WorldWideScience

Sample records for test collection tc

  1. GASIFICATION TEST RUN TC06

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services, Inc.

    2003-08-01

    This report discusses test campaign TC06 of the Kellogg Brown & Root, Inc. (KBR) Transport Reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using a particulate control device (PCD). The Transport Reactor was operated as a pressurized gasifier during TC06. Test run TC06 was started on July 4, 2001, and completed on September 24, 2001, with an interruption in service between July 25, 2001, and August 19, 2001, due to a filter element failure in the PCD caused by abnormal operating conditions while tuning the main air compressor. The reactor temperature was varied between 1,725 and 1,825 F at pressures from 190 to 230 psig. In TC06, 1,214 hours of solid circulation and 1,025 hours of coal feed were attained with 797 hours of coal feed after the filter element failure. Both reactor and PCD operations were stable during the test run with a stable baseline pressure drop. Due to its length and stability, the TC06 test run provided valuable data necessary to analyze long-term reactor operations and to identify necessary modifications to improve equipment and process performance as well as progressing the goal of many thousands of hours of filter element exposure.

  2. Presentation of test cases TC-2A, TC-2B, TC-2C, TC-2D - Twodimensional, incompressible, wall flows with separation

    DEFF Research Database (Denmark)

    Scheel Larsen, Poul

    1988-01-01

    The four test cases comprise the backfacing step at high Re-number (TC-2A) and low Re-number (TC-2B), a low Re-number boundary layer flow past a thin obstacle, fence-on-wall (TC-2C), and a high Re-number developed channel flow past a squareobstacle (TC-2D). Geometry, test conditions and available...

  3. Power Systems Development Facility Gasification Test Campaign TC24

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services

    2008-03-30

    In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF), located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results of TC24, the first test campaign using a bituminous coal as the feedstock in the modified Transport Gasifier configuration. TC24 was conducted from February 16, 2008, through March 19, 2008. The PSDF gasification process operated for about 230 hours in air-blown gasification mode with about 225 tons of Utah bituminous coal feed. Operational challenges in gasifier operation were related to particle agglomeration, a large percentage of oversize coal particles, low overall gasifier solids collection efficiency, and refractory degradation in the gasifier solids collection unit. The carbon conversion and syngas heating values varied widely, with low values obtained during periods of low gasifier operating temperature. Despite the operating difficulties, several periods of steady state operation were achieved, which provided useful data for future testing. TC24 operation afforded the opportunity for testing of various types of technologies, including dry coal feeding with a developmental feeder, the Pressure Decoupled Advanced Coal (PDAC) feeder; evaluating a new hot gas filter element media configuration; and enhancing syngas cleanup with water-gas shift catalysts. During TC24, the PSDF site was also made available for testing of the National Energy Technology Laboratory's fuel cell module and Media Process Technology's hydrogen selective membrane.

  4. Power Systems Development Facility Gasification Test Run TC07

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services

    2002-04-05

    This report discusses Test Campaign TC07 of the Kellogg Brown & Root, Inc. (KBR) Transport Reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using a particulate control device (PCD). The Transport Reactor was operated as a pressurized gasifier during TC07. Prior to TC07, the Transport Reactor was modified to allow operations as an oxygen-blown gasifier. Test Run TC07 was started on December 11, 2001, and the sand circulation tests (TC07A) were completed on December 14, 2001. The coal-feed tests (TC07B-D) were started on January 17, 2002 and completed on April 5, 2002. Due to operational difficulties with the reactor, the unit was taken offline several times. The reactor temperature was varied between 1,700 and 1,780 F at pressures from 200 to 240 psig. In TC07, 679 hours of solid circulation and 442 hours of coal feed, 398 hours with PRB coal and 44 hours with coal from the Calumet mine, and 33 hours of coke breeze feed were attained. Reactor operations were problematic due to instrumentation problems in the LMZ resulting in much higher than desired operating temperatures in the reactor. Both reactor and PCD operations were stable and the modifications to the lower part of the gasifier performed well while testing the gasifier with PRB coal feed.

  5. Power Systems Development Facility Gasification Test Campaign TC25

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services

    2008-12-01

    In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF), located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results of TC25, the second test campaign using a high moisture lignite coal from the Red Hills mine in Mississippi as the feedstock in the modified Transport Gasifier configuration. TC25 was conducted from July 4, 2008, through August 12, 2008. During TC25, the PSDF gasification process operated for 742 hours in air-blown gasification mode. Operation with the Mississippi lignite was significantly improved in TC25 compared to the previous test (TC22) with this fuel due to the addition of a fluid bed coal dryer. The new dryer was installed to dry coals with very high moisture contents for reliable coal feeding. The TC25 test campaign demonstrated steady operation with high carbon conversion and optimized performance of the coal handling and gasifier systems. Operation during TC25 provided the opportunity for further testing of instrumentation enhancements, hot gas filter materials, and advanced syngas cleanup technologies. The PSDF site was also made available for testing of the National Energy Technology Laboratory's fuel cell module and Media Process Technology's hydrogen selective membrane with syngas from the Transport Gasifier.

  6. 99m Tc-labeled heparin test in orthopaedic surgery

    International Nuclear Information System (INIS)

    Bouvier, J.F.; Lafon, J.C.; Colin, M.; Chatelut, J.; Beaubatie, F.

    1983-01-01

    99m Tc-labeled heparin test was performed for early detection of phlebitis or pulmonary embolism after orthopaedic prothesis. Heparinic treatment and surgery per se were demonstrated to have no effect on the results. If this test demonstrates a statistical difference for pathologic patients, it is of greater value to consider ratio between rates before and after intervention [fr

  7. IEC-TC88WG8 testing of rotor blades

    Energy Technology Data Exchange (ETDEWEB)

    Delft, D R.V. van [Delft Univ. of Technology, STEVIN Lab., Delft (Netherlands)

    1996-09-01

    In 1994 the TC88 of IEC installed a working group (WG8) to draft a guideline on blade testing. This paper gives a description of the task of the working group. Furthermore it gives a report of the progress of the work and summarizes the possible contents of the working group document on blade testing. (au)

  8. Tc-99 Adsorption on Selected Activated Carbons - Batch Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Wellman, Dawn M.; Golovich, Elizabeth C.; Cordova, Elsa A.; Smith, Ronald M.

    2010-12-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently developing a 200-West Area groundwater pump-and-treat system as the remedial action selected under the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision for Operable Unit (OU) 200-ZP-1. This report documents the results of treatability tests Pacific Northwest National Laboratory researchers conducted to quantify the ability of selected activated carbon products (or carbons) to adsorb technetium-99 (Tc-99) from 200-West Area groundwater. The Tc-99 adsorption performance of seven activated carbons (J177601 Calgon Fitrasorb 400, J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, J177612 Norit GAC830, J177613 Norit GAC830, and J177617 Nucon LW1230) were evaluated using water from well 299-W19-36. Four of the best performing carbons (J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, and J177613 Norit GAC830) were selected for batch isotherm testing. The batch isotherm tests on four of the selected carbons indicated that under lower nitrate concentration conditions (382 mg/L), Kd values ranged from 6,000 to 20,000 mL/g. In comparison. Under higher nitrate (750 mg/L) conditions, there was a measureable decrease in Tc-99 adsorption with Kd values ranging from 3,000 to 7,000 mL/g. The adsorption data fit both the Langmuir and the Freundlich equations. Supplemental tests were conducted using the two carbons that demonstrated the highest adsorption capacity to resolve the issue of the best fit isotherm. These tests indicated that Langmuir isotherms provided the best fit for Tc-99 adsorption under low nitrate concentration conditions. At the design basis concentration of Tc 0.865 µg/L(14,700 pCi/L), the predicted Kd values from using Langmuir isotherm constants were 5,980 mL/g and 6,870 mL/g for for the two carbons. These Kd values did not meet the target Kd value of 9,000 mL/g. Tests

  9. 99m Tc-MDP deposition in testes

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Carvalho, A.C.M. de

    A case of 99m Tc-MDP deposition in the testes of a patient who was submmited to therapeutic orquiectomy for prostatic adenocarcinoma six years ago, during bone scintigraphy, is reported. A brief review of the pertinent literature has been made with discussion of the possible mechanism justifying the finding. (Author) [pt

  10. The determination of 99Tc by ICP-MS in samples collected near nuclear installations

    International Nuclear Information System (INIS)

    Ihsanullah; East, B.W.

    1991-01-01

    99 Tc occurs naturally in the earth's crust primarily from spontaneous fission of 238 U and slow neutron-induced fission of 235 U. 99 Tc is also produced from nuclear detonation tests, nuclear fuel processing plants and nuclear power stations. By comparison to other sources, the contribution to 99 Tc from natural sources and use of 99m Tc in medicine is considered to be negligible. Releases of 99 Tc from the nuclear fuel cycle include reactor operation, nuclear fuel reprocessing, UF 6 conversion, uranium enrichment, U fuel fabrication, high-level waste solidification, low and high-level waste disposal; however the main contribution to the release of 99 Tc is the process of uranium enrichment. Various environmental samples from the Irish Sea and from Chernobyl have been analysed for 99 Tc by newly developed procedures using the inductively coupled plasma mass spectrometry technique. (author)

  11. Power Systems Development Facility Gasification Test Run TC09

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services

    2002-09-30

    This report discusses Test Campaign TC09 of the Kellogg Brown & Root, Inc. (KBR) Transport Gasifier train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Gasifier is an advanced circulating fluidized-bed gasifier designed to operate as either a combustor or a gasifier in air- or oxygen-blown mode of operation using a particulate control device (PCD). The Transport Gasifier was operated as a pressurized gasifier during TC09 in air- and oxygen-blown modes. Test Run TC09 was started on September 3, 2002, and completed on September 26, 2002. Both gasifier and PCD operations were stable during the test run, with a stable baseline pressure drop. The oxygen feed supply system worked well and the transition from air to oxygen was smooth. The gasifier temperature varied between 1,725 and 1,825 F at pressures from 125 to 270 psig. The gasifier operates at lower pressure during oxygen-blown mode due to the supply pressure of the oxygen system. In TC09, 414 hours of solid circulation and over 300 hours of coal feed were attained with almost 80 hours of pure oxygen feed.

  12. Sparse matrix test collections

    Energy Technology Data Exchange (ETDEWEB)

    Duff, I.

    1996-12-31

    This workshop will discuss plans for coordinating and developing sets of test matrices for the comparison and testing of sparse linear algebra software. We will talk of plans for the next release (Release 2) of the Harwell-Boeing Collection and recent work on improving the accessibility of this Collection and others through the World Wide Web. There will only be three talks of about 15 to 20 minutes followed by a discussion from the floor.

  13. Power Systems Development Facility Gasification Test Campaing TC18

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services

    2005-08-31

    In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR Transport Gasifier, a hot gas particulate control device (PCD), advanced syngas cleanup systems, and high pressure solids handling systems. This report details Test Campaign TC18 of the PSDF gasification process. Test campaign TC18 began on June 23, 2005, and ended on August 22, 2005, with the gasifier train accumulating 1,342 hours of operation using Powder River Basin (PRB) subbituminous coal. Some of the testing conducted included commissioning of a new recycle syngas compressor for gasifier aeration, evaluation of PCD filter elements and failsafes, testing of gas cleanup technologies, and further evaluation of solids handling equipment. At the conclusion of TC18, the PSDF gasification process had been operated for more than 7,750 hours.

  14. Power Systems Development Facility Gasification Test Run TC08

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services

    2002-06-30

    This report discusses Test Campaign TC08 of the Kellogg Brown & Root, Inc. (KBR) Transport Gasifier train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Gasifier is an advanced circulating fluidized-bed gasifier designed to operate as either a combustor or a gasifier in air- or oxygen-blown mode using a particulate control device (PCD). The Transport Gasifier was operated as a pressurized gasifier in air- and oxygen-blown modes during TC08. Test Run TC08 was started on June 9, 2002 and completed on June 29. Both gasifier and PCD operations were stable during the test run with a stable baseline pressure drop. The oxygen feed supply system worked well and the transition from air to oxygen blown was smooth. The gasifier temperature was varied between 1,710 and 1,770 F at pressures from 125 to 240 psig. The gasifier operates at lower pressure during oxygen-blown mode due to the supply pressure of the oxygen system. In TC08, 476 hours of solid circulation and 364 hours of coal feed were attained with 153 hours of pure oxygen feed. The gasifier and PCD operations were stable in both enriched air and 100 percent oxygen blown modes. The oxygen concentration was slowly increased during the first transition to full oxygen-blown operations. Subsequent transitions from air to oxygen blown could be completed in less than 15 minutes. Oxygen-blown operations produced the highest synthesis gas heating value to date, with a projected synthesis gas heating value averaging 175 Btu/scf. Carbon conversions averaged 93 percent, slightly lower than carbon conversions achieved during air-blown gasification.

  15. Power Systems Development Facility Gasification Test Run TC11

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services

    2003-04-30

    This report discusses Test Campaign TC11 of the Kellogg Brown & Root, Inc. (KBR) Transport Gasifier train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Gasifier is an advanced circulating fluidized-bed gasifier designed to operate as either a combustor or a gasifier in air- or oxygen-blown mode of operation using a particulate control device (PCD). Test run TC11 began on April 7, 2003, with startup of the main air compressor and the lighting of the gasifier start-up burner. The Transport Gasifier operated until April 18, 2003, when a gasifier upset forced the termination of the test run. Over the course of the entire test run, gasifier temperatures varied between 1,650 and 1,800 F at pressures from 160 to 200 psig during air-blown operations and around 135 psig during enriched-air operations. Due to a restriction in the oxygen-fed lower mixing zone (LMZ), the majority of the test run featured air-blown operations.

