WorldWideScience

Sample records for test results results

  1. CCTF CORE I test results

    International Nuclear Information System (INIS)

    Murao, Yoshio; Sudoh, Takashi; Akimoto, Hajime; Iguchi, Tadashi; Sugimoto, Jun; Fujiki, Kazuo; Hirano, Kenmei

    1982-07-01

    This report presents the results of the following CCTF CORE I tests conducted in FY. 1980. (1) Multi-dimensional effect test, (2) Evaluation model test, (3) FLECHT coupling test. On the first test, one-dimensional treatment of the core thermohydrodynamics was discussed. On the second and third tests, the test results were compared with the results calculated by the evaluation model codes and the results of the corresponding FLECHT-SET test (Run 2714B), respectively. The work was performed under contracts with the Atomic Energy Bureau of Science and Technology Agency of Japan. (author)

  2. Summary of CCTF test results

    International Nuclear Information System (INIS)

    Iguchi, T.; Murao, Y.; Sugimoto, J.; Akimoto, H.; Okubo, T.; Hojo, T.

    1987-01-01

    Conservatism of current safety analysis was assessed by comparing the predicted result with cylindrical core test facility (CCTF) test result performed at Japan Atomic Energy Research Institute. WREM code was selected for the assessment. The overall conservatism of the WREM code on the peak clad temperature prediction was confirmed against CCTF evaluation model (EM) test which simulated the typical initial and boundary conditions in the safety evaluation analysis. WREM code predicted the reasonable core boundary conditions and the conservatism of the code came mainly from core calculation. The conservatism of the WREM code against CCTF data could be attributed to the following three points: (1) no horizontal mixing assumption between subchannels at each elevation; (2) no modeling on heat transfer enhancement caused by the radial core power profile; and (3) conservative heat transfer correlations in the code

  3. Test results of HTTR control system

    International Nuclear Information System (INIS)

    Motegi, Toshihiro; Iigaki, Kazuhiko; Saito, Kenji; Sawahata, Hiroaki; Hirato, Yoji; Kondo, Makoto; Shibutani, Hideki; Ogawa, Satoru; Shinozaki, Masayuki; Mizushima, Toshihiko; Kawasaki, Kozo

    2006-06-01

    The plant control performance of the IHX helium flow rate control system, the PPWC helium flow rate control system, the secondary helium flow rate control system, the inlet temperature control system, the reactor power control system and the outlet temperature control system of the HTTR are obtained through function tests and power-up tests. As the test results, the control systems show stable control response under transient condition. Both of inlet temperature control system and reactor power control system shows stable operation from 30% to 100%, respectively. This report describes the outline of control systems and test results. (author)

  4. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  5. Engineering model cryocooler test results

    International Nuclear Information System (INIS)

    Skimko, M.A.; Stacy, W.D.; McCormick, J.A.

    1992-01-01

    This paper reports that recent testing of diaphragm-defined, Stirling-cycle machines and components has demonstrated cooling performance potential, validated the design code, and confirmed several critical operating characteristics. A breadboard cryocooler was rebuilt and tested from cryogenic to near-ambient cold end temperatures. There was a significant increase in capacity at cryogenic temperatures and the performance results compared will with code predictions at all temperatures. Further testing on a breadboard diaphragm compressor validated the calculated requirement for a minimum axial clearance between diaphragms and mating heads

  6. 688,112 statistical results: Content mining psychology articles for statistical test results

    OpenAIRE

    Hartgerink, C.H.J.

    2016-01-01

    In this data deposit, I describe a dataset that is the result of content mining 167,318 published articles for statistical test results reported according to the standards prescribed by the American Psychological Association (APA). Articles published by the APA, Springer, Sage, and Taylor & Francis were included (mining from Wiley and Elsevier was actively blocked). As a result of this content mining, 688,112 results from 50,845 articles were extracted. In order to provide a comprehensive set...

  7. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  8. 688,112 statistical results : Content mining psychology articles for statistical test results

    NARCIS (Netherlands)

    Hartgerink, C.H.J.

    2016-01-01

    In this data deposit, I describe a dataset that is the result of content mining 167,318 published articles for statistical test results reported according to the standards prescribed by the American Psychological Association (APA). Articles published by the APA, Springer, Sage, and Taylor & Francis

  9. Test Results of PBMR Fuel Spheres

    International Nuclear Information System (INIS)

    Koshcheev, Konstantin; Diakov, Alexander; Beltyukov, Igor; Barybin, Andrey; Chernetsov, Mikhail

    2014-01-01

    Results of pre-irradiation testing of fuel spheres (FS) and coated particles (CP) manufactured by PBMR SOC (Republic of South Africa) are described. The stable high quality level of major characteristics (dimensions, CP coating structure, uranium-235 contamination of the FS matrix graphite and the outer PyC layer of the CP coating) are shown. Results of a methodical irradiation test of two FS in helium and neon medium at temperatures of 800 to 1300 °C with simultaneous determination of release-to-birth ratios for major gaseous fission products (GFP) are described. (author)

  10. Climax granite test results

    Energy Technology Data Exchange (ETDEWEB)

    Ramspott, L.D.

    1980-01-15

    The Lawrence Livermore Laboratory (LLL), as part of the Nevada Nuclear Waste Storage Investigations (NNWSI) program, is carrying out in situ rock mechanics testing in the Climax granitic stock at the Nevada Test Site (NTS). This summary addresses only those field data taken to date that address thermomechanical modeling for a hard-rock repository. The results to be discussed include thermal measurements in a heater test that was conducted from October 1977 through July 1978, and stress and displacement measurements made during and after excavation of the canister storage drift for the Spent Fuel Test (SFT) in the Climax granite. Associated laboratory and field measurements are summarized. The rock temperature for a given applied heat load at a point in time and space can be adequately modeled with simple analytic calculations involving superposition and integration of numerous point source solutions. The input, for locations beyond about a meter from the source, can be a constant thermal conductivity and diffusivity. The value of thermal conductivity required to match the field data is as much as 25% different from laboratory-measured values. Therefore, unless we come to understand the mechanisms for this difference, a simple in situ test will be required to obtain a value for final repository design. Some sensitivity calculations have shown that the temperature field is about ten times more sensitive to conductivity than to diffusivity under the test conditions. The orthogonal array was designed to detect anisotropy. After considering all error sources, anisotropic efforts in the thermal field were less than 5 to 10%.

  11. Relationship between ultrasonic pulse velocity test result and ...

    African Journals Online (AJOL)

    Ultrasonic Pulse Velocity test result showed an inverse relationship (of -0.935) with the crushed concrete compressive strength. Correlation test, multiple regression analysis, graphs and visual inspection were used to analyze the results. The conclusion drawn is that there exists a relationship between UPV test results and ...

  12. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    Science.gov (United States)

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  13. Legal provisions governing the acknowledgment of test results

    International Nuclear Information System (INIS)

    Strecker, A.

    1982-01-01

    The legal provisions governing the acknowledgment of test results are most frequently applied by administrative orders (design and qualification approvals or specimen testing and approval) and are thus claimable and voidable in accordance with general administrative law. The acknowledgment of test certificates requires a legal basis. Test results, however, can be acknowledged also by administrative bodies. Recently, the Federal Government began to delegate more of its legal authority in this field to private institutions, allowing test results to be acknowledged and test certificates to be issued by government controlled private institutions. (orig.) [de

  14. Results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Luk, V.K.; Ludwigsen, J.S.; Hessheimer, M.F.; Komine, Kuniaki; Matsumoto, Tomoyuki; Costello, J.F.

    1998-05-01

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the US Nuclear Regulatory Commission. Two tests are being conducted: (1) a test of a model of a steel containment vessel (SCV) and (2) a test of a model of a prestressed concrete containment vessel (PCCV). This paper summarizes the conduct of the high pressure pneumatic test of the SCV model and the results of that test. Results of this test are summarized and are compared with pretest predictions performed by the sponsoring organizations and others who participated in a blind pretest prediction effort. Questions raised by this comparison are identified and plans for posttest analysis are discussed

  15. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  16. Superconducting solenoid model magnet test results

    International Nuclear Information System (INIS)

    Carcagno, R.; Dimarco, J.; Feher, S.; Ginsburg, C.M.; Hess, C.; Kashikhin, V.V.; Orris, D.F.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.A.; Terechkine, I.; Tompkins, J.C.; Wokas, T.; Fermilab

    2006-01-01

    Superconducting solenoid magnets suitable for the room temperature front end of the Fermilab High Intensity Neutrino Source (formerly known as Proton Driver), an 8 GeV superconducting H- linac, have been designed and fabricated at Fermilab, and tested in the Fermilab Magnet Test Facility. We report here results of studies on the first model magnets in this program, including the mechanical properties during fabrication and testing in liquid helium at 4.2 K, quench performance, and magnetic field measurements. We also describe new test facility systems and instrumentation that have been developed to accomplish these tests

  17. Superconducting solenoid model magnet test results

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Dimarco, J.; Feher, S.; Ginsburg, C.M.; Hess, C.; Kashikhin, V.V.; Orris, D.F.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.A.; Terechkine, I.; /Fermilab

    2006-08-01

    Superconducting solenoid magnets suitable for the room temperature front end of the Fermilab High Intensity Neutrino Source (formerly known as Proton Driver), an 8 GeV superconducting H- linac, have been designed and fabricated at Fermilab, and tested in the Fermilab Magnet Test Facility. We report here results of studies on the first model magnets in this program, including the mechanical properties during fabrication and testing in liquid helium at 4.2 K, quench performance, and magnetic field measurements. We also describe new test facility systems and instrumentation that have been developed to accomplish these tests.

  18. Irradiation effects test Series Scoping Test 1: test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.

    1977-09-01

    The report describes the results of the first scoping test in the Irradiation Effects Test Series conducted by the Thermal Fuels Behavior Program, which is part of the Water Reactor Research Program of EG and G Idaho, Inc. The research is sponsored by the United States Nuclear Regulatory Commission. This test used an unirradiated, three-foot-long, PWR-type fuel rod. The objective of this test was to thoroughly evaluate the remote fabrication procedures to be used for irradiated rods in future tests, handling plans, and reactor operations. Additionally, selected fuel behavior data were obtained. The fuel rod was subjected to a series of preconditioning power cycles followed by a power increase which brought the fuel rod power to about 20.4 kW/ft peak linear heat rating at a coolant mass flux of 1.83 x 10 6 lb/hr-ft 2 . Film boiling occurred for a period of 4.8 minutes following flow reductions to 9.6 x 10 5 and 7.5 x 10 5 lb/hr-ft 2 . The test fuel rod failed following reactor shutdown as a result of heavy internal and external cladding oxidation and embrittlement which occurred during the film boiling operation

  19. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Georgeton, G.K.; Poirier, M.R.

    1990-01-01

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  20. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  1. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test acknow...... acknowledgement. Rather, the physicians, trans-ferred work practices from their own departments, which did not have electronic white-boards, to the ED. This finding suggests a challenge to the cross-disciplinary work and norms for how to follow up on blood-test results in the ED....

  2. Results of interlaboratory tests regarding TXRF

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von

    2000-01-01

    Interlaboratory or intercomparison tests can be performed for proficiency testing of individual laboratories, for the certification of a special sample material and for the validation of a certain method. We participated in two interlaboratory tests in order to validate total reflection x-ray fluorescence analysis (TXRF). We used our results to evaluate TXRF and to compare it with other competing methods, particularly with respect of precision and accuracy. The first interlaboratory test was organized by IAEA (International Atomic Energy Agency, Vienna, Austria). As a candidate for reference material, a lichen (IAEA-336 Lichen) was distributed among 27 participants. In our laboratory, the powdered biogenic material was digested with nitric acid under high pressure and analyzed by TXRF. - The second interlaboratory test was organized by IRMM (Institute for Reference Materials and Measurements, Geel, Belgium). As a certified test sample with undisclosed values, a sediment (IMEP-14) was delivered to 220 laboratories. We digested the geogenic material again by nitric acid and additionally by hydrofluoric acid and analyzed it by TXRF. - In both test samples, six or eight different trace elements, respectively, were determined by TXRF with a content between 2 and 2000 mg/kg. Calibration was carried out by internal standardization. For that purpose, Ga or Se, respectively, was added as standard element. The measurement uncertainty of TXRF was estimated by the method of error propagation. In our paper we will report on the results of the two interlaboratory tests. It will be shown that TXRF is highly reliable for a correct determination of trace elements in biogenic and geogenic samples. It is competitive with the established methods of trace analyses which were involved in these tests and it is even superior to them in certain aspects. (author)

  3. Irradiation Effects Test Series: Test IE-2. Test results report

    International Nuclear Information System (INIS)

    Allison, C.M.; Croucher, D.W.; Ploger, S.A.; Mehner, A.S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m 2 . After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m 2 , the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m 2 caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations

  4. Reproducibility of the results in ultrasonic testing

    International Nuclear Information System (INIS)

    Chalaye, M.; Launay, J.P.; Thomas, A.

    1980-12-01

    This memorandum reports on the conclusions of the tests carried out in order to evaluate the reproducibility of ultrasonic tests made on welded joints. FRAMATOME have started a study to assess the dispersion of results afforded by the test line and to characterize its behaviour. The tests covered sensors and ultrasonic generators said to be identical to each other (same commercial batch) [fr

  5. Evaluation of ring tensile test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Anantharaman, S.; Balakrishnan, K.S.; Sivaramakrish, K.S.

    1990-01-01

    Ring specimens of 5-mm width cut from Zircaloy-2 cladding of reactor operated fuel elements that had experienced 5000 to 15,000 MWD/T of fuel burnup were subjected to ring tensile testing. The true stress-true strain data points up to the onset of necking from the individual load-elongation curves of these specimens were used as input data in Voce's equation. The results reveal that the uniform elongation (UE) values generated using Voce's equation were within (UE-2)% of the experimental percent uniform elongation (UE%). The corresponding ultimate tensile strength values were within ±1%. The uncertainty inherently associated in the determination of gauge length introduces extraneous deformation in the rings tested. Previous results had shown that a 14% increase in cladding diameter caused the gauge length to increase by 40%. To simulate the contribution of extraneous deformation due to an increase in cladding diameter, an analysis of the variation of the tensile parameters (uniform elongation and ultimate tensile strength) due to increase in the gauge length in the range of 10 to 40% was carried out. The results are discussed

  6. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  7. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  8. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2013-05-29

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and

  9. School results and access test results as indicators of first-year performance at university

    Directory of Open Access Journals (Sweden)

    A Bothma

    2004-06-01

    Full Text Available The goals set by the National Plan for Higher Education, the fact that many schools are still severely disadvantaged as well as far-reaching changes in the school system demand that South African universities urgently reconsider their admission procedures. Redesigning admission procedures calls for a thorough understanding of the interrelationships between school marks, results in existing access tests and first-year university performance. These interrelationships were statistically investigated in the case of the 1999, 2000 and 2001 intake groups, who were compelled to write access tests before being admitted to Stellenbosch University. The results of this investigation confirm an alarming degree of unpreparedness among many prospective students regarding what is expected of them at university. This is aggravated by school marks creating a totally unrealistic expectation of performance in the first year at university. It is emphasised that schools and authorities dealing with admission of prospective students at universities should be cognisant of the findings reported here. Furthermore, the statistical analyses demonstrate several novel techniques for investigating the interrelationship between school marks, access test results and university performance.

  10. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2012-11-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  11. Mobile evaporator corrosion test results

    International Nuclear Information System (INIS)

    Rozeveld, A.; Chamberlain, D.B.

    1997-05-01

    Laboratory corrosion tests were conducted on eight candidates to select a durable and cost-effective alloy for use in mobile evaporators to process radioactive waste solutions. Based on an extensive literature survey of corrosion data, three stainless steel alloys (304L, 316L, AL-6XN), four nickel-based alloys (825, 625, 690, G-30), and titanium were selected for testing. The corrosion tests included vapor phase, liquid junction (interface), liquid immersion, and crevice corrosion tests on plain and welded samples of candidate materials. Tests were conducted at 80 degrees C for 45 days in two different test solutions: a nitric acid solution. to simulate evaporator conditions during the processing of the cesium ion-exchange eluant and a highly alkaline sodium hydroxide solution to simulate the composition of Tank 241-AW-101 during evaporation. All of the alloys exhibited excellent corrosion resistance in the alkaline test solution. Corrosion rates were very low and localized corrosion was not observed. Results from the nitric acid tests showed that only 316L stainless steel did not meet our performance criteria. The 316L welded interface and crevice specimens had rates of 22.2 mpy and 21.8 mpy, respectively, which exceeds the maximum corrosion rate of 20 mpy. The other welded samples had about the same corrosion resistance as the plain samples. None of the welded samples showed preferential weld or heat-affected zone (HAZ) attack. Vapor corrosion was negligible for all alloys. All of the alloys except 316L exhibited either open-quotes satisfactoryclose quotes (2-20 mpy) or open-quotes excellentclose quotes (<2 mpy) corrosion resistance as defined by National Association of Corrosion Engineers. However, many of the alloys experienced intergranular corrosion in the nitric acid test solution, which could indicate a susceptibility to stress corrosion cracking (SCC) in this environment

  12. EFTF cobalt test assembly results

    International Nuclear Information System (INIS)

    Rawlins, J.A.; Wootan, D.W.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1988-01-01

    A cobalt test assembly containing yttrium hydride pins for neutron moderation was irradiated in the Fast Flux Test Facility during Cycle 9A for 137.7 equivalent full power days at a power level fo 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal to produce Co-60, and a set of 4 pins with europium oxide to produce Gd-153, a radioisotope used in detection of the bone disease Osteoporosis. Post-irradiation examination of the cobalt pins determined the Co-60 produced with an accuracy of about 5 %. The measured Co-60 spatially distributed concentrations were within 20 % of the calculated concentrations. The assembly average Co-60 measured activity was 4 % less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes Eu-152 and Eu-154 to an absolute accuracy of about 10 %. The measured europium radioisotpe anc Gd-153 concentrations were within 20 % of calculated values. In conclusion, the hydride assembly performed well and is an excellent vehicle for many Fast Flux Test Facility isotope production applications. The results also demonstrate that the calculational methods developed by the Westinghouse Hanford Company are very accurate. (author)

  13. Evaluating the RELM Test Results

    Directory of Open Access Journals (Sweden)

    Michael K. Sachs

    2012-01-01

    Full Text Available We consider implications of the Regional Earthquake Likelihood Models (RELM test results with regard to earthquake forecasting. Prospective forecasts were solicited for M≥4.95 earthquakes in California during the period 2006–2010. During this period 31 earthquakes occurred in the test region with M≥4.95. We consider five forecasts that were submitted for the test. We compare the forecasts utilizing forecast verification methodology developed in the atmospheric sciences, specifically for tornadoes. We utilize a “skill score” based on the forecast scores λfi of occurrence of the test earthquakes. A perfect forecast would have λfi=1, and a random (no skill forecast would have λfi=2.86×10-3. The best forecasts (largest value of λfi for the 31 earthquakes had values of λfi=1.24×10-1 to λfi=5.49×10-3. The best mean forecast for all earthquakes was λ̅f=2.84×10-2. The best forecasts are about an order of magnitude better than random forecasts. We discuss the earthquakes, the forecasts, and alternative methods of evaluation of the performance of RELM forecasts. We also discuss the relative merits of alarm-based versus probability-based forecasts.

  14. Large-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Bontha, Jagannadha R.; Daniel, Richard C.; Kurath, Dean E.; Adkins, Harold E.; Billing, Justin M.; Burns, Carolyn A.; Davis, James M.; Enderlin, Carl W.; Fischer, Christopher M.; Jenks, Jeromy WJ; Lukins, Craig D.; MacFarlan, Paul J.; Shutthanandan, Janani I.; Smith, Dennese M.

    2012-12-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  15. Ball Aerospace SBMD Coating Test Results

    Science.gov (United States)

    Brown, Robert; Lightsey, Paul; Russell, J. Kevin (Technical Monitor)

    2002-01-01

    The Sub-scale Beryllium Mirror Demonstrator that was successfully tested to demonstrate cryogenic figuring of a bare mirror has been coated with a protected gold reflective surface and retested at cryogenic temperatures. Results showing less than 9 nm rms surface distortion attributable to the added coating are presented.

  16. Analysis of SCTF/CCTF counterpart test results

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Sobajima, Makoto; Iwamura, Takamichi; Ohnuki, Akira; Abe, Yutaka; Adachi, Hiromichi; Murao, Yoshio

    1990-06-01

    Slab Core Test Facility (SCTF) and Cylindrical Core Test Facility (CCTF) are large scale experimental facilities of Japan Atomic Energy Research Institute (JAERI) for the investigation of reflooding behavior during a postulated loss-of-coolant accident (LOCA) in PWRs. Although the flow area scaling ratios of both facilities to a 1,000 MWe class PWR are the same and 1/21.4, the SCTF has the same core width as the radius of the reference PWR while the CCTF has a 1/4.5 times shorter core radius. Therefore, a few SCTF/CCTF counterpart tests were conducted in order to investigate the difference in core reflooding behavior between in the SCTF and CCTF tests as well as the effect of core radial length on core two-dimensional thermo-hydrodynamic behavior. This report present the test results and an analysis on them. Major results obtained are: (1) Taking account of the differences in test conditions and facility design, core reflooding behavior is considered to be similar between the SCTF and the CCTF test. Main difference of the facility design is in the effective core flow area and this is considered to result in the difference in core water accumulation behavior. (2) The effect of core radial length on core two-dimensional thermo-hydrodynamic behavior has been observed to be significant and heat transfer enhancement or degradation in radial direction is more significant for the longer radius core. (3) In addition, where the core power varies significantly in the radial direction, significant heat transfer enhancement has been observed in the higher power bundle during the LPCI period. Also, in the peripheral region, heat transfer degradation has been observed more significantly in the outer bundle even they have the same bundle power. (4) Magnitude of these heat transfer enhancement or degradation was larger at the higher elevation than the midplane level in the SCTF test, whereas smaller in the CCTF test. (author)

  17. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  18. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  19. ALICE TRD results from prototype tests

    CERN Document Server

    Andronic, A; Blume, C; Braun-Munzinger, P; Bucher, D; Catanescu, G; Ciobanu, M; Daues, H W; Devismes, A; Finck, C; Herrmann, N; Lister, T A; Mahmoud, Tariq; Peitzmann, Thomas; Petrovici, M; Reygers, K; Santo, R; Schicker, R; Sedykha, S; Simon, R S; Stachel, J; Stelzer, H; Wessels, J P; Winkelmann, O; Windelband, B; Xu, C

    2002-01-01

    We present results from tests of a prototype of the TRD for the ALICE experiment at LHC. We investigate the performance-of different radiator types, composed of foils, fibres and foams. The pion rejection performance for different methods of analysis over a momentum range from 0.7 to 2 GeV/c is presented. (8 refs).

  20. Production LHC HTS power lead test results

    CERN Document Server

    Tartaglia, M; Fehér, S; Huang, Y; Orris, D F; Pischalnikov, Y; Rabehl, Roger Jon; Sylvester, C D; Zbasnik, J

    2005-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under "standard" and "extreme" operating conditions, and the stability of performance across thermal cycles.

  1. Production LHC HTS power lead test results

    International Nuclear Information System (INIS)

    Tartaglia, M.A.; Carcagno, R.H.; Feher, S.; Huang, Y.; Orris, D.F.; Pischalnikov, Y.; Rabehl, R.J.; Sylvester, C.; Zbasnik, J.

    2004-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under ''standard'' and ''extreme'' operating conditions, and the stability of performance across thermal cycles

  2. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the...

  3. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  4. Boeing's STAR-FODB test results

    Science.gov (United States)

    Fritz, Martin E.; de la Chapelle, Michael; Van Ausdal, Arthur W.

    1995-05-01

    Boeing has successfully concluded a 2 1/2 year, two phase developmental contract for the STAR-Fiber Optic Data Bus (FODB) that is intended for future space-based applications. The first phase included system analysis, trade studies, behavior modeling, and architecture and protocal selection. During this phase we selected AS4074 Linear Token Passing Bus (LTPB) protocol operating at 200 Mbps, along with the passive, star-coupled fiber media. The second phase involved design, build, integration, and performance and environmental test of brassboard hardware. The resulting brassboard hardware successfully passed performance testing, providing 200 Mbps operation with a 32 X 32 star-coupled medium. This hardware is suitable for a spaceflight experiment to validate ground testing and analysis and to demonstrate performace in the intended environment. The fiber bus interface unit (FBIU) is a multichip module containing transceiver, protocol, and data formatting chips, buffer memory, and a station management controller. The FBIU has been designed for low power, high reliability, and radiation tolerance. Nine FBIUs were built and integrated with the fiber optic physical layer consisting of the fiber cable plant (FCP) and star coupler assembly (SCA). Performance and environmental testing, including radiation exposure, was performed on selected FBIUs and the physical layer. The integrated system was demonstrated with a full motion color video image transfer across the bus while simultaneously performing utility functions with a fiber bus control module (FBCM) over a telemetry and control (T&C) bus, in this case AS1773.

  5. Uprated OMS Engine Status-Sea Level Testing Results

    Science.gov (United States)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  6. Irradiation Effects Test Series: Test IE-3. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, L. C.; Allison, C. M.; Croucher, D. W.; Ploger, S. A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m/sup 2/. After a flow reduction to 2120 kg/s-m/sup 2/, film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions.

  7. RSG Deployment Case Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Owsley, Stanley L.; Dodson, Michael G.; Hatchell, Brian K.; Seim, Thomas A.; Alexander, David L.; Hawthorne, Woodrow T.

    2005-09-01

    The RSG deployment case design is centered on taking the RSG system and producing a transport case that houses the RSG in a safe and controlled manner for transport. The transport case was driven by two conflicting constraints, first that the case be as light as possible, and second that it meet a stringent list of Military Specified requirements. The design team worked to extract every bit of weight from the design while striving to meet the rigorous Mil-Spec constraints. In the end compromises were made primarily on the specification side to control the overall weight of the transport case. This report outlines the case testing results.

  8. The PANDA facility and first test results

    International Nuclear Information System (INIS)

    Dreier, J.; Huggenberger, M.; Aubert, C.; Bandurski, T.; Fischer, O.; Healzer, J.; Lomperski, S.; Strassberger, H.J.; Varadi, G.; Yadigaroglu, G.

    1996-01-01

    The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport patterns. (orig.) [de

  9. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  10. A Fuzzy Logic Based Method for Analysing Test Results

    Directory of Open Access Journals (Sweden)

    Le Xuan Vinh

    2017-11-01

    Full Text Available Network operators must perform many tasks to ensure smooth operation of the network, such as planning, monitoring, etc. Among those tasks, regular testing of network performance, network errors and troubleshooting is very important. Meaningful test results will allow the operators to evaluate network performanceof any shortcomings and to better plan for network upgrade. Due to the diverse and mainly unquantifiable nature of network testing results, there is a needs to develop a method for systematically and rigorously analysing these results. In this paper, we present STAM (System Test-result Analysis Method which employs a bottom-up hierarchical processing approach using Fuzzy logic. STAM is capable of combining all test results into a quantitative description of the network performance in terms of network stability, the significance of various network erros, performance of each function blocks within the network. The validity of this method has been successfully demonstrated in assisting the testing of a VoIP system at the Research Instiute of Post and Telecoms in Vietnam. The paper is organized as follows. The first section gives an overview of fuzzy logic theory the concepts of which will be used in the development of STAM. The next section describes STAM. The last section, demonstrating STAM’s capability, presents a success story in which STAM is successfully applied.

  11. BWR Full Integral Simulation Test (FIST). Phase I test results

    International Nuclear Information System (INIS)

    Hwang, W.S.; Alamgir, M.; Sutherland, W.A.

    1984-09-01

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report

  12. SULTAN test facility: Summary of recent results

    International Nuclear Information System (INIS)

    Stepanov, Boris; Bruzzone, Pierluigi; Sedlak, Kamil; Croari, Giancarlo

    2013-01-01

    The test campaigns of the ITER conductors in the SULTAN test facility re-started in December 2011 after three months break. The main focus of the activities is about the qualification tests of the Central Solenoid (CS) conductors, with three different samples for a total six variations of strand suppliers and cable layouts. In 2012, five Toroidal Field (TF) conductor samples have also been tested as part of the supplier and process qualification phase of the European, Korean, Chinese and Russian Federation Agencies. A summary of the test results for all the ITER samples tested in the last period is presented, including an updated statistics of the broad transition, the performance degradation and the impact of layout variations. The role of SULTAN test facility during the ITER construction is reviewed, and the load of work for the next three years is anticipated

  13. Results from the CLIC Test Facility

    CERN Document Server

    Braun, H; Bossart, Rudolf; Chautard, F; Corsini, R; Delahaye, J P; Godot, J C; Hutchins, S; Kamber, I; Madsen, J H B; Rinolfi, Louis; Rossat, G; Schreiber, S; Suberlucq, Guy; Thorndahl, L; Wilson, Ian H; Wuensch, Walter

    1996-01-01

    In order to study the principle of the Compact Linear Collider (CLIC) based on the Two Beam Acceleration (TBA) scheme at high frequency, a CLIC Test Facility (CTF) has been set-up at CERN. After four years of successful running, the experimental programme is now fully completed and all its objectives reached, particularly the generation of a high intensity drive beam with short bunches by a photo-injector, the production of 30 GHz RF power and the acceleration of a probe beam by 30 GHz structures. A summary of the CTF results and their impact on linear collider design is given. This covers 30 GHz high power testing, study of intense, short single bunches; as well as RF-Gun, photocathode and beam diagnostic developments. A second phase of the test facility (CTF2) is presently being installed to demonstrate the feasibility of the TBA scheme by constructing a fully engineered, 10 m long, test section very similar to the CLIC drive and main linacs, producing up to 480 MW of peak RF power at 30 GHz and acceleratin...

  14. Early results of gate valve flow interruption blowdown tests

    International Nuclear Information System (INIS)

    DeWall, K.G.

    1988-01-01

    The preliminary results of the USNRC/INEL high-energy BWR line break flow interruption testing are presented. Two representative nuclear valve assemblies were cycled under design basis Reactor Water Cleanup pipe break conditions to provide input for the technical basis for resolving the Nuclear Regulatory Commission's Generic Issue 87. The effects of the blowdown hydraulic loadings on valve operability, especially valve closure stem forces, were studied. The blowdown tests showed that, given enough thrust, typical gate valves will close against the high flow resulting from a line break. The tests also showed that proper operator sizing depends on the correct identification of values for the sizing equation. Evidence exists that values used in the past may not be conservative for all valve applications. The tests showed that improper operator lock ring installation following test or maintenance can invalidate in-situ test results and prevent the valve from performing its design function. 2 refs., 12 figs., 2 tabs

  15. Field Lysimeter Investigations - test results: Low-Level Waste Data Base Development Program: Test results for fiscal years 1994-1995

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Rodgers, R.D.; Hilton, L.D.; Neilson, R.M. Jr.

    1996-06-01

    The Field Lysimeter Investigations: Low-Level Waste Data Base Development Program, funded by the U.S. Nuclear Regulatory Commission (NRC), is (1) studying the degradation effects in EPICOR-II organic ion-exchange resins caused by radiation, (2) examining the adequacy of test procedures recommended in the Branch Technical Position on Waste Form to meet the requirements of 10 CFR 61 using solidified EPICOR-II resins, (3) obtaining performance information on solidified EPICOR-II ion-exchange resins in a disposal environment, and (4) determining the condition of EPICOR-II liners. Results of the final 2 (10 total) years of data acquisition from operation of the field testing are presented and discussed. During the continuing field testing, both portland type I-II cement and Dow vinyl ester-styrene waste forms are being tested in lysimeter arrays located at Argonne National Laboratory-East in Illinois and at Oak Ridge National Laboratory. The experimental equipment is described and results of waste form characterization using tests recommended by the NRC's open-quotes Technical Position on Waste Formclose quotes are presented. The study is designed to provide continuous data on nuclide release and movement, as well as environmental conditions, over a 20-year period. At the end of the tenth year, the experiment was closed down. Examination of soil and waste forms is planned to be conducted next and will be reported later

  16. Large-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Gauglitz, Phillip A.; Burns, Carolyn A.; Fountain, Matthew S.; Shimskey, Rick W.; Billing, Justin M.; Bontha, Jagannadha R.; Kurath, Dean E.; Jenks, Jeromy WJ; MacFarlan, Paul J.; Mahoney, Lenna A.

    2013-08-01

    One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used

  17. Test results of the SMES model coil. Pulse performance

    International Nuclear Information System (INIS)

    Hamajima, Takataro; Shimada, Mamoru; Ono, Michitaka

    1998-01-01

    A model coil for superconducting magnetic energy storage (SMES model coil) has been developed to establish the component technologies needed for a small-scale 100 kWh SMES device. The SMES model coil was fabricated, and then performance tests were carried out in 1996. The coil was successfully charged up to around 30 kA and down to zero at the same ramp rate of magnetic field experienced in a 100 kWh SMES device. AC loss in the coil was measured by an enthalpy method as parameters of ramp rate and flat top current. The results were evaluated by an analysis and compared with short-sample test results. The measured hysteresis loss is in good agreement with that estimated from the short-sample results. It was found that the coupling loss of the coil consists of two major coupling time constants. One is a short time constant of about 200 ms, which is in agreement with the test results of a short real conductor. The other is a long time constant of about 30 s, which could not be expected from the short sample test results. (author)

  18. Automated Testing Infrastructure and Result Comparison for Geodynamics Codes

    Science.gov (United States)

    Heien, E. M.; Kellogg, L. H.

    2013-12-01

    The geodynamics community uses a wide variety of codes on a wide variety of both software and hardware platforms to simulate geophysical phenomenon. These codes are generally variants of finite difference or finite element calculations involving Stokes flow or wave propagation. A significant problem is that codes of even low complexity will return different results depending on the platform due to slight differences in hardware, software, compiler, and libraries. Furthermore, changes to the codes during development may affect solutions in unexpected ways such that previously validated results are altered. The Computational Infrastructure for Geodynamics (CIG) is funded by the NSF to enhance the capabilities of the geodynamics community through software development. CIG has recently done extensive work in setting up an automated testing and result validation system based on the BaTLab system developed at the University of Wisconsin, Madison. This system uses 16 variants of Linux and Mac platforms on both 32 and 64-bit processors to test several CIG codes, and has also recently been extended to support testing on the XSEDE TACC (Texas Advanced Computing Center) Stampede cluster. In this work we overview the system design and demonstrate how automated testing and validation occurs and results are reported. We also examine several results from the system from different codes and discuss how changes in compilers and libraries affect the results. Finally we detail some result comparison tools for different types of output (scalar fields, velocity fields, seismogram data), and discuss within what margins different results can be considered equivalent.

  19. Cone Penetrometer N Factor Determination Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2014-03-05

    This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to releate resistance measurements taken with the cone penetrometer to shear strength.

  20. SLD liquid argon calorimeter prototype test results

    International Nuclear Information System (INIS)

    Dubois, R.; Eigen, G.; Au, Y.

    1985-10-01

    The results of the SLD test beam program for the selection of a calorimeter radiator composition within a liquid argon system are described, with emphasis on the study of the use of uranium to obtain equalization of pion and electron responses

  1. Partial-array test results in IFSMTF

    International Nuclear Information System (INIS)

    Lue, J.W.; Dresner, L.; Koizumi, K.; Lubell, M.S.; Luton, J.N.; Shen, S.S.; Zahn, G.R.; Zichy, J.A.

    1985-01-01

    Preliminary performance tests of two large superconducting magnets have been carried out in the International Fusion Superconducting Magnet Test Facility (IFSMTF). Each of the Japanese (JA) and General Dynamics/Convair (GD) coils was operated up to its full design current of 10.2 kA with the other serving as an adjacent background coil at 40% of design current. Cryostatic stability was demonstrated for both coils by noting recovery from a full half-turn (5 m) driven normal. A new pick-up coil compensation scheme was successfully used for the quench detection system. Each coil remained superconducting when the other was dumped. Unique instrumentation was used to measure changes in bore dimensions and displacement of the winding from the coil case. Agreement between structural analysis and measurement of bore dimension changes resulting from magnetic loads is good. The Swiss (CH) coil underwent only a cryogenic test. The forced cooling worked well and an inlet temperature of 3.8 K was demonstrated

  2. Hawaiian Electric Advanced Inverter Test Plan - Result Summary

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Nelson, Austin; Prabakar, Kumaraguru; Nagarajan, Adarsh

    2016-10-14

    This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

  3. Guidelines to Interpret Results of Mechanical Blade Test

    International Nuclear Information System (INIS)

    Arias Vega, F.; Sanz Martin, J. C.

    1999-01-01

    This report shows the interpretation of full scale rotor blade test results and describes the engineering testing models and coefficients for any feasible rotor blade design, in order to accept and to certify any final manufactured blade as an allowable product, fit for use and working with a completely security during all the wind turbines lifetime. This work was carried out at the Wind Energy Division of the CIEMAT.DER and it is based on the authors technical experience in this field, after many years working on testing blades. Also, this paper contains results of the European wind turbine Standards II relevant to the European Project: JOULE III R.D. where the Wind Energy Division took part as participant too. (Author)

  4. Guidelines to Interpret Results of Mechanical Blade Test

    Energy Technology Data Exchange (ETDEWEB)

    Arias Vega, F.; Sanz Martin, J. C. [Ciemat, Madrid (Spain)

    2000-07-01

    This report shows the interpretation of full scale rotor blade test results and describes the engineering testing models and coefficients for any feasible rotor blade design, in order to accept and to certify any final manufactured blades as an allowable product, fit for use and working with a completely security during all the windturbine's lifetime. This work was carried out at the Wind Energy Division of the CIEMAT.DER and it is based on the author's technical experience in this field, after many years working on testing blades. Also, this paper contains results of the European wind turbine Standards II relevant to the European Project: JOULE III R.D. where the Wind Energy Division took part as participant too. (Author)

  5. Reproducibility of the results in nondestructive testing

    International Nuclear Information System (INIS)

    Launay, J.P.; Chalaye, H.; Thomas, A.

    1980-10-01

    Pressure vessels must comply with very severe safety criteria. In order to ensure that the required quality is attained, non destructive tests are used and these have to be highly reliable: magnetoscopy and liquid penetration for surface examinations, radiography and ultrasonics for voluminal examinations. In the case of ultrasonic examinations, a study of parameters has been made and a statistical analysis of the results has made it possible to calculate the dispersion due to the testing equipment [fr

  6. 7 CFR 91.24 - Reports of test results.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Reports of test results. 91.24 Section 91.24 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS...

  7. Evaluation of LLTR series II test A-7 results

    International Nuclear Information System (INIS)

    Knittle, D.E.; Amos, J.C.; Yang, T.M.

    1981-09-01

    This report evaluates the test A-7 data and assesses the capability of the analytical methodology (as a result of Series I program) to predict the thermal/hydraulic phenomena associated with a large SWR event occurring after the sodium system pressure has increased to near the rupture disc burst pressure due to a smaller size leak event. Evaluation of intertest examination data to determine the extent of test article damage resulting from test A-7 is also included

  8. Small-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, G. N.; Mahoney, Lenna A.; Tran, Diana N.; Burns, Carolyn A.; Kurath, Dean E.

    2013-08-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the

  9. Sims Prototype System 2 test results: Engineering analysis

    Science.gov (United States)

    1978-01-01

    The testing, problems encountered, and the results and conclusions obtained from tests performed on the IBM Prototype System, 2, solar hot water system, at the Marshall Space Flight Center Solar Test Facility was described. System 2 is a liquid, non draining solar energy system for supplying domestic hot water to single residences. The system consists of collectors, storage tank, heat exchanger, pumps and associated plumbing and controls.

  10. Preliminary results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Matsumoto, T.; Komine, K.; Arai, S.

    1997-01-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11-12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented

  11. Aerodynamic and Acoustic Flight Test Results and Results for the Stratospheric Observatory for Infrared Astronomy

    Science.gov (United States)

    Cumming, Stephen B.; Smith, Mark S.; Cliatt, Larry J.; Frederick, Michael A.

    2014-01-01

    As part of the Stratospheric Observatory for Infrared Astronomy program, a 747SP airplane was modified to carry a 2.5-m telescope in the aft section of the fuselage. The resulting airborne observatory allows for observations above 99 percent of the water vapor in the atmosphere. The open cavity created by the modifications had the potential to significantly affect the airplane in the areas of aerodynamics and acoustics. Several series of flight tests were conducted to clear the operating envelope of the airplane for astronomical observations, planned to be performed between the altitudes of 35,000 ft and 45,000 ft. The flight tests were successfully completed. Cavity acoustics were below design limits, and the overall acoustic characteristics of the cavity were better than expected. The modification did have some effects on the stability and control of the airplane, but these effects were not significant. Airplane air data systems were not affected by the modifications. This paper describes the methods used to examine the aerodynamics and acoustic data from the flight tests and provides a discussion of the flight-test results in the areas of cavity acoustics, stability and control, and air data.

  12. Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing

    Science.gov (United States)

    Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.

    1990-01-01

    During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.

  13. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  14. Production Facility Prototype Blower 1000 Hour Test Results II

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-08

    Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

  15. Interim results from UO2 fuel oxidation tests in air

    International Nuclear Information System (INIS)

    Campbell, T.K.; Gilbert, E.R.; Thornhill, C.K.; White, G.D.; Piepel, G.F.; Griffin, C.W.j.

    1987-08-01

    An experimental program is being conducted at Pacific Northwest Laboratory (PNL) to extend the characterization of spent fuel oxidation in air. To characterize oxidation behavior of irradiated UO 2 , fuel oxidation tests were performed on declad light-water reactor spent fuel and nonirradited UO 2 pellets in the temperature range of 135 to 250 0 C. These tests were designed to determine the important independent variables that might affect spent fuel oxidation behavior. The data from this program, when combined with the test results from other programs, will be used to develop recommended spent fuel dry-storage temperature limits in air. This report describes interim test results. The initial PNL investigations of nonirradiated and spent fuels identified the important testing variables as temperature, fuel burnup, radiolysis of the air, fuel microstructure, and moisture in the air. Based on these initial results, a more extensive statistically designed test matrix was developed to study the effects of temperature, burnup, and moisture on the oxidation behavior of spent fuel. Oxidation tests were initiated using both boiling-water reactor and pressurized-water reactor fuels from several different reactors with burnups from 8 to 34 GWd/MTU. A 10 5 R/h gamma field was applied to the test ovens to simulate dry storage cask conditions. Nonirradiated fuel was included as a control. This report describes experimental results from the initial tests on both the spent and nonirradiated fuels and results to date on the tests in a 10 5 R/h gamma field. 33 refs., 51 figs., 6 tabs

  16. Relationship between substances in seminal plasma and Acrobeads Test results.

    Science.gov (United States)

    Komori, Kazuhiko; Tsujimura, Akira; Okamoto, Yoshio; Matsuoka, Yasuhiro; Takao, Tetsuya; Miyagawa, Yasushi; Takada, Shingo; Nonomura, Norio; Okuyama, Akihiko

    2009-01-01

    To asses the effects of seminal plasma on sperm function. Retrospective case-control study. University hospital. One hundred fourteen infertile men. Acrobeads Test scores (0-4) and measurement of interleukin (IL)-6, soluble IL-6 receptor, epidermal growth factor, insulin-like growth factor-I (IGF-I), transforming growth factor-beta I, superoxide dismutase, calcitonin, and macrophage migration inhibitory factor (MIF) levels in seminal plasma. Kruskal-Wallis test to compare the concentrations of substances as a nonparametric test for differences among Acrobeads Test scores and a multivariable logistic regression model to find independent risk factors associated with abnormal Acrobeads Test results. The Acrobeads Test score was 0 for 7 samples, 1 for 20 samples, 2 for 18 samples, 3 for 28 samples, and 4 for 41 samples. Age, abstinence period, and semen parameters, except for sperm motility and percentage of sperm with abnormal morphology, had no effect on the Acrobeads Test results. Concentrations of IGF-I and MIF were significantly higher in patients with abnormal Acrobeads Test results. Multivariate analysis indicated that MIF and IGF-I were significantly associated with abnormal Acrobeads Test results (scores 0 to 1). Although further studies are needed, IGF-I and MIF in seminal plasma may have negative effects on sperm function.

  17. Recent results on the RIA test in IGR reactor

    International Nuclear Information System (INIS)

    Asmolov, V.; Yegorova, L.

    1997-01-01

    At the 23d WRSM meeting the data base characterizing results of VVER high burnup fuel rods tests under reactivity-initiated accident (RIA) conditions was presented. Comparison of PWR and VVER failure thresholds was given also. Additional analysis of the obtained results was being carried out during 1996. The results of analysis show that the two different failure mechanisms were observed for PWR and VVER fuel rods. Some factors which can be as the possible reasons of these differences are presented. First of them is the state of preirradiated cladding. Published test data for PWR high burnup fuel rods demonstrated that the PWR high burnup fuel rods failed at the RIA test are characterized by very high level of oxidation and hydriding for the claddings. Corresponding researches were performed at Institute of Atomic Reactors (RLAR, Dimitrovgrad, Russia) for large set of VVER high burnup fuel rods. Results of these investigations show that preirradiated commercial Zr-1%Nb claddings practically keep their initial levels of oxidation and H 2 concentration. Consequently the VVER preirradiated cladding must keep the high level of mechanical properties. The second reason leading to differences between failure mechanisms for two types of high burnup fuel rods can be the test conditions. Now such kind of analysis have been performed by two methods

  18. How do people respond to self-test results? A cross-sectional survey

    Directory of Open Access Journals (Sweden)

    de Vries Nanne K

    2010-10-01

    Full Text Available Abstract Background Self-tests, tests on medical conditions that can be performed by consumers without consulting a doctor first, are frequently used. Nevertheless, there are concerns about the safety of self-testing, as it may delay diagnosis and appropriate treatment in the case of inappropriate use of the test, or false-negative results. It is unclear whether self-tests stimulate appropriate follow-up behaviour. Our aim was to examine the frequency of self-test use, consumers' response to self-test results in terms of their confidence in the result, reassurance by the test result, and follow-up behaviour. Methods A two step cross-sectional survey was designed. A random sample of 6700 Internet users in an existing Internet panel received an online questionnaire on the use of self-tests. Self-tests were defined as tests on body materials, initiated by consumers with the aim to diagnose a disease or risk factor. A second questionnaire on consumers' response to self-test results was sent to the respondents that were identified as a self-tester in the first questionnaire (n = 703. Results 18.1% (799/4416 of the respondents had ever performed a self-test, the most frequently used tests being those for diabetes (5.3%, kidney disease (4.9%, cholesterol (4.5%, urinary tract infection (1.9% and HIV/AIDS and Chlamydia (both 1.6%. A total of 78.1% of the testers with a normal test result and 81.4% of those with an abnormal result reported confidence in this result. Almost all (95.6% of the testers with a normal result felt reassured. After a normal result, 78.1% did not take any further action and 5.8% consulted a doctor. The corresponding figures after an abnormal test result were 9.3% and 72.2%, respectively. Conclusions Respondents who had performed a self-test seemed to base their follow-up behaviour on the result of the test. They had confidence in the test result, and were often reassured by a normal result. After an abnormal result, most self

  19. AOF: standalone test results of GALACSI

    Science.gov (United States)

    La Penna, P.; Aller Carpentier, E.; Argomedo, J.; Arsenault, R.; Conzelmann, R. D.; Delabre, B.; Donaldson, R.; Gago, F.; Gutierrez-Cheetam, P.; Hubin, N.; Jolley, P.; Kiekebusch, M.; Kirchbauer, J. P.; Klein, B.; Kolb, J.; Kuntschner, H.; Le Louarn, M.; Lizon, J.-L.; Madec, P.-Y.; Manescau, A.; Mehrgan, L.; Oberti, S.; Quentin, J.; Sedghi, B.; Ströbele, S.; Suárez Valles, M.; Soenke, C.; Tordo, S.; Vernet, J.

    2016-07-01

    GALACSI is the Adaptive Optics (AO) module that will serve the MUSE Integral Field Spectrograph. In Wide Field Mode it will enhance the collected energy in a 0.2"×0.2" pixel by a factor 2 at 750 nm over a Field of View (FoV) of 1'×1' using the Ground Layer AO (GLAO) technique. In Narrow Field Mode, it will provide a Strehl Ratio of 5% (goal 10%) at 650 nm, but in a smaller FoV (7.5"×7.5" FoV), using Laser Tomography AO (LTAO). Before being ready for shipping to Paranal, the system has gone through an extensive testing phase in Europe, first in standalone mode and then in closed loop with the DSM in Europe. After outlining the technical features of the system, we describe here the first part of that testing phase and the integration with the AOF ASSIST (Adaptive Secondary Setup and Instrument Stimulator) testbench, including a specific adapter for the IRLOS truth sensor. The procedures for the standalone verification of the main system performances are outlined, and the results of the internal functional tests of GALACSI after full integration and alignment on ASSIST are presented.

  20. Laboratory test result interpretation for primary care doctors in South Africa

    Directory of Open Access Journals (Sweden)

    Naadira Vanker

    2017-03-01

    Full Text Available Background: Challenges and uncertainties with test result interpretation can lead to diagnostic errors. Primary care doctors are at a higher risk than specialists of making these errors, due to the range in complexity and severity of conditions that they encounter. Objectives: This study aimed to investigate the challenges that primary care doctors face with test result interpretation, and to identify potential countermeasures to address these. Methods: A survey was sent out to 7800 primary care doctors in South Africa. Questionnaire themes included doctors’ uncertainty with interpreting test results, mechanisms used to overcome this uncertainty, challenges with appropriate result interpretation, and perceived solutions for interpreting results. Results: Of the 552 responses received, the prevalence of challenges with result interpretation was estimated in an average of 17% of diagnostic encounters. The most commonly-reported challenges were not receiving test results in a timely manner (51% of respondents and previous results not being easily available (37%. When faced with diagnostic uncertainty, 84% of respondents would either follow-up and reassess the patient or discuss the case with a specialist, and 67% would contact a laboratory professional. The most useful test utilisation enablers were found to be: interpretive comments (78% of respondents, published guidelines (74%, and a dedicated laboratory phone line (72%. Conclusion: Primary care doctors acknowledge uncertainty with test result interpretation. Potential countermeasures include the addition of patient-specific interpretive comments, the availability of guidelines or algorithms, and a dedicated laboratory phone line. The benefit of enhanced test result interpretation would reduce diagnostic error rates.

  1. Results of Large-Scale Spacecraft Flammability Tests

    Science.gov (United States)

    Ferkul, Paul; Olson, Sandra; Urban, David L.; Ruff, Gary A.; Easton, John; T'ien, James S.; Liao, Ta-Ting T.; Fernandez-Pello, A. Carlos; Torero, Jose L.; Eigenbrand, Christian; hide

    2017-01-01

    For the first time, a large-scale fire was intentionally set inside a spacecraft while in orbit. Testing in low gravity aboard spacecraft had been limited to samples of modest size: for thin fuels the longest samples burned were around 15 cm in length and thick fuel samples have been even smaller. This is despite the fact that fire is a catastrophic hazard for spaceflight and the spread and growth of a fire, combined with its interactions with the vehicle cannot be expected to scale linearly. While every type of occupied structure on earth has been the subject of full scale fire testing, this had never been attempted in space owing to the complexity, cost, risk and absence of a safe location. Thus, there is a gap in knowledge of fire behavior in spacecraft. The recent utilization of large, unmanned, resupply craft has provided the needed capability: a habitable but unoccupied spacecraft in low earth orbit. One such vehicle was used to study the flame spread over a 94 x 40.6 cm thin charring solid (fiberglasscotton fabric). The sample was an order of magnitude larger than anything studied to date in microgravity and was of sufficient scale that it consumed 1.5 of the available oxygen. The experiment which is called Saffire consisted of two tests, forward or concurrent flame spread (with the direction of flow) and opposed flame spread (against the direction of flow). The average forced air speed was 20 cms. For the concurrent flame spread test, the flame size remained constrained after the ignition transient, which is not the case in 1-g. These results were qualitatively different from those on earth where an upward-spreading flame on a sample of this size accelerates and grows. In addition, a curious effect of the chamber size is noted. Compared to previous microgravity work in smaller tunnels, the flame in the larger tunnel spread more slowly, even for a wider sample. This is attributed to the effect of flow acceleration in the smaller tunnels as a result of hot

  2. Results of tests with open fuel in KNK II

    International Nuclear Information System (INIS)

    Schmitz, G.

