time, current speed as well as the methods of metrological checking of measuring system canals.

  1. Calculations of mechanisms for balance control during narrow and single-leg standing in fit older adults: A reliability study.

    Science.gov (United States)

    Aberg, A C; Thorstensson, A; Tarassova, O; Halvorsen, K

    2011-07-01

    For older people balance control in standing is critical for performance of activities of daily living without falling. The aims were to investigate reliability of quantification of the usage of the two balance mechanisms M(1) 'moving the centre of pressure' and M(2) 'segment acceleration' and also to compare calculation methods based on a combination of kinetic (K) and kinematic (Km) data, (K-Km), or Km data only concerning M(2). For this purpose nine physically fit persons aged 70-78 years were tested in narrow and single-leg standing. Data were collected by a 7-camera motion capture system and two force plates. Repeated measure ANOVA and Tukey's post hoc tests were used to detect differences between the standing tasks. Reliability was estimated by ICCs, standard error of measurement including its 95% CI, and minimal detectable change, whereas Pearson's correlation coefficient was used to investigate agreement between the two calculation methods. The results indicated that for the tasks investigated, M(1) and M(2) can be measured with acceptable inter- and intrasession reliability, and that both Km and K-Km based calculations may be useful for M(2), although Km data may give slightly lower values. The proportional M(1):M(2) usage was approximately 9:1, in both anterio-posterior (AP) and medio-lateral (ML) directions for narrow standing, and about 2:1 in the AP and of 1:2 in the ML direction in single-leg standing, respectively. In conclusion, the tested measurements and calculations appear to constitute a reliable way of quantifying one important aspect of balance capacity in fit older people. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Minimum joint space width (mJSW) of patellofemoral joint on standing ''skyline'' radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

    Energy Technology Data Exchange (ETDEWEB)

    Simoni, Paolo; Jamali, Sanaa; Alvarez Miezentseva, Victoria [CHU de Liege, Diagnostic Imaging Departement, Domanine du Sart Tilman, Liege (Belgium); Albert, Adelin [CHU de Liege, Biostatistics Departement, Domanine du Sart Tilman, Liege (Belgium); Totterman, Saara; Schreyer, Edward; Tamez-Pena, Jose G. [Qmetrics Technologies, Rochester, NY (United States); Zobel, Bruno Beomonte [Campus Bio-Medico University, Diagnostic Imaging Departement, Rome (Italy); Gillet, Philippe [CHU de Liege, Orthopaedic surgery Department, Domanine du Sart Tilman, Liege (Belgium)

    2013-11-15

    To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing ''skyline'' radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). A couple of standing ''skyline'' radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 {+-} 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Standing ''skyline'' radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements. (orig.)

  3. Harvesting energy wood in connection to young stand treatment; Energiapuun korjuu taimikon harvennuksen yhteydessae

    Energy Technology Data Exchange (ETDEWEB)

    Haemaelaeinen, J; Lilleberg, R; Poikela, A; Rieppo, K [Metsaeteho Oy, Helsinki (Finland)

    1997-12-01

    In the study felling-bunching and the Chipset chipharvester was tried in late thinning of a young stand. Also the impact of energy wood recovery in the young stand stage on the profitability of first thinning was monitored. On the study site the amount of trees to be cut was 5 300 - 22 000 trees/ha, mean height 2,7 - 5,0 m and the total biomass amounted to 26 - 75 m{sup 3}/ha. The felling-bunching was made with a chain-saw equipped with felling handles. The work consisted of opening of the strip roads, of thinning the stand between strip roads and of bunching the trees for the chip-harvester. The effective time expenditure of felling-bunching was on the different sites 8,5 - 27 in/ha or 0,24 - 0,64 h/m{sup 3}. The calculated costs of the work were 900 - 2 800 FIM/ha or 26 - 67 FIM/m{sup 3}. The density and volume of the trees strongly influenced work productivity. The Chipset chipping productivity was 5,7 - 8,7 m{sup 3} per gross effective hour. The chipping costs, when hauling distance was 250 meters, were 44 - 81 FIM/m{sup 3} or 21 - 43 FIM/MVVh. The total costs of energy wood procurement at the plant were 112 - 144 FIM/m{sup 3} or 56 - 73 FIM/MWh. The opening of strip roads during young stand treatment decreases net volume later in the first thinning. According to calculations made for the example sites the net volume decreased by approx. 9 m{sup 3}/ha. The first thinning costs thus increased by 4 FIM/m{sup 3} or ca 5 %. In the extension project the technical, economical and productional preconditions for combining young stand treatment, energy wood harvesting and first thinning will be monitored

  4. Heart rate variability in the standing position reflects training adaptation in professional soccer players.

    Science.gov (United States)

