WorldWideScience

Sample records for test methods method

  1. Coal - testing methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-04-01

    This Standard specifies the method for the particle-size analysis, the method for determination of the float and sink characteristics, the method for determination of Hardgrove grindability indices, the method for determination of the crucible swelling number, the method for determination of the swelling properties, the method for determination of the fluidity properties, the method for determination of the coking properties, the method for determination of the fusibility of ash, and the method for determination of Roga indices of coal.

  2. Standard environmental test methods

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, D R

    1983-12-01

    This guide to uniformity in testing is intended primarily as an aid to persons responsible for designing, developing, and performing environmental tests. It will also be of use to those concerned with production, evaluation, and quality control and assurance. Checklists for preparing the environmental testing portion of product specifications are included, as are copies of Process Standards covering the instrumentation, equipment, and methods for use in environmental testing of Sandia National Laboratories components. Techniques and equipment are constantly improving. This version of SC-4452 reflects current state-of-the-art and practice in environmental testing. Previously existing sections of the document have ben updated and new ones have been added, e.g., Transient Testing on Vibration Machines.

  3. Evaluation of modal testing methods

    Science.gov (United States)

    Chen, J.-C.

    1984-01-01

    Modal tests are playing an increasingly important role in structural dynamics efforts which are in need of analytical model verification or trouble shootings. In the meantime, the existing modal testing methods are undergoing great changes as well as new methods are being created. Although devoted advocates of each method can be found to argue the relative advantages and disadvantages, the general superiority, if any, of one or the other is not yet evident. The Galileo spacecraft, a realistic, complex structural system, will be used as a test article for performing modal tests by various methods. The results will be used to evaluate the relative merits of the various modal testing methods.

  4. Aerial Refueling Test Methods

    Science.gov (United States)

    2015-04-13

    support of the AR Clearance Process. Covered topics include the ground and flight testing of boom/receptacle systems and probe/ drogue systems, test...REFUELING SYSTEMS ADVISORY GROUP 41-09-15 13 April 2015 v REFERENCES N° TITLE REFERENCE IS S U E DATE SOURCE 1. Probe and Drogue Aerial Refueling Data...Equipment: Probe- Drogue Interface Characteristics STANAG 3447 Ed 4 May ‘08 NATO AERIAL REFUELING SYSTEMS ADVISORY GROUP 41-09-15 13 April 2015 vi

  5. Methods for Equating Mental Tests.

    Science.gov (United States)

    1984-11-01

    1983) compared conventional and IRT methods for equating the Test of English as a Foreign Language ( TOEFL ) after chaining. Three conventional and...ID-A149 544 METHODS FOR ’EQUATING MENTAL TESTS (U) ASSESSMENT SYSTEMS 1/2 CORP ST PAUL MN K A GIRLLUCA ET AL. NOV 84 AFHRL-TR-84-35 F4i689-82-C-0023... TEST CHART NATIONAL BUREAU Of STANDARDS- 1963-A -I% AFHRL-TR-84-35 AIR FORCE 0, METHODS FOR EQUATING MENTAL TESTS H U By Kathleen A. Gialluca Leslie I

  6. [Inappropriate test methods in allergy].

    Science.gov (United States)

    Kleine-Tebbe, J; Herold, D A

    2010-11-01

    Inappropriate test methods are increasingly utilized to diagnose allergy. They fall into two categories: I. Tests with obscure theoretical basis, missing validity and lacking reproducibility, such as bioresonance, electroacupuncture, applied kinesiology and the ALCAT-test. These methods lack both the technical and clinical validation needed to justify their use. II. Tests with real data, but misleading interpretation: Detection of IgG or IgG4-antibodies or lymphocyte proliferation tests to foods do not allow to separate healthy from diseased subjects, neither in case of food intolerance, allergy or other diagnoses. The absence of diagnostic specificity induces many false positive findings in healthy subjects. As a result unjustified diets might limit quality of life and lead to malnutrition. Proliferation of lymphocytes in response to foods can show elevated rates in patients with allergies. These values do not allow individual diagnosis of hypersensitivity due to their broad variation. Successful internet marketing, infiltration of academic programs and superficial reporting by the media promote the popularity of unqualified diagnostic tests; also in allergy. Therefore, critical observation and quick analysis of and clear comments to unqualified methods by the scientific medical societies are more important than ever.

  7. Test equating methods and practices

    CERN Document Server

    Kolen, Michael J

    1995-01-01

    In recent years, many researchers in the psychology and statistical communities have paid increasing attention to test equating as issues of using multiple test forms have arisen and in response to criticisms of traditional testing techniques This book provides a practically oriented introduction to test equating which both discusses the most frequently used equating methodologies and covers many of the practical issues involved The main themes are - the purpose of equating - distinguishing between equating and related methodologies - the importance of test equating to test development and quality control - the differences between equating properties, equating designs, and equating methods - equating error, and the underlying statistical assumptions for equating The authors are acknowledged experts in the field, and the book is based on numerous courses and seminars they have presented As a result, educators, psychometricians, professionals in measurement, statisticians, and students coming to the subject for...

  8. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  9. Electrokinetic remediation prefield test methods

    Science.gov (United States)

    Hodko, Dalibor (Inventor)

    2000-01-01

    Methods for determining the parameters critical in designing an electrokinetic soil remediation process including electrode well spacing, operating current/voltage, electroosmotic flow rate, electrode well wall design, and amount of buffering or neutralizing solution needed in the electrode wells at operating conditions are disclosed These methods are preferably performed prior to initiating a full scale electrokinetic remediation process in order to obtain efficient remediation of the contaminants.

  10. Method

    Directory of Open Access Journals (Sweden)

    Ling Fiona W.M.

    2017-01-01

    Full Text Available Rapid prototyping of microchannel gain lots of attention from researchers along with the rapid development of microfluidic technology. The conventional methods carried few disadvantages such as high cost, time consuming, required high operating pressure and temperature and involve expertise in operating the equipment. In this work, new method adapting xurography method is introduced to replace the conventional method of fabrication of microchannels. The novelty in this study is replacing the adhesion film with clear plastic film which was used to cut the design of the microchannel as the material is more suitable for fabricating more complex microchannel design. The microchannel was then mold using polymethyldisiloxane (PDMS and bonded with a clean glass to produce a close microchannel. The microchannel produced had a clean edge indicating good master mold was produced using the cutting plotter and the bonding between the PDMS and glass was good where no leakage was observed. The materials used in this method is cheap and the total time consumed is less than 5 hours where this method is suitable for rapid prototyping of microchannel.

  11. Method

    Directory of Open Access Journals (Sweden)

    Andrey Gnatov

    2015-01-01

    Full Text Available Recently repair and recovery vehicle body operations become more and more popular. A special place here is taken by equipment that provides performance of given repair operations. The most interesting things are methods for recovery of car body panels that allow the straightening without disassembling of car body panels and damaging of existing protective coating. Now, there are several technologies for repair and recovery of car body panels without their disassembly and dismantling. The most perspective is magnetic-pulse technology of external noncontact straightening. Basics of magnetic-pulse attraction, both ferromagnetic and nonferromagnetic thin-walled sheet metal, are explored. Inductor system calculation models of magnetic-pulse straightening tools are presented. Final analytical expressions for excited efforts calculation in the tools under consideration are introduced. According to the obtained analytical expressions, numerical evaluations of excited forces were executed. The volumetric epures of the attractive force radial distributions for different types of inductors were built. The practical testing of magnetic-pulse straightening with research tools is given. Using the results of the calculations we can create effective tools for an external magnetic-pulse straightening of car body panels.

  12. method

    Directory of Open Access Journals (Sweden)

    L. M. Kimball

    2002-01-01

    Full Text Available This paper presents an interior point algorithm to solve the multiperiod hydrothermal economic dispatch (HTED. The multiperiod HTED is a large scale nonlinear programming problem. Various optimization methods have been applied to the multiperiod HTED, but most neglect important network characteristics or require decomposition into thermal and hydro subproblems. The algorithm described here exploits the special bordered block diagonal structure and sparsity of the Newton system for the first order necessary conditions to result in a fast efficient algorithm that can account for all network aspects. Applying this new algorithm challenges a conventional method for the use of available hydro resources known as the peak shaving heuristic.

  13. Hazardous Waste Test Methods / SW-846

    Science.gov (United States)

    The Resource Conservation and Recovery Act Test Methods for Evaluating Solid Waste: Physical/Chemical Methods (SW-846) provide guidance to analytical scientists, enforcement officers and method developers across a variety of sectors.

  14. Automatic Testing with Formal Methods

    NARCIS (Netherlands)

    Tretmans, G.J.; Belinfante, Axel

    1999-01-01

    The use of formal system specifications makes it possible to automate the derivation of test cases from specifications. This allows to automate the whole testing process, not only the test execution part of it. This paper presents the state of the art and future perspectives in testing based on

  15. The WST method, a fracture mechanics test method for FRC

    DEFF Research Database (Denmark)

    Lofgren, I.; Stang, Henrik; Olesen, John Forbes

    2008-01-01

    The applicability of the wedge-splitting test method (WST), for determining fracture properties of fibre-reinforced concrete, is discussed. Experimental results, using the WST method, are compared with results from uniaxial tension tests (UTT) and three-point bending tests (3PBT) for five different......-crack opening (sigma-w) relationships have been determined for each mix and test method. For the two WST specimen sizes, there is no apparent difference either in the number of fibres (per cm(2)) crossing the fracture plane or in the fracture properties. The major factor contributing to the scatter in the test...... results is believed to be related to the variation in the number of fibres across the fracture plane. Furthermore, the inverse analyses indicate no systematic differences in the determined parameters between two WST specimens or between the WST and the 3PBT....

  16. Telemetry test methods. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bowers, J.L.; Bullard, D.L.; Schelp, T.R.

    1978-04-01

    A flexible test system is studied and proposed to provide an extensive evaluation and testing capability for telemetry products. A distributed computer controlled, modular unit test system using Computer Automated Measurement and Control (CAMAC) standard hardware and compatible software is selected because of its flexibility of application and long term cost effectiveness.

  17. Development of Dissolution Test Method for Drotaverine ...

    African Journals Online (AJOL)

    Methods: Sink conditions, drug stability and specificity in different dissolution media were tested to optimize a dissolution test method using a USP paddle type dissolution test apparatus set at a speed of. 50 rpm. The dissolution medium consisted of 900 ml of phosphate buffer (pH 6.8) containing 0.25% w/v cetrimide at 37 ...

  18. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  19. Test Methods for Robot Agility in Manufacturing.

    Science.gov (United States)

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2016-01-01

    The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.

  20. Automated Test Methods for XML Metadata

    Science.gov (United States)

    2017-12-28

    defines artifacts and system configurations essential to the collection and management of telemetry data. The RCC has established standards for...Method for Testing Syntax The test method is as follows. 1. Initialize the programming environment. 2. Write test application code to use the...engine. o At the time of this writing , a recommended encoding of these rules does not exist. o Encodings shall be selected that can be interpreted by

  1. Method and apparatus for testing microfilaments

    Science.gov (United States)

    Schleitweiler, Patrick M.; Merten, Jr., Charles W.

    1995-08-01

    A method and apparatus are disclosed for testing tensile strength of microfilaments. Fibers as small as 0.001 inch in diameter and 0.04 inches in length have been tested, although the method and apparatus of the invention are capable of testing fibers of smaller diameter and length. The invention utilizes a method wherein one or both ends of a microfilament is gripped using resin which is softened sufficiently to accept an end of the microfilament and then allowed to harden. The invention also employs the use of a translation stage capable of controlled three-dimensional movement suited to facilitating gripping of the microfilament.

  2. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  3. Test Methods for Effects on Organisms

    DEFF Research Database (Denmark)

    Krogh, P. H.

    1997-01-01

    NORD-UTTE er Nordisk koordineringsgrupp för utvekling av testmetoder inom toxicologi och ekotoxicology. The Nordic Co-ordination Group for the Development of Test Methods for Toxicology and Ecotoxicology...

  4. Absorbing Software Testing into the Scrum Method

    Science.gov (United States)

    Tuomikoski, Janne; Tervonen, Ilkka

    In this paper we study, how to absorb software testing into the Scrum method. We conducted the research as an action research during the years 2007-2008 with three iterations. The result showed that testing can and even should be absorbed to the Scrum method. The testing team was merged into the Scrum teams. The teams can now deliver better working software in a shorter time, because testing keeps track of the progress of the development. Also the team spirit is higher, because the Scrum team members are committed to the same goal. The biggest change from test manager’s point of view was the organized Product Owner Team. Test manager don’t have testing team anymore, and in the future all the testing tasks have to be assigned through the Product Backlog.

  5. MODERN METHODS OF FOOD INTOLERANCE TESTING

    Directory of Open Access Journals (Sweden)

    M. Yu. Rosensteyn

    2016-01-01

    Full Text Available Аn analytical review of modern methods of food intolerance diagnostics based on interpretation of markers used in the various tests is рresented. It is shown that tests based on observation of the reaction of specific antibodies of the immune system to food antigens tested, are the most accurate, reliable and representative for the diagnosis of food intolerance.

  6. Development of test methods for textile composites

    Science.gov (United States)

    Masters, John E.; Ifju, Peter G.; Fedro, Mark J.

    1993-01-01

    NASA's Advanced Composite Technology (ACT) Program was initiated in 1990 with the purpose of developing less costly composite aircraft structures. A number of innovative materials and processes were evaluated as a part of this effort. Chief among them are composite materials reinforced with textile preforms. These new forms of composite materials bring with them potential testing problems. Methods currently in practice were developed over the years for composite materials made from prepreg tape or simple 2-D woven fabrics. A wide variety of 2-D and 3-D braided, woven, stitched, and knit preforms were suggested for application in the ACT program. The applicability of existing test methods to the wide range of emerging materials bears investigation. The overriding concern is that the values measured are accurate representations of the true material response. The ultimate objective of this work is to establish a set of test methods to evaluate the textile composites developed for the ACT Program.

  7. Alternative Test Methods for Developmental Neurotoxicity: A ...

    Science.gov (United States)

    Exposure to environmental contaminants is well documented to adversely impact the development of the nervous system. However, the time, animal and resource intensive EPA and OECD testing guideline methods for developmental neurotoxicity (DNT) are not a viable solution to characterizing potential chemical hazards for the thousands of untested chemicals currently in commerce. Thus, research efforts over the past decade have endeavored to develop cost-effective alternative DNT testing methods. These efforts have begun to generate data that can inform regulatory decisions. Yet there are major challenges to both the acceptance and use of this data. Major scientific challenges for DNT include development of new methods and models that are “fit for purpose”, development of a decision-use framework, and regulatory acceptance of the methods. It is critical to understand that use of data from these methods will be driven mainly by the regulatory problems being addressed. Some problems may be addressed with limited datasets, while others may require data for large numbers of chemicals, or require the development and use of new biological and computational models. For example mechanistic information derived from in vitro DNT assays can be used to inform weight of evidence (WoE) or integrated approaches to testing and assessment (IATA) approaches for chemical-specific assessments. Alternatively, in vitro data can be used to prioritize (for further testing) the thousands

  8. Alternative Test Methods for Electronic Parts

    Science.gov (United States)

    Plante, Jeannette

    2004-01-01

    It is common practice within NASA to test electronic parts at the manufacturing lot level to demonstrate, statistically, that parts from the lot tested will not fail in service using generic application conditions. The test methods and the generic application conditions used have been developed over the years through cooperation between NASA, DoD, and industry in order to establish a common set of standard practices. These common practices, found in MIL-STD-883, MIL-STD-750, military part specifications, EEE-INST-002, and other guidelines are preferred because they are considered to be effective and repeatable and their results are usually straightforward to interpret. These practices can sometimes be unavailable to some NASA projects due to special application conditions that must be addressed, such as schedule constraints, cost constraints, logistical constraints, or advances in the technology that make the historical standards an inappropriate choice for establishing part performance and reliability. Alternate methods have begun to emerge and to be used by NASA programs to test parts individually or as part of a system, especially when standard lot tests cannot be applied. Four alternate screening methods will be discussed in this paper: Highly accelerated life test (HALT), forward voltage drop tests for evaluating wire-bond integrity, burn-in options during or after highly accelerated stress test (HAST), and board-level qualification.

  9. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  10. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  11. Implementation of New Test Methods into Practical Testing.

    Science.gov (United States)

    Curren, Rodger D; Poth, Albrecht; Raabe, Hans A

    New toxicology test methods, especially those using in vitro methods, are continually being developed. Some are used by industry for screening purposes; others are eventually validated for regulatory use. However, for a new test method to be firmly adopted by industry it must be readily available, generally through an in-house industry laboratory, an academic laboratory, or a contract research organization. Regardless of the type of laboratory which intends to implement the test method, certain steps must be taken to ascertain that the method that is put into place is reproducible and performs identically to the test method that was published or has undergone validation. This involves developing protocols and standard operating procedures, training staff, developing historic positive and negative control data, establishing acceptable performance with proficiency chemicals, and addressing all the safety concerns that may accompany the assay. From experience within a contract research laboratory, we provide guidance on how to most efficiently accomplish these tasks.

  12. Efficiency Test Method for Electric Vehicle Chargers

    DEFF Research Database (Denmark)

    Kieldsen, Andreas; Thingvad, Andreas; Martinenas, Sergejus

    2016-01-01

    This paper investigates different methods for measuring the charger efficiency of mass produced electric vehicles (EVs), in order to compare the different models. The consumers have low attention to the loss in the charger though the impact on the driving cost is high. It is not a high priority...... different vehicles. A unified method for testing the efficiency of the charger in EVs, without direct access to the component, is presented. The method is validated through extensive tests of the models Renault Zoe, Nissan LEAF and Peugeot iOn. The results show a loss between 15 % and 40 %, which is far...... above the state of the art power converters. This is an unnecessary high consumption of electrical energy during charging, which not only affects the consumer financially, but also creates unnecessary load on the grid....

  13. Validation of qualitative microbiological test methods

    NARCIS (Netherlands)

    IJzerman-Boon, Pieta C.; van den Heuvel, Edwin R.

    2015-01-01

    This paper considers a statistical model for the detection mechanism of qualitative microbiological test methods with a parameter for the detection proportion (the probability to detect a single organism) and a parameter for the false positive rate. It is demonstrated that the detection proportion

  14. Assessment of resampling methods for causality testing

    NARCIS (Netherlands)

    Papana, A.; Kyrtsou, C.; Kugiumtzis, D.; Diks, C.

    2014-01-01

    Different resampling methods for the null hypothesis of non-causality are assessed. As test statistic the partial transfer entropy (PTE), an information and model-free measure, is used. Two resampling techniques,1) the time shifted surrogates and 2) the stationary bootstrap, are combined with the

  15. Equated Pooled Booklet Method in DIF Testing

    Science.gov (United States)

    Cheng, Ying; Chen, Peihua; Qian, Jiahe; Chang, Hua-Hua

    2013-01-01

    Differential item functioning (DIF) analysis is an important step in the data analysis of large-scale testing programs. Nowadays, many such programs endorse matrix sampling designs to reduce the load on examinees, such as the balanced incomplete block (BIB) design. These designs pose challenges to the traditional DIF analysis methods. For example,…

  16. Characterization methods for ultrasonic test systems

    Energy Technology Data Exchange (ETDEWEB)

    Busse, L.J.; Becker, F.L.; Bowey, R.E.; Doctor, S.R.; Gribble, R.P.; Posakony, G.J.

    1982-07-01

    Methods for the characterization of ultrasonic transducers (search units) and instruments are presented. The instrument system is considered as three separate components consisting of a transducer, a receiver-display, and a pulser. The operation of each component is assessed independently. The methods presented were chosen because they provide the greatest amount of information about component operation and were not chosen based upon such conditions as cost, ease of operation, field implementation, etc. The results of evaluating a number of commercially available ultrasonic test instruments are presented.

  17. Thermal insulation testing method and apparatus

    Science.gov (United States)

    Fesmire, James E. (Inventor); Augustynowicz, Stanislaw D. (Inventor)

    2004-01-01

    A test apparatus and method of its use for evaluating various performance aspects of a test specimen is disclosed. A chamber within a housing contains a cold mass tank with a contact surface in contact with a first surface of a test specimen. The first surface of the test specimen is spaced from the second surface of the test specimen by a thickness. The second surface of the test specimen is maintained at a desired warm temperature. The first surface is maintained at a constant temperature by a liquid disposed within the cold mass tank. A boil-off flow rate of the gas is monitored and provided to a processor along with the temperature of the first and second surfaces of the test specimen. The processor calculates thermal insulation values of the test specimen including comparative values for heat flux and apparent thermal conductivity (k-value). The test specimen may be placed in any vacuum pressure level ranging from about 0.01 millitorr to 1,000,000 millitorr with different residual gases as desired. The test specimen may be placed under a mechanical load with the cold mass tank and another factors may be imposed upon the test specimen so as to simulate the actual use conditions.

  18. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  19. New Graphical Methods and Test Statistics for Testing Composite Normality

    Directory of Open Access Journals (Sweden)

    Marc S. Paolella

    2015-07-01

    Full Text Available Several graphical methods for testing univariate composite normality from an i.i.d. sample are presented. They are endowed with correct simultaneous error bounds and yield size-correct tests. As all are based on the empirical CDF, they are also consistent for all alternatives. For one test, called the modified stabilized probability test, or MSP, a highly simplified computational method is derived, which delivers the test statistic and also a highly accurate p-value approximation, essentially instantaneously. The MSP test is demonstrated to have higher power against asymmetric alternatives than the well-known and powerful Jarque-Bera test. A further size-correct test, based on combining two test statistics, is shown to have yet higher power. The methodology employed is fully general and can be applied to any i.i.d. univariate continuous distribution setting.

  20. 2-d Simulations of Test Methods

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2004-01-01

    using both a Newton and Bingham model for characterisation of the rheological properties of the concrete. From the results, it is expected that both the slump flow and L-box can be simulated quite accurately when the model is extended to 3-d and the concrete is characterised according to the Bingham......One of the main obstacles for the further development of self-compacting concrete is to relate the fresh concrete properties to the form filling ability. Therefore, simulation of the form filling ability will provide a powerful tool in obtaining this goal. In this paper, a continuum mechanical...... approach is presented by showing initial results from 2-d simulations of the empirical test methods slump flow and L-box. This method assumes a homogeneous material, which is expected to correspond to particle suspensions e.g. concrete, when it remains stable. The simulations have been carried out when...

  1. SAS molecular tests Salmonella detection kit. Performance tested method 021202.

    Science.gov (United States)

    Bapanpally, Chandra; Montier, Laura; Khan, Shah; Kasra, Akif; Brunelle, Sharon L

    2014-01-01

    The SAS Molecular tests Salmonella Detection method, a Loop-mediated Isothermal Amplification method, performed as well as or better than the U.S. Department of Agriculture-Food Safety Inspection Service Microbiology Laboratory Guidebook and the U.S. Food and Drug Administration Bacteriological Analytical Manual reference methods for ground beef, beef trim, ground turkey, chicken carcass rinses, bagged mixed lettuce, and fresh spinach. The ground beef (30% fat, 25 g test portion), poultry matrixes and leafy greens were validated in a 6-7 h enrichment, and ground beef (30% fat, 375 g composite test portion) and beef trim (375 g composite test portion) were validated in a 16-20 h enrichment. The method performance for meat and leafy green matrixes was shown to be acceptable under conditions of co-enrichment with Escherichia coli 0157. Thus, after a short 6-7 h co-enrichment step, ground beef, beef trim, lettuce, and spinach can be tested for both Salmonella and E. coli O157. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 100 Salmonella serovars and 30 non-Salmonella species examined. The method was shown to be robust when enrichment time, DNA extract hold time, and DNA volume were varied.

  2. Standardization for Large Deflection Rotating-bending Fatigue Testing Method

    National Research Council Canada - National Science Library

    Reseach Committee on Standardizatio

    1996-01-01

    ... testing method has not been established. Consideing these background, actural problems of the conventional method were investigated, and load-controlled method and deflection-controlled method were tested in order to compare the scattering...

  3. Improved grindability test: essential refinements to method

    Energy Technology Data Exchange (ETDEWEB)

    Dick Sanders [QCC Resources (Australia)

    2007-01-15

    Under Project C12063 a test was developed and demonstrated which overcame all of the deficiencies of the Standard Hardgrove Grindability Index (HGI) Test. It used a standard volume of a representative 'by zero' sample, and expressed the results of the standard grind in terms of the Sauter mean diameter, SMD (in {mu}m). The test was named the Improved Grindability Test (IGT). In Project C13065 a steady state IGT was developed. A modification to the method was needed to overcome the effect of prior breakage and this was the basis for this project. Six coals of widely varying type were sampled at exposed coal faces i.e. with no prior breakage history. These were dropped repeatedly, crushed to pass 50 mm, and divided into A and B streams. A was 'gently' crushed to pass 8 mm (jaw crusher), while B was 'vigorously' crushed to pass 8 mm. Each -8 mm sample was then crushed to pass 2 mm by passing about ten times through a plate mill with progressively closer settings. The results have shown that the effects of prior breakage history can be substantially minimised, although not completely eliminated (especially for the softest coals), by increasing the starting sample top size from 4.75 to 8 mm and crushing all of the sample each time, for a large number of passes, to the 2 mm top size for the IGT test. Testing outcomes, and the interpretation of results, have been significantly compromised by sample losses during preparation and testing. Precision at a given laboratory seems acceptable, although agreement between laboratories is disappointing. The Steady State version of the IGT shows great promise, with the mass% of -75 {mu}m produced by grinding, under 'steady state' conditions (5 minutes) being a useful indicator of a coal's grindability.

  4. Methods of Testing Thermal Insulation and Associated Test Apparatus

    Science.gov (United States)

    2004-01-01

    The system and method for testing thermal insulation uses a cryostatic insulation tester having a vacuum chamber and a cold mass including a test chamber and upper and lower guard chambers adjacent thereto. The thermal insulation is positioned within the vacuum chamber and adjacent the cold mass. Cryogenic liquid is supplied to the test chamber, upper guard and lower guard to create a first gas layer in an upper portion of the lower guard chamber and a second gas layer in an upper portion of the test chamber. Temperature are sensed within the vacuum chamber to test the thermal insulation.

  5. CHROMagar Salmonella Detection Test Kit. Performance Tested Method 020502.

    Science.gov (United States)

    Webb, Katana; Ritter, Vicki

    2009-01-01

    BBL CHROMagar Salmonella was evaluated by an external food testing laboratory for the recovery of Salmonella in peanut butter using the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) procedure. The peanut butter was found to be negative for the presence of Salmonella and, therefore, was seeded with heat-stressed Salmonella at target concentrations of 0.2 and 2 CFU/25 g. The Salmonella-seeded samples remained at room temperature for 14 days before analysis to stabilize the Salmonella in the food environment. Twenty 25 g test portions from each seeded level and five 25 g samples of uninoculated control samples were processed using enrichment broths as outlined in the FDA-BAM procedure. BBL CHROMagar Salmonella-prepared plates were evaluated with the FDA reference method media (bismuth sulfite, xylose lysine desoxycholate, and Hektoen enteric agars). Fractionally positive results were obtained from the lower inoculum level of peanut butter samples. Five positive cultures were recovered from both the BBL CHROMagar Salmonella and reference methods. The two methods gave identical results for all cultures resulting in a method agreement of 100%. McNemar's chi2 test, which assesses the evidence for difference in marginal proportions between two methods, could not be evaluated because it requires one or more discrepant cultures. However, because there were no discrepant cultures, the marginal proportions for the two methods were identical; therefore, there is no evidence of a difference between the methods. This study demonstrates that the results from BBL CHROMagar Salmonella are comparable to the three reference method media for the detection of Salmonella in peanut butter using the FDA-BAM procedures.

  6. Seismic methods for verifying nuclear test bans

    Science.gov (United States)

    Sykes, Lynn R.; Evernden, Jack F.; Cifuentes, Inés

    1983-10-01

    Seismological research of the past 25 years related to verification of a Threshold Test Ban Treaty (TIBT) indicates that a treaty banning nuclear weapons tests in all environments, including underground explosions, can be monitored with high reliablility down to explosions of very small size (about one kiloton). There would be high probability of successful identification of explosions of that size even if elaborate measures were taken to evade detection. Seismology provides the principal means of detecting, locating and identifying underground explosions and of determining their yields. We discuss a number of methods for identifying detected seismic events as being either explosions or earthquakes including the event's location, depth and spectral character. The seismic waves generated by these two types of sources differ in a number of fundamental ways that can be utilized for identification or discrimination. All of the long-standing issues related to a comprehensive treaty were resolved in principle (and in may cases in detail) in negotiations between the U.S., the U.S.S.R. and Britian from 1977 to 1980. Those negotiations have not resumed since 1980. Inadequate seismic means of verifying a CTBT, Soviet cheating on the 150-kt limit of the Treshold Test Ban Treaty of 1976, and the need to develop and test new nuclear weapons were cited in 1982 by the U.S. government as reasons for not continuing negotiations for a CTBT. The first two reservations, which depend heavily on seismological information, are not supported scientifically. A CTBT could help to put a lid on the seemingly endless testing of new generations of nuclear weapons by both superpowers.

  7. 40 CFR 63.1546 - Test methods.

    Science.gov (United States)

    2010-07-01

    ...) Method 3 shall be used for gas analysis. (iv) Method 4 shall be used to determine moisture content of the... accordance with paragraph (a)(2)(iv) of this section, divided by the total plant operating time, in hours... position during normal operation. (4) Do not determine doorway in-draft when ambient wind speed exceeds 2...

  8. Fracture mechanics life analytical methods verification testing

    Science.gov (United States)

    Favenesi, J. A.; Clemons, T. G.; Riddell, W. T.; Ingraffea, A. R.; Wawrzynek, P. A.

    1994-01-01

    The objective was to evaluate NASCRAC (trademark) version 2.0, a second generation fracture analysis code, for verification and validity. NASCRAC was evaluated using a combination of comparisons to the literature, closed-form solutions, numerical analyses, and tests. Several limitations and minor errors were detected. Additionally, a number of major flaws were discovered. These major flaws were generally due to application of a specific method or theory, not due to programming logic. Results are presented for the following program capabilities: K versus a, J versus a, crack opening area, life calculation due to fatigue crack growth, tolerable crack size, proof test logic, tearing instability, creep crack growth, crack transitioning, crack retardation due to overloads, and elastic-plastic stress redistribution. It is concluded that the code is an acceptable fracture tool for K solutions of simplified geometries, for a limited number of J and crack opening area solutions, and for fatigue crack propagation with the Paris equation and constant amplitude loads when the Paris equation is applicable.

  9. Powder Flow Testing: Judicious Choice of Test Methods.

    Science.gov (United States)

    Tay, Justin Yong Soon; Liew, Celine Valeria; Heng, Paul Wan Sia

    2017-07-01

    Flow property of pharmaceutical powders can be assessed by various flow testers and test methods. In this study, eight commercially available lactose grades were sourced and tested for angles of repose, tapping studies, shear cell measurements, stirred powder rheometry, and avalanching powder measurements. The relationships between various flow parameters and particle size were analyzed. Deviations from the general trend could be attributed to either the insensitivity of the test or differences in particle shape. The basic flowability energy of the powder rheometer was unable to reconcile the effects of shape and particle size on powder flowability. Avalanche time of the revolving drum powder analyzer and angle of repose exhibited good correlation with each other (r = 0.92) but experienced poor resolution for samples of smaller particle sizes due to powder cohesiveness and the propensity for agglomerative flow. Flow test parameters could be categorized into three broad types, based on their relationship with particle size: (i) linear relationship, (ii) test parameter more sensitive to smaller sized particles, and (iii) test parameter more sensitive to larger sized particles. Choice of test parameters used to represent powder flow should be dependent on the sensitivity of the selected flow test methods to the sample types.

  10. [Evaluation of variable methods for HPV testing].

    Science.gov (United States)

    Cheng, Jiao-ying; Bian, Mei-lu; Ma, Li; Cong, Xiao; Chen, Ying; Liu, Jun

    2013-08-01

    To evaluate clinical efficacy of different HPV methods in screening of cervical cancers. Between August 2011 and November 2011, 424 women in the China-Japan Friendship Hospital were enrolled in this study. All participants were undergone liquid-based cytology test (LCT), Hybrid capture II (HC-II) and real-time (RT) PCR high risk HPV DNA test for HPV16 and HPV18 genotyping. Those results were classified into two group: 424 women at HC-II group with LCT and HC-II test and 421 women at PCR group with LCT and PCR test. All women with atypical squamous cell of undetermined significance (ASCUS) or above in cytological result with high risk HPV positive at two group underwent cervical biopsy by colposcopy.In the mean time, women with negative in cytological results and with HPV 16 and(or) HPV 18 positive also underwent histo-pathological examination by and colposcopy. The results in two groups were discussed:LCT+HC-II group (424 patients) and LCT+PCR12+2 group (421 patients). (1) There was no significant difference in cervical intraepithelial neoplasia (CIN) II or above disease between LCT+HC-II group and LCT+PCR12+2 group (χ(2) = 3.35, P > 0.05).Sensitivity, specificity, positive predictive value and negative predictive value for detection of CINII or above using HC-II and PCR12+2 were 77.8%, 79.4%, 20.4%, 98.1% and 96.3%, 78.2%, 23.2%, 99.7%, respectively. (2) In LCT+PCR12+2 group, it was found 34 women with HPV16 positive, 5 women with HPV 18 positive including 1 women combined with HPV 16 positive, 74 women with other high risk HPV positive and 309 women with HPV negative. Compared to the infection of other high-risk HPV types, HPV 16 and HPV 18 infection leads to a higher chance of cervical lesions with CIN II or above [51.3% (20/39) and 8.1% (6/74) ]. (3) A significant difference of causing cervical cancer and CINII or above was found among women who were infected with HPV 16 and/or HPV 18 infection, with other high-risk HPV types and negative in high-risk HPV

  11. 40 CFR 63.1161 - Performance testing and test methods.

    Science.gov (United States)

    2010-07-01

    ... exception that no traverse point shall be within one inch of the stack or duct wall; (ii) Method 2, to... stack gas; (iv) Method 4, to determine the moisture content of the stack gas; and (v) Method 26A, “Determination of Hydrogen Halide and Halogen Emissions from Stationary Sources—Isokinetic Method,” to determine...

  12. testing a consensus conference method by discussing

    African Journals Online (AJOL)

    hi-tech

    2000-10-10

    Oct 10, 2000 ... controversial subjects(1-3). Consensus conference methods were developed by the ... Selection of the topic: The current topic was selected after observing the treatment modalities of traumatic dental injuries ... require improvement. The topic was considered appropriate and of potential importance to dental ...

  13. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  14. Functional Element Test Tool and Method

    Science.gov (United States)

    2001-07-03

    functional element 6 involved in the run test case step 8 6 of a test. SAFE test tool 7 10 preferably operates in several selectable modes of...options 9 (e.g., data initiation buttons) are displayed as dictated by 10 each test case. The run test case step 86 is then performed 11 under...19 object functional element being tested during run test case step 20 8 6 would be maintained via SAFE test tool 10 for later 21 comparison or

  15. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  16. On sine dwell or broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung; Wada, Ben K.

    1987-01-01

    For large, complex spacecraft structural systems, the objectives of the modal test are outlined. Based on these objectives, the comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantages or disadvantages of each method are examined. The usefulness or shortcoming of the methods are given from a practicing engineer's view point.

  17. Comparison of sine dwell and broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung

    1989-01-01

    The objectives of modal tests for large complex spacecraft structural systems are outlined. The comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods, are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantage or disadvantage of each method is examined. The usefulness or shortcomings of the methods are given from a practical engineering viewpoint.

  18. [Testing aphasia by psychometric methods (author's transl)].

    Science.gov (United States)

    Lang, C

    1981-04-01

    In a survey of psychometric tests in world-wide use for the examination of aphasia stress is laid on methodological points. Separately for individual tests and tests and test batteries the development and clinical application are delineated, statistical criteria mentioned and diagnostic usefulness evaluated.

  19. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Peeters, B.

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stocha......In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method...

  20. Generation of test databases using sampling methods

    OpenAIRE

    Buda, Teodora Sandra

    2013-01-01

    peer-reviewed Populating the testing environment with relevant data represents a great challenge in software validation, generally requiring expert knowledge about the system under development, as its data critically impacts the outcome of the tests designed to assess the system. Current practices of populating the testing environments generally focus on developing e cient algorithms for generating synthetic data or use the production environment for testing purposes. ...

  1. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Peeters, B.; Hermans, L.

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stocha......In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method......, the stochastic subspace method for estimation of state space systems and the prediction error method for estimation of Auto-Regressive Moving Average Vector models. It is not the entention to elect a winner among the four methods, but more to emphasize the different advantages of each of the methods....

  2. Correlations among bending test methods for dental hard resins.

    Science.gov (United States)

    Miura, Daisuke; Miyasaka, Taira; Aoki, Harumi; Aoyagi, Yusuke; Ishida, Yoshiki

    2017-07-26

    Three types of bending tests -the 3-point bending test, 4-point bending test and biaxial flexural test- were performed to examine the correlations among the testing methods for dental hard resins (HRs). The results for 5 HRs showed that the bending strengths in descending order were: biaxial flexural strength>3-point bending strength>4-point bending strength. Regression analysis of the test methods indicated that the coefficients of determination were large for all test methods; the largest was for the combination of the 4-point bending test and biaxial flexural tests. The Weibull moduli ranged from 5.42 to 10.61, and a similar descending-order trend was found in the Weibull characteristic strength (S0) of the test methods. The biaxial flexural test method is thus a valid test of the flexural strength of dental hard resins.

  3. Comparison of System Identification Methods using Ambient Bridge Test Data

    OpenAIRE

    Andersen, P; Brincker, Rune; Peeters, B; De Roeck, G.; Hermans, L.; Krämer, C.

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stochastic subspace method for estimation of state space systems and the prediction error method for estimation of Auto-Regressive Moving Average Vector models. It is not the entention to elect a winner amo...

  4. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  5. 40 CFR 60.715 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... plant coating formulation data are equivalent to Method 24 results, formulation data may be used. In the... for gas analysis. (f) Method 4 is used for stack gas moisture. (g) Methods 2, 2A, 2C, 2D, 3, and 4... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.715...

  6. 40 CFR 76.15 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods and procedures. 76.15... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The... Test Code 4.2 (1991), “Test Code for Coal Pulverizers” or ISO 9931 (1991), “Coal—Sampling of Pulverized...

  7. Lubricant Test Methods for Sheet Metal Forming

    DEFF Research Database (Denmark)

    Bay, Niels; Olsson, David Dam; Andreasen, Jan Lasson

    2008-01-01

    Sheet metal forming of tribologically difficult materials such as stainless steel, Al-alloys and Ti-alloys or forming in tribologically difficult operations like ironing, punching or deep drawing of thick plate requires often use of environmentally hazardous lubricants such as chlorinated paraffin...... proven successful and has in a number of examples assisted the substitution of environmentally hazardous lubricants by more friendly ones in industrial production....... appearing in different sheet forming operations such as stretch forming, deep drawing, ironing and punching. The laboratory tests have been especially designed to model the conditions in industrial production. Application of the tests for evaluating new lubricants before introducing them in production has...

  8. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment and the interp......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test....

  9. A method for testing the cosmic homogeneity with Shannon entropy

    Science.gov (United States)

    Pandey, Biswajit

    2013-04-01

    We propose a method for testing cosmic homogeneity based on the Shannon entropy in Information theory and test the potentials and limitations of the method on Monte Carlo simulations of some homogeneous and inhomogeneous 3D point process in a finite region of space. We analyse a set of N-body simulations to investigate the prospect of determining the scale of homogeneity with the proposed method and show that the method could serve as an efficient tool for the study of homogeneity.

  10. Comparison of Quantitative Antifungal Testing Methods for Textile Fabrics.

    Science.gov (United States)

    Imoto, Yasuo; Seino, Satoshi; Nakagawa, Takashi; Yamamoto, Takao A

    2017-01-01

     Quantitative antifungal testing methods for textile fabrics under growth-supportive conditions were studied. Fungal growth activities on unfinished textile fabrics and textile fabrics modified with Ag nanoparticles were investigated using the colony counting method and the luminescence method. Morphological changes of the fungi during incubation were investigated by microscopic observation. Comparison of the results indicated that the fungal growth activity values obtained with the colony counting method depended on the morphological state of the fungi on textile fabrics, whereas those obtained with the luminescence method did not. Our findings indicated that unique characteristics of each testing method must be taken into account for the proper evaluation of antifungal activity.

  11. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  12. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1990-01-01

    Methods are proposed for the construction of weakly parallel tests, that is, tests with the same test information function. A mathematical programing model for constructing tests with a prespecified test information function and a heuristic for assigning items to tests such that their information

  13. Testing method for ceramic armour and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2016-01-01

    TNO developed an alternative, more configuration independent ceramic test method than the Depth-of-Penetration test method. In this alternative test ceramic tiles and ceramic based armour are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  14. Testing method for ceramic armor and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2014-01-01

    TNO has developed an alternative, more configuration independent ceramic test method than the standard Depth-of-Penetration test method. In this test ceramic tiles and ceramic based armor are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  15. Method of determining an electrical property of a test sample

    DEFF Research Database (Denmark)

    2010-01-01

    A method of obtaining an electrical property of a test sample, comprising a non-conductive area and a conductive or semi-conductive test area, byperforming multiple measurements using a multi-point probe. The method comprising the steps of providing a magnetic field having field lines passing...... the electrical property of the test area....

  16. Ultrasonic methods of testing austenite weld joints and identifying defects

    Energy Technology Data Exchange (ETDEWEB)

    Grebennikov, V.V.; Glek, Yu.S.; Grigor' ev, M.V.; Gurvich, A.K.; Markelova, E.A.; Matynova, N.A.; Zakharov, Yu.V.

    1985-01-01

    Testing welds with an austenitic structure and determining the nature of the defect by ultrasonic methods are the most complex and urgent problems in non-destructive testing of nuclear power station equipment and in many other engineering fields. A dual-frequency method and device for ultrasonic testing of austenitic welds are described. A method is presented for identifying the defects, based on ultrasonic-wave diffraction on the defect tips.

  17. Reduction Methods for Real-time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian

    2016-01-01

    and complexity of kinematic nonlinear numerical substructures are presented, with special emphasis on the use of basis reduction methods. Three elements that can help to improve the accuracy are presented and illustrated. In kinematic nonlinear systems, various deformation modes are coupled through a nonlinear......Hybrid testing constitutes a cost-effective experimental full scale testing method. The method was introduced in the 1960's by Japanese researchers, as an alternative to conventional full scale testing and small scale material testing, such as shake table tests. The principle of the method...... is to divide a structure into a physical substructure and a numerical substructure, and couple these in a test. If the test is conducted in real-time it is referred to as real time hybrid testing. The hybrid testing concept has developed significantly since its introduction in the 1960', both with respect...

  18. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  19. Status and applications of echinoid (phylum echinodermata) toxicity test methods

    Energy Technology Data Exchange (ETDEWEB)

    Bay, S.; Burgess, R.; Nacci, D.

