WorldWideScience

Sample records for test detection ensuring

  1. Detective quantum efficiency: a standard test to ensure optimal detector performance and low patient exposures

    Science.gov (United States)

    Escartin, Terenz R.; Nano, Tomi F.; Cunningham, Ian A.

    2016-03-01

    The detective quantum efficiency (DQE), expressed as a function of spatial frequency, describes the ability of an x-ray detector to produce high signal-to-noise ratio (SNR) images. While regulatory and scientific communities have used the DQE as a primary metric for optimizing detector design, the DQE is rarely used by end users to ensure high system performance is maintained. Of concern is that image quality varies across different systems for the same exposures with no current measures available to describe system performance. Therefore, here we conducted an initial DQE measurement survey of clinical x-ray systems using a DQE-testing instrument to identify their range of performance. Following laboratory validation, experiments revealed that the DQE of five different systems under the same exposure level (8.0 μGy) ranged from 0.36 to 0.75 at low spatial frequencies, and 0.02 to 0.4 at high spatial frequencies (3.5 cycles/mm). Furthermore, the DQE dropped substantially with decreasing detector exposure by a factor of up to 1.5x in the lowest spatial frequency, and a factor of 10x at 3.5 cycles/mm due to the effect of detector readout noise. It is concluded that DQE specifications in purchasing decisions, combined with periodic DQE testing, are important factors to ensure patients receive the health benefits of high-quality images for low x-ray exposures.

  2. Detection of alloimmunization to ensure safer transfusion practice

    Directory of Open Access Journals (Sweden)

    Rashmi Sood

    2013-01-01

    Full Text Available Background: Serological safety is an integral part of overall safety for blood banks. Emphasis is on the use of routinue Red Blood Cell (RBC antibody screen test, at set time intervals, to reduce risks related to alloantibodies. Also emphasis is on importance of issuing antigen negative blood to alloantibody positive patients. Effect of using leucodepleted blood on the rate of alloimmunization is highlighted. The concept of provision of phenotypically matched blood is suggested. Materials and Methods: Antibody screen test is important to select appropriate blood for transfusion. Repeat antibody screen testing, except if time interval between the earlier and subsequent transfusion was less than 72 hours, followed by antibody identification, if required, was performed in patients being treated with repeat multiple blood transfusions. Between February 2008 and June 2009, repeat samples of 306 multi-transfused patients were analyzed. Search for irregular antibodies and reading of results was conducted using RBC panels (three-cell panel of Column Agglutination Technology (CAT and two cell panel of the Solid Phase Red Cell Adherence Technology (SPRCAT. Specificities of antibodies were investigated using appropriate panels, 11 cell panel of CAT and 16 cell panel of SPRCA. These technologies, detecting agglutination in columns and reactions in solid phase, evaluate the attachment of irregular incomplete antibody to antigen in the first phase of immunological reaction more directly and hence improve the reading of agglutination. Three to four log leuco reduced red blood cells were transfused to patients in the study using blood collection bags with integral filters. Results: Alloimmunization rate of 4.24% was detected from 306 multiply transfused patients tested and followed up. The Transfusion therapy may become significantly complicated. Conclusion: Red cell antibody screening and identification and subsequent issue of antigen negative blood have a

  3. Spatial regression test for ensuring temperature data quality in southern Spain

    Science.gov (United States)

    Estévez, J.; Gavilán, P.; García-Marín, A. P.

    2018-01-01

    Quality assurance of meteorological data is crucial for ensuring the reliability of applications and models that use such data as input variables, especially in the field of environmental sciences. Spatial validation of meteorological data is based on the application of quality control procedures using data from neighbouring stations to assess the validity of data from a candidate station (the station of interest). These kinds of tests, which are referred to in the literature as spatial consistency tests, take data from neighbouring stations in order to estimate the corresponding measurement at the candidate station. These estimations can be made by weighting values according to the distance between the stations or to the coefficient of correlation, among other methods. The test applied in this study relies on statistical decision-making and uses a weighting based on the standard error of the estimate. This paper summarizes the results of the application of this test to maximum, minimum and mean temperature data from the Agroclimatic Information Network of Andalusia (southern Spain). This quality control procedure includes a decision based on a factor f, the fraction of potential outliers for each station across the region. Using GIS techniques, the geographic distribution of the errors detected has been also analysed. Finally, the performance of the test was assessed by evaluating its effectiveness in detecting known errors.

  4. Tools to Ensure Safe Medicines: New Monograph Tests in USP-NF

    Directory of Open Access Journals (Sweden)

    Catherine Sheehan

    2010-06-01

    Full Text Available This paper describes USP-NF compendial updates to six ‘high-priority” excipient monographs: Glycerin, Propylene Glycol, Sorbitol Solution, Sorbitol Sorbitan Solution, Noncrystallizing Sorbitol Solution and Maltitol Solution. The USP-NF revisions arose from the Food and Drug Administration’s (FDA’s requests to include, as part of each monograph’s Identification test, a limit test to detect the presence of Diethylene Glycol (DEG, a toxic adulterant. These revisions align with the 2007 FDA Guidance for Industry: Testing of Glycerin for Diethylene Glycol (1, that drug product manufacturers perform a specific identity test for DEG on all containers of all lots of glycerin before glycerin is used in the manufacture and preparation of drug products. This paper describes several risk factors due to a complex global excipient supply chain, nonspecific specifications, inadequate supply chain qualification, and poor understanding of regulations. Strengthening and conformance to compendial specifications is one of the tools necessary to mitigate risk and help prevent the next DEG adulteration that is part of USP’s efforts to ensure safe medicines.

  5. Ensuring US National Aeronautics Test Capabilities

    Science.gov (United States)

    Marshall, Timothy J.

    2010-01-01

    process; and the reductions in wind tunnel testing requirements within the largest consumer of ATP wind tunnel test time, the Aeronautics Research Mission Directorate (ARMD). Retirement of the Space Shuttle Program and recent perturbations of NASA's Constellation Program will exacerbate this downward trend. Therefore it is crucial that ATP periodically revisit and determine which of its test capabilities are strategically important, which qualify as low-risk redundancies that could be put in an inactive status or closed, and address the challenges associated with both sustainment and improvements to the test capabilities that must remain active. This presentation will provide an overview of the ATP vision, mission, and goals as well as the challenges and opportunities the program is facing both today and in the future. We will discuss the strategy ATP is taking over the next five years to address the National aeronautics test capability challenges and what the program will do to capitalize on its opportunities to ensure a ready, robust and relevant portfolio of National aeronautics test capabilities.

  6. Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice sets forth requirements to ensure consistency in neutron-induced displacement damage testing of silicon and gallium arsenide electronic piece parts. This requires controls on facility, dosimetry, tester, and communications processes that affect the accuracy and reproducibility of these tests. It provides background information on the technical basis for the requirements and additional recommendations on neutron testing. In addition to neutrons, reactors are used to provide gamma-ray pulses of intensities and durations that are not achievable elsewhere. This practice also provides background information and recommendations on gamma-ray testing of electronics using nuclear reactors. 1.2 Methods are presented for ensuring and validating consistency in neutron displacement damage testing of electronic parts such as integrated circuits, transistors, and diodes. The issues identified and the controls set forth in this practice address the characterization and suitability of the radiation environm...

  7. Hypothesis tests for the detection of constant speed radiation moving sources

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir; Boudergui, Karim; Sannie, Guillaume; Gameiro, Jordan; Normand, Stephane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 99 Gif-sur-Yvette, (France); Mechin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 4050 Caen, (France)

    2015-07-01

    Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)

  8. Testing effort dependent software reliability model for imperfect debugging process considering both detection and correction

    International Nuclear Information System (INIS)

    Peng, R.; Li, Y.F.; Zhang, W.J.; Hu, Q.P.

    2014-01-01

    This paper studies the fault detection process (FDP) and fault correction process (FCP) with the incorporation of testing effort function and imperfect debugging. In order to ensure high reliability, it is essential for software to undergo a testing phase, during which faults can be detected and corrected by debuggers. The testing resource allocation during this phase, which is usually depicted by the testing effort function, considerably influences not only the fault detection rate but also the time to correct a detected fault. In addition, testing is usually far from perfect such that new faults may be introduced. In this paper, we first show how to incorporate testing effort function and fault introduction into FDP and then develop FCP as delayed FDP with a correction effort. Various specific paired FDP and FCP models are obtained based on different assumptions of fault introduction and correction effort. An illustrative example is presented. The optimal release policy under different criteria is also discussed

  9. Radiation legacy of nuclear tests at the Semipalatinsk test site in the light of requirements ensuring radiation safety performance

    International Nuclear Information System (INIS)

    Logachev, V.A.; Logacheva, L.A.

    2005-01-01

    Peculiarities of nuclear tests radiation legacy at the Semipalatinsk test site (STS) are shown in the light of performance of requirements ensuring radiation safety, decrease radiation contamination levels in environment and minimize exposure of radiation for population residing contaminated areas by radioactive fallout. The paper provides data on characterization of peculiarities of the STS operation legacy based on review of archival data of the former 3-d General Administration under USSR Ministry of Health. (author)

  10. Standards for Radiation Effects Testing: Ensuring Scientific Rigor in the Face of Budget Realities and Modern Device Challenges

    Science.gov (United States)

    Lauenstein, J M.

    2015-01-01

    An overview is presented of the space radiation environment and its effects on electrical, electronic, and electromechanical parts. Relevant test standards and guidelines are listed. Test standards and guidelines are necessary to ensure best practices, minimize and bound systematic and random errors, and to ensure comparable results from different testers and vendors. Test standards are by their nature static but exist in a dynamic environment of advancing technology and radiation effects research. New technologies, failure mechanisms, and advancement in our understanding of known failure mechanisms drive the revision or development of test standards. Changes to standards must be weighed against their impact on cost and existing part qualifications. There must be consensus on new best practices. The complexity of some new technologies exceeds the scope of existing test standards and may require development of a guideline specific to the technology. Examples are given to illuminate the value and limitations of key radiation test standards as well as the challenges in keeping these standards up to date.

  11. Design and test of a capacitance detection circuit based on a transimpedance amplifier

    International Nuclear Information System (INIS)

    Mu Linfeng; Zhang Wendong; He Changde; Zhang Rui; Song Jinlong; Xue Chenyang

    2015-01-01

    This paper presents a transimpedance amplifier (TIA) capacitance detection circuit aimed at detecting micro-capacitance, which is caused by ultrasonic stimulation applied to the capacitive micro-machined ultrasonic transducer (CMUT). In the capacitance interface, a TIA is adopted to amplify the received signal with a center frequency of 400 kHz, and finally detect ultrasound pressure. The circuit has a strong anti-stray property and this paper also studies the calculation of compensation capacity in detail. To ensure high resolution, noise analysis is conducted. After optimization, the detected minimum ultrasound pressure is 2.1 Pa, which is two orders of magnitude higher than the former. The test results showed that the circuit was sensitive to changes in ultrasound pressure and the distance between the CMUT and stumbling block, which also successfully demonstrates the functionality of the developed TIA of the analog-front-end receiver. (paper)

  12. Use of animals for toxicology testing is necessary to ensure patient safety in pharmaceutical development.

    Science.gov (United States)

    Mangipudy, Raja; Burkhardt, John; Kadambi, Vivek J

    2014-11-01

    There is an active debate in toxicology literature about the utility of animal testing vis-a-vis alternative in vitro paradigms. To provide a balanced perspective and add to this discourse it is important to review the current paradigms, explore pros and cons of alternatives, and provide a vision for the future. The fundamental goal of toxicity testing is to ensure safety in humans. In this article, IQ Consortium DruSafe, while submitting the view that nonclinical testing in animals is an important and critical component of the risk assessment paradigm in developing new drugs, also discusses its views on alternative approaches including a roadmap for what would be required to enhance the utilization of alternative approaches in the safety assessment process. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Selection of tests for outlier detection

    NARCIS (Netherlands)

    Bossers, H.C.M.; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    Integrated circuits are tested thoroughly in order to meet the high demands on quality. As an additional step, outlier detection is used to detect potential unreliable chips such that quality can be improved further. However, it is often unclear to which tests outlier detection should be applied and

  14. Usability Methods for Ensuring Health Information Technology Safety: Evidence-Based Approaches. Contribution of the IMIA Working Group Health Informatics for Patient Safety.

    Science.gov (United States)

    Borycki, E; Kushniruk, A; Nohr, C; Takeda, H; Kuwata, S; Carvalho, C; Bainbridge, M; Kannry, J

    2013-01-01

    Issues related to lack of system usability and potential safety hazards continue to be reported in the health information technology (HIT) literature. Usability engineering methods are increasingly used to ensure improved system usability and they are also beginning to be applied more widely for ensuring the safety of HIT applications. These methods are being used in the design and implementation of many HIT systems. In this paper we describe evidence-based approaches to applying usability engineering methods. A multi-phased approach to ensuring system usability and safety in healthcare is described. Usability inspection methods are first described including the development of evidence-based safety heuristics for HIT. Laboratory-based usability testing is then conducted under artificial conditions to test if a system has any base level usability problems that need to be corrected. Usability problems that are detected are corrected and then a new phase is initiated where the system is tested under more realistic conditions using clinical simulations. This phase may involve testing the system with simulated patients. Finally, an additional phase may be conducted, involving a naturalistic study of system use under real-world clinical conditions. The methods described have been employed in the analysis of the usability and safety of a wide range of HIT applications, including electronic health record systems, decision support systems and consumer health applications. It has been found that at least usability inspection and usability testing should be applied prior to the widespread release of HIT. However, wherever possible, additional layers of testing involving clinical simulations and a naturalistic evaluation will likely detect usability and safety issues that may not otherwise be detected prior to widespread system release. The framework presented in the paper can be applied in order to develop more usable and safer HIT, based on multiple layers of evidence.

  15. Optimized Environmental Test Sequences to Ensure the Sustainability and Reliability of Marine Weapons

    Directory of Open Access Journals (Sweden)

    Jung Ho Yang

    2014-11-01

    Full Text Available In recent years, there has been an increase in the types of marine weapons used in response to diverse hostile threats. However, because marine weapons are only tested under a single set of environmental conditions, failures due to different environmental stresses have been difficult to detect. Hence, this study proposes an environmental test sequence for multi-environment testing. The environmental test sequences for electrical units described in the international standard IEC 60068-1, and for military supply described in the United States national standard MIL-STD-810G were investigated to propose guidelines for the appropriate test sequences. This study demonstrated the need for tests in multiple environments by investigating marine weapon accidents, and evaluated which environmental stresses and test items have the largest impacts on marine weapons using a two-phase quality function deployment (QFD analysis of operational scenarios, environmental stresses, and environmental test items. Integer programming was used to determine the most influential test items and the shortest environmental test time, allowing us to propose optimal test procedures. Based on our analysis, we developed optimal environmental test sequences that could be selected by a test designer.

  16. Testing of defects in Si semiconductor apparatus by using single-photon detection

    International Nuclear Information System (INIS)

    Zhongliang, Pan; Ling, Chen; Guangju, Chen

    2013-01-01

    The failure analysis of semiconductor apparatus is very needed for ensuring product quality, which can find several types of defects in the semiconductor apparatus. A new testing method for the defects in Si semiconductor apparatus is presented in this paper, the method makes use of photon emissions to find out the failure positions or failure components by taking advantage of the infrared photo emission characteristics of semiconductor apparatus. These emitted photons carry the information of the apparatus structure. If there are defects in the apparatus, these photons can help in understanding the apparatus properties and detecting the defects. An algorithm for the generation of circuit input vectors are presented in this paper to enhance the strength of the emitted photons for the given components in the semiconductor apparatus. The multiple-valued logic, the static timing analysis and path sensitizations, are used in the algorithm. A lot of experimental results for the Si semiconductor apparatus show that many types of defects such as contact spiking and latchup failure etc., can be detected accurately by the method proposed in this paper

  17. Measures ensuring safety of the High Temperature Engineering Test Reactor (HTTR)

    International Nuclear Information System (INIS)

    1998-04-01

    JAERI has conducted research and development of an HTGR type reactor since 1969 under the project of the multi-purpose high-temperate gas-cooled experimental reactor, whose design was changed to the HTTR in 1985. The reactor license was granted by the Government in 1990 and the construction started next year. Various functions and performances have been tested since 1996 and the initial criticality achieved in 1998. This document consists of six chapters, describing safety matters examined in several development phases. The first chapter deals with succession of the multi-purpose experimental reactor technology and its exchange between JAERI and domestic industries. Chapter 2 reviews new technical findings after the licensing which were reflected to the current safety assessment. These technical items are given in the table form of extensive pages. Chapter 3 and 4 describe the performance tests and the criticality access, respectively. Chapter 5 and 6 deal with the detection of fuel failures and helium gas leaks, respectively. (H.Y.)

  18. A quench detection/logging system for the SSCL Magnet Test Laboratory

    International Nuclear Information System (INIS)

    Kim, K.; Coles, M.; Dryer, J.; Lambert, D.

    1994-01-01

    The quench in a magnet describes a process which occurs while the superconductivity state goes to the normal resistive state. The consequence of a quench is the conversion of the stored electromagnetic energy into heat. During this process the initiating point will reach a high temperature, which will char the insulation or melt the conductor and thereby destroy the magnet. To prevent the magnet from being lost, it is standard practice to observe several resistance and/or inductance voltages across the magnet as quench signatures - Detection. When a quench symptom is detected, protection operations are initiated: proper shutdown of the magnet excitation systems and treatment to dilute the heat energy at a spot - Protection. The temperature rise is diluted by firing heaters along the length of the magnet to ensure that the dissipated energy is spread. It is interesting that there is not a significant amount of published research on detection. To afford a more reliable quench detection system, two distinct approaches have been tried in the past: (i) Understanding of the Noise Mechanism and Sub-system Optimization, and (ii) Escaping from the Known Electromagnetic Noises by Observing Optical Waves or Acoustic Waves. The MTL of SSCL confronts a mass-measurement of about 10,000 production magnets. To meet the testing schedule, the false quench detection rate needs to be further optimized while the true quench detection rate remains secure for the magnet measurement safety. To meet these requirements, the authors followed an iterative top-down approach. First they defend the signal and noise characteristics of the quench phenomena by using existing software tools to build a rapid prototype system incorporating all proven functionality of the existing system. Then they further optimize the system through iterative upgrading based on their signal and noise character findings

  19. Multisignal detecting system of pile integrity testing

    Science.gov (United States)

    Liu, Zuting; Luo, Ying; Yu, Shihai

    2002-05-01

    The low strain reflection wave method plays a principal rule in the integrating detection of base piles. However, there are some deficiencies with this method. For example, there is a blind area of detection on top of the tested pile; it is difficult to recognize the defects at deep-seated parts of the pile; there is still the planar of 3D domino effect, etc. It is very difficult to solve these problems only with the single-transducer pile integrity testing system. A new multi-signal piles integrity testing system is proposed in this paper, which is able to impulse and collect signals on multiple points on top of the pile. By using the multiple superposition data processing method, the detecting system can effectively restrain the interference and elevate the precision and SNR of pile integrity testing. The system can also be applied to the evaluation of engineering structure health.

  20. Strategies for Ensuring Quality in the Business Education ...

    African Journals Online (AJOL)

    Strategies for Ensuring Quality in the Business Education Programme of Tertiary Institutions in ... The survey method was employed. One research question guided the study while two null hypotheses were tested at 0.05 degree of significance.

  1. Statistics of software vulnerability detection in certification testing

    Science.gov (United States)

    Barabanov, A. V.; Markov, A. S.; Tsirlov, V. L.

    2018-05-01

    The paper discusses practical aspects of introduction of the methods to detect software vulnerability in the day-to-day activities of the accredited testing laboratory. It presents the approval results of the vulnerability detection methods as part of the study of the open source software and the software that is a test object of the certification tests under information security requirements, including software for communication networks. Results of the study showing the allocation of identified vulnerabilities by types of attacks, country of origin, programming languages used in the development, methods for detecting vulnerability, etc. are given. The experience of foreign information security certification systems related to the detection of certified software vulnerabilities is analyzed. The main conclusion based on the study is the need to implement practices for developing secure software in the development life cycle processes. The conclusions and recommendations for the testing laboratories on the implementation of the vulnerability analysis methods are laid down.

  2. Co-Testing of Cervical Screening Tests in Detection of High Grade Cervical Intraepithelial Neoplasia

    Directory of Open Access Journals (Sweden)

    Smita Asthana

    2017-10-01

    Full Text Available Introduction: Co-testing performance for detection of high grade Cervical Intraepithelial Neoplasia (CIN has not been adequately addressed from Low Resource Countries (LRCs. Where isolated tests do not have adequate performance, further explorations are recommended. Aim: To evaluate the co-testing of conventional cervical screening tests such as Papanicolaou (Pap and Visual Inspection Cervix with Acetic Acid (VIA, with care HPV on Cervical Samples (CHPV or on Vaginal Samples (VHPV in the detection of high grade CIN. Materials and Methods: The cross-sectional study was conducted on ever married women of age 30 to 59 years in a rural community of Dadri. Women were screened by CHPV, VHPV, and Pap and VIA methods. Confirmation of screen positives was done by histology. Sensitivity, Specificity and likelihood ratios of different combinations of test determined to evaluate the performance. Results: Total eligible women, 66.2% (5032/7604 responded for screening. Analysis was performed on 4658, after excluding those who did not complete all screenings. Co-testing of CHPV (OR=246 or VHPV (OR=278 with Pap had highest association. Positive likelihood ratios of CHPV and VHPV with Pap in CIN II+ detection rates were 13.0 and 11.8 and in CIN III+ the detection rates were 18.0 and 16.0 respectively. Higher sensitivities and specificities were observed in co-testing for CIN III+ detection as against CIN II+ lesions. Conclusion: Choice of co-testing in a pair of tests for detection of high grade CIN is likely to depend on whether screening is targeted for developed or low resource country. VIA in isolation might not yield optimal results for LRCs.

  3. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    Science.gov (United States)

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical

  4. HIV resistance testing and detected drug resistance in Europe

    DEFF Research Database (Denmark)

    Schultze, Anna; Phillips, Andrew N; Paredes, Roger

    2015-01-01

    to Southern Europe. CONCLUSIONS: Despite a concurrent decline in virological failure and testing, drug resistance was commonly detected. This suggests a selective approach to resistance testing. The regional differences identified indicate that policy aiming to minimize the emergence of resistance......OBJECTIVES: To describe regional differences and trends in resistance testing among individuals experiencing virological failure and the prevalence of detected resistance among those individuals who had a genotypic resistance test done following virological failure. DESIGN: Multinational cohort...... study. METHODS: Individuals in EuroSIDA with virological failure (>1 RNA measurement >500 on ART after >6 months on ART) after 1997 were included. Adjusted odds ratios (aORs) for resistance testing following virological failure and aORs for the detection of resistance among those who had a test were...

  5. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Hodge, Chris A.

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  6. Detecting Test Tampering Using Item Response Theory

    Science.gov (United States)

    Wollack, James A.; Cohen, Allan S.; Eckerly, Carol A.

    2015-01-01

    Test tampering, especially on tests for educational accountability, is an unfortunate reality, necessitating that the state (or its testing vendor) perform data forensic analyses, such as erasure analyses, to look for signs of possible malfeasance. Few statistical approaches exist for detecting fraudulent erasures, and those that do largely do not…

  7. Detection and Analysis of the Quality of Ibuprofen Granules

    Science.gov (United States)

    Yu-bin, Ji; Xin, LI; Guo-song, Xin; Qin-bing, Xue

    2017-12-01

    The Ibuprofen Granules comprehensive quality testing to ensure that it is in accordance with the provisions of Chinese pharmacopoeia. With reference of Chinese pharmacopoeia, the Ibuprofen Granules is tested by UV, HPLC, in terms of grain size checking, volume deviation, weight loss on drying detection, dissolution rate detection, and quality evaluation. Results indicated that Ibuprofen Granules conform to the standards. The Ibuprofen Granules are qualified and should be permitted to be marketed.

  8. Test Analysis Tools to Ensure Higher Quality of On-Board Real Time Software for Space Applications

    Science.gov (United States)

    Boudillet, O.; Mescam, J.-C.; Dalemagne, D.

    2008-08-01

    EADS Astrium Space Transportation, in its Les Mureaux premises, is responsible for the French M51 nuclear deterrent missile onboard SW. There was also developed over 1 million of line of code, mostly in ADA, for the Automated Transfer Vehicle (ATV) onboard SW and the flight control SW of the ARIANE5 launcher which has put it into orbit. As part of the ATV SW, ASTRIUM ST has developed the first Category A SW ever qualified for a European space application. To ensure that all these embedded SW have been developed with the highest quality and reliability level, specific development tools have been designed to cover the steps of source code verification, automated validation test or complete target instruction coverage verification. Three of such dedicated tools are presented here.

  9. Fault detection in multiply-redundant measurement systems via sequential testing

    International Nuclear Information System (INIS)

    Ray, A.

    1988-01-01

    The theory and application of a sequential test procedure for fault detection and isolation. The test procedure is suited for development of intelligent instrumentation in strategic processes like aircraft and nuclear plants where redundant measurements are usually available for individual critical variables. The test procedure consists of: (1) a generic redundancy management procedure which is essentially independent of the fault detection strategy and measurement noise statistics, and (2) a modified version of sequential probability ratio test algorithm for fault detection and isolation, which functions within the framework of this redundancy management procedure. The sequential test procedure is suitable for real-time applications using commercially available microcomputers and its efficacy has been verified by online fault detection in an operating nuclear reactor. 15 references

  10. Statistical Requirements For Pass-Fail Testing Of Contraband Detection Systems

    International Nuclear Information System (INIS)

    Gilliam, David M.

    2011-01-01

    Contraband detection systems for homeland security applications are typically tested for probability of detection (PD) and probability of false alarm (PFA) using pass-fail testing protocols. Test protocols usually require specified values for PD and PFA to be demonstrated at a specified level of statistical confidence CL. Based on a recent more theoretical treatment of this subject [1], this summary reviews the definition of CL and provides formulas and spreadsheet functions for constructing tables of general test requirements and for determining the minimum number of tests required. The formulas and tables in this article may be generally applied to many other applications of pass-fail testing, in addition to testing of contraband detection systems.

  11. Nuclear power plant fire protection: fire detection (subsystems study Task 2)

    International Nuclear Information System (INIS)

    Berry, D.L.

    1977-12-01

    This report examines the adequacy of fire detection in the context of nuclear power plant safety. Topics considered are: (1) establishing area detection requirements, (2) selecting specific detector types, (3) locating and spacing detectors, and (4) performing installation tests and maintenance. Based on a thorough review of fire detection codes and standards and fire detection literature, the report concludes that current design and regulatory guidelines alone are insufficient to ensure satisfactory fire detection system performance. To assure adequate fire detection, this report recommends the use of in-place testing of detectors under conditions expected to occur normally in areas being protected

  12. Memory detection 2.0: the first web-based memory detection test.

    Science.gov (United States)

    Kleinberg, Bennett; Verschuere, Bruno

    2015-01-01

    There is accumulating evidence that reaction times (RTs) can be used to detect recognition of critical (e.g., crime) information. A limitation of this research base is its reliance upon small samples (average n = 24), and indications of publication bias. To advance RT-based memory detection, we report upon the development of the first web-based memory detection test. Participants in this research (Study1: n = 255; Study2: n = 262) tried to hide 2 high salient (birthday, country of origin) and 2 low salient (favourite colour, favourite animal) autobiographical details. RTs allowed to detect concealed autobiographical information, and this, as predicted, more successfully so than error rates, and for high salient than for low salient items. While much remains to be learned, memory detection 2.0 seems to offer an interesting new platform to efficiently and validly conduct RT-based memory detection research.

  13. Memory detection 2.0: the first web-based memory detection test.

    Directory of Open Access Journals (Sweden)

    Bennett Kleinberg

    Full Text Available There is accumulating evidence that reaction times (RTs can be used to detect recognition of critical (e.g., crime information. A limitation of this research base is its reliance upon small samples (average n = 24, and indications of publication bias. To advance RT-based memory detection, we report upon the development of the first web-based memory detection test. Participants in this research (Study1: n = 255; Study2: n = 262 tried to hide 2 high salient (birthday, country of origin and 2 low salient (favourite colour, favourite animal autobiographical details. RTs allowed to detect concealed autobiographical information, and this, as predicted, more successfully so than error rates, and for high salient than for low salient items. While much remains to be learned, memory detection 2.0 seems to offer an interesting new platform to efficiently and validly conduct RT-based memory detection research.

  14. Test performance of faecal occult blood testing for the detection of bowel cancer in people with chronic kidney disease (DETECT protocol

    Directory of Open Access Journals (Sweden)

    Williams Narelle

    2011-06-01

    Full Text Available Abstract Background Cancer is a major cause of mortality and morbidity in patients with chronic kidney disease (CKD. In patients without kidney disease, screening is a major strategy for reducing the risk of cancer and improving the health outcomes for those who developed cancers by detecting treatable cancers at an early stage. Among those with CKD, the effectiveness, the efficacy and patients' preferences for cancer screening are unknown. Methods/Design This work describes the protocol for the DETECT study examining the effectiveness, efficiency and patient's perspectives of colorectal cancer screening using immunochemical faecal occult blood testing (iFOBT for people with CKD. The aims of the DETECT study are 1 to determine the test performance characteristics of iFOBT screening in individuals with CKD, 2 to estimate the incremental costs and health benefits of iFOBT screening in CKD compared to no screening and 3 to elicit patients' perspective for colorectal cancer screening in the CKD population. Three different study designs will be used to explore the uncertainties surrounding colorectal cancer screening in CKD. A diagnostic test accuracy study of iFOBT screening will be conducted across all stages of CKD in patients ages 35-70. Using individually collected direct healthcare costs and outcomes from the diagnostic test accuracy study, cost-utility and cost-effective analyses will be performed to estimate the costs and health benefits of iFOBT screening in CKD. Qualitative in-depth interviews will be undertaken in a subset of participants from the diagnostic test accuracy study to investigate the perspectives, experiences, attitudes and beliefs about colorectal cancer screening among individuals with CKD. Discussion The DETECT study will target the three major unknowns about early cancer detection in CKD. Findings from our study will provide accurate and definitive estimates of screening efficacy and efficiency for colorectal cancer, and

  15. MAFF sponsored research: detection tests for irradiated food

    International Nuclear Information System (INIS)

    Blackburn, C.M.; Holley, P.A.; Pryke, D.C.

    1993-01-01

    In their 1986 report on the safety and wholesomeness of irradiated food the UK Advisory Committee on Irradiated and Novel Foods (ACINF) recognised that a generally applicable test to determine if a food had been irradiated was not available. The committee considered that, although not a pre-requisite, the existence of a detection test would be a useful supplement to a control system and do much to reassure consumers; with this in mind ACINF recommended that detection methods should be kept under review. As a consequence, in 1987 the Ministry initiated a comprehensive R and D detection test programme. Over fifty papers have been published to date as a result of this programme. MAFF (Ministry Of Agriculture Fisheries and Food) has also been involved in other research associated with irradiation and food safety, some of which is described in this paper. This paper aims to give an overview of recent work funded under the food irradiation programme. Twelve projects have been supported over the last two years, ten of which involved the development of detection tests for irradiated food. A summary of these projects is presented: - Thermoluminescence; - Electron Spin Resonance; - 2-alkylcyclobutanones; -Determination Of Hydrogen; - Differential Scanning Calorimetry; - Limulus Amoebocyte Lysate; - DNA; - Pesticide Breakdown; - Neutron Irradiation; -Future Plans. (orig./vhe)

  16. Laser Obstacle Detection System Flight Testing

    National Research Council Canada - National Science Library

    Davis, Timothy

    2003-01-01

    ...). The Aviation Applied Technology Directorate (AATD) was contracted to mount the HELLAS sensor on the nose of a UH-60L Blackhawk helicopter and to conduct flight tests to evaluate the HELLAS obstacle detection sensor...

  17. Ensuring production-worthy OPC recipes using large test structure arrays

    Science.gov (United States)

    Cork, Christopher; Zimmermann, Rainer; Mei, Xin; Shahin, Alexander

    2007-03-01

    The continual shrinking of design rules as the industry follows Moore's Law and the associated need for low k1 processes, have resulted in more layout configurations becoming difficult to print within the required tolerances. OPC recipes have needed to become more complex as tolerances decreased and acceptable corrections harder to find with simple algorithms. With this complexity comes the possibility of coding errors and ensuring the solutions are truly general. OPC Verification tools can check the quality of a correction based on pre-determined specifications for CD variation, line-end pullback and Edge Placement Error and then highlight layout configuration where violations are found. The problem facing a Mask Tape-Out group is that they usually have little control over the Design Styles coming in. Different approaches to eliminating problematic layouts have included highly restrictive Design Rules [1], whereby certain pitches or orientations are disallowed. Now these design rules are either becoming too complex or they overly restrict the designer from benefiting from the reduced pitch of the new node. The tight link between Design and Mask Tape-Out found in Integrated Device Manufacturers [2] (IDMs) i.e. companies that control both design and manufacturing can do much to dictate manufacturing friendly layout styles, and push ownership of problem resolution back to design groups. In fact this has been perceived as such an issue that a new class of products for designers that perform Lithographic Compliance Check on design layout is an emerging technology [3]. In contrast to IDMs, Semiconductor Foundries are presented with a much larger variety of design styles and a set of Fabless customers who generally are less knowledgeable in terms of understanding the impact of their layout on manufacturability and how to correct issues. The robustness requirements of a foundry's OPC correction recipe, therefore needs to be greater than that for an IDM's tape-out group

  18. Oral-Fluid Thiol-Detection Test Identifies Underlying Active Periodontal Disease Not Detected by the Visual Awake Examination.

    Science.gov (United States)

    Queck, Katherine E; Chapman, Angela; Herzog, Leslie J; Shell-Martin, Tamara; Burgess-Cassler, Anthony; McClure, George David

    Periodontal disease in dogs is highly prevalent but can only be accurately diagnosed by performing an anesthetized oral examination with periodontal probing and dental radiography. In this study, 114 dogs had a visual awake examination of the oral cavity and were administered an oral-fluid thiol-detection test prior to undergoing a a full-mouth anesthetized oral examination and digital dental radiographs. The results show the visual awake examination underestimated the presence and severity of active periodontal disease. The thiol-detection test was superior to the visual awake examination at detecting the presence and severity of active periodontal disease and was an indicator of progression toward alveolar bone loss. The thiol-detection test detected active periodontal disease at early stages of development, before any visual cues were present, indicating the need for intervention to prevent periodontal bone loss. Early detection is important because without intervention, dogs with gingivitis (active periodontal disease) progress to irreversible periodontal bone loss (stage 2+). As suggested in the current AAHA guidelines, a thiol-detection test administered in conjunction with the visual awake examination during routine wellness examinations facilitates veterinarian-client communication and mitigates under-diagnosis of periodontal disease and underutilization of dental services. The thiol-detection test can be used to monitor the periodontal health status of the conscious patient during follow-up examinations based on disease severity.

  19. Test of TEDA, Tsunami Early Detection Algorithm

    Science.gov (United States)

    Bressan, Lidia; Tinti, Stefano

    2010-05-01

    Tsunami detection in real-time, both offshore and at the coastline, plays a key role in Tsunami Warning Systems since it provides so far the only reliable and timely proof of tsunami generation, and is used to confirm or cancel tsunami warnings previously issued on the basis of seismic data alone. Moreover, in case of submarine or coastal landslide generated tsunamis, which are not announced by clear seismic signals and are typically local, real-time detection at the coastline might be the fastest way to release a warning, even if the useful time for emergency operations might be limited. TEDA is an algorithm for real-time detection of tsunami signal on sea-level records, developed by the Tsunami Research Team of the University of Bologna. The development and testing of the algorithm has been accomplished within the framework of the Italian national project DPC-INGV S3 and the European project TRANSFER. The algorithm is to be implemented at station level, and it is based therefore only on sea-level data of a single station, either a coastal tide-gauge or an offshore buoy. TEDA's principle is to discriminate the first tsunami wave from the previous background signal, which implies the assumption that the tsunami waves introduce a difference in the previous sea-level signal. Therefore, in TEDA the instantaneous (most recent) and the previous background sea-level elevation gradients are characterized and compared by proper functions (IS and BS) that are updated at every new data acquisition. Detection is triggered when the instantaneous signal function passes a set threshold and at the same time it is significantly bigger compared to the previous background signal. The functions IS and BS depend on temporal parameters that allow the algorithm to be adapted different situations: in general, coastal tide-gauges have a typical background spectrum depending on the location where the instrument is installed, due to local topography and bathymetry, while offshore buoys are

  20. Loop-Mediated Isothermal Amplification for Detection of Endogenous Sad1 Gene in Cotton: An Internal Control for Rapid Onsite GMO Testing.

    Science.gov (United States)

    Singh, Monika; Bhoge, Rajesh K; Randhawa, Gurinderjit

    2018-04-20

    Background : Confirming the integrity of seed samples in powdered form is important priorto conducting a genetically modified organism (GMO) test. Rapid onsite methods may provide a technological solution to check for genetically modified (GM) events at ports of entry. In India, Bt cotton is the commercialized GM crop with four approved GM events; however, 59 GM events have been approved globally. GMO screening is required to test for authorized GM events. The identity and amplifiability of test samples could be ensured first by employing endogenous genes as an internal control. Objective : A rapid onsite detection method was developed for an endogenous reference gene, stearoyl acyl carrier protein desaturase ( Sad1 ) of cotton, employing visual and real-time loop-mediated isothermal amplification (LAMP). Methods : The assays were performed at a constant temperature of 63°C for 30 min for visual LAMP and 62ºC for 40 min for real-time LAMP. Positive amplification was visualized as a change in color from orange to green on addition of SYBR ® Green or detected as real-time amplification curves. Results : Specificity of LAMP assays was confirmed using a set of 10 samples. LOD for visual LAMP was up to 0.1%, detecting 40 target copies, and for real-time LAMP up to 0.05%, detecting 20 target copies. Conclusions : The developed methods could be utilized to confirm the integrity of seed powder prior to conducting a GMO test for specific GM events of cotton. Highlights : LAMP assays for the endogenous Sad1 gene of cotton have been developed to be used as an internal control for onsite GMO testing in cotton.

  1. The role of hazard- and risk-based approaches in ensuring food safety

    NARCIS (Netherlands)

    Barlow, S.M.; Boobis, A.R.; Bridges, J.; Cockburn, A.; Dekant, W.; Hepburn, P.; Houben, G.F.; König, J.; Nauta, M.J.; Schuermans, J.; Bánáti, D.

    2015-01-01

    Background: Food legislation in the European Union and elsewhere includes both hazard- and risk-based approaches for ensuring safety. In hazard-based approaches, simply the presence of a potentially harmful agent at a detectable level in food is used as a basis for legislation and/or risk management

  2. Kaiser Permanente Creatinine Safety Program: A Mechanism to Ensure Widespread Detection and Care for Chronic Kidney Disease.

    Science.gov (United States)

    Sim, John J; Rutkowski, Mark P; Selevan, David C; Batech, Michael; Timmins, Royann; Slezak, Jeff M; Jacobsen, Steven J; Kanter, Michael H

    2015-11-01

    Chronic kidney disease is highly prevalent but is challenging to diagnose because of the need to establish chronicity. Within the current healthcare environment, a single abnormal creatinine measurement often can go without a follow-up, which can lead to missed diagnoses or diagnostic errors. The Kaiser Permanente Southern California creatinine safety program (the Creatinine SureNet) was created to help ensure that all single abnormal creatinine results had a follow-up evaluation. In the period February 1, 2010, to March 1, 2014, the electronic health records were used to capture individuals with single abnormal creatinine results that went >90 days without a repeat measurement. A coordinated effort among a centralized regional nurse and providers was used to communicate with patients and order a repeat creatinine measurement. A total of 12,396 individuals were identified (84% ambulatory care encounters). A total of 6981 individuals (52%) followed up with a repeat measurement. Female patients, non-Hispanic whites, and older individuals were more likely to obtain a repeat measurement. Subsequently, 3668 individuals had chronic kidney disease confirmed. Within 6 months, 1550 patients had chart documentation of their chronic kidney disease and 336 patients had a nephrology consultation. The ambulatory care environment, given its high volume and various prioritizations, is an under-recognized area where diagnostic errors are not uncommon and failure to follow up on abnormal test results can occur routinely. The Kaiser Permanente Southern California Creatinine SureNet program leverages the electronic health records and its multidisciplinary resources in an effort to ensure that patients with potential chronic kidney disease are identified and managed properly. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Sequential detection of influenza epidemics by the Kolmogorov-Smirnov test

    Directory of Open Access Journals (Sweden)

    Closas Pau

    2012-10-01

    Full Text Available Abstract Background Influenza is a well known and common human respiratory infection, causing significant morbidity and mortality every year. Despite Influenza variability, fast and reliable outbreak detection is required for health resource planning. Clinical health records, as published by the Diagnosticat database in Catalonia, host useful data for probabilistic detection of influenza outbreaks. Methods This paper proposes a statistical method to detect influenza epidemic activity. Non-epidemic incidence rates are modeled against the exponential distribution, and the maximum likelihood estimate for the decaying factor λ is calculated. The sequential detection algorithm updates the parameter as new data becomes available. Binary epidemic detection of weekly incidence rates is assessed by Kolmogorov-Smirnov test on the absolute difference between the empirical and the cumulative density function of the estimated exponential distribution with significance level 0 ≤ α ≤ 1. Results The main advantage with respect to other approaches is the adoption of a statistically meaningful test, which provides an indicator of epidemic activity with an associated probability. The detection algorithm was initiated with parameter λ0 = 3.8617 estimated from the training sequence (corresponding to non-epidemic incidence rates of the 2008-2009 influenza season and sequentially updated. Kolmogorov-Smirnov test detected the following weeks as epidemic for each influenza season: 50−10 (2008-2009 season, 38−50 (2009-2010 season, weeks 50−9 (2010-2011 season and weeks 3 to 12 for the current 2011-2012 season. Conclusions Real medical data was used to assess the validity of the approach, as well as to construct a realistic statistical model of weekly influenza incidence rates in non-epidemic periods. For the tested data, the results confirmed the ability of the algorithm to detect the start and the end of epidemic periods. In general, the proposed test could

  4. Toxicity testing: the search for an in vitro alternative to animal testing.

    Science.gov (United States)

    May, J E; Xu, J; Morse, H R; Avent, N D; Donaldson, C

    2009-01-01

    Prior to introduction to the clinic, pharmaceuticals must undergo rigorous toxicity testing to ensure their safety. Traditionally, this has been achieved using in vivo animal models. However, besides ethical reasons, there is a continual drive to reduce the number of animals used for this purpose due to concerns such as the lack of concordance seen between animal models and toxic effects in humans. Adequate testing to ensure any toxic metabolites are detected can be further complicated if the agent is administered in a prodrug form, requiring a source of cytochrome P450 enzymes for metabolism. A number of sources of metabolic enzymes have been utilised in in vitro models, including cell lines, primary human tissue and liver extracts such as S9. This review examines current and new in vitro models for toxicity testing, including a new model developed within the authors' laboratory utilising HepG2 liver spheroids within a co-culture system to examine the effects of chemotherapeutic agents on other cell types.

  5. Performance demonstration tests for eddy current inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given

  6. Performance demonstration tests for eddy current inspection of steam generator tubing

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given.

  7. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  8. Evaluation of the white test for the intraoperative detection of bile leakage.

    Science.gov (United States)

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.

  9. Cascaded image analysis for dynamic crack detection in material testing

    Science.gov (United States)

    Hampel, U.; Maas, H.-G.

    Concrete probes in civil engineering material testing often show fissures or hairline-cracks. These cracks develop dynamically. Starting at a width of a few microns, they usually cannot be detected visually or in an image of a camera imaging the whole probe. Conventional image analysis techniques will detect fissures only if they show a width in the order of one pixel. To be able to detect and measure fissures with a width of a fraction of a pixel at an early stage of their development, a cascaded image analysis approach has been developed, implemented and tested. The basic idea of the approach is to detect discontinuities in dense surface deformation vector fields. These deformation vector fields between consecutive stereo image pairs, which are generated by cross correlation or least squares matching, show a precision in the order of 1/50 pixel. Hairline-cracks can be detected and measured by applying edge detection techniques such as a Sobel operator to the results of the image matching process. Cracks will show up as linear discontinuities in the deformation vector field and can be vectorized by edge chaining. In practical tests of the method, cracks with a width of 1/20 pixel could be detected, and their width could be determined at a precision of 1/50 pixel.

  10. Ensuring Integrity in AGU Publications and Compliance With Dual Publication Policy

    Science.gov (United States)

    Kumar, Praveen; Calais, Eric

    2011-03-01

    To ensure the highest standards for publication, AGU has begun screening manuscript submissions using CrossCheck (http://www.crossref.org/crosscheck.html) for possible verbatim use of previously published material. Water Resources Research and Geophysical Research Letters have tested this technology since summer 2010. It has proven very useful in ensuring the highest integrity in publication standards and compliance with the AGU dual publication policy (http://www.agu.org/pubs/authors/policies/dualpub_policy.shtml). According to Barbara Major, assistant director of journals, other AGU journals will adopt this screening process in the near future.

  11. DN detection during SLSF tests

    International Nuclear Information System (INIS)

    Braid, T.H.; Harper, H.A.; Wilson, R.E.; Baldwin, R.D.; Gilbert, D.M.; Baxter, D.E.; Gillins, R.L.; Jeffries, G.L.

    1982-01-01

    During two tests in the Sodium Loop Safety Facility (W2 and P4), two systems were operated to detect delayed neutrons from exposed fuel. One monitored directly the sodium in the in-pile loop with a transit delay from the flux region of approx.2 seconds; the other conducted a sample stream of sodium to external detectors with a transit delay which could be varied from approx.10 to approx. 40 seconds. Detectors of a wide range of sensitivity were operated in pulse and current mode; DN signals varying from 2 recoil to many grams of molten fuel could be recorded reliably without saturation. During the W2 and P4 tests a continuous DN record was made. Massive fuel failure signals were observed during reactor transients in both tests, including events interpreted as fuel melting and exposure of large areas. The steady signal from the blockage in P4 was studied as a function of reactor power and sodium temperature

  12. The Hepatitis Testing and Linkage-to-Care Data Review Process: An Approach to Ensuring the Quality of Program Data.

    Science.gov (United States)

    Mezzo, Jennifer L; Lamia, Tamara L; Danelski, Lisa L; Schipani, Anne Marie; Stokes, Scott A; Jacobs-Ware, Elizabeth D

    2016-01-01

    CDC's 2012 Hepatitis Testing and Linkage to Care (HepTLC) initiative was a nationally coordinated effort to conduct hepatitis B and hepatitis C screening, posttest counseling, and linkage to care at 34 U.S. sites. This project provided support for data management and monthly data reviews between awardees and a data manager, which facilitated monitoring of awardee progress and regular program improvement opportunities. CDC provided technical assistance to awardees for testing processes and program improvement, including Internet-based data submission, reporting software and data management to awardees, offering assistance with submitting, and reviewing data in real time. We describe how one awardee, AIDS Resource Center of Wisconsin (ARCW), used the data management process to improve data quality, inform testing processes and implementation, and measure and report missing variables from an online database. From October 2012 through July 2014, ARCW performed 2,255 HCV antibody (anti-HCV) tests and 244 HCV ribonucleic acid (RNA) tests as part of the HepTLC initiative. Participants who tested HCV RNA positive (n=189) were referred to medical care. At the end of the study, no records were missing for the anti-HCV test result or HCV RNA test result variables, and only one record was missing for those who were referred to medical care. Regular data review and monitoring by awardees and CDC-supported data managers provided opportunities for data quality and program improvement. Through regular data review, ARCW reduced the amount of missing data and promoted timely follow-up with participants testing positive for HCV to ensure receipt of results and linkage to care. Other programs can adopt a similar data management model.

  13. Algorithm To Ensure And Enforce Brute-Force Attack-Resilient Password In Routers

    OpenAIRE

    Mohammed Farik; ABM Shawkat Ali

    2015-01-01

    Abstract Issues of weak login passwords arising from default passwords in wired and wireless routers has been a concern for more than a decade. In this research we develop and test an algorithm to ensure and enforce passwords in routers that are resistant to brute-force attack. A comparative analysis is performed to show the improved strengths of passwords derived via this algorithm. Implementation of this algorithm in routers will ensure setup of brute-force attack resistant passwords.

  14. Automated High-Speed Video Detection of Small-Scale Explosives Testing

    Science.gov (United States)

    Ford, Robert; Guymon, Clint

    2013-06-01

    Small-scale explosives sensitivity test data is used to evaluate hazards of processing, handling, transportation, and storage of energetic materials. Accurate test data is critical to implementation of engineering and administrative controls for personnel safety and asset protection. Operator mischaracterization of reactions during testing contributes to either excessive or inadequate safety protocols. Use of equipment and associated algorithms to aid the operator in reaction determination can significantly reduce operator error. Safety Management Services, Inc. has developed an algorithm to evaluate high-speed video images of sparks from an ESD (Electrostatic Discharge) machine to automatically determine whether or not a reaction has taken place. The algorithm with the high-speed camera is termed GoDetect (patent pending). An operator assisted version for friction and impact testing has also been developed where software is used to quickly process and store video of sensitivity testing. We have used this method for sensitivity testing with multiple pieces of equipment. We present the fundamentals of GoDetect and compare it to other methods used for reaction detection.

  15. Fault tolerant system based on IDDQ testing

    Science.gov (United States)

    Guibane, Badi; Hamdi, Belgacem; Mtibaa, Abdellatif; Bensalem, Brahim

    2018-06-01

    Offline test is essential to ensure good manufacturing quality. However, for permanent or transient faults that occur during the use of the integrated circuit in an application, an online integrated test is needed as well. This procedure should ensure the detection and possibly the correction or the masking of these faults. This requirement of self-correction is sometimes necessary, especially in critical applications that require high security such as automotive, space or biomedical applications. We propose a fault-tolerant design for analogue and mixed-signal design complementary metal oxide (CMOS) circuits based on the quiescent current supply (IDDQ) testing. A defect can cause an increase in current consumption. IDDQ testing technique is based on the measurement of power supply current to distinguish between functional and failed circuits. The technique has been an effective testing method for detecting physical defects such as gate-oxide shorts, floating gates (open) and bridging defects in CMOS integrated circuits. An architecture called BICS (Built In Current Sensor) is used for monitoring the supply current (IDDQ) of the connected integrated circuit. If the measured current is not within the normal range, a defect is signalled and the system switches connection from the defective to a functional integrated circuit. The fault-tolerant technique is composed essentially by a double mirror built-in current sensor, allowing the detection of abnormal current consumption and blocks allowing the connection to redundant circuits, if a defect occurs. Spices simulations are performed to valid the proposed design.

  16. SCTI chemical leak detection test plan

    International Nuclear Information System (INIS)

    1981-01-01

    Tests will be conducted on the CRBRP prototype steam generator at SCTI to determine the effects of steam generator geometry on the response of the CRBRP chemical leak detection system to small water-to-sodium leaks in various regions of the steam generator. Specifically, small injections of hydrogen gas (simulating water leaks) will be made near the two tubesheets, and the effective transport times to the main stream exit and vent line hydrogen meters will be measured. The magnitude and time characteristics of the meters' response will also be measured. This information will be used by the Small Leak Protection Base Program (SG027) for improved predictions of meter response times and leak detection sensitivity

  17. Algorithm To Ensure And Enforce Brute-Force Attack-Resilient Password In Routers

    Directory of Open Access Journals (Sweden)

    Mohammed Farik

    2015-08-01

    Full Text Available Abstract Issues of weak login passwords arising from default passwords in wired and wireless routers has been a concern for more than a decade. In this research we develop and test an algorithm to ensure and enforce passwords in routers that are resistant to brute-force attack. A comparative analysis is performed to show the improved strengths of passwords derived via this algorithm. Implementation of this algorithm in routers will ensure setup of brute-force attack resistant passwords.

  18. A Space Object Detection Algorithm using Fourier Domain Likelihood Ratio Test

    Science.gov (United States)

    Becker, D.; Cain, S.

    Space object detection is of great importance in the highly dependent yet competitive and congested space domain. Detection algorithms employed play a crucial role in fulfilling the detection component in the situational awareness mission to detect, track, characterize and catalog unknown space objects. Many current space detection algorithms use a matched filter or a spatial correlator to make a detection decision at a single pixel point of a spatial image based on the assumption that the data follows a Gaussian distribution. This paper explores the potential for detection performance advantages when operating in the Fourier domain of long exposure images of small and/or dim space objects from ground based telescopes. A binary hypothesis test is developed based on the joint probability distribution function of the image under the hypothesis that an object is present and under the hypothesis that the image only contains background noise. The detection algorithm tests each pixel point of the Fourier transformed images to make the determination if an object is present based on the criteria threshold found in the likelihood ratio test. Using simulated data, the performance of the Fourier domain detection algorithm is compared to the current algorithm used in space situational awareness applications to evaluate its value.

  19. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Dawod, Alnazer Ahmed Ibrahim

    2014-12-01

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  20. Hydrogen peroxide test for intraoperative bile leak detection.

    Science.gov (United States)

    Trehan, V; Rao, Pankaj P; Naidu, C S; Sharma, Anuj K; Singh, A K; Sharma, Sanjay; Gaur, Amit; Kulkarni, S V; Pathak, N

    2017-07-01

    Bile leakage (BL) is a common complication following liver surgery, ranging from 3 to 27% in different series. To reduce the incidence of post-operative BL various BL tests have been applied since ages, but no method is foolproof and every method has their own limitations. In this study we used a relatively simpler technique to detect the BL intra-operatively. Topical application of 1.5% diluted hydrogen peroxide (H 2 O 2 ) was used to detect the BL from cut surface of liver and we compared this with conventional saline method to know the efficacy. A total of 31 patients included all patients who underwent liver resection and donor hepatectomies as part of Living Donor Liver Transplantation. After complete liver resection, the conventional saline test followed by topical diluted 1.5% H 2 O 2 test was performed on all. A BL was demonstrated in 11 patients (35.48%) by the conventional saline method and in 19 patients (61.29%) by H 2 O 2 method. Statistically compared by Wilcoxon signed-rank test showed significant difference ( P  = 0.014) for minor liver resections group and ( P  = 0.002) for major liver resections group. The topical application of H 2 O 2 is a simple and effective method of detection of BL from cut surface of liver. It is an easy, non-invasive, cheap, less time consuming, reproducible, and sensitive technique with no obvious disadvantages.

  1. Ensuring Sustainable Development through Urban Planning in Pakistan

    Directory of Open Access Journals (Sweden)

    Mohammad Qasim

    2013-04-01

    Full Text Available Urban planning includes land use management and environmental change. It makes arrangement for community facilities and services. Since, sustainable development has been included as a vital end product of all planning goals it also provides for balanced use of land, housing and transportation and better quality of life. Present urban planning in Pakistan is not ensuring sustainable development in Pakistan. This is tested through the case study of master planning in Rawalpindi and its implementation through housing schemes in Rawalpindi, Pakistan. Large portions of provisions of master plans are not implemented. This paper explains how the urban planning will be made enabled to ensure sustainable development in Pakistan. Six numbers of housing schemes and two squatter settlements have been surveyed through questionnaires, secondary data, the opinions of the experts from related fields and site observations. Amenities and social services at far distance, very less green area, Less quantity and bad quality of water, absence of comprehensive solid waste management and sewage disposal system and nontreatment of solid waste, effluent and sewage, prevalent unhygienic conditions and air and water pollution are the existing factors effecting the sustainability. There is a need to revisit the urban planning and a comprehensive Urban and Environment Planning Law at national level and at provincial level is recommended to enable the urban planning to ensure the sustainable development in Pakistan

  2. Ensuring sustainable development through urban planing in pakistan

    International Nuclear Information System (INIS)

    Qasim, M.; Zaidi, S.S.U.

    2013-01-01

    Urban planning includes land use management and environmental change. It makes arrangement for community facilities and services. Since, sustainable development has been included as a vital end product of all planning goals it also provides for balanced use of land, housing and transportation and better quality of life. Present urban planning in Pakistan is not ensuring sustainable development in Pakistan. This is tested through the case study of master planning in Rawalpindi and its implementation through housing schemes in Rawalpindi, Pakistan. Large portions of provisions of master plans are not implemented. This paper explains how the urban planning will be made enabled to ensure sustainable development in Pakistan. Six numbers of housing schemes and two squatter settlements have been surveyed through questionnaires, secondary data, the opinions of the experts from related fields and site observations. Amenities and social services at far distance, very less green area, Less quantity and bad quality of water, absence of comprehensive solid waste management and sewage disposal system and non- treatment of solid waste, effluent and sewage, prevalent unhygienic conditions and air and water pollution are the existing factors effecting the sustainability. There is a need to revisit the urban planning and a comprehensive Urban and Environment Planning Law at national level and at provincial level is recommended to enable the urban planning to ensure the sustainable development in Pakistan. (author)

  3. Accuracy analysis of the CTBTO nuclear test detection scale and Improvement

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Young Kwang [Seoul National Univ., Seoul (Korea, Republic of)

    2014-10-15

    CTBTO (Comprehensive nuclear Test Ban Treaty Organization) is charge of nuclear test monitoring for nuclear non-proliferation. CTBTO has 170 seismic stations in operation in 76 countries in order to detect the artificial earthquake that was caused by an underground nuclear test. Korea use formula that is based on the equations that are used by the IMS (International Monitoring System) of CTBTO for analysis of explosive scale, and reflect the nature of the terrain, such as rock. But the expression for calculating the exact scale explosive is still un-established state. And generally CTBTO doesn't care about artificial explosive that is being received low-yield in accordance with the criteria of nuclear detection. But, at the time that North Korea conduct a nuclear test, it should not be overlooked that the scale of the earthquake detection criteria below. Because DPRK is trying to conceal their nuclear development capability, there are possibility of low-yield nuclear test or possibility of install a buffer to hide actual explosive scale. These radionuclide observations were consistent with a DPRK low-yield nuclear test on May 2010, even though no seismic signals from such a test have been detected. But there were a few times of low-yield (magnitude 1.39-1.93) occurred around DPRK nuclear test site at that time.

  4. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    International Nuclear Information System (INIS)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-01-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation

  5. Water Pollution Detection Based on Hypothesis Testing in Sensor Networks

    Directory of Open Access Journals (Sweden)

    Xu Luo

    2017-01-01

    Full Text Available Water pollution detection is of great importance in water conservation. In this paper, the water pollution detection problems of the network and of the node in sensor networks are discussed. The detection problems in both cases of the distribution of the monitoring noise being normal and nonnormal are considered. The pollution detection problems are analyzed based on hypothesis testing theory firstly; then, the specific detection algorithms are given. Finally, two implementation examples are given to illustrate how the proposed detection methods are used in the water pollution detection in sensor networks and prove the effectiveness of the proposed detection methods.