  16. Participation in CEN TC 335 TC343 Chemical Test Methods. Final report; Deelname CEN TC 335 TC343 Chemical Testmethods. Eindrapportage

    Energy Technology Data Exchange (ETDEWEB)

    Bakker, F.P. [ECN Engineering en Services, Petten (Netherlands)

    2006-12-15

    An overview is given of the work that has been done on the standardization of methods for the characterization of biofuels and solid recovered fuels (SRF). For biofuels a complete set of prestandards is available, conversion of pre-standards to standards is in good progress. The development of a standard biocarbon content method based on the {sup 14}C isotope measurement is in good progress. This standard could be an important tool for carbon dioxide trading purposes. CEN is the European Commission for Standardization, TC 335 is the Technical Committee 335 on Solid Biofuels, and TC 343 is the Technical Committee on Solid Recovered Fuels. [Dutch] In de periode september 2005 tot december 2006 zijn Europese standaarden voor de karakterisering van biobrandstoffen beschikbaar gekomen. Voor een aantal parameters is nader onderzoek vereist en deels gaande. Dankzij de ervaring die in Nederland is opgedaan met Nationale Technische Afspraken (NTA's) voor vaste biobrandstoffen heeft onze bijdrage aan de Europese normering de invoering daarvan zeker bespoedigd. De 14C groendeel bepaling begint terrein te winnen en zal in de nabije toekomst ook bij verdere implementatie van het Kyoto protocol een rol gaan spelen. CEN is de European Commission for Standardization, TC 335 is de Technical Committee 335 over Solid Biofuels, en TC 343 is de Technical Committee over Solid Recovered Fuels.

  17. TC-13 Mod 0 and Mod 2 Steam Catapult Test Site

    Data.gov (United States)

    Federal Laboratory Consortium — Located on 11,000 feet of test runway, the TC-13 Mod 0 and Mod 2 Steam Catapult Test Site has in-ground catapults identical to those aboard carriers. This test site...

  18. Tc and Re Behavior in Borosilicate Waste Glass Vapor Hydration Tests

    International Nuclear Information System (INIS)

    McKeown, David A.; Buechele, Andrew C.; Pegg, Ian L.; Lukens, Wayne W.; Shuh, David K.

    2007-01-01

    Technetium (Tc), found in some nuclear wastes, is of particular concern with regard to long-term storage, because of its long-lived radioactivity and high mobility in the environment. Tc and rhenium (Re), commonly used as a non-radioactive surrogate for Tc, were studied to assess their behavior in borosilicate glass under hydrothermal conditions in the Vapor Hydration Test (VHT). X-ray absorption spectroscopy (XAS) and scanning electron microscopy (SEM) measurements were made on the original Tc- and Re-containing glasses and their corresponding VHT samples, and show different behavior for Tc and Re under VHT conditions. XAS indicates that, despite starting with different Tc(IV) and Tc(VII) distributions in each glass, the VHT samples have 100% Tc(IV)O 6 environments. SEM shows complete alteration of the original glass, Tc enrichment near the sample surface, and Tc depletion in the center. Perrhenate (Re(VII)O 4 - ) is dominant in both Re-containing samples before and after the VHT, where Re is depleted near the VHT sample surface and more concentrated toward the center. (authors)

  19. Basic and clinical studies on hepatobiliary function test with sup(99m)Tc-PI

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Shigemoto, Hirosada; Ito, Yasuhiko; Muranaka, Akira; Ohtsuka, Nobuaki

    1979-01-01

    In these basic and clinical studies, the usefulness of sup(99m)Tc-pyridoxilideneisoleucine, a new hepatobiliary agent, was evaluated for a hepatobiliary function test in comparison with sup(99m)Tc-N-[N-(2,6 dimethylphenyl)carbamoylmethyl] iminodiacetic acid (HIDA) and 131 I-rose bengal (RB). The experiments were performed with 2.5 - 5 kg rabbits. Hepatic uptake and the excretion of sup(99m)Tc-pyridoxylidene isoleucine (PI) were earlier than those of 131 I-RB. However, biliary excretions of sup(99m)Tc-PI and sup(99m)Tc-HIDA were less than that of 131 I-RB, because urinary excretions of sup(99m)Tc-labeled compounds were greater. During the first 2.5 - 5 min, sup(99m)Tc-labeled agents had lower blood levels than 131 I-RB. At 6 days after the choledochal ligation, no hepatic uptake of sup(99m)Tc-PI was noted, although 131 I-RB concentrated to the liver. Blood retention of sup(99m)Tc-PI might not always reflect hepatobiliary function, especially in the hyperbilirubinemia. On the other hand, hepatograms from a region of interest corresponding to the liver varied with changes in the serum bilirubin level, although no hepatic uptake was detected in the complete obstructive jaundice and severe parenchymal liver disease being over 7 mg/dl in the serum bilirubin level. (author)

  20. Cyclotron produced Tc-99m: testing compatibility with established kits

    Czech Academy of Sciences Publication Activity Database

    Lebeda, Ondřej; Ráliš, Jan; Hradilek, Pavel; Hanč, Petr; van Lier, E. J.; Zyuzin, A.; Moša, M.

    2013-01-01

    Roč. 40, 2 Supplement (2013), S424-S425 ISSN 1619-7070. [Annual Congress of the European Association of Nuclear Medicine (EANM). 19.10.2013-23.10.2013, Lyon] Institutional support: RVO:61389005 Keywords : cyclotron U-120M * Tc-99m * 100Mo Subject RIV: BG - Nuclear, Atomic and Molecular Physics , Colliders

  1. 78 FR 40824 - Proposed Collection; Comment Request for Form 8038-TC

    Science.gov (United States)

    2013-07-08

    ... 8038-TC AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... Form 8038-TC, Information Return for Tax Credit Bonds. DATES: Written comments should be received on or...-TC. Abstract: Form 8038-TC will be used by issuers of qualified tax- exempt credit bonds, including...

  2. 75 FR 5855 - Proposed Collection; Comment Request for Form 8038-TC

    Science.gov (United States)

    2010-02-04

    ... 8038-TC AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... comments concerning Form 8038-TC, Information Return for Tax Credit Bonds. DATES: Written comments should...: Form 8038-TC. Abstract: Form 8038-TC will be used by issuers of qualified tax- exempt credit bonds...

  3. Dose calibrator linearity test: {sup 99m}Tc versus {sup 18}F radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, Jose; Coura-Filho, George Barberio; Garcez, Alexandre Teles, E-mail: willegaignon@hotmail.com [Instituto do Cancer do Estado de Sao Paulo Octavio Frias de Oliveira (ICESP), Sao Paulo, SP (Brazil); Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Fac. de Medicina; Alves, Carlos Eduardo Gonzalez Ribeiro; Cardona, Marissa Anabel Rivera; Gutterres, Ricardo Fraga [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2015-01-15

    Objective: the present study was aimed at evaluating the viability of replacing {sup 18}F with {sup 99m}Tc in dose calibrator linearity testing. Materials and methods: the test was performed with sources of {sup 99m}Tc (62 GBq) and {sup 18}F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical {sup 99m}Tc and {sup 18}F sources activities were calculated and subsequently compared. Results: mean deviations between experimental and theoretical {sup 99m}Tc and {sup 18}F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the {sup 99m}Tc source as measured with the equipment precalibrated to measure {sup 99m}Tc and {sup 18}F was 3.42 (± 0.06), and for the {sup 18}F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: the results of the linearity test using {sup 99m}Tc were compatible with those obtained with the {sup 18}F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in {sup 18}F acquisition suggest {sup 99m}Tc as the element of choice to perform dose calibrator linearity tests in centers that use {sup 18}F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. (author)

  4. Testing the radiochemical purity of a radiopharmaceutical: study of 99mTc-Tetrofosmin (Myoview)

    International Nuclear Information System (INIS)

    Moati, F.; Quartarone, C.; Jourdain, J.R.; Rizzo, N.; Dumont, A.; De Beco, V.; Ait Ben Ali, S.; Lours, S.; Piketty, M.L.; Izembart, M.; Goudou, C.; Lemercier, V.; Schlageter, M.H.; Moretti, J.L.; Progent, A.

    1997-01-01

    The goal of this study is to optimize the testing method of radiochemical purity (RCP) of 99m Tc-Tetrofosmin proposed by the Amersham Company: thin-layer chromatography (TLC); ITLC-SG support, migration on 15 Cm; acetone-dichloromethane mobile phase, (35/65, v/v), This technique allows separating the reduced-Tc (Rf = 0), the TcO 4 - (Rf = 1), and in intermediary position (0.2 99m Tc-Tetrofosmin. The results of RCP depend on working conditions, particularly, on the volume of deposit (10 to 20 μl, expected). If the deposited is too small, the 99m Tc-Tetrofosmin does not migrate. With a volume of 20 μl, the separation is weak and the peak width is un-resolvable. The results obtained correspond to the following operational conditions: migration on 8 cm; deposit of 8 to 10 μl; no drying. In these conditions the peak of 99m Tc-Tetrofosmin is well singled out: migration Rf of 0.375 to 0.625. These results have been obtained by the analysis of radio-chromatographic peak. Every strip has been cut cm by cm and the activity was measured by a gamma counter. Repeatability of the method on a series of 8 tests is good: average RCP 93.22%, mean value = 93.24%. The reproducibility was realized by measuring directly by the activity-meter the activity corresponding to 3 identifiable peaks: Reduced Tc (Rf 4 - (Rf 99m Tc-Tetrofosmin (0.25 < Rf < 0.75). On the 21 effectuated tests the inter-test RCP reproducibility was good: average value = 95.24%, CV = 2.07%, mean value 95.3%). In conclusion, the miniaturization improves the separation by Myoview (0.25 < Rf < 0.75), diminishes the migration time by a factor 4 and lowers the reactive cost of testing by 50%

  5. Behavior of 99Tc in doped-glass/basalt hydrothermal interaction tests

    International Nuclear Information System (INIS)

    Coles, D.G.; Apted, M.J.

    1984-01-01

    The release of polyvalent radionuclides from a nuclear waste repository located in basalt may be sensitively related to the redox potential (Eh) imposed by the basalt. A series of tests are reported here, evaluating the effect of basalt on the concentrations of 99 Tc released into solution from a borosilicate glass waste form. Crushed PNL 76-68 glass, doped with 0.7 mg 99 Tc/g glass, was reacted with reference basalt groundwater under oxic hydrothermal conditions in a sampling autoclave, both alone and in the presence of crushed basalt. The steady state fluid concentrations of 99 Tc and various table species were determined from samples obtained at the test conditions of 200 0 C, 30 MPa, and a initial solution to solid mass ratio of 10 for both tests. In the glass + groundwater test, the 99 Tc concentration rose rapidly to about 50 mg/L after only 200 hr of run time and remained at a value between 50 and 60 mg/L throughout the duration of the test. For the basalt + glass + groundwater test, the 99 Tc concentration rose to an initial value of about 2.5 mg/L. At about 700 hr, the 99 Tc concentration began to drop rapidly until a value near the analytical detection limit (approximately 0.005 mg/L) was reached after a test duration of 1400 hr. It is concluded that the presence of basalt in these hydrothermal experiments reduces the concentration of 99 Tc in solution by nearly four orders of magnitude, probably by control of solution Eh and subsequent precipitation of a solid containing a reduced form of technetium. Reaction mechanisms are discussed that can account for these observations. 17 references, 1 figure

  6. Evaluation of separate renal function by means of 99mTc-aprotinin uptake test

    International Nuclear Information System (INIS)

    Aprile, C.; Saponaro, R.; Villa, G.; Carena, M.; Chiari, G.; Salvadeo, A.; Lunghi, F.; Piazza, V.

    1986-01-01

    The possibility that relative kidney uptake of technetium-99m aprotinin (TcA) might be indicative of separate renal function was investigated in 89 patients who underwent both effective renal plasma flow (ERPFs) and glomerular filtration rate (GFR) determination. A reference group consisted of 27 healthy volunteers, studied only with TcA. The correlation with ERPFs (r = .73) was similar to that previously reported and confirmed. The correlation with GFR (r = .68) was better if a subgroup of renal units with TcA uptake lower than 16% (lower normal limit) was considered. Most likely, glomerular filtration is a limiting factor of the tubular uptake of TcA, and when GFR is reduced, both parameters decrease in the same manner, while if GFR is normal the two parameters are relatively independent. The correlation between TcA and GFR in 32 children was very similar to that found in adults. TcA uptake test seems to be a useful indicator of separate renal function, providing morphological information at, the same time

  7. Testing the radiochemical purity of radiopharmaceuticals: application to 99mTc-HMPAO

    International Nuclear Information System (INIS)

    Ait Ben Ali, S.; Darsin, D.; Rizzo, N.; Lours, S.; De Beco, V.; Dumont, A.; Goudou-Sinha, C.; Izembart, M.; Jourdain, J.R.; Lemercier, V.; Linsker, S.; Moati, F.; Piketty, M.L.; Schlageter, M.H.; Moretti, J.L.