    1987-03-01

    For the operation of Liquid Metal Cooled Fast Breeder Reactors with cladding failures the consequences of increased contamination by fission products and fuel and the possibility of failure propagation to adjacent fuel pins due to fuel swelling have to be envisaged. To clarify some of these problems a KNK II test program involving open fuel was defined with the first experiments of this program being performed between October 1981 and May 1984. After the description of the test equipment and of the test program, the results will be presented on delayed neutron measurements, fission gas measurements and post irradiation examinations. The report will conclude with a discussion of the results [de

  3. Thermal results of the Japanese LCT coil's domestic test

    International Nuclear Information System (INIS)

    Tada, Eisuke; Hiyama, Tadao; Kato, Takashi; Takahashi, Osamu; Shimamoto, Susumu

    1984-01-01

    This paper describes thermal results obtained in the domestic test of the Japanese LCT coil which was constructed at the Japan Atomic Energy Research Institute (JAERI) in order to develop large superconducting coils for fusion in international collaboration proposed by the IEA. The domestic test was carried out from May 13 to June 17 in 1982 by using the test facility named as SETF (Superconducting Engineering Test Facility) which was composed of a 350-l/h helium cryogenic system, a vacuum system, a 30 KA-DC power supply and protection system, and a PDP-11/70 computer system. The cool-down characteristics, heat load, fast discharge characteristics, stability, and warm-up characteristics of the LCT coil were successfully measured in the test. The details of thermal test results acquired in the cool-down, heat load measurement, fast discharge, and warm-up, and the comparison between measurements and calculations are described in this paper. (author)

  4. COMPARISON OF RESULTS OF THERMAL TESTS OF BALCONY DOORS

    Directory of Open Access Journals (Sweden)

    Golubev Stanislav Sergeevich

    2012-10-01

    Full Text Available Results of thermal tests of balcony doors are presented in the article. In the course of the research project, two types of doors were tested. The first type represents a PVC frame door (width 82 mm; it has a triple glazing (4K-16Ar-4-16Ar-K4; its blank part represents a polystyrene sandwich panel (width 40 mm. The second type represents a PVC frame door (width 82 mm, that has a triple glazing (4K-16Ar-4-16Ar-K4 and composite PVC panels. The testing procedure and processing results are described in the article. The test has demonstrated that the thermal resistance value of the balcony door of the first type exceeds the thermal resistance value of the balcony door of the second type.

  5. Challenges in interpretation of thyroid hormone test results

    Directory of Open Access Journals (Sweden)

    Lalić Tijana

    2016-01-01

    Full Text Available Introduction. In interpreting thyroid hormones results it is preferable to think of interference and changes in concentration of their carrier proteins. Outline of Cases. We present two patients with discrepancy between the results of thyroid function tests and clinical status. The first case presents a 62-year-old patient with a nodular goiter and Hashimoto thyroiditis. Thyroid function test showed low thyroid-stimulating hormone (TSH and normal to low fT4. By determining thyroid status (ТSH, T4, fT4, T3, fT3 in two laboratories, basal and after dilution, as well as thyroxine-binding globulin (TBG, it was concluded that the thyroid hormone levels were normal. The results were influenced by heterophile antibodies leading to a false lower TSH level and suspected secondary hypothyroidism. The second case, a 40-year-old patient, was examined and followed because of the variable size thyroid nodule and initially borderline elevated TSH, after which thyroid status showed low level of total thyroid hormones and normal TSH. Based on additional analysis it was concluded that low T4 and T3 were a result of low TBG. It is a hereditary genetic disorder with no clinical significance. Conclusion. Erroneous diagnosis of thyroid disorders and potentially harmful treatment could be avoided by proving the interference or TBG deficiency whenever there is a discrepancy between the thyroid function results and the clinical picture.

  6. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Tamura, M.; Endo, J.

    1982-02-01

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  7. Caltrans accelerated pavement testing (CAL/APT) program - test results: 1993-1996

    CSIR Research Space (South Africa)

    Nokes, WA

    1997-08-01

    Full Text Available By combining the results of both the HVS and laboratory tests, interpretations of pavement performance are described and recommendations for pavement design and construction have been made to Caltrans....

  8. Cement/bentonite interaction. Results from 16 month laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, O. [Clay Technology AB, Lund (Sweden)

    1997-12-01

    The work concerns possible bentonite clay mineral alteration in constructions with bentonite in close contact with cement, and the effect of such changes on bentonite buffer properties. The investigation comprises a 16 months laboratory test series with hydrothermal cell tests, percolation tests and diffusion tests. MX-80 Wyoming bentonite was used in all tests. Two types of artificial cement pore water solutions were used in the percolation and diffusion tests. The swelling pressure and the hydraulic conductivity were measured continuously in the percolation tests. After termination, the clay was analyzed with respect to changes in element distribution, mineralogy and shear strength. The water solutions were analyzed with respect to pH, cations and major anions. The results concerning chemical and mineralogical changes are in summary: Ion exchange in the montmorillonite until equilibrium with cement pore-water ions was reached; Increase in cation exchange capacity; Dissolution of original cristobalite; Increase in quartz content; Minor increase in illite content; Minor formation of chlorite; Formation of CSH(I); Wash away of CSH-gel into surrounding water. A large decrease in swelling pressure and a moderate increase in hydraulic conductivity were recorded in the samples percolated by SULFACEM pore-water solution. The mineralogical alterations only concerned a minor part of the total bentonite mass and the changes in physical properties were therefore most likely due to the replacement of the original charge balancing cation by cement pore-water cations. Comparisons between the current test result and results from 4 month tests indicate that the rates of illite and chlorite formation were reduced during the tests. The presence of zeolites in the clay could not be ensured. However, the discovery of CSH material is important since CSH is expected to precede the formation of zeolites 5 refs, 48 figs, 11 tabs

  9. Results from the 2013 drug and alcohol testing survey.

    Science.gov (United States)

    2015-12-01

    This report summarizes the results of the 2013 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) that test positive fo...

  10. Results from the 2008 Drug and Alcohol Testing Survey

    Science.gov (United States)

    2010-01-01

    This report summarizes the results of the 2008 Federal Motor Carrier Safety Administration Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses who test positive for controlled sub...

  11. EOL3 M0 X-ray Tomography Test Results

    CERN Document Server

    Avramidou, R; Bozhko, N; Borisov, A; Goriatchev, V; Goriatchev, S; Gushin, V; Fakhroutdinov, R; Kojine, A; Kononov, A; Larionov, A; Salomatin, Yu I; Schuh, S; Sedykh, Yu; Tchougouev, A

    2001-01-01

    Results of X-ray tomography test of EOL3 module 0 chamber is presented in the note. Peculiarities of the X-ray tomography of the chamber are discussed. Comparison of the tomography results with predictions of the production site measurements is made.

  12. Recent test results on the ATLAS SCT detector

    International Nuclear Information System (INIS)

    Pernegger, H.

    2003-01-01

    The ATLAS Semiconductor Tracker (SCT) will be a central part of the tracking system of the ATLAS experiment. The SCT, which is currently under construction, will consist of four concentric barrels of silicon detectors as well as two silicon endcap detectors formed by nine disks each. After an overview of the SCT and the detector module layout, the paper will summarize recent test results obtained from silicon detector modules, which have been extensively tested before starting their large series production. The tests presented here cover electrical performance of individual modules, their performance after irradiation, as well as system tests in a multi-module setup

  13. Improved PFB operations - 400-hour turbine test results

    Science.gov (United States)

    Rollbuhler, R. J.; Benford, S. M.; Zellars, G. R.

    1980-04-01

    The paper deals with a 400-hr small turbine test in the effluent of a pressurized fluidized bed (PFB) at an average temperature of 770 C, an average relative gas velocity of 300 m/sec, and average solid loadings of 200 ppm. Consideration is given to combustion parameters and operating procedure as well as to the turbine system and turbine test operating procedures. Emphasis is placed on erosion/corrosion results.

  14. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C. Edward; Klee, Paul M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted

  15. Results from the STAR TPC system test

    International Nuclear Information System (INIS)

    Betts, W.

    1996-01-01

    A system test of various components of the Solenoidal Tracker at RHIC (STAR) detector, operating in concern, has recently come on-line. Communication between a major sub-detector, a sector of the Time Projection Chamber (TPC), and the trigger, data acquisition and slow controls systems has been established, enabling data from cosmic ray muons to be collected. First results from an analysis of the TPC data are presented. These include measurements of system noise, electronic parameters such as amplifier gains and pedestal values, and tracking resolution for cosmic ray muons and laser induced ionization tracks. A discussion on the experience gained in integrating the different components for the system test is also given

  16. Results from tests of the Delphi TPC prototype

    International Nuclear Information System (INIS)

    Vilanova, D.

    1985-01-01

    Results from beam tests of a half-scale sector of the Delphi TPC are presented. The spatial resolution is slightly higher than predicted by Monte Carlo simulations, corresponding to an average value of about 300 μm. (orig.)

  17. Test-beam results of a SOI pixel detector prototype

    CERN Document Server

    Bugiel, Roma; Dannheim, Dominik; Fiergolski, Adrian; Hynds, Daniel; Idzik, Marek; Kapusta, P; Kucewicz, Wojciech; Munker, Ruth Magdalena; Nurnberg, Andreas Matthias

    2018-01-01

    This paper presents the test-beam results of a monolithic pixel-detector prototype fabricated in 200 nm Silicon-On-Insulator (SOI) CMOS technology. The SOI detector was tested at the CERN SPS H6 beam line. The detector is fabricated on a 500 μm thick high-resistivity float- zone n-type (FZ-n) wafer. The pixel size is 30 μm × 30 μm and its readout uses a source- follower configuration. The test-beam data are analysed in order to compute the spatial resolution and detector efficiency. The analysis chain includes pedestal and noise calculation, cluster reconstruction, as well as alignment and η-correction for non-linear charge sharing. The results show a spatial resolution of about 4.3 μm.

  18. Drug and alcohol testing results 2009 annual report

    Science.gov (United States)

    2013-11-01

    This is the 15th annual report of the results of the Federal Transit Administrations (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2009, the requirements of the overall drug and alcohol...

  19. Drug and alcohol testing results 2007 annual report

    Science.gov (United States)

    2009-05-01

    This is the 13th annual report of the results of the Federal Transit Administrations (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2007, the requirements of the overall drug and alcohol...

  20. Drug and Alcohol Testing Results 2008 Annual Report

    Science.gov (United States)

    2010-09-01

    This is the 14th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing : Program. This report summarizes the reporting requirements for calendar year 2008, the requirements of the overall : drug and alcoh...

  1. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Stallmann, F.W.; Guthrie, G.; McElroy, W.N.

    1985-01-01

    The ORR-PSF benchmark experiment was designed to simulate the surveillance capsule-pressure vessel configuration in power reactors and to test the validity of procedures which determine the radiation damage in the vessel from test results in the surveillance capsule. The PSF metallurgical blind test was initiated to give participants an opportunity to test their current embrittlement prediction methodologies. Experimental results were withheld from the participants except for the type of information which is normally contained in surveillance reports. Preliminary analysis of the PSF metallurgical blind test results shows that: (1) current prediction methodologies, as used by the PSF Blind Test participants, are adequate, falling within +- 20 0 C of the measured values for Δ NDT. None of the different methods is clearly superior; (2) the proposed revision of Reg. Guide 1.99 (Rev. 2) gives a better representation of the fluence and chemistry dependency of Δ NDT than the current version (Rev. 1); and (3) fluence rate effects can be seen but not quantified. Fluence spectral effects are too small to be detectable in this experiment. (orig.)

  2. Construction details and test results from RHIC sextupoles

    International Nuclear Information System (INIS)

    Lindner, M.; Anerella, M.; Ganetis, G.

    1993-01-01

    Four 8 cm aperture sextupoles have been built at BNL to verify the magnetic performance of this magnet in the RHIC installation. Two significantly different mechanical configurations have been designed, and two magnets of each design have been built, and successfully tested, and have exceeded the required minimum quench current by a substantial margin. This report describes the assembly details of the second configuration, which is the final production configuration. In addition the first industry built production sextupole has been delivered and tested. This report presents the results of quench tests on all 5 magnets and field measurements on the first production sextupole

  3. Long Term Corrosion/Degradation Test Six Year Results

    Energy Technology Data Exchange (ETDEWEB)

    M. K. Adler Flitton; C. W. Bishop; M. E. Delwiche; T. S. Yoder

    2004-09-01

    The Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) contains neutron-activated metals from non-fuel, nuclear reactor core components. The Long-Term Corrosion/Degradation (LTCD) Test is designed to obtain site-specific corrosion rates to support efforts to more accurately estimate the transfer of activated elements to the environment. The test is using two proven, industry-standard methods—direct corrosion testing using metal coupons, and monitored corrosion testing using electrical/resistance probes—to determine corrosion rates for various metal alloys generally representing the metals of interest buried at the SDA, including Type 304L stainless steel, Type 316L stainless steel, Inconel 718, Beryllium S200F, Aluminum 6061, Zircaloy-4, low-carbon steel, and Ferralium 255. In the direct testing, metal coupons are retrieved for corrosion evaluation after having been buried in SDA backfill soil and exposed to natural SDA environmental conditions for times ranging from one year to as many as 32 years, depending on research needs and funding availability. In the monitored testing, electrical/resistance probes buried in SDA backfill soil will provide corrosion data for the duration of the test or until the probes fail. This report provides an update describing the current status of the test and documents results to date. Data from the one-year and three-year results are also included, for comparison and evaluation of trends. In the six-year results, most metals being tested showed extremely low measurable rates of general corrosion. For Type 304L stainless steel, Type 316L stainless steel, Inconel 718, and Ferralium 255, corrosion rates fell in the range of “no reportable” to 0.0002 mils per year (MPY). Corrosion rates for Zircaloy-4 ranged from no measurable corrosion to 0.0001 MPY. These rates are two orders of magnitude lower than those specified in

  4. Drug and alcohol testing results 2006 annual report.

    Science.gov (United States)

    2008-08-01

    This is the 12th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2006, the requirements of the overall drug and alcohol t...

  5. Test beam results from the D0 end electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Roe, N.A.

    1991-11-01

    Test beam results are presented for the DO end electromagnetic calorimeter. Data were taken with electrons and pions ranging in energy from 5 GeV to 150 GeV. Results from the analysis of the test beam data are presented on energy resolution and linearity, stability and uniformity of response, position resolution and electron-pion separation

  6. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted. copyright 1997 American Institute of Physics

  7. Arc melter demonstration baseline test results

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O'Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process

  8. Oscillating-flow loss test results in rectangular heat exchanger passages

    Science.gov (United States)

    Wood, J. Gary

    1991-01-01

    Test results of oscillating flow losses in rectangular heat exchanger passages of various aspect ratios are given. This work was performed in support of the design of a free-piston Stirling engine (FPSE) for a dynamic space power conversion system. Oscillating flow loss testing was performed using an oscillating flow rig, which was based on a variable stroke and variable frequency linear drive motor. Tests were run over a range of oscillating flow parameters encompassing the flow regimes of the proposed engine design. Test results are presented in both tabular and graphical form and are compared against analytical predictions.

  9. Reproducibility problems of in-service ultrasonic testing results

    International Nuclear Information System (INIS)

    Honcu, E.

    1974-01-01

    The reproducibility of the results of ultrasonic testing is the basic precondition for its successful application in in-service inspection of changes in the quality of components of nuclear power installations. The results of periodic ultrasonic inspections are not satisfactory from the point of view of reproducibility. Regardless, the ultrasonic pulse-type method is suitable for evaluating the quality of most components of nuclear installations and often the sole method which may be recommended for inspection with regard to its technical and economic aspects. (J.B.)

  10. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  11. SIMS prototype System 3 test results: engineering analysis

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-01

    The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating are presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.

  12. SIMS prototype system 3 test results: Engineering analysis

    Science.gov (United States)

    1978-01-01

    The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating is presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.

  13. Space Launch System Base Heating Test: Experimental Operations & Results

    Science.gov (United States)

    Dufrene, Aaron; Mehta, Manish; MacLean, Matthew; Seaford, Mark; Holden, Michael

    2016-01-01

    NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Test methodology and conditions are presented, and base heating results from 76 runs are reported in non-dimensional form. Regions of high heating are identified and comparisons of various configuration and conditions are highlighted. Base pressure and radiometer results are also reported.

  14. Graphite electrode arc melter demonstration Phase 2 test results

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; O'Connor, W.K.; Oden, L.L.; Turner, P.C.

    1996-06-01

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau's Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of open-quotes as-receivedclose quotes heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process

  15. Spent fuel drying system test results (first dry-run)

    International Nuclear Information System (INIS)

    Klinger, G.S.; Oliver, B.M.; Abrefah, J.; Marschman, S.C.; MacFarlan, P.J.; Ritter, G.A.

    1998-07-01

    The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks in the basin have been detected and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site. Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL) on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of the first dry-run test, which was conducted without a fuel element. The empty test apparatus was subjected to a combination of low- and high-temperature vacuum drying treatments that were intended to mimic, wherever possible, the fuel treatment strategies of the IPS. The data from this dry-run test can serve as a baseline for the first two fuel element tests, 1990 (Run 1) and 3128W (Run 2). The purpose of this dry-run was to establish the background levels of hydrogen in the system, and the hydrogen generation and release characteristics attributable to the test system without a fuel element present. This test also serves to establish the background levels of water in the system and the water release characteristics. The system used for the drying test series was the Whole Element Furnace Testing System, described in Section 2.0, which is located in the Postirradiation Testing Laboratory (PTL, 327 Building). The test conditions and methodology are given in section 3.0, and the experimental

  16. Results and Analysis from Space Suit Joint Torque Testing

    Science.gov (United States)

    Matty, Jennifer

    2010-01-01

    This joint mobility KC lecture included information from two papers, "A Method for and Issues Associated with the Determination of Space Suit Joint Requirements" and "Results and Analysis from Space Suit Joint Torque Testing," as presented for the International Conference on Environmental Systems in 2009 and 2010, respectively. The first paper discusses historical joint torque testing methodologies and approaches that were tested in 2008 and 2009. The second paper discusses the testing that was completed in 2009 and 2010.

  17. Multi-bundle shashlik calorimeter prototypes beam-test results

    International Nuclear Information System (INIS)

    Badier, J.; Bloch, P.; Bityukov, S.; Bordalo, P.; Busson, P.; Charlot, C.; Dobrzynski, L.; Golutvin, I.; Guschin, E.; Issakov, V.; Ivanchenko, I.; Klimenko, V.; Marin, V.; Moissenz, P.; Obraztsov, V.; Ostankov, A.; Popov, V.; Puljak, I.; Ramos, S.; Seez, C.; Sergueev, S.; Soushkov, V.; Tanaka, R.; Varela, J.; Virdee, T.S.; Zaitchenko, A.; Zamiatin, N.

    1995-01-01

    The first beam-test results for two- and three-bundle shashlik tower prototypes are described. We found that the spatial resolution, the uniformity of energy response, the calorimeter reliability and hermeticity and also two showers separation are improved in multi-bundle design approach. ((orig.))

  18. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  19. New test methods for BIPV. Results from IP performance

    International Nuclear Information System (INIS)

    Jol, J.C.; Van Kampen, B.J.M.; De Boer, B.J.; Reil, F.; Geyer, D.

    2009-11-01

    Within the Performance project new test procedures for PV building products and the building performance as a whole when PV is applied in buildings have been drafted. It has resulted in a first draft of new test procedures for PV building products and proposals for tests for novel BIPV technology like thin film. The test proposed are a module breakage test for BIPV products, a fire safety test for BIPV products and a dynamic load test for BIPV products. Furthermore first proposals of how flexible PV modules could be tested in an appropriate way to ensure long time quality and safety of these new products are presented.

  20. Paternity tests in Mexico: Results obtained in 3005 cases.

    Science.gov (United States)

    García-Aceves, M E; Romero Rentería, O; Díaz-Navarro, X X; Rangel-Villalobos, H

    2018-04-01

    National and international reports regarding the paternity testing activity scarcely include information from Mexico and other Latin American countries. Therefore, we report different results from the analysis of 3005 paternity cases analyzed during a period of five years in a Mexican paternity testing laboratory. Motherless tests were the most frequent (77.27%), followed by trio cases (20.70%); the remaining 2.04% included different cases of kinship reconstruction. The paternity exclusion rate was 29.58%, higher but into the range reported by the American Association of Blood Banks (average 24.12%). We detected 65 mutations, most of them involving one-step (93.8% and the remaining were two-step mutations (6.2%) thus, we were able to estimate the paternal mutation rate for 17 different STR loci: 0.0018 (95% CI 0.0005-0.0047). Five triallelic patterns and 12 suspected null alleles were detected during this period; however, re-amplification of these samples with a different Human Identification (HID) kit confirmed the homozygous genotypes, which suggests that most of these exclusions actually are one-step mutations. HID kits with ≥20 STRs detected more exclusions, diminishing the rate of inconclusive results with isolated exclusions (Powerplex 21 kit (20 STRs) and Powerplex Fusion kit (22 STRs) offered similar PI (p = 0.379) and average number of exclusions (PE) (p = 0.339) when a daughter was involved in motherless tests. In brief, besides to report forensic parameters from paternity tests in Mexico, results describe improvements to solve motherless paternity tests using HID kits with ≥20 STRs instead of one including 15 STRs. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  1. Physical separations soil washing system cold test results

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.P.

    1993-07-28

    This test summary describes the objectives, methodology, and results of a physical separations soil-washing system setup and shakedown test using uncontaminated soil. The test is being conducted in preparation for a treatability test to be conducted in the North Pond of the 300-FF-1 Operable Unit. It will be used to assess the feasibility of using a physical separations process to reduce the volume of contaminated soils in the 300-FF-1 Operable Unit. The test is described in DOE-RL (1993). The setup test was conducted at an uncontrolled area located approximately 3.2 km northwest of the 300-FF-1 Operable Unit. The material processed was free of contamination. The physical separation equipment to be used in the test was transferred to the US Department of Energy (DOE) by the US Environmental Protection Agency (EPA) Risk Reduction Engineering Laboratory. On May 13, 1993, soil-washing equipment was moved to the cold test location. Design assistance and recommendation for operation was provided by the EPA.

  2. The TRANSRAPID propulsion system - development and test results

    Energy Technology Data Exchange (ETDEWEB)

    Henning, U [Siemens AG, Erlangen (Germany); Kamp, P G [Siemens AG, Erlangen (Germany); Hochleitner, J [Siemens AG, Erlangen (Germany)

    1996-12-31

    The structure of the propulsion system for the Transrapid comprises a number of components which are located along the guideway. These drive components are temporarily switched together to form the drive control zones necessary to permit maglev operation over the guideway. The paper describes the development of the stationary propulsion converter with GTO thyristors. The drive components are tested under realistic operating conditions. The test results confirm the performance capability as well as verify the suitability of the concept for use in revenue service. (HW)

  3. Results of Detailed Hydrologic Characterization Tests - Fiscal Year 2000

    International Nuclear Information System (INIS)

    Spane, Frank A; Thorne, Paul D; Newcomer, Darrell R

    2001-01-01

    This report provides the results of detailed hydrologic characterization tests conducted within eleven Hanford Site wells during fiscal year 2000. Detailed characterization tests performed included groundwater-flow characterization; barometric response evaluation; slug tests; single-well tracer tests; constant-rate pumping tests; and in-well, vertical flow tests. Hydraulic property estimates obtained from the detailed hydrologic tests include transmissivity; hydraulic conductivity; specific yield; effective porosity; in-well, lateral flow velocity; aquifer-flow velocity; vertical distribution of hydraulic conductivity (within the well-screen section); and in-well, vertical flow velocity. In addition, local groundwater-flow characteristics (i.e., hydraulic gradient and flow direction) were determined for four sites where detailed well testing was performed

  4. Results of HHF tests and metallographic investigation of beryllium HHF mockups

    International Nuclear Information System (INIS)

    Giniaytulin, R.; Komarov, V.; Mazul, I.; Yablokov, N.; Watson, R.; Cadden, C.; Yang, N.

    2000-01-01

    The reliability of the beryllium-armoured elements for any fusion facilities strongly depends from the armour tile geometry and determines by the armour thickness and how it is castellated in the planar dimensions. The mockup with the tile dimensions of 5 x 5 x 5 mm demonstrated best results during the HHF tests at EBTS facility (SNLA). Thermal response test demonstrated the ultimate heat flux level fo 16.6 MW/m 2 without failure of the joint, melting of the beryllium surface limited the level of the heat flux. During thousand cycles by heat flux density of 13.5 MW/m 2 no damages in the Be/CuCrZr joint occurred that was approved by metallographic investigation of the tested and non-tested cross-sections. This paper presents the results of HHF testing with Be-armoured mockup that has optimized armour geometry, 2-D temperature analysis for testing conditions and the results of metallographic analysis. The results are discussed and the recommendations for armour dimensions are also made. (orig.)

  5. Graphite electrode arc melter demonstration Phase 2 test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; O`Connor, W.K.; Oden, L.L.; Turner, P.C.

    1996-06-01

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau`s Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of {open_quotes}as-received{close_quotes} heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process.

  6. Tensile and fracture toughness test results of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Chaouadi, R.; Moons, F.; Puzzolante, J.L. [Centre d`Etude de l`Energie Nucleaire, Mol (Belgium)

    1998-01-01

    Tensile and fracture toughness test results of four Beryllium grades are reported here. The flow and fracture properties are investigated by using small size tensile and round compact tension specimens. Irradiation was performed at the BR2 material testing reactor which allows various temperature and irradiation conditions. The fast neutron fluence (>1 MeV) ranges between 0.65 and 2.45 10{sup 21} n/cm{sup 2}. In the meantime, un-irradiated specimens were aged at the irradiation temperatures to separate if any the effect of temperature from irradiation damage. Test results are analyzed and discussed, in particular in terms of the effects of material grade, test temperature, thermal ageing and neutron irradiation. (author)

  7. Laboratory results of the AOF system testing

    Science.gov (United States)

    Kolb, Johann; Madec, Pierre-Yves; Arsenault, Robin; Oberti, Sylvain; Paufique, Jérôme; La Penna, Paolo; Ströbele, Stefan; Donaldson, Robert; Soenke, Christian; Suárez Valles, Marcos; Kiekebusch, Mario; Argomedo, Javier; Le Louarn, Miska; Vernet, Elise; Haguenauer, Pierre; Duhoux, Philippe; Aller-Carpentier, Emmanuel; Valenzuela, Jose Javier; Guerra, Juan Carlos

    2016-07-01

    For two years starting in February 2014, the AO modules GRAAL for HAWK-I and GALACSI for MUSE of the Adaptive Optics Facility project have undergone System Testing at ESO's Headquarters. They offer four different modes: NGS SCAO, LGS GLAO in the IR, LGS GLAO and LTAO in the visible. A detailed characterization of those modes was made possible by the existence of ASSIST, a test bench emulating an adaptive VLT including the Deformable Secondary Mirror, a star simulator and turbulence generator and a VLT focal plane re-imager. This phase aimed at validating all the possible components and loops of the AO modules before installation at the actual VLT that comprises the added complexity of real LGSs, a harsher non-reproducible environment and the adaptive telescope control. In this paper we present some of the major results obtained and challenges encountered during the phase of System Tests, like the preparation of the Acquisition sequence, the testing of the Jitter loop, the performance optimization in GLAO and the offload of low-order modes from the DSM to the telescope (restricted to the M2 hexapod). The System Tests concluded with the successful acceptance, shipping, installation and first commissioning of GRAAL in 2015 as well as the acceptance and shipping of GALACSI, ready for installation and commissioning early 2017.

  8. PISA TESTS IN LATIN AMERICA: RESULTS IN CONTEXT

    Directory of Open Access Journals (Sweden)

    Guillermina Tiramonti

    2014-05-01

    Full Text Available The educational reforms implemented in Latin America in the ‘90s introduced changes in the modes of regulation of educational systems based on the adoption of mechanisms for assessing student achievement. Since 2000, eight Latin-American countries (Argentina, Chile, Uruguay, Colombia, Brazil, Costa Rica, Mexico and Peru are involved in the PISA tests. The article presents a brief review of the social and educational situation of the Region, relevant for the interpretation and comparative analysis of the results of these tests that is presented below.

  9. Interpretation of Chemical Pathology Test Results in Paediatrics ...

    African Journals Online (AJOL)

    At any time we interprete paediatric chemical pathology test results we must take into consideration a number of factors, which are related with and restricted to paediatric patients. Such factors include the paediatric patient's age that may change from prematurity to above 18 years, and the paediatric patient's body weight ...

  10. ExEP yield modeling tool and validation test results

    Science.gov (United States)

    Morgan, Rhonda; Turmon, Michael; Delacroix, Christian; Savransky, Dmitry; Garrett, Daniel; Lowrance, Patrick; Liu, Xiang Cate; Nunez, Paul

    2017-09-01

    EXOSIMS is an open-source simulation tool for parametric modeling of the detection yield and characterization of exoplanets. EXOSIMS has been adopted by the Exoplanet Exploration Programs Standards Definition and Evaluation Team (ExSDET) as a common mechanism for comparison of exoplanet mission concept studies. To ensure trustworthiness of the tool, we developed a validation test plan that leverages the Python-language unit-test framework, utilizes integration tests for selected module interactions, and performs end-to-end crossvalidation with other yield tools. This paper presents the test methods and results, with the physics-based tests such as photometry and integration time calculation treated in detail and the functional tests treated summarily. The test case utilized a 4m unobscured telescope with an idealized coronagraph and an exoplanet population from the IPAC radial velocity (RV) exoplanet catalog. The known RV planets were set at quadrature to allow deterministic validation of the calculation of physical parameters, such as working angle, photon counts and integration time. The observing keepout region was tested by generating plots and movies of the targets and the keepout zone over a year. Although the keepout integration test required the interpretation of a user, the test revealed problems in the L2 halo orbit and the parameterization of keepout applied to some solar system bodies, which the development team was able to address. The validation testing of EXOSIMS was performed iteratively with the developers of EXOSIMS and resulted in a more robust, stable, and trustworthy tool that the exoplanet community can use to simulate exoplanet direct-detection missions from probe class, to WFIRST, up to large mission concepts such as HabEx and LUVOIR.

  11. Test result communication in primary care: a survey of current practice.

    Science.gov (United States)

    Litchfield, Ian; Bentham, Louise; Lilford, Richard; McManus, Richard J; Hill, Ann; Greenfield, Sheila

    2015-11-01

    The number of blood tests ordered in primary care continues to increase and the timely and appropriate communication of results remains essential. However, the testing and result communication process includes a number of participants in a variety of settings and is both complicated to manage and vulnerable to human error. In the UK, guidelines for the process are absent and research in this area is surprisingly scarce; so before we can begin to address potential areas of weakness there is a need to more precisely understand the strengths and weaknesses of current systems used by general practices and testing facilities. We conducted a telephone survey of practices across England to determine the methods of managing the testing and result communication process. In order to gain insight into the perspectives from staff at a large hospital laboratory we conducted paired interviews with senior managers, which we used to inform a service blueprint demonstrating the interaction between practices and laboratories and identifying potential sources of delay and failure. Staff at 80% of practices reported that the default method for communicating normal results required patients to telephone the practice and 40% of practices required that patients also call for abnormal results. Over 80% had no fail-safe system for ensuring that results had been returned to the practice from laboratories; practices would otherwise only be aware that results were missing or delayed when patients requested results. Persistent sources of missing results were identified by laboratory staff and included sample handling, misidentification of samples and the inefficient system for collating and resending misdirected results. The success of the current system relies on patients both to retrieve results and in so doing alert staff to missing and delayed results. Practices appear slow to adopt available technological solutions despite their potential for reducing the impact of recurring errors in the

  12. Preliminary Results of Breakwater Round-Head Tests

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    1995-01-01

    The rational design diagram for Dolos armour should incorporate both the hydraulic stability and the structural integrity. The previous tests performed by Aalborg University (AU) made available such design diagram for the trunk of Dolos breakwater without superstructures (Burcharth et al. 1992). ...... layer will be generated. Furthermore, Task IA will give the design diagram for the trunk of Tetrapod breakwaters. The more complete research results on Dolosse can certainly give some insight into the behaviour of Tetrapods armour layer of the breakwaters with superstructure....

  13. The Benchmark Test Results of QNX RTOS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Yeol; Lee, Young Jun; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

  14. The Benchmark Test Results of QNX RTOS

    International Nuclear Information System (INIS)

    Kim, Jang Yeol; Lee, Young Jun; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon

    2010-01-01

    A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

  15. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  16. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  17. Honeywell Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  18. Full length prototype SSC dipole test results

    International Nuclear Information System (INIS)

    Strait, J.; Brown, B.C.; Carson, J.

    1987-01-01

    Results are presented from tests of the first full length prototype SSC dipole magnet. The cryogenic behavior of the magnet during a slow cooldown to 4.5K and a slow warmup to room temperature has been measured. Magnetic field quality was measured at currents up to 2000 A. Averaged over the body field all harmonics with the exception of b 2 and b 8 are at or within the tolerances specified by the SSC Central Design Group. (The values of b 2 and b 8 result from known design and construction defects which will be be corrected in later magnets.) Using an NMR probe the average body field strength is measured to be 10.283 G/A with point to point variations on the order of one part in 1000. Data are presented on quench behavior of the magnet up to 3500 A (approximately 55% of full field) including longitudinal and transverse velocities for the first 250 msec of the quench

  19. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  20. DEWATERING TREATMENT SCALE-UP TESTING RESULTS OF HANFORD TANK WASTES

    International Nuclear Information System (INIS)

    TEDESCHI AR

    2008-01-01

    This report documents CH2M HILL Hanford Group Inc. (CH2M HILL) 2007 dryer testing results in Richland, WA at the AMEC Nuclear Ltd., GeoMelt Division (AMEC) Horn Rapids Test Site. It provides a discussion of scope and results to qualify the dryer system as a viable unit-operation in the continuing evaluation of the bulk vitrification process. A 10,000 liter (L) dryer/mixer was tested for supplemental treatment of Hanford tank low-activity wastes, drying and mixing a simulated non-radioactive salt solution with glass forming minerals. Testing validated the full scale equipment for producing dried product similar to smaller scale tests, and qualified the dryer system for a subsequent integrated dryer/vitrification test using the same simulant and glass formers. The dryer system is planned for installation at the Hanford tank farms to dry/mix radioactive waste for final treatment evaluation of the supplemental bulk vitrification process

  1. Dual color radiometer imagery and test results

    International Nuclear Information System (INIS)

    Silver, A.; Carlen, F.; Link, D.; Zegel, F.

    1989-01-01

    This paper presents a review of the technical characteristics of the Dual Color Radiometer and recent data and test results. The Dual Color Radiometer is a state-of-the-art device that provides simultaneous pixel to pixel registered thermal imagery in both the 3 to 5 and 8 to 12 micron regions. The device is unique in terms of its spatial and temperature resolution of less than 0.10 degrees C temperature and 0.10 milliradian spatial resolution. In addition, the device is tailored for use by the Automatic Target Recognizer (ATR) community

  2. Thermosyphon Flooding in Reduced Gravity Environments Test Results

    Science.gov (United States)

    Gibson, Marc A.; Jaworske, Donald A.; Sanzi, Jim; Ljubanovic, Damir

    2013-01-01

    The condenser flooding phenomenon associated with gravity aided two-phase thermosyphons was studied using parabolic flights to obtain the desired reduced gravity environment (RGE). The experiment was designed and built to test a total of twelve titanium water thermosyphons in multiple gravity environments with the goal of developing a model that would accurately explain the correlation between gravitational forces and the maximum axial heat transfer limit associated with condenser flooding. Results from laboratory testing and parabolic flights are included in this report as part I of a two part series. The data analysis and correlations are included in a follow on paper.

  3. SMS messages increase adherence to rapid diagnostic test results among malaria patients: results from a pilot study in Nigeria.

    Science.gov (United States)

    Modrek, Sepideh; Schatzkin, Eric; De La Cruz, Anna; Isiguzo, Chinwoke; Nwokolo, Ernest; Anyanti, Jennifer; Ujuju, Chinazo; Montagu, Dominic; Liu, Jenny

    2014-02-25

    The World Health Organization now recommends parasitological confirmation for malaria case management. Rapid diagnostic tests (RDTs) for malaria are an accurate and simple diagnostic to confirm parasite presence in blood. However, where they have been deployed, adherence to RDT results has been poor, especially when the test result is negative. Few studies have examined adherence to RDTs distributed or purchased through the private sector. The Rapid Examination of Malaria and Evaluation of Diagnostic Information (REMEDI) study assessed the acceptability of and adherence to RDT results for patients seeking care from private sector drug retailers in two cities in Oyo State in south-west Nigeria. In total, 465 adult participants were enrolled upon exit from a participating drug shop having purchased anti-malaria drugs for themselves. Participants were given a free RDT and the appropriate treatment advice based on their RDT result. Short Message Service (SMS) text messages reiterating the treatment advice were sent to a randomly selected half of the participants one day after being tested. Participants were contacted via phone four days after the RDT was conducted to assess adherence to the RDT information and treatment advice. Adherence to RDT results was 14.3 percentage points (P-val <0.001) higher in the treatment group who were sent the SMS. The higher adherence in the treatment group was robust to several specification tests and the estimated difference in adherence ranged from 9.7 to 16.1 percentage points. Further, the higher adherence to the treatment advice was specific to the treatment advice for anti-malarial drugs and not other drugs purchased to treat malaria symptoms in the RDT-negative participants who bought both anti-malarial and symptom drugs. There was no difference in adherence for the RDT-positive participants who were sent the SMS. SMS text messages substantially increased adherence to RDT results for patients seeking care for malaria from

  4. 7 CFR 29.431 - Handling of imported tobacco pending test results.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Handling of imported tobacco pending test results. 29.431 Section 29.431 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING... tobacco pending test results. After an individual shipment of imported flue-cured or burley tobacco has...

  5. Wind tunnel test IA300 analysis and results, volume 1

    Science.gov (United States)

    Kelley, P. B.; Beaufait, W. B.; Kitchens, L. L.; Pace, J. P.

    1987-01-01

    The analysis and interpretation of wind tunnel pressure data from the Space Shuttle wind tunnel test IA300 are presented. The primary objective of the test was to determine the effects of the Space Shuttle Main Engine (SSME) and the Solid Rocket Booster (SRB) plumes on the integrated vehicle forebody pressure distributions, the elevon hinge moments, and wing loads. The results of this test will be combined with flight test results to form a new data base to be employed in the IVBC-3 airloads analysis. A secondary objective was to obtain solid plume data for correlation with the results of gaseous plume tests. Data from the power level portion was used in conjunction with flight base pressures to evaluate nominal power levels to be used during the investigation of changes in model attitude, eleveon deflection, and nozzle gimbal angle. The plume induced aerodynamic loads were developed for the Space Shuttle bases and forebody areas. A computer code was developed to integrate the pressure data. Using simplified geometrical models of the Space Shuttle elements and components, the pressure data were integrated to develop plume induced force and moments coefficients that can be combined with a power-off data base to develop a power-on data base.

  6. Patch Test Results of 775 Patients with Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Simin Ada

    2010-12-01

    Full Text Available Background and Design: The allergens responsible for allergic contact dermatitis vary among countries and even between different geographical regions within the same country over time. It is of great importance to perform the patch test at certain intervals, to evaluate the results in different centers and to compare them afterwards. Our aim was to evaluate the patch test results in our patients with allergic contact dermatitis.Material and Method: The records of the patients with allergic contact dermatitis, who had been patch tested between May 1997 and March 2009, were analyzed retrospectively. The demographic features such as age and sex, localization of the contact dermatitis, and the patch test results were recorded. Results: Of the 775 patients, 581 (75.2% were females and 194 (25% males. Of all patients, 735 were patch tested with the European Standard Series, 318 - with both the European Standard Series and cosmetic series, and 40-with cosmetic series alone. Of the patients tested with the European Standard Series, 255 (34.7% had at least one positive reaction. The most frequent allergen in the European Standard Series was nickel sulfate (17.3%, followed by cobalt chloride (7.2%, potassium dichromate (3%, fragrance mix (2.9%, and p-phenylenediamine base (2.6%. Of the 358 patients tested with cosmetic series, 82 (22.9% had at least one positive reaction. The 5 most frequently observed cosmetic series allergens were octyl gallate (3.9%, thimerosal (2.2%, sorbitan sesquioleate (2%, Euxyl K 400 (2% and methyldibromo glutaronitrile (1.4%. Conclusion: Our study shows the contact allergen profile of our center over 12 years. The most common allergens and their frequency differ between centers in various cities in Turkey. Those geographical differences should be re-evaluated by further studies performed in the certain time period. The high frequency of reactions to octyl gallate is an important finding in patients suspected of cosmetic allergy

  7. Structural fatigue test results for large wind turbine blade sections

    Science.gov (United States)

    Faddoul, J. R.; Sullivan, T. L.

    1982-01-01

    In order to provide quantitative information on the operating life capabilities of wind turbine rotor blade concepts for root-end load transfer, a series of cantilever beam fatigue tests was conducted. Fatigue tests were conducted on a laminated wood blade with bonded steel studs, a low cost steel spar (utility pole) with a welded flange, a utility pole with additional root-end thickness provided by a swaged collar, fiberglass spars with both bonded and nonbonded fittings, and, finally, an aluminum blade with a bolted steel fitting (Lockheed Mod-0 blade). Photographs, data, and conclusions for each of these tests are presented. In addition, the aluminum blade test results are compared to field failure information; these results provide evidence that the cantilever beam type of fatigue test is a satisfactory method for obtaining qualitative data on blade life expectancy and for identifying structurally underdesigned areas (hot spots).

  8. Automotive RF immunity test set-up analysis : why test results can't compare

    NARCIS (Netherlands)

    Coenen, Mart; Pues, H.; Bousquet, T.

    2011-01-01

    Though the automotive RF emission and RF immunity requirements are highly justifiable, the application of those requirements in an non-intended manner leads to false conclusions and unnecessary redesigns for the electronics involved. When the test results become too dependent upon the test set-up

  9. Use of laboratory test results in patient management by clinicians in Malawi.

    Science.gov (United States)

    Moyo, Kundai; Porter, Carol; Chilima, Ben; Mwenda, Reuben; Kabue, Mark; Zungu, Lutho; Sarr, Abdoulaye

    2015-11-18

    Malawi has a high burden of infectious disease. The expansion of programmes targeting these diseases requires a strong laboratory infrastructure to support both diagnosis and treatment. To assess the use of laboratory test results in patient management and to determine the requirements for improving laboratory services. A cross-sectional study was conducted in 2012 to survey practising clinicians. Two hospitals were purposively selected for observations of clinicians ordering laboratory tests. Twelve management-level key informants were interviewed. Descriptive statistics were conducted. A total of 242 clinicians were identified and 216 (89%) were interviewed. Of these, 189 (87%) reported doubting laboratory test results at some point. Clinicians most often doubted the quality of haematology (67%), followed by malaria (53%) and CD4 (22%) test results. A total of 151 (70%) clinicians reported using laboratory tests results in patient management. Use of laboratory test results at all times in patient management varied by the type of health facility ( P management. Key informants reported that the quality of laboratory services was good and useful, but that services were often unavailable. Gaps in the public laboratory system were evident. Key recommendations to enhance the use of laboratory test results in patient management were to strengthen the supply chain, reduce turn-around times, improve the test menu and improve the laboratory infrastructure.

  10. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  11. Almagate interference in breath test results for the diagnosis of Helicobacter pylori infection

    Directory of Open Access Journals (Sweden)

    Carles Pons

    2014-08-01

    Full Text Available Background: Infection by Helicobacter pylori is common and affects both genders at any age. The 13C-urea breath test is a widely used test for the diagnosis of this infection. However, multiple drugs used for the treatment of Helicobacter pylori infection symptoms have interactions with this breath test that generate false negative results. This observational study was to assess the potential interaction between almagate and the breath test. Methods: Thirty subjects on almagate therapy who underwent a breath test were included. If the result was negative, almagate was withdrawn for a month and the breath test was then repeated. Results: In general, 51.9 % of assessed subjects had a negative result after the first test, and 100 % of these also had a negative result after the second test. Conclusions: It was concluded that the use of almagate does not interfere in breath test results. These results provide a drug therapy option for the treatment of symptoms associated with Helicobacter pylori infection during the diagnostic process.

  12. Results of MACE tests M0 and M1

    International Nuclear Information System (INIS)

    Spencer, B.W.; Farmer, M.T.; Armstrong, D.R.; Kilsdonk, D.J.; Aeschlimann, R.W.; Fischer, M.

    1992-01-01

    This document discusses the Melt Attack and Coolability Experiment (MACE) Program underway at Argonne National Laboratory under ACE/EPRI sponsorship. The program addresses the efficacy of water to terminate an accident situation if melt progression were to result in a molten core/concrete interaction (MCCI) in the reactor containment. Large-scale experiments are being conducted in parallel with related modeling efforts, involving the addition of water to an MCI already underway. The experiments utilize UO 2 /ZrO 2 /Zr corium mixtures, direct electrical heating for simulation of decay heating, and various types of concrete basemats. Currently the tests involve 430 kg corium mass, 25 cm depth, in a 50 cm square test section. Test MO was a successful scoping test, but the first full size test, Ml, failed to achieve melt-water contact owing to existence of a preexisting bridge crust of corium charge. A heat flux of 3.5 MW/m 2 was measured in MO which removed energy from the corium pool equivalent to its entire heat of solidification prior to abatement by formation of an interfacial crust. The crust subsequently limited heat extraction to 600 kW/m 2 and less. Both tests MO and Ml revealed physical evidence of large pool swelling events which resulted in extrusion (and ejection) of melt into water above the crust, significantly increasing the overall quench and reducing the remaining melt in contact with the concrete. Furthermore, test Ml provided evidence of occasional ''burst mode'' ablation events and one additional important benefit of overlying water -- aerosol capture

  13. Results of assembly test of HTTR reactor internals

    International Nuclear Information System (INIS)

    Maruyama, S.; Saikusa, A.; Shiozawa, S.; Tsuji, N.; Miki, T.

    1996-01-01

    The assembly test of the HTTR actual reactor internals had been carried out at the works, prior to their installation in the actual reactor pressure vessel(RPV) at the construction site. The assembly test consists of several items such as examining fabricating precision of each component and alignment of piled-up structures, measuring circumferential coolant velocity profile in the passage between the simulated RPV and the reactor internals as well as under the support plates, measuring by-pass flow rate through gaps between the reactor internals, and measuring the binding force of the core restraint mechanism. Results of the test showed good performance of the HTTR reactor internals. Installation of the reactor internals in the actual RPV was started at the construction site of HTTR in April, 1995. In the installation process, main items of the assembly test at the works were repeated to investigate the reproducibility of installation. (author). 5 refs, 11 figs

  14. Results from Second Round of Remediated Nitrate Salt Surrogate Formulation and Testing

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Geoffrey Wayne [Los Alamos National Laboratory; Leonard, Philip [Los Alamos National Laboratory; Hartline, Ernest Leon [Los Alamos National Laboratory; Tian, Hongzhao [Los Alamos National Laboratory

    2016-04-04

    High Explosives and Technology (M-7) completed the second round of formulation and testing of Remediated Nitrate Salt (RNS) surrogates on March 17, 2016. This report summarizes the results of the work and also includes additional documentation required under test plan PLAN-TA9-2443 Rev B, "Remediated Nitrate Salt (RNS) Surrogate Formulation and Testing Standard Procedure", released February 16, 2016. All formulation and testing was carried out according to PLAN-TA9-2443 Rev B. Results from the first round of formulation and testing were documented in memorandum M7-16-6042, "Results from First Round of Remediated Nitrate Salt Surrogate Formulation and Testing."

  15. Thermal Analysis of Low Layer Density Multilayer Insulation Test Results

    Science.gov (United States)

    Johnson, Wesley L.

    2011-01-01

    Investigation of the thermal performance of low layer density multilayer insulations is important for designing long-duration space exploration missions involving the storage of cryogenic propellants. Theoretical calculations show an analytical optimal layer density, as widely reported in the literature. However, the appropriate test data by which to evaluate these calculations have been only recently obtained. As part of a recent research project, NASA procured several multilayer insulation test coupons for calorimeter testing. These coupons were configured to allow for the layer density to be varied from 0.5 to 2.6 layer/mm. The coupon testing was completed using the cylindrical Cryostat-l00 apparatus by the Cryogenics Test Laboratory at Kennedy Space Center. The results show the properties of the insulation as a function of layer density for multiple points. Overlaying these new results with data from the literature reveals a minimum layer density; however, the value is higher than predicted. Additionally, the data show that the transition region between high vacuum and no vacuum is dependent on the spacing of the reflective layers. Historically this spacing has not been taken into account as thermal performance was calculated as a function of pressure and temperature only; however the recent testing shows that the data is dependent on the Knudsen number which takes into account pressure, temperature, and layer spacing. These results aid in the understanding of the performance parameters of MLI and help to complete the body of literature on the topic.

  16. Clinical Trial Results Summary for Laypersons: A User Testing Study.

    Science.gov (United States)

    Raynor, D K; Myers, L; Blackwell, K; Kress, B; Dubost, A; Joos, A

    2018-01-01

    To apply "user testing" to maximize readability and acceptability of a Clinical Trial Results Laypersons Summary-a new European requirement. "User testing" (using questionnaire and semistructured interview) assessed whether people could find and understand key points. Findings were used to improve content and design, prior to retesting. Participants had a range of levels of health literacy and there was a higher education group. Participants accessed the summary on screen. In round 1 we tested 12 points of information. In round 2 a revised summary addressing round 1 findings was tested, leading to a third final version. In round 1, 2 of 12 points of information did not reach the target and interviews raised further format and content issues (some distracting technical explanations and inability to find or understand the 2 main study purposes). These findings informed revisions for the version tested in round 2, with 2 different points not reaching the target (inclusion criteria relating to duration of seasonal allergies and how researchers found out about participants' symptoms). Identified problems in both rounds were addressed and reflected in the final version. Despite improvements, participants did not consistently understand that summaries were intended for the public, or to only interpret results of single trials in the context of additional trials. All readers, including those with higher education, found the clear and straightforward language acceptable. Applying "user testing" resulted in a largely health-literate summary suitable for people across a range of backgrounds.

  17. Test Results of the ALICE-HMPID Detector Commissioning

    CERN Document Server

    Volpe, G

    2008-01-01

    The ALICE High Momentum Particle Identification Detector (HMPID) consists of seven identical proximity focusing RICH counters. It covers in total 11 m2, exploiting large area CsI photocathodes for Cherenkov light imaging. The detector is installed in the ALICE solenoid, ready for the data acquisition. By means of the Detector Control System, the Front-end (FEE) and the Readout (R/O) electronics, the MWPC high voltages, the cooling and the gas system have been tested. The HMPID module gas pressure, temperature, current and voltage trends have been monitored and archived in the ORACLE database. In this paper a comprehensive review on the test results is presented.

  18. Synthesis of low cycle fatigue test results

    International Nuclear Information System (INIS)

    Andrews, R.M.

    1990-01-01

    Axial strain controlled cycle fatigue tests were carried out on type 316 stainless steel parent metal, vacuum and non-vacuum electron beams welds, submerged arc welds and gas shielded metal arc welds. Testing covered total strains in the range 0.6% to 2%, and was at room temperature and 550 0 C. Parent metal and the electron beam welds showed rapid cyclic hardening, while arc welds showed little hardening. The weld metal cyclic stress-strain response was above that obtained for the parent metal, although below data obtained by other workers for similar parent materials. Weld metal endurances were above the ASME N47 continuous cycling design line at both temperatures, and comparable with parent metal data. However, the weld metal data approached the design line at low strain ranges (around 0.5%). Endurances were predicted from crack growth rates estimated from striation spacings, giving acceptable results except for the gas shielded metal arc weldments. (author)

  19. Do negative screening test results cause false reassurance? A systematic review.

    Science.gov (United States)

    Cooper, Grace C; Harvie, Michelle N; French, David P

    2017-11-01

    It has been suggested that receiving a negative screening test result may cause false reassurance or have a 'certificate of health effect'. False reassurance in those receiving a negative screening test result may result in them wrongly believing themselves to be at lower risk of the disease, and consequently less likely to engage in health-related behaviours that would lower their risk. The present systematic review aimed to identify the evidence regarding false reassurance effects due to negative screening test results in adults (over 18 years) screened for the presence of a disease or its precursors, where disease or precursors are linked to lifestyle behaviours. MEDLINE and PsycINFO were searched for trials that compared a group who had received negative screening results to an unscreened control group. The following outcomes were considered as markers of false reassurance: perceived risk of disease; anxiety and worry about disease; health-related behaviours or intention to change health-related behaviours (i.e., smoking, diet, physical activity, and alcohol consumption); self-rated health status. Nine unique studies were identified, reporting 55 measures in relation to the outcomes considered. Outcomes were measured at various time points from immediately following screening to up to 11 years after screening. Despite considerable variation in outcome measures used and timing of measurements, effect sizes for comparisons between participants who received negative screening test results and control participants were typically small with few statistically significant differences. There was evidence of high risk of bias, and measures of behaviours employed were often not valid. The limited evidence base provided little evidence of false reassurance following a negative screening test results on any of four outcomes examined. False reassurance should not be considered a significant harm of screening, but further research is warranted. Statement of contribution

  20. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  1. Pressure locking test results

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, open-quotes Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.close quotes Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; we will publish the results of our thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions

  2. Field test of a leak detection system: planning, execution and results

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio da Silva; Daniel; Melo Filho, Silvio A.; Niehues de Farias, Mauro; Pacheco, Anderson [Petrobas Transporte SA - TRANSPETRO, (Brazil)

    2010-07-01

    The OLAPA pipeline (Brazil) with its 97.6 km in length crosses difficult environment with a combination of mountain and dense forest. The non-detection of leaks in this kind of pipeline would have serious consequences. This pipeline was chosen for testing the performance of a new TRANSPETRO leak detection system. This paper reports the testing process of the new leakage detection method carried out on the OLAPA pipeline. TRANSPETRO decided to test the leakwarn system which is a computational pipeline monitoring (CPM) method which and can be integrated into their SCADA system. The CPM uses the mass balance principle with line pack change to analyze the pipeline operational parameters. The tests consisted of comparing the theoretical results with in-field results of alarm times obtained from controlled removal of product, simulating a real leak. Three leaks were tested in different states of operation and size of leak. It was found that the results were compatible with the expected alarm time.