    Ravé, Guillaume; Fortrat, Jacques-Olivier

    2016-08-01

    To show that heart rate variability (HRV) in the standing position better reflects the way in which athletes adapt to training in so-called intermittent sports than the indicator of resting parasympathetic tone usually employed in endurance sports. Twenty professional soccer players (intermittent sport) took part in a 5-week training session divided into three successive periods: "Warm-up", "Intensive training" and "Tapering". At the beginning and end of each of the three periods, a stand test was carried out and the heart rate was recorded, beat by beat (Polar Team 2). We analysed HRV to determine the indicator mostly used to demonstrate training adaptation in endurance sports (lnRMSSD supine, natural logarithm of root mean square of the successive differences) as well as indicators obtained by means of spectral analysis in both supine and standing position. A decrease in heart rate was observed in the supine position at rest during training (-5.2 ± 1.3 bpm) while lnRMSSD and spectral analysis indicators remained unchanged. The "Warm-up" caused an increase in spectral analysis total power in standing position which was further highlighted by "Tapering" (3.39 ± 0.09, 3.61 ± 0.08 and 3.65 ± 0.09 log ms(2), respectively). However, the autonomic changes are probably more complex than a change in autonomic activity or balance since spectral analysis autonomic indicators remained unchanged. HRV in the standing position could monitor training adaptation in intermittent sports contrary to the indicator usually employed in endurance sports. However, the significance of the HRV change in the standing position during training remains unclear.

  5. General approach to the testing of binary solubility systems for thermodynamic consistency. Consolidated Fuel Reprocessing Program

    International Nuclear Information System (INIS)

    Hamm, L.L.; Van Brunt, V.

    1982-08-01

    A comparison of implicit Runge-Kutta and orthogonal collocation methods is made for the numerical solution to the ordinary differential equation which describes the high-pressure vapor-liquid equilibria of a binary system. The systems of interest are limited to binary solubility systems where one of the components is supercritical and exists as a noncondensable gas in the pure state. Of the two methods - implicit Runge-Kuta and orthogonal collocation - this paper attempts to present some preliminary but not necessarily conclusive results that the implicit Runge-Kutta method is superior for the solution to the ordinary differential equation utilized in the thermodynamic consistency testing of binary solubility systems. Due to the extreme nonlinearity of thermodynamic properties in the region near the critical locus, an extended cubic spline fitting technique is devised for correlating the P-x data. The least-squares criterion is employed in smoothing the experimental data. Even though the derivation is presented specifically for the correlation of P-x data, the technique could easily be applied to any thermodynamic data by changing the endpoint requirements. The volumetric behavior of the systems must be given or predicted in order to perform thermodynamic consistency tests. A general procedure is developed for predicting the volumetric behavior required and some indication as to the expected limit of accuracy is given

  6. Culture, cross-role consistency, and adjustment: testing trait and cultural psychology perspectives.

    Science.gov (United States)

    Church, A Timothy; Anderson-Harumi, Cheryl A; del Prado, Alicia M; Curtis, Guy J; Tanaka-Matsumi, Junko; Valdez Medina, José L; Mastor, Khairul A; White, Fiona A; Miramontes, Lilia A; Katigbak, Marcia S

    2008-09-01

    Trait and cultural psychology perspectives on cross-role consistency and its relation to adjustment were examined in 2 individualistic cultures, the United States (N=231) and Australia (N=195), and 4 collectivistic cultures, Mexico (N=199), the Philippines (N=195), Malaysia (N=217), and Japan (N=180). Cross-role consistency in trait ratings was evident in all cultures, supporting trait perspectives. Cultural comparisons of mean consistency provided support for cultural psychology perspectives as applied to East Asian cultures (i.e., Japan) but not collectivistic cultures more generally. Some but not all of the hypothesized predictors of consistency were supported across cultures. Cross-role consistency predicted aspects of adjustment in all cultures, but prediction was most reliable in the U.S. sample and weakest in the Japanese sample. Alternative constructs proposed by cultural psychologists--personality coherence, social appraisal, and relationship harmony--predicted adjustment in all cultures but were not, as hypothesized, better predictors of adjustment in collectivistic cultures than in individualistic cultures.

  7. Dose-dependent pheromone responses of mountain pine beetle in stands of lodgepole pine

    Science.gov (United States)

    Daniel R. Miller; B. Staffan Lindgren; John H. Borden

    2005-01-01

    We conducted seven behavioral choice tests with Lindgren multiple-funnel traps in stands of mature lodgepole pine in British Columbia, from 1988 to 1994, to determine the dosedependent responses of the mountain pine beetle, Dendroctonus ponderosae Hopkins, to its pheromones. Amultifunctional dose-dependent response was exhibited by D. ...