    1997-01-01

    The low stability of 99m Tc-HMPAO imposes to carry out the quality testing within the 15 minutes following the preparation. This study has the aim of comparing different methods of radiochemical purity determination (RP) of this radiopharmaceutical in order to validate a fast, reproducible, feasible technique, capable of separating the primary lipophilic 99m Tc-HMPAO (I) of impurities: hydrophilic secondary complex (II), TcO 4 - , reduced and halyards Tc. The reference technique associating two thin-layer chromatographies (TLC), 'C1' and 'C2', has been compared with a TLC 'W' technique and with liquid-liquid extraction 'E' technique: C1 - stationary phase, ITLC Silica gel/mobile phase, Butanone-2; C2 - stationary phase, ITLC Silica gel/mobile phase, 0.9% NaCl; W - stationary phase, Papier Whatman n o 1/mobile phase, Ether; E - extraction with ethyls acetate /0.9% NaCl (1/1 v/v). The 'C1' chromatography allows isolating the reduced Tc and the complex II, the 'C2' chromatography does the same with TcO 4 - but it requires too long techniques (20 min.). The 'W' and 'E' techniques are rapid, reproducible and allow to separate the complex I from the other impurities without discrimination. However, as their results depend upon the deposited quantity of sampling, an optimization and standardization of the techniques are necessary. A forth technique by chromatography on Sep-Pak column is to be evaluated

  8. CONSTOR registered V/TC drop tests. Pre-test analysis by finite element method

    International Nuclear Information System (INIS)

    Voelzer, W.; Koenig, S.; Klein, K.; Tso, C.F.; Owen, S.; Monk, C.

    2004-01-01

    The CONSTOR registered family of steel-concrete-steel sandwich cask designs have been developed to fulfil both the internationally valid IAEA criteria for transportation and the requirements for long-term intermediate storage in the US and various European countries. A comprehensive drop testing programme using a full-scale prototype test cask (CONSTOR registered V/TC) has been developed as part of the application for a transport license in both Germany and the US. The drop tests using the full-scale cask will be performed by BAM at test facilities in Horstwalde. The tests will include five different 9m drops onto flat unyielding targets and seven different 1m drops onto a punch. The first drop test, a 9m side drop, will be performed during PATRAM 2004. The other drop tests will take place during the following year. The development of the cask design and the formulation of the drop test programme has been supported by an extensive series of finite element analyses. The objectives of the finite element analyses were; to provide an intermediate step in demonstrating the performance of the CONSTOR registered in fulfilling the requirements of 10 CFR 71 and the IAEA transport regulations. To justify the selection of drop tests. To predict the performance of V/TC during the drop tests. To estimate the strain and acceleration time histories at measuring points on the test cask and to aid in the setting up of the test instrumentation. To develop an analysis model that can be used in future safety analyses for transport and storage license applications and which can confidently be used to demonstrate the performance of the package. This paper presents an overview of the analyses performed, including a summary of all the different drop orientations that were considered. The major assumptions employed during the analyses are also discussed, as are the specifics of the modelling techniques that were employed. At the end of the paper, the key results obtained from the analyses

  9. Comparison of peritoneal equilibration test with 99mTc-DTPA excretion in the assessment of peritoneal permeability

    International Nuclear Information System (INIS)

    Das, B.K.; Senthilnathan, M.S.; Pradhan, P.K.; Nagabhushan, S.; Jeloka, T.K.; Sharma, R.K.

    2004-01-01

    Assessment of peritoneal permeability is necessary for successful management of end-stage renal disease (ESRD) patients by continuous ambulatory peritoneal dialysis (CAPD). The objective of this study was to develop an alternative method of assessing the peritoneal permeability and to compare this method with the conventional method, the peritoneal equilibrium test, first described by Twardowski in 1987. Twenty patients undergoing regular CAPD were included in this study. Before starting the peritoneal dialysis, 370 MBq (10 mCi) technetium-99m diethylene triamine penta-acetic acid ( 99m Tc-DTPA) was injected intravenously. A standard dose of the same quantity was kept and used later for calculations. At the end of 4 h, a dialysate fluid sample (1 ml) was collected and the total dialysis effluent fluid volume was measured. Excretion of 99m Tc-DTPA into the dialysate fluid as a percentage of the injected dose was calculated. Simultaneously, standard peritoneal equilibrium test values were recorded for comparison. Peritoneal excretion of 99m Tc-DTPA ranged from 8% to 25% of the injected dose, depending on the peritoneal membrane permeability. When the results were compared with the conventional method, a good correlation (r=0.79) was found. This innovative radionuclide technique is a simple and convenient method to assess the peritoneal membrane permeability and can be used as an alternative to the peritoneal equilibrium test, which is very cumbersome and associated with many limitations. (orig.)

  10. Quality control and testing of 99 sup (m) Tc-macroaggregated albumin

    International Nuclear Information System (INIS)

    Darte, L.; Persson, B.R.R.

    1975-06-01

    33 sup(m)Tc-labelled macroaggregated albumin particles prepared from a commercial 'kit' have been tested in detail. With the introduction of the method of gel chromatography column scanning it became possible to make fast and simple quantitative measurements of the radiochemical purity. This was found to be the only reliable method for quantitative determination of non-aggregated sup(99m)Tc-labelled albumin. The measuring results of the kit in question have shown a labelling efficiency of about 97-99 %. In addition to a few percent of sup(99m)Tc-pertechnetate less than 0.5 % of disturbing radioactivity was found. The labelling was stable for at least 5-6 h. About 80 % of the particles are in the size-range of 10-80 μm. A rough estimation of the number of particles in the solution resulted in 0.5 x 10 6 per mg of MAA. The dynamic studies of the lung uptake and the elimination of sup(99m)Tc-MAA in man resulted in a biological half-time in the lungs of about 1-2 h. The radiation absorbed dose to the lungs per mCi administrered sup(99m)Tc-MAA was estimated to 0.1 rad. Less than 1 % of the radioactivity was accumulated in liver, spleen or kidneys during the first 25 minutes after injection. (author)

  11. Performance testing of PZC generators for 99mTc production

    International Nuclear Information System (INIS)

    Bulos, Adelina DM.

    2006-01-01

    The report briefly describes the performance testing done on seven batches of polyzirconium column (PZC) material. PZC is a ready-to-use high molybdenum-capacity column material for adsorbing reactor-produced 99 Mo. The PZC material was manufactured by Kaken Co in Japan and was sent to PNRI for performance evaluation. Fission molybdenum was eluted from a commercial 99 Mo - 99m Tc generator. The eluted 99 Mo in a molybdenum carrier solution was adsorbed on PZC through a series of procedures. The mixture was decanted to a 90 x 12 mm glass column. 99m Tc was eluted with saline solution. The parameters measured were Tc 99m yield, %molybdenum adsorption and desorption, elution profile and radiochemical purity. (author)

  12. Comparison of peritoneal equilibration test(PET) with Tc99m-DTPA excretion in the assessment of peritoneal permeability

    International Nuclear Information System (INIS)

    Das, B.K.; Senthilnathan, M.S.; Pradhan, P.K.; Jeloka, T.K.; Nagabhushan, S.; Sharma, R.K.

    2002-01-01

    Aim: Assessment of peritoneal permeability is necessary for successful management of End Stage Renal Disease (ESRD) patients by Continuous Ambulatory Peritoneal Dialysis (CAPD). Twardowski in 1987 described for the first time a method know as Peritoneal Equilibration Test (PET ) to determine peritoneal membrane characteristics. However, this test is not only cumbersome but is associated with several limitations. The objective of this study was to develop an alternative method of assessing the peritoneal permeability and compare this method with the conventional PET. Method: Twenty patients under going regular CAPD were included in this study. Before starting the peritoneal dialysis 370 MBq (10 mCi) 99mTc-DTPA was injected intravenously in the same standard precondition as for PET evaluation. A standard dose of same quantity was kept and used later for calculations. At the end of four hours a dialysate fluid sample (1 ml) was collected and the total dialysis effluent fluid volume was measured. Excretion of 99mTc-DTPA into the dialysate fluid as percentage of injected dose was calculated. Simultaneously standard PET values were recorded for comparison. Results: Peritoneal excretion of 99mTc-DTPA ranged from 8 % to 16 % of the injected dose depending upon the peritoneal membrane permeability. Depending upon the DTPA excretion the patients were divided into 4 groups: High Transporter (15% and above; High Average (12 to 15 %); Low Average (10 to 12%); Low Average (10% and less). When the results were compared with the conventional PET values, a good correlation (r=0.79) could be found. Conclusion: Determining the excretion of 99mTc-DTPA in the dialysate fluid after 4 hrs as percentage of the injected dose is a simple and convenient method to assess the peritoneal membrane permeability and can be used as an alternative technique to conventional PET which is very cumbersome and associated with many limitations

  13. Assessment of RELAP5/MOD3 Version 7 based on the BETHSY Test 6.2 TC

    International Nuclear Information System (INIS)

    Choi, C.J.; Roth, P.A.; Schultz, R.R.

    1992-01-01

    This document provides a discussion of the BETHSY test 6.2 TC which was conducted to investigate thermal hydraulic phenomena during a 5% cold leg SBLOCA and to provide high quality data for advanced thermal-hydraulic code assessment. BETHSY test 6.2 TC was analyzed using RELAP5/MOD3 version 7o

  14. Hepatobiliary scintigraphy and function test with sup(99m)Tc-N-pyridoxyl-5-methyltryptophan (sup(99m)Tc-PMT)

    International Nuclear Information System (INIS)

    Sugimura, Kazuro; Nishiyama, Shoji; Narabayashi, Isamu

    1985-01-01

    The authors studied the effectiveness of sup(99m)Tc-N-pyridoxyl-5-methyltryptophan (sup(99m)Tc-PMT) for dynamic imaging and function on 40 patients with various hepatobiliary diseases and on healthy individuals. In healthy subjects, sup(99m)Tc-PMT is rapidly removed from the blood by the parenchymal cells of the liver and is excreted through the biliary system. The imaging of the liver, bile ducts, gallbladder and intestines with sup(99m)Tc-PMT was satisfactory. There was no renal visualization. In the case of serial images of healthy individuals, the gallbladder, intrahepatic bile duct and small intestine were visualized after 18.8 +- 7.2, 8.8 +- 1.4, and 16.7 +- 6.3 min, respectively; the mean peak time on the hepatogram was 8.0 +- 5.3 min. The bile ducts of patients with liver disorders were visualized later than those of healthy individuals. Particularly in the case of severe liver parenchymal diseases, the appearance time for the bile duct was significantly delayed. However, the delays in appearance time did not correlate well with low scores on the liver function test. At 70 min after the intravenous administration of sup(99m)Tc-PMT, 2.5 +- 1.5 % of the injected dose was excreted into the urine of the healthy individuals. The urinary excretion of sup(99m)Tc-PMT by the patients with hepatobiliary diseases showed no increase, and it was not entirely related to the results of the serum function tests. However, a larger amount of sup(99m)Tc-PMT was retained in the blood of the patients with hepatobiliary diseases. The blood retention values at 20 min after injection into those with liver cirrhosis and hepatoma were significantly delayed. (author)

  15. Experimental and clinical studies on hepatobiliary scintigraphy and function test with sup(99m)Tc-E-HIDA

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Otsuka, Nobuaki; Terashima, Hideaki; Yokobayashi, Tsuneo; Kaji, Tatsumi

    1980-01-01

    In experimental and clinical studies, the usefulness of sup(99m)Tc-E-HIDA has been evaluated for dynamic imaging and function test. Biological distribution of sup(99m)Tc-E-HIDA in rabbits at 1 hour after the intravenous administration indicated that activity was 62% of the injected dose in the gallbladder and intestine, 2% in the liver, and 9% in the kidneys and urine. Hepatic uptake and excretion of sup(99m)Tc-E-HIDA were discussed in comparison with those of sup(99m)Tc-p-butyl-IDA, sup(99m)Tc-HIDA, sup(99m)Tc-PI and 123 I-RB. Radiochemical purity was ascertained by thin layer chromatography in saline. Labelling was nearly 100%, namely no unreacted pertechnetate was detected. In clinical study, the imaging of liver, bile ducts, gallbladder and intestine was satisfactory with sup(99m)Tc-E-HIDA. There was no or faint renal visualization in cases with hepatic uptake on the hepatogram. Quantitative analysis of blood retention, blood clearance and hepatogram with sup(99m)Tc-E-HIDA reflected excretory liver function in various hepatobiliary disorders. We concluded that sup(99m)Tc-E-HIDA has a lower urinary excretion and seems more effective than the other sup(99m)Tc-labels, such as sup(99m)Tc-HIDA and sup(99m)Tc-PI, at higher bilirubin levels. However, when the level of the bilirubin in blood rises above 7.4 mg/dl, no hepatic uptake of sup(99m)Tc-E-HIDA was obtained with greater renal excretion. (author)

  16. Comparative evaluation of 131I-hippuran and sup(99m)Tc-DTPA for renal function test

    International Nuclear Information System (INIS)

    Kempi, V.; Persson, R.B.R.; Svensson, L.

    1975-07-01

    131 I-labelled Hippuran and sup(99m)Tc-labelled DTPA have been compared as substances used for renal function tests. The radiation absorbed dose for 131 I-Hippuran and sup(99m)Tc-DTPA to different organs of an adult standard man is given i a table, showing considerably lower doses for sup(99m)Tc-DTPA. Good agreement was found between the renographic curves obtained with 131 I-Hippuran and sup(99m)Tc-DTPA compared to 131 I-Hippuran excellent scintiphotos of the kidney and also of the upper urinary ways were obtained with sup(99m)Tc-DTPA. With sup(99m)Tc-DTPA, repeated examinations make it possible to follow the development of a disease without great radiation risk to the patient (K.K.)