  3. Influence of diet on the results of laboratory tests

    Directory of Open Access Journals (Sweden)

    Kinga Lis

    2013-12-01

    Full Text Available Blood and urine laboratory tests are necessary to diagnose the state of the patient. These tests are also helpful in the assessment of diet and nutritional status of the organism. It is recommended that both blood and urine for laboratory tests be collected in the morning, from fasting patients after an overnight rest. These conditions are defined as the standard conditions for collection of material for laboratory testing. Before testing, patients should follow their natural diet and avoid physical exertion, night work, long-distance travel, as well as consumption of alcohol and drugs. They should also reduce the consumption of synthetic vitamins and herbal remedies and other dietary supplements. Medications should be limited to those that are absolutely necessary. All of these factors can affect the results of laboratory tests.

  4. Proposed Interventions to Decrease the Frequency of Missed Test Results

    Science.gov (United States)

    Wahls, Terry L.; Cram, Peter

    2009-01-01

    Numerous studies have identified that delays in diagnosis related to the mishandling of abnormal test results are an import contributor to diagnostic errors. Factors contributing to missed results included organizational factors, provider factors and patient-related factors. At the diagnosis error conference continuing medical education conference…

  5. Melter operation results in chemical test at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Kanehira, Norio; Yoshioka, Masahiro; Muramoto, Hitoshi; Oba, Takaaki; Takahashi, Yuji

    2005-01-01

    Chemical Test of the glass melter system of the Vitrification Facility at Rokkasho Reprocessing Plant (RRP) was performed. In this test, basic performance of heating-up of the melter, melting glass, pouring glass was confirmed using simulated materials. Through these tests and operation of all modes, good results were gained, and training of operators was completed. (author)

  6. Test Results for the Automated Rendezvous and Capture System

    Science.gov (United States)

    Cruzen, Craig; Dabney, Richard; Lomas, James

    1999-01-01

    The Automated Rendezvous and Capture (AR&C) system was designed and tested at NASA's Marshall Space Flight Center (MSFC) to demonstrate technologies and mission strategies for automated rendezvous and docking of spacecraft in Earth orbit, The system incorporates some of the latest innovations in Global Positioning, System space navigation, laser sensor technologies and automated mission sequencing algorithms. The system's initial design and integration was completed in 1998 and has undergone testing at MSFC. This paper describes the major components of the AR&C system and presents results from the official system tests performed in MSFC's Flight Robotics Laboratory with digital simulations and hardware in the loop tests. The results show that the AR&C system can safely and reliably perform automated rendezvous and docking missions in the absence of system failures with 100 percent success. When system failures are included, the system uses its automated collision avoidance maneuver logic to recover in a safe manner. The primary objective of the AR&C project is to prove that by designing a safe and robust automated system, mission operations cost can be reduced by decreasing the personnel required for mission design, preflight planning and training required for crewed rendezvous and docking missions.

  7. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  8. Fission Surface Power Technology Demonstration Unit Test Results

    Science.gov (United States)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

  9. Test Beam Results of a 3D Diamond Detector

    CERN Document Server

    Dunser, Marc

    2015-01-01

    3D pixel technology has been used successfully in the past with silicon detectors for tracking applications. Recently, a first prototype of the same 3D technology has been produced on a chemical vapour deposited single-crystal diamond sensor. This device has been subsequently tested in a beam test at CERN’s SPS accelerator in a beam of 120 GeV protons. Details on the production and results of testbeam data are presented.

  10. An improved method for interpreting API filter press hydraulic conductivity test results

    International Nuclear Information System (INIS)

    Heslin, G.M.; Baxter, D.Y.; Filz, G.M.; Davidson, R.R.

    1997-01-01

    The American Petroleum Institute (API) filter press is frequently used to measure the hydraulic conductivity of soil-bentonite backfill during the mix design process and as part of construction quality controls. However, interpretation of the test results is complicated by the fact that the seepage-induced consolidation pressure varies from zero at the top of the specimen to a maximum value at the bottom of the specimen. An analytical solution is available which relates the stress, compressibility, and hydraulic conductivity in soil consolidated by seepage forces. This paper presents the results of a laboratory investigation undertaken to support application of this theory to API hydraulic conductivity tests. When the API test results are interpreted using seepage consolidation theory, they are in good agreement with the results of consolidometer permeameter tests. Limitations of the API test are also discussed

  11. Containment liner plate anchors and steel embedments test results

    International Nuclear Information System (INIS)

    Chang-Lo, P.L.; Johnson, T.E.; Pfeifer, B.W.

    1977-01-01

    This paper summarizes test data on shear load and deformation capabilities for liner plate line anchors and structural steel embedments in reinforced and prestressed concrete nuclear containments. Reinforced and prestressed nuclear containments designed and constructed in the United States are lined with a minimum of 0.64 cm steel plate. The liner plates are anchored by the use of either studs or structural members (line anchors) which usually run in the vertical direction. This paper will only address line anchors. Static load versus displacement test data is necessary to assure that the design is adequate for the maximum loads. The test program for the liner anchors had the following major objectives: determine load versus displacement data for a variety of anchors considering structural tees and small beams with different weld configurations, from the preceding tests, determine which anchors would lead to an economical and extremely safe design and test these anchors for cyclic loads resulting from thermal fluctuations. Various concrete embeds in the containment and other structures are subjected to loads such as pipe rupture which results in shear. Since many of the loads are transient by nature, it is necessary to know the load-displacement relationship so that the energy absorption can be determined. The test program for the embeds had the following objectives: determine load-displacement relationship for various size anchors from 6.5 cm 2 to 26 cm 2 with maximum capacities of approximately 650 kN; determine the effect of various anchor width-to-thickness ratios for the same shear area

  12. Test results of sodium-water reaction testing in near prototypical LMR steam generator

    International Nuclear Information System (INIS)

    Boardman, C.E.; Hui, M.; Neely, H.H.

    1990-01-01

    An extensive test program has been performed in the United States to investigate the effects of large sodium-water reaction events in LMFBR steam generators. Tests were conducted in the Large Leak Test Rig (LLTR) located at the Energy Technology Engineering Center (ETEC). The program was divided into two phases, Series I and Series II, for the purpose of satisfying near-term and long-term needs. Series II was further subdivided into large and intermediate leak tests. This paper will emphasize the Series II intermediate leak tests and resulting conclusions for steam generator design and operation. 11 figs, 2 tabs

  13. Test emission of uranium hexafluoride in atmosphere. Results interpretation

    International Nuclear Information System (INIS)

    Crabol, B.; Deville-Cavelin, G.

    1989-01-01

    To permit the modelization of gaseous uranium hexafluoride behaviour in atmosphere, a validation test has been executed the 10 April 1987. The experimental conditions, the main results and a comparison with a diffusion model are given in this report [fr

  14. Persian competing word test: Development and preliminary results in normal children

    Directory of Open Access Journals (Sweden)

    Mohammad Ebrahim Mahdavi

    2008-12-01

    Full Text Available Background and Aim: Assessment of central auditory processing skills needs various behavioral tests in format of a test battery. There is a few Persian speech tests for documenting central auditory processing disorders. The purpose of this study was developing a dichotic test formed of one-syllabic words suitable for evaluation of central auditory processing in Persian language children and reporting its preliminary results in a group of normal children.Materials and Methods: Persian words in competing manner test was developed utilizing most frequent monosyllabic words in children storybooks reported in the previous researches. The test was performed at MCL on forty-five normal children (39 right-handed and 6 left-handed aged 5-11 years. The children did not show any obvious problem in hearing, speech, language and learning. Free (n=28 and directed listening (n=17 tasks were investigated.Results: The results show that in directed listening task, there is significant advantage for performance of pre-cued ear relative to opposite side. Right ear advantage is evident in free recall condition. Average performance of the children in directed recall is significantly better than free recall. Average row score of the test increases with the children age.Conclusion: Persian words in competing manner test as a dichotic test, can show major characteristics of dichotic listening and effect of maturation of central auditory system on it in normal children.

  15. The CANopen Controller IP Core: Implementation, Synthesis and Test Results

    Science.gov (United States)

    Caramia, Maurizio; Bolognino, Luca; Montagna, Mario; Tosi, Pietro; Errico, Walter; Bigongiari, Franco; Furano, Gianluca

    2011-08-01

    This paper will describe the implementation and test results of the CANopen Controller IP Core (CCIPC) implemented by Thales Alenia Space and SITAEL Aerospace with the support of ESA in the frame of the EXOMARS Project. The CCIPC is a configurable VHDL implementation of the CANOPEN protocol [1]; it is foreseen to be used as CAN bus slave controller within the EXOMARS Entry Descending and Landing Demonstrato Module (EDM) and Rover Module. The CCIPC features, configuration capability, synthesis and test results will be described and the evidence of the state of maturity of this innovative IP core will be demonstrated.

  16. Pipe rupture test results; 6 in. pipe whip test under BWR LOCA conditions

    International Nuclear Information System (INIS)

    Kurihara, Ryoichi; Yano, Toshikazu; Ueda, Shuzo; Isozaki, Toshikuni; Miyazaki, Noriyuki; Kato, Rokuro; Miyazono, Shohachiro

    1983-02-01

    A series of pipe rupture tests has been performed in JAERI to demonstrate the safety of the primary coolant circuits in the event of pipe rupture, in nuclear power plants. The present report summarizes the results of 6 in. pipe whip tests (RUN 5605, 5606), under BWR LOCA conditions (285 0 C, 6.8 MPa), which were performed in August, 1981. The test pipe is made of Type 304 stainless steel and its outer diameter is 6 in. and its thickness is 11.1 mm. The restraints are made of Type 304 stainless steel and its diameter is 16.0 mm. Two restraints were set on the restraint support with clearance of 100 mm. Overhang length was varied as the parameter in these tests and was 300 mm or 700 mm. The following results are obtained. (1) The deformations of a pipe and restraints are limited effectively by shorter overhang length of 300. However, they become larger when the overhang length is 700 mm, and the pipe deforms especially at the setting point of restraints. (2) Velocity at the free end of pipe becomes about 30 m/sec just after the break. However, velocity at the setting point of restraint becomes about only 4 m/sec just after the break. (3) It seems from the comparison between the 4 in. tests and 6 in. tests that the maximum restraint force of 6 in. tests is about two times as large as that of 4 in. tests. (author)

  17. TEST RESULTS FOR LHC INSERTION REGION DEPOLE MAGNETS

    International Nuclear Information System (INIS)

    MURATORE, J.; JAIN, A.; ANERELLA, M.; COSSOLINO, J.

    2005-01-01

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They are required to produce fields up to 4.14 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, whose construction was very different from the RHIC dipoles, except for the coil design. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality

  18. Using Large Scale Test Results for Pedagogical Purposes

    DEFF Research Database (Denmark)

    Dolin, Jens

    2012-01-01

    The use and influence of large scale tests (LST), both national and international, has increased dramatically within the last decade. This process has revealed a tension between the legitimate need for information about the performance of the educational system and teachers to inform policy......, and the teachers’ and students’ use of this information for pedagogical purposes in the classroom. We know well how the policy makers interpret and use the outcomes of such tests, but we know less about how teachers make use of LSTs to inform their pedagogical practice. An important question is whether...... there is a contradiction between the political system’s use of LST and teachers’ (possible) pedagogical use of LST. And if yes: What is a contradiction based on? This presentation will give some results from a systematic review on how tests have influenced the pedagogical practice. The research revealed many of the fatal...

  19. Results for the Brine Evaporation Bag (BEB) Brine Processing Test

    Science.gov (United States)

    Delzeit, Lance; Flynn, Michael; Fisher, John; Shaw, Hali; Kawashima, Brian; Beeler, David; Howard, Kevin

    2015-01-01

    The recent Brine Processing Test compared the NASA Forward Osmosis Brine Dewatering (FOBD), Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB). This paper reports the results of the BEB. The BEB was operated at 70 deg C and a base pressure of 12 torr. The BEB was operated in a batch mode, and processed 0.4L of brine per batch. Two different brine feeds were tested, a chromic acid-urine brine and a chromic acid-urine-hygiene mix brine. The chromic acid-urine brine, known as the ISS Alternate Pretreatment Brine, had an average processing rate of 95 mL/hr with a specific power of 5kWhr/L. The complete results of these tests will be reported within this paper.

  20. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  1. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  2. MicroCHP: Overview of selected technologies, products and field test results

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Vollrad [Berliner Energieagentur GmbH, Franzoesische Strasse 23, 10117 Berlin (Germany); Klemes, Jiri; Bulatov, Igor [Centre for Process Integration, CEAS, The University of Manchester, P.O. Box 88, M60 1QD Manchester (United Kingdom)

    2008-11-15

    This paper gives an overview on selected microCHP technologies and products with the focus on Stirling and steam machines. Field tests in Germany, the UK and some other EC countries are presented, assessed and evaluated. Test results show the overall positive performance with differences in sectors (domestic vs. small business). Some negative experiences have been received, especially from tests with the Stirling engines and the free-piston steam machine. There are still obstacles for market implementation. Further projects and tests of microCHP are starting in various countries. When positive results will prevail and deficiencies are eliminated, a way to large-scale production and market implementation could be opened. (author)

  3. Tuned Chamber Core Panel Acoustic Test Results

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.

    2016-01-01

    This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.

  4. Results of recent KROTOS FCI tests. Alumina vs. corium melts

    Energy Technology Data Exchange (ETDEWEB)

    Huhtiniemi, I.; Magallon, D.; Hohmann, H. [Commission of the European Communities, Ispra (Italy). Joint Research Center

    1998-01-01

    Recent results from KROTOS fuel-coolant interaction experiments are discussed. Five tests with alumina were performed under highly subcooled conditions, all of these tests resulted in spontaneous steam explosions. Additionally, four tests were performed at low subcooling to confirm, on one hand, the suppression of spontaneous steam explosions under such conditions and, on the other hand, that such a system is still triggerable using an external initiator. The other test parameters in these alumina tests included the melt superheat and the initial pressure. All the tests in the investigated superheat range (150 K - 750 K) produced a steam explosion and no evidence of the explosion suppression by the elevated initial pressure (in the limited range of 0.1 - 0.375 MPa) was observed in the alumina tests. The corium test series include a test with 3 kg of melt under both subcooled and near saturated conditions at ambient pressure. Two additional tests were performed with subcooled water; one test was performed at an elevated pressure of 0.2 MPa with 2.4 kg of melt and another test with 5.1 kg of melt at ambient pressure. None of these tests with corium produced a propagating energetic steam explosion. However, propagating low energy (about twice the energy of the trigger pulse) events were observed. All corium tests produced significantly higher water level swells during the mixing phase than the corresponding alumina tests. Present experimental evidence suggests that the water depletion in the mixing zone suppresses energetic steam explosions with corium melts at ambient pressure and in the present pour geometry. Processes that could produce such a difference in void generation are discussed. (author)

  5. Results from Testing of Two Rotary Percussive Drilling Systems

    Science.gov (United States)

    Kriechbaum, Kristopher; Brown, Kyle; Cady, Ian; von der Heydt, Max; Klein, Kerry; Kulczycki, Eric; Okon, Avi

    2010-01-01

    The developmental test program for the MSL (Mars Science Laboratory) rotary percussive drill examined the e ect of various drill input parameters on the drill pene- tration rate. Some of the input parameters tested were drill angle with respect to gravity and percussive impact energy. The suite of rocks tested ranged from a high strength basalt to soft Kaolinite clay. We developed a hole start routine to reduce high sideloads from bit walk. The ongoing development test program for the IMSAH (Integrated Mars Sample Acquisition and Handling) rotary percussive corer uses many of the same rocks as the MSL suite. An additional performance parameter is core integrity. The MSL development test drill and the IMSAH test drill use similar hardware to provide rotation and percussion. However, the MSL test drill uses external stabilizers, while the IMSAH test drill does not have external stabilization. In addition the IMSAH drill is a core drill, while the MSL drill uses a solid powdering bit. Results from the testing of these two related drilling systems is examined.

  6. Updated Results of Ultrasonic Transducer Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua; Palmer, Joe [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, 38415-3840 (United States); Ramuhalli, Pradeep; Keller, Paul; Montgomery, Robert [Pacific Northwest National Laboratory, 902 Battelle Blvd. Richland, WA, 99354 (United States); Chien, Hual-Te [Argonne National Laboratory, 9700 S. Cass Avenue Argonne, IL, 60439 (United States); Tittmann, Bernhard; Reinhardt, Brian [Pennsylvania State University, 212 Earth and Engr. Sciences Building, University Park, PA, 16802 (United States); Kohse, Gordon [Massachusetts Institute of Technology, 77 Massachusetts Ave. Cambridge, MA 02139 (United States); Rempe, Joy [Rempe and Associates, LLC, 360 Stillwater, Idaho Falls, ID 83404 (United States); Villard, J.F. [Commissariat a l' energie atomique et aux energies alternatives, Centre d' etudes de Cadarache, 13108 Saint-Paul-lez-Durance (France)

    2015-07-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10{sup 21} n/cm{sup 2}. A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET-ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation. (authors)

  7. Test beam results from a scintillating fibers-lead calorimeter

    International Nuclear Information System (INIS)

    Caria, M.

    1991-01-01

    The SpaCal collaboration has built prototypes of lead-scintillating fibers calorimter. The aim is to check predicted performances. Here are briefly mentioned results obtained from prototypes tests in beam of e, π, μ at CERN. Layers 2m long of extruded lead, were equipped with 1mm fibers in an hexagonal geometry. The ratio of scintillator to lead was 1/4. Results are presented on the most appealing features of such a calorimeter: energy resolution, homogeneity, containment and compensation. It is shown, that excellent energy resolution togehter with compensation has been achieved. (orig.)

  8. Influence of test conditions and exposure duration on the result of ecotoxicological tests

    DEFF Research Database (Denmark)

    Rosenkrantz, Rikke Tjørnhøj

    be calculated from results of ecotoxicological tests performed according to internationally approved guidelines, such as from the Organisation for Economic Co-operation and Development (OECD) or International Standardization Organisation (ISO). Such guidelines were originally developed to enable classification......H and exposure duration on the toxicity recorded in tests using four sulfonylurea herbicides (SUs) and the aquatic macrophyte Lemna gibba as study objects. The study showed that changing the physical and chemical test conditions influenced the toxicity of sulfonylurea herbicides towards L. gibba. Lowering...

  9. Commissioning and First Results from the Fermilab Cryomodule Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Harms, Elvin; et al.

    2017-05-01

    A new test stand dedicated to SRF cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.

  10. Estimating Full IM240 Emissions from Partial Test Results: Evidence from Arizona.

    Science.gov (United States)

    Ando, Amy W; Harrington, Winston; McConnell, Virginia

    1999-10-01

    The expense and inconvenience of enhanced-vehicle-emissions testing using the full 240-second dynamometer test has led states to search for ways to shorten the test process. In fact, all states that currently use the IM240 allow some type of fast-pass, usually as early in the test as second 31, and Arizona has allowed vehicles to fast-fail after second 93. While these shorter tests save states millions of dollars in inspection lanes and driver costs, there is a loss of information since test results are no longer comparable across vehicles. This paper presents a methodology for estimating full 240-second results from partial-test results for three pollutants: HC, CO, and NO x . If states can convert all tests to consistent IM240 readings, they will be able to better characterize fleet emissions and to evaluate the impact of inspection and maintenance and other programs on emissions over time. Using a random sample of vehicles in Arizona which received full 240-second tests, we use regression analysis to estimate the relationship between emissions at second 240 and emissions at earlier seconds in the test. We examine the influence of other variables such as age, model-year group, and the pollution level itself on this relationship. We also use the estimated coefficients in several applications. First, we try to shed light on the frequent assertion that the results of the dynamometer test provide guidance for vehicle repair of failing vehicles. Using a probit analysis, we find that the probability that a failing vehicle will pass the test on the first retest is greater the longer the test has progressed. Second, we test the accuracy of our estimates for forecasting fleet emissions from partial-test emissions results in Arizona. We find forecasted fleet average emissions to be very close to the actual fleet averages for light-duty vehicles, but not quite as good for trucks, particularly when NO x emissions are forecast.

  11. Field Lysimeter Test Facility: Second year (FY 1989) test results

    International Nuclear Information System (INIS)

    Campbell, M.D.; Gee, G.W.; Kanyid, M.J.; Rockhold, M.L.

    1990-04-01

    The Record of Decision associated with the Hanford Defense Waste Environmental Impact Statement (53 FR 12449-53) commits to an evaluation of the use of protective barriers placed over near-surface wastes. The barrier must protect against wind and water erosion and limit plant and animal intrusion and infiltration of water. Successful conclusion of this program will yield the necessary protective barrier design for near-surface waste isolation. This report presents results from the second year of tests at the FLTF. The primary objective of testing protective barriers at the FLTF was to measure the water budgets within the various barriers and assess the effectiveness of their designs in limiting water intrusion into the zone beneath each barrier. Information obtained from these measurements is intended for use in refining barrier designs. Four elements of water budget were measured during the year: precipitation, evaporation, storage, and drainage. Run-off, which is a fifth element of a complete water budget, was made negligible by a lip on the lysimeters that protrudes 5 cm above the soil surface to prevent run-off. A secondary objective of testing protective barriers at the FLTF was to refine procedures and equipment to support data collection for verification of the computer model needed for long-term projections of barrier performance. 6 refs

  12. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  13. Test results of a 5 kW fully superconducting homopolar motor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. K. [Woosuk University, Wanju (Korea, Republic of); Park, S. H.; Kim, Y.; Lee, S.; Joo, H. G.; Kim, W. S.; Choi, K. [Korea Polytechnic University,Siheong (Korea, Republic of); Hahm, S. Y. [Electrical Engineering and Science Research Institute,Seoul (Korea, Republic of)

    2013-05-15

    The superconducting Homopolar motor is manufactured and tested. Homopolar motor system is simple and solid as the field coil of the motor is fixed near the stator coil without rotating system. In this paper, a 5 kW fully superconducting homopolar motor which has high temperature superconducting armature and field coils is manufactured and tested in liquid nitrogen. The critical current test results of the used 2G superconducting wire, pancake coil for rotor winding and race-track coils for armature winding are reported. Also, the test result of rotating and operating performance is presented. The operating frequency is to be 5 Hz for low-speed rotating. The developed fully superconducting Homopolar motor is the world's first.

  14. Test results of a 5 kW fully superconducting homopolar motor

    International Nuclear Information System (INIS)

    Lee, J. K.; Park, S. H.; Kim, Y.; Lee, S.; Joo, H. G.; Kim, W. S.; Choi, K.; Hahm, S. Y.

    2013-01-01

    The superconducting Homopolar motor is manufactured and tested. Homopolar motor system is simple and solid as the field coil of the motor is fixed near the stator coil without rotating system. In this paper, a 5 kW fully superconducting homopolar motor which has high temperature superconducting armature and field coils is manufactured and tested in liquid nitrogen. The critical current test results of the used 2G superconducting wire, pancake coil for rotor winding and race-track coils for armature winding are reported. Also, the test result of rotating and operating performance is presented. The operating frequency is to be 5 Hz for low-speed rotating. The developed fully superconducting Homopolar motor is the world's first.

  15. Dimethyl Ether: New Advances in Wear Testing: Theoretical and Experimental Results

    DEFF Research Database (Denmark)

    Sivebæk, Ion Marius; Sorenson, Spencer C; Jakobsen, J.

    2003-01-01

    The issues addressed in this paper are investigation of the wear mechanisms present in the standard lubricity test for diesel oil: The High frequency reciprocating Rig (HFRR). The HFRR is a laboratory wear test using a ball on disk configuration. The result of a test is the wear scar diameter (WSD...... surfaces with long-range elasticity. This last property has enabled the model to correlate well with experimental results. The outcome of the alkane calculations indicates that the longer ones lubricate better than the shorts ones but not necessarily because of viscosity differences. The reason is more...

  16. Summary of microsatellite instability test results from laboratories participating in proficiency surveys: proficiency survey results from 2005 to 2012.

    Science.gov (United States)

    Boyle, Theresa A; Bridge, Julia A; Sabatini, Linda M; Nowak, Jan A; Vasalos, Patricia; Jennings, Lawrence J; Halling, Kevin C

    2014-03-01

    The College of American Pathologists surveys are the largest laboratory peer comparison programs in the world. These programs allow laboratories to regularly evaluate their performance and improve the accuracy of the patient test results they provide. Proficiency testing is offered twice a year to laboratories performing microsatellite instability testing. These surveys are designed to emulate clinical practice, and some surveys have more challenging cases to encourage the refinement of laboratory practices. This report summarizes the results and trends in microsatellite instability proficiency testing from participating laboratories from the inception of the program in 2005 through 2012. We compiled and analyzed data for 16 surveys of microsatellite instability proficiency testing during 2005 to 2012. The number of laboratories participating in the microsatellite instability survey has more than doubled from 42 to 104 during the 8 years analyzed. An average of 95.4% of the laboratories correctly classified each of the survey test samples from the 2005A through 2012B proficiency challenges. In the 2011B survey, a lower percentage of laboratories (78.4%) correctly classified the specimen, possibly because of overlooking subtle changes of microsatellite instability and/or failing to enrich the tumor content of the specimen to meet the limit of detection of their assay. In general, laboratories performed well in microsatellite instability testing. This testing will continue to be important in screening patients with colorectal and other cancers for Lynch syndrome and guiding the management of patients with sporadic colorectal cancer.

  17. Electromagnetic results of the Japanese LCT coil's domestic test

    International Nuclear Information System (INIS)

    Nishi, Masataka; Okuno, Kiyoshi; Takahashi, Yoshikazu; Tsuji, Hiroshi; Ando, Toshinari; Shimamoto, Susumu

    1984-01-01

    The domestic test of the Japanese LCT coil was carried out in 1982. During this test, the coil was charged up to the single coil's 100% state (10.22kA, 6.4T, 106MJ) four times and experienced no quenche. at the 100% charging state, coil stability was tested by using heaters installed in the conductor. A half turn length normal zone (about 5 m) generated by heaters was spontenously disappeared in 2 second. This normalized zone included the highest magnetic field position. The transport current which gives the stable limit is extraporated to be about 12.5kA at 8T by this test result. The dump test was carried out also from the 100% charging state. At that time, about 90% of the coil's stored energy was extracted by the dump resistor and the coil was not damaged. (author)

  18. Frosting and defrosting of air-coils - results from laboratory testing

    Energy Technology Data Exchange (ETDEWEB)

    Fahlen, P

    1997-12-31

    Frosting of air-coils is an important factor in the design and operation of air-source heat pumps, heat recovery ventilators, cooling and refrigeration equipment etc. This report presents results from laboratory testing of two brine-cooled air-coils under frosting conditions. The coils have the same number of plane, continuous fins, 4 tube rows with 12 tubes in each row, tube spacing of 50 mm and fin spacing of 3 and 6 mm respectively. The original purpose of the test program was to compare various possible indicators of coil frosting and to analyze the possible effects of different control strategies on coil capacity and the COP of the system (the analysis will be presented in a separate report). Tests involved inlet air temperatures of -7 and +2 degC, variation of humidity between 70 and 100% RH (including simulated rain), velocities in the range 1 to 4 m/s, and specific cooling loads from 50 to 150 W/m{sup 2}. Test results include variations due to frosting of e.g. cooling capacity, COP, air flow and pressure drop, fan power, air outlet temperature and humidity, coil temperature, frost mass, and frosting time. Results also include the subsequently required defrost time, defrost energy and collected mass of defrost water. The frosting process was interrupted when the air flow had decreased to 30% of the original value with a non-frosted coil. The results clearly show the advantage of demand controlled defrosting with variations in frosting time between 2 h with high humidity/high specific cooling load up to, for practical purposes, infinite frosting times with low humidity/low specific cooling load. The accumulated frost mass during one frosting cycle varied from less than 0.02 kg/m{sup 2} up to approximately 0.4 kg/m{sup 2}. 23 refs, 93 figs, 89 tabs

  19. Frosting and defrosting of air-coils - results from laboratory testing

    Energy Technology Data Exchange (ETDEWEB)

    Fahlen, P.

    1996-12-31

    Frosting of air-coils is an important factor in the design and operation of air-source heat pumps, heat recovery ventilators, cooling and refrigeration equipment etc. This report presents results from laboratory testing of two brine-cooled air-coils under frosting conditions. The coils have the same number of plane, continuous fins, 4 tube rows with 12 tubes in each row, tube spacing of 50 mm and fin spacing of 3 and 6 mm respectively. The original purpose of the test program was to compare various possible indicators of coil frosting and to analyze the possible effects of different control strategies on coil capacity and the COP of the system (the analysis will be presented in a separate report). Tests involved inlet air temperatures of -7 and +2 degC, variation of humidity between 70 and 100% RH (including simulated rain), velocities in the range 1 to 4 m/s, and specific cooling loads from 50 to 150 W/m{sup 2}. Test results include variations due to frosting of e.g. cooling capacity, COP, air flow and pressure drop, fan power, air outlet temperature and humidity, coil temperature, frost mass, and frosting time. Results also include the subsequently required defrost time, defrost energy and collected mass of defrost water. The frosting process was interrupted when the air flow had decreased to 30% of the original value with a non-frosted coil. The results clearly show the advantage of demand controlled defrosting with variations in frosting time between 2 h with high humidity/high specific cooling load up to, for practical purposes, infinite frosting times with low humidity/low specific cooling load. The accumulated frost mass during one frosting cycle varied from less than 0.02 kg/m{sup 2} up to approximately 0.4 kg/m{sup 2}. 23 refs, 93 figs, 89 tabs

  20. Results of aerosol code comparisons with releases from ACE MCCI tests

    International Nuclear Information System (INIS)

    Fink, J.K.; Corradini, M.; Hidaka, A.; Hontanon, E.; Mignanelli, M.A.; Schroedl, E.; Strizhov, V.

    1992-01-01

    Results of aerosol release calculations by six groups from six countries are compared with the releases from ACE MCCI Test L6. The codes used for these calculations included: SOLGASMIX-PV, SOLGASMIX Reactor 1986, CORCON.UW, VANESA 1.01, and CORCON mod2.04/VANESA 1.01. Calculations were performed with the standard VANESA 1.01 code and with modifications to the VANESA code such as the inclusion of various zirconium-silica chemical reactions. Comparisons of results from these calculations were made with Test L6 release fractions for U, Zr, Si, the fission-product elements Te, Ba, Sr, Ce, La, Mo and control materials Ag, In, and Ru. Reasonable agreement was obtained between calculations and Test L6 results for the volatile elements Ag, In and Te. Calculated releases of the low volatility fission products ranged from within an order of magnitude to five orders of magnitude of Test L6 values. Releases were over and underestimated by calculations. Poorest agreements were obtained for Mo and Si

  1. Abnormal ovarian cancer screening test result: women's informational, psychological and practical needs.

    Science.gov (United States)

    Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A

    2007-01-01

    Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.

  2. Experimental results of some cluster tests in NSRR

    International Nuclear Information System (INIS)

    Kobayashi, Shinsho; Ohnishi, Nobuaki; Yoshimura, Tomio; Lussie, W.G.

    1978-01-01

    The NSRR programme is in progress in JAERI using a pulsed reactor to evaluate the behavior of reactor fuels under reactivity accident conditions. This report describes briefly the experimental results and preliminary analysis of two cluster tests. In the cluster configuration of five fuel rods, the power distribution in outer fuel rods are not symmetric due to neutron absorption in central fuel rod. The cladding temperature on the exterior boundaries of the cluster is higher than that in interior. Good agreement was obtained between the calculated and measured cladding temperature histories. In the 3.8$ excess reactivity test, cluster averaged energy deposition of 237 cal/g.UO 2 , cladding melting and deformation were limited to the portions of the fuel rods that were on the exterior boundaries of the cluster. (auth.)

  3. The first operation of the Delphos plant: Test results

    International Nuclear Information System (INIS)

    Sarno, A.; Noviello, G.; Cordisco, S.; Di Paola, L.; Guerra, M.

    1991-09-01

    The data collected during the O and M of the Delphos plant and the testing results are presented and discussed. Together with the maintenance influence on the operation and production of the plant, the various downtime causes are pointed out. An extensive activity has been carried out to investigate the actual behaviour of the photovoltaic generator and the power conditioning unit. The analysis of the experimental results allows to focus on the different causes of loss and suggest some actions to be taken in order to improve the plant efficiency and increase the energy production. (author)

  4. Results from the Dutch speech-in-noise screening test by telephone

    NARCIS (Netherlands)

    Smits, C.H.M.; Houtgast, T.

    2005-01-01

    OBJECTIVE: The objective of the study was to implement a previously developed automatic speech-in-noise screening test by telephone (Smits, Kapteyn, & Houtgast, 2004), introduce it nationwide as a self-test, and analyze the results. DESIGN: The test was implemented on an interactive voice response

  5. Test Beam Results Obtained with the Q4 Prototype

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Benitez, M.; Alberdi, J.; Cerrada, M.; Colino, N.; Daniel, M.; Fouz, M. c.; Marin, J.; Mocholi, J.; Oller, J. C.; Puerta, J.; Romero, L.; Salicio, J. M.

    2000-07-01

    A prototype of the CMS Barrel Muon Detector incorporating all the features of the final chambers was built at CIEMAT using the mass production assembly procedures and tools. The performance of this prototype was studied in a muon test beam at CERN and the results obtained are presented here. (Author)

  6. Test beam results obtained with the Q4 prototype

    International Nuclear Information System (INIS)

    Aguilar-Benitez, M.; Alberdi, J.; Cerrada, M.; Colino, N.; Daniel, M.; Fouz, M.C.; Marin, J.; Mocholi, J.; Oller, J. C.; Puerta, J.; Romero, L.; Salicio, J. M.; Willmott, C.

    2000-10-01

    A prototype of the CMS Barrel Muon Detector incorporating all the features of the final chambers was built at CIEMAT using the mass production assembly procedures and tools. The performance of this prototype was studied in a muon test beam at CERN and the results obtained are presented here. (Author)

  7. Postirradiation examination results for the Irradiation Effects Test 2

    International Nuclear Information System (INIS)

    Ploger, S.A.; Kerwin, D.K.; Croucher, D.W.

    1978-01-01

    This report presents the postirradiation examination results of Test IE-2 in the Irradiation Effects Test Series conducted under the Thermal Fuels Behavior Program. The objectives of this test were to evaluate the influence of previous cladding irradiation and fuel-cladding diametral gap on fuel rod behavior during a power ramp and during film boiling operation. Test IE-2, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed two 0.97-m-long pressurized water reactor type fuel rods fabricated from previously irradiated zircaloy-4 cladding and two similar rods fabricated from unirradiated cladding. The four rods were subjected to a preconditioning period, followed by a power ramp to an average peak rod power of 68 kW/m and steady state operation for one hour at an individual rod coolant mass flux of 4880 kg/s . m 2 . After a flow reduction to 2550 kg/s . m 2 , film boiling occurred on three rods. An additional flow reduction to 2245 kg/s . m 2 produced film boiling on the remaining fuel rod. Maximum time in film boiling was 90 s. None of the four fuel rods failed during the test. Damage caused by film boiling, as characterized by oxidation, oxide spalling, and collapse at fuel pellet interfaces, was found on all four rods. Film boiling regions on these rods showed evidence of fuel melting, fuel centerline void formation, and internal cladding oxidation resulting from fuel-cladding reaction. Effects of fuel-cladding diametral gap and cladding irradiation are summarized. Measured temperatures and metallographically estimated temperatures are compared at several axial fuel rod locations

  8. Radioactive Testing Results in Support of the In-Tank Precipitation Facility - Filtrate Test

    International Nuclear Information System (INIS)

    Hobbs, D.T.

    1998-01-01

    This report documents results investigating the decomposition of excess NaTPB in presence of filtrate from one of the Cycle I Demonstration tests, fulfilling a request by CST Engineering and the ITP Flow Sheet Team

  9. Development of Test-Analysis Models (TAM) for correlation of dynamic test and analysis results

    Science.gov (United States)

    Angelucci, Filippo; Javeed, Mehzad; Mcgowan, Paul

    1992-01-01

    The primary objective of structural analysis of aerospace applications is to obtain a verified finite element model (FEM). The verified FEM can be used for loads analysis, evaluate structural modifications, or design control systems. Verification of the FEM is generally obtained as the result of correlating test and FEM models. A test analysis model (TAM) is very useful in the correlation process. A TAM is essentially a FEM reduced to the size of the test model, which attempts to preserve the dynamic characteristics of the original FEM in the analysis range of interest. Numerous methods for generating TAMs have been developed in the literature. The major emphasis of this paper is a description of the procedures necessary for creation of the TAM and the correlation of the reduced models with the FEM or the test results. Herein, three methods are discussed, namely Guyan, Improved Reduced System (IRS), and Hybrid. Also included are the procedures for performing these analyses using MSC/NASTRAN. Finally, application of the TAM process is demonstrated with an experimental test configuration of a ten bay cantilevered truss structure.

  10. Post-test investigation result on the WWER-1000 fuel tested under severe accident conditions

    International Nuclear Information System (INIS)

    Goryachev, A.; Shtuckert, Yu.; Zwir, E.; Stupina, L.

    1996-01-01

    The model bundle of WWER-type were tested under SFD condition in the out-of-pile CORA installation. The objective of the test was to provide an information on the WWER-type fuel bundles behaviour under severe fuel damage accident conditions. Also it was assumed to compare the WWER-type bundle damage mechanisms with these experienced in the PWR-type bundle tests with aim to confirm a possibility to use the various code systems, worked our for PWR as applied to WWER. In order to ensure the possibility of the comparison of the calculated core degradation parameters with the real state of the tested bundle, some parameters have been measured on the bundle cross-sections under examination. Quantitative parameters of the bundle degradation have been evaluated by digital image processing of the bundle cross-sections. The obtained results are shown together with corresponding results obtained by the other participants of this investigation. (author). 3 refs, 13 figs

  11. VEGETABLE OILS AS SUBSTITUTION FOR DIESEL OIL Test results ...

    African Journals Online (AJOL)

    Test results obtained on a Diesel Engine with direct injection. W. Scheer, Professor ... High kinematic viscosities, high flash points and high ... nozzle and in the combustion chamber. This is ... speed, fuel consumption and exhaust tempera· tures. ... it enters the fuel system of the engine. An one ..... Internal publi- cation of ...

  12. The psychological impact of test results following diagnostic coronary CT angiography.

    Science.gov (United States)

    Devcich, Daniel A; Ellis, Christopher J; Broadbent, Elizabeth; Gamble, Greg; Petrie, Keith J

    2012-11-01

    Coronary computed tomography (CT) angiography is an advanced cardiac imaging test commonly used for diagnosing early signs of ischemic heart disease. Despite its importance in cardiology, little is known about its psychological effect on patients. The present study sought to examine these effects in relation to illness perceptions, cardiac health behavior intentions, and subsequent health behaviors. Forty-five nonacute cardiac patients who were referred for diagnostic coronary CT angiography completed questionnaires prior to testing and following the receipt of test results, at which point illness perceptions and intentions to take cardiac medication, as well as diet and exercise intentions were measured. Exercise and dietary behaviors were measured at follow-up 6 weeks later. Changes on these variables were then compared between patients diagnosed with normal arteries and patients diagnosed with diseased arteries. Compared to positive-testing patients, patients with normal test results reported significant changes toward more positive illness perceptions following testing, with improvements in emotional effect of illness, illness concern, consequences, and personal control of illness. The illness perception of treatment control was seen as more important among positive-testing patients, whereas both groups reported increases in illness coherence. Health behavior intentions (cardiac medication intentions and exercise intentions) increased for positive-testing patients only, as did physical activity at follow-up. Diagnosis-dependent psychological effects can be detected following coronary CT angiography. These effects have important implications for patient health and health care in diagnostic contexts, and the results from this study can be used to guide further research in this area.

  13. FIRST RESULTS FROM OEDOTENSIOMETRIC TESTS

    Directory of Open Access Journals (Sweden)

    Luigi Cavazza

    2008-09-01

    Full Text Available An oedotensiometer was used to examine to examine the behaviour of sieved sample of a swelling soil (a vertisol as well as of the same soils treated with solution of Na+ + Ca2+ to simulate the soil changes from excessive irrigation with brackish water. The oedometer test consisted in an infiltration of water from below through a ceramic porous plate at a feeding pressure of +10 cm water and successive drainage under a depression mostly of -112 cm of water. The rate of water entry as well as the swelling rate of the sample were monitored. Preliminary considerations regards the domains in which the shrinkage curve of a swelling soil is subdivided and make hypothesis on the swelling process expected when the infiltration from below of the sample is applied. The results support the hypothesis that when the water pressure is applied some water enters rather rapidly in the larger structural pores and is followed later by the swelling in the smaller pores, responsible for the basic domain. This first conclusion demonstrates that the assumption of a simultaneous movement of solid and liquid components in the sample, which is the base of most theoretical developments for swelling soils, cannot be accepted for the tested samples. Some cases with water clogging on the sample surface confirm a late final swelling of the soil and permitted to evaluate the hydraulic conductivity of the swollen soil. These manifestations are more evident in sodicated soils. The loading of the sample reduces the swelling of the sample and seems to reduce its permeability. The reduction of the feeding water pressure further reduces the sample swelling. The draining process from saturated soil sample shows that most of the process occurs in the large pores of the structural domain. This gives the possibility to evaluate the water diffusivity coefficient for the structural domain of the sample. In draining the soil with the highest sodication there was a variation of soil volume

  14. Comparison of transient PCRV model test results with analysis

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Belytschko, T.B.

    1979-01-01

    Comparisons are made of transient data derived from simple models of a reactor containment vessel with analytical solutions. This effort is a part of the ongoing process of development and testing of the DYNAPCON computer code. The test results used in these comparisons were obtained from scaled models of the British sodium cooled fast breeder program. The test structure is a scaled model of a cylindrically shaped reactor containment vessel made of concrete. This concrete vessel is prestressed axially by holddown bolts spanning the top and bottom slabs along the cylindrical walls, and is also prestressed circumferentially by a number of cables wrapped around the vessel. For test purposes this containment vessel is partially filled with water, which comes in direct contact with the vessel walls. The explosive charge is immersed in the pool of water and is centrally suspended from the top of the vessel. The tests are very similar to the series of tests made for the COVA experimental program, but the vessel here is the prestressed concrete container. (orig.)

  15. Benchmark Calculations on Halden IFA-650 LOCA Test Results

    International Nuclear Information System (INIS)

    Ek, Mirkka; Kekkonen, Laura; Kelppe, Seppo; Stengaard, J.O.; Josek, Radomir; Wiesenack, Wolfgang; Aounallah, Yacine; Wallin, Hannu; Grandjean, Claude; Herb, Joachim; Lerchl, Georg; Trambauer, Klaus; Sonnenburg, Heinz-Guenther; Nakajima, Tetsuo; Spykman, Gerold; Struzik, Christine

    2010-01-01

    through several blow-downs and heat-ups and reached peak clad temperatures of more than 1000 C. In the second run, where the rod was sufficiently pre-pressurised, ballooning and burst was obtained. The first benchmark consisted of three rounds of code calculations related to IFA-650.3: 1. Pre-test calculations: Participants were provided with information regarding the setup of the Halden LOCA test facility, data from the commissioning runs, and information about the test pin and power conditions to be applied in the execution of the test. 2. Post-test calculations I: In addition to the information from the first round, participants were provided with the in-pile results from the test. 3. Post-test calculations II, unified thermal-hydraulic boundary conditions: Calculations were repeated using a cladding temperature distribution calculated with ATHLET-CD at GRS. Since the test, when executed, did not produce the expected ballooning and fuel relocation, it was decided to continue with a second benchmark using tests 650.4 and 650.5, this time as post-test calculations. The fourth test of the series, IFA-650.4 conducted in April 2006, caused particular attention in the international nuclear community. The fuel used in the experiment had a high burnup, 92 MWd/kgU, and a low pre-test hydrogen content of about 50 ppm. The cladding burst at about 790 deg. C caused a marked temperature increase at the lower end of the segment and a decrease at the upper end, indicating that fuel relocation had occurred. Subsequent gamma scanning showed that approximately 19 cm (40%) of the fuel stack were missing from the upper part of the rod. PIE at the IFE-Kjeller hot cells corroborated this evidence of substantial fuel relocation. This report presents the results of the codes which participated in the various benchmarks. The two main parts, on benchmark I and II, each start with a brief description of the most important experimental data. Then, the code calculation results follow

  16. Experimental Results of OECD-ATLAS A3.1 Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Wook; Kang, Kyung Ho; Bae, Byoung Uhn; Park, Yu Sun; Choi, Nam Hyun; Kim, Kyung Doo; Choi, Ki Yong [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    After the Fukushima accident, design extension conditions (DECs) such as a station black-out (SBO) and a TLOFW attracted a wide international attention in a sense that such high-risk multiple failure accidents should be revisited from a viewpoint of the reinforcement of the 'defense in depth' concept. In particular, a TLOFW event has been considered as one of the typical beyond design basis accident (bDBA) in a safety analysis of the pressurized water reactors. From a conservative point of view, however, failure of the active safety components needs to be considered in the safety analysis. During a TLOFW accident the most effective safety-related active components are the safety injection pumps (SIPs) and the pilot-operated safety relief valves (POSRVs) which are used in a feed and bleed operation. OECD-ATLAS A3.1 test was performed to simulate a TLOFW with additional failures such as partial failure of the SIPs and POSRVs. This test was performed with two temporal phases with an aim of investigating the effect of feed and bleed operation as an accident mitigation measure. Major findings of the A3.1 test are summarized as follows: - Following the termination of the feedwater supply, the SGs became dried out due to the cyclic opening and closing of the MSSVs. However, the coolant discharge from the secondary side of steam generators through MSSVs resulted in removing the decay heat and establishing the natural circulation in the primary system. - A large coolant inventory loss of the primary system through the POSRV during a feed and bleed operation resulted in a reduction of the core collapsed level but the minimum core level was still above the top of the active core. As a result, the excursion of the maximum PCT was not observed.

  17. NNWSI Phase II materials interaction test procedure and preliminary results

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1985-01-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) project is investigating the volcanic tuff beds of Yucca Mountain, Nevada, as a potential location for a high-level radioactive waste repository. This report describes a test method (Phase II) that has been developed to measure the release of radionuclides from the waste package under simulated repository conditions, and provides information on materials interactions that may occur in the repository. The results of 13 weeks of testing using the method are presented, and an analog test is described that investigates the relationship between the test method and expected repository conditions. 9 references, 10 figures, 11 tables

  18. Life-test results on the Zetatron tube, transformer and the tube-transformer assembly

    International Nuclear Information System (INIS)

    Shope, L.A.

    1983-01-01

    In the development of the PFN probe it became evident that some considerable life testing of the neutron tube, high-voltage pulse transformer, and the tube-transformer assembly (TTA) were needed to (1) identify life limiting mechanisms, (2) estimate performance degradation, and (3) provide a data base for end-of-life predictions. Initial results had shown clearly that testing monitored by technicians would be much too costly. Consequently, a computer-controlled and monitored test was developed. This paper describes the test, summarizes the records, and discusses the results. Also presented are early results of actual probe life testing now underway

  19. Results from the 2012 drug and alcohol testing survey : [analysis brief].

    Science.gov (United States)

    2014-12-01

    This report summarizes the results of the 2012 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) who test positive for...

  20. Results from the 2015 Drug and Alcohol Testing Survey : analysis brief.

    Science.gov (United States)

    2017-06-01

    This report summarizes the results of the 2015 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  1. Results from the 2014 drug and alcohol testing survey : analysis brief.

    Science.gov (United States)

    2016-10-01

    This report summarizes the results of the 2014 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  2. Results from the 2016 Drug and Alcohol Testing Survey : Analysis Brief

    Science.gov (United States)

    2018-01-01

    This report summarizes the results of the 2016 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  3. Test Results for CSTR Test 4

    International Nuclear Information System (INIS)

    Lee, D.D.

    2001-01-01

    One of the 3 technologies currently being developed for the Savannah River Salt Waste Processing Program is the Small-Tank Tetraphenylborate Process (STTP). This process uses sodium tetraphenylborate to precipitate and remove radioactive Cs from the waste and monosodium titanate to sorb and remove radioactive Sr and actinides. ORNL is demonstrating this process at the 1:4000 scale using a 20-liter continuous-flow stirred tank reactor (CSTR) system. The primary goal of Test 4 was to verify that the STTP process could achieve and maintain the necessary Cs decontamination while TPB was actively decomposing. Even with TPB being decomposed by the off-normal conditions of this test, the decontaimination factor for 137 Cs obtained for the filtrate from the Slurry Concentrating Tank ranged from 47,000 to 646,000, exceeding the WAC standard

  4. Compatibility of Clinical Manifestation with Skin Prick Test Result and Food Provocation Test in Food Cross Reaction

    OpenAIRE

    Lubis, Azwin; Barlianto, Wisnu; Endaryanto, Anang; Harsono, Ariyanto

    2017-01-01

    Background: Subjective diagnostic test of food allergy is hugely biased, resulting in irrational diet avoidance. Additional objective tools by skin prick test following food provocation test resulting more accurate cause and prevalence on population. Purpose: To evaluate the compatibility of clinical symptoms with skin prick test and provocation test for imunoglobulin E (IgE) mediated food allergy in Dr. Soetomo Hospital Surabaya. Methods: Cross sectional observational analytic study. Patient...

  5. Experimental test results of multi-channel test rig of T1 test section, 5

    International Nuclear Information System (INIS)

    Hino, Ryutaro; Takase, Kazuyuki; Miyamoto, Yoshiaki

    1990-09-01

    Channel blockage test on a fuel column of the high temperature engineering test reactor (HTTR) has been performed under the helium gas atmosphere at a high temperature and a high pressure in order to obtain safety data on flow rate and temperature distributions in the fuel column with the multi-channel test rig of the fuel stack test section (T 1 ) in HENDEL. In the test, one of 12 fuel channels was blockaded to 90% of flow area at the channel inlet. Experimental results showed that the helium gas flow rate in the blockaded channel was 28%∼33% lower than the average flow rate for Reynolds number from 2300 to 14000 in isothermal flow. When simulated fuel rods were heated, the flow rate in the blockaded channel did not decrease down in comparison with the isothermal flow. This is due to that the heat generated in the fuel rods conducts to the other fuel channels in graphite fuel blocks, so that accelerated pressure losses in the fuel channels change with helium gas temperatures. (author)

  6. Effects of different centrifugation conditions on clinical chemistry and Immunology test results.

    Science.gov (United States)

    Minder, Elisabeth I; Schibli, Adrian; Mahrer, Dagmar; Nesic, Predrag; Plüer, Kathrin

    2011-05-10

    The effect of centrifugation time of heparinized blood samples on clinical chemistry and immunology results has rarely been studied. WHO guideline proposed a 15 min centrifugation time without citing any scientific publications. The centrifugation time has a considerable impact on the turn-around-time. We investigated 74 parameters in samples from 44 patients on a Roche Cobas 6000 system, to see whether there was a statistical significant difference in the test results among specimens centrifuged at 2180 g for 15 min, at 2180 g for 10 min or at 1870 g for 7 min, respectively. Two tubes with different plasma separators (both Greiner Bio-One) were used for each centrifugation condition. Statistical comparisons were made by Deming fit. Tubes with different separators showed identical results in all parameters. Likewise, excellent correlations were found among tubes to which different centrifugation conditions were applied. Fifty percent of the slopes lay between 0.99 and 1.01. Only 3.6 percent of the statistical tests results fell outside the significance level of p < 0.05, which was less than the expected 5%. This suggests that the outliers are the result of random variation and the large number of statistical tests performed. Further, we found that our data are sufficient not to miss a biased test (beta error) with a probability of 0.10 to 0.05 in most parameters. A centrifugation time of either 7 or 10 min provided identical test results compared to the time of 15 min as proposed by WHO under the conditions used in our study.