  8. Standing wave acoustic levitation on an annular plate

    Science.gov (United States)

    Kandemir, Mehmet Hakan; Çalışkan, Mehmet

    2016-11-01

    In standing wave acoustic levitation technique, a standing wave is formed between a source and a reflector. Particles can be attracted towards pressure nodes in standing waves owing to a spring action through which particles can be suspended in air. This operation can be performed on continuous structures as well as in several numbers of axes. In this study an annular acoustic levitation arrangement is introduced. Design features of the arrangement are discussed in detail. Bending modes of the annular plate, known as the most efficient sound generation mechanism in such structures, are focused on. Several types of bending modes of the plate are simulated and evaluated by computer simulations. Waveguides are designed to amplify waves coming from sources of excitation, that are, transducers. With the right positioning of the reflector plate, standing waves are formed in the space between the annular vibrating plate and the reflector plate. Radiation forces are also predicted. It is demonstrated that small particles can be suspended in air at pressure nodes of the standing wave corresponding to a particular bending mode.

  9. Recent advances in standing equine orthopedic surgery.

    Science.gov (United States)

    O'Brien, Thomas; Hunt, Robert J

    2014-04-01

    In all surgeries with the patient standing under chemical and physical restraint, patient compliance is of the utmost importance. All fractures of the third metacarpal or metatarsal condyles and sagittal fracture of the first phalanx are not amenable to internal fixation with the horse standing, and young unhandled horses may not have a suitable disposition for standing surgical treatment of septic pedal osteitis, or implantation and removal of transphyseal screws. Previous operator experience in performing the procedure or technique under general anesthesia is beneficial. Appreciation of appropriate topographic anatomic landmarks is important, and intraoperative radiographic control is useful. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Availability of periodically tested systems

    International Nuclear Information System (INIS)

    Signoret, J.P.

    1979-01-01

    There is at the present time a need in accurate models to asess the availability of periodically tested stand-by systems. This paper shows how to improve the well known 'saw-tooth curve' model in order to take into account various reliability parameters. A model is developed to assess the pointwise and the mean availabilities of periodically tested stand-by systems. Exact and approxination formulae are given. In addition, the model developed herein leads to optimize the test interval in order to minimize the mean unavailability. A safety diesel in a nuclear power plant is given as an example

  11. Culture, Cross-Role Consistency, and Adjustment: Testing Trait and Cultural Psychology Perspectives

    OpenAIRE

    Church, A. Timothy; Anderson-Harumi, Cheryl A.; del Prado, Alicia M.; Curtis, Guy J.; Tanaka-Matsumi, Junko; Valdez Medina, José L.; Mastor, Khairul A.; White, Fiona A.; Miramontes, Lilia A.; Katigbak, Marcia S.

    2008-01-01

    Trait and cultural psychology perspectives on cross-role consistency and its relation to adjustment were examined in two individualistic cultures, the United States (N = 231) and Australia (N = 195), and four collectivistic cultures, Mexico (N = 199), Philippines (N = 195), Malaysia (N = 217), and Japan (N = 180). Cross-role consistency in trait ratings was evident in all cultures, supporting trait perspectives. Cultural comparisons of mean consistency provided support for cultural psychology...

  12. Standing Stability in Knee Osteoarthritis Patients

    Directory of Open Access Journals (Sweden)

    M.T. Karimi

    2016-09-01

    Full Text Available Aims: Being prevalent in the more than 40 years old persons, the knee osteoarthritis is one of the main factors in the function system failure mainly affecting their life. There is a type of instability in the persons with knee osteoarthritis, which is an increase in the domain and frequency of body pressure center. The aim of the present study was to compare the standing stability parameters in persons with knee osteoarthritis and healthy persons. Instrument & Methods: In this case-control, 15 patients with knee osteoarthritis referred to the physiotherapy clinic of the rehabilitation center and Al-Zahra hospital were studied in the muscle-skeletal research center of Isfahan University of Medical Sciences in 2015. The subjects were selected via stratified sampling method. As control group, 15 healthy persons were also studied in Isfahan. Total path length and the domain and frequency of pressure center in different directions were measured to assess the stability. Data was analyzed by SPSS 19 software using descriptive statistics and paired T test. Findings: There were increases in the mean movement domain and the frequency of pressure center in the anterior-posterior and the internal-external directions, as well as in the total path proceeded by the pressure center in the internal-external direction, in the persons with knee osteoarthritis than the healthy persons (p0.05. Conclusion: Standing stability and balance in persons with knee osteoarthritis decreases compared to healthy persons.

  13. Quantifying the Lateral Bracing Provided by Standing Steam Roof Systems

    OpenAIRE

    Sorensen, Taylor J.

    2016-01-01

    One of the major challenges of engineering is finding the proper balance between economical and safe. Currently engineers at Nucor Corporation have ignored the additional lateral bracing provided by standing seam roofing systems to joists because of the lack of methods available to quantify the amount of bracing provided. Based on the results of testing performed herein, this bracing is significant, potentially resulting in excessively conservative designs and unnecessary costs. This proje...