  6. Detection Test for Leakage of CO2 into Sodium Loop

    International Nuclear Information System (INIS)

    Park, Sun Hee; Wi, Myung-Hwan; Min, Jae Hong

    2015-01-01

    This report is about the facility for the detection test for leakage of CO 2 into sodium loop. The facility for the detection test for leakage of CO 2 into sodium loop was introduced. The test will be carried out. Our experimental results are going to be expected to be used for approach methods to detect CO 2 leaking into sodium in heat exchangers. A sodium-and-carbon dioxide (Na-CO 2 ) heat exchanger is one of the key components for the supercritical CO 2 Brayton cycle power conversion system of sodium-cooled fast reactors (SFRs). A printed circuit heat exchanger (PCHE) is considered for the Na-CO 2 heat exchanger, which is known to have potential for reducing the volume occupied by the exchangers compared to traditional shell-and-tube heat exchangers. Among various issues about the Na- CO 2 exchanger, detection of CO 2 leaking into sodium in the heat exchanger is most important thing for its safe operation. It is known that reaction products from sodium and CO 2 such as sodium carbonate (Na 2 CO 3 ) and amorphous carbon are hardly soluble in sodium, which cause plug sodium channels. Detection technique for Na 2 CO 3 in sodium loop has not been developed yet. Therefore, detection of CO 2 and CO from reaction of sodium and CO 2 are proper to detect CO 2 leakage into sodium loop

  7. Internal factors influencing the knowledge continuity ensuring

    Directory of Open Access Journals (Sweden)

    Hana Urbancová

    2012-01-01

    Full Text Available The aim of the systematic ensuring of knowledge continuity is the continuity of an organisation’s development, the quality of managerial positions and the continuity of decision-making. By ensuring knowledge continuity, organisations may gain a performance-enhancing factor. The objective of the article is to identify the level of impact of decisive internal factors determining knowledge continuity ensuring and contributing to the efficiency of the organisations. Knowledge continuity ensuring as an internal force, however, can together with the right employees, help adapt more quickly to external conditions that organisations can hardly control. Monitoring and ensuring knowledge continuity can contribute to a higher quality of processes in general, in particular processes exploiting knowledge, and thus help improve the level of management. The first part of the article presents theoretical views on the aspects of knowledge continuity ensuring in organisations while the second part analyses the findings of the surveys carried out among managers in organisations in the Czech Republic. Based on the summary of the outcomes obtained it is possible to say that internal factors influence knowledge continuity ensuring in organisations, however, the level of impact of individual factors is determined by their size. The findings regarding the impact of each of the factors show that the most significant barriers to knowledge continuity ensuring are those associated with the human factor.

  8. Proof-testing strategies induced by dangerous detected failures of safety-instrumented systems

    International Nuclear Information System (INIS)

    Liu, Yiliu; Rausand, Marvin

    2016-01-01

    Some dangerous failures of safety-instrumented systems (SISs) are detected almost immediately by diagnostic self-testing as dangerous detected (DD) failures, whereas other dangerous failures can only be detected by proof-testing, and are therefore called dangerous undetected (DU) failures. Some items may have a DU- and a DD-failure at the same time. After the repair of a DD-failure is completed, the maintenance team has two options: to perform an insert proof test for DU-failure or not. If an insert proof test is performed, it is necessary to decide whether the next scheduled proof test should be postponed or performed at the scheduled time. This paper analyzes the effects of different testing strategies on the safety performance of a single channel of a SIS. The safety performance is analyzed by Petri nets and by approximation formulas and the results obtained by the two approaches are compared. It is shown that insert testing improves the safety performance of the channel, but the feasibility and cost of the strategy may be a hindrance to recommend insert testing. - Highlights: • Identify the tests induced by detected failures. • Model the testing strategies following DD-failures. • Propose analytical formulas for effects of strategies. • Simulate and verify the proposed models.

  9. Quench detection electronics testing protocol for SST-1 magnets

    International Nuclear Information System (INIS)

    Banaudha, Moni; Varmora, Pankaj; Parghi, Bhadresh; Prasad, Upendra

    2017-01-01

    Quench Detection (QD) system consisting 204 signal channels has been successfully installed and working well during plasma experiment of SST-1 Tokamak. QD system requires testing, validation and maintenance in every SST-1 campaign for better reliability and maintainability of the system. Standalone test of each channel of the system is essential for hard-ware validation. The standard Testing Protocol follow in every campaign which validate each section of QD electronics as well as voltage tap signal cables which are routed inside the cryostat and then extended outside of the SST-1 machine up-to the magnet control room. Fiber link for Quench signal transmission to the SST-1 magnet power supply is also test and validate before every plasma campaign. Precise instrument used as a dummy source of quench signal and for manual quench generation to test the each channel and Master Quench Logic. Each signal Integrated with the magnet DAQ system, signal observed at 1Hz and 50Hz configuration to validate the logging data, compare with actual and previous test data. This paper describes the testing protocol follow in every campaign to validate functionality of QD electronics, limitation of testing, test results and overall integration of the quench detection system for SST-1 magnet. (author)

  10. Imperfection detection probability at ultrasonic testing of reactor vessels

    International Nuclear Information System (INIS)

    Kazinczy, F. de; Koernvik, L.Aa.

    1980-02-01

    The report is a lecture given at a symposium organized by the Swedish nuclear power inspectorate on February 1980. Equipments, calibration and testing procedures are reported. The estimation of defect detection probability for ultrasonic tests and the reliability of literature data are discussed. Practical testing of reactor vessels and welded joints are described. Swedish test procedures are compared with other countries. Series of test data for welded joints of the OKG-2 reactor are presented. Future recommendations for testing procedures are made. (GBn)

  11. [Blood Test Patterns for Blood Donors after Nucleic Acid Detection in the Blood Center].

    Science.gov (United States)

    Men, Shou-Shan; Lv, Lian-Zhi; Chen, Yuan-Feng; Han, Chun-Hua; Liu, Hong-Yu; Yan, Yan

    2017-12-01

    To investigate the blood test patterns for blood donors after nucleic acid detection in blood center. The collected blood samples after voluntary blood donors first were detected by conventional ELISA, then 31981 negative samples were detected via HBV/HCV/HIV combined nucleic acid test of 6 mixed samples(22716 cases) or single samples(9265 cases) by means of Roche cobas s201 instrument. The combined detection method as follows: the blood samples were assayed by conventional nucleic acid test of 6 mixed samples, at same time, 6 mixed samples were treated with polyethylene glycol precipitation method to concentrate the virus, then the nucleic acid test of blood samples was performed; the single detection method as follows: firstly the conventional nucleic acid test of single sample was performed, then the positive reactive samples after re-examination were 6-fold diluted to simulate the nucleic acid test of 6-mixed samples. The positive rate of positive samples detected by combined nucleic acid test, positive samples detected by nucleic acid test of mixed virus concentration and positive samples detected by single nucleic acid test was statistically analyzed. In addition, for HBV + persons the serological test yet should be performed. In 22 716 samples detected by nucleic acid test of 6 mixed samples (MP-6-NAT) , 9 cases were HBV + (0.40‰, 9/22716); at same time, the detection of same samples by nucleic acid test of mixed sample virus concentration showed 29 cases of HBV + (1.28‰, 29/22716). In 9265 samples detected by single nucleic acid test(ID-NAT) 12 cases showed HBV + (1.30‰, 12/9265), meanwhile the detection of these 12 samples with HBV + by 6-fold dilution for virus concentration found only 4 samples with HBV + . In serological qualified samples, ID-NAT unqualified rate was 1.28‰, which was higher than that of MP-6-NAT(0.4‰) (χ 2 =8.11, P0.05). In 41 samples with HBsAg - HBV DNA + detected by ELISA, 36 samples were confirmed to be occult HBV

  12. A pdf-Free Change Detection Test Based on Density Difference Estimation.

    Science.gov (United States)

    Bu, Li; Alippi, Cesare; Zhao, Dongbin

    2018-02-01

    The ability to detect online changes in stationarity or time variance in a data stream is a hot research topic with striking implications. In this paper, we propose a novel probability density function-free change detection test, which is based on the least squares density-difference estimation method and operates online on multidimensional inputs. The test does not require any assumption about the underlying data distribution, and is able to operate immediately after having been configured by adopting a reservoir sampling mechanism. Thresholds requested to detect a change are automatically derived once a false positive rate is set by the application designer. Comprehensive experiments validate the effectiveness in detection of the proposed method both in terms of detection promptness and accuracy.

  13. Indirect micro-immunofluorescence test for detecting type-specific antibodies to herpes simplex virus.

    Science.gov (United States)

    Forsey, T; Darougar, S

    1980-02-01

    A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.

  14. Field test of a leak detection system: planning, execution and results

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio da Silva; Daniel; Melo Filho, Silvio A.; Niehues de Farias, Mauro; Pacheco, Anderson [Petrobas Transporte SA - TRANSPETRO, (Brazil)

    2010-07-01

    The OLAPA pipeline (Brazil) with its 97.6 km in length crosses difficult environment with a combination of mountain and dense forest. The non-detection of leaks in this kind of pipeline would have serious consequences. This pipeline was chosen for testing the performance of a new TRANSPETRO leak detection system. This paper reports the testing process of the new leakage detection method carried out on the OLAPA pipeline. TRANSPETRO decided to test the leakwarn system which is a computational pipeline monitoring (CPM) method which and can be integrated into their SCADA system. The CPM uses the mass balance principle with line pack change to analyze the pipeline operational parameters. The tests consisted of comparing the theoretical results with in-field results of alarm times obtained from controlled removal of product, simulating a real leak. Three leaks were tested in different states of operation and size of leak. It was found that the results were compatible with the expected alarm time.

  15. SIP threats detection system

    OpenAIRE

    Vozňák, Miroslav; Řezáč, Filip

    2010-01-01

    The paper deals with detection of threats in IP telephony, the authors developed a penetration testing system that is able to check up the level of protection from security threats in IP telephony. The SIP server is a key komponent of VoIP infrastructure and often becomes the aim of attacks and providers have to ensure the appropriate level of security. We have developed web-based penetration system which is able to check the SIP server if can face to the most common attacks.The d...

  16. Multianalyte Tests for the Early Detection of Cancer: Speedbumps and Barriers

    Directory of Open Access Journals (Sweden)

    Michael A. Tainsky

    2007-01-01

    Full Text Available It has become very clear that a single molecular event is inadequate to accurately predict the biology (or pathophysiology of cancer. Furthermore, using any single molecular event as a biomarker for the early detection of malignancy may not comprehensively identify the majority of individuals with that disease. Therefore, the fact that technologies have arisen that can simultaneously detect several, possibly hundreds, of biomarkers has propelled the field towards the development of multianalyte-based in vitro diagnostic early detection tests for cancer using body fl uids such as serum, plasma, sputum, saliva, or urine. These multianalyte tests may be based on the detection of serum autoantibodies to tumor antigens, the presence of cancer-related proteins in serum, or the presence of tumor-specific genomic changes that appear in plasma as free DNA. The implementation of non-invasive diagnostic approaches to detect early stage cancer may provide the physician with evidence of cancer, but the question arises as to how the information will affect the pathway of clinical intervention. The confirmation of a positive result from an in vitro diagnostic cancer test may involve relatively invasive procedures to establish a true cancer diagnosis. If in vitro diagnostic tests are proven to be both specific, i.e. rarely produce false positive results due to unrelated conditions, and sufficiently sensitive, i.e. rarely produce false negative results, then such screening tests offer the potential for early detection and personalized therapeutics using multiple disease-related targets with convenient and non-invasive means. Here we discuss the technical and regulatory barriers inherent in development of clinical multianalyte biomarker assays.

  17. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  18. Real time risk analysis of kick detection: Testing and validation

    International Nuclear Information System (INIS)

    Islam, Rakibul; Khan, Faisal; Venkatesan, Ramchandran

    2017-01-01

    Oil and gas development is moving into harsh and remote locations where the highest level of safety is required. A blowout is one of the most feared accidents in oil and gas developments projects. The main objective of this paper is to test and validate the kick detection of blowout risk assessment model using uniquely developed experimental results. Kick detection is a major part of the blowout risk assessment model. The accuracy and timeliness of kick detection are dependent on the monitoring of multiple downhole parameters such as downhole pressure, fluid density, fluid conductivity and mass flow rate. In the present study these four parameters are considered in different logical combinations to assess the occurrence of kick and associated blowout risk. The assessed results are compared against the experimental observations. It is observed that simultaneous monitoring of mass flow rate combined with any one the three parameters provides most reliable detection of kick and potential blowout likelihood. The current work presents the framework for a dynamic risk assessment and management model. Upon success testing of this approach at the pilot and field levels, this approach could provide a paradigm shift in drilling safety. - Highlights: • A novel dynamic risk model of kick detection and blowout prediction. • Testing and Validation of the risk model. • Application of the dynamic risk model.

  19. Management of vacuum leak-detection processes, calibration, and standards

    International Nuclear Information System (INIS)

    Wilson, N.G.

    1985-01-01

    Vacuum leak detection requires integrated management action to ensure the successful production of apparatus having required leak tightness. Implementation of properly planned, scheduled, and engineered procedures and test arrangements are an absolute necessity to prevent unexpected, impractical, technically inadequate, or unnecessarily costly incidents in leak-testing operations. The use of standard procedures, leak standards appropriate to the task, and accurate calibration systems or devices is necessary to validate the integrity of any leak-test procedure. In this paper, the need for implementing these practices is discussed using case histories of typical examples of large complex vacuum systems. Aggressive management practices are of primary importance throughout a project's life cycle to ensure the lowest cost; this includes successful leak testing of components. It should be noted that the opinions and conclusions expressed in this paper are those of the author and are not those of the Los Alamos National Laboratory or the Department of Energy

  20. A versatile omnibus test for detecting mean and variance heterogeneity.

    Science.gov (United States)

    Cao, Ying; Wei, Peng; Bailey, Matthew; Kauwe, John S K; Maxwell, Taylor J

    2014-01-01

    Recent research has revealed loci that display variance heterogeneity through various means such as biological disruption, linkage disequilibrium (LD), gene-by-gene (G × G), or gene-by-environment interaction. We propose a versatile likelihood ratio test that allows joint testing for mean and variance heterogeneity (LRT(MV)) or either effect alone (LRT(M) or LRT(V)) in the presence of covariates. Using extensive simulations for our method and others, we found that all parametric tests were sensitive to nonnormality regardless of any trait transformations. Coupling our test with the parametric bootstrap solves this issue. Using simulations and empirical data from a known mean-only functional variant, we demonstrate how LD can produce variance-heterogeneity loci (vQTL) in a predictable fashion based on differential allele frequencies, high D', and relatively low r² values. We propose that a joint test for mean and variance heterogeneity is more powerful than a variance-only test for detecting vQTL. This takes advantage of loci that also have mean effects without sacrificing much power to detect variance only effects. We discuss using vQTL as an approach to detect G × G interactions and also how vQTL are related to relationship loci, and how both can create prior hypothesis for each other and reveal the relationships between traits and possibly between components of a composite trait.

  1. Testing the system detection unit for measuring solid minerals bulk density

    Science.gov (United States)

    Voytyuk, I. N.; Kopteva, A. V.

    2017-10-01

    The paper provides a brief description of the system for measuring flux per volume of solid minerals via example of mineral coal. The paper discloses the operational principle of the detection unit. The paper provides full description of testing methodology, as well as practical implementation of the detection unit testing. This paper describes the removal of two data arrays via the channel of scattered anddirect radiation for the detection units of two generations. This paper describes Matlab software to determine the statistical characteristics of the studied objects. The mean value of pulses per cycles, and pulse counting inaccuracy relatively the mean value were determined for the calculation of the stability account of the detection units.

  2. Scintillating anticoincidence detection elements design and tests with muons and protons

    International Nuclear Information System (INIS)

    Gilliot, M.; Chabaud, J.; Baronick, J.P.; Colonges, S.; Laurent, P.

    2010-01-01

    Design, construction and tests of anticoincidence detection elements are presented. Initially planned to be used as active shielding parts of the anticoincidence detector of the Simbol-X mission, they are aimed to detect cosmic protons and provide veto signal against charged-particle background induced on imaging detectors. The sample is made of a scintillator plate into which grooves are machined and waveshifting fibers glued. The fibers are connected to multianode photomultiplier (PM) tubes. The tubes characteristics have been evaluated for this application. The device has been tested with atmospheric muons that deposit similar energy to that of cosmic protons thanks to a specially designed muon telescope also described in this paper. Tests have also been performed with protons of a tandem accelerator beam line. The response is on average above 10 photoelectrons, which is not complicated to detect, which allows very good detection efficiency as well as very good ability to reject noise. In addition many evolution and performance improvements appear possible.

  3. Scintillating anticoincidence detection elements design and tests with muons and protons

    Science.gov (United States)

    Gilliot, M.; Chabaud, J.; Baronick, J. P.; Colonges, S.; Laurent, P.

    2010-09-01

    Design, construction and tests of anticoincidence detection elements are presented. Initially planned to be used as active shielding parts of the anticoincidence detector of the Simbol-X mission, they are aimed to detect cosmic protons and provide veto signal against charged-particle background induced on imaging detectors. The sample is made of a scintillator plate into which grooves are machined and waveshifting fibers glued. The fibers are connected to multianode photomultiplier (PM) tubes. The tubes characteristics have been evaluated for this application. The device has been tested with atmospheric muons that deposit similar energy to that of cosmic protons thanks to a specially designed muon telescope also described in this paper. Tests have also been performed with protons of a tandem accelerator beam line. The response is on average above 10 photoelectrons, which is not complicated to detect, which allows very good detection efficiency as well as very good ability to reject noise. In addition many evolution and performance improvements appear possible.

  4. Scintillating anticoincidence detection elements design and tests with muons and protons

    Energy Technology Data Exchange (ETDEWEB)

    Gilliot, M., E-mail: mickael.gilliot@univ-reims.f [Laboratoire APC, AstroParticules and Cosmologie, Batiment Condorcet, 10 rue Alice Domont et Leonie Duquet, 75205 Paris Cedex 13 (France); Chabaud, J.; Baronick, J.P.; Colonges, S. [Laboratoire APC, AstroParticules and Cosmologie, Batiment Condorcet, 10 rue Alice Domont et Leonie Duquet, 75205 Paris Cedex 13 (France); Laurent, P. [Laboratoire APC, AstroParticules and Cosmologie, Batiment Condorcet, 10 rue Alice Domont et Leonie Duquet, 75205 Paris Cedex 13 (France); CEA/DSM/Irfu/SAp, CEA/Saclay, 91191 Gif-Sur-Yvette Cedex (France)

    2010-09-21

    Design, construction and tests of anticoincidence detection elements are presented. Initially planned to be used as active shielding parts of the anticoincidence detector of the Simbol-X mission, they are aimed to detect cosmic protons and provide veto signal against charged-particle background induced on imaging detectors. The sample is made of a scintillator plate into which grooves are machined and waveshifting fibers glued. The fibers are connected to multianode photomultiplier (PM) tubes. The tubes characteristics have been evaluated for this application. The device has been tested with atmospheric muons that deposit similar energy to that of cosmic protons thanks to a specially designed muon telescope also described in this paper. Tests have also been performed with protons of a tandem accelerator beam line. The response is on average above 10 photoelectrons, which is not complicated to detect, which allows very good detection efficiency as well as very good ability to reject noise. In addition many evolution and performance improvements appear possible.

  5. Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.

    Science.gov (United States)

    Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon

    2012-01-01

    Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment

  6. Evaluation of the White Test for the Intraoperative Detection of Bile Leakage

    OpenAIRE

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was c...

  7. AN AUTOMATED ROAD ROUGHNESS DETECTION FROM MOBILE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    P. Kumar

    2017-05-01

    Full Text Available Rough roads influence the safety of the road users as accident rate increases with increasing unevenness of the road surface. Road roughness regions are required to be efficiently detected and located in order to ensure their maintenance. Mobile Laser Scanning (MLS systems provide a rapid and cost-effective alternative by providing accurate and dense point cloud data along route corridor. In this paper, an automated algorithm is presented for detecting road roughness from MLS data. The presented algorithm is based on interpolating smooth intensity raster surface from LiDAR point cloud data using point thinning process. The interpolated surface is further processed using morphological and multi-level Otsu thresholding operations to identify candidate road roughness regions. The candidate regions are finally filtered based on spatial density and standard deviation of elevation criteria to detect the roughness along the road surface. The test results of road roughness detection algorithm on two road sections are presented. The developed approach can be used to provide comprehensive information to road authorities in order to schedule maintenance and ensure maximum safety conditions for road users.

  8. An Automated Road Roughness Detection from Mobile Laser Scanning Data

    Science.gov (United States)

    Kumar, P.; Angelats, E.

    2017-05-01

    Rough roads influence the safety of the road users as accident rate increases with increasing unevenness of the road surface. Road roughness regions are required to be efficiently detected and located in order to ensure their maintenance. Mobile Laser Scanning (MLS) systems provide a rapid and cost-effective alternative by providing accurate and dense point cloud data along route corridor. In this paper, an automated algorithm is presented for detecting road roughness from MLS data. The presented algorithm is based on interpolating smooth intensity raster surface from LiDAR point cloud data using point thinning process. The interpolated surface is further processed using morphological and multi-level Otsu thresholding operations to identify candidate road roughness regions. The candidate regions are finally filtered based on spatial density and standard deviation of elevation criteria to detect the roughness along the road surface. The test results of road roughness detection algorithm on two road sections are presented. The developed approach can be used to provide comprehensive information to road authorities in order to schedule maintenance and ensure maximum safety conditions for road users.

  9. Detection at a distance of atomic bomb tests

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, M E

    1954-01-01

    Nahmias describes the radioassay of air, rain, and snowfall as the basis for detecting atomic bomb tests. Tables and graphs give time vs. Ra equivalents, distance vs Roentgens/h of radiation, and distribution of radioelements which can be expected.

  10. Detection of ductile crack initiation by acoustic emission testing

    International Nuclear Information System (INIS)

    Richter, H.; Boehmert, J.; Viehrig, H.W.

    1998-08-01

    A Charpy impact test equipment is described permitting simultaneous measurement of impact force, crack tip opening, acoustic emissions and magnetic emissions. The core of the equipment is an inverted pendulum ram impact testing machine and the tests have been performed with laterally notched, pre-fatigue ISO-V specimens made of steels of various strength and toughness properties. The tests are intended to ascertain whether the acoustic emission method is suitable for detecting steady crack initiation in highly ductile steels. (orig./CB) [de

  11. Ensuring the 50 year life of a fissile material container

    International Nuclear Information System (INIS)

    Glass, R.E.; Towne, T.L.

    1997-12-01

    Sandia was presented with an opportunity in 1993 to design containers for the long term storage and transport of fissile material. This program was undertaken at the direction of the US Department of Energy and in cooperation with Lawrence Livermore National Laboratory and Los Alamos National Laboratory which were tasked with developing the internal fixturing for the contents. The hardware is being supplied by Allied Signal Federal Manufacturing and Technologies, and the packaging will occur at Mason and Hangar Corporation's Pantex Plant. The unique challenge was to design a container that could be sealed with the fissile material contents; and, anytime during the next 50 years, the container could be transported with only the need for the pre-shipment leak test. This required not only a rigorous design capable of meeting the long term storage and transportation requirements, but also resulted in development of a surveillance program to ensure that the container continues to perform as designed over the 50-year life. This paper addresses the design of the container, the testing that was undertaken to demonstrate compliance with US radioactive materials transport regulations, and the surveillance program that has been initiated to ensure the 50-year performance

  12. Testing laboratories, its function in ensuring industrial safety

    International Nuclear Information System (INIS)

    Sanchez Fernandez, M.

    2015-01-01

    This article discusses and justifies the development of industrial laboratories (testing and calibration) in Spain, since its embryo, its creation and development, to the present day. Likewise, presents its interrelation with other agents, as well as the legislative and technical framework is application along to the years. Within this development of the sector, highlights the period of the conformity assessment, and consequently its relationship with Industrial safety. Finally, describes the organizational situation of the sector both nationally and internationally. (Author)

  13. Advantages and disadvantages of current diagnostic tests for the detection of Helicobacter pylori.

    Science.gov (United States)

    Mégraud, F

    1996-01-01

    Current tests used to detect Helicobacter pylori are either invasive (histological detection, culture, the polymerase chain reaction (PCR), smear examination) or non-invasive (serology, 13C-urea breath test). These tests vary in their sensitivity and specificity, and the choice of test will depend on the situation, for example, whether the test is to detect infection or the success of eradication treatment. The accuracy of histological tests depends, to a large degree, on the expertise of the pathologist, while the accuracy of culture can depend on the conditions in which the specimen is transported and processed. When performed under optimal conditions, both techniques give very good results. The PCR test has similar sensitivity and specificity to histological and culture tests but a strict protocol must be followed to avoid contamination with H. pylori DNA. The rapid urease test (with a reading taken 1 hour later) is suitable for diagnosis before treatment but its sensitivity decreases after treatment. Smear examination has limited sensitivity. The urea breath test and serology (specific IgG detected by enzyme-linked immunosorbent assay with purified antigens) have sensitivities close to those using the best of the biopsy methods. Other points to consider when selecting a test are its availability, the rapidity of the results (which can range from a few minutes to 2 weeks), possibilities for retrospective analysis, quantification and the detection of pathogenic properties, the globality of certain tests that present an overall picture of the stomach, thus avoiding errors in sampling, and the cost of the test. Important added value can be gained from certain tests: histology allows evaluation of the status of the mucosa, culture allows strain typing and tests for antibiotic susceptibility, and the breath test can confirm successful eradication without endoscopy. When the diagnostic tests are performed correctly, most of them are highly accurate.

  14. Application of Bayesian Methods for Detecting Fraudulent Behavior on Tests

    Science.gov (United States)

    Sinharay, Sandip

    2018-01-01

    Producers and consumers of test scores are increasingly concerned about fraudulent behavior before and during the test. There exist several statistical or psychometric methods for detecting fraudulent behavior on tests. This paper provides a review of the Bayesian approaches among them. Four hitherto-unpublished real data examples are provided to…

  15. Detection of thrombocytic antibodies with the direct and indirect haemolysis inhibition test and the radioimmuno-Coombs test

    International Nuclear Information System (INIS)

    Mettenboerger, D.; Vith, E.

    1982-01-01

    Methods of application of the direct and indirect haemolysis inhibition test were studied in order to optimise the test parameters: The ultimate aim was to standardize the test method and compare its sensitivity in detecting various platelet antibodies with platelet indirect radioactive Coombs-test and the platelet immunofluorescence test. (orig.) [de

  16. An Optical Test Strip for the Detection of Benzoic Acid in Food

    Directory of Open Access Journals (Sweden)

    Fatimah Abu Bakar

    2011-07-01

    Full Text Available Fabrication of a test strip for detection of benzoic acid was successfully implemented by immobilizing tyrosinase, phenol and 3-methyl-2-benzothiazolinone hydrazone (MBTH onto filter paper using polystyrene as polymeric support. The sensing scheme was based on the decreasing intensity of the maroon colour of the test strip when introduced into benzoic acid solution. The test strip was characterized using optical fiber reflectance and has maximum reflectance at 375 nm. It has shown a highly reproducible measurement of benzoic acid with a calculated RSD of 0.47% (n = 10. The detection was optimized at pH 7. A linear response of the biosensor was obtained in 100 to 700 ppm of benzoic acid with a detection limit (LOD of 73.6 ppm. At 1:1 ratio of benzoic acid to interfering substances, the main interfering substance is boric acid. The kinetic analyses show that, the inhibition of benzoic is competitive inhibitor and the inhibition constant (Ki is 52.9 ppm. The activity of immobilized tyrosinase, phenol, and MBTH in the test strip was fairly sustained during 20 days when stored at 3 °C. The developed test strip was used for detection of benzoic acid in food samples and was observed to have comparable results to the HPLC method, hence the developed test strip can be used as an alternative to HPLC in detecting benzoic acid in food products.

  17. Optical generation,detection and non-destructive testing applications of terahertz waves

    Institute of Scientific and Technical Information of China (English)

    ZHANG; Weili; LIANG; Dachuan; TIAN; Zhen; HAN; Jiaguang; GU; Jianqiang; HE; Mingxia; OUYANG; Chunmei

    2016-01-01

    Optoelectronic terahertz generation and detection play a key role in the applications of non-destructive testing,which involves different areas such as physics,biological,material science,imaging,explosions detection,astronomy applications,semiconductor technology and superconductiong electronics. In this article,we present a reviewof the principle and performance of typical terahertz sources,detectors and non-destructive testing applications. On this basis,the newdevelopment and trends of terahertz radiation detectors are also discussed.

  18. [Rapid test for detection of susceptibility to cefotaxime in Enterobacteriaceae].

    Science.gov (United States)

    Jiménez-Guerra, Gemma; Hoyos-Mallecot, Yannik; Rodríguez-Granger, Javier; Navarro-Marí, José María; Gutiérrez-Fernández, José

    In this work an "in house" rapid test based on the change in pH that is due to hydrolysis for detecting Enterobacteriaceae susceptible to cefotaxime is evaluated. The strains of Enterobacteriaceae from 1947 urine cultures were assessed using MicroScan panels and the "in house" test. This rapid test includes red phenol solution and cefotaxime. Using MicroScan panels, 499 Enterobacteriaceae isolates were evaluated, which included 27 isolates of Escherichia coli producing extended-spectrum beta-lactamases (ESBL), 16 isolates of Klebsiella pneumoniae ESBL and 1 isolate of Klebsiella oxytoca ESBL. The "in house" test offers the following values: sensitivity 98% and specificity 97%, with negative predictive value 100% and positive predictive value 78%. The "in house" test based on the change of pH is useful in our area for detecting presumptively cefotaxime-resistant Enterobacteriaceae strains. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. 9 CFR 113.36 - Detection of pathogens by the chicken inoculation test.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of pathogens by the chicken... REQUIREMENTS Standard Procedures § 113.36 Detection of pathogens by the chicken inoculation test. The test for...,000 doses. (b) At least 25 healthy susceptible young chickens, properly identified and obtained from...

  20. The role of hazard- and risk-based approaches in ensuring food safety

    OpenAIRE

    Barlow, Susan M.; Boobis, Alan R.; Bridges, Jim; Cockburn, Andrew; Dekant, Wolfgang; Hepburn, Paul; Houben, Geert F.; König, Jürgen; Nauta, Maarten; Schuermans, Jeroen; Bánáti, Diána

    2015-01-01

    BackgroundFood legislation in the European Union and elsewhere includes both hazard- and risk-based approaches for ensuring safety. In hazard-based approaches, simply the presence of a potentially harmful agent at a detectable level in food is used as a basis for legislation and/or risk management action. Risk-based approaches allow consideration of exposure in assessing whether there may be unacceptable risks to health.Scope and approachThe advantages and disadvantages of hazard- and risk-ba...

  1. Explosive simulants for testing explosive detection systems

    Science.gov (United States)

    Kury, John W.; Anderson, Brian L.

    1999-09-28

    Explosives simulants that include non-explosive components are disclosed that facilitate testing of equipment designed to remotely detect explosives. The simulants are non-explosive, non-hazardous materials that can be safely handled without any significant precautions. The simulants imitate real explosives in terms of mass density, effective atomic number, x-ray transmission properties, and physical form, including moldable plastics and emulsions/gels.

  2. Modelling the System of Ensuring the Investment Security

    Directory of Open Access Journals (Sweden)

    Moroz Maxim O.

    2017-11-01

    Full Text Available The article explores approaches to modelling the system of ensuring the investment security. Necessity of observance of investment security of Ukraine has been substantiated. The author’s own vision of the modelling essentials has been provided. The eligibility for consideration of the system of ensuring the investment security of Ukraine in the functional, structural, process, formative, and factor aspects has been proved. The target setting and tasks of a functional model of the system of ensuring the investment security have been defined. The functions, subjects, organizational-economic mechanisms of the system of ensuring the investment security of Ukraine have been characterized. A structural model of the system of ensuring the investment security has been presented. Special attention has been given to the definition of objects of direct and indirect influence, control and controlled subsystems, aggregate of indicators, safe levels, principles of formation of the investment security system. The process and formative models of the system of ensuring the investment security, as well as the algorithm of the complex assessment of the level of investment security, were analyzed in detail. Measures to ensure the investment security of Ukraine have been defined.

  3. Minimum detection efficiencies for a loophole-free observable-asymmetric Bell-type test

    International Nuclear Information System (INIS)

    Garbarino, G.

    2010-01-01

    We discuss the problem of finding the most favorable conditions for closing the detection loophole in a test of local realism with a Bell inequality. For a generic nonmaximally entangled two-qubit state and two incompatible bases to be adopted for alternative measurements of two observables a and b on each party, we apply Hardy's proof of nonlocality without inequality and derive an Eberhard-like inequality. For an infinity of nonmaximally entangled states we find that it is possible to refute local realism by requiring perfect detection efficiency for only one of the two observables, say b, to be measured on each party: The test is free from the detection loophole for any value of the detection efficiency corresponding to the other observable a. The maximum tolerable noise in such a loophole-free observable-asymmetric test is also evaluated.

  4. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices.

    Science.gov (United States)

    Kraft, Marc

    2008-09-03

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.

  5. Ensuring Positiveness of the Scaled Difference Chi-square Test Statistic.

    Science.gov (United States)

    Satorra, Albert; Bentler, Peter M

    2010-06-01

    A scaled difference test statistic [Formula: see text] that can be computed from standard software of structural equation models (SEM) by hand calculations was proposed in Satorra and Bentler (2001). The statistic [Formula: see text] is asymptotically equivalent to the scaled difference test statistic T̄(d) introduced in Satorra (2000), which requires more involved computations beyond standard output of SEM software. The test statistic [Formula: see text] has been widely used in practice, but in some applications it is negative due to negativity of its associated scaling correction. Using the implicit function theorem, this note develops an improved scaling correction leading to a new scaled difference statistic T̄(d) that avoids negative chi-square values.

  6. Orthogonal series generalized likelihood ratio test for failure detection and isolation. [for aircraft control

    Science.gov (United States)

    Hall, Steven R.; Walker, Bruce K.

    1990-01-01

    A new failure detection and isolation algorithm for linear dynamic systems is presented. This algorithm, the Orthogonal Series Generalized Likelihood Ratio (OSGLR) test, is based on the assumption that the failure modes of interest can be represented by truncated series expansions. This assumption leads to a failure detection algorithm with several desirable properties. Computer simulation results are presented for the detection of the failures of actuators and sensors of a C-130 aircraft. The results show that the OSGLR test generally performs as well as the GLR test in terms of time to detect a failure and is more robust to failure mode uncertainty. However, the OSGLR test is also somewhat more sensitive to modeling errors than the GLR test.

  7. Detection Test for Leakage of CO{sub 2} into Sodium Loop

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sun Hee; Wi, Myung-Hwan; Min, Jae Hong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    This report is about the facility for the detection test for leakage of CO{sub 2} into sodium loop. The facility for the detection test for leakage of CO{sub 2} into sodium loop was introduced. The test will be carried out. Our experimental results are going to be expected to be used for approach methods to detect CO{sub 2} leaking into sodium in heat exchangers. A sodium-and-carbon dioxide (Na-CO{sub 2}) heat exchanger is one of the key components for the supercritical CO{sub 2} Brayton cycle power conversion system of sodium-cooled fast reactors (SFRs). A printed circuit heat exchanger (PCHE) is considered for the Na-CO{sub 2} heat exchanger, which is known to have potential for reducing the volume occupied by the exchangers compared to traditional shell-and-tube heat exchangers. Among various issues about the Na- CO{sub 2} exchanger, detection of CO{sub 2} leaking into sodium in the heat exchanger is most important thing for its safe operation. It is known that reaction products from sodium and CO{sub 2} such as sodium carbonate (Na{sub 2}CO{sub 3}) and amorphous carbon are hardly soluble in sodium, which cause plug sodium channels. Detection technique for Na{sub 2}CO{sub 3} in sodium loop has not been developed yet. Therefore, detection of CO{sub 2} and CO from reaction of sodium and CO{sub 2} are proper to detect CO{sub 2} leakage into sodium loop.

  8. Comparison of four urease-dependent tests of detecting HP infection

    International Nuclear Information System (INIS)

    Han Yuan; Huang Gang; Zhu Cuiying; Ling Liqun

    2001-01-01

    Objective: The aim of this study is to compare the four urease-dependent tests of detecting Hp infection. The authors used following method: 1) rapid urease test (RUT), 2) 14 C urea breath test ( 14 C-UBT), 3) 13 C urea breath test which is measured by with infrared spectrometry ( 13 C-UBT1), 4) 13 C urea breath test with mass spectrometry ( 13 C-UBT). Methods: 54 patients underwent RUT, 14 C-UBT, 13 C-UBT1, 13 C-UBT2 respectively. Results: Sensitivity and specificity, accurate rate, positive predictive value (PPV), negative predictive value (NPV), respectively, were as follows: RUT (82.1%, 80%, 81.5%, 91.4%, 63.2%), 14 C-UBT (97.4%, 100%, 98.1%, 100%, 93.8%), 13 C-UBT1 (100%, 93.3%, 98.1%, 97.5%, 100%), 13 C-UBT2 (100%, 86.7%, 96.3%, 95.1%, 100%), PPV of four tests are not significantly different (P>0.05). Conclusion: Four urease-dependent tests are high sensitive and accurate methods for detecting Hp infection. UBT is an ideal tool for diagnosis, screen and follow-up of Hp infection

  9. Specialists meeting on leak detection and location in LMFBR steam generators. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-10-01

    The following topics covered at the meeting were: with leak detection and location methods and equipment, including concentration measurements, helium tests, and electromagnetic methods; acoustic leak detection and related equipment; techniques and experiences in ensuring and measuring steam generator tightness during manufacturing, installation and repair, tube inspection methods for periodic control and damage assessment following leaks, influence of these methods on design of steam generators for LMFBR type reactors.

  10. Specialists meeting on leak detection and location in LMFBR steam generators. Summary report

    International Nuclear Information System (INIS)

    1978-10-01

    The following topics covered at the meeting were: with leak detection and location methods and equipment, including concentration measurements, helium tests, and electromagnetic methods; acoustic leak detection and related equipment; techniques and experiences in ensuring and measuring steam generator tightness during manufacturing, installation and repair, tube inspection methods for periodic control and damage assessment following leaks, influence of these methods on design of steam generators for LMFBR type reactors

  11. Executive cognitive impairment detected by simple bedside testing ...

    African Journals Online (AJOL)

    Aims. Cognitive impairment in people with type 2 diabetes is a barrier to successful disease management. We sought to determine whether impaired executive function as detected by a battery of simple bedside cognitive tests of executive function was associated with inadequate glycaemic control. Methods. People with ...

  12. Experimental study on flaw detectability of remote field eddy current testing

    International Nuclear Information System (INIS)

    Kamimura, T.; Fukui, S.; Iwahashi, Y.; Yamada, H.

    1988-01-01

    For the purpose of comprehending the effect in practical use of the remote field eddy current (RFEC) testing that becomes noticeable for the ISI technique of steel tubes, its flaw detectability was clarified through a model test. This study used straight and bending tubes of 3.8 mm in wall thickness and 31.8 mm in outside diameter. These tubes were inspected from their inside. After relations among the pickup coil output, coil distance, testing frequency, etc. were measured, a probe of the practical use type was manufactured to investigate its flaw detectability by means of simulated flaws. The authors discuss how it has been found that light local wall thinning on the outside surfaces can be detected by this technique and its effect in practical use can be expected with small influences due to magnetic permeability variations of tube materials, bending of tubes, etc

  13. Ensuring the Validity of the Micro Foundation in DSGE Models

    DEFF Research Database (Denmark)

    Andreasen, Martin Møller

    & Primiceri (American Economic Review, forth- coming) and Fernández-Villaverde & Rubio-Ramírez (Review of Economic Studies, 2007) do not satisfy these sufficient conditions, or any other known set of conditions ensuring finite values for the objective functions. Thus, the validity of the micro foundation......The presence of i) stochastic trends, ii) deterministic trends, and/or iii) stochastic volatil- ity in DSGE models may imply that the agents' objective functions attain infinite values. We say that such models do not have a valid micro foundation. The paper derives sufficient condi- tions which...... ensure that the objective functions of the households and the firms are finite even when various trends and stochastic volatility are included in a standard DSGE model. Based on these conditions we test the validity of the micro foundation in six DSGE models from the literature. The models of Justiniano...

  14. Summary of accidental releases of radioactivity detected off the Nevada Test Site, 1963--1986

    International Nuclear Information System (INIS)

    Patzer, R.G.; Phillips, W.G.; Grossman, R.F.; Black, S.C.; Costa, C.F.

    1988-08-01

    Of the more than 450 underground nuclear explosives tests conducted at the Nevada Test Site from August 1963 (signing of the Limited Test Ban Treaty) through the end of 1986, only 23 accidentally released radioactivity that was detectable beyond the boundary of the NTS. Of these 23, 4 were detectable off the NTS only by aircraft while the remainder were detectable by ground monitoring instruments. Since the Baneberry venting of December 1970, only two tests released radioactivity that was detectable off the NTS, and this was a seepage of radioactive noble gases. None of these releases from underground tests designed for complete containment caused exposure of the population living in the area that exceeded standards recommended by national and international radiation protection agencies. This report summarizes the releases from each of the tests, describes the monitoring that was conducted, and lists the location of the maximum exposure

  15. The use of serological tests in combination with the intradermal tuberculin test maximizes the detection of tuberculosis infected goats.

    Science.gov (United States)

    Bezos, Javier; Roy, Álvaro; Infantes-Lorenzo, José Antonio; González, Isabel; Venteo, Ángel; Romero, Beatriz; Grau, Anna; Mínguez, Olga; Domínguez, Lucas; de Juan, Lucía

    2018-05-01

    The diagnosis of tuberculosis (TB) in goats is based mainly on the single and comparative intradermal tuberculin (SIT and CIT) tests and, exceptionally, on the interferon-gamma (IFN-γ) assay, however they are not perfect in terms of sensitivity and specificity. Nevertheless, various serological assays that provide a potential cost-effective approach for the control of TB are also available or under development, and a variety of results have been reported regarding the ability of these tests to detect infected animals, particularly in the early stages of infection. In the present study, SIT/CIT and IFN-γ tests and three different serological assays were evaluated during two consecutive herd testing events in a recently infected caprine herd (n = 447) with a high prevalence of infection in order to evaluate their performance and provide field data with which to improve the TB control programs in this species. The proportion of infected animals that tested positive among all the infected goats (T+/I+ value) in the last herd testing event ranged from 26.2% (IC95%; 19.3-34.5) to 85.7% (IC95%; 78.5-90.7) using cell-based diagnostic tests. The SIT/SCIT tests detected more infected goats than the IFN-γ test, regardless of the interpretation criteria. The T+/I+ value of serology was 83.2 (IC95%; 75.2-89), although it increased significantly (P test (100%, IC95%; 97-100). In general, a parallel interpretation of intradermal tests with serology maximized the detection of infected goats. These results demonstrate that serological tests are valuable diagnostic tools to maximize the detection of TB infected goats, even in recent outbreaks, accelerating the eradication process. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Field Test Data for Detecting Vibrations of a Building Using High-Speed Video Cameras

    Science.gov (United States)

    2017-10-01

    ARL-TR-8185 ● OCT 2017 US Army Research Laboratory Field Test Data for Detecting Vibrations of a Building Using High-Speed Video...Field Test Data for Detecting Vibrations of a Building Using High-Speed Video Cameras by Caitlin P Conn and Geoffrey H Goldman Sensors and...June 2016 – October 2017 4. TITLE AND SUBTITLE Field Test Data for Detecting Vibrations of a Building Using High-Speed Video Cameras 5a. CONTRACT

  17. Efficacy of immunoassay chromatography test for hepatitis-C antibodies detection

    International Nuclear Information System (INIS)

    Batool, A.; Khan, M.I.; Bano, K.A.

    2009-01-01

    To asses the efficacy of commercially available tests device method for anti HCV detection. Methods: Total 2000 blood samples for detection of anti HCV were screened initially by immuno chromatographic method. Those found positive on initial screening were re-tested by ELISA method at the Biochemistry Laboratory of the Pakistan Medical Research Council, Fatima Jinnah Medical College, Lahore. Results: Out of a total of 2,000 blood samples, 177 were found to be initially reactive/positive for anti-HCV with immuno chromatographic method. When these reactive/positive samples were retested for confirmation with ELISA, 47 blood samples were found to have tested falsely positive for anti-HCV. Overall 2.35% of blood samples were found to be tested false positive for anti-HCV by immuno chromatographic device method. Conclusions: Immuno chromatographic device method test is rapid and simple, which can be used in setting with limited facility when rapid testing is required. However it should not be used as sole criteria for diagnosis but should serve the purpose of initial screening only. Further research is required to establish the reliability of such devices for their specificity and sensitivity. (author)

  18. Defect detectability of eddy current testing for underwater laser beam welding

    International Nuclear Information System (INIS)

    Ueno, Souichi; Kobayashi, Noriyasu; Ochiai, Makoto; Kasuya, Takashi; Yuguchi, Yasuhiro

    2011-01-01

    We clarified defect detectability of eddy current testing (ECT) as a surface inspection technique for underwater laser beam welding works of dissimilar metal welding (DMW) of reactor vessel nozzle. The underwater laser beam welding procedure includes groove caving as a preparation, laser beam welding in the grooves and welded surface grinding as a post treatment. Therefore groove and welded surface inspections are required in the underwater condition. The ECT is a major candidate as this inspection technique because a penetrant testing is difficult to perform in the underwater condition. Several kinds of experiments were curried out using a cross coil an ECT probe and ECT data acquisition system in order to demonstrate the ECT defect detectability. We used specimens, simulating groove and DMW materials at an RV nozzle, with electro-discharge machining (EDM) slits over it. Additionally, we performed a detection test for artificial stress corrosion cracking (SCC) defects. From these experimental results, we confirmed that an ECT was possible to detect EDM slits 0.3 mm or more in depth and artificial SCC defects 0.02 mm to 0.48 mm in depth on machined surface. Furthermore, the underwater ECT defect detectability is equivalent to that in air. We clarified an ECT is sufficiently usable as a surface inspection technique for underwater laser beam welding works. (author)

  19. Statistical Methods for the detection of answer copying on achievement tests

    NARCIS (Netherlands)

    Sotaridona, Leonardo

    2003-01-01

    This thesis contains a collection of studies where statistical methods for the detection of answer copying on achievement tests in multiple-choice format are proposed and investigated. Although all methods are suited to detect answer copying, each method is designed to address specific

  20. Ensuring the operational safety of nuclear power plants with WWER reactors

    International Nuclear Information System (INIS)

    Shasharin, G.A.; Veretennikov, G.A.; Abagyan, A.A.; Lesnoj, S.A.

    1984-01-01

    At the start of 1983, 27 nuclear power producing units with reactor facilities of the WWER type were in operation in the Soviet Union and other countries. In 1982 the average load factor for nuclear power plants with WWER reactors was 73 per cent. There was not a single nuclear accident or even damage with any significant radiation consequences in the WWER reactors during the entire period of their operation. The most modern nuclear power plants with WWER-440 and WWER-1000 reactors meet all present-day international requirements. Safe operation of the plants is achieved by a variety of measures, the most important of which include: procedures for increasing the reliability of plant equipment and systems; ensuring exact compliance with plant operating instructions; ensuring reliable operation of plant safety systems; action directed towards maintaining the skills of plant personnel at a level adequate to ensure the taking of proper action during transient processes and accident situations. The paper discusses concrete steps for ensuring safe nuclear power plant operation along these lines. In particular, measures such as the following are described: the use of a system for collecting and processing information on equipment failures and defects; the development and introduction of methods of early defect diagnosis; the performance of complex testing of safety systems; the training of highly skilled personnel for nuclear power plants at educational combines and at teaching and training centres making use of simulators; arranging accident-prevention training and special instruction for personnel. (author)

  1. Performance test of SKIROC II ASIC chip for the radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Jun, W. J.; Namgoong, H.; Kim, B. K.; Song, H. S.; Kim, H. S.; Lee, S. H.; Choi, H. J.; Ghergherehchi, M.; Chai, J. S. [Sungkyunkwan University, Suwon (Korea, Republic of)

    2017-04-15

    There is a PCB board called FEV8 board which can readout analog signal from any energy source, and amplify it for signal processing. For precise detection, the board had been designed to operate in wide range of energy condition, with high-resolutive detection performance. This function has the possibility of the utilization for the radiation detection. The channels of the prototype board must be evaluated to make sure that the board is perfect or not. This research had made an progress for the radiation detection as well as the electronics of the intricate combination of the measurement instrumentations. The number of the noisy channels had been measured for threshold scan, and every channels in the board had been evaluated. By improving the experimental conditions such as test script in Linux system or well designed ground condition of the test bench, much more clean data will be able to be acquisited.

  2. Early fault detection using design models for collision prevention in medical equipment

    NARCIS (Netherlands)

    Mooij, A.J.; Hooman, J.; Albers, R.

    2013-01-01

    In the medical domain there is a tension between the requested speed of innovation and the time needed to deliver a certifiable system. To ensure the required safety, usually a long test and integration phase is needed. To shorten this phase and to avoid late bug fixing, the aim is to detect faults

  3. Towards ensuring gender equity.

    Science.gov (United States)

    Basu, A

    1996-01-01

    All people should participate in the development process. Many, however, remain excluded from the benefits of development. For example, women are privy to only a small share of developmental opportunities. The goals of equality, development, and peace were stated during the Fourth World Conference on Women held in Beijing in September 1995. The author considers whether women truly have equitable access to literacy, education, food, nutrition, health, employment, and the political and economic decision making process. She stresses that the goals pronounced at the Fourth World Conference on Women must be backed up with the necessary resources, including institutions established at the local, state, and national levels to ensure that the objectives are implemented and the implementation is monitored. The author further argues that in order for women to achieve equality with men, all girls must have access to primary and secondary schools; basic literacy is inadequate. Moreover, gender stereotyping must be avoided and gender sensitization ensured at all levels.

  4. Effect of ensure on the oral bioavailability of gatifloxacin in healthy volunteers.

    Science.gov (United States)

    Kays, Michael B; Overholser, Brian R; Lagvankar, Seema; Goldman, Mitchell; Sowinski, Kevin M

    2005-11-01

    To determine the effect of Ensure on the relative oral bioavailability of gatifloxacin in healthy volunteers. Single-dose, randomized, crossover study. University-affiliated research center. Twelve healthy volunteers (six men, six women) aged 18 years or older with no clinically significant abnormal findings on physical examination or in medical history. Intervention. Subjects consumed 120 ml of study liquid-water or Ensure-every 30 minutes for five doses. With the second dose, subjects ingested a single gatifloxacin 400-mg tablet that had been uniformly crushed and mixed into the study liquid. Serial blood samples were collected for 48 hours, and gatifloxacin concentrations were determined by high-performance liquid chromatography. Pharmacokinetic data were analyzed by using noncompartmental methods. Maximum serum concentration (Cmax) and area under the serum concentration-time curve from zero to infinity (AUC0-infinity) were tested for bioequivalence after log-transformation of the data. Comparison of parameters for gatifloxacin administered with water versus those with Ensure showed that Cmax (4.35 +/- 0.90 vs 2.41 +/- 0.58 mug/ml, pinfinity) (42.4 +/- 10.1 vs 31.3 +/- 8.3 mg*hr/L, pinfinity. The median time to reach Cmax was significantly prolonged when gatifloxacin was administered with Ensure versus that with water (2.5 hrs vs 1.0 hr, p=0.006). The Cmax and AUC0-infinity of gatifloxacin were significantly decreased when the drug was administered with Ensure. The clinical significance of these findings will depend on the offending pathogen and its susceptibility to gatifloxacin.

  5. A NOTE ON THE CONVENTIONAL OUTLIER DETECTION TEST PROCEDURES

    Directory of Open Access Journals (Sweden)

    JIANFENG GUO

    Full Text Available Under the assumption of that the variance-covariance matrix is fully populated, Baarda's w-test is turn out to be completely different from the standardized least-squares residual. Unfortunately, this is not generally recognized. In the limiting case of only one degree of freedom, all the three types of test statistics, including Gaussian normal test, Student's t-test and Pope's Tau-test, will be invalid for identification of outliers: (1 all the squares of the Gaussian normal test statistic coincide with the goodness-of-fit (global test statistic, even for correlated observations. Hence, the failure of the global test implies that all the observations will be flagged as outliers, and thus the Gaussian normal test is inconclusive for localization of outliers; (2 the absolute values of the Tau-test statistic are all exactly equal to one, no matter whether the observations are contaminated. Therefore, the Tau-test cannot work for outlier detection in this situation; and (3 Student's t-test statistics are undefined.

  6. PageFocus: Using paradata to detect and prevent cheating on online achievement tests.

    Science.gov (United States)

    Diedenhofen, Birk; Musch, Jochen

    2017-08-01

    Cheating threatens the validity of unproctored online achievement tests. To address this problem, we developed PageFocus, a JavaScript that detects when participants abandon test pages by switching to another window or browser tab. In a first study, we aimed at testing whether PageFocus could detect and prevent cheating. We asked 115 lab and 186 online participants to complete a knowledge test comprising items that were difficult to answer but easy to look up on the Internet. Half of the participants were invited to look up the solutions, which significantly increased their test scores. The PageFocus script detected test takers who abandoned the test page with very high sensitivity and specificity, and successfully reduced cheating by generating a popup message that asked participants not to cheat. In a second study, 510 online participants completed a knowledge test comprising items that could easily be looked up and a reasoning task involving matrices that were impossible to look up. In a first group, a performance-related monetary reward was promised to the top scorers; in a second group, participants took part in a lottery that provided performance-unrelated rewards; and in a third group, no incentive was offered. PageFocus revealed that participants cheated more when performance-related incentives were offered. As expected, however, this effect was limited to items that could easily be looked up. We recommend that PageFocus be routinely employed to detect and prevent cheating on online achievement tests.

  7. The White test: a new dye test for intraoperative detection of bile leakage during major liver resection.

    Science.gov (United States)

    Nadalin, Silvio; Li, Jun; Lang, Hauke; Sotiropoulos, Georgios C; Schaffer, Randolph; Radtke, Arnold; Saner, Fuat; Broelsch, Christoph E; Malagó, Massimo

    2008-04-01

    To describe a new intraoperative bile leakage test in patients undergoing a major liver resection aimed to combine the advantages of each of the other standard bile leakage tests (accurate visualization of leaks, reproducibility, and ease of use) without their disadvantages. At the end of the major hepatic resection, 10 to 30 mL of sterile fat emulsion, 5%, is injected via an olive-tip cannula through the cystic duct while manually occluding the distal common bile duct. As the biliary tree fills with fat emulsion solution, leakage of the white fluid is visualized on the raw surface of the liver resection margin. The detected leakages are closed by means of single stitches. Afterwards, the residual fat emulsion on the resection surface is washed off with saline and the White test is repeated to detect and/or exclude additional bile leakages. At the end, residual fat emulsion is washed out from the biliary tract by a low-pressure infusion of saline solution. Intraoperatively, additional potential bile leakages (not seen using a conventional saline bile leakage test) were identified in 74% of our patients. Postoperative bile leakages (within 30 days) occurred in only 5.1% of patients when the White test was used. No adverse effects related to this technique were observed. The White test has clear advantages in comparison with other bile leakage tests: it precisely detects bile leakages, regardless of size; it does not stain the resection surface, allowing it to be washed off and repeated ad infinitum; and it is safe, quick, and inexpensive.

  8. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  9. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  10. HIV testing and counseling: test providers' experiences of best practices.

    Science.gov (United States)

    Myers, Ted; Worthington, Catherine; Haubrich, Dennis J; Ryder, Karen; Calzavara, Liviana

    2003-08-01

    Although education is central to HIV testing and counseling, little is known about the educational processes within the testing experience. This study investigated test providers' understandings of testing and counseling best practices. Interviews with a purposive sample of 24 test providers were thematically analyzed. Analysis revealed five best practices specific to HIV education and public health--ensuring information and education for HIV risk reduction, individualization of risk assessment, ensuring test results are given in person, providing information and referrals, and facilitating partner notification--and six practices not specific to HIV counseling relationship building. The latter were building trust and rapport; maintaining professional boundaries; ensuring a comfortable, safe environment; ensuring confidentiality; imparting nonjudgmntal attitude; and self-determination. The identified best practices demonstrated remarkable consistency across respondent subgroups. Although counseling was seen as largely educational and with a preventive focus, it included individualized messages based on assessments of risk, knowledge, and social and cultural characteristics.

  11. Design and preliminary test results of the quench detection system for IFSMTF

    International Nuclear Information System (INIS)

    Shen, S.S.; Walstrom, P.L.; Wilson, C.T.; Goddard, J.S.

    1985-01-01

    A unique quench detection system was designed for the International Fusion Superconducting Magnet Test Facility (IFSMTF), where a simultaneous test of six large superconducting toroidal field magnets will be carried out. The scheme was based on analog subtraction of self and neighboring pickup winding voltage from the coil voltage to yield a compensated signal proportional to a normal-zone voltage. The compensated signals were input to quench detection modules that give a quench output signal to discharge the coil if the compensated signals exceed preset thresholds for preset time durations. This paper summarizes the design and analysis of the system and presents the experimental results of the simulation tests, two-coil charging-discharging tests, and the normal-zone recovery tests

  12. ESBL Detection: Comparison of a Commercially Available Chromogenic Test for Third Generation Cephalosporine Resistance and Automated Susceptibility Testing in Enterobactericeae.

    Directory of Open Access Journals (Sweden)

    Mohamed Ramadan El-Jade

    Full Text Available Rapid detection and reporting of third generation cephalosporine resistance (3GC-R and of extended spectrum betalactamases in Enterobacteriaceae (ESBL-E is a diagnostic and therapeutic priority to avoid inefficacy of the initial antibiotic regimen. In this study we evaluated a commercially available chromogenic screen for 3GC-R as a predictive and/or confirmatory test for ESBL and AmpC activity in clinical and veterinary Enterobacteriaceae isolates. The test was highly reliable in the prediction of cefotaxime and cefpodoxime resistance, but there was no correlation with ceftazidime and piperacillin/tazobactam minimal inhibitory concentrations. All human and porcine ESBL-E tested were detected with exception of one genetically positive but phenotypically negative isolate. By contrast, AmpC detection rates lay below 30%. Notably, exclusion of piperacillin/tazobactam resistant, 3GC susceptible K1+ Klebsiella isolates increased the sensitivity and specificity of the test for ESBL detection. Our data further imply that in regions with low prevalence of AmpC and K1 positive E. coli strains chromogenic testing for 3GC-R can substitute for more time consuming ESBL confirmative testing in E. coli isolates tested positive by Phoenix or VITEK2 ESBL screen. We, therefore, suggest a diagnostic algorithm that distinguishes 3GC-R screening from primary culture and species-dependent confirmatory ESBL testing by βLACTATM and discuss the implications of MIC distribution results on the choice of antibiotic regimen.

  13. [Validation of three screening tests used for early detection of cervical cancer].