  17. Tc-99m DTPA renal function tests and diuretic renogram in the dilated upper urinary tract

    Energy Technology Data Exchange (ETDEWEB)

    Sakagami, Yoshinari; Yamaguchi, Osamu; Suzuki, Takayuki; Kameoka, Hiroshi; Shiraiwa, Yasuo; Suzuki, Akira (Fukushima Medical Coll. (Japan))

    1992-09-01

    The authors studied patients with dilated upper urinary tracts (16 patients) using radioisotopic split renal function tests and diuretic renogram with [sup 99]mTc-diethylenetriaminepentaacetic acid (Tc-99m DTPA). The etiology was ureteropelvic function stenosis, 11; primary megaureter, 3; ureteral stenosis, 1; and aberrant vessel, 1. Response to diuresis was classified into 3 groups: i.e., obstructive pattern, non-obstructive pattern and partial obstructive pattern. In the non-obstructive group, split renal function was good, and thus an operation was not indicated. In the obstructive group, split renal function was significantly decreased and these patients underwent surgery. In the partial obstructive group, if function of the obstructed kidney was approximately the same as that of the non-obstructed side, then surgery was considered unnecessary. (author).

  18. Tc-99m DTPA renal function tests and diuretic renogram in the dilated upper urinary tract

    International Nuclear Information System (INIS)

    Sakagami, Yoshinari; Yamaguchi, Osamu; Suzuki, Takayuki; Kameoka, Hiroshi; Shiraiwa, Yasuo; Suzuki, Akira

    1992-01-01

    The authors studied patients with dilated upper urinary tracts (16 patients) using radioisotopic split renal function tests and diuretic renogram with 99 mTc-diethylenetriaminepentaacetic acid (Tc-99m DTPA). The etiology was ureteropelvic function stenosis, 11; primary megaureter, 3; ureteral stenosis, 1; and aberrant vessel, 1. Response to diuresis was classified into 3 groups: i.e., obstructive pattern, non-obstructive pattern and partial obstructive pattern. In the non-obstructive group, split renal function was good, and thus an operation was not indicated. In the obstructive group, split renal function was significantly decreased and these patients underwent surgery. In the partial obstructive group, if function of the obstructed kidney was approximately the same as that of the non-obstructed side, then surgery was considered unnecessary. (author)

  19. Performance tests on column materials for {sup 99}Mo-{sup 99m}Tc generator

    Energy Technology Data Exchange (ETDEWEB)

    Sombrito, E Z; Bulos, A D; Tangonan, M C [Chemistry Research Section, Atomic Research Div., Philippine Nuclear Research Inst., Quezon (Philippines)

    1998-10-01

    To meet the need of producing a {sup 99}Mo-{sup 99m}Tc generator, based on low specific activity reactor-produced {sup 99}Mo, different procedures for preparing zirconium molybdate gels were tested. Performance tests were done on molybdate gel columns prepared using the procedures developed by Vietnam and China, and recently, on a polyzirconium compound (PZC) prepared in Japan. The conditions for the batch drying of a large volume of the gel material were studied as well as the conditions in preparing a column to concentrate technetium-99m. The performance of PZC sample as column material for the generator was also evaluated. (author)

  20. Microwave testing of high-Tc based direct current to a single flux quantum converter

    DEFF Research Database (Denmark)

    Kaplunenko, V. K.; Fischer, Gerd Michael; Ivanov, Z. G.

    1994-01-01

    Design, simulation, and experimental investigations of a direct current to a single flux quantum converter loaded with a Josephson transmission line and driven by an external 70 GHz microwave oscillator are reported. The test circuit includes nine YBaCuO Josephson junctions aligned on the grain...... boundary of a 0°–32° asymmetric Y-ZrO2 bicrystal substrate. The performance of such converters is important for the development of the fast Josephson samplers required for testing of high-Tc rapid single flux quantum circuits in high-speed digital superconducting electronics. Journal of Applied Physics...

  1. Liver function test with 99mTc-labelled bilirubin in children

    International Nuclear Information System (INIS)

    Teichmann, B.; Kaempfer, I.; Schneider, G.

    1989-01-01

    Because of central role of bilirubin in the metabolism of liver it is well suited for liver function tests. Different parameters of hepatocellular partial function and histological findings were studied in patients suffering from functional hyperbilirubinaemia (n = 15), liver cirrhosis (n = 7) and 6 patients recovering from acute hepatitis. After intravenous injection of 99m Tc-bilirubin blood clearance and intestinal excretion in percentages of bilirubin were determined. In patients with cirrhosis the initial phase as well as the intestinal excretion of bilirubin were delayed. This liver function test is useful in the pediatric special diagnosis for investigations during the course of the illness and for assessment of therapeutic activities. (author)

  2. The PZC-based Tc-99m generator preparation and its performance test

    International Nuclear Information System (INIS)

    Liu Yishu

    2007-01-01

    This paper described the preparation of Tc-99m generator prepared with Japan distributing Mo adsorbent PZC and irradiated nature MoO 3 and its performance test. Four Tc-99m generators were prepared with different batches of PZC and reactor irradiated nature MoO 3 . The adsorption capacity of PZC to Mo is approximately 200mgMo/gPZC. The adsorption efficiency of three batches PZC is good (>90%) and that of one batch of PZC is not good enough (∼83%). The loss of fine powder (The PZC is fragile) is quite different with the different preparation process of PZC. The elution efficiency is 80-90% and has the up trend with the elution date. The Mo breakthrough can be controlled to acceptable level by connecting HZO safe column containing 1.0g HZO. All the specifications of eluted from PZC-based Tc-99m generator can meet the requirements under Sodium Pertechnetate injection in China Pharmacopoeia. (author)

  3. Homologous labelling of leukocytes with Tc 99m- dimeric ethylcysteinate (DEC): 'in vitro' and 'in vivo' tests

    International Nuclear Information System (INIS)

    Soroa, Victoria E.; Ozker, K.

    1999-01-01

    Preliminary tests have been carried out to validate the use of DEC -Tc 99m labelled leukocytes as a more stable substitute for Tc 99m-HMPAO in the diagnosis of infectious and inflammatory diseases. Although in all the patients the infectious focuses have been detected and the results are promissory, further studies with different infections /inflammations are needed to validate the procedure as an alternative routine technique

  4. Loss-of-coolant accident test series TC-1 experiment operating specifications

    International Nuclear Information System (INIS)

    Yackle, T.R.

    1979-09-01

    The purpose of this document is to specify the experiment operating procedure for the test series TC-1. The effects of externally mounted cladding thermocouples on the fuel rod thermal behavior during LOCA blowdown and reflood cycles will be investigated in the test. Potential thermocouple effects include: (a) delayed DNB, (b) momentary cladding rewets following DNB, (c) premature cladding rewet during a blowdown two-phase slug period, and (d) early cladding rewet during reflood. The two-phase slug period will be controlled by momentarily opening the hot leg valve. The slug will consist of lower plenum liquid that is sent through the flow shrouds and will be designed to quench the fuel rods at a rate that is similar to the slug experienced early in the LOFT L2-2 and L2-3 tests

  5. Performance tests on new chromatographic material for 99Mo-99mTc generators

    International Nuclear Information System (INIS)

    Sombrito, Elvira Z.; Bulos, Adelina D.M.

    2004-01-01

    Technetium-99m continues to be the main workhorse of nuclear medicine in the Philippines. Almost 13TBq of 99m Tc was imported to the country in 2002 supplied as 99m Tc- 99 Mo generators. These generators make use of fission molybdenum adsorbed onto an alumina column. Problems associated with the alumina chromatographic generators arise due to safety and economic issues that would be remedied by gel-type generators using low specific activity reactor-produced molybdenum-99 adsorbed on a high capacity gel column material. The Philippine Nuclear Research Institute (PNRI) exerted efforts in this direction by developing a gel-type column, which showed satisfactory molybdenum adsorptive capacity. Likewise, Kaken Co. in Japan in cooperation with Japan Atomic Energy Research Institute (JAERI) developed a dried form of a gel-type polyzirconium compound (PZC). It is a ready-to-use high molybdenum capacity column material for adsorbing reactor-produced molybedum-99. The performance of this material is being tested under the framework of the FNCA project on Research Reactor Utilization. Performance tests on four batches of PZC were performed using fission molybdenum eluted from a 99 Mo- 99m Tc generator. A total of 3.3 GBq 99 Mo was extracted from an alumina column of a commercial generator and mixed with carrier molybdenum solution. About 0.67 GBq was loaded into each of the 12 x 90 mm column. One batch was prepared and distributed in 1999 and tests showed very poor elution yield of 30%. Three recent batches of PZC (2002) gave elution yields of 71% (Range of 69-75). The adsorptive capacity is 99% with about 4% desorption rate. Elution volume is at 5-6 ml. Daily elution for five days gave from 1.6 to 5.5% variability. The tests were performed all at the same time and a trend of improving elution yield and consistency of daily elution yield was observed with the time of testing nearer to the sample preparation date. X-ray diffraction analysis showed an amorphous structure for

  6. Media Fill Test for validation of autologous leukocytes separation and labelling by (99m)Tc-HmPAO.

    Science.gov (United States)

    Urbano, Nicoletta; Modoni, Sergio; Schillaci, Orazio

    2013-01-01

    Manufacturing of sterile products must be carried out in order to minimize risks of microbiological contamination. White blood cells (WBC) labelled with (99m)Tc-exametazime ((99m)Tc-hexamethylpropyleneamine oxime; (99m)Tc-HMPAO) are being successfully applied in the field of infection/inflammation scintigraphy for many years. In our radiopharmacy lab, separation and labelling of autologous leukocytes with (99m)Tc-HMPAO were performed in a laminar flow cabinet not classified and placed in a controlled area, whereas (99m)Tc-HMPAO radiolabelling procedure was carried out in a hot cell with manipulator gloves. This study was conducted to validate this process using a Media Fill simulation test. The study was performed using sterile Tryptic Soy Broth (TSB) in place of active product, reproducing as closely as possible the routine aseptic production process with all the critical steps, as described in the our internal standard operative procedures (SOP). The final vials containing the media of each processed step were then incubated for 14 days and examined for the evidence of microbial growth. No evidence of turbidity was observed in all the steps assayed by the Media Fill. In the separation and labelling of autologous leukocytes with (99m)Tc-HmPAO, Media-Fill test represents a reliable tool to validate the aseptic process. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. On the reusability of open test collections

    NARCIS (Netherlands)

    Hashemi, S.H.; Clarke, C.L.A.; Dean-Hall, A.; Kamps, J.; Kiseleva, Y.

    2015-01-01

    Creating test collections for modern search tasks is increasingly more challenging due to the growing scale and dynamic nature of content, and need for richer contextualization of the statements of request. To address these issues, the TREC Contextual Suggestion Track explored an open test

  8. In vitro cytotoxicity testing of Ubiquicidin 29-41-{sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Ocampo, Ivette Z.; Okazaki, Kayo; Dias, Luis Alberto Pereira; Higa, Olga Z.; Silva, Fabiana M. da; Vieira, Daniel P., E-mail: dpvieira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Passos, Priscila; Esteves-Pedro, Natalia M., E-mail: fabiana@biosintesis.com.br [Laboratorio Biosintesis Ltda, Sao Paulo, SP (Brazil)

    2015-07-01

    The work carried out cytotoxicity tests using a radiopharmaceutical compound produced at IPEN/CNEN-SP to certify its safety through in vitro cytotoxicity tests. Since 2009, the Brazilian regulatory agency (ANVISA) requires that such tests have to be carried out following good laboratory practices (GLP) and in according to the OECD (Organisation for Economic Co-operation and Development) guidelines in order to certify its safety for medical use. Those guidelines comprises series of technical recommendations performed to assure quality of experiments. The study chose Ubiquicidin 29-41, an antimicrobial peptide used to discriminate bacterial infection foci from inflammatory sites. Amounts of UBI{sub 29-41} were conjugated or not to {sup 99m}Tc and diluted to equivalent concentrations of 10, 100 and 1000% of the maximum dose (or activity) administered in adults. Possible cytotoxic effects were evaluated in comparison to untreated controls as well as positive and negative damage controls. Both full (radioactive) radiopharmaceuticals, as their precursors (only molecules without conjugation to isotopes) showed no significant cytotoxic effect (cytotoxicity ≤ 10%). The study was conducted for the first time in the country comprising preclinical testing of this radiopharmaceutical in accordance with internationally accepted quality parameters, ensuring the safety of its use and enabling inclusion in the pharmaceutical regulatory agenda. (author)

  9. In vitro cytotoxicity testing of Ubiquicidin 29-41-99mTc

    International Nuclear Information System (INIS)

    Ocampo, Ivette Z.; Okazaki, Kayo; Dias, Luis Alberto Pereira; Higa, Olga Z.; Silva, Fabiana M. da; Vieira, Daniel P.; Passos, Priscila; Esteves-Pedro, Natalia M.

    2015-01-01

    The work carried out cytotoxicity tests using a radiopharmaceutical compound produced at IPEN/CNEN-SP to certify its safety through in vitro cytotoxicity tests. Since 2009, the Brazilian regulatory agency (ANVISA) requires that such tests have to be carried out following good laboratory practices (GLP) and in according to the OECD (Organisation for Economic Co-operation and Development) guidelines in order to certify its safety for medical use. Those guidelines comprises series of technical recommendations performed to assure quality of experiments. The study chose Ubiquicidin 29-41, an antimicrobial peptide used to discriminate bacterial infection foci from inflammatory sites. Amounts of UBI 29-41 were conjugated or not to 99m Tc and diluted to equivalent concentrations of 10, 100 and 1000% of the maximum dose (or activity) administered in adults. Possible cytotoxic effects were evaluated in comparison to untreated controls as well as positive and negative damage controls. Both full (radioactive) radiopharmaceuticals, as their precursors (only molecules without conjugation to isotopes) showed no significant cytotoxic effect (cytotoxicity ≤ 10%). The study was conducted for the first time in the country comprising preclinical testing of this radiopharmaceutical in accordance with internationally accepted quality parameters, ensuring the safety of its use and enabling inclusion in the pharmaceutical regulatory agenda. (author)

  10. Homologous labelling of leukocytes with Tc 99m- dimeric ethylcysteinate (DEC): 'in vitro' and 'in vivo' tests; Marcacion leucocitaria homologa con Tc99m-Etilcisteinato dimero (ECD): pruebas 'in vitro' e 'in vivo'

    Energy Technology Data Exchange (ETDEWEB)

    Soroa, Victoria E [Hospital de Clinicas Jose de San Martin, Buenos Aires (Argentina). Centro de Medicina Nuclear; Ozker, K [Medical Coll. of Wisconsin, Milwaukee, WI (United States). Dept. of Radiology

    1999-07-01

    Preliminary tests have been carried out to validate the use of DEC -Tc 99m labelled leukocytes as a more stable substitute for Tc 99m-HMPAO in the diagnosis of infectious and inflammatory diseases. Although in all the patients the infectious focuses have been detected and the results are promissory, further studies with different infections /inflammations are needed to validate the procedure as an alternative routine technique.