  14. Free-Standing Organic Transistors and Circuits with Sub-Micron Thicknesses

    Science.gov (United States)

    Fukuda, Kenjiro; Sekine, Tomohito; Shiwaku, Rei; Morimoto, Takuya; Kumaki, Daisuke; Tokito, Shizuo

    2016-01-01

    The realization of wearable electronic devices with extremely thin and flexible form factors has been a major technological challenge. While substrates typically limit the thickness of thin-film electronic devices, they are usually necessary for their fabrication and functionality. Here we report on ultra-thin organic transistors and integrated circuits using device components whose substrates that have been removed. The fabricated organic circuits with total device thicknesses down to 350 nm have electrical performance levels close to those fabricated on conventional flexible substrates. Moreover, they exhibit excellent mechanical robustness, whereby their static and dynamic electrical characteristics do not change even under 50% compressive strain. Tests using systematically applied compressive strains reveal that these free-standing organic transistors possess anisotropic mechanical stability, and a strain model for a multilayer stack can be used to describe the strain in this sort of ultra-thin device. These results show the feasibility of ultimate-thin organic electronic devices using free-standing constructions. PMID:27278828

  15. An analytical model of stand dynamics as a function of tree growth, mortality and recruitment: the shade tolerance-stand structure hypothesis revisited.

    Science.gov (United States)

    Zavala, Miguel A; Angulo, Oscar; Bravo de la Parra, Rafael; López-Marcos, Juan C

    2007-02-07

    Light competition and interspecific differences in shade tolerance are considered key determinants of forest stand structure and dynamics. Specifically two main stand diameter distribution types as a function of shade tolerance have been proposed based on empirical observations. All-aged stands of shade tolerant species tend to have steeply descending, monotonic diameter distributions (inverse J-shaped curves). Shade intolerant species in contrast typically exhibit normal (unimodal) tree diameter distributions due to high mortality rates of smaller suppressed trees. In this study we explore the generality of this hypothesis which implies a causal relationship between light competition or shade tolerance and stand structure. For this purpose we formulate a partial differential equation system of stand dynamics as a function of individual tree growth, recruitment and mortality which allows us to explore possible individual-based mechanisms--e.g. light competition-underlying observed patterns of stand structure--e.g. unimodal or inverse J-shaped equilibrium diameter curves. We find that contrary to expectations interspecific differences in growth patterns can result alone in any of the two diameter distributions types observed in the field. In particular, slow growing species can present unimodal equilibrium curves even in the absence of light competition. Moreover, light competition and shade intolerance evaluated both at the tree growth and mortality stages did not have a significant impact on stand structure that tended to converge systematically towards an inverse J-shaped curves for most tree growth scenarios. Realistic transient stand dynamics for even aged stands of shade intolerant species (unimodal curves) were only obtained when recruitment was completely suppressed, providing further evidence on the critical role played by juvenile stages of tree development (e.g. the sampling stage) on final forest structure and composition. The results also point out the

  16. Stand model for upland forests of Southern Arkansas

    Energy Technology Data Exchange (ETDEWEB)

    Mielke, D.L.; Shugart, H.H.; West, D.C.

    1978-06-01

    A forest stand growth and composition simulator (FORAR) was developed by modifying a stand growth model by Shugart and West (1977). FORAR is a functional stand model which used ecological parameters to relate individual tree growth to environment rather than using Markov probability matrices or differential equations to determine single tree or species replacement rates. FORAR simulated tree growth and species composition of upland forests of Union County, Ark., by considering 33 tree species on a /sup 1///sub 12/ ha circular plot.

  17. Comparative shoulder kinematics during free standing, standing depression lifts and daily functional activities in persons with paraplegia: considerations for shoulder health.

    Science.gov (United States)

    Riek, L M; Ludewig, P M; Nawoczenski, D A

    2008-05-01

    Case series; nonparametric repeated-measures analysis of variance. To compare and contrast three-dimensional shoulder kinematics during frequently utilized upper extremity weight-bearing activities (standing depression lifts used in brace walking, weight-relief raises, transfers) and postures (sitting rest, standing in a frame) in spinal cord injury (SCI). Movement Analysis Laboratory, Department of Physical Therapy, Ithaca College, Rochester, NY, USA. Three female and two male subjects (39.2+/-6.1 years old) at least 12 months post-SCI (14.6+/-6.7 years old), SCI distal to T2 and with an ASIA score of A. The Flock of Birds magnetic tracking device was used to measure three-dimensional positions of the scapula, humerus and thorax during various activities. Standing in a frame resulted in significantly less scapular anterior tilt (AT) and greater glenohumeral external rotation (GHER) than standing depression lifts and weight-relief raises. Standing frame posture offers the most favorable shoulder joint positions (less scapular AT and greater GHER) when compared to sitting rest posture, weight-relief raises, transfers and standing depression lifts. Knowledge of kinematic patterns associated with each activity is an essential first step to understanding the potential impact on shoulder health. Choosing specific activities or modifying techniques within functional activities that promote favorable shoulder positions may preserve long-term shoulder health.