    Science.gov (United States)

    Rodriguez-Reyes, Esperanza Rosalba; Cerda-Flores, Ricardo M; Quiñones-Pérez, Juan M; Cortés-Gutiérrez, Elva I

    2008-01-01

    to evaluate the validity (sensitivity, specificity, and accuracy) of three screening methods used in the early detection of the cervical carcinoma versus the histopathology diagnosis. a selected sample of 107 women attended in the Opportune Detection of Cervicouterine Cancer Program in the Hospital de Zona 46, Instituto Mexicano del Seguro Social in Durango, during the 2003 was included. The application of Papa-nicolaou, acetic acid test, and molecular detection of human papillomavirus, and histopatholgy diagnosis were performed in all the patients at the time of the gynecological exam. The detection and tipification of the human papillomavirus was performed by polymerase chain reaction (PCR) and analysis of polymorphisms of length of restriction fragments (RFLP). Histopathology diagnosis was considered the gold standard. The evaluation of the validity was carried out by the Bayesian method for diagnosis test. the positive cases for acetic acid test, Papanicolaou, and PCR were 47, 22, and 19. The accuracy values were 0.70, 0.80 and 0.99, respectively. since the molecular method showed a greater validity in the early detection of the cervical carcinoma we considered of vital importance its implementation in suitable programs of Opportune Detection of Cervicouterino Cancer Program in Mexico. However, in order to validate this conclusion, cross-sectional studies in different region of country must be carried out.

  14. Sensitivity of the improved Dutch tube diffusion test for detection of ...

    African Journals Online (AJOL)

    The sensitivity of the improved two-tube test for detection of antimicrobial residues in Kenyan milk was investigated by comparison with the commercial Delvo test SP. Suspect positive milk samples (n =244) from five milk collection centers, were analyzed with the improved two-tube and the commercial Delvo SP test as per ...

  15. Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2015-01-01

    The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.

  16. 14C-urea breath test for the detection of Helicobacter pylori

    International Nuclear Information System (INIS)

    Veldhuyzen van Zanten, S.J.; Tytgat, K.M.; Hollingsworth, J.; Jalali, S.; Rshid, F.A.; Bowen, B.M.; Goldie, J.; Goodacre, R.L.; Riddell, R.H.; Hunt, R.H.

    1990-01-01

    The high urease activity of Helicobacter pylori can be used to detect this bacterium by noninvasive breath tests. We have developed a 14 C-urea breath test which uses 5 microCi 14 C with 50 mg nonradioactive urea. Breath samples are collected at baseline and every 30 min for 2 h. Our study compared the outcome of the breath test to the results of histology and culture of endoscopically obtained gastric biopsies in 84 patients. The breath test discriminated well between the 50 positive patients and the 34 patients negative for Helicobacter pylori: the calculated sensitivity was 100%, specificity 88%, positive predictive value 93%, and negative predictive value 100%. Treatment with bismuth subsalicylate and/or ampicillin resulted in lower counts of exhaled 14 CO 2 which correlated with histological improvement in gastritis. The 14 C-urea breath test is a better gold standard for the detection of Helicobacter pylori than histology and/or culture

  17. Domestic Banks in Bangladesh Could Ensure Efficiency by Improving Human Resource Management Practices.

    Directory of Open Access Journals (Sweden)

    Abdul Kadar Muhammad Masum

    Full Text Available The paper aims to examine the influence of human resource management (HRM practices on bank efficiency using Malmquist index of total factor productivity. The model comprises HRM index that represents the quality of HRM practices. The results are decomposed into three efficiency scores, namely, technical efficiency, pure efficiency, and scale efficiency. In this study, panel data for 44 banks in Bangladesh are used for the period 2008-2013. This paper reveals that foreign banks are ahead in converting the influence of HRM practices into efficiency scores (0.946>0.833. On the other hand, domestic banks performed better than foreign banks in terms of pure efficiency and scale efficiency. But, in terms of technical efficiency, the domestic banks are regressed by 6.7% annually whereas foreign banks are progressed with a yearly value of 5.8%. The results are robust, because the Mann-Whitney test and Kruskall-Wallis test (non-parametric tests also confirm the same results. This study emphasizes HRM practices in the banking industry to ensure efficiency in the long-term scenario. Domestic banks are suggested to ensure continuous development in HRM practices in order to compete with foreign banks.

  18. Domestic Banks in Bangladesh Could Ensure Efficiency by Improving Human Resource Management Practices

    Science.gov (United States)

    Muhammad Masum, Abdul Kadar; Azad, Md. Abul Kalam; Hoque, Kazi Enamul; Beh, Loo-See

    2015-01-01

    The paper aims to examine the influence of human resource management (HRM) practices on bank efficiency using Malmquist index of total factor productivity. The model comprises HRM index that represents the quality of HRM practices. The results are decomposed into three efficiency scores, namely, technical efficiency, pure efficiency, and scale efficiency. In this study, panel data for 44 banks in Bangladesh are used for the period 2008-2013. This paper reveals that foreign banks are ahead in converting the influence of HRM practices into efficiency scores (0.946>0.833). On the other hand, domestic banks performed better than foreign banks in terms of pure efficiency and scale efficiency. But, in terms of technical efficiency, the domestic banks are regressed by 6.7% annually whereas foreign banks are progressed with a yearly value of 5.8%. The results are robust, because the Mann-Whitney test and Kruskall-Wallis test (non-parametric tests) also confirm the same results. This study emphasizes HRM practices in the banking industry to ensure efficiency in the long-term scenario. Domestic banks are suggested to ensure continuous development in HRM practices in order to compete with foreign banks. PMID:26221727

  19. Domestic Banks in Bangladesh Could Ensure Efficiency by Improving Human Resource Management Practices.

    Science.gov (United States)

    Masum, Abdul Kadar Muhammad; Azad, Md Abul Kalam; Hoque, Kazi Enamul; Beh, Loo-See

    2015-01-01

    The paper aims to examine the influence of human resource management (HRM) practices on bank efficiency using Malmquist index of total factor productivity. The model comprises HRM index that represents the quality of HRM practices. The results are decomposed into three efficiency scores, namely, technical efficiency, pure efficiency, and scale efficiency. In this study, panel data for 44 banks in Bangladesh are used for the period 2008-2013. This paper reveals that foreign banks are ahead in converting the influence of HRM practices into efficiency scores (0.946>0.833). On the other hand, domestic banks performed better than foreign banks in terms of pure efficiency and scale efficiency. But, in terms of technical efficiency, the domestic banks are regressed by 6.7% annually whereas foreign banks are progressed with a yearly value of 5.8%. The results are robust, because the Mann-Whitney test and Kruskall-Wallis test (non-parametric tests) also confirm the same results. This study emphasizes HRM practices in the banking industry to ensure efficiency in the long-term scenario. Domestic banks are suggested to ensure continuous development in HRM practices in order to compete with foreign banks.

  20. The Stool DNA Test is More Accurate than the Plasma Septin 9 Test in Detecting Colorectal Neoplasia

    Science.gov (United States)

    Ahlquist, David A.; Taylor, William R.; Mahoney, Douglas W.; Zou, Hongzhi; Domanico, Michael; Thibodeau, Stephen N.; Boardman, Lisa A.; Berger, Barry M.; Lidgard, Graham P.

    2014-01-01

    Background & Aims Several noninvasive tests have been developed for colorectal cancer (CRC) screening. We compared the sensitivities of a multi-marker test for stool DNA (sDNA) and a plasma test for methylated Septin 9 (SEPT9) in identifying patients with large adenomas or CRC. Methods We analyzed paired stool and plasma samples from 30 patients with CRC and 22 with large adenomas from Mayo Clinic archives. Stool (n=46) and plasma (n=49) samples from age- and sex-matched patients with normal colonoscopy results were used as controls. The sDNA test is an assay for methylated BMP3, NDRG4, vimentin, and TFPI2; mutant KRAS; the β-actin gene, and quantity of hemoglobin (by the porphyrin method). It was performed blindly at Exact Sciences (Madison WI); the test for SEPT9 was performed at ARUP Laboratories (Salt Lake City UT). Results were considered positive based on the manufacturer's specificity cutoff values of 90% and 89%, respectively. Results The sDNA test detected adenomas (median 2 cm, range 1–5 cm) with 82% sensitivity (95% confidence interval [CI], 60%–95%); SEPT9 had 14% sensitivity (95% CI, 3%–35%; P=.0001). The sDNA test identified patients with CRC with 87% sensitivity (95% CI, 69%–96%); SEPT9 had 60% sensitivity (95% CI, 41%–77%; P=.046). The sDNA test identified patients with stage I–III CRC with 91% sensitivity (95% CI, 71%–99%); SEPT9 had 50% sensitivity (95% CI, 28%–72%; P=.013); for stage IV CRC, sensitivity values were 75% (95% CI, 35%–97%) and 88% (95% CI, 47%–100%), respectively (P=.56). False-positive rates were 7% for the sDNA test and 27% for SEPT9. Conclusions Based on analyses of paired samples, the sDNA test detects non-metastatic CRC and large adenomas with significantly greater levels of sensitivity than the SEPT9 test. These findings might be used to modify approaches for CRC prevention and early detection. PMID:22019796

  1. Field-test of a date-rape drug detection device.

    Science.gov (United States)

    Quest, Dale W; Horsley, Joanne

    2007-01-01

    Drink Safe Technology Version 1.2 is an inexpensive color-change reagent test marketed internationally for use by consumers in settings such as a night club to detect potentially incapacitating concentrations of gamma-hydroxybutyric acid (GHB) and ketamine in beverages. The objective of this study was to compare product performance in the laboratory and performance in the hands of consumers in the field. Product performance in the laboratory adhered to the protocol defined by the manufacturer. Product performance in the hands of consumers in field settings allowed browsing participants to pipette an aliquot of their own drinks into randomly coded vials containing authentic drugs, or pure water, so as to yield the same concentrations of GHB or ketamine specified in the manufacturer-defined protocol, or blanks. Consumers were to proceed according to the directions printed on the product, and to record their results on a card with a code corresponding with the vial to which they had added an aliquot of their beverage. Diagnostic performance was calculated using two-way analysis. In the laboratory, Drink Safe Technology Version 1.2 reliably detected GHB and ketamine at concentrations specified by the manufacturer's protocol. The reactive color change denoting a positive test for GHB was rapid, but a positive test for ketamine required substantially more time to resolve. Nonetheless, test accuracy following the manufacturer's protocol in the laboratory was 100%. In the field, based on 101 paired-test results recorded by consumers, the test efficiency was 65.1%, sensitivity 50%, and specificity 91.6%. The product performed much better in the laboratory than it did in the hand of consumers in the field. There seems to be considerable potential for consumers to misinterpret a test result. The potential for consumers to record a false-negative test result for a spiked drink is cause for concern.

  2. Radioimmunoassay test system for detection of anti-insulin antibodies

    International Nuclear Information System (INIS)

    Dudko, N.V.; Piven', N.V.; Ibragimova, G.V.; Kasatkin, Yu.N.

    1995-01-01

    A radiodiagnostic test system has been developed and commercial kit for radioimmunoassay of anti-insulin antibodies in human blood serum created. Clinical trials of the kit in patients (150 diabetics with types 1 and 2 condition) and normal subjects (n=100) demonstrated the possibility of using this kit for the detection of preclinical forms of diabetes and for distinguishing groups at risk of diabetes among children and adults, for the detection of insulin resistance, for the differential diagnosis of diabetes, and for monitoring the efficacy of insulin therapy. 9 refs.; 1 tab

  3. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  4. Integration and road tests of a self-sensing CNT concrete pavement system for traffic detection

    Science.gov (United States)

    Han, Baoguo; Zhang, Kun; Burnham, Tom; Kwon, Eil; Yu, Xun

    2013-01-01

    In this paper, a self-sensing carbon nanotube (CNT) concrete pavement system for traffic detection is proposed and tested in a roadway. Pre-cast and cast-in-place self-sensing CNT concrete sensors were simultaneously integrated into a controlled pavement test section at the Minnesota Road Research Facility (MnROAD), USA. Road tests of the system were conducted by using an MnROAD five-axle semi-trailer tractor truck and a van, respectively, both in the winter and summer. Test results show that the proposed self-sensing pavement system can accurately detect the passing of different vehicles under different vehicular speeds and test environments. These findings indicate that the developed self-sensing CNT concrete pavement system can achieve real-time vehicle flow detection with a high detection rate and a low false-alarm rate.

  5. Integration and road tests of a self-sensing CNT concrete pavement system for traffic detection

    International Nuclear Information System (INIS)

    Han, Baoguo; Zhang, Kun; Yu, Xun; Burnham, Tom; Kwon, Eil

    2013-01-01

    In this paper, a self-sensing carbon nanotube (CNT) concrete pavement system for traffic detection is proposed and tested in a roadway. Pre-cast and cast-in-place self-sensing CNT concrete sensors were simultaneously integrated into a controlled pavement test section at the Minnesota Road Research Facility (MnROAD), USA. Road tests of the system were conducted by using an MnROAD five-axle semi-trailer tractor truck and a van, respectively, both in the winter and summer. Test results show that the proposed self-sensing pavement system can accurately detect the passing of different vehicles under different vehicular speeds and test environments. These findings indicate that the developed self-sensing CNT concrete pavement system can achieve real-time vehicle flow detection with a high detection rate and a low false-alarm rate. (paper)

  6. Viral RNA testing and automation on the bead-based CBNE detection microsystem.

    Energy Technology Data Exchange (ETDEWEB)

    Galambos, Paul C.; Bourdon, Christopher Jay; Farrell, Cara M.; Rossito, Paul (University of California at Davis); McClain, Jaime L.; Derzon, Mark Steven; Cullor, James Sterling (University of California at Davis); Rahimian, Kamayar

    2008-09-01

    We developed prototype chemistry for nucleic acid hybridization on our bead-based diagnostics platform and we established an automatable bead handling protocol capable of 50 part-per-billion (ppb) sensitivity. We are working towards a platform capable of parallel, rapid (10 minute), raw sample testing for orthogonal (in this case nucleic acid and immunoassays) identification of biological (and other) threats in a single sensor microsystem. In this LDRD we developed the nucleic acid chemistry required for nucleic acid hybridization. Our goal is to place a non-cell associated RNA virus (Bovine Viral Diarrhea, BVD) on the beads for raw sample testing. This key pre-requisite to showing orthogonality (nucleic acid measurements can be performed in parallel with immunoassay measurements). Orthogonal detection dramatically reduces false positives. We chose BVD because our collaborators (UC-Davis) can supply samples from persistently infected animals; and because proof-of-concept field testing can be performed with modification of the current technology platform at the UC Davis research station. Since BVD is a cattle-prone disease this research dovetails with earlier immunoassay work on Botulinum toxin simulant testing in raw milk samples. Demonstration of BVD RNA detection expands the repertoire of biological macromolecules that can be adapted to our bead-based detection. The resources of this late start LDRD were adequate to partially demonstrate the conjugation of the beads to the nucleic acids. It was never expected to be adequate for a full live virus test but to motivate that additional investment. In addition, we were able to reduce the LOD (Limit of Detection) for the botulinum toxin stimulant to 50 ppb from the earlier LOD of 1 ppm. A low LOD combined with orthogonal detection provides both low false negatives and low false positives. The logical follow-on steps to this LDRD research are to perform live virus identification as well as concurrent nucleic acid and

  7. Sensitivity of field tests, serological and molecular techniques for Plum Pox Virus detection in various tissues

    Directory of Open Access Journals (Sweden)

    Mojca VIRŠČEK MARN

    2015-12-01

    Full Text Available Sensitivity of field tests (AgriStrip  and Immunochromato, DAS-ELISA, two step RT-PCR and real-time RT-PCR for Plum pox virus (PPV detection was tested in various tissues of apricot, peach, plum and damson plum trees infected with isolates belonging to PPV-D, PPV-M or PPV-Rec, the three strains present in Slovenia. Flowers of apricot and plum in full bloom proved to be a very good source for detection of PPV. PPV could be detected with all tested techniques in symptomatic parts of leaves in May and with one exception even in the beginning of August, but it was not detected in asymptomatic leaves using field tests, DAS-ELISA and partly also molecular techniques. PPV was detected only in some of the samples of asymptomatic parts of the leaves with symptoms and of stalks by field tests and DAS-ELISA. Infections were not detected in buds in August using field tests or DAS-ELISA. Field tests are useful for confirmation of the PPV infection in symptomatic leaves, but in tissues without symptoms DAS-ELISA should be combined or replaced by molecular techniques.

  8. Labor security in radiation flaw detection

    International Nuclear Information System (INIS)

    Margulis, U.Ya.; Chistov, E.D.; Partolin, O.F.; Pertsov, V.A.; Momzhiev, B.N.; Sprygaev, I.F.

    1986-01-01

    Problems of ensuring safe labour conditions in radiation flaw detection are considered. Methods for ionizing radiation protection are given calculating techniques for shielding flaw detectors and stationary structures are presented as well. Safe methods of nondestructive testing of items under field conditions, in a shop and special laboratories using gamma- and X-ray flaw detectors, betatrons, electron accelerators are described. Attention is paid to the principles of radiation factor stantardization as well as radiation monitoring. Analysis of accidents and recommendations on their prevention and liquidation of accidental consequences are given

  9. ESSENCE OF THE PROBLEM OF ENSURING FOOD SECURITY

    OpenAIRE

    Lalayan G. G.

    2013-01-01

    In this article we have revealed the essence of the problem of ensuring food security in detail. The components of economic safety at macroeconomic level are described, defining conditions of ensuring national food security are shown

  10. Performance Test of BF3 Neutron Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yu Sun; Shin, Ho Cheol [KHNP-CRI, Daejeon (Korea, Republic of); Cho, Jin Bok; Oh, Sae Hyun; Ryou, Seok Jean [USERS, Daejeon (Korea, Republic of)

    2015-10-15

    The neutron detecting system of First-of-a-kind plant such an APR1400 at Shin Kori should have been verified in the condition of low operating temperature and pressure of the primary coolant system before receiving the operation license. Auxiliary Ex-core Neutron Flux Monitoring System (AENFMS) is supposed to be installed using BF3 neutron detector in Shin Kori plant. The performance test of AENFMS was conducted to measure neutron sensitivity, moderation ratio and count rate in the same condition with Ex-core Neutron Flux Monitoring System (ENFMS) of APR1400 to verify its detection characteristics in compliance with the functional requirement. Performance test has been conducted for AENFMS of APR1400 to verify BF3 neutron sensitivity, moderation ration of PE, expecting neutron signal count rate from AENFMS, possible extending cable length from detector to pre-amplifier. As a result of measurement, the neutron sensitivity of 34.246±0.168(95%CI)cps/nv, moderation ratio of 11.343±0.039(95%CI) and AENFMS expecting count rate related to ENFMS of 17.8 times are acceptable in compliance with functional requirement, respectively.

  11. Optical Production and Detection of Ultrasonic Waves in Metals for Nondestructive Testing

    Science.gov (United States)

    Morrison, R. A.

    1972-01-01

    Ultrasonic waves were produced by striking the surface of a metal with the focused one-joule pulse of a Q-switched ruby laser. Rayleigh (surface) waves and longitudinal waves were detected with conventional transducers. Optical methods of detection were tested and developed. Rayleigh waves were produced with an oscillator and transducer. They were optically detected on curved polished surfaces, and on unpolished surfaces. The technique uses a knife edge to detect small angle changes of the surface as the wave pulse passes the illuminated spot. Optical flaw detection using pulse echo and attenuation is demonstrated.

  12. KAtex antigen-detection test as a diagnostic tool for latent visceral ...

    African Journals Online (AJOL)

    SERVER

    2008-04-03

    Apr 3, 2008 ... Urine samples were tested by kAtex kit to detect VL antigen. All sera .... IFA, and ELISA-IgG and IgM) to finding of agreement and validity and reliability .... Animal inoculation is not usually employed as a diag- nostic test, since ...

  13. Spurious Seasonality Detection: A Non-Parametric Test Proposal

    Directory of Open Access Journals (Sweden)

    Aurelio F. Bariviera

    2018-01-01

    Full Text Available This paper offers a general and comprehensive definition of the day-of-the-week effect. Using symbolic dynamics, we develop a unique test based on ordinal patterns in order to detect it. This test uncovers the fact that the so-called “day-of-the-week” effect is partly an artifact of the hidden correlation structure of the data. We present simulations based on artificial time series as well. While time series generated with long memory are prone to exhibit daily seasonality, pure white noise signals exhibit no pattern preference. Since ours is a non-parametric test, it requires no assumptions about the distribution of returns, so that it could be a practical alternative to conventional econometric tests. We also made an exhaustive application of the here-proposed technique to 83 stock indexes around the world. Finally, the paper highlights the relevance of symbolic analysis in economic time series studies.

  14. Ensuring effective project management

    International Nuclear Information System (INIS)

    Ward, J.N.

    1980-01-01

    A brief description is given of the organisation methods employed by the Bechtel Power Corporation, in their contract with Mississippi Power and Light Company for the design, construction and procurement activities for the Grand Gulf Nuclear Station. The aim is to ensure effective management, and good communications at all stages of construction, between the project team and the client. (U.K.)

  15. Ensuring Software IP Cleanliness

    OpenAIRE

    Mahshad Koohgoli; Richard Mayer

    2007-01-01

    At many points in the life of a software enterprise, determination of intellectual property (IP) cleanliness becomes critical. The value of an enterprise that develops and sells software may depend on how clean the software is from the IP perspective. This article examines various methods of ensuring software IP cleanliness and discusses some of the benefits and shortcomings of current solutions.

  16. Validation of Metagenomic Next-Generation Sequencing Tests for Universal Pathogen Detection.

    Science.gov (United States)

    Schlaberg, Robert; Chiu, Charles Y; Miller, Steve; Procop, Gary W; Weinstock, George

    2017-06-01

    - Metagenomic sequencing can be used for detection of any pathogens using unbiased, shotgun next-generation sequencing (NGS), without the need for sequence-specific amplification. Proof-of-concept has been demonstrated in infectious disease outbreaks of unknown causes and in patients with suspected infections but negative results for conventional tests. Metagenomic NGS tests hold great promise to improve infectious disease diagnostics, especially in immunocompromised and critically ill patients. - To discuss challenges and provide example solutions for validating metagenomic pathogen detection tests in clinical laboratories. A summary of current regulatory requirements, largely based on prior guidance for NGS testing in constitutional genetics and oncology, is provided. - Examples from 2 separate validation studies are provided for steps from assay design, and validation of wet bench and bioinformatics protocols, to quality control and assurance. - Although laboratory and data analysis workflows are still complex, metagenomic NGS tests for infectious diseases are increasingly being validated in clinical laboratories. Many parallels exist to NGS tests in other fields. Nevertheless, specimen preparation, rapidly evolving data analysis algorithms, and incomplete reference sequence databases are idiosyncratic to the field of microbiology and often overlooked.

  17. A harmonic pulse testing method for leakage detection in deep subsurface storage formations

    Science.gov (United States)

    Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan

    2015-06-01

    Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

  18. Natural-pose hand detection in low-resolution images

    Directory of Open Access Journals (Sweden)

    Nyan Bo Bo1

    2009-07-01

    Full Text Available Robust real-time hand detection and tracking in video sequences would enable many applications in areas as diverse ashuman-computer interaction, robotics, security and surveillance, and sign language-based systems. In this paper, we introducea new approach for detecting human hands that works on single, cluttered, low-resolution images. Our prototype system, whichis primarily intended for security applications in which the images are noisy and low-resolution, is able to detect hands as smallas 2424 pixels in cluttered scenes. The system uses grayscale appearance information to classify image sub-windows as eithercontaining or not containing a human hand very rapidly at the cost of a high false positive rate. To improve on the false positiverate of the main classifier without affecting its detection rate, we introduce a post-processor system that utilizes the geometricproperties of skin color blobs. When we test our detector on a test image set containing 106 hands, 92 of those hands aredetected (86.8% detection rate, with an average false positive rate of 1.19 false positive detections per image. The rapiddetection speed, the high detection rate of 86.8%, and the low false positive rate together ensure that our system is useable asthe main detector in a diverse variety of applications requiring robust hand detection and tracking in low-resolution, clutteredscenes.

  19. 10 CFR 32.103 - Schedule D-prototype tests for ice detection devices containing strontium-90.

    Science.gov (United States)

    2010-01-01

    ... water and the strontium-90 shall be considered leakage. (e) Observations. After each of the tests... 10 Energy 1 2010-01-01 2010-01-01 false Schedule D-prototype tests for ice detection devices... § 32.103 Schedule D—prototype tests for ice detection devices containing strontium-90. An applicant for...

  20. Prospective detection of large prediction errors: a hypothesis testing approach

    International Nuclear Information System (INIS)

    Ruan, Dan

    2010-01-01

    Real-time motion management is important in radiotherapy. In addition to effective monitoring schemes, prediction is required to compensate for system latency, so that treatment can be synchronized with tumor motion. However, it is difficult to predict tumor motion at all times, and it is critical to determine when large prediction errors may occur. Such information can be used to pause the treatment beam or adjust monitoring/prediction schemes. In this study, we propose a hypothesis testing approach for detecting instants corresponding to potentially large prediction errors in real time. We treat the future tumor location as a random variable, and obtain its empirical probability distribution with the kernel density estimation-based method. Under the null hypothesis, the model probability is assumed to be a concentrated Gaussian centered at the prediction output. Under the alternative hypothesis, the model distribution is assumed to be non-informative uniform, which reflects the situation that the future position cannot be inferred reliably. We derive the likelihood ratio test (LRT) for this hypothesis testing problem and show that with the method of moments for estimating the null hypothesis Gaussian parameters, the LRT reduces to a simple test on the empirical variance of the predictive random variable. This conforms to the intuition to expect a (potentially) large prediction error when the estimate is associated with high uncertainty, and to expect an accurate prediction when the uncertainty level is low. We tested the proposed method on patient-derived respiratory traces. The 'ground-truth' prediction error was evaluated by comparing the prediction values with retrospective observations, and the large prediction regions were subsequently delineated by thresholding the prediction errors. The receiver operating characteristic curve was used to describe the performance of the proposed hypothesis testing method. Clinical implication was represented by miss

  1. Fraunhofer Institute for Nondestructive Testing. Annual report 1991

    International Nuclear Information System (INIS)

    1992-01-01

    Non-destructive testing is used as a tool for securing quality in the development and production of industrial products and in plant and process monitoring. The physical and metrological basics of suitable measuring methods are worked out, and test and handling systems are developed, which are then qualified according to existing regulations. Besides the methods for macroscopic error detection, high-resolution μ-zfP methods for following material development and for material characterization are worked on and utilized. The primary aim of the work is to secure the quality of industrial products. The more important individual aims are to develop methods for macrographic examinations for ensuring the safe operation of components subject to the Pressure Vessel Code, the nuclear energy regulations and comparable ordinances, plant monitoring, to ensure basic safety in the utilization of materials, process control and monitoring with regard to quality criteria and to perform damage analyses. (orig.) [de

  2. Evaluation of point-of-care tests for detecting microalbuminuria in ...

    African Journals Online (AJOL)

    Evaluation of point-of-care tests for detecting microalbuminuria in diabetic patients. ... creatinine (modified Jaffe) and albumin-to-creatinine ratio (ACR). Results: Linear regression analysis demonstrated a good correlation for the HemoCue® ...

  3. Ensuring services to the poor : learning from LLPMS

    International Development Research Centre (IDRC) Digital Library (Canada)

    fajardojp

    necessary steps to delivery services to ensure providing basic facilities but poverty remains central ... services, technological transfer, imparting training, input supply within reasonable ... Providing education, ensuring health facility, safe ..... a workshop organised to get feedback on the methodology of LLPMS the officials of.

  4. Earlier stages of colorectal cancer detected with immunochemical faecal occult blood tests

    NARCIS (Netherlands)

    van Rossum, L. G. M.; van Rijn, A. F.; van Munster, I. P.; Jansen, J. B. M. J.; Fockens, P.; Laheij, R. J. F.; Dekker, E.

    2009-01-01

    Background: The aim of colorectal cancer screening is to improve prognosis by the detection of early cancer and precursor stages. We compared the stage distribution of asymptomatic colorectal cancer patients detected by a positive immunochemical or guaiac-based faecal occult blood test (FOBT) with

  5. Improved anomaly detection using multi-scale PLS and generalized likelihood ratio test

    KAUST Repository

    Madakyaru, Muddu

    2017-02-16

    Process monitoring has a central role in the process industry to enhance productivity, efficiency, and safety, and to avoid expensive maintenance. In this paper, a statistical approach that exploit the advantages of multiscale PLS models (MSPLS) and those of a generalized likelihood ratio (GLR) test to better detect anomalies is proposed. Specifically, to consider the multivariate and multi-scale nature of process dynamics, a MSPLS algorithm combining PLS and wavelet analysis is used as modeling framework. Then, GLR hypothesis testing is applied using the uncorrelated residuals obtained from MSPLS model to improve the anomaly detection abilities of these latent variable based fault detection methods even further. Applications to a simulated distillation column data are used to evaluate the proposed MSPLS-GLR algorithm.

  6. Improved anomaly detection using multi-scale PLS and generalized likelihood ratio test

    KAUST Repository

    Madakyaru, Muddu; Harrou, Fouzi; Sun, Ying

    2017-01-01

    Process monitoring has a central role in the process industry to enhance productivity, efficiency, and safety, and to avoid expensive maintenance. In this paper, a statistical approach that exploit the advantages of multiscale PLS models (MSPLS) and those of a generalized likelihood ratio (GLR) test to better detect anomalies is proposed. Specifically, to consider the multivariate and multi-scale nature of process dynamics, a MSPLS algorithm combining PLS and wavelet analysis is used as modeling framework. Then, GLR hypothesis testing is applied using the uncorrelated residuals obtained from MSPLS model to improve the anomaly detection abilities of these latent variable based fault detection methods even further. Applications to a simulated distillation column data are used to evaluate the proposed MSPLS-GLR algorithm.

  7. Radon detection system, design, test and performance

    International Nuclear Information System (INIS)

    Balcazar, M.; Chavez, A.; Pina-Villalpando, G.; Navarrete, M.

    1999-01-01

    A portable radon detection system (α-Inin) has been designed and constructed for using it in adverse environmental conditions where humidity, temperature and chemical vaporous are present. The minimum integration time is in periods of 15 min during 41 days. A 12 V battery and a photovoltaic module allow the α-Inin autonomy in field measurements. Data is collected by means of a laptop computer where data processing and α-Inin programming are carried out. α-Inin performance was simultaneously tested in a controlled radon chamber, together with a commercial α-Meter

  8. [The advance of detection technology of HIV self-testing].

    Science.gov (United States)

    Yan, L; Xiao, P P; Yan, H J; Huan, X P; Fu, G F; Li, J J; Yang, H T

    2017-11-06

    At present, China's AIDS testing increased rapidly, but there are still many people living with HIV do not recognize their status, thus postponing the antiviral treatment time. HIV self-testing (HST) is an effective method to expand the testing, not only simple operation, easy to get a result, effectively protect the detection privacy, expand the selection of testers, suit to the entire population, but also the premise and basis of other AIDS comprehensive prevention measures, all over the world are promoting it. Because the HST has controversies in the window period, price and before and after controversial, and our country is in the initial stage of HST, so it is not to develop related policies, but more and more countries are in accordance with their own situations are modified or developed to allow to use rapid detection of AIDS policy to regulate the field. This paper analyzed and summarized the advantage and influence factors of HST promotion, HST believes that in the long term, the advantages outweigh the disadvantages, we need to formulate relevant policies, and improve the sensitivity of the kit, shorten the window period of time, production and promotion of operation standard of video, specification and testing the operating practices, preventing and reporting the possible social harm, investigation and understanding of the needs of the people of the crowd, to maximize the advantages of HST, find more infection, so as to curb the epidemic of AIDS.

  9. Ensuring Software IP Cleanliness

    Directory of Open Access Journals (Sweden)

    Mahshad Koohgoli

    2007-12-01

    Full Text Available At many points in the life of a software enterprise, determination of intellectual property (IP cleanliness becomes critical. The value of an enterprise that develops and sells software may depend on how clean the software is from the IP perspective. This article examines various methods of ensuring software IP cleanliness and discusses some of the benefits and shortcomings of current solutions.

  10. Evaluation of the β-CARBA™ test, a colorimetric test for the rapid detection of carbapenemase activity in Gram-negative bacilli.

    Science.gov (United States)

    Bernabeu, Sandrine; Dortet, Laurent; Naas, Thierry

    2017-06-01

    There is an urgent need for accurate and fast diagnostic tests to identify carbapenemase-producing bacteria. Here, we have evaluated a novel colorimetric test (the β-CARBA™ test; Bio-Rad) to detect carbapenemase-producing Gram-negative bacilli from cultured colonies. The performance of the β-CARBA™ test was compared with that of the Carba NP test (or the CarbAcineto NP test) and RAPIDEC ® CARBA NP (bioMérieux) using a collection of 290 isolates with characterized β-lactamase content. This collection included 199 carbapenemase producers (121 Enterobacteriaceae, 36 Pseudomonas and 42 Acinetobacter baumannii ) and 91 non-carbapenemase producers (55 Enterobacteriaceae, 20 Pseudomonas and 16 A. baumannii ). The β-CARBA™ test correctly detected 84.9% of the carbapenemase producers, including all KPC and IMP, 96.4% of VIM, 85.3% of NDM, 80.5% of OXA-48-like and 91.2% of A. baumannii -related OXA carbapenemases (OXA-23, OXA-40, OXA-58, OXA-143 and overexpressed OXA-51). All rare metallo-β-lactamases (SPM, AIM, GIM, DIM and SIM) were detected. Importantly, all non-KPC Ambler class A carbapenemases were not detected, including GES variants with carbapenemase activity ( n  = 6), IMI ( n  = 3), NMC-A ( n  = 1), SME ( n  = 2), FRI-1 ( n  = 1) and BIC-1 ( n  = 1). All non-carbapenemase producers gave a negative result except with OXA-163-, OXA-405- and one TEM-3-producing Citrobacter freundii . The overall sensitivity and specificity of the β-CARBA™ test were 84.9% and 95.6%, respectively. This test is easy to perform and to interpret by non-specialized staff members. Despite lack of specificity towards non-KPC Ambler class A and OXA-48-like carbapenemases, the β-CARBA™ test could complete the existing panel of tests available for the confirmation of carbapenemases in Gram-negatives. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For

  11. Human anti-HIV IgM detection by the OraQuick ADVANCE® Rapid HIV 1/2 Antibody Test.

    Science.gov (United States)

    Guillon, Geraldine; Yearwood, Graham; Snipes, Casey; Boschi, Daniel; Reed, Michael R

    2018-01-01

    The Centers for Disease Control and Prevention (CDC) and many public health jurisdictions continue to advocate for the most sensitive rapid HIV test that is available. Currently, the recommendation is to utilize tests that can detect HIV infection biomarkers within 30 days of infection, when initial immune responses are mounted. The infected patient's IgM response is often used to detect acute infection within a 20-25 days window after infection. This requirement applies to lab-based testing with automated analyzers and rapid, point of care (POC) testing used for screening in a non-clinical setting. A recent study has demonstrated that POC tests using a Protein A-based detection system can detect samples with predominantly HIV-1 IgM reactivity (Moshgabadi et al., 2015). The OraQuick ADVANCE ® Rapid HIV-1/2 Antibody Test (OraQuick ADVANCE ®) also uses Protein A as the detection protein in the antibody-binding colloidal gold conjugate, so it is expected that the OraQuick ADVANCE ® Test will also detect samples with predominantly IgM reactivity. This report definitively demonstrates that the OraQuick ADVANCE ® Test can detect IgM antibodies during an acute infection window period of approximately 20-25 days after infection, and is therefore suitable for use in testing environments requiring adherence to current CDC recommendations.

  12. Reverse-Transcriptase PCR Detection of Leptospira: Absence of Agreement with Single-Specimen Microscopic Agglutination Testing.

    Science.gov (United States)

    Waggoner, Jesse J; Balassiano, Ilana; Mohamed-Hadley, Alisha; Vital-Brazil, Juliana Magalhães; Sahoo, Malaya K; Pinsky, Benjamin A

    2015-01-01

    Reference diagnostic tests for leptospirosis include nucleic acid amplification tests, bacterial culture, and microscopic agglutination testing (MAT) of acute and convalescent serum. However, clinical laboratories often do not receive paired specimens. In the current study, we tested serum samples using a highly sensitive real-time nucleic acid amplification test for Leptospira and compared results to MAT performed on the same specimens. 478 serum samples from suspected leptospirosis cases in Rio de Janeiro were tested using a real-time RT-PCR for the diagnosis of leptospirosis, malaria and dengue (the Lepto-MD assay). The Lepto-MD assay detects all species of Leptospira (saprophytic, intermediate, and pathogenic), and in the current study, we demonstrate that this assay amplifies both Leptospira RNA and DNA. Dengue virus RNA was identified in 10 patients, and no cases of malaria were detected. A total of 65 samples (13.6%) were positive for Leptospira: 35 samples (7.3%) in the Lepto-MD assay, 33 samples (6.9%) by MAT, and 3 samples tested positive by both (kappa statistic 0.02). Poor agreement between methods was consistent regardless of the titer used to define positive MAT results or the day of disease at sample collection. Leptospira nucleic acids were detected in the Lepto-MD assay as late as day 22, and cycle threshold values did not differ based on the day of disease. When Lepto-MD assay results were added to the MAT results for all patients in 2008 (n=818), the number of detected leptospirosis cases increased by 30.4%, from 102 (12.5%) to 133 (16.3%). This study demonstrates a lack of agreement between nucleic acid detection of Leptospira and single-specimen MAT, which may result from the clearance of bacteremia coinciding with the appearance of agglutinating antibodies. A combined testing strategy for acute leptospirosis, including molecular and serologic testing, appears necessary to maximize case detection.

  13. Using electrolyte leakage tests to determine lifting windows and detect tissue damage

    Science.gov (United States)

    Richard W. Tinus

    2002-01-01

    Physiological testing is rapidly coming into use as a means to determine the condition of nursery stock and predict how it will respond to treatment or use. One such test, the electrolyte leakage test, can be used to measure cold hardiness and detect tissue damage. The principle of this test is that when cell membranes are damaged, electrolytes leak out into the water...

  14. Fault detection by surface seismic scanning tunneling macroscope: Field test

    KAUST Repository

    Hanafy, Sherif M.

    2014-08-05

    The seismic scanning tunneling macroscope (SSTM) is proposed for detecting the presence of near-surface impedance anomalies and faults. Results with synthetic data are consistent with theory in that scatterers closer to the surface provide brighter SSTM profiles than those that are deeper. The SSTM profiles show superresolution detection if the scatterers are in the near-field region of the recording line. The field data tests near Gulf of Aqaba, Haql, KSA clearly show the presence of the observable fault scarp, and identify the subsurface presence of the hidden faults indicated in the tomograms. Superresolution detection of the fault is achieved, even when the 35 Hz data are lowpass filtered to the 5-10 Hz band.

  15. Fault detection by surface seismic scanning tunneling macroscope: Field test

    KAUST Repository

    Hanafy, Sherif M.; Schuster, Gerard T.

    2014-01-01

    The seismic scanning tunneling macroscope (SSTM) is proposed for detecting the presence of near-surface impedance anomalies and faults. Results with synthetic data are consistent with theory in that scatterers closer to the surface provide brighter SSTM profiles than those that are deeper. The SSTM profiles show superresolution detection if the scatterers are in the near-field region of the recording line. The field data tests near Gulf of Aqaba, Haql, KSA clearly show the presence of the observable fault scarp, and identify the subsurface presence of the hidden faults indicated in the tomograms. Superresolution detection of the fault is achieved, even when the 35 Hz data are lowpass filtered to the 5-10 Hz band.

  16. A prescription fraud detection model.

    Science.gov (United States)

    Aral, Karca Duru; Güvenir, Halil Altay; Sabuncuoğlu, Ihsan; Akar, Ahmet Ruchan

    2012-04-01

    Prescription fraud is a main problem that causes substantial monetary loss in health care systems. We aimed to develop a model for detecting cases of prescription fraud and test it on real world data from a large multi-center medical prescription database. Conventionally, prescription fraud detection is conducted on random samples by human experts. However, the samples might be misleading and manual detection is costly. We propose a novel distance based on data-mining approach for assessing the fraudulent risk of prescriptions regarding cross-features. Final tests have been conducted on adult cardiac surgery database. The results obtained from experiments reveal that the proposed model works considerably well with a true positive rate of 77.4% and a false positive rate of 6% for the fraudulent medical prescriptions. The proposed model has the potential advantages including on-line risk prediction for prescription fraud, off-line analysis of high-risk prescriptions by human experts, and self-learning ability by regular updates of the integrative data sets. We conclude that incorporating such a system in health authorities, social security agencies and insurance companies would improve efficiency of internal review to ensure compliance with the law, and radically decrease human-expert auditing costs. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. SQL injection detection system

    OpenAIRE

    Vargonas, Vytautas

    2017-01-01

    SQL injection detection system Programmers do not always ensure security of developed systems. That is why it is important to look for solutions outside being reliant on developers. In this work SQL injection detection system is proposed. The system analyzes HTTP request parameters and detects intrusions. It is based on unsupervised machine learning. Trained by regular request data system detects outlier user parameters. Since training is not reliant on previous knowledge of SQL injections, t...

  18. 14C-urea breath test for the detection of Helicobacter pylori

    NARCIS (Netherlands)

    Veldhuyzen van Zanten, S. J.; Tytgat, K. M.; Hollingsworth, J.; Jalali, S.; Rshid, F. A.; Bowen, B. M.; Goldie, J.; Goodacre, R. L.; Riddell, R. H.; Hunt, R. H.

    1990-01-01

    The high urease activity of Helicobacter pylori can be used to detect this bacterium by noninvasive breath tests. We have developed a 14C-urea breath test which uses 5 microCi 14C with 50 mg nonradioactive urea. Breath samples are collected at baseline and every 30 min for 2 h. Our study compared

  19. Germination test as a fast method to detect glyphosate-resistant sourgrass

    Directory of Open Access Journals (Sweden)

    Marcos Altomani Neves Dias

    2015-01-01

    Full Text Available The occurrence of weed species with different levels of resistance to glyphosate has increasingly spread in agricultural areas. In Brazil, sourgrass is among the main species presenting issues in this regard. Thus, fast and reliable methods to detect glyphosate resistance are of special interest for this specie, either for research or rational management purposes. This study was carried out to verify the feasibility of using the germination test to detect glyphosate resistance in sourgrass. The experiment was conducted with two sourgrass biotypes, with different levels of susceptibility to glyphosate. The seeds were previously imbibed in solutions composed of 0, 0.1875%, 0.25%, 0.75%, 1.5%, 3% and 6% of glyphosate during two periods, five and ten minutes, and submitted to germination tests. The results indicate the germination test as a feasible and time-saving approach to evaluate glyphosate-resistant sourgrass, with results available in seven days.

  20. Germination test as a fast method to detect glyphosate-resistant sourgrass

    Directory of Open Access Journals (Sweden)

    Marcos Altomani Neves Dias

    2015-09-01

    Full Text Available The occurrence of weed species with different levels of resistance to glyphosate has increasingly spread in agricultural areas. In Brazil, sourgrass is among the main species presenting issues in this regard. Thus, fast and reliable methods to detect glyphosate resistance are of special interest for this specie, either for research or rational management purposes. This study was carried out to verify the feasibility of using the germination test to detect glyphosate resistance in sourgrass. The experiment was conducted with two sourgrass biotypes, with different levels of susceptibility to glyphosate. The seeds were previously imbibed in solutions composed of 0, 0.1875%, 0.25%, 0.75%, 1.5%, 3% and 6% of glyphosate during two periods, five and ten minutes, and submitted to germination tests. The results indicate the germination test as a feasible and time-saving approach to evaluate glyphosate-resistant sourgrass, with results available in seven days.

  1. Manufacturing and testing flexible microfluidic devices with optical and electrical detection mechanisms

    OpenAIRE

    Ivan, M.G.; Vivet, F.; Meinders, E.R.

    2010-01-01

    Flexible microfluidic devices made of poly(dimethylsiloxane) (PDMS) were manufactured by soft lithography, and tested in detection of ionic species using optical absorption spectroscopy and electrical measurements. PDMS was chosen due to its flexibility and ease of surface modification by exposure to plasma and UV treatment, its transparency in UV-Vis regions of the light spectrum, and biocompatibility. The dual-detection mechanism allows the user more freedom in choosing the detection tool, ...

  2. Rapid Detection of the Chlamydiaceae and Other Families in the Order Chlamydiales: Three PCR Tests

    Science.gov (United States)

    Everett, Karin D. E.; Hornung, Linda J.; Andersen, Arthur A.

    1999-01-01

    Few identification methods will rapidly or specifically detect all bacteria in the order Chlamydiales, family Chlamydiaceae. In this study, three PCR tests based on sequence data from over 48 chlamydial strains were developed for identification of these bacteria. Two tests exclusively recognized the Chlamydiaceae: a multiplex test targeting the ompA gene and the rRNA intergenic spacer and a TaqMan test targeting the 23S ribosomal DNA. The multiplex test was able to detect as few as 200 inclusion-forming units (IFU), while the TaqMan test could detect 2 IFU. The amplicons produced in these tests ranged from 132 to 320 bp in length. The third test, targeting the 23S rRNA gene, produced a 600-bp amplicon from strains belonging to several families in the order Chlamydiales. Direct sequence analysis of this amplicon has facilitated the identification of new chlamydial strains. These three tests permit ready identification of chlamydiae for diagnostic and epidemiologic study. The specificity of these tests indicates that they might also be used to identify chlamydiae without culture or isolation. PMID:9986815

  3. Field Tests of a Tractor Rollover Detection and Emergency Notification System.

    Science.gov (United States)

    Liu, B; Koc, A B

    2015-04-01

    The objective of this research was to assess the feasibility of a rollover detection and emergency notification system for farm tractors using field tests. The emergency notification system was developed based on a tractor stability model and implemented on a mobile electronic device with the iOS operating system. A complementary filter was implemented to combine the data from the accelerometer and gyroscope sensors to improve their accuracies in calculating the roll and pitch angles and the roll and pitch rates. The system estimates a stability index value during tractor operation, displays feedback messages when the stability index is lower than a preset threshold value, and transmits emergency notification messages when an overturn happens. Ten tractor rollover tests were conducted on a field track. The developed system successfully monitored the stability of the tractor during all of the tests. The iOS application was able to detect rollover accidents and transmit emergency notifications in the form of a phone call and email when an accident was detected. The system can be a useful tool for training and education in safe tractor operation. The system also has potential for stability monitoring and emergency notification of other on-road and off-road motorized vehicles.

  4. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Noel S. Ha

    2017-11-01

    Full Text Available Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET or single photon emission tomography (SPECT scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers must undergo quality control (QC testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a

  5. Manufacturing and testing flexible microfluidic devices with optical and electrical detection mechanisms

    Science.gov (United States)

    Ivan, Marius G.; Vivet, Frédéric; Meinders, Erwin R.

    2010-06-01

    Flexible microfluidic devices made of poly(dimethylsiloxane) (PDMS) were manufactured by soft lithography, and tested in detection of ionic species using optical absorption spectroscopy and electrical measurements. PDMS was chosen due to its flexibility and ease of surface modification by exposure to plasma and UV treatment, its transparency in UV-Vis regions of the light spectrum, and biocompatibility. The dual-detection mechanism allows the user more freedom in choosing the detection tool, and a functional device was successfully tested. Optical lithography was employed for manufacturing templates, which were subsequently used for imprinting liquid PDMS by thermal curing. Gold electrodes having various widths and distances among them were patterned with optical lithography on the top part which sealed the microchannels, and the devices were employed for detection of ionic species in aqueous salt solutions as well as micro-electrolysis cells. Due to the transparency of PDMS in UV-Vis the microfluidics were also used as photoreactors, and the in-situ formed charged species were monitored by applying a voltage between electrodes. Upon addition of a colorimetric pH sensor, acid was detected with absorption spectroscopy.

  6. Eddy Current Testing for Detecting Small Defects in Thin Films

    Science.gov (United States)

    Obeid, Simon; Tranjan, Farid M.; Dogaru, Teodor

    2007-03-01

    Presented here is a technique of using Eddy Current based Giant Magneto-Resistance sensor (GMR) to detect surface and sub-layered minute defects in thin films. For surface crack detection, a measurement was performed on a copper metallization of 5-10 microns thick. It was done by scanning the GMR sensor on the surface of the wafer that had two scratches of 0.2 mm, and 2.5 mm in length respectively. In another experiment, metal coatings were deposited over the layers containing five defects with known lengths such that the defects were invisible from the surface. The limit of detection (resolution), in terms of defect size, of the GMR high-resolution Eddy Current probe was studied using this sample. Applications of Eddy Current testing include detecting defects in thin film metallic layers, and quality control of metallization layers on silicon wafers for integrated circuits manufacturing.

  7. A fluorescence quenching test for the detection of flavonoid transformation.

    Science.gov (United States)

    Schoefer, L; Braune, A; Blaut, M

    2001-11-13

    A novel fluorescence quenching test for the detection of flavonoid degradation by microorganisms was developed. The test is based on the ability of the flavonoids to quench the fluorescence of 1,6-diphenyl-1,3,5-hexatriene (DPH). Several members of the anthocyanidins, flavones, isoflavones, flavonols, flavanones, dihydroflavanones, chalcones, dihydrochalcones and catechins were tested with regard to their quenching properties. The anthocyanidins were the most potent quenchers of DPH fluorescence, while the flavanones, dihydroflavanones and dihydrochalcones, quenched the fluorescence only weakly. The catechins had no visible impact on DPH fluorescence. The developed test allows a quick and easy differentiation between flavonoid-degrading and flavonoid-non-degrading bacteria. The investigation of individual reactions of flavonoid transformation with the developed test system is also possible.

  8. Detection of antibiotic residues in food by Charm II test

    International Nuclear Information System (INIS)

    Addali, Mohamed

    2014-01-01

    Antibiotics are used in food to: -therapy and prophylaxis, -increase the productivity of the food producing animals. The presence of antimicrobial residues: -constitutes a potential human health hazard. has significant impact on international food trade. has implications on technological process in dairy industry. Detection of antibiotic residues is of great interest. It helps protect humans against the effects of such residues, the more it can support the participation of our country in international trade. Charm II test is one of the methods of detection of antimicrobial residues. The tests utilize microbial or antibody receptor assay technology. The sample is incubated with a binding agent (microbial cells with specific receptor sites or with specific antibodies attached) and a tracer (the radio-labeled version of the antibiotic to be detected). The amount of tracer on the binding agent is measured using a scintillation counter and is compared to a pre-determined cut-off or control point. If contaminating antibiotic is present, it will prevent the binding of the tracer by occupying the receptors on the binding agent. The less labeled tracer detected, the more contaminating antibiotic there is present in the sample. This work, carried out at the Radiochemical Laboratory of the National Centre of Nuclear Science and Technology, has two parts: 1/ The first is reserved to a literature review provides an overview on antibiotics and the charm II method. 2/ The second is devoted to the experimental study and presentation of results.

  9. Detection of gonococcal infection : pros and cons of a rapid test.

    Science.gov (United States)

    Vickerman, Peter; Peeling, Rosanna W; Watts, Charlotte; Mabey, David

    2005-01-01

    WHO estimates that 62 million cases of gonorrhea occur annually worldwide. Untreated infection can cause serious long-term complications, especially in women. In addition, Neisseria gonorrheae infection can facilitate HIV transmission, and babies born to infected mothers are at risk of ocular infection, which can lead to blindness. Where diagnostic facilities are lacking, gonorrhea can be treated syndromically. However, this inevitably leads to over-treatment, especially in women in whom the syndrome of vaginal discharge may be due not to N. gonorrheae infection but to several other more prevalent conditions. Over-treatment is a major concern because of widespread N. gonorrheae antibiotic resistance. Moreover, a high proportion of gonorrhea cases are asymptomatic and so do not present for syndromic management. Such cases will only be detected by screening tests. The gold standard test for the detection of N. gonorrheae is culture, which has high sensitivity and specificity. However, it requires well trained staff and its performance is affected by specimen transport conditions. Other options include microscopy and tests that detect gonococcal antigen or nucleic acid. Nucleic acid amplification tests (NAATs) have higher sensitivity and can be used on non-invasive samples (urine). However, they can cross-react with other Neisseria species and are expensive, requiring highly trained staff and sophisticated equipment. In settings where patients are asked to return for laboratory results, some infected patients never receive treatment as they fail to return for their test results. This reduction in treatment, and the possible onward transmission of N. gonorrheae during any delay in treatment, means that a rapid test of lower sensitivity may be more effective if it results in patients being treated at the initial visit. Indeed, even with the low sensitivity of currently available rapid tests (50-70%), modeling shows that they can outperform gold standard tests in

  10. Cluster Detection Tests in Spatial Epidemiology: A Global Indicator for Performance Assessment.

    Directory of Open Access Journals (Sweden)

    Aline Guttmann

    Full Text Available In cluster detection of disease, the use of local cluster detection tests (CDTs is current. These methods aim both at locating likely clusters and testing for their statistical significance. New or improved CDTs are regularly proposed to epidemiologists and must be subjected to performance assessment. Because location accuracy has to be considered, performance assessment goes beyond the raw estimation of type I or II errors. As no consensus exists for performance evaluations, heterogeneous methods are used, and therefore studies are rarely comparable. A global indicator of performance, which assesses both spatial accuracy and usual power, would facilitate the exploration of CDTs behaviour and help between-studies comparisons. The Tanimoto coefficient (TC is a well-known measure of similarity that can assess location accuracy but only for one detected cluster. In a simulation study, performance is measured for many tests. From the TC, we here propose two statistics, the averaged TC and the cumulated TC, as indicators able to provide a global overview of CDTs performance for both usual power and location accuracy. We evidence the properties of these two indicators and the superiority of the cumulated TC to assess performance. We tested these indicators to conduct a systematic spatial assessment displayed through performance maps.

  11. Cluster Detection Tests in Spatial Epidemiology: A Global Indicator for Performance Assessment

    Science.gov (United States)

    Guttmann, Aline; Li, Xinran; Feschet, Fabien; Gaudart, Jean; Demongeot, Jacques; Boire, Jean-Yves; Ouchchane, Lemlih

    2015-01-01

    In cluster detection of disease, the use of local cluster detection tests (CDTs) is current. These methods aim both at locating likely clusters and testing for their statistical significance. New or improved CDTs are regularly proposed to epidemiologists and must be subjected to performance assessment. Because location accuracy has to be considered, performance assessment goes beyond the raw estimation of type I or II errors. As no consensus exists for performance evaluations, heterogeneous methods are used, and therefore studies are rarely comparable. A global indicator of performance, which assesses both spatial accuracy and usual power, would facilitate the exploration of CDTs behaviour and help between-studies comparisons. The Tanimoto coefficient (TC) is a well-known measure of similarity that can assess location accuracy but only for one detected cluster. In a simulation study, performance is measured for many tests. From the TC, we here propose two statistics, the averaged TC and the cumulated TC, as indicators able to provide a global overview of CDTs performance for both usual power and location accuracy. We evidence the properties of these two indicators and the superiority of the cumulated TC to assess performance. We tested these indicators to conduct a systematic spatial assessment displayed through performance maps. PMID:26086911

  12. CONFU: Configuration Fuzzing Testing Framework for Software Vulnerability Detection.

    Science.gov (United States)

    Dai, Huning; Murphy, Christian; Kaiser, Gail

    2010-01-01

    Many software security vulnerabilities only reveal themselves under certain conditions, i.e., particular configurations and inputs together with a certain runtime environment. One approach to detecting these vulnerabilities is fuzz testing. However, typical fuzz testing makes no guarantees regarding the syntactic and semantic validity of the input, or of how much of the input space will be explored. To address these problems, we present a new testing methodology called Configuration Fuzzing. Configuration Fuzzing is a technique whereby the configuration of the running application is mutated at certain execution points, in order to check for vulnerabilities that only arise in certain conditions. As the application runs in the deployment environment, this testing technique continuously fuzzes the configuration and checks "security invariants" that, if violated, indicate a vulnerability. We discuss the approach and introduce a prototype framework called ConFu (CONfiguration FUzzing testing framework) for implementation. We also present the results of case studies that demonstrate the approach's feasibility and evaluate its performance.

  13. Detectability Measurement of GPR for Buried Target in Self-Designed Test Field

    International Nuclear Information System (INIS)

    Son, Soo Jung; Shin, Byoung Chul

    2000-01-01

    In this paper, we were investigated the detectability on various specimen in self-designed test field using the GPR system with three antenna elements. The GPR system was constantly radiated 730MHz frequency. To examine the detectability on various condition, the test were experimented using different materials, size and buried depth. As an adjusted wave-propagation velocity, the location of hyperbolic curve pattern were displayed B-scan CRT. And the pattern was exactly positioned when it was compared to the real buried-depth. Therefore, we can confirm similarity between the wave-propagation velocity and previous results

  14. Imaging evaluation of infants with neuroblastoma detected by VMA screening spot test

    International Nuclear Information System (INIS)

    Fujioka, M.; Saiki, N.; Aihara, T.; Yamamoto, K.

    1988-01-01

    In the Saitama Prefecture in Japan, VMA (vanillyl manderic acid) screening spot test for detection of neuroblastoma has been performed in 173,046 infants in the years 1981-1986 and 15 infants were found to have neuroblastoma. Two infants had mediastinal tumors and the remainder, 13, had intraabdominal tumors. Only 7 infants had palpable masses. Although CT was documented to be the best imaging procedure to provide sufficient information for treatment, conventional radiographic examinations of the chest and abdomen, and abdominal ultrasonography were able, as initial imaging procedures, to detect reasonably small neuroblastomas in infants with a positive VMA screening test. (orig.)

  15. Bedside diagnosis of imported malaria using the Binax Now malaria antigen detection test

    DEFF Research Database (Denmark)

    Wiese, Lothar; Bruun, Brita; Baek, Leif

    2006-01-01

    Malaria may be misdiagnosed in non-endemic countries when the necessary experience for rapid expert microscopy is lacking. Rapid diagnostic tests may improve the diagnosis and may play a role as a bedside diagnostic tool. In a multicentre study we recruited patients suspected of malaria over...... a period of 14 months. The Binax Now Malaria rapid test was used at the bedside and in the clinical microbiology laboratory. The training of clinical staff was monitored and their experience with the use of the test was recorded. 542 patients were included, 80 of whom had malaria diagnosed by microscopy...... be useful for the diagnosis of P. falciparum malaria when used by routine laboratory staff, but could lead to misdiagnoses when used at the bedside. Microscopy is still essential in order to identify the few missed diagnoses, to determine the degree of parasitaemia, and to ensure species diagnosis...

  16. Real time testing of intelligent relays for synchronous distributed generation islanding detection

    Science.gov (United States)

    Zhuang, Davy

    As electric power systems continue to grow to meet ever-increasing energy demand, their security, reliability, and sustainability requirements also become more stringent. The deployment of distributed energy resources (DER), including generation and storage, in conventional passive distribution feeders, gives rise to integration problems involving protection and unintentional islanding. Distributed generators need to be islanded for safety reasons when disconnected or isolated from the main feeder as distributed generator islanding may create hazards to utility and third-party personnel, and possibly damage the distribution system infrastructure, including the distributed generators. This thesis compares several key performance indicators of a newly developed intelligent islanding detection relay, against islanding detection devices currently used by the industry. The intelligent relay employs multivariable analysis and data mining methods to arrive at decision trees that contain both the protection handles and the settings. A test methodology is developed to assess the performance of these intelligent relays on a real time simulation environment using a generic model based on a real-life distribution feeder. The methodology demonstrates the applicability and potential advantages of the intelligent relay, by running a large number of tests, reflecting a multitude of system operating conditions. The testing indicates that the intelligent relay often outperforms frequency, voltage and rate of change of frequency relays currently used for islanding detection, while respecting the islanding detection time constraints imposed by standing distributed generator interconnection guidelines.