    1993-01-01

    The use of echinoderms for toxicity testing has focused primarily on sea urchins and sand dollars (Strongylocentrotus purpuratus, Arbacia punctulata, Lytechinus pictus, and Dendraster excentricus, for example). The status and relative sensitivity of various test methods are described. The most frequently used test methods consist of short-term exposures of sea urchin sperm or embryos; these tests can be easily conducted at all times of the year by using species with complementary spawning cycles or laboratory conditioned populations of a single species. Data from reference toxicant and effluent toxicity tests are summarized. Information on the precision and sensitivity of echinoid test methods are limited and preclude rigorous comparisons with other test methods. The available data indicate that the sensitivity and precision of these methods are comparable to short-term chronic methods for other marine invertebrates and fish. Recent application of the sperm test in toxicity identification evaluations (TIEs) and studies of effluent toxicity decay and sediment toxicity illustrate the versatility of this rapid (10 to 60 min exposure) test method. Embryo tests typically use a 48 to 96 h exposure period and measure the occurrence of embryo malformations. Most recent applications of the embryo test have been for the assessment of sediment elutriate toxicity. Adult echinoderms are not frequently used to assess effluent or receiving water toxicity. Recent studies have had success in using the adult life stage of urchins and sand dollars to assess the effects of contaminated sediment on growth, behavior, and bioaccumulation.

  20. Comparison of three standardized disc susceptibility testing methods for colistin.

    Science.gov (United States)

    Tan, Thean Yen; Ng, Lily Siew Yong

    2006-10-01

    With increasing antibiotic resistance in Gram-negative bacteria, the use of the polymyxins has increased in recent years. Antibiotic disc susceptibility testing remains the most widely used method in clinical laboratories, but there is very little data on the accuracy of disc testing methods for colistin. In this study, the accuracy of three standardized methods of disc susceptibility testing for colistin was compared with agar dilution. A total of 228 clinical isolates of Acinetobacter spp., Pseudomonas aeruginosa and Enterobacteriaceae were included in the study. Isolates were tested by agar dilution for susceptibility to colistin, and results were compared with those obtained by three disc susceptibility testing methods (product insert based on CLSI methodology, British BSAC and French SFM). Colistin displayed good activity against Acinetobacter spp., Klebsiella spp. and Escherichia coli (MIC(90) 2 mg/L) but was less active against P. aeruginosa (MIC(90) 4 mg/L) and Enterobacter spp. (MIC(90) >or= 128 mg/L). Totally, 81%, 79% and 89% of colistin-resistant isolates were falsely reported as susceptible when tested by the product insert, BSAC and SFM testing methods, respectively. There were no false-resistant results. Disc susceptibility testing methods are unreliable at detecting colistin resistance. Dilution methods should be the method of choice for susceptibility testing of colistin.

  1. 40 CFR 60.685 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standard of Performance for Wool Fiberglass Insulation Manufacturing Plants § 60.685 Test methods and procedures. (a) In conducting the performance tests...

  2. Development of a Flammability Test Method for Aircraft Blankets

    Science.gov (United States)

    1996-03-01

    Flammability testing of aircraft blankets was conducted in order to develop a fire performance test method and performance criteria for blankets supplied to commercial aircraft operators. Aircraft blankets were subjected to vertical Bunsen burner tes...

  3. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  4. Comparison of test methods for mould growth in buildings

    DEFF Research Database (Denmark)

    Bonderup, Sirid; Gunnarsen, Lars Bo; Knudsen, Sofie Marie

    2016-01-01

    The purpose of this work is to compare a range of test methods and kits for assessing whether a building structure is infested by mould fungi. A further purpose of this work is to evaluate whether air-based methods for sampling fungal emissions provide information qualifying decisions concerning...... methods measure different aspects relating to mould growth and vary in selectivity and precision. The two types of air samples indicated low levels of mould growth, even where the results of the other methods indicated high to moderate growth. With methods based on culture and DNA testing some differences...... in the species that each identified were apparent. In conclusion we found visual and olfactory inspection to be quite indicative of mould growth while none of the surface tests gave the complete representation as stand-alone tests. The air sampling methods seemed only to react to very comprehensive infestation...

  5. Psychometric Testing of the Method of Generations’ Mentality Type Measurement

    Directory of Open Access Journals (Sweden)

    Vlada I. Pishchik

    2013-01-01

    Full Text Available The article analyzes the mentality phenomenon in psychology and states the lack of clear, definite positions, concerning mentality, presents author's concept of mentality system, including nuclear and peripheral elements. On this basis, the initial survey, helping to develop the method of mentality measurement was conducted. The article presents author's method of generations’ mentality type measurement, carries out psychometric testing of method paragraphs. The paragraphs were tested on reliability-stability, reliability-conformity, factorial, convergent, constructive and empirical validities. The data of method testing on different samples are cited

  6. Qualind: A method for assessing the accuracy of automated tests.

    Science.gov (United States)

    Margolis, Robert H; Saly, George L; Le, Chap; Laurence, Jessica

    2007-01-01

    As audiology strives for cost containment, standardization, accuracy of tests, and accountability, greater use of automated tests is likely. Highly skilled audiologists employ quality control factors that contribute to test accuracy, but they are not formally included in test protocols, resulting in a wide range of accuracy, owing to the various skill and experience levels of clinicians. A method that incorporates validated quality indicators may increase accuracy and enhance access to accurate hearing tests. This report describes a quality assessment method that can be applied to any test that (1) requires behavioral or physiologic responses, (2) is associated with factors that correlate with accuracy, and (3) has an available independent measure of the dimension being assessed, including tests of sensory sensitivity, cognitive function, aptitude, academic achievement, and personality. In this report the method is applied to AMTAS, an automated method for diagnostic pure-tone audiometry.

  7. In silico toxicology – non-testing methods

    Directory of Open Access Journals (Sweden)

    Hannu eRaunio

    2011-06-01

    Full Text Available In silico toxicology in its broadest sense means anything that we can do with a computer in toxicology. Many different types of in silico methods have been developed to characterise and predict toxic outcomes in humans and environment. The term non-testing methods denote grouping approaches, structure-activity relationship (SAR, and expert systems. These methods are already used for regulatory purposes and it is anticipated that their role will be much more prominent in the near future. This Perspective will delineate the basic principles of non-testing methods and evaluate their role in current and future risk assessment of chemical compounds.

  8. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  9. Mode-Stirred Method Implementation for HIRF Susceptibility Testing and Results Comparison with Anechoic Method

    Science.gov (United States)

    Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.

    2001-01-01

    This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.

  10. Test equating, scaling, and linking methods and practices

    CERN Document Server

    Kolen, Michael J

    2014-01-01

    This book provides an introduction to test equating, scaling, and linking, including those concepts and practical issues that are critical for developers and all other testing professionals.  In addition to statistical procedures, successful equating, scaling, and linking involves many aspects of testing, including procedures to develop tests, to administer and score tests, and to interpret scores earned on tests. Test equating methods are used with many standardized tests in education and psychology to ensure that scores from multiple test forms can be used interchangeably.  Test scaling is the process of developing score scales that are used when scores on standardized tests are reported. In test linking, scores from two or more tests are related to one another. Linking has received much recent attention, due largely to investigations of linking similarly named tests from different test publishers or tests constructed for different purposes. In recent years, researchers from the education, psychology, and...

  11. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    on these efficiencies, an efficiency equation is determined by regression analysis. In the test method, there are no requirements on the ambient air temperature and the sky temperature. The paper will present an evaluation of the test method for a 12.5 m² flat plate solar collector panel from Arcon Solvarme A....../S. The solar collector panel investigated has 16 parallel connected horizontal absorber fins. CFD (Computational Fluid Dynamics) simulations, calculations with a solar collector simulation program SOLEFF (Rasmussen and Svendsen, 1996) and thermal experiments are carried out in the investigation......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...

  13. BSAC standardized disc susceptibility testing method (version 11).

    Science.gov (United States)

    Howe, R A; Andrews, J M

    2012-12-01

    This article highlights key amendments incorporated into version 11 of the BSAC standardized disc susceptibility testing method, available as Supplementary data at JAC Online (http://jac.oxfordjournals.org/) and on the BSAC web site (http://bsac.org.uk/susceptibility/guidelines-standardized-disc-susceptibility-testing-method/). The basic disc susceptibility testing method remains unchanged, but there have been a number of alterations to the interpretive criteria for certain organism/drug combinations due to continuing harmonization with the EUCAST MIC breakpoints and constant efforts to improve the reliability and clinical applicability of the guidance.

  14. A Simple Method for Determining Specific Yield from Pumping Tests

    Science.gov (United States)

    Ramsahoye, L.E.; Lang, Solomon Max

    1961-01-01

    A simpler solution which greatly reduces the time necessary to compute the specific yield by the pumping-test method of Remson and Lang (1955) is presented. The method consists of computing the volume of dewatered material in the cone of depression and comparing it with the total volume of discharged water. The original method entails the use of a slowly converging series to compute the volume of dewatered material. The solution given herein is derived directly from Darcy's law.

  15. TESTING METHODS FOR MECHANICALLY IMPROVED SOILS: RELIABILITY AND VALIDITY

    Directory of Open Access Journals (Sweden)

    Ana Petkovšek

    2017-10-01

    Full Text Available A possibility of in-situ mechanical improvement for reducing the liquefaction potential of silty sands was investigated by using three different techniques: Vibratory Roller Compaction, Rapid Impact Compaction (RIC and Soil Mixing. Material properties at all test sites were investigated before and after improvement with the laboratory and the in situ tests (CPT, SDMT, DPSH B, static and dynamic load plate test, geohydraulic tests. Correlation between the results obtained by different test methods gave inconclusive answers.

  16. 49 CFR 230.45 - Method of testing.

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.45 Method of testing. Steam gauges shall be compared with an accurate test gauge or dead weight tester. While under test load at the MAWP of the boiler to which the gauge will be applied...

  17. An easy method to test odour recognition in songbird hatchlings

    NARCIS (Netherlands)

    Caspers, B.A.; Hagelin, J.; Bock, S.; Krause, E.T.

    2015-01-01

    We describe an easy method to test odour detection and recognition in 1-d-old zebra finch hatchlings (Taeniopygia guttata). Day-old chicks beg in a stereotypical posture, which can be induced by directing gentle puffs of air from a plastic wash bottle near the face. We used this method to

  18. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  19. Standard test methods for vitrified ceramic materials for electrical applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 These test methods outline procedures for testing samples of vitrified ceramic materials that are to be used as electrical insulation. Where specified limits are mentioned herein, they shall not be interpreted as specification limits for completed insulators. 1.2 These test methods are intended to apply to unglazed specimens, but they may be equally suited for testing glazed specimens. The report section shall indicate whether glazed or unglazed specimens were tested. 1.3 The test methods appear as follows: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precaution statements are given in 11.3, 13.5, and 15.3.

  20. MIMO Device Performance Testing with the Wireless Cable Method

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Hentilä, Lassi

    2018-01-01

    Conducted cable testing has been dominantly utilized in the industry to evaluate multiple-input multiple-output (MIMO) capable mobile terminals. Desired testing signals can be guided directly to the antenna ports on the mobile terminal by radio frequency (RF) coaxial cables in the conducted cable...... of the wireless cable method is done both in simulation and active throughput measurements. Future directions and applicability of the wireless cable method are also discussed....

  1. Primer Stepper Motor Nomenclature, Definition, Performance and Recommended Test Methods

    Science.gov (United States)

    Starin, Scott; Shea, Cutter

    2014-01-01

    There has been an unfortunate lack of standardization of the terms and components of stepper motor performance, requirements definition, application of torque margin and implementation of test methods. This paper will address these inconsistencies and discuss in detail the implications of performance parameters, affects of load inertia, control electronics, operational resonances and recommended test methods. Additionally, this paper will recommend parameters for defining and specifying stepper motor actuators. A useful description of terms as well as consolidated equations and recommended requirements is included.

  2. Noise Radiation Measure-Sound Power and its Test Methods

    OpenAIRE

    Zeng Xianren; Zuo Yanyan

    2013-01-01

    This study mainly aims to study the characteristics and theory of sound radiation of steady-state vibration. Study shows that sound radiation power of steady-state vibration is constant. And taking excavator for experimental object by hemisphere surface method, the radiated sound power of the excavator is the same as testing the sound pressure on various surfaces based on relevant international standard. Finally, a test method of radiated sound power for cylindrical vibration object is proposed.

  3. A comparison of facemask and respirator filtration test methods.

    Science.gov (United States)

    Rengasamy, Samy; Shaffer, Ronald; Williams, Brandon; Smit, Sarah

    2017-02-01

    NIOSH published a Federal Register Notice to explore the possibility of incorporating FDA required filtration tests for surgical masks (SMs) in the 42 CFR Part 84 respirator certification process. There have been no published studies comparing the filtration efficiency test methods used for NIOSH certification of N95 filtering facepiece respirators (N95 FFRs) with those used by the FDA for clearance of SMs. To address this issue, filtration efficiencies of "N95 FFRs" including six N95 FFR models and three surgical N95 FFR models, and three SM models were measured using the NIOSH NaCl aerosol test method, and FDA required particulate filtration efficiency (PFE) and bacterial filtration efficiency (BFE) methods, and viral filtration efficiency (VFE) method. Five samples of each model were tested using each method. Both PFE and BFE tests were done using unneutralized particles as per FDA guidance document. PFE was measured using 0.1 µm size polystyrene latex particles and BFE with ∼3.0 µm size particles containing Staphylococcus aureus bacteria. VFE was obtained using ∼3.0 µm size particles containing phiX 174 as the challenge virus and Escherichia coli as the host. Results showed that the efficiencies measured by the NIOSH NaCl method for "N95 FFRs" were from 98.15-99.68% compared to 99.74-99.99% for PFE, 99.62-99.9% for BFE, and 99.8-99.9% for VFE methods. Efficiencies by the NIOSH NaCl method were significantly (p = filtration devices. The higher efficiencies obtained using PFE, BFE and VFE methods show that adding these supplemental particle penetration methods will not improve respirator certification.

  4. Standard test method for distribution coefficients of inorganic species by the batch method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of distribution coefficients of chemical species to quantify uptake onto solid materials by a batch sorption technique. It is a laboratory method primarily intended to assess sorption of dissolved ionic species subject to migration through pores and interstices of site specific geomedia. It may also be applied to other materials such as manufactured adsorption media and construction materials. Application of the results to long-term field behavior is not addressed in this method. Distribution coefficients for radionuclides in selected geomedia are commonly determined for the purpose of assessing potential migratory behavior of contaminants in the subsurface of contaminated sites and waste disposal facilities. This test method is also applicable to studies for parametric studies of the variables and mechanisms which contribute to the measured distribution coefficient. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement a...

  5. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  6. Testing autocorrelation and partial autocorrelation: Asymptotic methods versus resampling techniques.

    Science.gov (United States)

    Ke, Zijun; Zhang, Zhiyong Johnny

    2017-09-12

    Autocorrelation and partial autocorrelation, which provide a mathematical tool to understand repeating patterns in time series data, are often used to facilitate the identification of model orders of time series models (e.g., moving average and autoregressive models). Asymptotic methods for testing autocorrelation and partial autocorrelation such as the 1/T approximation method and the Bartlett's formula method may fail in finite samples and are vulnerable to non-normality. Resampling techniques such as the moving block bootstrap and the surrogate data method are competitive alternatives. In this study, we use a Monte Carlo simulation study and a real data example to compare asymptotic methods with the aforementioned resampling techniques. For each resampling technique, we consider both the percentile method and the bias-corrected and accelerated method for interval construction. Simulation results show that the surrogate data method with percentile intervals yields better performance than the other methods. An R package pautocorr is used to carry out tests evaluated in this study. © 2017 The British Psychological Society.

  7. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  8. Methods for behavioral testing of spinal cord injured rats.

    Science.gov (United States)

    Sedý, Jirí; Urdzíková, Lucia; Jendelová, Pavla; Syková, Eva

    2008-01-01

    Behavioral outcome in rats with spinal cord injury (SCI) is the most important factor for evaluating the extent of injury and treatment efficacy. For this purpose, a number of behavioral testing methods can be used. In this review, 35 individual locomotor, motor, sensory, sensory-motor, autonomic or electrophysiological behavioral tests, their weaknesses and strengths, testing conditions, the need for habituation, pre-training and/or food deprivation, methods for increasing the animals' skills, systematic testing protocols and methods for selecting the proper behavioral tests for particular injury models are discussed on the basis of a retrospective analysis of scientific studies published from 1995 to 2007. This review is primarily targeted towards researchers outside the field or to researchers new to the field of SCI.

  9. Test Method for Spalling of Fire Exposed Concrete

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Sørensen, Lars Schiøtt

    2005-01-01

    in many countries serve as standard specimens for testing the compressive strength. Consequently, the method is quick, cheap and easy to use in comparison to the alternative of testing full-scale or semi full-scale structures with correct humidity, load and boundary conditions. A number of concretes have......A new material test method is presented for determining whether or not an actual concrete may suffer from explosive spalling at a specified moisture level. The method takes into account the effect of stresses from hindered thermal expansion at the fire-exposed surface. Cylinders are used, which...... been studied using this method, and it is concluded that sufficient quantities of polypropylene fibres of suitable characteristics may prevent spalling of a concrete even when thermal expansion is restrained....

  10. Test method for spalling of fire exposed concrete

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt

    2005-01-01

    in many countries serve as standard specimens for testing the compressive strength. Consequently, the method is quick, cheap and easy to use in comparison to the alternative of testing full-scale or semi full-scale structures with correct humidity, load and boundary conditions. A number of concretes have......A new material test method is presented for determining whether or not an actual concrete may suffer from explosive spalling at a specified moisture level. The method takes into account the effect of stresses from hindered thermal expansion at the fire-exposed surface. Cylinders are used, which...... been studied using this method, and it is concluded that sufficient quantities of polypropylene fibres of suitable characteristics may prevent spalling of a concrete even when thermal expansion is restrained....

  11. Test Methods for Composites A Status Report. Volume 3: Shear Test Methods

    Science.gov (United States)

    1993-06-01

    suggests the use of specimens as per ASTM D3039 for tension test (Figure 9). Commonly employed widths vary from %" to 1". Use of tabs is usually not...Plane Shear Test Results for a Carbon Fiber Reinforced Epoxy Composite", Composites, Vol. 16, pp. 220-224, 1985. * 9. Chiao, C.C., Moore, R.L., and Chiao...34The Influence of Test Fixture Design on the losipescu Shear Test for Fiber Composite Materials", ASTM STP 1003, pp. 231- 260, 1989. * 30. Lee, S

  12. GeneQuence" Salmonella assay. Performance Tested Method 030201.

    Science.gov (United States)

    Alles, Susan; Mozola, Mark

    2009-01-01

    A study was conducted to validate the GeneQuence Salmonella DNA hybridization assay, Performance Tested Method 030201, for detection of Salmonella spp. in peanut butter. The study was organized by the AOAC Research Institute under its Emergency Response Validation program. Peanut butter samples inoculated with S. Typhimurium were prepared by an independent laboratory and shipped to study participants for testing. The set of blind-coded test samples consisted of five uninoculated controls, 20 portions inoculated with S. Typhimurium at a low level [determined by most probable number (MPN) analysis to contain 1.1 CFU/25 g portion], and 20 portions inoculated with S. Typhimurium at a higher level (11 CFU/25 g portion by MPN analysis). Samples were tested in parallel by the GeneQuence method and by the U.S. Food and Drug Administration's Bacteriological Analytical Manual reference culture procedure. All five control samples were negative by both methods. For the low-level samples, the same two samples were positive by both the GeneQuence and reference methods. For the high-level samples, the same 19 samples were positive by both methods. All positive GeneQuence assays were confirmed by plating from associated broth cultures. Agreement between the GeneQuence and reference methods was 100%. Sensitivity and specificity of the GeneQuence method were both 100%. Because neither the low- nor the high-level samples yielded the desired fractional positive results (5-15 positives out of 20 samples), a second trial was conducted. Samples in the second trial contained 0.1 and 0.5 CFU/25 g portion for the low and high levels, respectively. All five control samples were negative by both methods. For the low-level samples, the same two samples were positive by both the GeneQuence and reference methods. For the high-level samples, the same three samples were positive by both methods. All positive GeneQuence assays were confirmed by plating from associated broth cultures. Sensitivity

  13. Standard test methods for forming superplastic metallic sheet

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods describe procedures for determining the biaxial formability of a superplastic metallic sheet in a circular die. 1.2 The intent of these test methods are primarily to be used as tests of superplasticity as measured by the ability to form to a prescribed depth in a die cavity without rupturing. These test methods can also be used to generate material for the measurement of cavitation in the formed part. These can be used as go/no go criteria for qualification to a specification. 1.3 These test methods have been used successfully with aluminum alloys. The use of these test methods on other metals should be verified. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of ...

  14. Cone Penetration Testing: A Sound Method for Urban Archaeological Prospection

    NARCIS (Netherlands)

    Koster, K.

    2015-01-01

    Cone Penetration Testing (CPT) is a geotechnical in situ site investigation method and is widely applied in urbanized areas of the Netherlands. Approximately 20,000 CPTs are conducted in the Netherlands each year. The frequency of such testing, and the presence of archaeological deposits within the

  15. A Test Characteristic Curve Linking Method for the Testlet Model

    Science.gov (United States)

    Li, Yanmei; Bolt, Daniel M.; Fu, Jianbin

    2005-01-01

    When tests are made up of testlets, a testlet-based item response theory (IRT) model may be used to account for local dependence among items from a common testlet. This study presents a new test characteristic curve method to link calibrations based on the Bradlow, Wainer, and Wang (1999) testlet model. Procedures for calculating the test…

  16. Comparison of test methods for hearing protector attenuation measurements

    DEFF Research Database (Denmark)

    Poulsen, Torben

    1998-01-01

    the same procedure is used in Europe, USA, Australia and New Zealand, but the methods differ in the way the sound field is established and in the way the test subjects are instructed before the tests. Presently the international standard ISO 4869-1 for hearing protector attenuation is under revision...

  17. Fatigue testing of materials under extremal conditions by acoustic method

    NARCIS (Netherlands)

    Baranov, VM; Bibilashvili, YK; Karasevich, VA; Sarychev, GA

    2004-01-01

    Increasing fuel cycle time requires fatigue testing of the fuel clad materials for nuclear reactors. The standard high-temperature fatigue tests are complicated and tedious. Solving this task is facilitated by the proposed acoustic method, which ensures observation of the material damage dynamics,

  18. Inter-instrumental method transfer of chiral capillary electrophoretic methods using robustness test information.

    Science.gov (United States)

    De Cock, Bart; Borsuk, Agnieszka; Dejaegher, Bieke; Stiens, Johan; Mangelings, Debby; Vander Heyden, Yvan

    2014-08-01

    Capillary electrophoresis (CE) is an electrodriven separation technique that is often used for the separation of chiral molecules. Advantages of CE are its flexibility, low cost and efficiency. On the other hand, the precision and transfer of CE methods are well-known problems of the technique. Reasons for the more complicated method transfer are the more diverse instrumental differences, such as total capillary lengths and capillary cooling systems; and the higher response variability of CE methods compared to other techniques, such as liquid chromatography (HPLC). Therefore, a larger systematic change in peak resolutions, migration times and peak areas, with a loss of separation and efficiency may be seen when a CE method is transferred to another laboratory or another type of instrument. A swift and successful method transfer is required because development and routine use of analytical methods are usually not performed in the same laboratory and/or on the same type of equipment. The aim of our study was to develop transfer rules to facilitate CE method transfers between different laboratories and instruments. In our case study, three β-blockers were chirally separated and inter-instrumental transfers were performed. The first step of our study was to optimise the precision of the chiral CE method. Next, a robustness test was performed to identify the instrumental and experimental parameters that were most influencing the considered responses. The precision- and the robustness study results were used to adapt instrumental and/or method settings to improve the transfer between different instruments. Finally, the comparison of adapted and non-adapted transfers allowed deriving some rules to facilitate CE method transfers. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Alternative methods for the replacement of eye irritation testing.

    Science.gov (United States)

    Lotz, Christian; Schmid, Freia F; Rossi, Angela; Kurdyn, Szymon; Kampik, Daniel; De Wever, Bart; Walles, Heike; Groeber, Florian K

    2016-01-01

    In the last decades significant regulatory attempts were made to replace, refine and reduce animal testing to assess the risk of consumer products for the human eye. As the original in vivo Draize eye test has been criticized for limited predictivity, costs and ethical issues, several animal-free test methods have been developed to categorize substances according to the global harmonized system (GHS) for eye irritation.This review summarizes the progress of alternative test methods for the assessment of eye irritation. Based on the corneal anatomy and the current knowledge of the mechanisms causing eye irritation, different ex vivo and in vitro methods will be presented and discussed in regard of possible limitations and their status of regulatory acceptance. In addition to established in vitro models, this review will also highlight emerging, full thickness cornea models that might be applicable to predict all GHS categories.

  20. Small punch test evaluation methods for material characterisation

    Science.gov (United States)

    Janča, Adam; Siegl, Jan; Haušild, Petr

    2016-12-01

    The Small Punch Test (SPT) is one of the most widespread mechanical testing methods using miniaturized specimens. The paper presented deals with the time independent SPT, in which a flat specimen is bent by means of a (hemi)spherical punch moving at a constant velocity. The main goal is to relate the measured data to deformation processes taking place during specimen loading. Understanding of such relations is crucial for characterizing a material using any non-standardized experimental procedure. Using enhanced instrumentation, not only traditional load-displacement or load-deflection curves could be obtained, but also specimen thinning could be continuously measured and evaluated. Five alloys having a broad range of mechanical properties were tested. The results obtained were evaluated using both traditional and newly proposed methods and they were correlated with results of the conventional tensile test. The methods proposed seem to lead to a universal correlation between SPT results and tensile characteristics.

  1. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  2. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  3. Testing Method for External Cladding Systems - Incerc Romania

    Science.gov (United States)

    Simion, A.; Dragne, H.

    2017-06-01

    This research presents a new testing method in a natural scale for external cladding systems tested on buildings with minimum than 3 floors [1]. The testing method is unique in Romania and it is similar about many fire testing current methods from European Union states. Also, presents the fire propagation and the effect of fire smoke on the building façade composed of thermal insulation. Laboratory of testing and research for building fire safety from National Institute INCERC Bucharest, provides a test method for determining the fire performance characteristics of non-loadbearing external cladding systems and external wall insulation systems when applied to the face of a building and exposed to an external fire under controlled conditions [2]. The fire exposure is representative of an external fire source or a fully-developed (post-flashover) fire in a room, venting through an opening such as a window aperture that exposes the cladding to the effects of external flames, or an external fire source. On the future, fire tests will be experimented for answer demande a number of high-profile fires where the external facade of tall buildings provided a route for vertical fire spread.

  4. SPF Full-scale emissions test method development status ...

    Science.gov (United States)

    This is a non-technical presentation that is intended to inform ASTM task group members about our intended approach to full-scale emissions testing that includes the application of spray foam in an environmental chamber. The presentation describes the approach to emissions characterization, types of measurement systems employed, and expected outcomes from the planned tests. Purpose of this presentation is to update the ASTM D22.05 work group regarding status of our full-scale emissions test method development.

  5. Test Methods for Telemetry Systems and Subsystems Volume 1: Test Methods for Vehicle Telemetry Systems

    Science.gov (United States)

    2012-05-01

    relating to accelerometers , strain gages, servo types, variable capacitive , piezoelectric, piezoresistive - http://www.endevco.com/ Version 1.03...2-4 2.7 Gain Stability with Source Capacitance Test ....................................................... 2-5 2.8 Gain Stability with Temperature...deviation PCM Pulse code modulation PM Phase modulation PN Pseudo noise RC Resistance capacitance RCP Right circular polarization RF Radio

  6. A new method for testing isotropy with Shannon entropy

    Science.gov (United States)

    Pandey, Biswajit

    2016-10-01

    We propose a method for testing isotropy of a three-dimensional distribution using Shannon entropy. We test the method on some Monte Carlo simulations of isotropic and anisotropic distributions and find that the method can effectively identify and characterize different types of hemispherical asymmetry inputted in a distribution. We generate anisotropic distributions by introducing pockets of different densities inside homogeneous and isotropic distributions and find that the proposed method can effectively quantify the degree of anisotropy and determine the geometry of the pockets introduced. We also consider spherically symmetric radially inhomogeneous distributions which are anisotropic at all points other than the centre and find that such anisotropy can be easily characterized by our method. We use a semi-analytic galaxy catalogue from the Millennium simulation to study the anisotropies induced by the redshift space distortions and find that the method can separate such anisotropies from a general one. The method may be also suitably adapted for any two-dimensional maps on the celestial sphere to study the hemispherical asymmetry in other cosmological observations.

  7. [Modification of the Photobacterium phosphoreum toxicity test method].

    Science.gov (United States)

    Lin, Z; Yu, H; Xu, S; Wang, L

    2001-03-01

    In order to reduce the variation of Photobacterium phosphoreum luminous intensity during testing, the Photobacterium phosphoreum toxicity test was modified by a correction factor, PIacetone, in this paper. The effects of magnetic stirring time, culture time, culture generation and culture temperature on the measured results were discussed. The modified method had good laboratory repeatability and the relative standard deviation (RSD) was between 2.1% and 13.1%. Reliable data could be obtained using the modified method. It would be beneficial to the development of the quantitative structure-activity relationships on multicomponent organic compounds.

  8. Study of test script design methods for Web Service performance testing

    Science.gov (United States)

    Xu, Peng

    2017-09-01

    Web Service interface technology is more and more widely applied in information system. And more requirements of Web Service performance testing are demanded. Nevertheless, designing the test script for performance testing is hard to take into practice. In this paper, two kinds of test script design methods for Web Service performance testing are presented by using LoadRunner and SOAP UI tools. That is The Service Call Method and The SOAP Method.

  9. Nondestructive testing method for a new generation of electronics

    Directory of Open Access Journals (Sweden)

    Azin Anton

    2018-01-01

    Full Text Available The implementation of the Smart City system needs reliable and smoothly operating electronic equipment. The study is aimed at developing a nondestructive testing method for electronic equipment and its components. This method can be used to identify critical design defects of printed circuit boards (PCB and to predict their service life, taking into account the nature of probable operating loads. The study uses an acoustic emission method to identify and localize critical design defects of printed circuit boards. Geometric dimensions of detected critical defects can be determined by the X-ray tomography method. Based on the results of the study, a method combining acoustic emission and X-ray tomography was developed for nondestructive testing of printed circuit boards. The stress-strain state of solder joints containing detected defects was analyzed. This paper gives an example of using the developed method for estimating the degree of damage to joints between PCB components and predicting the service life of the entire PCB.

  10. Robust test method for time-course microarray experiments

    Directory of Open Access Journals (Sweden)

    George Stephen L

    2010-07-01

    Full Text Available Abstract Background In a time-course microarray experiment, the expression level for each gene is observed across a number of time-points in order to characterize the temporal trajectories of the gene-expression profiles. For many of these experiments, the scientific aim is the identification of genes for which the trajectories depend on an experimental or phenotypic factor. There is an extensive recent body of literature on statistical methodology for addressing this analytical problem. Most of the existing methods are based on estimating the time-course trajectories using parametric or non-parametric mean regression methods. The sensitivity of these regression methods to outliers, an issue that is well documented in the statistical literature, should be of concern when analyzing microarray data. Results In this paper, we propose a robust testing method for identifying genes whose expression time profiles depend on a factor. Furthermore, we propose a multiple testing procedure to adjust for multiplicity. Conclusions Through an extensive simulation study, we will illustrate the performance of our method. Finally, we will report the results from applying our method to a case study and discussing potential extensions.

  11. Non-animal test methods for predicting skin sensitization potentials.

    Science.gov (United States)

    Mehling, Annette; Eriksson, Tove; Eltze, Tobias; Kolle, Susanne; Ramirez, Tzutzuy; Teubner, Wera; van Ravenzwaay, Bennard; Landsiedel, Robert

    2012-08-01

    Contact allergies are complex diseases, and it is estimated that 15-20 % of the general population suffers from contact allergy, with increasing prevalence. Evaluation of the sensitization potential of a substance is usually carried out in animal models. Nowadays, there is much interest in reducing and ultimately replacing current animal tests. Furthermore, as of 2013, the EU has posed a ban on animal testing of cosmetic ingredients that includes skin sensitization. Therefore, predictive and robust in vitro tests are urgently needed. In order to establish alternatives to animal testing, the in vitro tests must mimic the very complex interactions between the sensitizing chemical and the different parts of the immune system. This review article summarizes recent efforts to develop in vitro tests for predicting skin sensitizers. Cell-based assays, in chemico methods and, to a lesser extent, in silico methods are presented together with a discussion of their current status. With considerable progress having been achieved during the last years, the rationale today is that data from different non-animal test methods will have to be combined in order to obtain reliable hazard and potency information on potential skin sensitizers.

  12. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  13. Testing K. Patrick Method of Psychopathy Diagnosis in Russian Sample

    Directory of Open Access Journals (Sweden)

    Atadzhykova Y.A.,

    2015-12-01

    Full Text Available The article is devoted to the development of a method of diagnosing psychopathy, or antisocial (dissocial personality disorder. Modern researchers mostly use the methods of experiment, expert assessment, clinical interview or different combinations for personality disorders, including psychopathy. However, nowadays there is a growing need in development of a psychopathy diagnosis method which would be less labour-intensive, less expensive and more objective. One of the recently developed models of psychopathy is Trierarchic conceptualization by C. Patrick, it offers a new way to operationalize and diagnose psychopathy. The authors had tested this method in the Russian population, including both common sample as well as criminal offender sample consisting of individuals that have been suspected, accused or convicted of violent crimes. The subject of the current research is psychopathic traits measured by the tested method. We had carried out statistical and content analyzes of the data. Our study allowed to conclude that tested Russian version of the Triarchic Psychopathy Measure is effective enough to be used for research purposes. However, further research is required in order to render this measure valid to practical use.

  14. Critical wall shear stress for the EHEDG test method

    DEFF Research Database (Denmark)

    Jensen, Bo Boye Busk; Friis, Alan

    2004-01-01

    In order to simulate the results of practical cleaning tests on closed processing equipment, based on wall shear stress predicted by computational fluid dynamics, a critical wall shear stress is required for that particular cleaning method. This work presents investigations that provide a critical...... wall shear stress of 3 Pa for the standardised EHEDG cleaning test method. The cleaning tests were performed on a test disc placed in a radial flowcell assay. Turbulent flow conditions were generated and the corresponding wall shear stresses were predicted from CFD simulations. Combining wall shear...... stress predictions from a simulation using the low Re k-epsilon and one using the two-layer model of Norris and Reynolds were found to produce reliable predictions compared to empirical solutions for the ideal flow case. The comparison of wall shear stress curves predicted for the real RFC...

  15. Reduction Method for Real-Time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian; Poulsen, Peter Noe

    2014-01-01

    to reformulate kinematic nonlinear equations of motion into a sum of constant matrices each multiplied by a reduced coordinate decreasing the assembling time. Furthermore the method allows for cutting off some of the higher frequency content not representing real physics decreasing the stability requirement......Real-time hybrid testing combines testing of physical components with numerical simulations. The concept of the method requires that the numerical simulations should be executed in real time. However, for large numerical models including nonlinear behavior a combination of computationally costly...... of choosing a sufficient basis a composite beam and a cantilever beam including kinematic nonlinearities and exposed to harmonic loadings are analyzed. To reduce locking modes with higher order terms are included. From the analysis it is concluded that the method exhibits encouraging potential with respect...

  16. Residual flexibility test method for verification of constrained structural models

    Science.gov (United States)

    Admire, John R.; Tinker, Michael L.; Ivey, Edward W.

    1994-01-01

    A method is described for deriving constrained modes and frequencies from a reduced model based on a subset of the free-free modes plus the residual effects of neglected modes. The method involves a simple modification of the MacNeal and Rubin component mode representation to allow development of a verified constrained (fixed-base) structural model. Results for two spaceflight structures having translational boundary degrees of freedom show quick convergence of constrained modes using a measureable number of free-free modes plus the boundary partition of the residual flexibility matrix. This paper presents the free-free residual flexibility approach as an alternative test/analysis method when fixed-base testing proves impractical.

  17. Standard test method for determining residual stresses by the hole-drilling strain-gage method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 Residual Stress Determination: 1.1.1 This test method specifies a hole-drilling procedure for determining residual stress profiles near the surface of an isotropic linearly elastic material. The test method is applicable to residual stress profile determinations where in-plane stress gradients are small. The stresses may remain approximately constant with depth (“uniform” stresses) or they may vary significantly with depth (“non-uniform” stresses). The measured workpiece may be “thin” with thickness much less than the diameter of the drilled hole or “thick” with thickness much greater than the diameter of the drilled hole. Only uniform stress measurements are specified for thin workpieces, while both uniform and non-uniform stress measurements are specified for thick workpieces. 1.2 Stress Measurement Range: 1.2.1 The hole-drilling method can identify in-plane residual stresses near the measured surface of the workpiece material. The method gives localized measurements that indicate the...

  18. Recommended methods for purification of solvents and tests for impurities

    CERN Document Server

    Coetzee, J F

    1982-01-01

    Recommended Methods for Purification of Solvents and Tests for Impurities is a compilation of recommended procedures for purification of solvents and tests for solvent impurities. Ten solvents are covered: acetonitrile, sulfolane, propylene carbonate, dimethyl sulfoxide, dimethylformamide, hexamethylphosphoramide, pyridine, ethylenediamine, N-methylacetamide, and N-methylpropionamide. This book is comprised of 12 chapters and opens with an introduction to general aspects of impurity effects. The rationale for the selection of solvent is explained, and the relative reactivities of solutes in di

  19. A Model Based Security Testing Method for Protocol Implementation

    Directory of Open Access Journals (Sweden)

    Yu Long Fu

    2014-01-01

    Full Text Available The security of protocol implementation is important and hard to be verified. Since the penetration testing is usually based on the experience of the security tester and the specific protocol specifications, a formal and automatic verification method is always required. In this paper, we propose an extended model of IOLTS to describe the legal roles and intruders of security protocol implementations, and then combine them together to generate the suitable test cases to verify the security of protocol implementation.

  20. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  1. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  2. 40 CFR 265.1034 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... -possible as described in Reference Method 21. (7) The arithmetic difference between the maximum... information as may be necessary to determine the conditions of the performance tests. Operations during... and the mean organic concentration of each waste stream managed in the unit. (2) Using knowledge of...

  3. 40 CFR 264.1034 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... described in Reference -Method 21. (7) The arithmetic difference between the maximum concentration indicated... information as may be necessary to determine the conditions of the performance tests. Operations during... and the mean organic concentration of each waste stream managed in the unit. (2) Using knowledge of...

  4. TROPICAL COLLECTOR URCHIN, TRIPNEUSTES GRATILLA, FERTILIZATION TEST METHOD

    Science.gov (United States)

    This document describes a fertilization method to estimate the chronic toxicity of effluents and receiving waters to the gametes of the tropical sea urchin (Tripneustes gratilla). This toxicity test measures the fertilizing capacity of sperm following a static, non-renewal 60-mi...

  5. Test method for measuring insulation values of cryogenic pipes

    NARCIS (Netherlands)

    Velthuis, J.F.M.; Blokland, H.; Klaver, B.W.; Beld, C. van de

    2010-01-01

    In this paper a large-area heat flux and temperature sensor (HFT) is used for the evaluation of the insulation value of cryogenic pipes. The HFT is flexible and clamp-on. The test method is relatively simple and can be used in-situ. The HFT makes it possible to monitor insulation performance over

  6. Considerations and Methods for Usability Testing with Children

    DEFF Research Database (Denmark)

    Andersen, Malene Hjortboe; Khalid, Md. Saifuddin; Brooks, Eva Irene

    2017-01-01

    and then synthesized by applying the constant comparative method. The synthesis of the literature review is based on the identified thematic priorities, which are categorized as follows: 1) the motivation for involving children as test persons in design processes, 2) definitions of usability, 3) practical...

  7. 40 CFR 60.244 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... Fertilizer Industry: Granular Triple Superphosphate Storage Facilities § 60.244 Test methods and procedures... quantities of product are being cured or stored in the facility. (1) Total granular triple superphosphate is at least 10 percent of the building capacity, and (2) Fresh granular triple superphosphate is at...

  8. Report on the Standardization Project "Formal Methods in Conformance Testing"

    NARCIS (Netherlands)

    Baumgarten, B.; Hogrefe, D.; Heymer, S.; Burkhardt, H.-J.; Giessler, A.; Tretmans, G.J.

    1996-01-01

    This paper presents the latest developments in the “Formal Methods in Conformance Testing��? (FMCT) project of ISO and ITU–T. The project has been initiated to study the role of formal description techniques in the conformance testing process. The goal is to develop a standard that defines the

  9. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  10. Interesting Developments in Testing Methods Applied to Foundation Piles

    Science.gov (United States)

    Sobala, Dariusz; Tkaczyński, Grzegorz

    2017-10-01

    Both: piling technologies and pile testing methods are a subject of current development. New technologies, providing larger diameters or using in-situ materials, are very demanding in terms of providing proper quality of execution of works. That concerns the material quality and continuity which define the integral strength of pile. On the other side we have the capacity of the ground around the pile and its ability to carry the loads transferred by shaft and pile base. Inhomogeneous nature of soils and a relatively small amount of tested piles imposes very good understanding of small amount of results. In some special cases the capacity test itself form an important cost in the piling contract. This work presents a brief description of selected testing methods and authors remarks based on cooperation with Universities constantly developing new ideas. Paper presents some experience based remarks on integrity testing by means of low energy impact (low strain) and introduces selected (Polish) developments in the field of closed–end pipe piles testing based on bi-directional loading, similar to Osterberg idea, but without sacrificial hydraulic jack. Such test is suitable especially when steel piles are used for temporary support in the rivers, where constructing of conventional testing appliance with anchor piles or kentledge meets technical problems. According to the author’s experience, such tests were not yet used on the building site but they bring a real potential especially, when the displacement control can be provided from the river bank using surveying techniques.

  11. The new null testing method for the special optical window

    Science.gov (United States)

    Huang, Changchun

    2009-07-01

    The high speed, high precision and wide range specifications are requirement for the modern aircraft, which the traditional hemispherical dome can't achieve now, and the novel conformal window instead can enhance the aerodynamic performance of the aircraft obviously. To reduce the aerodynamic drag and radar cross-section, the window geometry is generally aspheric in shape. As a result, the involved fabrication and testing processes are much more challenging than that of conventional optics and must be mastered before these windows and systems can be implemented at an acceptable cost and risk. Metrology is one of the critical areas required to advance the conformal window technology. But as the surface of these conformal windows is not the traditional sphere lens, the measurement method for it is infeasible with the conventional optics measurement processes. This paper we express the development of testing technology for the special conformal windows in brief, and emphatically introduces one available novel testing method- a new null testing, and here based on the theory of compensation methods, The principle of Offner's refractive null lens has been extended to test the transmission wavefront through conformal window optics and provide feedback during surface fabrication. a compensator system for the was designed for the conformal window is given which parameters are 100mm for its aperture and two parabolic surface as conformal window, the final residual wavefront error(RMS) of which is less than 1/20λ(λ=632.8nm).