  11. Migration of 99Tc in unsaturated Chinese loess under artificial rainfall condition: an in situ test

    International Nuclear Information System (INIS)

    Liu, C.L.; Wang, X.Y.; Wang, H.F.; Li, R.J.; Tang, L.T.

    2001-01-01

    The migration of 99 Tc in unsaturated Chinese loess under artificial rainfall condition was investigated in situ. Water suckers were buried at different depths under the bottom of an experimental pit of 2 m x 2 m x 1 m (deep). Quartz containing 3 H and 99 Tc was introduced into the experimental pit to an area of 40 cm x 40 cm and the pit was backfilled to a thickness of 30 cm. An artificial rainfall of 5 mm/h was applied to the experimental pit 4 h a day for 3 months. Moisture water samples were sucked with the help of a vacuum pumping system and the activity of 3 H and 99 Tc in the samples was determined. Breakthrough curves of 3 H and 99 Tc indicated that 99 Tc was slightly retarded. The calculated average apparent distribution coefficient of 99 Tc in the medium was (1.98 ± 0.42) x 10 -2 ml/g. (orig.)

  12. Diagnostic value of 99mTc-ethambutol scintigraphy in tuberculosis: compared to microbiological and histopathological tests.

    Science.gov (United States)

    Kartamihardja, A H S; Kurniawati, Y; Gunawan, R

    2018-01-01

    Tuberculosis (TB) still remains the world's endemic infection. TB affects the lungs and any part of the body other than the lung. The diagnosis of TB has not changed much over the decades. Ethambutol is one of the first line treatments for TB. It can be labeled using 99m Tc. 99m Tc-ethambutol will be accumulated in the site of TB lesion and can be imaged using gamma camera. The aim of this study was to evaluate the diagnostic value of 99m Tc-ethambutol scintigraphy in detecting and localizing of TB. Retrospective cross-sectional study was done. Subjects were patients suspected of having TB infection. Whole body and SPECT-CT imaging at the suspected area was done 1 and 4 h after injection of 370-555 MBq 99m Tc-ethambutol. 99m Tc-ethambutol scintigraphy was analyzed visually. The results were compared with that of histopathological or microbiological tests. Statistical analysis was done to determine the sensitivity, specificity, PPV, NPV and accuracy. One hundred and sixty-eight subjects were involved in this study. There were 110 men and 58 women with mean age of 34.52 ± 11.94 years. There were concordance results in 156 (92.86%) and discordant in 12 (7.14%) subjects between 99m Tc-ethambutol scintigraphy and histopathological or microbiological result. The sensitivity, specificity, PPV, NPV and accuracy of 99m Tc-ethambutol scintigraphy in the diagnosis of pulmonary TB were 93.9, 85.7, 93.9, 85.7 and 91.4%, respectively, for extra-pulmonary TB 95.5, 77.8, 97.9, 63.6, and 85.1%, respectively, and for total tuberculosis 94.9, 83.3, 96.3, 78.1 and 92.8%, respectively. There was no side effect observed in this study. 99m Tc-ethambutol scintigraphy is a useful diagnostic imaging technique to detect and localize intra- and extra-pulmonary TB. It is safe to be performed even in pediatric patient. Consuming ethambutol less than 2 weeks did not influence the result.

  13. Advanced Presentation of BETHSY 6.2TC Test Results Calculated by RELAP5 and TRACE

    Directory of Open Access Journals (Sweden)

    Andrej Prošek

    2012-01-01

    Full Text Available Today most software applications come with a graphical user interface, including U.S. Nuclear Regulatory Commission TRAC/RELAP Advanced Computational Engine (TRACE best-estimate reactor system code. The graphical user interface is called Symbolic Nuclear Analysis Package (SNAP. The purpose of the present study was to assess the TRACE computer code and to assess the SNAP capabilities for input deck preparation and advanced presentation of the results. BETHSY 6.2 TC test was selected, which is 15.24 cm equivalent diameter horizontal cold leg break. For calculations the TRACE V5.0 Patch 1 and RELAP5/MOD3.3 Patch 4 were used. The RELAP5 legacy input deck was converted to TRACE input deck using SNAP. The RELAP5 and TRACE comparison to experimental data showed that TRACE results are as good as or better than the RELAP5 calculated results. The developed animation masks were of great help in comparison of results and investigating the calculated physical phenomena and processes.

  14. Return to normal of sup(99m)Tc-plasmin test after deep venous thrombosis and its relationship to vessel wall fibrinolysis

    Energy Technology Data Exchange (ETDEWEB)

    Edenbrandt, C.M.; Hedner, U.; Tengborn, L.; Nilsson, J.; Ohlin, P.

    1986-08-01

    Fourteen patients with deep venous thrombosis (DVT) and a positive sup(99m)Tc-plasmin test were followed up to determine how soon a negative test was obtained. Localization and extension of the thrombi were determined by phlebography. Plasminogen activator activity in vein walls and local fibrinolytic activity after venous occlusion were measured in order to find out what the prerequisites for impaired thrombolysis are. The time required to obtain a negative sup(99m)Tc-plasmin test showed considerable variation, ranging from less than 1 week to more than 6 months. The sup(99m)Tc-plasmin test had returned to normal in 64% of the patients after 6 months. No relationship was found between vessel wall fibrinolysis and time to normalization. Instead, we found an association between the time to normalization of the sup(99m)Tc-plasmin test and the size of the thrombus, according to phlebography, as well as between the time to normalization of the sup(99m)Tc-plasmin test and the extension of leg points with a positive sup(99m)Tc-plasmin test at admission. The finding of abnormal sup(99m)Tc-plasmin test results more than 6 months after acute DVT is of practical importance and warrants caution when evaluating patients with symptoms and signs suggestive of acute recurrent DVT.

  15. Collective excitations and superconductivity in reduced dimensional systems - Possible mechanism for high Tc

    International Nuclear Information System (INIS)

    Santoyo, B.M.

    1989-01-01

    The author studies in full detail a possible mechanism of superconductivity in slender electronic systems of finite cross section. This mechanism is based on the pairing interaction mediated by the multiple modes of acoustic plasmons in these structures. First, he shows that multiple non-Landau-damped acoustic plasmon modes exist for electrons in a quasi-one dimensional wire at finite temperatures. These plasmons are of two basic types. The first one is made up by the collective longitudinal oscillations of the electrons essentially of a given transverse energy level oscillating against the electrons in the neighboring transverse energy level. The modes are called Slender Acoustic Plasmons or SAP's. The other mode is the quasi-one dimensional acoustic plasmon mode in which all the electrons oscillate together in phase among themselves but out of phase against the positive ion background. He shows numerically and argues physically that even for a temperature comparable to the mode separation Δω the SAP's and the quasi-one dimensional plasmon persist. Then, based on a clear physical picture, he develops in terms of the dielectric function a theory of superconductivity capable of treating the simultaneous participation of multiple bosonic modes that mediate the pairing interaction. The effect of mode damping is then incorporated in a simple manner that is free of the encumbrance of the strong-coupling, Green's function formalism usually required for the retardation effect. Explicit formulae including such damping are derived for the critical temperature T c and the energy gap Δ 0 . With those modes and armed with such a formalism, he proceeds to investigate a possible superconducting mechanism for high T c in quasi-one dimensional single-wire and multi-wire systems

  16. Brain perfusion SPECT imaging before and during the acetazolamide test using sup 99m Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Higashi, Sotaro; Kinuya, Keiko; Tsuji, Shiro; Sumiya, Hisashi; Hisada, Kinichi; Yamashita, Junkoh (Kanazawa Univ. (Japan). School of Medicine)

    1990-05-01

    A new method using brain perfusion {sup 99m}Tc-HMPAO SPECT imaging was developed for evaluating cerebral perfusion reserve by the acetazolamide test with a short period. The first SPECT study was carried out for 13.5 min to obtain SPECT images at the resting state after 3 min postinjection of 555 MBq (15 mCi) of {sup 99m}Tc-HMPAO. At the same time as the start of the first SPECT study, 1 g of acetazolamide was intravenously injected. Immediately after the stop of the 1st SPECT study, 925 MBq (25 mCi) of {sup 99m}Tc-HMPAO from the same vial as in the first study was additionally injected. Three minutes later the second SPECT study was carried out for 10 min. After reconstruction the tomographic images in the first study were subtracted from the images in the second study to obtain those during the acetazolamide test after correction of the time differences in data acquisition between the two studies. This subtraction technique gives independent brain perfusion SPECT images before and during the acetazolamide test. Besides, the regional flow changes during the test were quantitatively analyzed. In conclusion this method seems to be practically useful for evaluating regional brain perfusion before and during drug treatments as a consecutive study with a short period of approximately 30 min. (author).

  17. Diagnosis of ischemic cerebrovascular diseases with 99mTc-HMPAO brain SPECT using upright stress test

    International Nuclear Information System (INIS)

    Chen Shaoliang; Xiu Yan; Sun Xiaoguang

    1998-01-01

    Purpose: To evaluate the value of upright brain SPECT stress test, the authors performed 99m Tc-HMPAO brain SPECT in association with measurement of blood pressure in both upright and supine positions. Methods: The authors studied 5 patients with unilateral stenosis occlusion of the internal carotid (Group A), 8 patients with orthostatic hypotension (group B) and 7 normal controls. 370 MBq 99m Tc-HMPAO was injected immediately after uprighting from a supine position. then the first SPECT scan were performed. After the first SPECT, another 555 MBq of 99m Tc-HMPAO were administered while the patients remained on original supine position. Results: Semiquantitive analysis showed that the asymmetric ratios between upright and supine positions in group A changed significantly. In group B, showed postural cerebral hypoperfusion in the bilateral frontal areas, the mean count ratio of the frontal to cerebellar area between the upright and supine positions also significantly changed. In the normal group, there were no significantly changes during the upright test. Conclusions: The upright stress test is useful for detecting not only silent cerebral hypoperfusion, but also orthostatic hypoperfusion

  18. Testing of 99mTc labelled sucralfate in induced gastric and duodenal ulcers

    International Nuclear Information System (INIS)

    Pallagi, Katalin; Janoki, Gyoezoe

    1988-01-01

    The conditions of in vitro labelling of sucralfate available in medical practice were established according to literature data including some modifications. Labelling efficiency proved to be 98.1%. The radiopharmaceutical is stable over 6 hours in vitro. 99m Tc-sucralfate accumulates in experimentally induced gastric and duodenal ulcers thus tracing the site of the ulcerous lesion. (author) 14 refs.; 3 tabs

  19. Testing the radiochemical purity of a radiopharmaceutical: study of {sup 99m}Tc-Tetrofosmin (Myoview); Controle de la purete radiochimique d`un radiopharmaceutique: etude du {sup 99m}Tc-Tetrofosmin (Myoview)

    Energy Technology Data Exchange (ETDEWEB)

    Moati, F.; Quartarone, C.; Jourdain, J.R.; Rizzo, N.; Dumont, A.; De Beco, V.; Ait Ben Ali, S.; Lours, S.; Piketty, M.L.; Izembart, M.; Goudou, C.; Lemercier, V.; Schlageter, M.H.; Moretti, J.L.; Progent, A. [Groupe de travail `Radiopharmaceutiques - Ile de France` (France)

    1997-12-31

    The goal of this study is to optimize the testing method of radiochemical purity (RCP) of {sup 99m}Tc-Tetrofosmin proposed by the Amersham Company: thin-layer chromatography (TLC); ITLC-SG support, migration on 15 Cm; acetone-dichloromethane mobile phase, (35/65, v/v), This technique allows separating the reduced-Tc (Rf = 0), the TcO{sub 4}{sup -} (Rf = 1), and in intermediary position (0.2Tc-Tetrofosmin. The results of RCP depend on working conditions, particularly, on the volume of deposit (10 to 20 {mu}l, expected). If the deposited is too small, the {sup 99m}Tc-Tetrofosmin does not migrate. With a volume of 20 {mu}l, the separation is weak and the peak width is un-resolvable. The results obtained correspond to the following operational conditions: migration on 8 cm; deposit of 8 to 10 {mu}l; no drying. In these conditions the peak of {sup 99m}Tc-Tetrofosmin is well singled out: migration Rf of 0.375 to 0.625. These results have been obtained by the analysis of radio-chromatographic peak. Every strip has been cut cm by cm and the activity was measured by a gamma counter. Repeatability of the method on a series of 8 tests is good: average RCP 93.22%, mean value = 93.24%. The reproducibility was realized by measuring directly by the activity-meter the activity corresponding to 3 identifiable peaks: Reduced Tc (Rf < 0.25), TcO{sub 4}{sup -} (Rf < 0.75), and {sup 99m}Tc-Tetrofosmin (0.25 < Rf < 0.75). On the 21 effectuated tests the inter-test RCP reproducibility was good: average value = 95.24%, CV = 2.07%, mean value 95.3%. In conclusion, the miniaturization improves the separation by Myoview (0.25 < Rf < 0.75), diminishes the migration time by a factor 4 and lowers the reactive cost of testing by 50%