  17. Computer-Based Testing: Test Site Security.

    Science.gov (United States)

    Rosen, Gerald A.

    Computer-based testing places great burdens on all involved parties to ensure test security. A task analysis of test site security might identify the areas of protecting the test, protecting the data, and protecting the environment as essential issues in test security. Protecting the test involves transmission of the examinations, identifying the…

  18. Cochlin-tomoprotein (CTP) detection test identified perilymph leakage preoperatively in revision stapes surgery.

    Science.gov (United States)

    Kataoka, Yuko; Ikezono, Tetsuo; Fukushima, Kunihiro; Yuen, Koji; Maeda, Yukihide; Sugaya, Akiko; Nishizaki, Kazunori

    2013-08-01

    Perilymphatic fistula (PLF) is defined as an abnormal leakage between perilymph from the labyrinth to the middle ear. Symptoms include hearing loss, tinnitus, and vertigo. The standard mode of PLF detection is intraoperative visualization of perilymph leakage and fistula, which ostensibly confirms the existence of PLF. Other possible methods of diagnosis include confirmation of pneumolabyrinth via diagnostic imaging. Recently, a cochlin-tomoprotein (CTP) detection test has been developed that allows definitive diagnosis of PLF-related hearing loss. We report the case of a 45-year-old man who presented with right-sided tinnitus, hearing loss, and dizziness 30 years after stapes surgery. Middle ear lavage was performed after myringotomy. A preoperative diagnosis of PLF was reached using the CTP detection test. Intraoperative observations included a necrotic long process of the incus, displaced wire piston, and fibrous tissue in the oval window. Perilymph leakage was not evident. The oval window was closed with fascia, and vertigo disappeared within 2 weeks postoperatively. When PLF is suspected after stapes surgery, the CTP detection test can be a useful, highly sensitive, and less invasive method for preoperative diagnosis. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    Science.gov (United States)

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  20. Duality ensures modular covariance

    International Nuclear Information System (INIS)

    Li Miao; Yu Ming

    1989-11-01

    We show that the modular transformations for one point functions on the torus, S(n), satisfy the polynomial equations derived by Moore and Seiberg, provided the duality property of the model is ensured. The formula for S(n) is derived by us previously and should be valid for any conformal field theory. As a consequence, the full consistency conditions for modular invariance at higher genus are completely guaranteed by duality of the theory on the sphere. (orig.)

  1. CUSUM-Logistic Regression analysis for the rapid detection of errors in clinical laboratory test results.

    Science.gov (United States)

    Sampson, Maureen L; Gounden, Verena; van Deventer, Hendrik E; Remaley, Alan T

    2016-02-01

    The main drawback of the periodic analysis of quality control (QC) material is that test performance is not monitored in time periods between QC analyses, potentially leading to the reporting of faulty test results. The objective of this study was to develop a patient based QC procedure for the more timely detection of test errors. Results from a Chem-14 panel measured on the Beckman LX20 analyzer were used to develop the model. Each test result was predicted from the other 13 members of the panel by multiple regression, which resulted in correlation coefficients between the predicted and measured result of >0.7 for 8 of the 14 tests. A logistic regression model, which utilized the measured test result, the predicted test result, the day of the week and time of day, was then developed for predicting test errors. The output of the logistic regression was tallied by a daily CUSUM approach and used to predict test errors, with a fixed specificity of 90%. The mean average run length (ARL) before error detection by CUSUM-Logistic Regression (CSLR) was 20 with a mean sensitivity of 97%, which was considerably shorter than the mean ARL of 53 (sensitivity 87.5%) for a simple prediction model that only used the measured result for error detection. A CUSUM-Logistic Regression analysis of patient laboratory data can be an effective approach for the rapid and sensitive detection of clinical laboratory errors. Published by Elsevier Inc.

  2. Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

    Science.gov (United States)

    Juarez, Alfredo; Harper, Susana Tapia

    2016-01-01

    The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

  3. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  4. Olodaterol and vilanterol detection in sport drug testing.

    Science.gov (United States)

    Chundela, Zdenek; Große, Joachim

    2015-01-01

    The possibility of the detection of olodaterol and vilanterol, two novel β2 -agonists, in human urine for the purpose of sport drug testing was investigated. Compounds of interest were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) employing methods commonly used in the World Anti-Doping Agency (WADA) accredited laboratories. For both substances, the respective parent compound was found to be a suitable target analyte for monitoring therapeutic dose administration. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Detection of colorectal serrated polyps by stool DNA testing: comparison with fecal immunochemical testing for occult blood (FIT.

    Directory of Open Access Journals (Sweden)

    Russell I Heigh

    Full Text Available Precursors to 1/3 of colorectal cancer (CRC, serrated polyps have been under-detected by screening due to their inconspicuous, non-hemorrhagic, and proximal nature. A new multi-target stool DNA test (multi-target sDNA shows high sensitivity for both CRC and advanced adenomas. Screen detection of serrated polyps by this approach requires further validation. We sought to assess and compare noninvasive detection of sessile serrated polyps (SSP ≥ 1 cm by sDNA and an occult blood fecal immunochemical test (FIT.In a blinded prospective study, a single stool sample used for both tests was collected from 456 asymptomatic adults prior to screening or surveillance colonoscopy (criterion standard. All 29 patients with SSP ≥ 1 cm were included as cases and all 232 with no neoplastic findings as controls. Buffered stool samples were processed and frozen on receipt; Exact Sciences performed sDNA in batches using optimized analytical methods. The sDNA multi-marker panel targets methylated BMP3 (mBMP3 and NDRG4, mutant KRAS, β-actin, and hemoglobin. FIT (Polymedco OC-FIT Check was performed in separate lab ≤ 2 days post defecation and evaluated at cutoffs of 50 (FIT-50 and 100 ng/ml (FIT-100.MEDIAN AGES: cases 61 (range 57-77, controls 62 (52-70, p = NS. Women comprised 59% and 51%, p = NS, respectively. SSP median size was 1.2 cm (1-3 cm, 93% were proximal, and 64% had synchronous diminutive polyps. Among multi-target sDNA markers, mBMP3 proved highly discriminant for detection of SSP ≥ 1 cm (AUC = 0.87, p<0.00001; other DNA markers provided no incremental sensitivity. Hemoglobin alone showed no discrimination (AUC = 0.50, p = NS. At matched specificities, detection of SSP ≥ 1 cm by stool mBMP3 was significantly greater than by FIT-50 (66% vs 10%, p = 0.0003 or FIT-100 (63% vs 0%, p<0.0001.In a screening and surveillance setting, SSP ≥ 1 cm can be detected noninvasively by stool assay of exfoliated DNA markers, especially mBMP3. FIT appears to

  6. The international experience of bacterial screen testing of platelet components with an automated microbial detection system: a need for consensus testing and reporting guidelines.

    Science.gov (United States)

    Benjamin, Richard J; McDonald, Carl P

    2014-04-01

    The BacT/ALERT microbial detection system (bioMerieux, Inc, Durham, NC) is in routine use in many blood centers as a prerelease test for platelet collections. Published reports document wide variation in practices and outcomes. A systematic review of the English literature was performed to describe publications assessing the use of the BacT/ALERT culture system on platelet collections as a routine screen test of more than 10000 platelet components. Sixteen publications report the use of confirmatory testing to substantiate initial positive culture results but use varying nomenclature to classify the results. Preanalytical and analytical variables that may affect the outcomes differ widely between centers. Incomplete description of protocol details complicates comparison between sites. Initial positive culture results range from 539 to 10606 per million (0.054%-1.061%) and confirmed positive from 127 to 1035 per million (0.013%-0.104%) donations. False-negative results determined by outdate culture range from 662 to 2173 per million (0.066%-0.217%) and by septic reactions from 0 to 66 per million (0%-0.007%) collections. Current culture protocols represent pragmatic compromises between optimizing analytical sensitivity and ensuring the timely availability of platelets for clinical needs. Insights into the effect of protocol variations on outcomes are generally restricted to individual sites that implement limited changes to their protocols over time. Platelet manufacturers should reassess the adequacy of their BacT/ALERT screening protocols in light of the growing international experience and provide detailed documentation of all variables that may affect culture outcomes when reporting results. We propose a framework for a standardized nomenclature for reporting of the results of BacT/ALERT screening. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Probability of defect detection of Posiva's electron beam weld

    International Nuclear Information System (INIS)

    Kanzler, D.; Mueller, C.; Pitkaenen, J.

    2013-12-01

    The report 'Probability of Defect Detection of Posiva's electron beam weld' describes POD curves of four NDT methods radiographic testing, ultrasonic testing, eddy current testing and visual testing. POD-curves are based on the artificial defects in reference blocks. The results are devoted to the demonstration of suitability of the methods for EB weld testing. Report describes methodology and procedure applied by BAM. Report creates a link from the assessment of the reliability and inspection performance to the risk assessment process of the canister final disposal project. Report ensures the confirmation of the basic quality of the NDT methods and their capability to describe the quality of the EB-weld. The probability of detection curves are determined based on the MIL-1823 standard and it's reliability guidelines. The MIL-1823 standard was developed for the determination of integrity of gas turbine engines for the US military. In the POD-process there are determined as a key parameter for the defect detectability the a90/95 magnitudes, i.e. the size measure a of the defect, for which the lower 95 % confidence band crosses the 90 % POD level. By this way can be confirmed that defects with a size of a90/95 will be detected with 90 % probability. In case the experiment will be repeated 5 % might fall outside this confidence limit. (orig.)

  8. [Micron]ADS-B Detect and Avoid Flight Tests on Phantom 4 Unmanned Aircraft System

    Science.gov (United States)

    Arteaga, Ricardo; Dandachy, Mike; Truong, Hong; Aruljothi, Arun; Vedantam, Mihir; Epperson, Kraettli; McCartney, Reed

    2018-01-01

    Researchers at the National Aeronautics and Space Administration Armstrong Flight Research Center in Edwards, California and Vigilant Aerospace Systems collaborated for the flight-test demonstration of an Automatic Dependent Surveillance-Broadcast based collision avoidance technology on a small unmanned aircraft system equipped with the uAvionix Automatic Dependent Surveillance-Broadcast transponder. The purpose of the testing was to demonstrate that National Aeronautics and Space Administration / Vigilant software and algorithms, commercialized as the FlightHorizon UAS"TM", are compatible with uAvionix hardware systems and the DJI Phantom 4 small unmanned aircraft system. The testing and demonstrations were necessary for both parties to further develop and certify the technology in three key areas: flights beyond visual line of sight, collision avoidance, and autonomous operations. The National Aeronautics and Space Administration and Vigilant Aerospace Systems have developed and successfully flight-tested an Automatic Dependent Surveillance-Broadcast Detect and Avoid system on the Phantom 4 small unmanned aircraft system. The Automatic Dependent Surveillance-Broadcast Detect and Avoid system architecture is especially suited for small unmanned aircraft systems because it integrates: 1) miniaturized Automatic Dependent Surveillance-Broadcast hardware; 2) radio data-link communications; 3) software algorithms for real-time Automatic Dependent Surveillance-Broadcast data integration, conflict detection, and alerting; and 4) a synthetic vision display using a fully-integrated National Aeronautics and Space Administration geobrowser for three dimensional graphical representations for ownship and air traffic situational awareness. The flight-test objectives were to evaluate the performance of Automatic Dependent Surveillance-Broadcast Detect and Avoid collision avoidance technology as installed on two small unmanned aircraft systems. In December 2016, four flight tests

  9. Analysis of brief language tests in the detection of cognitive decline and dementia

    Directory of Open Access Journals (Sweden)

    Marcia Radanovic

    Full Text Available Abstract Lexical access difficulties are frequent in normal aging and initial stages of dementia. Verbal fluency tests are valuable to detect cognitive decline, evidencing lexico-semantic and executive dysfunction. Objectives: To establish which language tests can contribute in detecting dementia and to verify schooling influence on subject performance. Method: 74 subjects: 33 controls, 17 Clinical Dementia Rating (CDR 0.5 and 24 (Brief Cognitive Battery - BCB e Boston Naming Test - BNT 1 were compared in tests of semantic verbal fluency (animal and fruit, picture naming (BCB and BNT and the language items of Mini Mental State Examination (MMSE. Results: There were significant differences between the control group and both CDR 0.5 and CDR 1 in all tests. Cut-off scores were: 11 and 10 for animal fluency, 8 for fruit fluency (in both, 8 and 9 for BCB naming. The CDR 0.5 group performed better than the CDR 1 group only in animal fluency. Stepwise multiple regression revealed fruit fluency, animal fluency and BCB naming as the best discriminators between patients and controls (specificity: 93.8%; sensitivity: 91.3%. In controls, comparison between illiterates and literates evidenced schooling influence in all tests, except for fruit fluency and BCB naming. In patients with dementia, only fruit fluency was uninfluenced by schooling. Conclusion: The combination of verbal fluency tests in two semantic categories along with a simple picture naming test is highly sensitive in detecting cognitive decline. Comparison between literate and illiterate subjects shows a lesser degree of influence of schooling on the selected tests, thus improving discrimination between low performance and incipient cognitive decline.

  10. Comparison and transfer testing of multiplex ligation detection methods for GM plants

    Directory of Open Access Journals (Sweden)

    Ujhelyi Gabriella

    2012-01-01

    Full Text Available Abstract Background With the increasing number of GMOs on the global market the maintenance of European GMO regulations is becoming more complex. For the analysis of a single food or feed sample it is necessary to assess the sample for the presence of many GMO-targets simultaneously at a sensitive level. Several methods have been published regarding DNA-based multidetection. Multiplex ligation detection methods have been described that use the same basic approach: i hybridisation and ligation of specific probes, ii amplification of the ligated probes and iii detection and identification of the amplified products. Despite they all have this same basis, the published ligation methods differ radically. The present study investigated with real-time PCR whether these different ligation methods have any influence on the performance of the probes. Sensitivity and the specificity of the padlock probes (PLPs with the ligation protocol with the best performance were also tested and the selected method was initially validated in a laboratory exchange study. Results Of the ligation protocols tested in this study, the best results were obtained with the PPLMD I and PPLMD II protocols and no consistent differences between these two protocols were observed. Both protocols are based on padlock probe ligation combined with microarray detection. Twenty PLPs were tested for specificity and the best probes were subjected to further evaluation. Up to 13 targets were detected specifically and simultaneously. During the interlaboratory exchange study similar results were achieved by the two participating institutes (NIB, Slovenia, and RIKILT, the Netherlands. Conclusions From the comparison of ligation protocols it can be concluded that two protocols perform equally well on the basis of the selected set of PLPs. Using the most ideal parameters the multiplicity of one of the methods was tested and 13 targets were successfully and specifically detected. In the

  11. Ensuring safe water in post-chemical, biological, radiological and nuclear emergencies

    Science.gov (United States)

    Amar, Praveen Kumar

    2010-01-01

    Disaster scenarios are dismal and often result in mass displacement and migration of people. In eventuality of emergency situations, people need to be rehabilitated and provided with an adequate supply of drinking water, the most essential natural resource needed for survival, which is often not easily available even during non-disaster periods. In the aftermath of a natural or human-made disaster affecting mankind and livestock, the prime aim is to ensure supply of safe water to reduce the occurrence and spread of water borne disease due to interrupted, poor and polluted water supply. Chemical, biological, radiological and nuclear (CBRN) emergencies augment the dilemma as an additional risk of “contamination” is added. The associated risks posed to health and life should be reduced to as low as reasonably achievable. Maintaining a high level of preparedness is the crux of quick relief and efficient response to ensure continuous supply of safe water, enabling survival and sustenance. The underlying objective would be to educate and train the persons concerned to lay down the procedures for the detection, cleaning, and treatment, purification including desalination, disinfection, and decontamination of water. The basic information to influence the organization of preparedness and execution of relief measures at all levels while maintaining minimum standards in water management at the place of disaster, are discussed in this article. PMID:21829321

  12. Ensuring safe water in post-chemical, biological, radiological and nuclear emergencies

    Directory of Open Access Journals (Sweden)

    Praveen Kumar Amar

    2010-01-01

    Full Text Available Disaster scenarios are dismal and often result in mass displacement and migration of people. In eventuality of emergency situations, people need to be rehabilitated and provided with an adequate supply of drinking water, the most essential natural resource needed for survival, which is often not easily available even during non-disaster periods. In the aftermath of a natural or human-made disaster affecting mankind and livestock, the prime aim is to ensure supply of safe water to reduce the occurrence and spread of water borne disease due to interrupted, poor and polluted water supply. Chemical, biological, radiological and nuclear (CBRN emergencies augment the dilemma as an additional risk of "contamination" is added. The associated risks posed to health and life should be reduced to as low as reasonably achievable. Maintaining a high level of preparedness is the crux of quick relief and efficient response to ensure continuous supply of safe water, enabling survival and sustenance. The underlying objective would be to educate and train the persons concerned to lay down the procedures for the detection, cleaning, and treatment, purification including desalination, disinfection, and decontamination of water. The basic information to influence the organization of preparedness and execution of relief measures at all levels while maintaining minimum standards in water management at the place of disaster, are discussed in this article.

  13. An ELISA test for the detection of antibodies to Legionella pneumophila.

    OpenAIRE

    Wreghitt, T G; Nagington, J; Gray, J

    1982-01-01

    An enzyme-linked immunosorbent assay (ELISA) test has been developed to detect antibodies to Legionella pneumophila serogroup 1. There is good correlation between indirect fluorescent antibody (IFA) and ELISA titres but ELISA is more sensitive.

  14. Perspectives of Security Ensuring within the Framework of Barcelona Process

    Directory of Open Access Journals (Sweden)

    T N Kirabaev

    2009-06-01

    Full Text Available Barcelona process was aimed to become an important mechanism in the realization of ideas of peace, stability and security ensuring in the Mediterranean Sea region. Cooperation in the sphere of security ensuring means openness of the regional states, social and economic reforms, human rights protection. The article deals with the problem of security ensuring by nonmilitary means.

  15. The sensitivity of tests to detect in vivo platelet activation induced by ...

    African Journals Online (AJOL)

    No influence on the results of the platelet function tests was found. Tile only test capable of detecting limited injury to the endothelium was the measurement of plasma PF4: The mean platelet life-span (MPLS) shortened, mean platelet density decreased, the circulating platelet aggregate ratio decreased, and plasma levels ...

  16. Fault Detection Coverage Quantification of Automatic Test Functions of Digital I and C System in NPPs

    International Nuclear Information System (INIS)

    Choi, Jong Gyun; Lee, Seung Jun; Hur, Seop; Lee, Young Jun; Jang, Seung Cheol

    2011-01-01

    Recently, analog instrument and control (I and C) systems in nuclear power plants (NPPs) have been replaced with digital systems for safer and more efficient operations. Digital I and C systems have adopted various fault-tolerant techniques that help the system correctly and safely perform the specific required functions in spite of the presence of faults. Each fault-tolerant technique has a different inspection period from real-time monitoring to monthly testing. The range covered by each fault-tolerant technique is also different. The digital I and C system, therefore, adopts multiple barriers consisting of various fault-tolerant techniques to increase total fault detection coverage. Even though these fault-tolerant techniques are adopted to ensure and improve the safety of a system, their effects have not been properly considered yet in most PSA models. Therefore, it is necessary to develop an evaluation method that can describe these features of a digital I and C system. Several issues must be considered in the fault coverage estimation of a digital I and C system, and two of them were handled in this work. The first is to quantify the fault coverage of each fault-tolerant technique implemented in the system, and the second is to exclude the duplicated effect of fault-tolerant techniques implemented simultaneously at each level of the system's hierarchy, as a fault occurring in a system might be detected by one or more fault-tolerant techniques. For this work, fault injection experiment was used to obtain the exact relations between faults and multiple barriers of fault-tolerant techniques. This experiment was applied to a bistable processor (BP) of a reactor protection system

  17. Rapid detection of methicillin resistance in Staphylococcus aureus isolates by the MRSA-screen latex agglutination test

    NARCIS (Netherlands)

    W.B. van Leeuwen (Willem); C. van Pelt (Cindy); A. Luijendijk (Ad); H.A. Verbrugh (Henri); W.H.F. Goessens (Wil)

    1999-01-01

    textabstractThe slide agglutination test MRSA-Screen (Denka Seiken Co., Niigata, Japan) was compared with the mecA PCR ("gold standard") for the detection of methicillin resistance in Staphylococcus aureus. The MRSA-Screen test detected the penicillin-binding protein 2a

  18. MTG infrared sounder detection chain: first radiometric test results

    Science.gov (United States)

    Dumestier, D.; Pistone, F.; Dartois, T.; Blazquez, E.

    2017-11-01

    Europe's next fleet of geostationary meteorological satellites, MeteoSat Third Generation, will introduce new functions in addition to continuity of high-resolution meteorological data. The atmosphere Infrared Sounder (IRS), as high -end instrument, is part of this challenging program. IRS principle is a Fourier Transform Interferometer, which allows recomposing atmospheric spectrum after infrared photons detection. Transmission spectrums will be used to support numerical weather prediction. IRS instrument is able to offer full disk coverage in one hour, an on-ground resolution of 4 by 4 km, in two spectral bands (MWIR: 1600 to 2175cm-1 and LWIR: 700 to 1210cm-1) with a spectral resolution of 0.6cm-1. Among critical technologies and processes, IRS detection chain shall offer outstanding characteristics in terms of radiometric performance like Signal to Noise Ratio (SNR), dynamic range and linearity. Selected detectors are HgCdTe two-dimensions arrays, cooled at 55 Kelvins, hybridized on snapshot silicon read-out circuit at 160x160 format. Video electronics present 16 bits resolution, and the whole detection chain (Detectors and electronics) permits to reach SNR between 2 000 and 10 000 as requested by the application. Radiometric onground test results performed on design representative detection chains are presented and are confirming the challenging phase A design choices.

  19. A new efficient statistical test for detecting variability in the gene expression data.

    Science.gov (United States)

    Mathur, Sunil; Dolo, Samuel

    2008-08-01

    DNA microarray technology allows researchers to monitor the expressions of thousands of genes under different conditions. The detection of differential gene expression under two different conditions is very important in microarray studies. Microarray experiments are multi-step procedures and each step is a potential source of variance. This makes the measurement of variability difficult because approach based on gene-by-gene estimation of variance will have few degrees of freedom. It is highly possible that the assumption of equal variance for all the expression levels may not hold. Also, the assumption of normality of gene expressions may not hold. Thus it is essential to have a statistical procedure which is not based on the normality assumption and also it can detect genes with differential variance efficiently. The detection of differential gene expression variance will allow us to identify experimental variables that affect different biological processes and accuracy of DNA microarray measurements.In this article, a new nonparametric test for scale is developed based on the arctangent of the ratio of two expression levels. Most of the tests available in literature require the assumption of normal distribution, which makes them inapplicable in many situations, and it is also hard to verify the suitability of the normal distribution assumption for the given data set. The proposed test does not require the assumption of the distribution for the underlying population and hence makes it more practical and widely applicable. The asymptotic relative efficiency is calculated under different distributions, which show that the proposed test is very powerful when the assumption of normality breaks down. Monte Carlo simulation studies are performed to compare the power of the proposed test with some of the existing procedures. It is found that the proposed test is more powerful than commonly used tests under almost all the distributions considered in the study. A

  20. wft4galaxy: a workflow testing tool for galaxy.

    Science.gov (United States)

    Piras, Marco Enrico; Pireddu, Luca; Zanetti, Gianluigi

    2017-12-01

    Workflow managers for scientific analysis provide a high-level programming platform facilitating standardization, automation, collaboration and access to sophisticated computing resources. The Galaxy workflow manager provides a prime example of this type of platform. As compositions of simpler tools, workflows effectively comprise specialized computer programs implementing often very complex analysis procedures. To date, no simple way to automatically test Galaxy workflows and ensure their correctness has appeared in the literature. With wft4galaxy we offer a tool to bring automated testing to Galaxy workflows, making it feasible to bring continuous integration to their development and ensuring that defects are detected promptly. wft4galaxy can be easily installed as a regular Python program or launched directly as a Docker container-the latter reducing installation effort to a minimum. Available at https://github.com/phnmnl/wft4galaxy under the Academic Free License v3.0. marcoenrico.piras@crs4.it. © The Author 2017. Published by Oxford University Press.

  1. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  2. The uriscreen test to detect significant asymptomatic bacteriuria during pregnancy.

    Science.gov (United States)

    Teppa, Roberto J; Roberts, James M

    2005-01-01

    Asymptomatic bacteriuria (ASB) occurs in 2-11% of pregnancies and it is a clear predisposition to the development of acute pyelonephritis, which, in turn, poses risk to mother and fetus. Treatment of bacteriuria during pregnancy reduces the incidence of pyelonephritis. Therefore, it is recommended to screen for ASB at the first prenatal visit. The gold standard for detection of bacteriuria during pregnancy is urine culture, but this test is expensive, time-consuming, and labor-intensive. To determine the reliability of an enzymatic urine screening test (Uriscreen; Savyon Diagnostics, Ashdod, Israel) for detecting ASB in pregnancy. Catheterized urine samples were collected from 150 women who had routine prenatal screening for ASB. Patients with urinary symptoms, active vaginal bleeding, or who were previously on antibiotics therapy were excluded from the study. Sensitivity, specificity, and the positive and negative predictive values for the Uriscreen were estimated using urine culture as the criterion standard. Urine cultures were considered positive if they grew >10(5) colony-forming units of a single uropathogen. Twenty-eight women (18.7%) had urine culture results indicating significant bacteriuria, and 17 of these 28 specimens had positive enzyme activity. Of 122 samples with no growth, 109 had negative enzyme activity. Sensitivity, specificity, and positive and negative predictive values for the Uriscreen test were 60.7% (+/-18.1), 89.3% (+/-5.6), 56.6%, and 90.8%, respectively. The Uriscreen test had inadequate sensitivity for rapid screening of bacteriuria in pregnancy.

  3. Accelerated detection of brown-rot decay : comparison of soil block test, chemical analysis, mechanical properties, and immunodetection

    Science.gov (United States)

    C. A. Clausen; S. N. Kartal

    2003-01-01

    Early detection of wood decay is critical because decay fungi can cause rapid structural failure. The objective of this study was to compare the sensitivity of different methods purported to detect brown-rot decay in the early stages of development. The immunodiagnostic wood decay (IWD)test, soil block test/cake pan test, mechanical property tests, and chemical...

  4. Test-day records as a tool for subclinical ketosis detection

    OpenAIRE

    Gantner Vesna; Potočnik K.; Jovanovac Sonja

    2009-01-01

    The prevalence, as well as the effect of subclinical ketosis on daily milk yield, was observed using 1.299,630 test-day records collected from January 2000 to December 2005 on 73,255 Slovenian Holstein cows. Subclinical ketosis was indicated by the fat to protein ratio (F/P ratio) higher than 1.5 in cows that yielded between 33 to 50 kg of milk per day (Eicher, 2004). The ketosis index was defined in relation to the timing of subclinical ketosis detection to the subsequent measures of test-da...

  5. Photoacoustic detection of NH3 in power plant emissions

    International Nuclear Information System (INIS)

    Rassmussen, O.

    1991-01-01

    The paper describes a photoacoustic spectrometer initially designed for detection of NH 3 in power plant emission with a detection limit below 1 ppm. The radiation source is a high tunable CO 2 waveguide laser emitting its own frequency standard in one of 90 laserlines. The detection is performed at reduced pressure where the vibration-rotation transitions give an unambiguous fingerprint for each trace gas. Immunity against interference is ensured by recording this characteristic spectral fingerprint over the tuning range of the laser, and problems associated with the high concentration of CO 2 or other interfering molecules are further eliminated by utilizing the effect of kinetic cooling in the photoacoustic phase. The use of a CO 2 laser as radiation source combined with the highly sensitive photoacoustic detection provides a great possibility of measuring a wide range of air pollutants in the range down to ppt concentrations. Experimental measurements have been carried out on gases like sulfur dioxide, ethylene, sulfur hexafluoride, vinylchloride, ozone, etc., and many others have been theoretically examined to give a high response in the CO 2 laser frequency range. A computerized NH 3 spectrometer has been constructed and tested under realistic conditions at a Danish power plant operating a test facility for selective non-catalytic reduction of NO x . Results of this test will be presented

  6. Strategy for monitoring and ensuring safe operation of Russian gas transportation systems

    Directory of Open Access Journals (Sweden)

    Dudin Sergey

    2017-01-01

    Full Text Available The authors examined the legislative framework of the Russian Federation operating in the field of industrial safety, and described how to obtain a license to operate hazardous production facilities. The paper demonstrates that the importance should be given to the quality and completeness of the background information, as well as the choice of inspection strategy in evaluating the technical condition of the line section of main gas pipelines. As a part of a package of measures to ensure industrial safety and technical reliability of existing gas pipelines it is proposed to carry out conditioning of their line sections. The paper describes general requirements for pipeline inspection, which include: detection efficiency of dangerous damages and major leaks, maximum accuracy of detection of the defect location, continuity of monitoring throughout the entire range of operation modes of the pipeline, cost recovery at the stages of development and operation of control systems, forecasting the state of the pipeline and the effects of accidents. In practice, these parameters have the prevailing significance.

  7. Detection of IgE insulin antibody with radioallergosorbent test

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, S; Nakayama, H; Sasaki, T; Watanabe, T; Aoki, S [Hokkaido Univ., Sapporo (Japan). 2. Dept. of Medicine; Saito, N [Sapporo Railway Hospital (Japan). Dept. of Medicine

    1978-01-01

    An in vitro method for detecting IgE insulin antibody using the principle of the radioallergosorbent test (RAST) is described. In six patients with insulin allergy, the RAST values were higher than in normal persons or insulin-treated diabetics without insulin allergy. No differences were observed between normal persons and insulin-treated diabetics without insulin allergy. Moreover, it was observed that in one patient treated with highly purified insulin, there was a gradual decrease of RAST value parallel to the radioinsulin binding activity and clinical allergic symptoms. The RAST value of insulin is slightly inhibited by non-IgE antibodies and is, therefore, a semiquantitative value. However, the RAST is simple to perform and reproducible; it is therefore very useful in the detection of IgE insulin antibodies.

  8. Detection of IgE insulin antibody with radioallergosorbent test

    International Nuclear Information System (INIS)

    Nakagawa, S.; Nakayama, H.; Sasaki, T.; Watanabe, T.; Aoki, S.; Saito, N.

    1978-01-01

    An in vitro method for detecting IgE insulin antibody using the principle of the radioallergosorbent test (RAST) is described. In six patients with insulin allergy, the RAST values were higher than in normal persons or insulin-treated diabetics without insulin allergy. No differences were observed between normal persons and insulin-treated diabetics without insulin allergy. Moreover, it was observed that in one patient treated with highly purified insulin, there was a gradual decrease of RAST value parallel to the radioinsulin binding activity and clinical allergic symptoms. The RAST value of insulin is slightly inhibited by non-IgE antibodies and is, therefore, a semiquantitative value. However, the RAST is simple to perform and reproducible; it is therefore very useful in the detection of IgE insulin antibodies. (orig.) [de

  9. Utility of Direct Fluorescent Antibody Test for detection of Chlamydia trachomatis and its detection in male patients with non gonococcal urethritis in New Delhi

    Directory of Open Access Journals (Sweden)

    Agrawal S

    2003-03-01

    Full Text Available The purpose of this study was assessment of prevalence of Chlamydia trachomatis and utility of Direct Fluorescent Antibody (DFA test for its detection in male patients with non gonococcal urethritis in New Delhi , India Thirty male patients with symptoms of dysuria showing polymorphs in their gram stained urethral smears with no evidence of Neisseria gonorrhoeae, and negative for Trichomonas vaginalis and Candida albicans by wet mount were subjected to DFA test for detection of C. trachomatis in urethral samples. Microscopic examination of gram stained urethral smears revealed 5-7 polymorphs / HPF in 90% of the patients. Evidence of C. trachomatis with DFA (MicroTrak was detected in 11 cases (36.67% when a cut off of 10 elementary bodies was considered essential. It is concluded that C. trachomatis is an important cause of non gonococcal urethritis in male patients in New Delhi and DFA test is a useful diagnostic tool in its detection. Where facilities are not available for its detection antichlamydial therapy should be recommended emperically.

  10. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  11. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  12. Detection of extended-spectrum β-lactamase in Enterobacter spp.--evaluation of six phenotypic tests.

    Science.gov (United States)

    Nogueira-Miranda, Keite da Silva; Palmeiro, Jussara Kasuko; Conte, Danieli; Maia, Fernanda Valverde; Reason, Iara Taborda de Messias; Monteiro, Cristina Leise; Dalla-Costa, Libera Maria

    2012-02-01

    Extended-spectrum β-lactamases (ESBL) are plasmid-mediated enzymes that hydrolyze cephalosporins and monobactams. The lack of a standard method to detect ESBL in Enterobacter spp. has led to underestimating its frequency. The aim of this study was to evaluate ESBL detection in Enterobacter spp. By the double-disk synergy test (DDST) and combined disk test (CDT) assay using cefepime, cefotaxime, and ceftazime as substrates for ESBL, plus AmpC inhibitors in different associations. A total of 83 Enterobacter spp. ESBL and 31 non-ESBL Enterobacter spp. were tested, and a cutoff point ≥3 mm was defined using a receiver operating characteristic (ROC) curve for combined disc methods. All tests showed 100% specificity. The sensitivity was 89.2% for DDST and CDT without AmpC inibitor, 90.4% in the combined disc test in Mueller-Hinton agar containing phenylboronic acid (CDT-PBAA), and 94% in the combined disc test in Mueller-Hinton agar containing cloxacillin (CDT-CLXA). Cefepime was the best substrate, mainly when AmpC inhibitors were not used. However, superior results were achieved when all cephalosporins were evaluated together. In conclusion, to improve ESBL detection in Enterobacter spp., some modifications in phenotypic tests are needed, such as to reduce the distance between the discs to 20 mm in DDST, to use a cutoff point for ≥3 mm on the CDT, and to include a cefepime disk or an inhibitor of AmpC in all tests.

  13. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Full Text Available Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Resumo: Objetivo: Avaliar o teste QuickVue® RSV Test Kit (QUIDEL Corp, CA, EUA para o diagn

  14. The UX Book Process and Guidelines for Ensuring a Quality User Experience

    CERN Document Server

    Hartson, Rex

    2012-01-01

    This is a comprehensive textbook on designing interaction to ensure a quality user experience. Combining breadth, depth, and practical applications, this book takes a time-tested process-and-guidelines approach that provides readers with actionable methods and techniques while retaining a firm grounding in HCI concepts and theory. The authors will guide you through the UX lifecycle process, including contextual inquiry and analysis, requirements extraction, design ideation and creation, practical design production, prototyping, and UX evaluation. Development activities are linked via handof

  15. 34 CFR 602.18 - Ensuring consistency in decision-making.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Ensuring consistency in decision-making. 602.18 Section... relies on for making accrediting decisions is accurate; and (e) Provides the institution or program with... Criteria for Recognition Required Standards and Their Application § 602.18 Ensuring consistency in decision...

  16. Performance of immunochromatographic and ELISA tests for detecting fallow deer infected with Mycobacterium bovis.

    Science.gov (United States)

    Boadella, M; Barasona, J A; Diaz-Sanchez, S; Lyashchenko, K P; Greenwald, R; Esfandiari, J; Gortazar, C

    2012-04-01

    Fallow deer (Dama dama) are widely distributed as natural or naturalised populations, as well as in game parks and deer farms. We used 157 fallow deer sampled in populations considered to be Mycobacterium tuberculosis complex (MTC) free and 73 Mycobacterium bovis-infected fallow deer confirmed postmortem by culture to evaluate the diagnostic performance of two tests for the detection of anti-mycobacterial antibodies: the dual path platform (DPP) VetTB assay and the bovine purified protein derivative (bPPD) ELISA. We also compared their sensitivity with that of the skin test, analyzed the effect of haemolysis degree on the antibody detection and described the relationship between the test readings and presence/absence of gross tuberculosis (TB) compatible lesions. Sensitivity of bPPD ELISA was 51% at a specificity of 96%. Depending on the cut-off value selected, the sensitivity of DPP VetTB ranged from 62 to 71%, while its specificity was 88-95%. In the subgroup of M. bovis-infected deer for which the skin test data were available (33 of 73); this method detected 76% of culture-positive animals, although the specificity of the intradermal test was not determined in this study. When the DPP VetTB and skin test data were combined, the resulting sensitivity obtained in this sub-group of M. bovis-infected deer increased to 97%. Gross pathology identified TB compatible lesions (TBL) in 89% culture-confirmed fallow deer. The infected animals with visible lesions had significantly higher readings in the DPP VetTB, but not in the bPPD ELISA. Only high levels of haemolysis decreased antibody test sensitivity and this effect was more evident for the bPPD ELISA. The results allowed inferring a number of management recommendations for rapid detection of MTC infection in live fallow deer and in surveys on hunter-harvested cervids. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Research Note The reliability of a field test kit for the detection and ...

    African Journals Online (AJOL)

    Research Note The reliability of a field test kit for the detection and the persistence of ... Open Access DOWNLOAD FULL TEXT ... The objectives were to test a field kit for practicality and reliability, to assess the spread of the bacteria among ...

  18. Random Gap Detection Test (RGDT) performance of individuals with central auditory processing disorders from 5 to 25 years of age.

    Science.gov (United States)

    Dias, Karin Ziliotto; Jutras, Benoît; Acrani, Isabela Olszanski; Pereira, Liliane Desgualdo

    2012-02-01

    The aim of the present study was to assess the auditory temporal resolution ability in individuals with central auditory processing disorders, to examine the maturation effect and to investigate the relationship between the performance on a temporal resolution test with the performance on other central auditory tests. Participants were divided in two groups: 131 with Central Auditory Processing Disorder and 94 with normal auditory processing. They had pure-tone air-conduction thresholds no poorer than 15 dB HL bilaterally, normal admittance measures and presence of acoustic reflexes. Also, they were assessed with a central auditory test battery. Participants who failed at least one or more tests were included in the Central Auditory Processing Disorder group and those in the control group obtained normal performance on all tests. Following the auditory processing assessment, the Random Gap Detection Test was administered to the participants. A three-way ANOVA was performed. Correlation analyses were also done between the four Random Gap Detection Test subtests data as well as between Random Gap Detection Test data and the other auditory processing test results. There was a significant difference between the age-group performances in children with and without Central Auditory Processing Disorder. Also, 48% of children with Central Auditory Processing Disorder failed the Random Gap Detection Test and the percentage decreased as a function of age. The highest percentage (86%) was found in the 5-6 year-old children. Furthermore, results revealed a strong significant correlation between the four Random Gap Detection Test subtests. There was a modest correlation between the Random Gap Detection Test results and the dichotic listening tests. No significant correlation was observed between the Random Gap Detection Test data and the results of the other tests in the battery. Random Gap Detection Test should not be administered to children younger than 7 years old because

  19. Rapid Quantitative Serological Test for Detection of Infection with Mycobacterium leprae, the Causative Agent of Leprosy

    Science.gov (United States)

    Balagon, Marivic F.; Maghanoy, Armi; Orcullo, Florenda M.; Cang, Marjorie; Dias, Ronaldo Ferreira; Collovati, Marco; Reed, Steven G.

    2014-01-01

    Leprosy remains an important health problem in a number of regions. Early detection of infection, followed by effective treatment, is critical to reduce disease progression. New sensitive and specific tools for early detection of infection will be a critical component of an effective leprosy elimination campaign. Diagnosis is made by recognizing clinical signs and symptoms, but few clinicians are able to confidently identify these. Simple tests to facilitate referral to leprosy experts are not widely available, and the correct diagnosis of leprosy is often delayed. In this report, we evaluate the performance of a new leprosy serological test (NDO-LID). As expected, the test readily detected clinically confirmed samples from patients with multibacillary (MB) leprosy, and the rate of positive results declined with bacterial burden. NDO-LID detected larger proportions of MB and paucibacillary (PB) leprosy than the alternative, the Standard Diagnostics leprosy test (87.0% versus 81.7% and 32.3% versus 6.5%, respectively), while also demonstrating improved specificity (97.4% versus 90.4%). Coupled with a new cell phone-based test reader platform (Smart Reader), the NDO-LID test provided consistent, objective test interpretation that could facilitate wider use in nonspecialized settings. In addition, results obtained from sera at the time of diagnosis, versus at the end of treatment, indicated that the quantifiable nature of this system can also be used to monitor treatment efficacy. Taken together, these data indicate that the NDO-LID/Smart Reader system can assist in the diagnosis and monitoring of MB leprosy and can detect a significant number of earlier-stage infections. PMID:24478496

  20. Performance of the Angio Detect™ in-clinic test kit for detection of Angiostrongylus vasorum infection in dog samples from Europe

    DEFF Research Database (Denmark)

    Liu, Jiayou; Schnyder, Manuela; Willesen, Jakob L.

    2017-01-01

    of the Angio Detect test kit by comparing Angio Detect testing results using serum or plasma samples with the results of Baermann-Wetzel testing using matched fecal samples. Samples from 214 dogs [with clinically suspected (N = 195) or diagnosed angiostrongylosis (N = 19)] were used for this evaluation......; sensitivity of the Angio Detect test was 97.1% (95%CI: 85.1%–99.9%). The Angio Detect test was negative for 177 of 179 samples that were negative by the Baermann-Wetzel test; specificity was 98.9% (95%CI: 96.0%–99.9%). In cross-reactivity testing, all 89 samples from dogs confirmed to be infected with other...... common nematodes (Dirofilaria immitis, D. repens, Crenosoma vulpis, hookworms, ascarids, or whipworms) were all negative for A. vasorum by the Angio Detect antigen test. Angio Detect provides a rapid and reliable method for diagnosis of A. vasorum in clinically suspected dogs at risk for infection...

  1. Detection of lipoarabinomannan as a diagnostic test for tuberculosis.

    OpenAIRE

    Sada, E; Aguilar, D; Torres, M; Herrera, T

    1992-01-01

    A coagglutination technique was established for the detection of lipoarabinomannan of Mycobacterium tuberculosis in human serum samples and evaluated for its utility in the diagnosis of tuberculosis at the Instituto Nacional de Enfermedades Respiratorias in Mexico City. The test had a sensitivity of 88% in patients with sputum-smear-positive active pulmonary tuberculosis. The sensitivity in patients with active pulmonary tuberculosis negative for acid-fast bacilli in sputum was 67%. Less favo...

  2. Spot test kit for explosives detection

    Science.gov (United States)

    Pagoria, Philip F; Whipple, Richard E; Nunes, Peter J; Eckels, Joel Del; Reynolds, John G; Miles, Robin R; Chiarappa-Zucca, Marina L

    2014-03-11

    An explosion tester system comprising a body, a lateral flow membrane swab unit adapted to be removeably connected to the body, a first explosives detecting reagent, a first reagent holder and dispenser operatively connected to the body, the first reagent holder and dispenser containing the first explosives detecting reagent and positioned to deliver the first explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body, a second explosives detecting reagent, and a second reagent holder and dispenser operatively connected to the body, the second reagent holder and dispenser containing the second explosives detecting reagent and positioned to deliver the second explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body.

  3. 25 CFR 39.409 - How does the OIEP Director ensure accountability?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false How does the OIEP Director ensure accountability? 39.409... EQUALIZATION PROGRAM Accountability § 39.409 How does the OIEP Director ensure accountability? (a) The Director of OIEP must ensure accountability in student counts and student transportation by doing all of the...

  4. BMVC test, an improved fluorescence assay for detection of malignant pleural effusions

    International Nuclear Information System (INIS)

    Lin, I-Ting; Tsai, Yu-Lin; Kang, Chi-Chih; Huang, Wei-Chun; Wang, Chiung-Lin; Lin, Mei-Ying; Lou, Pei-Jen; Shih, Jin-Yuan; Wang, Hao-Chien; Wu, Huey-Dong; Tsai, Tzu-Hsiu; Jan, I-Shiow; Chang, Ta-Chau

    2014-01-01

    The diagnosis of malignant pleural effusions is an important issue in the management of malignancy patients. Generally, cytologic examination is a routine diagnostic technique. However, morphological interpretation of cytology is sometimes inconclusive. Here an ancillary method named BMVC test is developed for rapid detection of malignant pleural effusion to improve the diagnostic accuracy at low cost. A simple assay kit is designed to collect living cells from clinical pleural effusion and a fluorescence probe, 3,6-Bis(1-methyl-4-vinylpyridinium) carbazole diiodide (BMVC), is used to illuminate malignant cells. The fluorescence intensity is quantitatively analyzed by ImageJ program. This method yields digital numbers for the test results without any grey zone or ambiguities in the current cytology tests due to intra-observer and inter-observer variability. Comparing with results from double-blind cytologic examination, this simple test gives a good discrimination between malignant and benign specimens with sensitivity of 89.4% (42/47) and specificity of 93.3% (56/60) for diagnosis of malignant pleural effusion. BMVC test provides accurate results in a short time period, and the digital output could assist cytologic examination to become more objective and clear-cut. This is a convenient ancillary tool for detection of malignant pleural effusions

  5. Evaluation of the KEMRI Hep-cell II test kit for detection of hepatitis B ...

    African Journals Online (AJOL)

    To evaluate the Hep-cell II test, blood samples were collected from blood donors and processed for detection of HBsAg using Hep-cell II based on the test principle and procedure outlined by the manufacturer. ELISA Axsym HBsAg test was used as golden standard. Of the 400 samples tested, 287 (71.8%) were positive by ...

  6. [Detection of anti-Leptospira antibodies in sera of patients in the latex agglutination test].

    Science.gov (United States)

    Volina, E G; Sarukhanova, L E; Iashina, N V; Prokopov, N I; Shkarlat, P E; Barysheva, I V

    2001-01-01

    The results of the preliminary evaluation of the sensitivity and specificity of the newly developed diagnostic test based on the determination of genus-specific antibodies to leptospires in the latex agglutination test, are presented. This test makes it possible to detect anti-Leptospira antibodies of any serogroup. The advantages of the developed test have been determined.

  7. Permeated defect detecting test method and device in reactor

    International Nuclear Information System (INIS)

    Sakurai, Yoshishige.

    1996-01-01

    The present invention provides a method of and a device capable of performing a test for entire inner surfaces of the reactor upon periodical inspection of a BWR type reactor while sufficiently taking countermeasures for radiation rays into consideration. Namely, the present invention comprises following steps. (1) A provisional step for taking a shroud head of a reactor core shroud and incore structural components above and below the shroud out of the reactor, discharging reactor water and water tightly closing openings such as reactor wall perforation holes, (2) a pretreatment step for washing exposed inner surfaces of the reactor and peeling deteriorated materials, (3) a first drying step for drying portions washed and peeled in the step (2), (4) a permeation step for applying a permeation liquid of a defect detecting medium on the exposed inner surfaces of the reactor, (5) a permeation liquid removing step for removing the an excess permeation liquid in the step (4), (6) a second drying step for drying corresponding portions after performing the step (5), and (7) a flaw detecting step for optically observing the corresponding portions after performing the step (6) and detecting flaws. (I.S.)

  8. Design of electronic measurement and quench detection equipment for the Current Lead Test facility Karlsruhe (CuLTKa)

    International Nuclear Information System (INIS)

    Hollik, Markus; Fietz, Walter H.; Fink, Stefan; Gehrlein, Mirko; Heller, Reinhard; Lange, Christian; Möhring, Tobias

    2013-01-01

    The Current Lead Test facility Karlsruhe (CuLTKa) is under construction at the Karlsruhe Institute of Technology (KIT) to perform acceptance tests of high temperature superconductor (HTS) current leads (CL). CuLTKa is in progress and present planning expects the completion in 2013. The data acquisition system is based on a modular design with electronic measurement and monitoring equipment covering a test voltage of 50 kV DC against ground. It provides plug-in units which enable temperature and voltage measurement at high voltage potential and in addition quench detection units which detect a loss of superconductivity reliably and quickly to avoid damage of the superconducting device under test. Prototype units for quench detection, temperature and voltage measurement have been successfully tested. Six temperature measurement units are already in use in the KIT test facility TOSKA and operated reliably during the acceptance tests of the HTS current leads for Wendelstein 7-X (W7-X) in 2011/2012. CuLTKa will be used first for 26 current leads which will be built in KIT for the fusion experiment JT-60SA. The present paper gives an overview of the design of the electronic measurement and quench detection equipment

  9. Self administered cognitive screening test (TYM) for detection of Alzheimer’s disease: cross sectional study

    Science.gov (United States)

    Pengas, George; Dawson, Kate; Clatworthy, Philip

    2009-01-01

    Objective To evaluate a cognitive test, the TYM (“test your memory”), in the detection of Alzheimer’s disease. Design Cross sectional study. Setting Outpatient departments in three hospitals, including a memory clinic. Participants 540 control participants aged 18-95 and 139 patients attending a memory clinic with dementia/amnestic mild cognitive impairment. Intervention Cognitive test designed to use minimal operator time and to be suitable for non-specialist use. Main outcome measures Performance of normal controls on the TYM. Performance of patients with Alzheimer’s disease on the TYM compared with age matched controls. Validation of the TYM with two standard tests (the mini-mental state examination (MMSE) and the Addenbrooke’s cognitive examination-revised (ACE-R)). Sensitivity and specificity of the TYM in the detection of Alzheimer’s disease. Results Control participants completed the TYM with an average score of 47/50. Patients with Alzheimer’s disease scored an average of 33/50. The TYM score shows excellent correlation with the two standard tests. A score of ≤42/50 had a sensitivity of 93% and specificity of 86% in the diagnosis of Alzheimer’s disease. The TYM was more sensitive in detection of Alzheimer’s disease than the mini-mental examination, detecting 93% of patients compared with 52% for the mini-mental state exxamination. The negative and positive predictive values of the TYM with the cut off of ≤42 were 99% and 42% with a prevalence of Alzheimer’s disease of 10%. Thirty one patients with non-Alzheimer dementias scored an average of 39/50. Conclusions The TYM can be completed quickly and accurately by normal controls. It is a powerful and valid screening test for the detection of Alzheimer’s disease. PMID:19509424

  10. Detection of person misfit in computerized adaptive tests with polytomous items

    NARCIS (Netherlands)

    van Krimpen-Stoop, Edith; Meijer, R.R.

    2000-01-01

    Item scores that do not fit an assumed item response theory model may cause the latent trait value to be estimated inaccurately. For computerized adaptive tests (CAT) with dichotomous items, several person-fit statistics for detecting nonfitting item score patterns have been proposed. Both for

  11. Wide area change detection with satellite imagery for locating underground nuclear testing

    International Nuclear Information System (INIS)

    Canty, M.J.; Jasani, B.; Schlittenhardt, J.

    2001-01-01

    With the advent of high resolution optical imagery from commercial earth observation satellites, the use of remote sensing data for verification of nuclear non-proliferation agreements is becoming increasingly attractive. Non-governmental organizations are routinely publishing high-quality imagery of sensitive nuclear installations round the world, and international verification authorities, such as the International Atomic Energy Agency (IAEA) or the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), will also want to make use, directly or indirectly, of this additional open source of information. Exact location of the sites of underground nuclear explosions is a task eminently suited to satellite imagery. Here both moderate resolutions for detecting signals in very large testing ranges as well as high resolution images for exact interpretation play important roles. We describe in our paper a particularly sensitive change detection procedure for bitemporal, multispectral satellite imagery which can be used to locate the spall zone of underground nuclear explosions with commercial satellite imagery. The method is based on the multivariate alteration detection (MAD) technique of Nielsen et al. Linear combinations of the spectral channels in two images of the same scene are chosen so as to minimize their positive correlation. This leads to a series of difference images - the so-called MAD components - which are mutually orthogonal (uncorrelated) and ordered according to decreasing variance in their pixel intensities. Since interesting changes in man-made structures may contribute minimally to the overall variance (as the latter may be dominated for instance by seasonal vegetation differences) it is often the case that such changes turn up in a higher order MAD component. This is because they will be uncorrelated with seasonal vegetation changes, stochastic image noise or other major contributions to the overall change signal. This in fact is one of the

  12. Ensuring microbiological safety of commercial eggs by gamma irradiation

    International Nuclear Information System (INIS)

    Hammad, A.A; Swailam, H.M.; Abd El-Rahim, E.A.; Shallan, M.A; Aly, W.F.

    2009-01-01

    Egg shell sanitizing practices are necessary to improve microbiological safety of fresh eggs. In this work, fifteen fresh eggs samples of each (balady, white and brown eggs) were collected from different local supermarkets to evaluate their microbiological quality. The results indicated that balady eggs were higher in microbial population in comparison with the two other varieties. Salmonella spp. was detected in 9 (60%) samples of balady eggs. The effect of gamma irradiation at dose of 0,2,3 and 4 kGy on microbiological quality of balady eggs during storage at 4± 1 deg c for 35 days as well as on total cholesterol , ph, and total carotenoids contents were also investigated. The results showed that irradiation at 3 kGy reduced total aerobic bacterial counts. Whereas completely eliminated coliform bacteria, E.coli and salmonella spp. Total cholesterol and total carotenoids were decreased in yolk egg. irradiation dose of 3 kGy were efficient and sufficient for ensuring safety, maintain quality and extend shelf-life of balady eggs

  13. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    Science.gov (United States)

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  14. Colorimetric test-systems for creatinine detection based on composite molecularly imprinted polymer membranes.

    Science.gov (United States)

    Sergeyeva, T A; Gorbach, L A; Piletska, E V; Piletsky, S A; Brovko, O O; Honcharova, L A; Lutsyk, O D; Sergeeva, L M; Zinchenko, O A; El'skaya, A V

    2013-04-03

    An easy-to-use colorimetric test-system for the efficient detection of creatinine in aqueous samples was developed. The test-system is based on composite molecularly imprinted polymer (MIP) membranes with artificial receptor sites capable of creatinine recognition. A thin MIP layer was created on the surface of microfiltration polyvinylidene fluoride (PVDF) membranes using method of photo-initiated grafting polymerization. The MIP layer was obtained by co-polymerization of a functional monomer (e.g. 2-acrylamido-2-methyl-1-propanesulfonic acid, itaconic acid or methacrylic acid) with N, N'-methylenebisacrylamide as a cross-linker. The choice of the functional monomer was based on the results of computational modeling. The creatinine-selective composite MIP membranes were used for measuring creatinine in aqueous samples. Creatinine molecules were selectively adsorbed by the MIP membranes and quantified using color reaction with picrates. The intensity of MIP membranes staining was proportional to creatinine concentration in an analyzed sample. The colorimetric test-system based on the composite MIP membranes was characterized with 0.25 mM detection limit and 0.25-2.5mM linear dynamic range. Storage stability of the MIP membranes was estimated as at least 1 year at room temperature. As compared to the traditional methods of creatinine detection the developed test-system is characterized by simplicity of operation, small size and low cost. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Development and Test of Methods for Fault Detection and Isolation

    DEFF Research Database (Denmark)

    Jørgensen, R.B.

    Almost all industrial systemns are automated to ensure optimal production both in relation to energy consumtion and safety to equipment and humans. All working parts are individually subject to faults. This can lead to unacceptable economic loss or injury to people. This thesis deals with a monit......Almost all industrial systemns are automated to ensure optimal production both in relation to energy consumtion and safety to equipment and humans. All working parts are individually subject to faults. This can lead to unacceptable economic loss or injury to people. This thesis deals...

  16. Evaluation of the dimethylglyoxime stick test for the detection of nickel

    DEFF Research Database (Denmark)

    Menné, T; Andersen, Klaus Ejner; Kaaber, K

    1987-01-01

    The value of the dimethylglyoxime stick test for the detection of nickel was determined for 54 randomly purchased metal objects designed for prolonged skin contact, and for 15 metal alloys of known composition. Surface nickel content was determined by EDAX analysis (energy dispersive X-ray) and n...

  17. Analytical strategy for the detection of antibiotic residues in sheep and goat’s milk

    International Nuclear Information System (INIS)

    Beltrán, M.C.; Althaus, R.L.; Molina, A.; Berruga, M.I.; Molina, M.P.

    2015-01-01

    The use of antibiotics to treat mastitis and other infectious diseases in dairy sheep and goats is a widespread practice nowadays that can, when not properly applied, result in the contamination of the milk supply. Spanish legislation establishes the control of the presence of antibiotic residues in sheep and goat’s milk using screening methods that detect, at least, beta-lactam drugs. Microbial inhibitor tests using Geobacillus stearothermophilus var. calidolactis and specific receptor-binding assays are most widely employed for this purpose. The detection rates of screening tests routinely used in Spain have been calculated considering the frequency of use of veterinary drugs commonly applied in ovine and caprine livestock to treat and prevent mastitis as well as the test sensitivity toward these substances at safety levels. In general, the use of a single test allows detecting 62.8-82.4% of the antibiotics employed. For sheep milk, the total detection range achieved with microbial tests was significantly higher than that reached with rapid receptor tests. However, no significant differences between the two types of methods were found when goat's milk was analysed. In both types of milk, the simultaneous use of two screening tests with a different analytical basis increases the total detection range significantly, reaching values ≥ 90% in some cases (81.5-90.1% for sheep and 84.7-92.6% for goats). However, the periodical use of screening tests able to detect quinolones, macrolides or aminoglycosides would be recommended to carry out more efficient screening and ensure the safety of milk and dairy products from sheep and goats. (Author)

  18. Analytical strategy for the detection of antibiotic residues in sheep and goat’s milk

    Energy Technology Data Exchange (ETDEWEB)

    Beltrán, M.C.; Althaus, R.L.; Molina, A.; Berruga, M.I.; Molina, M.P.