  12. A New Static and Fatigue Compression Test Method for Composites

    DEFF Research Database (Denmark)

    Bech, Jakob Ilsted; Goutianos, Stergios; Løgstrup Andersen, Tom

    2011-01-01

    A new test method to determine the compressive properties of composite materials under both static and fatigue loading was developed. The novel fixture is based on the concept of transmitting the load by a fixed ratio of end-to-shear loading. The end-to-shear load ratio is kept fixed during the t....../epoxy and glass/polyester composite systems. Repeatable results and acceptable failure modes are obtained under both static and fatigue loading.......A new test method to determine the compressive properties of composite materials under both static and fatigue loading was developed. The novel fixture is based on the concept of transmitting the load by a fixed ratio of end-to-shear loading. The end-to-shear load ratio is kept fixed during...... the test through a mechanical mechanism, which automatically maintains the gripping pressure. The combined loading method has proven very efficient in static loading and is used in the new fixture which is specially designed for fatigue testing. Optimum gripping (shear loading) and alignment of the test...

  13. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).

  14. ISO standards on test methods for water radioactivity monitoring.

    Science.gov (United States)

    Calmet, D; Ameon, R; Bombard, A; Forte, M; Fournier, M; Herranz, M; Jerome, S; Kwakman, P; Llaurado, M; Tokonami, S

    2013-11-01

    Water is vital to humans and each of us needs at least 1.5L of safe water a day to drink. Beginning as long ago as 1958 the World Health Organization (WHO) has published guidelines to help ensure water is safe to drink. Focused from the start on monitoring radionuclides in water, and continually cooperating with WHO, the International Standardization Organization (ISO) has been publishing standards on radioactivity test methods since 1978. As reliable, comparable and 'fit for purpose' results are an essential requirement for any public health decision based on radioactivity measurements, international standards of tested and validated radionuclide test methods are an important tool for production of such measurements. This paper presents the ISO standards already published that could be used as normative references by testing laboratories in charge of radioactivity monitoring of drinking water as well as those currently under drafting and the prospect of standardized fast test methods in response to a nuclear accident. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Novel Trends in Optical Non-Destructive Testing Methods

    Science.gov (United States)

    Huke, P.; Klattenhoff, R.; von Kopylow, C.; Bergmann, R. B.

    2013-07-01

    Non-destructive testing (NDT) describes a wide range of methods for measuring and comparing physical quantities against a nominal condition. In this paper we describe and compare different optical NdT (ONDT)-methods with respect to their characteristics and capability for different measurement tasks. ONDT may be specified in two categories, passive and active. The NDT principles of the first category just use a measurement method like view inspection, elipsometry or reflectometry to detect defects which are easily accessible. The principles of the second category use an excitation force, such as heat or mechanical vibration introduced by transducers to detect hidden defects. This category can be specified into two subcategories. The first subcategory "time-/depth-resolved" includes measurement methods delivering detailed information of the geometric features of a hidden defect. Therefore the excitation of the material and the detection of the reaction have to provide a ti! me step which enables depth-solved measurements. Phase-resolved thermography and laser ultrasound are examples for this category. The second subcategory "Integrating" includes measurement technique coupled with an excitation that enables detection of defects but not evaluation of their geometric features. Examples for these measurement techniques are shearography, reflectometry, vibrometry and thermography coupled with excitation method like simple heating or loading with a constant force. We demonstrate experimental results obtained using methods developed in our institute and highlight directions of further development.

  16. 40 CFR 63.849 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... this chapter for gas analysis; (4) Method 13A or Method 13B in appendix A to part 60 of this chapter... analysis shall be performed using Method 13A or Method 13B in appendix A to part 60 of this chapter for TF... method for a specific plant and has received previous approval from the Administrator or the applicable...

  17. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  18. BSAC standardized disc susceptibility testing method (version 10).

    Science.gov (United States)

    Andrews, J M; Howe, R A

    2011-12-01

    The BSAC standardized disc susceptibility testing method remains unchanged, but there are considerable changes to the interpretative criteria due to continuing harmonization with the European Committee on Antimicrobial Susceptibility Testing (EUCAST) MIC breakpoints. There are a number of agents for which interpretative criteria have been removed. These MIC and/or zone diameter breakpoints will be published on the BSAC web site as a 'Legacy' table; they may be used for research or comparative purposes, but are not recommended for clinical management. Notably, testing of staphylococci for susceptibility to glycopeptides by disc diffusion has been removed because this method has been found to be unreliable, particularly for the detection of low-level resistance; low-level vancomycin resistance in staphylococci is increasingly deemed to be of clinical relevance. The tables for anaerobes have been expanded to include MIC breakpoints that have been determined by EUCAST. There are currently no zone diameter breakpoints for these organisms and an MIC method is recommended if susceptibility testing is required.

  19. Canadian Health Measures Survey pre-test: design, methods, results.

    Science.gov (United States)

    Tremblay, Mark; Langlois, Renée; Bryan, Shirley; Esliger, Dale; Patterson, Julienne

    2007-01-01

    The Canadian Health Measures Survey (CHMS) pre-test was conducted to provide information about the challenges and costs associated with administering a physical health measures survey in Canada. To achieve the specific objectives of the pre-test, protocols were developed and tested, and methods for household interviewing and clinic testing were designed and revised. The cost, logistics and suitability of using fixed sites for the CHMS were assessed. Although data collection, transfer and storage procedures are complex, the pre-test experience confirmed Statistics Canada's ability to conduct a direct health measures survey and the willingness of Canadians to participate in such a health survey. Many operational and logistical procedures worked well and, with minor modifications, are being employed in the main survey. Fixed sites were problematic, and survey costs were higher than expected.

  20. Foodproof Salmonella Detection Kit. Performance Tested Method 120301.

    Science.gov (United States)

    Lindhardt, Charlotte; Schönenbrücher, Holger; Slaghuis, Jörg; Bubert, Andreas; Ossmer, Rolf; Junge, Benjamin; Berghof-Jäger, Kornelia

    2009-01-01

    The foodproof Salmonella Detection Kit was previously validated in the Performance Tested Methods program for the detection of Salmonella species in a variety of foods, including milk powder, egg powder, coconut, cocoa powder, chicken breast, minced meat, sliced sausage, sausage, smoked fish, pasta, white pepper, cumin, dough, wet pet food, dry pet food, ice cream, watermelon, sliced cabbage, food dye, and milk chocolate. The method was shown to be equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) and the U.S. Department of Agriculture, Food Safety and Inspection Service's Microbiology Laboratory Guidebook reference culture procedures. In the first Emergency Response Validation (ERV) extension study, peanut butter was inoculated with S. enterica. ser Typhimurium. For the low inoculation level (1.08 CFU/25 g), a Chi-square value of 2.25 indicated that there was no significant performance difference between the foodproof Salmonella Detection Kit and the FDA-BAM reference method. For high-level inoculation (11.5 CFU/25 g) and uninoculated control, there was 100% agreement between the methods. In the second ERV extension study, peanut butter was inoculated with S. enterica. ser Typhimurium. For both inoculation levels (0.1 and 0.5 CFU/25 g by most probable number), Chi-square values of 0 indicated that there was no significant performance difference between foodproof Salmonella Detection Kit and the FDA-BAM reference method.

  1. Harmonic Adaptability Remote Testing Method for Offshore Wind Turbines

    Directory of Open Access Journals (Sweden)

    Zimin Jiang

    2017-11-01

    Full Text Available Harmonic adaptability (HA capability is required for large-scale onshore and offshore wind turbines (WTs connected to the grid. To ensure that the distortion of the harmonic voltage at the grid access point generated by grid simulator is in accordance with the required value, this paper proposes an on-site HA remote testing method for offshore WTs to eliminate submarine cable effects. The deviation compensation method detects the integer harmonic voltage distortion based on instantaneous reactive power theory, and the deviation from the required value is compensated by series active power filter. In order to further reduce the capacity of the designed device, integer harmonics close to the resonant frequency are suppressed by the selective harmonic damping (SHD method initially. Owing to the attenuation of extreme amplification, the deviation determining the equipment capacity is decreased correspondingly. As a small synthesized impedance working for the selected frequency can suppress the amplification significantly, a low power ratings design for the SHD method can be achieved, and undesired resonance can be avoided. Simulation results indicate that the proposed method can make the harmonic distortion within the error tolerance.

  2. Standard Test Method for Environmental Resistance of Aerospace Transparencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers determination of the effects of exposure to thermal shock, condensing humidity, and simulated weather on aerospace transparent enclosures. 1.2 This test method is not recommended for quality control nor is it intended to provide a correlation to actual service life. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3.1 Exceptions—Certain inch-pound units are furnished in parentheses (not mandatory) and certain temperatures in Fahrenheit associated with other standards are also furnished. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Performing Allen's test in immobile hand: The Esmarch bandage method

    Directory of Open Access Journals (Sweden)

    Nebil Yesiloglu

    2015-12-01

    Full Text Available In this study, an alternative method of assessing hand vascular flow using a modification of Allen's test is presented. This technique may be helpful for patients who have immobile hands due to severe trauma, patients scheduled for free tissue transfer reconstruction, patients under general anesthesia in intensive care units that require serial arterial blood gas analyses, and emergency coronary by-pass candidates who decided to receive radial arterial grafts. [Hand Microsurg 2015; 4(3.000: 83-85

  4. Fracture Test Methods for Plastically Responding COPV Liners

    Science.gov (United States)

    Dawicke, David S.; Lewis, Joseph C.

    2009-01-01

    An experimental procedure for evaluating the validity of using uniaxial tests to provide a conservative bound on the fatigue crack growth rate behavior small cracks in bi-axially loaded Composite Overwrapped Pressure Vessel (COPV) liners is described. The experimental procedure included the use of a laser notch to quickly generate small surface fatigue cracks with the desired size and aspect ratios. An out-of-plane constraint system was designed to allow fully reversed, fully plastic testing of thin sheet uniaxial coupons. Finally, a method was developed to determine to initiate small cracks in the liner of COPVs.

  5. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  6. Anechoic chamber qualification: traverse method, inverse square law analysis method, and nature of test signal.

    Science.gov (United States)

    Cunefare, Kenneth A; Biesel, Van B; Tran, John; Rye, Ryan; Graf, Aaron; Holdhusen, Mark; Albanese, Anne-Marie

    2003-02-01

    Qualification of anechoic chambers is intended to demonstrate that the chamber supports the intended free-field environment within some permissible tolerance bounds. Key qualification issues include the method used to obtain traverse data, the analysis method for the data, and the use of pure tone or broadband noise as the chamber excitation signal. This paper evaluates the relative merits of continuous versus discrete traverses, of fixed versus optimal reference analysis of the traverse data, and of the use of pure tone versus broadband signals. The current practice of using widely space discrete sampling along a traverse is shown to inadequately sample the complexity of the sound field extant with pure tone traverses, but is suitable for broadband traverses. Continuous traverses, with spatial resolution on the order of 15% of the wavelength at the frequency of interest, are shown to be necessary to fully resolve the spatial complexity of pure tone qualifications. The use of an optimal reference method for computing the deviations from inverse square law is shown to significantly improve the apparent performance of the chamber for pure tone qualifications. Finally, the use of broadband noise as the test signal, as compared to pure tone traverses over the same span, is demonstrated to be a marginal indicator of chamber performance.

  7. 40 CFR 60.583 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ...) as follows: (1) Method 24 for analysis of inks. If nonphotochemically reactive solvents are used in... velocity traverses; (4) Method 2 for velocity and volumetric flow rates; (5) Method 3 for gas analysis; (6... by Method 24, ink manufacturers' formulation data, or plant blending records. (c) To demonstrate...

  8. Standard test method for determining atmospheric chloride deposition rate by wet candle method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a wet candle device and its use in measuring atmospheric chloride deposition (amount of chloride salts deposited from the atmosphere on a given area per unit time). 1.2 Data on atmospheric chloride deposition can be useful in classifying the corrosivity of a specific area, such as an atmospheric test site. Caution must be exercised, however, to take into consideration the season because airborne chlorides vary widely between seasons. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  10. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  11. An improved dynamic test method for solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    A comprehensive improvement of the mathematical model for the so called transfer function method is presented in this study. This improved transfer function method can estimate the traditional solar collector parameters such as zero loss coefficient and heat loss coefficient. Two new collector...... parameters t and mfCf are obtained. t is a time scale parameter which can indicate the heat transfer ability of the solar collector. mfCf can be used to calculate the fluid volume content in the solar collector or to validate the regression process by comparing it to the physical fluid volume content...... for the second-order differential term with 6–9min as the best averaging time interval. The measured and predicted collector power output of the solar collector are compared during a test of 13days continuously both for the ITF method and the QDT method. The maximum and averaging error is 53.87W/m2 and 5.22W/m2...

  12. Development of fracture toughness test method for nuclear grade graphite

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C. H.; Lee, J. S.; Cho, H. C.; Kim, D. J.; Lee, D. J. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2006-02-15

    Because of its high strength and stability at very high temperature, as well as very low thermal neutron absorption cross-section, graphite has been widely used as a structural material in Gas Cooled Reactors (GCR). Recently, many countries are developing the Very High Temperature gas cooled Reactor (VHTR) because of the potentials of hydrogen production, as well as its safety and viable economics. In VHTR, helium gas serves as the primary coolant. Graphite will be used as a reflector, moderator and core structural materials. The life time of graphite is determined from dimensional changes due to neutron irradiation, which closely relates to the changes of crystal structure. The changes of both lattice parameter and crystallite size can be easily measured by X-ray diffraction method. However, due to high cost and long time of neutron irradiation test, ion irradiation test is being performed instead in KAERI. Therefore, it is essential to develop the technique for measurement of ion irradiation damage of nuclear graphite. Fracture toughness of nuclear grade graphite is one of the key properties in the design and development of VHTR. It is important not only to evaluate the various properties of candidate graphite but also to assess the integrity of nuclear grade graphite during operation. Although fracture toughness tests on graphite have been performed in many laboratories, there have been wide variations in values of the calculated fracture toughness, due to the differences in the geometry of specimens and test conditions. Hence, standard test method for nuclear graphite is required to obtain the reliable fracture toughness values. Crack growth behavior of nuclear grade graphite shows rising R-curve which means the increase in crack growth resistance as the crack length increases. Crack bridging and microcracking have been proposed to be the dominant mechanisms of rising R-curve behavior. In this paper, the technique to measure the changes of crystallite size and

  13. 78 FR 22540 - Notice of Public Meeting/Webinar: EPA Method Development Update on Drinking Water Testing Methods...

    Science.gov (United States)

    2013-04-16

    ... AGENCY Notice of Public Meeting/Webinar: EPA Method Development Update on Drinking Water Testing Methods... in development for many CCL contaminants, with an expectation that several of these methods will...'s method development work and to provide public comments. In addition, EPA will be posting the...

  14. The Iosipescu shear test method as used for testing polymers and composite materials

    Science.gov (United States)

    Adams, Donald F.

    1990-01-01

    This paper describes a shear test method for polymers and composite materials, based on the Iosipescu (1967) shear test which was originally developed for use with homogeneous isotropic metals. Special attention is given to the loading fixture for the test, the standard specimen design and shear stress measurements. The range of the test applications is indicated. The method is in the final stages of being accepted as an ASTM standard.

  15. Distributed System Resource Racing Conditions Automated Testing Method

    Directory of Open Access Journals (Sweden)

    Robertas Jasaitis

    2013-11-01

    Full Text Available Most applications today are designed to be networked. It is natural that such applications operate on some data. Such applications are multi threaded by nature and it is a common situation when few clients are using the same application at the same time. So it is possible that those users operate with the same data. It is possible that in such an operation some data might be treated incorrectly or some client instance may operate on outdated data. In order to avoid such situations proper consistent testing should be performed. Therefore it is complicated to perform such testing manually. Automated tool which would help to solve this problem is wanted. In this paper we are presenting an automated testing method that is able to detect problems related to resource racing conditions in a distributed system.

  16. New test and characterization methods for PV modules and cells

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.; Sommeling, P. [ECN Solar Energy, Petten (Netherlands); Scholten, H. [Solland, Heerlen (Netherlands); Muller, J. [Moser-Baer, Eindhoven (Netherlands); Grossiord, N. [Holst Centre, Eindhoven (Netherlands); Smits, C.; Blanco Mantecon, M. [Holland Innovative, Eindhoven (Netherlands); Verheijen, M.; Van Berkum, J. [Philips Innovation Services, Eindhoven (Netherlands)

    2012-08-15

    The results of the project geZONd (shared facility for solar module analysis and reliability testing) are described. The project was set up by Philips, ECN, Holst, Solland, OM and T and Holland Innovative. The partners have shared most of their testing and analysis equipment for PV modules and cells, and together developed new or improved methods (including the necessary application know-how). This enables faster and more efficient innovation projects for each partner, and via commercial exploitation for other interested parties. The project has concentrated on five failure modes: corrosion, delamination, moisture ingress, UV irradiation, and mechanical bending. Test samples represented all main PV technologies: wafer based PV and rigid and flexible thin-film PV. Breakthroughs are in very early detection of corrosion, in quantitative characterization of adhesion, in-situ detection of humidity and oxygen inside modules, and ultra-fast screening of materials on UV stability.

  17. Experimental method for testing diffraction properties of reflection waveguide holograms.

    Science.gov (United States)

    Xie, Yi; Kang, Ming-Wu; Wang, Bao-Ping

    2014-07-01

    Waveguide holograms' diffraction properties include peak wavelength and diffraction efficiency, which play an important role in determining their display performance. Based on the record and reconstruction theory of reflection waveguide holograms, a novel experimental method for testing diffraction properties is introduced and analyzed in this paper, which uses a plano-convex lens optically contacted to the surface of the substrate plate of the waveguide hologram, so that the diffracted light beam can be easily detected. Then an experiment is implemented. The designed reconstruction wavelength of the test sample is 530 nm, and its diffraction efficiency is 100%. The experimental results are a peak wavelength of 527.7 nm and a diffraction efficiency of 94.1%. It is shown that the tested value corresponds well with the designed value.

  18. Standard test method for determination of resistance to staining

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method is intended to determine the resistance to staining of ceramic tile surfaces. 1.2 The resistance to staining is determined by maintaining test solutions in contact with ceramic tile surfaces for a specified period of time. After exposure, the surface is cleaned in a defined manner, and the test specimens are inspected visually for change. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Platelet function testing: methods of assessment and clinical utility.

    LENUS (Irish Health Repository)

    Mylotte, Darren

    2012-02-01

    Platelets play a central role in the regulation of both thrombosis and haemostasis yet tests of platelet function have, until recently, been exclusively used in the diagnosis and management of bleeding disorders. Recent advances have demonstrated the clinical utility of platelet function testing in patients with cardiovascular disease. The ex vivo measurement of response to antiplatelet therapies (aspirin and clopidogrel), by an ever-increasing array of platelet function tests, is with some assays, predictive of adverse clinical events and thus, represents an emerging area of interest for both the clinician and basic scientist. This review article will describe the advantages and disadvantages of the currently available methods of measuring platelet function and discuss both the limitations and emerging data supporting the role of platelet function studies in clinical practice.

  20. Platelet function testing: methods of assessment and clinical utility.

    LENUS (Irish Health Repository)

    Mylotte, Darren

    2011-01-01

    Platelets play a central role in the regulation of both thrombosis and haemostasis yet tests of platelet function have, until recently, been exclusively used in the diagnosis and management of bleeding disorders. Recent advances have demonstrated the clinical utility of platelet function testing in patients with cardiovascular disease. The ex vivo measurement of response to antiplatelet therapies (aspirin and clopidogrel), by an ever-increasing array of platelet function tests, is with some assays, predictive of adverse clinical events and thus, represents an emerging area of interest for both the clinician and basic scientist. This review article will describe the advantages and disadvantages of the currently available methods of measuring platelet function and discuss both the limitations and emerging data supporting the role of platelet function studies in clinical practice.

  1. Extended Method of Digital Modulation Recognition and Its Testing

    Directory of Open Access Journals (Sweden)

    A. Kubankova

    2011-04-01

    Full Text Available The paper describes a new method for the classification of digital modulations. ASK, 2FSK, 4FSK, MSK, BPSK, QPSK, 8PSK and 16QAM were chosen for recognition as best known digital modulations used in modern communication technologies. The maximum value of the spectral power density of the normalized-centered instantaneous amplitude of the received signal is used to discriminate between frequency modulations (2FSK, 4FSK and MSK on one hand and amplitude and phase modulations (ASK, BPSK, QPSK, 8PSK and 16QAM on the other hand. Then the 2FSK, 4FSK and MSK modulations are classified by means of spectrums. The histograms of the instantaneous phase are used to discriminate between ASK, BPSK, QPSK, 8PSK and 16QAM. The method designed was tested with simulated and measured signals corrupted by white Gaussian noise.

  2. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    Science.gov (United States)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  3. Overview of multi-input frequency domain modal testing methods with an emphasis on sine testing

    Science.gov (United States)

    Rost, Robert W.; Brown, David L.

    1988-01-01

    An overview of the current state of the art multiple-input, multiple-output modal testing technology is discussed. A very brief review of the current time domain methods is given. A detailed review of frequency and spatial domain methods is presented with an emphasis on sine testing.

  4. Standard test method for K-R curve determination

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the resistance to fracture of metallic materials under Mode I loading at static rates using either of the following notched and precracked specimens: the middle-cracked tension M(T) specimen or the compact tension C(T) specimen. A K-R curve is a continuous record of toughness development (resistance to crack extension) in terms of KR plotted against crack extension in the specimen as a crack is driven under an increasing stress intensity factor, K. 1.2 Materials that can be tested for K-R curve development are not limited by strength, thickness, or toughness, so long as specimens are of sufficient size to remain predominantly elastic to the effective crack extension value of interest. 1.3 Specimens of standard proportions are required, but size is variable, to be adjusted for yield strength and toughness of the materials. 1.4 Only two of the many possible specimen types that could be used to develop K-R curves are covered in this method. 1.5 The test is app...

  5. A SPICE Blind Test to Benchmark Global Tomographic Methods

    Science.gov (United States)

    Qin, Y.; Capdeville, Y.; Maupin, V.; Montagner, J.

    2006-12-01

    The different existing global tomographic methods result in different models of the Earth. In order to test how current imaging techniques are limited by approximations in theory and the inadequacy of data quality and coverage, we are undertaking a blind test of global inversion algorithms using complete 3D synthetic seismograms within SPICE (Seismic wave Propagation and Imaging in Complex media: a European network). First, a complex global anisotropic anelastic model has been constructed by summing the 1D reference model, deterministic and random anomalies and anisotropic crystal. This model includes 3D heterogeneities in velocity, anisotropy and attenuation at different scales in the whole mantle, as well as topography and crustal structure. In addition, the rotation and ellipticity are also included. Synthetic seismograms were generated using the Coupling Spectral Element Method with a minimum period of 32s, for a realistic distribution of 29 events and 256 stations. The synthetic seismograms have been made available to the scientific community worldwide at the IPGP website http://www.ipgp.jussieu.fr/~qyl/. Any group willing to test his tomographic technique is encouraged to download the synthetic dataset.g

  6. Alternative Testing Methods for Predicting Health Risk from Environmental Exposures

    Directory of Open Access Journals (Sweden)

    Annamaria Colacci

    2014-08-01

    Full Text Available Alternative methods to animal testing are considered as promising tools to support the prediction of toxicological risks from environmental exposure. Among the alternative testing methods, the cell transformation assay (CTA appears to be one of the most appropriate approaches to predict the carcinogenic properties of single chemicals, complex mixtures and environmental pollutants. The BALB/c 3T3 CTA shows a good degree of concordance with the in vivo rodent carcinogenesis tests. Whole-genome transcriptomic profiling is performed to identify genes that are transcriptionally regulated by different kinds of exposures. Its use in cell models representative of target organs may help in understanding the mode of action and predicting the risk for human health. Aiming at associating the environmental exposure to health-adverse outcomes, we used an integrated approach including the 3T3 CTA and transcriptomics on target cells, in order to evaluate the effects of airborne particulate matter (PM on toxicological complex endpoints. Organic extracts obtained from PM2.5 and PM1 samples were evaluated in the 3T3 CTA in order to identify effects possibly associated with different aerodynamic diameters or airborne chemical components. The effects of the PM2.5 extracts on human health were assessed by using whole-genome 44 K oligo-microarray slides. Statistical analysis by GeneSpring GX identified genes whose expression was modulated in response to the cell treatment. Then, modulated genes were associated with pathways, biological processes and diseases through an extensive biological analysis. Data derived from in vitro methods and omics techniques could be valuable for monitoring the exposure to toxicants, understanding the modes of action via exposure-associated gene expression patterns and to highlight the role of genes in key events related to adversity.

  7. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. W. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 International Energy Conservation Code (IECC) has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure (3 ACH50) for single-family and multifamily construction (in climate zones 3–8). The Leadership in Energy & Environmental Design certification program and ASHRAE Standard 189 have comparable compartmentalization requirements. ASHRAE Standard 62.2 will soon be responsible for all multifamily ventilation requirements (low rise and high rise); it has an exceptionally stringent compartmentalization requirement. These code and program requirements are driving the need for easier and more effective methods of compartmentalization in multifamily buildings.

  8. Standard Test Method for Abrasive Wear Resistance of Cemented

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of abrasive wear resistance of cemented carbides. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are in parentheses and may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard test method for using atmospheric pressure rotating cage

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a generally accepted procedure to conduct the rotating cage (RC) experiment under atmospheric pressure. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Contamination of nanoparticles by endotoxin: evaluation of different test methods

    Directory of Open Access Journals (Sweden)

    Smulders Stijn

    2012-11-01

    Full Text Available Abstract Background Nanomaterials can be contaminated with endotoxin (lipopolysaccharides, LPS during production or handling. In this study, we searched for a convenient in vitro method to evaluate endotoxin contamination in nanoparticle samples. We assessed the reliability of the commonly used limulus amebocyte lysate (LAL assay and an alternative method based on toll-like receptor (TLR 4 reporter cells when applied with particles (TiO2, Ag, CaCO3 and SiO2, or after extraction of the endotoxin as described in the ISO norm 29701. Results Our results indicate that the gel clot LAL assay is easily disturbed in the presence of nanoparticles; and that the endotoxin extraction protocol is not suitable at high particle concentrations. The chromogenic-based LAL endotoxin detection systems (chromogenic LAL assay and Endosafe-PTS, and the TLR4 reporter cells were not significantly perturbed. Conclusion We demonstrated that nanoparticles can interfere with endotoxin detection systems indicating that a convenient test method must be chosen before assessing endotoxin contamination in nanoparticle samples.

  11. Methods of Stress Testing of Financial Stability of Ukrainian Enterprises

    Directory of Open Access Journals (Sweden)

    Lukianenko Iryna G.

    2013-11-01

    Full Text Available The goal of the article lies in adaptation of the procedure of stress testing for assessment of financial stability of enterprises and development of adequate economic and mathematical instruments for its conduct. It was revealed during the study that the proposed approach allows not only obtaining a forecast assessment of financial stability in future periods of enterprise activity but also all-sided study and quantitative assessment of its reaction on action of internal and external stresses in short-term and long-term prospects. This article proves that main stages of the conduct of a stress test at the enterprise level are analysis of external environment and identification of potential markets; identification of indicators that meet the detected risks and stresses; development and specification of the economic and mathematical model, that is used for running scenarios, which should be oriented at unfavourable but quite probable events. The conducted studies confirmed prospectiveness of the use of longitudinal data models and vector auto-regression models, including error correction models when conducting stress testing at the level of the branch and an individual enterprise. The obtained results could be used as a basis for further development and improvement of the method of stress testing of financial stability of economic subjects and also for identification of the model of stress testing of individual branches of the Ukrainian economy.

  12. Standard Test Method for Laboratory Aging of Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the resistance of sandwich panels to severe exposure conditions as measured by the change in selected properties of the material after exposure. The exposure cycle to which the specimen is subjected is an arbitrary test having no correlation with natural weathering conditions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Modal decomposition method for acoustic impedance testing in square ducts.

    Science.gov (United States)

    Schultz, Todd; Cattafesta, Louis N; Sheplak, Mark

    2006-12-01

    Accurate duct acoustic propagation models are required to predict and reduce aircraft engine noise. These models ultimately rely on measurements of the acoustic impedance to characterize candidate engine nacelle liners. This research effort increases the frequency range of normal-incidence acoustic impedance testing in square ducts by extending the standard two-microphone method (TMM), which is limited to plane wave propagation, to include higher-order modes. The modal decomposition method (MDM) presented includes four normal modes in the model of the sound field, thus increasing the bandwidth from 6.7 to 13.5 kHz for a 25.4 mm square waveguide. The MDM characterizes the test specimen for normal- and oblique-incident acoustic impedance and mode scattering coefficients. The MDM is first formulated and then applied to the measurement of the reflection coefficient matrix for a ceramic tubular specimen. The experimental results are consistent with results from the TMM for the same specimen to within the 95% confidence intervals for the TMM. The MDM results show a series of resonances for the ceramic tubular material exhibiting a monotonic decrease in the resonant peaks of the acoustic resistance with increasing frequency, resembling a rigidly-terminated viscous tube, and also evidence of mode scattering is visible at the higher frequencies.

  14. Test Methods for Telemetry Systems and Subsystems. Volume 5: Test Methods for Digital Recorder/Reproducer Systems and Recorder Memory Modules

    Science.gov (United States)

    2016-09-26

    Telemetry Group Document 118-16 (Volume V) TEST METHODS FOR TELEMETRY SYSTEMS AND SUBSYSTEMS VOLUME V TEST METHODS FOR DIGITAL RECORDER ...AND SUBSYSTEMS VOLUME V TEST METHODS FOR DIGITAL RECORDER /REPRODUCER SYSTEMS AND RECORDER MEMORY MODULES September 2016...parameters of digital recorder systems and recorder memory modules, to test compatibility and standard compliance, and to increase interoperability

  15. Agar dilution method for susceptibility testing of Neisseria gonorrhoeae

    Directory of Open Access Journals (Sweden)

    Marta C de Castillo

    1996-12-01

    Full Text Available The antibiotic susceptibilities of Neisseria gonorrhoeae isolates obtained from patients attending a clinic for sexually transmitted diseases in Tucumán, Argentina, were determined by the agar dilution method (MIC. 3.5% of the isolates produced ²-lactamase. A total of 96.5% of ²-lactamase negative isolates tested were susceptible to penicillin (MIC < 2 µgml-1; 14.03% of the tested isolates were resistant to tetracycline (MIC < 2 µgml-1, and 98% of the tested isolates were susceptible to spectinomycin (MIC < 64 µgml-1. The MICs for 95% of the isolates, tested for other drugs were: < 2 µgml-1 for cefoxitin, < 0.06 µgml-1 for cefotaxime, < 0.25 µgml-1 for norfloxacin, < 10 µgml-1 for cephaloridine, < 10 µgml-1 for cephalexin, and < 50 µgml-1 for kanamycin. Antibiotic resistance among N. gonorrhoeae isolates from Tucumán, Argentina, appeared to be primarily limited to penicillin and tetracycline, which has been a general use against gonorrhoeae in Tucumán since 1960. Periodic monitoring of the underlying susceptibility profiles of the N. gonorrhoeae strains prevalent in areas of frequent transmission may provide clues regarding treatment options and emerging of drug resistance.

  16. Verification and application of the Iosipescu shear test method

    Science.gov (United States)

    Walrath, D. E.; Adams, D. F.

    1984-01-01

    Finite element models were used to study the effects of notch angle variations on the stress state within an Iosipescu shear test speciment. These analytical results were also studied to determine the feasibility of using strain gage rosettes and a modified extensometer to measure shear strains in this test specimen. Analytical results indicate that notch angle variations produced only small differences in simulated shear properties. Both strain gage rosettes and the modified extensometer were shown to be feasible shear strain transducers for the test method. The Iosipoescu shear test fixture was redesigned to incorporate several improvements. These improvements include accommodation of a 50 percent larger specimen for easier measurement of shear train, a clamping mechanism to relax strict tolerances on specimen width, and a self contained alignment tool for use during specimen installation. A set of in-plane and interlaminar shear properties were measured for three graphite fabric/epoxy composites of T300/934 composite material. The three weave patterns were Oxford, 5-harness satin, and 8-harness satin.

  17. PMD test method in the fiber link with optical amplifier

    Science.gov (United States)

    Li, Tangjun; Wang, Muguang; Gong, Xiangfeng; Diao, Cao; Tong, Zhi; Wei, Hui; Jian, Shuisheng

    2005-02-01

    To learn the surrounding conditions in the fiber link and its effect on PMD, and to provide the first-hand design basis, we have carried out the data observation of PMD in a fiber link for a long time. We have tested the first-order and second-order PMD. The fiber tested is the G652 fiber produced by Corning Co. of USA, and the testing distance is 1000km; n segments of same fibers are linked into one, and n equals to 40, that is to say, the length of every segment is 25km; for the requirement of dispersion compensation in the high-speed and long distance fiber optical communication system, one fiber grating dispersion compensator is added in the place of every 200km, and there are five compensators; one EDFA is added in the place of every 100km, and there are eleven EDFA. The result suggests that, with the increase of length of fiber link, the distribution of PMD intends to be stable, that is, with the number n increasing, the relative error of PMD becomes less. The testing methods are the Jones matrix eigenanalysis technique and interference technique. HP8509B fiber polarization analyzer of Agilent in USA is used for measuring instrument of the Jones matrix eigenanalysis technique; FPMD-5600 Femtosecond PMD Analyzer of EXFO in Canada is used for measuring instrument of interference technique. The difference between these two testing methods is analyzed. With the Jones matrix eigenanalysis technique, fibers of 1000km are inspected through 48 hours, and the result suggests that, at nine o'clock in the morning, PMD reaches the maximum, at nine o'clock in the evening, it reaches the minimum, during other time, its change is very little. So it can be concluded that, PMD in the long distance fiber link is affected by temperature of the lab. Stress testing is carried in the ultra-short fiber (less than one meter). PMD has no obvious change in the range of stress which can be endured by the fiber.

  18. Electric vehicle chassis dynamometer test methods at JPL and their correlation to track tests

    Science.gov (United States)

    Marte, J.; Bryant, J.

    1983-01-01

    Early in its electric vehicle (EV) test program, JPL recognized that EV test procedures were too vague and too loosely defined to permit much meaningful data to be obtained from the testing. Therefore, JPL adopted more stringent test procedures and chose the chassis dynamometer rather than the track as its principal test technique. Through the years, test procedures continued to evolve towards a methodology based on chassis dynamometers which would exhibit good correlation with track testing. Based on comparative dynamometer and track test results on the ETV-1 vehicle, the test methods discussed in this report demonstrate a means by which excellent track-to-dynamometer correlation can be obtained.

  19. VALIDATION OF THE ASSR TEST THROUGH COMPLEMENTARY AUDIOLOGYICAL METHODS

    Directory of Open Access Journals (Sweden)

    C. Mârtu

    2016-04-01

    Full Text Available Introduction: Auditory Steady State Response (ASSR is an objective method for determining the auditive threshold, applicable and necessary especially in children. The test is extremely important for recommending cochlear implant in children. The aim of the study was to compare pure tone audiometry responses and auditory steady-state thresholds. Materials and method: The study was performed on a group including both patients with normal hearing and with hearing loss. The main inclusion criteria accepted only patients with normal otomicroscopic aspect, normal tympanogram, capable to respond to pure tone audiometry, and with ear conduction thresholds between 0 and 80 dB NHL. The patients with suppurative otic processes or ear malformations were excluded. The research protocol was followed, the tests being performed in soundproofed rooms, starting with pure tone audiometry followed, after a pause, by ASSR determinations at frequencies of 0.5, 1.2 and 4 KHz. The audiological instruments were provided by a single manufacturer. ASSR was recorded at least two times for both borderline intensities, namely the one defining the auditory threshold and the first no-response intensity. The recorded responses were stored in a database and further processed in Excel. Discussion: The differences observed between pure tone audiometry and ASSR thresholds are important at 500 Hz and insignificant at the other frequencies. When approaching the PTA-ASSR relation, whatever the main characteristic between the PTA and ASSR thresholds in one ear, the profile of the lines gap maintains the same shape on the opposite ear. Conclusions: ASSR is a confident objective test, maintaining attention to low frequencies, where some differences might occur.

  20. Expedient methods of respiratory protection. II. Leakage tests. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, D.W.; Hinds, W.C.; Price, J.M.; Weker, R.; Yee, H.S.

    1983-07-01

    The following readily-available materials were tested on a manikin connected to a breathing simulator to determine the fraction of an approximately 2-..mu..m-diameter aerosol that would leak around the seal of the materials to the manikin's face: cotton/polyester shirt material, cotton handkerchief material, toweling (a wash cloth), a surgical mask (Johnson and Johnson Co., model HRI 8137), and a NIOSH-approved disposable face mask (3M, model number 8710). The leakage tests were performed to supplement the measurements of penetration through the materials, conducted as the first phase of this investigation. The leakage tests were performed with the materials held on to the face by three methods, leakage fractions being determined from comparisons with the penetration of the same aerosol for the materials fully taped to the face. At a breathing rate of 37 liters per minute, mean leakages ranged from 0.0 percent to 63 percent. Mean penetrations exclusive of leakage ranged from 0.6 percent to 39 percent. Use of nylon hosiery material (panty hose) to hold the handkerchief material or the disposable face mask to the face was found to be very effective in preventing leakage. Such a combination could be expected to reduce leakage around the handkerchief to about ten percent or less in practice, and around the mask to less than one percent, offering substantial protection from accidentally generated aerosols. The reduction in leakage around the mask provided by the hosiery material suggests the adaptation and use of such an approach in regular industrial hygiene practice. The third and final phase of this investigation is underway, in which the penetration of the materials by particles with diameters between 0.05 and 0.5 ..mu..m is being measured and the effectiveness of the methods for dose reduction in the presence of radioactive aerosols is being modeled.

  1. Polygraph Test Results Assessment by Regression Analysis Methods

    Directory of Open Access Journals (Sweden)

    K. A. Leontiev

    2014-01-01

    Full Text Available The paper considers a problem of defining the importance of asked questions for the examinee under judicial and psychophysiological polygraph examination by methods of mathematical statistics. It offers the classification algorithm based on the logistic regression as an optimum Bayesian classifier, considering weight coefficients of information for the polygraph-recorded physiological parameters with no condition for independence of the measured signs.Actually, binary classification is executed by results of polygraph examination with preliminary normalization and standardization of primary results, with check of a hypothesis that distribution of obtained data is normal, as well as with calculation of coefficients of linear regression between input values and responses by method of maximum likelihood. Further, the logistic curve divided signs into two classes of the "significant" and "insignificant" type.Efficiency of model is estimated by means of the ROC analysis (Receiver Operator Characteristics. It is shown that necessary minimum sample has to contain results of 45 measurements at least. This approach ensures a reliable result provided that an expert-polygraphologist possesses sufficient qualification and follows testing techniques.

  2. Standard Test Method for Thermal Oxidative Resistance of Carbon Fibers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the apparatus and procedure for the determination of the weight loss of carbon fibers, exposed to ambient hot air, as a means of characterizing their oxidative resistance. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units which are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard information, see Section 8.

  3. New prior sampling methods for nested sampling - Development and testing

    Science.gov (United States)

    Stokes, Barrie; Tuyl, Frank; Hudson, Irene

    2017-06-01

    Nested Sampling is a powerful algorithm for fitting models to data in the Bayesian setting, introduced by Skilling [1]. The nested sampling algorithm proceeds by carrying out a series of compressive steps, involving successively nested iso-likelihood boundaries, starting with the full prior distribution of the problem parameters. The "central problem" of nested sampling is to draw at each step a sample from the prior distribution whose likelihood is greater than the current likelihood threshold, i.e., a sample falling inside the current likelihood-restricted region. For both flat and informative priors this ultimately requires uniform sampling restricted to the likelihood-restricted region. We present two new methods of carrying out this sampling step, and illustrate their use with the lighthouse problem [2], a bivariate likelihood used by Gregory [3] and a trivariate Gaussian mixture likelihood. All the algorithm development and testing reported here has been done with Mathematica® [4].

  4. Time Triggered Ethernet System Testing Means and Method

    Science.gov (United States)

    Smithgall, William Todd (Inventor); Hall, Brendan (Inventor); Varadarajan, Srivatsan (Inventor)

    2014-01-01

    Methods and apparatus are provided for evaluating the performance of a Time Triggered Ethernet (TTE) system employing Time Triggered (TT) communication. A real TTE system under test (SUT) having real input elements communicating using TT messages with output elements via one or more first TTE switches during a first time interval schedule established for the SUT. A simulation system is also provided having input simulators that communicate using TT messages via one or more second TTE switches with the same output elements during a second time interval schedule established for the simulation system. The first and second time interval schedules are off-set slightly so that messages from the input simulators, when present, arrive at the output elements prior to messages from the analogous real inputs, thereby having priority over messages from the real inputs and causing the system to operate based on the simulated inputs when present.

  5. Biological test method: Acute test for sediment toxicity using marine or estuarine amphipods

    National Research Council Canada - National Science Library

    McLeay, D. J; Sprague, John B

    1992-01-01

    Methods recommended by Environment Canada for performing 10-day tests for sediment toxicity, using one or more of the following species of marine or estuarine sediment-burrowing amphipods, are described in this report...

  6. Variable Depth Bragg Peak Method for Single Event Effects Testing

    Science.gov (United States)

    Buchner, S.; Kanyogoro, N.; Foster, C.; O'Neill, P.

    2011-01-01

    Traditionally, accelerator SEE testing is accomplished by removing the tops of packages so that the IC chips are accessible to heavy ions. However, ICs in some advanced packages cannot be de-lidded so a different approach is used that involves grinding and/or chemically etching away part of the package and the chip from the back side. The parts are then tested from the back side with ions having sufficient range to reach the sensitive volume. More recently, the entire silicon substrate in an SOI/SRAM was removed, making it possible to use low-energy ions with shorter ranges. Where removal of part of the package is not possible, facilities at Michigan State, NASA Space Radiation Laboratory, GANIL (France) and GSI (Germany) offer high-energy heavy ions with long ranges so that the ions can reach the devices' sensitive volumes without much change in the LET. Unfortunately, a run will typically involve only one ion species having a single energy and LET due to the long time it takes to tune a new energy. The Variable Depth Bragg Peak (VDBP) method is similar to the above method in that it involves the use of high-energy heavy ions that are able to pass through the packaging material and reach the device, obviating the need to remove the package. However, the method provides a broad range of LETs from a single ion by inserting degraders in the beam that modify the ion energy and, therefore, the LET. The crux of the method involves establishing a fiduciary point for degrader thickness, i.e., where the Bragg peak is located precisely at the sensitive volume in the device, for which the measured SEU cross-section and the ion LET are both also maxima and can be calculated using a Monte-Carlo program, TRIM. Once the fiduciary point has been established, calibrated high density polyethylene (HDPE) degraders are inserted into or removed from the beam to vary the ion LET at the device in a known manner. After each change of degrader thickness, the SEU cross-section is measured

  7. 40 CFR 63.750 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... cleaning solvent and shall demonstrate that one of the approved composition definitions is met. (b) Vapor... electrostatic spray application methods. (2)(i) For the process or processes for which the alternative... electrostatic spray application methods shall be used. The emissions shall be determined based on the volumes...