  18. Plant distribution and stand characteristics in brackish marshes: Unravelling the roles of abiotic factors and interspecific competition

    Science.gov (United States)

    Carus, Jana; Heuner, Maike; Paul, Maike; Schröder, Boris

    2017-09-01

    Due to increasing pressure on estuarine marshes from sea level rise and river training, there is a growing need to understand how species-environment relationships influence the zonation and growth of tidal marsh vegetation. In the present study, we investigated the distribution and stand characteristics of the two key brackish marsh species Bolboschoenus maritimus and Phragmites australis in the Elbe estuary together with several abiotic habitat factors. We then tested the effect of these habitat factors on plant growth and zonation with generalised linear models (GLMs). Our study provides detailed information on the importance of single habitat factors and their interactions for controlling the distribution patterns and stand characteristics of two key marsh species. Our results suggest that flow velocity is the main factor influencing species distribution and stand characteristics and together with soil-water salinity even affects the inundation tolerance of the two specie investigated here. Additionally, inundation height and duration as well as interspecific competition helped explain the distribution patterns and stand characteristics. By identifying the drivers of marsh zonation and stand characteristics and quantifying their effects, this study provides useful information for evaluating a future contribution of tidal marsh vegetation to ecosystem-based shore protection.

  19. Tropical forest biomass estimation from truncated stand tables.

    Science.gov (United States)

    A. J. R. Gillespie; S. Brown; A. E. Lugo

    1992-01-01

    Total aboveground forest biomass may be estimated through a variety of techniques based on commercial inventory stand and stock tables. Stand and stock tables from tropical countries commonly omit trees bellow a certain commercial limit.

  20. Information Technology & Applications Corporation v. United States: An Interested Party's "Substantial Chance" at APA Standing

    National Research Council Canada - National Science Library

    Slicker, Christina

    2003-01-01

    ... of government contracts. The purpose of this paper is not to prove with mathematical certainty that the standing result would be identical whether a court applied the Federal Circuit's "interested party" standard or the APA two-prong test...

  1. Consistency argued students of fluid

    Science.gov (United States)

    Viyanti; Cari; Suparmi; Winarti; Slamet Budiarti, Indah; Handika, Jeffry; Widyastuti, Fatma

    2017-01-01

    Problem solving for physics concepts through consistency arguments can improve thinking skills of students and it is an important thing in science. The study aims to assess the consistency of the material Fluid student argmentation. The population of this study are College students PGRI Madiun, UIN Sunan Kalijaga Yogyakarta and Lampung University. Samples using cluster random sampling, 145 samples obtained by the number of students. The study used a descriptive survey method. Data obtained through multiple-choice test and interview reasoned. Problem fluid modified from [9] and [1]. The results of the study gained an average consistency argmentation for the right consistency, consistency is wrong, and inconsistent respectively 4.85%; 29.93%; and 65.23%. Data from the study have an impact on the lack of understanding of the fluid material which is ideally in full consistency argued affect the expansion of understanding of the concept. The results of the study as a reference in making improvements in future studies is to obtain a positive change in the consistency of argumentations.

  2. A contribution to the validation of the Wii Balance Board for the assessment of standing balance.

    Science.gov (United States)

    Pavan, Piero; Cardaioli, Matteo; Ferri, Ilaria; Gobbi, Erica; Carraro, Attilio

    2015-01-01

    Valid and reliable accessible measures of balance are required in a health-related fitness test battery, both in the general population and in groups with special needs. For this purpose, the capability of the Wii Balance Board (WBB) in evaluating standing balance was analysed and compared with a laboratory-graded force platform (FP). A 30-s double limb standing test with open and closed eyes was performed by 28 individuals (12 male and 16 female, mean age = 23.8, SD = ±2.7 years). A simple method of acquisition of the centre of pressure (CoP) over time was applied to compare WBB and FP simultaneously on the same signal. User-defined software was developed to obtain the CoP from WBB over time and the resulting related measures and graphical representations. The comparison of measures, such as sway path and maximum oscillations along the anterior-posterior and medial-lateral direction, obtained with the FP and the WBB shows that the latter, in conjunction with the user-defined developed software, can be appropriate, considering prescribed limits, and an easy-to-use tool for evaluating standing balance.

  3. A Stand-Class Growth and Yield Model for Mexico’s Northern Temperate, Mixed and Multiaged Forests

    Directory of Open Access Journals (Sweden)

    José Návar

    2014-12-01

    Full Text Available The aim of this research was to develop a stand-class growth and yield model based on the diameter growth dynamics of Pinus spp. and Quercus spp. of Mexico’s mixed temperate forests. Using a total of 2663 temporary, circular-sampling plots of 1000 m2 each, nine Weibull distribution techniques of parameter estimation were fitted to the diameter structures of pines and oaks. Statistical equations using stand attributes and the first three moments of the diameter distribution predicted and recovered the Weibull parameters. Using nearly 1200 and 100 harvested trees for pines and oaks, respectively, I developed the total height versus diameter at breast height relationship by fitting three non-linear functions. The Newnham model predicted stem taper and numerical integration was done to estimate merchantable timber volume for all trees in the stand for each diameter class. The independence of the diameter structures of pines and oaks was tested by regressing the Weibull parameters and projecting diameter structures. The model predicts diameter distributions transition from exponential (J inverse, logarithmic to well-balanced distributions with increasing mean stand diameter at breast height. Pine diameter distributions transition faster and the model predicts independent growth rates between pines and oaks. The stand-class growth and yield model must be completed with the diameter-age relationship for oaks in order to carry a full optimization procedure to find stand density and genera composition to maximize forest growth.