  20. Dry Kit Development And Clinical Test Of 99mTc-L,L-ECD Radiopharmaceutical For Vrain Perfusion Imaging

    International Nuclear Information System (INIS)

    Kartini, Nani; Sofyan, Rohestri; Rukmini; Iswahyudi

    2000-01-01

    Technetium- 99m ethyl cysteinate dimer ( 99m Tc-L,L-ECD) has been synthesized and formulated based on ligand exchanged reaction with 99mTc-glucoheptonate. Considering the low stability of the dry kit produced, it was fairly necessary to develop the manufacture of L,L-ECD dry kit in order to obtain a more stable one that meet the requirements as brain perfusion imaging radiopharmaceutical. Experiment was done by modifying the packing of dry kit components of the previous formulation. Characteristics of 99m Tc-L,L-ECD produced from this formulation were studied by carrying out the sterility and toxicity test, then followed with clinical test to some volunteers. Evaluation of brain perfusion was done by tomography technique using gamma camera at Nuclear Medicine Installation, Hasan Sadikin Hospital. The modified formulation obtained consist of three components i.e. main ligand L,L-ECD; exchange ligand Ca-glucoheptonate and HaOH. Its stability could reach 8 months at-10 derajat C of storage. Effects of toxicity on mice did not appear. The result of clinical study shows that the radiopharmaceutical was distributed very rapidly in the blood brain circulations and retained in the brain for about one hour. The body scanning indicates that the substance was excreted in the brain for about one hour. The body scanning indicates that the substance was excreted though kidney, liver and spleen. Based on the results obtained the radiopharmaceutical could be promoted to be used for brain perfusion imaging

  1. A functional test of the salivary gland using sup(99m)Tc-pertechnetate

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke; Oshima, Motoo

    1981-01-01

    The function of the parotid glands were studied in 45 patients with parotid gland diseases, with the salivary glands affection systemic diseases, and with radiation injury of the parotid glands. As a control, the studies were done on 13 patients with no history of salivary gland disease. The method is consisted of sequential scientigraphy using a gamma scintillation camera and simultaneous recordings of the time-activity curves for the regions over the parotid glands and Stensen's orifices. The examination was commenced immediately after intravenous injection of sup(99m)Tc, and was continued up to 30 minutes. Salivation was stimulated with oral administration of tartaric acid at 20 minutes after injection. According to whether the uptake, concentration and excretion of sup(99m)Tc were diminished or increased, the time-activity curves could be grouped four different patterns. Using this method, a clinician can determine the exact stage of glandular dysfunction. (author)

  2. Relationship between 99mTc-ECD SPECT images and performance of the Wisconsin card sorting test in healthy humans

    International Nuclear Information System (INIS)

    Zhao Jinhua; Lin Xiangtong; Guan Yihui; Xu Lianqin; Zhang Guangming; Xue Fangpeng

    1998-01-01

    Purpose: To investigate the relationship between 99m Tc-ECD SPECT and performance of the Wisconsin Card Sorting Test (WCST) in normal young and aged volunteers through the semi-quantitative analysis of the baseline and cognition activated rCBF images. Methods: 18 young and 17 aged volunteers were enrolled. The education level of the two groups was matched. All subjects were healthy and CT results of all the aged volunteers were normal. Both baseline and cognition activated 99m Tc-ECD SPECT were performed on all the subjects. The cognition activated brain SPECT: The cognitive task was WCST. 1110 MBq 99m Tc-ECD was administered by intravenous bolus injection 5 minutes after the onset of the WCST. The images were reconstructed and semiquantitatively analyzed. WCST were scored through 9 items: 1) period, 2) categories, 3) total corrects, 4) conceptual level (%), 5) perseverative responses, 6) total errors, 7) perseverative errors, 8) perseverative error (%), 9) non-perseverative errors. Results: 1) Compared with the baseline, the activated rCBF values of frontal, left temporal and left parietal lobes were higher in young subjects. 2) The activated rCBF values of right frontal lobe is slightly higher than those of baseline in aged group. 3) WCST scores: the young had significantly better scores than the aged in 7 items. 4) The baseline and activated rCBF values of the frontal lobes and anterior cingule were closely related to the scores of categories, perseverative responses, total errors and non-perseverative errors. Conclusions: 1) The distribution patterns of 99m Tc-ECD are different between young and aged volunteers. 2) The performance of WCST mainly relates to frontal lobes. The mild hypoperfusion of the frontal lobe in aged group may be the cause of poor conceptual and thinking ability. 3) First found the significant correlation between anterior cingule and performance of WCST

  3. Proficiency tests for evaluation of the {sup 99}Tc{sup m} measurements in the nuclear medicine; Aplicacao de teste de proficiencia para avaliacao da medicao de {sup 99}Tc{sup m} na medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Iwahara, Akira; Tauhata, Luiz; Oliveira, Antonio Eduardo de, E-mail: iwahara@ird.gov.b, E-mail: tauhata@ird.gov.b, E-mail: aedu@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Nicoli, Ieda Gomes, E-mail: ieda@ird.gov.b [Comissao Nacional de Energia Nuclear (CNEN/DF), Brasilia, DF (Brazil). Escritorio de Brasilia; Alabarse, Frederico Gil; Xavier, Ana Maria, E-mail: falabarse@ird.gov.b, E-mail: axavier@ird.gov.b [Comissao Nacional de Energia Nuclear (ESPOA/CNEN-RS), Porto Alegre, RS (Brazil). Escritorio de Porto Alegre

    2009-07-01

    This work performs the performance evaluation of 55 Brazilian nuclear medicine services in activity measurement of radiopharmaceutical containing {sup 99}Tc{sup m}. Proficiency tests based on the acceptance criteria of the Regulation ISO/IEC Guide 43-1 and on the accuracy of the brazilian Regulation CNEN-NN-3.05 were applied in 63 results of activity measurements in radionuclide calibrators used by those services. The performance services has shown that the criteria of the ISO/IEC 43-1, nevertheless to be more restrictive, presents results very consistent with the accuracy criteria requested by the Brazilian regulation

  4. Noninvasive regional cerebral blood flow measurements at pre- and post-acetazolamide test using 99mTc-ECD

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Nakano, Seigo; Tanaka, Masaaki.

    1996-01-01

    A technique for serial noninvasive cerebral blood flow measurements at pre- and post-acetazolamide (Diamox) test was newly developed using 99m Tc-ECD without blood sampling. Baseline mean cerebral blood flow (mCBF) was measured from graphical analysis of time activity curves for brain and aortic arch obtained from radionuclide angiography by injection of 370-555 MBq 99m Tc-ECD. The first SPECT study was performed immediately after intravenous administration of 1 g of Diamox, then baseline regional cerebral blood flow (rCBF) was calculated using Lassen's correction algorithm. Immediately after the stop of the first SPECT study, additional 555-740 MBq of 99m Tc-ECD was administered, thereafter the second SPECT study was started. Post-Diamox SPECT images were obtained by subtraction of the first baseline images from the second images. Using Lassen's algorithm, post-Diamox mCBF was estimated from the baseline mCBF, the baseline mean SPECT counts, and post-Diamox mean SPECT counts corrected for administered dose and imaging time. Post-Diamox rCBF was obtained from the post-Diamox mCBF and the post-Diamox mean SPECT counts using Lassen's algorithm. Coefficient variation was shown 2.7% and 3.5%: mCBF and rCBF, respectively in test-retest results in six patients without Diamox administration. Nine demented patients without vascular disorders showed significant mCBF increase of 35.7% on the average by post-Diamox. In conclusion, this simplified method is practically useful for measuring CBF at pre- and post-Diamox test within short period of time without any blood sample. (author)

  5. Testing the radiochemical purity of radiopharmaceuticals: application to {sup 99m}Tc-HMPAO; Controle de la purete radiochimique des radiopharmaceutiques: application au {sup 99m}Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Ait Ben Ali, S.; Darsin, D.; Rizzo, N.; Lours, S.; De Beco, V.; Dumont, A.; Goudou-Sinha, C.; Izembart, M.; Jourdain, J.R.; Lemercier, V.; Linsker, S.; Moati, F.; Piketty, M.L.; Schlageter, M.H.; Moretti, J.L. [Groupe de travail `Radiopharmaceutique - Ile de France` (France)

    1997-12-31

    The low stability of {sup 99m}Tc-HMPAO imposes to carry out the quality testing within the 15 minutes following the preparation. This study has the aim of comparing different methods of radiochemical purity determination (RP) of this radiopharmaceutical in order to validate a fast, reproducible, feasible technique, capable of separating the primary lipophilic {sup 99m}Tc-HMPAO (I) of impurities: hydrophilic secondary complex (II), TcO{sub 4}{sup -}, reduced and halyards Tc. The reference technique associating two thin-layer chromatographies (TLC), `C1` and `C2`, has been compared with a TLC `W` technique and with liquid-liquid extraction `E` technique: C1 - stationary phase, ITLC Silica gel/mobile phase, Butanone-2; C2 - stationary phase, ITLC Silica gel/mobile phase, 0.9% NaCl; W - stationary phase, Papier Whatman n{sup o} 1/mobile phase, Ether; E - extraction with ethyls acetate /0.9% NaCl (1/1 v/v). The `C1` chromatography allows isolating the reduced Tc and the complex II, the `C2` chromatography does the same with TcO{sub 4}{sup -} but it requires too long techniques (20 min.). The `W` and `E` techniques are rapid, reproducible and allow to separate the complex I from the other impurities without discrimination. However, as their results depend upon the deposited quantity of sampling, an optimization and standardization of the techniques are necessary. A forth technique by chromatography on Sep-Pak column is to be evaluated

  6. Assessment of RELAP/MOD3 using BETHSY 6.2TC 6-inch cold leg side break comparative test

    International Nuclear Information System (INIS)

    Chung, Young-Jong; Jeong, Jae-Jun; Chang, Won-Pyo; Kim, Dong-Su

    1996-10-01

    This report presents the results of the RELAP5/MOD3 Version 7j assessment on BETHSY 6.2TC. BETHSY 6.2TC test corresponding to a six inch cold leg break LOCA of the Pressurizer Water Reactor(PWR). The primary objective of the test was to provide reference data of two facilities of different scales (BETHSY and LSTF facility). On the other hand, the present calculation aims at analysis of RELAP5/N4OD3 capability on the small break LOCA simulation, The results of calculation have shown that the RELAP5/MOD3 reasonably predicts occurrences as well as trends of the major phenomena such as primary pressure, timing of loop seal clearing, liquid hold up, etc. However, some disagreements also have been found in the predictions of loop seal clearing, collapsed core water level after loop seal clearing, and accumulator injection behaviors. For better understanding of discrepancies in same predictions, several sensitivity calculations have been performed as well. These include the changes of two-phase discharge coefficient at the break junction and some corrections of the interphase drag term. As result, change of a single parameter has not improved the overall predictions and it has been found that the interphase drag model has still large uncertainties

  7. Traditional Chinese version of the Mayer Salovey Caruso Emotional Intelligence Test (MSCEIT-TC): Its validation and application to schizophrenic individuals.

    Science.gov (United States)

    Mao, Wei-Chung; Chen, Li-Fen; Chi, Chia-Hsing; Lin, Ching-Hung; Kao, Yu-Chen; Hsu, Wen-Yau; Lane, Hsien-Yuan; Hsieh, Jen-Chuen

    2016-09-30

    Schizophrenia is an illness that impairs a person's social cognition. The Mayer Salovey Caruso Emotional Intelligence Test (MSCEIT) is the most well-known test used to measure emotional intelligence (EI), which is a major component of social cognition. Given the absence of EI ability-based scales adapted to Chinese speakers, we translated the MSCEIT into a Traditional Chinese version (MSCEIT-TC) and validated this scale for use in schizophrenia studies. The specific aims were to validate the MSCEIT-TC, to develop a norm for the MSCEIT-TC, and use this norm to explore the EI performance of schizophrenic individuals. We included in our study seven hundred twenty-eight healthy controls and seventy-six individuals with schizophrenia. The results suggest that the MSCEIT-TC is reliable and valid when assessing EI. The results showed good discrimination and validity when comparing the two study groups. Impairment was the greatest for two branches Understanding and Managing Emotions, which implies that the deficits of schizophrenia individuals involve ToM (theory of mind) tasks. Deficits involving the negative scale of schizophrenia was related to impaired performance when the MSCEIT-TC was used (in branch 2, 3, 4, and the area Strategic). Our findings suggest that the MSCEIT-TC can be used for emotional studies in healthy Chinese and in clinical setting for investigating schizophrenic individuals. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Enhanced99Tc retention in glass waste form using Tc(IV)-incorporated Fe minerals

    OpenAIRE

    Um, W; Luksic, SA; Wang, G; Saslow, S; Kim, DS; Schweiger, MJ; Soderquist, CZ; Bowden, ME; Lukens, WW; Kruger, AA

    2017-01-01

    © 2017 Elsevier B.V. Technetium ( 99 Tc) immobilization by doping into iron oxide mineral phases may alleviate the problems with Tc volatility during vitrification of nuclear waste. Because reduced Tc, Tc(IV), substitutes for Fe(III) in the crystal structure by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation of Fe oxide minerals, two Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were prepared and tested for Tc retention in glass melt sample...