  8. Ultrasonic and advanced methods for nondestructive testing and material characterization

    National Research Council Canada - National Science Library

    Chen, C. H

    2007-01-01

    ... and physics among others. There are at least two dozen NDT methods in use. In fact any sensor that can examine the inside of material nondestructively is useful for NDT. However the ultrasonic methods are still most popular because of its capability, flexibility, and relative cost effectiveness. For this reason this book places a heavy emphasis...

  9. Standard test method for evaluating springback of sheet metal using the demeri split ring test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method provides a means of evaluating the springback behavior of metals in a test that simulates a stretch-draw forming process. The test method can also be used to calibrate computer simulation codes by selecting appropriate control parameters to achieve satisfactory correlation between simulation and test results. 1.2 The values stated in SI units are standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard test methods for notched bar impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods describe notched-bar impact testing of metallic materials by the Charpy (simple-beam) test and the Izod (cantilever-beam) test. They give the requirements for: test specimens, test procedures, test reports, test machines (see Annex A1) verifying Charpy impact machines (see Annex A2), optional test specimen configurations (see Annex A3), precracking Charpy V-notch specimens (see Annex A4), designation of test specimen orientation (see Annex A5), and determining the percent of shear fracture on the surface of broken impact specimens (see Annex A6). In addition, information is provided on the significance of notched-bar impact testing (see Appendix X2), methods of measuring the center of strike (see Appendix X2). 1.2 These test methods do not address the problems associated with impact testing at temperatures below -196 C (-320 F, 77 K). 1.3 The values stated in SI units are to be regarded as the standard. Inch-pound units are provided for information only. This standard does not purpor...

  11. A Biochar Classification System and Associated Test Methods

    Energy Technology Data Exchange (ETDEWEB)

    Camps-Arbestain, Marta; Amonette, James E.; Singh, Balwant; Wang, Tao; Schmidt, Hans-Peter

    2015-02-18

    In this chapter, a biochar classification system related to its use as soil amendment is proposed. This document builds upon previous work and constrains its scope to materials with properties that satisfy the criteria for biochar as defined by either the International Biochar Initiative (IBI) Biochar Standards or the European Biochar Community (EBC) Standards, and it is intended to minimise the need for testing in addition to those required according to the above-mentioned standards. The classification system envisions enabling stakeholders and commercial entities to (i) identify the most suitable biochar to fulfil the requirements for a particular soil and/or land-use, and (ii) distinguish the application of biochar for specific niches (e.g., soilless agriculture). It is based on the best current knowledge and the intention is to periodically review and update the document based on new data and knowledge that become available in the scientific literature. The main thrust of this classification system is based on the direct or indirect beneficial effects that biochar provides from its application to soil. We have classified the potential beneficial effects of biochar application to soils into five categories with their corresponding classes, where applicable: (i) carbon (C) storage value, (ii) fertiliser value, (iii) liming value, (iv) particle-size, and (v) use in soil-less agriculture. A summary of recommended test methods is provided at the end of the chapter.

  12. Development and testing of improved statistical wind power forecasting methods.

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, J.; Bessa, R.J.; Keko, H.; Sumaili, J.; Miranda, V.; Ferreira, C.; Gama, J.; Botterud, A.; Zhou, Z.; Wang, J. (Decision and Information Sciences); (INESC Porto)

    2011-12-06

    (with spatial and/or temporal dependence). Statistical approaches to uncertainty forecasting basically consist of estimating the uncertainty based on observed forecasting errors. Quantile regression (QR) is currently a commonly used approach in uncertainty forecasting. In Chapter 3, we propose new statistical approaches to the uncertainty estimation problem by employing kernel density forecast (KDF) methods. We use two estimators in both offline and time-adaptive modes, namely, the Nadaraya-Watson (NW) and Quantilecopula (QC) estimators. We conduct detailed tests of the new approaches using QR as a benchmark. One of the major issues in wind power generation are sudden and large changes of wind power output over a short period of time, namely ramping events. In Chapter 4, we perform a comparative study of existing definitions and methodologies for ramp forecasting. We also introduce a new probabilistic method for ramp event detection. The method starts with a stochastic algorithm that generates wind power scenarios, which are passed through a high-pass filter for ramp detection and estimation of the likelihood of ramp events to happen. The report is organized as follows: Chapter 2 presents the results of the application of ITL training criteria to deterministic WPF; Chapter 3 reports the study on probabilistic WPF, including new contributions to wind power uncertainty forecasting; Chapter 4 presents a new method to predict and visualize ramp events, comparing it with state-of-the-art methodologies; Chapter 5 briefly summarizes the main findings and contributions of this report.

  13. A Method to Test Model Calibration Techniques: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, Ron; Polly, Ben; Neymark, Joel

    2016-09-01

    This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

  14. [Statistical tests in medical research: traditional methods vs. multivariate NPC permutation tests].

    Science.gov (United States)

    Arboretti, Rosa; Bordignon, Paolo; Corain, Livio; Palermo, Giuseppe; Pesarin, Fortunato; Salmaso, Luigi

    2015-01-01

    Statistical tests in medical research: traditional methods vs. multivariate npc permutation tests.Within medical research, a useful statistical tool is based on hypotheses testing in terms of the so-called null, that is the treatment has no effect, and alternative hypotheses, that is the treatment has some effects. By controlling the risks of wrong decisions, empirical data are used in order to possibly reject the null hypotheses in favour of the alternative, so that demonstrating the efficacy of a treatment of interest. The multivariate permutation tests, based on the nonparametric combination - NPC method, provide an innovative, robust and effective hypotheses testing solution to many real problems that are commonly encountered in medical research when multiple end-points are observed. This paper discusses the various approaches to hypothesis testing and the main advantages of NPC tests, which consist in the fact that they require much less stringent assumptions than traditional statistical tests. Moreover, the related results may be extended to the reference population even in case of selection-bias, that is non-random sampling. In this work, we review and discuss some basic testing procedures along with the theoretical and practical relevance of NPC tests showing their effectiveness in medical research. Within the non-parametric methods, NPC tests represent the current "frontier" of statistical research, but already widely available in the practice of analysis of clinical data.

  15. Testing an Automated Accuracy Assessment Method on Bibliographic Data

    Directory of Open Access Journals (Sweden)

    Marlies Olensky

    2014-12-01

    Full Text Available This study investigates automated data accuracy assessment as described in data quality literature for its suitability to assess bibliographic data. The data samples comprise the publications of two Nobel Prize winners in the field of Chemistry for a 10-year-publication period retrieved from the two bibliometric data sources, Web of Science and Scopus. The bibliographic records are assessed against the original publication (gold standard and an automatic assessment method is compared to a manual one. The results show that the manual assessment method reflects truer accuracy scores. The automated assessment method would need to be extended by additional rules that reflect specific characteristics of bibliographic data. Both data sources had higher accuracy scores per field than accumulated per record. This study contributes to the research on finding a standardized assessment method of bibliographic data accuracy as well as defining the impact of data accuracy on the citation matching process.

  16. Antimicrobial Testing Methods & Procedures: MB-32-00

    Science.gov (United States)

    Information about ATMP - SOP Quantitative Petri Plate Method (QPM) for Determining the Effectiveness of Antimicrobial Towelettes Against Spores of Clostridium difficile (ATCC 43598) on Inanimate, Hard Non-porous Surfaces - MB-32-00

  17. COMPARATION BETWEEN NONDESTRUCTIVE TESTING METHODS FOR THE ALUMINIUM BRAZED PIECES

    Directory of Open Access Journals (Sweden)

    Dan NIŢOI

    2014-05-01

    Full Text Available Presented paper refers to different control methods used in aluminium brazed joining because of possible defects. Low joining complexity permits exact damages position in relation with materials geometry.

  18. 40 CFR 63.805 - Performance test methods.

    Science.gov (United States)

    2010-07-01

    ... acceptance under part 63, appendix A, Method 301. (3) Operate the control device with all affected emission... makeup air ducts and all exhaust ducts are constructed so that the volumetric flow rate in each can be...

  19. Linear shrinkage test: justification for its reintroduction as a standard South African test method

    CSIR Research Space (South Africa)

    Sampson, LR

    2009-06-04

    Full Text Available Several problems with the linear shrinkage test specified in Method A4 of the THM 1 1979 were addressed as part of this investigation in an effort to improve the alleged poor reproducibility of the test and justify its reintroduction into THM 1. A...

  20. A method of rapid testing of radioactivity of different materials

    Directory of Open Access Journals (Sweden)

    Yu. Zabulonov

    2016-10-01

    Full Text Available A new method for the detection of low-level ionising radiation in solid, liquid or loose materials, which is based on the use of the Bayesian approach for the estimation of probabilistic parameters and a special statistical criterion, is offered in the present paper. We describe the algorithm and show the advantages of the method. The approach can be effective even in the case of extremely low signals whose intensity is much less than the background radiation.

  1. Geophysical Methods for Non-Destructive Testing in Civil Engineering

    Science.gov (United States)

    Niederleithinger, E.

    2013-12-01

    Many non-destructive testing (NDT) methods for civil engineering (e. g. ultrasonics, radar) are similar to geophysical techniques. They just differ in scale, material under investigation and vocabulary used. In spite of the fact that the same principles of physics and mathematics apply to both fields, exchange has been limited in the past. But since a few years more and more geophysical knowledge is used in civil engineering. One of the focal points in research is to improve ultrasonic testing of concrete to be able to image the inside even of large, complex structures and to detect any deterioration as early as possible. One of the main issues is the heterogeneity of concrete, including aggregates, reinforcement, cracks and many other features. Our current research focuses on three points. One is the application of state of the art geophysical migration techniques as Reverse Time Migration (RTM) to image vertical faces or the backside of voids and ducts in thick concrete structures, which isn't possible with conventional techniques used in NDT. Second, we have started to use seismic interferometric techniques to interpolate ultrasonic traces, which can't be measured directly for technical reasons. Third, we are using coda wave interferometry to detect concrete degradation due to load, fatigue, temperature or other influences as early as possible. Practical examples of the application of these techniques are given and potential future research directions will be discussed. It will be shown, how a subset of these techniques can be used for innovative monitoring systems for civil infrastructure. Imaging the interior of a concrete body by ultrasonics and reverse time migration(simulated data).

  2. Statistical methods used to test for agreement of medical instruments measuring continuous variables in method comparison studies: a systematic review.

    Science.gov (United States)

    Zaki, Rafdzah; Bulgiba, Awang; Ismail, Roshidi; Ismail, Noor Azina

    2012-01-01

    Accurate values are a must in medicine. An important parameter in determining the quality of a medical instrument is agreement with a gold standard. Various statistical methods have been used to test for agreement. Some of these methods have been shown to be inappropriate. This can result in misleading conclusions about the validity of an instrument. The Bland-Altman method is the most popular method judging by the many citations of the article proposing this method. However, the number of citations does not necessarily mean that this method has been applied in agreement research. No previous study has been conducted to look into this. This is the first systematic review to identify statistical methods used to test for agreement of medical instruments. The proportion of various statistical methods found in this review will also reflect the proportion of medical instruments that have been validated using those particular methods in current clinical practice. Five electronic databases were searched between 2007 and 2009 to look for agreement studies. A total of 3,260 titles were initially identified. Only 412 titles were potentially related, and finally 210 fitted the inclusion criteria. The Bland-Altman method is the most popular method with 178 (85%) studies having used this method, followed by the correlation coefficient (27%) and means comparison (18%). Some of the inappropriate methods highlighted by Altman and Bland since the 1980s are still in use. This study finds that the Bland-Altman method is the most popular method used in agreement research. There are still inappropriate applications of statistical methods in some studies. It is important for a clinician or medical researcher to be aware of this issue because misleading conclusions from inappropriate analyses will jeopardize the quality of the evidence, which in turn will influence quality of care given to patients in the future.

  3. Test report for cesium powder and pellets inner container decontamination method determination test

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, D.L.

    1998-08-17

    This report documents the decontamination method determination testing that was performed on three cesium powder and pellets inner container test specimens The test specimens were provided by B and W Hanford Company (BVMC). The tests were conducted by the Numatec Hanford Company (NHC), in the 305 Building. Photographic evidence was also provided by NHC. The Test Plan and Test Report were provided by Waste Management Federal Services, Inc., Northwest Operations. Witnesses to testing included a test engineer, a BC project engineer, and a BC Quality Assurance (QA) representative. The Test Plan was modified with the mutual decision of the test engineer, the BWHC project engineer, and the BVMC QA representative. The results of this decision were written in red (permanent type) ink on the official copy of the test procedure, Due to the extent of the changes, a summary of the test results are provided in Section 3.0 of this Test Report. In addition, a copy of the official copy field documentation obtained during testing is included in Appendix A. The original Test Plan (HNF-2945) will be revised to indicate that extensive changes were required in the field during testing, however, the test documentation will stand as is (i.e., it will not be retyped, text shaded, etc.) due to the inclusion of the test parameters and results into this Test Report.

  4. A new method of sweat testing: the CF Quantum®sweat test.

    Science.gov (United States)

    Rock, Michael J; Makholm, Linda; Eickhoff, Jens

    2014-09-01

    Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland-Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97-0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94-100%) and 96% (95% confidence interval: 89-99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%) (p sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  5. Breath testing as a method for detecting lung cancer.

    Science.gov (United States)

    Taivans, Immanuels; Bukovskis, Maris; Strazda, Gunta; Jurka, Normunds

    2014-02-01

    Early diagnosis of lung cancer is important due to high mortality in late stages of the disease. An ideal approach for population screening could be the breath analysis, due to its non-invasiveness, simplicity and cheapness. Using sensitive methods of analysis like gas chromatography/mass spectrometry in exhaled air of cancer patients were discovered some volatile organic compounds - possible candidates for cancer markers. However, these compounds were not specific for cancer cells. At the same time, integrative approaches used to analyze the exhaled breath have demonstrated high sensitivity and specificity of this method for lung cancer diagnosis. Such integrative approaches include detection of smell prints by electronic nose or integrated analysis of wide range of volatile organic compounds detected by gas chromatography/mass spectrometry or related methods. Modern statistical pattern recognition systems like logistic regression analysis, support vector machine or analysis by artificial neuronal network may improve diagnostic accuracy.

  6. 40 CFR 60.485 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ...” at 25 °C and 760 mm Hg (77 °F and 14.7 psi), kcal/g-mole (5) Method 18 or ASTM D6420-99 (2004) (where... procedures shall be used: (1) Procedures that conform to the general methods in ASTM E260-73, 91, or 96, E168... 0.3 kPa at 20 °C (1.2 in. H2O at 68 °F). Standard reference texts or ASTM D2879-83, 96, or 97...

  7. Proposed test method for determining discharge rates from water closets

    DEFF Research Database (Denmark)

    Nielsen, V.; Fjord Jensen, T.

    At present the rates at which discharge takes place from sanitary appliances are mostly known only in the form of estimated average values. SBI has developed a measuring method enabling determination of the exact rate of discharge from a sanitary appliance as function of time. The methods depends...... on the application of a calibrated measuring vessel, the volume of water in the vessel being measured at a given moment by means of a transducer and recorded by an UV recorder which is able to follow very rapid variations. In the article the apparatus is described in detail, and an example is given...

  8. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  9. RAPID TEST METHOD FOR EVALUATION OF ANTIFREEZE ADDITIVE EFFICIENCY

    Directory of Open Access Journals (Sweden)

    S. V. Gushchin

    2015-01-01

    Full Text Available Usage of chemical additives while executing concrete works at negative temperatures is considered as a convenient and economical method. Range of the used antifreeze additives is rather wide. A great number of new additives are advertised but their characteristics have not been practically studied. Evaluation of the antifreeze additive efficiency is unfortunately rather long process and it does not provide comprehensive data on concrete structure formation processes. Due to this development of rapid and comprehensive methodology for construction companies is urgently required.Freezing processes of antifreeze additive aqueous solutions and hardening of cement paste with them have been investigated in the paper. The paper proposes a methodology for determination of freezing point for aqueous solutions of chemical additives of various applications. Identity of  freezing point for a chemical additive aqueous solution and cement paste with an equal concentration of the additive in the paste pore fluid has been determined while taking  calcium nitrate and sodium formate additives as an example. The paper demonstrates the possibility to evaluate efficiency of antifreeze additive action on the basis of kinetics in temperature changes of the cement paste with additives by its consecutive freezing and defrosting.  A methodology for operational evaluation in the field of chemical additive application for concreting items at negative temperatures has been offered in the paper.  The methodology does not require  deficient and expensive test-equipment. It can be applied at ordinary construction companies and it is comprehensible for personnel of low-qualification.  The paper shows the possibility to develop an original methodology for designing concrete structure which is based on operating efficiency determinations  for single and integrated antifreeze additives.

  10. Nondestructive testing of adhesive bonds by nuclear quadrupole resonance method

    Science.gov (United States)

    Hewitt, R. R.

    1971-01-01

    Inert, strain sensitive tracer, cuprous oxide, added to polymeric adhesive ensures sufficiently large signal to noise ratio in NQR system output. Method is successful, provided that RF-transparent structural materials are used between modified adhesive and probe of NQR spectrometer.

  11. 40 CFR 60.166 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ...) The owner or operator shall determine compliance with the particulate matter, sulfur dioxide (SO2) and... determine the particulate matter concentration. The sampling time and sample volume for each run shall be at... monitoring system drift during the run may not exceed 2 percent of the span value. (3) Method 9 and the...

  12. A retrospective approach to testing the DNA barcoding method.

    Directory of Open Access Journals (Sweden)

    David G Chapple

    Full Text Available A decade ago, DNA barcoding was proposed as a standardised method for identifying existing species and speeding the discovery of new species. Yet, despite its numerous successes across a range of taxa, its frequent failures have brought into question its accuracy as a short-cut taxonomic method. We use a retrospective approach, applying the method to the classification of New Zealand skinks as it stood in 1977 (primarily based upon morphological characters, and compare it to the current taxonomy reached using both morphological and molecular approaches. For the 1977 dataset, DNA barcoding had moderate-high success in identifying specimens (78-98%, and correctly flagging specimens that have since been confirmed as distinct taxa (77-100%. But most matching methods failed to detect the species complexes that were present in 1977. For the current dataset, there was moderate-high success in identifying specimens (53-99%. For both datasets, the capacity to discover new species was dependent on the methodological approach used. Species delimitation in New Zealand skinks was hindered by the absence of either a local or global barcoding gap, a result of recent speciation events and hybridisation. Whilst DNA barcoding is potentially useful for specimen identification and species discovery in New Zealand skinks, its error rate could hinder the progress of documenting biodiversity in this group. We suggest that integrated taxonomic approaches are more effective at discovering and describing biodiversity.

  13. A Retrospective Approach to Testing the DNA Barcoding Method

    Science.gov (United States)

    Chapple, David G.; Ritchie, Peter A.

    2013-01-01

    A decade ago, DNA barcoding was proposed as a standardised method for identifying existing species and speeding the discovery of new species. Yet, despite its numerous successes across a range of taxa, its frequent failures have brought into question its accuracy as a short-cut taxonomic method. We use a retrospective approach, applying the method to the classification of New Zealand skinks as it stood in 1977 (primarily based upon morphological characters), and compare it to the current taxonomy reached using both morphological and molecular approaches. For the 1977 dataset, DNA barcoding had moderate-high success in identifying specimens (78-98%), and correctly flagging specimens that have since been confirmed as distinct taxa (77-100%). But most matching methods failed to detect the species complexes that were present in 1977. For the current dataset, there was moderate-high success in identifying specimens (53-99%). For both datasets, the capacity to discover new species was dependent on the methodological approach used. Species delimitation in New Zealand skinks was hindered by the absence of either a local or global barcoding gap, a result of recent speciation events and hybridisation. Whilst DNA barcoding is potentially useful for specimen identification and species discovery in New Zealand skinks, its error rate could hinder the progress of documenting biodiversity in this group. We suggest that integrated taxonomic approaches are more effective at discovering and describing biodiversity. PMID:24244283

  14. A Hybrid Positioning Method Based on Hypothesis Testing

    DEFF Research Database (Denmark)

    Amiot, Nicolas; Pedersen, Troels; Laaraiedh, Mohamed

    2012-01-01

    We consider positioning in the scenario where only two reliable range estimates, and few less reliable power observations are available. Such situations are difficult to handle with numerical maximum likelihood methods which require a very accurate initialization to avoid being stuck into local m...

  15. On estimation methods and test for proportional hazards ...

    African Journals Online (AJOL)

    This work compared three estimation methods to handle tied survival time data under the semiparametric Cox proportional hazards model framework (the Exact, Breslow and Efron partial likelihood) and also two parametric proportional hazards models (the Exponential and Weibull) which utilized full likelihood estimation ...

  16. An entrepreneurial physics method and its experimental test

    Science.gov (United States)

    Brown, Robert

    2012-02-01

    As faculty in a master's program for entrepreneurial physics and in an applied physics PhD program, I have advised upwards of 40 master and doctoral theses in industrial physics. I have been closely involved with four robust start-up manufacturing companies focused on physics high-technology and I have spent 30 years collaborating with industrial physicists on research and development. Thus I am in a position to reflect on many articles and advice columns centered on entrepreneurship. What about the goals, strategies, resources, skills, and the 10,000 hours needed to be an entrepreneur? What about business plans, partners, financing, patents, networking, salesmanship and regulatory affairs? What about learning new technology, how to solve problems and, in fact, learning innovation itself? At this point, I have my own method to propose to physicists in academia for incorporating entrepreneurship into their research lives. With this method, we do not start with a major invention or discovery, or even with a search for one. The method is based on the training we have, and the teaching we do (even quantum electrodynamics!), as physicists. It is based on the networking we build by 1) providing courses of continuing education for people working in industry and 2) through our undergraduate as well as graduate students who have gone on to work in industry. In fact, if we were to be limited to two words to describe the method, they are ``former students.'' Data from local and international medical imaging manufacturing industry are presented.

  17. Well test imaging - a new method for determination of boundaries from well test data

    Energy Technology Data Exchange (ETDEWEB)

    Slevinsky, B.A.

    1997-08-01

    A new method has been developed for analysis of well test data, which allows the direct calculation of the location of arbitrary reservoir boundaries which are detected during a well test. The method is based on elements of ray tracing and information theory, and is centered on the calculation of an instantaneous {open_quote}angle of view{close_quote} of the reservoir boundaries. In the absence of other information, the relative reservoir shape and boundary distances are retrievable in the form of a Diagnostic Image. If other reservoir information, such as 3-D seismic, is available; the full shape and orientation of arbitrary (non-straight line or circular arc) boundaries can be determined in the form of a Reservoir Image. The well test imaging method can be used to greatly enhance the information available from well tests and other geological data, and provides a method to integrate data from multiple disciplines to improve reservoir characterization. This paper covers the derivation of the analytical technique of well test imaging and shows examples of application of the technique to a number of reservoirs.

  18. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  19. Standard Test Method for Tension and Vacuum Testing Metallized Ceramic Seals

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers procedures for conducting tension and vacuum tests on metal-ceramic seals to determine the bond strength of brazed, metallized ceramics. This test method is not to be considered as an absolute tension test for the ceramic. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Comparative Analysis of Methods and Tests for Testing Colour Vision of Professional Seafarers

    OpenAIRE

    Rogošić, Veljko; Bojić, Lovro; Kolja Poljak, Nikola; Duplančić, Darko; Vidan, Pero; Ivančić-Kačer, Blanka; Mulić, Rosanda

    2012-01-01

    There are differences among official standards of testing colour vision among different countries, conditioned by out-ofdate, but still enforceable laws and codes. These standards refer to professions in the maritime, air, rail and road traffic. The criteria for testing colour vision are significantly more severe for professionals involved in traffic. For complex diagnostics of colour vision disorder (dyschromatopsia) there are a number of well-known diagnostic methods an...

  1. A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman

    2012-01-01

    The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...

  2. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  3. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  4. Testing Equation Method Modification for Demanding Energy Measurements Verification

    Directory of Open Access Journals (Sweden)

    Elena Kochneva

    2016-01-01

    Full Text Available The paper is devoted to the mathematical approaches of the measurements received from Automatic Meter Reading Systems verification. Reliability of metering data can be improved by application of the new issue named Energy Flow Problem. The paper considers demanding energy measurements verification method based on verification expressions groups analysis. Bad data detection and estimates accuracy calculation is presented using the Automatic Meter Reading system data from the Russian power system fragment.

  5. data_test4 _audit_creation_method SHELXL-97 ...

    Indian Academy of Sciences (India)

    ... direct _atom_sites_solution_secondary difmap _atom_sites_solution_hydrogens geom _refine_ls_hydrogen_treatment constr _refine_ls_extinction_method SHELXL _refine_ls_extinction_coef 0.000559(19) _refine_ls_extinction_expression 'Fc^*^=kFc[1+0.001xFc^2^\\l^3^/sin(2\\q)]^-1/4^' _refine_ls_number_reflns 3365 ...

  6. Small-Item Contact Test Method, FY11 Release

    Science.gov (United States)

    2012-07-01

    and reporting. The basic foundation was augmented by incorporating the elements required by ISO - 17025 and ASTM methods, such as procedure summary...listed in the most current versions of ISO 8655, Parts 1 and 2, and/or ASTM E 1154 for the volume being measured. o Syringe: Positive-displacement...versions of ISO 8655: Parts 1 and 5 and/or ASTM E 1154 for the volume being measured. (Examples: Dispensette and Brinkman are common brands.) • Sample

  7. 40 CFR 61.245 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ...)) (English units) Ci = Concentration of sample component “i” in ppm, as measured by Method 18 of appendix A... specified in § 61.18). Hi = net heat of combustion of sample component “i” at 25 °C and 760 mm Hg (77 °F and... units) = 28.56 ft/sec (English units) K2 = 0.7084 m4/(MJ-sec) (metric units) = 0.087 ft4/(Btu-sec...

  8. Testing the QA Method for Calculating Jet v_{2}

    CERN Document Server

    Mueller, Jason

    2014-01-01

    For the summer, I was assigned to work on the ALICE experiment with Alice Ohlson. I wrote several programs throughout the summer that were used to calculate jet v 2 using a non-standard method described by my supervisor in her Ph.D. thesis. Though the project is not yet complete, significant progress has been made, and the results so far seem promising.

  9. Development and Test of Methods for Fault Detection and Isolation

    DEFF Research Database (Denmark)

    Jørgensen, R.B.

    Almost all industrial systemns are automated to ensure optimal production both in relation to energy consumtion and safety to equipment and humans. All working parts are individually subject to faults. This can lead to unacceptable economic loss or injury to people. This thesis deals with a monit......Almost all industrial systemns are automated to ensure optimal production both in relation to energy consumtion and safety to equipment and humans. All working parts are individually subject to faults. This can lead to unacceptable economic loss or injury to people. This thesis deals...... they are especiallu crucial for the entire operaiton of a closed loop system. The purpose of the thesis is to investigate, deveop, and verify methods for fault detection and isolation on control loop systems. An Industrial Position Controller, (IPC), laboratory setup is used as an application example throughout...... the thesis. The IPC offers prospects of repeated fault scenarios, and support studies in robustness issues. The thesis contributes with a numerical fault analysis representation, practical applications of existing methods for FDI, and a method for robust FDI for practical applications....

  10. Interlaminar shear test method development for long term durability testing of composites

    Science.gov (United States)

    Ifju, Peter G.

    1994-01-01

    The high speed civil transport is a commercial aircraft that is expected to carry 300 passengers at Mach 2.4 over a range of more than 6000 nautical miles. With the existing commercial structural material technology (i.e., aluminum) the performance characteristics of the high speed civil transport would not be realized. Therefore there has been a concerted effort in the development of light weight materials capable of withstanding elevated temperatures for long duration. Thermoplastic composite materials are such candidate materials and the understanding of how these materials perform over the long term under harsh environments is essential to safe and effective design. The matrix dominated properties of thermoplastic composites are most affected by both time and temperature. There is currently an effort to perform short term testing to predict long term behavior of in-plane mechanical properties E22 (transverse modulus of elasticity) and G12 (shear modulus). Out-of-plane properties such as E33, G13, and G23 are inherently more difficult to characterize. This is especially true for the out-of-plane shear modulus G23 and hence there is no existing acceptable standard test method. Since G23 is the most matrix dominated property, it is essential that a test method be developed. A shear test methodology is developed to do just that. The test method, called the double notched specimen, along with the previously developed shear gage was tested at room temperature. Mechanical testing confirmed the attributes of the methodology. A finite element parametric study was conducted for specimen optimization. Moire interferometry, a high sensitivity laser optical method, was used for full-field analysis of the specimen. From this work, material parameters will be determined and thus enable the prediction of long term material behavior of laminates subjected to general loading states.

  11. Validation of laboratory-scale recycling test method of paper PSA label products

    Science.gov (United States)

    Carl Houtman; Karen Scallon; Richard Oldack

    2008-01-01

    Starting with test methods and a specification developed by the U.S. Postal Service (USPS) Environmentally Benign Pressure Sensitive Adhesive Postage Stamp Program, a laboratory-scale test method and a specification were developed and validated for pressure-sensitive adhesive labels, By comparing results from this new test method and pilot-scale tests, which have been...

  12. Applying the Joint Committee's Evaluation Standards for the Assessment of Alternative Testing Methods.

    Science.gov (United States)

    Nevo, David; Shohamy, Elana

    This study is based on three sources: (1) an experimental try-out of four oral proficiency testing methods (oral interview, role play, reporting test, and group discussion); (2) an evaluation of the testing methods by a panel of experts; and (3) an analysis of the same testing methods by policy makers. The findings are reported in terms of the…

  13. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  14. Recommended Minimum Test Requirements and Test Methods for Assessing Durability of Random-Glass-Fiber Composites

    Energy Technology Data Exchange (ETDEWEB)

    Battiste, R.L.; Corum, J.M.; Ren, W.; Ruggles, M.B.

    1999-06-01

    This report provides recommended minimum test requirements are suggested test methods for establishing the durability properties and characteristics of candidate random-glass-fiber polymeric composites for automotive structural applications. The recommendations and suggestions are based on experience and results developed at Oak Ridge National Laboratory (ORNL) under a US Department of Energy Advanced Automotive Materials project entitled ''Durability of Lightweight Composite Structures,'' which is closely coordinated with the Automotive Composites Consortium. The report is intended as an aid to suppliers offering new structural composites for automotive applications and to testing organizations that are called on to characterize the composites.

  15. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. The agar microdilution method - a new method for antimicrobial susceptibility testing for essential oils and plant extracts.

    Science.gov (United States)

    Golus, J; Sawicki, R; Widelski, J; Ginalska, G

    2016-11-01

    To develop a new agar microdilution technique suitable for the assessment of the antimicrobial activity of natural plant products such as essential oils or plant extracts as well as to evaluate the antimicrobial effect of several essential oils and plant extracts. The proposed agar microdilution method was evolved on the basis of the CLSI agar dilution method, approved for conventional antimicrobials. However, this new method combines convenience and time/cost effectiveness typical for microtitre methods with the advantages of the agar dilution of hydrophobic or coloured substances. Different concentrations of the tested agents were added to Eppendorf tubes with molten Mueller-Hinton agar, vortexed and dispensed into the 96-well microplate in a small volume of 100 μl per well which allows for rapid, easy and economical preparation of samples as well as providing a uniform and stable dispersion without separation of the oil-water phases which occurs in methods with liquid medium. Next, the agar microdilution plates were inoculated with four reference bacterial strains. The results of our study demonstrated that the minimal inhibitory concentrations (MICs) were successfully determined using the agar microdilution method even with hydrophobic essential oils or strongly coloured plant extracts. The new agar microdilution method avoids the problems associated with testing of water insoluble, oily or strongly coloured plant natural products. Moreover, it enables the reliable, cheap and easy MIC determination of such agents. In the era of increasing antibiotic resistance high hopes are associated with new drugs of plant origin. However, the lack of standardized and reliable testing methods for assessing antibacterial activity of plant natural products causes impediment to research into this area. This study demonstrated that the agar microdilution method can be used successfully for testing oily and coloured substances. © 2016 The Society for Applied Microbiology.

  17. Alternative methods for radiochemical purity testing in radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Ideli M. de; Martins, Patricia de A.; Silva, Jose L. da; Ramos, Marcelo P.S.; Lima, Jose A.S.; Pujatti, Priscilla B.; Fukumori, Neuza T.O.; Matsuda, Margareth M.N. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The radiochemical purity (RCP) testing is as prerequisite for radiopharmaceuticals before the administration to the patient. Because time is critical in nuclear medicine, emphasis should be given to the radiochemical quality control procedures, in order to obtain the maximum amount of information in the minimum period of time. Radiochemical purity is defined as the proportion of the total radioactivity in the product that is present in the specified chemical form. Usually, the RCP is evaluated by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). The most widely used technique for RCP determination in radiopharmaceutical preparations is TLC-aluminium (TLC-Al), instant thin layer chromatography-silica gel (ITLC-SG) and paper chromatography (PC). Indeed, many of the pharmacopeial methods use these techniques. The purpose of the present study was to evaluate different chromatographic systems for RCP in {sup 67}Ga-Citrate, {sup 111}In-Octreotide, {sup 177}Lu-DOTATATE and {sup 153}Sm-HA. PC was performed with 3MM/1MM Whatman plates, TCL-Al sheets from Merck and ITLC-SG sheets from Pall Corporation and Varian Inc. The mobile phases were 0.16 mol.L{sup -1} sodium acetate, 0.9% sodium chloride (p/v), 0.1 mol.L{sup -1} sodium citrate buffer, 0.2 mol.L{sup -1} EDTA, methanol:0.4 mol.L{sup -1} ammonium acetate (1:1) mixture, and pyridine:ethanol:water (1:2:4) mixture. The samples were placed on plates in triplicate and immediately put into pre-saturated chambers with the mobile phase. After the chromatographic separation, the plates were dried and cut into 7, 10 or 12 segments and each one was separately measured in a gamma counter during 0.20 minutes (set on the radioisotope window). The results in the gamma counter were expressed in counts per minute (cpm). The chromatographic systems for {sup 177}Lu-DOTATATE and {sup 153}Sm-HA gave the best performances in 0.1 mol L{sup -1} sodium citrate buffer/TLC-Al and 0.9% (p/v) sodium chloride

  18. Shear stability test for polymer containing lubrication fluids. Comparison of test methods and test results

    Energy Technology Data Exchange (ETDEWEB)

    Laukotka, E.M. (Deutsche Shell AG, Hamburg (Germany, F.R.). PAE-Labor)

    1990-04-01

    The lifetime of the lubricated parts and the oil change intervals are a measure of the technical progress. The higher the technical standard, the longer is the oil change interval. Long oil change intervals and, especially, lifetime-lubrication leads to the application of 'multigrade lubricants' characterized by a viscosity-index (VI) above 100. As most of these 'multi-grade lubricants' are formulated using high-molecular weight polymers (VI-Improver), which are not totally resistant to shear, their stability in service can change, leading to reduced viscosity index due to mechanical shear of the polymer. Three mechanical methods for determining the mechanical shear stability of polymer containing lubricants will be presented and discussed briefly. (orig.).

  19. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  20. Using Caspar Creek flow records to test peak flow estimation methods applicable to crossing design

    Science.gov (United States)

    Peter H. Cafferata; Leslie M. Reid

    2017-01-01

    Long-term flow records from sub-watersheds in the Caspar Creek Experimental Watersheds were used to test the accuracy of four methods commonly used to estimate peak flows in small forested watersheds: the Rational Method, the updated USGS Magnitude and Frequency Method, flow transference methods, and the NRCS curve number method. Comparison of measured and calculated...

  1. Test method to assess interface adhesion in composite bonding

    NARCIS (Netherlands)

    Teixeira de Freitas, S.; Sinke, J.

    2015-01-01

    This paper introduces a new type of peel tests dedicated to composite bonding: Composite Peel Tests. This test is inspired on the standard floating roller peel test widely used for metal bonding. The aim of this study is to investigate the potential of the Composite Peel Test to assess interface

  2. Test method to assess interface adhesion in composite bonding

    OpenAIRE

    Teixeira de Freitas, S.; Sinke, J

    2015-01-01

    This paper introduces a new type of peel tests dedicated to composite bonding: Composite Peel Tests. This test is inspired on the standard floating roller peel test widely used for metal bonding. The aim of this study is to investigate the potential of the Composite Peel Test to assess interface adhesion in composite bonded structures. To this end, peel tests were performed with nine different types of adhesives and at two environmental temperatures, room temperature and +80°C. The results we...

  3. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Standardized methods for in-place filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, M.; Fretthold, J.K.; Slawski, J.

    1997-08-01

    The conference minutes of a US DOE meeting held on in-place filter testing are presented. The purpose of the conference was to transfer technical in-place testing knowledge throughout the DOE complex. Major items discussed included purchase requisitions, in-place testing, instrumentation, and in-place test personnel qualifications and training. Future actions identified by conference attendees centered on establishing complex-wide DOE policies on training, inspection and testing, and filter specifications.

  5. 29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Test Methods for Protective Clothing E Appendix E to..., App. E Appendix E to Subpart L of part 1910—Test Methods for Protective Clothing This appendix contains test methods which must be used to determine if protective clothing affords the required level of...

  6. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  7. Developing VTM-51 into an ASTM test method.

    Science.gov (United States)

    1993-01-01

    In 1980, the Virginia Transportation Research Council developed a procedure to test silt fence installations (VTM-51). The test determines the filtering efficiency (amount of soil removed) and the flow rate of a geotextile. A known concentration and ...

  8. A new Laplace transformation method for dynamic testing of solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Perers, Bengt; Fan, Jianhua

    2015-01-01

    A new dynamic method for solar collector testing is developed. It is characterized by using the Laplace transformation technique to solve the differential governing equation. The new method was inspired by the so called New Dynamic Method (NDM) (Amer E. et al (1999) [1]) but totally different....... By integration of the Laplace transformation technique with the Quasi Dynamic Test (QDT) model (Fischer S. et al (2004) [2]), the Laplace – QDT (L-QDT) model is derived. Two experimental methods are then introduced. One is the shielding method which needs to shield and un-shield solar collector continuously...... and the natural experimental method. The identified collector parameters are then compared and analyzed with those obtained by the steady state test method and the QDT test method. The results comparison shows that the L-QDT method and the natural experimental method are also valid. It can be concluded...

  9. Particle dispersing system and method for testing semiconductor manufacturing equipment

    Science.gov (United States)

    Chandrachood, Madhavi; Ghanayem, Steve G.; Cantwell, Nancy; Rader, Daniel J.; Geller, Anthony S.

    1998-01-01

    The system and method prepare a gas stream comprising particles at a known concentration using a particle disperser for moving particles from a reservoir of particles into a stream of flowing carrier gas. The electrostatic charges on the particles entrained in the carrier gas are then neutralized or otherwise altered, and the resulting particle-laden gas stream is then diluted to provide an acceptable particle concentration. The diluted gas stream is then split into a calibration stream and the desired output stream. The particles in the calibration stream are detected to provide an indication of the actual size distribution and concentration of particles in the output stream that is supplied to a process chamber being analyzed. Particles flowing out of the process chamber within a vacuum pumping system are detected, and the output particle size distribution and concentration are compared with the particle size distribution and concentration of the calibration stream in order to determine the particle transport characteristics of a process chamber, or to determine the number of particles lodged in the process chamber as a function of manufacturing process parameters such as pressure, flowrate, temperature, process chamber geometry, particle size, particle charge, and gas composition.

  10. Comparing Rotary Bend Wire Fatigue Test Methods at Different Test Speeds

    Science.gov (United States)

    Weaver, Jason D.; Gutierrez, Erick J.

    2015-12-01

    Given its relatively simple setup and ability to produce results quickly, rotary bend fatigue testing is becoming commonplace in the medical device industry and is the subject of a new standard test method ASTM E2948-14. Although some research has been conducted to determine if results differ for different rotary bend fatigue test setups or test speeds, these parameters have not been extensively studied together. In this work, we investigate the effects of these two parameters on the fatigue life of three commonly used medical device alloys (ASTM F2063 nitinol, ASTM F138 stainless steel, and ASTM F1058 cobalt chromium). Results with three different rotary bend fatigue test setups revealed no difference in fatigue life among those setups. Increasing test speed, however, between 100 and 35,000 RPM led to an increased fatigue life for all three alloys studied (average number of cycles to fracture increased between 2.0 and 5.1 times between slowest and fastest test speed). Supplemental uniaxial tension tests of stainless steel wire at varying strain rates showed a strain rate dependence in the mechanical response which could in part explain the increased fatigue life at faster test speeds. How exactly strain rate dependence might affect the fatigue properties of different alloys at different alternating strain values requires further study. Given the difference in loading rates between benchtop fatigue tests and in vivo deformations, the potential for strain rate dependence should be considered when designing durability tests for medical devices and in extrapolating results of those tests to in vivo performance.

  11. Frequency Shift During Mass Properties Testing Using Compound Pendulum Method

    Science.gov (United States)

    Wolfe, David; Regan, Chris

    2012-01-01

    During mass properties testing on the X-48B Blended Wing Body aircraft (The Boeing Company, Chicago, Illinois) at the National Aeronautics and Space Administration Dryden Flight Research Center, Edwards, California, large inertia measurement errors were observed in results from compound pendulum swings when compared to analytical models. By comparing periods of oscillations as measured from an average over the test period versus the period of each oscillation, it was noticed that the frequency of oscillation was shifting significantly throughout the test. This phenomenon was only noticed during compound pendulum swings, and not during bifilar pendulum swings. The frequency shift was only visible upon extensive data analysis of the frequency for each oscillation, and did not appear in averaged frequency data over the test period. Multiple test articles, test techniques, and hardware setups were used in attempts to eliminate or identify the cause of the frequency shift. Plotting the frequency of oscillation revealed a region of minimal shift that corresponded to a larger amplitude range. This region of minimal shift provided the most accurate results compared to a known test article; however, the amplitudes that produce accurate inertia measurements are amplitudes larger than those generally accepted in mass properties testing. This paper examines two case studies of the frequency shift, using mass properties testing performed on a dummy test article, and on the X-48B Blended Wing Body aircraft.

  12. Evaluation of Test/Analysis Correlation Methods for Crash Applications

    Science.gov (United States)

    Lyle, Karen H.; Bark, Lindley W.; Jackson, Karen E.

    2001-01-01

    A project has been initiated to improve crash test and analysis correlation. The work in this paper concentrated on the test and simulation results for a fuselage section. Two drop tests of the section were conducted. The first test was designed to excite the linear structural response for comparison with finite element modal analysis results. The second test was designed to provide data for correlation with crash simulations. An MSC.Dytran model was developed to generate nonlinear transient dynamic results. Following minor modifications, the same model was executed in MSC.Nastran to generate modal analysis results. The results presented in this paper concentrate on evaluation of correlation methodologies for crash test data and finite element simulation results.

  13. Experimental test results from an environmental protection agency test method for determination of vapor suppressant effectiveness

    Science.gov (United States)

    Tock, Richard W.; Ahern, Daniel W.