  7. Summary of results from sodium-heated steam generator test program

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, J S

    1975-07-01

    A 28 MWt sodium-heated steam generator test unit developed and fabricated by Atomics International was operated in the Sodium Component Test Installation. The SCTI is located at the Liquid Metal Engineering Center which is operated for the Atomic Energy Commission by Atomics International, Reviewed in this paper are the results of the test operations and the findings of the post-test examination of the module. Testing was performed to assure the mechanical integrity of the unit over a wide range of simulated plant operating conditions and to develop a variety of performance data. Specific tests conducted included preheat, vibration, startup-shutdown, pressurization, steady state and parametric performance mapping, endurance, simulated leak injection, low- flow stability and simulated plant transients. (author)

  8. Seismic II over I Drop Test Program results and interpretation

    International Nuclear Information System (INIS)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the open-quotes sourcesclose quotes and open-quotes targetsclose quotes requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources

  9. Seismic II over I Drop Test Program results and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the {open_quotes}sources{close_quotes} and {open_quotes}targets{close_quotes} requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources.

  10. Seismic II over I Drop Test Program results and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the [open quotes]sources[close quotes] and [open quotes]targets[close quotes] requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources.

  11. TID Test Results for 4th Generation iPad(TradeMark)

    Science.gov (United States)

    Guertin, S. M.; Allen, G. R.; McClure, S. S.; LaBel, K. A.

    2013-01-01

    TID testing of 4th generation iPads is reported. Of iPad subsystems, results indicate that the charging circuitry and display drivers fail at lowest TID levels. Details of construction are investigated for additional testing of components.

  12. FFTF thermal-hydraulic testing results affecting piping and vessel component design in LMFBR's

    International Nuclear Information System (INIS)

    Stover, R.L.; Beaver, T.R.; Chang, S.C.

    1983-01-01

    The Fast Flux Test Facility completed four years of pre-operational testing in April 1982. This paper describes thermal-hydraulic testing results from this period which impact piping and vessel component design in LMFBRs. Data discussed are piping flow oscillations, piping thermal stratification and vessel upper plenum stratification. Results from testing verified that plant design limits were met

  13. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  14. Preliminary Results of Testing of Flow Effects on Evaporator Scaling

    Energy Technology Data Exchange (ETDEWEB)

    Hu, M.Z.

    2002-02-15

    This investigation has focused on the effects of fluid flow on solids deposition from solutions that simulate the feed to the 2H evaporator at the Savannah River Site. Literature studies indicate that the fluid flow (or shear) affects particle-particle and particle-surface interactions and thus the phenomena of particle aggregation in solution and particle deposition (i.e., scale formation) onto solid surfaces. Experimental tests were conducted with two configurations: (1) using a rheometer to provide controlled shear conditions and (2) using controlled flow of reactive solution through samples of stainless steel tubing. All tests were conducted at 80 C and at high silicon and aluminum concentrations, 0.133 M each, in solutions containing 4 M sodium hydroxide and 1 A4 each of sodium nitrate and sodium nitrite. Two findings from these experiments are important for consideration in developing approaches for reducing or eliminating evaporator scaling problems: (1) The rheometer tests suggested that for the conditions studied, maximum solids deposition occurs at a moderate shear rate, approximately 12 s{sup -1}. That value is expected to be on the order of shear rates that will occur in various parts of the evaporator system; for instance, a 6 gal/min single-phase liquid flow through the 2-in. lift or gravity drain lines would result in a shear rate of approximately 16 s{sup -1}. These results imply that engineering approaches aimed at reducing deposits through increased mixing would need to generate shear near all surfaces significantly greater than 12 s{sup -1}. However, further testing is needed to set a target value for shear that is applicable to evaporator operation. This is because the measured trend is not statistically significant at the 95% confidence interval due to variability in the results. In addition, testing at higher temperatures and lower concentrations of aluminum and silicon would more accurately represent conditions in the evaporator. Without

  15. Expert Knowledge Influences Decision-Making for Couples Receiving Positive Prenatal Chromosomal Microarray Testing Results.

    Science.gov (United States)

    Rubel, M A; Werner-Lin, A; Barg, F K; Bernhardt, B A

    2017-09-01

    To assess how participants receiving abnormal prenatal genetic testing results seek information and understand the implications of results, 27 US female patients and 12 of their male partners receiving positive prenatal microarray testing results completed semi-structured phone interviews. These interviews documented participant experiences with chromosomal microarray testing, understanding of and emotional response to receiving results, factors affecting decision-making about testing and pregnancy termination, and psychosocial needs throughout the testing process. Interview data were analyzed using a modified grounded theory approach. In the absence of certainty about the implications of results, understanding of results is shaped by biomedical expert knowledge (BEK) and cultural expert knowledge (CEK). When there is a dearth of BEK, as in the case of receiving results of uncertain significance, participants rely on CEK, including religious/spiritual beliefs, "gut instinct," embodied knowledge, and social network informants. CEK is a powerful platform to guide understanding of prenatal genetic testing results. The utility of culturally situated expert knowledge during testing uncertainty emphasizes that decision-making occurs within discourses beyond the biomedical domain. These forms of "knowing" may be integrated into clinical consideration of efficacious patient assessment and counseling.

  16. Supercritical CO2 test loop operation and first test results

    International Nuclear Information System (INIS)

    Wright, Steven A.; Pickard, Paul S.

    2009-01-01

    The DOE Office of Nuclear Energy is investigating advanced Brayton cycles for use with next generation nuclear power plants. The focus of this work is on the supercritical CO 2 Brayton cycle which has the potential for high efficiency, and for reduced capital costs due to very compact turbomachinery. Sandia has fabricated and is operating a supercritical CO 2 (S-CO 2 ) test loop to investigate the key technology issues associated with this cycle. This loop is part of a multi-year phased development program to develop a megawatt (MW) class closed S-CO 2 Brayton cycle to demonstrate the applicability of this cycle for DOE Gen-IV program. The current loop has been configured as both a compression loop and as simple heated but unrecuperated Brayton cycle. A second split-flow or re-compression Brayton cycle is currently under development that will use approximately 1 MW of heat to run the Brayton cycle. Early configurations of this split-flow Brayton cycle will be operational later this fiscal year. The key issues for this cycle include the fundamental issues of compressor fluid performance and system control near the critical point, but also the supporting technology issues of bearings, sealing technologies, and rotor windage losses which are also essential to achieving efficiency and cost objectives. These tests are providing the first measurements and information on these key supercritical CO 2 power conversion systems questions. Important data for all these issues has been obtained. This report presents the major results of the testing by showing and comparing the measured compressor performance map with the predicted performance. The compression loop uses a ∼50 kWe motor driven compressor to spin a 37 mm OD compressor at design speeds up to 75,000 rpm with a pressure ratio of 1.8 and a flow rate of 3.53 kg/s for a compressor inlet condition of 305.3 K and 7690 kPa. The most recent configuration of this loop has added a small turbine and 260 kW of heater power is

  17. The meaning of diagnostic test results: A spreadsheet for swift data analysis

    International Nuclear Information System (INIS)

    MacEneaney, Peter M.; Malone, Dermot E.

    2000-01-01

    AIMS: To design a spreadsheet program to: (a) analyse rapidly diagnostic test result data produced in local research or reported in the literature; (b) correct reported predictive values for disease prevalence in any population; (c) estimate the post-test probability of disease in individual patients. MATERIALS AND METHODS: Microsoft Excel TM was used. Section A: a contingency (2 x 2) table was incorporated into the spreadsheet. Formulae for standard calculations [sample size, disease prevalence, sensitivity and specificity with 95% confidence intervals, predictive values and likelihood ratios (LRs)] were linked to this table. The results change automatically when the data in the true or false negative and positive cells are changed. Section B: this estimates predictive values in any population, compensating for altered disease prevalence. Sections C-F: Bayes' theorem was incorporated to generate individual post-test probabilities. The spreadsheet generates 95% confidence intervals, LRs and a table and graph of conditional probabilities once the sensitivity and specificity of the test are entered. The latter shows the expected post-test probability of disease for any pre-test probability when a test of known sensitivity and specificity is positive or negative. RESULTS: This spreadsheet can be used on desktop and palmtop computers. The MS Excel TM version can be downloaded via the Internet from the URL ftp://radiography.com/pub/Rad-data99.xls CONCLUSION: A spreadsheet is useful for contingency table data analysis and assessment of the clinical meaning of diagnostic test results. MacEneaney, P.M., Malone, D.E. (2000)

  18. Postirradiation examination results for the Irradiation Effects Scoping Test 2

    International Nuclear Information System (INIS)

    Mehner, A.S.

    1977-01-01

    The postirradiation examination results are reported for two rods from the second scoping test (IE-ST-2) of the Nuclear Regulatory Commission Irradiation Effects Program. The rods were irradiated in the in-pile test loop of the Power Burst Facility at the Idaho National Engineering Laboratory. Rod IE-005 was fabricated from fresh fuel and cladding previously irradiated in the Saxton Reactor. Rod IE-006, fabricated from fresh fuel and unirradiated cladding, was equipped with six developmental cladding surface thermocouples. The rods were preconditioned, power ramped, and then subjected to film boiling operation. The performance of the rods and the developmental thermocouples are evaluated from the post irradiation examination results. The effects of prior irradiation damage in cladding are discussed in relation to fuel rod behavior during a power ramp and subsequent film boiling operation

  19. 78 FR 6400 - Results of FAA Nitrous Oxide BLEVE Characterization Testing

    Science.gov (United States)

    2013-01-30

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Results of FAA Nitrous Oxide BLEVE Characterization Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of public... FAA sponsored testing of nitrous oxide (N 2 O) characteristics. Nitrous oxide is an important oxidizer...

  20. Wellbore inertial navigation system (WINS) software development and test results

    Energy Technology Data Exchange (ETDEWEB)

    Wardlaw, R. Jr.

    1982-09-01

    The structure and operation of the real-time software developed for the Wellbore Inertial Navigation System (WINS) application are described. The procedure and results of a field test held in a 7000-ft well in the Nevada Test Site are discussed. Calibration and instrumentation error compensation are outlined, as are design improvement areas requiring further test and development. Notes on Kalman filtering and complete program listings of the real-time software are included in the Appendices. Reference is made to a companion document which describes the downhole instrumentation package.

  1. Experimental Results of Integrated Refrigeration and Storage System Testing

    Science.gov (United States)

    Notardonato, W. U.; Johnson, W. L.; Jumper, K.

    2009-01-01

    Launch operations engineers at the Kennedy Space Center have identified an Integrated Refrigeration and Storage system as a promising technology to reduce launch costs and enable advanced cryogenic operations. This system uses a close cycle Brayton refrigerator to remove energy from the stored cryogenic propellant. This allows for the potential of a zero loss storage and transfer system, as well and control of the state of the propellant through densification or re-liquefaction. However, the behavior of the fluid in this type of system is different than typical cryogenic behavior, and there will be a learning curve associated with its use. A 400 liter research cryostat has been designed, fabricated and delivered to KSC to test the thermo fluid behavior of liquid oxygen as energy is removed from the cryogen by a simulated DC cycle cryocooler. Results of the initial testing phase focusing on heat exchanger characterization and zero loss storage operations using liquid oxygen are presented in this paper. Future plans for testing of oxygen densification tests and oxygen liquefaction tests will also be discussed. KEYWORDS: Liquid Oxygen, Refrigeration, Storage

  2. Estimation of AUC or Partial AUC under Test-Result-Dependent Sampling.

    Science.gov (United States)

    Wang, Xiaofei; Ma, Junling; George, Stephen; Zhou, Haibo

    2012-01-01

    The area under the ROC curve (AUC) and partial area under the ROC curve (pAUC) are summary measures used to assess the accuracy of a biomarker in discriminating true disease status. The standard sampling approach used in biomarker validation studies is often inefficient and costly, especially when ascertaining the true disease status is costly and invasive. To improve efficiency and reduce the cost of biomarker validation studies, we consider a test-result-dependent sampling (TDS) scheme, in which subject selection for determining the disease state is dependent on the result of a biomarker assay. We first estimate the test-result distribution using data arising from the TDS design. With the estimated empirical test-result distribution, we propose consistent nonparametric estimators for AUC and pAUC and establish the asymptotic properties of the proposed estimators. Simulation studies show that the proposed estimators have good finite sample properties and that the TDS design yields more efficient AUC and pAUC estimates than a simple random sampling (SRS) design. A data example based on an ongoing cancer clinical trial is provided to illustrate the TDS design and the proposed estimators. This work can find broad applications in design and analysis of biomarker validation studies.

  3. Test results on reuse of reclaimed shower water - A summary

    Science.gov (United States)

    Verostko, Charles E.; Garcia, Rafael; Sauer, Richard; Reysa, Richard P.; Linton, Arthur T.

    1989-01-01

    Results are presented from tests to evaluate a microgravity whole body shower and waste water recovery system design for possible use on the Space Station. Several water recovery methods were tested, including phase change distillation, a thermoelectric hollow fiber membrane evaporation subsystem, and a reverse osmosis dynamic membrane system. Consideration is given to the test hardware, the types of soaps evaluated, the human response to showering with reclaimed water, chemical treatment for microbial control, the procedures for providing hygienic water, and the quality of water produced by the systems. All three of the waste water recovery systems tested successfully produced reclaimed water for reuse.

  4. Creep in rock salt with temperature. Testing methods and results

    International Nuclear Information System (INIS)

    Charpentier, J.P.; Berest, P.

    1985-01-01

    The growing interest shown in the delayed behaviour of rocks at elevated temperature has led the Solid Mechanics Laboratory to develop specific equipment designed for creep tests. The design and dimensioning of these units offer the possibility of investigating a wide range of materials. The article describes the test facilities used (uni-axial and tri-axial creep units) and presents the experimental results obtained on samples of Bresse salt [fr

  5. 10 CFR 707.13 - Medical review of results of tests for illegal drug use.

    Science.gov (United States)

    2010-01-01

    ... another test, performed by the gas chromatography/mass spectrometry method (GC/MS). This procedure is... 10 Energy 4 2010-01-01 2010-01-01 false Medical review of results of tests for illegal drug use... Procedures § 707.13 Medical review of results of tests for illegal drug use. (a) All test results shall be...

  6. Test OPTRAN 1-1 results

    International Nuclear Information System (INIS)

    Martinson, Z.R.

    1982-01-01

    The objective of the OPT 1-1 Test Series was to evaluate the extent of damage and the threshold for failure during simulated BWR anticipated transients. Four power transient tests with progressively higher power levels were performed with preirradiated fuel rods at power ramp rates as high as 550 kW/m per second. Six separately shrouded fuel rods fabricated by the General Electric Co., and preirradiated in the Monticello BWR to burnups of about 5000 to 23,000 MWd/t were tested, four at a time. Four of the fuel rods were of typical GE 8 x 8 design, except for fuel length (0.75 m). Two of the rods included design modifications to improve their PCI-resistant characteristics. A lengthy fuel conditioning preceded the transient testing of the fuel rods

  7. Operational statistical analysis of the results of computer-based testing of students

    Directory of Open Access Journals (Sweden)

    Виктор Иванович Нардюжев

    2018-12-01

    Full Text Available The article is devoted to the issues of statistical analysis of results of computer-based testing for evaluation of educational achievements of students. The issues are relevant due to the fact that computerbased testing in Russian universities has become an important method for evaluation of educational achievements of students and quality of modern educational process. Usage of modern methods and programs for statistical analysis of results of computer-based testing and assessment of quality of developed tests is an actual problem for every university teacher. The article shows how the authors solve this problem using their own program “StatInfo”. For several years the program has been successfully applied in a credit system of education at such technological stages as loading computerbased testing protocols into a database, formation of queries, generation of reports, lists, and matrices of answers for statistical analysis of quality of test items. Methodology, experience and some results of its usage by university teachers are described in the article. Related topics of a test development, models, algorithms, technologies, and software for large scale computer-based testing has been discussed by the authors in their previous publications which are presented in the reference list.

  8. Ordering molecular genetic tests and reporting results: practices in laboratory and clinical settings.

    Science.gov (United States)

    Lubin, Ira M; Caggana, Michele; Constantin, Carolyn; Gross, Susan J; Lyon, Elaine; Pagon, Roberta A; Trotter, Tracy L; Wilson, Jean Amos; McGovern, Margaret M

    2008-09-01

    Previous studies have suggested that patient care may be compromised as a consequence of poor communication between clinicians and laboratory professionals in cases in which molecular genetic test results are reported. To understand better the contributing factors to such compromised care, we investigated both pre- and postanalytical processes using cystic fibrosis mutation analysis as our model. We found that although the majority of test requisition forms requested patient/family information that was necessary for the proper interpretation of test results, in many cases, these data were not provided by the individuals filling out the forms. We found instances in which result reports for simulated diagnostic testing described individuals as carriers where only a single mutation was found with no comment pertaining to a diagnosis of cystic fibrosis. Similarly, reports based on simulated scenarios for carrier testing were problematic when no mutations were identified, and the patient's race/ethnicity and family history were not discussed in reference to residual risk of disease. Remarkably, a pilot survey of obstetrician-gynecologists revealed that office staff, including secretaries, often helped order genetic tests and reported test results to patients, raising questions about what efforts are undertaken to ensure personnel competency. These findings are reviewed in light of what efforts should be taken to improve the quality of test-ordering and result-reporting practices.

  9. Postirradiation examination results for the Irradiation Effects Test IE-5

    International Nuclear Information System (INIS)

    Cook, T.F.; Ploger, S.A.; Hobbins, R.R.

    1978-03-01

    The results are presented of the postirradiation examination of four pressurized water reactor type fuel rods which were tested in-pile under a fast power ramp and film boiling operation during Irradiation Effects (IE) Test 5. The major objectives of this test were to evaluate the effects of simulated fission products on fuel rod behavior during a fast power ramp, to determine the effects of high initial internal pressure on a fuel rod during film boiling, and to assess fuel rod property changes that occur during film boiling in a fuel rod with previously irradiated cladding. The overall condition of the rods and changes that occurred in fuel and cladding as a result of the power ramp and film boiling operation, as determined from the postirradiation examination, are reported and analyzed. Effects of the simulated fission products on fuel rod behavior during a power ramp are discussed. The effect of high internal pressure on rod behavior during film boiling is evaluated. Cladding temperatures are estimated at various axial and circumferential locations. Cladding embrittlement by oxidation is also assessed

  10. Cassini RTG acceptance test results and RTG performance on Galileo and Ulysses

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1997-01-01

    Flight acceptance testing has been completed for the RTGs to be used on the Cassini spacecraft which is scheduled for an October 6, 1997 launch to Saturn. The acceptance test program includes vibration tests, magnetic field measurements, properties (weight and c.g.) and thermal vacuum test. This paper presents The thermal vacuum test results. Three RTGs are to be used, F-2, F-6, and F-7. F-5 is tile back-up RTG, as it was for the Galileo and Ulysses missions launched in 1989 and 1990, respectively. RTG performance measured during the thermal vacuum tests carried out at die Mound Laboratory facility met all specification requirements. Beginning of mission (BOM) and end of mission (EOM) power predictions have been made based on than tests results. BOM power is predicted to be 888 watts compared to the minimum requirement of 826 watts. Degradation models predict the EOM power after 16 years is to be 640 watts compared to a minimum requirement of 596 watts. Results of small scale module tests are also showing. The modules contain couples from the qualification and flight production runs. The tests have exceeded 28,000 hours (3.2 years) and are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. All test results indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of over five percent are predicted. Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Telemetry data are also shown for the RTG on the Ulysses spacecraft which completed its planned mission in 1995 and is now in the extended mission

  11. Cassini RTG acceptance test results and RTG performance on Galileo and Ulysses

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1997-01-01

    Flight acceptance testing has been completed for the RTGs to be used on the Cassini spacecraft which is scheduled for an October 6, 1997 launch to Saturn. The acceptance test program includes vibration tests, magnetic field measurements, mass properties (weight and c.g.) and thermal vacuum test. This paper presents the thermal vacuum test results. Three RTGs are to be used, F-2, F-6, and F-7. F-5 is the backup RTG, as it was for the Galileo and Ulysses missions launched in 1989 and 1990, respectively. RTG performance measured during the thermal vacuum tests carried out at the Mound Laboratory facility met all specification requirements. Beginning of mission (BOM) and end of mission (EOM) power predictions have been made based on these tests results. BOM power is predicted to be 888 watts compared to the minimum requirement of 826 watts. Degradation models predict the EOM power after 16 years is to be 640 watts compared to a minimum requirement of 596 watts. Results of small scale module tests are also shown. The modules contain couples from the qualification and flight production runs. The tests have exceeded 28,000 hours (3.2 years) and are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. All test results indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of over 5% are predicted. Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Telemetry data are also shown for the RTG on the Ulysses spacecraft which completed its planned mission in 1995 and is now in the extended mission

  12. Results from annual testing of ARECO cesium capsules from 1990-1994

    Energy Technology Data Exchange (ETDEWEB)

    Lundeen, J.E.

    1994-10-01

    The purpose of this report is to compile the results of the cesium capsule inspections and testing at the Applied Radiant Energy Corporation (ARECO) facility in Lynchburg, VA, performed in 1990, 1991, 1992, 1993, and 1994. The 25 cesium capsules at the ARECO facility were visually identified and clunk tested. A Go/No Go gauge test was required for capsules failing the clunk test. A visual inspection of capsules was required for the initial testing (1990). All 25 capsules passed the inspections and testing each year.

  13. Comparison of Estrogen Receptor Assay Results from Pathology Reports with Results from Central Laboratory Testing: Implications for Population-Based Studies of Breast Cancer

    Science.gov (United States)

    Collins, LC; Marotti, J; Baer, HJ; Deitz, AC; Colditz, GA; Tamimi, RM

    2014-01-01

    Population-based studies of women with breast cancer commonly utilize information culled from pathology reports rather than central pathology review. The reliability of this information, particularly with regard to tumor biomarker results, is of concern. To address this, we evaluated the concordance between estrogen receptor (ER) results as determined from the original pathology reports and ER results obtained on the same specimens following testing in a single laboratory. Tissue microarrays (TMAs) were constructed from paraffin blocks of 3,167 breast cancers that developed in women enrolled in the Nurses’ Health Study. ER immunostains were performed on all TMA sections in single run. Results of ER immunostains performed on the TMA sections were compared with ER assay results abstracted from pathology reports. Among 1,851 cases of invasive breast cancer in which both ER results from pathology reports and central ER test results were available, the reported ER status and the ER status as determined from immunostains on TMAs were in agreement in 1,651 cases (87.3 %; kappa value 0.64, ppathology reports is a reasonable, albeit imperfect, alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer. PMID:18230800

  14. Results from a Test Fixture for button BPM Trapped Mode Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cameron,P.; Bacha, B.; Blednykh, A.; Pinayev, I.; Singh, O.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1) Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.

  15. Large coil task and results of testing US coils

    International Nuclear Information System (INIS)

    Haubenreich, P.N.

    1986-01-01

    The United States, EURATOM, Japan, and Switzerland have collaborated since 1978 in development of superconducting toroidal field coils for fusion reactor applications. The United States provided a test facility nd three coils; the other participants, one coil each. All coils have the same interface dimensions and performance requirements (stable at 8 T), but internal design was decided by each team. Two US coil teams chose bath-cooled NbTi, 10-kA conductors. One developed a Nb 3 Sn conductor, cooled by internal flow, rated at 18 kA. All US coils have diagnostic instrumentation and imbedded heaters that enable stability tests and simulated nuclear heating experiments. In single-coil tests, each coil operated at full current in self-field (6.4 T). In six-coil tests that began in July 1986, one US coil and the Japanese coil hve been successfully operated at full current at 8 T. The other coils have operated as background coils while awaiting their turn as test coil. Coil tests have been informative and results gratifying. The facility has capably supported coil testing and its operation has provided information that will be useful in designing future fusion systems. Coil capabilities beyond nominal design points will be determined

  16. Preliminary irradiation test results from the Yankee Atomic Electric Company reactor vessel test irradiation program

    International Nuclear Information System (INIS)

    Biemiller, E.C.; Fyfitch, S.; Campbell, C.A.

    1993-01-01

    The Yankee Atomic Electric Company test irradiation program was implemented to characterize the irradiation response of representative Yankee Rowe reactor vessel beltline plate materials and to remove uncertainties in the analysis of existing irradiation data on the Yankee Rowe reactor vessel steel. Plate materials each containing 0.24 w/o copper, but different nickel contents at 0.63 w/o and 0.19 w/o, were heat treated to simulate the Yankee vessel heat treatment (austenitized at 1800 deg F) and to simulate Regulatory Guide 1.99 database materials (austenitized at 1600 deg. F). These heat treatments produced different microstructures so the effect of microstructure on irradiation damage sensitivity could be tested. Because the nickel content of the test plates varied and the copper level was constant, the effect of nickel on irradiation embrittlement was also tested. Correlation monitor material, HSST-02, was included in the program to benchmark the Ford Nuclear Reactor (U. of Michigan Test Reactor) which had never been used for this type of irradiation program. Materials taken from plate surface locations (vs. 1/4T) were included to test whether or not the improved toughness properties of the plate surface layer, resulting from the rapid quench, is maintained after irradiation. If the improved properties are maintained, pressurized thermal shock calculations could utilize this margin. Finally, for one experiment, irradiations were conducted at two irradiation temperatures (500 deg. F and 550 deg. F) to determine the effect of irradiation temperature on embrittlement. The preliminary results of the irradiation program show an increase in T 30 shift of 69 deg. F for a decrease in irradiation temperature of 50 deg. F. The results suggest that for nickel bearing steels, the superior toughness of plate surface material is maintained after irradiation and for the copper content tested, nickel had no apparent effect on irradiation response. No apparent microstructure

  17. Results from the Cooler and Lead Tests

    International Nuclear Information System (INIS)

    Green, Michael A.

    2010-01-01

    The report presents the results of testing MICE spectrometer magnet current leads on a test apparatus that combines both the copper leads and the high temperature superconducting (HTS) leads with a single Cryomech PT415 cooler and liquid helium tank. The current is carried through the copper leads from 300 K to the top of the HTS leads. The current is then carried through the HTS leads to a feed-through from the vacuum space to the inside of a liquid helium tank. The experiment allows one to measure the performance of both cooler stages along with the performance of the leads. While the leads were powered we measured the voltage drops through the copper leads, through the HTS leads, through spliced to the feed-through, through the feed-through and through the low-temperature superconducting loop that connects one lead to the other. Measurements were made using the leads that were used in spectrometer magnet 1A and spectrometer magnet 2A. These are the same leads that were used for Superbend and Venus magnets at LBNL. The IL/A for these leads was 5.2 x 10 6 m -1 . The leads turned out to be too long. The same measurements were made using the leads that were installed in magnet 2B. The magnet 2B leads had an IL/A of 3.3 x 10 6 A m -1 . This report discusses the cooler performance and the measured electrical performance of the lead circuit that contains the copper leads and the superconducting leads. All of the HTS leads that were installed in magnet 2B were current tested using this apparatus.

  18. Interpreting Statistical Significance Test Results: A Proposed New "What If" Method.

    Science.gov (United States)

    Kieffer, Kevin M.; Thompson, Bruce

    As the 1994 publication manual of the American Psychological Association emphasized, "p" values are affected by sample size. As a result, it can be helpful to interpret the results of statistical significant tests in a sample size context by conducting so-called "what if" analyses. However, these methods can be inaccurate…

  19. Study of influence of an experiment scale on cylinder test results

    Directory of Open Access Journals (Sweden)

    Waldemar A. Trzciński

    2014-03-01

    Full Text Available In the work, influence of a scale of experiment on the results of cylindrical test used todetermine the acceleration capabilities of explosives was analyzed. Explosives used in ammunition(TNT, hexogen and explosives for civil purpose (ammonals were selected for testing. Copper tubeswith different diameters and wall thickness were used. Conclusions are drawn regarding the advisabilityof increasing or decreasing the scale of the cylinder test.[b]Keywords[/b]: explosives, acceleration ability, cylinder test

  20. Fuel integrity project: analysis of light water reactor fuel rods test results

    International Nuclear Information System (INIS)

    Dallongeville, M.; Werle, J.; McCreesh, G.

    2004-01-01

    BNFL Nuclear Sciences and Technology Services and COGEMA LOGISTICS started in the year 2000 a joint project known as FIP (Fuel Integrity Project) with the aim of developing realistic methods by which the response of LWR fuel under impact accident conditions could be evaluated. To this end BNFL organised tests on both unirradiated and irradiated fuel pin samples and COGEMA LOGISTICS took responsibility for evaluating the test results. Interpretation of test results included simple mechanical analysis as well as simulation by Finite Element Analysis. The first tests that were available for analysis were an irradiated 3 point bending commissioning trial and a lateral irradiated hull compression test, both simulating the loading during a 9 m lateral regulatory drop. The bending test span corresponded roughly to a fuel pin intergrid distance. The outcome of the test was a failure starting at about 35 mm lateral deflection and a few percent of total deformation. Calculations were carried out using the ANSYS code employing a shell and brick model. The hull lateral compaction test corresponds to a conservative compression by neighbouring pins at the upper end of the fuel pin. In this pin region there are no pellets inside. The cladding broke initially into two and later into four parts, all of which were rather similar. Initial calculations were carried out with LS-DYNA3D models. The models used were optimised in meshing, boundary conditions and material properties. The calculation results compared rather well with the test data, in particular for the detailed ANSYS approach of the 3 point bending test, and allowed good estimations of stresses and deformations under mechanical loading as well as the derivation of material rupture criteria. All this contributed to the development of realistic numerical analysis methods for the evaluation of LWR fuel rod behaviour under both normal and accident transport conditions. This paper describes the results of the 3 point bending

  1. Fuel integrity project: analysis of light water reactor fuel rods test results

    Energy Technology Data Exchange (ETDEWEB)

    Dallongeville, M.; Werle, J. [COGEMA Logistics (AREVA Group) (France); McCreesh, G. [BNFL Nuclear Sciences and Technology Services (United Kingdom)

    2004-07-01

    BNFL Nuclear Sciences and Technology Services and COGEMA LOGISTICS started in the year 2000 a joint project known as FIP (Fuel Integrity Project) with the aim of developing realistic methods by which the response of LWR fuel under impact accident conditions could be evaluated. To this end BNFL organised tests on both unirradiated and irradiated fuel pin samples and COGEMA LOGISTICS took responsibility for evaluating the test results. Interpretation of test results included simple mechanical analysis as well as simulation by Finite Element Analysis. The first tests that were available for analysis were an irradiated 3 point bending commissioning trial and a lateral irradiated hull compression test, both simulating the loading during a 9 m lateral regulatory drop. The bending test span corresponded roughly to a fuel pin intergrid distance. The outcome of the test was a failure starting at about 35 mm lateral deflection and a few percent of total deformation. Calculations were carried out using the ANSYS code employing a shell and brick model. The hull lateral compaction test corresponds to a conservative compression by neighbouring pins at the upper end of the fuel pin. In this pin region there are no pellets inside. The cladding broke initially into two and later into four parts, all of which were rather similar. Initial calculations were carried out with LS-DYNA3D models. The models used were optimised in meshing, boundary conditions and material properties. The calculation results compared rather well with the test data, in particular for the detailed ANSYS approach of the 3 point bending test, and allowed good estimations of stresses and deformations under mechanical loading as well as the derivation of material rupture criteria. All this contributed to the development of realistic numerical analysis methods for the evaluation of LWR fuel rod behaviour under both normal and accident transport conditions. This paper describes the results of the 3 point bending

  2. SCTF Core-I test results

    International Nuclear Information System (INIS)

    Adachi, Hiromichi; Sudo, Yukio; Iwamura, Takamichi; Osakabe, Masahiro; Ohnuki, Akira; Hirano, Kemmei

    1982-07-01

    The Slab Core Test Facility (SCTF) of Japan Atomic Energy Research Institute (JAERI) was constructed to investigate two-dimensional thermohydrodynamics in the core and the communication in fluid behavior between the core and the upper plenum during the last part of blowdown, refill and reflood phases of a posturated loss-of-coolant accident (LOCA) of a pressurized water reactor (PWR). In the present report, effects of system pressure on reflooding phenomena shall be discussed based on the data of Tests S1-SH2, S1-01 and S1-02 which are the parameteris tests for system pressure effects belonging to the SCTF Core-I forced flooding test series. Major items discussed in this report are (1) hydrodynamic behavior in the system, (2) core thermal behavior, (3) core heat transfer and (4) two-dimensional hydrodynamic behavior in the pressure vessel including the core. (author)

  3. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    Science.gov (United States)

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  4. Analysis on pile testing results of post-grouting bored pile

    Science.gov (United States)

    Zheng, A. R.

    2017-04-01

    Based on static load test results, the bearing capacity of bored piles with pile-toe and pile-shaft post-grouting has been analyzed. The analysis reveals that: with post-grouting, the interface between pile and surrounding soil are strengthened and the relative sliding displacement in between is reduced; end resistance of pile is enhanced and can be mobilized at earlier stage with smaller sliding displacement. As a result, the performance of bored pile is improved with increased bearing capacity and reduced settlement.

  5. The anchors of steel wire ropes, testing methods and their results

    Directory of Open Access Journals (Sweden)

    J. Krešák

    2012-10-01

    Full Text Available The present paper introduces an application of the acoustic and thermographic method in the defectoscopic testing of immobile steel wire ropes at the most critical point, the anchor. First measurements and their results by these new defectoscopic methods are shown. In defectoscopic tests at the anchor, the widely used magnetic method gives unreliable results, and therefore presents a problem for steel wire defectoscopy. Application of the two new methods in the steel wire defectoscopy at the anchor point will enable increased safety measures at the anchor of steel wire ropes in bridge, roof, tower and aerial cable lift constructions.

  6. Effects of different centrifugation conditions on clinical chemistry and Immunology test results

    Directory of Open Access Journals (Sweden)

    Nesic Predrag

    2011-05-01

    Full Text Available Abstract Background The effect of centrifugation time of heparinized blood samples on clinical chemistry and immunology results has rarely been studied. WHO guideline proposed a 15 min centrifugation time without citing any scientific publications. The centrifugation time has a considerable impact on the turn-around-time. Methods We investigated 74 parameters in samples from 44 patients on a Roche Cobas 6000 system, to see whether there was a statistical significant difference in the test results among specimens centrifuged at 2180 g for 15 min, at 2180 g for 10 min or at 1870 g for 7 min, respectively. Two tubes with different plasma separators (both Greiner Bio-One were used for each centrifugation condition. Statistical comparisons were made by Deming fit. Results Tubes with different separators showed identical results in all parameters. Likewise, excellent correlations were found among tubes to which different centrifugation conditions were applied. Fifty percent of the slopes lay between 0.99 and 1.01. Only 3.6 percent of the statistical tests results fell outside the significance level of p Conclusion A centrifugation time of either 7 or 10 min provided identical test results compared to the time of 15 min as proposed by WHO under the conditions used in our study.

  7. Advanced Stirling Convertor Durability Testing: Plans and Interim Results

    Science.gov (United States)

    Meer, David W.; Oriti, Salvatore M.

    2012-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. In support of this program, GRC has been involved in testing Stirling convertors, including the Advanced Stirling Convertor (ASC), for use in the ASRG. This testing includes electromagnetic interference/compatibility (EMI/EMC), structural dynamics, advanced materials, organics, and unattended extended operation. The purpose of the durability tests is to experimentally demonstrate the margins in the ASC design. Due to the high value of the hardware, previous ASC tests focused on establishing baseline performance of the convertors within the nominal operating conditions. The durability tests present the first planned extension of the operating conditions into regions beyond those intended to meet the product spec, where the possibility exists of lateral contact, overstroke, or over-temperature events. These tests are not intended to cause damage that would shorten the life of the convertors, so they can transition into extended operation at the conclusion of the tests. This paper describes the four tests included in the durability test sequence: 1) start/stop cycling, 2) exposure to constant acceleration in the lateral and axial directions, 3) random vibration at increased piston amplitude to induce contact events, and 4) overstroke testing to simulate potential failures during processing or during the mission life where contact events could occur. The paper also summarizes the analysis and simulation used to predict the results of each of these tests.

  8. Test Results of the 3.9 GHz Cavity at Fermilab

    CERN Document Server

    Solyak, N

    2004-01-01

    Fermilab is developing two types of 3.9 GHz superconducting cavities to improve performances of A0 and TTF photoinjectors. In frame of this project we have built and tested two nine-cell copper models and one 3-cell niobium accelertating cavity and series of deflecting cavities. Properties of the high order modes were carefully studied in a chain of two copper cavities at room temperature. High gradient performance were tested at helium temperature. Achieved gradients and surface resistances are exceed goal parameters. In paper we discuss results of cold tests of the 3-cell accelerating and deflecting cavities.

  9. Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?

    Science.gov (United States)

    Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong; Jung, Yoon Suk

    2017-01-01

    False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; phemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; phemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24-3.40; pHemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs.

  10. Hyper-X Mach 7 Scramjet Design, Ground Test and Flight Results

    Science.gov (United States)

    Ferlemann, Shelly M.; McClinton, Charles R.; Rock, Ken E.; Voland, Randy T.

    2005-01-01

    The successful Mach 7 flight test of the Hyper-X (X-43) research vehicle has provided the major, essential demonstration of the capability of the airframe integrated scramjet engine. This flight was a crucial first step toward realizing the potential for airbreathing hypersonic propulsion for application to space launch vehicles. However, it is not sufficient to have just achieved a successful flight. The more useful knowledge gained from the flight is how well the prediction methods matched the actual test results in order to have confidence that these methods can be applied to the design of other scramjet engines and powered vehicles. The propulsion predictions for the Mach 7 flight test were calculated using the computer code, SRGULL, with input from computational fluid dynamics (CFD) and wind tunnel tests. This paper will discuss the evolution of the Mach 7 Hyper-X engine, ground wind tunnel experiments, propulsion prediction methodology, flight results and validation of design methods.

  11. Results of the Intelligence Test for Visually Impaired Children (ITVIC).

    Science.gov (United States)

    Dekker, R.; And Others

    1991-01-01

    Statistical analyses of scores on subtests of the Intelligence Test for Visually Impaired Children were done for two groups of children, either with or without usable vision. Results suggest that the battery has differential factorial and predictive validity. (Author/DB)

  12. Communication of Pulmonary Function Test Results: A Survey of Patient's Preferences.

    Directory of Open Access Journals (Sweden)

    Debbie Zagami

    Full Text Available Physician-patient communication in patients suffering from common chronic respiratory disease should encompass discussion about pulmonary function test (PFT results, diagnosis, disease education, smoking cessation and optimising inhaler technique. Previous studies have identified that patients with chronic respiratory disease/s often express dissatisfaction about physician communication. Currently there is a paucity of data regarding patient awareness of their PFT results (among those who have undergone PFTs previously or patient preferences about PFT result communication.We undertook a three-month prospective study on outpatients referred to two Pulmonary Function Laboratories. If subjects had undergone PFTs previously, the awareness of their previous test results was evaluated. All subjects were asked about their preferences for PFT result communication. Subjects were determined to have chronic respiratory disease based on their past medical history.300 subjects (50% male with a median age (± SD of 65 (± 14 years participated in the study. 99% of the study participants stated that they were at least moderately interested in knowing their PFT results. 72% (217/300 of the subjects had undergone at least one PFT in the past, 48% of whom stated they had not been made aware of their results. Fewer subjects with chronic respiratory disease preferred that only a doctor discuss their PFT results with them (28% vs. 41%, p = 0.021.Our study demonstrates that while almost all subjects want to be informed of their PFT results, this does not occur in a large number of patients. Many subjects are agreeable for their PFT results to be communicated to them by clinicians other than doctors. Further research is required to develop an efficient method of conveying PFT results that will improve patient satisfaction and health outcomes.

  13. The effect of friction on indentation test results

    International Nuclear Information System (INIS)

    Harsono, E; Swaddiwudhipong, S; Liu, Z S

    2008-01-01

    A smooth contact analysis is commonly adopted in simulated indentation. Limited studies have been performed to investigate the possibility of deviation due to this simplification. This study involves the finite element simulation of indentation by conical indenters and the Berkovich family of indenters with three different apex angles of indenter tips of 50°, 60° and 70.3°. Loading curvatures and the ratio of the remaining work done to the total work done of the load-indentation curves resulting from the simulated indentation tests considering friction and smooth contact surfaces were compared and discussed. A wide range of elasto-plastic materials obeying the power law strain hardening model were considered in this study. The results as presented herein demonstrate that the effect of friction on the two essential basic parameters from the load–indentation curves, namely, the loading curvatures and the ratio of the work done, varies depending on both mechanical properties of the target materials and the geometries of the indenter tips adopted in the investigation

  14. The Functional Task Test: Results from the One-Year Mission

    Science.gov (United States)

    Bloomberg, J. J; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Laurie, S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.; hide

    2017-01-01

    Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems including sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goal of our recently completed Functional Task Test (FTT) study was to determine the effects of spaceflight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. The FTT is comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures specifically targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and International Space Station (ISS) astronauts were tested before and after spaceflight. Additionally, we conducted a supporting study in which subjects performed the FTT protocol before and after 70 days of 6 deg head-down bed rest, an analog for spaceflight. Two groups of bed rest subjects were studied: one group who performed aerobic and resistive exercise during bed rest using protocols similar to astronauts and one group who served as non-exercise controls. The bed rest analog allowed us to isolate the impact of body unloading without other spaceflight environmental factors on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare those results with the results obtained in our spaceflight study. As an extension to the FTT study we collected data from one ISS crewmember who experienced 340 days in space using the same FTT protocol used previously to test spaceflight and bed rest subjects. Data were collected three times preflight and 1.7, 7.5 and 36.5 days after

  15. Power-cooling mismatch test series. Test PCM-2A; test results report

    International Nuclear Information System (INIS)

    Cawood, G.W.; Holman, G.W.; Martinson, Z.R.; Legrand, B.L.

    1976-09-01

    The report describes the results of an in-pile experimental investigation of pre- and postcritical heat flux (CHF) behavior of a single 36-inch-long, pressurized water reactor (PWR) type, UO 2 -fueled, zircaloy-clad fuel rod. The nominal coolant conditions for pressure and temperature were representative of those found in a commercial PWR. Nine separate departures from nucleate boiling (DNB) cycles were performed by either of two different methods: (a) decreasing the coolant flow rate while the fuel rod power was held constant, or (b) increasing the fuel rod power while the coolant flow rate was held constant. DNB was obtained during eight of the nine cycles performed. For the final flow reduction, the mass flux was decreased to 6.1 x 10 5 lb/hr-ft 2 at a constant peak linear heat generation rate of 17.8 kW/ft. The fuel rod was allowed to remain in film boiling for about 210 seconds during this final flow reduction. The fuel rod remained intact during the test. Results of on-line measurements of the fuel rod behavior are presented together with discussion of instrument performance. A comparison of the data with Fuel Rod Analysis Program-Transient 2 (FRAP-T2) computer code calculations is included

  16. Test results and operational characteristics of prototype SSCL half cell

    International Nuclear Information System (INIS)

    McInturff, A.D.; Burgett, W.; Carter, H.

    1994-01-01

    The SSCL Accelerator System's String Test (ASST) has had several cool down, subsequent operational test series, and warm up cycles. The first cycle of these was rather limited in scope as mandated by Congress. The subsequent tests have been performed to obtain more complete information about parameters of, or operating experience with, the ensemble of magnets and spools when operating serially as in accelerator operations. The tests and procedures performed to date have emphasized cryogenic, mechanical, and electrical operations. These have included running, as well as upset conditions, i.e., superconducting to normal transition of the string (quench). This paper represents a summary of the operational test results and characteristics seen to date. A limited discussion will be included as to their implications with respect to a successful accelerator operation

  17. Results of patch testing with lavender oil in Japan.

    Science.gov (United States)

    Sugiura, M; Hayakawa, R; Kato, Y; Sugiura, K; Hashimoto, R

    2000-09-01

    We report the annual results of patch testing with lavender oil for a 9-year period from 1990 to 1998 in Japan. Using Finn Chambers and Scanpor tape, we performed 2-day closed patch testing with lavender oil 20% pet. on the upper back of each patient suspected of having cosmetic contact dermatitis. We compared the frequency of positive patch tests to lavender oil each year with those to other fragrances. We diagnosed contact allergy when patch test reactions were + or Japan, there has been a trend for aromatherapy using lavender oil. With this trend, placing dried lavender flowers in pillows, drawers, cabinets, or rooms has become a new fashion. We asked patients who showed a positive reaction to lavender oil about their use of dried lavender flowers. We confirmed the use of dried lavender flowers in 5 cases out of 11 positive cases in 1997 and 8 out of 15 positive cases in 1998. We concluded that the increase in patch test positivity rates to lavender oil in 1997 and 1998 was due to the above fashion, rather than due to fragrances in cosmetic products.

  18. Results of initial nuclear tests on LWBR (LWBR Development Program)

    International Nuclear Information System (INIS)

    Sarber, W.K.

    1979-06-01

    This report presents and discusses the results of physics tests performed at beginning of life on the Light Water Breeder Reactor (LWBR). These tests have confirmed that movable seed assembly critical positions and reactivity worths, temperature coefficients, xenon transient characteristics, core symmetry, and core shutdown are within the range of values used in the design of the LWBR and its reactor protection analysis. Measured core physics parameters were found to be in good agreement with the calculated values

  19. Acoustic results of the Boeing model 360 whirl tower test

    Science.gov (United States)

    Watts, Michael E.; Jordan, David

    1990-09-01

    An evaluation is presented for whirl tower test results of the Model 360 helicopter's advanced, high-performance four-bladed composite rotor system intended to facilitate over-200-knot flight. During these performance measurements, acoustic data were acquired by seven microphones. A comparison of whirl-tower tests with theory indicate that theoretical prediction accuracies vary with both microphone position and the inclusion of ground reflection. Prediction errors varied from 0 to 40 percent of the measured signal-to-peak amplitude.

  20. Experimental results from containment piping bellows subjected to severe accident conditions: Results from bellows tested in corroded conditions. Volume 2

    International Nuclear Information System (INIS)

    Lambert, L.D.; Parks, M.B.

    1995-10-01

    Bellows are an integral part of the containment pressure boundary in nuclear power plants. They are used at piping penetrations to allow relative movement between piping and the containment wall, while minimizing the load imposed on the piping and wall. Piping bellows are primarily used in steel containments; however, they have received limited use in some concrete (reinforced and prestressed) containments. In a severe accident they may be subjected to pressure and temperature conditions that exceed the design values, along with a combination of axial and lateral deflections. A test program to determine the leak-tight capacity of containment penetration bellows is being conducted at Sandia National Laboratories under the sponsorship of the US Nuclear Regulatory Commission. Several different bellows geometries, representative of actual containment bellows, have been subjected to extreme deflections along with pressure and temperature loads. The bellows geometries and loading conditions are described along with the testing apparatus and procedures. A total of nineteen bellows have been tested. Thirteen bellows were tested in ''like-new'' condition (results reported in Volume 1), and six were tested in a corroded condition. The tests showed that bellows in ''like-new'' condition are capable of withstanding relatively large deformations, up to, or near, the point of full compression or elongation, before developing leakage, while those in a corroded condition did not perform as well, depending on the amount of corrosion. The corroded bellows test program and results are presented in this report

  1. Driving simulator test results Deliverable no D6.3. Final draft

    NARCIS (Netherlands)

    Weiland, J.; Mattes, S.; Kuhn, F.; Gelau, Ch.; Schindhelm, R.; Hoedemaeker, D.D.M.

    2003-01-01

    Deliverable 6.3 reports the procedure and results from a driving simulator study. This study was carried out to test the efficiency of the principles of the in-vehicle information manager, which was developed within the Comunicar project. Thirty-six subjects were tested in a fixed-base driving

  2. Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Maddalena, Randy L [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-01

    The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The other home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.

  3. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m 2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  4. Test Results and Comparison of Triaxial Strength Testing of Waste Isolation Pilot Plant Clean Salt

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Stuart A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined, the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.

  5. SP-100 Fuel Pin Performance: Results from Irradiation Testing

    Science.gov (United States)

    Makenas, Bruce J.; Paxton, Dean M.; Vaidyanathan, Swaminathan; Marietta, Martin; Hoth, Carl W.

    1994-07-01

    A total of 86 experimental fuel pins with various fuel, liner, and cladding candidate materials have been irradiated in the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF) reactor as part of the SP-100 fuel pin irradiation testing program. Postirradiation examination results from these fuel pins are key in establishing performance correlations and demonstrating the lifetime and safety of the reactor fuel system. This paper provides a brief description of the in-reactor fuel pin tests and presents the most recent irradiation data on the performance of wrought rhenium (Re) liner material and high density UN fuel at goal burnup of 6 atom percent (at. %). It also provides an overview of the significant variety of other fuel/liner/cladding combinations which were irradiated as part of this program and which may be of interest to more advanced efforts.

  6. Should Australia Ban the Use of Genetic Test Results in Life Insurance?

    OpenAIRE

    Tiller, Jane; Otlowski, Margaret; Lacaze, Paul

    2017-01-01

    Under current Australian regulation, life insurance companies can require applicants to disclose all genetic test results, including results from research or direct-to-consumer tests. Life insurers can then use this genetic information in underwriting and policy decisions for mutually rated products, including life, permanent disability, and total income protection insurance. Over the past decade, many countries have implemented moratoria or legislative bans on the use of genetic information ...

  7. Summary of Test Results for Daya Bay Rock Samples

    International Nuclear Information System (INIS)

    Onishi, Celia Tiemi; Dobson, Patrick; Nakagawa, Seiji

    2004-01-01

    A series of analytical tests was conducted on a suite of granitic rock samples from the Daya Bay region of southeast China. The objective of these analyses was to determine key rock properties that would affect the suitability of this location for the siting of a neutrino oscillation experiment. This report contains the results of chemical analyses, rock property measurements, and a calculation of the mean atomic weight

  8. Setup, tests and results for the ATLAS TileCal Read Out Driver production

    CERN Document Server

    Valero, Alberto; Castillo, V; Cuenca, C; Ferrer, A; Fullana, E; González, V; Higón, E; Munar, A; Poveda, J; Ruiz-Martínez, A; Salvachúa, B; Sanchís, E; Solans, C; Soret, J; Torres, J; Valls, J A

    2007-01-01

    In this paper we describe the performance and test results of the production of the 38 ATLAS TileCal Read Out Drivers (RODs). We first describe the basic hardware specifications and firmware functionality of the modules, the test-bench setup used for production and the test procedure to qualify the boards. We then finally show and discuss the performance results.

  9. Comparison of theoretical and test results on shear wall seismic response

    International Nuclear Information System (INIS)

    Gantenbein, F.; Wang, F.; Dalbera, J.

    1991-01-01

    As reinforced concrete shear walls are important resisting components of buildings in nuclear power facilities, it is important to study their ultimate behavior under dynamic loading. An experimental and analytical work has been undertaken on shear walls with and without openings, in order to develop and validate their model. This paper is related to the walls without openings. While pretest calculations have already been reported (Wang and al. 1989) and the test results are given in Gantenbein and al. 1991, this paper is mainly related to the comparison of test and calculation results on the wall initial stiffness and the time history of the wall motion

  10. Electronic Detection of Delayed Test Result Follow-Up in Patients with Hypothyroidism.

    Science.gov (United States)

    Meyer, Ashley N D; Murphy, Daniel R; Al-Mutairi, Aymer; Sittig, Dean F; Wei, Li; Russo, Elise; Singh, Hardeep

    2017-07-01

    Delays in following up abnormal test results are a common problem in outpatient settings. Surveillance systems that use trigger tools to identify delayed follow-up can help reduce missed opportunities in care. To develop and test an electronic health record (EHR)-based trigger algorithm to identify instances of delayed follow-up of abnormal thyroid-stimulating hormone (TSH) results in patients being treated for hypothyroidism. We developed an algorithm using structured EHR data to identify patients with hypothyroidism who had delayed follow-up (>60 days) after an abnormal TSH. We then retrospectively applied the algorithm to a large EHR data warehouse within the Department of Veterans Affairs (VA), on patient records from two large VA networks for the period from January 1, 2011, to December 31, 2011. Identified records were reviewed to confirm the presence of delays in follow-up. During the study period, 645,555 patients were seen in the outpatient setting within the two networks. Of 293,554 patients with at least one TSH test result, the trigger identified 1250 patients on treatment for hypothyroidism with elevated TSH. Of these patients, 271 were flagged as potentially having delayed follow-up of their test result. Chart reviews confirmed delays in 163 of the 271 flagged patients (PPV = 60.1%). An automated trigger algorithm applied to records in a large EHR data warehouse identified patients with hypothyroidism with potential delays in thyroid function test results follow-up. Future prospective application of the TSH trigger algorithm can be used by clinical teams as a surveillance and quality improvement technique to monitor and improve follow-up.