  4. The distribution of lumbar intervertebral angles in upright standing and extension is related to low back pain developed during standing.

    Science.gov (United States)

    Viggiani, Daniel; Gallagher, Kaitlin M; Sehl, Michael; Callaghan, Jack P

    2017-11-01

    Lumbar lordosis measures are poorly related to clinical low back pain, however using a controlled exposure such as prolonged standing to identify pain groups may clarify this relationship. The purpose of this study was to determine the distribution of lumbar intervertebral angles in asymptomatic persons who do (pain developers) and do not (non-pain developers) develop low back pain during standing. Sagittal plane lumbar spine radiographs of eight pain developers and eight non-pain developers were taken in three poses: upright standing, full extension and full flexion. Measures of vertebral end plate orientations from L1 to S1 were taken in each pose to compute: intervertebral angles, contribution of each level to the total curve, total lordosis, ranges of motion, relative pose positioning within the range of motion, vertebral shape, and lumbar spine recurve. Measures were compared between pain groups and lumbar levels. Pain group differences in intervertebral angles and level contributions were greatest in the full extension pose, with pain developers having greater contributions from higher lumbar levels and fewer contributions from lower levels than non-pain developers. Pain group differences in intervertebral angle distributions were less pronounced in upright standing and non-existent in full flexion. No other measures differentiated pain groups. Although participants had similar gross-lumbar spine curvature characteristics, non-pain developers have more curvature at lower levels in upright standing and full extension. These differences in regional vertebral kinematics may partially be responsible for standing-induced low back pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The Sit & Stand chair. A revolutionary advance in adaptive seating systems.

    Science.gov (United States)

    Galumbeck, Michael H; Buschbacher, Ralph M; Wilder, Robert P; Winters, Kathryne L; Hudson, Mary Anne; Edlich, Richard F

    2004-01-01

    A major factor governing independence for the elderly and persons with disabilities is the ability to stand from a chair. Factors such as pain, reduced joint range of motion, stiffness, and muscle weakness frequently limit the ability to stand. Sit-to-stand position is even further reduced in patients whose hands and shoulders are afflicted with rheumatoid arthritis. When achieving a sit-to-stand position in the elderly and persons with disabilities, there is considerable risk of the individual falling and sustaining bone fracture. The purposes of this scientific report are to achieve the following goals: (1) to provide a narrative discussion of the senior author's contributions to furniture manufacturing as well as his successful patent application for the SIT & STAND chair, (2) to describe the steps involved in the development of the SIT & STAND prototype, and (3) to examine the performance of the SIT & STAND chair in assisting the elderly or persons with disabilities in achieving a sit-to-stand position. The invention of the SIT & STAND chair by the senior author, Michael Galumbeck, was a culmination of his lifelong interest in adaptive seating systems. His electrically operated chair has the unique ability to assist the occupant to achieve safely a sit-to-stand position. The rear portion of his chair remains in a fixed position to support the buttocks of the user during mechanical lift. The front portion of the seat folds down incrementally as the chair rises to allow the feet of the user to be positioned in a more posterior position firmly on the floor. Using its actuator, the height that the chair rises will vary with the length of the legs of the occupant. Using the drawing program Solid Works (Solid Works, Concord, Massachusetts), drawings of the chair were made. To visualize the operation and performance of the chair, separate drawings were made in the lateral position. The prototype of the SIT & STAND chair was manufactured with an electric actuator that

  6. Penerapan Analisis Diskriminan dalam Pembedaan Kelas Umur Tegakan Pinus (Discriminant Analysist for Stand Class Age Distinction of Pine Stand

    Directory of Open Access Journals (Sweden)

    Priyanto .

    2011-01-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;} This  study  describes the use of discriminant anylisis for pine (Pinus spp. stand class age distinction.    Aim of this  study were (1 to arrange stand age class based on variable of aerial photograph by non hierarchy cluster analysis,  and (2 to find out aerial  photograph variable contribute to stand age class distinction by discriminant analysis.    Data used in study was taken from  a  research  conducted by Adi (1998.   Pinus stand was located  in KPH Bandung Utara, West Java. The variable of aerial photograph that used in this analysis were tone, shape, texture, topography, pattern, crown, diameter and height. The result showed that validation analysis of discriminant function was significant.  Therefore, this function was applicable for grouping new object to stand age class based on discriminant score. Keywords: cluster analysis, discriminat analysis, stand age class, discriminant score

  7. Jumping Stand Apparatus Reveals Rapidly Specific Age-Related Cognitive Impairments in Mouse Lemur Primates.

    Directory of Open Access Journals (Sweden)