    2005-04-01

    The results obtained from laboratory experiments conducted using Environmental Protection Agency (EPA) subpart WWWW of 40 Code of Federal Regulations (CFR) part 63 (1)-test method are discussed in this article. The original test method was developed to measure the effectiveness of wax suppressants used to reduce hazardous air pollutant (HAP) emissions from unsaturated polyester (UP)/vinyl ester resins. Wax additions of ˜1.5% by weight to commercial UP resins suppress HAP emissions through the formation of surface barrier films. However, the tests performed in this study included the use of limestone and an adjunct, organic fiber reinforcement, rather than the wax. The addition of either commercial product to the UP formulations tested in this study was also shown to reduce HAP emissions. Suppression was a combination of absorption and an increased diffusion path barrier for the volatile organic carbon (VOC) components. Based on the limited data obtained, it was shown that the oil absorption characteristics of the two adjunct products could be used to estimate the expected level of vapor suppression for a specific resin formulation. Values reported in the literature for the oil adsorption characteristics of the adjunct limestone and the commercial biomass fiber were used in the laboratory tests. Although the oil adsorption characteristic of any ingredient added to a base resin formulation is indicative of its potential for emissions reduction, the EPA test protocol is still required to be performed for validation. Such screening tests will always be needed due to the variability associated with commercial UP resins and the evolution of customized UP/fiberglass composite formulations developed by custom molding shops.

  14. Development of an Impact Resistant Test Method for Polycarbonate.

    Science.gov (United States)

    1984-02-01

    defined test procedures. The notched Izod test has been and continues to be used for qualitatively evaluating impact resitance of polycarbonate per...produced by Dlacing the finish machined samples in a preheated air-circulating Instron heating chamber at 105°C (257°F) for two hours (typical fabrication... heat treatment temperature), followed by air cooldown to room temperature for one hour followed by immediate testing. 12 I H mtmm *m 13 m*m

  15. Simulation and Verificaiton of Flow in Test Methods

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm; Szabo, Peter; Geiker, Mette Rica

    2005-01-01

    Simulations and experimental results of L-box and slump flow test of a self-compacting mortar and a self-compacting concrete are compared. The simulations are based on a single fluid approach and assume an ideal Bingham behavior. It is possible to simulate the experimental results of both tests...... for a given set of rheological parameters. However, it is important to include boundary conditions related to the lifting procedure in the two tests....

  16. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  18. [Ultrasonic diagnosis of undescended testes. Methods and possibilities].

    Science.gov (United States)

    Johansen, T E; Larmo, A

    1989-02-20

    83 boys with 123 empty hemiscroti were assessed by clinical examination and ultrasound. After repeated clinical examination with the patient in general anesthesia 60 undescended testes were operated. We present the technical aspects of examination of undescended testes by ultrasound. When testicular position as established by ultrasound was compared with intraoperative finding position, ultrasound had a very high sensitivity, specificity and accuracy for testes positioned distal to the internal ring. The anatomical position of the testis at sonography and the patient's age provide objective evidence to discern retractile and truly undescended testes.

  19. What Happened to Remote Usability Testing? An Empirical Study of Three Methods

    DEFF Research Database (Denmark)

    Stage, Jan; Andreasen, M. S.; Nielsen, H. V.

    2007-01-01

    The idea of conducting usability tests remotely emerged ten years ago. Since then, it has been studied empirically, and some software organizations employ remote methods. Yet there are still few comparisons involving more than one remote method. This paper presents results from a systematic...... empirical comparison of three methods for remote usability testing and a conventional laboratorybased think-aloud method. The three remote methods are a remote synchronous condition, where testing is conducted in real time but the test monitor is separated spatially from the test subjects, and two remote...

  20. Standard test method for nondestructive assay of special nuclear material holdup using Gamma-Ray spectroscopic methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes gamma-ray methods used to nondestructively measure the quantity of 235U, or 239Pu remaining as holdup in nuclear facilities. Holdup occurs in all facilities where nuclear material is processed, in process equipment, in exhaust ventilation systems and in building walls and floors. 1.2 This test method includes information useful for management, planning, selection of equipment, consideration of interferences, measurement program definition, and the utilization of resources (1, 2, 3, 4). 1.3 The measurement of nuclear material hold up in process equipment requires a scientific knowledge of radiation sources and detectors, transmission of radiation, calibration, facility operations and error analysis. It is subject to the constraints of the facility, management, budget, and schedule; plus health and safety requirements; as well as the laws of physics. The measurement process includes defining measurement uncertainties and is sensitive to the form and distribution of the material...

  1. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    Science.gov (United States)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    As fracture mechanics material testing evolves, the governing test standards continue to be refined to better reflect the latest understanding of the physics of the fracture processes involved. The traditional format of ASTM fracture testing standards, utilizing equations expressed directly in the text of the standard to assess the experimental result, is self-limiting in the complexity that can be reasonably captured. The use of automated analysis techniques to draw upon a rich, detailed solution database for assessing fracture mechanics tests provides a foundation for a new approach to testing standards that enables routine users to obtain highly reliable assessments of tests involving complex, non-linear fracture behavior. Herein, the case for automating the analysis of tests of surface cracks in tension in the elastic-plastic regime is utilized as an example of how such a database can be generated and implemented for use in the ASTM standards framework. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  2. European wind turbine procedure development blade test methods and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Bulder, B.H.; Dam, J.J.D. van; Delft, D.R.V. van [and others

    1999-03-01

    In this paper the preliminary results obtained by performing the second task of the `European Wind Turbine Testing Procedure Development` project are presented. This project is performed within and with financial support of the Standards, Measurements and Testing programme of the European Commission. (au)

  3. Methods for testing of geometrical down-scaled rotor blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    as requirements for experimental facilities are very demanding and furthermore the time for performing the experimental test campaign and the cost are not well suitable for most research projects. This report deals with the advantages, disadvantages and open questions of using down-scaled testing on wind turbine...

  4. Statistical tests for equal predictive ability across multiple forecasting methods

    DEFF Research Database (Denmark)

    Borup, Daniel; Thyrsgaard, Martin

    We develop a multivariate generalization of the Giacomini-White tests for equal conditional predictive ability. The tests are applicable to a mixture of nested and non-nested models, incorporate estimation uncertainty explicitly, and allow for misspecification of the forecasting model as well...

  5. A testing apparatus and a method of operating the same

    DEFF Research Database (Denmark)

    2014-01-01

    A testing apparatus for sequentially performing deformation tests on a plurality of samples, and having a support structure (11) and a sample magazine 6 with multiple mutually spaced apart sample holders (18), each being adapted for supporting one sample spaced apart from the samples supported by...

  6. Transform methods for testing the negative binomial hypothesis

    Directory of Open Access Journals (Sweden)

    Simos G. Meintanis

    2007-10-01

    Full Text Available We employ the empirical probability generating function in constructing a goodness-of-fit test for negative binomial distributions. The proposed tests, which are formed as weighted integrals, are shown to be consistent and their asymptotic null distribution is investigated. As the decay of the weight function tends to infinity, limit statistics are obtained. A small simulation study is presented.

  7. Improving the Traditional Testing Methods in Learning Foreign Languages

    DEFF Research Database (Denmark)

    Pachovski, Veno; Dimova, Slobodanka; Vaneva, Marjana

    2012-01-01

    A model for gathering oral answers as part of testing the speaker skills (i.e. command of language, native or foreign) is presented, as well as the software used in the experimentation. The research presented here is a result of more than six (6) months’ work with TESOL experts, based on 60 test...

  8. 40 CFR 60.335 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... (Ho−0.00633) (288°K/Ta)1.53 Where: NOX = emission concentration of NOX at 15 percent O2 and ISO... kilopascals ambient pressure, mm Hg, Po = observed combustor inlet absolute pressure at test, mm Hg, Ho... under § 60.334(b). (iii) The requirement to test at three additional load levels is waived. (8) If the...

  9. Standard Test Method for Hydrophobic Surface Films by the Water-Break Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard test method for conducting wet sand/rubber wheel abrasion tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers laboratory procedures for determining the resistance of metallic materials to scratching abrasion by means of the wet sand/rubber wheel test. It is the intent of this procedure to provide data that will reproducibly rank materials in their resistance to scratching abrasion under a specified set of conditions. 1.2 Abrasion test results are reported as volume loss in cubic millimeters. Materials of higher abrasion resistance will have a lower volume loss. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Standard Test Method for Hydrophobic Surface Films by the Atomizer Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1965-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of fractional molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces the sensitivity of the test may be significantly decreased. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Methods for conducting an introductory flight test engineering course

    Science.gov (United States)

    Shelton, Gentry

    This thesis serves as a guide to teaching an introductory flight test engineering course. There are several references pertaining to this area of study, but they are limited in their discussion of the details in how the professor can teach the course, how the professor can handle the logistics of the course, how the students can record and reduce the data and how the pilot can perform the flight test maneuvers. As such, this thesis, along with the materials developed therein, serves the reader as a guide to developing and conducting an introductory flight test engineering course. Materials were developed for the parties involved with an introductory flight test engineering course. Lesson plans and background theory is developed for the professor of the course. In-flight videos and flight maneuver manuals were developed to assist the pilot with flying the maneuvers. In-flight videos, a workbook and in-flight data collection manuals were developed to teach the students the basics of flight test engineering. A chapter is also dedicated to the logistics of the course for the professor. With these materials, any university interested in teaching the basics of flight test engineering will have a foundation to build upon. They will also be guided in the selection of a pilot who can perform the flight test maneuvers required of this course.

  13. The mixed-mode bending method for delamination testing

    Science.gov (United States)

    Reeder, James R.; Crews, John H., Jr.

    1989-01-01

    A mixed-mode bending (MMB) test procedure is presented which combines double cantilever beam mode-I loading and end-notch flexure mode II loading on a split, unidirectional laminate. The MMB test has been analyzed by FEM and by beam theory in order to ascertain the mode I and mode II components' respective strain energy release rates, G(I) and G(II); these analyses indicate that a wide range of G(I)/G(II) ratios can be generated by varying the applied load's position on the loading lever. The MMB specimen analysis and test procedures are demonstrated for the case of AS4/PEEK unidirectional laminates.

  14. Development of a new test method for Mineral Based Composites

    DEFF Research Database (Denmark)

    Täljsten, Björn; Orosz, Katalin

    2008-01-01

    The well-known wedge splitting test, often used for characterizing brittle materials has been modified and adapted to testing MBC-reinforced concrete under splitting load. MBC (Mineral Based Composites) is a newly developed strengthening system for existing concrete structures where FRPs, mainly...... CFRP grids are externally bonded to the concrete surface by means of cementitious bonding agents. Crack development, crack patterns, crack opening displacement (COD) versus splitting load and fracture energy are investigated and evaluated. Development of a suitable test specimen and test setup has been...... accomplished. Bond provided by both mortars was excellent leading to CFRP rupture. By applying PVA-reinforced ductile ECC as bonding agent, improved performance, significantly higher fracture energy, multiple cracking and enhanced ductility were observed, caused by improved bond between grid and mortar due...

  15. Evaluation of Fire Test Methods for Aircraft Thermal Acoustical Insulation

    Science.gov (United States)

    1997-09-01

    This report presents the results of laboratory round robin flammability testing performed on thermal acoustical insulation blankets and the films used as insulation coverings. This work was requested by the aircraft industry as a result of actual inc...

  16. New methods for the safety testing of transgenic food

    DEFF Research Database (Denmark)

    Knudsen, Ib; Poulsen, Morten; Kledal, S. T.

    2004-01-01

    on the OECD 90 day rodent study supplemented with sensitive and specific markers for potential toxicity of the products encode by the inserted genes in the tested food item, the use of a semisynthetic diet with interchangeable constituents and the extensive use of initial chemical and in-vitro testing...... for guiding the precise design of the animal study. The genetically modified food plants to be used for this test development will be 3 transgenic rice varieties (2 types of lectins and the Bt toxin). Objectives The overall objective of this project is to develop and validate the scientific methodology which...... in a scientifically valid and economically feasible manner. The specific objectives are to: improve the sensitivity and specificity of standard OECD guideline toxicity tests towards detection of specific chemical entities in the GM food matrix by the measurement of additional biological endpoints based on prior...

  17. Correlation of geotextile puncture test methods : research brief.

    Science.gov (United States)

    2017-05-01

    Geotextiles are commonly used in pavements, earth retaining structures, landfills and other geotechnical contexts. Various tests are conducted to evaluate and classify geotextiles to determine their suitability for each of these applications. The AST...

  18. Isentropic Bulk Modulus: Development of a Federal Test Method

    Science.gov (United States)

    2016-01-01

    bulk modulus space from synthetic iso -paraffinic fuels to petroleum-based diesel fuels. The test fuels are identified in Table 1. A testing order and...13000 100 14000 100 15000 100 UNCLASSIFIED UNCLASSIFIED 7 3.3 ROUND ROBIN PROCEDURE The following notes were provided to the participating...2 Table A-1. Sample 6065 at 35 °C Density psi 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 Avg g/cm3

  19. Mixed-Mode Bending Method for Delamination Testing

    Science.gov (United States)

    Reeder, James R.; Crews, John R., Jr.

    1990-01-01

    A mixed mode delamination test procedure was developed combining double cantilever beam (DCB) mode I loading and end-notch fixture (ENF) mode II loading on a split unidirectional laminate. By loading with a lever, a single applied load simultaneously produces mode I and mode II bending loads on the specimen. This mixed-mode bending (MMB) test was analyzed using both finite-element procedures and beam theory to calculate the mode I and mode II components of strain-energy release rate G(sub I) and G(sub II), respectively. A wide range of G(sub I)/G(sub II) ratios can be produced by varying the load position on the lever. As the delamination extended, the G(sub I)/G(sub II) ratios varied by less than 5%. Beam theory equations agreed closely with the finite-element results and provide a basis for selection of G(sub I)/G(sub II) test ratios and a basis for computing the mode I and mode II components of measured delamination toughness. The MMB test was demonstrated using AS4/PEEK (APC2) unidirectional laminates. The MMB test introduced in this paper is rather simple and is believed to offer several advantages over most current mixed-mode test.

  20. Estimating the Relationship between Use of Test-Preparation Methods and Scores on the Graduate Management Admission Test.

    Science.gov (United States)

    Leary, Linda F.; Wightman, Lawrence E.

    This study sought to examine the relationship between five methods of test preparation and test performance as measured by Graduate Management Admission Test (GMAT) Verbal, Quantitative and Total scores. Data on method of test preparation were obtained through voluntary examinee response to five questions which appeared on the answer sheets. One…

  1. Multiple HEPA filter test methods, January--December 1976

    Energy Technology Data Exchange (ETDEWEB)

    Schuster, B.; Kyle, T.; Osetek, D.

    1977-06-01

    The testing of tandem high-efficiency particulate air (HEPA) filter systems is of prime importance for the measurement of accurate overall system protection factors. A procedure, based on the use of an intra-cavity laser particle spectrometer, has been developed for measuring protection factors in the 10/sup 8/ range. A laboratory scale model of a filter system was constructed and initially tested to determine individual HEPA filter characteristics with regard to size and state (liquid or solid) of several test aerosols. Based on these laboratory measurements, in-situ testing has been successfully conducted on a number of single and tandem filter installations within the Los Alamos Scientific Laboratory as well as on extraordinary large single systems at Rocky Flats. For the purpose of recovery and for simplified solid waste disposal, or prefiltering purposes, two versions of an inhomogeneous electric field air cleaner have been devised and are undergoing testing. Initial experience with one of the systems, which relies on an electrostatic spraying phenomenon, indicates performance efficiency of greater than 99.9% for flow velocities commonly used in air cleaning systems. Among the effluents associated with nuclear fuel reprocessing is /sup 129/I. An intra-cavity laser detection system is under development which shows promise of being able to detect mixing ratios of one part in 10/sup 7/, I/sub 2/ in air.

  2. Interlaboratory drug susceptibility testing of Mycobacterium tuberculosis by a radiometric procedure and two conventional methods

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqi, S.H.; Hawkins, J.E.; Laszlo, A.

    1985-12-01

    A total of 224 recent isolates of Mycobacterium tuberculosis from 163 patients selected to have multidrug resistance were tested against streptomycin (SM), isoniazid, rifampin, and ethambutol (EMB) by the rapid radiometric BACTEC method and two conventional proportion methods: the World Health Organization (WHO) method, using Lowenstein-Jensen medium; and the Veterans Administration reference laboratory for mycobacteria (VA) method, using Middlebrook 7H10 agar medium. The results were compared, focusing on the concentrations of the drugs in all three methods. Among the four drugs tested, most of the discrepancies in measured activity were observed with SM and EMB, generally because of differences in the drug concentrations used by the three methods. A 4-micrograms amount of SM in the BACTEC method was found to be slightly less active than 10 micrograms in the VA method and significantly more active than 4 micrograms of dihydrostreptomycin in the WHO method. With EMB, 2.5 micrograms in BACTEC was similar to 5 micrograms in the VA method and 2 micrograms in the WHO method, while 10 micrograms in the BACTEC method was found to be more active than 10 and 2 micrograms in the VA and WHO methods, respectively. To attain close agreement, drug concentrations used in the BACTEC method should be carefully selected when a comparison is to be made with any conventional method employed in a laboratory. Standardization of in vitro susceptibility testing is greatly needed to achieve uniformity among the test methods used to evaluate tuberculosis therapeutics.

  3. Standard test methods for analysis of sintered gadolinium oxide-uranium dioxide pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 These test methods cover procedures for the analysis of sintered gadolinium oxide-uranium dioxide pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Section Carbon (Total) by Direct CombustionThermal Conductivity Method C1408 Test Method for Carbon (Total) in Uranium Oxide Powders and Pellets By Direct Combustion-Infrared Detection Method Chlorine and Fluorine by Pyrohydrolysis Ion-Selective Electrode Method C1502 Test Method for Determination of Total Chlorine and Fluorine in Uranium Dioxide and Gadolinium Oxide Gadolinia Content by Energy-Dispersive X-Ray Spectrometry C1456 Test Method for Determination of Uranium or Gadolinium, or Both, in Gadolinium Oxide-Uranium Oxide Pellets or by X-Ray Fluorescence (XRF) Hydrogen by Inert Gas Fusion C1457 Test Method for Determination of Total Hydrogen Content of Uranium Oxide Powders and Pellets by Carrier Gas Extraction Isotopic Uranium Composition by Multiple-Filament Surface-Ioni...

  4. Method and device for tensile testing of cable bundles

    Science.gov (United States)

    Robertson, Lawrence M; Ardelean, Emil V; Goodding, James C; Babuska, Vit

    2012-10-16

    A standard tensile test device is improved to accurately measure the mechanical properties of stranded cables, ropes, and other composite structures wherein a witness is attached to the top and bottom mounting blocks holding the cable under test. The witness is comprised of two parts: a top and a bottom rod of similar diameter with the bottom rod having a smaller diameter stem on its upper end and the top rod having a hollow opening in its lower end into which the stem fits forming a witness joint. A small gap is present between the top rod and the larger diameter portion of the bottom rod. A standard extensometer is attached to the top and bottom rods of the witness spanning this small witness gap. When a force is applied to separate the mounting blocks, the gap in the witness expands the same length that the entire test specimen is stretched.

  5. Development of a Contact Permeation Test Fixture and Method

    Science.gov (United States)

    2013-04-01

    Permeation and Analytical Solutions Team Quality System documentation and the guidance found in the ISO 17025 standard. All permeation and...annular ring (left) and no pressure (right). 2.2.4 Quality Controls Analytical permeation testing was conducted in accordance with ISO 17025 quality

  6. 40 CFR 63.180 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... emission test using the techniques specified in § 63.11(b)(4). (2) Determine the net heating value of the..., psig/hr. Pf=Final pressure, psig. Pi=Initial pressure, psig. tf−ti=Elapsed time, hours. (4) The...

  7. 40 CFR 63.1257 - Test methods and compliance procedures.

    Science.gov (United States)

    2010-07-01

    .... (C) The span value of the analyzer must be less than 100 ppmv. (7) Testing conditions for continuous... below the values defining Group 1 storage vessels specified in table 5 or table 6 of this subpart” is... = ideal gas law constant T = temperature of the vessel vapor space; absolute Pi = partial pressure of the...

  8. Semi-Empirical Method Interpretation of Cone Penetration Test (CPT ...

    African Journals Online (AJOL)

    Cone Penetration Test (CPT) is a reliable technique for measuring subsurface soil friction, cohesion and bearing capacity for pile foundation. In some parts of the ... The approach is suitable because of the insensitivity of the mechanical cone penetrometer in measuring skin friction, especially in clay deposits. Discovery and ...

  9. NAWCAD photogrammetrics: methods and applications for aviation test and evaluation

    Science.gov (United States)

    Stancil, Robert F.; Forsman, Alec E.; Williams, James W.

    1997-12-01

    Photogrammetry using multiple sequential recorded film and video images has been an integral part of flight test and evaluation at the Naval Air Warfare Center Aircraft Division (NAWCAD) at Patuxent River, Maryland for nearly 40 years. Photogrammetric analysis is used for evaluation of stores separation, carrier suitability, ballistic trajectory tracking, overhead impact scoring, and mishap reconstruction. NAWCAD, Patuxent River, Maryland recently began flight testing for the F/A-18 E/F development program. The initial phase of the weapons separation portion of the F/A-18 E/F development program is a 13 month project consisting of two aircraft flying 256 flights during which 2000 stores will be dropped. To meet the challenge of processing high volumes of photogrammetric data and delivering solutions within 72 hours of each flight, the NAWCAD Photogrammetric Team initiated strategies to reduce the time and to increase the volume of data analysis, and to increase the accuracies of solution processes that historically have been labor intensive and difficult to present. The NAWCAD Photogrammetric Team is developing an image enhancement and data analysis system, and the on-line database which will provide near real-time access and retrievability of test data. This paper describes how NAWCAD scientists have applied a clearly defined process for photogrammetric efforts, and implemented state-of-the-art hardware and software methodologies and architecture that reduce the turnaround time, reduce the cost, increase the accuracy, and facilitate the delivery of custom-formatted products to the flight test engineer.

  10. Continuous-Flow Biochips: Technology, Physical Design Methods and Testing

    DEFF Research Database (Denmark)

    Pop, Paul; Araci, Ismail Emre; Chakrabarty, Krishnendu

    2015-01-01

    This article is a tutorial on continuous-flow biochips where the basic building blocks are microchannels, and microvalves, and by combining them, more complex units such as mixers, switches, and multiplexers can be built. It also presents the state of the art in flow-based biochip technology and ...... and emerging research challenges in the areas of physical design and testing techniques....

  11. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    Science.gov (United States)

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an

  12. Evaluation of methods to test chemicals suitability for umbilical applications

    Energy Technology Data Exchange (ETDEWEB)

    Allenson, S. J.; Lindeman, O. E.; Cenegy, L. M.

    2006-03-15

    Offshore deep-water projects are increasingly deploying chemicals to sub-sea wellheads through umbilical lines. There is no margin for error in umbilical chemical treatment programs since any flow blockage in a sub-sea line would result in a multi-million dollar problem. Chemicals for umbilical delivery must also meet strict requirements in their performance and especially their handling properties. Umbilical delivery must be effective at low concentrations in preventing corrosion, scale, hydrates, asphaltenes, paraffin and a host of other problems. Chemical transiting an umbilical can experience pressures as high as 15,000 psi and temperatures ranging from near 0 deg C to greater than 120 deg C. Since some umbilicals are as long as 80 km, a week or more can elapse from the time the chemical is injected at the platform until it reaches the sub-sea well. Therefore, the chemical must not only be stable under all temperature and pressure conditions that it may experience in the umbilical line, it must also be stable under these conditions for a long period of time. Since many umbilical lines actually terminate into sub-sea valves and connectors that are only a few hundred microns in diameter, it is critical that the injected chemical have a low viscosity at sub-sea temperatures and pressures and that it be completely free of particles. These issues present substantial challenges in formulating and manufacturing chemicals for umbilical applications that must be addressed prior to approval of a product for use. Each of these challenges was taken into consideration and a series of tests were developed to assure reliable chemical pump ability through an umbilical line. The tests developed included enhanced formulation stability tests under umbilical temperature and pressure conditions, NAS Class rating, extensive material compatibility testing to include all metals and elastomers that may be used in umbilical injection systems and comprehensive physical property testing

  13. A multiple testing method for hypotheses structured in a directed acyclic graph

    NARCIS (Netherlands)

    Meijer, R.J.; Goeman, J.J.

    2015-01-01

    We present a novel multiple testing method for testing null hypotheses that are structured in a directed acyclic graph (DAG). The method is a top-down method that strongly controls the familywise error rate and can be seen as a generalization of Meinshausen's procedure for tree-structured

  14. Testing of Method for Assessing of Room Thermal Stability

    Directory of Open Access Journals (Sweden)

    Charvátová Hana

    2017-01-01

    Full Text Available The paper presents the interim results of our research on the developing methodological procedure which could be used for assessment of a thermal stability of buildings with regards to its thermal accumulative parameters. The principle of testing is based on a combination of computer simulation of cooled room model developed in COMSOL Multiphysics software and on theoretical calculations with respect to compliance with valid European and Czech technical standards used in building industry and architecture under conditions obtained by real measurement for the room to be tested. The presented example shows the effect of the heataccumulation properties of the outside wall insulation materials on the course of the cooling room for winter conditions.

  15. A Survey of Biodynamic Test Devices and Methods,

    Science.gov (United States)

    1984-04-01

    Frequency RanCe 27000iz e.4, Number 1 e.4.a, on sled 21/2q e.4.b. on subject/dumrly f. Other Parameters Monitoreo : LUNG PRESSURE. BELT FORCES I IJ I...4.a. on ile_ _ _ v.4.u. un s.uject/ourvy I. Other Parameters Monitoreo : 40 NATO/AGARD Impact Test Facility Survey ID #33 1. Name and Address of

  16. Development of a Chronic Toxicity Testing Method for Daphnia pulex

    Science.gov (United States)

    2015-08-01

    Protection Agency YCT yeast , cereal leaves, and trout chow (from a commercial vendor) ERDC/EL SR-15-5 1 1 Introduction The chronic...cm with Milli-Q water) • YCT ( yeast , cereal leaves, trout chow) • ALG- algae, Selenastrum capricornutum(from a commercial vendor); also known as...screened holes (10 replicate beakers for each test concentration) • One modified Zumwalt box (Figures A1-A3) with water exchange system (optional) • One

  17. Small-Item Vapor Test Method, FY11 Release

    Science.gov (United States)

    2012-07-01

    common test agents using field manual values. Agent HD&L VX Toxic-Load Exponent n = 1 n = 1 Effects Mild (eye irritation) Mild ( miosis , rhinorrhea...Exponent n = 1.4 n = 1.5 Effects Mild ( miosis , rhinorrhea) Mild ( miosis , rhinorrhea) Units mg^min/m" mg1&min/m4t> Level ETL50 ETL16 ETL01 ETL50

  18. GMI Instrument Spin Balance Method, Optimization, Calibration, and Test

    Science.gov (United States)

    Ayari, Laoucet; Kubitschek, Michael; Ashton, Gunnar; Johnston, Steve; Debevec, Dave; Newell, David; Pellicciotti, Joseph

    2014-01-01

    The Global Microwave Imager (GMI) instrument must spin at a constant rate of 32 rpm continuously for the 3 year mission life. Therefore, GMI must be very precisely balanced about the spin axis and CG to maintain stable scan pointing and to minimize disturbances imparted to the spacecraft and attitude control on-orbit. The GMI instrument is part of the core Global Precipitation Measurement (GPM) spacecraft and is used to make calibrated radiometric measurements at multiple microwave frequencies and polarizations. The GPM mission is an international effort managed by the National Aeronautics and Space Administration (NASA) to improve climate, weather, and hydro-meteorological predictions through more accurate and frequent precipitation measurements. Ball Aerospace and Technologies Corporation (BATC) was selected by NASA Goddard Space Flight Center to design, build, and test the GMI instrument. The GMI design has to meet a challenging set of spin balance requirements and had to be brought into simultaneous static and dynamic spin balance after the entire instrument was already assembled and before environmental tests began. The focus of this contribution is on the analytical and test activities undertaken to meet the challenging spin balance requirements of the GMI instrument. The novel process of measuring the residual static and dynamic imbalances with a very high level of accuracy and precision is presented together with the prediction of the optimal balance masses and their locations.

  19. A Novel Method for Repeatable Failure Testing of Annulus Fibrosus.

    Science.gov (United States)

    Werbner, Benjamin; Zhou, Minhao; O'Connell, Grace

    2017-11-01

    Tears in the annulus fibrosus (AF) of the intervertebral disk can result in disk herniation and progressive degeneration. Understanding AF failure mechanics is important as research moves toward developing biological repair strategies for herniated disks. Unfortunately, failure mechanics of fiber-reinforced tissues, particularly tissues with fibers oriented off-axis from the applied load, is not well understood, partly due to the high variability in reported mechanical properties and a lack of standard techniques ensuring repeatable failure behavior. Therefore, the objective of this study was to investigate the effectiveness of midlength (ML) notch geometries in producing repeatable and consistent tissue failure within the gauge region of AF mechanical test specimens. Finite element models (FEMs) representing several notch geometries were created to predict the location of bulk tissue failure using a local strain-based criterion. FEM results were validated by experimentally testing a subset of the modeled specimen geometries. Mechanical testing data agreed with model predictions (∼90% agreement), validating the model's predictive power. Two of the modified dog-bone geometries ("half" and "quarter") effectively ensured tissue failure at the ML for specimens oriented along the circumferential-radial and circumferential-axial directions. The variance of measured mechanical properties was significantly lower for notched samples that failed at the ML, suggesting that ML notch geometries result in more consistent and reliable data. In addition, the approach developed in this study provides a framework for evaluating failure properties of other fiber-reinforced tissues, such as tendons and meniscus.

  20. Comparison of Statistical Methods for Detector Testing Programs

    Energy Technology Data Exchange (ETDEWEB)

    Rennie, John Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Abhold, Mark [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-14

    A typical goal for any detector testing program is to ascertain not only the performance of the detector systems under test, but also the confidence that systems accepted using that testing program’s acceptance criteria will exceed a minimum acceptable performance (which is usually expressed as the minimum acceptable success probability, p). A similar problem often arises in statistics, where we would like to ascertain the fraction, p, of a population of items that possess a property that may take one of two possible values. Typically, the problem is approached by drawing a fixed sample of size n, with the number of items out of n that possess the desired property, x, being termed successes. The sample mean gives an estimate of the population mean p ≈ x/n, although usually it is desirable to accompany such an estimate with a statement concerning the range within which p may fall and the confidence associated with that range. Procedures for establishing such ranges and confidence limits are described in detail by Clopper, Brown, and Agresti for two-sided symmetric confidence intervals.

  1. Standard test method for wear testing with a pin-on-disk apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers a laboratory procedure for determining the wear of materials during sliding using a pin-on-disk apparatus. Materials are tested in pairs under nominally non-abrasive conditions. The principal areas of experimental attention in using this type of apparatus to measure wear are described. The coefficient of friction may also be determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Implementation of a Biaxial Resonant Fatigue Test Method on a Large Wind Turbine Blade

    Energy Technology Data Exchange (ETDEWEB)

    Snowberg, D.; Dana, S.; Hughes, S.; Berling, P.

    2014-09-01

    A biaxial resonant test method was utilized to simultaneously fatigue test a wind turbine blade in the flap and edge (lead-lag) direction. Biaxial resonant blade fatigue testing is an accelerated life test method utilizing oscillating masses on the blade; each mass is independently oscillated at the respective flap and edge blade resonant frequency. The flap and edge resonant frequency were not controlled, nor were they constant for this demonstrated test method. This biaxial resonant test method presented surmountable challenges in test setup simulation, control and data processing. Biaxial resonant testing has the potential to complete test projects faster than single-axis testing. The load modulation during a biaxial resonant test may necessitate periodic load application above targets or higher applied test cycles.

  3. Optical Methods For Automatic Rating Of Engine Test Components

    Science.gov (United States)

    Pritchard, James R.; Moss, Brian C.

    1989-03-01

    In recent years, increasing commercial and legislative pressure on automotive engine manufacturers, including increased oil drain intervals, cleaner exhaust emissions and high specific power outputs, have led to increasing demands on lubricating oil performance. Lubricant performance is defined by bench engine tests run under closely controlled conditions. After test, engines are dismantled and the parts rated for wear and accumulation of deposit. This rating must be consistently carried out in laboratories throughout the world in order to ensure lubricant quality meeting the specified standards. To this end, rating technicians evaluate components, following closely defined procedures. This process is time consuming, inaccurate and subject to drift, requiring regular recalibration of raters by means of international rating workshops. This paper describes two instruments for automatic rating of engine parts. The first uses a laser to determine the degree of polishing of the engine cylinder bore, caused by the reciprocating action of piston. This instrument has been developed to prototype stage by the NDT Centre at Harwell under contract to Exxon Chemical, and is planned for production within the next twelve months. The second instrument uses red and green filtered light to determine the type, quality and position of deposit formed on the piston surfaces. The latter device has undergone feasibility study, but no prototype exists.

  4. The SACD method and the XLRS squamometry tests revisited.

    Science.gov (United States)

    Piérard-Franchimont, C; Henry, F; Piérard, G E

    2000-12-01

    The assessment of many aspects of the structure and biological dynamics of the stratum corneum can be conducted using calibrated stripping with adhesive-coated discs (SACD). Squamometry entails staining SACD samples with a toluidine blue-basic fuschsin ethanol-based solution and reading the colorimetric variable Chroma C* representing the squamometry index. Four main variants of squamometry index have been designed so far. Squamometry X refers to the assessment of xerosis and any scaly condition. Squamometry L explores the intercorneocyte cohesiveness impaired by ultraviolet light. Squamometry R evaluates stratum corneum renewal and squamometry S assesses the effect of surfactants on corneocyte integrity. This latter variant is related to, although not similar to, the ex-vivo corneosurfametry bioassay. All squamometry tests are rapid, reliable, sensitive and cheap.

  5. Test method research on weakening interface strength of steel - concrete under cyclic loading

    Science.gov (United States)

    Liu, Ming-wei; Zhang, Fang-hua; Su, Guang-quan

    2018-02-01

    The mechanical properties of steel - concrete interface under cyclic loading are the key factors affecting the rule of horizontal load transfer, the calculation of bearing capacity and cumulative horizontal deformation. Cyclic shear test is an effective method to study the strength reduction of steel - concrete interface. A test system composed of large repeated direct shear test instrument, hydraulic servo system, data acquisition system, test control software system and so on is independently designed, and a set of test method, including the specimen preparation, the instrument preparation, the loading method and so on, is put forward. By listing a set of test results, the validity of the test method is verified. The test system and the test method based on it provide a reference for the experimental study on mechanical properties of steel - concrete interface.

  6. Finite Element Analysis of Nondestructive Testing by Leakage Flux Method Using Remanent Magnetism

    OpenAIRE

    坪井, 始; 瀬島, 紀夫; 田中, 始男; ツボイ, ハジメ; セシマ, ノリオ; タナカ, モトオ; Hajime, TSUBOI; Norio, SESHIMA; Motoo, TANAKA

    2003-01-01

    Magnetic field analysis of nondestructive testing using remanent magnetism was performed by using two-dimensional finite element method. A leakage flux method using remanent magnetism is applied to magnetic material as nondestructive testing method. The remanent magnetism is approximated by equivalent magnetizing electric current. And we assumed that the remanent magnetization is in proportion to the magnetization in the magnetizing process. Formulation of the finite element method using magn...

  7. Validation of the ANSR Salmonella method for detection of Salmonella spp. in a variety of foods. Performance Tested Method 061203.

    Science.gov (United States)

    Caballero, Oscar; Alles, Susan; Gray, R Lucas; Tolan, Jerry; Mozola, Mark; Rice, Jennifer

    2014-01-01

    This study represents a proposal to extend the matrix claims for the ANSR Salmonella test, Performance Tested Method 061203. The test is based on the nicking enzyme amplification reaction (NEAR) isothermal nucleic acid amplification technology. The assay platform features simple instrumentation, minimal labor, and following a single-step 16-24 h enrichment (depending on sample type), an extremely short assay time of 30 min including sample preparation. Detection is real-time using fluorescent molecular beacon probes. ANSR Salmonella was originally validated for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, and oat cereal, and on stainless steel, plastic, sealed concrete, ceramic tile, and rubber surfaces. The matrixes tested in this study include pet food, ice cream, soy flour, raw almonds, peanut butter, spinach, black pepper, raw frozen shrimp, cocoa powder, and pasteurized dried egg. In unpaired comparative testing there were no statistically significant differences in the number of positive results obtained with the ANSR and the reference culture methods. Enrichment for 16 h was effective for all commodities tested except ice cream, black pepper, dried pasteurized egg, and 375 g samples of dry pet food, for which enrichment for 24 h is indicated.

  8. Testing the local spacetime dynamics by heliospheric radiocommunication methods

    Directory of Open Access Journals (Sweden)

    H.-J. Fahr

    2008-05-01

    Full Text Available According to general relativistic theories, cosmological spacetime is dynamic. This prediction is in excellent agreement with the huge majority of astronomical observations on large cosmic scales, especially the observations of cosmological redshifts of distant galaxies. However, on scales of heliospheric distances, verifications of general relativistic effects are based on Schwarzschild metric tests or kinetical corrections, such as the perihelion motion of Mercury, photon deflection at the Sun and gravitational photon redshifts in central gravity fields. As we will show in this paper, there is, however, a chance to detect new cosmologically relevant features on heliospheric scales by careful study of photon propagations in the local spacetime metrics, based on red- or blueshifts as a clear, but up to now overlooked, signature of the local spacetime dynamics. Thus, we propose the challenging possibility of carrying out experiments of cosmological relevance by simply using high-precision radio tracking of heliospheric spaceprobes, as already practised in cases like Pioneer-10/11, Galileo and Ulysses.

  9. Using Response Surface Methods to Correlate the Modal Test of an Inflatable Test Article

    Science.gov (United States)

    Gupta, Anju

    2013-01-01

    This paper presents a practical application of response surface methods (RSM) to correlate a finite element model of a structural modal test. The test article is a quasi-cylindrical inflatable structure which primarily consists of a fabric weave, with an internal bladder and metallic bulkheads on either end. To mitigate model size, the fabric weave was simplified by representing it with shell elements. The task at hand is to represent the material behavior of the weave. The success of the model correlation is measured by comparing the four major modal frequencies of the analysis model to the four major modal frequencies of the test article. Given that only individual strap material properties were provided and material properties of the overall weave were not available, defining the material properties of the finite element model became very complex. First it was necessary to determine which material properties (modulus of elasticity in the hoop and longitudinal directions, shear modulus, Poisson's ratio, etc.) affected the modal frequencies. Then a Latin Hypercube of the parameter space was created to form an efficiently distributed finite case set. Each case was then analyzed with the results input into RSM. In the resulting response surface it was possible to see how each material parameter affected the modal frequencies of the analysis model. If the modal frequencies of the analysis model and its corresponding parameters match the test with acceptable accuracy, it can be said that the model correlation is successful.

  10. Repeat patient testing shows promise as a quality control method for veterinary hematology testing.

    Science.gov (United States)

    Flatland, Bente; Freeman, Kathleen P

    2018-03-05

    Repeat patient testing-based quality control (RPT-QC) is a potential method for veterinary laboratories (eg, that have a limited budget for quality commercial control material [QCM] or that wish to use material with a species-specific matrix). To determine whether total error (TE a ), probability of error detection (Ped), and probability of false rejection (Pfr) similar to that achievable with QC materials can be controlled using RPT-QC METHODS: Control limits (WBC, RBC, HGB, HCT, MCV, and PLT) for the Advia 120 (n = 23) and scil Vet ABC (n = 22) were calculated using data from normal canine specimens from a routine caseload. Specimens were measured at accession and again after 24 hours. Control limits were validated using 23 additional canine specimens tested similarly. Achievable TEa, Ped, and Pfr were investigated using the Westgard EZRules3 and compared to those achievable with commercial QCM. Theoretical performance of RPT-QC and commercial QCM-QC are similar for 1-3s with both n = 1 and 1-3s with n = 2 for all measurands and both instruments. Achievable TE a values for RPT-QC were close to ASVCP recommendations for most measurands; exceptions were PLT (both instruments) and WBC (scil Vet ABC). Repeat patient testing-based quality control advantages include a species-specific matrix, low-cost, and absence of QC material deterioration over time (since a fresh specimen is used each day). A potential disadvantage is daily access to normal canine specimens. A challenge is determining control limits, which has a subjective element. Further study is needed to confirm actual RPT-QC performance and to determine if RPT-QC with abnormal patient specimens is feasible. © 2018 American Society for Veterinary Clinical Pathology.

  11. Evaluation Of Isometric Exercise Test And Roll-Over Test As Methods Of Pregnancy

    Directory of Open Access Journals (Sweden)

    Mehdy Hassanzadeh Delui

    2005-05-01

    Full Text Available Background: The incidence of pregnancy induced hypertension (PIH which is one of the three main causes of maternal-neonatal morbidity and mortality is 5-7%, and prediction of this disorder is very important in maternal and neonatal health. Methods: The type of this study is analytical (comparative-prospective and its purpose is to evaluate the isometric exercise test (lET and roll-over test (ROT as methods ofPIH prediction. 116 nulliparaes, with study characteristics, after filling a questionaire and physical exam, underwent ROT, and then lET after 5 minutes, between 28-32 weeks of their pregnancy. The samples are followed up regularly until24 hr after delivery in Mashad university prenatal clinics and hospitals. Statistical analysis was done by SPSS with a: 0.05. Results: As a result, lET has a higher validity than ROT(sensitivity:78.9% vs. 47.4%, p<0.0001, specificity: 94.80 vs. 83.5%,p: 0.007,positivepredictivevalue: 75% vs. 36%,p: 0.0001, negative predictive value: 95.8% vs. 89%, p: 0.046, also validity of IETandROTtogetheris: sensitivity: 85.7%, specificity: 96.3%,PPV: 66.6% andNPV: 98.8%. Conclusion: The validity of lET in this study was shown to be higher than ROT, and by use of a very simple and cost -effective lET, we are able to predict PIH with the highest validity and if possible, use both tests in order to raise validity.

  12. Test Methods for Telemetry Systems and Subsystems. Volume 2: Test Methods for Telemetry Radio Frequency (RF) Subsystems

    Science.gov (United States)

    2012-09-01

    interference test is to measure the effect on bit error probability ( BEP ) of signals in adjacent frequency slots. The results will be a function of...is to have the two interfering signals 20 dB larger than the victim signal. Vary the attenuator that is common to the two interferers until the BEP ...measurement of bit error probability ( BEP ) improvement (or degradation) when signals are combined as compared with single channel operation. The BEP is

  13. Semi-natural test methods to evaluate fire safety of wall claddings: Update

    Directory of Open Access Journals (Sweden)

    Smolka Miroslav

    2016-01-01

    Full Text Available There are a number of test methods worldwide to evaluate fire safety of facades. An overview of available test methods implemented in fire safety codes was presented at the 1st Conference of Fire Safety of Facades in 2013. [1] Since then, a number of changes and developments occurred. The purpose of this paper is to present the updated global overview of facade fire spread test methods made for building regulations.