  11. Identification of Anisotropic Criteria for Stratified Soil Based on Triaxial Tests Results

    Science.gov (United States)

    Tankiewicz, Matylda; Kawa, Marek

    2017-09-01

    The paper presents the identification methodology of anisotropic criteria based on triaxial test results. The considered material is varved clay - a sedimentary soil occurring in central Poland which is characterized by the so-called "layered microstructure". The strength examination outcomes were identified by standard triaxial tests. The results include the estimated peak strength obtained for a wide range of orientations and confining pressures. Two models were chosen as potentially adequate for the description of the tested material, namely Pariseau and its conjunction with the Jaeger weakness plane. Material constants were obtained by fitting the model to the experimental results. The identification procedure is based on the least squares method. The optimal values of parameters are searched for between specified bounds by sequentially decreasing the distance between points and reducing the length of the searched range. For both considered models the optimal parameters have been obtained. The comparison of theoretical and experimental results as well as the assessment of the suitability of selected criteria for the specified range of confining pressures are presented.

  12. Test results of the UNK superconducting dipole magnets

    International Nuclear Information System (INIS)

    Ageev, A.I.; Andreev, N.I.; Gridasov, V.I.

    1993-01-01

    Results of studied, training, temperature and velocity dependence of 25 critical current of superconducting magnets (SC), as well as, of dynamic losses of dipole and statical inflows in UNK operating cycle at currents that are higher than critical ones (5250 A), are presented. Service life tests of SC-dipole demonstrated that their design may ensure durable operation of magnets under UNK conditions. Conclusions are made that temperature margin of magnets equal to 0.8 K will enable to ensure their reliable operation under dynamic and radiation heat releases at acceleration and extraction of beam, as well as, under emergency extraction of stored energy. 4 refs.; 5 figs

  13. Is the psychological impact of genetic testing moderated by support and sharing of test results to family and friends?

    Science.gov (United States)

    Lapointe, Julie; Dorval, Michel; Noguès, Catherine; Fabre, Roxane; Julian-Reynier, Claire

    2013-12-01

    Receiving the results of genetic tests for a breast and ovarian cancer susceptibility can be a stressful experience. Here we studied the effects of social support (SS) and the sharing of test results on the psychological impact of BRCA1/2 test result disclosure. We also compared carriers and non-carriers on sharing, SS and psychological impact. Five-hundred and twenty-two unaffected women were followed prospectively for 2 years after receiving their test results. Psychological impact was measured on the impact of event scale. Multivariate multi-level models were used, and all the analyses were stratified depending on mutation status (carriers vs non-carriers). Two weeks after receiving their BRCA1/2 results, carriers had shared their test results less frequently than non-carriers (p test results was not significantly associated with psychological impact. Availability of SS was significantly associated with better psychological adjustment across time among carriers (p importance of SS should be stressed, and possible ways of enlisting people in their entourage for this purpose should be discussed in the context of clinical encounters.

  14. CRBRP design and test results for fuel handling systems, plugs, and seals

    International Nuclear Information System (INIS)

    Berg, G.E.

    1977-01-01

    The fuel handling system and reactor rotating plugs for the Clinch River Breeder Reactor Plant (CRBRP) are based primarily on existing technology and, in many respects, follow the concept developed for the Fast Flux Test Facility (FFTF). The equipment and the development programs initiated to verify its performance are described. Test results obtained from the development program, and the extent to which these results verified original design selections, or suggested potential improvements, are discussed

  15. Results of the 1000 Hour Rotary Microfilter Endurance Test

    International Nuclear Information System (INIS)

    Herman, D.

    2010-01-01

    During operation, a primary concern is lifetime of the mechanical seal. Leakage from main shaft mechanical seal is expected to be first indication of wear on rotary filter but will not be the ultimate failure of the filter. Initial clearance inadequate to support thermal expansion resulted in initial scarring of journal. Tolerances adjusted and no journal issues were found during 1000 hour test. Disassembly and inspection of the rotary joint seals showed no unusual wear. No leakage observed during test. Total operation time over 1500 hours. Test summary successfully demonstrated: (1) Filtration of a 'challenging' SRS simulant up to 15 wt % insoluble solids in a 5.6 M salt simulant; (2) Sludge washing; (3) In-situ acid cleaning with dilute acid; (4) Over 1000 hours of operation on new journal material; and (5) Over 1500 hours of operation on all seals. The filter out lasted: 2 air compressors, 2 power outages (one planned), 2 chillers, 1 fire, 1 electrical breaker and 1 feed pump seal.

  16. 40 CFR 205.57-5 - Reporting of the test results.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Reporting of the test results. 205.57-5 Section 205.57-5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.57-5...

  17. Do sediment type and test durations affect results of laboratory-based, accelerated testing studies of permeable pavement clogging?

    Science.gov (United States)

    Nichols, Peter W B; White, Richard; Lucke, Terry

    2015-04-01

    Previous studies have attempted to quantify the clogging processes of Permeable Interlocking Concrete Pavers (PICPs) using accelerated testing methods. However, the results have been variable. This study investigated the effects that three different sediment types (natural and silica), and different simulated rainfall intensities, and testing durations had on the observed clogging processes (and measured surface infiltration rates) of laboratory-based, accelerated PICP testing studies. Results showed that accelerated simulated laboratory testing results are highly dependent on the type, and size of sediment used in the experiments. For example, when using real stormwater sediment up to 1.18 mm in size, the results showed that neither testing duration, nor stormwater application rate had any significant effect on PICP clogging. However, the study clearly showed that shorter testing durations generally increased clogging and reduced the surface infiltration rates of the models when artificial silica sediment was used. Longer testing durations also generally increased clogging of the models when using fine sediment (<300 μm). Results from this study will help researchers and designers better anticipate when and why PICPs are susceptible to clogging, reduce maintenance and extend the useful life of these increasingly common stormwater best management practices. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Ground vibration test results of a JetStar airplane using impulsive sine excitation

    Science.gov (United States)

    Kehoe, Michael W.; Voracek, David F.

    1989-01-01

    Structural excitation is important for both ground vibration and flight flutter testing. The structural responses caused by this excitation are analyzed to determine frequency, damping, and mode shape information. Many excitation waveforms have been used throughout the years. The use of impulsive sine (sin omega t)/omega t as an excitation waveform for ground vibration testing and the advantages of using this waveform for flight flutter testing are discussed. The ground vibration test results of a modified JetStar airplane using impulsive sine as an excitation waveform are compared with the test results of the same airplane using multiple-input random excitation. The results indicated that the structure was sufficiently excited using the impulsive sine waveform. Comparisons of input force spectrums, mode shape plots, and frequency and damping values for the two methods of excitation are presented.

  19. Results of a first beam test of hadron blind trackers

    Energy Technology Data Exchange (ETDEWEB)

    Chen, M. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Luckey, D. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Smolin, M. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Sumorok, K. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Zhang, X. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Bolozdynya, A. (ITEP, Moscow (Russian Federation)); Belogurov, S. (ITEP, Moscow (Russian Federation)); Churakov, D. (ITEP, Moscow (Russian Federation)); Koutchenkov, A. (ITEP, Moscow (Russian Federation)); Kovalenko, A. (ITEP, Moscow (Russian Federation)); Kuzichev, V. (ITEP, Moscow (Russian Federation)); Lebedenko, V. (ITEP, Moscow (Russian Federation)); Sheinkman, V. (ITEP, Moscow (Russian Federation)); Smirnov, G. (ITEP, Moscow (Russian Federation)); Safronov, G. (ITEP, Moscow (Russian Federation)); Vinogradov, V. (ITEP, Moscow (Russian Federation)); Giomataris, Y. (IPN,

    1994-07-15

    We describe the experimental results of a new type of electron tracker, called Hadron Blind Detector or HBD. An HBD prototype was tested with gas mixtures of CF[sub 4] with He or Ne and a parallel plate avalanche chamber having a CsI photocathode of eight pads. Beam tests confirm the large Cherenkov light bandwidth in the EUV region that can be obtained with such gas mixtures. It results in a large quality factor of about 500 cm[sup -1] which allows HBD operation with a much shorter radiator thickness than conventional Cherenkov counters. Full electron efficiency was obtained, while pions were rejected up to momenta of 9 GeV/c. HBD is unique in measuring electron trajectories near the vertex, vetoing Dalitz pairs, and providing trigger on electrons among heavy hadron background. We discuss the use of such detectors for lepton identification and detection in high energy physics experiments and especially in heavy ion colliders. ((orig.))

  20. Results of a first beam test of hadron blind trackers

    International Nuclear Information System (INIS)

    Chen, M.; Luckey, D.; Smolin, M.; Sumorok, K.; Zhang, X.; Bolozdynya, A.; Belogurov, S.; Churakov, D.; Koutchenkov, A.; Kovalenko, A.; Kuzichev, V.; Lebedenko, V.; Sheinkman, V.; Smirnov, G.; Safronov, G.; Vinogradov, V.; Giomataris, Y.; Joseph, C.; Werlen, M.; Charpak, G.; Blumenfeld, B.; Gougas, A.K.; Steele, D.; Akopyan, M.

    1994-01-01

    We describe the experimental results of a new type of electron tracker, called Hadron Blind Detector or HBD. An HBD prototype was tested with gas mixtures of CF 4 with He or Ne and a parallel plate avalanche chamber having a CsI photocathode of eight pads. Beam tests confirm the large Cherenkov light bandwidth in the EUV region that can be obtained with such gas mixtures. It results in a large quality factor of about 500 cm -1 which allows HBD operation with a much shorter radiator thickness than conventional Cherenkov counters. Full electron efficiency was obtained, while pions were rejected up to momenta of 9 GeV/c. HBD is unique in measuring electron trajectories near the vertex, vetoing Dalitz pairs, and providing trigger on electrons among heavy hadron background. We discuss the use of such detectors for lepton identification and detection in high energy physics experiments and especially in heavy ion colliders. ((orig.))

  1. VLT deformable secondary mirror: integration and electromechanical tests results

    Science.gov (United States)

    Biasi, R.; Andrighettoni, M.; Angerer, G.; Mair, C.; Pescoller, D.; Lazzarini, P.; Anaclerio, E.; Mantegazza, M.; Gallieni, D.; Vernet, E.; Arsenault, R.; Madec, P.-Y.; Duhoux, P.; Riccardi, A.; Xompero, M.; Briguglio, R.; Manetti, M.; Morandini, M.

    2012-07-01

    The VLT Deformable secondary is planned to be installed on the VLT UT#4 as part of the telescope conversion into the Adaptive Optics test Facility (AOF). The adaptive unit is based on the well proven contactless, voice coil motor technology that has been already successfully implemented in the MMT, LBT and Magellan adaptive secondaries, and is considered a promising technical choice for the forthcoming ELT-generation adaptive correctors, like the E-ELT M4 and the GMT ASM. The VLT adaptive unit has been recently assembled after the completion of the manufacturing and modular test phases. In this paper, we present the most relevant aspects of the system integration and report the preliminary results of the electromechanical tests performed on the unit. This test campaign is a typical major step foreseen in all similar systems built so far: thanks to the metrology embedded in the system, that allows generating time-dependent stimuli and recording in real time the position of the controlled mirror on all actuators, typical dynamic response quality parameters like modal settling time, overshoot and following error can be acquired without employing optical measurements. In this way the system dynamic and some aspect of its thermal and long term stability can be fully characterized before starting the optical tests and calibrations.

  2. LWR aerosol containment experiments (LACE) program and initial test results

    International Nuclear Information System (INIS)

    Muhlestein, L.D.; Hilliard, R.K.; Bloom, G.R.; McCormack, J.D.; Rahn, F.J.

    1985-01-01

    The LWR aerosol containment experiments (LACE) program is described. The LACE program is being performed at the Hanford Engineer Development Laboratory (operated by Westinghouse Hanford Company) and the initial tests are sponsored by EPRI. The objectives of the LACE program are: to demonstrate, at large-scale, inherent radioactive aerosol retention behavior for postulated high consequence LWR accident situations; and to provide a data base to be used for aerosol behavior . Test results from the first phase of the LACE program are presented and discussed. Three large-scale scoping tests, simulating a containment bypass accident sequence, demonstrated the extent of agglomeration and deposition of aerosols occurring in the pipe pathway and vented auxiliary building under realistic accident conditions. Parameters varied during the scoping tests were aerosol type and steam condensation

  3. Quality control of achieved results of testings in interlaboratory reference measurements

    International Nuclear Information System (INIS)

    Rosskopfova, O.; Matel, L.; Rajec, P.

    2009-01-01

    The laboratory accredited according to the ISO/IEC 17025:2005 must ensure the quality of reported results including corresponding uncertainty. The important point of view of correct evaluation of results is precision and uncertainty. The validation of a method is an experimental verification and an objective proof that the method is suitable for planned application. The most frequent way of validation is a participation in an intercomparison test. LARCHA laboratory regularly participates in the proficiency tests on the determination of gamma, beta and alpha emitting radionuclides in various matrices. It is also a proof for the laboratory and client that the methods for radionuclides determination are validated according to the rules of ISO/IEC 17025:2005. (authors)

  4. Results of gap conductance tests in the power burst facility

    International Nuclear Information System (INIS)

    Garner, R.W.; Sparks, D.T.

    1977-01-01

    Light water reactor (LWR) fuel rod behavior studies are being conducted by the Thermal Fuels Behavior Program of EG and G Idaho, Inc. These studies are being performed under contract to the Energy Research and Development Adminstration at the Idaho National Engineering Laboratory (INEL), as part of the Nuclear Regulatory Commission's Water Reactor Safety Research Fuel Behavior Program. Experimental data for verification of analytical models developed to predict light water nuclear fuel rod behavior under normal and postulated accident conditions are being obtained from a variety of in-reactor and out-of-reactor experiments. This paper summarizes the results of tests performed in the Power Burst Facility (PBF) to obtain data from which the thermal response, gap conductance, and stored energy of LWR fuel rods can be determined. Primary objectives of the PBF gap conductance test program are (a) to obtain data on a variety of pressurized water reactor (PWR) and boiling water reactor (BWR) fuel rod designs, under a wide range of operating conditions, from which gap conductance values can be determined and (b) to evaluate experimentally the power oscillation method for measuring the gap conductance and thermal response of a fresh or burned LWR fuel rod. Tests have been performed with both irradiated and unirradiated PWR-type fuel and with fresh BWR-type fuel rods. Some PWR rod test results are described, and the thermal response data from BWR rod tests are discussed in greater detail. Comparisons are made of gap conductance values determined by the tests with analytically calculated values using the Fuel Rod Analysis Program-Transient (FRAP-T) computer code. These comparisons provide insight into both the experimental measurements methods and the validity of the gap conductance models

  5. Pattern Of Skin Prick Allergy Test Results In Enugu | Mgbor ...

    African Journals Online (AJOL)

    In this study we report on pattern of allergy prick skin test results found among atopic patients attending the department of otorhinolargngology of the University of Nigeria Teaching Hospital Enugu and Hansa Clinics, Enugu and propose ways of minimizing the exposure of the population to allergens. Material and method

  6. Measurement of ability emotional intelligence: results for two new tests.

    Science.gov (United States)

    Austin, Elizabeth J

    2010-08-01

    Emotional intelligence (EI) has attracted considerable interest amongst both individual differences researchers and those in other areas of psychology who are interested in how EI relates to criteria such as well-being and career success. Both trait (self-report) and ability EI measures have been developed; the focus of this paper is on ability EI. The associations of two new ability EI tests with psychometric intelligence, emotion perception, and the Mayer-Salovey-Caruso EI test (MSCEIT) were examined. The new EI tests were the Situational Test of Emotion Management (STEM) and the Situational Test of Emotional Understanding (STEU). Only the STEU and the MSCEIT Understanding Emotions branch were significantly correlated with psychometric intelligence, suggesting that only understanding emotions can be regarded as a candidate new intelligence component. These understanding emotions tests were also positively correlated with emotion perception tests, and STEM and STEU scores were positively correlated with MSCEIT total score and most branch scores. Neither the STEM nor the STEU were significantly correlated with trait EI tests, confirming the distinctness of trait and ability EI. Taking the present results as a starting-point, approaches to the development of new ability EI tests and models of EI are suggested.

  7. Initial CGE Model Results Summary Exogenous and Endogenous Variables Tests

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Brian Keith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Boero, Riccardo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rivera, Michael Kelly [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-07

    The following discussion presents initial results of tests of the most recent version of the National Infrastructure Simulation and Analysis Center Dynamic Computable General Equilibrium (CGE) model developed by Los Alamos National Laboratory (LANL). The intent of this is to test and assess the model’s behavioral properties. The test evaluated whether the predicted impacts are reasonable from a qualitative perspective. This issue is whether the predicted change, be it an increase or decrease in other model variables, is consistent with prior economic intuition and expectations about the predicted change. One of the purposes of this effort is to determine whether model changes are needed in order to improve its behavior qualitatively and quantitatively.

  8. Test results of the Los Alamos ferrite-tuned rf cavity

    International Nuclear Information System (INIS)

    Friedrichs, C.C.; Spalek, G.; Carlini, R.D.; Smythe, W.R.

    1987-03-01

    An rf accelerating cavity appropriate for use in a 20% frequency bandwidth synchrotron has been designed, fabricated, and is now being tested at Los Alamos. The cavity-amplifier system was designed to produce a peak rf gap voltage of 90 kV over the range from 50 to 60 MHz. Special features of the system are the transversely biased ferrite tuner, capacitive coupling of the amplifier to the cavity, and a 15-cm beam pipe. High-power rf testing of the cavity-amplifier system started in August 1986, using an adjustable dc power supply to bias the ferrite. This paper describes the cavity-amplifier circuit and the test results to the present time. Future plans are also discussed

  9. North Korea nuclear test analysis results using KMA seismic and infrasound networks

    Science.gov (United States)

    Jeon, Y. S.; Park, E.; Lee, D.; Min, K.; CHO, S.

    2017-12-01

    Democratic People's Republic of Korea(DPRK) carried out 6th nuclear test on 3 Sep. 2017 at 03:30 UTC. Seismic and infrasound network operated by Korea Meteorological Administration(KMA) successfully detected signals took place in the DPRK's test site, Punggye-ri. First, we checked that Pg/Lg spectral amplitude ratio greater than 1 in the frequency range from 1.0 to 10.0 Hz is useful to discriminate between DPRK test signals and natural earthquakes. KMA's infrasound stations of Cheorwon(CW) and Yanggu(YG) successfully monitored the azimuth direction of the arrival of the infrasound signals generated from DPRK underground nuclear explosions, including the recent test on September 03, 2017. The azimuthal direction of 210(CW) and 130 (YG) point out Punggye-ri test site. Complete waveforms at stations MDJ, CHC2, YNCB in long period(0.05 to 0.1 HZ) are jointly inverted with local P-wave polarities to generate moment tensor inversion result of the explosive moment 1.20e+24 dyne cm(Mw 5.31) and 65% of ISO. The moment magnitude of 5th, 4th and 3rd are 4.61, 4.69 and 4.46 respectively. Source type moment tensor inversion result of DPRK nuclear tests show that the event is significantly away from the deviatoric line of the Hudson et at. (1989) source-type diagram and identifies as having a significant explosive component. Analysis results using seismic and infrasound network verify that the DPRK's explosion tests classified as nuclear test.

  10. Waiting is the hardest part: anticipating medical test results affects processing and recall of important information.

    Science.gov (United States)

    Portnoy, David B

    2010-07-01

    Waiting for medical test results that signal physical harm can be a stressful and potentially psychologically harmful experience. Despite this, interventionists and physicians often use this wait time to deliver behavior change messages and other important information about the test, possible results and its implications. This study examined how "bracing" for a medical test result impacts cognitive processing, as well as recall of information delivered during this period. Healthy U.S. university students (N = 150) were tested for a deficiency of a fictitious saliva biomarker that was said to be predictive of long-term health problems using a 2 (Test Result) x 2 (Expected immediacy of result: 10 min, 1 month) factorial design. Participants expecting to get the test result shortly should have been bracing for the result. While waiting for the test results participants completed measures of cognitive processing. After participants received the test result, recall of information about the biomarker was tested in addition to cognitive measures. One week later, participants who were originally told they did not have the deficiency had their recall assessed again. Results showed that anticipating an imminent test result increased cognitive distraction in the processing of information and lowered recall of information about the test and the biomarker. These results suggest that delivering critical information to patients after administering a test and immediately before giving the results may not be optimal.

  11. Correlation of analysis with high level vibration test results for primary coolant piping

    International Nuclear Information System (INIS)

    Park, Y.J.; Hofmayer, C.H.; Costello, J.F.

    1992-01-01

    Dynamic tests on a modified 1/2.5-scale model of pressurized water reactor (PWR) primary coolant piping were performed using a large shaking table at Tadotsu, Japan. The High Level Vibration Test (HLVT) program was part of a cooperative study between the United States (Nuclear Regulatory Commission/Brookhaven National Laboratory, NRC/BNL) and Japan (Ministry of International Trade and Industry/Nuclear Power Engineering Center). During the test program, the excitation level of each test run was gradually increased up to the limit of the shaking table and significant plastic strains, as well as cracking, were induced in the piping. To fully utilize the test results, NRC/BNL sponsored a project to develop corresponding analytical predictions for the nonlinear dynamic response of the piping for selected test runs. The analyses were performed using both simplified and detailed approaches. The simplified approaches utilize a linear solution and an approximate formulation for nonlinear dynamic effects such as the use of a deamplification factor. The detailed analyses were performed using available nonlinear finite element computer codes, including the MARC, ABAQUS, ADINA and WECAN codes. A comparison of various analysis techniques with the test results shows a higher prediction error in the detailed strain values in the overall response values. A summary of the correlation analyses was presented before the BNL. This paper presents a detailed description of the various analysis results and additional comparisons with test results

  12. Tuberculosis Infection in Urban Adolescents: Results of a School-Based Testing Program.

    Science.gov (United States)

    Barry, M. Anita; And Others

    1990-01-01

    Discusses a tuberculosis skin testing program introduced for seventh and tenth grade students in Boston (Massachusetts) public schools. Positivity rate was significantly higher in tenth grade students. Among those testing positive, the majority were born outside the United States. Results suggest that testing may identify a significant number of…

  13. Patch test results with patients' own perfumes, deodorants and shaving lotions: results of the IVDK 1998-2002.

    Science.gov (United States)

    Uter, W; Geier, J; Schnuch, A; Frosch, P J

    2007-03-01

    Assessment of the value of patch testing patients' own perfumes, eau de toilette, deodorants and shaving lotions with regard to diagnosing contact allergy to fragrances, and an analysis of the spectrum of concurrent patch test reactions to single fragrance allergens. Data of the Information Network of Departments of Dermatology (IVDK; http://www.ivdk.org) regarding patch test results with above products brought in by the patient, considered as possible cause of contact dermatitis, were retrospectively analysed. Between 1998 and 2002, 1468 patients were patch tested with 2557 single products (deodorants, n = 1094; eau de toilette, n = 598; perfume, n = 530; and pre- or after-shave, n = 325; remainder not classifiable), mostly 'as is'. Positive reactions were observed in 129 patients (to 191 products). In 58 of these patients, no further patch test reactions to the fragrance mix (FM-I), Myroxylon pereirae resin (balsam of Peru) or 4-(4-hydroxy-4-methyl-pentyl)-3-cyclohexencarboxaldehyde (e.g. Lyral(R)) were found. A strong association between contact sensitivity to the above commercial allergens and positive reactions to products was observed. Some single compounds such as ylang-ylang oil, propolis and especially oak moss absolute are important allergens in the 'perfume-positive' subgroup, but less in a subgroup positive to own deodorants. Patch testing this scope of products, brought in by the patient, can be regarded as a simple, safe and effective method to diagnose clinically relevant contact sensitization - the more so, as the composition of such products is ever-changing, and the sensitivity of established 'screening allergens' is thus insufficient.

  14. [Do we always correctly interpret the results of statistical nonparametric tests].

    Science.gov (United States)

    Moczko, Jerzy A

    2014-01-01

    Mann-Whitney, Wilcoxon, Kruskal-Wallis and Friedman tests create a group of commonly used tests to analyze the results of clinical and laboratory data. These tests are considered to be extremely flexible and their asymptotic relative efficiency exceeds 95 percent. Compared with the corresponding parametric tests they do not require checking the fulfillment of the conditions such as the normality of data distribution, homogeneity of variance, the lack of correlation means and standard deviations, etc. They can be used both in the interval and or-dinal scales. The article presents an example Mann-Whitney test, that does not in any case the choice of these four nonparametric tests treated as a kind of gold standard leads to correct inference.

  15. LOGICAL CONDITIONS ANALYSIS METHOD FOR DIAGNOSTIC TEST RESULTS DECODING APPLIED TO COMPETENCE ELEMENTS PROFICIENCY

    Directory of Open Access Journals (Sweden)

    V. I. Freyman

    2015-11-01

    Full Text Available Subject of Research.Representation features of education results for competence-based educational programs are analyzed. Solution importance of decoding and proficiency estimation for elements and components of discipline parts of competences is shown. The purpose and objectives of research are formulated. Methods. The paper deals with methods of mathematical logic, Boolean algebra, and parametrical analysis of complex diagnostic test results, that controls proficiency of some discipline competence elements. Results. The method of logical conditions analysis is created. It will give the possibility to formulate logical conditions for proficiency determination of each discipline competence element, controlled by complex diagnostic test. Normalized test result is divided into noncrossing zones; a logical condition about controlled elements proficiency is formulated for each of them. Summarized characteristics for test result zones are imposed. An example of logical conditions forming for diagnostic test with preset features is provided. Practical Relevance. The proposed method of logical conditions analysis is applied in the decoding algorithm of proficiency test diagnosis for discipline competence elements. It will give the possibility to automate the search procedure for elements with insufficient proficiency, and is also usable for estimation of education results of a discipline or a component of competence-based educational program.

  16. Overview of results from 2D airfoil testing at Risoe

    Energy Technology Data Exchange (ETDEWEB)

    Fuglsang, P. [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1997-12-31

    This paper gives an overview of the results from two dimensional airfoil testing at Risoe. A two dimensional testing method was recently developed where a test rig is inserted into an open jet flow in a wind tunnel of the close return loop type with an open test section. Pressure measurements provide the lift and drag forces. Both stationary flow and dynamic inflow from pitch motion are possible. The wind tunnel static pressure and total dynamic pressures were calibrated and wind tunnel boundary corrections were found. So far, the testing method was verified by comparison of NACA 63-215 airfoil measurements to numerical predictions and to measurements. Furthermore, the Risoe-1, FFA-W3-241, FFA-W3-301 and NACA 63-430 airfoils were measured. Different types of leading edge roughness and vortex generators were investigated. For all airfoils, good agreements with predictions were obtained on both pressure distribution and on lift coefficient. The drag coefficients were slightly higher than predicted. (eg) 10 refs.

  17. Depressurisation studies. Phase 2: results of Tests 127 and 128

    International Nuclear Information System (INIS)

    Edwards, A.R.; Borgartz, B.O.; Goodman, R.M.E.; O'Brien, T.P.; Rawlingson, M.

    1978-06-01

    A basic experimental programme involving the sudden depressurisation of a simple pipe system containing water at 3.45 to 17.24MPa pressure and temperature in the range of 200 to 250 0 C has been concluded. Measurements were made of the transient density, pressure, and temperature variations in a two phase fluid in the system during discharge. Phase 1 tests investigated blowdown from straight pipes 4m long with constant internal diameters of 73 and 32 mm. Phase 2 tests incorporated a reservoir added to the 32mm pipe. In this, the second of three reports on Phase 2 tests, the test assembly, instrumentation and experimental procedure are briefly described. The conditions and results are reported for two of the tests in which the liquid in the long discharge pipe was initially subcooled by 10 0 C and 15 0 C while the reservoir was at saturation conditions with a steam dome present. (UK)

  18. FUMEX cases 1, 2, and 3 calculated pre-test and post-test results

    Energy Technology Data Exchange (ETDEWEB)

    Stefanova, S; Vitkova, M; Passage, G; Manolova, M; Simeonova, V [Bylgarska Akademiya na Naukite, Sofia (Bulgaria). Inst. za Yadrena Izsledvaniya i Yadrena Energetika; Scheglov, A; Proselkov, V [Russian Research Centre Kurchatov Inst., Moscow (Russian Federation); Kharalampieva, Ts [Kombinat Atomna Energetika, Kozloduj (Bulgaria)

    1994-12-31

    Two versions (modified pre-test and modified post-test) of PIN-micro code were used to analyse the fuel rod behaviour of three FUMEX experiments. The experience of applying PIN-micro code with its simple structure and old conception of the steady-state operation shows significant difficulties in treating the complex processes like those in FUMEX experiments. These difficulties were partially overcame through different model modifications and corrections based on special engineering estimations and the results obtained as a whole do not seem unreasonable. The calculations have been performed by a group from two Bulgarian institutions in collaboration with specialists from the Kurchatov Research Center. 1 tab., 14 figs., 8 refs.

  19. Final report on special impact tests of plutonium shipping containers description of test results

    International Nuclear Information System (INIS)

    Bonzon, L.L.

    1977-02-01

    The results from tests conducted to determine the structural response of the LLD-1, Model 1518-6M, and FL-10 plutonium shipping packages when subjected to high-speed impacts (170 to 760 ft/sec) onto unyielding, concrete, and soil targets are presented

  20. DART Core/Combustor-Noise Initial Test Results

    Science.gov (United States)

    Boyle, Devin K.; Henderson, Brenda S.; Hultgren, Lennart S.

    2017-01-01

    Contributions from the combustor to the overall propulsion noise of civilian transport aircraft are starting to become important due to turbofan design trends and advances in mitigation of other noise sources. Future propulsion systems for ultra-efficient commercial air vehicles are projected to be of increasingly higher bypass ratio from larger fans combined with much smaller cores, with ultra-clean burning fuel-flexible combustors. Unless effective noise-reduction strategies are developed, combustor noise is likely to become a prominent contributor to overall airport community noise in the future. The new NASA DGEN Aero0propulsion Research Turbofan (DART) is a cost-efficient testbed for the study of core-noise physics and mitigation. This presentation gives a brief description of the recently completed DART core combustor-noise baseline test in the NASA GRC Aero-Acoustic Propulsion Laboratory (AAPL). Acoustic data was simultaneously acquired using the AAPL overhead microphone array in the engine aft quadrant far field, a single midfield microphone, and two semi-infinite-tube unsteady pressure sensors at the core-nozzle exit. An initial assessment shows that the data is of high quality and compares well with results from a quick 2014 feasibility test. Combustor noise components of measured total-noise signatures were educed using a two-signal source-separation method an dare found to occur in the expected frequency range. The research described herein is aligned with the NASA Ultra-Efficient Commercial Transport strategic thrust and is supported by the NASA Advanced Air Vehicle Program, Advanced Air Transport Technology Project, under the Aircraft Noise Reduction Subproject.

  1. Spent fuel drying system test results (second dry-run)

    International Nuclear Information System (INIS)

    Klinger, G.S.; Oliver, B.M.; Abrefah, J.; Marschman, S.C.; MacFarlan, P.J.; Ritter, G.A.

    1998-07-01

    The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks have been detected in the basins and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site (WHC 1995). Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL) on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of the second dry-run test, which was conducted without a fuel element. With the concurrence of project management, the test protocol for this run, and subsequent drying test runs, was modified. These modifications were made to allow for improved data correlation with drying procedures proposed under the IPS. Details of these modifications are discussed in Section 3.0

  2. Hydrologic testing methodology and results from deep basalt boreholes

    International Nuclear Information System (INIS)

    Strait, S.R.; Spane, F.A.; Jackson, R.L.; Pidcoe, W.W.

    1982-05-01

    The objective of the hydrologic field-testing program is to provide data for characterization of the groundwater systems wihin the Pasco Basin that are significant to understanding waste isolation. The effort is directed toward characterizing the areal and vertical distributions of hydraulic head, hydraulic properties, and hydrochemistry. Data obtained from these studies provide input for numerical modeling of groundwater flow and solute transport. These models are then used for evaluating potential waste migration as a function of space and time. The groundwater system beneath the Hanford Site and surrounding area consists of a thick, accordantly layered sequence of basalt flows and associated sedimentary interbed that primarily occur in the upper part of the Columbia River basalt. Permeable horizons of the sequence are associated with the interbeds and the interflow zones within the basalt. The columnar interiors of a flow act as low-permeability aquitards, separating the more-permeable interflows or interbeds. This paper discusses the hydrologic field-gathering activities, specifically, field-testing methodology and test results from deep basalt boreholes

  3. Relating results from earthworm toxicity tests to agricultural soil

    Science.gov (United States)

    Beyer, W.N.; Greig-Smith, P.W.

    1992-01-01

    The artificial soil tests of the European Economic Community and of the Organization for Economic Cooperation produce data relating earthworm mortality to pesticide concentrations in soil under laboratory conditions. To apply these results to agricultural soils it is necessary to relate these concentrations to amounts of pesticide applied per area. This paper reviews the relevant published literature and suggests a simple relation for regulatory use. Hazards to earthworms from pesticides are suggested to be greatest soon after application, when the pesticides may be concentrated in a soil layer a few millimeters thick. For estimating exposure of earthworms, however, a thicker soil layer should be considered, to account for their movement through soil. During favorable weather conditions, earthworms belonging to species appropriate to the artificial soil test have been reported to confine their activity to a layer about 5 cm. If a 5-cm layer is accepted as relevant for regulatory purposes, then an application of 1 kg/ha would be equivalent to 1-67 ppm (dry) in the artificial soil test.

  4. Test results of reliable and very high capillary multi-evaporators / condenser loop

    Energy Technology Data Exchange (ETDEWEB)

    Van Oost, S; Dubois, M; Bekaert, G [Societe Anonyme Belge de Construction Aeronautique - SABCA (Belgium)

    1997-12-31

    The paper present the results of various SABCA activities in the field of two-phase heat transport system. These results have been based on a critical review and analysis of the existing two-phase loop and of the future loop needs in space applications. The research and the development of a high capillary wick (capillary pressure up to 38 000 Pa) are described. These activities have led towards the development of a reliable high performance capillary loop concept (HPCPL), which is discussed in details. Several loop configurations mono/multi-evaporators have been ground tested. The presented results of various tests clearly show the viability of this concept for future applications. Proposed flight demonstrations as well as potential applications conclude this paper. (authors) 7 refs.

  5. Test results of reliable and very high capillary multi-evaporators / condenser loop

    Energy Technology Data Exchange (ETDEWEB)

    Van Oost, S.; Dubois, M.; Bekaert, G. [Societe Anonyme Belge de Construction Aeronautique - SABCA (Belgium)

    1996-12-31

    The paper present the results of various SABCA activities in the field of two-phase heat transport system. These results have been based on a critical review and analysis of the existing two-phase loop and of the future loop needs in space applications. The research and the development of a high capillary wick (capillary pressure up to 38 000 Pa) are described. These activities have led towards the development of a reliable high performance capillary loop concept (HPCPL), which is discussed in details. Several loop configurations mono/multi-evaporators have been ground tested. The presented results of various tests clearly show the viability of this concept for future applications. Proposed flight demonstrations as well as potential applications conclude this paper. (authors) 7 refs.

  6. Pipe rupture test results: 4-inch pipe whip tests under PWR LOCA conditions

    International Nuclear Information System (INIS)

    Miyazaki, Noriyuki; Ueda, Shuzo; Isozaki, Toshikuni; Kato, Rokuro; Kurihara, Ryoichi; Yano, Toshikazu; Miyazono, Shohachiro

    1982-09-01

    This report summarizes the results of 4-inch pipe whip tests (RUN No. 5506, 5507, 5508 and 5604) under the PWR LOCA conditions. The dynamic behaviors of the test pipe and restraints were studied in the tests. In the tests, the gap between the test pipe and the restraints was kept at the constant value of 8.85 mm and the overhang length was varied from 250 mm to 650 mm. The dynamic behaviors of the test pipe and the restraint were made clear by the outputs of strain gages and the measurements of residual deformations. The data of water hammer in subcooled water were also obtained by the pressure transducers mounted on the test pipe. The main conclusions obtained from the tests are as follows. (1) The whipping of pipe can be prevented more effectively as the overhang length becomes shorter. (2) The load acting on the restraint-support structure becomes larger as the overhang length becomes shorter. (3) The restraint farther from the break location does not limit the pipe movement except for the first impact when the overhang length is long. (4) The ultimate moment M sub(u) of the pipe at the restraint location can be used to predict the plastic collapse of the whipping pipe. (5) The restraints slide along the pipe axis and are subjected to bending moment, when the overhang length is long. (author)

  7. Results of Testing the Relative Oxidizing Hazard of Wipes and KMI Zeolite

    Energy Technology Data Exchange (ETDEWEB)

    Ams, Bridget Elaine [Los Alamos National Laboratory

    2017-05-09

    This report includes the results from testing performed on the relative oxidizing hazard of a number of organic sorbing wipe materials, as well as KMI zeolite. These studies were undertaken to address a need by the Los Alamos National Laboratory (LANL) Hazardous Materials Management group, which requires a material that can sorb small spills in a glovebox without creating a disposal hazard due to the potential for oxidation reactions, as requested in Request for Testing of Wipes and Zeolite for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-002) and Request for Testing of Chamois Material for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-005). This set oftests is a continuation of previous testing described in Results from Preparation and Testing of Sorbents Mixed with (DWT-RPT-003), which provided data for the Waste Isolation Pilot Plant's Basis of Knowledge. The Basis of Knowledge establishes criteria for evaluating transuranic (TRU) waste that contains oxidizing chemicals.

  8. Results of thermal test of metallic molybdenum disk target and fast-acting valve testing

    Energy Technology Data Exchange (ETDEWEB)

    Virgo, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Gromov, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Jonah, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, G. F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    This report describes the irradiation conditions for thermal testing of helium-cooled metallic disk targets that was conducted on March 9, 2016, at the Argonne National Laboratory electron linac. The four disks in this irradiation were pressed and sintered by Oak Ridge National Laboratory from molybdenum metal powder. Two of those disks were instrumented with thermocouples. Also reported are results of testing a fast-acting-valve system, which was designed to protect the accelerator in case of a target-window failure.

  9. 75 FR 32484 - Array-Based Cytogenetic Tests: Questions on Performance Evaluation, Result Reporting and...

    Science.gov (United States)

    2010-06-08

    ...] Array-Based Cytogenetic Tests: Questions on Performance Evaluation, Result Reporting and Interpretation... public meeting: Array-Based Cytogenetic Tests: Questions on Performance Evaluation, Result Reporting and... cytogenetic tests. Date and Time: The meeting will be held on June 30, 2010, from 1:30 p.m. to 5 p.m. Location...

  10. Fatigue test results of straight pipe with flaws in inner surface

    International Nuclear Information System (INIS)

    Shibata, Katsuyuki; Oba, Toshihiro; Kawamura, Takaichi; Yokoyama, Norio; Miyazono, Shohachiro

    1981-01-01

    Fatigue and fracture tests of piping models with flaws in the inner surface were carried out to investigate the fatigue crack growth, coalescence of multiple cracks and fracture behavior. Two straight test pipes with and without weldment in the test section of SUS304L stainless steel were tested under almost the same test conditions. Three artificial defects were machined in the inner surface of the test section of the test pipes. The fatigue test were performed untill the cracks coalesced and grew through the thickness. Subsequently, a static load was imposed on test pipe which contained a large crack in the test section. The test results show that the fatigue crack growth is slower than that predicted by the method specified in the Section XI of ASME Boiler and Pressure Vessel Code, and that the test pipes can endure more than the static load of 3Sm without an unstable fracture. (author)

  11. Understanding of BRCA1/2 genetic tests results: the importance of objective and subjective numeracy.

    Science.gov (United States)

    Hanoch, Yaniv; Miron-Shatz, Talya; Rolison, Jonathan J; Ozanne, Elissa

    2014-10-01

    The majority of women (71%) who undergo BRCA1/2 testing-designed to identify genetic mutations associated with increased risk of cancer-receive results that are termed 'ambiguous' or 'uninformative negative'. How women interpret these results and the association with numerical ability was examined. In this study, 477 women at increased risk for breast and ovarian cancer were recruited via the Cancer Genetics Network. They were presented with information about the four different possible BRCA1/2 test results-positive, true negative, ambiguous and uninformative negative-and asked to indicate which of six options represents the best response. Participants were then asked which treatment options they thought a woman receiving the results should discuss with her doctor. Finally, participants completed measures of objective and subjective numeracy. Almost all of the participants correctly interpreted the positive and negative BRCA1/2 genetic test results. However, they encountered difficulties interpreting the uninformative and ambiguous BRCA1/2 genetic test results. Participants were almost equally likely to think either that the woman had learned nothing from the test result or that she was as likely to develop cancer as the average woman. Highly numerate participants were more likely to correctly interpret inconclusive test results (ambiguous, OR = 1.62; 95% CI [1.28, 2.07]; p psychological ramifications of genetic testing, healthcare professionals should consider devoting extra effort to ensuring proper comprehension of ambiguous and uninformative negative test results by women. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Summary of ROSA-4 LSTF first phase test program and station blackout (TMLB) test results

    International Nuclear Information System (INIS)

    Tasaka, K.; Kukita, Y.; Anoda, Y.

    1990-01-01

    This paper summarizes major test results obtained at the ROSA-4 Large Scale Test Facility (LSTF) during the first phase of the test program. The results from a station blackout (TMLB) test conducted at the end of the first-phase program are described in some detail. The LSTF is an integral test facility being operated by the Japan Atomic Energy Research Institute for simulation of pressurized water reactor (PWR) thermal-hydraulic responses during small-break loss-of-coolant accidents (SBLOCAs) and operational/abnormal transients. It is a 1/48 volumetrically scaled, full-height, full-pressure simulator of a Westinghouse-type 4-loop PWR. The facility includes two symmetric primary loops each one containing an active inverted-U tube steam generator and an active reactor coolant pump. The loop horizontal legs are sized to conserve the scaled (1/24) volumes as well as the length to the square root of the diameter ratio in order to simulate the two-phase flow regime transitions. The primary objective of the LSTF first-phase program was to define the fundamental PWR thermal-hydraulic responses during SBLOCAs and transients. Most of the tests were conducted with simulated component/operator failures, including unavailability of the high pressure injection system and auxiliary feedwater system, as well as operator failure to take corrective actions. The forty-two first phase tests included twenty-nine SBLOCA tests conducted mainly for cold leg breaks, three abnormal transient tests and ten natural circulation tests. Attempts were made in several of the SBLOCA tests to simulate the plant recovery procedures as well as candidate accident management measures for prevention of high-pressure core melt situation. The natural circulation tests simulated the single-phase and two-phase natural circulation as well as reflux condensation behavior in the primary loops in steady or quasi-steady states

  13. CUSUM-Logistic Regression analysis for the rapid detection of errors in clinical laboratory test results.

    Science.gov (United States)

    Sampson, Maureen L; Gounden, Verena; van Deventer, Hendrik E; Remaley, Alan T

    2016-02-01

    The main drawback of the periodic analysis of quality control (QC) material is that test performance is not monitored in time periods between QC analyses, potentially leading to the reporting of faulty test results. The objective of this study was to develop a patient based QC procedure for the more timely detection of test errors. Results from a Chem-14 panel measured on the Beckman LX20 analyzer were used to develop the model. Each test result was predicted from the other 13 members of the panel by multiple regression, which resulted in correlation coefficients between the predicted and measured result of >0.7 for 8 of the 14 tests. A logistic regression model, which utilized the measured test result, the predicted test result, the day of the week and time of day, was then developed for predicting test errors. The output of the logistic regression was tallied by a daily CUSUM approach and used to predict test errors, with a fixed specificity of 90%. The mean average run length (ARL) before error detection by CUSUM-Logistic Regression (CSLR) was 20 with a mean sensitivity of 97%, which was considerably shorter than the mean ARL of 53 (sensitivity 87.5%) for a simple prediction model that only used the measured result for error detection. A CUSUM-Logistic Regression analysis of patient laboratory data can be an effective approach for the rapid and sensitive detection of clinical laboratory errors. Published by Elsevier Inc.

  14. Surprising results: HIV testing and changes in contraceptive practices among young women in Malawi

    Science.gov (United States)

    Sennott, Christie; Yeatman, Sara

    2015-01-01

    This study uses eight waves of data from the population-based Tsogolo la Thanzi study (2009–2011) in rural Malawi to examine changes in young women’s contraceptive practices, including the use of condoms, non-barrier contraceptive methods, and abstinence, following positive and negative HIV tests. The analysis factors in women’s prior perceptions of their HIV status that may already be shaping their behaviour and separates surprise HIV test results from those that merely confirm what was already believed. Fixed effects logistic regression models show that HIV testing frequently affects the contraceptive practices of young Malawian women, particularly when the test yields an unexpected result. Specifically, women who are surprised to test HIV positive increase their condom use and are more likely to use condoms consistently. Following an HIV negative test (whether a surprise or expected), women increase their use of condoms and decrease their use of non-barrier contraceptives; the latter may be due to an increase in abstinence following a surprise negative result. Changes in condom use following HIV testing are robust to the inclusion of potential explanatory mechanisms including fertility preferences, relationship status, and the perception that a partner is HIV positive. The results demonstrate that both positive and negative tests can influence women’s sexual and reproductive behaviours, and emphasise the importance of conceptualizing of HIV testing as offering new information only insofar as results deviate from prior perceptions of HIV status. PMID:26160156

  15. High-power circulator test results at 350 and 700 MHz

    International Nuclear Information System (INIS)

    Roybal, W.; Bradley, J.T.; Rees, D.E.

    2000-01-01

    The high-power RF systems for the Accelerator Production of Tritium (APT) program require high-power circulators at 350 MHz and 700 MHz to protect 1 MW Continuous Wave (CW) klystrons from reflected power. The 350 MHz circulator is based on the CERN, EXF, and APS designs and has performed very well. The 700 MHz circulator is a new design. Prototype 700 MHz circulators have been high-power tested at Los Alamos National Laboratory (LANL). The first of these circulators has satisfied performance requirements. The circulator requirements, results from the testing, and lessons learned from this development are presented and discussed

  16. Selected Test Results from the Encell Technology Nickel Iron Battery

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Summer Kamal Rhodes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Baca, Wes Edmund [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Avedikian, Kristan [Encell Technology, Alachua, FL (United States)

    2014-09-01

    The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

  17. Hanford coring bit temperature monitor development testing results report

    International Nuclear Information System (INIS)

    Rey, D.

    1995-05-01

    Instrumentation which directly monitors the temperature of a coring bit used to retrieve core samples of high level nuclear waste stored in tanks at Hanford was developed at Sandia National Laboratories. Monitoring the temperature of the coring bit is desired to enhance the safety of the coring operations. A unique application of mature technologies was used to accomplish the measurement. This report documents the results of development testing performed at Sandia to assure the instrumentation will withstand the severe environments present in the waste tanks

  18. North American Contact Dermatitis Group patch test results: 2009 to 2010.

    Science.gov (United States)

    Warshaw, Erin M; Belsito, Donald V; Taylor, James S; Sasseville, Denis; DeKoven, Joel G; Zirwas, Matthew J; Fransway, Anthony F; Mathias, C G Toby; Zug, Kathryn A; DeLeo, Vincent A; Fowler, Joseph F; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Maibach, Howard I

    2013-01-01

    Patch testing is an important diagnostic tool for determination of substances responsible for allergic contact dermatitis. This study reports the North American Contact Dermatitis Group (NACDG) patch testing results from January 1, 2009, to December 31, 2010. At 12 centers in North America, patients were tested in a standardized manner with a screening series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends were analyzed using χ2 statistics. A total of 4308 patients were tested. Of these, 2614 (60.7%) had at least 1 positive reaction, and 2284 (46.3%) were ultimately determined to have a primary diagnosis of allergic contact dermatitis. Four hundred twenty-seven (9.9%) patients had occupationally related skin disease. There were 6855 positive allergic reactions. As compared with the previous reporting period (2007-2008), the positive reaction rates statistically decreased for 20 allergens (nickel, neomycin, Myroxylon pereirae, cobalt, formaldehyde, quaternium 15, methydibromoglutaronitrile/phenoxyethanol, methylchlorisothiazolinone/methylisothiazolinone, potassium dichromate, diazolidinyl urea, propolis, dimethylol dimethylhydantoin, 2-bromo-2-nitro-1,3-propanediol, methyl methacrylate, ethyl acrylate, glyceryl thioglycolate, dibucaine, amidoamine, clobetasol, and dimethyloldihydroxyethyleneurea; P < 0.05) and statistically increased for 4 allergens (fragrance mix II, iodopropynyl butylcarbamate, propylene glycol, and benzocaine; P < 0.05). Approximately one quarter of tested patients had at least 1 relevant allergic reaction to a non-NACDG allergen. Hypothetically, approximately one quarter of reactions detected by NACDG allergens would have been missed by TRUE TEST (SmartPractice Denmark, Hillerød, Denmark). These results affirm the value of patch testing with many allergens.

  19. The Estimation of Knowledge Solidity Based on the Comparative Analysis of Different Test Results

    Directory of Open Access Journals (Sweden)

    Y. K. Khenner

    2012-01-01

    Full Text Available At present, the testing techniques of knowledge estimation are widely spread in educational system. However, this method is seriously criticized including its application to the Unified State Examinations. The research is aimed at studying the limitations of testing techniques. The authors recommend a new way of knowledge solid- ity estimation bases on the comparative results analysis of various kinds of tests. While testing the large group of students, the authors found out that the results of the closed and open tests substantially differ. The comparative analysis demonstrates that the open tests assessment of the knowledge solidity is more adequate than that of the closed ones. As the research is only based on a single experiment, the authors recommend using this method further, substantiating the findings concerning the differences in tests results, and analyzing the advantages and disadvantages of the tests in question. 

  20. Railgun bore material test results

    International Nuclear Information System (INIS)

    Wang, S.Y.; Burton, R.L.; Witherspoon, F.D.; Bloomberg, H.W.; Goldstein, S.A.; Tidman, D.A.; Winsor, N.K.

    1987-01-01

    GT-Devices, Inc. has constructed a material test facility (MTF) to study the fundamental heat transfer problem of both railgun and electrothermal guns, and to test candidate gun materials under real plasma conditions. The MTF electrothermally produces gigawatt-level plasmas with pulse lengths of 10-30 microseconds. Circular bore and non-circular bore test barrels have been successfully operated under a wide range of simulated heating environments for EM launchers. Diagnostics include piezoelectric MHz pressure probes, time-of-flight probes, and current and voltage probes. Ablation measurements are accomplished by weighing and optical inspection, including borescope, optical microscope, and scanning electron microscope (SEM). From these measurements the ablation threshold for both the rail and insulator materials can be determined as a function of plasma heating. The MTF diagnostics are supported by an unsteady 1-D model of MTF which uses the flux-corrected transport (FCT) algorithm to calculate the fluid equations in conservative form. A major advantage of the FCT algorithm is that it can model gas dynamic shock behaviour without the requirement of numerical diffusion. The principle use of the code is to predict the material surface temperature ΔT/α from the unsteady heat transfer q(t)

  1. Results from phase 2 of the radioiodine test facility experimental program

    Energy Technology Data Exchange (ETDEWEB)

    Ball, J M; Kupferschmid, W C.H.; Wren, J C [Atomic Energy of Canada Ltd., Pinawa, MB (Canada). Whiteshell Labs.

    1996-12-01

    A series of intermediate-scale experiments were conducted in the Radioiodine Test Facility (RTF) in a vinyl-painted, zinc-primer coated, carbon steel vessel in order to assess the effects of vinyl surfaces on iodine volatility in both the presence and absence of radiation. This test series, Phase 2 of a larger, comprehensive program assessing a variety of containment surfaces, also examined the effects of organic (i.e., methyl ethyl ketone) and inorganic (i.e., hydrazine) additives, pH, and venting on the aqueous chemistry and volatility of solutions initially containing cesium iodide. These tests have clearly demonstrated that organics are released to the aqueous phase from the vinyl coating and that, under radiation conditions, these organics can have a significant effect on the formation of volatile iodine species. In particular, the RTF results suggest that radiolytic decomposition of the released organics results in dramatic reductions in pH and dissolved oxygen concentration, which in turn are responsible for increased formation of molecular iodine and organic iodides. When the pH was maintained at 10 (Test 3), much lower iodine volatility was observed; low iodine volatility was also observed in the absence of radiation. This test series also demonstrated that vinyl surfaces, particularly those in contact with the gas phase, were a sink for iodine. (author) 4 figs., 6 tabs., 17 refs.

  2. Results from phase 2 of the radioiodine test facility experimental program

    International Nuclear Information System (INIS)

    Ball, J.M.; Kupferschmid, W.C.H.; Wren, J.C.