  9. Revealed preference tests for collective household behavior

    NARCIS (Netherlands)

    Cherchye, L.J.H.; de Rock, B.; Vermeulen, F.M.P.; Verriest, E.; Molina, J.A.

    2011-01-01

    This chapter contains a state of the art of revealed preference tests for consistency of observed household behavior with Pareto efficiency. These tests are entirely nonparametric, since they do not require any assumptions regarding the parametric form of individual preferences or the intrahousehold

  10. Forest Seed Collection, Processing,and Testing

    DEFF Research Database (Denmark)

    Schmidt, Lars Holger

    2016-01-01

    This chapter pertains to the techniques of capturing the best genetic quality seeds a seed source can produce at the optimal time of high physiological maturity and maintaining these qualities throughout the handling processes, all at a minimum cost. Different collection and processing techniques...... apply to different species, seed types, situations, and purposes. Yet the collection and processing toolbox contains a number of “standard” methods for most of these groups. Records and documentation help in evaluating “best practice” for future method improvement, and it helps in linking offspring...... to seed source. Conditions are set for short- and long-term seed storage by their inert storability physiology. The potential storage life of seed may for some robust “orthodox” species be several decades, while no available storage conditions can maintain viability for sensitive “recalcitrant” seed. Seed...

  11. Round robin tests of Tc and Ic on YBa/sub 2/Cu/sub 3/O/sub x/

    International Nuclear Information System (INIS)

    Kimura, Y.; Higuchi, N.; Meguro, S.; Takahashi, K.; Uyeda, K.; Ishihara, T.; Inukai, E.; Umeda, M.

    1989-01-01

    In the author's research and development of oxide superconducting material, methods for measuring the critical properties such as critical temperature and critical current were investigated and studied by way of round robin tests. The investigation was carried out through the steps of (1) decision on the specifications of common samples and measuring methods, (2) preparation and characterization of common samples, (3) distribution of samples to ten member research organs of Super-GM, (4) experimental measurement in the respective research organs, and (5) analysis of measurement results. The measurement of critical temperature and critical current were made mainly using the 4-probe method, and partially the magnetization method. The results were found to disperse, depending on the measurement methods and definitions of Tc and lc. Data analysis with these factors clarified is important

  12. Collective Protection (COLPRO) Novel Closures Testing

    Science.gov (United States)

    2013-03-28

    properly secured to avoid incidental movement . Mixing fans must not be placed inside the TFA. e. The dissemination system must be able to maintain the...pressure in the test chamber. (1) The negative pressure ensures that any air leakage results in air movement from the chamber into the dissemination...than the dissemination compartment. This result is to be expected because random Brownian motion of the disseminated vapor molecules does not permit

  13. Delayed decrease in hemispheric cerebral blood flow during Wada test demonstrated by 99mTc-HMPAO single photon emission computer tomography

    International Nuclear Information System (INIS)

    Ryding, E.; Sjoeholm, H.; Skeidsvoll, H.; Elmqvist, D.

    1989-01-01

    We describe how brain regions with a flow (and metabolism) decrease can be visualized after an injection of short-acting barbiturate in one of the internal carotid arteries during a Wada test. An intravenous administration of 99mTc-HMPAO was used to mark the relative flow distribution. The 99mTc-HMPAO distribution in the brain was recorded three-dimensionally about 1 h later, by means of a single photon emission computer tomograph. We show that the timing of the intravenous 99mTc-HMPAO administration during the Wada test is important for the visualization of the low-flow regions. The administration of the tracer substance should be delayed at least 30 s after the first signs of the barbiturate effect. The rCBF decrease in the barbiturate-injected cerebral hemisphere was associated with a simultaneous decrease in the contralateral, pharmacologically not directly affected, cerebellar hemisphere (crossed cerebellar diaschisis). (author)

  14. Enhanced 99 Tc retention in glass waste form using Tc(IV)-incorporated Fe minerals

    Energy Technology Data Exchange (ETDEWEB)

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui; Saslow, Sarah; Kim, Dong-Sang; Schweiger, Michael J.; Soderquist, Chuck Z.; Bowden, Mark E.; Lukens, Wayne W.; Kruger, Albert A.

    2017-11-01

    Technetium (99Tc) immobilization by doping into iron oxide mineral phases may alleviate the problems with Tc volatility during vitrification of nuclear waste. Reduced Tc, Tc(IV), substitutes for Fe(III) in the crystal structure by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation of Fe oxide minerals. Two Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were prepared and tested for Tc retention in glass melt samples at temperatures between 600 – 1,000 oC. After being cooled, the solid glass specimens prepared at different temperatures were analyzed for Tc oxidation state using Tc K-edge XANES. In most samples, Tc was partially oxidized from Tc(IV) to Tc(VII) as the melt temperature increased. However, Tc retention in glass melt samples prepared using Tc-incorporated Fe minerals were moderately higher than in glass prepared using KTcO4 because of limited and delayed Tc volatilization.

  15. Operational Based Vision Assessment Automated Vision Test Collection User Guide

    Science.gov (United States)

    2017-05-15

    AFRL-SA-WP-SR-2017-0012 Operational Based Vision Assessment Automated Vision Test Collection User Guide Elizabeth Shoda, Alex...June 2015 – May 2017 4. TITLE AND SUBTITLE Operational Based Vision Assessment Automated Vision Test Collection User Guide 5a. CONTRACT NUMBER... automated vision tests , or AVT. Development of the AVT was required to support threshold-level vision testing capability needed to investigate the

  16. Generating pseudo test collections for learning to rank scientific articles

    NARCIS (Netherlands)

    Berendsen, R.; Tsagkias, M.; de Rijke, M.; Meij, E.

    2012-01-01

    Pseudo test collections are automatically generated to provide training material for learning to rank methods. We propose a method for generating pseudo test collections in the domain of digital libraries, where data is relatively sparse, but comes with rich annotations. Our intuition is that

  17. High temperature superconductivity: Concept, preparation and testing of high Tc superconductor compounds, and applications

    International Nuclear Information System (INIS)

    Harara, Wafik

    1992-06-01

    Many studies have been carried out on high temperature superconductors with transition temperature above that of the liquid nitrogen. In this scientific study the concept and the mechanism of this phenomena are discussed, in addition the examples of preparation and testing of high temperature superconductors compounds are shown. Also the most important applications in industry are explained. (author). 15 refs., 2 tabs., 18 figs

  18. Molecular imaging with {sup 99m}Tc-MIBI and molecular testing for mutations in differentiating benign from malignant follicular neoplasm: a prospective comparison

    Energy Technology Data Exchange (ETDEWEB)

    Giovanella, L.; Treglia, G.; Ceriani, L. [Oncology Institute of Southern Switzerland, Department of Nuclear Medicine and Thyroid Centre, Bellinzona (Switzerland); Campenni, A. [Policlinico Universitario, Istituto di Medicina Nucleare, Messina (Italy); Verburg, F.A. [RWTH University Hospital Aachen, Department of Nuclear Medicine, Aachen (Germany); Trimboli, P. [Oncology Institute of Southern Switzerland, Department of Nuclear Medicine and Thyroid Centre, Bellinzona (Switzerland); Ospedale Israelitico, Sezione di Endocrinologia e Diabetologia, Roma (Italy); Bongiovanni, M. [Centre Hopitalier Universitaire Vaudouise, Institut de Pathologie, Lausanne (Switzerland)

    2016-06-15

    To compare mutation analysis of cytology specimens and {sup 99m}Tc-MIBI thyroid scintigraphy for differentiating benign from malignant thyroid nodules in patients with a cytological reading of follicular neoplasm. Patients ≥18 years of age with a solitary hypofunctioning thyroid nodule (≥10 mm), normal thyrotropin and calcitonin levels, and a cytological diagnosis of follicular neoplasm were prospectively enrolled. Mutation analysis and {sup 99m}Tc-MIBI scintigraphy were performed and patients were subsequently operated on to confirm or exclude a malignant lesion. Mutations for KRAS, HRAS and NRAS and for BRAF and translocations of PAX8/PPARγ, RET/PTC1 and RET/PTC3 were investigated. Static thyroid scintigraphic images were acquired 10 and 60 min after intravenous injection of 200 MBq of {sup 99m}Tc-MIBI and visually assessed. Additionally, the MIBI washout index was calculated using a semiquantitative method. In our series, 26 % of nodules with a follicular pattern on cytology were malignant with a prevalence of follicular carcinomas. {sup 99m}Tc-MIBI scintigraphy was found to be significantly more accurate (positive likelihood ratio 4.56 for visual assessment and 12.35 for semiquantitative assessment) than mutation analysis (positive likelihood ratio 1.74). A negative {sup 99m}Tc-MIBI scan reliably excluded malignancy. In patients with a thyroid nodule cytologically diagnosed as a follicular proliferation, semiquantitative analysis of {sup 99m}Tc-MIBI scintigraphy should be the preferred method for differentiating benign from malignant nodules. It is superior to molecular testing for the presence of differentiated thyroid cancer-associated mutations in fine-needle aspiration cytology sample material. (orig.)

  19. Molecular imaging with (99m)Tc-MIBI and molecular testing for mutations in differentiating benign from malignant follicular neoplasm: a prospective comparison.

    Science.gov (United States)

    Giovanella, L; Campenni, A; Treglia, G; Verburg, F A; Trimboli, P; Ceriani, L; Bongiovanni, M

    2016-06-01

    To compare mutation analysis of cytology specimens and (99m)Tc-MIBI thyroid scintigraphy for differentiating benign from malignant thyroid nodules in patients with a cytological reading of follicular neoplasm. Patients ≥18 years of age with a solitary hypofunctioning thyroid nodule (≥10 mm), normal thyrotropin and calcitonin levels, and a cytological diagnosis of follicular neoplasm were prospectively enrolled. Mutation analysis and (99m)Tc-MIBI scintigraphy were performed and patients were subsequently operated on to confirm or exclude a malignant lesion. Mutations for KRAS, HRAS and NRAS and for BRAF and translocations of PAX8/PPARγ, RET/PTC1 and RET/PTC3 were investigated. Static thyroid scintigraphic images were acquired 10 and 60 min after intravenous injection of 200 MBq of (99m)Tc-MIBI and visually assessed. Additionally, the MIBI washout index was calculated using a semiquantitative method. In our series, 26 % of nodules with a follicular pattern on cytology were malignant with a prevalence of follicular carcinomas. (99m)Tc-MIBI scintigraphy was found to be significantly more accurate (positive likelihood ratio 4.56 for visual assessment and 12.35 for semiquantitative assessment) than mutation analysis (positive likelihood ratio 1.74). A negative (99m)Tc-MIBI scan reliably excluded malignancy. In patients with a thyroid nodule cytologically diagnosed as a follicular proliferation, semiquantitative analysis of (99m)Tc-MIBI scintigraphy should be the preferred method for differentiating benign from malignant nodules. It is superior to molecular testing for the presence of differentiated thyroid cancer-associated mutations in fine-needle aspiration cytology sample material.

  20. Stability of U(VI) and Tc(VII) Reducing Microbial Communities to Environmental Perturbation: Development and Testing of a Thermodynamic Network Model

    International Nuclear Information System (INIS)

    McKinley, James P.; Istok, Jonathan

    2005-01-01

    Previously published research from in situ field experiments at the NABIR Field Research Center have shown that cooperative metabolism of denitrifiers and Fe(III)/sulfate reducers is essential for creating subsurface conditions favorable for U(VI) and Tc(VII) bioreduction (Istok et al., 2004). The overall goal of this project is to develop and test a thermodynamic network model for predicting the effects of substrate additions and environmental perturbations on the composition and functional stability of subsurface microbial communities. The overall scientific hypothesis is that a thermodynamic analysis of the energy-yielding reactions performed by broadly defined groups of microorganisms can be used to make quantitative and testable predictions of the change in microbial community composition that will occur when a substrate is added to the subsurface or when environmental conditions change. An interactive computer program was developed to calculate the overall growth equation and free energy yield for microorganisms that grow by coupling selected combinations of electron acceptor and electron donor half-reactions. Each group performs a specific function (e.g. oxidation of acetate coupled to reduction of nitrate); collectively the groups provide a theoretical description of the entire natural microbial community. The microbial growth data are combined with an existing thermodynamic data base for associated geochemical reactions and used to simulate the coupled microbial-geochemical response of a complex natural system to substrate addition or any other environmental perturbations

  1. Developing a Test Collection for the Evaluation of Integrated Search

    DEFF Research Database (Denmark)

    Lykke, Marianne; Larsen, Birger; Lund, Haakon

    2010-01-01

    he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection c...... assessments. The test collection may be used for systems- as well as user-oriented evaluation.......he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection...... constructed for this purpose. The test collection consists of approx. 18,000 monographic records, 160,000 papers and journal articles in PDF and 275,000 abstracts with a varied set of metadata and vocabularies from the physics domain, 65 topics based on real work tasks and corresponding graded relevance...