  14. Test Method for High β Particle Emission Rate of 63Ni Source Plate

    Directory of Open Access Journals (Sweden)

    ZHANG Li-feng

    2015-01-01

    Full Text Available For the problem of measurement difficulties of β particle emission rate of Ni-63 source plate used for Ni-63 betavoltaic battery, a relative test method of scintillation current method was erected according to the measurement principle of scintillation detector.β particle emission rate of homemade Ni-63 source plate was tested by the method, and the test results were analysed and evaluated, it was initially thought that scintillation current method was a feasible way of testing β particle emission rate of Ni-63 source plate with high β particle emission rate.

  15. Usability Testing as a Method to Refine a Health Sciences Library Website.

    Science.gov (United States)

    Denton, Andrea H; Moody, David A; Bennett, Jason C

    2016-01-01

    User testing, a method of assessing website usability, can be a cost-effective and easily administered process to collect information about a website's effectiveness. A user experience (UX) team at an academic health sciences library has employed user testing for over three years to help refine the library's home page. Test methodology used in-person testers using the "think aloud" method to complete tasks on the home page. Review of test results revealed problem areas of the design and redesign; further testing was effective in refining the page. User testing has proved to be a valuable method to engage users and provide feedback to continually improve the library's home page.

  16. Characterization of Material Stiffness on Injection Moulded Microspecimens Using Different Test Methods

    Directory of Open Access Journals (Sweden)

    Dietmar Drummer

    2014-01-01

    Full Text Available Injection moulding of polymer microparts can result in modified material behaviour due to process-induced changes in the internal properties. Thus, a transfer of the mechanical material properties in microparts, determined and valid on standardized test specimens, is only partially possible and should be verified on microtest specimens. This paper investigates both tensile and bending test methods for a suitable characterization of material stiffness in polymer microparts. For this purpose a down-scaled standard specimen is used and tested with different testing methods. The investigations reveal that the different testing methods result in comparable mechanical values. The effects of process-induced modified mechanical behaviour are observable in the investigated testing methods. Consequently, a microbending test is potentially a suitable method for characterizing material stiffness using microspecimens.

  17. Method modification of the Legipid® Legionella fast detection test kit.

    Science.gov (United States)

    Albalat, Guillermo Rodríguez; Broch, Begoña Bedrina; Bono, Marisa Jiménez

    2014-01-01

    Legipid(®) Legionella Fast Detection is a test based on combined magnetic immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella in water. The test is based on the use of anti-Legionella antibodies immobilized on magnetic microspheres. Target microorganism is preconcentrated by filtration. Immunomagnetic analysis is applied on these preconcentrated water samples in a final test portion of 9 mL. The test kit was certified by the AOAC Research Institute as Performance Tested Method(SM) (PTM) No. 111101 in a PTM validation which certifies the performance claims of the test method in comparison to the ISO reference method 11731-1998 and the revision 11731-2004 "Water Quality: Detection and Enumeration of Legionella pneumophila" in potable water, industrial water, and waste water. The modification of this test kit has been approved. The modification includes increasing the target analyte from L. pneumophila to Legionella species and adding an optical reader to the test method. In this study, 71 strains of Legionella spp. other than L. pneumophila were tested to determine its reactivity with the kit based on CEIA. All the strains of Legionella spp. tested by the CEIA test were confirmed positive by reference standard method ISO 11731. This test (PTM 111101) has been modified to include a final optical reading. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Two water matrixes were analyzed. Results show no statistically detectable difference between the test method and the reference culture method for the enumeration of Legionella spp. The relative level of detection was 93 CFU/volume examined (LOD50). For optical reading, the LOD was 40 CFU/volume examined and the LOQ was 60 CFU/volume examined. Results showed that the test Legipid Legionella Fast Detection is equivalent to the reference culture method for the enumeration of Legionella spp.

  18. Quality-control analytical methods: endotoxins: essential testing for pyrogens in the compounding laboratory, part 3: a simplified endotoxin test method for compounded sterile preparations.

    Science.gov (United States)

    Cooper, James F

    2011-01-01

    The first two parts of the IJPC series on endotoxin testing explained the nature of pyrogenic contamination and described various Limulus amebocyte lysate methods for detecting and measuring endotoxin levels with the bacterial endotoxin test described in the United States Pharmacopeia. This third article in that series describes the endotoxin test that is simplest to permorm for pharmacists who prefer to conduct an endotoxin assa at the time of compounding in the pharmacy setting.

  19. Comparison of manual mycobacteria growth indicator tube and epsilometer test with agar proportion method for susceptibility testing of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    N Karabulut

    2014-01-01

    Full Text Available Background and Objectives: Antimycobacterial susceptibility tests take weeks, and delayed therapy can lead to spread of Mycobacterium tuberculosis. Therefore, rapid, accurate and cost-effective methods are required for proper therapy selection. In this study, the Mycobacteria growth indicator tube (MGIT and epsilometer test (Etest methods were compared to the agar proportion method for susceptibility testing of Mycobacterium tuberculosis. Materials and Methods: The susceptibility tests against isoniazid (INH, rifampin (RIF, streptomycin (STM and ethambutol (ETM of 51 M. tuberculosis complex isolates were analyzed by the MGIT, Etest and agar proportion methods. Results: The concordance between MGIT/Etest and agar proportion methods was 98% for INH and 100% for RIF, STM, ETM. There were not statistically significant differences in results of the susceptibility tests between MGIT/Etest and the reference agar proportion method. Conclusion: The results have shown that MGIT and Etest methods can be used instead of the agar proportion method, because these two methods are more rapid and easier than the agar proportion method.

  20. Increasing Inferential Leverage in the Comparative Method: Placebo Tests in Small-"n" Research

    Science.gov (United States)

    Glynn, Adam N.; Ichino, Nahomi

    2016-01-01

    We delineate the underlying homogeneity assumption, procedural variants, and implications of the comparative method and distinguish this from Mill's method of difference. We demonstrate that additional units can provide "placebo" tests for the comparative method even if the scope of inference is limited to the two units under comparison.…

  1. Comparative testing of different methods for evaluation of Varroa destructor infestation of honey bee colonies

    Directory of Open Access Journals (Sweden)

    Nikolay D. Dobrynin

    2011-09-01

    Full Text Available Different methods for evaluation of the degree of Varroa destructor infestation of honey bee colonies were tested. The methods using in vivo evaluation were the most sparing for the bees but less precise. The methods using evaluation with the killing of the bees or brood were the most precise but less sparing for bees.

  2. Novel methods of inspiratory muscle training via the Test of Incremental Respiratory Endurance (TIRE).

    Science.gov (United States)

    Cahalin, Lawrence P; Arena, Ross

    2015-04-01

    The favorable effects of inspiratory muscle training (IMT) in health and disease are becoming much more apparent. A variety of IMT methods exist, but few studies have compared IMT methods. The purpose of this article is to review the methods and outcomes of the Test of Incremental Respiratory Endurance (TIRE).

  3. Tests of Measurement Invariance without Subgroups: A Generalization of Classical Methods

    Science.gov (United States)

    Merkle, Edgar C.; Zeileis, Achim

    2013-01-01

    The issue of measurement invariance commonly arises in factor-analytic contexts, with methods for assessment including likelihood ratio tests, Lagrange multiplier tests, and Wald tests. These tests all require advance definition of the number of groups, group membership, and offending model parameters. In this paper, we study tests of measurement…

  4. An Efficient Functional Test Generation Method For Processors Using Genetic Algorithms

    Science.gov (United States)

    Hudec, Ján; Gramatová, Elena

    2015-07-01

    The paper presents a new functional test generation method for processors testing based on genetic algorithms and evolutionary strategies. The tests are generated over an instruction set architecture and a processor description. Such functional tests belong to the software-oriented testing. Quality of the tests is evaluated by code coverage of the processor description using simulation. The presented test generation method uses VHDL models of processors and the professional simulator ModelSim. The rules, parameters and fitness functions were defined for various genetic algorithms used in automatic test generation. Functionality and effectiveness were evaluated using the RISC type processor DP32.

  5. Effect of Temperature and Time on Fecal Hemoglobin Stability in 5 Fecal Immunochemical Test Methods and One Guaiac Method.

    Science.gov (United States)

    Catomeris, Peter; Baxter, Nancy N; Boss, Sheila C; Paszat, Lawrence F; Rabeneck, Linda; Randell, Edward; Serenity, Mardie L; Sutradhar, Rinku; Tinmouth, Jill

    2018-01-01

    - Although promising for colorectal cancer screening, hemoglobin (Hb) stability remains a concern with fecal immunochemical tests. This study implemented a novel, standardized method to compare Hb stability across various fecal immunochemical tests. The method can be used to inform decisions when selecting a kit for use in colorectal cancer screening. In so doing, this work addressed a critical need for standardization in this field. - To compare the stability of Hb across 5 different immunochemical kits and one guaiac kit. - The stability of Hb was analyzed in collection devices inoculated with Hb-spiked feces and (1) stored at various temperatures (frozen, refrigerated, ambient, and elevated) for more than 60 days; (2) after undergoing 3 controlled, freeze-thaw cycles; and (3) after being transported by courier or postal services in uncontrolled temperature conditions from 3 locations in Ontario, Canada, to a central testing center. - The stability of Hb varied with time and temperature and by kit. Lower Hb recoveries occurred with increasing temperature and increasing time from sample collection to testing. Refrigeration provided the best stability, although results varied across kits (eg, from 4.2 days to >60 days before a prespecified threshold [<70% probability of the test results remaining positive] was reached). Freeze-thaw stability varied across kits and cycles (Hb recoveries: NS Plus [Alfresa Pharma, Chuo-ku, Osaka, Japan], 91.7% to 95.4%; OC Diana [Eiken Chemical, Taito-ku, Tokyo, Japan], 57.6% to 74.9%). Agreement regarding Hb levels before and after transportation varied across kits (from 57% to 100%). - Important differences in Hb stability were found across the included fecal immunochemical tests. These findings should inform practice-based and population-based colorectal cancer screening.

  6. Developmental Potential of Professional Test as a Method of Training Future Teachers

    OpenAIRE

    Neumoeva-Kolchedantseva E.V.

    2018-01-01

    The article is devoted to studying the developmental perspectives of the method of professional test. It offers an understanding of the professional test as a method of «locally immersing» students in professional activities at the stage of university training. It also describes an experience of evaluating professional tests aimed at mastering work actions defined in the professional standard for teachers. The article examines research data on the impact of the professional test on the develo...

  7. Effect of testing methods on the bond strength of resin to zirconia-alumina ceramic : microtensile versus shear test

    NARCIS (Netherlands)

    Valandro, Luiz F.; Ozcan, Mutlu; Amaral, Regina; Vanderlei, Aleska; Bottino, Marco A.

    2008-01-01

    This study tested the bond strength of a resin cement to a glass-infiltrated zirconia-alumina ceramic after three conditioning methods and using two test methods (shear-SBS versus microtensile-MTBS). Ceramic blocks for MTBS and ceramic disks for SBS were fabricated. Three surface conditioning (SC)

  8. Comparison of European Committee on Antimicrobial Susceptibility Testing (EUCAST) and Etest methods with the CLSI broth microdilution method for echinocandin susceptibility testing of Candida species.

    Science.gov (United States)

    Pfaller, M A; Castanheira, M; Diekema, D J; Messer, S A; Moet, G J; Jones, R N

    2010-05-01

    The antifungal broth microdilution (BMD) method of the European Committee on Antibiotic Susceptibility Testing (EUCAST) and the Etest agar diffusion method were compared with the Clinical and Laboratory Standards Institute (CLSI) BMD method M27-A3 for anidulafungin, caspofungin, and micafungin susceptibility testing of 133 clinical isolates of Candida species. The isolates were characterized for the presence or absence of fks1 and/or fks2 gene mutations and included 34 isolates of C. glabrata (4 mutant strains), 32 of C. albicans (1 mutant strain), 25 of C. parapsilosis, 19 of C. guilliermondii, 12 of C. tropicalis (2 mutant strains), and 11 of C. krusei. Excellent essential agreement (EA; within 2 dilutions) between the CLSI and EUCAST and CLSI and Etest MIC results was observed. The overall EA between the EUCAST and CLSI results ranged from 89.5% (caspofungin) to 99.2% (micafungin), whereas the EA between the Etest and CLSI results ranged from 90.2% (caspofungin) to 93.2% (anidulafungin). The categorical agreement (CA) between methods for each antifungal agent was assessed using previously determined epidemiological cutoff values (ECVs). Excellent CA (>90%) was observed for all comparisons between the EUCAST and CLSI results with the exceptions of C. glabrata and caspofungin (85.3%) and C. krusei and caspofungin (54.5%). The CA between the Etest and CLSI results was also excellent for all comparisons, with the exception of C. krusei and caspofungin (81.8%). All three methods were able to differentiate wild-type (WT) strains from those with fks mutations. With anidulafungin as the test reagent, the CLSI method identified 5 of 7 mutant strains, whereas the EUCAST method and the Etest identified 6 of 7 mutant strains. With either caspofungin or micafungin as the test reagent, the CLSI method identified all 7 mutant strains and the EUCAST method identified 6 of 7 mutant strains. The Etest identified all 7 mutant strains using caspofungin as the reagent. All three

  9. Comparison of European Committee on Antimicrobial Susceptibility Testing (EUCAST) and Etest Methods with the CLSI Broth Microdilution Method for Echinocandin Susceptibility Testing of Candida Species▿

    Science.gov (United States)

    Pfaller, M. A.; Castanheira, M.; Diekema, D. J.; Messer, S. A.; Moet, G. J.; Jones, R. N.

    2010-01-01

    The antifungal broth microdilution (BMD) method of the European Committee on Antibiotic Susceptibility Testing (EUCAST) and the Etest agar diffusion method were compared with the Clinical and Laboratory Standards Institute (CLSI) BMD method M27-A3 for anidulafungin, caspofungin, and micafungin susceptibility testing of 133 clinical isolates of Candida species. The isolates were characterized for the presence or absence of fks1 and/or fks2 gene mutations and included 34 isolates of C. glabrata (4 mutant strains), 32 of C. albicans (1 mutant strain), 25 of C. parapsilosis, 19 of C. guilliermondii, 12 of C. tropicalis (2 mutant strains), and 11 of C. krusei. Excellent essential agreement (EA; within 2 dilutions) between the CLSI and EUCAST and CLSI and Etest MIC results was observed. The overall EA between the EUCAST and CLSI results ranged from 89.5% (caspofungin) to 99.2% (micafungin), whereas the EA between the Etest and CLSI results ranged from 90.2% (caspofungin) to 93.2% (anidulafungin). The categorical agreement (CA) between methods for each antifungal agent was assessed using previously determined epidemiological cutoff values (ECVs). Excellent CA (>90%) was observed for all comparisons between the EUCAST and CLSI results with the exceptions of C. glabrata and caspofungin (85.3%) and C. krusei and caspofungin (54.5%). The CA between the Etest and CLSI results was also excellent for all comparisons, with the exception of C. krusei and caspofungin (81.8%). All three methods were able to differentiate wild-type (WT) strains from those with fks mutations. With anidulafungin as the test reagent, the CLSI method identified 5 of 7 mutant strains, whereas the EUCAST method and the Etest identified 6 of 7 mutant strains. With either caspofungin or micafungin as the test reagent, the CLSI method identified all 7 mutant strains and the EUCAST method identified 6 of 7 mutant strains. The Etest identified all 7 mutant strains using caspofungin as the reagent. All three

  10. Quantitative Evaluation of gamma-Spectrum Analysis Methods using IAEA Test Spectra

    DEFF Research Database (Denmark)

    Nielsen, Sven Poul

    1982-01-01

    A description is given of a γ-spectrum analysis method based on nonlinear least-squares fitting. The quality of the method is investigated by using statistical tests on the results from analyses of IAEA test spectra. By applying an empirical correction factor of 0.75 to the calculated peak-area u...

  11. 40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B

    Science.gov (United States)

    2010-07-01

    ... methodology of the test methods. It should be clearly understood that unless otherwise identified all such... deviations from the test methods without obtaining prior approval does so at the risk of subsequent... bottles with Teflon screw cap liners to store impinger samples. 6.3Sample Preparation and Analysis. The...

  12. A Review of External Pressure Testing Techniques for Shells including a Novel Volume-Control Method

    NARCIS (Netherlands)

    Mackay, J.R.; Van Keulen, F.

    2009-01-01

    A review of conventional testing methods for applying external hydrostatic pressure to buckling-critical shells is presented. A new “volume-control” pressure testing method, aimed at preventing catastrophic specimen failures and improving control of specimen deformation near the critical load, is

  13. Evaluation of seed health testing methods for the detection of seed ...

    African Journals Online (AJOL)

    The efficiency of four seed health testing techniques namely the blotter, deep- freezing blotter, ragdoll and agar plate methods in detecting seed-borne fungi of African yam bean, Sphenostylis stenocarpa (Hochst ex. A. Rich) Harms seeds was evaluated. The blotter method was found to be the most suitable testing technique ...

  14. Porosity testing methods for the quality assessment of selective laser melted parts

    NARCIS (Netherlands)

    Wits, Wessel W.; Carmignato, Simone; Zanini, Filippo; Vaneker, Thomas H.J.

    2016-01-01

    This study focuses on the comparison of porosity testing methods for the quality assessment of selective laser melted parts. Porosity is regarded as important quality indicator in metal additive manufacturing. Various destructive and non-destructive testing methods are compared, ranging from global

  15. 40 CFR 63.1414 - Test methods and emission estimation equations.

    Science.gov (United States)

    2010-07-01

    ... equations. 63.1414 Section 63.1414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... § 63.1414 Test methods and emission estimation equations. (a) Test methods. When required to conduct a... rate for a batch emission episode shall be calculated using Equation 1 of this section: ER20JA00.007...

  16. A Review of Methods for Detection of Test and Item Bias.

    Science.gov (United States)

    Breunig, Nancy A.

    Few issues have provoked as much controversy as the methods for detecting item and test bias. A recent illustration of the controversy surrounding this issue could be seen in the emotional reactions to the publication of "The Bell Curve." This paper reviews methods of evaluating both item and test bias. Small heuristic data sets are…

  17. Autogenous shrinkage of Ducorit S5R ASTM C 1698-09 test method

    DEFF Research Database (Denmark)

    Damkilde, Lars

    The report deals with experimental measurement of autogenous shrinkage of Ducorit S5R according to the test method ASTM C 1698-09. This test method measures the bulk strain of a sealed cementitious specimen, at constant temperature and not subjected to external forces, from the time of final...

  18. Validation of Alternative In Vitro Methods to Animal Testing: Concepts, Challenges, Processes and Tools.

    Science.gov (United States)

    Griesinger, Claudius; Desprez, Bertrand; Coecke, Sandra; Casey, Warren; Zuang, Valérie

    This chapter explores the concepts, processes, tools and challenges relating to the validation of alternative methods for toxicity and safety testing. In general terms, validation is the process of assessing the appropriateness and usefulness of a tool for its intended purpose. Validation is routinely used in various contexts in science, technology, the manufacturing and services sectors. It serves to assess the fitness-for-purpose of devices, systems, software up to entire methodologies. In the area of toxicity testing, validation plays an indispensable role: "alternative approaches" are increasingly replacing animal models as predictive tools and it needs to be demonstrated that these novel methods are fit for purpose. Alternative approaches include in vitro test methods, non-testing approaches such as predictive computer models up to entire testing and assessment strategies composed of method suites, data sources and decision-aiding tools. Data generated with alternative approaches are ultimately used for decision-making on public health and the protection of the environment. It is therefore essential that the underlying methods and methodologies are thoroughly characterised, assessed and transparently documented through validation studies involving impartial actors. Importantly, validation serves as a filter to ensure that only test methods able to produce data that help to address legislative requirements (e.g. EU's REACH legislation) are accepted as official testing tools and, owing to the globalisation of markets, recognised on international level (e.g. through inclusion in OECD test guidelines). Since validation creates a credible and transparent evidence base on test methods, it provides a quality stamp, supporting companies developing and marketing alternative methods and creating considerable business opportunities. Validation of alternative methods is conducted through scientific studies assessing two key hypotheses, reliability and relevance of the

  19. Analysis using formal method and testing technique for the processor module for safety-critical application

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J. Y.; Choi, B. J.; Song, H. J.; Hwang, D. Y.; Song, G. H.; Lee, H. [Korea University, Seoul (Korea, Republic of)

    2008-06-15

    This research is on help develop nuclear power plant control system, through the requirement specification and verification method development. As the result of applying the test method, a test standard was obtain through test documentation writing support and a test document reflecting the standard test activities based on the test standard. The specification and verification of the pCOS system and the unified testing documentation and execution helps the entire project to progress and enable us to achieve necessary documents and technology to develop a safety critical system.

  20. Multifrequency excitation method for rapid and accurate dynamic test of micromachined gyroscope chips.

    Science.gov (United States)

    Deng, Yan; Zhou, Bin; Xing, Chao; Zhang, Rong

    2014-10-17

    A novel multifrequency excitation (MFE) method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE) method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  1. Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the measurement of solar photometric transmittance of materials in sheet form. Solar photometric transmittance is measured using a photometer (illuminance meter) in an enclosure with the sun and sky as the source of radiation. The enclosure and method of test is specified in Test Method E 1175 (or Test Method E 1084). 1.2 The purpose of this test method is to specify a photometric sensor to be used with the procedure for measuring the solar photometric transmittance of sheet materials containing inhomogeneities in their optical properties. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  3. Standard test method for plane-strain (Chevron-Notch) fracture toughness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers the determination of plane-strain (chevron-notch) fracture toughnesses, KIv or KIvM, of metallic materials. Fracture toughness by this method is relative to a slowly advancing steady state crack initiated at a chevron-shaped notch, and propagating in a chevron-shaped ligament (Fig. 1). Some metallic materials, when tested by this method, exhibit a sporadic crack growth in which the crack front remains nearly stationary until a critical load is reached. The crack then becomes unstable and suddenly advances at high speed to the next arrest point. For these materials, this test method covers the determination of the plane-strain fracture toughness, KIvj or KIvM, relative to the crack at the points of instability. Note 1—One difference between this test method and Test Method E 399 (which measures KIc) is that Test Method E 399 centers attention on the start of crack extension from a fatigue precrack. This test method makes use of either a steady state slowly propagating crack, or a...

  4. Standard Test Methods for Solar Energy Transmittance and Reflectance (Terrestrial) of Sheet Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover the measurement of solar energy transmittance and reflectance (terrestrial) of materials in sheet form. Method A, using a spectrophotometer, is applicable for both transmittance and reflectance and is the referee method. Method B is applicable only for measurement of transmittance using a pyranometer in an enclosure and the sun as the energy source. Specimens for Method A are limited in size by the geometry of the spectrophotometer while Method B requires a specimen 0.61 m2 (2 ft2). For the materials studied by the drafting task group, both test methods give essentially equivalent results. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Quantification of the borderline range and implications for evaluating non-animal testing methods' precision.

    Science.gov (United States)

    Leontaridou, Maria; Urbisch, Daniel; Kolle, Susanne N; Ott, Katharina; Mulliner, Denis S; Gabbert, Silke; Landsiedel, Robert

    2017-02-23

    Testing methods to assess the skin sensitisation potential of a substance usually use threshold criteria to dichotomise continuous experimental read-outs into yes/no conclusions. The threshold criteria are prescribed in the respective OECD test guidelines and the conclusion is used for regulatory hazard assessment, i.e. classification and labelling of the substance. We can identify a borderline range (BR) around the classification threshold within which test results are non-conclusive due to a testing method's biological and technical variability. We quantify BRs in the prediction models of the non-animal testing methods DPRA, LuSens and h-CLAT, and of the animal test LLNA, respectively. Depending on the size of the BR we find that between 6% and 28% of the substances in the sets tested with these methods were considered borderline. If the results of individual non-animal test methods are combined into integrated testing strategies (ITS), borderline test results of individual tests can also affect the overall assessment of the skin sensitisation potential of the testing strategy. This was analysed for the '2-out-of-3' ITS: Four out of 40 substances (10%) were considered borderline. Based on our findings we propose expanding the standard binary classification of substances into 'positive'/'negative' or 'hazardous'/'non-hazardous' by adding a 'borderline' or 'non-conclusive' alert for cases where test results fall within the borderline range.

  6. Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 9 Qualification

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Pareizs, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Coleman, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Young, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Brown, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-05-10

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt or SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.

  7. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover procedures for subsampling and for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride UF6. Most of these test methods are in routine use to determine conformance to UF6 specifications in the Enrichment and Conversion Facilities. 1.2 The analytical procedures in this document appear in the following order: Note 1—Subcommittee C26.05 will confer with C26.02 concerning the renumbered section in Test Methods C761 to determine how concerns with renumbering these sections, as analytical methods are replaced with stand-alone analytical methods, are best addressed in subsequent publications. Sections Subsampling of Uranium Hexafluoride 7 - 10 Gravimetric Determination of Uranium 11 - 19 Titrimetric Determination of Uranium 20 Preparation of High-Purity U3O 8 21 Isotopic Analysis 22 Isotopic Analysis by Double-Standard Mass-Spectrometer Method 23 - 29 Determination of Hydrocarbons, Chlorocarbons, and Partially Substitut...

  8. Direct antimicrobial drug susceptibility testing of Mycobacterium tuberculosis by the radiometric method

    Energy Technology Data Exchange (ETDEWEB)

    Libonati, J.P.; Stager, C.E.; Davis, J.R.; Siddiqi, S.H.

    1988-05-01

    Direct-drug-susceptibility tests were performed on clinical specimens positive for acid-fast bacilli by either Ziehl-Neelsen or fluorochrome staining. The results of conventional agar dilution and a modified radiometric (BACTEC) method were compared. A total of 580 smear-positive specimens were tested by the BACTEC method at three separate sites. Three hundred and seventy-seven of these were culture positive for M. tuberculosis, and 343 (91%) yielded acceptable direct-susceptibility-test results. We used the conventional method to determine that 343 of 519 smear-positive specimens were culture positive for M. tuberculosis, and 212 (62%) produced acceptable results within 3 wks. Conventional results were reported in 3-4 wks, while the time required to obtain results with the BACTEC method ranged from 5 to 21 days (average 11.5 days). Results indicate that the radiometric method provides reportable results more frequently with time savings as compared to the conventional method.

  9. Standard test method for exfoliation corrosion susceptibility in 2XXX and 7XXX Series Aluminum Alloys (EXCO Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for constant immersion exfoliation corrosion (EXCO) testing of high-strength 2XXX and 7XXX series aluminum alloys. Note 1—This test method was originally developed for research and development purposes; however, it is referenced, in specific material specifications, as applicable for evaluating production material (refer to Section 14 on Precision and Bias). 1.2 This test method applies to all wrought products such as sheet, plate, extrusions, and forgings produced from conventional ingot metallurgy process. 1.3 This test method can be used with any form of specimen or part that can be immersed in the test solution. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Using a fuzzy comprehensive evaluation method to determine product usability: A test case.

    Science.gov (United States)

    Zhou, Ronggang; Chan, Alan H S

    2017-01-01

    In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.

  11. A model for the harmonisation of test results of different quantitative D-dimer methods.

    Science.gov (United States)

    Meijer, Piet; Haverkate, Frits; Kluft, Cornelis; de Moerloose, Philippe; Verbruggen, Bert; Spannagl, Michael

    2006-03-01

    The numerical test results of different D-dimer assays vary widely. Because of the complexity of the analyte of target as well as the variability in specificity of different D-dimer assays, only harmonisation of the test results seems to be feasible. The use of a single conversion factor does not take into account for several methods the lack of commutability between test results and consensus values at different D-dimer levels. This is probably related to the mutually different response of methods to high and low levels. We therefore designed a harmonisation model based on the transformation of a method-specific regression line to a reference regression line. We used the data for the measurement of a set of plasma samples with different D-dimer levels by 353 different laboratories using 7 of the most frequently used quantitative D-dimer methods. For each method we calculated the method-specific consensus value for each sample. The overall median value was also estimated. Per method linear regression was applied throughout the method-specific consensus values using the amount of patient pooled plasma added to the different plasma samples as the independent variable. The line through the overall median values of all 7 methods was used as the reference line. Harmonisation between the methods was obtained by transformation of the method-specific regression line to the reference line. This harmonisation resulted in a reduction of the variability between the method-specific consensus values from about 75% to about 5.5%. Clinical validation of this concept had shown significant improvement of the test result comparability. We conclude that this model is a feasible approach in the harmonisation of D-dimer methods. If the harmonisation procedure is included in the calibration procedure by the manufacturers, customers will automatically obtain harmonised test results.

  12. An Efficient Method for Automatic Generation of Linearly Independent Paths in White-box Testing

    Directory of Open Access Journals (Sweden)

    Xinyang Wang

    2015-04-01

    Full Text Available Testing is the one of most significant quality assurance measures for software. It has been shown that the software testing is one of the most critical and important phases in the life cycle of software engineering. In general, software testing takes around 40-60% of the effort, time and cost. Structure-oriented test methods define test cases on the basis of the internal program structures and are widely used. Path-based test is one of the important Structure-oriented test methods during software development. However, there is still lack of automatic and highly efficient tool for generating basic paths in white-box testing. In view of this, an automatic and efficient method for generating basic paths is proposed in this paper. This method firstly transforms the source-code program into corresponding control flow graph (CFG. By modifying the original CFG to a strongly connected graph, a new algorithm (ABPC is designed to automatically construct all basic paths. The ABPC algorithm has computational complexity linear to the number of total edges and nodes in the CFG. Through performance evaluation of many examples, it is shown that the proposed method is correct and scalable to very large test cases. The proposed method can be applied to basis path testing easily.

  13. Standard Test Methods for Photovoltaic Modules in Cyclic Temperature and Humidity Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods provide procedures for stressing photovoltaic modules in simulated temperature and humidity environments. Environmental testing is used to simulate aging of module materials on an accelerated basis. 1.2 Three individual environmental test procedures are defined by these test methods: a thermal cycling procedure, a humidity-freeze cycling procedure, and an extended duration damp heat procedure. Electrical biasing is utilized during the thermal cycling procedure to simulate stresses that are known to occur in field-deployed modules. 1.3 These test methods define mounting methods for modules undergoing environmental testing, and specify parameters that must be recorded and reported. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 Any of the individual environmental tests may be performed singly, or may be combined into a test sequence with other environmental or non-envir...

  14. Perturbation methods

    CERN Document Server

    Nayfeh, Ali H

    2008-01-01

    1. Introduction 1 2. Straightforward Expansions and Sources of Nonuniformity 23 3. The Method of Strained Coordinates 56 4. The Methods of Matched and Composite Asymptotic Expansions 110 5. Variation of Parameters and Methods of Averaging 159 6. The Method of Multiple Scales 228 7. Asymptotic Solutions of Linear Equations 308 References and Author Index 387 Subject Index 417

  15. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  16. "Comparison of some Structural Analyses Methods used for the Test Pavement in the Danish Road Testing Machine

    DEFF Research Database (Denmark)

    Baltzer, S.; Zhang, W.; Macdonald, R.

    1998-01-01

    A flexible test pavement, instrumented to measure stresses and strains in the three primary axes with the upper 400 mm of the subgrade, has been constructed and load tested in the Danish Road Testing Machine (RTM). One objective of this research, which is part of the International Pavement Subgrade...... three test series, 50000 load repetitions were applied at each load level, and the test chamber temperature was maintained at approximately 25 degree C.Instruments installed in the test pavement included: Strain measuring sensors (LVDT Soil Strain Deformation Transducers and Asphalt Strain Gauges), Soil...... methods used for the RTM test pavement with data from FWD testing undertaken after the construction and loading programmes. Multilayer linear elastic forward and backcalculation methods, a finite element program and MS Excel spreadsheet based methods are compared....

  17. A low cost method of testing compression-after-impact strength of composite laminates

    Science.gov (United States)

    Nettles, Alan T.

    1991-01-01

    A method was devised to test the compression strength of composite laminate specimens that are much thinner and wider than other tests require. The specimen can be up to 7.62 cm (3 in) wide and as thin as 1.02 mm (.04 in). The best features of the Illinois Institute of Technology Research Institute (IITRI) fixture are combined with an antibuckling jig developed and used at the University of Dayton Research Institute to obtain a method of compression testing thin, wide test coupons on any 20 kip (or larger) loading frame. Up to 83 pct. less composite material is needed for the test coupons compared to the most commonly used compression-after-impact (CAI) tests, which calls for 48 ply thick (approx. 6.12 mm) test coupons. Another advantage of the new method is that composite coupons of the exact lay-up and thickness of production parts can be tested for CAI strength, thus yielding more meaningful results. This new method was used to compression test 8 and 16 ply laminates of T300/934 carbon/epoxy. These results were compared to those obtained using ASTM standard D 3410-87 (Celanese compression test). CAI testing was performed on IM6/3501-6, IM7/SP500 and IM7/F3900. The new test method and associated fixture work well and is a valuable asset to MSFC's damage tolerance program.

  18. Question-answering method for surveillance tests in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Ohga, Yukiharu; Ito, Tetsuo (Hitachi Ltd., Ibaraki (Japan). Energy Research Lab.)

    1989-12-01

    A question-answering method for plant maintenance and operation has been developed to improve man-machine communications in nuclear power plants. Applying the method, program was written and tests were performed on consultations about surveillance tests. A feature of the method in input sentence analysis is use of semantic analysis by demand identification rules and information retrieval frames. The former prepares patterns of sentences for each demand and the letter, the required information and its retrieval method. In the knowledge base lookup, the knowledge base for surveillance tests is prepared in frames and a commonsense algorithm (CSA) which represents dynamic knowledge by events and links. Question-answering tests were performed and it was found that the present method can analyze various styles of sentences, including omission of postpositions and verbs, as well as get uninputted information by referring to the dialog history etc. (author).

  19. Cooperative system and method using mobile robots for testing a cooperative search controller

    Science.gov (United States)

    Byrne, Raymond H.; Harrington, John J.; Eskridge, Steven E.; Hurtado, John E.

    2002-01-01

    A test system for testing a controller provides a way to use large numbers of miniature mobile robots to test a cooperative search controller in a test area, where each mobile robot has a sensor, a communication device, a processor, and a memory. A method of using a test system provides a way for testing a cooperative search controller using multiple robots sharing information and communicating over a communication network.

  20. Allergic Contact Dermatitis to Ophthalmic Medications: Relevant Allergens and Alternative Testing Methods.

    Science.gov (United States)

    Grey, Katherine R; Warshaw, Erin M

    Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.

  1. The anchors of steel wire ropes, testing methods and their results

    Directory of Open Access Journals (Sweden)

    J. Krešák

    2012-10-01

    Full Text Available The present paper introduces an application of the acoustic and thermographic method in the defectoscopic testing of immobile steel wire ropes at the most critical point, the anchor. First measurements and their results by these new defectoscopic methods are shown. In defectoscopic tests at the anchor, the widely used magnetic method gives unreliable results, and therefore presents a problem for steel wire defectoscopy. Application of the two new methods in the steel wire defectoscopy at the anchor point will enable increased safety measures at the anchor of steel wire ropes in bridge, roof, tower and aerial cable lift constructions.

  2. In-situ test methods for assessment of surface pH of corroding sewer pipes

    DEFF Research Database (Denmark)

    Nielsen, Asbjørn Haaning; Vollertsen, Jes

    A method for measuring the surface pH of corroding concrete was developed in the lab and tested in the field. The method is based on direct application of pH indicator solution on the corroding surfaces. Comparison against point measurements using a flat surface pH electrode (flatrode) confirmed...... the accuracy of the method. Blind testing of concrete specimens exposed to different acid concentrations demonstrated that it was possible to determine the surface pH within ±0.5 pH units in the pH range of one to five. The developed method provides a simple and reliable estimate on the extent of concrete...

  3. Numerical test of the open void method of slide line with unstructured polygon grids

    Science.gov (United States)

    Lin, Wenzhou; Lin, Zhong; Liu, Quan

    2017-07-01

    An open void method of slide line is developed based on unstructured arbitrary polygon grids. An method of distinguishing open or closed void state of node and grid, and calculation method of velocity of node in slide line is given with open or closed state. Many conditions including different kinds of grids, different velocity and multi-medium are simulated in a test of a metallic flyer impacting another flyer and then separating. A test of Detonation driving metallic flyer are is simulated, which prove the rationality and adaptability of method.

  4. Correlating the EMC analysis and testing methods for space systems in MIL-STD-1541A

    Science.gov (United States)

    Perez, Reinaldo J.

    A study was conducted to improve the correlation between the electromagnetic compatibility (EMC) analysis models stated in MIL-STD-1541A and the suggested testing methods used for space systems. The test and analysis methods outlined in MIL-STD-1541A are described, and a comparative assessment of testing and analysis techniques as they relate to several EMC areas is presented. Suggestions on present analysis and test methods are introduced to harmonize and bring the analysis and testing tools in MIL-STD-1541A into closer agreement. It is suggested that test procedures in MIL-STD-1541A must be improved by providing alternatives to the present use of shielded enclosures as the primary site for such tests. In addition, the alternate use of anechoic chambers and open field test sites must be considered.

  5. Test case set generation method on MC/DC based on binary tree

    Science.gov (United States)

    Wang, Jun-jie; Zhang, Bo; Chen, Yuan

    2013-03-01

    Exploring efficient, reliable test case design methods has been tester pursuit of the goal. Along with the aerospace software logic complexity of improving and software scale enlarging, this requirement also gets more compelling. Test case design techniques suited for MC/DC improved test case design efficiency, increase the test coverage. It is suitable to test the software that logical relationship is complicated comparatively. Some software test tools provide the function to calculate the test coverage. And it can assess the test cases whether on the MC/DC or not. But the software tester needs the reverse thinking. The paper puts forward that design the test case by Unique-cause and Masking approach. And it proposes automatic generation method of test case on MC/DC. It improved the efficiency and correctness of generation the test case set on DC/DC.

  6. [Test method for lead in metal utensils for food contact use].

    Science.gov (United States)

    Mutsuga, Motoh; Yotsuyanagi, Michiyo; Kawamura, Yoko

    2011-01-01

    We compared test methods for measurement of lead in metal utensils using flame-atomic absorption spectroscopy (AAS), graphite furnace-AAS (GFAA), inductively coupled plasma atomic emission spectrometry (ICP) and X-ray fluorescence analysis (XRF). The procedure for preparation of the test solution was improved. A 100 mg of sample was dissolved in 2.5 mL of HCl and HNO(3) (3 : 1) mixture (in the case of titanium sample, dissolved in HCl). Stock solution was prepared by diluting to 50 mL with water. The test solution was prepared by diluting with 0.1 mol/L HNO(3). The recoveries of lead added to various kinds of metal reagent at the level of 0.1% were 90-118%. When standard materials which contained lead at the level of 0.0098-0.11% were measured, the measured values were in close agreement with the standard values. These procedures are applicable to aluminum, iron, stainless steel, copper, tin and titanium products. The AAS method, GFAA method and ICP method were suitable as the lead test methods. Moreover, the XRF method was useful as a screening method or a simple determination method. The ICP method was used to determine the lead contents in 22 kinds of commercial metal utensils, and 0.011-0.040% of lead were detected in 6 samples.

  7. Correlation Test Application of Supplier’s Ranking Using TOPSIS and AHP-TOPSIS Method

    Directory of Open Access Journals (Sweden)

    Ika Yuniwati

    2016-05-01

    Full Text Available The supplier selection process can be done using multi-criteria decision making (MCDM methods in firms. There are many MCDM Methods, but firms must choose the method suitable with the firm condition. Company A has analyzed supplier’s ranking using TOPSIS method. TOPSIS method has a marjor weakness in its subjective weighting. This flaw is overcome using AHP method weighting having undergone a consistency test. In this study, the comparison of supplier’s ranking using TOPSIS and AHP-TOPSIS method used correlation test. The aim of this paper is to determine different result from two methods. Data in suppliers’ ranking is ordinal data, so this process used Spearman’s rank and Kendall’s tau b correlation. If most of the ranked scored are same, Kendall’s tau b correlation should be used. The other way, Spearman rank should be used. The result of this study is that most of the ranked scored are different, so the process used Spearman rank p-value of Spearman’s rank correlation of 0.505. It is greater than 0.05, means there is no statistically significant correlation between two methods. Furthermore, increment or decrement of supplier’s ranking in one method is not significantly related to the increment or decrement of supplier’s ranking in the second method

  8. [Implication of inverse-probability weighting method in the evaluation of diagnostic test with verification bias].

    Science.gov (United States)

    Kang, Leni; Zhang, Shaokai; Zhao, Fanghui; Qiao, Youlin

    2014-03-01

    To evaluate and adjust the verification bias existed in the screening or diagnostic tests. Inverse-probability weighting method was used to adjust the sensitivity and specificity of the diagnostic tests, with an example of cervical cancer screening used to introduce the Compare Tests package in R software which could be implemented. Sensitivity and specificity calculated from the traditional method and maximum likelihood estimation method were compared to the results from Inverse-probability weighting method in the random-sampled example. The true sensitivity and specificity of the HPV self-sampling test were 83.53% (95%CI:74.23-89.93)and 85.86% (95%CI: 84.23-87.36). In the analysis of data with randomly missing verification by gold standard, the sensitivity and specificity calculated by traditional method were 90.48% (95%CI:80.74-95.56)and 71.96% (95%CI:68.71-75.00), respectively. The adjusted sensitivity and specificity under the use of Inverse-probability weighting method were 82.25% (95% CI:63.11-92.62) and 85.80% (95% CI: 85.09-86.47), respectively, whereas they were 80.13% (95%CI:66.81-93.46)and 85.80% (95%CI: 84.20-87.41) under the maximum likelihood estimation method. The inverse-probability weighting method could effectively adjust the sensitivity and specificity of a diagnostic test when verification bias existed, especially when complex sampling appeared.

  9. Status and Prospect of Test Methods of Quality Silicone Water Repellent for Protecting Reinforced Concrete

    Energy Technology Data Exchange (ETDEWEB)

    Sun, H. Y.; Yuan, Z. Y.; Yang, Z.; Shan, G. L. [Nanjing Hydraulic Research Institute, Nanjing (China); Shen, M. X. [Hehai University, Nanjing (China)

    2017-06-15

    Impregnating with quality silicone water repellent on the concrete surface is an effective method of protecting concrete. Quality silicone water repellent has been widely used in the engineering profession because of its desirable properties such as hydrophobicity, keeping concrete breathable and preserving the original appearance of the concrete. The companies in China that produce silicone water repellent are listed. Test methods in the specifications or standards about silicone water repellent in China are summed. The test methods relative to durability of concrete impregnated with silicone water repellent (such as resistant to chloride ion penetration, resistant to alkali, resistance to freezing and thawing and weather ability etc.) and the constructive quality (such as water absorption rate, impregnating depth and the dry velocity coefficient etc.) are compared and analyzed. The results indicate that there are differences among test methods relative to different specifications with the same index and therefore, confusion has ensued when selecting test methods. All test methods with the exception of the method of water absorption rate by using a Karsten flask are not non-destructive methods or conducted in a laboratory. Finally, further research on silicone water repellent during application is proposed.