    1996-01-01

    A series of intermediate-scale experiments were conducted in the Radioiodine Test Facility (RTF) in a vinyl-painted, zinc-primer coated, carbon steel vessel in order to assess the effects of vinyl surfaces on iodine volatility in both the presence and absence of radiation. This test series, Phase 2 of a larger, comprehensive program assessing a variety of containment surfaces, also examined the effects of organic (i.e., methyl ethyl ketone) and inorganic (i.e., hydrazine) additives, pH, and venting on the aqueous chemistry and volatility of solutions initially containing cesium iodide. These tests have clearly demonstrated that organics are released to the aqueous phase from the vinyl coating and that, under radiation conditions, these organics can have a significant effect on the formation of volatile iodine species. In particular, the RTF results suggest that radiolytic decomposition of the released organics results in dramatic reductions in pH and dissolved oxygen concentration, which in turn are responsible for increased formation of molecular iodine and organic iodides. When the pH was maintained at 10 (Test 3), much lower iodine volatility was observed; low iodine volatility was also observed in the absence of radiation. This test series also demonstrated that vinyl surfaces, particularly those in contact with the gas phase, were a sink for iodine. (author) 4 figs., 6 tabs., 17 refs

  3. Results of the First Performance Tests of the CMS Electromagnetic Calorimeter

    CERN Document Server

    Adzic, Petar; Almeida, Carlos; Almeida, Nuno; Anagnostou, Georgios; Anfreville, Marc; Anicin, Ivan; Antunovic, Zeljko; Asimidis, Asimakis; Auffray, Etiennette; Baccaro, Stefania; Barney, David; Barone, Luciano; Barrillon, Pierre; Bartoloni, Alessandro; Beauceron, Stephanie; Beaudette, Florian; Bell, Ken W; Benetta, Robert; Bercher, Michel; Beteva, B; Beuselinck, Raymond; Bhardwa, A; Biino, Cristina; Bimbot, Stephane; Bloch, Philippe; Blyth, Simon; Bonesini, Maurizio; Bordalo, Paula; Bornheim, Adolf; Bourotte, Jean; Britton, David; Brown, Robert M; Brunelière, Renaud; Busson, Philippe; Camporesi, Tiziano; Cartiglia, Nicolo; Cavallari, Francesca; Chamont, David; Chang, Paoti; Chang, You-Hao; Charlot, Claude; Chen, E Augustine; Chipaux, Rémi; Cockerill, David J A; Collard, Caroline; Combaret, Christophe; Costantini, Silvia; Da Silva, J C; Dafinei, Ioan; Daskalakis, Georgios; Davatz, Giovanna; De Min, Alberto; Deiters, Konrad; Dejardin, Marc; Della Negra, Rodolphe; Depasse, Pierre; Descamp, J; Dewhirst, Guy; Dhawan, Satish; Diemoz, Marcella; Dissertori, Günther; Dittmar, Michael; Djambazov, Lubomir; Dobrzynski, Ludwik; Drndarevic, Snezana; Dupanloup, Michel; Dzelalija, Mile; Ehlers, Jan; El-Mamouni, H; Peisert, Anna; Evangelou, Ioannis; Fabbro, Bernard; Faure, Jean-Louis; Fay, Jean; Ferri, Federico; Flower, Paul S; Franzoni, Giovanni; Funk, Wolfgang; Gaillac, Anne-Marie; Gargiulo, Corrado; Gascon-Shotkin, S; Geerebaert, Yannick; Gentit, François-Xavier; Ghezzi, Alessio; Gilly, Jean; Giolo-Nicollerat, Anne-Sylvie; Givernaud, Alain; Gninenko, Sergei; Go, Apollo; Godinovic, Nikola; Golubev, Nikolai; Gómez-Reino, Robert; Govoni, Pietro; Grahl, James; Gras, Philippe; Greenhalgh, Justin; Guillaud, Jean-Paul; Haguenauer, Maurice; Hamel De Montechenault, G; Hansen, Magnus; Heath, Helen F; Hill, Jack; Hobson, Peter R; Holmes, Daniel; Holzner, André; Hou, George Wei-Shu; Ille, Bernard; Ingram, Quentin; Jain, Adarsh; Janot, Patrick; Jarry, Patrick; Karar, M A; Kataria, Sushil Kumar; Katchanov, V A; Kennedy, Bruce W; Kloukinas, Kostas; Koblitz, Birger; Kokkas, Panagiotis; Korjik, M; Krasnikov, Nikolai; Krpic, Dragomir; Kyriakis, Aristotelis; Lebeau, Michel; Lecomte, Pierre; Lecoq, Paul; Lemaire, Marie-Claude; Lethuillier, Morgan; Lin, Willis; Lintern, A L; Lister, Alison; Locci, Elizabeth; Lodge, Anthony B; Longo, Egidio; Loukas, Demetrios; Lustermann, Werner; Lynch, Clare; MacKay, Catherine Kirsty; Maletic, Dimitrije; Mandjavidze, Irakli; Manthos, Nikolaos; Markou, Athanasios; Mathez, Hervé; Matveev, Viktor; Maurelli, Georges; Menichetti, Ezio; Meridiani, Paolo; Milenovic, Predrag; Milleret, Gérard; Miné, Philippe; Montecchi, Marco; Mur, Michel; Musienko, Yuri; Nardulli, Alessandro; Nash, Jordan; Neal, Homer; Nédélec, Patrick; Negri, Pietro; Nessi-Tedaldi, Francesca; Newman, Harvey B; Nikitenko, Alexander; Obertino, Maria Margherita; Ofierzynski, Radoslaw Adrian; Organtini, Giovanni; Paganini, Pascal; Paganoni, Marco; Papadopoulos, Ioannis; Paramatti, Riccardo; Pastrone, Nadia; Pauss, Felicitas; Poilleux, Patrick; Puljak, Ivica; Pullia, Antonino; Puzovic, Jovan; Ragazzi, Stefano; Ramos, Sergio; Rander, John; Ravat, Olivier; Raymond, M; Razis, Panos A; Redaelli, Nicola; Regnault, Nicolas; Renker, Dieter; Reucroft, Steve; Reymond, Jean-Marc; Reynaud, Michel; Reynaud, Serge; Romanteau, Thierry; Rondeaux, Françoise; Rosowsky, André; Rovelli, Chiara; Rusack, Roger; Rusakov, Sergey V; Ryan, Matthew John; Rykaczewski, Hans; Sakhelashvili, Tariel; Salerno, Roberto; Santos, Marcelino; Schinzel, Dietrich; Seez, Christopher; Semeniouk, Igor; Sempere-Roldan, P; Sharif, Omar; Sharp, Peter; Shepherd-Themistocleous, Claire; Shevchenko, Sergey; Shivpuri, Ram Krishen; Sidiropoulos, Georgios; Sillou, Daniel; Singovsky, Alexander; Sirois, Yves; Sirunyan, Albert M; Smith, Brian; Smith, Vincent J; Sproston, Martin; Suter, Henry; Swain, John; Tabarelli de Fatis, Tommaso; Takahashi, Maiko; Tapper, Robert J; Tcheremoukhine, Alexandre; Teixeira, Isabel; Teixeira, Joao Paulo; Teller, Olivier; Triantis, Frixos A; Troshin, Sergey; Tyurin, Nikolay; Udriot, Stève; Ueno, Koji; Uzunian, Andrey; Van Vulpen, Ivo; Varela, Joao; Vaz-Cardoso, N; Verrecchia, Patrice; Vichoudis, Paschalis; Viertel, Gert; Virdee, Tejinder; Wang, Minzu; Williams, Jennifer C; Yaselli, Ignacio; Zamiatin, Nikolai; Zelepoukine, Serguei; Zeller, Michael E; Zhang, Lin; Zhu, Kejun; Zhu, Ren-Yuan

    2006-01-01

    Performance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to validate prototypes of the new Very Front End electronics. The final versions of the monitoring and cooling systems, and of the high and low voltage regulation were used in these tests. The results are consistent with the performance targets including those for noise and overall energy resolution, required to fulfil the physics programme of CMS at the LHC.

  4. Long-life fatigue test results for two nickel-base structural alloys

    International Nuclear Information System (INIS)

    Mowbray, D.F.; Giaquinto, E.V.; Mehringer, F.J.

    1978-11-01

    The results are reported of fatigue tests on two nickel--base alloys, hot-cold-worked and stress-relieved nickel--chrome--iron Alloy 600 and mill-annealed nickel--chrome--moly--iron Alloy 625 in which S-N data were obtained in the life range of 10 6 to 10 10 cycles. The tests were conducted in air at 600 0 F, in the reversed membrane loading mode, at a frequency of approx. 1850 Hz. An electromagnetic, closed loop servo-controlled machine was built to perform the tests. A description of the machine is given

  5. Support Seeking or Familial Obligation: An Investigation of Motives for Disclosing Genetic Test Results.

    Science.gov (United States)

    Greenberg, Marisa; Smith, Rachel A

    2016-01-01

    Genetic test results reveal not only personal information about a person's likelihood of certain medical conditions but also information about the person's genetic relatives. Given the familial nature of genetic information, one's obligation to protect family members may be a motive for disclosing genetic test results, but this claim has not been methodically tested. Existing models of disclosure decision making presume self-interested motives, such as seeking social support, instead of other-interested motives, like familial obligation. This study investigated young adults' (N = 173) motives to share a genetic-based health condition, alpha-1 antitrypsin deficiency, after reading a hypothetical vignette. Results show that social support and familial obligation were both reported as motives for disclosure. In fact, some participants reported familial obligation as their primary motivator for disclosure. Finally, stronger familial obligation predicted increased likelihood of disclosing hypothetical genetic test results. Implications of these results were discussed in reference to theories of disclosure decision-making models and the practice of genetic disclosures.

  6. 75 Ah and 10 boilerplate nickel-hydrogen battery designs and test results

    Science.gov (United States)

    Daman, M. E.; Manzo, Michelle A.; Chang, R.; Cruz, E.

    1992-01-01

    The results of initial characterization testing of 75 Ah actively cooled bipolar battery designs and 10 boilerplate nickel-hydrogen battery designs are presented. The results demonstrate the extended cycle life capability of the Ah batteries and the high capacity utilizations at various discharge rates of the nickel-hydrogen batteries.

  7. Major Results of SBLOCA Tests with VISTA-ITL for the SMART Design

    International Nuclear Information System (INIS)

    Park, Hyun Sik; Min, Byoung Yeon; Shin, Yong Chul; Choi, Nam Hyun; Chung, Young Jong; Lee, Won Jae; Yi, Sung Jae

    2012-01-01

    A thermal-hydraulic integral effect test facility, VISTAITL, for the SMART design has been constructed by the Korea Atomic Energy Research Institute (KAERI). The VISTA-ITL has the simulation capability of small break loss of coolant accident (SBLOCA), passive residual heat removal system (PRHRS) performance, and complete loss of RCS (Reactor Coolant System) flowrate (CLOF), etc. The VISTA-ITL is a 1/2.77- height and 1/1310-volume scaled test facility based on the design features of SMART. The reference scale ratios of length (1/2.77) and area (1/472.9) are based on the elevation difference between the core and steam generator centers and the core flow area, respectively. According to the scaling law, the reduced height scaling results in time reducing results in the model and the time scale ratio is 1/1.664. Three SBLOCA tests of safety injection system (SIS) line break, shutdown cooling system (SCS) line break and pressurizer safety valve (PSV) line break were successfully performed and its major results have been compared and discussed in this paper

  8. Improved PFB operations - 400-hour turbine test results. [Pressurized Fluidized Bed

    Science.gov (United States)

    Rollbuhler, R. J.; Benford, S. M.; Zellars, G. R.

    1980-01-01

    The paper deals with a 400-hr small turbine test in the effluent of a pressurized fluidized bed (PFB) at an average temperature of 770 C, an average relative gas velocity of 300 m/sec, and average solid loadings of 200 ppm. Consideration is given to combustion parameters and operating procedure as well as to the turbine system and turbine test operating procedures. Emphasis is placed on erosion/corrosion results.

  9. 49 CFR 655.61 - Action when an employee has a verified positive drug test result or has a confirmed alcohol test...

    Science.gov (United States)

    2010-10-01

    ... drug test result or has a confirmed alcohol test result of 0.04 or greater, or refuses to submit to a... drug test result or has a confirmed alcohol test result of 0.04 or greater, or refuses to submit to a... performing a safety-sensitive function. (3) If an employee refuses to submit to a drug or alcohol test...

  10. IMAGE Project: Results of Laboratory Tests on Tracers for Supercritical Conditions.

    Science.gov (United States)

    Brandvoll, Øyvind; Opsahl Viig, Sissel; Nardini, Isabella; Muller, Jiri

    2016-04-01

    The use of tracers is a well-established technique for monitoring dynamic behaviour of water and gas through a reservoir. In geothermal reservoirs special challenges are encountered due to high temperatures and pressures. In this work, tracer candidates for monitoring water at supercritical conditions (temperature > 374°C, pressure ca 218 bar), are tested in laboratory experiments. Testing of tracers at supercritical water conditions requires experimental set-ups which tolerate harsh conditions with respect to high temperature and pressure. In addition stringent HES (health, environment and safety) factors have to be taken into consideration when designing and performing the experiments. The setup constructed in this project consists of a pressure vessel, high pressure pump, instrumentation for pressure and temperature control and instrumentation required for accurate sampling of tracers. In order to achieve accurate results, a special focus has been paid to the development of the tracer sampling technique. Perfluorinated cyclic hydrocarbons (PFCs) have been selected as tracer candidates. This group of compounds is today commonly used as gas tracers in oil reservoirs. According to the literature they are stable at temperatures up to 400°C. To start with, five PFCs have been tested for thermal stability in static experiments at 375°C and 108 bar in the experimental setup described above. The tracer candidates will be further tested for several months at the relevant conditions. Preliminary results indicate that some of the PFC compounds show stability after three months. However, in order to arrive at conclusive results, the experiments have to be repeated over a longer period and paying special attention to more accurate sampling procedures.

  11. First irradiation test results of the ALICE SAMPA ASIC

    CERN Document Server

    Mahmood, Sohail Musa; Winje, Fredrik Lindseth; Velure, Arild

    2018-01-01

    With the continuous scaling of the CMOS technology, the CMOS circuits are considered to be more tolerant to Single event Latchup (SEL) effects due to the reduction in the supply voltages. This paper reports the results from SEL testing performed on the first two prototypes for the new readout ASIC (SAMPA). During RUN 3/RUN 4 at the Large Hadron Collider (LHC), the SAMPA chip will be used for the upgrade of read-out front end electronics of the ALICE (A Large Ion Collider Experiment) Time Projection Chamber (TPC) and Muon Chambers (MCH). The first prototype MPW1 and the second prototype V2 of the SAMPA chip were delivered in 2015 and 2016, respectively. The results are summarized from two different proton beam irradiation campaigns, conducted for SAMPA MPW1 and V2 prototypes at The Svedberg Laboratory (TSL) in Uppsala, and the Center of Advanced Radiation Technology (KVI) in Groningen, respectively.

  12. Plutonium immobilization program - Cold pour Phase 1 test results

    International Nuclear Information System (INIS)

    Hamilton, L.

    2000-01-01

    The Plutonium Immobilization Project will disposition excess weapons grade plutonium. It uses the can-in-canister approach that involves placing plutonium-ceramic pucks in sealed cans that are then placed into Defense Waste Processing Facility canisters. These canisters are subsequently filled with high-level radioactive waste glass. This process puts the plutonium in a stable form and makes it unattractive for reuse. A cold (non-radioactive) glass pour program was performed to develop and verify the baseline design for the canister and internal hardware. This paper describes the Phase 1 scoping test results

  13. Test Beam Results of Geometry Optimized Hybrid Pixel Detectors

    CERN Document Server

    Becks, K H; Grah, C; Mättig, P; Rohe, T

    2006-01-01

    The Multi-Chip-Module-Deposited (MCM-D) technique has been used to build hybrid pixel detector assemblies. This paper summarises the results of an analysis of data obtained in a test beam campaign at CERN. Here, single chip hybrids made of ATLAS pixel prototype read-out electronics and special sensor tiles were used. They were prepared by the Fraunhofer Institut fuer Zuverlaessigkeit und Mikrointegration, IZM, Berlin, Germany. The sensors feature an optimized sensor geometry called equal sized bricked. This design enhances the spatial resolution for double hits in the long direction of the sensor cells.

  14. Plutonium Immobilization Program - Cold pour Phase 1 test results

    International Nuclear Information System (INIS)

    Hamilton, L.

    2000-01-01

    The Plutonium Immobilization Project will disposition excess weapons grade plutonium. It uses the can-in-canister approach that involves placing plutonium-ceramic pucks in sealed cans that are then placed into Defense Waste Processing Facility canisters. These canisters are subsequently filled with high-level radioactive waste glass. This process puts the plutonium in a stable form and makes it unattractive for reuse. A cold (non-radioactive) glass pour program was performed to develop and verify the baseline design for the canister and internal hardware. This paper describes the Phase 1 scoping test results

  15. Towards General Evaluation of Intelligent Systems: Lessons Learned from Reproducing AIQ Test Results

    Science.gov (United States)

    Vadinský, Ondřej

    2018-03-01

    This paper attempts to replicate the results of evaluating several artificial agents using the Algorithmic Intelligence Quotient test originally reported by Legg and Veness. Three experiments were conducted: One using default settings, one in which the action space was varied and one in which the observation space was varied. While the performance of freq, Q0, Qλ, and HLQλ corresponded well with the original results, the resulting values differed, when using MC-AIXI. Varying the observation space seems to have no qualitative impact on the results as reported, while (contrary to the original results) varying the action space seems to have some impact. An analysis of the impact of modifying parameters of MC-AIXI on its performance in the default settings was carried out with the help of data mining techniques used to identifying highly performing configurations. Overall, the Algorithmic Intelligence Quotient test seems to be reliable, however as a general artificial intelligence evaluation method it has several limits. The test is dependent on the chosen reference machine and also sensitive to changes to its settings. It brings out some differences among agents, however, since they are limited in size, the test setting may not yet be sufficiently complex. A demanding parameter sweep is needed to thoroughly evaluate configurable agents that, together with the test format, further highlights computational requirements of an agent. These and other issues are discussed in the paper along with proposals suggesting how to alleviate them. An implementation of some of the proposals is also demonstrated.

  16. Using computerized provider order entry to enforce documentation of tests with pending results at hospital discharge.

    Science.gov (United States)

    Cadwallader, J; Asirwa, C; Li, X; Kesterson, J; Tierney, W M; Were, M C

    2012-01-01

    Small numbers of tests with pending results are documented in hospital discharge summaries leading to breakdown in communication and medical errors due to inadequate followup. Evaluate effect of using a computerized provider order entry (CPOE) system to enforce documentation of tests with pending results into hospital discharge summaries. We assessed the percent of all tests with pending results and those with actionable results that were documented before (n = 182 discharges) and after (n = 203 discharges) implementing the CPOE-enforcement tool. We also surveyed providers (n = 52) about the enforcement functionality. Documentation of all tests with pending results improved from 12% (87/701 tests) before to 22% (178/812 tests) (p = 0.02) after implementation. Documentation of tests with eventual actionable results increased from 0% (0/24) to 50% (14/28)(ppending results into discharge summaries significantly increased documentation rates, especially of actionable tests. However, gaps in documentation still exist.

  17. LEDA RF distribution system design and component test results

    International Nuclear Information System (INIS)

    Roybal, W.T.; Rees, D.E.; Borchert, H.L.; McCarthy, M.; Toole, L.

    1998-01-01

    The 350 MHz and 700 MHz RF distribution systems for the Low Energy Demonstration Accelerator (LEDA) have been designed and are currently being installed at Los Alamos National Laboratory. Since 350 MHz is a familiar frequency used at other accelerator facilities, most of the major high-power components were available. The 700 MHz, 1.0 MW, CW RF delivery system designed for LEDA is a new development. Therefore, high-power circulators, waterloads, phase shifters, switches, and harmonic filters had to be designed and built for this applications. The final Accelerator Production of Tritium (APT) RF distribution systems design will be based on much of the same technology as the LEDA systems and will have many of the RF components tested for LEDA incorporated into the design. Low power and high-power tests performed on various components of these LEDA systems and their results are presented here

  18. Drop Test Results of CRDM under Seismic Loads

    International Nuclear Information System (INIS)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Kim, Gyeong-Ho; Sun, Jong-Oh; Huh, Hyung

    2016-01-01

    This paper describes the test results to demonstrate the drop performance of CRDM under seismic loads. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the drop performance under seismic loads such as operating basis earthquake (OBE) and safe shutdown earthquake (SSE). Especially, the CAR drop times are important data for the safety analysis. confirm the drop performance under seismic loads. The delay of drop time at Rig no. 2 due to seismic loads is greater than that at Rig no. 3. The total pure drop times under seismic loads are estimated as 1.169 and 1.855, respectively

  19. PWR accident management realated tests: some Bethsy results

    International Nuclear Information System (INIS)

    Clement, P.; Chataing, T.; Deruaz, R.

    1993-01-01

    The BETHSY integral test facility which is a scaled down model of a 3 loop FRAMATOME PWR and is currently operated at the Nuclear Center of Grenoble, forms an important part of the French strategy for PWR Accident Management. In this paper the features of both the facility and the experimental program are presented. Two accident transients: a total loss of feedwater and a 2'' cold leg break in case of High Pressure Safety Injection System failure, involving either Event Oriented - or State Oriented-Emergency Operating Procedures (EO-EOP or SO-EOP) are described and the system response analyzed. CATHARE calculation results are also presented which illustrate the ability of this code to adequately predict the key phenomena of these transients. (authors). 13 figs., 11 refs., 2 tabs

  20. Drop Test Results of CRDM under Seismic Loads

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Kim, Gyeong-Ho; Sun, Jong-Oh; Huh, Hyung [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    This paper describes the test results to demonstrate the drop performance of CRDM under seismic loads. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the drop performance under seismic loads such as operating basis earthquake (OBE) and safe shutdown earthquake (SSE). Especially, the CAR drop times are important data for the safety analysis. confirm the drop performance under seismic loads. The delay of drop time at Rig no. 2 due to seismic loads is greater than that at Rig no. 3. The total pure drop times under seismic loads are estimated as 1.169 and 1.855, respectively.

  1. Foster Wheeler Solar Development Corporation modular industrial solar retrofit qualification test results

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, C.P.; Dudley, V.E.; Lewandoski, A.A.

    1986-10-01

    Under the Department of Energy's Modular Industrial Solar Retrofit project, industrial process steam systems incorporating line-focus solar thermal collectors were designed and hardware was installed and tested. This report describes the test results for the system designed by Foster Wheeler Solar Development Corporation. The test series included function and safety tests to determine that the system operated as specified, an unattended operations test to demonstrate automatic operation, performance tests to provide a database for predicting system performance, and life cycle tests to evaluate component and maintenance requirements. Component-level modifications to improve system performance and reliability were also evaluated.

  2. Foster Wheeler Solar Development Corporation Modular Industrial Solar Retrofit qualification test results

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, C.P.; Dudley, V.E.; Lewandowski, A.A.

    1987-04-01

    Under the Department of Energy's Modular Industrial Solar Retrofit project, industrial process steam systems incorporating line-focus solar thermal collectors were designed and hardware was installed and tested. This report describes the test results for the system designed by Foster Wheeler Solar Development Corporation. The test series included function and safety tests to determine that the system operated as specified, an unattended operations test to demonstrate automatic operation, performance tests to provide a database for predicting system performance, and life cycle tests to evaluate component and maintenance requirements. Component-level modifications to improve system performance and reliability were also evaluated.

  3. Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

    International Nuclear Information System (INIS)

    Chiara, P.; Morelli, A.

    2010-01-01

    The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

  4. Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

    Science.gov (United States)

    Chiara, P.; Morelli, A.

    2010-05-01

    The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements. Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken. This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

  5. Beam test results of the irradiated Silicon Drift Detector for ALICE

    OpenAIRE

    Kushpil, S.; Crescio, E.; Giubellino, P.; Idzik, M.; Kolozhvari, A.; Kushpil, V.; Martinez, M. I.; Mazza, G.; Mazzoni, A.; Meddi, F.; Nouais, D.; Petracek, V.; Piemonte, C.; Rashevsky, A.; Riccati, L.

    2005-01-01

    The Silicon Drift Detectors will equip two of the six cylindrical layers of high precision position sensitive detectors in the ITS of the ALICE experiment at LHC. In this paper we report the beam test results of a SDD irradiated with 1 GeV electrons. The aim of this test was to verify the radiation tolerance of the device under an electron fluence equivalent to twice particle fluence expected during 10 years of ALICE operation.

  6. The passive seismic aftershock Monitoring system: testing program and preliminary results

    International Nuclear Information System (INIS)

    Mokhtari, M.

    2005-01-01

    The paper is dedicated to testing program (phase of the passive seismic aftershock monitoring system with RefTek equipment (Refraction Technology, Inc., USA) for On-Site Inspection purposes that was carried out near Vienna International Centre in 2000. Equipment and applied software are described. Testing results were analyzed; in particular, least needs in maintenance personnel during operation. Development perspectives of passive seismic aftershock monitoring system for On-Site Inspection have been discussed. (author)

  7. Preliminary test results and CFD analysis for Moderator Circulation Test (MCT)

    International Nuclear Information System (INIS)

    Kim, Hyoung Tae

    2015-01-01

    Highlights: • Korea Atomic Energy Research Institute (KAERI) installed the Moderator Circulation Test (MCT) facility. • Velocity profiles for iso-thermal conditions are measured by the Particle Image Velocimetry (PIV). • The PIV measurement results can capture the same flow pattern as that expected in the CANDU6 calandria tank under a momentum dominant flow condition. • More experimental works for the iso-thermal conditions as well as the heating conditions will be performed. • The CFX model will be validated against the PIV measurement data in the future. - Abstract: The moderator flow circulation patterns in CANDU6 reactor are complicated slow flows that significantly vary from buoyancy dominated to inertia dominated patterns. Accurate predictions of flow patterns are essential for accurate calculation of moderator temperature distributions and the related moderator subcooling. The code and its analytical models have therefore to be validated against experiments representative of reactor conditions. Korea Atomic Energy Research Institute (KAERI) installed the Moderator Circulation Test (MCT) facility to simulate the 3 dimensional moderator circulation phenomena in the calandria of CANDU6 reactor and develop the optical measurement system using the Particle Image Velocimetry (PIV). From the present work it is shown that the PIV measurement results can capture the same flow pattern as that expected in the CANDU6 calandria tank under a momentum dominant flow condition, where the inlet jets penetrate the top of the tank and produce a downward flow through the center of the tube columns toward the outlet nozzle, and the flow fields are in symmetric distributions. The measurements of the downward velocities are performed at different locations. The velocity is shown to be axially uniform. The velocity is rapidly decreased as the measurement location is far from the center of the tank, since the downward flow is dominant along the center of the tube columns

  8. NOx results from two combustors tested on medium BTU coal gas

    Science.gov (United States)

    Sherlock, T. P.; Carl, D. E.; Vermes, G.; Schwab, J.; Notardonato, J. J.

    1982-01-01

    The results of tests of two combustor configurations using coal gas from a 25 ton/day fluidized bed coal gasifier are reported. The trials were run with a ceramic-lined, staged rich/lean burner and an integral, all metal multiannular swirl burner (MASB) using a range of temperatures and pressures representative of industrial turbine inlet conditions. A lean mixture was examined at 104, 197, and 254 Btu/Scf, yielding NO(x) emissions of 5, 20, and 70 ppmv, respectively. The MASB was employed only with a gas rated at 220-270 Btu/Scf, producing 80 ppmv NO(x) at rated engine conditions. The results are concluded to be transferrable to current machines. Further tests on the effects of gas composition, the scaling of combustors to utility size, and the development of improved wall cooling techniques and variable geometry are indicated.

  9. Analysis of Factors Influencing Measurement Accuracy of Al Alloy Tensile Test Results

    Science.gov (United States)

    Podgornik, Bojan; Žužek, Borut; Sedlaček, Marko; Kevorkijan, Varužan; Hostej, Boris

    2016-02-01

    In order to properly use materials in design, a complete understanding of and information on their mechanical properties, such as yield and ultimate tensile strength must be obtained. Furthermore, as the design of automotive parts is constantly pushed toward higher limits, excessive measuring uncertainty can lead to unexpected premature failure of the component, thus requiring reliable determination of material properties with low uncertainty. The aim of the present work was to evaluate the effect of different metrology factors, including the number of tested samples, specimens machining and surface quality, specimens input diameter, type of testing and human error on the tensile test results and measurement uncertainty when performed on 2xxx series Al alloy. Results show that the most significant contribution to measurement uncertainty comes from the number of samples tested, which can even exceed 1 %. Furthermore, moving from experimental laboratory conditions to very intense industrial environment further amplifies measurement uncertainty, where even if using automated systems human error cannot be neglected.

  10. Avoidance test with Eisenia fetida as indicator for the habitat function of soils. Results of a laboratory comparison test

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K. [Fraunhofer Inst. for Molecular Biology and Applied Ecology, Schmallenberg (Germany); Achazi, R.; Warnecke, D. [Free Univ. of Berlin, Inst. for Biology, Berlin (Germany); Roembke, J. [ECT Oekotoxikologie GmbH, Floersheim (Germany)

    2003-07-01

    Intention, Goal, Scope, Background. The habitat function of soils is often assessed using the reproduction test with Eisenia fetida. As this test is rather labour-intensive, an alternative is needed which is less cost-intensive in terms of duration and workload, but gives reasonable results. The avoidance test with E. fetida is a suitable screening test meeting these criteria. However, before a novel test system can be generally recommended it has to be ensured that comparable results are acquired from different laboratories on the basis of the respective test guideline. Objective. The avoidance test with E. fetida was performed as laboratory comparison test. The results were compared with those of the earthworm acute and reproduction tests carried out with the same soils. Methods. The three tests were performed by three laboratories using eight contaminated soils and three control soils. The contaminated soils were mixed with the control soils to obtain different concentrations of the contamination. (orig.)

  11. Test results for fuel cell operation on anaerobic digester gas

    Science.gov (United States)

    Spiegel, R. J.; Preston, J. L.

    EPA, in conjunction with ONSI, embarked on a project to define, design, test, and assess a fuel cell energy recovery system for application at anaerobic digester waste water (sewage) treatment plants. Anaerobic digester gas (ADG) is produced at these plants during the process of treating sewage anaerobically to reduce solids. ADG is primarily comprised of methane (57-66%), carbon dioxide (33-39%), nitrogen (1-10%), and a small amount of oxygen (sulfur-bearing compounds (principally hydrogen sulfide) and halogen compounds (chlorides). The project has addressed two major issues: development of a cleanup system to remove fuel cell contaminants from the gas and testing/assessing of a modified ONSI PC25 C fuel cell power plant operating on the cleaned, but dilute, ADG. Results to date demonstrate that the ADG fuel cell power plant can, depending on the energy content of the gas, produce electrical output levels close to full power (200 kW) with measured air emissions comparable to those obtained by a natural gas fuel cell. The cleanup system results show that the hydrogen sulfide levels are reduced to below 10 ppbv and halides to approximately 30 ppbv.

  12. Preliminary results of a test of a longitudinal phase-space monitor

    International Nuclear Information System (INIS)

    Kikutani, Eiji; Funakoshi, Yoshihiro; Kawamoto, Takashi; Mimashi, Toshihiro

    1994-01-01

    A prototype of a longitudinal phase-space monitor has been developed in TRISTAN Main Ring at KEK. The principle of the monitor and its basic components are explained. Also a result of a preliminary beam test is given. (author)

  13. Re-evaluation of the 1995 Hanford Large Scale Drum Fire Test Results

    International Nuclear Information System (INIS)

    Yang, J M

    2007-01-01

    A large-scale drum performance test was conducted at the Hanford Site in June 1995, in which over one hundred (100) 55-gal drums in each of two storage configurations were subjected to severe fuel pool fires. The two storage configurations in the test were pallet storage and rack storage. The description and results of the large-scale drum test at the Hanford Site were reported in WHC-SD-WM-TRP-246, ''Solid Waste Drum Array Fire Performance,'' Rev. 0, 1995. This was one of the main references used to develop the analytical methodology to predict drum failures in WHC-SD-SQA-ANAL-501, 'Fire Protection Guide for Waste Drum Storage Array,'' September 1996. Three drum failure modes were observed from the test reported in WHC-SD-WM-TRP-246. They consisted of seal failure, lid warping, and catastrophic lid ejection. There was no discernible failure criterion that distinguished one failure mode from another. Hence, all three failure modes were treated equally for the purpose of determining the number of failed drums. General observations from the results of the test are as follows: (lg b ullet) Trash expulsion was negligible. (lg b ullet) Flame impingement was identified as the main cause for failure. (lg b ullet) The range of drum temperatures at failure was 600 C to 800 C. This is above the yield strength temperature for steel, approximately 540 C (1,000 F). (lg b ullet) The critical heat flux required for failure is above 45 kW/m 2 . (lg b ullet) Fire propagation from one drum to the next was not observed. The statistical evaluation of the test results using, for example, the student's t-distribution, will demonstrate that the failure criteria for TRU waste drums currently employed at nuclear facilities are very conservative relative to the large-scale test results. Hence, the safety analysis utilizing the general criteria described in the five bullets above will lead to a technically robust and defensible product that bounds the potential consequences from postulated

  14. Assessment of the system code DRUFAN/ATHLET using results of LOBI tests

    International Nuclear Information System (INIS)

    Burwell, J.M.; Kirmse, R.E.; Kyncl, M.; Malhotra, P.K.

    1989-09-01

    Four post-test analyses have been performed by GRS within the Shared Cost Action Programme (SCAP) sponsored by the Commission of the European Communities (contract 3015-86-07 EL ISP D) and by the Bundesminister fuer Forschung und Technologie of the Federal Republic of Germany (Research project RS 739). The four tests were mutually selected by the contractors (CEA, GRS, IKE, Univ. Pisa) of activity No. 3 and by the project organizer. Some of the tests were selected to be analyzed by more than one participant in order to allow comparison between analytical results obtained with different codes or obtained by different code-users. DRUFAN/ATHLET verification analyses were performed by IKE too. The four tests selected for the GRS activity are: - A2-77A (Natural Circulation Test), Analysis with ATHLET - A1-76 (Steam Generator Performance Test), Analysis with DRUFAN - BL-01 (Intermediate Leak), Analysis with ATHLET - A2-81 (Small Leak), Analysis with ATHLET. This final report contains the results of the four post test analysis including the comparison between measured and calculated quantities and the description of the applied codes, the selected model of the LOBI facility and the conclusions drawn for the improvement of the codes models

  15. Data on test results of vessel cooling system of high temperature engineering test reactor

    International Nuclear Information System (INIS)

    Saikusa, Akio; Nakagawa, Shigeaki; Fujimoto, Nozomu; Tachibana, Yukio; Iyoku, Tatsuo

    2003-02-01

    High Temperature Engineering Test Reactor (HTTR) is the first graphite-moderated helium gas cooled reactor in Japan. The rise-to-power test of the HTTR started on September 28, 1999 and thermal power of the HTTR reached its full power of 30 MW on December 7, 2001. Vessel Cooling System (VCS) of the HTTR is the first Reactor Cavity Cooling System (RCCS) applied for High Temperature Gas Cooled Reactors. The VCS cools the core indirectly through the reactor pressure vessel to keep core integrity during the loss of core flow accidents such as depressurization accident. Minimum heat removal of the VCS to satisfy its safety requirement is 0.3MW at 30 MW power operation. Through the performance test of the VCS in the rise-to-power test of the HTTR, it was confirmed that the VCS heat removal at 30 MW power operation was higher than 0.3 MW. This paper shows outline of the VCS and test results on the VCS performance. (author)

  16. Aerodynamic Flight-Test Results for the Adaptive Compliant Trailing Edge

    Science.gov (United States)

    Cumming, Stephen B.; Smith, Mark S.; Ali, Aliyah N.; Bui, Trong T.; Ellsworth, Joel C.; Garcia, Christian A.

    2016-01-01

    The aerodynamic effects of compliant flaps installed onto a modified Gulfstream III airplane were investigated. Analyses were performed prior to flight to predict the aerodynamic effects of the flap installation. Flight tests were conducted to gather both structural and aerodynamic data. The airplane was instrumented to collect vehicle aerodynamic data and wing pressure data. A leading-edge stagnation detection system was also installed. The data from these flights were analyzed and compared with predictions. The predictive tools compared well with flight data for small flap deflections, but differences between predictions and flight estimates were greater at larger deflections. This paper describes the methods used to examine the aerodynamics data from the flight tests and provides a discussion of the flight-test results in the areas of vehicle aerodynamics, wing sectional pressure coefficient profiles, and air data.

  17. Results of patch testing in 10 patients with peristomal dermatitis.

    Science.gov (United States)

    Landis, Megan N; Keeling, James H; Yiannias, James A; Richardson, Donna M; Nordberg Linehan, Diane L; Davis, Mark D P

    2012-09-01

    Peristomal dermatitis is a common problem in patients with ostomies that is a source of considerable morbidity. Irritant contact dermatitis is most common, but allergic contact dermatitis can also occur. Because of the lack of published reports on patch testing for this indication, we undertook a retrospective study of patch testing results in patients with suspected peristomal allergic contact dermatitis. We sought to describe our patch testing experience with patients referred with peristomal dermatitis. This was a retrospective review of medical records of patients with ostomies and peristomal dermatitis who underwent patch testing in the Mayo Clinic Departments of Dermatology in Jacksonville, FL; Rochester, MN; and Scottsdale, AZ, during a 10-year period (2000-2010). Ten patients with peristomal dermatitis were referred for patch testing (6 in Minnesota, 2 in Florida, and 2 in Arizona). Patients were patch tested to the materials used in their stoma devices, to the standard series, and in some cases to supplemental series. All 10 had at least one allergic patch test reaction, most commonly to stoma paste (3 of 10 patients). Retrospective nature of study via chart review is a limitation. Patch testing is a useful tool for identification of allergens in patients with peristomal dermatitis. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Expose : procedure and results of the joint experiment verification tests

    Science.gov (United States)

    Panitz, C.; Rettberg, P.; Horneck, G.; Rabbow, E.; Baglioni, P.

    The International Space Station will carry the EXPOSE facility accommodated at the universal workplace URM-D located outside the Russian Service Module. The launch will be affected in 2005 and it is planned to stay in space for 1.5 years. The tray like structure will accomodate 2 chemical and 6 biological PI-experiments or experiment systems of the ROSE (Response of Organisms to Space Environment) consortium. EXPOSE will support long-term in situ studies of microbes in artificial meteorites, as well as of microbial communities from special ecological niches, such as endolithic and evaporitic ecosystems. The either vented or sealed experiment pockets will be covered by an optical filter system to control intensity and spectral range of solar UV irradiation. Control of sun exposure will be achieved by the use of individual shutters. To test the compatibility of the different biological systems and their adaptation to the opportunities and constraints of space conditions a profound ground support program has been developed. The procedure and first results of this joint Experiment Verification Tests (EVT) will be presented. The results will be essential for the success of the EXPOSE mission and have been done in parallel with the development and construction of the final hardware design of the facility. The results of the mission will contribute to the understanding of the organic chemistry processes in space, the biological adaptation strategies to extreme conditions, e.g. on early Earth and Mars, and the distribution of life beyond its planet of origin.

  19. Nonlinear Analysis and Preliminary Testing Results of a Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.; Wu, Hsi-Yung T.

    2015-01-01

    A large test article was recently designed, analyzed, fabricated, and successfully tested up to the representative design ultimate loads to demonstrate that stiffened composite panels with through-the-thickness reinforcement are a viable option for the next generation large transport category aircraft, including non-conventional configurations such as the hybrid wing body. This paper focuses on finite element analysis and test data correlation of the hybrid wing body center section test article under mechanical, pressure and combined load conditions. Good agreement between predictive nonlinear finite element analysis and test data is found. Results indicate that a geometrically nonlinear analysis is needed to accurately capture the behavior of the non-circular pressurized and highly-stressed structure when the design approach permits local buckling.

  20. Decisional Outcomes of Maternal Disclosure of BRCA1/2 Genetic Test Results to Children

    Science.gov (United States)

    Tercyak, Kenneth P.; Mays, Darren; DeMarco, Tiffani A.; Peshkin, Beth N.; Valdimarsdottir, Heiddis B.; Schneider, Katherine A.; Garber, Judy E.; Patenaude, Andrea Farkas

    2013-01-01

    Background Although BRCA1/2 genetic testing is discouraged in minors, mothers may disclose their own results to their children. Factors affecting patients’ disclosure decisions and patient outcomes of disclosure are largely unknown. Methods Mothers (N = 221) of children ages 8-21 enrolled in this prospective study of family communication about cancer genetic testing. Patients underwent BRCA1/2 genetic counseling and testing, and completed standardized behavioral assessments prior to and 1-month following receipt of their results. Results Most patients (62.4%) disclosed BRCA1/2 test results to their child. Patients were more likely to disclose if they received negative or uninformative vs. positive results (OR = 3.11; 95% CI = 1.11 - 8.71; P = .03), their child was ≥ 13 years of age vs. younger (OR = 5.43; 95% CI = 2.18 - 13.53; P Post-decision satisfaction about disclosure was lowest among nondisclosing patients (P information is perceived as beneficial. Satisfaction with disclosure decision-making remains lowest among nondisclosing and conflicted patients. Family communication decision support adjuncts to genetic counseling are needed to help ameliorate these effects. Impact This study describes the prevalence of family communication about maternal BRCA1/2 genetic testing with minor children, and decisions and outcomes of disclosure. PMID:23825307

  1. Critical Joints in Large Composite Primary Aircraft Structures. Volume 3: Ancillary Test Results

    Science.gov (United States)

    Bunin, Bruce L.; Sagui, R. L.

    1985-01-01

    A program was conducted to develop the technology for critical structural joints for composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of a comprehensive ancillary test program are summarized, consisting of single-bolt composite joint specimens tested in a variety of configurations. These tests were conducted to characterize the strength and load deflection properties that are required for multirow joint analysis. The composite material was Toray 300 fiber and Ciba-Geigy 914 resin, in the form of 0.005 and 0.01 inch thick unidirectional tape. Tests were conducted in single and double shear for loaded and unloaded hole configurations under both tensile and compressive loading. Two different layup patterns were examined. All tests were conducted at room temperature. In addition, the results of NASA Standard Toughness Test (NASA RP 1092) are reported, which were conducted for several material systems.

  2. Orimulsion{reg_sign} new generation: New commercial tests results

    Energy Technology Data Exchange (ETDEWEB)

    Marruffo, F.; Sarmiento, W.

    2000-07-01

    The new generation of Orimulsion{reg_sign} has been tested since September 1998 and was released to the market on January 1999 by PDVSA-Bitor. Main results from plants will be treated in detail within this paper. Boiler performance has been considerably improved by fuel switching. Operation changes could be summarized as follows: (1) Better furnace wall heat absorption; (2) Lower backend temperature; and (3) Lower sootblowing frequency. In Fuel Oil designed units, the new Orimulsion{reg_sign} firing current performance is similar to Fuel Oil, which indicates a similarity in combustion characteristics between these two fuels. This permits the switching to Orimulsion{reg_sign} in these units with only very minor modification. When compared to its predecessor, the new generation of Orimulsion{reg_sign} has proven to be a better product also from the environmental point of view. Due to its completely new designed surfactant package and its new architecture, the following results have consistently been shown: (1) Lower SO{sub 3} emissions; (2) Less CO production; and (3) Lower particulate levels.

  3. Test results of the 18 kA EDIPO HTS current leads

    International Nuclear Information System (INIS)

    Wesche, Rainer; Bagnasco, Maurizio; Bruzzone, Pierluigi; Felder, Roland; Guetg, Marc; Holenstein, Manuel; Jenni, Markus; March, Stephen; Roth, Felix; Vogel, Martin

    2011-01-01

    For the new test facility EDIPO (European DIPOle), to be hosted by CRPP, two 18 kA HTS current leads were manufactured and successfully tested. The HTS module, made of AgMgAu/Bi-2223 tapes, is cooled only by heat conduction to the cold end, while the copper part is cooled by forced flow helium gas. The current leads were tested at low voltage up to the maximum current of 18 kA. The helium mass flow rates required for stable operation at various currents were determined. In addition to the steady state operation, the transient behavior in the case of a loss of flow was studied experimentally. The test results provide an estimate of the operational limits of the EDIPO HTS current leads.

  4. Test results of the 18 kA EDIPO HTS current leads

    Energy Technology Data Exchange (ETDEWEB)

    Wesche, Rainer, E-mail: rainer.wesche@psi.ch [Ecole Polytechnique Federale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association Euratom - Confederation Suisse, 5232 Villigen PSI (Switzerland); Bagnasco, Maurizio; Bruzzone, Pierluigi; Felder, Roland; Guetg, Marc; Holenstein, Manuel; Jenni, Markus; March, Stephen; Roth, Felix; Vogel, Martin [Ecole Polytechnique Federale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association Euratom - Confederation Suisse, 5232 Villigen PSI (Switzerland)

    2011-10-15

    For the new test facility EDIPO (European DIPOle), to be hosted by CRPP, two 18 kA HTS current leads were manufactured and successfully tested. The HTS module, made of AgMgAu/Bi-2223 tapes, is cooled only by heat conduction to the cold end, while the copper part is cooled by forced flow helium gas. The current leads were tested at low voltage up to the maximum current of 18 kA. The helium mass flow rates required for stable operation at various currents were determined. In addition to the steady state operation, the transient behavior in the case of a loss of flow was studied experimentally. The test results provide an estimate of the operational limits of the EDIPO HTS current leads.

  5. Preliminary results of the round-robin testing of F82H

    Energy Technology Data Exchange (ETDEWEB)

    Shiba, K.; Yamanouchi, N.; Tohyama, A.

    1996-10-01

    Preliminary results of metallurgical, physical and mechanical properties of low activation ferritic steel F82H (IEA heat) were obtained in the round-robin test in Japan. The properties of IEA heat F82H were almost the same as the original F82H.

  6. Tokamak Fusion Test Reactor D-T results

    International Nuclear Information System (INIS)

    Meade, D.M.

    1995-01-01

    Temperatures, densities and confinement of deuterium plasmas confined in tokamaks have been achieved within the last decade that are approaching those required for a D-T reactor. As a result, the unique phenomena present in a D-T reactor plasma (D-T plasma confinement, α confinement, α heating and possible α-driven instabilities) can now be studied in the laboratory. Recent experiments on the Tokamak Fusion Test Reactor (TFTR) have been the first magnetic fusion experiments to study plasmas with reactor fuel concentrations of tritium. The injection of about 20MW of tritium and 14MW of deuterium neutral beams into the TFTR produced a plasma with a T-to-D density ratio of about 1 and yielding a maximum fusion power of about 9.2MW. The fusion power density in the core of the plasma was about 1.8MWm -3 , approximating that expected in a D-T fusion reactor. A TFTR plasma with a T-to-D density ratio of about 1 was found to have about 20% higher energy confinement time than a comparable D plasma, indicating a confinement scaling with average ion mass A of τ E ∝A 0.6 . The core ion temperature increased from 30 to 37keV owing to a 35% improvement of ion thermal conductivity. Using the electron thermal conductivity from a comparable deuterium plasma, about 50% of the electron temperature increase from 9 to 10.6keV can be attributed to electron heating by the α particles. The approximately 5% loss of α particles, as observed on detectors near the bottom edge of the plasma, was consistent with classical first orbit loss without anomalous effects. Initial measurements have been made of the confined high energy α particles and the resultant α ash density. At fusion power levels of 7.5MW, fluctuations at the toroidal Alfven eigen-mode frequency were observed by the fluctuation diagnostics. However, no additional α loss due to the fluctuations was observed. (orig.)

  7. Results from Field Testing the RIMFAX GPR on Svalbard.

    Science.gov (United States)

    Hamran, S. E.; Amundsen, H. E. F.; Berger, T.; Carter, L. M.; Dypvik, H.; Ghent, R. R.; Kohler, J.; Mellon, M. T.; Nunes, D. C.; Paige, D. A.; Plettemeier, D.; Russell, P.

    2017-12-01

    The Radar Imager for Mars' Subsurface Experiment - RIMFAX is a Ground Penetrating Radar being developed for NASÁs MARS 2020 rover mission. The principal goals of the RIMFAX investigation are to image subsurface structures, provide context for sample sites, derive information regarding subsurface composition, and search for ice or brines. In meeting these goals, RIMFAX will provide a view of the stratigraphic section and a window into the geological and environmental history of Mars. To verify the design an Engineering Model (EM) of the radar was tested in the field in the spring 2017. Different sounding modes on the EM were tested in different types of subsurface geology on Svalbard. Deep soundings were performed on polythermal glaciers down to a couple of hundred meters. Shallow soundings were used to map a ground water table in the firn area of a glacier. A combination of deep and shallow soundings was used to image buried ice under a sedimentary layer of a couple of meters. Subsurface sedimentary layers were imaged down to more than 20 meters in sand stone permafrost. This presentation will give an overview of the RIMFAX investigation, describe the development of the radar system, and show results from field tests of the radar.

  8. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Science.gov (United States)

    Wesolowski, Laura G; Mackellar, Duncan A; Ethridge, Steven F; Zhu, Julia H; Owen, S Michele; Sullivan, Patrick S

    2008-02-06

    Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (ptest [adjusted OR 2.6, 95% CI (1.3, 4.9)]. Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.

  9. Pre- and Post-Test Results of KEEP Class 2: 1973-74. Technical Report #40.

    Science.gov (United States)

    Fox, Candy

    This report presents the pre-and posttest results for the kindergarten year of the Kamehameha Early Education Program (KEEP) Class 2, 1973-1974. Results are presented for the Wechsler Preschool and Primary Scale of Intelligence (WPPSI), the Metropolitan Readiness Test (MRT), and the Standard English Repetition Test (SERT). Comparisons are made…

  10. Calibration of straight TXRF analysis - results of an European Round Robin test

    International Nuclear Information System (INIS)

    Rink, I.; Wortelboer, R.; Gendt, S. de; Horn, M.; Steiner, J.; Neumann, C.; Knoth, J.; Schwenke, H.; Dobler, M.; Erdmann, V.; Rostam-Khani, P.; Kolbesen, B.O.; Metz, S.; Pahlke, S.; Fabry, L.; Gonchond, J.P.; Weiss, C.; Comin, F.

    2000-01-01

    Calibration of spot measurements pose in general less problems than calibration of straight TXRF measurements as several Round Robin tests show. This is at least matter of discussion for those TXRF users who apply a droplet standard for straight TXRF measurements at the angle of incident where particle and film-type contamination show the same fluorescence intensity - the so-called iso-angle. In order to gain more insight in the differences between several TXRF-equipment types and calibration methods we started an European Round Robin test in 1998 in which twelve firms participated using twenty different TXRF-tools, one RBS- and one Synchrotron-TXRF equipment. In contrast to earlier global Round Robin tests e.g. in 1996 (ISO/TC201/WG2) direct comparison of measurements of the same wafers is possible, because the same wafers were sent to several participants and additional reference measurements were performed at Philips as well. Wafer preparation has been performed by spin-coating of Ni (5 concentrations) and by dipping in Fe-spiked SCI-solution (1 blank, 2 spiking concentrations). From this eight sets were formed containing eight wafers with varying Ni-and Fe-concentrations. All wafers were firstly measured at Philips as reference and then sent to certain participant-groups. The results of this first measurement show that the sets were almost comparable to each other with a standard deviation of < 15 % for the variants Ni-3, Ni-4, Ni-5 and Fe-2, with exception of few single concentrations of some sets. After normalization it is possible to compare all results of these variants with one reference value. The results can be divided in three groups with similar results and one extreme outlier: group 1: RBS-results and those results based on correction with Fit-program from GKSS, calibration with spin-coated wafers (RBS, Radio tracer) and results of one XSA 8000 and of one Rigaku 3750; group 2: Results of all Atomika TXRF 8030, three Atomika TXRF 8010, one TREX630S

  11. Boraflex test results and evaluation

    International Nuclear Information System (INIS)

    Lindquist, K.; Kline, D.E.; Haley, T.C.

    1993-02-01

    New data developed, collected, and evaluated to further assess the in-pool performance of the neutron absorber material, Boraflex. The data are from new EPRI test programs, utility surveillance programs, and blackness testing at a number of plants. This new data provides a basis for quantifying the gap phenomenon in full length panels of Boraflex in spent fuel racks; the maximum anticipated gap size, frequency of gap occurrence, and axial distribution of gaps. Methods have been developed to assess the reactivity effects of gaps and Boraflex shrinkage. The analyses presented demonstrates that the reactivity effect of gaps is very small, not much larger than the statistical variations inherent in the calculational method. The data and analyses presented serve to close the issue of gap formation and shrinkage in panels of Boraflex and the effect of such gaps and shrinkage on the reactivity of the fuel/rack configuration. Ongoing EPRI programs to assess the long term performance of Boraflex in spent fuel storage racks are described

  12. The Dornier 328 Acoustic Test Cell (ATC) for interior noise tests and selected test results

    Science.gov (United States)

    Hackstein, H. Josef; Borchers, Ingo U.; Renger, Klaus; Vogt, Konrad

    1992-01-01

    To perform acoustic studies for achieving low noise levels for the Dornier 328, an acoustic test cell (ATC) of the Dornier 328 has been built. The ATC consists of a fuselage section, a realistic fuselage suspension system, and three exterior noise simulation rings. A complex digital 60 channel computer/amplifier noise generation system as well as multichannel digital data acquisition and evaluation system have been used. The noise control tests started with vibration measurements for supporting acoustic data interpretation. In addition, experiments have been carried out on dynamic vibration absorbers, the most important passive noise reduction measure for low frequency propeller noise. The design and arrangement of the current ATC are presented. Furthermore, exterior noise simulation as well as data acquisition are explained. The most promising results show noise reduction due to synchrophasing and dynamic vibration absorbers.