    Jean-Luc Picq

    Full Text Available The mouse lemur (Microcebus murinus is a promising primate model for investigating normal and pathological cerebral aging. The locomotor behavior of this arboreal primate is characterized by jumps to and from trunks and branches. Many reports indicate insufficient adaptation of the mouse lemur to experimental devices used to evaluate its cognition, which is an impediment to the efficient use of this animal in research. In order to develop cognitive testing methods appropriate to the behavioral and biological traits of this species, we adapted the Lashley jumping stand apparatus, initially designed for rats, to the mouse lemur. We used this jumping stand apparatus to compare performances of young (n = 12 and aged (n = 8 adults in acquisition and long-term retention of visual discriminations. All mouse lemurs completed the tasks and only 25 trials, on average, were needed to master the first discrimination problem with no age-related differences. A month later, all mouse lemurs made progress for acquiring the second discrimination problem but only the young group reached immediately the criterion in the retention test of the first discrimination problem. This study shows that the jumping stand apparatus allows rapid and efficient evaluation of cognition in mouse lemurs and demonstrates that about half of the old mouse lemurs display a specific deficit in long-term retention but not in acquisition of visual discrimination.

  8. Evaluation of sedation for standing clinical procedures in horses using detomidine combined with buprenorphine.

    Science.gov (United States)

    Taylor, Polly; Coumbe, Karen; Henson, Frances; Scott, David; Taylor, Alan

    2014-01-01

    To examine the effect of including buprenorphine with detomidine for sedation of horses undergoing clinical procedures. Partially blinded, randomised, prospective clinical field trial. Eighty four client-owned horses scheduled for minor surgery or diagnostic investigation under standing sedation. The effects of buprenorphine (5 μg kg(-1) ) (Group B, n = 46) or placebo (5% glucose solution) (Group C, n = 38) in combination with detomidine (10 μg kg(-1) ) were compared in standing horses undergoing minor clinical procedures. The primary outcome measure was successful completion of the procedure. The degree of sedation and ataxia were scored using simple descriptive scales. Heart and respiratory rates were recorded at 15-30 minute intervals. Parametric data from each group were compared using anova or t-test and non parametric data using the Mann-Whitney U test. The procedure was carried out successfully in 91% of Group B and 63% of Group C (p detomidine, increased after buprenorphine but not glucose administration, was more profound in group B and lasted longer (60 versus 30 minutes) p detomidine 10 and 20 μg kg(-1) with minor side effects similar to other alpha2 agonist/opioid combinations. Detomidine-buprenorphine sedation is suitable for standing procedures in horses. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  9. An electromechanical material testing system for in situ electron microscopy and applications.

    Science.gov (United States)

    Zhu, Yong; Espinosa, Horacio D

    2005-10-11

    We report the development of a material testing system for in situ electron microscopy (EM) mechanical testing of nanostructures. The testing system consists of an actuator and a load sensor fabricated by means of surface micromachining. This previously undescribed nanoscale material testing system makes possible continuous observation of the specimen deformation and failure with subnanometer resolution, while simultaneously measuring the applied load electronically with nanonewton resolution. This achievement was made possible by the integration of electromechanical and thermomechanical components based on microelectromechanical system technology. The system capabilities are demonstrated by the in situ EM testing of free-standing polysilicon films, metallic nanowires, and carbon nanotubes. In particular, a previously undescribed real-time instrumented in situ transmission EM observation of carbon nanotubes failure under tensile load is presented here.

  10. Development of Flexible, Free-Standing, Thin Films for Additive Manufacturing and Localized Energy Generation

    Science.gov (United States)

    2015-08-10

    does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. Texas Technical University Box 41035 349...upon reaction. All films were cast at a thickness of 1 mm with constant volume percent solids to ensure consistent rheological properties. The films...2005); 10.1063/1.2058175 Local dynamic mechanical properties in model free-standing polymer thin films J. Chem. Phys. 122, 144712 (2005); 10.1063

  11. Free-Standing, Flexible, Superomniphobic Films.

    Science.gov (United States)

    Vahabi, Hamed; Wang, Wei; Movafaghi, Sanli; Kota, Arun K

    2016-08-31

    Fabrication of most superomniphobic surfaces requires complex process conditions or specialized and expensive equipment or skilled personnel. In order to circumvent these issues and make them end-user-friendly, we developed the free-standing, flexible, superomniphobic films. These films can be stored and delivered to the end-users, who can readily attach them to virtually any surface (even irregular shapes) and impart superomniphobicity. The hierarchical structure, the re-entrant texture, and the low solid surface energy render our films superomniphobic for a wide variety of liquids. We demonstrate that our free-standing, flexible, superomniphobic films have applications in enhanced chemical resistance and enhanced weight bearing.