  10. A Novel Vibration Mode Testing Method for Cylindrical Resonators Based on Microphones

    Directory of Open Access Journals (Sweden)

    Yongmeng Zhang

    2015-01-01

    Full Text Available Non-contact testing is an important method for the study of the vibrating characteristic of cylindrical resonators. For the vibratory cylinder gyroscope excited by piezo-electric electrodes, mode testing of the cylindrical resonator is difficult. In this paper, a novel vibration testing method for cylindrical resonators is proposed. This method uses a MEMS microphone, which has the characteristics of small size and accurate directivity, to measure the vibration of the cylindrical resonator. A testing system was established, then the system was used to measure the vibration mode of the resonator. The experimental results show that the orientation resolution of the node of the vibration mode is better than 0.1°. This method also has the advantages of low cost and easy operation. It can be used in vibration testing and provide accurate results, which is important for the study of the vibration mode and thermal stability of vibratory cylindrical gyroscopes.

  11. Standardization of a broth microdilution susceptibility testing method to determine minimum inhibitory concentrations of aquatic bacteria

    DEFF Research Database (Denmark)

    Miller, R.A.; Walker, R.D.; Carson, J.

    2005-01-01

    are below 35 degrees C. Methods and QC ranges defined in this study will enable aquatic animal disease researchers to reliably compare quantitative susceptibility testing data between laboratories, and will be used to ensure both precision and inter-laboratory harmonization...... antimicrobial susceptibility testing methods for bacterial isolates from aquatic animal species. QC ranges were established for Escherichia coli ATCC 25922 and Aeromonas salmonicida subsp. salmonicida ATCC 33658 when testing at 22, 28 and 35 degrees C (E. coli only) for 10 different antimicrobial agents......-Hinton broth. These QC ranges were accepted by the CLSI/NCCLS Subcommittee on Veterinary Antimicrobial Susceptibility Testing in January 2004. This broth microdilution testing method represents the first standardized method for determining MICs of bacterial isolates whose preferred growth temperatures...

  12. Standard test methods for conducting creep, creep-rupture, and stress-rupture tests of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 These test methods cover the determination of the amount of deformation as a function of time (creep test) and the measurement of the time for fracture to occur when sufficient force is present (rupture test) for materials when under constant tensile forces at constant temperature. It also includes the essential requirements for testing equipment. For information of assistance in determining the desirable number and duration of tests, reference should be made to the product specification. 1.2 These test methods list the information which should be included in reports of tests. The intention is to ensure that all useful and readily available information is transmitted to interested parties. Reports receive special attention for the following reasons: (1) results from different, recognized procedures vary significantly; therefore, identification of methods used is important; (2) later studies to establish important variables are often hampered by the lack of detailed information in published reports; (3) t...

  13. USING COMPUTER-BASED TESTING AS ALTERNATIVE ASSESSMENT METHOD OF STUDENT LEARNING IN DISTANCE EDUCATION

    Directory of Open Access Journals (Sweden)

    Amalia SAPRIATI

    2010-04-01

    Full Text Available This paper addresses the use of computer-based testing in distance education, based on the experience of Universitas Terbuka (UT, Indonesia. Computer-based testing has been developed at UT for reasons of meeting the specific needs of distance students as the following: Ø students’ inability to sit for the scheduled test, Ø conflicting test schedules, and Ø students’ flexibility to take examination to improve their grades. In 2004, UT initiated a pilot project in the development of system and program for computer-based testing method. Then in 2005 and 2006 tryouts in the use of computer-based testing methods were conducted in 7 Regional Offices that were considered as having sufficient supporting recourses. The results of the tryouts revealed that students were enthusiastic in taking computer-based tests and they expected that the test method would be provided by UT as alternative to the traditional paper and pencil test method. UT then implemented computer-based testing method in 6 and 12 Regional Offices in 2007 and 2008 respectively. The computer-based testing was administered in the city of the designated Regional Office and was supervised by the Regional Office staff. The development of the computer-based testing was initiated with conducting tests using computers in networked configuration. The system has been continually improved, and it currently uses devices linked to the internet or the World Wide Web. The construction of the test involves the generation and selection of the test items from the item bank collection of the UT Examination Center. Thus the combination of the selected items compromises the test specification. Currently UT has offered 250 courses involving the use of computer-based testing. Students expect that more courses are offered with computer-based testing in Regional Offices within easy access by students.

  14. Standard Test Method for Electrical Performance of Concentrator Terrestrial Photovoltaic Modules and Systems Under Natural Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of photovoltaic concentrator modules and systems under natural sunlight using a normal incidence pyrheliometer. 1.2 The test method is limited to module assemblies and systems where the geometric concentration ratio specified by the manufacturer is greater than 5. 1.3 This test method applies to concentrators that use passive cooling where the cell temperature is related to the air temperature. 1.4 Measurements under a variety of conditions are allowed; results are reported under a select set of concentrator reporting conditions to facilitate comparison of results. 1.5 This test method applies only to concentrator terrestrial modules and systems. 1.6 This test method assumes that the module or system electrical performance characteristics do not change during the period of test. 1.7 The performance rating determined by this test method applies only at the period of the test, and implies no past or future performance level. 1.8...

  15. Susceptibility testing of filamentous fungi to amphotericin B by a rapid radiometric method

    Energy Technology Data Exchange (ETDEWEB)

    Merz, W.G.; Fay, D.; Thumar, B.; Dixon, D.

    1984-01-01

    A rapid, radiometric method was developed to determine the susceptibility of filamentous fungi to amphotericin B. The rapid, radiometric method depended on measurement of the inhibition of /sup 24/CO/sub 2/ production in the presence of amphotericin B. Thirty isolates of filamentous fungi were tested by the rapid, radiometric method and a reference agar dilution method. There was 93% agreement between the two methods when an 80% or greater decrease in CO/sub 2/ production was used to calculate the minimal inhibitory concentration with the rapid, radiometric method. Minimal inhibitory concentrations, based on 80% decrease of CO/sub 2/ production, were achieved within 24 h of incubation with all of the fungi tested.

  16. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Science.gov (United States)

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  17. A Design Method of Saturation Test Image Based on CIEDE2000

    Directory of Open Access Journals (Sweden)

    Yang Yang

    2012-01-01

    Full Text Available In order to generate color test image consistent with human perception in aspect of saturation, lightness, and hue of image, we propose a saturation test image design method based on CIEDE2000 color difference formula. This method exploits the subjective saturation parameter C′ of CIEDE2000 to get a series of test images with different saturation but same lightness and hue. It is found experimentally that the vision perception has linear relationship with the saturation parameter C′. This kind of saturation test image has various applications, such as in the checking of color masking effect in visual experiments and the testing of the visual effects of image similarity component.

  18. A STUDY OF LIFT-OFF TEST METHOD OF GROUND ANCHORS

    Science.gov (United States)

    Fujiwara, Yuu; Sakai, Toshinori

    Ground anchors (hereinafter anchors) are important to do the maintenance after construction. Residual tensile strength of anchors are generally confirmed by lift-off test that pulls an anchor using a hydraulic jack. However, the lift-off test has not been established a proper testing method. Therefore, it may not have been proper maintenance from measurement variability. In this paper, we conducted various lift-off test at cut slope of the expressway, and made proposals on proper lift-off test method.

  19. Preliminary Tests For Development Of A Non-Pertechnetate Analysis Method

    Energy Technology Data Exchange (ETDEWEB)

    Diprete, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-28

    The objective of this task was to develop a non-pertechnetate analysis method that 222-S lab could easily implement. The initial scope involved working with 222-S laboratory personnel to adapt the existing Tc analytical method to fractionate the non-pertechnetate and pertechnetate. SRNL then developed and tested a method using commercial sorbents containing Aliquat® 336 to extract the pertechnetate (thereby separating it from non-pertechnetate), followed by oxidation, extraction, and stripping steps, and finally analysis by beta counting and Mass Spectroscopy. Several additional items were partially investigated, including impacts of a 137Cs removal step. The method was initially tested on SRS tank waste samples to determine its viability. Although SRS tank waste does not contain non-pertechnetate, testing with it was useful to investigate the compatibility, separation efficiency, interference removal efficacy, and method sensitivity.

  20. A new method for testing and evaluating grassy airfields and its effects upon flying safety

    OpenAIRE

    Jarosław PYTKA; Jan LASKOWSKI; Piotr TARKOWSKI

    2017-01-01

    The paper contains a review of methods and technologies developed during a research project entitled “Methods of testing and evaluation of grassy airfields”, conducted at the Lublin University of Technology between 2011 and 2014. Based on the terramechanical studies of wheel-soil interactions, the authors have developed a method for the determination of wheel-grass friction and rolling resistance coefficients, which are of critical importance for the ground performance of an airplane. Moreove...

  1. Evaluation of semisolid agar method for antifungal susceptibility test of T. rubrum

    Directory of Open Access Journals (Sweden)

    Sultana Razia

    2016-08-01

    Full Text Available Background: With increasing fungal disease many newer antifungal drugs are available with different spectrum of activ­ity. Antifungal susceptibility test will help clinicians for selection of effective drug and thereby treatment of patient. Objective: The study was undertaken to perform a simple screening drug susceptibility test of T. rnbrum by Semi Solid Agar Antifungal Susceptibility (SAAS Method: Perfonnance of susceptibility method was assessed by comparing the MICs of three commonly prescribed antifungal agents namely- tluconazole (FCZ, itraconazole (ITZ and terbinafine (TER to the CLSI (Clinical and Laboratory Standard Institute recommended M-38, a broth microdilution method. Results: In SAAS method, among twenty nine T. rubrum, twenty five (86.2% were susceptible (MIC range 0.5-64 µg/ml to Fluconazole (FCZ and four (13.7% were resistant (MIC value >64 µg/ml. In broth microdilution method, among twenty nine T. rubrum, twenty six (89.6% were susceptible (MIC range 0.3-64 µg/ml to FCZ and three (10.3% were resistant (MIC value >64 µg/ml. In case of both ITZ and TER, all were susceptible (MIC range 0.3-64 µg/ml to both methods. The SAAS method demonstrated the susceptibility pattern of T. rubrum against FCZ, ITZ and TER usually within 72 to 96 hours after organism isolation and results were concordance with the results of CLSI broth microdilution method. Conclusion: Though it is a newer method with proper standardization of the test method, SAAS method is simple and easily applicable screening method for susceptibility testing of antifungal agents against dermatophytes in any microbiology laboratories.

  2. Testing Faith: A Mixed Methods Study Investigating the Relationship between Prayer and Test Anxiety amongst College Students

    Science.gov (United States)

    Campbell, Drey

    2016-01-01

    Test anxiety is problem that affects college students. Explanatory mixed methods research was completed with the objective of understanding the interrelationship of prayer and test anxiety as well as the potential therapeutic effects of Christian prayer on test anxiety. It was hypothesized that Christian prayer would have significant effects on…

  3. Local tolerance testing under REACH: Accepted non-animal methods are not on equal footing with animal tests.

    Science.gov (United States)

    Sauer, Ursula G; Hill, Erin H; Curren, Rodger D; Raabe, Hans A; Kolle, Susanne N; Teubner, Wera; Mehling, Annette; Landsiedel, Robert

    2016-07-01

    In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required. 2016 FRAME.

  4. Extreme Wind Calculation Applying Spectral Correction MethodTest and Validation

    DEFF Research Database (Denmark)

    Rathmann, Ole Steen; Hansen, Brian Ohrbeck; Larsén, Xiaoli Guo

    2016-01-01

    We present a test and validation of extreme wind calculation applying the Spectral Correction (SC) method as implemented in a DTU Wind Condition Software. This method can do with a short-term(~1 year) local measured wind data series in combination with a long-term (10-20 years) reference modelled...... wind data series like CFSR and CFDDA reanalysis data for the site in question. The validation of the accuracy was performed by comparing with estimates by the traditional Annual Maxim a (AM) method and the Peak Over Threshold (POT) method, applied to measurements, for six sites: four sites located...... in Denmark, one site located in the Netherlands and one site located in the USA, comprising both on-shore and off-shore sites. The SC method was applied to 1-year measured wind data while the AM and POT methods were applied to long-term measured wind data. Further, the consistency of the SC method...

  5. Analysis of small sample size studies using nonparametric bootstrap test with pooled resampling method.

    Science.gov (United States)

    Dwivedi, Alok Kumar; Mallawaarachchi, Indika; Alvarado, Luis A

    2017-06-30

    Experimental studies in biomedical research frequently pose analytical problems related to small sample size. In such studies, there are conflicting findings regarding the choice of parametric and nonparametric analysis, especially with non-normal data. In such instances, some methodologists questioned the validity of parametric tests and suggested nonparametric tests. In contrast, other methodologists found nonparametric tests to be too conservative and less powerful and thus preferred using parametric tests. Some researchers have recommended using a bootstrap test; however, this method also has small sample size limitation. We used a pooled method in nonparametric bootstrap test that may overcome the problem related with small samples in hypothesis testing. The present study compared nonparametric bootstrap test with pooled resampling method corresponding to parametric, nonparametric, and permutation tests through extensive simulations under various conditions and using real data examples. The nonparametric pooled bootstrap t-test provided equal or greater power for comparing two means as compared with unpaired t-test, Welch t-test, Wilcoxon rank sum test, and permutation test while maintaining type I error probability for any conditions except for Cauchy and extreme variable lognormal distributions. In such cases, we suggest using an exact Wilcoxon rank sum test. Nonparametric bootstrap paired t-test also provided better performance than other alternatives. Nonparametric bootstrap test provided benefit over exact Kruskal-Wallis test. We suggest using nonparametric bootstrap test with pooled resampling method for comparing paired or unpaired means and for validating the one way analysis of variance test results for non-normal data in small sample size studies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    Science.gov (United States)

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The accuracy of groundwater-level tapes was investigated by developing a tape calibration method and device and testing the accuracy of a sample of groundwater-level tapes with the calibration method and device. The sample of tapes included in-service U.S. Geological Survey (USGS) Water Science Center steel and electric groundwater-level tapes.

  7. The Impact of Test Dimensionality, Common-Item Set Format, and Scale Linking Methods on Mixed-Format Test Equating

    Science.gov (United States)

    Öztürk-Gübes, Nese; Kelecioglu, Hülya

    2016-01-01

    The purpose of this study was to examine the impact of dimensionality, common-item set format, and different scale linking methods on preserving equity property with mixed-format test equating. Item response theory (IRT) true-score equating (TSE) and IRT observed-score equating (OSE) methods were used under common-item nonequivalent groups design.…

  8. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Science.gov (United States)

    2010-07-01

    ... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... candidate test sampler shall have its inlet and impactor or impactors removed. The lower end of the down... aerosol is introduced at the top of the downtube. (f) Test procedure. (1) All surfaces of the added or...

  9. Adapting Tests for Use in Different Cultures: Technical Issues and Methods.

    Science.gov (United States)

    Hambleton, Ronald K.; Bollwark, John

    The validity of results from international assessments depends on the correctness of the test translations. If the tests presented in one language are more or less difficult because of the manner in which they are translated, the validity of any interpretation of the results can be questioned. Many test translation methods exist in the literature,…

  10. 40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?

    Science.gov (United States)

    2010-07-01

    ... requirements of this section may involve the use of hazardous materials, operations and equipment. This section...) What process must a test facility follow in order to qualify a test method for determining the fuel... control charts from the mandatory quality control testing prescribed in paragraph 7.1 of the reference...

  11. Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

    Science.gov (United States)

    Juarez, Alfredo; Harper, Susana Tapia

    2016-01-01

    The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

  12. Creating IRT-Based Parallel Test Forms Using the Genetic Algorithm Method

    Science.gov (United States)

    Sun, Koun-Tem; Chen, Yu-Jen; Tsai, Shu-Yen; Cheng, Chien-Fen

    2008-01-01

    In educational measurement, the construction of parallel test forms is often a combinatorial optimization problem that involves the time-consuming selection of items to construct tests having approximately the same test information functions (TIFs) and constraints. This article proposes a novel method, genetic algorithm (GA), to construct parallel…

  13. 46 CFR 160.010-7 - Methods of sampling, inspections and tests.

    Science.gov (United States)

    2010-10-01

    ... manufacturer— (1) Uses the same plastic buoyancy foam used in previous production lots, (2) Determines that the... plastic buoyancy foam controls permitted as an alternative to the buoyancy test in paragraph (e) of this... Vessels § 160.010-7 Methods of sampling, inspections and tests. (a) General. Production tests must be...

  14. A test of the Lake Habitat Survey method in Cleveland Reservoir ...

    African Journals Online (AJOL)

    The Lake Habitat Survey (LHS) method has only been applied once in a tropical African reservoir and could potentially be a useful tool for hydromorphological impact assessments. This study (October 2012) tested the application of the LHS method to two Zimbabwean reservoirs, Cleveland and Chivero, which are impacted ...

  15. 76 FR 50221 - International Workshop on Alternative Methods for Human and Veterinary Rabies Vaccine Testing...

    Science.gov (United States)

    2011-08-12

    ... HUMAN SERVICES International Workshop on Alternative Methods for Human and Veterinary Rabies Vaccine... ``International Workshop on Alternative Methods for Human and Veterinary Rabies Vaccine Testing: State of the... approaches that may reduce, refine, or replace animal use in human and veterinary rabies vaccine potency...

  16. Screening of Plant Extracts for Antioxidant Activity: a Comparative Study on Three Testing Methods

    NARCIS (Netherlands)

    Koleva, I.; Beek, van T.A.; Linssen, J.P.H.; Groot, de Æ.; Evstatieva, L.N.

    2002-01-01

    Three methods widely employed in the evaluation of antioxidant activity, namely 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging method, static headspace gas chromatography (HS-GC) and -carotene bleaching test (BCBT), have been compared with regard to their application in the screening of

  17. X-ray scatter correction method for dedicated breast computed tomography: improvements and initial patient testing

    NARCIS (Netherlands)

    Ramamurthy, S.; D'Orsi, C.J.; Sechopoulos, I.

    2016-01-01

    A previously proposed x-ray scatter correction method for dedicated breast computed tomography was further developed and implemented so as to allow for initial patient testing. The method involves the acquisition of a complete second set of breast CT projections covering 360 degrees with a

  18. Standard test method for translaminar fracture toughness of laminated and pultruded polymer matrix composite materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers the determination of translaminar fracture toughness, KTL, for laminated and pultruded polymer matrix composite materials of various ply orientations using test results from monotonically loaded notched specimens. 1.2 This test method is applicable to room temperature laboratory air environments. 1.3 Composite materials that can be tested by this test method are not limited by thickness or by type of polymer matrix or fiber, provided that the specimen sizes and the test results meet the requirements of this test method. This test method was developed primarily from test results of various carbon fiber – epoxy matrix laminates and from additional results of glass fiber – epoxy matrix, glass fiber-polyester matrix pultrusions and carbon fiber – bismaleimide matrix laminates (1-4, 6, 7). 1.4 A range of eccentrically loaded, single-edge-notch tension, ESE(T), specimen sizes with proportional planar dimensions is provided, but planar size may be variable and adjusted, with asso...

  19. Reveal Salmonella 2.0 test for detection of Salmonella spp. in foods and environmental samples. Performance Tested Method 960801.

    Science.gov (United States)

    Hoerner, Rebecca; Feldpausch, Jill; Gray, R Lucas; Curry, Stephanie; Islam, Zahidul; Goldy, Tim; Klein, Frank; Tadese, Theodros; Rice, Jennifer; Mozola, Mark

    2011-01-01

    Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non

  20. The Development of Testing Methods for Characterizing Emissions and Sources of Exposures from Polyurethane Products

    Science.gov (United States)

    The relationship between onsite manufacture of spray polyurethane foam insulation (SPFI) and potential exposures is not well understood. Currently, no comprehensive standard test methods exist for characterizing and quantifying product emissions. Exposures to diisocyanate compoun...

  1. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standard test method for linear-elastic plane-strain fracture toughness KIc of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2013-01-01

    1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials under predominantly linear-elastic, plane-strain conditions using fatigue precracked specimens having a thickness of 1.6 mm (0.063 in.) or greater subjected to slowly, or in special (elective) cases rapidly, increasing crack-displacement force. Details of test apparatus, specimen configuration, and experimental procedure are given in the Annexes. Note 1—Plane-strain fracture toughness tests of thinner materials that are sufficiently brittle (see 7.1) can be made using other types of specimens (1). There is no standard test method for such thin materials. 1.2 This test method is divided into two parts. The first part gives general recommendations and requirements for KIc testing. The second part consists of Annexes that give specific information on displacement gage and loading fixture design, special requirements for individual specimen configurations, and detailed procedures for fatigue precracking. Additional a...

  3. Standard test method for linear-elastic plane-strain fracture toughness KIc of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials under predominantly linear-elastic, plane-strain conditions using fatigue precracked specimens having a thickness of 1.6 mm (0.063 in.) or greater subjected to slowly, or in special (elective) cases rapidly, increasing crack-displacement force. Details of test apparatus, specimen configuration, and experimental procedure are given in the Annexes. Note 1—Plane-strain fracture toughness tests of thinner materials that are sufficiently brittle (see 7.1) can be made using other types of specimens (1). There is no standard test method for such thin materials. 1.2 This test method is divided into two parts. The first part gives general recommendations and requirements for KIc testing. The second part consists of Annexes that give specific information on displacement gage and loading fixture design, special requirements for individual specimen configurations, and detailed procedures for fatigue precracking. Additional a...

  4. Developmental Potential of Professional Test as a Method of Training Future Teachers

    Directory of Open Access Journals (Sweden)

    Neumoeva-Kolchedantseva E.V.

    2018-01-01

    Full Text Available The article is devoted to studying the developmental perspectives of the method of professional test. It offers an understanding of the professional test as a method of «locally immersing» students in professional activities at the stage of university training. It also describes an experience of evaluating professional tests aimed at mastering work actions defined in the professional standard for teachers. The article examines research data on the impact of the professional test on the development of professional competencies (work actions in future teachers. The research involved 50 third- and fourth-year students of the Tyumen State University majoring in «Teacher Education» («Primary School Education».The results confirm the positive dynamics of work actions after the completion of professional tests, which points to the developmental potential of the professional test as a method of training future teachers.

  5. Screening methods for assessment of biodegradability of chemicals in seawater--results from a ring test

    Energy Technology Data Exchange (ETDEWEB)

    Nyholm, N.; Kristensen, P. (Water Quality Institute, Horsholm, (Denmark))

    1992-04-01

    An international ring test involving 14 laboratories was organized on behalf of the Commission of the European Economic Communities (EEC) with the purpose of evaluating two proposed screening methods for assessment of biodegradability in seawater: (a) a shake flask die-away test based primarily on analysis of dissolved organic carbon and (b) a closed bottle test based on determination of dissolved oxygen. Both tests are performed with nutrient-enriched natural seawater as the test medium and with no inoculum added other than the natural seawater microflora. The test methods are seawater versions of the modified OECD screening test and the closed bottle test, respectively, adopted by the Organization for Economic Cooperation and Development (OECD) and by the EEC as tests for ready biodegradability.' The following five chemicals were examined: sodium benzoate, aniline, diethylene glycol, pentaerythritol, and 4-nitrophenol. Sodium benzoate and aniline, which are known to be generally readily biodegradable consistently degraded in practically all tests, thus demonstrating the technical feasibility of the methods. Like in previous ring tests with freshwater screening methods variable results were obtained with the other three compounds, which is believed primarily to be due to site-specific differences between the microflora of the different seawater samples used and to some extent also to differences in the applied concentrations of test material. A positive result with the screening methods indicates that the test substance will most likely degrade relatively rapidly in seawater from the site of collection, while a negative test result does not preclude biodegradability under environmental conditions where the concentrations of chemicals are much lower than the concentrations applied for analytical reasons in screening tests.

  6. expansion method

    Indian Academy of Sciences (India)

    In this paper, we shall apply the (G /G)-expansion method to obtain the exact travelling wave solution of the two-dimensional ... In §3, we apply our method to the mentioned equations. In §4, some conclusions are ..... The exact solution obtained by this method can be used to check computer codes or as initial condition for ...

  7. Test methods for evaluating the filtration and particulate emission characteristics of vacuum cleaners.

    Science.gov (United States)

    Willeke, K; Trakumas, S; Grinshpun, S A; Reponen, T; Trunov, M; Friedman, W

    2001-01-01

    The overall filtration efficiency of a vacuum cleaner traditionally has been tested by placing the vacuum cleaner in a test chamber and measuring aerosol concentrations at the chamber inlet and outlet. The chamber test method was refined and validated in this study. However, this chamber test method shows an overall filtration efficiency of close to 100% for most of the industrial vacuum cleaners and for most of the newly developed household vacuum cleaners of midprice range or higher because all these vacuum cleaners have a high-efficiency particulate air (HEPA) or other highly efficient filter installed at the exhaust. A new test method was therefore developed through which the vacuum cleaner was probed in various internal locations so that the collection efficiency of the individual components could be determined. For example, the aerosol concentration upstream of the final HEPA filter can thus be measured, which permits one to estimate the life expectancy of this expensive component. The probed testing method is particularly suitable for field evaluations of vacuum cleaners because it uses compact, battery-operated optical particle size spectrometers with internal data storage. Both chamber and probed tests gave the same results for the aerosol filtration efficiency. The probed testing method, however, also gives information on the performance of the individual components in a vacuum cleaner. It also can be used to determine the dust pickup efficiency and the degree of reaerosolization of particles collected in the vacuum cleaner.

  8. A new compound control method for sine-on-random mixed vibration test

    Science.gov (United States)

    Zhang, Buyun; Wang, Ruochen; Zeng, Falin

    2017-09-01

    Vibration environmental test (VET) is one of the important and effective methods to provide supports for the strength design, reliability and durability test of mechanical products. A new separation control strategy was proposed to apply in multiple-input multiple-output (MIMO) sine on random (SOR) mixed mode vibration test, which is the advanced and intensive test type of VET. As the key problem of the strategy, correlation integral method was applied to separate the mixed signals which included random and sinusoidal components. The feedback control formula of MIMO linear random vibration system was systematically deduced in frequency domain, and Jacobi control algorithm was proposed in view of the elements, such as self-spectrum, coherence, and phase of power spectral density (PSD) matrix. Based on the excessive correction of excitation in sine vibration test, compression factor was introduced to reduce the excitation correction, avoiding the destruction to vibration table or other devices. The two methods were synthesized to be applied in MIMO SOR vibration test system. In the final, verification test system with the vibration of a cantilever beam as the control object was established to verify the reliability and effectiveness of the methods proposed in the paper. The test results show that the exceeding values can be controlled in the tolerance range of references accurately, and the method can supply theory and application supports for mechanical engineering.

  9. [A novel method for testing sterility of injections based on biothermodynamics].

    Science.gov (United States)

    Gao, Dan; Gao, Dan; Ren, Yong-Shen; Yan, Dan; Zhang, Cong-En; Yan, Zhu-Yun; Xiong, Yin; Ma, Li-Na; Zhang, Le-Le; Xiao, Xiao-He

    2014-03-01

    This study aims at trying to establish a novel method of sterility test for injections based on biothermodynamics, in order to overcome the deficiencies of routine sterility tests such as long detecting cycle, low sensitivity and prone to misjudgments. A biothermodynamics method was adopted to rapidly detect the microorganism contamination of injections by monitoring the heat metabolism during the growth of microbe. The growth rate equal to or greater than zero and the heat power difference of P(i) and P(0) with three folds higher than the noise of baseline were chosen as indexes to study the heat change rule of microbe. In this way, the effectiveness of the new method to detect strains required by conventional sterility test or in injection samples was also investigated. Results showed that the Gram-positive bacteria, Gram-negative bacteria and fungi demanded by sterility testing methodology could be detected by biothermodynamics method within 10 hours, with the sensitivity lower than 100 CFU x mL(-1). Meanwhile, this method was successfully applied to the sterility test of Compound Yinchen injection (FFYC), Shuanghuanglian powder injection (SHL) and Compound Triamcinolone injection (TAND) which were sterilized with different degrees. Therefore, the biothermodynamics method, with advantages of fast detection and high sensitivity, could be a complementary solution for conventional sterility tests.

  10. Standard Test Method for Mechanical Hydrogen Embrittlement Evaluation of Plating/Coating Processes and Service Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method describes mechanical test methods and defines acceptance criteria for coating and plating processes that can cause hydrogen embrittlement in steels. Subsequent exposure to chemicals encountered in service environments, such as fluids, cleaning treatments or maintenance chemicals that come in contact with the plated/coated or bare surface of the steel, can also be evaluated. 1.2 This test method is not intended to measure the relative susceptibility of different steels. The relative susceptibility of different materials to hydrogen embrittlement may be determined in accordance with Test Method F1459 and Test Method F1624. 1.3 This test method specifies the use of air melted AISI E4340 steel per SAE AMS-S-5000 (formerly MIL-S-5000) heat treated to 260 – 280 ksi (pounds per square inch x 1000) as the baseline. This combination of alloy and heat treat level has been used for many years and a large database has been accumulated in the aerospace industry on its specific response to exposure...

  11. A proposed method for design of test cases for economic analysis in power systems

    Directory of Open Access Journals (Sweden)

    J.A. Marmolejo-Saucedo

    2015-06-01

    Full Text Available Nowadays, in power systems, we still lack the existence of standardized test systems that can be used to benchmark the performance and solution quality of proposed optimization techniques. Several authors report that the electric load pattern is very complex. It is therefore necessary to develop new methods for design of test cases for economic analysis in power systems. Therefore, we compared two methods to generate test systems: time series model and a method simulating stable random variables based on the use of Chambers, Mallows, & Stuck (1976. This paper describes a method for simulating stable random variables in the generation of test systems for economic analysis in power systems. A study focused on generating test electrical systems through stable distribution to model for unit commitment problem in electrical power systems. Usually, the instances of test systems in unit commitment are generated using normal distribution, but the behavior of electrical demand does not follow a normal distribution; in this work, simulation data are based on a new method. For empirical analysis, we used three original systems to obtain the demand behavior and thermal production costs. Numerical results illustrate the applicability of the proposed method by solving several unit commitment problems directly and through the Lagrangian relaxation of the original problem.

  12. HER2 testing in the UK: recommendations for breast and gastric in-situ hybridisation methods

    LENUS (Irish Health Repository)

    Bartlett, J. M. S.

    2011-01-01

    These guidelines supplement existing guidelines on HER2 testing by immunohistochemistry and in-situ hybridisation(ISH) methods in the UK. They provide a specific focus on aspects of guidance relevant to HER2 ISH testing methods, both fluorescent and chromogenic. They are formulated to give advice on methodology, interpretation and quality control for ISH-based testing of HER2 status in common tumour types, including both breast and gastric tumours. The aim is to ensure that all ISH-based testing is accurate, reliable and timely.

  13. Assessment of test methods evaluating mucoadhesive polymers and dosage forms: an overview.

    Science.gov (United States)

    Woertz, Christina; Preis, Maren; Breitkreutz, Jörg; Kleinebudde, Peter

    2013-11-01

    Oral mucoadhesive preparations have gained increasing importance in the last decades, by reason of numerous advantages like easy application, discrete handling and no swallowing of the drug product. Pharmacopoeial methods to study mucoadhesion are not available so far, despite the new monograph for oromucosal preparations is valid since the European Pharmacopoeia 7.4 (2012) including a chapter on mucoadhesive preparations. Several mucoadhesion test methods are reviewed concerning the applicability for various polymers, different drug dosage forms and comparability of experimental set-ups. Different test methods and experimental set-ups lead to huge differences regarding the results. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Modal testing with Asher's method using a Fourier analyzer and curve fitting

    Science.gov (United States)

    Gold, R. R.; Hallauer, W. L., Jr.

    1979-01-01

    An unusual application of the method proposed by Asher (1958) for structural dynamic and modal testing is discussed. Asher's method has the capability, using the admittance matrix and multiple-shaker sinusoidal excitation, of separating structural modes having indefinitely close natural frequencies. The present application uses Asher's method in conjunction with a modern Fourier analyzer system but eliminates the necessity of exciting the test structure simultaneously with several shakers. Evaluation of this approach with numerically simulated data demonstrated its effectiveness; the parameters of two modes having almost identical natural frequencies were accurately identified. Laboratory evaluation of this approach was inconclusive because of poor experimental input data.

  15. Method and system for an on-chip AC self-test controller

    Energy Technology Data Exchange (ETDEWEB)

    Flanagan, John D [Rhinebeck, NY; Herring, Jay R [Poughkeepsie, NY; Lo, Tin-Chee [Fishkill, NY

    2008-09-30

    A method and system for performing AC self-test on an integrated circuit that includes a system clock for use during normal operation are provided. The method includes applying a long data capture pulse to a first test register in response to the system clock, applying an at speed data launch pulse to the first test register in response to the system clock, inputting the data from the first register to a logic path in response to applying the at speed data launch pulse to the first test register, applying an at speed data capture pulse to a second test register in response to the system clock, inputting the logic path output to the second test register in response to applying the at speed data capture pulse to the second test register, and applying a long data launch pulse to the second test register in response to the system clock.

  16. Nozzle Initiative Industry Advisory Committee on Standardization of Carbon-Phenolic Test Methods and Specifications

    Science.gov (United States)

    Bull, William B.; Pinoli, Pat C.; Upton, Cindy G.; Day, Tony; Hill, Keith; Stone, Frank; Hall, William B.

    1994-12-01

    This report is a compendium of the presentations of the 12th biannual meeting of the Industry Advisory Committee under the Solid Propulsion Integrity Program. A complete transcript of the welcoming talks is provided. Presentation outlines and overheads are included for the other sessions: SPIP Overview, Past, Current and Future Activity; Test Methods Manual and Video Tape Library; Air Force Developed Computer Aided Cure Program and SPC/TQM Experience; Magneto-Optical mapper (MOM), Joint Army/NASA program to assess composite integrity; Permeability Testing; Moisture Effusion Testing by Karl Fischer Analysis; Statistical Analysis of Acceptance Test Data; NMR Phenolic Resin Advancement; Constituent Testing Highlights on the LDC Optimization Program; Carbon Sulfur Study, Performance Related Testing; Current Rayon Specifications and Future Availability; RSRM/SPC Implementation; SRM Test Methods, Delta/Titan/FBM/RSRM; and Open Forum on Performance Based Acceptance Testing -- Industry Experience.

  17. Control Method for Electromagnetic Unmanned Robot Applied to Automotive Test Based on Improved Smith Predictor Compensator

    Directory of Open Access Journals (Sweden)

    Gang Chen

    2015-07-01

    Full Text Available A new control method for an electromagnetic unmanned robot applied to automotive testing (URAT and based on improved Smith predictor compensator, and considering a time delay, is proposed. The mechanical system structure and the control system structure are presented. The electromagnetic URAT adopts pulse width modulation (PWM control, while the displacement and the current doubles as a closed-loop control strategy. The coordinated control method of multiple manipulators for the electromagnetic URAT, e.g., a skilled human driver with intelligent decision-making ability is provided, and the improved Smith predictor compensator controller for the electromagnetic URAT considering a time delay is designed. Experiments are conducted using a Ford FOCUS automobile. Comparisons between the PID control method and the proposed method are conducted. Experimental results show that the proposed method can achieve the accurate tracking of the target vehicle's speed and reduce the mileage derivation of autonomous driving, which meets the requirements of national test standards.

  18. Differences in vancomycin MIC among MRSA isolates by agar dilution and E test method

    Directory of Open Access Journals (Sweden)

    K Tandel

    2012-01-01

    Full Text Available In this study, the correlation between vancomycin minimum inhibitory concentration (MIC obtained by the E test technique and the Clinical And Laboratory Standards Institute (CLSI agar dilution method was evaluated. A total of 53 Methicillin Resistant Staphylococcus aureus (MRSA strains were tested by both the methods in the present study. MICs of vancomycin obtained by the E test method were consistently higher (+0.5 to 2 log2 dilutions than those obtained by the agar dilution method. Out of 53 MRSA isolates, 49 isolates showed higher MIC results by E test than by agar dilution method. Three isolates showed same MIC result by both methods. Since many studies have demonstrated increased clinical failure with MRSA isolates for which vancomycin MICs are increased (>1 μg/ml but still within the susceptibility range (≤ 2 μg/ml, our findings suggest the requirement to re-look into the breakpoints for vancomycin for determining sensitivity of MRSA isolates. Guidelines should also specify the method to be used for determining the MIC.

  19. Comparative Study of Impedance Eduction Methods. Part 1; DLR Tests and Methodology

    Science.gov (United States)

    Busse-Gerstengarbe, Stefan; Bake, Friedrich; Enghardt, Lars; Jones, Michael G.

    2013-01-01

    The absorption efficiency of acoustic liners used in aircraft engines is characterized by the acoustic impedance. World wide, many grazing ow test rigs and eduction methods are available that provide values for that impedance. However, a direct comparison and assessment of the data of the di erent rigs and methods is often not possible because test objects and test conditions are quite di erent. Only a few papers provide a direct comparison. Therefore, this paper together with a companion paper, present data measured with a reference test object under similar conditions in the DLR and NASA grazing ow test rigs. Additionally, by applying the in-house methods Liner Impedance Non-Uniform ow Solving algorithm (LINUS, DLR) and Convected Helmhholtz Equation approach (CHE, NASA) on the data sets, similarities and differences due to underlying theory are identi ed and discussed.

  20. Application Study of Self-balanced Testing Method on Big Diameter Rock-socketed Piles

    Directory of Open Access Journals (Sweden)

    Qing-biao WANG

    2013-07-01

    Full Text Available Through the technological test of self-balanced testing method on big diameter rock-socketed piles of broadcasting centre building of Tai’an, this paper studies and analyzes the links of the balance position selection, the load cell production and installation, displacement sensor selection and installation, loading steps, stability conditions and determination of the bearing capacity in the process of self-balanced testing. And this paper summarizes key technology and engineering experience of self-balanced testing method of big diameter rock-socketed piles and, meanwhile, it also analyzes the difficult technical problems needed to be resolved urgently at present. Conclusion of the study has important significance to the popularization and application of self-balanced testing method and the similar projects.

  1. Evaluation of MIMIC-Model Methods for DIF Testing With Comparison to Two-Group Analysis.

    Science.gov (United States)

    Woods, Carol M

    2009-01-01

    Differential item functioning (DIF) occurs when an item on a test or questionnaire has different measurement properties for 1 group of people versus another, irrespective of mean differences on the construct. This study focuses on the use of multiple-indicator multiple-cause (MIMIC) structural equation models for DIF testing, parameterized as item response models. The accuracy of these methods, and the sample size requirements, are not well established. This study examines the accuracy of MIMIC methods for DIF testing when the focal group is small and compares results with those obtained using 2-group item response theory (IRT). Results support the utility of the MIMIC approach. With small focal-group samples, tests of uniform DIF with binary or 5-category ordinal responses were more accurate with MIMIC models than 2-group IRT. Recommendations are offered for the application of MIMIC methods for DIF testing.

  2. Development of convective testing methods for low-rise multifamily buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Stiles, M.R. [Synertech Systems Corp., Syracuse, NY (United States)

    1996-08-01

    This report describes convective testing methods and protocols developed for use in weatherizing low-rise multifamily buildings. The methods can lead to controlling internal air movement and preventing leakage to the exterior by estimating magnitudes of air leakage pathways in garden and town house apartments. The 4 methods cited are: After-a-Retrofit; Equivalent Interfaces; Open-a-Door; and Add-a-Pathway. It is found that, because of modern interior finishing practices, convective problems tend to be more associated with indoor air quality than loss of space conditioning energy. The After-a-Retrofit method is the easiest to integrate into current diagnostic practices. In some cases, the Equivalent Interfaces method may be used on a production basis. The methods are an advance on current field practices that do not quantify the leakage pathways and research practices that require extensive equipment.

  3. Permanent deformation testing for a new South African mechanistic pavement design method

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2012-01-01

    Full Text Available African Pavement Design Method (SAPDM) will use permanent deformation in addition to fatigue characteristics to model damage of HMA materials [5]. Permanent deformation properties determined from repeated load uniaxial or triaxial tests are key... temperature and stress pair require a news specimen to be used, because permanent deformation test is destructive, and samples are usually assumed to be damaged after testing; ? Conduct test to collect permanent strain accumulation data up to 20,000 load...

  4. Validation of a test method for the measurement of methanol emissions from stationary sources.

    Science.gov (United States)

    Peterson, M R; Pate, B A; Rickman, E E; Jayanty, R K; Wilshire, F W; Knoll, J E

    1995-01-01

    Title III of the 1990 Clean Air Act Amendments designated methanol as a pollutant to be regulated. The U.S. Environmental Protection Agency (EPA), through a contract with Research Triangle Institute, has developed a method for measuring methanol emissions from stationary sources. The methanol sampling train (MST) consists of a glass-lined heated probe, two condensate knockout traps, and three sorbent cartridges packed with Anasorb 747. Samples are desorbed with a 1:1 mixture of carbon disulfide (CS2) and N,N-dimethylformamide (DMF). Condensate water and CS2/ DMF samples are analyzed by gas chromatography with flame ionization detection. The MST has a practical quantitation limit of approximately 3 ppm for a 20-L sample. Samples were shown to be stable for at least two weeks after collection. Field tests of the MST and the National Council of the Paper Industry for Air and Stream Improvement (NCASI) methanol sampling method were conducted at two pulp and paper mills. Sampling and analysis procedures followed EPA Method 301 requirements. The sampling location for the first field test was the inlet vent to a softwood bleach plant scrubber, where the methanol concentration was approximately 30 ppm. The mean recovery of spike was 108.3% for the MST method and 81.6% for the NCASI method. Although neither method showed significant bias at the 95% confidence level, the between-methods bias was significantly different. A second field test was conducted at a vent from a black liquor oxidation tank where the methanol concentration was approximately 350 ppm. Mean spike recoveries were 96.6 and 94.2% for the MST and NCASI methods, respectively. The biases of the two methods and the between-methods bias were not significantly different for the second field test.

  5. [Clinical and experimental studies on gastrointestinal motility following total colectomy: direct measurement (strain gauge force transducer method, barium method) and indirect measurement (hydrogen breath test, acetaminophen method)].

    Science.gov (United States)

    Kayama, H; Koh, K

    1991-04-01

    In a clinical study, we examined the clinical assessment of bowel function and lactulose hydrogen breath test in 14 patients after total colectomy. All patients within one year after ileostomy closure had 'poor' function and showed no increase of hydrogen breath gas concentration. 10 of 12 patients more than one year showed increase of hydrogen breath gas concentration, and 8 of them had 'fair' function. The oro-neorectal transit time (ONTT) in 'poor' group was shorter than in 'fair' group and control (p less than 0.05). The increase of hydrogen breath gas suggests changes of bacterial flora and colonization of the remained ileum. In an experimental study, we performed subtotal colectomy with the J-pouch reservoir in 11 dogs. We examined ONTT with barium method, gastric emptying with acetaminophen method, and gastrointestinal motility with strain gauge force transducers. Although ONTT at one month after operation had been shorter than control, ONTT at 3 and 6 months became longer than at one month. The gastric emptying after subtotal colectomy was significantly slower than control. Although the propagation velocity of interdigestive migrating complex (IMC) in the jejunum and ileum at 2 weeks had been faster than control, the velocity at 4 weeks and 3 months became slower than at 2 weeks. The frequency of IMC and prolonged propagated contraction in the J-pouch reservoir decreased. The specimen of J-pouch reservoir resected at 6 months showed villous atrophy, crypt elongation, decrease of muscle layers thickness and disappearance of solitary follicles. Therefore, the suppressed motility in each sites of the gastrointestinal tract, increase of anaerobic and colonization of the ileum implied 'adaptation' after total colectomy.