  13. Results and implications of the EBR-II inherent safety demonstration tests

    International Nuclear Information System (INIS)

    Planchon, H.P.; Golden, G.H.; Sackett, J.I.; Mohr, D.; Chang, L.K.; Feldman, E.E.; Betten, P.R.

    1987-01-01

    On April 3, 1986 two milestone tests were conducted in Experimental Breeder Reactor-2 (EBR-II). The first test was a loss of flow without scram and the second was a loss of heat sink without scram. Both tests were initiated from 100% power and in both tests the reactor was shut down by natural processes, principally thermal expansion, without automatic scram, operator intervention or the help of special in-core devices. The temperature transients during the tests were mild, as predicted, and there was no damage to the core or reactor plant structures. In a general sense, therefore, the tests plus supporting analysis demonstrated the feasibility of inherent passive shutdown for undercooling accidents in metal-fueled LMRs. The results provide a technical basis for future experiments in EBR-II to demonstrate inherent safety for overpower accidents and provide data for validation of computer codes used for design and safety analysis of inherently safe reactor plants

  14. RESULTS OF THE FIRST MI-171A2 FLYING LABORATORY TEST PHASE

    OpenAIRE

    V. A. Ivchin; K. Y. Samsonov

    2014-01-01

    The present publication describes the results of the first stage of the flying laboratory (Mi-171 helicopter) flight tests performed at Mil Moscow Helicopter Plant, JSC facilities. Main rotor components with blades made of polymer composite materials and X-type tail rotor were tested on the Mi-171 № 14987, flying laboratory, under Mi-171A Helicopter Retrofit Program.

  15. ANALYSIS AND QUANTITATIVE ASSESSMENT FOR RESULTS OF EDUCATIONAL PROGRAMS APPLICATION BY MEANS OF DIAGNOSTIC TESTS

    Directory of Open Access Journals (Sweden)

    E. L. Kon

    2015-07-01

    Full Text Available Subject of Research.The problem actuality for creation, control and estimation of results for competence-oriented educational programs is formulated and proved. Competences elements and components, assembled in modules, course units and parts of educational program, are defined as objects of control. Specific tasks of proficiency examination for competences and their components are stated; subject matter of the paper is formulated. Methods of Research. Some adapted statements and methods of technical science are offered to be applied for control tasks solution, decoding and estimation of education results. The approach to quantitative estimation of testing results with the use of additive integrated differential criterion of estimation is offered. Main Results. Statements, defining conditions of certain and uncertain (indeterminacy decision-making about proficiency examination for elements of discipline components controlled by test according to test realization results, are formulated and proved. Probabilistic characteristicsof both decision-making variants are estimated. Variants of determinate and fuzzy logic mathematic methods application for decreasing decision-making indeterminancy are offered; further research direction is selected for development of methods and algorithms for results decoding of diagnostic tests set realization. Practical Relevance. It is shown, that proposed approach to quantitative estimation of testing results will give the possibility to automate the procedure of formation and analysis for education results, specified in the competence format.

  16. Stirling cryocooler test results and design model verification

    International Nuclear Information System (INIS)

    Shimko, M.A.; Stacy, W.D.; McCormick, J.A.

    1990-01-01

    This paper reports on progress in developing a long-life Stirling cycle cryocooler for space borne applications. It presents the results from tests on a preliminary breadboard version of the cryocooler used to demonstrate the feasibility of the technology and to validate the regenerator design code used in its development. This machine achieved a cold-end temperature of 65 K while carrying a 1/2 Watt cooling load. The basic machine is a double-acting, flexure-bearing, split Stirling design with linear electromagnetic drives for the expander and compressors. Flat metal diaphragms replace pistons for both sweeping and sealing the machine working volumes. In addition, the double-acting expander couples to a laminar-channel counterflow recuperative heat exchanger for regeneration. A PC compatible design code was developed for this design approach that calculates regenerator loss including heat transfer irreversibilities, pressure drop, and axial conduction in the regenerator walls

  17. How to correct the ambient temperature influence on the thermal response test results

    International Nuclear Information System (INIS)

    Borinaga-Treviño, Roque; Norambuena-Contreras, Jose; Castro-Fresno, Daniel

    2015-01-01

    Due to global warming and to the increasing energy demand, it is necessary to improve energy efficiency on buildings. In this context, Ground-Coupled Heat Pumps (GCHP) have proved to be the most efficient heating and cooling system. The main parameters to define a ground heat exchanger are obtained via an in situ test called Thermal Response Test (TRT). However, ambient air influence on this test is remarkable due to the exposition of the testing machine, and even the ground undisturbed temperature varies with the ambient temperature oscillations. Therefore, despite the fact that the influence of ambient conditions on the TRT results is an important topic in order to define a ground heat exchanger, there is yet a limited literature on new theoretical methods to correct the ambient temperature influence on the predicted ground thermal conductivity measured via TRT. This paper presents a new methodology to analyse and mitigate the influence of the ambient conditions on the TRT results, with the main advantage that it is not necessary to know its physical origin previously. The method is focused on reducing the mean fluid temperature oscillations caused by the ambient temperature, by analysing the influence of the chosen time interval to fit the data to the infinite line source theory formulae that finally predicts the ground thermal conductivity. With these purpose, results of two different TRTs were analysed, each of them with a different equipment and ambient exposition. Results using the proposed method showed that thermal conductivity oscillations were reduced in both tests. For the first test, the uncertainty associated to the chosen time interval for the estimation was diminished by 33%, reducing significantly its predicted value and thus avoiding the future installation possible under-designing. However, because of the equipment insulation improvements and the smoother ambient temperature variations, the method obtained similar results for the predicted

  18. Safety test results of lithium-thionyl chloride wound-type cells

    Science.gov (United States)

    Vallin, D.; Broussely, M.

    1989-05-01

    Increase in the use of spirally-wound, lithium-thionyl chloride cells is currently limited because of unsafe incidents which have been reported during the early stage of development of this product. Today, it is believed that these cells are safe over a wide range of operating conditions if properly designed. The paper describes the external and internal SAFT design of Li-SOCl2LSH series cells, as well as the results of safety tests.

  19. Hot-Fire Test Results of Liquid Oxygen/RP-2 Multi-Element Oxidizer-Rich Preburners

    Science.gov (United States)

    Protz, C. S.; Garcia, C. P.; Casiano, M. J.; Parton, J. A.; Hulka, J. R.

    2016-01-01

    As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center was contracted to assemble and hot-fire test a multi-element integrated test article demonstrating combustion characteristics of an oxygen/hydrocarbon propellant oxidizer-rich staged-combustion engine thrust chamber. Such a test article simulates flow through the main injectors of oxygen/kerosene oxidizer-rich staged combustion engines such as the Russian RD-180 or NK-33 engines, or future U.S.-built engine systems such as the Aerojet-Rocketdyne AR-1 engine or the Hydrocarbon Boost program demonstration engine. To supply the oxidizer-rich combustion products to the main injector of the integrated test article, existing subscale preburner injectors from a previous NASA-funded oxidizer-rich staged combustion engine development program were utilized. For the integrated test article, existing and newly designed and fabricated inter-connecting hot gas duct hardware were used to supply the oxidizer-rich combustion products to the oxidizer circuit of the main injector of the thrust chamber. However, before one of the preburners was used in the integrated test article, it was first hot-fire tested at length to prove it could provide the hot exhaust gas mean temperature, thermal uniformity and combustion stability necessary to perform in the integrated test article experiment. This paper presents results from hot-fire testing of several preburner injectors in a representative combustion chamber with a sonic throat. Hydraulic, combustion performance, exhaust gas thermal uniformity, and combustion stability data are presented. Results from combustion stability modeling of these test results are described in a companion paper at this JANNAF conference, while hot-fire test results of the preburner injector in the integrated test article are described in another companion paper.

  20. Friction and wear in liquid-metal systems: comparability problems of test results obtained from different test facilities

    International Nuclear Information System (INIS)

    Wild, E.; Mack, K.J.

    1976-01-01

    Operational induced relative movements take place between contacting components in the core region of sodium cooled reactors. To ensure reliable long term functioning of such friction loaded components, materials are needed with good sliding properties and high wear resistance. Therefore, tribological properties of material combinations in liquid metal have been investigated experimentally for many years at various research establishments. However, despite identical boundary conditions, the comparison of results published does not yield a satisfactory agreement. The cause must be seen in the individual design and concept of the test sections used. This discrepancy was investigated. The results show that the elasticity, mass movement, and relative motion characteristic to the system prove to be the most important criteria influencing the test results

  1. Results of the quality assurance testing program for radiopharmaceuticals 1995

    Energy Technology Data Exchange (ETDEWEB)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( {sup 99m}Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [{sup 201}Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs.

  2. Results of the quality assurance testing program for radiopharmaceuticals 1995

    International Nuclear Information System (INIS)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( 99m Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [ 201 Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs

  3. Test results of the AGS Booster low frequency RF system

    International Nuclear Information System (INIS)

    Sanders, R.T.; Cameron, P.; Damm, R.; Dunbar, A.; Goldman, M.; Kasha, D.; McNerney, A.; Meth, M.; Ratti, A.; Spitz, R.

    1993-01-01

    The Band II RF system was originally built to support the Booster operations during the acceleration of heavy ions. Designed to sweep from 0.6 to 2.5 MHz, it was build and successfully tested over a much broader range reaching 4 MHz. Voltages up to more than 20 kV were reached over the design frequency range. The system consists of two stations, each of which is made of one single gap cavity directly driven by a grounded cathode push pull power amplifier. The low Q high permeability ferrites needed in the coaxial cavity in order to reach the lower end of the band make tuning extremely easy. Both systems were thoroughly tested both at single frequencies and on a sweep and are now installed in the ring, ready for operations. Static measurements showed no high-loss effects. The Band 11 system has been fully described in a previous paper; presented here are the results of the ''bench'' tests that lead to important performance improvements

  4. CIEMAT interlaboratories comparison of the results obtained in the proficiency test run by IAEA

    International Nuclear Information System (INIS)

    Gasco, C.; Anton, M. P.; Alvarez, A.; Navarro, N.; Meral, J.; Gonzalez, A.; Higueras Lafaja, E.

    2000-01-01

    This report contains the results obtained by two different laboratories from CIEMAT after participating in the Proficiency Test organised by IAEA (International Atomic Energy Agency) in 1999. This test involves the analysis of fly ashes containing natural radionuclides and different amounts of added transuranics. The extraction techniques, counting methods and results obtained are detailed. This type of test are used for the labs to achieve their accreditation and check the reliability of the procedures routinely employed. (Author) 4 refs

  5. In situ vitrification: Test results for a contaminated soil-melting process

    International Nuclear Information System (INIS)

    Buelt, J.L.; Timmerman, C.L.; Westsik, J.H. Jr.

    1989-10-01

    In situ vitrification (ISV) is being developed at Pacific Northwest Laboratory for the Department of Energy to stabilize soils and sludges that are contaminated with radioactive and hazardous chemical wastes. ISV is a process that immobilizes contaminated soil in place by converting it to a durable glass and crystalline product similar to obsidian and basalt. In June 1987, a large-scale test of the process was completed at a transuranic-contaminated soil site. The test constituted the first full-scale demonstration of ISV at an actual site. This paper summarizes the results of that test and describes the potential adaptation of the process to radioactive and hazardous chemical waste-contaminated soils. 15 refs., 9 figs., 3 tabs

  6. Stirling Convertor Performance Mapping Test Results for Future Radioisotope Power Systems

    Science.gov (United States)

    Qiu, Songgang; Peterson, Allen A.; Faultersack, Franklyn D.; Redinger, Darin L.; Augenblick, John E.

    2004-02-01

    Long-life radioisotope-fueled generators based on free-piston Stirling convertors are an energy-conversion solution for future space applications. The high efficiency of Stirling machines makes them more attractive than the thermoelectric generators currently used in space. Stirling Technology Company (STC) has been performance-testing its Stirling generators to provide data for potential system integration contractors. This paper describes the most recent test results from the STC RemoteGen™ 55 W-class Stirling generators (RG-55). Comparisons are made between the new data and previous Stirling thermodynamic simulation models. Performance-mapping tests are presented including variations in: internal charge pressure, cold end temperature, hot end temperature, alternator temperature, input power, and variation of control voltage.

  7. Compact Multipurpose Mobile Laser Scanning System — Initial Tests and Results

    Directory of Open Access Journals (Sweden)

    Craig Glennie

    2013-01-01

    Full Text Available We describe a prototype compact mobile laser scanning system that may be operated from a backpack or unmanned aerial vehicle. The system is small, self-contained, relatively inexpensive, and easy to deploy. A description of system components is presented, along with the initial calibration of the multi-sensor platform. The first field tests of the system, both in backpack mode and mounted on a helium balloon for real-world applications are presented. For both field tests, the acquired kinematic LiDAR data are compared with highly accurate static terrestrial laser scanning point clouds. These initial results show that the vertical accuracy of the point cloud for the prototype system is approximately 4 cm (1σ in balloon mode, and 3 cm (1σ in backpack mode while horizontal accuracy was approximately 17 cm (1σ for the balloon tests. Results from selected study areas on the Sacramento River Delta and San Andreas Fault in California demonstrate system performance, deployment agility and flexibility, and potential for operational production of high density and highly accurate point cloud data. Cost and production rate trade-offs place this system in the niche between existing airborne and tripod mounted LiDAR systems.

  8. Pipe damping: experimental results from laboratory tests in the seismic frequency range

    International Nuclear Information System (INIS)

    Ware, A.G.; Arendts, J.G.

    1986-06-01

    The Idaho National Engineering Laboratory (INEL) has been conducting a research program to assist the United States Nuclear Regulatory Commission (USNRC) in determining best-estimate damping values for the seismic analysis of nuclear piping systems. As part of this program, a 5-in. piping system was tested by the INEL, and data from USNRC/EPRI piping vibration tests at the ANCO Engineers facility were evaluated. These systems were subjected to various types of excitation methods and magnitudes, the support configurations were varied, and the effects of pipe insulation and internal pressure were investigated on the INEL system. The INEL has used several different methods to reduce the data to determine the damping in both these piping systems under the various test conditions. It was concluded that at representative seismic excitation levels, pressure was not a contributing factor, but the supports, insulation, and magnitude of response all were major influences contributing to damping. These tests are part of the ongoing program to determine how various parameters and data reduction methods affect piping system damping. The evaluation of all relevant test results, including these two series, will potentially lead to revised damping guidelines for the seismic analysis of nuclear plants, making them safer, less costly, and easier to inspect and maintain. The test results as well as accompanying evaluations and recommendations are presented in this report. 27 refs., 72 figs., 13 tabs

  9. RESULTS OF THE FIRST MI-171A2 FLYING LABORATORY TEST PHASE

    Directory of Open Access Journals (Sweden)

    V. A. Ivchin

    2014-01-01

    Full Text Available The present publication describes the results of the first stage of the flying laboratory (Mi-171 helicopter flight tests performed at Mil Moscow Helicopter Plant, JSC facilities. Main rotor components with blades made of polymer composite materials and X-type tail rotor were tested on the Mi-171 № 14987, flying laboratory, under Mi-171A Helicopter Retrofit Program.

  10. Retrospective Review of Treponema pallidum PCR and Serology Results: Are Both Tests Necessary?

    Science.gov (United States)

    Brischetto, Anna; Gassiep, Ian; Whiley, David; Norton, Robert

    2018-05-01

    There has been a resurgence of syphilis diagnoses in Australia. We investigated whether our Treponema pallidum PCR test provides any additional diagnostic information over syphilis serology (chemiluminescence immunoassay [CMIA], Treponema pallidum particle agglutination [TPPA] assay, and the rapid plasma reagin [RPR] flocculation test). A retrospective audit of all T. pallidum PCR requests that came through our laboratory from January 2010 to June 2017 was conducted; data collected included age, gender, site of swab, and results from T. pallidum PCR, syphilis serology, and herpes simplex virus 1 (HSV-1) and HSV-2 PCRs. A total of 441 T. pallidum PCR tests were performed; on average, 3 T. pallidum PCRs per month were requested in 2011, and this rate increased to 17.2 requests per month in 2017. A total of 323 patients had both T. pallidum PCR and syphilis serology performed, with 67% of swabs taken from the genitals. T. pallidum PCR gave positive results for 61/323 (19%) patients; of these 61 patients, 59 (97%) also had positive syphilis serology results ( T. pallidum PCR sensitivity, 68%; specificity, 99%; positive predictive value, 97%; negative predictive value, 89%). Syphilis serology was positive for 91/323 patients (28%); of these 91 patients, 61 (66%) were also T. pallidum PCR positive (syphilis serology sensitivity, 97%; specificity, 88%; positive predictive value, 60%; negative predictive value, 99%). The Cohen's kappa value was 0.74, indicating substantial agreement between the two tests. Our results show that most patients with positive T. pallidum PCR results also had positive syphilis serology. Therefore, T. pallidum PCR adds little clinical value over serology for the diagnosis of syphilis in certain clinical settings. Copyright © 2018 American Society for Microbiology.

  11. [Reliability for detection of developmental problems using the semaphore from the Child Development Evaluation test: Is a yellow result different from a red result?

    Science.gov (United States)

    Rizzoli-Córdoba, Antonio; Ortega-Ríosvelasco, Fernando; Villasís-Keever, Miguel Ángel; Pizarro-Castellanos, Mariel; Buenrostro-Márquez, Guillermo; Aceves-Villagrán, Daniel; O'Shea-Cuevas, Gabriel; Muñoz-Hernández, Onofre

    The Child Development Evaluation (CDE) is a screening tool designed and validated in Mexico for detecting developmental problems. The result is expressed through a semaphore. In the CDE test, both yellow and red results are considered positive, although a different intervention is proposed for each. The aim of this work was to evaluate the reliability of the CDE test to discriminate between children with yellow/red result based on the developmental domain quotient (DDQ) obtained through the Battelle Development Inventory, 2nd edition (in Spanish) (BDI-2). The information was obtained for the study from the validation. Children with a normal (green) result in the CDE were excluded. Two different cut-off points of the DDQ were used (BDI-2): social: 20.1% vs. 28.9%; and adaptive: 6.9% vs. 20.4%. The semaphore result yellow/red allows identifying different magnitudes of delay in developmental domains or subdomains, supporting the recommendation of different interventions for each one. Copyright © 2014 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  12. Safety test results of lithium-thionyl chloride wound-type cells

    Energy Technology Data Exchange (ETDEWEB)

    Vallin, D.; Broussely, M. (British Columbia Univ., Vancouver (Canada))

    1989-05-01

    Increase in the use of spirally-wound, lithium-thionyl chloride cells is currently limited because of unsafe incidents which have been reported during the early stage of development of this product. Today, it is believed that these cells are safe over a wide range of operating conditions if properly designed. The paper describes the external and internal SAFT design of Li-SOCl2LSH series cells, as well as the results of safety tests. 6 refs.

  13. Results of Shipboard Approval Tests of Ballast Water Treatment Systems in Freshwater

    Science.gov (United States)

    2014-11-01

    with the protist and microbial results, the results of these tests were unaffected by p3SFS flow meter/control malfunctions and can be considered...organisms. > 60 % average PS and < 20 % average RPD. Percentage of Protist Samples Analyzed by a Second Taxonomist: 0 %* Cannot be...determined*; a second (QA) count was not conducted Percentage of protist samples analyzed by a second taxonomist: 20 % (0/2 intake samples

  14. Correlating Dynamometer Testing to In-Use Fleet Results of Plug-In Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    John G. Smart; Sera White; Michael Duoba

    2009-05-01

    Standard dynamometer test procedures are currently being developed to determine fuel and electrical energy consumption of plug-in hybrid vehicles (PHEV). To define a repeatable test procedure, assumptions were made about how PHEVs will be driven and charged. This study evaluates these assumptions by comparing results of PHEV dynamometer testing following proposed procedures to actual performance of PHEVs operating in the US Department of Energy’s (DOE) North American PHEV Demonstration fleet. Results show PHEVs in the fleet exhibit a wide range of energy consumption, which is not demonstrated in dynamometer testing. Sources of variation in performance are identified and examined.

  15. The comparative analysis of model and prototype test results of Bulb turbine

    International Nuclear Information System (INIS)

    Benisek, M; Bozic, I; Ignjatovic, B

    2010-01-01

    This paper presents the problem of the hydropower plant oblique water inflow and its influence on the turbines operation. Oblique water inflow on the low head hydropower plant with bulb turbines influences turbine characteristics. The characteristics change occurs due to swirl incidence in the turbine inlet which spreads to the guide vanes inlet. Downstream, the flow conditions change is caused in the turbine runner in relation to the flow conditions without swirl inflow. Special attention is paid to the phenomenon of swirl flow incidence in the turbine conduit. With the aim of presenting and analyzing the oblique water inflow consequences on the hydropower plant operation, the existing turbine model tests results, performed in the laboratories, and the in situ prototype testing results have been used.

  16. Amphetamines and cannabinoids testing in hair: Evaluation of results from a two-year period.

    Science.gov (United States)

    Burgueño, María José; Alonso, Amaya; Sánchez, Sergio

    2016-08-01

    This paper presents an overview of a set of amphetamines and cannabinoids tests performed on head hair samples from the Medico-Legal sector at the Madrid Department of the Spanish National Institute of Toxicology and Forensic Sciences during the years 2013 and 2014. The hair samples were tested for five stimulant phenylalkylamine derivatives -amphetamine (AP), methamphetamine (MA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-amphetamine (MDA), and 3,4-methylenedioxy-N-ethylamphetamine (MDEA)- and/or two cannabinoids-Δ(9)-tetrahydrocannabinol (THC) and cannabinol (CBN)- by gas chromatography equipped with mass spectrometry detection in selected-ion monitoring mode, applying a method accredited to ISO/IEC 17025 standards. The test results were interpreted according to the confirmation cut-offs proposed by the Society of Hair Testing (SoHT) to identify chronic drug use. The ratios of positive results were studied in relation to gender, age, hair colour, dyeing and length of the tested samples to assess the independence from these variables or the association with them. Low, medium and high ranges of concentration were also estimated for each drug. 21.94% of the 2954 hair samples tested for phenylalkylamine derivatives were positive for one or more substances. 16.38% of the samples were positive for AP, 12.09% for MDMA and only 0.44% for MA. 6.60% of the tested samples were positive for AP/MDMA combination. A total of 3178 samples were tested for cannabinoids, resulting in 53.40% positive for THC and CBN. Simultaneous tests for phenylalkylamine derivatives and cannabinoids were performed in 2931 of the samples; 14.94% of them were positive for THC, CBN, and one or more amphetamines. According to the results from the statistical analysis, the use of THC and MDMA vary with age and gender among the Medico-Legal sector in an extended area of Spain, while the use of AP appears to be independent of these variables. On the other hand, the results of THC in

  17. Overview of the PBF test results

    International Nuclear Information System (INIS)

    Zeile, H.J.

    1980-01-01

    The Thermal Fuels Behavior Program (TFBP) of EG and G Idaho conducts fuel behavior research in the Power Burst Facility (PBF) at INEL and at the Halden Reactor in Norway. The fuels behavior research in the PBF is directed toward providing a detailed understanding of the response of light water reactor (LWR) nuclear fuel assemblies to off-normal and hypothesized accident conditions. Single fuel rods and clusters of highly instrumented fuel rods are installed within a central test space of the PBF core for testing. The core can be operated in various modes to provide test conditions typical of accidents and off-normal conditions that may be experienced in a pressurized water reactor or a boiling water reactor

  18. Preliminary test results for post irradiation examination on the HTTR fuel

    International Nuclear Information System (INIS)

    Ueta, Shohei; Umeda, Masayuki; Sawa, Kazuhiro; Sozawa, Shizuo; Shimizu, Michio; Ishigaki, Yoshinobu; Obata, Hiroyuki

    2007-01-01

    The future post-irradiation program for the first-loading fuel of the HTTR is scheduled using the HTTR fuel handling facilities and the Hot Laboratory in the Japan Materials Testing Reactor (JMTR) to confirm its irradiation resistance and to obtain data on its irradiation characteristics in the core. This report describes the preliminary test results and the future plan for a post-irradiation examination for the HTTR fuel. In the preliminary test, fuel compacts made with the same SiC-coated fuel particle as the first loading fuel were used. In the preliminary test, dimension, weight, fuel failure fraction, and burnup were measured, and X-ray radiograph, SEM, and EPMA observations were carried out. Finally, it was confirmed that the first-loading fuel of the HTTR showed good quality under an irradiation condition. The future plan for the post-irradiation tests was described to confirm its irradiation performance and to obtain data on its irradiation characteristics in the HTTR core. (author)

  19. SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT

    International Nuclear Information System (INIS)

    Rusk, B; Fontenot, J

    2016-01-01

    Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modes using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.

  20. SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Rusk, B; Fontenot, J [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States)

    2016-06-15

    Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modes using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.

  1. Initial Burn Pan (JMTF) Testing Results

    Science.gov (United States)

    2016-03-01

    burn pan and one located high on the Ex-USS Shadwell. There were also a number of GoPro cameras (3-4) that were positioned to observe specific...locations around the test area. A remote control drone equipped with a GoPro camera was also used to video the third test. All recorded video and still

  2. RESULTS OF IMMUNOLOGICAL TESTING OF NEW GENERATION IN CHILDREN UNDER MASSIVE VACCINATION AGAINST TUBERCULOSIS

    Directory of Open Access Journals (Sweden)

    A. A. Starshinova

    2017-01-01

    Full Text Available Development of new methods of immune diagnostics of tuberculous infection and their introduction into tuberculosis control practice have changed approaches to diagnostics of tuberculosis in Russia. Along with world recognized IGRA-tests the test with tuberculous recombinant allergen (TRA developed by Russian researchers is also widely used. High diagnostic value of each of the methods is proved by multiple national and international trials however there is no research comparing results of these methods in the diagnostics of tuberculous infection in children, including those with concurrent conditions. During the study data of testing in 654 children in the age from 0 to 14 years old with positive sensitivity to tuberculin as per Mantoux test with 2 TU were analyzed. All patients had modern immunological tests done: TRA and IGRA-tests (QuantifeRON® Gold ELISA (QFT and T-SPOT.TB. The study confirmed the low value of Mantoux test with 2 TU as a method of early tuberculosis detection in children; it detected underdiagnosis (10-50% and overdiagnosis (78% of latent tuberculous infection in the children with different sensitivity level as per data of Mantoux test with 2 TU. Comparing the results of TRA and IGRA tests it is possible to state that they are compatible for 76-81% of cases. The group of children was detected who had allergic and endocrine disorders (obesity, for whom IGRA tests were recommended to exclude chances of false-positive results of TRA tests

  3. Should Australia Ban the Use of Genetic Test Results in Life Insurance?

    Science.gov (United States)

    Tiller, Jane; Otlowski, Margaret; Lacaze, Paul

    2017-01-01

    Under current Australian regulation, life insurance companies can require applicants to disclose all genetic test results, including results from research or direct-to-consumer tests. Life insurers can then use this genetic information in underwriting and policy decisions for mutually rated products, including life, permanent disability, and total income protection insurance. Over the past decade, many countries have implemented moratoria or legislative bans on the use of genetic information by life insurers. The Australian government, by contrast, has not reviewed regulation since 2005 when it failed to ensure implementation of recommendations made by the Australian Law Reform Commission. In that time, the Australian life insurance industry has been left to self-regulate its use of genetic information. As a result, insurance fears in Australia now are leading to deterred uptake of genetic testing by at-risk individuals and deterred participation in medical research, both of which have been documented. As the potential for genomic medicine grows, public trust and engagement are critical for successful implementation. Concerns around life insurance may become a barrier to the development of genomic health care, research, and public health initiatives in Australia, and the issue should be publicly addressed. We argue a moratorium on the use of genetic information by life insurers should be enacted while appropriate longer term policy is determined and implemented.

  4. Should Australia Ban the Use of Genetic Test Results in Life Insurance?

    Directory of Open Access Journals (Sweden)

    Jane Tiller

    2017-12-01

    Full Text Available Under current Australian regulation, life insurance companies can require applicants to disclose all genetic test results, including results from research or direct-to-consumer tests. Life insurers can then use this genetic information in underwriting and policy decisions for mutually rated products, including life, permanent disability, and total income protection insurance. Over the past decade, many countries have implemented moratoria or legislative bans on the use of genetic information by life insurers. The Australian government, by contrast, has not reviewed regulation since 2005 when it failed to ensure implementation of recommendations made by the Australian Law Reform Commission. In that time, the Australian life insurance industry has been left to self-regulate its use of genetic information. As a result, insurance fears in Australia now are leading to deterred uptake of genetic testing by at-risk individuals and deterred participation in medical research, both of which have been documented. As the potential for genomic medicine grows, public trust and engagement are critical for successful implementation. Concerns around life insurance may become a barrier to the development of genomic health care, research, and public health initiatives in Australia, and the issue should be publicly addressed. We argue a moratorium on the use of genetic information by life insurers should be enacted while appropriate longer term policy is determined and implemented.

  5. When parents disclose BRCA1/2 test results: their communication and perceptions of offspring response.

    Science.gov (United States)

    Bradbury, Angela R; Patrick-Miller, Linda; Egleston, Brian L; Olopade, Olufunmilayo I; Daly, Mary B; Moore, Cynthia W; Sands, Colleen B; Schmidheiser, Helen; Kondamudi, Preethi K; Feigon, Maia; Ibe, Comfort N; Daugherty, Christopher K

    2012-07-01

    BRCA1/2 testing is not recommended for children, as risk reduction measures and screening are not generally recommended before 25 years old (YO). Little is known about the prevalence and predictors of parent communication to offspring and how offspring respond to this communication. Semi-structured interviews were conducted with parents who had BRCA1/2 testing and at least 1 child parents completed interviews (61% response rate), reporting on 505 offspring. Twenty-nine percent of parents were BRCA1/2 mutation carriers. Three hundred thirty-four (66%) offspring learned of their parent's test result. Older offspring age (P ≤ .01), offspring gender (female, P = .05), parents' negative test result (P = .03), and parents' education (high school only, P = .02) were associated with communication to offspring. The most frequently reported initial offspring responses were neutral (41%) or relief (28%). Thirteen percent of offspring were reported to experience concern or distress (11%) in response to parental communication of their test results. Distress was more frequently perceived among offspring learning of their parent's BRCA1/2 positive or variant of uncertain significance result. Many parents communicate their BRCA1/2 test results to young offspring. Parents' perceptions of offspring responses appear to vary by offspring age and parent test result. A better understanding of how young offspring respond to information about hereditary risk for adult cancer could provide opportunities to optimize adaptive psychosocial responses to risk information and performance of health behaviors, in adolescence and throughout an at-risk life span. Copyright © 2012 American Cancer Society.

  6. Solar energy characteristics and some photovoltaic testing results in Jeddah

    Energy Technology Data Exchange (ETDEWEB)

    Mosalam Shaltout, M A

    1986-01-01

    The data for global radiation were analysed to investigate the correlation with climatological factors. Solar cell module testing under Jeddah climatic conditions was initiated in 1984-1985. The goal of this work was to study the performance and reliability of a commercially-available module in outdoor conditions in order to obtain information on solar cell system design, and to observe the influence of our specific climate conditions on module energy output. The use of results obtained for precise system sizing is discussed.

  7. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Directory of Open Access Journals (Sweden)

    Laura G Wesolowski

    Full Text Available BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB, immunofluorescent assay (IFA or approved nucleic acid amplification test (NAAT. When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result, repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6% were reactive: of these, 2417 (93% had positive WB/IFA, 172 (7% had negative or indeterminate WB/IFA. Of 89/172 (52% persons with a repeat confirmatory test: 17 (19% were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81% were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative (p<0.001 and having an initial oral fluid WB (vs. serum (p<0.001. Persons who had male-female sex (vs. male-male sex were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for

  8. Patch testing for allergic contact dermatitis: Three years retrospective results in Tekirdağ

    Directory of Open Access Journals (Sweden)

    Gamze Erfan

    2015-06-01

    Full Text Available Background and Design: Allergic contact dermatitis is a delayed type hypersensitivity reaction to allergens in individuals who were sensitized with same allergens before. The causative allergens may change in time as well as vary among geographical and population based differences. Materials and Methods: The characteristics of 169 patients-107 (63.3% male, 62 (36.7% female, who patch tested between 2011- 2014 with allergic contact dermatitis diagnosis and test results were retrospectively analysed. Results: The mean age of all patients who had the most frequent occupation as service sector/house wife (26.6% were 41.06 years and the mean disease duration of all patients was 19.5 months. The most frequent localization of disease was hands (n: 105,%73 and %50.3 of patients had positivity with at least one allergen. The most frequent seven allergens with positivity were nickel sulfate (n: 50, %29.6, cobalt chloride (n: 23, %13.6, potassium dichromate (n: 22, %13, sesquiterpene lactone mix (n: 18, %10.7, thiuram (n: 10, %5.9, clioquinol mix (n: 10, %5.9 and 4-tert-butilfenol formaldehyde resin (n: 10, %5.9, respectively. On the other hand in all patients there were no positivity with N-Isopropyl-N-phenyl-4-phenylenediamine, epoxy resin, balsam of peru, formaldehyde, quaternium-15, primin, tixocortol-21-pivalate, fragrance mix-2. Conclusion: In comparison of this study which first reports patch test results of patients in Tekirdağ-a city in Trakya region and other studies that report patch test results of different regions of our country; the mean age of patients of present study were older and there were similar results for occupations and localization of disease in between eastern region and present study. We believe that further studies are needed to specify allergen characteristics of Trakya region using multicenter studies, which include other cities as well.

  9. Accuracy of self-reports of fecal occult blood tests and test results among individuals in the carpentry trade.

    Science.gov (United States)

    Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F

    2003-11-01

    Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.

  10. Results of the 2015 Relationship Testing Workshop of the English Speaking Working Group

    DEFF Research Database (Denmark)

    Friis, Susanne Lunøe; Hallenberg, Charlotte; Simonsen, Bo Thisted

    2015-01-01

    Annually, members of the English Speaking Working Group of the International Society for Forensic Genetics are invited to participate in a Relationship Testing Workshop. In 2015, 64 laboratories participated. Here, we present the results from the 2015 workshop, which included relationship testing...

  11. Estimation of the Altai region population exposure resulting from the nuclear tests at the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Djachenko, V.I.; Gabbasov, M.N.; Laborev, V.M.; Markovtsev, A.S.; Sudakov, V.V.; Volobuyev, N.M.; Zelenov, V.I.; Lagutin, A.A.; Shoikher, J.N.

    1998-01-01

    The historical roots of reconstruction of doses received by populations from nuclear tests date back to the 60''s, when the world faced a problem of growing radioactive contamination by radioactive fallout resulting from atmospheric nuclear tests. Since then, only one aspect of this problem has been properly developed, namely: public-exposure doses resulting from the global radioactive fallout have been estimated. Local fallout, which occurred mainly in the territories of the test sites and regions adjacent to their boundaries, was considered and studied as an internal affair of the states. The first steps in creating the above-mentioned methodological basis were taken in Russia, where, by now, the methodology of dose estimation in regions of local radioactive fallout has been determined and acknowledged nationwide as a standard document (Federal Committee on Sanitay Epidemiological Control of RF, 1994). It was this methodology that was used for calculations and dose estimation of the exposure of the Altai population from the Semipalatinsk Test Site (STS). (orig./GL)

  12. Orion Pad Abort 1 Crew Module Inertia Test Approach and Results

    Science.gov (United States)

    Herrera, Claudia; Harding, Adam

    2010-01-01

    The Flight Loads Laboratory at the Dryden Flight Research Center conducted tests to measure the inertia properties of the Orion Pad Abort 1 (PA-1) Crew Module. These measurements were taken to validate analytical predictions of the inertia properties of the vehicle and assist in reducing uncertainty for derived aero performance results calculated post launch. The first test conducted was to determine the Ixx of the Crew Module. This test approach used a modified torsion pendulum test step up that allowed the suspended Crew Module to rotate about the x axis. The second test used a different approach to measure both the Iyy and Izz properties. This test used a Knife Edge fixture that allowed small rotation of the Crew Module about the y and z axes. Discussions of the techniques and equations used to accomplish each test are presented. Comparisons with the predicted values used for the final flight calculations are made. Problem areas, with explanations and recommendations where available, are addressed. Finally, an evaluation of the value and success of these techniques to measure the moments of inertia of the Crew Module is provided.

  13. Patch test results in patients with allergic contact dermatitis in Yozgat

    Directory of Open Access Journals (Sweden)

    Emine Çölgeçen Özel

    2013-09-01

    Full Text Available Background and Design: Patch testing is valuable in the diagnosis of allergic contact dermatitis (ACD as well as in determining the causative agent and thus is helpful in prevention of the disease and also provides information for the patient Material and Method: Hundred and sixty-eight patients (94 female and 74 male with ACD were patch tested with European standard series. Patch test result were assessed according to suggestion of International Contact Dermatitis Research Group at 48 and 72 hours after initial application. Results: Of the patients, 64.3% were between 16-45 years of age and majority of the lesions (57.1% were localized on the hands. A total of 86 (51.1% patients had one or more positive patch test reactions. The most common allergens were nickel sulfate (20.2% followed by potassium dichromate (8.3%, cobalt chloride (7.1%, fragrance mix (7.1%, paraphenylendiamine base (6%, paraben mix 3.6%, N-isopropyl-N-phenyl-p-phenylenediamine (3.6%, wool alcohols (3.6%, formaldehyde (3.6%, quaternium-15 (3.6%. Positive reactions to nickel sulfate were more common among women, especially those in younger group. Frequency of contact allergy to neomycin sulfate, epoxy resin, 4-tert-butylphenolformaldehyde resin, sesquiterpenelactone mix, primin, 5-chloro-2-methyl-4-isothiazolin-3-1, budesonide, lyral were relatively low (1.2%, while no positive reaction was obtained to clioquinol and methyldibromoglutaronitrile in any case. Conclusion: Since no similar study has been previously performed in our area, this study provides information about contact allergen profile in patients underwent skin patch test with a diagnosis of AKD at Yozgat. The most frequent allergens detected with ASS and frequency rates may vary among different facilities at various cities of Turkey. A standard series for our country may be created after assessment of regional variability by new studies conducted in same time zone.

  14. High Rate User Ka-Band Phased Array Antenna Test Results

    Science.gov (United States)

    Caroglanian, Armen; Perko, Kenneth; Seufert, Steve; Dod, Tom; Warshowsky, Jay; Day, John H. (Technical Monitor)

    2001-01-01

    The High Rate User Phased Array Antenna (HRUPAA) is a Ka-Band planar phased array designed by the Harris Corporation for the NASA Goddard Space Flight Center. The HRUPAA permits a satellite to downlink data either to a ground station or through the Tracking and Data Relay Satellite System (TDRSS). The HRUPAA is scanned electronically by ground station / user satellite command over a 120 degree cone angle. The phased array has the advantage of not imparting attitude disturbances to the user spacecraft. The 288-element transmit-only array has distributed RF amplifiers integrated behind each of the printed patch antenna elements. The array has 33 dBW EIRP and is left-hand circularly polarized. An engineering model of a partially populated array has been developed and delivered to NASA Goddard Space Flight Center. This report deals with the testing of the engineering model at the Goddard Antenna Range near-field and compact range facilities. The antenna specifications are described first, followed by the test plan and test results.

  15. Test results on parabolic dish concentrators for solar thermal power systems

    Science.gov (United States)

    Jaffe, Leonard D.

    1989-01-01

    This paper presents results of development testing of various solar thermal parabolic dish concentrators. The concentrators were mostly designed for the production of electric power using dish-mounted Rankine, Brayton or Stirling cycle engines, intended to be produced at low cost. Measured performance for various dishes included optical efficiencies ranging from 0.32 to 0.86 at a geometric concentration ratio of 500, and from about 0.09 to 0.85 at a geometric concentration ratio of 3000. Some malfunctions were observed. The tests should provide operating information of value in developing concentrators with improved performance and reduced maintenance.

  16. General Atomic reprocessing pilot plant: description and results of initial testing

    International Nuclear Information System (INIS)

    1977-12-01

    In June 1976 General Atomic completed the construction of a reprocessing head-end cold pilot plant. In the year since then, each system within the head end has been used for experiments which have qualified the designs. This report describes the equipment in the plant and summarizes the results of the initial phase of reprocessing testing

  17. Results of SC proton cavity tests (B = 1 and B = 0.65)

    CERN Document Server

    Peauger, F et al

    2013-01-01

    The two superconducting cavities were carefully designed for challenging performance. They were fabricated in industry with intermediate tests and specialized processing in CEA and CNRS. The results are promising, except for a degradation of the field flatness of the low velocity cavity, after electron-beam welding. This might reduce the accelerating gradient. Due to delays in manufacturing, the final performance tests will be carried out in the coming months.

  18. The impact of training process on the stress tests results of women cross country skiing representation.

    OpenAIRE

    Fusková, Dana

    2015-01-01

    Title: The impact of training process on the stress tests results of women cross country skiing representation. Aim: The aim of this thesis is the comparison of the results of stress tests carried out preparatory period before and after the preparation period and whether the results were influenced by the applied training process. Methods: In this thesis was used background research of professional publications, content analyzes of documents and comparison of the results of stress tests and c...

  19. Use of hyperlinks in electronic test result communication: a survey study in general practice

    Directory of Open Access Journals (Sweden)

    Mukai Thomas

    2012-10-01

    Full Text Available Abstract Background Information is essential in healthcare. Recording, handling and sharing healthcare information is important in order to ensure high quality of delivered healthcare. Information and communication technology (ICT may be a valuable tool for handling these challenges. One way of enhancing the exchange of information could be to establish a link between patient-specific and general information sent to the general practitioner (GP. The aim of the present paper is to study GPs' use of a hyperlink inserted into electronic test result communication. Methods We inserted a hyperlink into the electronic test result communication sent to the patients’ GPs who participated in a regional, systematic breast cancer screening program. The hyperlink target was a web-site with information on the breast cancer screening program and breast cancer in general. Different strategies were used to increase the GPs’ use of this hyperlink. The outcome measure was the GPs’ self-reported use of the link. Data were collected by means of a one-page paper-based questionnaire. Results The response rate was 73% (n=242. In total, 108 (45% of the GPs reported to have used the link. In all, 22% (n=53 of the GPs used the web-address from a paper letter and 37% (n=89 used the hyperlink in the electronic test result communication (Δ = 15%[95%confidence  int erval(CI = 8 − 22%P  Conclusions The results suggest that hyperlinks in electronic test result communication could be a feasible strategy for combining and sharing different types of healthcare information.

  20. Trends in Pap test practices and results: An 11-year review of the annual ACHA Pap Test and STI Survey.

    Science.gov (United States)

    Eastman-Mueller, Heather P; Oswalt, Sara B

    2017-10-01

    To conduct a trend analysis of Pap test practices, Pap test results and related women's services and guidelines of college health centers. College health centers who participated in the annual ACHA Pap Test and STI (sexually transmitted infection) Survey years 2004-2014 (n ranged from 127 to 181 depending on year). Descriptive analyses are presented with ANOVAs (Analysis of Variance) and chi-square tests calculated to examine trends over time. The number of Pap tests significantly decreased over time; however, the percentage of normal and HSIL (high-grade squamous intraepithelial lesion) results did not vary. Availability of conventional cytology slides and cryotherapy were significantly associated with year. Over time, college health centers' guidelines related to initiation of Pap testing evolved to consistently conform to national recommendations for cervical screening. The results indicate most college health centers are following the current national guidelines regarding Pap testing for young adult women.

  1. Summary of CPAS EDU Testing Analysis Results

    Science.gov (United States)

    Romero, Leah M.; Bledsoe, Kristin J.; Davidson, John.; Engert, Meagan E.; Fraire, Usbaldo, Jr.; Galaviz, Fernando S.; Galvin, Patrick J.; Ray, Eric S.; Varela, Jose

    2015-01-01

    The Orion program's Capsule Parachute Assembly System (CPAS) project is currently conducting its third generation of testing, the Engineering Development Unit (EDU) series. This series utilizes two test articles, a dart-shaped Parachute Compartment Drop Test Vehicle (PCDTV) and capsule-shaped Parachute Test Vehicle (PTV), both of which include a full size, flight-like parachute system and require a pallet delivery system for aircraft extraction. To date, 15 tests have been completed, including six with PCDTVs and nine with PTVs. Two of the PTV tests included the Forward Bay Cover (FBC) provided by Lockheed Martin. Advancements in modeling techniques applicable to parachute fly-out, vehicle rate of descent, torque, and load train, also occurred during the EDU testing series. An upgrade from a composite to an independent parachute simulation allowed parachute modeling at a higher level of fidelity than during previous generations. The complexity of separating the test vehicles from their pallet delivery systems necessitated the use the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulator for modeling mated vehicle aircraft extraction and separation. This paper gives an overview of each EDU test and summarizes the development of CPAS analysis tools and techniques during EDU testing.

  2. Design and preliminary test results of the quench detection system for IFSMTF

    International Nuclear Information System (INIS)

    Shen, S.S.; Walstrom, P.L.; Wilson, C.T.; Goddard, J.S.

    1985-01-01

    A unique quench detection system was designed for the International Fusion Superconducting Magnet Test Facility (IFSMTF), where a simultaneous test of six large superconducting toroidal field magnets will be carried out. The scheme was based on analog subtraction of self and neighboring pickup winding voltage from the coil voltage to yield a compensated signal proportional to a normal-zone voltage. The compensated signals were input to quench detection modules that give a quench output signal to discharge the coil if the compensated signals exceed preset thresholds for preset time durations. This paper summarizes the design and analysis of the system and presents the experimental results of the simulation tests, two-coil charging-discharging tests, and the normal-zone recovery tests

  3. 49 CFR 40.163 - How does the MRO report drug test results?

    Science.gov (United States)

    2010-10-01

    ... How does the MRO report drug test results? (a) As the MRO, it is your responsibility to report all... copy of that report in a format suitable for inspection and auditing by a DOT representative. (f) You...

  4. Interim results: fines recycle testing using the 4-inch diameter primary graphite burner

    International Nuclear Information System (INIS)

    Palmer, W.B.

    1975-05-01

    The results of twenty-two HTGR primary burner runs in which graphite fines were recycled pneumatically to the 4-inch diameter pilot-plant primary fluidized-bed burner are described. The result of the tests showed that zero fines accumulation can easily be achieved while operating at plant equivalent burn rates. (U.S.)

  5. [Genetic predisposition to breast and ovarian cancer: importance of test results].

    Science.gov (United States)

    Julian-Reynier, Claire

    2011-01-01

    Oncogenetic consultations and predictive BRCA1/2 testing are intertwined processes and the specific impact of these genetic tests if performed alone through direct-to-consumer offers remains unknown. Noteworthy, the expectations of patients vary with their own status, whether they are affected or not by breast cancer at the time genetic testing is performed. The prescription of genetic tests for BCRA mutations has doubled in France between 2003 and 2009. There is a consensus on the fact that genetic results disclosure led to a significant increase in the knowledge and understanding that the patients have of the genetic risk and also changed the medical follow-up of these patients. Evaluating the psychological burden of tests disclosure did not reveal any major distress in patients who are followed by high-quality multidisciplinary teams. Longitudinal cohorts studies have now evaluated the perception and behaviour of these patients, and observed sociodemographic as well as geographic and psychosocial differences both in the acceptation of prophylactic strategies such as surgery, and time to surgery. © 2011 médecine/sciences - Inserm / SRMS.

  6. Correlation Results for a Mass Loaded Vehicle Panel Test Article Finite Element Models and Modal Survey Tests

    Science.gov (United States)

    Maasha, Rumaasha; Towner, Robert L.

    2012-01-01

    High-fidelity Finite Element Models (FEMs) were developed to support a recent test program at Marshall Space Flight Center (MSFC). The FEMs correspond to test articles used for a series of acoustic tests. Modal survey tests were used to validate the FEMs for five acoustic tests (a bare panel and four different mass-loaded panel configurations). An additional modal survey test was performed on the empty test fixture (orthogrid panel mounting fixture, between the reverb and anechoic chambers). Modal survey tests were used to test-validate the dynamic characteristics of FEMs used for acoustic test excitation. Modal survey testing and subsequent model correlation has validated the natural frequencies and mode shapes of the FEMs. The modal survey test results provide a basis for the analysis models used for acoustic loading response test and analysis comparisons

  7. Wind Tunnel and Hover Performance Test Results for Multicopter UAS Vehicles

    Science.gov (United States)

    Russell, Carl R.; Jung, Jaewoo; Willink, Gina; Glasner, Brett

    2016-01-01

    There is currently a lack of published data for the performance of multicopter unmanned aircraft system (UAS) vehicles, such as quadcopters and octocopters, often referred to collectively as drones. With the rapidly increasing popularity of multicopter UAS, there is interest in better characterizing the performance of this type of aircraft. By studying the performance of currently available vehicles, it will be possible to develop models for vehicles at this scale that can accurately predict performance and model trajectories. This paper describes a wind tunnel test that was recently performed in the U.S. Army's 7- by 10-ft Wind Tunnel at NASA Ames Research Center. During this wind tunnel entry, five multicopter UAS vehicles were tested to determine forces and moments as well as electrical power as a function of wind speed, rotor speed, and vehicle attitude. The test is described here in detail, and a selection of the key results from the test is presented.

  8. 76 FR 19952 - Not Applying the Mark of Inspection Pending Certain Test Results

    Science.gov (United States)

    2011-04-11

    ... livestock carcasses subject to FSIS testing for such veterinary drugs as antibiotics, sulfonamides, or... submitted in response to this proposal, as well as background information used by FSIS in developing this..., effective control measures to ensure the product is not used or distributed for sale before the test results...

  9. Comparison of transient PCRV model test results with analysis

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Belytschko, T.B.

    1979-01-01

    Comparisons are made of transient data derived from simple models of a reactor containment vessel with analytical solutions. This effort is a part of the ongoing process of development and testing of the DYNAPCON computer code. The test results used in these comparisons were obtained from scaled models of the British sodium cooled fast breeder program. The test structure is a scaled model of a cylindrically shaped reactor containment vessel made of concrete. This concrete vessel is prestressed axially by holddown bolts spanning the top and bottom slabs along the cylindrical walls, and is also prestressed circumferentially by a number of cables wrapped around the vessel. For test purposes this containment vessel is partially filled with water, which comes in direct contact with the vessel walls. The explosive charge is immersed in the pool of water and is centrally suspended from the top of the vessel. The load history was obtained from an ICECO analysis, using the equations of state for the source and the water. A detailed check of this solution was made to assure that the derived loading did provide the correct input. The DYNAPCON code was then used for the analysis of the prestressed concrete containment model. This analysis required the simulation of prestressing and the response of the model to the applied transient load. The calculations correctly predict the magnitudes of displacements of the PCRV model. In addition, the displacement time histories obtained from the calculations reproduce the general features of the experimental records: the period elongation and amplitude increase as compared to an elastic solution, and also the absence of permanent displacement. However, the period still underestimates the experiment, while the amplitude is generally somewhat large

  10. Synopsis of the results of ISP-39 on FARO test L-14

    Energy Technology Data Exchange (ETDEWEB)

    Addabbo, C.; Annunziato, A.; Magallon, D. [Commission of the European Communities, Ispra (Italy). Joint Research Center

    1998-01-01

    This paper provides a synopsis of the salient results from the ISP(International Standard Problem)-39 exercise promoted by OECD-CSNI in the frame of the NEA activities aimed at fostering international cooperation in reactor safety research and development. ISP-39 has been conceived to benchmark the predictive capabilities of computer codes used in the evaluation of FCI and quenching phenomenologies of relevance in water cooled reactors severe accidents safety analysis. The ISP-39 reference case is FARO test L-14, a non-energetic FCI test performed in the FARO experimental installation under realistic melt composition and prototypical test conditions. (author)

  11. ASME N510 test results for Savannah River Site AACS filter compartments

    Energy Technology Data Exchange (ETDEWEB)

    Paul, J.D.; Punch, T.M. [Westinghouse Savannah River Company, Aiken, SC (United States)

    1995-02-01

    The K-Reactor at the Savannah River Site recently implemented design improvements for the Airborne Activity Confinement System (AACS) by procuring, installing, and testing new Air Cleaning Units, or filter compartments, to ASME AG-11, N509, and N510 requirements. Specifically, these new units provide documentable seismic resistance to a Design Basis Accident earthquake, provide 2 inch adsorber beds with 0.25 second residence time, and meet all AG-1, N509, and N510 requirements for testability and maintainability. This paper presents the results of the Site acceptance testing and discusses an issue associated with sample manifold qualification testing.

  12. Results of crack-arrest tests on irradiated a 508 class 3 steel

    International Nuclear Information System (INIS)

    Iskander, S.K.; Milella, P.P.; Pini, M.A.