    2015-07-01

    The use of antibiotics to treat mastitis and other infectious diseases in dairy sheep and goats is a widespread practice nowadays that can, when not properly applied, result in the contamination of the milk supply. Spanish legislation establishes the control of the presence of antibiotic residues in sheep and goat’s milk using screening methods that detect, at least, beta-lactam drugs. Microbial inhibitor tests using Geobacillus stearothermophilus var. calidolactis and specific receptor-binding assays are most widely employed for this purpose. The detection rates of screening tests routinely used in Spain have been calculated considering the frequency of use of veterinary drugs commonly applied in ovine and caprine livestock to treat and prevent mastitis as well as the test sensitivity toward these substances at safety levels. In general, the use of a single test allows detecting 62.8-82.4% of the antibiotics employed. For sheep milk, the total detection range achieved with microbial tests was significantly higher than that reached with rapid receptor tests. However, no significant differences between the two types of methods were found when goat's milk was analysed. In both types of milk, the simultaneous use of two screening tests with a different analytical basis increases the total detection range significantly, reaching values ≥ 90% in some cases (81.5-90.1% for sheep and 84.7-92.6% for goats). However, the periodical use of screening tests able to detect quinolones, macrolides or aminoglycosides would be recommended to carry out more efficient screening and ensure the safety of milk and dairy products from sheep and goats. (Author)

  19. Analytical strategy for the detection of antibiotic residues in sheep and goat’s milk

    Directory of Open Access Journals (Sweden)

    M. Carmen Beltrán

    2015-03-01

    Full Text Available The use of antibiotics to treat mastitis and other infectious diseases in dairy sheep and goats is a widespread practice nowadays that can, when not properly applied, result in the contamination of the milk supply. Spanish legislation establishes the control of the presence of antibiotic residues in sheep and goat’s milk using screening methods that detect, at least, beta-lactam drugs. Microbial inhibitor tests using Geobacillus stearothermophilus var. calidolactis and specific receptor-binding assays are most widely employed for this purpose. The detection rates of screening tests routinely used in Spain have been calculated considering the frequency of use of veterinary drugs commonly applied in ovine and caprine livestock to treat and prevent mastitis as well as the test sensitivity toward these substances at safety levels. In general, the use of a single test allows detecting 62.8-82.4% of the antibiotics employed. For sheep milk, the total detection range achieved with microbial tests was significantly higher than that reached with rapid receptor tests. However, no significant differences between the two types of methods were found when goat’s milk was analysed. In both types of milk, the simultaneous use of two screening tests with a different analytical basis increases the total detection range significantly, reaching values ≥ 90% in some cases (81.5-90.1% for sheep and 84.7-92.6% for goats. However, the periodical use of screening tests able to detect quinolones, macrolides or aminoglycosides would be recommended to carry out more efficient screening and ensure the safety of milk and dairy products from sheep and goats.

  20. Accuracy of Clinical Tests in Detecting Disk Herniation and Nerve Root Compression in Subjects With Lumbar Radicular Symptoms.

    Science.gov (United States)

    Ekedahl, Harald; Jönsson, Bo; Annertz, Mårten; Frobell, Richard B

    2018-04-01

    To investigate the accuracy of 3 commonly used neurodynamic tests (slump test, straight-leg raise [SLR] test, femoral neurodynamic test) and 2 clinical assessments to determine radiculopathy (radiculopathy I, 1 neurologic sign; radiculopathy II, 2 neurologic signs corresponding to 1 specific nerve root) in detecting magnetic resonance imaging (MRI) findings (extrusion, subarticular nerve root compression, and foraminal nerve root compression). Validity study. Secondary care. We included subjects (N=99; mean age, 58y; 54% women) referred for epidural steroid injection because of lumbar radicular symptoms who had positive clinical and MRI findings. Positive clinical findings included the slump test (n=67), SLR test (n=50), femoral neurodynamic test (n=7), radiculopathy I (n=70), and radiculopathy II (n=33). Positive MRI findings included extrusion (n=27), subarticular nerve compression (n=14), and foraminal nerve compression (n=25). Not applicable. Accuracy of clinical tests in detecting MRI findings was evaluated using sensitivity, specificity, and receiver operating characteristics analysis with area under the curve (AUC). The slump test had the highest sensitivity in detecting extrusion (.78) and subarticular nerve compression (1.00), but the respective specificity was low (.36 and .38). Radiculopathy I was most sensitive in detecting foraminal nerve compression (.80) but with low specificity (.34). Only 1 assessment had a concurrent high sensitivity and specificity (ie, radiculopathy II) in detecting subarticular nerve compression (.71 and .73, respectively). The AUC for all tests in detecting extrusion, subarticular nerve compression, and foraminal nerve compression showed ranges of .48 to .60, .63 to .82, and .33 to .57, respectively. In general, the investigated neurodynamic tests or assessments for radiculopathy lacked diagnostic accuracy. The slump test was the most sensitive test, while radiculopathy II was the most specific test. Most interestingly, no

  1. Detecting dementia in patients with normal neuropsychological screening by Short Smell Test and Palmo-Mental Reflex Test: an observational study.

    Science.gov (United States)

    Streit, Sven; Limacher, Andreas; Zeller, Andreas; Bürge, Markus

    2015-07-25

    General practitioners (GPs) are in best position to suspect dementia. Mini-Mental State Examination (MMSE) and Clock Drawing Test (CDT) are widely used. Additional neurological tests may increase the accuracy of diagnosis. We aimed to evaluate diagnostic ability to detect dementia with a Short Smell Test (SST) and Palmo-Mental Reflex (PMR) in patients whose MMSE and CDT are normal, but who show signs of cognitive dysfunction. This was a 3.5-year cross-sectional observational study in the Memory Clinic of the University Department of Geriatrics in Bern, Switzerland. Participating patients with normal MMSE (>26 points) and CDT (>5 points) were referred by GPs because they suspected dementia. All were examined according to a standardized protocol. Diagnosis of dementia was based on DSM-IV TR criteria. We used SST and PMR to determine if they accurately detected dementia. In our cohort, 154 patients suspected of dementia had normal MMSE and CDT test results. Of these, 17 (11%) were demented. If SST or PMR were abnormal, sensitivity was 71% (95% CI 44-90%), and specificity 64% (95% CI 55-72%) for detecting dementia. If both tests were abnormal, sensitivity was 24% (95% CI 7-50%), but specificity increased to 93% (95% CI 88-97%). Patients suspected of dementia, but with normal MMSE and CDT results, may benefit if SST and PMR are added as diagnostic tools. If both SST and PMR are abnormal, this is a red flag to investigate these patients further, even though their negative neuropsychological screening results.

  2. The detection limits of antimicrobial agents in cow's milk by a simple Yoghurt Culture Test.

    Science.gov (United States)

    Mohsenzadeh, M; Bahrainipour, A

    2008-09-15

    The aim of this study was to study performance of Yoghurt Culture Test (YCT) in the detection of antimicrobial residues in milk. For this purpose, the sensitivity of YCT for 15 antibiotics were determined. For each drug, 8 concentrations were tested. The detection limits of YCT at 2.5 h and 4 h incubation were determined (microg kg(-1)): 15 and 37.5, penicillin G; 4 and 5, ampicillin; 5 and 7.5, amoxycillin; 100 and 200, cephalexin; 80 and 100, cefazoline; 100 and 200, oxytetracycline; 500 and 100, chlortetracycline; 100 and 200, tetracycline; 150 and 200, doxycycline; 200 and 400, sulphadimidine; 500 and 1000, gentamycin; 1000 and 1500, spectinomycin; 400 and 500, erythromycin; 50 and 100, tylosin; 5000 and 10000, chloramphenicol. The YCT detection limits at 2.5 h incubation for ampicillin, cephalexin, tetracycline, oxytetracycline and tylosin are similar to those obtained as Maximum Residue Limit (MRL) according to Regulation 2377/90 EEC as set out by the European Union. In addition the detection limits of YCT for some antibiotics were lower than some of microbial inhibitor test.

  3. Field Test Kit for Gun Residue Detection; TOPICAL

    International Nuclear Information System (INIS)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue

  4. Ensuring a Safe Technological Revolution

    Science.gov (United States)

    2016-12-01

    much lower, and the performance gained can dramatically reduce life -cycle costs. Validated cost data are scarce, and accurate AM cost models need to be...reduce costs, minimize obsolescence issues and improve both capability and readi- ness across the entire life cycle of naval systems—including both the...of naval weapon systems. The Navy is actively engaging its various communi- ties to align needs and ensure that AM can be safely acceler- ated and

  5. The detection of tightly closed flaws by nondestructive testing (NDT) methods. [fatigue crack formation in aluminum alloy test specimens

    Science.gov (United States)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.

    1975-01-01

    Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.

  6. 40 CFR 53.66 - Test procedure: Volatility test.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedure: Volatility test. 53.66... Characteristics of Class II Equivalent Methods for PM2.5 § 53.66 Test procedure: Volatility test. (a) Overview. This test is designed to ensure that the candidate method's losses due to volatility when sampling semi...

  7. Bronchial provocation testing does not detect exercise-induced laryngeal obstruction.

    Science.gov (United States)

    Walsted, Emil Schwarz; Hull, James H; Sverrild, Asger; Porsbjerg, Celeste; Backer, Vibeke

    2017-01-02

    Exercise-induced laryngeal obstruction (EILO) is a key differential diagnosis for asthma in the presence of exertional respiratory symptoms. Continuous laryngoscopy during exercise (CLE), the current gold standard diagnostic test for EILO, has practical limitations. We aimed to establish if inspiratory flow data obtained during standard bronchoprovocation testing, to establish the presence of extra-thoracic hyper-responsiveness, may prove diagnostic for EILO and thus preclude requirement for CLE testing. We consecutively evaluated 37 adult subjects with exertional dyspnea and possible asthma referred over 6 months. All subjects received comprehensive assessment including a detailed clinical evaluation; pulmonary function testing, indirect and direct bronchial provocation testing, and CLE testing. Out of 37 subjects, moderate or severe EILO was diagnosed in 8 subjects (22%, all female) while 5 (14%) had both asthma and EILO. There was no correlation between degree of EILO during CLE and mean decrease in forced inspiratory flow (%FIF 50 ) obtained during neither the Methacholine (r = -0.15; p = 0.38) nor Mannitol (r = 0.04; p = 0.84) provocation tests. Inspiratory flow parameters obtained during bronchoprovocation tests did not reliably detect EILO. It remains that CLE is an important and key investigation modality in establishing a secure diagnosis of EILO.

  8. Noninvasive Prenatal Testing and Incidental Detection of Occult Maternal Malignancies.

    Science.gov (United States)

    Bianchi, Diana W; Chudova, Darya; Sehnert, Amy J; Bhatt, Sucheta; Murray, Kathryn; Prosen, Tracy L; Garber, Judy E; Wilkins-Haug, Louise; Vora, Neeta L; Warsof, Stephen; Goldberg, James; Ziainia, Tina; Halks-Miller, Meredith

    2015-07-14

    Understanding the relationship between aneuploidy detection on noninvasive prenatal testing (NIPT) and occult maternal malignancies may explain results that are discordant with the fetal karyotype and improve maternal clinical care. To evaluate massively parallel sequencing data for patterns of copy-number variations that might prospectively identify occult maternal malignancies. Case series identified from 125,426 samples submitted between February 15, 2012, and September 30, 2014, from asymptomatic pregnant women who underwent plasma cell-free DNA sequencing for clinical prenatal aneuploidy screening. Analyses were conducted in a clinical laboratory that performs DNA sequencing. Among the clinical samples, abnormal results were detected in 3757 (3%); these were reported to the ordering physician with recommendations for further evaluation. NIPT for fetal aneuploidy screening (chromosomes 13, 18, 21, X, and Y). Detailed genome-wide bioinformatics analysis was performed on available sequencing data from 8 of 10 women with known cancers. Genome-wide copy-number changes in the original NIPT samples and in subsequent serial samples from individual patients when available are reported. Copy-number changes detected in NIPT sequencing data in the known cancer cases were compared with the types of aneuploidies detected in the overall cohort. From a cohort of 125,426 NIPT results, 3757 (3%) were positive for 1 or more aneuploidies involving chromosomes 13, 18, 21, X, or Y. From this set of 3757 samples, 10 cases of maternal cancer were identified. Detailed clinical and sequencing data were obtained in 8. Maternal cancers most frequently occurred with the rare NIPT finding of more than 1 aneuploidy detected (7 known cancers among 39 cases of multiple aneuploidies by NIPT, 18% [95% CI, 7.5%-33.5%]). All 8 cases that underwent further bioinformatics analysis showed unique patterns of nonspecific copy-number gains and losses across multiple chromosomes. In 1 case, blood was

  9. Periodic Application of Concurrent Error Detection in Processor Array Architectures. PhD. Thesis -

    Science.gov (United States)

    Chen, Paul Peichuan

    1993-01-01

    Processor arrays can provide an attractive architecture for some applications. Featuring modularity, regular interconnection and high parallelism, such arrays are well-suited for VLSI/WSI implementations, and applications with high computational requirements, such as real-time signal processing. Preserving the integrity of results can be of paramount importance for certain applications. In these cases, fault tolerance should be used to ensure reliable delivery of a system's service. One aspect of fault tolerance is the detection of errors caused by faults. Concurrent error detection (CED) techniques offer the advantage that transient and intermittent faults may be detected with greater probability than with off-line diagnostic tests. Applying time-redundant CED techniques can reduce hardware redundancy costs. However, most time-redundant CED techniques degrade a system's performance.

  10. Formative Evaluation of EFNEP Curriculum: Ensuring the Eating Smart • Being Active Curriculum Is Theory Based

    Science.gov (United States)

    Natker, Elana; Baker, Susan S.; Auld, Garry; McGirr, Kathryn; Sutherland, Barbara; Cason, Katherine L.

    2015-01-01

    The project reported here served to assess a curriculum for EFNEP to ensure theory compliance and content validity. Adherence to Adult Learning Theory and Social Cognitive Theory tenets was determined. A curriculum assessment tool was developed and used by five reviewers to assess initial and revised versions of the curriculum. T-tests for…

  11. Molecular testing of human papillomavirus in cervical specimens

    International Nuclear Information System (INIS)

    Gazzaz, Faten Salah B.

    2007-01-01

    Objective was to improve the diagnosis of cervical neoplasia by early detection of human papillomavirus (HPV) in uterine cervix, by adding molecular testing of HPV using hybrid capture 2 (HC2) and polymerase chain reaction (PCR) tests to Papanicoalou (Pap) test. One hundred women were enrolled in this study. The mean age (mean+-SD) was 41.97+- 8.76 years and range was 27-65 years. All women had undergone cervical cytological screening with cervical cytology, HPV DNA testing by HC2 and PCR, during the period from January to December 2006, at King Abdul-Aziz University Hospital (KAAUH) and King Fahd research Center, Jeddah, Saudi Arabia. The results were obtained by HC2 for detection of HPV were 5(5%) high-risk HPV, one low-risk HPV (1%) and 94(94%) negative cases. The PCR detected only 4(4%) cases. Using the HC2 test as a reference, sensitivity, specificity, positive predictive, negative predictive values and accuracy of base line Pap were 50, 85, 17.7, 96.4 and 83%; of final Pap smear were 100, 96.8, 66.7, 100, and 97% and for PCR were 66.7, 100, 100, 97.9 and 98%. The Pap test was repeated within a year for patients with abnormal Pap test with positive HPV DNA. Combined screening by cytology and HPV testing using both HC2 and PCR sensitively detects women with existing disease. The absence of HPV DNA provides reassurance that patients are unlikely to develop cancer for several years. We suggest using Pap with HC2 and PCR in screening programs to ensure that women with the double negative result at baseline might safely be screened at longer intervals. (author)

  12. False star detection and isolation during star tracking based on improved chi-square tests.

    Science.gov (United States)

    Zhang, Hao; Niu, Yanxiong; Lu, Jiazhen; Yang, Yanqiang; Su, Guohua

    2017-08-01

    The star sensor is a precise attitude measurement device for a spacecraft. Star tracking is the main and key working mode for a star sensor. However, during star tracking, false stars become an inevitable interference for star sensor applications, which may result in declined measurement accuracy. A false star detection and isolation algorithm in star tracking based on improved chi-square tests is proposed in this paper. Two estimations are established based on a Kalman filter and a priori information, respectively. The false star detection is operated through adopting the global state chi-square test in a Kalman filter. The false star isolation is achieved using a local state chi-square test. Semi-physical experiments under different trajectories with various false stars are designed for verification. Experiment results show that various false stars can be detected and isolated from navigation stars during star tracking, and the attitude measurement accuracy is hardly influenced by false stars. The proposed algorithm is proved to have an excellent performance in terms of speed, stability, and robustness.

  13. Gaps-in-Noise test: gap detection thresholds in 9-year-old normal-hearing children.

    Science.gov (United States)

    Marculino, Carolina Finetti; Rabelo, Camila Maia; Schochat, Eliane

    2011-12-01

    To establish the standard criteria for the Gaps-in-Noise (GIN) test in 9-year-old normal-hearing children; to obtain the mean gap detection thresholds; and to verify the influence of the variables gender and ear on the gap detection thresholds. Forty normal-hearing individuals, 20 male and 20 female, with ages ranging from 9 years to 9 years and 11 months, were evaluated. The procedures performed were: anamnesis, audiological evaluation, acoustic immittance measures (tympanometry and acoustic reflex), Dichotic Digits Test, and GIN test. The results obtained were statistically analyzed. The results revealed similar performance of right and left ears in the population studied. There was also no difference regarding the variable gender. In the subjects evaluated, the mean gap detection thresholds were 4.4 ms for the right ear, and 4.2 ms for the left ear. The values obtained for right and left ear, as well as their standard deviations, can be used as standard criteria for 9-year-old children, regardless of ear or gender.

  14. A Framework for Fully Automated Performance Testing for Smart Buildings

    DEFF Research Database (Denmark)

    Markoska, Elena; Johansen, Aslak; Lazarova-Molnar, Sanja

    2018-01-01

    , setup of performance tests has been manual and labor-intensive and has required intimate knowledge of buildings’ complexity and systems. The emergence of the concept of smart buildings has provided an opportunity to overcome this restriction. In this paper, we propose a framework for automated......A significant proportion of energy consumption by buildings worldwide, estimated to ca. 40%, has yielded a high importance to studying buildings’ performance. Performance testing is a mean by which buildings can be continuously commissioned to ensure that they operate as designed. Historically...... performance testing of smart buildings that utilizes metadata models. The approach features automatic detection of applicable performance tests using metadata queries and their corresponding instantiation, as well as continuous commissioning based on metadata. The presented approach has been implemented...

  15. Predicament in detection and reporting of extended spectrum beta lactamase production in routine antibiotic susceptibility testing

    International Nuclear Information System (INIS)

    Butt, T.; Butt, E.; Raza, S.

    2017-01-01

    This descriptive and cross-sectional study was planned to determine the dilemma of inadvertent detection of extended spectrum beta lactamase (ESBL) production in Enterobacteriaceaewhen using inhibition zone size of antibiotic disks of Cefotaxime or Aztreonam in routine antibiotic susceptibility testing as recommended by Clinical Laboratory Standards Institute (CLSI). Screening and double disk tests were adopted as per CLSI. Escherichia coli ATCC 25922 was used as control strain. Among total specimens of 5346, there were 348 isolates of Escherichia coli(n=235), Klebsiella pneumonia (n=92), Klebsiella oxytoca(n=3) or Proteus mirabilus(n=18). The screening method recommended by CLSI significantly falsely detected ESBL production in 79 (32.3%) isolates (p<0.0001). ESBL detection is important as its frequency is high and treatment of the infection varies with the presence and absence of ESBL. To avoid false reporting, proper phenotypic detection of ESBL confirmatory method-like double-disk synergy test, should be used routinely. (author)

  16. Non-invasive prenatal testing: a review of international implementation and challenges

    Science.gov (United States)

    Allyse, Megan; Minear, Mollie A; Berson, Elisa; Sridhar, Shilpa; Rote, Margaret; Hung, Anthony; Chandrasekharan, Subhashini

    2015-01-01

    Noninvasive prenatal genetic testing (NIPT) is an advance in the detection of fetal chromosomal aneuploidies that analyzes cell-free fetal DNA in the blood of a pregnant woman. Since its introduction to clinical practice in Hong Kong in 2011, NIPT has quickly spread across the globe. While many professional societies currently recommend that NIPT be used as a screening method, not a diagnostic test, its high sensitivity (true positive rate) and specificity (true negative rate) make it an attractive alternative to the serum screens and invasive tests currently in use. Professional societies also recommend that NIPT be accompanied by genetic counseling so that families can make informed reproductive choices. If NIPT becomes more widely adopted, States will have to implement regulation and oversight to ensure it fits into existing legal frameworks, with particular attention to returning fetal sex information in areas where sex-based abortions are prevalent. Although there are additional challenges for NIPT uptake in the developing world, including the lack of health care professionals and infrastructure, the use of NIPT in low-resource settings could potentially reduce the need for skilled clinicians who perform invasive testing. Future advances in NIPT technology promise to expand the range of conditions that can be detected, including single gene disorders. With these advances come questions of how to handle incidental findings and variants of unknown significance. Moving forward, it is essential that all stakeholders have a voice in crafting policies to ensure the ethical and equitable use of NIPT across the world. PMID:25653560

  17. Does Refactoring of Test Smells Induce Fixing Flaky Tests?

    NARCIS (Netherlands)

    Palomba, F.; Zaidman, A.E.

    2017-01-01

    Regression testing is a core activity that allows developers to ensure that source code changes do not introduce bugs. An important prerequisite then is that test cases are deterministic. However, this is not always the case as some tests suffer from socalled flakiness. Flaky tests have serious

  18. Review: Diagnostic accuracy of PCR-based detection tests for Helicobacter Pylori in stool samples.

    Science.gov (United States)

    Khadangi, Fatemeh; Yassi, Maryam; Kerachian, Mohammad Amin

    2017-12-01

    Although different methods have been established to detect Helicobacter pylori (H. pylori) infection, identifying infected patients is an ongoing challenge. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for stool PCR test in the diagnosis of H. pylori infection. In this study, a systematic review and meta-analysis were carried out on various sources, including MEDLINE, Web of Sciences, and the Cochrane Library from April 1, 1999, to May 1, 2016. This meta-analysis adheres to the guidelines provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses report (PRISMA Statement). The clinical value of DNA stool PCR test was based on the pooled false positive, false negative, true positive, and true negative of different genes. Twenty-six of 328 studies identified met the eligibility criteria. Stool PCR test had a performance of 71% (95% CI: 68-73) sensitivity, 96% (95% CI: 94-97) specificity, and 65.6 (95% CI: 30.2-142.5) diagnostic odds ratio (DOR) in diagnosis of H. pylori. The DOR of genes which showed the highest performance of stool PCR tests was as follows: 23S rRNA 152.5 (95% CI: 55.5-418.9), 16S rRNA 67.9 (95%CI: 6.4-714.3), and glmM 68.1 (95%CI: 20.1-231.7). The sensitivity and specificity of stool PCR test are relatively in the same spectrum of other diagnostic methods for the detection of H. pylori infection. In descending order of significance, the most diagnostic candidate genes using PCR detection were 23S rRNA, 16S rRNA, and glmM. PCR for 23S rRNA gene which has the highest performance could be applicable to detect H. pylori infection. © 2017 John Wiley & Sons Ltd.

  19. A novel automatic molecular test for detection of multidrug resistance tuberculosis in sputum specimen: A case control study.

    Science.gov (United States)

    Li, Qiang; Ou, Xi C; Pang, Yu; Xia, Hui; Huang, Hai R; Zhao, Bing; Wang, Sheng F; Zhao, Yan L

    2017-07-01

    MiniLab tuberculosis (ML TB) assay is a new automatic diagnostic tool for diagnosis of multidrug resistance tuberculosis (MDR-TB). This study was conducted with aims to know the performance of this assay. Sputum sample from 224 TB suspects was collected from tuberculosis suspects seeking medical care at Beijing Chest hospital. The sputum samples were directly used for smear and ML TB test. The left sputum sample was used to conduct Xpert MTB/RIF, Bactec MGIT culture and drug susceptibility test (DST). All discrepancies between the results from DST, molecular and phenotypic methods were confirmed by DNA Sequencing. The sensitivity and specificity of ML TB test for detecting MTBC from TB suspects were 95.1% and 88.9%, respectively. The sensitivity for smear negative TB suspects was 64.3%. For detection of RIF resistance, the sensitivity and specificity of ML TB test were 89.2% and 95.7%, respectively. For detection of INH resistance, the sensitivity and specificity of ML TB test were 78.3% and 98.1%, respectively. ML TB test showed similar performance to Xpert MTB/RIF for detection of MTBC and RIF resistance. In addition, ML TB also had good performance for INH resistance detection. Copyright © 2017. Published by Elsevier Ltd.

  20. Pressurized water reactor monitoring. Study of detection, diagnostic and estimation (least squares and filtering) methods

    International Nuclear Information System (INIS)

    Gillet, M.

    1986-07-01

    This thesis presents a study for the surveillance of the Primary circuit water inventory of a pressurized water reactor. A reference model is developed for the development of an automatic system ensuring detection and real-time diagnostic. The methods to our application are statistical tests and adapted a pattern recognition method. The estimation of the detected anomalies is treated by the least square fit method, and by filtering. A new projected optimization method with superlinear convergence is developed in this framework, and a segmented linearization of the model is introduced, in view of a multiple filtering. 46 refs [fr

  1. (indigenous) education ensure effective gender mainstreaming in ...

    African Journals Online (AJOL)

    Leaving no one behind: can (indigenous) education ensure effective gender ... in the distribution of socio-economic and political benefits, depict that additional ... of gender equality and equity and explores in different ways the relationships ...

  2. Manufacturing and testing flexible microfluidic devices with optical and electrical detection mechanisms

    NARCIS (Netherlands)

    Ivan, M.G.; Vivet, F.; Meinders, E.R.

    2010-01-01

    Flexible microfluidic devices made of poly(dimethylsiloxane) (PDMS) were manufactured by soft lithography, and tested in detection of ionic species using optical absorption spectroscopy and electrical measurements. PDMS was chosen due to its flexibility and ease of surface modification by exposure

  3. Application of functional IDDQ testing in a VLIW processor towards detection of aging degradation

    NARCIS (Netherlands)

    Kerkhoff, Hans G.; Zhao, Yong

    2015-01-01

    In this paper, functional IDDQ testing has been applied for a 90nm VLIW processor to effectively detect aging degradation. This technique can provide health data for reliability evaluation as used in e.g. prognostic software for lifetime prediction. The test environment for validation, implementing

  4. The Relationship between Test Preparation and State Test Performance: Evidence from the Measure of Effective Teaching (MET) Project

    Science.gov (United States)

    Li, Hongli; Xiong, Yao

    2018-01-01

    The passage of the NCLB Act enhanced accountability policies in the United States, and standardized testing became prevalent as a policy tool to ensure accountability in K-12 education. Given the high stakes of state administered accountability tests, more school teachers have adopted test-preparation strategies to ensure satisfactory student…

  5. SigmaPlot 2000, Version 6.00, SPSS Inc. Computer Software Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    HURLBUT, S.T.

    2000-10-24

    SigmaPlot is a vendor software product used in conjunction with the supercritical fluid extraction Fourier transform infrared spectrometer (SFE-FTIR) system. This product converts the raw spectral data to useful area numbers. SigmaPlot will be used in conjunction with procedure ZA-565-301, ''Determination of Moisture by Supercritical Fluid Extraction and Infrared Detection.'' This test plan will be performed in conjunction with or prior to HNF-6936, ''HA-53 Supercritical Fluid Extraction System Acceptance Test Plan'', to perform analyses for water. The test will ensure that the software can be installed properly and will manipulate the analytical data correctly.

  6. Wireless Network Penetration Testing and Security Auditing

    Directory of Open Access Journals (Sweden)

    Wang Shao-Long

    2016-01-01

    Full Text Available IEEE802.11 wireless wireless networks have security issues that are vulnerable to a variety of attacks. Due to using radio to transport data, attackers can bypass firewalls, sniff sensitive information, intercept packets and send malicious packets. Security auditing and penetration testing is expected to ensure wireless networks security. The contributions of this work are analyzed the vulnerability and types of attacks pertaining to IEEE 802.11 WLAN, performed well known attacks in a laboratory environment to conduct penetration tests to confirm whether our wireless network is hackable or not. WAIDPS is configured as auditing tool to view wireless attacks, such as WEP/WPA/WPA2 cracking, rouge access points, denial of service attack. WAIDPS is designed to detect wireless intrusion with additional features. Penetration testing and auditing will mitigate the risk and threatening to protect WALN.

  7. Amalgamation of Anomaly-Detection Indices for Enhanced Process Monitoring

    KAUST Repository

    Harrou, Fouzi; Sun, Ying; Khadraoui, Sofiane

    2016-01-01

    Accurate and effective anomaly detection and diagnosis of modern industrial systems are crucial for ensuring reliability and safety and for maintaining desired product quality. Anomaly detection based on principal component analysis (PCA) has been

  8. An evaluation of adequacy of water policy stipulation in ensuring ...

    African Journals Online (AJOL)

    An evaluation of adequacy of water policy stipulation in ensuring water security in the context of climate change. ... Ethiopian Journal of Environmental Studies and Management ... The aim of the study was to establish how responsive the Water Policy (2010) is to ensure water security in the context of climate change.

  9. Preventive testing and leakage detection in pipe-lines of steam condensers and generators of a PWR type reactor

    International Nuclear Information System (INIS)

    Canalini, A.; Carvalho, N.C. de

    1985-01-01

    The non-destructive methods: Spum, Helium and Hydrostatic used in leakage detection in condenser pipelines for PWR type reactors are presented. The time, costs, sensitivity, resources necessary and personnel development factors are considered to choose adequated method, in function of nuclear power plant conditions. The leakage tests are applied in pressurized systems or vacuum. Eddy Current testing is used in condensers and steam generators aiming to avoid leakage in these equipments. The spume testing for leakage detection in condenser pipelines - which operation - and hydrostatic testing for leakage detection through reaming with shutdown - were most efficients. The Helium testing applied in pressurized systems or submitted to vacuum systems presented satisfactory results. The Eddy Current testing in condenser and steam generator pipelines reached desired objective, reducing leakage in the first and preserving the integrity in the second. (M.C.K.) [pt

  10. DYNAMIC SOFTWARE TESTING MODELS WITH PROBABILISTIC PARAMETERS FOR FAULT DETECTION AND ERLANG DISTRIBUTION FOR FAULT RESOLUTION DURATION

    Directory of Open Access Journals (Sweden)

    A. D. Khomonenko

    2016-07-01

    Full Text Available Subject of Research.Software reliability and test planning models are studied taking into account the probabilistic nature of error detection and discovering. Modeling of software testing enables to plan the resources and final quality at early stages of project execution. Methods. Two dynamic models of processes (strategies are suggested for software testing, using error detection probability for each software module. The Erlang distribution is used for arbitrary distribution approximation of fault resolution duration. The exponential distribution is used for approximation of fault resolution discovering. For each strategy, modified labeled graphs are built, along with differential equation systems and their numerical solutions. The latter makes it possible to compute probabilistic characteristics of the test processes and states: probability states, distribution functions for fault detection and elimination, mathematical expectations of random variables, amount of detected or fixed errors. Evaluation of Results. Probabilistic characteristics for software development projects were calculated using suggested models. The strategies have been compared by their quality indexes. Required debugging time to achieve the specified quality goals was calculated. The calculation results are used for time and resources planning for new projects. Practical Relevance. The proposed models give the possibility to use the reliability estimates for each individual module. The Erlang approximation removes restrictions on the use of arbitrary time distribution for fault resolution duration. It improves the accuracy of software test process modeling and helps to take into account the viability (power of the tests. With the use of these models we can search for ways to improve software reliability by generating tests which detect errors with the highest probability.

  11. Development of molecular tests for the detection of ILAR and latent viruses in fruit trees.

    Science.gov (United States)

    Roussel, S; Kummert, J; Dutrecq, O; Lepoivre, P; Jijakli, M H

    2004-01-01

    The detection throughout the year of latent and ILAR viruses in fruit tress by classical serological tests appear to be unreliable. We have developed RT-PCR tests for a reliable detection of latent and ILAR viruses in fruit trees. These assays were then simplified to allow the direct use of crude plant extracts instead of total RNA preparations, and the analyses of pooled samples. In this way, such RT-PCR protocols are suitable for a routine diagnosis of latent and ILAR viruses in fruit tree certification.

  12. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    Science.gov (United States)

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  13. Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.

    Science.gov (United States)

    Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua

    2015-12-15

    Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Fast microwave detection system for coherent synchrotron radiation study at KEK: Accelerator test facility

    International Nuclear Information System (INIS)

    Aryshev, A.; Araki, S.; Karataev, P.; Naito, T.; Terunuma, N.; Urakawa, J.

    2007-01-01

    A fast room temperature microwave detection system based on the Schottky Barrier-diode detector was created at the KEK ATF (Accelerator Test Facility). It was tested using Coherent Synchrotron Radiation (CSR) generated by the 1.28 GeV electron beam in the damping ring. The speed performance of the detection system was checked by observing the CSR from a multi-bunch (2.8 ns bunch separation time) beam. The theoretical estimations of CSR power yield from an edge of bending magnet as well as new injection tuning method are presented. A very high sensitivity of CSR power yield to the longitudinal electron distribution in a bunch is discussed

  15. Statistical Hypothesis Testing using CNN Features for Synthesis of Adversarial Counterexamples to Human and Object Detection Vision Systems

    Energy Technology Data Exchange (ETDEWEB)

    Raj, Sunny [Univ. of Central Florida, Orlando, FL (United States); Jha, Sumit Kumar [Univ. of Central Florida, Orlando, FL (United States); Pullum, Laura L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ramanathan, Arvind [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-01

    Validating the correctness of human detection vision systems is crucial for safety applications such as pedestrian collision avoidance in autonomous vehicles. The enormous space of possible inputs to such an intelligent system makes it difficult to design test cases for such systems. In this report, we present our tool MAYA that uses an error model derived from a convolutional neural network (CNN) to explore the space of images similar to a given input image, and then tests the correctness of a given human or object detection system on such perturbed images. We demonstrate the capability of our tool on the pre-trained Histogram-of-Oriented-Gradients (HOG) human detection algorithm implemented in the popular OpenCV toolset and the Caffe object detection system pre-trained on the ImageNet benchmark. Our tool may serve as a testing resource for the designers of intelligent human and object detection systems.

  16. Detecting Chloride Contamination of Objects and Buildings – Evaluating a New Testing Process

    Directory of Open Access Journals (Sweden)

    Lynda Skipper

    2018-02-01

    Full Text Available Soluble salts play a key factor in damage to a variety of materials, including stone, ceramics and metals. Particularly, salt contamination can lead to weakening of porous materials through salt crystallisation events, and increases the rate of metal corrosion. Over time, this results in physical damage to affected objects and buildings. It is therefore important to be able to monitor the salt content of materials, in order to understand levels of salt contamination and the potential for damage to occur. This research discusses the further development of the testing method for surface chlorides originally proposed by Piechota and Drake Piechota (2016 in their article “A simple survey kit for chloride detection on cuneiform tablets and other collections”. It introduces new and revised steps into the original protocol in order to make the achieved results semi-quantifiable, as well as identifying the limits of detection of the test kit. A comparison to alternative testing methods showed that comparable results were achievable using this methodology. The revised methodology was tested for efficacy on a range of salt contaminated objects, as well as on samples from buildings.

  17. A fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection.

    Science.gov (United States)

    Di Nardo, F; Anfossi, L; Giovannoli, C; Passini, C; Goftman, V V; Goryacheva, I Y; Baggiani, C

    2016-04-01

    A fluorescent immunochromatographic strip test (ICST) based on the use of Quantum Dots (QD) was developed and applied to detect fumonisins in maize samples. A limit of detection for fumonisin B1 of 2.8 µg L(-1) was achieved, with an analytical working range of 3-350 µg L(-1), corresponding to 30-3500 µg kg(-1) in maize flour samples, according with the extraction procedure. The time required to perform the analysis was 22 min, including sample preparation. Recovery values in the range from 91.4% to 105.4% with coefficients of variation not exceeding 5% were obtained for fortified and naturally contaminated maize flour samples. To evaluate the possible improvements due to the use of QD for ICST technology, we performed a direct comparison of the proposed QD-ICST to a gold nanoparticles- and a chemiluminescent-ICST previously developed for fumonisins detection, in which the same immunoreagents were employed. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    Science.gov (United States)

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  19. Methods for ensuring compliance with regulatory requirements: regulators and operators

    International Nuclear Information System (INIS)

    Fleischmann, A.W.

    1989-01-01

    Some of the methods of ensuring compliance with regulatory requirements contained in various radiation protection documents such as Regulations, ICRP Recommendations etc. are considered. These include radiation safety officers and radiation safety committees, personnel monitoring services, dissemination of information, inspection services and legislative power of enforcement. Difficulties in ensuring compliance include outmoded legislation, financial and personnel constraints

  20. Final report on the UKAEA defect detection trials on test pieces 3 and 4. December 1982

    International Nuclear Information System (INIS)

    Lock, D.L.; Cowburn, K.J.

    1983-03-01

    The report follows ND-R-845(R) which described the scope, inspection procedures and results of the defect detection trials on test pieces 3 and 4. The work has been aimed at assessing the ability of non-destructive testing techniques, to detect and size defects near the clad/base metal interface of a flat piece and the inner radius of a PWR inlet nozzle. Following the destructive examination of the test pieces at Ispra, the true sizes of the intended defects are now known. These sizes are compared with that intended and the performance of the inspection teams reviewed. (author)

  1. Ensuring Microbiological Safety of Fresh Eggs by Using Gamma Irradiation

    International Nuclear Information System (INIS)

    Hammad, A. A.; Swailam, H.M.; Aly, W. F.

    2008-01-01

    Egg shell sanitizing practices are necessary to improve microbiological safety of fresh eggs. In this work, fifteen fresh eggs samples of each (Balady, White and Brown eggs) were collected from different local supermarkets to evaluate their microbiological quality. The results indicated that Balady eggs were higher in microbial population in comparison with the two other varieties. Salmonella spp. was detected in 9 (60%) samples of Balady eggs. The effect of gamma irradiation at dose of 0, 2, 3 and 4 kGy on microbiological quality of Balady eggs during storage at 4±1 degree C for 35 days was studied. The effects of irradiation and storage on total cholesterol, and total carotenoids contents in Balady eggs were also investigated. The results showed that irradiation at 3 kGy reduced total aerobic bacterial counts. Coliform bacteria, E. coli and Salmonella spp. were completely eliminated. Total cholesterol and total carotenoids were decreased in yolk egg as a result of irradiation. Treated Balady eggs with irradiation dose of 3 kGy were efficient and sufficient for ensuring safety, maintain quality and extend shelf-life.

  2. Toothpick test: a methodology for the detection of RR soybean plants1

    Directory of Open Access Journals (Sweden)

    Fabiana Mota da Silva

    Full Text Available Due to the large increase in the area cultivated with genetically modified soybean in Brazil, it has become necessary to determine methods that are fast and efficient for detecting these cultivars. The aim of this work was to test the efficiency of the toothpick method in the detection of RR soybean plants, as well as to distinguish between cultivars, for sensitivity caused by herbicide. Ten transgenic soybean cultivars, resistant to the active ingredient glyphosate, and ten conventional soybean cultivars were used. Toothpicks soaked in glyphosate were applied to all the plants at stage V6 and evaluations were made at 2, 4, 6, 8 and 10 days after application (DAA. The effects of the glyphosate on the cultivars, and the symptoms of phytotoxicity caused in the transgenic plants were evaluated by means of grading scales. The toothpick test is effective in identifying RR soybean cultivars and also in separating them into groups by sensitivity to the symptoms caused by the glyphosate.

  3. AFNOR validation of Premi Test, a microbiological-based screening tube-test for the detection of antimicrobial residues in animal muscle tissue.

    Science.gov (United States)

    Gaudin, Valerie; Juhel-Gaugain, Murielle; Morétain, Jean-Pierre; Sanders, Pascal

    2008-12-01

    Premi Test contains viable spores of a strain of Bacillus stearothermophilus which is sensitive to antimicrobial residues, such as beta-lactams, tetracyclines, macrolides and sulphonamides. The growth of the strain is inhibited by the presence of antimicrobial residues in muscle tissue samples. Premi Test was validated according to AFNOR rules (French Association for Normalisation). The AFNOR validation was based on the comparison of reference methods (French Official method, i.e. four plate test (FPT) and the STAR protocol (five plate test)) with the alternative method (Premi Test). A preliminary study was conducted in an expert laboratory (Community Reference Laboratory, CRL) on both spiked and incurred samples (field samples). Several method performance criteria (sensitivity, specificity, relative accuracy) were estimated and are discussed, in addition to detection capabilities. Adequate agreement was found between the alternative method and the reference methods. However, Premi Test was more sensitive to beta-lactams and sulphonamides than the FPT. Subsequently, a collaborative study with 11 laboratories was organised by the CRL. Blank and spiked meat juice samples were sent to participants. The expert laboratory (CRL) statistically analysed the results. It was concluded that Premi Test could be used for the routine determination of antimicrobial residues in muscle of different animal origin with acceptable analytical performance. The detection capabilities of Premi Test for beta-lactams (amoxicillin, ceftiofur), one macrolide (tylosin) and tetracycline were at the level of the respective maximum residue limits (MRL) in muscle samples or even lower.

  4. Airborne Turbulence Detection and Warning ACLAIM Flight Test Results

    Science.gov (United States)

    Hannon, Stephen M.; Bagley, Hal R.; Soreide, Dave C.; Bowdle, David A.; Bogue, Rodney K.; Ehernberger, L. Jack

    1999-01-01

    The Airborne Coherent Lidar for Advanced Inflight Measurements (ACLAIM) is a NASA/Dryden-lead program to develop and demonstrate a 2 micrometers pulsed Doppler lidar for airborne look-ahead turbulence detection and warning. Advanced warning of approaching turbulence can significantly reduce injuries to passengers and crew aboard commercial airliners. The ACLAIM instrument is a key asset to the ongoing Turbulence component of NASA's Aviation Safety Program, aimed at reducing the accident rate aboard commercial airliners by a factor of five over the next ten years and by a factor of ten over the next twenty years. As well, the advanced turbulence warning capability can prevent "unstarts" in the inlet of supersonic aircraft engines by alerting the flight control computer which then adjusts the engine to operate in a less fuel efficient, and more turbulence tolerant, mode. Initial flight tests of the ACLAIM were completed in March and April of 1998. This paper and presentation gives results from these initial flights, with validated demonstration of Doppler lidar wind turbulence detection several kilometers ahead of the aircraft.

  5. An improved AE detection method of rail defect based on multi-level ANC with VSS-LMS

    Science.gov (United States)

    Zhang, Xin; Cui, Yiming; Wang, Yan; Sun, Mingjian; Hu, Hengshan

    2018-01-01

    In order to ensure the safety and reliability of railway system, Acoustic Emission (AE) method is employed to investigate rail defect detection. However, little attention has been paid to the defect detection at high speed, especially for noise interference suppression. Based on AE technology, this paper presents an improved rail defect detection method by multi-level ANC with VSS-LMS. Multi-level noise cancellation based on SANC and ANC is utilized to eliminate complex noises at high speed, and tongue-shaped curve with index adjustment factor is proposed to enhance the performance of variable step-size algorithm. Defect signals and reference signals are acquired by the rail-wheel test rig. The features of noise signals and defect signals are analyzed for effective detection. The effectiveness of the proposed method is demonstrated by comparing with the previous study, and different filter lengths are investigated to obtain a better noise suppression performance. Meanwhile, the detection ability of the proposed method is verified at the top speed of the test rig. The results clearly illustrate that the proposed method is effective in detecting rail defects at high speed, especially for noise interference suppression.

  6. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  7. MO-FG-202-07: Real-Time EPID-Based Detection Metric For VMAT Delivery Errors

    International Nuclear Information System (INIS)

    Passarge, M; Fix, M K; Manser, P; Stampanoni, M F M; Siebers, J V

    2016-01-01

    Purpose: To create and test an accurate EPID-frame-based VMAT QA metric to detect gross dose errors in real-time and to provide information about the source of error. Methods: A Swiss cheese model was created for an EPID-based real-time QA process. The system compares a treatmentplan- based reference set of EPID images with images acquired over each 2° gantry angle interval. The metric utilizes a sequence of independent consecutively executed error detection Methods: a masking technique that verifies infield radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment to quantify rotation, scaling and translation; standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each test were determined. For algorithm testing, twelve different types of errors were selected to modify the original plan. Corresponding predictions for each test case were generated, which included measurement-based noise. Each test case was run multiple times (with different noise per run) to assess the ability to detect introduced errors. Results: Averaged over five test runs, 99.1% of all plan variations that resulted in patient dose errors were detected within 2° and 100% within 4° (∼1% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 91.5% were detected by the system within 2°. Based on the type of method that detected the error, determination of error sources was achieved. Conclusion: An EPID-based during-treatment error detection system for VMAT deliveries was successfully designed and tested. The system utilizes a sequence of methods to identify and prevent gross treatment delivery errors. The system was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of errors in real-time and indicate the error

  8. MO-FG-202-07: Real-Time EPID-Based Detection Metric For VMAT Delivery Errors

    Energy Technology Data Exchange (ETDEWEB)

    Passarge, M; Fix, M K; Manser, P [Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern (Switzerland); Stampanoni, M F M [Institute for Biomedical Engineering, ETH Zurich, and PSI, Villigen (Switzerland); Siebers, J V [Department of Radiation Oncology, University of Virginia, Charlottesville, VA (United States)

    2016-06-15

    Purpose: To create and test an accurate EPID-frame-based VMAT QA metric to detect gross dose errors in real-time and to provide information about the source of error. Methods: A Swiss cheese model was created for an EPID-based real-time QA process. The system compares a treatmentplan- based reference set of EPID images with images acquired over each 2° gantry angle interval. The metric utilizes a sequence of independent consecutively executed error detection Methods: a masking technique that verifies infield radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment to quantify rotation, scaling and translation; standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each test were determined. For algorithm testing, twelve different types of errors were selected to modify the original plan. Corresponding predictions for each test case were generated, which included measurement-based noise. Each test case was run multiple times (with different noise per run) to assess the ability to detect introduced errors. Results: Averaged over five test runs, 99.1% of all plan variations that resulted in patient dose errors were detected within 2° and 100% within 4° (∼1% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 91.5% were detected by the system within 2°. Based on the type of method that detected the error, determination of error sources was achieved. Conclusion: An EPID-based during-treatment error detection system for VMAT deliveries was successfully designed and tested. The system utilizes a sequence of methods to identify and prevent gross treatment delivery errors. The system was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of errors in real-time and indicate the error

  9. Increasing the flexibility of the LANCE cAMP detection kit.

    Science.gov (United States)

    Hunter, Morag Rose; Glass, Michelle

    2015-01-01

    The detection of cAMP signalling is a common endpoint in the study of G-protein coupled receptors. A number of commercially available kits enable easy detection of cAMP. These kits are based on competition for a cAMP binding site on an antibody or cAMP binding protein and as such have a limited dynamic range. Here, we describe the optimisation of the commercially-available LANCE cAMP detection kit (PerkinElmer) to enable detection in cell lysates. This kit has been designed for use with live cells, with detection reagents applied to cells without wash steps. The standard protocol therefore requires that all assay reagents are compatible with the antibody and the final fluorescent detection stage, limiting the range of assay media and test compounds that can be utilised. The entire experiment must be repeated if cAMP levels fall outside the limited dynamic range. Here we describe a modified protocol that enables the assay to be performed on cell lysates, thereby overcoming these limitations. In this modified protocol, cells are stimulated for a cAMP response in standard media/buffers, washed and then lysed. The cell lysate is then assayed using a modified protocol for the LANCE cAMP detection kit. Samples were tested for stability following a freeze-thaw cycle. The modified LANCE cAMP detection protocol gives a reproducible measurement of cAMP in cell lysate. Lysate samples remain stable when stored at -80°C. Separating the stimulation and detection phases of this cAMP assay allows a vast array of cell stimulation conditions to be tested. The lysate-modified protocol for the LANCE cAMP detection kit therefore increases the flexibility, versatility and convenience of the assay. As samples are insensitive to freeze-thaw, it enables retesting of samples under different dilution conditions to ensure that all samples remain within the dynamic range of the standard curve. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Laser-induced fluorescence detection platform for point-of-care testing

    Science.gov (United States)

    Berner, Marcel; Hilbig, Urs; Schubert, Markus B.; Gauglitz, Günter

    2017-08-01

    Point-of-care testing (POCT) devices for continuous low-cost monitoring of critical patient parameters require miniaturized and integrated setups for performing quick high-sensitivity analyses, away from central clinical laboratories. This work presents a novel and promising laser-induced fluorescence platform for measurements in direct optical test formats that leads towards such powerful POCT devices based on fluorescence-labeled immunoassays. Ultimate sensitivity of thin film photodetectors, integrated with microfluidics, and a comprehensive optimization of all system components aim at low-level signal detection in the targeted biosensor application. The setup acquires fluorescence signals from the volume of a microfluidic channel. An innovative sandwiching process forms a flow channel in the microfluidic chips by embedding laser-cut double-sided adhesive tapes. The custom fit of amorphous silicon based photodiode arrays to the geometry of the flow channel enables miniaturization, fully adequate for POCT devices. A free-beam laser excitation with line focus provides excellent alignment stability, allows for easy and reliable swapping of the disposable microfluidic chips, and therewith greatly improves the ease of use of the resulting integrated device. As a proof-of-concept of this novel in-volume measurement approach, the limit of detection for the dye DY636-COOH in pure water as a model fluorophore is examined and found to be 26 nmol l-1 .

  11. A Robust Semi-Parametric Test for Detecting Trait-Dependent Diversification.

    Science.gov (United States)

    Rabosky, Daniel L; Huang, Huateng

    2016-03-01

    Rates of species diversification vary widely across the tree of life and there is considerable interest in identifying organismal traits that correlate with rates of speciation and extinction. However, it has been challenging to develop methodological frameworks for testing hypotheses about trait-dependent diversification that are robust to phylogenetic pseudoreplication and to directionally biased rates of character change. We describe a semi-parametric test for trait-dependent diversification that explicitly requires replicated associations between character states and diversification rates to detect effects. To use the method, diversification rates are reconstructed across a phylogenetic tree with no consideration of character states. A test statistic is then computed to measure the association between species-level traits and the corresponding diversification rate estimates at the tips of the tree. The empirical value of the test statistic is compared to a null distribution that is generated by structured permutations of evolutionary rates across the phylogeny. The test is applicable to binary discrete characters as well as continuous-valued traits and can accommodate extremely sparse sampling of character states at the tips of the tree. We apply the test to several empirical data sets and demonstrate that the method has acceptable Type I error rates. © The Author(s) 2015. Published by Oxford University Press, on behalf of the Society of Systematic Biologists. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Detection of foreign objects using bobbin probe eddy current test

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hee Sung; Kweon, Young Ho; Lee, Dong Ha; Shin, Wook Jo; Yim, Chan Ki [ECT Group, Sae-An Engineering Corporation, Seoul (Korea, Republic of)

    2016-08-15

    Residual foreign objects at the secondary side (top of the tubesheet and tube support plates) of a steam generator are likely to cause a leak by causing wear in the tube. The extent of wear is significantly affected by the material, shape, and size of the foreign object, and the corrosion properties of the tube. The presence of foreign objects at the top of the tubesheet and tube support plates has been identified using remote visual inspection methods such as the foreign object search and retrieval and eddy current test (ECT). The detection of the residual foreign object at the secondary side of a steam generator has limitations that depend on the material properties and the condition of contact with the tube. In this study, which is vertical and horizontal from the upper tubesheet, the corresponding bobbin ECT signals were collected and analyzed to measure its ability to detect foreign objects.

  13. Strategies for detection of transfusion-transmitted viruses eluding identification by conventional serologic tests. I

    International Nuclear Information System (INIS)

    Neurath, A.R.; Strick, N.

    1983-01-01

    The unavailability of serological tests for detection of several not yet characterized infectious agents transmitted by blood transfusion or by blood products prompted the development of alternative tests based on utilization of labeled nucleic acid probes specific for genomes of each of these agents. The prerequisite for the preparation of such probes is the demonstration in human plasma of nucleic acid sequences distinct from those present in host DNA or in genes of already characterized viruses occurring in plasma of infected individuals. To accomplish this, ultrasensitive tests for nucleic acids not dependent on their base sequence are needed. The authors describe a radioimmunoassay (RIA) for picogram quantities of DNA. Plasma (serum) specimens are treated with proteinase K in the presence of sodium dodecyl sulfate and extracted with phenol. Nucleic acids are precipitated with ethanol in the presence of dextran (mol.wt. approx. 5X10 5 ) as carrier. Subsequently, DNA from the redissolved samples is adsorbed onto polylysine-coated wells of microtiter plates and detected by a double-antibody RIA using anti-DNA autoantibodies from NZB/NZW mice and 125 I-labelled antibodies to mouse immunoglobulins. DNA which did not hybridize with human DNA was detected by this method in sera containing hepatitis B virus used as a model system. (Auth.)

  14. Change Detection in High-Resolution Remote Sensing Images Using Levene-Test and Fuzzy Evaluation

    Science.gov (United States)

    Wang, G. H.; Wang, H. B.; Fan, W. F.; Liu, Y.; Liu, H. J.

    2018-04-01

    High-resolution remote sensing images possess complex spatial structure and rich texture information, according to these, this paper presents a new method of change detection based on Levene-Test and Fuzzy Evaluation. It first got map-spots by segmenting two overlapping images which had been pretreated, extracted features such as spectrum and texture. Then, changed information of all map-spots which had been treated by the Levene-Test were counted to obtain the candidate changed regions, hue information (H component) was extracted through the IHS Transform and conducted change vector analysis combined with the texture information. Eventually, the threshold was confirmed by an iteration method, the subject degrees of candidate changed regions were calculated, and final change regions were determined. In this paper experimental results on multi-temporal ZY-3 high-resolution images of some area in Jiangsu Province show that: Through extracting map-spots of larger difference as the candidate changed regions, Levene-Test decreases the computing load, improves the precision of change detection, and shows better fault-tolerant capacity for those unchanged regions which are of relatively large differences. The combination of Hue-texture features and fuzzy evaluation method can effectively decrease omissions and deficiencies, improve the precision of change detection.

  15. Advancing Evidence Based Policymaking and Regulation to Ensure ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Advancing Evidence Based Policymaking and Regulation to Ensure Greater ... which is Communications Policy Research South (CPRsouth), a yearly conference that ... policy intellectuals through tutorials for young scholars and internships.

  16. Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test.

    Science.gov (United States)

    Bregnbak, David; Johansen, Jeanne D; Jellesen, Morten S; Zachariae, Claus; Thyssen, Jacob P

    2015-11-01

    Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release at 0.5 ppm without interference from other pure metals, alloys, or leather. A market survey using the test showed no chromium(VI) release from work tools (0/100). However, chromium(VI) release from metal screws (7/60), one earring (1/50), leather shoes (4/100) and leather gloves (6/11) was observed. We found no false-positive test reactions. Confirmatory testing was performed with X-ray fluorescence (XRF) and spectrophotometrically on extraction fluids. The use of DPC as a colorimetric spot test reagent appears to be a good and valid test method for detecting the release of chromium(VI) ions from leather and metal articles. The spot test has the potential to become a valuable screening tool. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Ensuring long-term availability of TELEPERM XS

    International Nuclear Information System (INIS)

    Bock, H.-W.; Richter, S.

    1998-01-01

    With putting in operation the first digital TELEPERM XS I and C systems for functions important to safety in nuclear power plants, ensuring long-term availability and reliable operation of TELEPERM XS systems gains increasing importance. On the one hand, the modular structure of TELEPERM XS has already been optimized during system development such that the application-specific functions are independent of the version of hardware components and system software. On the other hand, hardware-independent, tool-based engineering procedures ensure that the application software of installed I and C systems can be flexibly adapted to modified plant requirements while at the same time the very high software quality is retained. Quality-assured procedures and an actively organized configuration management guarantee that the functionality and the availability of the I and C systems keep their qualified standard. This paper discusses aspects of the configuration management for TELEPERM XS I and C systems. (author)

  18. Toward Ensuring Health Equity

    DEFF Research Database (Denmark)

    Petkovic, Jennifer; Epstein, Jonathan; Buchbinder, Rachelle

    2015-01-01

    , the Evaluative Linguistic Framework for Questionnaires, developed to assess text quality of questionnaires. We also considered a study assessing cross-cultural adaptation with/without back-translation and/or expert committee. The results of this preconference work were presented to the equity working group......OBJECTIVE: The goal of the Outcome Measures in Rheumatology (OMERACT) 12 (2014) equity working group was to determine whether and how comprehensibility of patient-reported outcome measures (PROM) should be assessed, to ensure suitability for people with low literacy and differing cultures. METHODS......: The English, Dutch, French, and Turkish Health Assessment Questionnaires and English and French Osteoarthritis Knee and Hip Quality of Life questionnaires were evaluated by applying 3 readability formulas: Flesch Reading Ease, Flesch-Kincaid grade level, and Simple Measure of Gobbledygook; and a new tool...

  19. Start up test and technical problems encountered on N.S. Mutsu

    International Nuclear Information System (INIS)

    Osanai, M.; Tomiyama, E.

    1978-01-01

    Based on experience with other reactors in general, the commissioning trials on N.S. Mutsu leading to full power were planned to be undertaken in six phases covering various ranges of reactor output from zero to full power. The first phase of zero power tests was carried out successfully, but the ensuring phases of the trials had to be suspended on account of radiation leakage being detected. In order to determine the cause of this leakage, measurements were made of the radiation dose rate around the reactor. The present paper outlines the evolution of the zero-phase test, and the survey work undertaken immediately after the radiation leakage

  20. Comparison of IRT Likelihood Ratio Test and Logistic Regression DIF Detection Procedures

    Science.gov (United States)

    Atar, Burcu; Kamata, Akihito

    2011-01-01

    The Type I error rates and the power of IRT likelihood ratio test and cumulative logit ordinal logistic regression procedures in detecting differential item functioning (DIF) for polytomously scored items were investigated in this Monte Carlo simulation study. For this purpose, 54 simulation conditions (combinations of 3 sample sizes, 2 sample…

  1. Tests for detecting overdispersion in models with measurement error in covariates.

    Science.gov (United States)

    Yang, Yingsi; Wong, Man Yu

    2015-11-30

    Measurement error in covariates can affect the accuracy in count data modeling and analysis. In overdispersion identification, the true mean-variance relationship can be obscured under the influence of measurement error in covariates. In this paper, we propose three tests for detecting overdispersion when covariates are measured with error: a modified score test and two score tests based on the proposed approximate likelihood and quasi-likelihood, respectively. The proposed approximate likelihood is derived under the classical measurement error model, and the resulting approximate maximum likelihood estimator is shown to have superior efficiency. Simulation results also show that the score test based on approximate likelihood outperforms the test based on quasi-likelihood and other alternatives in terms of empirical power. By analyzing a real dataset containing the health-related quality-of-life measurements of a particular group of patients, we demonstrate the importance of the proposed methods by showing that the analyses with and without measurement error correction yield significantly different results. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Recall Tests Are Effective to Detect Mild Cognitive Impairment: A Systematic Review and Meta-analysis of 108 Diagnostic Studies.

    Science.gov (United States)

    Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S

    2017-09-01

    Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most

  3. Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle.