  6. COMPARISON OF SHEAR STRENGTH OF CERAMIC JOINTS DETERMINED BY VARIOUS TEST METHODS WITH SMALL SPECIMENS

    Energy Technology Data Exchange (ETDEWEB)

    Katoh, Yutai [ORNL; Kiggans Jr, James O [ORNL; Khalifa, Hesham [General Atomics, San Diego; Back, Christina A. [General Atomics, San Diego; Hinoki, Tatsuya [Kyoto University, Japan; Ferraris, Monica [Politecnico di Torino

    2015-01-01

    Four different shear test methods i.e. doubled notched shear test, asymmetrical four point bend test, Iosipescu test, and torsion test, were investigated for their ability to evaluate one standard SiC to SiC ceramic brittle joint while using small size specimens. Double notched shear test showed higher stress concentration at the notch base and a lower nominal shear strength. Both asymmetrical four point bend test and Iosipescu test utilized epoxy jointed metal extensors, which failed during test and caused misalignment and tensile type of failure. Torsion test can deliver true shear loading. However, base material failure was observed for the torsion joint samples in this study. None of the tests can successfully induce true shear failure of the joint because the joint is stronger and tougher than the SiC substrate. Torsion test appears to be promising because of the pure shear loading, less stress concentration, and easy alignment.

  7. Research of test fault diagnosis method for micro-satellite PSS

    Science.gov (United States)

    Wu, Haichao; Wang, Jinqi; Yang, Zhi; Yan, Meizhi

    2017-11-01

    Along with the increase in the number of micro-satellite and the shortening of the product's lifecycle, negative effects of satellite ground test failure become more and more serious. Real-time and efficient fault diagnosis becomes more and more necessary. PSS plays an important role in the satellite ground test's safety and reliability as one of the most important subsystems that guarantees the safety of micro-satellite energy. Take test fault diagnosis method of micro-satellite PSS as research object. On the basis of system features of PSS and classic fault diagnosis methods, propose a kind of fault diagnosis method based on the layered and loose coupling way. This article can provide certain reference for fault diagnosis methods research of other subsystems of micro-satellite.

  8. Standard test method for radiochemical determination of uranium isotopes in urine by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the determination of uranium in urine at levels of detection dependent on sample size, count time, detector background, and tracer yield. It is designed as a screening tool for detection of possible exposure of occupational workers. 1.2 This test method is designed for 50 mL of urine. This test method does not address the sampling protocol or sample preservation methods associated with its use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Proposed mixed-mode dynamic fracture toughness testing method using a new specimen

    Energy Technology Data Exchange (ETDEWEB)

    Wada, H.; Hinoshita, A. [Daido Institute of Technology, Nagoya (Japan); Calder, C.A.; Kennedy, T.C. [Oregon State Univ., Corvallis, OR (United States)

    1996-12-31

    To find a simple and highly accurate testing method for determining the mixed-mode dynamic fracture toughness in a wide range of ratio of opening and sliding modes, the authors applied a combination technique using an electrical resistance strain gage method and a dynamic finite element method (FEM) to determine the mixed-mode dynamic fracture toughness. They used measuring and recording devices associated with an impact fracture apparatus based on an air gun. The impact fracture test was conducted to assess the mixed-mode dynamic fracture toughness testing method under single-point bending for three specimens of polymethyl methacrylate (PMMA). The ratio of the opening mode deformation to the sliding mode can be changed by adjusting the hitting point. To measure a dynamic stress intensity factors (SIF) K{sub 1}(t) and a crack initiation time, a single axis strain gage was mounted in the vicinity of the crack tip.

  10. The ISRM suggested methods for rock characterization, testing and monitoring 2007-2014

    CERN Document Server

    2015-01-01

    This book is a collection of ISRM suggested methods for testing or measuring properties of rocks and rock masses both in the laboratory and in situ, as well as for monitoring the performance of rock engineering structures. The first collection (Yellow Book) has been published in 1981. In order to provide access to all the Suggested Methods in one volume, the ISRM Blue Book was published in 2007 (by the ISRM via the Turkish National Group) and contains the complete set of Suggested Methods from 1974 to 2006 inclusive. The papers in this most recent volume have been published during the last seven years in international journals, mainly in Rock Mechanics and Rock Engineering. They offer guidance for rock characterization procedures and laboratory and field testing and monitoring in rock engineering. These methods provide a definitive procedure for the identification, measurement and evaluation of one or more qualities, characteristics, or properties of rocks or rock systems that produces a test result.

  11. Suitability of the H2S method for testing untreated and chlorinated water supplies.

    Science.gov (United States)

    Nair, J; Gibbs, R; Mathew, K; Ho, G E

    2001-01-01

    Rainwater, borewater and catchment water are used for domestic water supply purposes with or without treatment in remote areas around the world. These places seldom have any facilities for routine testing of their drinking water. A simple on-site testing method is highly required in such areas. The H2S method has been tested for treated drinking water and was found to have a good correlation with the standard methods. The present study was aimed at assessing the suitability of the H2S method for testing different sources of drinking water. Since these types of water may contain H2S producing bacteria not of faecal origin the occurrence of false results in this method cannot be overruled. Therefore it was worthwhile to study whether the positive results are true positive results and what percentage of false positive and false negative results could be expected while using this test for routine analysis of water samples. Results were compared with the results using standard procedures for testing total coliforms, Escherichia coli and Salmonella spp. The present experiment analysed 121 rainwater samples, 17 borewater samples, 41 catchment water samples and 74 remote Aboriginal community water samples. Rainwater, borewater and catchment water samples gave true results of 78.5%, 82.3% and 80.5% respectively while the treated and untreated community samples gave true results of 93.7 and 84.6% respectively. It was concluded that in the developing countries where the acceptable level of total coliform is <10 MPN, the H2S method would be a good test to identify microbial contamination. In other regions, the H2S method could be used as a screening test for drinking water supplies.

  12. Review of different test methods for the evaluation of stability of biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Siddharth; Sharma, M.P. [Biofuel Research Laboratory, Alternate Hydro Energy Centre, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667 (India)

    2010-09-15

    The vegetable oil, fats and their biodiesel suffer with the drawback of deterioration of its quality when it is in contact with oxygen unlike petroleum diesel. There are various types of stabilities like oxidation, storage and thermal, playing key roles in making the fuel unstable. The present paper is an attempt to review all type of stability measuring test methods to find out the best method for stability measurement. From the review it is found that there are several methods to measure the stability of biodiesel but two test methods emerges the most likely choice for the purpose of measurement of oxidation stability of biodiesel. These are ASTM 2274 and 743 Rancimat test. A comparison between these two shows that these may be used alternatively. Most commonly used methods to investigate the thermal stability are Rancimat test, ASTM D 6408-08, D 5304-06 and TGA/DTA. Rancimat test has been suggested as an important method to measure the thermal stability of oils, fats and biodiesel fuels. (author)

  13. Diagnostic Methods of Helicobacter pylori Infection for Epidemiological Studies: Critical Importance of Indirect Test Validation

    Directory of Open Access Journals (Sweden)

    Muhammad Miftahussurur

    2016-01-01

    Full Text Available Among the methods developed to detect H. pylori infection, determining the gold standard remains debatable, especially for epidemiological studies. Due to the decreasing sensitivity of direct diagnostic tests (histopathology and/or immunohistochemistry [IHC], rapid urease test [RUT], and culture, several indirect tests, including antibody-based tests (serology and urine test, urea breath test (UBT, and stool antigen test (SAT have been developed to diagnose H. pylori infection. Among the indirect tests, UBT and SAT became the best methods to determine active infection. While antibody-based tests, especially serology, are widely available and relatively sensitive, their specificity is low. Guidelines indicated that no single test can be considered as the gold standard for the diagnosis of H. pylori infection and that one should consider the method’s advantages and disadvantages. Based on four epidemiological studies, culture and RUT present a sensitivity of 74.2–90.8% and 83.3–86.9% and a specificity of 97.7–98.8% and 95.1–97.2%, respectively, when using IHC as a gold standard. The sensitivity of serology is quite high, but that of the urine test was lower compared with that of the other methods. Thus, indirect test validation is important although some commercial kits propose universal cut-off values.

  14. Development of a standardized method for motion testing in pulse oximeters.

    Science.gov (United States)

    Shang, Allan B; Kozikowski, Raymond T; Winslow, Andrew W; Weininger, Sandy

    2007-12-01

    Pulse oximeter performance in the presence of motion varies among devices and manufacturers because of variations in hardware, software, testing, and calibration. Compounding these differences is a lack of uniform characterization of motion, and the consequential effects of motion upon the wide range of normal and abnormal human physiology. Traditional motion testing attempts to standardize motion into a reproducible form by using a mechanical jig to produce passive motion of a known amplitude and frequency. This type of motion challenge fails to account for the physiologic changes induced by active movement. We postulate that a more appropriate method for testing the performance of pulse oximeters in the presence of motion is to create a feedback control loop between the device and the test subject, providing a reproducible, actively created, and controlled motion test suitable for standardized testing among manufacturers. It is hoped that relying on a signal as seen from the oximeter's perspective will enable the creation of a sensitive and reproducible test method capable of separating those oximeters that can reject motion artifact from those that cannot. Preliminary results have concentrated on building the tools and clinical protocols needed to evaluate this method. Some basic observations are reported, but insufficient numbers of experienced subjects precludes rigorous conclusions. We have set the stage for a feasibility demonstration using a novel form of testing. With sufficient subjects and proper statistical evaluation, a robust test method for assessing the performance of pulse oximeters in the presence of motion may be at hand.

  15. Entropy Based Test Point Evaluation and Selection Method for Analog Circuit Fault Diagnosis

    Directory of Open Access Journals (Sweden)

    Yuan Gao

    2014-01-01

    Full Text Available By simplifying tolerance problem and treating faulty voltages on different test points as independent variables, integer-coded table technique is proposed to simplify the test point selection process. Usually, simplifying tolerance problem may induce a wrong solution while the independence assumption will result in over conservative result. To address these problems, the tolerance problem is thoroughly considered in this paper, and dependency relationship between different test points is considered at the same time. A heuristic graph search method is proposed to facilitate the test point selection process. First, the information theoretic concept of entropy is used to evaluate the optimality of test point. The entropy is calculated by using the ambiguous sets and faulty voltage distribution, determined by component tolerance. Second, the selected optimal test point is used to expand current graph node by using dependence relationship between the test point and graph node. Simulated results indicate that the proposed method more accurately finds the optimal set of test points than other methods; therefore, it is a good solution to minimize the size of the test point set. To simplify and clarify the proposed method, only catastrophic and some specific parametric faults are discussed in this paper.

  16. Method and system for an on-chip AC self-test controller

    Energy Technology Data Exchange (ETDEWEB)

    Flanagan, John D.; Herring, Jay R.; Lo, Tin-Chee

    2006-06-06

    A method for performing AC self-test on an integrated circuit, including a system clock for use during normal operation. The method includes applying a long data capture pulse to a first test register in response to the system clock, and further applying at an speed data launch pulse to the first test register in response to the system clock. Inputting the data from the first register to a logic path in response to applying the at speed data launch pulse to the first test register. Applying at speed data capture pulse to a second test register in response to the system clock. Inputting the output from the logic path to the second test register in response to applying the at speed data capture pulse to the second register. Applying a long data launch pulse to the second test register in response to the system clock.

  17. A testing procedure for triaxial tests and a numerical method for the calculation of powder flow properties

    NARCIS (Netherlands)

    Eelkman Rooda, J.; Haaker, G.

    1977-01-01

    A testing procedure for measuring flow properties of powders is developed which makes it possible to use results from triaxial tests in the Jenike bin theory. For the elaboration of the results a numerical method is used, based upon the Warren Spring equation (τ/C)N = (σ + T)/T. In this equation σ

  18. Comparison of susceptibility patterns using commercially available susceptibility testing methods performed on prevalent Candida spp.

    Science.gov (United States)

    Cretella, David; Barber, Katie E; King, S Travis; Stover, Kayla R

    2016-12-01

    The rising rates of invasive fungal infections caused by non-albicans Candida and the increasing emergence of antifungal resistance complicate the management of invasive candidiasis. Accurate and timely antifungal susceptibility testing is critical to targeting antifungal therapy. The purpose of this study was to compare commercially available susceptibility testing methods using prospectively collected Candida isolates. Susceptibility testing was performed on 74 Candida isolates collected from July 2014 to March 2015 using broth microdilution according to the Clinical and Laboratory Standards Institute method, Etest, Vitek 2 (YS-05) and Sensititre. Essential agreement and categorical agreement (CA) were assessed using the reference method. Of the 34 total blood isolates collected, Candida albicans comprised only 38 % (13) of the Candida spp. with Candidaglabrata being nearly as prevalent (29 %, 10). CA using Etest was 86 % for fluconazole, 72 % for caspofungin, 98 % for micafungin and 97 % for anidulafungin. Vitek 2 CA was 90 % for fluconazole and 98 % for caspofungin. Sensititre CA was 93 % for fluconazole, 98 % for caspofungin, 98 % for micafungin and 100 % for anidulafungin. Although our study tested a small population of Candida isolates, our results were variable by method. When implementing antifungal susceptibility testing, clinicians should be aware of the strengths and limitations of each testing method.

  19. Standard test method for damage to contacting solid surfaces under fretting conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the studying or ranking the susceptibility of candidate materials to fretting corrosion or fretting wear for the purposes of material selection for applications where fretting corrosion or fretting wear can limit serviceability. 1.2 This test method uses a tribological bench test apparatus with a mechanism or device that will produce the necessary relative motion between a contacting hemispherical rider and a flat counterface. The rider is pressed against the flat counterface with a loading mass. The test method is intended for use in room temperature air, but future editions could include fretting in the presence of lubricants or other environments. 1.3 The purpose of this test method is to rub two solid surfaces together under controlled fretting conditions and to quantify the damage to both surfaces in units of volume loss for the test method. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5...

  20. SNSequate: Standard and Nonstandard Statistical Models and Methods for Test Equating

    Directory of Open Access Journals (Sweden)

    Jorge González

    2014-09-01

    Full Text Available Equating is a family of statistical models and methods that are used to adjust scores on two or more versions of a test, so that the scores from different tests may be used interchangeably. In this paper we present the R package SNSequate which implements both standard and nonstandard statistical models and methods for test equating. The package construction was motivated by the need of having a modular, simple, yet comprehensive, and general software that carries out traditional and new equating methods. SNSequate currently implements the traditional mean, linear and equipercentile equating methods, as well as the mean-mean, mean-sigma, Haebara and Stocking-Lord item response theory linking methods. It also supports the newest methods such as local equating, kernel equating, and item response theory parameter linking methods based on asymmetric item characteristic functions. Practical examples are given to illustrate the capabilities of the software. A list of other programs for equating is presented, highlighting the main differences between them. Future directions for the package are also discussed.

  1. Standard Test Method for Testing Polymeric Seal Materials for Geothermal and/or High Temperature Service Under Sealing Stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures. 1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068. 1.3 The test fluid is distilled water. 1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. A Comparative Study of Item Exposure Control Methods in Computerized Adaptive Testing.

    Science.gov (United States)

    Chang, Shun-Wen; Twu, Bor-Yaun

    This study investigated and compared the properties of five methods of item exposure control within the purview of estimating examinees' abilities in a computerized adaptive testing (CAT) context. Each of the exposure control algorithms was incorporated into the item selection procedure and the adaptive testing progressed based on the CAT design…

  3. Hot-mix asphalt testing for the South African pavement design method

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2010-08-01

    Full Text Available of local and international hot-mix asphalt (HMA) test methods and modify or adapt them to suit South African road pavement conditions. This paper presents various laboratory HMA test protocols developed as part of the project to revise SAPDM. Large scale...

  4. New Test Method for Rotating Spray Head Performance in Tank Cleaning

    DEFF Research Database (Denmark)

    Stenby, Mette; Dethlefsen, Markus Wied; Jensen, Bo Boye Busk

    2011-01-01

    . The chosen medium was a mixture of commercially available toothpaste and tap water. This mixture meets the needed criteria. One issue with the mixture was a tendency to foam formation, however an anti-foam agent was successfully used. Final test method: Preparation of test medium; even spreading...

  5. A Model-Based Method for Content Validation of Automatically Generated Test Items

    Science.gov (United States)

    Zhang, Xinxin; Gierl, Mark

    2016-01-01

    The purpose of this study is to describe a methodology to recover the item model used to generate multiple-choice test items with a novel graph theory approach. Beginning with the generated test items and working backward to recover the original item model provides a model-based method for validating the content used to automatically generate test…

  6. Measurement of Dynamic Viscoelasticity of Full-Size Wood Composite Panels Using a Vibration Testing Method

    Science.gov (United States)

    Cheng Guan; Houjiang Zhang; John F. Hunt; Lujing Zhou; Dan Feng

    2016-01-01

    The dynamic viscoelasticity of full-size wood composite panels (WCPs) under the free-free vibrational state were determined by a vibration testing method. Vibration detection tests were performed on 194 pieces of three types of full-size WCPs (particleboard, medium density fiberboard, and plywood (PW)). The dynamic viscoelasticity from smaller specimens cut from the...

  7. VENOLIVA - Vehicle Noise Limit Values - comparison of two noise emission test methods. Final Report

    NARCIS (Netherlands)

    Roo, F. de; Dittrich, M.G.; Beek, P.J.G. van; Bosschaart, C.; Derksen. D.G.; Kievit, M. de

    2011-01-01

    The permissible sound level of road vehicles is part of the EU vehicle type approval legislation, as laid down in EU Directive 70/157/EEC [1] and in the UN-ECE Regulation No 51 [2] , which specifies the test method for the noise emission test. Since 1984 several studies [48] [49] [50] [51] [52

  8. TESTING OF FRAMED STRUCTURE PARTS OF COMPACT MUON SOLENOID BY NONDESTRUCTIVE METHOD

    Directory of Open Access Journals (Sweden)

    L. Larchenkov

    2013-01-01

    Full Text Available Suspension parts of a compact muon solenoid for Large Hadron Collider have been tested in the paper. The paper describes a steady-state and cyclic “tension-compression” load created by superconducting electromagnet with energy of 3 GJ and magnetic induction of 4 tesla. A nondestructive testing method has been applied in the paper.

  9. A region-based multiple testing method for hypotheses ordered in space or time

    NARCIS (Netherlands)

    Meijer, R.J.; Krebs, T.J.; Goeman, J.J.

    2015-01-01

    Abstract We present a multiple testing method for hypotheses that are ordered in space or time. Given such hypotheses, the elementary hypotheses as well as regions of consecutive hypotheses are of interest. These region hypotheses not only have intrinsic meaning but testing them also has the

  10. Evaluation of hydrogen embrittlement and temper embrittlement by key curve method in instrumented Charpy test

    Directory of Open Access Journals (Sweden)

    Makita A.

    2010-06-01

    Full Text Available Instrumented Charpy test was conducted on small sized specimen of 21/4Cr-1Mo steel. In the test the single specimen key curve method was applied to determine the value of fracture toughness for the initiation of crack extension with hydrogen free, KIC, and for hydrogen embrittlement cracking, KIH. Also the tearing modulus as a parameter for resistance to crack extension was determined. The role of these parameters was discussed at an upper shelf temperature and at a transition temperature. Then the key curve method combined with instrumented Charpy test was proven to be used to evaluate not only temper embrittlement but also hydrogen embrittlement.

  11. Test method development for structural characterization of fiber composites at high temperatures

    Science.gov (United States)

    Mandell, J. F.; Grande, D. H.; Edwards, B.

    1985-01-01

    Test methods used for structural characterization of polymer matrix composites can be applied to glass and ceramic matrix composites only at low temperatures. New test methods are required for tensile, compressive, and shear properties of fiber composites at high temperatures. A tensile test which should be useful to at least 1000 C has been developed and used to characterize the properties of a Nicalon/glass composite up to the matrix limiting temperature of 600 C. Longitudinal and transverse unidirectional composite data are presented and discussed.

  12. A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead

    OpenAIRE

    Jianbo Wu; Hui Fang; Long Li; Jie Wang; Xiaoming Huang; Yihua Kang; Yanhua Sun; Chaoqing Tang

    2017-01-01

    To meet the great needs for MFL (magnetic flux leakage) inspection of drill pipes at wellheads, a lift-off-tolerant MFL testing method is proposed and investigated in this paper. Firstly, a Helmholtz coil magnetization method and the whole MFL testing scheme are proposed. Then, based on the magnetic field focusing effect of ferrite cores, a lift-off-tolerant MFL sensor is developed and tested. It shows high sensitivity at a lift-off distance of 5.0 mm. Further, the follow-up high repeatabilit...

  13. Some important considerations in the development of stress corrosion cracking test methods.

    Science.gov (United States)

    Wei, R. P.; Novak, S. R.; Williams, D. P.

    1972-01-01

    Discussion of some of the precaution needs the development of fracture-mechanics based test methods for studying stress corrosion cracking involves. Following a review of pertinent analytical fracture mechanics considerations and of basic test methods, the implications for test corrosion cracking studies of the time-to-failure determining kinetics of crack growth and life are examined. It is shown that the basic assumption of the linear-elastic fracture mechanics analyses must be clearly recognized and satisfied in experimentation and that the effects of incubation and nonsteady-state crack growth must also be properly taken into account in determining the crack growth kinetics, if valid data are to be obtained from fracture-mechanics based test methods.

  14. Method of testing carbide inserts for premature fracture by face milling of cylindrical workpieces

    Science.gov (United States)

    Kitagawa, R.; Akasawa, T.; Okusa, K.

    1984-12-01

    Methods are proposed for face milling solid cylindrical workpieces or half-cut and hollow cylindrical workpieces prepared from rectangular blocks by continuously changing both or either of the angles of engagement and disengagement. Carbide inserts are tested for premature fracture before the onset of steady wear using these face-milling methods. The premature fracture indicates the insufficient toughness of carbides to perform a given machining job. As carbides of higher wear resistance have lower shock resistance in general, they must be tested for premature fracture due to the lack of toughness to select suitable carbides for specific cutting applications. The test results obtained under the present study show that the premature fracture of carbides, whose toughness was classified by static toughness tests, can be evaluated dynamically and easily by the proposed face-milling methods.

  15. Test Gas Generation from Pure Liquids: An Application-Oriented Overview of Methods in a Nutshell

    Directory of Open Access Journals (Sweden)

    Yue Li

    2012-01-01

    Full Text Available The generation of test gas from pure liquids has a wide variety of applications in laboratory and field experiments, for which the quality of the test gas is of significance. Therefore, various methods for test gas generation have been designed. Each method has unique advantages and disadvantages. Thus, a short overview is presented within the scope of this paper. Furthermore, a common bubbler system is presented, which was built to generate test gas from volatile organic compounds for experimental usage in laboratory applications. An analysis is conducted with respect to the generated concentrations at different temperatures and flow rates of the diluting gas. Accuracy and stability of this method are investigated.

  16. A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead

    Directory of Open Access Journals (Sweden)

    Jianbo Wu

    2017-01-01

    Full Text Available To meet the great needs for MFL (magnetic flux leakage inspection of drill pipes at wellheads, a lift-off-tolerant MFL testing method is proposed and investigated in this paper. Firstly, a Helmholtz coil magnetization method and the whole MFL testing scheme are proposed. Then, based on the magnetic field focusing effect of ferrite cores, a lift-off-tolerant MFL sensor is developed and tested. It shows high sensitivity at a lift-off distance of 5.0 mm. Further, the follow-up high repeatability MFL probing system is designed and manufactured, which was embedded with the developed sensors. It can track the swing movement of drill pipes and allow the pipe ends to pass smoothly. Finally, the developed system is employed in a drilling field for drill pipe inspection. Test results show that the proposed method can fulfill the requirements for drill pipe inspection at wellheads, which is of great importance in drill pipe safety.

  17. A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead.

    Science.gov (United States)

    Wu, Jianbo; Fang, Hui; Li, Long; Wang, Jie; Huang, Xiaoming; Kang, Yihua; Sun, Yanhua; Tang, Chaoqing

    2017-01-21

    To meet the great needs for MFL (magnetic flux leakage) inspection of drill pipes at wellheads, a lift-off-tolerant MFL testing method is proposed and investigated in this paper. Firstly, a Helmholtz coil magnetization method and the whole MFL testing scheme are proposed. Then, based on the magnetic field focusing effect of ferrite cores, a lift-off-tolerant MFL sensor is developed and tested. It shows high sensitivity at a lift-off distance of 5.0 mm. Further, the follow-up high repeatability MFL probing system is designed and manufactured, which was embedded with the developed sensors. It can track the swing movement of drill pipes and allow the pipe ends to pass smoothly. Finally, the developed system is employed in a drilling field for drill pipe inspection. Test results show that the proposed method can fulfill the requirements for drill pipe inspection at wellheads, which is of great importance in drill pipe safety.

  18. Projection Methods

    DEFF Research Database (Denmark)

    Wagner, Falko Jens; Poulsen, Mikael Zebbelin

    1999-01-01

    When trying to solve a DAE problem of high index with more traditional methods, it often causes instability in some of the variables, and finally leads to breakdown of convergence and integration of the solution. This is nicely shown in [ESF98, p. 152 ff.].This chapter will introduce projection...... methods as a way of handling these special problems. It is assumed that we have methods for solving normal ODE systems and index-1 systems....

  19. Mechanical testing of internal fixation devices: A theoretical and practical examination of current methods.

    Science.gov (United States)

    Grant, Caroline A; Schuetz, Michael; Epari, Devakar

    2015-11-26

    Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated interfragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. [Diagnostic testing methods for skill assessment in reading, writing, and arithmetic. A critical review].

    Science.gov (United States)

    Hemminger, U; Roth, E; Schneck, S; Jans, T; Warnke, A

    2000-08-01

    The diagnosis of a specific developmental disorder of reading, writing and arithmetic can be made based upon individually applied standardized methods for testing scholastic achievement and IQ. To make the choice of suitable methods easier for the administrator of the test, a critical survey of German-language methods for assessing skills in reading, writing and arithmetic is presented. Test intention and psychometric properties for scholastic achievement are summarized. The methods are assessed with regard to their utility in the diagnosis of congenital alexia and dyscalculia. Supplementary suggestions for clinical assessment are given. In summary, beyond the primary school area there is a lack of current standardized methods that meet the current standards of quality. Particularly the assessment of arithmetic skills above those of the 4th grade level require resorting to methods of dubious curricular validity. Coverage is once again better for the upper elementary and middle school levels. There is a need for new constructions, respectively a need to update published scholastic achievement tests.

  1. Computing methods

    CERN Document Server

    Berezin, I S

    1965-01-01

    Computing Methods, Volume 2 is a five-chapter text that presents the numerical methods of solving sets of several mathematical equations. This volume includes computation sets of linear algebraic equations, high degree equations and transcendental equations, numerical methods of finding eigenvalues, and approximate methods of solving ordinary differential equations, partial differential equations and integral equations.The book is intended as a text-book for students in mechanical mathematical and physics-mathematical faculties specializing in computer mathematics and persons interested in the

  2. MicroSEQ Salmonella spp. Detection Kit using the Pathatrix 10-Pooling Salmonella spp. Kit linked protocol method modification. Performance Tested Method 031001.

    Science.gov (United States)

    Wall, Jason; Conrad, Rick; Latham, Kathy; Liu, Eric

    2014-01-01

    Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time to results compared to traditional culture methods. The addition of a recirculating pooled immunomagnetic separation method prior to real-time PCR analysis increases processing output while reducing both cost and labor. This AOAC Research Institute method modification study validates the MicroSEQ Salmonella spp. Detection Kit [AOAC Performance Tested Method (PTM) 031001] linked with the Pathatrix 10-Pooling Salmonella spp. Kit (AOAC PTM 090203C) in diced tomatoes, chocolate, and deli ham. The Pathatrix 10-Pooling protocol represents a method modification of the enrichment portion of the MicroSEQ Salmonella spp. protocol. The results of the method modification were compared to standard cultural reference methods for diced tomatoes, chocolate, and deli ham. All three matrixes were analyzed in a paired study design. An additional set of chocolate test portions was analyzed using an alternative enrichment medium in an unpaired study design. For all matrixes tested, there were no statistically significant differences in the number of positive test portions detected by the modified candidate method compared to the appropriate reference method. The MicroSEQ Salmonella spp. protocol linked with the Pathatrix individual or 10-Pooling procedure demonstrated reliability as a rapid, simplified, method for the preparation of samples and subsequent detection of Salmonella in diced tomatoes, chocolate, and deli ham.

  3. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured by the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.

  4. TaqMan Salmonella enterica Detection Kit. Performance Tested Method 020803.

    Science.gov (United States)

    Tebbs, Robert S; Cao, Yan Y; Balachandran, Priva; Petrauskene, Olga

    2009-01-01

    Peanut butter spiked with Salmonella enterica ser. Typhimurium was prepared by an independent laboratory and sent to Applied Biosystems to determine the sensitivity and specificity of the TaqMan Salmonella enterica Detection Kit for detecting Salmonella in peanut butter. The samples were spiked at three levels: five no-spike (0 CFU/25 g); 20 low-spike (0.2 CFU/25 g); and 20 high-spike (2 CFU/25 g). They were coded to create a blind set of 45 samples. The samples were processed based on an unpaired test design that included enrichment in buffered peptone water for the candidate method and lactose broth for the reference method. In the candidate method, a 1 mL aliquot of enriched sample was extracted using PrepMan Ultra Sample Preparation Reagent; the sample was amplified on the Applied Biosystems 7500 real-time PCR system, and analyzed for detection of Salmonella using RapidFinder Version 1.0 software. All samples processed by the candidate method were confirmed by culture according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures. Sensitivity, specificity, and Chi-square analysis were calculated by combining candidate method results with those of the reference method that were collected by the independent laboratory. The TaqMan Salmonella enterica Detection Kit showed 40% sensitivity, 100% specificity, and a Chi-square value equal to 1.52. Chi-square analysis indicated the candidate method and the reference method were comparable. Although the candidate method sensitivity was only 40% when compared with the reference method (unpaired samples), the sensitivity was > 100% when the candidate method results were compared with those of the confirmation method (same sample enrichment).

  5. Standard test method for determining the superplastic properties of metallic sheet materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the procedure for determining the superplastic forming properties (SPF) of a metallic sheet material. It includes tests both for the basic SPF properties and also for derived SPF properties. The test for basic properties encompasses effects due to strain hardening or softening. 1.2 This test method covers sheet materials with thicknesses of at least 0.5 mm but not greater than 6 mm. It characterizes the material under a uni-axial tensile stress condition. Note 1—Most industrial applications of superplastic forming involve a multi-axial stress condition in a sheet; however it is more convenient to characterize a material under a uni-axial tensile stress condition. Tests should be performed in different orientations to the rolling direction of the sheet to ascertain initial anisotropy. 1.3 This method has been used successfully between strain rates of 10-5 to 10-1 per second. 1.4 This method has been used successfully on Aluminum and Titanium alloys. The use of the method wi...

  6. Standard test method for radiochemical determination of plutonium in Soil by alpha spectroscopy

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of plutonium in soils at levels of detection dependent on count time, sample size, detector, background, and tracer yield. This test method describes one acceptable approach to the determination of plutonium in soil. 1.2 This test method is designed for 10 g of soil, previously collected and treated as described in Practices C998 and C999, but sample sizes up to 50 g may be analyzed by this test method. This test method may not be able to completely dissolve all forms of plutonium in the soil matrix. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 9.

  7. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  8. The effect of progressive muscle relaxation method on test anxiety in nursing students.

    Science.gov (United States)

    Zargarzadeh, Maryam; Shirazi, Maryam

    2014-11-01

    Concerning the prevalence of test anxiety among nursing students and presence of stress in nursing education years, this study was conducted to determine the effect of progressive muscle relaxation method on test anxiety among nursing students of Isfahan University of Medical Sciences in 2013. This was a quasi-experimental study conducted in three stages on 49 male and female nursing students divided into two groups (study and control). In the pre-test stage, demographic data and Sarason anxiety questionnaires were filled by 94 students (of terms 3 and 4). Then, in the intervention stage, the students having test anxiety were assigned to two groups (study and control), and the progressive muscle relaxation method was performed in the experiment group in four sessions. Then, the students did this method two times a day until final exams, immediately following which they filled the self-reported checklists. On the first day of the final exams, test anxiety questionnaire was filled by the two groups again. The collected data were analyzed by the statistical tests, i.e. χ(2), paired t-test, independent sample t-test, Mann-Whitney and Wilcoxon tests, using SPSS 18. Independent t-test showed a significant difference in the mean scores of test anxiety after intervention between the two groups of study and control (P = 0.00), but this difference was not significant before intervention (P = 0.76). Also, in the study group, there was a significant difference in the mean scores of test anxiety before and after intervention (P = 0.00), but this difference was not significant in the control group (P = 0.09). Mann-Whitney test showed no significant difference in categorization of test anxiety scores before intervention in the study and control groups (P = 0.60), but the difference was significant after intervention (P = 0.00). Wilcoxon test showed a significant difference in categorization of test anxiety scores in the study group before and after intervention (P = 0.00), but

  9. Application of column tests and electrical resistivity methods for leachate transport monitoring

    Directory of Open Access Journals (Sweden)

    Wychowaniak Dorota

    2015-09-01

    Full Text Available Development of the human civilization leads to the pollution of environment. One of the contamination which are a real threat to soil and groundwater are leachates from landfills. In this paper the solute transport through soil was considered. For this purpose, the laboratory column tests of chlorides tracer and leachates transport on two soil samples have been carried out. Furthermore, the electrical resistivity method was applied as auxiliary tool to follow the movements of solute through the soil column what allowed to compare between the results obtained with column test method and electrical resistivity measurements. Breakthrough curves obtained by conductivity and resistivity methods represents similar trends which leads to the conclusion about the suitability of electrical resistivity methods for contamination transport monitoring in soil-water systems.

  10. Comparative Study of Impedance Eduction Methods, Part 2: NASA Tests and Methodology

    Science.gov (United States)

    Jones, Michael G.; Watson, Willie R.; Howerton, Brian M.; Busse-Gerstengarbe, Stefan

    2013-01-01

    A number of methods have been developed at NASA Langley Research Center for eduction of the acoustic impedance of sound-absorbing liners mounted in the wall of a flow duct. This investigation uses methods based on the Pridmore-Brown and convected Helmholtz equations to study the acoustic behavior of a single-layer, conventional liner fabricated by the German Aerospace Center and tested in the NASA Langley Grazing Flow Impedance Tube. Two key assumptions are explored in this portion of the investigation. First, a comparison of results achieved with uniform-flow and shear-flow impedance eduction methods is considered. Also, an approach based on the Prony method is used to extend these methods from single-mode to multi-mode implementations. Finally, a detailed investigation into the effects of harmonic distortion on the educed impedance is performed, and the results are used to develop guidelines regarding acceptable levels of harmonic distortion

  11. Generating and testing methods for consumer-oriented product development; Genererende en toetsingsmethoden voor consumentgerichte productontwikkeling

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process. [Dutch] Om een goed inzicht te krijgen in verschillende ontwerpmethoden die productontwikkelaars kunnen gebruiken om bruikbare domoticaproducten te kunnen ontwikkelen en toetsen, is een inventarisatie uitgevoerd naar de methoden die in Nederland worden gebruikt. De inventarisatie richt zich op twee categorieen methoden: (1) methoden om de gebruiker casu quo het probleem beter te leren kennen en nieuwe oplossingen te genereren, zogenaamde genererende methoden, en (2) methoden om oplossingen te evatueren (in verschillende fasen van het ontwerpproces), zogenaamde toetsingsmethoden. De eerste categorie methoden richt zich op het ontwerpproces: hoe kan de ontwerper tijdens het ontwerpproces de bruikbaarheid van (domotica)producten zoveel mogelijk realiseren? De tweede categorie methoden is erop gericht om een ontwerp (in wat voor vorm dan ook: tekening, prototype, functionele computeranimatie, enzovoort) te toetsen bij gebruikers. Het zijn methoden om een ontwerp, op verschillende momenten

  12. The surgical gowns and drapes of tomorrow. Specifying material performance and test methods.

    Science.gov (United States)

    Patel, S R; Urech, D; Werner, H P

    1998-09-01

    A mandatory European standard is being developed to establish basic requirements and test methods for disposable and reusable materials used for surgical gowns and drapes. Once this standard has been adopted, the continued use of cotton textiles and conventional cotton-polyester-mixed textiles will become questionable. This article outlines the proposed requirements and looks at alternative methods that use liquid-repellent micro-filament textiles or liquid-proof textile laminates.

  13. An Experimental Test of a Biodynamic Method of Weed Suppression: The Biodynamic Seed Peppers

    OpenAIRE

    Bruce Kenneth Kirchoff

    2016-01-01

    An experimental test of a biodynamic agriculture method of weed suppression was carried out in growth chambers to establish the feasibility of the method as a preliminary to field trials. Four generations of Brassica rapa plants were used in a randomized block design. Treated flats received ashed seeds prepared according to biodynamic indications. Seed weight and counts were measured at the end of each generation, and germination of the control and experimental seed was investigated at the en...

  14. A novel method for direct solder bump pull testing using lead-free solders

    Science.gov (United States)

    Turner, Gregory Alan

    This thesis focuses on the design, fabrication, and evaluation of a new method for testing the adhesion strength of lead-free solders, named the Isotraction Bump Pull method (IBP). In order to develop a direct solder joint-strength testing method that did not require customization for different solder types, bump sizes, specific equipment, or trial-and-error, a combination of two widely used and accepted standards was created. First, solder bumps were made from three types of lead free solder were generated on untreated copper PCB substrates using an in-house fabricated solder bump-on-demand generator, Following this, the newly developed method made use of a polymer epoxy to encapsulate the solder bumps that could then be tested under tension using a high precision universal vertical load machine. The tests produced repeatable and predictable results for each of the three alloys tested that were in agreement with the relative behavior of the same alloys using other testing methods in the literature. The median peak stress at failure for the three solders tested were 2020.52 psi, 940.57 psi, and 2781.0 psi, and were within one standard deviation of the of all data collected for each solder. The assumptions in this work that brittle fracture occurred through the Intermetallic Compound layer (IMC) were validated with the use of Energy-Dispersive X-Ray Spectrometry and high magnification of the fractured surface of both newly exposed sides of the test specimens. Following this, an examination of the process to apply the results from the tensile tests into standard material science equations for the fracture of the systems was performed..

  15. Method 59

    DEFF Research Database (Denmark)

    Kjellsson, G.

    1994-01-01

    OCDE/GD(94)41. Er supplerende rapport til rapport: The OECD Workshop on Methods for Monitoring Organisms in the Environment, Ottawa 14-17 September 1992. Environment Monograph 90.......OCDE/GD(94)41. Er supplerende rapport til rapport: The OECD Workshop on Methods for Monitoring Organisms in the Environment, Ottawa 14-17 September 1992. Environment Monograph 90....

  16. galerkin's methods

    African Journals Online (AJOL)

    user

    CSSS, CSCS, CCSS, CCSC and CCCC plates. (c) Future studies can employ the shape function presented herein and the Galerkin's method to analyze plate. (d) Future studies should use the shape function used herein and Galerkin's method to analyze plate on elastic foundation. (e) It is suggested that further work in this ...

  17. Progress toward the development and testing of source reconstruction methods for NIF neutron imaging.

    Science.gov (United States)

    Loomis, E N; Grim, G P; Wilde, C; Wilson, D C; Morgan, G; Wilke, M; Tregillis, I; Merrill, F; Clark, D; Finch, J; Fittinghoff, D; Bower, D

    2010-10-01

    Development of analysis techniques for neutron imaging at the National Ignition Facility is an important and difficult task for the detailed understanding of high-neutron yield inertial confinement fusion implosions. Once developed, these methods must provide accurate images of the hot and cold fuels so that information about the implosion, such as symmetry and areal density, can be extracted. One method under development involves the numerical inversion of the pinhole image using knowledge of neutron transport through the pinhole aperture from Monte Carlo simulations. In this article we present results of source reconstructions based on simulated images that test the methods effectiveness with regard to pinhole misalignment.

  18. Complementary methods for nondestructive testing of composite materials reinforced with carbon woven fibers

    Science.gov (United States)

    Steigmann, R.; Iftimie, N.; Sturm, R.; Vizureanu, P.; Savin, A.

    2015-11-01

    This paper presents complementary methods used in nondestructive evaluation (NDE) of composite materials reinforced with carbon woven fibers as two electromagnetic methods using sensor with orthogonal coils and sensor with metamaterials lens as well as ultrasound phased array method and Fiber Bragg gratings embedded instead of a carbon fiber for better health monitoring. The samples were impacted with low energy in order to study delamination influence. The electromagnetic behavior of composite was simulated by finite- difference time-domain (FDTD) software, showing a very good concordance with electromagnetic nondestructive evaluation tests.

  19. Comparative rice seed toxicity tests using filter paper, growth pouch-tm, and seed tray methods

    Science.gov (United States)

    Wang, W.

    1993-01-01

    Paper substrate, especially circular filter paper placed inside a Petri dish, has long been used for the plant seed toxicity test (PSTT). Although this method is simple and inexpensive, recent evidence indicates that it gives results that are significantly different from those obtained using a method that does not involve paper, especially when testing metal cations. The study compared PSTT using three methods: filter paper, Growth Pouch-TM, and seed tray. The Growth Pouch-TM is a commercially available device. The seed tray is a newly designed plastic receptacle placed inside a Petri dish. The results of the Growth Pouch-TM method showed no toxic effects on rice for Ag up to 40 mg L-1 and Cd up to 20 mg L-1. Using the seed tray method, IC50 (50% inhibitory effect concentration) values were 0.55 and 1.4 mg L-1 for Ag and Cd, respectively. Although results of filter paper and seed tray methods were nearly identical for NaF, Cr(VI), and phenol, the toxicities of cations Ag and Cd were reduced by using the filter paper method; IC50 values were 22 and 18 mg L-1, respectively. The results clearly indicate that paper substrate is not advisable for PSTT.

  20. Existing and Past Methods of Test and Rating Standards Related to Integrated Heat Pump Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Reedy, Wayne R. [Sentech, Inc.

    2010-07-01

    This report evaluates existing and past US methods of test and rating standards related to electrically operated air, water, and ground source air conditioners and heat pumps, 65,000 Btu/hr and under in capacity, that potentiality incorporate a potable water heating function. Two AHRI (formerly ARI) standards and three DOE waivers were identified as directly related. Six other AHRI standards related to the test and rating of base units were identified as of interest, as they would form the basis of any new comprehensive test procedure. Numerous other AHRI and ASHRAE component test standards were also identified as perhaps being of help in developing a comprehensive test procedure.