    1998-02-01

    Ten crack-arrest toughness values for irradiated specimens of A 508 class 3 forging steel have been obtained. The tests were performed according to the American Society for Testing and Materials (ASTM) Standard Test Method for Determining Plane-Strain Crack-Arrest Fracture Toughness, K la of Ferritic Steels, E 1221-88. None of these values are strictly valid in all five ASTM E 1221-88 validity criteria. However, they are useful when compared to unirradiated crack-arrest specimen toughness values since they show the small (averaging approximately 10 degrees C) shifts in the mean and lower-bound crack-arrest toughness curves. This confirms that a low copper content in ASTM A 508 class 3 forging material can be expected to result in small shifts of the transition toughness curve. The shifts due to neutron irradiation of the lower bound and mean toughness curves are approximately the same as the Charpy V-notch (CVN) 41-J temperature shift. The nine crack-arrest specimens were irradiated at temperatures varying from 243 to 280 degrees C, and to a fluence varying from 1.7 to 2.7 x 10 19 neutrons/cm 2 (> 1 MeV). The test results were normalized to reference values that correspond to those of CVN specimens irradiated at 284 degrees C to a fluence of 3.2 x 10 19 neutrons/cm 2 (> 1 MeV) in the same capsule as the crack-arrest specimens. This adjustment resulted in a shift to lower temperatures of all the data, and in particular moved two data points that appeared to lie close to or lower than the American Society of Mechanical Engineers K la curve to positions that seemed more reasonable with respect to the remaining data. A special fixture was designed, fabricated, and successfully used in the testing. For reasons explained in the text, special blocks to receive the Oak Ridge National Laboratory clip gage were designed, and greater-than-standard crack-mouth opening displacements measured were accounted for. 24 refs., 13 figs., 12 tabs

  13. Results of Sludge Mobilization Testing at Hanford High Level Waste (HLW) Tank

    International Nuclear Information System (INIS)

    STAEHR, T.W.

    2001-01-01

    Waste stored in the Tank 241-AZ-101 at the US DOE Hanford is scheduled as the initial feed for high-level waste vitrification. Tank 241-AZ-101 currently holds over 3,000,000 liters of waste made up of a settled sludge layer covered by a layer of liquid supernant. To retrieve the waste from the tank, it is necessary to mobilize and suspend the settled sludge so that the resulting slurry can be pumped from the tank for treatment and vitrification. Two 223.8-kilowatt mixer pumps have been installed in Tank 241-AZ-101 to mobilize the settled sludge layer of waste for retrieval. In May of 2000, the mixer pumps were subjected to a series of tests to determine (1) the extent to which the mixer pumps could mobilize the settle sludge layer of waste, (2) if the mixer pumps could function within operating parameters, and (3) if state-of-the-art monitoring equipment could effectively monitor and quantify the degree of sludge mobilization and suspension. This paper presents the major findings and results of the Tank 241-AZ-101 mixer pump tests, based on analysis of data and waste samples that were collected during the testing. Discussion of the results focuses on the effective cleaning radius achieved and the volume and concentration of sludge mobilized, with both one and two pumps operating in various configurations and speeds. The Tank 241-AZ-101 mixer pump tests were unique in that sludge mobilization parameters were measured using actual waste in an underground storage tank at the hanford Site. The methods and instruments that were used to measure waste mobilization parameters in Tank 241-AZ-101 can be used in other tanks. It can be concluded from the testing that the use of mixer pumps is an effective retrieval method for the mobilization of settled solids in Tank 241-AZ-101

  14. Patient-reported speech in noise difficulties and hyperacusis symptoms and correlation with test results.

    Science.gov (United States)

    Spyridakou, Chrysa; Luxon, Linda M; Bamiou, Doris E

    2012-07-01

    To compare self-reported symptoms of difficulty hearing speech in noise and hyperacusis in adults with auditory processing disorders (APDs) and normal controls; and to compare self-reported symptoms to objective test results (speech in babble test, transient evoked otoacoustic emission [TEOAE] suppression test using contralateral noise). A prospective case-control pilot study. Twenty-two participants were recruited in the study: 10 patients with reported hearing difficulty, normal audiometry, and a clinical diagnosis of APD; and 12 normal age-matched controls with no reported hearing difficulty. All participants completed the validated Amsterdam Inventory for Auditory Disability questionnaire, a hyperacusis questionnaire, a speech in babble test, and a TEOAE suppression test using contralateral noise. Patients had significantly worse scores than controls in all domains of the Amsterdam Inventory questionnaire (with the exception of sound detection) and the hyperacusis questionnaire (P reported symptoms of difficulty hearing speech in noise and speech in babble test results in the right ear (ρ = 0.624, P = .002), and between self-reported symptoms of hyperacusis and TEOAE suppression test results in the right ear (ρ = -0.597 P = .003). There was no significant correlation between the two tests. A strong correlation was observed between right ear speech in babble and patient-reported intelligibility of speech in noise, and right ear TEOAE suppression by contralateral noise and hyperacusis questionnaire. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  15. Analysis of results of oral glucose tolerance test (OGTT) and insulin releasing test in hepatogenic diabetics

    International Nuclear Information System (INIS)

    He Haoming; Fu Qiang; Tian Xiaoping; Su Cainu

    2001-01-01

    Objective: To explore the clinical values of OGTT and insulin releasing test in hepatogenic diabetics. Method: OGTT was performed by enzymes method and insulin releasing test by RIA in 30 patients with hepatogenic diabetes, 31 cases with II diabetes and 35 controls. Results: During OGTT, blood glucose levels at various time were about the same in hepatogenic diabetics and II diabetics (P < 0.05), except at 180 min (P < 0.01). Basal hyperinsulinemia was present is hepatogenic diabetics. Conclusion: OGTT and insulin releasing test had a definite clinical value in the differential diagnosis of hepatogenic diabetics

  16. Advances in the diagnosis of hereditary kidney cancer: Initial results of a multigene panel test.

    Science.gov (United States)

    Nguyen, Kevin A; Syed, Jamil S; Espenschied, Carin R; LaDuca, Holly; Bhagat, Ansh M; Suarez-Sarmiento, Alfredo; O'Rourke, Timothy K; Brierley, Karina L; Hofstatter, Erin W; Shuch, Brian

    2017-11-15

    Panel testing has been recently introduced to evaluate hereditary cancer; however, limited information is available regarding its use in kidney cancer. The authors retrospectively reviewed test results and clinical data from patients who underwent targeted multigene panel testing of up to 19 genes associated with hereditary kidney cancer from 2013 to 2016. The frequency of positive (mutation/variant likely pathogenic), inconclusive (variant of unknown significance), and negative results was evaluated. A logistic regression analysis evaluated predictive factors for a positive test. Patients (n = 1235) had a median age at diagnosis of 46 years, which was significantly younger than the US population of individuals with kidney cancer (P kidney cancer. Panel tests may be particularly useful for patients who lack distinguishing clinical characteristics of known hereditary kidney cancer syndromes. The current results support the use of early age of onset for genetic counseling and/or testing. Cancer 2017;123:4363-71. © 2017 American Cancer Society. © 2017 American Cancer Society.

  17. Full scale test results for ship ice impact forces and pressures

    International Nuclear Information System (INIS)

    Ghoneim, G.A.

    1993-01-01

    A set of full scale impact tests were carried out for the icebreakers Canmar Kigoriak and Robert LeMeur in first and multi-year ice conditions in the southern Beaufort Sea. Preliminary results of the testing program were published in Ghoneim et al. (1984). This paper presents some salient results of further analysis of the data. This includes a description of the different types of ice ramming mechanisms and the corresponding ice force time histories and ship response. A comparison between the bow force peak values for the kigoriak and the Robert LeMeur is made and the reasons for the difference are evaluated. The question of dynamic magnification of the response is investigated. The relationship between the peak impact force and the ramming velocity is evaluated for both ships and compared with theoretical and empirical formulations. Other parametric relationships are presented, including such parameters as force duration and relative magnitude of the impact and beaching bow forces. The added mass is evaluated from measured accelerations and calculated bow forces and are shown to be time dependent. The relationship between ice pressure and corresponding contact area is discussed. Finally, conclusions and recommendations are presented

  18. Results of industrial tests of carbonate additive to fuel oil

    Science.gov (United States)

    Zvereva, E. R.; Dmitriev, A. V.; Shageev, M. F.; Akhmetvalieva, G. R.

    2017-08-01

    Fuel oil plays an important role in the energy balance of our country. The quality of fuel oil significantly affects the conditions of its transport, storage, and combustion; release of contaminants to atmosphere; and the operation of main and auxiliary facilities of HPPs. According to the Energy Strategy of Russia for the Period until 2030, the oil-refining ratio gradually increases; as a result, the fraction of straight-run fuel oil in heavy fuel oils consistently decreases, which leads to the worsening of performance characteristics of fuel oil. Consequently, the problem of the increase in the quality of residual fuel oil is quite topical. In this paper, it is suggested to treat fuel oil by additives during its combustion, which would provide the improvement of ecological and economic indicators of oil-fired HPPs. Advantages of this method include simplicity of implementation, low energy and capital expenses, and the possibility to use production waste as additives. In the paper, the results are presented of industrial tests of the combustion of fuel oil with the additive of dewatered carbonate sludge, which is formed during coagulation and lime treatment of environmental waters on HPPs. The design of a volume delivery device is developed for the steady additive input to the boiler air duct. The values are given for the main parameters of the condition of a TGM-84B boiler plant. The mechanism of action of dewatered carbonate sludge on sulfur oxides, which are formed during fuel oil combustion, is considered. Results of industrial tests indicate the decrease in the mass fraction of discharged sulfur oxides by 36.5%. Evaluation of the prevented damage from sulfur oxide discharged into atmospheric air shows that the combustion of the fuel oil of 100 brand using carbonate sludge as an additive (0.1 wt %) saves nearly 6 million rubles a year during environmental actions at the consumption of fuel oil of 138240 t/year.

  19. HEDL W-1 SLSF experiment LOPI transient and boiling test results

    International Nuclear Information System (INIS)

    Henderson, J.M.; Wood, S.A.; Rothrock, R.B.

    1980-01-01

    The W-1 Sodium Loop Safety Facility (SLSF) experiment was designed to study the heat release characteristics of fast reactor fuel pins under Loss-of-Piping-Integrity (LOPI) accident conditions and determine stable sodium boiling initiation and recovery limits in a prototypic fuel pin bundle array. The results of the experiment address major second level of assurance (LOA-2) safety issues and provide increased insight and understanding of phenomena that would inherently terminate hypothesized accidents with only limited core damage. The irradiation phase of the experiment, consisting of thirteen individual transients, was performed between May 27 and July 20, 1979. The final transient produced approximately two seconds of coolant boiling, cladding dryout, and incipient fuel pin failure. The facility and test hardware performed as designed, allowing completion of all planned tests and achievement of all test objectives

  20. Results of Ageing Tests on the Forward MSGC 'BANANA' Prototype

    CERN Document Server

    Boimska, B; Capéans-Garrido, M; Claes, S; Hoch, Michael; Million, Gilbert; Ropelewski, Leszek; Sharma, Abhishek; Shekhtman, L I; Van Doninck, Walter; Van Lancker, Luc

    1996-01-01

    The forward tracker of the CMS experiment at CERN will consist of a large number of MicroStrip Gas Chambers ( MSGCs), expected to operate for several years in the high luminosity environment of LHC with an accumulated dose rate of ~ 10 mC/yr per cm of strip. They are planned to be arranged around the interaction point in modular wheels which contain several MSGCs. The 'open'option of a forward CMS 'banana' module includes the electronics inside the gas volume. Long term tests of one such prototype containing two plates, one with gold and the other with chromium strips on diamond-like coated D263 glass with representative electronics and surface mount components inside the gas volume have been performed; the satisfactory results are reported here. A first test has been made with a gas flow rate of 60 cc/min in the prototype ( corresponding to 5 gas renewals per hour) and has shown no gain drop up to 85 mC/cm of accumulated charge per strip. A second test has been performed with a gas flow rate of 6 cc/min corr...

  1. Comparison of ASTECV1.3.2 and ASTECV2 results for QUENCH 12 test

    International Nuclear Information System (INIS)

    Stefanova, A.

    2010-01-01

    This paper presents a comparison of QUENCH 12 test calculated results with ASTECv1.3R2 and ASTECv2 computer codes. The test was performed to investigate the behavior of VVER fuel assemblies. This investigation is a part of the 6th and 7th framework programs of the EC supported ISTC program. The test facility is located at Forschungszentrum in Karlsruhe. The structure of the test facility allows experimental studies under transient and accident conditions. The ASTEC1.3R2 and ASTECv2 computer codes have been used to simulate the investigated test. The base line input model for ASTEC was provided from Forschungszentrum, Karlsruhe. During the preparation of QUENCH - 12 experiment, the input deck was adapted to new initial and boundary conditions. The comparison show good agreement between measured data and ASTEC calculated results. (author)

  2. Results from evaporation tests to support the MWTF heat removal system design

    International Nuclear Information System (INIS)

    Crea, B.A.

    1994-01-01

    An experimental tests program was conducted to measure the evaporative heat removal from the surface of a tank of simulated waste. The results contained in this report constitute definition design data for the latest heat removal function of the MWTF primary ventilation system

  3. The tritium systems test assembly: Overview and recent results

    International Nuclear Information System (INIS)

    Bartlit, J.R.; Anderson, J.L.

    1988-01-01

    The fusion technology development program for tritium in the US is centered around the Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory. The TSTA is a full-scale system of reactor exhaust gas reprocessing for an ITER-sized machine. That is, TSTA has the capacity to process tritium in a closed loop mode at the rate of 1 kg per day, requiring a tritium inventory of about 100 g. The TSTA program also interacts with all other tritium-related fusion technology programs in the US and all major programs abroad. This report summarizes the current status, results and interactions of the TSTA. Special emphasis is given to operations in May/June using large compound cryopumps that completed the fuel loop integration of all TSTA subsystems for the first time. 6 refs., 2 figs

  4. Results from EQAS 2002

    DEFF Research Database (Denmark)

    Petersen, A.; Aarestrup, Frank Møller; Jensen, A.B.

    An international external quality assurance program on serotyping and antimicrobial susceptibility testing of eight Salmonella enterica strains was performed to enhance the capacity of national and regional reference laboratories in WHO Global Salm-Surv (WHO GSS). In 2002 a total of 117 laborator......An international external quality assurance program on serotyping and antimicrobial susceptibility testing of eight Salmonella enterica strains was performed to enhance the capacity of national and regional reference laboratories in WHO Global Salm-Surv (WHO GSS). In 2002 a total of 117...... laboratories from 67 countries participated. For serotyping, almost 90 % of the results were correct. For susceptibility testing, 91 % of the results were in agreement with the expected results, and 86 % of the performed tests with the reference strain E. coli ATCC 25922 were inside the quality control range...

  5. The conformity of BPP and vibroacoustic stimulation results in fetal non reactive non stress test

    Directory of Open Access Journals (Sweden)

    M. Modarres

    2006-08-01

    Full Text Available Background: The most frequently used test for evaluation of fetal health is the Non Stress Test (NST. Unfortunately it has a high incidence of false positive results. The combination of vibroacoustic stimulation with the NTS has been shown to reduce non reactive results. Methods: A tests assessment method was chosen with a simple randomized sampling. 40 pregnant women with non reactive NST in the first 20 minutes who received VAS in one of Tehran University's Hospitals were compared with BPP scores. A vibroacoustic stimulation was applied for a 3 seconds on the maternal abdomen and fallowed within 10 minutes.Data collection tools were NST, sonography instruments ,NST result paper, tooth brusher, watch, demographic questioner and check list. Data analysis was made by descriptive static and by using the Fisher's Exact Test (with level of significant at p<0/05. All statistical analysis were performed using an spss/win. Results: After VAS, 70% of non reactive tracing became reactive. All cases with fetal reactivity response after a VAS had a subsequent BPP score of 8 (negative predictive value of 100%. False positivity of VAS was lower than NST. Conclusion: VAS offers benefits, by decreasing the incidence of non reactive test and reducing test time. VAS lowers the rate of false positive NST. VAS is safe and allows more efficient of prenatal services. This test could be used as a rapid antepartum test to predict fetal well-being.

  6. Air Monitoring Network at Tonopah Test Range: Network Description, Capabilities, and Analytical Results

    International Nuclear Information System (INIS)

    Hartwell, William T.; Daniels, Jeffrey; Nikolich, George; Shadel, Craig; Giles, Ken; Karr, Lynn; Kluesner, Tammy

    2012-01-01

    During the period April to June 2008, at the behest of the Department of Energy (DOE), National Nuclear Security Administration, Nevada Site Office (NNSA/NSO); the Desert Research Institute (DRI) constructed and deployed two portable environmental monitoring stations at the Tonopah Test Range (TTR) as part of the Environmental Restoration Project Soils Activity. DRI has operated these stations since that time. A third station was deployed in the period May to September 2011. The TTR is located within the northwest corner of the Nevada Test and Training Range (NTTR), and covers an area of approximately 725.20 km2 (280 mi2). The primary objective of the monitoring stations is to evaluate whether and under what conditions there is wind transport of radiological contaminants from Soils Corrective Action Units (CAUs) associated with Operation Roller Coaster on TTR. Operation Roller Coaster was a series of tests, conducted in 1963, designed to examine the stability and dispersal of plutonium in storage and transportation accidents. These tests did not result in any nuclear explosive yield. However, the tests did result in the dispersal of plutonium and contamination of surface soils in the surrounding area.

  7. Evaluation of LLTR Series II Test A-3 results

    International Nuclear Information System (INIS)

    Amos, J.C.; Chen, K.; Meyer, R.A.; Odegaard, T.K.; Whipple, J.C.

    1980-11-01

    Of the five secondary tubes failed in Test A-3, two were failed by impingement wastage, and the other three appear to have been caused by overheating possibly augmented by wastage. Since no secondary tube failures occurred during large leak tests, this spports the hypthesis that a small initial leak can create much more damage on neighboring tubes than an initial large leak. The overheating falures occurred in about 20 seconds after a second large hole had been produced in a thin wall (non-prototypical) primary tube. Continued water injection under static or low sodium flow conditions following an initial small leak will produce high temperatures which can result in deformation (bowing) of 2-1/4 Cr-1 Mo steam tubes and interference at the tube-tubespacer interface. The damage caused by either impingement wastage or overheating will occur at or above the elevation plane of the initial leak. If water/steam injection continues after removal of the sodium, water steam blanketing will cool the tubes heated by the SWR. Additional tube failures can be caused by overheating prior to rupture disc operation when leak rate is increased by secondary tube penetrations caused by wastage. Acoustic emission measurement provides a rapid means of leak detection for intermediate size leaks

  8. Results from Carbon Dioxide Washout Testing Using a Suited Manikin Test Apparatus with a Space Suit Ventilation Test Loop

    Science.gov (United States)

    Chullen, Cinda; Conger, Bruce; McMillin, Summer; Vonau, Walt; Kanne, Bryan; Korona, Adam; Swickrath, Mike

    2016-01-01

    NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS is one of the most critical aspects of the space suit providing the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The ventilation subsystem in the PLSS must provide sufficient carbon dioxide (CO2) removal and ensure that the CO2 is washed away from the oronasal region of the astronaut. CO2 washout is a term used to describe the mechanism by which CO2 levels are controlled within the helmet to limit the concentration of CO2 inhaled by the astronaut. Accumulation of CO2 in the helmet or throughout the ventilation loop could cause the suited astronaut to experience hypercapnia (excessive carbon dioxide in the blood). A suited manikin test apparatus (SMTA) integrated with a space suit ventilation test loop was designed, developed, and assembled at NASA in order to experimentally validate adequate CO2 removal throughout the PLSS ventilation subsystem and to quantify CO2 washout performance under various conditions. The test results from this integrated system will be used to validate analytical models and augment human testing. This paper presents the system integration of the PLSS ventilation test loop with the SMTA including the newly developed regenerative Rapid Cycle Amine component used for CO2 removal and tidal breathing capability to emulate the human. The testing and analytical results of the integrated system are presented along with future work.

  9. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Maerker, R.E.; Stallmann, F.W.

    1984-01-01

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  10. Radiation Testing on State-of-the-Art CMOS: Challenges, Plans, and Preliminary Results

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2009-01-01

    At GOMAC 2007 and 2008, we discussed a variety of challenges for radiation testing of modern semiconductor devices and technologies [1, 2]. In this presentation, we provide more specific details in this on-going investigation focusing on out-of-the-box lessons observed for providing radiation effects assurances as well as preliminary test results.

  11. Comparison of analysis results with experimental results for ENEA and CRIEPI rubber bearings

    International Nuclear Information System (INIS)

    Yoo, B.; Lee, J.H.; Koo, G.H.

    1993-01-01

    In this paper, the preliminary structural analyses of ENEA HDRB and CRIEPI NRB were performed by using computer code ABAQUS, and the analysis results were compared with the test results provided by Italy and Japan thru IAEA. The test data for the rubbers used for the fabrication of bearings were also provided thru IAEA, and were utilized for the formulation of the rubber models for the analyses. The analyses performed for the rubber bearings are for the combined compression and shear and for the compression. The analysis results show a good agreement in shear strains when compared with the test results of HDRB and NRB for the combined compression and shear and for the compression benchmarks, but show relatively smaller responses in displacements for the compression with offsets benchmarks. (author)

  12. Integrated vehicle-based safety systems light-vehicle field operational test, methodology and results report.

    Science.gov (United States)

    2010-12-01

    "This document presents the methodology and results from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michi...

  13. Flight test results for the Daedalus and Light Eagle human powered aircraft

    Science.gov (United States)

    Sullivan, R. Bryan; Zerweckh, Siegfried H.

    1988-01-01

    The results of the flight test program of the Daedalus and Light Eagle human powered aircraft in the winter of 1987/88 are given. The results from experiments exploring the Light Eagle's rigid body and structural dynamics are presented. The interactions of these dynamics with the autopilot design are investigated. Estimates of the power required to fly the Daedalus aircraft are detailed. The system of sensors, signal conditioning boards, and data acquisition equipment used to record the flight data is also described. In order to investigate the dynamics of the aircraft, flight test maneuvers were developed to yield maximum data quality from the point of view of estimating lateral and longitudinal stability derivatives. From this data, structural flexibility and unsteady aerodynamics have been modeled in an ad hoc manner and are used to augment the equations of motion with flexibility effects. Results of maneuvers that were flown are compared with the predictions from the flexibility model. To extend the ad hoc flexibility model, a fully flexible aeroelastic model has been developed. The model is unusual in the approximate equality of many structural natural frequencies and the importance of unsteady aerodynamic effects. the Gossamer Albatross. It is hypothesized that this inverse ground effect is caused by turbulence in the Earth's boundary layer. The diameters of the largest boundary layer eddies (which represent most of the turbulent kinetic energy) are proportional to altitude; thus, closer to the ground, the energy in the boundary layer becomes concentrated in eddies of smaller and smaller diameter. Eventually the eddies become sufficiently small (approximately 0.5 cm) that they trip the laminar boundary layer on the wing. As a result, a greater percentage of the wing area is covered with turbulent flow. Consequently the aircraft's drag and the pow er required both increase as the aircraft flies closer to the ground. The results of the flight test program are

  14. Dynamic Analysis and Test Results for an STC Stirling Generator

    Science.gov (United States)

    Qiu, Songgang; Peterson, Allen A.

    2004-02-01

    Long-life, high-efficiency generators based on free-piston Stirling machines are a future energy-conversion solution for both space and commercial applications. To aid in design and system integration efforts, Stirling Technology Company (STC) has developed dynamic simulation models for the internal moving subassemblies and for complete Stirling convertor assemblies. These dynamic models have been validated using test data from operating prototypes. Simplified versions of these models are presented to help explain the operating characteristics of the Stirling convertor. Power spectrum analysis is presented for the test data for casing acceleration, piston motion, displacer motion, and controller current/voltage during full power operation. The harmonics of a Stirling convertor and its moving components are identified for the STC zener-diode control scheme. The dynamic behavior of each moving component and its contribution to the system dynamics and resultant vibration forces are discussed. Additionally, the effects of a passive balancer and external suspension are predicted by another simplified system model.

  15. Structural damping results from vibration tests of straight piping sections

    International Nuclear Information System (INIS)

    Ware, A.G.; Thinnes, G.L.

    1984-01-01

    EG and G Idaho is assisting the USNRC and the Pressure Vessel Research Committee in supporting a final position on revised damping values for structural analyses of nuclear piping systems. As part of this program, a series of vibrational tests on 76-mm and 203-mm (3-in. amd 8-in.) Schedule 40 carbon steel piping was conducted to determine the changes in structural damping due to various parametric effects. The 10-m (33-ft) straight sections of piping were rigidly supported at the ends. Spring, rod, and constant force hangers, as well as a sway brace and snubbers were included as intermediate supports. Excitation was provided by low-force level hammer inpacts, a hydraulic shaker, and a 445-kN (50-ton) overhead crane. Data was recorded using acceleration, strain, and displacement time histories. This paper presents results from the testing showing the effect of stress level and type of supports on structural damping in piping

  16. Test results and in-orbit operation of the Infrared Astronomical Satellite circumvention circuit

    Science.gov (United States)

    Long, E. C.; Langford, D.

    1984-01-01

    The IRAS circumvention circuit (CC) eliminates the unwanted charged-particle pulses from the IR signal. The operation of the CC along with preflight and in-orbit testing is described. Ground testing of the brassboard circuit using a simulated preamplifier output showed that the CC would perform the circumvention function as designed. When all flight detectors and preamplifiers became available, the CC was tested using a gamma source to simulate charged-particle sources; with the low energy deposited in the detectors (20 keV average) the noise was reduced by up to 5 times with the CC turned on. In-orbit results show that the CC decreases the unwanted charged-particle background noise by up to two orders of magnitude. The difference in the results with the CC on and off is so great that the science team has recommended that no data be taken with the CC off.

  17. The Influence of Instrumented Striker Configuration on the Results of Dynamic Toughness Testing

    International Nuclear Information System (INIS)

    Lucon, E.

    2008-01-01

    Several studies are available on the influence of the edge radius of instrumented strikers (ASTM - 8 mm or ISO - 2 mm) on the results of both non instrumented and instrumented Charpy tests. This paper investigates the effect of using either a 2 mm or a 8 mm striker when performing dynamic toughness tests at impact loading rates on precracked Charpy specimens. Existing data from tests run in the ductile-to-brittle region (dynamic Master Curve reference temperature) and in the upper shelf regime (ductile initiation fracture toughness and crack resistance curves) have been analyzed. The results show that 2 mm strikers tend to yield lower cleavage fracture toughness in the transition region (although the effect cannot be considered statistically significant), whereas the influence of striker configuration is negligible in the upper shelf regime when data are generated using the low-blow multiple-specimen technique.

  18. The Influence of Instrumented Striker Configuration on the Results of Dynamic Toughness Testing

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.

    2008-09-15

    Several studies are available on the influence of the edge radius of instrumented strikers (ASTM - 8 mm or ISO - 2 mm) on the results of both non instrumented and instrumented Charpy tests. This paper investigates the effect of using either a 2 mm or a 8 mm striker when performing dynamic toughness tests at impact loading rates on precracked Charpy specimens. Existing data from tests run in the ductile-to-brittle region (dynamic Master Curve reference temperature) and in the upper shelf regime (ductile initiation fracture toughness and crack resistance curves) have been analyzed. The results show that 2 mm strikers tend to yield lower cleavage fracture toughness in the transition region (although the effect cannot be considered statistically significant), whereas the influence of striker configuration is negligible in the upper shelf regime when data are generated using the low-blow multiple-specimen technique.

  19. Test and analysis results for two Synergy Power Corp. wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Davis, D.; Hansen, C. [Windward Engineering, L.C., Salt Lake City, UT (United States)

    1996-12-31

    The testing and modeling of small (rotor diameter 10.3 m and 12.8 m) wind turbines is the subject of this paper. The paper focuses primarily on the ADAMS computer model for dynamic analysis. The code calculates design loads, optimizes tilt configuration, and helps to interpret test results. A comparison of some of the modeling predictions is made to test data for validation purposes. The ADAMS model was found to accurately predict performance characteristics and loads for free-tilting turbines. ADAMS was found to be relatively successful in modeling the free tilt and variable rotors. The model also showed that tilting behavior is dependent on the restoring moment from the rotor aerodynamics as well as on surface aerodynamics. The effects of changes in air density on the power curve, load predictions, and analysis of emergency stops were also performed satisfactorily with the model. 15 figs.

  20. Patch and Prick Tests in Hand Eczema: Results of A Sixty Seven Patient Series

    Directory of Open Access Journals (Sweden)

    Bilge Fettahlıoğlu Karaman

    2017-12-01

    Full Text Available Objective: The patch and prick tests have a place in the management of patients with hand eczema. In this study, we investigated whether some of the clinical features patients with hand eczema could provide us with the predictability of skin test results. Methods: In Çukurova University Faculty of Medicine, 67 consecutive patients with hand eczema; evaluated in terms of duration of disease, morphology and severity. All of the patients were undergoes patch tested with the European Standard Series, and needle testing with routine aeroallergens. Results: Patch test with at least one allergen was positive in 46.3% of the patients; wheras this rate was 23.9% for prick test. The likelihood of having a contact sensitivity of patients complaining of hand eczema for at least three years was statistically more significant [odds ratio (OR 0.9]. Although statistically not significant, it is less likely to be sensitized to patients with keratotic and/or licheniform hand eczema (OR 0.3. The severity of hand eczema was not predictive of patch test, there was no indicator of needle test positivity. Conclusion: We strongly recommend patch testing in all patients with prolonged hand eczema.

  1. Test results for cables used in nuclear power plants by a new environmental testing method

    Energy Technology Data Exchange (ETDEWEB)

    Handa, Katsue; Fujimura, Shun-ichi; Hayashi, Toshiyasu; Takano, Keiji; Oya, Shingo

    1982-12-01

    In the nuclear power plants using PWRs or BWRs in Japan, environmental tests are provided, in which simulated LOCA conditions are considered so as to conform with Japanese conditions, and many cables which passed these tests are presently employed. Lately, the new environmental testing, in which a credible accident called MSLB (main steam line breakage) is taken into account, is investigated in PWR nuclear power plants, besides LOCA. This paper reports on the results of evaluating some PWR cables for this new environmental testing conditions. The several cables tested were selected out of PH cables (fire-retardant, ethylene propylene rubber insulated, chlorosulfonated polyethylene sheathed cables) as the cables for safety protecting circuits and to be used in containment vessels where the cables are to be exposed to severe environmental test conditions of 2 x 10/sup 8/ Rad ..gamma..-irradiation and simulated LOCA. All these cables have been accepted after the vertical tray burning test provided in the IEEE Standard 383. The new testing was carried out by sequentially applying thermal deterioration, ..gamma..-irradiation, and the exposure to steam (twice 300 s exposures to 190 deg C superheated steam). After completing each step, tensile strength, elongation, insulation resistance and breakdown voltage were measured, respectively. Every cable tested showed satisfactory breakdown voltage after the exposure to steam, thus it was decided to be acceptable. In future, it is required to investigate the influence of the rate of temperature rise on the cable to be tested in MSLB simulation.

  2. Results of recent reactor-material tests on dispersal of oxide fuel from a disrupted core

    International Nuclear Information System (INIS)

    Spencer, B.W.; Wilson, R.J.; Vetter, D.L.; Erickson, E.G.; Dewey, G.

    1985-01-01

    The results of experimental investigations and related analyses are reported addressing the dispersal of molten oxide fuel from a disrupted core via various available pathways for the CRBR system. These investigations included the GAPFLOW tests in which pressure-driven and gravity drainage tests were performed using dispersal pathways mocking up the intersubassembly gaps, the CAMEL C6 and C7 tests in which molten fuel entered sodium-filled control assembly ducts under prototypic thermal-hydraulic conditions, and the Lower Internals Drainage (LID) tests in which molten fuel drained downward through simulated below-core structure (orifice plate stacks) as the bottom of control assembly ducts. The results of SHOTGUN tests addressing basic freezing of molten UO 2 and UO 2 /metal mixtures flowing through circular tubes are also reported. Test results have invariably shown the existance of stable UO 2 crusts on the inside surfaces of the flow paths. Appreciable removal of fuel was indicated prior to freezing-induced immobilization. Application of heat transfer models based upon the presence of stable, insulating fuel crusts tends to overpredict the removal process

  3. [Do different interpretative methods used for evaluation of checkerboard synergy test affect the results?].

    Science.gov (United States)

    Ozseven, Ayşe Gül; Sesli Çetin, Emel; Ozseven, Levent

    2012-07-01

    In recent years, owing to the presence of multi-drug resistant nosocomial bacteria, combination therapies are more frequently applied. Thus there is more need to investigate the in vitro activity of drug combinations against multi-drug resistant bacteria. Checkerboard synergy testing is among the most widely used standard technique to determine the activity of antibiotic combinations. It is based on microdilution susceptibility testing of antibiotic combinations. Although this test has a standardised procedure, there are many different methods for interpreting the results. In many previous studies carried out with multi-drug resistant bacteria, different rates of synergy have been reported with various antibiotic combinations using checkerboard technique. These differences might be attributed to the different features of the strains. However, different synergy rates detected by checkerboard method have also been reported in other studies using the same drug combinations and same types of bacteria. It was thought that these differences in synergy rates might be due to the different methods of interpretation of synergy test results. In recent years, multi-drug resistant Acinetobacter baumannii has been the most commonly encountered nosocomial pathogen especially in intensive-care units. For this reason, multidrug resistant A.baumannii has been the subject of a considerable amount of research about antimicrobial combinations. In the present study, the in vitro activities of frequently preferred combinations in A.baumannii infections like imipenem plus ampicillin/sulbactam, and meropenem plus ampicillin/sulbactam were tested by checkerboard synergy method against 34 multi-drug resistant A.baumannii isolates. Minimum inhibitory concentration (MIC) values for imipenem, meropenem and ampicillin/sulbactam were determined by the broth microdilution method. Subsequently the activity of two different combinations were tested in the dilution range of 4 x MIC and 0.03 x MIC in

  4. Testing results of Monte Carlo sampling processes in MCSAD

    International Nuclear Information System (INIS)

    Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, A.; Correa, C.; Demydenko, C.

    2009-01-01

    The Monte Carlo Simulation of Atom Displacements (MCSAD) is a code implemented by the authors to simulate the complete process of atom displacement (AD) formation. This code makes use of the Monte Carlo (MC) method to sample all the processes involved in the gamma and electronic radiation transport through matter. The kernel of the calculations applied to this code relies on a model based on an algorithm developed by the authors, which firstly splits out multiple electron elastic scattering events from those single ones at higher scattering angles and then, from the last one, sampling those leading to AD at high transferred atomic recoil energies. Some tests have been developed to check the sampling algorithms with the help of the corresponding theoretical distribution functions. Satisfactory results have been obtained, which indicate the strength of the methods and subroutines used in the code. (Author)

  5. Advanced stellar compass deep space navigation, ground testing results

    DEFF Research Database (Denmark)

    Betto, Maurizio; Jørgensen, John Leif; Jørgensen, Peter Siegbjørn

    2006-01-01

    Deep space exploration is in the agenda of the major space agencies worldwide and at least the European Space Agency (SMART & Aurora Programs) and the American NASA (New Millennium Program) have set up programs to allow the development and the demonstration of technologies that can reduce the risks...... and the costs of the deep space missions. Navigation is the Achilles' heel of deep space. Being performed on ground, it imposes considerable constraints on the system and the operations, it is very expensive to execute, especially when the mission lasts several years and, above all, it is not failure tolerant...... to determine the orbit of a spacecraft autonomously, on-board and without any a priori knowledge of any kind. The solution is robust, elegant and fast. This paper presents the preliminary performances obtained during the ground tests. The results are very positive and encouraging....

  6. SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

    Science.gov (United States)

    Winternitz, Luke; Mitchell, Jason W.; Hassouneh, Munther A.; Valdez, Jennifer E.; Price, Samuel R.; Semper, Sean R.; Yu, Wayne H.; Ray, Paul S.; Wood, Kent S.; Arzoumanian, Zaven; hide

    2016-01-01

    The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the high-fidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars

  7. Linear Array Ultrasonic Test Results from Alkali-Silica Reaction (ASR) Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Khazanovich, Dr. Lev [Univ. of Minnesota, Minneapolis, MN (United States); Salles, Lucio [Univ. of Minnesota, Minneapolis, MN (United States)

    2016-04-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.This report presents results of the ultrasound evaluation of four concrete slabs with varying levels of ASR damage present. This included an investigation of the experimental results, as well as a supplemental simulation considering the effect of ASR damage by elasto-dynamic wave propagation using a finite integration technique method. It was found that the Hilbert Transform Indicator (HTI), developed for quantification of freeze/thaw damage in concrete structures, could also be successfully utilized for quantification of ASR damage. internal microstructure flaws, and reinforcement locations.

  8. Test results in the treatment of HTR reprocessing off-gas

    International Nuclear Information System (INIS)

    Barnert-Wiemer, H.; Bendick, B.; Juergens, B.; Nafissi, A.; Vygen, H.; Krill, W.

    1983-01-01

    The AKUT II-facility (throughput 10 m 3 /h, STP) for the clean up of the burner off-gas has been tested with synthetic off-gas and with off-gas from cold burner tests. The results are reported. During dissolution of the burner ash in nitric acid an off-gas is formed whose main component is air and which, besides the gaseous fission products, contains NO/sub x/. Before the separation of the gaseous fission products NO/sub x/ and/or O 2 are removed by reaction with H 2 or NH 3 . For these reactions catalysts were used. Because of the known disadvantages of catalytic systems, like reduction in efficiency by poisoning or thermal influence, the alternative method of thermal, flameless reduction was tested. The reactions were carried out in a stainless steel and a quartz reactor. Throughput, reaction temperature, O 2 -, NO/sub x/-, H 2 -, and NH 3 -concentrations respectively were varied. The goal of these tests was to remove O 2 and NO/sub x/ to below 1 ppM behind the reactor and NH 3 to below the detection limit of 50 ppM. It was found that at a reaction temperature of 750 0 C in the stainless steel reactor these goals can be reached for both H 2 and NH 3 as reducing agents. In the quartz reactor only the O 2 -H 2 -reaction takes place. Obviously stainless steel acts as a catalyst for all other reactions

  9. Hemorrhoids detected at colonoscopy: an infrequent cause of false-positive fecal immunochemical test results.

    NARCIS (Netherlands)

    Turenhout, S.T. van; Oort, F.A.; Terhaar sive Droste, J.S.; Coupe, V.M.; Hulst, R.W. van der; Loffeld, R.J.; Scholten, P.; Depla, A.C.; Bouman, A.A.; Meijer, G.A.; Mulder, C.J.; Rossum, L.G.M. van

    2012-01-01

    BACKGROUND: Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. OBJECTIVE: To determine the contribution of

  10. Mutagenicity in drug development: interpretation and significance of test results.

    Science.gov (United States)

    Clive, D

    1985-03-01

    The use of mutagenicity data has been proposed and widely accepted as a relatively fast and inexpensive means of predicting long-term risk to man (i.e., cancer in somatic cells, heritable mutations in germ cells). This view is based on the universal nature of the genetic material, the somatic mutation model of carcinogenesis, and a number of studies showing correlations between mutagenicity and carcinogenicity. An uncritical acceptance of this approach by some regulatory and industrial concerns is over-conservative, naive, and scientifically unjustifiable on a number of grounds: Human cancers are largely life-style related (e.g., cigarettes, diet, tanning). Mutagens (both natural and man-made) are far more prevalent in the environment than was originally assumed (e.g., the natural bases and nucleosides, protein pyrolysates, fluorescent lights, typewriter ribbon, red wine, diesel fuel exhausts, viruses, our own leukocytes). "False-positive" (relative to carcinogenicity) and "false-negative" mutagenicity results occur, often with rational explanations (e.g., high threshold, inappropriate metabolism, inadequate genetic endpoint), and thereby confound any straightforward interpretation of mutagenicity test results. Test battery composition affects both the proper identification of mutagens and, in many instances, the ability to make preliminary risk assessments. In vitro mutagenicity assays ignore whole animal protective mechanisms, may provide unphysiological metabolism, and may be either too sensitive (e.g., testing at orders-of-magnitude higher doses than can be ingested) or not sensitive enough (e.g., short-term treatments inadequately model chronic exposure in bioassay). Bacterial systems, particularly the Ames assay, cannot in principle detect chromosomal events which are involved in both carcinogenesis and germ line mutations in man. Some compounds induce only chromosomal events and little or no detectable single-gene events (e.g., acyclovir, caffeine

  11. Test results of CPT-deployed vertical electrode arrays at the DOE Hanford Site

    International Nuclear Information System (INIS)

    Narbutovskih, S.M.; Daily, W.; Ramirez, A.L.; Morey, R.M.

    1997-01-01

    Field studies were conducted at the DOE Hanford Site to test cone penetrometer installation of vertical electrode arrays (VEA) for use with Electrical Resistivity Tomography (ERT). Most VEA installation methods in current use are not economic for environmental applications. The cone penetrometer technology (CPT) can provide an economic and relatively non-intrusive installation method. However, a VEA with deployable and properly functioning electrodes was required. Results of the design, installation and testing of CPT VEAs are reported in this paper. Several designs were developed and bench tested for use with the CPT. After initial field installation studies, one design was chosen for further testing at the DOE Hanford Site. Four VEAs were each pushed to 100 feet in 4 days. To test the CPT VEAs, an infiltration experiment was conducted with cross VEA tomographic data collected for three vertical planes. These data were processed using the electrical resistivity tomography code developed by Lawrence Livermore National Laboratory (LLNL). Tomographic images for each vertical plane tracked the subsurface resistivity changes associated with the migrating fluid. It is concluded from these test results that the CPT is a viable method for installing VEAs. The VEAs were rapidly and economically installed to the maximum depth required, data of adequate quality were obtained and tomographic images from the infiltration experiment verified that the CPT VEAs provide viable ERT data

  12. Standard practice for analysis and interpretation of physics dosimetry results for test reactors

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This practice describes the methodology summarized in Annex Al to be used in the analysis and interpretation of physics-dosimetry results from test reactors. This practice relies on, and ties together, the application of several supporting ASTM standard practices, guides, and methods that are in various stages of completion (see Fig. 1). Support subject areas that are discussed include reactor physics calculations, dosimeter selection and analysis, exposure units, and neutron spectrum adjustment methods. This practice is directed towards the development and application of physics-dosimetrymetallurgical data obtained from test reactor irradiation experiments that are performed in support of the operation, licensing, and regulation of LWR nuclear power plants. It specifically addresses the physics-dosimetry aspects of the problem. Procedures related to the analysis, interpretation, and application of both test and power reactor physics-dosimetry-metallurgy results are addressed in Practice E 853, Practice E 560, Matrix E 706(IE), Practice E 185, Matrix E 706(IG), Guide E 900, and Method E 646

  13. Comparison of RPR 'teardrop' card test, VDRL and FTA-ABS tests results on sera from persons with suspected yaws in Columbia.

    Science.gov (United States)

    Hopkins, D R; Florez, D

    1977-08-01

    A small study comparing results of the rapid plasma reagin (RPR) teardrop card test performed in the field, with results of Venereal Disease Research Laboratory (VDRL) and fluorescent treponemal antibody absorption (FTA-ABS) tests performed in the laboratory on venous blood specimens from the same suspected yaws patients was undertaken in Columbia in July 1975. The results suggest that the RPR teardrop card test may be used to screen for infectious, or potentially infectious, yaws patients under field conditions, but that it will not reliably detect patients with VDRL titres of 1:2 or less, or all patients in whom sera are reactive in the FTA-ABS test.

  14. The Cherenkov correlated timing detector: beam test results from quartz and acrylic bars

    International Nuclear Information System (INIS)

    Kichimi, H.; Sugaya, Y.; Yamaguchi, H.; Yoshimura, Y.; Kanda, S.; Olsen, S.; Ueno, K.; Varner, G.; Bergfeld, T.; Bialek, J.; Lorenc, J.; Palmer, M.; Rudnick, G.; Selen, M.; Auran, T.; Boyer, V.; Honscheid, K.; Tamura, N.; Yoshimura, K.; Lu, C.; Marlow, D.; Mindas, C.; Prebys, E.; Asai, M.; Kimura, A.; Hayashi, S.

    1996-01-01

    Several prototypes of a Cherenkov correlated timing (CCT) detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype. (orig.)

  15. Preliminary results on performance testing of a turbocharged rotary combustion engine

    Science.gov (United States)

    Meng, P. R.; Rice, W. J.; Schock, H. J.; Pringle, D. P.

    1982-01-01

    The performance of a turbocharged rotary engine at power levels above 75 kW (100 hp) was studied. A twin rotor turbocharged Mazda engine was tested at speeds of 3000 to 6000 rpm and boost pressures to 7 psi. The NASA developed combustion diagnostic instrumentation was used to quantify indicated and pumping mean effect pressures, peak pressure, and face to face variability on a cycle by cycle basis. Results of this testing showed that a 5900 rpm a 36 percent increase in power was obtained by operating the engine in the turbocharged configuration. When operating with lean carburetor jets at 105 hp (78.3 kW) and 4000 rpm, a brake specific fuel consumption of 0.45 lbm/lb-hr was measured.

  16. Spent Fuel Drying System Test Results (Dry-Run in Preparation for Run 8)

    International Nuclear Information System (INIS)

    Oliver, B.M.; Klinger, G.S.; Abrefah, J.; Marschman, S.C.; MacFarlan, P.J.; Ritter, G.A.

    1999-01-01

    The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks in the basin have been detected and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site (WHC 1995). Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL)(a)on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of a test ''dry-run'' conducted prior to the eighth and last of those tests, which was conducted on an N-Reactor outer fuel element removed from K-West canister6513U. The system used for the dry-run test was the Whole Element Furnace Testing System, described in Section 2.0, located in the Postirradiation Testing Laboratory (PTL, 327 Building). The test conditions and methodologies are given in Section 3.0. The experimental results are provided in Section 4.0 and discussed Section 5.0

  17. Correlation of skin test results and specific immunoglobulin E blood levels with nasal provocation testing for house-dust mite allergies.

    Science.gov (United States)

    Haxel, Boris R; Huppertz, Tilman; Boessert, Patrick; Bast, Florian; Fruth, Kai

    2016-01-01

    Allergen-specific immunotherapy for house-dust mite (HDM) allergies is associated with lower success rates when compared with similar treatments for other inhalant allergens, such as grass or birch. One reason might be the greater difficulty in diagnosing patients with assumed HDM allergies because symptoms occur perennially and may differ from those of a conventional allergic rhinitis. The aim of the study was to compare the different methods of diagnosis in patients with assumed HDM allergy. We performed a retrospective analysis of nasal provocation tests (NPT) from patients (n = 161) evaluated for Dermatophagoides pteronyssinus (n = 127) and Dermatophagoides farinae (n = 104) allergies, and compared the results with other allergen testing methods (skin-prick test [SPT], intracutaneous test, and allergen specific immunoglobulin E levels [sIgE] to detect sensitization). Receiver operating characteristic curves were used for the analyses and the areas under the curve were calculated. For D. pteronyssinus and D. farinae, 86 and 70 complete data files, respectively, were available. For both tested HDMs, the results of the receiver operating characteristic curves showed a significant correlation for SPT and sIgE, with the results of the NPT (area under the curve, 0.742 to 0.763) but not for the intracutaneous test. In patients with a positive SPT (≥3 mm), an allergy was confirmed by the NPT in 69% of cases for D. pteronyssinus and 71% for D. farinae. A positive sIgE result (ImmunoCAP class of ≥2) was verified by the NPT in 69% of cases (D. pteronyssinus) and 70% (D. farinae). The predictability value for a positive NPT result is best for SPT and sIgE. Nevertheless, even if the results of both test systems are combined, the positive predictive value that was achieved was only 0.77 for D. pteronyssinus and 0.69 for D. farinae. Therefore, in patients eligible for immunotherapy for HDM, an NPT should be performed before the start of the therapy to verify a clinically

  18. Test results for cables used in nuclear power plants by a new environmental testing method

    International Nuclear Information System (INIS)

    Handa, Katsue; Fujimura, Shun-ichi; Hayashi, Toshiyasu; Takano, Keiji; Oya, Shingo

    1982-01-01

    In the nuclear power plants using PWRs or BWRs in Japan, environmental tests are provided, in which simulated LOCA conditions are considered so as to conform with Japanese conditions, and many cables which passed these tests are presently employed. Lately, the new environmental testing, in which a credible accident called MSLB (main steam line breakage) is taken into account, is investigated in PWR nuclear power plants, besides LOCA. This paper reports on the results of evaluating some PWR cables for this new environmental testing conditions. The several cables tested were selected out of PH cables (fire-retardant, ethylene propylene rubber insulated, chlorosulfonated polyethylene sheathed cables) as the cables for safety protecting circuits and to be used in containment vessels where the cables are to be exposed to severe environmental test conditions of 2 x 10 8 Rad γ-irradiation and simulated LOCA. All these cables have been accepted after the vertical tray burning test provided in the IEEE Standard 383. The new testing was carried out by sequentially applying thermal deterioration, γ-irradiation, and the exposure to steam (twice 300 s exposures to 190 deg C superheated steam). After completing each step, tensile strength, elongation, insulation resistance and breakdown voltage were measured, respectively. Every cable tested showed satisfactory breakdown voltage after the exposure to steam, thus it was decided to be acceptable. In future, it is required to investigate the influence of the rate of temperature rise on the cable to be tested in MSLB simulation. (Wakatsuki, Y.)

  19. Language lateralization by functional MRI : a comparison with wada test-preliminary results

    International Nuclear Information System (INIS)

    Ryoo, Jae Wook; Na, Dong Gyu; Byun, Hong Sik

    1999-01-01

    To evaluate the usefulness of functional MR imaging (fMRI) for the determination of language dominance and to assess differences in language lateralization according to activation task or activated area. Functional maps of the language area were obtained during word generation tasks(noun and verb) and a reading task in ten patients (9 right handed, 1 left handed) who had undergone the Wada test. MR examinations were performed using a 1.5T scanner and the EPI BOLD technique. The SPM program was employed for the postprocessing of images and the threshold for significance was set at p<0.001 or p<0.01. A lateralization index was calculated from the number of activated pixels in three hemispheric regions (whole hemisphere, frontal lobe, and temporoparietal lobe), and the results were compared with those of Wada tests. The results for lateralization of language area were compared among stimulation tasks and regions and used for calculation of lateralization indices. During the Wada test, nine patients were left dominant and one patient was right dominant for language. Language dominance based on activated signals in each hemisphere was consistent with the results of the Wada test in 87.5% (verb and noun generation tasks) and 90% (reading task) of patients. Language dominance determined by activated signals in the frontal lobe was consistent in 87.5%, 75%, and 80% of patients in each stimulation task (verb generation, noun generation, and reading), respectively. The consistency rate of activated signals in the temporoparietal lobe was 87.5%, 87.5% and 80% of patients in each task. the mean value of the lateralization index, calculated on the basis of activated signals in the temporoparietal lobe was higher than that in the hemisphere or frontal lobe. The verb generation task showed a higher lateralization index than the noun generation or reading task. The lateralization index was higher in the verb generation task and in the region of the temporoparietal lobe than in

  20. Language lateralization by functional MRI : a comparison with wada test-preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Ryoo, Jae Wook; Na, Dong Gyu; Byun, Hong Sik [Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)] (and others)

    1999-05-01

    To evaluate the usefulness of functional MR imaging (fMRI) for the determination of language dominance and to assess differences in language lateralization according to activation task or activated area. Functional maps of the language area were obtained during word generation tasks(noun and verb) and a reading task in ten patients (9 right handed, 1 left handed) who had undergone the Wada test. MR examinations were performed using a 1.5T scanner and the EPI BOLD technique. The SPM program was employed for the postprocessing of images and the threshold for significance was set at p<0.001 or p<0.01. A lateralization index was calculated from the number of activated pixels in three hemispheric regions (whole hemisphere, frontal lobe, and temporoparietal lobe), and the results were compared with those of Wada tests. The results for lateralization of language area were compared among stimulation tasks and regions and used for calculation of lateralization indices. During the Wada test, nine patients were left dominant and one patient was right dominant for language. Language dominance based on activated signals in each hemisphere was consistent with the results of the Wada test in 87.5% (verb and noun generation tasks) and 90% (reading task) of patients. Language dominance determined by activated signals in the frontal lobe was consistent in 87.5%, 75%, and 80% of patients in each stimulation task (verb generation, noun generation, and reading), respectively. The consistency rate of activated signals in the temporoparietal lobe was 87.5%, 87.5% and 80% of patients in each task. the mean value of the lateralization index, calculated on the basis of activated signals in the temporoparietal lobe was higher than that in the hemisphere or frontal lobe. The verb generation task showed a higher lateralization index than the noun generation or reading task. The lateralization index was higher in the verb generation task and in the region of the temporoparietal lobe than in