    Science.gov (United States)

    Karthik, K; Rathore, Rajesh; Thomas, Prasad; Arun, T R; Viswas, K N; Agarwal, R K; Manjunathachar, H V; Dhama, Kuldeep

    2014-01-01

    Brucella abortus, the major causative agent of abortion in cattle and a zoonotic pathogen, needs to be diagnosed at an early stage. Loop-mediated isothermal amplification (LAMP) test is easy to perform and also promising to be adapted at field level. To develop a LAMP assay for specific and rapid detection of B. abortus from clinical samples of cattle. LAMP primers were designed targeting BruAb2_0168 region using specific software tool and LAMP was optimized. The developed LAMP was tested for its specificity with 3 Brucella spp. and 11 other non-Brucella spp. Sensitivity of the developed LAMP was also carried out with known quantity of DNA. Cattle whole blood samples and aborted fetal stomach contents were collected and used for testing with developed LAMP assay and results were compared with polymerase chain reaction (PCR). The developed LAMP assay works at 61 °C for 60 min and the detection limit was observed to be 100-fold more than the conventional PCR that is commonly used for diagnosis of B. abortus. Clinical sensitivity and specificity of the developed LAMP assay was 100% when compared with Rose Bengal plate test and standard tube agglutination test. SYB® green dye I was used to visualize the result with naked eye. The novelty of the developed LAMP assay for specifically detecting B. abortus infection in cattle along with its inherent rapidness and high sensitivity can be employed for detecting this economically important pathogen of cattle at field level as well be exploited for screening of human infections.

  4. Development and Testing of an Air Fluorescence Imaging System for the Detection of Radiological Contamination

    International Nuclear Information System (INIS)

    Inrig, Elizabeth; Koslowsky, Vern; Andrews, Bob; Dick, Michael; Forget, Patrick; Ing, Harry; Hugron, Roger; Wong, Larry

    2011-01-01

    Detection of radionuclides emitting short-range radiation, such as α and low-energy β particles, has always presented a challenge, particularly when such radionuclides are dispersed over a wide area. In this situation, conventional detection methods require the area of interest to be surveyed using a fragile probe at very close range--a slow, error-prone, and potentially dangerous process that may take many hours for a single room. The instrument under development uses a novel approach by imaging radiation-induced fluorescence in the air surrounding a contaminated area, rather than detecting the radiation directly. A robust and portable system has been designed and built that will allow contaminated areas to be rapidly detected and delineated. The detector incorporates position-sensitive photo-multiplier tubes, UV filters, a fast electronic shutter and an aspherical phase mask that significantly increases the depth-of-field. Preliminary tests have been conducted using sealed 241 Am sources of varying activities and surface areas. The details of the instrument design will be described and the results of recent testing will be presented.

  5. EFFECTIVENESS OF TUBERCULOUS RECOMBINANT ALLERGEN SKIN TESTS FOR DETECTING TUBERCULOSIS IN CHILDREN AND ADOLESCENTS OF MOSCOW IN 2013

    Directory of Open Access Journals (Sweden)

    L. V. Slogotskaya

    2015-01-01

    Full Text Available Explanation. Mantoux test is used to detect the tuberculous infection; however, low specificity of this method results in a high rate of false positive responses due to cross-reactions of PPD (protein purified derivate antigens contained in many mycobacterial species and Bacillus Calmette-Guerin (BCG strains. New drug Diaskintest (DST — recombinant protein CFP10-ESAT6 produced by Escherichia coli BL21(DE3/pCFP-ESAT proved to be the best acceptable diagnostic drug. The article was aimed at studying effectiveness of tuberculous recombinant allergen tests for detecting tuberculosis in the children and adolescents, who were registered in Moscow in 2013. Methods. Mantoux tests were used to examine 1,420,100 persons; positive reactions were observed in 1,020,000 children and adolescents (71,8%; 131,361 (12.9% of them were examined using DSTs. Results. Positive reactions to DST were observed in 3,304 persons (2.5% of the persons with positive reactions to Mantoux test. The tuberculosis detection rate among the persons with positive reactions to Mantoux tests using 2TU PPD-L (Leningrad Research Institute of Vaccines and Serums is 0.13%, among the persons with positive reactions to DSTs — 4.9%, i.e. 40 times more often (p = 0.000. Post-tuberculosis alterations were detected in 169 persons: in 0.13% of the persons with positive reactions to Mantoux tests using 2TU PPD-L and in 5.1% of the persons with positive reactions to DSTs (p = 0.000. Conclusion. Cohort studies conducted in Moscow demonstrated high effectiveness of Diaskintests for detecting tuberculosis in children and adolescents. High sensitivity of the method helps to detect the overwhelming majority of the persons with tuberculosis.

  6. Comparative Evaluation of Seven Commercial Tests for Detection of Heterophile Antibody in Infectious Mononucleosis

    Directory of Open Access Journals (Sweden)

    Martin Skulnick

    1992-01-01

    Full Text Available Detection of heterophile antibodies in infectious mononucleosis is the most rapid and cost-effective method for confirming the clinical diagnosis of the disease. This study compared seven commercial test kits (the Oxoid Infectious Mononucleosis Kit [Oxoid Ltd], Immunoscan Im-Latex [Baxter Travenol], Mono-Latex [Wampole Laboratories], Monospot and Im Screen Test [Ortho Diagnostics], Immunoscan Im-RBC Test [Baxter Travenol], and Infectious Mononucleosis Test [NCS Diagnostics] to the Davidsohn differential test. All of the kits were shown to be acceptable for use, with specificities and sensitivities greater than 96.5% and 95.5%, respectively.

  7. Double-blind test program for astrometric planet detection with Gaia

    Science.gov (United States)

    Casertano, S.; Lattanzi, M. G.; Sozzetti, A.; Spagna, A.; Jancart, S.; Morbidelli, R.; Pannunzio, R.; Pourbaix, D.; Queloz, D.

    2008-05-01

    Aims: The scope of this paper is twofold. First, it describes the simulation scenarios and the results of a large-scale, double-blind test campaign carried out to estimate the potential of Gaia for detecting and measuring planetary systems. The identified capabilities are then put in context by highlighting the unique contribution that the Gaia exoplanet discoveries will be able to bring to the science of extrasolar planets in the next decade. Methods: We use detailed simulations of the Gaia observations of synthetic planetary systems and develop and utilize independent software codes in double-blind mode to analyze the data, including statistical tools for planet detection and different algorithms for single and multiple Keplerian orbit fitting that use no a priori knowledge of the true orbital parameters of the systems. Results: 1) Planets with astrometric signatures α≃ 3 times the assumed single-measurement error σ_ψ and period P≤ 5 yr can be detected reliably and consistently, with a very small number of false positives. 2) At twice the detection limit, uncertainties in orbital parameters and masses are typically 15-20%. 3) Over 70% of two-planet systems with well-separated periods in the range 0.2≤ P≤ 9 yr, astrometric signal-to-noise ratio 2≤α/σ_ψ≤ 50, and eccentricity e≤ 0.6 are correctly identified. 4) Favorable orbital configurations (both planets with P≤ 4 yr and α/σ_ψ≥ 10, redundancy over a factor of 2 in the number of observations) have orbital elements measured to better than 10% accuracy > 90% of the time, and the value of the mutual inclination angle i_rel determined with uncertainties ≤ 10°. 5) Finally, nominal uncertainties obtained from the fitting procedures are a good estimate of the actual errors in the orbit reconstruction. Extrapolating from the present-day statistical properties of the exoplanet sample, the results imply that a Gaia with σ_ψ = 8 μas, in its unbiased and complete magnitude-limited census of

  8. Performance of blue-yellow screening test for antimicrobial detection in ovine milk.

    Science.gov (United States)

    Linage, B; Gonzalo, C; Carriedo, J A; Asensio, J A; Blanco, M A; De La Fuente, L F; San Primitivo, F

    2007-12-01

    Drug residues in milk are important because of public health and industrial implications. The detection limits of 25 antimicrobial agents were determined by the blue-yellow screening method in ovine milk. For each drug, 8 concentrations were tested on 20 ovine milk samples from individual ewes in midlactation. Detection limits determined by means of logistic regression were below European Union maximum residue limits (EU-MRL) for penicillin G (3 to 4 microg/kg), ceftiofur (96 to 107 microg/kg), framycetin (720 to 781 microg/kg), neomycin (915 to 1,084 microg/kg), and tylosin (44 to 51 microg/kg). Detection limits for ampicillin (5 to 6 microg/kg), cloxacillin (33 to 42 microg/kg), cefoperazone (73 to 82 microg/kg), cefalexin (160 to 202 microg/kg), gentamycin (355 to 382 microg/kg), streptomycin (3,063 to 3,593 microg/kg), tilmicosin (109 to 131 microg/kg), erythromycin (444 to 522 microg/kg), spyramicin (1,106 to 1,346 microg/kg), sulfadimethoxine (101 to 119 microg/kg), sulfathiazole (122 to 151 microg/kg), sulfamethazine (309 to 328 microg/kg), sulfanilamide (1,750 to 2,674 microg/kg), tetracycline (233 to 257 microg/kg), oxytetracycline (398 to 501 microg/kg), doxycycline (323 to 419 microg/kg), chlortetracycline (3,331 to 3,989 microg/kg), danofloxacin (4.7 to 5.5 mg/kg), enrofloxacin (41 to 46 mg/kg), and flumequin (63 to 71 mg/kg) were higher than the EU-MRL. Although the blue-yellow method showed improved sensitivity compared with other tests studied in ovine milk, the performance of screening methods for detecting antimicrobial agents in milk of this species should be improved.

  9. Communication skills to ensure patient satisfaction.

    Science.gov (United States)

    Shendurnikar, Niranjan; Thakkar, Pareshkumar A

    2013-11-01

    Every pediatrician would want to satisfy their patients and their parents to sustain good practice, earn name and fame and simultaneously to avoid litigation in this era of consumer protection act. This can be achieved only by use of good communication skills. Today the patients demand time, information and want their questions to be answered. They expect politeness, empathy and human touch from doctors. Time constraints, arrogance, telephone calls, language barriers and cultural insensitivity are the important barriers to good communication. Research has shown that doctor, who undergoes training to acquire good communication skills, can better satisfy his patients. Good communication skill is an art which can be acquired or improved by putting conscious efforts in day to day practice. Such skills should also be incorporated as part of medical teaching curriculum. Asking open ended questions, effective listening, appropriate praise, providing enough information as part of advice and finally checking their understanding, are the key areas of communication during medical interview. During this process pediatrician should ensure to address the parental concerns, should empathize with parents and involve parents in decision making. This will not only ensure satisfaction of parents but also their adherence to the therapy and to the pediatrician.

  10. Modified forelimb grip strength test detects aging-associated physiological decline in skeletal muscle function in male mice.

    Science.gov (United States)

    Takeshita, Hikari; Yamamoto, Koichi; Nozato, Satoko; Inagaki, Tadakatsu; Tsuchimochi, Hirotsugu; Shirai, Mikiyasu; Yamamoto, Ryohei; Imaizumi, Yuki; Hongyo, Kazuhiro; Yokoyama, Serina; Takeda, Masao; Oguro, Ryosuke; Takami, Yoichi; Itoh, Norihisa; Takeya, Yasushi; Sugimoto, Ken; Fukada, So-Ichiro; Rakugi, Hiromi

    2017-02-08

    The conventional forelimb grip strength test is a widely used method to assess skeletal muscle function in rodents; in this study, we modified this method to improve its variability and consistency. The modified test had lower variability among trials and days than the conventional test in young C57BL6 mice, especially by improving the variabilities in male. The modified test was more sensitive than the conventional test to detect a difference in motor function between female and male mice, or between young and old male mice. When the modified test was performed on male mice during the aging process, reduction of grip strength manifested between 18 and 24 months of age at the group level and at the individual level. The modified test was similar to the conventional test in detecting skeletal muscle dysfunction in young male dystrophic mice. Thus, the modified forelimb grip strength test, with its improved validity and reliability may be an ideal substitute for the conventional method.

  11. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  12. Nucleic acid tests for the detection of alpha human papillomaviruses.

    Science.gov (United States)

    Poljak, Mario; Cuzick, Jack; Kocjan, Boštjan J; Iftner, Thomas; Dillner, Joakim; Arbyn, Marc

    2012-11-20

    Testing for high-risk types of alpha human papillomaviruses (HPV) is an invaluable part of clinical guidelines for cervical carcinoma screening, management and treatment. In this comprehensive inventory of commercial tests for detection of alpha-HPV, we identified at least 125 distinct HPV tests and at least 84 variants of the original tests. However, only a small subset of HPV tests has documented clinical performance for any of the standard HPV testing indications. For more than 75% of HPV tests currently on the market, no single publication in peer-reviewed literature can be identified. HPV tests that have not been validated and lack proof of reliability, reproducibility and accuracy should not be used in clinical management. Once incorporated in the lab, it is essential that the whole procedure of HPV testing is subject to continuous and rigorous quality assurance to avoid sub-optimal, potentially harmful practices. Manufacturers of HPV tests are urged to put more effort into evaluating their current and future products analytically, using international standards, and for clinical applications, using clinically validated endpoints. To assist with analytical validation, the World Health Organization is developing international standards for HPV types other than HPV16 and HPV18 and is planning development of external quality control panels specifically designed to be used for performance evaluation of current and future HPV tests. There is a need for more competitively priced HPV tests, especially for resource-poor countries, and uniform test validation criteria based on international standards should enable issuing more competitive and fair tender notices for purchasing. Automation systems allowing large-scale testing, as well as further increases in clinical performance, are the main needs in the further improvement of HPV tests. This article forms part of a special supplement entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine

  13. Salmonella detection in a microfluidic channel using orbiting magnetic beads

    Science.gov (United States)

    Ballard, Matt; Mills, Zachary; Owen, Drew; Hanasoge, Srinivas; Hesketh, Peter; Alexeev, Alexander

    2015-03-01

    We use three-dimensional simulations to model the detection of salmonella in a complex fluid sample in a microfluidic channel. Salmonella is captured using magnetic microbeads orbiting around soft ferromagnetic discs at the microchannel bottom subjected to a rotating external magnetic field. Numerical simulations are used to model the dynamics of salmonella and microbeads throughout the detection process. We examine the effect of the channel geometry on the salmonella capture, and the forces applied to the salmonella as it is dragged through the fluid after capture. Our findings guide the design of a lab-on-a-chip device to be used for detection of salmonella in food samples in a way that ensures that salmonella captured by orbiting microbeads are preserved until they can be extracted from the system for testing, and are not washed away by the fluid flow or damaged due to the experience of excessive stresses. Such a device is needed to detect bacteria at the food source and prevention of consumption of contaminated food, and also can be used for the detection of a variety of biomaterials of interest from complex fluid samples. Support from USDA and NSF is gratefully acknowledged.

  14. Development of a fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in dogs

    NARCIS (Netherlands)

    Schallig, H. D. F. H.; Schoone, G. J.; Beijer, E. G. M.; Kroon, C. C. M.; Hommers, M.; Ozbel, Y.; Ozensoy, S.; da Silva, E. S.; Cardoso, L. M.; da Silva, E. D.

    2002-01-01

    A fast agglutination screening test (FAST) for the detection of anti-Leishinania antibodies in serum samples from dogs with visceral leishmamosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In

  15. Detecting Malaria Hotspots: A Comparison of Rapid Diagnostic Test, Microscopy, and Polymerase Chain Reaction.

    Science.gov (United States)

    Mogeni, Polycarp; Williams, Thomas N; Omedo, Irene; Kimani, Domtila; Ngoi, Joyce M; Mwacharo, Jedida; Morter, Richard; Nyundo, Christopher; Wambua, Juliana; Nyangweso, George; Kapulu, Melissa; Fegan, Gregory; Bejon, Philip

    2017-11-27

    Malaria control strategies need to respond to geographical hotspots of transmission. Detection of hotspots depends on the sensitivity of the diagnostic tool used. We conducted cross-sectional surveys in 3 sites within Kilifi County, Kenya, that had variable transmission intensities. Rapid diagnostic test (RDT), microscopy, and polymerase chain reaction (PCR) were used to detect asymptomatic parasitemia, and hotspots were detected using the spatial scan statistic. Eight thousand five hundred eighty-one study participants were surveyed in 3 sites. There were statistically significant malaria hotspots by RDT, microscopy, and PCR for all sites except by microscopy in 1 low transmission site. Pooled data analysis of hotspots by PCR overlapped with hotspots by microscopy at a moderate setting but not at 2 lower transmission settings. However, variations in degree of overlap were noted when data were analyzed by year. Hotspots by RDT were predictive of PCR/microscopy at the moderate setting, but not at the 2 low transmission settings. We observed long-term stability of hotspots by PCR and microscopy but not RDT. Malaria control programs may consider PCR testing to guide asymptomatic malaria hotspot detection once the prevalence of infection falls. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  16. Aircraft control surface failure detection and isolation using the OSGLR test. [orthogonal series generalized likelihood ratio

    Science.gov (United States)

    Bonnice, W. F.; Motyka, P.; Wagner, E.; Hall, S. R.

    1986-01-01

    The performance of the orthogonal series generalized likelihood ratio (OSGLR) test in detecting and isolating commercial aircraft control surface and actuator failures is evaluated. A modification to incorporate age-weighting which significantly reduces the sensitivity of the algorithm to modeling errors is presented. The steady-state implementation of the algorithm based on a single linear model valid for a cruise flight condition is tested using a nonlinear aircraft simulation. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection and isolation performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling on dynamic pressure and flap deflection is examined. Based on this testing, the OSGLR algorithm should be capable of detecting control surface failures that would affect the safe operation of a commercial aircraft. Isolation may be difficult if there are several surfaces which produce similar effects on the aircraft. Extending the algorithm over the entire operating envelope of a commercial aircraft appears feasible.

  17. Impact of the rapid antigen detection test in diagnosis and treatment of acute pharyngotonsillitis in a pediatric emergency room.

    Science.gov (United States)

    Cardoso, Débora Morais; Gilio, Alfredo Elias; Hsin, Shieh Huei; Machado, Beatriz Marcondes; de Paulis, Milena; Lotufo, João Paulo B; Martinez, Marina Baquerizo; Grisi, Sandra Josefina E

    2013-01-01

    To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.

  18. Early Oscillation Detection for DC/DC Converter Fault Diagnosis

    Science.gov (United States)

    Wang, Bright L.

    2011-01-01

    The electrical power system of a spacecraft plays a very critical role for space mission success. Such a modern power system may contain numerous hybrid DC/DC converters both inside the power system electronics (PSE) units and onboard most of the flight electronics modules. One of the faulty conditions for DC/DC converter that poses serious threats to mission safety is the random occurrence of oscillation related to inherent instability characteristics of the DC/DC converters and design deficiency of the power systems. To ensure the highest reliability of the power system, oscillations in any form shall be promptly detected during part level testing, system integration tests, flight health monitoring, and on-board fault diagnosis. The popular gain/phase margin analysis method is capable of predicting stability levels of DC/DC converters, but it is limited only to verification of designs and to part-level testing on some of the models. This method has to inject noise signals into the control loop circuitry as required, thus, interrupts the DC/DC converter's normal operation and increases risks of degrading and damaging the flight unit. A novel technique to detect oscillations at early stage for flight hybrid DC/DC converters was developed.

  19. A comparison of in vitro tests and a faecal egg count reduction test in detecting anthelmintic resistance in horse strongyles

    DEFF Research Database (Denmark)

    Craven, J.; Bjørn, H.; Barnes, E.H.

    1999-01-01

    This study reports a comparison between faecal egg count reduction test (FECRT), egg hatch assay (EHA) and larval development assay (LDA) for detecting anthelmintic resistance in equine strongyles. Resistance to benzimidazoles was demonstrated in 33 of 42 (79%) farms tested by FECRT and in 32 (62......%) of the 52 farms tested by EHA. As the reference strain used was not fully susceptible to benzimidazoles it was not possible to determine the level of resistance by LDA. Pyrantel resistance was indicated on three of 15 farms by faecal egg count reduction. Resistance was also indicated by LDA for one...

  20. Test of a detection structure for a high-resolution vertex chamber

    International Nuclear Information System (INIS)

    Gruenewald, M.W.

    1988-01-01

    For the LEP experiment L3 a self-supporting detection structure in the TEC principle for the central vertex chamber was tested both with particles and with laser beams. The main topic of this thesis lied thereby on the determination of the coordinate of the particle passage along the signal-wire axis. Two different methods for the determination of this coordinate along the signal wire were studied. (orig./HSI) [de

  1. Can the Bruckner test be used as a rapid screening test to detect significant refractive errors in children?

    Directory of Open Access Journals (Sweden)

    Kothari Mihir

    2007-01-01

    Full Text Available Purpose: To assess the suitability of Brückner test as a screening test to detect significant refractive errors in children. Materials and Methods: A pediatric ophthalmologist prospectively observed the size and location of pupillary crescent on Brückner test as hyperopic, myopic or astigmatic. This was compared with the cycloplegic refraction. Detailed ophthalmic examination was done for all. Sensitivity, specificity, positive predictive value and negative predictive value of Brückner test were determined for the defined cutoff levels of ametropia. Results: Ninety-six subjects were examined. Mean age was 8.6 years (range 1 to 16 years. Brückner test could be completed for all; the time taken to complete this test was 10 seconds per subject. The ophthalmologist identified 131 eyes as ametropic, 61 as emmetropic. The Brückner test had sensitivity 91%, specificity 72.8%, positive predictive value 85.5% and negative predictive value 83.6%. Of 10 false negatives four had compound hypermetropic astigmatism and three had myopia. Conclusions: Brückner test can be used to rapidly screen the children for significant refractive errors. The potential benefits from such use may be maximized if programs use the test with lower crescent measurement cutoffs, a crescent measurement ruler and a distance fixation target.

  2. INTERNAL CONTROLS IN ENSURING GOOD CORPORATE GOVERNANCE IN FINANCIAL INSTITUTIONS

    Directory of Open Access Journals (Sweden)

    KOSMAS NJANIKE

    2011-01-01

    Full Text Available This paper assessed factors that influence the internal controls in ensuring good corporate governance in financial institutions in developing economies with special reference to Zimbabwe. The research paper assessed how lack of internal controls affected good corporate governance and aimed to bring out elements of good corporate governance. It emerged that failure to effectively implement internal controls contributed significantly to poor corporate governance. The study discovered that internal control system overrides and the issue of “fact cat” directors also contributed to poor corporate governance. The study recommended that there is need for the board of directors to guarantee an organizational structure that clearly defines management responsibilities, authority and reporting relationships. There is also need to ensure that delegated responsibilities are effectively carried out to ensure compliance with internal controls of the financial institution concerned.

  3. 14C-urea breath test in the detection of Helicobacter pylori infection

    International Nuclear Information System (INIS)

    Artiko, V.M.; Obradovic, V.B.; Petrovic, N.S.; Davidovic, B.M.; Grujic-Adanja, G.S.; Nastic-Miric, D.R.; Milosavljevic, T.N.

    2001-01-01

    Helicobacter pylori infection is supposed to be one of the major causes of digestive and other diseases. Among a lot of invasive and non-invasive methods for its detection, none is ideal. The aim is an assessment of the Helicobacter pylori infection in the stomach using breath test and comparison to other diagnostic methods, as well as following up the effects of therapy. In 17 patients with digestive discomfort, breath test, rapid urease test and histology were performed, while in 47 patients with proven HP infection the effect of therapy was followed up using breath test and clinical findings. Breath test was performed after per oral administration of the capsule of 14 C urea (37 kBq). Findings of the breath and urease tests were in accordance in 14/17 patients (83%) while breath test and histology in 16/17 patients (94%). During follow-up of the therapeutic effects, breath test and clinical findings were in accordance in 43/47 patients (98%). Breath test can be useful in diagnosis but is a method of choice in following up the patients after therapy for H. pylori infection, because it is non-invasive, fast and precise. (author)

  4. Ensuring Peace and Reconciliation while Holding Leaders ...

    African Journals Online (AJOL)

    need to be adopted to ensure that both organizations fulfil their mandate to address impunity on the ... international law; international relations and political studies. ...... 'not any other consideration', which was an attempt to assuage any fears that she ... system, which should play into the hands of the AU – in theory. Yet this.

  5. Ensuring food security

    Directory of Open Access Journals (Sweden)

    Valeriy Valentinovich Patsiorkovskiy

    2011-12-01

    Full Text Available This paper is devoted to the questions of further development of agricultural and food policy in the Russian Federation. The subject of in-depth consideration is the problem related to ensuring food safety. A critical review and analysis of major regulations in the field of food safety is made, including in the implementation of sanitary and epidemiological surveillance. The necessity of the expansion of measures to improve the statistics of food poisoning is grounded. The basic reasons for the spread of management practices of production and sale of food products that pose a threat to human life are revealed. The factors of unhindered penetration of local markets in the cities and the surrounding countrysides with counterfeiting, smuggling and production of global junk food manufacturers and consumer goods are defined. A systematic view is put on the problems of food production in the private farms, ways to limit direct access to the market of food and food raw materials, which production was not controlled and who have not passed state registration, are suggested. One of these problems is creation of independent industrial structures that link production and sales of small-scale sector goods.

  6. Detecting a Weak Association by Testing its Multiple Perturbations: a Data Mining Approach

    Science.gov (United States)

    Lo, Min-Tzu; Lee, Wen-Chung

    2014-05-01

    Many risk factors/interventions in epidemiologic/biomedical studies are of minuscule effects. To detect such weak associations, one needs a study with a very large sample size (the number of subjects, n). The n of a study can be increased but unfortunately only to an extent. Here, we propose a novel method which hinges on increasing sample size in a different direction-the total number of variables (p). We construct a p-based `multiple perturbation test', and conduct power calculations and computer simulations to show that it can achieve a very high power to detect weak associations when p can be made very large. As a demonstration, we apply the method to analyze a genome-wide association study on age-related macular degeneration and identify two novel genetic variants that are significantly associated with the disease. The p-based method may set a stage for a new paradigm of statistical tests.

  7. A Novel Computerized Test for Detecting and Monitoring Visual Attentional Deficits and Delirium in the ICU.

    Science.gov (United States)

    Green, Cameron; Hendry, Kirsty; Wilson, Elizabeth S; Walsh, Timothy; Allerhand, Mike; MacLullich, Alasdair M J; Tieges, Zoë

    2017-07-01

    Delirium in the ICU is associated with poor outcomes but is under-detected. Here we evaluated performance of a novel, graded test for objectively detecting inattention in delirium, implemented on a custom-built computerized device (Edinburgh Delirium Test Box-ICU). A pilot study was conducted, followed by a prospective case-control study. Royal Infirmary of Edinburgh General ICU. A pilot study was conducted in an opportunistic sample of 20 patients. This was followed by a validation study in 30 selected patients with and without delirium (median age, 63 yr; range, 23-84) who were assessed with the Edinburgh Delirium Test Box-ICU on up to 5 separate days. Presence of delirium was assessed using the Confusion Assessment Method for the ICU. The Edinburgh Delirium Test Box-ICU involves a behavioral assessment and a computerized test of attention, requiring patients to count slowly presented lights. Thirty patients were assessed a total of 79 times (n = 31, 23, 15, 8, and 2 for subsequent assessments; 38% delirious). Edinburgh Delirium Test Box-ICU scores (range, 0-11) were lower for patients with delirium than those without at the first (median, 0 vs 9.5), second (median, 3.5 vs 9), and third (median, 0 vs 10.5) assessments (all p Delirium Test Box-ICU score less than or equal to 5 was 100% sensitive and 92% specific to delirium across assessments. Longitudinally, participants' Edinburgh Delirium Test Box-ICU performance was associated with delirium status. These findings suggest that the Edinburgh Delirium Test Box-ICU has diagnostic utility in detecting ICU delirium in patients with Richmond Agitation and Sedation Scale Score greater than -3. The Edinburgh Delirium Test Box-ICU has potential additional value in longitudinally tracking attentional deficits because it provides a range of scores and is sensitive to change.

  8. Simultaneous quantitative detection of multiple tumor markers with a rapid and sensitive multicolor quantum dots based immunochromatographic test strip.

    Science.gov (United States)

    Wang, Chunying; Hou, Fei; Ma, Yicai

    2015-06-15

    A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 μL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Antigen spot test (AST): a highly sensitive assay for the detection of antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Herbrink, P; van Bussel, F J; Warnaar, S O [Rijksuniversiteit Leiden (Netherlands)

    1982-02-12

    A method is described for detection of antibodies by means of nitrocellulose or diazobenzyloxymethyl (DBM) paper on which various antigens have been spotted. The sensitivity of this antigen spot test (AST) is comparable with that of RIA and ELISA. The method requires only nanogram amounts of antigen. Since a variety of antigens can be spotted on a single piece of nitrocellulose or DBM paper, this antigen spot test is especially useful for specificity controls on antibodies.

  10. Prospective audit of a one-centre combined nuchal translucency and triple test programme for the detection of trisomy 21.

    Science.gov (United States)

    Babbur, Vijayalakshmi; Lees, Christoph C; Goodburn, Sandra F; Morris, Nigel; Breeze, Andrew C G; Hackett, Gerald A

    2005-06-01

    To determine detection and false-positive rates for trisomy 21 using two-stage combined nuchal translucency (NT) and triple testing, whilst disclosing abnormal nuchal measurements at the scan. A prospective audit in a UK women's hospital, of 3188 women with singleton pregnancies, requesting screening for trisomy 21. Median age was 37 years (range 19-46). Women were offered NT screening at 11 to 14 weeks. Those with NT > or =3 mm were offered chorionic villus sampling. Those declining CVS, and those with NT risk of trisomy 21 > or = 1:250, based on age, NT, and triple test results were offered amniocentesis. Using a 3-mm NT 'cut-off' identified 16/25 cases of trisomy 21 (64%; 95% CI 38.8, 78.9). Of 2725 women who had a combined nuchal plus triple test assessment, 79 (2.6%) had a > or = 1:250 term risk of trisomy 21. Forty (1.3%) had amniocentesis identifying 6/9 remaining cases (67%:95% CI:27.9, 92.5). Overall, the detection rate was 88% (95% CI:68.8, 97.5) for a 4.8% FPR. For the screened population, to achieve an 88% detection rate using the triple test alone, the predicted FPR would be 20%. Conversely, for an FPR of 4.8% using the triple test alone, the detection rate would be only 60%. In a high-risk group, the combination of NT with triple test offers detection of trisomy 21 at least equivalent to either test, while allowing disclosure of an abnormal NT at the scan and reducing the FPR. Importantly, the FPR is less than 5%, considerably lower than expected for triple test alone for this population.

  11. Memory detection 2.0: The first web-based memory detection test

    NARCIS (Netherlands)

    Kleinberg, B.; Verschuere, B.

    2015-01-01

    There is accumulating evidence that reaction times (RTs) can be used to detect recognition of critical (e.g., crime) information. A limitation of this research base is its reliance upon small samples (average n = 24), and indications of publication bias. To advance RT-based memory detection, we

  12. Note on Studying Change Point of LRD Traffic Based on Li's Detection of DDoS Flood Attacking

    Directory of Open Access Journals (Sweden)

    Zhengmin Xia

    2010-01-01

    Full Text Available Distributed denial-of-service (DDoS flood attacks remain great threats to the Internet. To ensure network usability and reliability, accurate detection of these attacks is critical. Based on Li's work on DDoS flood attack detection, we propose a DDoS detection method by monitoring the Hurst variation of long-range dependant traffic. Specifically, we use an autoregressive system to estimate the Hurst parameter of normal traffic. If the actual Hurst parameter varies significantly from the estimation, we assume that DDoS attack happens. Meanwhile, we propose two methods to determine the change point of Hurst parameter that indicates the occurrence of DDoS attacks. The detection rate associated with one method and false alarm rate for the other method are also derived. The test results on DARPA intrusion detection evaluation data show that the proposed approaches can achieve better detection performance than some well-known self-similarity-based detection methods.

  13. Evaluation of three commercial rapid tests for detecting antibodies to human immunodeficiency virus.

    Science.gov (United States)

    Ng, K P; Saw, T L; Baki, A; Kamarudin, R

    2003-08-01

    Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest are simple/rapid tests for the detection of antibodies to HIV-1 and HIV-2 in human whole blood, serum and plasma samples. The assay is one step and the result is read visually within 15 minutes. Using 92 known HIV-1 reactive sera and 108 known HIV-1 negative sera, the 3 HIV tests correctly identified all the known HIV-1 reactive and negative samples. The results indicated that Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest HIV are as sensitive and specific (100% concordance) as Microparticle Enzyme Immunoassay. The data indicated that these 3 HIV tests are effective testing systems for diagnosis of HIV infection in a situation when the conventional Enzyme Immunoassay is not suitable.

  14. Destructive examination of test plates 1 and 2 of the defects detection trials

    International Nuclear Information System (INIS)

    Crutzen, S.; Buergers, W.; Violin, F.; Di Piazza, L.; Cowburn, K.; Sargent, T.

    1983-01-01

    A further phase of the UKAEA defect detection trials (described previously) with PWR pressure vessel steels is reported. The evaluation of NDT exercise results must be based on destructive examination of the plates used during the exercise. Tests are described and results given. (U.K.)

  15. How reliable are the sup 14 C-urea breath test and specific serology for the detection of gastric campylobacter

    Energy Technology Data Exchange (ETDEWEB)

    Husebye, E; O' Leary, D; Skar, V; Melby, K [Ullevaal Sykehus, Oslo (Norway)

    1990-01-01

    Detection of gastric campylobacter by the {sup 14}C-urea breath test and serology were correlated to biopsy culture in 25 unselected outpatients referred for gastroscopy. All the 17 culture-positive patients had positive {sup 14}C-urea breath test, and 16 had positive serology. Of eight culture-negative patients, six patients had negative breath test and seven negative serology. A high degree of reproducibility was found when two subsequent breath tests were performed in 11 healthy volunteers. The breath test values obtained at 10 min showed a strong correlation to the accumulated values within 30 min. Breath sampling once, 10 min after intake of 2.5 {mu}Ci {sup 14}C-urea, seems sufficient for the detection of gastric campylobacter. The {sup 14}C-urea breath test correlates well with biopsy culture and provides a sensitive tool for the detection of gastric campylobacter. Serology also corresponds well with biopsy culture and should provide a useful tool for epidemiologic studies. 22 refs., 4 figs., 1 tab.

  16. Analysis of CFRP Joints by Means of T-Pull Mechanical Test and Ultrasonic Defects Detection

    Directory of Open Access Journals (Sweden)

    Caterina Casavola

    2018-04-01

    Full Text Available Defects detection within a composite component, with the aim of understanding and predicting its mechanical behavior, is of great importance in the aeronautical field because the irregularities of the composite material could compromise functionality. The aim of this paper is to detect defects by means of non-destructive testing (NDT on T-pull samples made by carbon fiber reinforced polymers (CFRP and to evaluate their effect on the mechanical response of the material. Samples, obtained from an industrial stringer having an inclined web and realized with a polymeric filler between cap and web, were subjected to ultrasonic monitoring and then to T-pull mechanical tests. All samples were tested with the same load mode and the same test configuration. An experimental set-up consisting of a semiautomatic C-scan ultrasonic mapping system with a phased array probe was designed and developed, optimizing control parameters and implementing image processing software. The present work is carried out on real composites parts that are characterized by having their intrinsic defectiveness, as opposed to the previous similar results in the literature mainly obtained on composite parts with artificially produced defects. In fact, although samples under study were realized free from defects, ultrasonic mapping found defectiveness inside the material. Moreover, the ultrasonic inspection could be useful in detecting both the location and size of defects. Experimental data were critically analyzed and qualitatively correlated with results of T-pull mechanical tests in order to better understand and explain mechanical behavior in terms of fracture mode.

  17. Analysis of CFRP Joints by Means of T-Pull Mechanical Test and Ultrasonic Defects Detection.

    Science.gov (United States)

    Casavola, Caterina; Palano, Fania; De Cillis, Francesco; Tati, Angelo; Terzi, Roberto; Luprano, Vincenza

    2018-04-18

    Defects detection within a composite component, with the aim of understanding and predicting its mechanical behavior, is of great importance in the aeronautical field because the irregularities of the composite material could compromise functionality. The aim of this paper is to detect defects by means of non-destructive testing (NDT) on T-pull samples made by carbon fiber reinforced polymers (CFRP) and to evaluate their effect on the mechanical response of the material. Samples, obtained from an industrial stringer having an inclined web and realized with a polymeric filler between cap and web, were subjected to ultrasonic monitoring and then to T-pull mechanical tests. All samples were tested with the same load mode and the same test configuration. An experimental set-up consisting of a semiautomatic C-scan ultrasonic mapping system with a phased array probe was designed and developed, optimizing control parameters and implementing image processing software. The present work is carried out on real composites parts that are characterized by having their intrinsic defectiveness, as opposed to the previous similar results in the literature mainly obtained on composite parts with artificially produced defects. In fact, although samples under study were realized free from defects, ultrasonic mapping found defectiveness inside the material. Moreover, the ultrasonic inspection could be useful in detecting both the location and size of defects. Experimental data were critically analyzed and qualitatively correlated with results of T-pull mechanical tests in order to better understand and explain mechanical behavior in terms of fracture mode.

  18. [Membrane-filtration immunoassay: reagents, methods and the diagnostic and technical means for detection].

    Science.gov (United States)

    Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A

    1999-01-01

    The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.

  19. Accuracy of non-invasive 13C-urea breath test compared to invasive tests for helicobacter pylori detection

    International Nuclear Information System (INIS)

    Bilal, R.; Khaar, B.; Omar, M.; Qureshi, T.Z.; Ahmed, T.; Latif, Z.; Jaffery, I.; Omar, M.

    2007-01-01

    To compare the sensitivity, specificity and Positive Predictive Value (PPV) of histology, Campylobacter-Like Organism (CLO) test, culture and 13C-Urea Breath Test (UBT) for the diagnosis of Helicobacter pylori infection. District Headquarter Hospital, Rawalpindi, Military Hospital, Rawalpindi and Pakistan Institute of Science and Technology (PINSTECH), Nilore, Islamabad from June 2002 to 2003. Three mucosal biopsy specimens were obtained during endoscopy of 90 symptomatic patients. Histology, CLO test and culture were performed on these specimens. Breath samples for 13C-UBT were collected and sent to RIAD, PINSTECH on the same day for isotope ratio mass spectrometry. For analysis purpose, each of the tests was fixed as the gold standard in turn and the others were then compared against it. In addition, any two as well as any three positive tests were then set as the gold standard and the other tests compared against them to calculate the sensitivity, specificity, accuracy and PPV of other tests. Urea breath test had the highest sensitivity, ranging from 95 to 100%, against all the gold standards with specificity ranging from 55 to 100%, whereas the sensitivity of histological examination was around 98% but it had comparatively lower specificity (49-89%). The CLO test had a sensitivity range of 86-100% and specificity of 67-100%. Culture had the minimum sensitivity (59-70%) but had highest specificity (96-100%) against all the gold standards. Age and gender had no effect on p-value of each test or in combination. The urea breath test has shown the highest ability to detect the organism with 95-100% sensitivity in symptomatic individuals and specificity, which is comparable to other tests. (author)

  20. Nuclear Power Plant Thermocouple Sensor-Fault Detection and Classification Using Deep Learning and Generalized Likelihood Ratio Test

    Science.gov (United States)

    Mandal, Shyamapada; Santhi, B.; Sridhar, S.; Vinolia, K.; Swaminathan, P.

    2017-06-01

    In this paper, an online fault detection and classification method is proposed for thermocouples used in nuclear power plants. In the proposed method, the fault data are detected by the classification method, which classifies the fault data from the normal data. Deep belief network (DBN), a technique for deep learning, is applied to classify the fault data. The DBN has a multilayer feature extraction scheme, which is highly sensitive to a small variation of data. Since the classification method is unable to detect the faulty sensor; therefore, a technique is proposed to identify the faulty sensor from the fault data. Finally, the composite statistical hypothesis test, namely generalized likelihood ratio test, is applied to compute the fault pattern of the faulty sensor signal based on the magnitude of the fault. The performance of the proposed method is validated by field data obtained from thermocouple sensors of the fast breeder test reactor.

  1. Ensuring Academic Standards in US Higher Education

    Science.gov (United States)

    Dill, David D.

    2014-01-01

    The most recent research on college-student learning in the US by respected scholars such as Richard Arum, Josipa Roksa, and Ernest Pascarella suggests that the nation's means of ensuring academic standards in US colleges and universities are not working effectively. Like US K-12 education and health care, the US higher education system is…

  2. Correlation of phenotypic tests with the presence of the blaZ gene for detection of beta-lactamase.

    Science.gov (United States)

    Ferreira, Adriano Martison; Martins, Katheryne Benini; Silva, Vanessa Rocha da; Mondelli, Alessandro Lia; Cunha, Maria de Lourdes Ribeiro de Souza da

    Staphylococcus aureus and Staphylococcus saprophyticus are the most common and most important staphylococcal species associated with urinary tract infections. The objective of the present study was to compare and to evaluate the accuracy of four phenotypic methods for the detection of beta-lactamase production in Staphylococcus spp. Seventy-three strains produced a halo with a diameter ≤28mm (penicillin resistant) and all of them were positive for the blaZ gene. Among the 28 susceptible strain (halo ≥29mm), 23 carried the blaZ gene and five did not. The zone edge test was the most sensitive (90.3%), followed by MIC determination (85.5%), but the specificity of the former was low (40.0%). The nitrocefin test was the least sensitive (28.9%). However, the nitrocefin test together with the disk diffusion method showed the highest specificity (100%). The present results demonstrated that the zone edge test was the most sensitive phenotypic test for detection of beta-lactamase, although it is still not an ideal test to detect this type of resistance since its specificity was low. However, the inhibition halo diameter of the penicillin disk can be used together with the zone edge test since the same disk is employed in the two tests. Combined analysis of the two tests shows a sensitivity of 90.3% and specificity of 100%, proving better sensitivity, especially for S. saprophyticus. This is a low-cost test of easy application and interpretation that can be used in small and medium-sized laboratories where susceptibility testing is usually performed by the disk diffusion method. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  3. Correlation of phenotypic tests with the presence of the blaZ gene for detection of beta-lactamase

    Directory of Open Access Journals (Sweden)

    Adriano Martison Ferreira

    Full Text Available Abstract Staphylococcus aureus and Staphylococcus saprophyticus are the most common and most important staphylococcal species associated with urinary tract infections. The objective of the present study was to compare and to evaluate the accuracy of four phenotypic methods for the detection of beta-lactamase production in Staphylococcus spp. Seventy-three strains produced a halo with a diameter ≤28 mm (penicillin resistant and all of them were positive for the blaZ gene. Among the 28 susceptible strain (halo ≥29 mm, 23 carried the blaZ gene and five did not. The zone edge test was the most sensitive (90.3%, followed by MIC determination (85.5%, but the specificity of the former was low (40.0%. The nitrocefin test was the least sensitive (28.9%. However, the nitrocefin test together with the disk diffusion method showed the highest specificity (100%. The present results demonstrated that the zone edge test was the most sensitive phenotypic test for detection of beta-lactamase, although it is still not an ideal test to detect this type of resistance since its specificity was low. However, the inhibition halo diameter of the penicillin disk can be used together with the zone edge test since the same disk is employed in the two tests. Combined analysis of the two tests shows a sensitivity of 90.3% and specificity of 100%, proving better sensitivity, especially for S. saprophyticus. This is a low-cost test of easy application and interpretation that can be used in small and medium-sized laboratories where susceptibility testing is usually performed by the disk diffusion method.

  4. Development of a one-step immunochromatographic strip test for the detection of sennosides A and B.

    Science.gov (United States)

    Putalun, Waraporn; Morinaga, Osamu; Tanaka, Hiroyuki; Shoyama, Yukihiro

    2004-01-01

    An immunochromatographic strip test was developed to detect sennoside A (1) and sennoside B (2) using anti-1 and anti-2 monoclonal antibodies. The qualitative assay was based on a competitive immunoassay in which the detector reagent consisted of colloidal gold particles coated with the respective sennoside antibodies. The capture reagents were 1- and 2-human serum albumin (HSA) conjugates immobilised on a nitrocellulose membrane on the test strip. The sample containing 1 and 2, together with detector reagent, passed over the zone where the capture reagents had been immobilised. The analytes in the sample competed for binding to the limited amount of antibodies in the detector reagent with the immobilised 1- and 2-HSA conjugates on the membrane and hence positive samples showed no colour in the capture spot zone. Detection limits for the strip test were 125 ng/mL for both sennosides. The assay system is useful as a rapid and simple screening method for the detection of 1 and 2 in plants, drugs and body fluids.

  5. ENSURING THE SAFETY OF ROAD TRANSPORTATION OF GOODS

    Directory of Open Access Journals (Sweden)

    Liudmila Nikolaevna Andronikova

    2017-05-01

    Full Text Available The article investigates Russian and foreign regulatory documents, governing the issues of cargo securing in road transport, and sets out recommendations to ensure the safety of road transportation of goods by means of their attachment.

  6. 14C-urea breath test as a method to detect Campylobacter pylori colonization

    NARCIS (Netherlands)

    Rauws, E. A.; van Royen, E. A.; Tytgat, G. N.

    1989-01-01

    Campylobacter pylori may cause type B gastritis. C. pylori produces urease, and the presence of this enzyme in gastric mucosal biopsies is a marker for colonization with the microorganism. The value of a breath test to detect C. pylori colonization in non-ulcer dyspepsia patients was investigated.

  7. Urine and bladder washing cytology for detection of urothelial carcinoma: standard test with new possibilities

    International Nuclear Information System (INIS)

    Flezar, Margareta Strojan

    2010-01-01

    Light microscopic evaluation of cell morphology in preparations from urine or bladder washing containing exfoliated cells is a standard and primary method for the detection of bladder cancer and also malignancy from other parts of the urinary tract. The cytopathologic examination is a valuable method to detect an early recurrence of malignancy or new primary carcinoma during the follow-up of patients after the treatment of bladder cancer. Characteristic cellular and nuclear signs of malignancy indicate invasive or in situ urothelial carcinoma or high-grade papillary urothelial carcinoma. However, low sensitivity of the method reflects the unreliable cytopathologic diagnosis of low-grade urothelial neoplasms as cellular and nuclear signs of malignancy in these neoplasms are poorly manifested. Many different markers were developed to improve the diagnosis of bladder carcinoma on urinary samples. UroVysion™ test is among the newest and most promising tests. By the method of in situ hybridization one can detect specific cytogenetic changes of urothelial carcinoma

  8. A multipronged approach to ensuring food security | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2011-02-01

    Feb 1, 2011 ... ... nations committed themselves to ensuring an enabling environment and ... to eradicate poverty and guarantee access to sufficient, safe food to all. They also agreed to promote a fair world trade system, and to work to ...

  9. Detection of surface deformation and ionospheric perturbation by the North Korea nuclear test

    Science.gov (United States)

    Park, S. C.; Lee, W. J.; Sohn, D. H.; Lee, D. K.; Jung, H. S.

    2017-12-01

    We used remote sensing data to detect the changes on surface and ionosphere due to the North Korea nuclear test. To analyze the surface deformation before and after the 6th North Korea (NK) nuclear test, we used Satellite Aperture Radar (SAR) images. It was reported that there were some surface deformation with about 10 cm by the 4th test (Wei, 2017) and the 5th test (Jo, 2017) using Interferometric SAR (InSAR) technique. However we could not obtain surface deformation by the 6th test using InSAR with Advanced Land Observation Satellite 2 (ALOS-2) data because of low coherence in the area close to the epicenter. Although the low coherence can be occurred due to several reasons, the main reason may be large deformation in this particular case. Therefore we applied pixel offset method to measure the amount of surface deformation in the area with low coherence. Pixel offset method calculates the deformation in the directions along track and Line-of-Sight (LOS) using cross correlation of intensity of two SAR images before and after the event for a pixel and is used frequently to obtain large deformation of glacier (e.g. Lee et al., 2015). Applying pixel offset method to the area of the 6th NK nuclear test, we obtained about 3 m surface deformation in maximum. It seems that the larger deformation occurs as the mountain slope is steeper.We then analyzed ionospheric perturbation using Global Navigation Satellite System (GNSS) data. If acoustic wave by a nuclear test goes up to the ionosphere and disturbs electron density, then the changes in slant total electron content (STEC) may be detected by GNSS satellites. STEC perturbation has been reported in the previous NK nuclear tests (e.g. Park et al., 2011). We analyzed the third order derivatives of STEC for 51 GNSS stations in South Korea and found that some perturbation were appeared at 4 stations about 20 40 minutes after the test.

  10. Familiarization, validity and smallest detectable difference of the isometric squat test in evaluating maximal strength.

    Science.gov (United States)

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2018-02-06

    Isometric multi-joint tests are considered reliable and have strong relationships with 1RM performance. However, limited evidence is available for the isometric squat in terms of effects of familiarization and reliability. This study aimed to assess, the effect of familiarization, stability reliability, determine the smallest detectible difference, and the correlation of the isometric squat test with 1RM squat performance. Thirty-six strength-trained participants volunteered to take part in this study. Following three familiarization sessions, test-retest reliability was evaluated with a 48-hour window between each time point. Isometric squat peak, net and relative force were assessed. Results showed three familiarizations were required, isometric squat had a high level of stability reliability and smallest detectible difference of 11% for peak and relative force. Isometric strength at a knee angle of ninety degrees had a strong significant relationship with 1RM squat performance. In conclusion, the isometric squat is a valid test to assess multi-joint strength and can discriminate between strong and weak 1RM squat performance. Changes greater than 11% in peak and relative isometric squat performance should be considered as meaningful in participants who are familiar with the test.

  11. Development and testing of incident detection algorithms. Vol. 2, research methodology and detailed results.

    Science.gov (United States)

    1976-04-01

    The development and testing of incident detection algorithms was based on Los Angeles and Minneapolis freeway surveillance data. Algorithms considered were based on times series and pattern recognition techniques. Attention was given to the effects o...

  12. Development of a multiplex lateral flow strip test for foot-and-mouth disease virus detection using monoclonal antibodies.

    Science.gov (United States)

    Yang, Ming; Caterer, Nigel R; Xu, Wanhong; Goolia, Melissa

    2015-09-01

    Foot-and-mouth disease (FMD) is one of the world's most highly contagious animal diseases with tremendous economic consequences. A rapid and specific test for FMD diagnosis at the site of a suspected outbreak is crucial for the implementation of control measures. This project developed a multiplex lateral flow immunochromatographic strip test (multiplex-LFI) for the rapid detection and serotyping of FMD viruses. The monoclonal antibodies (mAbs) against serotypes O, A, and Asia 1 were used as capture mAbs. The mAbs were conjugated with fluorescein, rhodamine or biotin for serotype O, A and Asia 1, respectively. The detection mAbs which consisted of a serotype-independent mAb in combination with one serotype A-specific mAb and one Asia 1-specific mAb, were each colloidal gold-conjugated. The strips used in this study contained one control line and three test lines, which corresponded to one of the three serotypes, O, A or Asia 1. The newly developed multiplex-LFI strip test specifically identified serotype O (n=46), A (n=45) and Asia 1 (n=17) in all tested field isolates. The sensitivity of this strip test was comparable to the double antibody sandwich ELISA for serotypes O and A, but lower than the ELISA for serotype Asia 1. The multiplex-LFI strip test identified all tissue suspensions from animals that were experimentally inoculated with serotypes O, A or Asia 1. FMD viruses were detected in 38% and 50% of the swab samples from the lesion areas of experimentally inoculated sheep for serotypes O and A, respectively. The capability of the multiplex-LFI strip tests to produce rapid results with high specificity for FMD viruses of multiple serotypes makes this test a valuable tool to detect FMD viruses at outbreak sites. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  13. E-learning platform for automated testing of electronic circuits using signature analysis method

    Science.gov (United States)

    Gherghina, Cǎtǎlina; Bacivarov, Angelica; Bacivarov, Ioan C.; Petricǎ, Gabriel

    2016-12-01

    Dependability of electronic circuits can be ensured only through testing of circuit modules. This is done by generating test vectors and their application to the circuit. Testability should be viewed as a concerted effort to ensure maximum efficiency throughout the product life cycle, from conception and design stage, through production to repairs during products operating. In this paper, is presented the platform developed by authors for training for testability in electronics, in general and in using signature analysis method, in particular. The platform allows highlighting the two approaches in the field namely analog and digital signature of circuits. As a part of this e-learning platform, it has been developed a database for signatures of different electronic components meant to put into the spotlight different techniques implying fault detection, and from this there were also self-repairing techniques of the systems with this kind of components. An approach for realizing self-testing circuits based on MATLAB environment and using signature analysis method is proposed. This paper analyses the benefits of signature analysis method and simulates signature analyzer performance based on the use of pseudo-random sequences, too.

  14. Early detection of Haemonchus contortus infection in sheep using three different faecal occult blood tests

    Directory of Open Access Journals (Sweden)

    A.V. Rodríguez

    2015-07-01

    Full Text Available Haemonchus contortus is a blood-sucking parasite causing the presence of faecal occult blood (FOB. The objective was to study three different FOB tests in order to have a new indicator of H. contortus infection in sheep that could be included in the genetic evaluation system as an alternative selection criterion to faecal worm egg count (FEC. A total of 29 Corriedale lambs were experimentally infected with 10.000 larvae of H. contortus. Stool samples were recorded for FEC and FOB tests (Hexagon, Hematest® and Multistix®, blood for packed cell volume (PCV, haemoglobin, white and red blood cell count (RBC, and FAMACHA© for scoring anaemia. At the end of the experiment lambs were slaughtered to worm burden count. Field infection was achieved in 309 Merino lambs under natural parasite challenge. FEC data were normalized through logarithmic transformation (LnFEC. Pearson correlation was estimated to examine the relationship between all traits. The three tests were able to detect the presence of FOB at day 11. FEC, PCV and RBC decreased to sub-normal values from day 18. FAMACHA© score 3 was considered to be indicative of anaemia. Most of the correlations were of high magnitude, with the exception of Multistix® test that was moderately correlated with haematological parameters, LnFEC and FEC. In field infection, most samples were negative to FOB tests and the correlations were lower than those calculated under experimental infection. In conclusion, FOB tests were able to detect haemonchosis earlier than FEC under high experimental parasite challenge. However, they were not able to detect FOB under natural mixed parasite challenge. FAMACHA© and PCV demonstrated to be good indicators of Haemonchosis, having moderate to high correlations with FEC.

  15. Acceptance test procedure, 241-SY-101 Flexible Receiver System, Phase III testing

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1994-01-01

    This Acceptance Test Procedure is for the 241-SY-101 Flexible Receiver System, Phase III Testing. This procedure will test the sealing integrity of the Flexible Receiver System to ensure that release of waste and aerosols will be minimized during the removal of the test mixer pump from tank SY-101

  16. A network based covariance test for detecting multivariate eQTL in saccharomyces cerevisiae.

    Science.gov (United States)

    Yuan, Huili; Li, Zhenye; Tang, Nelson L S; Deng, Minghua

    2016-01-11

    Expression quantitative trait locus (eQTL) analysis has been widely used to understand how genetic variations affect gene expressions in the biological systems. Traditional eQTL is investigated in a pair-wise manner in which one SNP affects the expression of one gene. In this way, some associated markers found in GWAS have been related to disease mechanism by eQTL study. However, in real life, biological process is usually performed by a group of genes. Although some methods have been proposed to identify a group of SNPs that affect the mean of gene expressions in the network, the change of co-expression pattern has not been considered. So we propose a process and algorithm to identify the marker which affects the co-expression pattern of a pathway. Considering two genes may have different correlations under different isoforms which is hard to detect by the linear test, we also consider the nonlinear test. When we applied our method to yeast eQTL dataset profiled under both the glucose and ethanol conditions, we identified a total of 166 modules, with each module consisting of a group of genes and one eQTL where the eQTL regulate the co-expression patterns of the group of genes. We found that many of these modules have biological significance. We propose a network based covariance test to identify the SNP which affects the structure of a pathway. We also consider the nonlinear test as considering two genes may have different correlations under different isoforms which is hard to detect by linear test.

  17. Laboratory Tests of Multiplex Detection of PCR Amplicons Using the Luminex 100 Flow Analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Venkateswaran, K.S.; Nasarabadi, S.; Langlois, R.G.

    2000-05-05

    Lawrence Livermore National Laboratory (LLNL) demonstrated the power of flow cytometry in detecting the biological agents simulants at JFT III. LLNL pioneered in the development of advanced nucleic acid analyzer (ANM) for portable real time identification. Recent advances in flow cytometry provide a means for multiplexed nucleic acid detection and immunoassay of pathogenic microorganisms. We are presently developing multiplexed immunoassays for the simultaneous detection of different simulants. Our goal is to build an integrated instrument for both nucleic acid analysis and immuno detection. In this study we evaluated the Luminex LX 100 for concurrent identification of more than one PCR amplified product. ANAA has real-time Taqman fluorescent detection capability for rapid identification of field samples. However, its multiplexing ability is limited by the combination of available fluorescent labels. Hence integration of ANAA with flow cytometry can give the rapidity of ANAA amplification and the multiplex capability of flow cytometry. Multiplexed flow cytometric analysis is made possible using a set of fluorescent latex microsphere that are individually identified by their red and infrared fluorescence. A green fluorochrome is used as the assay signal. Methods were developed for the identification of specific nucleic acid sequences from Bacillus globigii (Bg), Bacillus thuringensis (Bt) and Erwinia herbicola (Eh). Detection sensitivity using different reporter fluorochromes was tested with the LX 100, and also different assay formats were evaluated for their suitability for rapid testing. A blind laboratory trial was carried out December 22-27, 1999 to evaluate bead assays for multiplex identification of Bg and Bt PCR products. This report summarizes the assay development, fluorochrome comparisons, and the results of the blind trial conducted at LLNL for the laboratory evaluation of the LX 100 flow analyzer.

  18. USA Hire Testing Platform

    Data.gov (United States)

    Office of Personnel Management — The USA Hire Testing Platform delivers tests used in hiring for positions in the Federal Government. To safeguard the integrity of the hiring processes and ensure...

  19. A Test for Cluster Bias: Detecting Violations of Measurement Invariance across Clusters in Multilevel Data

    Science.gov (United States)

    Jak, Suzanne; Oort, Frans J.; Dolan, Conor V.

    2013-01-01

    We present a test for cluster bias, which can be used to detect violations of measurement invariance across clusters in 2-level data. We show how measurement invariance assumptions across clusters imply measurement invariance across levels in a 2-level factor model. Cluster bias is investigated by testing whether the within-level factor loadings…

  20. System principles, mathematical models and methods to ensure high reliability of safety systems

    Science.gov (United States)

    Zaslavskyi, V.

    2017-04-01

    Modern safety and security systems are composed of a large number of various components designed for detection, localization, tracking, collecting, and processing of information from the systems of monitoring, telemetry, control, etc. They are required to be highly reliable in a view to correctly perform data aggregation, processing and analysis for subsequent decision making support. On design and construction phases of the manufacturing of such systems a various types of components (elements, devices, and subsystems) are considered and used to ensure high reliability of signals detection, noise isolation, and erroneous commands reduction. When generating design solutions for highly reliable systems a number of restrictions and conditions such as types of components and various constrains on resources should be considered. Various types of components perform identical functions; however, they are implemented using diverse principles, approaches and have distinct technical and economic indicators such as cost or power consumption. The systematic use of different component types increases the probability of tasks performing and eliminates the common cause failure. We consider type-variety principle as an engineering principle of system analysis, mathematical models based on this principle, and algorithms for solving optimization problems of highly reliable safety and security systems design. Mathematical models are formalized in a class of two-level discrete optimization problems of large dimension. The proposed approach, mathematical models, algorithms can be used for problem solving of optimal redundancy on the basis of a variety of methods and control devices for fault and defects detection in technical systems, telecommunication networks, and energy systems.