  12. Acoustic evaluation of wood quality in standing trees. Part I, Acoustic wave behavior

    Science.gov (United States)

    Xiping Wang; Robert J. Ross; Peter Carter

    2007-01-01

    Acoustic wave velocities in standing trees or live softwood species were measured by the time-of-flight (TOF) method. Tree velocities were compared with acoustic velocities measured in corresponding butt logs through a resonance acoustic method. The experimental data showed a skewed relationship between tree and log acoustic measurements. For most trees tested,...

  13. Thrust Stand for Vertically Oriented Electric Propulsion Performance Evaluation

    Science.gov (United States)

    Moeller, Trevor; Polzin, Kurt A.

    2010-01-01

    A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally-stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A non-contact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational restoring force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN-level thrusts, while those tests conducted on 200 lbm thruster yielded a resolution of roughly 2.5 micro at thrust levels of 0.5 N and greater.

  14. Thrust stand for vertically oriented electric propulsion performance evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Trevor [University of Tennessee Space Institute, Tullahoma, Tennessee 37388 (United States); Polzin, Kurt A. [NASA, Marshall Space Flight Center, Huntsville, Alabama 35812 (United States)

    2010-11-15

    A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A noncontact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy-current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN level thrusts, while those tests conducted on a 200 lbm thruster yielded a resolution of roughly 2.5 mN at thrust levels of 0.5 N and greater.

  15. Thrust stand for vertically oriented electric propulsion performance evaluation

    International Nuclear Information System (INIS)

    Moeller, Trevor; Polzin, Kurt A.

    2010-01-01

    A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A noncontact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy-current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN level thrusts, while those tests conducted on a 200 lbm thruster yielded a resolution of roughly 2.5 mN at thrust levels of 0.5 N and greater.

  16. Communicating through humour: A project of stand-up comedy about science.

    Science.gov (United States)

    Pinto, Bruno; Marçal, David; Vaz, Sofia G

    2015-10-01

    A study of a project on science stand-up comedy developed in Portugal between 2009 and 2013 is presented, in which thirteen scientists, coordinated by a science communicator and a professional actor, created and presented comedy acts. Eleven of these scientists were asked about their motivations to participate, the process of performance development and the perceived value of the project. Personal motivations were highly important, but professional reasons were also mentioned. Working in a group with the guidance of coordinators, testing and re-writing the texts and gradually gaining confidence on stage were considered fundamental in the development of the shows. Additionally, a questionnaire revealed that the audience, most of whom were young adults, and held a higher education degree, were satisfied with the show. Overall, both participating scientists and audience members considered that stand-up comedy has potential for science communication. © The Author(s) 2013.

  17. A novel intrinsically porous separator for self-standing lithium-ion batteries

    International Nuclear Information System (INIS)

    Prosini, Pier Paolo; Villano, Paola; Carewska, Maria

    2002-01-01

    γ-LiAlO 2 , Al 2 O 3 and MgO were used as fillers in a PVdF-HFP polymer matrix to form self-standing, intrinsically porous separators for lithium-ion batteries. These separators can be hot-laminated onto the electrodes without losing their ability to adsorb liquid electrolyte. The electrochemical stability of the separators was tested by constructing half-cells with the configuration: Li/fibre-glass/filler-based separator/electrode. MgO-based separators were found to work well with both positive and negative electrodes. An ionic conductivity of about 4x10 -4 S cm -1 was calculated for the MgO-based separator containing 40% 1 M solution of LiPF 6 in an EC/DMC 1:1 solvent. Self-standing, lithium-ion cells were constructed using the MgO-based separator and the resulting battery performance evaluated in terms of cyclability, power and energy density

  18. Stand-alone version of the 11kW Gaia wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Bindner, H.; Rosas, P.A.C.; Teodorescu, R.; Blaabjerg, F.

    2004-09-15

    This report describes the development of a stand-alone version of the 11kW Gaia wind turbine. Various possible configurations are investigated and a configuration using a back-to-back converter is chosen. A model is developed for controller design of the fast controllers of the unit. Controllers are designed and a prototype is built for testing. The report documents the performance of the prototype through measurements done on the full scale prototype installed in a test facility where it has been tested both as a standalone unit and in parallel with a diesel genset. For system wide power quality assessment and controller design a dynamic performance assessment model has been developed. (au)

  19. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Segal, Neil A. [University of Kansas Medical Center, Department of Rehabilitation Medicine, 3901 Rainbow Boulevard, Mailstop 1046, Kansas City, KS (United States); The University of Iowa, Iowa City, IA (United States); Bergin, John; Kern, Andrew; Findlay, Christian [The University of Iowa, Iowa City, IA (United States); Anderson, Donald D. [The University of Iowa, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States)

    2017-02-15

    To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging. This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m{sup 2}; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20 fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW <10 mm. The summary measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility. The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds. The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA. (orig.)

  20. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner

    International Nuclear Information System (INIS)

    Segal, Neil A.; Bergin, John; Kern, Andrew; Findlay, Christian; Anderson, Donald D.

    2017-01-01

    To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging. This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m 2 ; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20 fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW <10 mm. The summary measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility. The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds. The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA. (orig.)