  1. EU-approved rapid tests for bovine spongiform encephalopathy detect atypical forms: a study for their sensitivities.

    Directory of Open Access Journals (Sweden)

    Daniela Meloni

    Full Text Available Since 2004 it become clear that atypical bovine spongiform encephalopthies (BSEs exist in cattle. Whenever their detection has relied on active surveillance plans implemented in Europe since 2001 by rapid tests, the overall and inter-laboratory performance of these diagnostic systems in the detection of the atypical strains has not been studied thoroughly to date. To fill this gap, the present study reports on the analytical sensitivity of the EU-approved rapid tests for atypical L- and H-type and classical BSE in parallel. Each test was challenged with two dilution series, one created from a positive pool of the three BSE forms according to the EURL standard method of homogenate preparation (50% w/v and the other as per the test kit manufacturer's instructions. Multilevel logistic models and simple logistic models with the rapid test as the only covariate were fitted for each BSE form analyzed as directed by the test manufacturer's dilution protocol. The same schemes, but excluding the BSE type, were then applied to compare test performance under the manufacturer's versus the water protocol. The IDEXX HerdChek ® BSE-scrapie short protocol test showed the highest sensitivity for all BSE forms. The IDEXX® HerdChek BSE-scrapie ultra short protocol, the Prionics®--Check WESTERN and the AJ Roboscreen® BetaPrion tests showed similar sensitivities, followed by the Roche® PrionScreen, the Bio-Rad® TeSeE™ SAP and the Prionics®--Check PrioSTRIP in descending order of analytical sensitivity. Despite these differences, the limit of detection of all seven rapid tests against the different classes of material set within a 2 log(10 range of the best-performing test, thus meeting the European Food Safety Authority requirement for BSE surveillance purposes. These findings indicate that not many atypical cases would have been missed surveillance since 2001 which is important for further epidemiological interpretations of the sporadic character of

  2. On the infrasound detected from the 2013 and 2016 DPRK's underground nuclear tests

    NARCIS (Netherlands)

    Assink, J. D.; Averbuch, G.; Smets, P.S.M.; Evers, L.G.

    2016-01-01

    The underground nuclear tests by the Democratic People's Republic of Korea (DPRK) generated atmospheric infrasound both in 2013 and 2016. Clear detections were made in the Russian Federation (I45RU) and Japan (I30JP) in 2013 at stations from the International Monitoring System. Both tropospheric

  3. Non-invasive prenatal testing: a review of international implementation and challenges

    Directory of Open Access Journals (Sweden)

    Allyse M

    2015-01-01

    Full Text Available Megan Allyse,1 Mollie A Minear,2 Elisa Berson,3 Shilpa Sridhar,3 Margaret Rote,3 Anthony Hung,3 Subhashini Chandrasekharan4 1Institute for Health and Aging, University of California San Francisco, San Francisco, California, USA, 2Duke Science & Society, Duke University, Durham, NC, USA, 3Trinity College of Arts and Sciences, Duke University, Durham, NC, USA; 4Duke Global Health Institute, Duke University, Durham, NC, USA Abstract: Noninvasive prenatal genetic testing (NIPT is an advance in the detection of fetal chromosomal aneuploidies that analyzes cell-free fetal DNA in the blood of a pregnant woman. Since its introduction to clinical practice in Hong Kong in 2011, NIPT has quickly spread across the globe. While many professional societies currently recommend that NIPT be used as a screening method, not a diagnostic test, its high sensitivity (true positive rate and specificity (true negative rate make it an attractive alternative to the serum screens and invasive tests currently in use. Professional societies also recommend that NIPT be accompanied by genetic counseling so that families can make informed reproductive choices. If NIPT becomes more widely adopted, States will have to implement regulation and oversight to ensure it fits into existing legal frameworks, with particular attention to returning fetal sex information in areas where sex-based abortions are prevalent. Although there are additional challenges for NIPT uptake in the developing world, including the lack of health care professionals and infrastructure, the use of NIPT in low-resource settings could potentially reduce the need for skilled clinicians who perform invasive testing. Future advances in NIPT technology promise to expand the range of conditions that can be detected, including single gene disorders. With these advances come questions of how to handle incidental findings and variants of unknown significance. Moving forward, it is essential that all stakeholders have

  4. Rapid and quantitative detection of C-reactive protein using quantum dots and immunochromatographic test strips

    Directory of Open Access Journals (Sweden)

    Cheng X

    2014-12-01

    Full Text Available Xianglin Cheng,1,* Xu Pu,2,* Pen Jun,3 XiaoBo Zhu,3 Di Zhu,4 Ming Chen1 1Department of Laboratory Medicine, First Affiliated Hospital of Yangtze University, Jingzhou, 2Department of Laboratory Medicine, RenMin Hospital of Wuhan University, Wuhan, 3Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei, People’s Republic of China; 4Department of Medical Oncology, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA *These authors contributed equally to this study and share first authorship Background: Rapid immunochromatographic tests can detect disease markers in 10–15 minutes, which facilitates clinical diagnosis and treatment programs. However, most immunochromatographic tests employ gold nanoparticles as reporters, and these have only moderate sensitivity and act as qualitative methods for analyzing high biomarker concentrations. Methods: In this study, we introduce quantum dots (QDs as fluorescent probes and immunochromatographic strips to develop quantitative fluorescence point-of-care tests (QF-POCT to analyze C-reactive protein (CRP levels. Goat anti-rabbit IgG and rabbit IgG were used as control antibodies, and mouse monoclonal CRP antibody pairs were used for disease marker detection. One monoclonal CRP antibody was conjugated with QDs and served as a signal antibody, and the other monoclonal CRP antibody was dispensed onto the nitrocellulose membrane and served as a capturing antibody. In the presence of CRP, the fluorescence intensity of the monoclonal antibody-CRP-monoclonal antibody sandwich complex captured on the nitrocellulose membrane was determined using the fluorescence strip reader. Results: QF-POCT assays could quantitatively analyze the concentration of CRP in 15 minutes had a detection limit of 0.25 mg/L, and had a wide detection linearity range (0.5–300 mg/L. The intra-assay and interassay

  5. Evaluation of a rapid immunodiagnostic test kit for detection of African lyssaviruses from brain material

    Directory of Open Access Journals (Sweden)

    W. Markotter

    2009-09-01

    Full Text Available Rapid immunodiagnostic test kit was evaluated against a selection of isolates of lyssavirus genotypes occurring in Africa. The test was carried out in parallel comparison with the fluorescent antibody test (FAT and isolates representing previously established phylogenetic groups from each genotype were included. The specificity of the rapid immunodiagnostic test compared favourably with the FAT and was found to detect all representatives of genotypes 1, 2, 3 and 4 in brain samples of either field cases or suckling mouse brain inoculates.

  6. National Ignition Facility TestController for automated and manual testing

    Energy Technology Data Exchange (ETDEWEB)

    Zielinski, Jason, E-mail: fishler2@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2012-12-15

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  7. National Ignition Facility TestController for automated and manual testing

    International Nuclear Information System (INIS)

    Zielinski, Jason

    2012-01-01

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  8. Combined use of the modified Hodge test and carbapenemase inhibition test for detection of carbapenemase-producing Enterobacteriaceae and metallo-β-lactamase-producing Pseudomonas spp.

    Science.gov (United States)

    Song, Wonkeun; Hong, Seong Geun; Yong, Dongeun; Jeong, Seok Hoon; Kim, Hyun Soo; Kim, Han-Sung; Kim, Jae-Seok; Bae, Il Kwon

    2015-03-01

    We evaluated the combined use of the modified Hodge test (MHT) and carbapenemase inhibition test (CIT) using phenylboronic acid (PBA) and EDTA to detect carbapenemase-producing Enterobacteriaceae (CPE) and metallo-β-lactamase (MBL)-producing Pseudomonas spp. A total of 49 isolates of CPE (15 Klebsiella pneumoniae carbapenemase [KPC], 5 Guiana extended-spectrum β-lactamase [GES]-5, 9 New Delhi metallo-β-lactamase [NDM]-1, 5 Verona integron-encoded metallo-β-lactamase [VIM]-2, 3 imipenem-hydrolyzing β-lactamase [IMP], and 12 oxacillinase [OXA]-48-like), 25 isolates of MBL-producing Pseudomonas spp. (14 VIM-2 and 11 IMP), and 35 carbapenemase-negative controls were included. The MHT was performed for all isolates as recommended by the Clinical and Laboratory Standards Institute. Enhanced growth of the indicator strain was measured in mm with a ruler. The CIT was performed by directly dripping PBA and EDTA solutions onto carbapenem disks that were placed on Mueller-Hinton agar plates seeded with the test strain. Considering the results of the MHT with the ertapenem disk in Enterobacteriaceae and Pseudomonas spp., the CIT with the meropenem disk in Enterobacteriaceae, and the imipenem disk in Pseudomonas spp., three combined disk tests, namely MHT-positive plus PBA-positive, EDTA-positive, and MHT-positive plus PBA-negative plus EDTA-negative, had excellent sensitivity and specificity for the detection of KPC- (100% sensitivity and 100% specificity), MBL- (94% sensitivity and 100% specificity), and OXA-48-like-producing isolates (100% sensitivity and 100% specificity), respectively. Combined use of the MHT and CIT with PBA and EDTA, for the detection of CPE and MBL-producing Pseudomonas spp., is effective in detecting and characterizing carbapenemases in routine laboratories.

  9. An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhexiang; Wang, Jun; Wang, Hua; Li, Yao Q.; Lin, Yuehe

    2012-05-30

    A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population

  10. A quench detection/logging system for the SSCL Magnet Test Laboratory

    International Nuclear Information System (INIS)

    Kim, K.; Coles, M.; Dryer, J.; Lambert, D.

    1993-05-01

    The quench in a magnet describes a process which occurs while the superconductivity state goes to the normal resistive state. The consequence of a quench is the conversion of the stored electromagnetic energy into heat. During this process the initiating point will reach a high temperature, which will char the insulation or melt the conductor and thereby destroy the magnet. To prevent the magnet from being lost, it is standard practice to observe several resistance and/or inductance voltages across the magnet as quench signatures -- detection. When a quench symptom is detected, protection operations are initiated: proper shutdown of the magnet excitation systems and treatment to dilute the heat energy at a spot -- protection. The temperature rise is diluted by firing heaters along the length of the magnet to insure that the dissipated energy is spread. To develop a reliable quench detection system, two distinct approaches have been tried in the past: (i) Understanding of the Noise Mechanism and Sub-system Optimization, and (ii) Escaping from the Known Electromagnetic Noises by Observing Optical Waves or Acoustic Waves. The MTL of SSCL confronts a mass-measurement of about 10,000 production magnets. To meet the testing schedule, the false quench detection rate needs to be further optimized while the true quench detection rate remains secure for the magnet measurement safety. To meet these requirements, we followed an iterative top-down approach. First we defined the signal and noise characteristics of the quench phenomena by using existing software tools to build a rapid prototype system incorporating all proven functionality of the existing system. Then we further optimize the system through iterative upgrading based on our signal and noise character findings

  11. Comparison between the Counter Immunoelectrophoresis Test and Mouse Neutralization Test for the Detection of Antibodies against Rabies Virus in Dog Sera

    Directory of Open Access Journals (Sweden)

    Luzia Helena Queiroz da Silva

    2002-03-01

    Full Text Available The detection of rabies antibodies is extremely valuable for epidemiological studies, determination of immune status in man, animals, and for the diagnosis of the disease. Several serological procedures have been described for this purpose. The present study reports a comparison between counterimmunoelectrophoresis test (CIET and mouse neutralization test (MNT in the detection of antibodies against rabies virus from 212 serum samples of vaccinated dogs. The agreement between both techniques was 79.7% and a significative association was demonstrated. The correlation coefficients between MNT and the CIET titers was determined considering 88 samples showing positive results in both techniques [CIET = 2 and MNT = 5 (0.13 IU/ml] and resulted r² = 0.7926 (p < 0.001. The performance of CIET system was technically simple, cheap and rapid, and thereby it could be useful for serological monitoring of dog vaccination campaigns as well as for individual analysis.

  12. Deterrence by risk of detection? An inquiry into how elite athletes perceive the deterrent effect of the doping testing regime in their sport

    DEFF Research Database (Denmark)

    Overbye, Marie Birch

    2017-01-01

    Aims: A central paradigm of global anti-doping policy is detection-based deterrence, i.e. the risk of testing and exclusion from sport are effective doping deterrents. This paper investigates how elite athletes perceive the deterrent effect of the testing strategy in their sport and explores...... the likelihood of testing nor detection as deterrents. 8% did not consider the likelihood of testing and detection nor the ban from sport as deterrents.  Conclusions: Testing programmes–as a strategy to detect and deter doping–are no great deterrent for many athletes. The results highlight the limitations...... whether and how specific factors such as the frequency of testing influence athletes’ perceptions of testing as a deterrent.  Methods: 645 Danish elite athletes completed a web-based questionnaire about their perceptions of testing efforts in their sport.  Findings: 75% of the athletes considered...

  13. Strategies for ensuring quality data from Indian investigational sites

    Directory of Open Access Journals (Sweden)

    Antal K Hajos

    2011-01-01

    Full Text Available The topic of ensuring quality and compliance is and must be a top priority in the conduct of clinical trials, as warranted by regulatory guidelines as well as the inherent responsibility of the professionals conducting such research. Fast-growing emerging clinical geographies such as India demand special attention due to rapid growth and associated factors that may put study quality at risk. In this paper, we used the basic principle of PDCA (Plan, Do, Check, and Adjust to structure the processes of a clinical trial from protocol to final analysis in order to highlight the interactive nature of involved people and processes required to ensure quality of data and site functioning.

  14. Damage Detection and Deteriorating Structural Systems

    DEFF Research Database (Denmark)

    Long, Lijia; Thöns, Sebastian; Döhler, Michael

    2017-01-01

    This paper addresses the quantification of the value of damage detection system and algorithm information on the basis of Value of Information (VoI) analysis to enhance the benefit of damage detection information by providing the basis for its optimization before it is performed and implemented....... The approach of the quantification the value of damage detection information builds upon the Bayesian decision theory facilitating the utilization of damage detection performance models, which describe the information and its precision on structural system level, facilitating actions to ensure the structural...... detection information is determined utilizing Bayesian updating. The damage detection performance is described with the probability of indication for different component and system damage states taking into account type 1 and type 2 errors. The value of damage detection information is then calculated...

  15. Highly selective and reversible chemosensor for Pd(2+) detected by fluorescence, colorimetry, and test paper.

    Science.gov (United States)

    Wang, Mian; Liu, Xiaomei; Lu, Huizhe; Wang, Hongmei; Qin, Zhaohai

    2015-01-21

    A "turn-on" fluorescent and colorimetric chemosensor (RBS) for Pd(2+) has been designed and synthesized through introduction of sulfur as a ligand atom to Rhodamine B. RBS exhibits high selectivity (freedom from the interference of Hg(2+ )in particular) and sensitivity toward Pd(2+) with a detection limit as low as 2.4 nM. RBS is also a reversible sensor, and it can be made into test paper to detect Pd(2+) in pure water. Compared to the chemosensors that introduced phosphorus to Rhodamine to detect Pd(2+), RBS can be synthesized more simply and economically.

  16. Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test

    DEFF Research Database (Denmark)

    Bregnbak, David; Johansen, Jeanne D.; Jellesen, Morten Stendahl

    2015-01-01

    Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit...... exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release...

  17. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    Science.gov (United States)

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  18. A New Acoustic Emission Sensor Based Gear Fault Detection Approach

    Directory of Open Access Journals (Sweden)

    Junda Zhu

    2013-01-01

    Full Text Available In order to reduce wind energy costs, prognostics and health management (PHM of wind turbine is needed to ensure the reliability and availability of wind turbines. A gearbox is an important component of a wind turbine. Therefore, developing effective gearbox fault detection tools is important to the PHM of wind turbine. In this paper, a new acoustic emission (AE sensor based gear fault detection approach is presented. This approach combines a heterodyne based frequency reduction technique with time synchronous average (TSA and spectrum kurtosis (SK to process AE sensor signals and extract features as condition indictors for gear fault detection. Heterodyne technique commonly used in communication is first employed to preprocess the AE signals before sampling. By heterodyning, the AE signal frequency is down shifted from several hundred kHz to below 50 kHz. This reduced AE signal sampling rate is comparable to that of vibration signals. The presented approach is validated using seeded gear tooth crack fault tests on a notational split torque gearbox. The approach presented in this paper is physics based and the validation results have showed that it could effectively detect the gear faults.

  19. Immunochromatographic Strip Test for Rapid Detection of Diphtheria Toxin: Description and Multicenter Evaluation in Areas of Low and High Prevalence of Diphtheria

    Science.gov (United States)

    Engler, K. H.; Efstratiou, A.; Norn, D.; Kozlov, R. S.; Selga, I.; Glushkevich, T. G.; Tam, M.; Melnikov, V. G.; Mazurova, I. K.; Kim, V. E.; Tseneva, G. Y.; Titov, L. P.; George, R. C.

    2002-01-01

    An immunochromatographic strip (ICS) test was developed for the detection of diphtheria toxin by using an equine polyclonal antibody as the capture antibody and colloidal gold-labeled monoclonal antibodies specific for fragment A of the diphtheria toxin molecule as the detection antibody. The ICS test has been fully optimized for the detection of toxin from bacterial cultures; the limit of detection was approximately 0.5 ng of diphtheria toxin per ml within 10 min. In a comparative study with 915 pure clinical isolates of Corynebacterium spp., the results of the ICS test were in complete agreement with those of the conventional Elek test. The ICS test was also evaluated for its ability to detect toxigenicity from clinical specimens (throat swabs) in two field studies conducted within areas of the former USSR where diphtheria is epidemic. Eight hundred fifty throat swabs were examined by conventional culture and by use of directly inoculated broth cultures for the ICS test. The results showed 99% concordance (848 of 850 specimens), and the sensitivity and specificity of the ICS test were 98% (95% confidence interval, 91 to 99%) and 99% (95% confidence interval, 99 to 100%), respectively. PMID:11773096

  20. Detection of anti neutrophil antibodies by radio-iodinated protein A binding test

    International Nuclear Information System (INIS)

    Cartron, J.; Muller, J.Y.; Tchernia, G.; Paule, B.; Varet, B.

    1983-01-01

    The granulocyte associated IgG in normal and neutropenic subjects has been determined by a direct quantitative assay using radiolabeled staphylococcal protein A. This assay allows to postulate an immunological mechanism to explain the neutropenia in 19 cases of neutropenias associated with malfunctions of the immune system and in 4 cases of idiopathic neutropenias. Discussed in this report is the possible interaction of immune complexes bound in vivo to the granulocytes. By an immunofluorescence test, it has been possible to detect IgG or IgM antibodies in only 52% of patients with a positive direct assay. The determination of granulocyte-associated IgG is therefore a better indicator for defining an auto-immune neutropenia than the detection of free antibodies in the sera [fr

  1. Modern Paradigm of Ensuring Competitive Advantages of an Enterprise

    Directory of Open Access Journals (Sweden)

    Klymchuk Alyona O.

    2014-01-01

    Full Text Available The article considers evolution of development of the paradigm of ensuring competitive advantages of an enterprise. Foreign and domestic scientists focus on individual directions of development of competitive advantages and pay insufficient attention to new management concepts – development of the information society, knowledge economy and dynamism of integration processes. The goal of the study is formation of the modern paradigm of ensuring competitive advantages of an enterprise with consideration of tendencies of development of the knowledge economy, information society and integration processes. Enterprise competitiveness is a synergetic characteristic, which reflects enterprise capability of dynamic response to changes of the market situation with the aim of keeping predominance over other economic subjects. Management of the future, on the basis of the management 2.0 concept, should take into account interests not only of top management and shareholders but also employees, local communities and territories and meet requirements of the society in general, individual groups of consumers and tendencies of development of managerial and information technologies. The paradigm of the modern theory of ensuring competitive advantages should include models of keeping competitive advantages in the existing markets and models of development of future markets; strategy of development of enterprise competitiveness, human capital development and efficient enterprise management.

  2. Validation of the shake test for detecting freeze damage to adsorbed vaccines.

    Science.gov (United States)

    Kartoglu, Umit; Ozgüler, Nejat Kenan; Wolfson, Lara J; Kurzatkowski, Wiesław

    2010-08-01

    To determine the validity of the shake test for detecting freeze damage in aluminium-based, adsorbed, freeze-sensitive vaccines. A double-blind crossover design was used to compare the performance of the shake test conducted by trained health-care workers (HCWs) with that of phase contrast microscopy as a "gold standard". A total of 475 vials of 8 different types of World Health Organization prequalified freeze-sensitive vaccines from 10 different manufacturers were used. Vaccines were kept at 5 degrees C. Selected numbers of vials from each type were then exposed to -25 degrees C and -2 degrees C for 24-hour periods. There was complete concordance between HCWs and phase-contrast microscopy in identifying freeze-damaged vials and non-frozen samples. Non-frozen samples showed a fine-grain structure under phase contrast microscopy, but freeze-damaged samples showed large conglomerates of massed precipitates with amorphous, crystalline, solid and needle-like structures. Particles in the non-frozen samples measured from 1 microm (vaccines against diphtheria-tetanus-pertussis; Haemophilus influenzae type b; hepatitis B; diphtheria-tetanus-pertussis-hepatitis B) to 20 microm (diphtheria and tetanus vaccines, alone or in combination). By contrast, aggregates in the freeze-damaged samples measured up to 700 microm (diphtheria-tetanus-pertussis) and 350 microm on average. The shake test had 100% sensitivity, 100% specificity and 100% positive predictive value in this study, which confirms its validity for detecting freeze damage to aluminium-based freeze-sensitive vaccines.

  3. Detection of Two-Level Inverter Open-Circuit Fault Using a Combined DWT-NN Approach

    Directory of Open Access Journals (Sweden)

    Bilal Djamel Eddine Cherif

    2018-01-01

    Full Text Available Three-phase static converters with voltage structure are widely used in many industrial systems. In order to prevent the propagation of the fault to other components of the system and ensure continuity of service in the event of a failure of the converter, efficient and rapid methods of detection and localization must be implemented. This paper work addresses a diagnostic technique based on the discrete wavelet transform (DWT algorithm and the approach of neural network (NN, for the detection of an inverter IGBT open-circuit switch fault. To illustrate the merits of the technique and validate the results, experimental tests are conducted using a built voltage inverter fed induction motor. The inverter is controlled by the SVM control strategy.

  4. UserTesting.com: A Tool for Usability Testing of Online Resources

    Science.gov (United States)

    Koundinya, Vikram; Klink, Jenna; Widhalm, Melissa

    2017-01-01

    Extension educators are increasingly using online resources in their program design and delivery. Usability testing is essential for ensuring that these resources are relevant and useful to learners. On the basis of our experiences with iteratively developing products using a testing service called UserTesting, we promote the use of fee-based…

  5. Change Detection for Remote Monitoring of Underground Nuclear Testing: Comparison with Seismic and Associated Explosion Source Phenomenological Data

    DEFF Research Database (Denmark)

    Canty, M.; Jahnke, G.; Nielsen, Allan Aasbjerg

    2005-01-01

    The analysis of open-source satellite imagery is in process of establishing itself as an important tool for monitoring nuclear activities throughout the world which are relevant to disarmament treaties, like e. g. the Comprehensive Nuclear-Test-Ban Treaty (CTBT). However, the detection of anthrop......The analysis of open-source satellite imagery is in process of establishing itself as an important tool for monitoring nuclear activities throughout the world which are relevant to disarmament treaties, like e. g. the Comprehensive Nuclear-Test-Ban Treaty (CTBT). However, the detection...... of conventional multispectral satellite platforms with moderate ground resolution (Landsat TM, ASTER) to detect changes over wide areas.We chose the Nevada Test Site (NTS), USA, for a case study because of the large amount of available ground truth information. The analysis is based on the multivariate alteration...

  6. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    Science.gov (United States)

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  7. Structural health monitoring and probability of detection estimation

    Science.gov (United States)

    Forsyth, David S.

    2016-02-01

    Structural health monitoring (SHM) methods are often based on nondestructive testing (NDT) sensors and are often proposed as replacements for NDT to lower cost and/or improve reliability. In order to take advantage of SHM for life cycle management, it is necessary to determine the Probability of Detection (POD) of the SHM system just as for traditional NDT to ensure that the required level of safety is maintained. Many different possibilities exist for SHM systems, but one of the attractive features of SHM versus NDT is the ability to take measurements very simply after the SHM system is installed. Using a simple statistical model of POD, some authors have proposed that very high rates of SHM system data sampling can result in high effective POD even in situations where an individual test has low POD. In this paper, we discuss the theoretical basis for determining the effect of repeated inspections, and examine data from SHM experiments against this framework to show how the effective POD from multiple tests can be estimated.

  8. Development of the innovative food industry in the conditions of ensuring food security

    OpenAIRE

    Berdiev S.

    2017-01-01

    The purpose of this article is to ensure the safety of food and through the development of innovative food industry and learning to increase the production of food. Work to ensure food security of the Republic of Uzbekistan has its own characteristics and analysis of trends and problems identified in this area. As well as ensuring the safety of food and food industry offer based on the priority directions of scientific and practical recommendations developed.

  9. [THE COMPARATIVE ANALYSIS OF RESULTS OF DETECTION OF CARCINOGENIC TYPES OF HUMAN PAPILLOMA VIRUS BY QUALITATIVE AND QUANTITATIVE TESTS].

    Science.gov (United States)

    Kuzmenko, E T; Labigina, A V; Leshenko, O Ya; Rusanov, D N; Kuzmenko, V V; Fedko, L P; Pak, I P

    2015-05-01

    The analysis of results of screening (n = 3208; sexually active citizen aged from 18 to 59 years) was carried out to detect oncogene types of human papilloma virus in using qualitative (1150 females and 720 males) and quantitative (polymerase chain reaction in real-time (843 females and 115 males) techniques. The human papilloma virus of high oncogene type was detected in 65% and 68.4% of females and in 48.6% and 53% of males correspondingly. Among 12 types of human papilloma virus the most frequently diagnosed was human papilloma virus 16 independently of gender of examined and technique of analysis. In females, under application of qualitative tests rate of human papilloma virus 16 made up to 18.3% (n = 280) and under application of quantitative tests Rte of human papilloma virus made up to 14.9% (n = 126; p ≤ 0.05). Under examination of males using qualitative tests rate of human papilloma virus 16 made up to 8.3% (n = 60) and under application of qualitative tests made up to 12.2% (n = 14; p ≥ 0.05). Under application of qualitative tests rate of detection on the rest ofoncogene types of human papilloma virus varied in females from 3.4% to 8.4% and in males from 1.8% to 5.9%. Under application of qualitative tests to females rate of human papilloma virus with high viral load made up to 68.4%, with medium viral load - 2.85% (n = 24) and with low viral load -0.24% (n = 2). Under application of quantitative tests in males rate of detection of types of human papilloma virus made up to 53% and at that in all high viral load was established. In females, the most of oncogene types of human papilloma virus (except for 31, 39, 59) are detected significantly more often than in males.

  10. Visualization of and Software for Omnibus Test Based Change Detected in a Time Series of Polarimetric SAR Data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Conradsen, Knut; Skriver, Henning

    2017-01-01

    Based on an omnibus likelihood ratio test statistic for the equality of several variance-covariance matrices following the complex Wishart distribution and a factorization of this test statistic with associated p-values, change analysis in a time series of multilook polarimetric SAR data...... in the covariance matrix representation is carried out. The omnibus test statistic and its factorization detect if and when change occurs. Using airborne EMISAR and spaceborne RADARSAT-2 data this paper focuses on change detection based on the p-values, on visualization of change at pixel as well as segment level......, and on computer software....

  11. Early detection of fatigue cracks by means of nondestructive testing, NDT; Tidig detektering av utmattningssprickor genom ofoerstoerande provning, OFP

    Energy Technology Data Exchange (ETDEWEB)

    Broddegaard, Mattias [Siemens Industrial Turbines, Finspaang (Sweden)

    2004-12-01

    Components in gas turbines, steam turbines and boilers are subjected to both high and low cycle fatigue. The lifetime of components is established by calculations based on conservative assumptions and safety factors, which means that most components will have a real life far exceeding the calculated. Conventional nondestructive testing is aimed at detecting macroscopic defects, such as cracks, inclusions and other discontinuities in the material. By having the possibility of detecting damage at a microscopic level, the risk of fractures in components subjected to fatigue can be reduced and the interval between testing occasions can be extended. The project goal has been to establish knowledge about possibilities and limitations for early detection of low and high cycle fatigue damage, by a literature survey and by practical experiments on low cycle fatigue specimens in 12% Cr-steel, for the following nondestructive testing methods: MWM (Meandering Winding Magnetometer) eddy current testing; and Nonlinear ultrasonics, both classical (second harmonic) and non-classical (crack closure). The project started with a literature survey. This resulted in a proposal for specimen design and selection of testing techniques and project partners. Manufacturing of specimens in 12% Cr-steel, designation X22CrMoV12-1, and low cycle fatigue testing at 300 deg C testing temperature was carried out at Siemens Industrial Turbines in Finspaang. Specimens with 0, 25, 50, 75 and 100% consumed life, based on the number of cycles to presence of macroscopic cracks, were produced. MWM eddy current testing was carried out by Jentek Sensors Inc. in the USA. Measurements with nonlinear ultrasonics were carried out by Siemens Corporate Technology in Munich and at Blekinge Univ. The specimens were finally examined in SEM and light optical microscope in Finspaang. In the literature, results showing that early detection of fatigue damage by nondestructive testing is possible, can be found. By

  12. Pressurized water reactor monitoring. Study of detection, diagnostic and estimation methods (least error squares and filtering)

    International Nuclear Information System (INIS)

    Gillet, M.

    1986-07-01

    This thesis presents a study for the surveillance of the ''primary coolant circuit inventory monitoring'' of a pressurized water reactor. A reference model is developed in view of an automatic system ensuring detection and diagnostic in real time. The methods used for the present application are statistical tests and a method related to pattern recognition. The estimation of failures detected, difficult owing to the non-linearity of the problem, is treated by the least error squares method of the predictor or corrector type, and by filtering. It is in this frame that a new optimized method with superlinear convergence is developed, and that a segmented linearization of the model is introduced, in view of a multiple filtering [fr

  13. Communication equipment radiation resistance ensurance

    International Nuclear Information System (INIS)

    Myrova, L.O.; Chelizhenko, A.Z.

    1983-01-01

    A review of works on radiation resistance of electronic equipment (epsilon epsilon) for 15 years is presented. The effect of ionizing radiation appearing as a result of nuclear explosions in nuclear facilities and in outerspace on epsilon epsilon has been considered. Types of radiation effects in epsilon epsilon, radiation effect on semiconductor devices and integrated circUits, types of epsilon epsilon failures, as well as the procass of radiation-resistant epsilon epsilon designing and selection of its main parameters have been described. The methods of epsilon epsilon flowsheet optimization, application of mathematical simulation and peculiarities of ensurance of epsilon epsilon radiation resistance of communication systems are considered. Peculiarities of designing of radiation-resistant quartz generators, secondary power supply sources and amplifiers are discussed

  14. The Role of Communication in Ensuring Sustained Behavior Change

    Science.gov (United States)

    Webinar series on communications strategies and methods addresses how communications tools can be used throughout the implementation of climate and clean energy programs to achieve behavior change and ensure sustained.

  15. USE OF-EPR-DL FIELD TEST EQUIPMENT FOR DETECTION OF SIGMA PHASE

    Directory of Open Access Journals (Sweden)

    Abraão Danilo Gomes Barreto

    2014-06-01

    Full Text Available This work has objective to correlate the intergranular corrosion susceptibility test named EPR-DL (Electrochemical Potentiokinetic Reactivation of Double Loop with the sigma phase formation and other phases. It has been used samples from a UNS S32760 steel pipe for conducting various aging heat treatments. Held isothermal heat treatment at 850°C for 1 min, 10 min, 30 min, 1 h, 1h30min and 10 h. Each heat treated sample and as received were tested using the electrochemical polarization reactivation of double loop technique (EPR-DL. It was possible the detection of deleterious phases with DL-EPR portable cell. The EPR-DL test of some samples showed a second peak of reactivation in which the results showed that this peak might be associated with ferrite or be related to the presence of chi phase

  16. Reflexion on linear regression trip production modelling method for ensuring good model quality

    Science.gov (United States)

    Suprayitno, Hitapriya; Ratnasari, Vita

    2017-11-01

    Transport Modelling is important. For certain cases, the conventional model still has to be used, in which having a good trip production model is capital. A good model can only be obtained from a good sample. Two of the basic principles of a good sampling is having a sample capable to represent the population characteristics and capable to produce an acceptable error at a certain confidence level. It seems that this principle is not yet quite understood and used in trip production modeling. Therefore, investigating the Trip Production Modelling practice in Indonesia and try to formulate a better modeling method for ensuring the Model Quality is necessary. This research result is presented as follows. Statistics knows a method to calculate span of prediction value at a certain confidence level for linear regression, which is called Confidence Interval of Predicted Value. The common modeling practice uses R2 as the principal quality measure, the sampling practice varies and not always conform to the sampling principles. An experiment indicates that small sample is already capable to give excellent R2 value and sample composition can significantly change the model. Hence, good R2 value, in fact, does not always mean good model quality. These lead to three basic ideas for ensuring good model quality, i.e. reformulating quality measure, calculation procedure, and sampling method. A quality measure is defined as having a good R2 value and a good Confidence Interval of Predicted Value. Calculation procedure must incorporate statistical calculation method and appropriate statistical tests needed. A good sampling method must incorporate random well distributed stratified sampling with a certain minimum number of samples. These three ideas need to be more developed and tested.

  17. Nuclear safeguards: power tool for ensuring nuclear safety and security

    International Nuclear Information System (INIS)

    Ramakumar, K.L.

    2016-01-01

    The quantitative measurement of fissile nuclear materials through independent measurements is one of the cornerstones of the Nuclear Material Accounting and Control (NUMAC) edifice. The verification of the accountancy also represents one of the key elements of international nuclear materials Safeguards. The very basis of NUMAC is to ensure safeguarding nuclear material and to state with confidence, “no significant amount of nuclear material has been withdrawn from its intended civilian use.” Thus, materials accounting systems are designed to account for or keep track of the amounts and locations of sensitive nuclear materials by periodic measurements. The purpose of this activity is to detect missing items (gross defects). A variety of C/S techniques are used, primarily optical surveillance and sealing. These measures serve to back up nuclear material accountancy by providing means by which access to nuclear material can be monitored. Unattended monitoring is a special mode of application of NDA or C/S techniques, or a combination of these, that operates for extended periods of time. The complexity and diversity of facilities containing safeguarded nuclear material require a correspondingly diverse set of verification techniques and equipment. The equipment and techniques used in safeguards are briefly described in this talk

  18. Testing the applicability of rapid on-site enzymatic activity detection for surface water monitoring

    Science.gov (United States)

    Stadler, Philipp; Vogl, Wolfgang; Juri, Koschelnik; Markus, Epp; Maximilian, Lackner; Markus, Oismüller; Monika, Kumpan; Peter, Strauss; Regina, Sommer; Gabriela, Ryzinska-Paier; Farnleitner Andreas, H.; Matthias, Zessner

    2015-04-01

    On-site detection of enzymatic activities has been suggested as a rapid surrogate for microbiological pollution monitoring of water resources (e.g. using glucuronidases, galactosidases, esterases). Due to the possible short measuring intervals enzymatic methods have high potential as near-real time water quality monitoring tools. This presentation describes results from a long termed field test. For twelve months, two ColiMinder devices (Vienna Water Monitoring, Austria) for on-site determination of enzymatic activity were tested for stream water monitoring at the experimental catchment HOAL (Hydrological Open Air Laboratory, Center for Water Resource Systems, Vienna University of Technology). The devices were overall able to follow and reflect the diverse hydrological and microbiological conditions of the monitored stream during the test period. Continuous data in high temporal resolution captured the course of enzymatic activity in stream water during diverse rainfall events. The method also proofed sensitive enough to determine diurnal fluctuations of enzymatic activity in stream water during dry periods. The method was able to capture a seasonal trend of enzymatic activity in stream water that matches the results gained from Colilert18 analysis for E. coli and coliform bacteria of monthly grab samples. Furthermore the comparison of ColiMinder data with measurements gained at the same test site with devices using the same method but having different construction design (BACTcontrol, microLAN) showed consistent measuring results. Comparative analysis showed significant differences between measured enzymatic activity (modified fishman units and pmol/min/100ml) and cultivation based analyses (most probable number, colony forming unit). Methods of enzymatic activity measures are capable to detect ideally the enzymatic activity caused by all active target bacteria members, including VBNC (viable but nonculturable) while cultivation based methods cannot detect VBNC

  19. Testing Digital Electronic Protection Systems

    CERN Document Server

    Gabourin, S

    2011-01-01

    This paper outlines the core concepts and realisation of the Safe Machine Parameters Controller (SMPC) testbench, based on a VME crate and LabVIEW program. Its main goal is to ensure the correct function of the SMPC for the protection of the CERN accelerator complex. To achieve this, the tester has been built to replicate the machine environment and operation, in order to ensure that the chassis under test is completely exercised. The complexity of the task increases with the number of input combinations. This paper also outlines the benefits and weaknesses of developing a test suite independently of the hardware being tested, using the “V” approach.

  20. Omnibus test for change detection in a time sequence of polarimetric SAR data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Conradsen, Knut; Skriver, Henning

    2016-01-01

    in the covariance matrix representation is carried out. The omnibus test statistic and its factorization detect if and when change(s) occur. The technique is demonstrated on airborne EMISAR C-band data but may be applied to ALOS, COSMO-SkyMed, RadarSat-2, Sentinel-1, TerraSAR-X, and Yoagan or other dual- and quad...

  1. Detection of Answer Copying Based on the Structure of a High-Stakes Test

    Science.gov (United States)

    Belov, Dmitry I.

    2011-01-01

    This article presents the Variable Match Index (VM-Index), a new statistic for detecting answer copying. The power of the VM-Index relies on two-dimensional conditioning as well as the structure of the test. The asymptotic distribution of the VM-Index is analyzed by reduction to Poisson trials. A computational study comparing the VM-Index with the…

  2. Exploring the scope of community-based rehabilitation in ensuring ...

    African Journals Online (AJOL)

    ... the scope of community-based rehabilitation in ensuring the holistic ... Rehabilitation is defined as the process of combined ... psychological measures for enabling individuals to at- ... inclusion, meeting basic needs and facilitating access to.

  3. Poisson Approximation-Based Score Test for Detecting Association of Rare Variants.

    Science.gov (United States)

    Fang, Hongyan; Zhang, Hong; Yang, Yaning

    2016-07-01

    Genome-wide association study (GWAS) has achieved great success in identifying genetic variants, but the nature of GWAS has determined its inherent limitations. Under the common disease rare variants (CDRV) hypothesis, the traditional association analysis methods commonly used in GWAS for common variants do not have enough power for detecting rare variants with a limited sample size. As a solution to this problem, pooling rare variants by their functions provides an efficient way for identifying susceptible genes. Rare variant typically have low frequencies of minor alleles, and the distribution of the total number of minor alleles of the rare variants can be approximated by a Poisson distribution. Based on this fact, we propose a new test method, the Poisson Approximation-based Score Test (PAST), for association analysis of rare variants. Two testing methods, namely, ePAST and mPAST, are proposed based on different strategies of pooling rare variants. Simulation results and application to the CRESCENDO cohort data show that our methods are more powerful than the existing methods. © 2016 John Wiley & Sons Ltd/University College London.

  4. Measurement issues associated with quantitative molecular biology analysis of complex food matrices for the detection of food fraud.

    Science.gov (United States)

    Burns, Malcolm; Wiseman, Gordon; Knight, Angus; Bramley, Peter; Foster, Lucy; Rollinson, Sophie; Damant, Andrew; Primrose, Sandy

    2016-01-07

    Following a report on a significant amount of horse DNA being detected in a beef burger product on sale to the public at a UK supermarket in early 2013, the Elliott report was published in 2014 and contained a list of recommendations for helping ensure food integrity. One of the recommendations included improving laboratory testing capacity and capability to ensure a harmonised approach for testing for food authenticity. Molecular biologists have developed exquisitely sensitive methods based on the polymerase chain reaction (PCR) or mass spectrometry for detecting the presence of particular nucleic acid or peptide/protein sequences. These methods have been shown to be specific and sensitive in terms of lower limits of applicability, but they are largely qualitative in nature. Historically, the conversion of these qualitative techniques into reliable quantitative methods has been beset with problems even when used on relatively simple sample matrices. When the methods are applied to complex sample matrices, as found in many foods, the problems are magnified resulting in a high measurement uncertainty associated with the result which may mean that the assay is not fit for purpose. However, recent advances in the technology and the understanding of molecular biology approaches have further given rise to the re-assessment of these methods for their quantitative potential. This review focuses on important issues for consideration when validating a molecular biology assay and the various factors that can impact on the measurement uncertainty of a result associated with molecular biology approaches used in detection of food fraud, with a particular focus on quantitative PCR-based and proteomics assays.

  5. Active Thermography for the Detection of Defects in Powder Metallurgy Compacts

    International Nuclear Information System (INIS)

    Benzerrouk, Souheil; Ludwig, Reinhold; Apelian, Diran

    2007-01-01

    Active thermography is an established NDE technique that has become the method of choice in many industrial applications which require non-contact access to the parts under test. Unfortunately, when conducting on-line infrared (IR) inspection of powder metallic compacts, complications can arise due the generally low emissivity of metals and the thermally noisy environment typically encountered in manufacturing plants. In this paper we present results of an investigation that explores the suitability of active IR imaging of powder metallurgy compacts for the detection of surface and sub-surface defects in the pre-sinter state and in an on-line manufacturing setting to ensure complete quality assurance. Additional off-line tests can be carried out for statistical quality analyses. In this research, the IR imaging of sub-surface defects is based on a transient instrumentation approach that relies on an electric control system which synchronizes and monitors the thermal response due to an electrically generated heat source. Preliminary testing reveals that this newly developed pulsed thermography system can be employed for the detection of subsurface defects in green-state parts. Practical measurements agree well with theoretical predictions. The inspection approach being developed can be used for the testing of green-state compacts as they exit the compaction press at speeds of up to 1,000 parts per hour

  6. Ensuring Equal Access to High-Quality Education. Revised

    Science.gov (United States)

    Office for Civil Rights, US Department of Education, 2011

    2011-01-01

    The Office for Civil Rights (OCR) in the U.S. Department of Education (Department) is a law enforcement agency charged with enforcing federal civil rights laws to ensure that educational institutions receiving federal financial assistance do not engage in discriminatory conduct. OCR enforces the federal civil rights laws that prohibit…

  7. Detection of nuclear testing from surface concentration measurements: Analysis of radioxenon from the February 2013 underground test in North Korea

    Science.gov (United States)

    Kurzeja, R. J.; Buckley, R. L.; Werth, D. W.; Chiswell, S. R.

    2018-03-01

    A method is outlined and tested to detect low level nuclear or chemical sources from time series of concentration measurements. The method uses a mesoscale atmospheric model to simulate the concentration signature from a known or suspected source at a receptor which is then regressed successively against segments of the measurement series to create time series of metrics that measure the goodness of fit between the signatures and the measurement segments. The method was applied to radioxenon data from the Comprehensive Test Ban Treaty (CTBT) collection site in Ussuriysk, Russia (RN58) after the Democratic People's Republic of Korea (North Korea) underground nuclear test on February 12, 2013 near Punggye. The metrics were found to be a good screening tool to locate data segments with a strong likelihood of origin from Punggye, especially when multiplied together to a determine the joint probability. Metrics from RN58 were also used to find the probability that activity measured in February and April of 2013 originated from the Feb 12 test. A detailed analysis of an RN58 data segment from April 3/4, 2013 was also carried out for a grid of source locations around Punggye and identified Punggye as the most likely point of origin. Thus, the results support the strong possibility that radioxenon was emitted from the test site at various times in April and was detected intermittently at RN58, depending on the wind direction. The method does not locate unsuspected sources, but instead, evaluates the probability of a source at a specified location. However, it can be extended to include a set of suspected sources. Extension of the method to higher resolution data sets, arbitrary sampling, and time-varying sources is discussed along with a path to evaluate uncertainty in the calculated probabilities.

  8. A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse

    Science.gov (United States)

    Walczak, Rafał; Krüger, Jan; Moynihan, Shane

    2015-08-01

    In this paper, we describe a miniaturised image-based fluorescence detection system and demonstrate its viability as a highly sensitive tool for point-of-care-analysis of drugs of abuse in human sweat with a focus on monitor individuals for drugs of abuse. Investigations of miniaturised and low power optoelectronic configurations and methodologies for real-time image analysis were successfully carried out. The miniaturised fluorescence detection system was validated against a reference detection system under controlled laboratory conditions by analysing spiked sweat samples in dip stick and then strip with sample pad. As a result of the validation studies, a 1 ng mL-1 limit of detection of cocaine in sweat and full agreement of test results with the reference detection system can be reported. Results of the investigations open the way towards a detection system that integrates a hand-held fluorescence reader and a wearable skinpatch, and which can collect and in situ analyse sweat for the presence of cocaine at any point for up to tenths hours.

  9. Development of real-time PCR tests for the detection of Tenebrio molitor in food and feed.

    Science.gov (United States)

    Debode, Frédéric; Marien, Aline; Gérard, Amaury; Francis, Frédéric; Fumière, Olivier; Berben, Gilbert

    2017-08-01

    Insects are rich in proteins and could be an alternative source of proteins to feed animals and humans. Numerous companies have started the production of insects for feed purposes. In Europe, these processed animal proteins are not yet authorised by legislation as many questions still need to be answered concerning this 'novel food'. Authorisations will be possible when methods of authentication of the products are available. In this study we propose real-time PCR methods for the specific detection of the mealworm (Tenebriomolitor), one of the most widely used insects for food and feed production. Two PCR assays are proposed: the first based on the wingless gene and the second based on the cadherin gene. The PCR tests amplify fragments of 87 bp. These qualitative methods were tested according to several performance criteria. The specificity was tested on 34 insect species' DNA, but also on non-insect species including crustacean, mammals, birds and plants. The limit of detection was determined and was below 20 copies for the two PCR tests. The applicability of the tests was demonstrated by the analysis of real-life processed samples containing T. molitor.

  10. Ultrasensitive leak detection during ultrahigh vacuum evacuation by quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Chen Xu; Huang Tianbin; Wang Ligong; Jin Qiji; Cha Liangzhen

    2006-01-01

    One must do ultrasensitive leak detection during ultrahigh-vacuum (UHV) evacuation, especially just before the device is sealed off from the vacuum system, to guarantee the longevity of the sealed high-vacuum or even UHV devices with small volume. A quadrupole mass spectrometer (QMS) with an UHV evacuation system can be used under accumulation mode to do the testing. Possible accumulate modes, as well as their advantages and shortcomings, are studied experimentally and discussed in this paper. We found that the opening action of the metal valve during accumulation mode always severely affects the height of the peak indicated by QMS and causes considerable errors. If we determine the leak rate by the peak area instead of the peak height, the situation is much improved. This method has proven quite useful in ensuring the tightness quality for complex sealed UHV devices with small volumes. Ultrasensitive leak detection has been carried out for such real evacuating devices, and a leak rate of 2x10 -14 Pa·m 3 /s was detected, which is far lower than its dynamic mode and the detection limit of the current advanced commercial leak detectors

  11. Program for generating tests for the detection of failures in combinatorial logic systems

    International Nuclear Information System (INIS)

    Mansour, Mounir

    1972-01-01

    A method for generating test sequences for detecting failures in combinatorial logic systems, is described. It relies on: the splitting of these systems into elements of NOR and NAND circuits, the propagation of the failure state from the input to the output. Test sequences generation is achieved in two steps: a first one called chaining during which are investigated the propagation paths of an input state able to show off failures, a second one called consistency during which the global state of the circuit related to this input configuration is held to the wanted state so that the propagation takes place. (author) [fr

  12. Enhancing Scientific Foundations to Ensure Reproducibility: A New Paradigm.

    Science.gov (United States)

    Hsieh, Terry; Vaickus, Max H; Remick, Daniel G

    2018-01-01

    Progress in science is dependent on a strong foundation of reliable results. The publish or perish paradigm in research, coupled with an increase in retracted articles from the peer-reviewed literature, is beginning to erode the trust of both the scientific community and the public. The NIH is combating errors by requiring investigators to follow new guidelines addressing scientific premise, experimental design, biological variables, and authentication of reagents. Herein, we discuss how implementation of NIH guidelines will help investigators proactively address pitfalls of experimental design and methods. Careful consideration of the variables contributing to reproducibility helps ensure robust results. The NIH, investigators, and journals must collaborate to ensure that quality science is funded, explored, and published. Copyright © 2018 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  13. Radiation processing of leafy vegetables to ensure their microbial safety

    International Nuclear Information System (INIS)

    Khade, H.D.; Jain, M.P.; Satyendra, Gautam

    2015-01-01

    Leafy vegetables which are consumed in raw form such as spinach, coriander and mint were found to be heavily burdened with microbial load including presumptive coliform, an indicator of pathogenic contaminations. Total aerobic plate counts in fresh spinach, coriander and mint samples collected from different location of Mumbai and nearby cities were found to be in the order of ∼ 10 7 to ∼ 10 8 CFU/g. In these samples yeast and mould count was in the order of ∼10 5 CFU/g and presumptive coliform in the order of ∼ 10 4 to ∼10 5 CFU/g. As per USFDA coliform load in the food commodity should be nil. The finding thus indicates that these fresh vegetables are not safe for raw consumption. Hence there is utmost need of process which can ensure the safety by reducing their microbial load below permissible level (<10 4 CFU/gm) and coliform load to nil without affecting the appearance and quality of such produce. In this study gamma radiation was used for hygienization of leafy vegetables. The sample were first cleaned in potable water followed by sodium hypochlorite wash (200 ppm for 20 min), air dried, packed in styrofoam based tray, wrapped with cling film and radiation processed at 1 to 2.5 kGy and stored at 4 and 10℃ . Post irradiation microbiological analysis of radiation processed samples was carried out at in 2 kGy irradiated samples total plate count was below ∼10 3 CFU/g and presumptive coliform count was below detectable level. Yeast and mould count in these samples also reduced to below ∼ 10 3 CFU/g. Based on the study the following combination treatment can be given to raw leafy vegetables, washing with potable water (5 min) → sodium hypochlorite (200 ppm 20 min) wash → Air drying → Packaging in styrofoam based tray and wrapping with cling film → Irradiation at 2 kGy → storage at 4℃ . Besides ensuring safety the treatment also resulted in increased shelf life extension of the commodities up to 20 days. (author)

  14. Ensuring the security and availability of a hospital wireless LAN system.

    Science.gov (United States)

    Hanada, Eisuke; Kudou, Takato; Tsumoto, Shusaku

    2013-01-01

    Wireless technologies as part of the data communication infrastructure of modern hospitals are being rapidly introduced. Even though there are concerns about problems associated with wireless communication security, the demand is remarkably large. Herein we discuss security countermeasures that must be taken and issues concerning availability that must be considered to ensure safe hospital/business use of wireless LAN systems, referring to the procedures introduced at a university hospital. Security countermeasures differ according to their purpose, such as preventing illegal use or ensuring availability, both of which are discussed. The main focus of the availability discussion is on signal reach, electromagnetic noise elimination, and maintaining power supply to the network apparatus. It is our hope that this information will assist others in their efforts to ensure safe implementation of wireless LAN systems, especially in hospitals where they have the potential to greatly improve information sharing and patient safety.

  15. Utility of a rapid immunochromatographic strip test in detecting canine parvovirus infection compared with polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Sundaran S. Tinky

    2015-04-01

    Full Text Available Aim: The present study was undertaken to detect the presence of canine parvovirus (CPV in fecal samples of diarrheic dogs by conventional polymerase chain reaction (PCR and immunochromatographic (IC strip test and to compare the diagnostic potential of these tests. Materials and Methods: A total of 50 fecal samples collected from diarrheic dogs suspected for CPV infection were subjected to PCR using CPV-555 primer amplifying the gene coding for the VP1 protein. These samples were also tested by IC strip test using a commercial rapid Ag test kit. The results were statistically analyzed using McNemar test. Results: A total of 22 samples (44% were detected as positive by PCR, which yielded a specific amplicon of 583 bp. In IC strip test, 18 (36% samples were found to be positive. The sensitivity of the test as compared to PCR was found to be 72.22% and specificity was 92.86%. Positive predictive value and negative predictive value of IC strip test was found to be 88.89% and 81.25%, respectively. Statistical analysis of the results of PCR and IC assay using McNemar test revealed no significant difference (p>0.05. Conclusion: The IC strip test could be employed as a rapid field level diagnostic tool for the diagnosis of canine parvoviral diarrhea.

  16. When interference helps: Increasing executive load to facilitate deception detection in the Concealed Information Test

    Directory of Open Access Journals (Sweden)

    George eVisu-Petra

    2013-03-01

    Full Text Available The possibility to enhance the detection efficiency of the Concealed Information Test (CIT by increasing executive load was investigated, using an interference design. After learning and executing a mock crime scenario, subjects underwent three deception detection tests: an RT-based CIT, an RT-based CIT plus a concurrent memory task (CITMem, and an RT-based CIT plus a concurrent set-shifting task (CITShift. The concealed information effect, consisting in increased RT and lower response accuracy for probe items compared to irrelevant items, was evidenced across all three conditions. The group analyses indicated a larger difference between RTs to probe and irrelevant items in the dual-task conditions, but this difference was not translated in a significantly increased detection efficiency at an individual level. Signal detection parameters based on the comparison with a simulated innocent group showed accurate discrimination for all conditions. Overall response accuracy on the CITMem was highest and the difference between response accuracy to probes and irrelevants was smallest in this condition. Accuracy on the concurrent tasks (Mem and Shift was high, and responses on these tasks were significantly influenced by CIT stimulus type (probes vs. irrelevants. The findings are interpreted in relation to the cognitive load/dual-task interference literature, generating important insights for research on the involvement of executive functions in deceptive behavior.

  17. Detection and mitigation of aging and service wear effects of nuclear power plant components in Canada

    International Nuclear Information System (INIS)

    Pachner, J.

    1987-07-01

    In Canada, the operational safety management of nuclear power plants employs methods which are intended to prevent, detect, correct and mitigate system and component failures from any cause, including the effects of aging and service wear degradation. The paper gives an overview of the application of these methods in the detection and mitigation of aging effects before they impact on plant safety and production reliability. Regulatory audits of these methods, to ensure that an acceptable level of plant safety is maintained by the nuclear power plant licensees, are also described. The methods are: a preventive maintenance program, Significant Event Reporting system, and a reliability based assessment of performance of safety related systems. The above methods are discussed and illustrated by examples. The soundness of the approach has been proven by the results achieved in 163 reactor-years of operation. Present and future developments include reviews of current monitoring, testing and inspection methods to ensure that appropriate time variant parameters (capable of revealing aging degradation before loss of functional capability) are monitored, and reviews of the effectiveness of existing maintenance programs and methods in mitigating aging and service wear effects

  18. Development of Photostimulated Luminescence Technique for Detecting Irradiated Food

    International Nuclear Information System (INIS)

    Ros Anita Ahmad Ramli; Ahmad Zainuri Mohd Dzomir; Zainon Othman; Wan Saffiey Wan Abdullah; Muhamad Samudi Yasir

    2015-01-01

    The exposure of food to ionizing radiation is being progressively used in many countries to inactivate food pathogens, to eradicate pests and to extend shelf-life of food. To ensure free consumer choice, irradiated food will be labeled. The availability of a reliable method to detect irradiated food is important to enforce legal controls on labeling requirements, ensure proper distribution and increase consumer confidence. This paper reports on the preliminary application of photostimulated luminescence technique (PSL) as a potential method to detect irradiated food and perhaps be used for monitoring irradiated food on sale locally in the near future. Thus this study will be beneficial and relevant for application of food irradiation towards improving food safety and security in Malaysia. (author)

  19. ExEP yield modeling tool and validation test results

    Science.gov (United States)

    Morgan, Rhonda; Turmon, Michael; Delacroix, Christian; Savransky, Dmitry; Garrett, Daniel; Lowrance, Patrick; Liu, Xiang Cate; Nunez, Paul

    2017-09-01

    EXOSIMS is an open-source simulation tool for parametric modeling of the detection yield and characterization of exoplanets. EXOSIMS has been adopted by the Exoplanet Exploration Programs Standards Definition and Evaluation Team (ExSDET) as a common mechanism for comparison of exoplanet mission concept studies. To ensure trustworthiness of the tool, we developed a validation test plan that leverages the Python-language unit-test framework, utilizes integration tests for selected module interactions, and performs end-to-end crossvalidation with other yield tools. This paper presents the test methods and results, with the physics-based tests such as photometry and integration time calculation treated in detail and the functional tests treated summarily. The test case utilized a 4m unobscured telescope with an idealized coronagraph and an exoplanet population from the IPAC radial velocity (RV) exoplanet catalog. The known RV planets were set at quadrature to allow deterministic validation of the calculation of physical parameters, such as working angle, photon counts and integration time. The observing keepout region was tested by generating plots and movies of the targets and the keepout zone over a year. Although the keepout integration test required the interpretation of a user, the test revealed problems in the L2 halo orbit and the parameterization of keepout applied to some solar system bodies, which the development team was able to address. The validation testing of EXOSIMS was performed iteratively with the developers of EXOSIMS and resulted in a more robust, stable, and trustworthy tool that the exoplanet community can use to simulate exoplanet direct-detection missions from probe class, to WFIRST, up to large mission concepts such as HabEx and LUVOIR.

  20. Review of Literature on Probability of Detection for Magnetic Particle Nondestructive Testing

    Science.gov (United States)

    2013-01-01

    a precipitation hardened martensitic stainless steel . The inspections were based on MIL-STD-1949A [51], now superseded but current at the time...inspector population involved in the tests, it is not possible to draw any further conclusions.  MPT of flat 17-4PH stainless steel plates. A brief...inspection method used to detect surface-breaking cracks in high-strength steel components. A survey of the available literature on the reliability

  1. Strategies for Ensuring Trustworthiness in Qualitative Research Projects

    Science.gov (United States)

    Shenton, Andrew K.

    2004-01-01

    Although many critics are reluctant to accept the trustworthiness of qualitative research, frameworks for ensuring rigour in this form of work have been in existence for many years. Guba's constructs, in particular, have won considerable favour and form the focus of this paper. Here researchers seek to satisfy four criteria. In addressing…

  2. The comparison of the unit test tools JUnit and TestNG

    OpenAIRE

    Šarkanj, Aleš

    2011-01-01

    Testing holds an important role in developing software. It is a process ensuring software works as expected. An important part of testing is unit testing as the basic testing level. The purpose of this thesis is comparing JUnit and TestNG, two of the most popular unit testing tools in Java. In the first part we will present testing and its purpose within software development. We will also present the basic terminology and levels of testing. Further on the area of unit testing will be pr...

  3. A comparison of three tests to detect feigned amnesia: The effects of feedback and the measurement of response latency

    NARCIS (Netherlands)

    Bolan, Barbara; Foster, Jonathan K.; Schmand, Ben; Bolan, Steve

    2002-01-01

    Three experiments provided validation data for an English language version of the Amsterdam Short Term Memory Test (ASTM test) developed to detect feigned memory impairment. Using a simulation design, the ASTM test compared favourably with the Test of Memory Malingering (TOMM) and appeared better

  4. Intraesophageal pressure recording improves the detection of cough during multichannel intraluminal impedance testing in children.

    Science.gov (United States)

    Rosen, Rachel; Amirault, Janine; Giligan, Emily; Khatwa, Umakanth; Nurko, Samuel

    2014-01-01

    One of the primary reasons for referral for reflux testing is to correlate reflux events with symptoms such as cough. Adult studies have suggested that symptom recording is flawed and pediatricians feel this is an even more significant problem because there may be errors in both parental and patient reports. We hypothesize that intraesophageal pressure recording (IEPR) provides an objective method to identify coughs during reflux testing in children. We recruited 20 children undergoing multichannel intraluminal impedance with pH (pH-MII) testing for the evaluation of cough. We placed simultaneous intraesophageal pressure and pH-MII catheters. Tracings were blindly scored by 2 observers without knowledge of patient/parent symptom report. After the blinded scoring, patient/parent report of symptoms was recorded. Ninety-four percent of all coughs were detected by IEPR and only 48% of all coughs were reported by patients/parents. The mean time from the IEPR cough to the patient/parent cough was 11±16 seconds. Using IEPR as the criterion standard for the detection of cough, the sensitivity of patient report for the detection of cough is 46%. Using varying symptom windows because of the increased precision of IEPR, the number of patients with a positive symptom index could be reduced from 30% to 0%, preventing children from being falsely categorized as having reflux-related lung disease. Parental and patient symptom recording in children is inadequate for making the diagnosis of reflux-related lung disease. If patients undergo pH-MII testing for reflux-related cough, IEPR should become the new standard by which to correlate reflux with cough.

  5. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  6. 49 CFR 180.509 - Requirements for inspection and test of specification tank cars.

    Science.gov (United States)

    2010-10-01

    ...) Radiography test; (3) Magnetic particle test; (4) Ultrasonic test; or (5) Optically-aided visual inspection (e...) Testing the reclosing pressure relief device with air or another gas to ensure that it conforms to the... inoperative. The written procedures and test method for leak testing must ensure for the sensitivity and...

  7. Robust mitotic entry is ensured by a latching switch

    Directory of Open Access Journals (Sweden)

    Chloe Tuck

    2013-07-01

    Cell cycle events are driven by Cyclin dependent kinases (CDKs and by their counter-acting phosphatases. Activation of the Cdk1:Cyclin B complex during mitotic entry is controlled by the Wee1/Myt1 inhibitory kinases and by Cdc25 activatory phosphatase, which are themselves regulated by Cdk1:Cyclin B within two positive circuits. Impairing these two feedbacks with chemical inhibitors induces a transient entry into M phase referred to as mitotic collapse. The pathology of mitotic collapse reveals that the positive circuits play a significant role in maintaining the M phase state. To better understand the function of these feedback loops during G2/M transition, we propose a simple model for mitotic entry in mammalian cells including spatial control over Greatwall kinase phosphorylation. After parameter calibration, the model is able to recapture the complex and non-intuitive molecular dynamics reported by Potapova et al. (Potapova et al., 2011. Moreover, it predicts the temporal patterns of other mitotic regulators which have not yet been experimentally tested and suggests a general design principle of cell cycle control: latching switches buffer the cellular stresses which accompany cell cycle processes to ensure that the transitions are smooth and robust.

  8. Robust mitotic entry is ensured by a latching switch.

    Science.gov (United States)

    Tuck, Chloe; Zhang, Tongli; Potapova, Tamara; Malumbres, Marcos; Novák, Béla

    2013-01-01

    Cell cycle events are driven by Cyclin dependent kinases (CDKs) and by their counter-acting phosphatases. Activation of the Cdk1:Cyclin B complex during mitotic entry is controlled by the Wee1/Myt1 inhibitory kinases and by Cdc25 activatory phosphatase, which are themselves regulated by Cdk1:Cyclin B within two positive circuits. Impairing these two feedbacks with chemical inhibitors induces a transient entry into M phase referred to as mitotic collapse. The pathology of mitotic collapse reveals that the positive circuits play a significant role in maintaining the M phase state. To better understand the function of these feedback loops during G2/M transition, we propose a simple model for mitotic entry in mammalian cells including spatial control over Greatwall kinase phosphorylation. After parameter calibration, the model is able to recapture the complex and non-intuitive molecular dynamics reported by Potapova et al. (Potapova et al., 2011). Moreover, it predicts the temporal patterns of other mitotic regulators which have not yet been experimentally tested and suggests a general design principle of cell cycle control: latching switches buffer the cellular stresses which accompany cell cycle processes to ensure that the transitions are smooth and robust.

  9. Steam leak detection in advance reactors via acoustics method

    International Nuclear Information System (INIS)

    Singh, Raj Kumar; Rao, A. Rama

    2011-01-01

    Highlights: → Steam leak detection system is developed to detect any leak inside the reactor vault. → The technique uses leak noise frequency spectrum for leak detection. → Testing of system and method to locate the leak is also developed and discussed in present paper. - Abstract: Prediction of LOCA (loss of coolant activity) plays very important role in safety of nuclear reactor. Coolant is responsible for heat transfer from fuel bundles. Loss of coolant is an accidental situation which requires immediate shut down of reactor. Fall in system pressure during LOCA is the trip parameter used for initiating automatic reactor shut down. However, in primary heat transport system operating in two phase regimes, detection of small break LOCA is not simple. Due to very slow leak rates, time for the fall of pressure is significantly slow. From reactor safety point of view, it is extremely important to find reliable and effective alternative for detecting slow pressure drop in case of small break LOCA. One such technique is the acoustic signal caused by LOCA in small breaks. In boiling water reactors whose primary heat transport is to be driven by natural circulation, small break LOCA detection is important. For prompt action on post small break LOCA, steam leak detection system is developed to detect any leak inside the reactor vault. The detection technique is reliable and plays a very important role in ensuring safety of the reactor. Methodology developed for steam leak detection is discussed in present paper. The methods to locate the leak is also developed and discussed in present paper which is based on analysis of the signal.

  10. Cep63 and cep152 cooperate to ensure centriole duplication.

    Directory of Open Access Journals (Sweden)

    Nicola J Brown

    Full Text Available Centrosomes consist of two centrioles embedded in pericentriolar material and function as the main microtubule organising centres in dividing animal cells. They ensure proper formation and orientation of the mitotic spindle and are therefore essential for the maintenance of genome stability. Centrosome function is crucial during embryonic development, highlighted by the discovery of mutations in genes encoding centrosome or spindle pole proteins that cause autosomal recessive primary microcephaly, including Cep63 and Cep152. In this study we show that Cep63 functions to ensure that centriole duplication occurs reliably in dividing mammalian cells. We show that the interaction between Cep63 and Cep152 can occur independently of centrosome localisation and that the two proteins are dependent on one another for centrosomal localisation. Further, both mouse and human Cep63 and Cep152 cooperate to ensure efficient centriole duplication by promoting the accumulation of essential centriole duplication factors upstream of SAS-6 recruitment and procentriole formation. These observations describe the requirement for Cep63 in maintaining centriole number in dividing mammalian cells and further establish the order of events in centriole formation.

  11. Automatic Threshold Determination for a Local Approach of Change Detection in Long-Term Signal Recordings

    Directory of Open Access Journals (Sweden)

    David Hewson

    2007-01-01

    Full Text Available CUSUM (cumulative sum is a well-known method that can be used to detect changes in a signal when the parameters of this signal are known. This paper presents an adaptation of the CUSUM-based change detection algorithms to long-term signal recordings where the various hypotheses contained in the signal are unknown. The starting point of the work was the dynamic cumulative sum (DCS algorithm, previously developed for application to long-term electromyography (EMG recordings. DCS has been improved in two ways. The first was a new procedure to estimate the distribution parameters to ensure the respect of the detectability property. The second was the definition of two separate, automatically determined thresholds. One of them (lower threshold acted to stop the estimation process, the other one (upper threshold was applied to the detection function. The automatic determination of the thresholds was based on the Kullback-Leibler distance which gives information about the distance between the detected segments (events. Tests on simulated data demonstrated the efficiency of these improvements of the DCS algorithm.

  12. D-dimer as an applicable test for detection of posttraumatic deep vein thrombosis in lower limb fracture.

    Science.gov (United States)

    Bakhshi, Hooman; Alavi-Moghaddam, Mostafa; Wu, Karin C; Imami, Mohammad; Banasiri, Mohammad

    2012-06-01

    Measuring the plasma levels of D-dimer is an accurate and easy modality to detect deep vein thrombosis (DVT) in nontraumatic settings. However, the diagnostic reliability of D-dimer assays in detecting posttraumatic DVT among patients with lower limb fracture undergoing orthopedic surgery is not validated. In this study, 141 patients with lower limb fracture admitted through the emergency department and undergoing orthopedic surgery were enrolled. Postoperative venous blood samples for D-dimer assay were taken on the 1st, 7th, and 28th postoperative days. Color Doppler sonography examination of both lower limbs was performed at the same time as a standard test. Eight out of the 141 patients (6%) had acute DVT based on Color Doppler sonography. Mean D-dimer was 2160 ng/mL in DVT positive patients and 864 in DVT negative patients. D-dimer levels greater than 1000 ng/mL were 100% sensitive and 71% specific for detecting postoperative DVT. D-dimer assay is a useful and sensitive test for detecting posttraumatic DVT.

  13. Detection of clarithromycin-resistant Helicobacter pylori by polymerase chain reaction using residual samples from rapid urease test

    Directory of Open Access Journals (Sweden)

    Jae-Sik Jeon

    2017-01-01

    Full Text Available Background: Approximately 50% of the world population is infected with Helicobacter pylori, which corresponds to a high infection rate. Furthermore, the incidence of antibiotic-resistant H. pylori has increased with the recent rise in use of antibiotics for H. pylori elimination, suggesting growing treatment failures. Aim: The study was aimed to assess the use of residual samples from rapid urease test (RUT for biomolecular testing as an effective and accurate method to detect antibiotic-resistant H. pylori. Settings and Design: This study was a retrospective study performed using data obtained from medical records of previously isolated H. pylori strains. Materials and Methods: RUT was conducted for 5440 biopsy samples from individuals who underwent health examination in South Korea. Subsequently, 469 RUT residual samples were randomly selected and subjected to polymerase chain reaction (PCR to detect antibiotic-resistant H. pylori. Statistical Analysis Used: The Chi-square test was used to analyse categorical data. P < 0.05 was considered statistically significant. Results: The results showed a concordance between the results of PCR and conventional RUT in 450 of 469 samples, suggesting that the H. pylori PCR test is a time- and cost-effective detection method. Conclusions: This study demonstrated that PCR test can aid physicians to prescribe the appropriate antibiotics at the time of diagnosis, thus preventing the reduction in H. pylori eradication due to antibiotic resistance, averting progression to serious diseases and increasing the treatment success rate.

  14. Simple screening tests for the detection of metallo-β-lactamase (MBL production in clinical isolates of Pseudomonas and Acinetobacter

    Directory of Open Access Journals (Sweden)

    Shaheda Anwar

    2010-01-01

    Full Text Available There are no standard methods for the detection of metallo-b-lactamase (MBL production in gram negative organism in routine microbiology practice. The present study was undertaken to evaluate the screening tests like double disk synergy test (DDST and disk potentiation test (DPT using ceftazidime (CAZ and imipenem (IPM disks with chelating agents like EDTA, 2-mercaptopropionic acid (2-MPA. A total of 132 Pseudomonas and 76 Acinetobacter isolates were obtained from Bangabandhu Sheikh Mujib Medical University (BSMMU and Bangladesh Institute of Research and Rehabilitation for Diabetes, Endocrine and Metabolic Disorders (BIRDEM hospitals of Dhaka city. A total of 53 and 29 IPM resistant Pseudomonas and Acinetobacter isolates were selected. EDTA-IPM microdilution minimum inhibitory concentration (EDTA-IPM MIC method detected MBL in 44 (83% IPM resistant Pseudomonas and 19 (65.5% Acinetobacter isolates. DDST with CAZ-0.1M EDTA and CAZ-2-MPA detected MBL in 73.6% and 67.9% of IPM resistant Pseudomonas and 55.2% and 48.3% of Acinetobacter isolates respectively. The detection rate was 67.9% and 66.1% in Pseudomonas and 51.7% and 44.8% in Acinetobacter isolates by EDTA-IPM and IPM-2-MPA methods respectively. In comparison to DDST, DPT with CAZ-0.1M EDTA showed higher sensitivity (89.7% and specificity (100% for detection of MBL in Pseudomonas and Acinetobacter. The results showed that simple screening tests like DPT with 0.1M EDTA was able to detect MBL producing Pseudomonas and Acinetobacter from clinical samples with high sensitivity and specificity. Ibrahim Med. Coll. J. 2010; 4(1: 26-30

  15. Over-the-counter human immunodeficiency virus self-test kits: time to explore their use for men who have sex with men in Brazil

    Directory of Open Access Journals (Sweden)

    Sheri A. Lippman

    2014-05-01

    Full Text Available Increasing access and frequency of human immunodeficiency virus testing are critical to stemming the epidemic. In Brazil's concentrated epidemic, human immunodeficiency virus prevalence in the men who have sex with men/transgender population far exceeds that in the general population, but testing rates fall below what is needed to ensure early detection and treatment. Over-the-counter human immunodeficiency virus self-testing kits, now available in stores in the U.S., have enormous potential to increase testing access and frequency and to facilitate early detection and treatment. With the advent of human immunodeficiency virus self-testing upon us, it is timely to engage the scientific community, government, and civil society in a dialog around how to best utilize this technology in Brazil. We summarize recent research on over-the-counter testing among men who have sex with men, raise potential questions and challenges to using self-tests, suggest implementation strategies, and outline a research agenda moving forward.

  16. Role of Head Teachers in Ensuring Sound Climate

    Science.gov (United States)

    Kor, Jacob; Opare, James K.

    2017-01-01

    The school climate is outlined in literature as one of the most important within school factors required for effective teaching in learning. As leaders in any organisations are assigned the role of ensuring sound climates for work, head teachers also have the task of creating and maintaining an environment conducive for effective academic work…

  17. Solid-phase enzyme immunoassay or radioimmunoassay for the detection of immune complexes based on their recognition by conglutinin: conglutinin-binding test

    International Nuclear Information System (INIS)

    Casali, P.; Bossus, A.; Carpentier, N.A.; Lambert, P.H.

    1977-01-01

    Bovine conglutinin was used in a solid-phase assay for the detection of immune complexes. In a first step, the tested serum sample was incubated in polypropylene tubes coated with conglutinin to allow C3-coated immune complexes to bind to solid-phase conglutinin. In a second step, the conglutinin-bound complexes were detected using an enzyme-conjugated or radiolabelled anti-immunoglobulin antibody. The conglutinin-binding (KgB) test did not suffer from the interference of DNA, heparin or endotoxins. Its limit of sensitivity for aggregated IgG was 3 μg/ml undiluted human serum. Immune complexes prepared in vitro using tetanus toxoid, or DNA, and corresponding antibodies in human sera could be detected at various antigen/antibody ratios and at antibody concentrations lower than 8 μg/ml. The KgB test allowed for the detection of immune complexes in sera from patients with systemic lupus erythematosus, rheumatoid arthritis, idiopathic vasculitis, leprosy and leukemia. These sera were also tested using the 125 I-labelled Clq-binding activity (BA) test and the KgB test simultaneously, and a significant rank order correlation was observed. In patients with leukemia, a significant correlation was observed using three tests, KgB, 125 I-labelled Clq BA and Raji-cell radioimmunoassay (RIA). Therefore, the KgB test appears as a simple and reproducible method, utilizing a very stable reagent, with a sensitivity and specificity comparable to the other tests studied and allowing for clinical application. (author)

  18. [Ensure - complete and balanced nutrition, convenient on work].

    Science.gov (United States)

    Kurenkov, A V; Iuriatin, A A

    2013-01-01

    The work conditions often may compromise a company ability to supply their employees with adequate, hot meals. For heavy labor workers and some office employees it is important to restore energy and nutrients with food, balanced in nutrients. The lack of adequate nutritive support can give a negative impact on different organs functions. One of the main principles of healthy nutrition is - diet must be balanced in nutrients. Which is easy to say, but difficult to implement, especially on some industries. Complete and balanced liquid and ready-to-use nutrition is new trend in nutrition of healthy people who cannot consume optimal diet, and in people with the risk of nutrient deficiencies. One-two packs of Ensure daily can significantly improve a worker ration. 2 and more packs could serve as a real complete and balanced lunch (>or=780 kcal). Also Ensure is easy to store and to deliver in distant places of work and can be recommended for use as a convenient, complete and balanced nutrition on work.

  19. FACTOR IN ENSURING A BALANCED BUDGET NORTHERN TERRITORIES

    Directory of Open Access Journals (Sweden)

    Tatiana Anatol’evna Naidenova

    2016-02-01

    Full Text Available The main tools of sustainable development of the country as a whole and its individual regions are federal and regional budgets. At the same time a prerequisite for the use of this tool is its equilibrium. It is the basic principle of a responsible fiscal policy. The article describes the factors to equilibrium. on the budgets of the northern regions of the Russian Federation. The measures to ensure budgetary equilibrium in the northern regions of the Russian Federation are offered.The purpose of the article. Substantiating the measures to balance the budgets of the northern Russian Federation subjects on the basis of analysis of the factors that directly affect the mobilization of potential tax revenues to regional budgets.Method and methodology of work. Theoretical and empirical methods, analysis, synthesis, induction, deduction.Results of the study. To ensure factors unbalanced budgets northern territories. The proposals the balance of revenues and expenditures of the regional budgets of the northern regions of the Russian Federation are submitted.Application area. Finance authorities of subjects of the Russian Federation.

  20. Detection of cavitation inception by acoustic technique in centrifugal pumps for nuclear application

    International Nuclear Information System (INIS)

    Prakash, V.; Prabhakar, R.; Rao, A.S.L.K.; Kale, R.D.

    1994-01-01

    The primary centrifugal pumps in a pool type reactor like the proposed Prototype Fast Breeder Reactor (PFBR) are required to operate at low values of available net positive suction head due to the limited submergence available in the pool. Pump hydraulics are designed to ensure that there is no cavitation or only minimum cavitation in the pump impeller in order to minimise long term erosion damage. Rigorous cavitation tests are usually carried out during development and final testing phase and a promising cavitation detection technique lies in acoustic noise measurements on the pump. As part of PFBR pump development programme, cavitation noise measurements were initially carried out on an experimental sodium pump in a water rig to establish detection procedures. Recently cavitation noise measurements were carried out on a 1/3 scale model impeller of PFBR pump along with visual observation of impeller passages to establish a correlation between visual and acoustic technique. Accelerometer responding to structure borne noise seems to give the best result. (author). 4 refs., 6 figs

  1. Set-membership fault detection under noisy environment with application to the detection of abnormal aircraft control surface positions

    Science.gov (United States)

    El Houda Thabet, Rihab; Combastel, Christophe; Raïssi, Tarek; Zolghadri, Ali

    2015-09-01

    The paper develops a set membership detection methodology which is applied to the detection of abnormal positions of aircraft control surfaces. Robust and early detection of such abnormal positions is an important issue for early system reconfiguration and overall optimisation of aircraft design. In order to improve fault sensitivity while ensuring a high level of robustness, the method combines a data-driven characterisation of noise and a model-driven approach based on interval prediction. The efficiency of the proposed methodology is illustrated through simulation results obtained based on data recorded in several flight scenarios of a highly representative aircraft benchmark.

  2. Sequential Analysis: Hypothesis Testing and Changepoint Detection

    Science.gov (United States)

    2014-07-11

    maintains the flexibility of deciding sooner than the fixed sample size procedure at the price of some lower power [13, 514]. The sequential probability... markets , detection of signals with unknown arrival time in seismology, navigation, radar and sonar signal processing, speech segmentation, and the... skimming cruise missile can yield a significant increase in the probability of raid annihilation. Furthermore, usually detection systems are

  3. Development of early core anomaly detection system by using in-sodium microphone in JOYO. Fundamental characteristics test of in-sodium microphone in water and examination of improvement of detection accuracy

    International Nuclear Information System (INIS)

    Komai, Masafumi

    2001-07-01

    Fast reactor core anomalies can be detected in near real-time with acoustic sensors. An acoustic detection system senses an in-core anomaly immediately from the fast acoustic signals that propagate through the sodium coolant. One example of a detectable anomaly is sodium boiling due to local blockage in a sub-assembly; the slight change in background acoustic signals can be detected. A key advantage of the acoustic detector is that it can be located outside the core. The location of the anomaly in the core can be determined by correlating multiple acoustic signals. This report describes the testing and fundamental characteristics of a microphone suitable for use in the sodium coolant and examines methods to improve the system's S/N ratio. Testing in water confirmed that the in-sodium microphone has good impulse and wide band frequency responses. These tests used impulse and white noise signals that imitate acoustic signals from boiling sodium. Correlation processing of multiple microphone signals to improve S/N ratio is also described. (author)

  4. Toxicity tests with crustaceans for detecting sublethal effects of potential endocrine disrupting chemicals

    DEFF Research Database (Denmark)

    Wollenberger, Leah

    /antagonistic activity with the ecdysteroid-responsive Drosophila melanogaster BII cell line 6) to draft an OECD guideline proposal for testing of chemicals based on the experimental work performed within this study In preliminary investigations with A. tonsa were studied various parameters related to processes......New and updated test methods to detect and characterise endocrine disrupting chemicals are urgently needed for the purpose of environmental risk assessment. Although endocrine disruption in invertebrates has not been studied as extensive as in vertebrates, in particular in fish, numerous reports...... of the present Ph.D. project were: 1) to develop a fully synthetic saltwater medium suitable for laboratory culturing of marine copepods including their feeding organism as well as for toxicity testing 2) to identify sensitive endpoints related to growth, development and reproduction of the pelagic calanoid...

  5. Live Operation Data Collection Optimization and Communication for the Domestic Nuclear Detection Office's Rail Test Center

    International Nuclear Information System (INIS)

    Gelston, Gariann M.

    2010-01-01

    For the Domestic Nuclear Detection Office's Rail Test Center (i.e., DNDO's RTC), port operation knowledge with flexible collection tools and technique are essential in both technology testing design and implementation intended for live operational settings. Increased contextual data, flexibility in procedures, and rapid availability of information are keys to addressing the challenges of optimization, validation, and analysis within live operational setting data collection. These concepts need to be integrated into technology testing designs, data collection, validation, and analysis processes. A modified data collection technique with a two phased live operation test method is proposed.

  6. Strategy to Ensure Institutional Control Implementation at Superfund Sites

    Science.gov (United States)

    This document sets forth EPA’s strategy (Strategy) for ensuring that institutional controls (ICs) are successfully implemented at Superfund sites, with an emphasis on evaluating ICs at sites where all construction of all remedies is complete (construction complete sites).

  7. [Validity of AUDIT test for detection of disorders related with alcohol consumption in women].

    Science.gov (United States)

    Pérula-de Torres, Luis Angel; Fernández-García, José Angel; Arias-Vega, Raquel; Muriel-Palomino, María; Márquez-Rebollo, Encarnación; Ruiz-Moral, Roger

    2005-11-26

    Early detection of patients with alcohol problems is important in clinical practice. The AUDIT (Alcohol Use Disorders Identification Test) questionnaire is a valid tool for this aim, especially in the male population. The objective of this study was to validate how useful is this questionnaire in females patients and to assess their test cut-off point for the diagnosis of alcohol problems in women. 414 woman were recruited in 2 health center and specialized center for addiction treatment. The AUDIT test and a semistructured interview (SCAN as gold standard) were performed to all patients. Internal consistency and criteria validity was assessed. Cronbach alpha was 0.93 (95% confidence interval [CI], 0.921-0.941). When the DSM-IV was taken as reference the most useful cut-off point was 6 points, with 89.6% (95% CI, 76.11-96.02) sensitivity and 95.07% (95% CI, 92.18-96.97) specificity. When CIE-10 was taken as reference the sensitivity was 89.58% (95% CI, 76.56-96.10) and the specificity was 95.33% (95% CI, 92.48-97.17). AUDIT is a questionnaire with good psychometrics properties and is valid for detecting dependence and risk alcohol consumption in women.

  8. On the importance of developing a new generation of breath tests for Helicobacter pylori detection.

    Science.gov (United States)

    Kushch, Ievgeniia; Korenev, Nikolai; Kamarchuk, Lyudmila; Pospelov, Alexander; Kravchenko, Andrey; Bajenov, Leonid; Kabulov, Mels; Amann, Anton; Kamarchuk, Gennadii

    2015-12-15

    State-of-the-art methods for non-invasive detection of the Helicobacter pylori (H. pylori) infection have been considered. A reported global tendency towards a non-decreasing prevalence of H. pylori worldwide could be co-influenced by the functional limitations of urea breath tests (UBTs), currently preferred for the non-invasive recognition of H. pylori in a clinical setting. Namely, the UBTs can demonstrate false-positive or false-negative results. Within this context, limitations of conventional clinically exploited H. pylori tests have been discussed to justify the existing need for the development of a new generation of breath tests for the detection of H. pylori and the differentiation of pathogenic and non-pathogenic strains of the bacterium. This paper presents the results of a pilot clinical study aimed at evaluating the development and diagnostic potential of a new method based on the detection of the non-urease products of H. pylori vital activity in exhaled gas. The characteristics of breath of adolescents with H. pylori-positive and H. pylori-negative functional dyspepsia, together with a consideration of the cytotoxin-associated gene A (CagA) status of H. pylori-positive subjects, have been determined for the first time using innovative point-contact nanosensor devices based on salts of the organic conductor tetracyanoquinodimethane (TCNQ). The clinical and diagnostic relevance of the response curves of the point-contact sensors was assessed. It was found that the recovery time of the point-contact sensors has a diagnostic value for differentiation of the H. pylori-associated peptic ulcer disease. The diagnostically significant elongation of the recovery time was even more pronounced in patients infected with CagA-positive H. pylori strains compared to the CagA-negative patients. Taking into account the operation of the point-contact sensors in the real-time mode, the obtained results are essential prerequisites for the development of a fast and

  9. A simple and inexpensive point-of-care test for hepatitis B surface antigen detection: serological and molecular evaluation.

    Science.gov (United States)

    Gish, R G; Gutierrez, J A; Navarro-Cazarez, N; Giang, K; Adler, D; Tran, B; Locarnini, S; Hammond, R; Bowden, S

    2014-12-01

    Early identification of chronic hepatitis B is important for optimal disease management and prevention of transmission. Cost and lack of access to commercial hepatitis B surface antigen (HBsAg) immunoassays can compromise the effectiveness of HBV screening in resource-limited settings and among marginalized populations. High-quality point-of-care (POC) testing may improve HBV diagnosis in these situations. Currently available POC HBsAg assays are often limited in sensitivity. We evaluated the NanoSign(®) HBs POC chromatographic immunoassay for its ability to detect HBsAg of different genotypes and with substitutions in the 'a' determinant. Thirty-seven serum samples from patients with HBV infection, covering HBV genotypes A-G, were assessed for HBsAg titre with the Roche Elecsys HBsAg II quantification assay and with the POC assay. The POC assay reliably detected HBsAg at a concentration of at least 50 IU/mL for all genotypes, and at lower concentrations for some genotypes. Eight samples with substitutions in the HBV 'a' determinant were reliably detected after a 1/100 dilution. The POC strips were used to screen serum samples from 297 individuals at risk for HBV in local clinical settings (health fairs and outreach events) in parallel with commercial laboratory HBsAg testing (Quest Diagnostics EIA). POC testing was 73.7% sensitive and 97.8% specific for detection of HBsAg. Although the POC test demonstrated high sensitivity over a range of genotypes, false negatives were frequent in a clinical setting. Nevertheless, the POC assay offers advantages for testing in both developed and resource-limited countries due to its low cost (0.50$) and immediately available results. © 2014 John Wiley & Sons Ltd.

  10. Early warning system for detection of protozoal contamination of source waters

    DEFF Research Database (Denmark)

    Al-Sabi, Mohammad Nafi Solaiman; Mogensen, Claus; Berg, Tommy W.

    2012-01-01

    Ensuring water quality is an ever increasing important issue world-wide. Currently, detection of protozoa in drinking water is a costly and time consuming process. We have developed an online, real-time sensor for detection of Cryptosporidium and Giardia spp. in a range of source waters. The novel...

  11. Online monitoring of steam/water chemistry of a fast breeder test reactor

    International Nuclear Information System (INIS)

    Subramanian, K.G.; Suriyanarayanan, A.; Thirunavukarasu, N.; Naganathan, V.R.; Panigrahi, B.S.; Jambunathan, D.

    2005-01-01

    Operating experience with the once-through steam generator of a fast breeder test reactor (FBTR) has shown that an efficient water chemistry control played a major role in minimizing corrosion related failures of steam generator tubes and ensuring steam generator tube integrity. In order to meet the stringent feedwater and steam quality specifications, use of fast and sensitive online monitors to detect impurity levels is highly desirable. Online monitoring techniques have helped in achieving feedwater of an exceptional degree of purity. Experience in operating the online monitors in the steam/water system of a FBTR is discussed in detail in this paper. In addition, the effect of excess hydrazine in the feedwater on the steam generator leak detection system and the need for a hydrazine online meter are also discussed. (orig.)

  12. Attitudes about regulation among direct-to-consumer genetic testing customers.

    Science.gov (United States)

    Bollinger, Juli Murphy; Green, Robert C; Kaufman, David

    2013-05-01

    The first regulatory rulings by the U.S. Food and Drug Administration on direct-to-consumer (DTC) genetic testing services are expected soon. As the process of regulating these and other genetic tests moves ahead, it is important to understand the preferences of DTC genetic testing customers about the regulation of these products. An online survey of customers of three DTC genetic testing companies was conducted 2-8 months after they had received their results. Participants were asked about the importance of regulating the companies selling DTC genetic tests. Most of the 1,046 respondents responded that it would be important to have a nongovernmental (84%) or governmental agency (73%) monitor DTC companies' claims to ensure the consistency with scientific evidence. However, 66% also felt that it was important that DTC tests be available without governmental oversight. Nearly, all customers favored a policy to ensure that insurers and law enforcement officials could not access their information. Although many DTC customers want access to genetic testing services without restrictions imposed by the government regulation, most also favor an organization operating alongside DTC companies that will ensure that the claims made by the companies are consistent with sound scientific evidence. This seeming contradiction may indicate that DTC customers want to ensure that they have unfettered access to high-quality information. Additionally, policies to help ensure privacy of data would be welcomed by customers, despite relatively high confidence in the companies.

  13. KEY ASPECTS OF ENSURING ENERGY EFFICIENCY OF BUILDINGS AND STRUCTURES

    Directory of Open Access Journals (Sweden)

    S.G. Abramyan

    2017-06-01

    Full Text Available The paper is based on the review of the foreign and national academic literature and intended to emphasize the issues of ensuring energy efficiency of buildings and structures applicable to all the countries as for reconstruction of existing buildings as for erection of new ones . The author highlights the key aspects of the provision of energy efficiency of buildings and structures in some foreign countries. The conclusion is made that the studies are mainly aimed at discovering new heat insulation materials, whereby polystyrene insulation is found to be the most widespread wall insulation material in a number of countries. At the same time, it is observed that the ongoing research is focused on solutions to optimize the structure of walling systems in terms of both insulant thickness and the number and sequence of insulation layers in the walling structure. A conclusion is made that hyper insulation of external walls leads to considerable expenses arising due to cooling during the summer season. The use of prefabricated vacuum panels as a heat insulation layer and off-the-shelf single-layer structures, subject to their heat insulation characteristics, appears a more constructive way to meet the energy efficiency requirements, as the arrangement of ideal air space in multilayered walls proves a significant challenge today. One of the most promising ways to ensure energy efficiency is the use of multifunctional polyvalent walls and provision of polyvalent heat supply from renewable energy sources. Since energy efficiency depends on the spatial arrangement of buildings, construction must ensure a minimum ratio of the area of enclosing structures to the overall building volume (by adding on new facilities in case of reconstruction. It is noted that a systemic approach to ensuring energy efficiency of buildings is impossible without proper regard to the environmental parameters of heat insulation materials.

  14. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  15. Pump testing in the nuclear industry: The comprehensive test and other considerations

    International Nuclear Information System (INIS)

    Hoyle, T.F.

    1992-01-01

    The American Society of Mechanical Engineers Operations and Maintenance Working Group on Pumps and Valves is working on a revision to their pump testing Code, ISTB-1990. This revision will change the basic philosophy of pump testing in the nuclear industry. Currently, all pumps are required to be tested quarterly, except those installed in dry sumps. In the future standby pumps will receive only a start test quarterly to ensure the pump comes up to speed and pressure or flow. Then, on a biennial basis all pumps would receive a more extensive test. This comprehensive test would require high accuracy test gauges to be used, and the pumps would be required to be tested near pump design flow. Testing on minimum flow loops would not be permitted except in rare cases. Additionally. during the comprehensive test, measurements of vibration, flow, and pressure would all be taken. The OM-6 standard (ISTB Code) will also require that reference values of flow rate and differential pressure be taken at several points instead of just one point, which is current practice. The comprehensive test is just one step in ensuring the adequacy of pump testing in the nuclear industry. This paper also addresses other concerns and makes recommendations for increased quality of testing of certain critical pumps and recommendations for less stringent or no tests on less critical pumps

  16. Engineering Sensitivity Improvement of Helium Mass Spectrometer Leak Detection System by Means Global Hard Vacuum Test

    International Nuclear Information System (INIS)

    Sigit Asmara Santa

    2006-01-01

    The engineering sensitivity improvement of Helium mass spectrometer leak detection using global hard vacuum test configuration has been done. The purpose of this work is to enhance the sensitivity of the current leak detection of pressurized method (sniffer method) with the sensitivity of 10 -3 ∼ 10 -5 std cm 3 /s, to the global hard vacuum test configuration method which can be achieved of up to 10 -8 std cm 3 /s. The goal of this research and development is to obtain a Helium leak test configuration which is suitable and can be used as routine bases in the quality control tests of FPM capsule and AgInCd safety control rod products. The result is an additional instrumented vacuum tube connected with conventional Helium mass spectrometer. The pressure and temperature of the test object during the leak measurement are simulated by means of a 4.1 kW capacity heater and Helium injection to test object, respectively. The addition of auxiliary mechanical vacuum pump of 2.4 l/s pumping speed which is directly connected to the vacuum tube, will reduce 86 % of evacuation time. The reduction of the measured sensitivity due to the auxiliary mechanical vacuum pump can be overcome by shutting off the pump soon after Helium mass spectrometer reaches its operating pressure condition. (author)

  17. Kullback-Leibler distance-based enhanced detection of incipient anomalies

    KAUST Repository

    Harrou, Fouzi; Sun, Ying; Madakyaru, Muddu

    2016-01-01

    Accurate and effective anomaly detection and diagnosis of modern engineering systems by monitoring processes ensure reliability and safety of a product while maintaining desired quality. In this paper, an innovative method based on Kullback

  18. Integrated sample-to-detection chip for nucleic acid test assays.

    Science.gov (United States)

    Prakash, R; Pabbaraju, K; Wong, S; Tellier, R; Kaler, K V I S

    2016-06-01

    Nucleic acid based diagnostic techniques are routinely used for the detection of infectious agents. Most of these assays rely on nucleic acid extraction platforms for the extraction and purification of nucleic acids and a separate real-time PCR platform for quantitative nucleic acid amplification tests (NATs). Several microfluidic lab on chip (LOC) technologies have been developed, where mechanical and chemical methods are used for the extraction and purification of nucleic acids. Microfluidic technologies have also been effectively utilized for chip based real-time PCR assays. However, there are few examples of microfluidic systems which have successfully integrated these two key processes. In this study, we have implemented an electro-actuation based LOC micro-device that leverages multi-frequency actuation of samples and reagents droplets for chip based nucleic acid extraction and real-time, reverse transcription (RT) PCR (qRT-PCR) amplification from clinical samples. Our prototype micro-device combines chemical lysis with electric field assisted isolation of nucleic acid in a four channel parallel processing scheme. Furthermore, a four channel parallel qRT-PCR amplification and detection assay is integrated to deliver the sample-to-detection NAT chip. The NAT chip combines dielectrophoresis and electrostatic/electrowetting actuation methods with resistive micro-heaters and temperature sensors to perform chip based integrated NATs. The two chip modules have been validated using different panels of clinical samples and their performance compared with standard platforms. This study has established that our integrated NAT chip system has a sensitivity and specificity comparable to that of the standard platforms while providing up to 10 fold reduction in sample/reagent volumes.

  19. Damage detection in concrete precast slabs: a quick assessment through modal tests

    Directory of Open Access Journals (Sweden)

    Leal Pimentel Roberto

    2015-01-01

    Full Text Available The use of modal tests for detecting damage in reinforced concrete precast slabs is evaluated. A set of eight slabs were tested, each belonging to flats constructed for residential use. Two groups of slabs were identified and, in each group, both cracked and uncracked slabs were found. This made it possible to compare the responses of the slabs when subjected to modal tests. The tests were carried out employing an instrumented hammer and heel drops as excitation sources. Responses were measured using an accelerometer. The lowest natural frequencies of the slabs could be identified and after filtering the results, plots indicating the variation of the lowest natural frequency versus the number of cycles of free decay were obtained for each slab. Such a plot is of more general use than the value of the natural frequency by itself, as it does not depend on slab configuration. It was observed that the cracked slabs presented a similar pattern of variation of the natural frequencies throughout the decay, being distinctive from the pattern observed for their uncracked counterparts. This provided evidence that a quick assessment of the structural condition of such slabs through the use of the tests were feasible.

  20. HDTS 2017.1 Testing and Verification Document

    Energy Technology Data Exchange (ETDEWEB)

    Whiteside, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-12-01

    This report is a continuation of the series of Hunter Dose Tracking System (HDTS) Quality Assurance documents including (Foley and Powell, 2010; Dixon, 2012; Whiteside, 2017b). In this report we have created a suite of automated test cases and a system to analyze the results of those tests as well as documented the methodology to ensure the field system performs within specifications. The software test cases cover all of the functions and interactions of functions that are practical to test. With the developed framework, if software defects are discovered, it will be easy to create one or more test cases to reproduce the defect and ensure that code changes correct the defect.

  1. Real-world comparison of two molecular methods for detection of respiratory viruses

    Directory of Open Access Journals (Sweden)

    Miller E Kathryn

    2011-06-01

    Full Text Available Abstract Background Molecular polymerase chain reaction (PCR based assays are increasingly used to diagnose viral respiratory infections and conduct epidemiology studies. Molecular assays have generally been evaluated by comparing them to conventional direct fluorescent antibody (DFA or viral culture techniques, with few published direct comparisons between molecular methods or between institutions. We sought to perform a real-world comparison of two molecular respiratory viral diagnostic methods between two experienced respiratory virus research laboratories. Methods We tested nasal and throat swab specimens obtained from 225 infants with respiratory illness for 11 common respiratory viruses using both a multiplex assay (Respiratory MultiCode-PLx Assay [RMA] and individual real-time RT-PCR (RT-rtPCR. Results Both assays detected viruses in more than 70% of specimens, but there was discordance. The RMA assay detected significantly more human metapneumovirus (HMPV and respiratory syncytial virus (RSV, while RT-rtPCR detected significantly more influenza A. We speculated that primer differences accounted for these discrepancies and redesigned the primers and probes for influenza A in the RMA assay, and for HMPV and RSV in the RT-rtPCR assay. The tests were then repeated and again compared. The new primers led to improved detection of HMPV and RSV by RT-rtPCR assay, but the RMA assay remained similar in terms of influenza detection. Conclusions Given the absence of a gold standard, clinical and research laboratories should regularly correlate the results of molecular assays with other PCR based assays, other laboratories, and with standard virologic methods to ensure consistency and accuracy.

  2. Structural design and analysis of test mass module for DECIGO Pathfinder

    International Nuclear Information System (INIS)

    Wakabayashi, Y; Ejiri, Y; Suzuki, R; Sugamoto, A; Obuchi, Y; Okada, N; Torii, Y; Ueda, A; Kawamura, S; Araya, A; Ando, M; Sato, S

    2010-01-01

    Deci-hertz Interferometer Gravitational-Wave Observatory: DECIGO is a project aimed at future detection of deci-hertz gravitational waves in space. DECIGO Pathfinder: DPF is a precursor mission to test the key technologies with one spacecraft. Our work in this article was to examine the strength of the DPF test mass module to ensure that it is sufficiently robust for launch with a launch vehicle. We designed the test mass module, and examined the structural strength of this model by structural analysis, Quasi-static acceleration analysis and Modal analysis using FEA (Finite Element Analysis). We found that the results of each analysis fulfilled all requirements. We are confident that the DPF test mass module will withstand Quasi-static acceleration or coupling with vibration of launch vehicle during launch, if the design matches the current design. For more detail, further analysis including Response analysis and Thermal analysis are recommended. In addition, it will be necessary to lighten the model in the next step.

  3. Parametric Roll Resonance Detection using Phase Correlation and Log-likelihood Testing Techniques

    DEFF Research Database (Denmark)

    Galeazzi, Roberto; Blanke, Mogens; Poulsen, Niels Kjølstad

    2009-01-01

    generation warning system the purpose of which is to provide the master with an onboard system able to trigger an alarm when parametric roll is likely to happen within the immediate future. A detection scheme is introduced, which is able to issue a warning within five roll periods after a resonant motion......Real-time detection of parametric roll is still an open issue that is gathering an increasing attention. A first generation warning systems, based on guidelines and polar diagrams, showed their potential to face issues like long-term prediction and risk assessment. This paper presents a second...... started. After having determined statistical properties of the signals at hand, a detector based on the generalised log-likelihood ratio test (GLRT) is designed to look for variation in signal power. The ability of the detector to trigger alarms when parametric roll is going to onset is evaluated on two...

  4. Sensitive technique for detecting outer defect on tube with remote field eddy current testing

    International Nuclear Information System (INIS)

    Kobayashi, Noriyasu; Nagai, Satoshi; Ochiai, Makoto; Jimbo, Noboru; Komai, Masafumi

    2008-01-01

    In the remote field eddy current testing, we proposed the method of enhancing the magnetic flux density in the vicinity of an exciter coil by controlling the magnetic flux direction for increasing the sensitivity of detecting outer defects on a tube and used the flux guide made of a magnetic material for the method. The optimum structural shape of the flux guide was designed by the magnetic field analysis. On the experiment with the application of the flux guide, the magnetic flux density increased by 59% and the artificial defect detection signal became clear. We confirmed the proposed method was effective in a high sensitivity. (author)

  5. Technical Education as a Tool for Ensuring Sustainable Development: A Case of India

    Science.gov (United States)

    Sharma, Gagan Deep; Uppal, Raminder Singh; Mahendru, Mandeep

    2016-01-01

    This paper notes that education needs to essentially lead to sustainable development serving two-fold purpose--eradicating the problems of unemployment and poverty; and ensuring equitable distribution of wealth while ensuring the right understanding leading to a peaceful, prosperous and developed world. In its current state, technical education…

  6. Evaluation of serological tests for detecting tick-borne encephalitis virus (TBEV) antibodies in animals.

    Science.gov (United States)

    Klaus, Christine; Beer, Martin; Saier, Regine; Schubert, Harald; Bischoff, Sabine; Süss, Jochen

    2011-01-01

    Tick-borne encephalitis (TBE) in animals is not well understood yet. TBE virus (TBEV) serology in several host species could be valuable for epidemiological analyses in the field as well as for the detection of clinical cases. However, performance and suitability of the available test systems are not well assessed. Therefore, we evaluated two commercial TBEV-ELISA kits in a pilot study and compared them for their suitability in veterinary applications. For this purpose, we tested 163 field collected goat sera and evaluated the results by serum neutralization test (SNT) as "gold standard". Twenty-eight SNT positive sera (17.2%) were detected. The best suited ELISA kit was used for determination of a species-specific cutoff for horses, cattle, sheep, goats, pigs, mice, dogs, rabbits and monkeys with defined sera from animals without known or with improbable contact to TBEV. The level of non-specific ELISA results does not only differ between animal species but may also be influenced by the age of the tested animals. The number of sera which tested false positive by ELISA was higher in older than in young sheep. In order to obtain defined polyclonal sera as references, two dogs, cattle, goats, sheep, rabbits and pigs each, as well as one horse and 90 mice were immunized four times with a commercially available TBEV vaccine. In conclusion, our results demonstrated that commercial TBEV-ELISA kits are suitable for application in veterinary medicine for both, verification of clinical TBE cases and epidemiological screening. However, positive ELISA results should be verified by SNT. Only a very low number of false negative ELISA-results were found.

  7. A combination test for detection of gene-environment interaction in cohort studies.

    Science.gov (United States)

    Coombes, Brandon; Basu, Saonli; McGue, Matt

    2017-07-01

    Identifying gene-environment (G-E) interactions can contribute to a better understanding of disease etiology, which may help researchers develop disease prevention strategies and interventions. One big criticism of studying G-E interaction is the lack of power due to sample size. Studies often restrict the interaction search to the top few hundred hits from a genome-wide association study or focus on potential candidate genes. In this paper, we test interactions between a candidate gene and an environmental factor to improve power by analyzing multiple variants within a gene. We extend recently developed score statistic based genetic association testing approaches to the G-E interaction testing problem. We also propose tests for interaction using gene-based summary measures that pool variants together. Although it has recently been shown that these summary measures can be biased and may lead to inflated type I error, we show that under several realistic scenarios, we can still provide valid tests of interaction. These tests use significantly less degrees of freedom and thus can have much higher power to detect interaction. Additionally, we demonstrate that the iSeq-aSum-min test, which combines a gene-based summary measure test, iSeq-aSum-G, and an interaction-based summary measure test, iSeq-aSum-I, provides a powerful alternative to test G-E interaction. We demonstrate the performance of these approaches using simulation studies and illustrate their performance to study interaction between the SNPs in several candidate genes and family climate environment on alcohol consumption using the Minnesota Center for Twin and Family Research dataset. © 2017 WILEY PERIODICALS, INC.

  8. Problems in ensuring normal actuation of pneumatic drilling machines during their manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Vasilev, V

    1982-01-01

    The problems of ensuring normal actuation and reliable operation of pneumatic drilling machines during their manufacturing are examined. The modes of operation are cited with which the normal actuation must be tested. Oscillograms are used to examine the characteristic cases of completion of machines with the impossibility of actuation during operation for one cycle or with an interruption in the mode, along with methods for eliminating these deficiencies. The effect on the actuation process of factors such as the type of rock being drilled, the change in the position of the machine, the axial force, the design of the air distribution device and the impact mechanism, the relationship between the surface areas of the distribution device and the travel of the distributor, the choking of the power and so on is studied. Different methods for completing design are analyzed.

  9. A New Generalizable Test for Detection of Mutations Affecting Tn10 Transposition

    OpenAIRE

    Huisman, Olivier; Kleckner, Nancy

    1987-01-01

    We describe here a new rapid screen that allows easy detection of transposon or host mutations that affect Tn10 transposition in Escherichia coli. This test involves a new Tn10 derivative called the "mini-lacZ-kanR fusion hopper" or mini-Tn10-LK for short. This element does not direct expression of β-galactosidase when present at its original starting location on a suitably engineered plasmid or phage genome because it lacks appropriate transcription and translation start signals. However, t...

  10. Utility of the ELF Test for Detecting Steatohepatitis in Morbid Obese Patients with Suspicion of Nonalcoholic Fatty Liver Disease.

    Science.gov (United States)

    López, Iria Cebreiros; Aroca, Florentina Guzmán; Bernal, Maria Dolores Frutos; Mompeán, Juan Antonio Luján; Bernal, Águeda Bas; Martínez, Antonio Miguel Hernández; Barba, Enrique Martínez; Velasco, Jose Antonio Noguera; Paricio, Pascual Parilla

    2017-09-01

    Morbid obese patients have a high rate of nonalcoholic fatty liver disease (NAFLD) and nonalcoholic steatohepatitis (NASH). NASH is related to the progression and poor evolution of chronic hepatopathy in NAFLD, so that its detection makes it possible to identify the subjects who are most at risk in order to prioritize treatment. The ELF test (Enhanced Liver Fibrosis test; Siemens Diagnostics, NY, USA) has been assessed for its capacity to detect fibrosis in patients with NAFLD, but its capacity for diagnosing NASH has not been checked. Our objective is to determine the utility of the ELF test for detecting NASH in morbid obese patients with suspected NAFLD. ELF values were determined in a cohort of obese patients who underwent bariatric surgery with suspected NAFLD. Liver biopsy was used as the reference standard. The values of ELF were significantly higher in patients with NASH (p = 0.002) and in those who presented with metabolic syndrome (p = 0.047). An ELF cut-off point of 8.72 allows the detection of patients with NASH with a sensitivity of 71.4% and a specificity of 74.1% (AUC = 0.742, p = 0.002). The ELF test is efficient for the identification of obese patients with NAFLD and early signs of steatohepatitis and fibrosis.

  11. Utility of the ceftazidime-imipenem antagonism test (CIAT to detect and confirm the presence of inducible AmpC beta-lactamases among enterobacteriaceae

    Directory of Open Access Journals (Sweden)

    Vlademir Vicente Cantarelli

    Full Text Available Detection of AmpC beta-lactamase production by enterobacteria has been problematic. Contrary to ESBLs, no specific guidelines are available for detection and confirmation of AmpC production by clinical relevant microorganisms. Moreover, some bacterial species may produce inducible AmpC beta-lactamases that can be easily overlooked by routine susceptibility tests. We reported here a new test based on the strong inducible effect of imipenem on AmpC genes and the consequent antagonism with ceftazidime. This test is very simple and proved to be helpful in detecting AmpC-inducible enzymes among several species of clinical isolates.

  12. Anthropomorphic Test Drive (ATD) Certification Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The ATD Certification Laboratory consists of several test fixtures to ensure ATDs are functioning correctly and within specifications prior to use in any OP testing....

  13. Structural Damage Detection Using Changes in Natural Frequencies: Theory and Applications

    Science.gov (United States)

    He, K.; Zhu, W. D.

    2011-07-01

    A vibration-based method that uses changes in natural frequencies of a structure to detect damage has advantages over conventional nondestructive tests in detecting various types of damage, including loosening of bolted joints, using minimum measurement data. Two major challenges associated with applications of the vibration-based damage detection method to engineering structures are addressed: accurate modeling of structures and the development of a robust inverse algorithm to detect damage, which are defined as the forward and inverse problems, respectively. To resolve the forward problem, new physics-based finite element modeling techniques are developed for fillets in thin-walled beams and for bolted joints, so that complex structures can be accurately modeled with a reasonable model size. To resolve the inverse problem, a logistical function transformation is introduced to convert the constrained optimization problem to an unconstrained one, and a robust iterative algorithm using a trust-region method, called the Levenberg-Marquardt method, is developed to accurately detect the locations and extent of damage. The new methodology can ensure global convergence of the iterative algorithm in solving under-determined system equations and deal with damage detection problems with relatively large modeling error and measurement noise. The vibration-based damage detection method is applied to various structures including lightning masts, a space frame structure and one of its components, and a pipeline. The exact locations and extent of damage can be detected in the numerical simulation where there is no modeling error and measurement noise. The locations and extent of damage can be successfully detected in experimental damage detection.

  14. Structural Damage Detection Using Changes in Natural Frequencies: Theory and Applications

    International Nuclear Information System (INIS)

    He, K; Zhu, W D

    2011-01-01

    A vibration-based method that uses changes in natural frequencies of a structure to detect damage has advantages over conventional nondestructive tests in detecting various types of damage, including loosening of bolted joints, using minimum measurement data. Two major challenges associated with applications of the vibration-based damage detection method to engineering structures are addressed: accurate modeling of structures and the development of a robust inverse algorithm to detect damage, which are defined as the forward and inverse problems, respectively. To resolve the forward problem, new physics-based finite element modeling techniques are developed for fillets in thin-walled beams and for bolted joints, so that complex structures can be accurately modeled with a reasonable model size. To resolve the inverse problem, a logistical function transformation is introduced to convert the constrained optimization problem to an unconstrained one, and a robust iterative algorithm using a trust-region method, called the Levenberg-Marquardt method, is developed to accurately detect the locations and extent of damage. The new methodology can ensure global convergence of the iterative algorithm in solving under-determined system equations and deal with damage detection problems with relatively large modeling error and measurement noise. The vibration-based damage detection method is applied to various structures including lightning masts, a space frame structure and one of its components, and a pipeline. The exact locations and extent of damage can be detected in the numerical simulation where there is no modeling error and measurement noise. The locations and extent of damage can be successfully detected in experimental damage detection.

  15. Quantitative assessment of hyperspectral imaging in detection of plasmonic nanoparticles: a modified contrast-detail analysis approach

    Science.gov (United States)

    Wang, Jianting; Chen, Yu; Pfefer, T. Joshua

    2016-03-01

    Hyperspectral reflectance imaging (HRI) is an emerging imaging modality being applied for clinical indications such as tissue oximetry, and cancer detection based on endogenous biological constituents including plasmonic nanoparticles. However, there is currently a lack of standardized test methods for objective, quantitative evaluation of HRI system performance. Contrast-detail analysis (CDA) is a phantom-based test method commonly used to evaluate medical imaging devices (e.g., mammography systems) in terms of their lower detection limit. We investigated a modified CDA (mCDA) method to quantify the detectability of gold nanoparticles by HRI systems. Silicone-based turbid phantoms containing micro-fluidic channels were developed for the mCDA tests. Polydimethylsiloxane (PDMS) phantom materials were doped with chromophores and scatterers to achieve biologically relevant optical properties (OPs). Molds were used to produce cylindrical channels of diameters 0.3 to 1.65 mm and depths of 0.2 mm inside the phantoms. Channels were filled with a mixture of hemoglobin and concentrations of gold nanorods (GNR) and measured with our HRI system. The contrast of GNRs was solved with a spectral unmixing algorithm from the reflectance spectra. The lowest detectable concentration was determined as a function of inclusion size and depth and plotted as modified contrast detail curve (mCDC). mCDCs were used to compare the detectabilities of the HRI system with different data processing algorithms. It is demonstrated that our mCDA test method involving turbid microchannel phantoms can help to elucidate the combined performance of imaging devices and plasmonic nanoparticle contrast agents. This approach may be useful for performing clinical trial standardization and device re-calibration, thus ensuring quality control and clinical performance.

  16. Acceptance test report, 241-SY-101 Flexible Receiver System, Phase 3 testing

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1995-01-01

    This document summarizes the results of the phase 3 acceptance test of the 241-SY-101 Flexible Receiver System (FRS). The purpose of this acceptance test is to verify the sealing integrity of the FRS to ensure that the release of waste and aerosols will be minimized during the removal of the test mixer pump from Tank 241-SY-101. The FRS is one of six major components of the Equipment Removal System, which has been designed to retrieve, transport, and store the mixer pump. This acceptance test was performed at the 306E Facility in the 300 area from January 10, 1995 to January 17, 1995. The Phase 3 test consisted of two parts. Part one was a water leak test of the seal between the blast shield and mock load distribution frame (LDF) to ensure that significant contamination of the pump pit and waste interaction with the aluminum impact-limiting material under the LDF are prevented during the pump removal operation. The second part of this acceptance test was an air leak test of the assembled flexible receiver system. The purpose of this test was to verify that the release of hazardous aerosols will be minimized if the tank dome pressure becomes slightly positive during the decontamination of the mixer pump

  17. 9 CFR 113.2 - Testing aids.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Testing aids. 113.2 Section 113.2... Testing aids. To better ensure consistent and reproducible test results when Standard Requirement tests... Agriculture, may provide testing aids, when available, to licensees, permittees, and applicants for licenses...

  18. Development of photo stimulated luminescence technique for detecting irradiated food

    International Nuclear Information System (INIS)

    Ros Anita Ahmad Ramli; Ahmad Zainuri Mohd Dzomir; Zainon Othman; Wan Saffiey Wan Abdullah

    2012-01-01

    The exposure of food to ionizing radiation is being progressively used in many countries to inactivate food pathogens, to eradicate pests and to extend shelf-life of food. To ensure free consumer choice, irradiated food will be labeled. The availability of a reliable method to detect irradiated food is important to enforce legal controls on labeling requirements, ensure proper distribution and increase consumer confidence. This paper reports on the preliminary application of photo stimulated luminescence technique (PSL) as a potential method to detect irradiated food and perhaps be used for monitoring irradiated food on sale locally in the near future. Thus this study will be beneficial and relevant for application of food irradiation towards improving food safety and security in Malaysia. (author)

  19. Arm exercise-thallium imaging testing for the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Balady, G.J.; Weiner, D.A.; Rothendler, J.A.; Ryan, T.J.

    1987-01-01

    Patients with lower limb impairment are often unable to undergo a standard bicycle or treadmill test for the evaluation of coronary artery disease. To establish an alternative method of testing, 50 subjects (aged 56 +/- 10 years) performed arm ergometry testing in conjunction with myocardial thallium scintigraphy. All underwent coronary angiography; significant coronary artery disease (greater than or equal to 70% stenosis) in at least one vessel was present in 41 (82%) of the 50 patients. Thallium scintigraphy was found to have an 83% sensitivity and 78% specificity for detecting coronary disease, compared with a sensitivity and specificity of 54% (p less than 0.01) and 67% (p = NS), respectively, for exercise electrocardiography. In the subgroup of 23 patients who had no prior myocardial infarction or left bundle branch block and were not taking digitalis, thallium scintigraphy had a sensitivity of 80% versus 50% for exercise electrocardiography. Scintigraphy yielded a sensitivity of 84, 74 and 90% for one, two and three vessel disease, respectively. Noninvasive arm ergometry exercise-thallium imaging testing appears to be reliable and useful and should be considered in the evaluation of coronary artery disease in patients with lower limb impairment

  20. A Mobile Outdoor Augmented Reality Method Combining Deep Learning Object Detection and Spatial Relationships for Geovisualization.

    Science.gov (United States)

    Rao, Jinmeng; Qiao, Yanjun; Ren, Fu; Wang, Junxing; Du, Qingyun

    2017-08-24

    The purpose of this study was to develop a robust, fast and markerless mobile augmented reality method for registration, geovisualization and interaction in uncontrolled outdoor environments. We propose a lightweight deep-learning-based object detection approach for mobile or embedded devices; the vision-based detection results of this approach are combined with spatial relationships by means of the host device's built-in Global Positioning System receiver, Inertial Measurement Unit and magnetometer. Virtual objects generated based on geospatial information are precisely registered in the real world, and an interaction method based on touch gestures is implemented. The entire method is independent of the network to ensure robustness to poor signal conditions. A prototype system was developed and tested on the Wuhan University campus to evaluate the method and validate its results. The findings demonstrate that our method achieves a high detection accuracy, stable geovisualization results and interaction.