  2. 78 FR 60287 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2013-10-01

    ... communication strategies, messages, and labels. These communications will aim to improve public understanding of... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-1164] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  3. 75 FR 51271 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2010-08-19

    ... communication strategies, messages, and labels. These communications will aim to improve public understanding of... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0420] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  4. 75 FR 39952 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2010-07-13

    ... communications will aim to improve public understanding of the risks and benefits of using medical devices and... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0344] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  5. Comparison of different methods for radiochemical purity testing of [99mTc-EDDA-HYNIC-D-Phe1,Tyr3]-Octreotide

    International Nuclear Information System (INIS)

    Guggenberg, Elisabeth von; Penz, Barbara; Kemmler, Georg; Virgolini, Irene; Decristoforo, Clemens

    2006-01-01

    [ 99m Tc-EDDA-HYNIC-D-Phe 1 ,Tyr 3 ]-octreotide ( 99m Tc-EDDA-HYNIC-TOC) is an alternative radioligand for somatostatin receptor (SSTR) scintigraphy of neuroendocrine tumours. In order to allow a rapid and accurate determination of the quality in the clinical routine the aim of this study was to evaluate different methods of radiochemical purity (RCP) testing. Three different methods of RCP testing were compared: high-performance liquid chromatograhpy (HPLC), thin layer chromatography (TLC) and minicolumn (Sep-Pak purification=SPE). HPLC was shown to be the most effective method for the quality control. The use of TLC and SPE is only recommended after sufficient practical labelling experience

  6. Comparison of different methods for radiochemical purity testing of [99mTc-EDDA-HYNIC-D-Phe1,Tyr3]-octreotide.

    Science.gov (United States)

    von Guggenberg, Elisabeth; Penz, Barbara; Kemmler, Georg; Virgolini, Irene; Decristoforo, Clemens

    2006-02-01

    [99mTc-EDDA-HYNIC-D-Phe1,Tyr3]-octreotide (99mTc-EDDA-HYNIC-TOC) is an alternative radioligand for somatostatin receptor (SSTR) scintigraphy of neuroendocrine tumours. In order to allow a rapid and accurate determination of the quality in the clinical routine the aim of this study was to evaluate different methods of radiochemical purity (RCP) testing. Three different methods of RCP testing were compared: high-performance liquid chromatography (HPLC), thin layer chromatography (TLC) and minicolumn (Sep-Pak purification = SPE). HPLC was shown to be the most effective method for the quality control. The use of TLC and SPE is only recommended after sufficient practical labelling experience.

  7. ACER Chemistry Test Item Collection (ACER CHEMTIC Year 12 Supplement).

    Science.gov (United States)

    Australian Council for Educational Research, Hawthorn.

    This publication contains 317 multiple-choice chemistry test items related to topics covered in the Victorian (Australia) Year 12 chemistry course. It allows teachers access to a range of items suitable for diagnostic and achievement purposes, supplementing the ACER Chemistry Test Item Collection--Year 12 (CHEMTIC). The topics covered are: organic…

  8. Final report on the proficiency test on the determination of total arsenic concentration in water TC Project BGD/08/018

    International Nuclear Information System (INIS)

    Shakhashiro, A.; Trinkl, A.; Rossbach, M.; Benesch, T.; Campbell, M.; Sansone, U.; Will, K.; Schorn, R.; Toervenyi, A.

    2005-02-01

    A proficiency test on the determination of arsenic in drinking water was organised within the frame of the TC project BGD/8/018 to evaluate the analytical performance of laboratories in Bangladesh. This report summarises the performance evaluation of the participating laboratories. Analytical data evaluation showed that 61% of data obtained a 'Passed' final score for both the accuracy and precision criteria applied to this exercise. (author)

  9. The Almahata Sitta Polymict Ureilite from the University of Khartoum Collection: Classification, Distribution of Clast Types in the Strewn Field, New Meteorite Types, and Implications for the Structure of Asteroid 2008 TC3

    Science.gov (United States)

    Goodrich, C. A.; Fioretti, A. M.; Zolensky, M.; Ross, Daniel K.; Shaddad, M.; Ross, D. K.; Kohl, I.; Young, E.; Kita, N.; Hiroi, T.; hide

    2018-01-01

    The Almahata Sitta (AhS) polymict ureilite fell in 2008 when asteroid 2008 TC3 impacted over Sudan]. It is the first meteorite to originate from an asteroid that had been tracked and studied in space (with spectral classification) before impact, and provides a unique opportunity to correlate properties of meteorites with those of their parent asteroid. More than 700 monolithologic stones from the AhS fall were collected. Of those previously studied, approx. 70% were ureilites and approx. 30% were chondrites. It has been inferred that 2008 TC3 was loosely aggregated and porous and disintegrated in the atmosphere, with only its most coherent clasts falling as stones. However, understanding the structure of this asteroid is limited by incomplete study of the heterogeneous stones, and the loss of most of the mass of the asteroid. The University of Khartoum (UOK) AhS collection contains over >600 AhS stones with find coordinates. We are studying this collection to determine: 1) the proportion of ureilitic to various non-ureilitic stones; 2) the distribution of types of stones in the strewn field; and 3) the compositional and physical structure of 2008 TC3. We report on 61 new stones, including a unique sample that may represent the bulk of the material lost from 2008 TC3.

  10. Project W-049H Collection System Acceptance Test

    International Nuclear Information System (INIS)

    Buckles, D.I.

    1994-01-01

    The Acceptance Test Procedure (ATP) Program for Project W-049H covers the following activities: Disposal system, Collection system, Instrumentation and control system. Each activity has its own ATP. The purpose of the ATPs is to verify that the systems have been constructed in accordance with the construction documents and to demonstrate that the systems function as required by the Project criteria. This ATP has been prepared to demonstrate that the Collection System Instrumentation functions as required by project criteria

  11. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  12. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    Science.gov (United States)

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  14. Project W-049H collection system Acceptance Test Procedure

    International Nuclear Information System (INIS)

    Carrigan, M.C.

    1994-01-01

    The purpose of this Acceptance Test Procedure (ATP) for the Project W-049H, Treated Effluent Disposal Facility, is to verify that the collection system equipment installed as Pump Station No. 1 (225-W) and Pump Station No. 2 (225-E) have been installed in accordance with the design documents and function as required by the project criteria. This will be a wet test with potable water being introduced into the pump pits to test for leakage. Potable water will also be employed in the testing of the pumps and related mechanical equipment. All Instrument and Control equipment related to the pump stations will be checked electronically with simulated inputs/outputs when actual input/output signals are unavailable. Water from Pump Station 1 will be moved through the TEDF piping system and discharged into the disposal ponds. This will check the proper function of the air/vac valves not tested during construction, and the automated samplers

  15. Collection, pre-treatment and analyses of Cs-137 and Tc-99 in marine samples at the Institute of Marine Research (IMR), Norway

    International Nuclear Information System (INIS)

    Heldal, H.E.

    2010-01-01

    ]-impregnated filters and a flow-meter are mounted in a series directly on the ships water intake. About 200 L seawater are passed through the filters at a flow rate of 5 L/min. The filters are then dried at 60 deg. C for about 24 h and brought back to IMR where they are ashed at 450 deg. C and filled into 60 ml polyethylene counting boxes prior to analysis. Samples from the CTD-rosette multi-bottle sampler are shipped back to the laboratory and analysed using the ammonium molybdophosphate (AMP)-method. Biota, seawater and sediment samples are gamma-counted on Ortec HPGe-detectors with efficiencies ranging from 30 to 60 %, electric cryostat cooling systems, and 10 cm lead shieldings. For the analysis of Tc-99, 50-100 L of seawater is collected from the shipboard pump (surface samples) or CTD-rosette multi-bottle sampler (samples from the water column) and filled into 25 L polyethylene carboys. A known amount of rhenium (Re) is added to each sample as a carrier and yield monitor on board the ship. Further, the samples are passed through anion exchange resins made of BioRad AGx8 (100-200 mesh) packed into 60 ml disposable polystyrene syringes. The syringes containing the anion exchange resin are brought back to IMR for further radiochemical treatment. A RISOe beta-counter is used for beta-counting for Tc-99. Information about salinity and temperature of the seawater is normally available from the stations we collect samples. This information is important while interpreting the results. Samples of biota and sediments are collected for analysis of different hydrocarbons and persistent organic pollutants (POPs) from the same stations as the radionuclide samples. Combining these results gives us a more overall picture of the pollution load. (author)

  16. On the separation of 99mTcO4-, 99mTc-DTPA and 99mTc-citrate as marker species for the determination of Tc chemical forms in plant material using capillary zone electrophoresis

    NARCIS (Netherlands)

    Krijger, G.C.; Claessens, H.A.; Wolterbeek, H.Th.

    1996-01-01

    The present paper addresses the potential use of capillary zone electrophoresis (CZE) as an anal. tool in 99Tc speciation studies. To optimize sampling, storage and anal. procedures, the three marker compds. 99mTcO4-, 99mTc-DTPA and 99mTc-citrate were synthesized and used in test-measurements with

  17. Utility evaluation on application of geometric mean depending on depth of kidney in split renal function test using 99mTc-MAG{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Byeul; Ahn, Sung Min [Dept. of Radiological Science, Gachon University, Incheon (Korea, Republic of); Lee, Wang Hui [Dept. of Nuclear Medicine, Gil-Hospital, Incheon (Korea, Republic of)

    2016-06-15

    99mTc-MAG{sub 3} Renal scan is a method that acquires dynamic renal scan image by using 99mTc-MAG{sub 3} and dynamically visualizes process of radioactive agent being absorbed to kidney and excreted continuously. Once the test starts, ratio in both kidneys in 1-2.5 minutes was measured to obtain split renal function and split renal function can be expressed in ratio based on overall renal function. This study is based on compares split renal function obtained from data acquired from posterior detector, which is a conventional renal function test method, with split renal function acquired from the geometric mean of values obtained from anterior and posterior detectors, and studies utility of attenuation compensation depending on difference in geometric mean kidney depth. From July, 2015 to February 2016, 33 patients who undertook 99mTc-MAG{sub 3} Renal scan(13 male, 20 female, average age of 44.66 with range of 5-70, average height of 160.40 cm, average weight of 55.40 kg) were selected as subjects. Depth of kidney was shown to be 65.82 mm at average for left and 71.62 mm at average for right. In supine position, 30 out of 33 patients showed higher ratio of deep-situated kidney and lower ratio of shallow-situated kidney. Such result is deemed to be due to correction by attenuation between deep-situated kidney and detector and in case where there is difference between the depth of both kidneys such as, lesions in or around kidney, spine malformation, and ectopic kidney, ratio of deep-situated kidney must be compensated for more accurate calculation of split renal function, when compared to the conventional test method (posterior detector counting)

  18. Contribution of 99mTc-DTPA dynamic renal scintigraphy with furosemide test in the exploration of low grade urethra-pelvic junction syndrome. Report of 17 cases

    International Nuclear Information System (INIS)

    Ghfir, I.; Ben Rais, N.

    2009-01-01

    Introduction The renal scintigraphy using 99m Tc-DTPA with furosemide test constitutes a noninvasive and functional method that is of appreciable interest in the exploration of the upper urinary tract and in the evaluation of the separate renal function. It distinguishes the functional character of dilation from organic obstruction needing surgery or endoscopic treatment. Material and methods We report, through this work, the observations of 17 patients with a low grade urethra-pelvic junction syndrome detect by intravenous urography (I.V.U.). 99m Tc-DTPA renal scintigraphy with furosemide test was carried out among all our patients by means of a gamma-camera with large field equipped with a low energy high-resolution parallel collimator. The evaluation of images obtained consisted of analysis of urethra-pelvic permeability taking into account the semiquantitative parameters of time-activity curve or isotopic nephrogram (I.N.) obtained after digital reconstruction of sequential images. Results On the 17 studied cases, the sex-ratio was equal to 1.83; the average age was 18.92 years with extremes spanning from 4 years to 70 years. Renal scintigraphy categorized four patients groups. Group I: two patients (11.76%) with normal aspect of I.N.; group II; seven patients (41.17% of cases) with functional dilation; group III: five patients (29.41%) with organic obstruction and a group IV: three patients (17.64%) with intermediate response. Discussion 99m Tc-DTPA renal scintigraphy with furosemide test allowed, through our study, to obviate the limits of IVU and manometric explorations to distinguish functional dilation of organic obstruction. It permits the improvement of treatment with a favourable dosimetry. (authors)

  19. Utility evaluation on application of geometric mean depending on depth of kidney in split renal function test using 99mTc-MAG3

    International Nuclear Information System (INIS)

    Lee, Eun Byeul; Ahn, Sung Min; Lee, Wang Hui

    2016-01-01

    99mTc-MAG 3 Renal scan is a method that acquires dynamic renal scan image by using 99mTc-MAG 3 and dynamically visualizes process of radioactive agent being absorbed to kidney and excreted continuously. Once the test starts, ratio in both kidneys in 1-2.5 minutes was measured to obtain split renal function and split renal function can be expressed in ratio based on overall renal function. This study is based on compares split renal function obtained from data acquired from posterior detector, which is a conventional renal function test method, with split renal function acquired from the geometric mean of values obtained from anterior and posterior detectors, and studies utility of attenuation compensation depending on difference in geometric mean kidney depth. From July, 2015 to February 2016, 33 patients who undertook 99mTc-MAG 3 Renal scan(13 male, 20 female, average age of 44.66 with range of 5-70, average height of 160.40 cm, average weight of 55.40 kg) were selected as subjects. Depth of kidney was shown to be 65.82 mm at average for left and 71.62 mm at average for right. In supine position, 30 out of 33 patients showed higher ratio of deep-situated kidney and lower ratio of shallow-situated kidney. Such result is deemed to be due to correction by attenuation between deep-situated kidney and detector and in case where there is difference between the depth of both kidneys such as, lesions in or around kidney, spine malformation, and ectopic kidney, ratio of deep-situated kidney must be compensated for more accurate calculation of split renal function, when compared to the conventional test method (posterior detector counting)

  20. Hydrogen-induced room-temperature plasticity in TC4 and TC21 alloys

    DEFF Research Database (Denmark)

    Yuan, Baoguo; Jin, Yongyue; Hong, Chuanshi

    2017-01-01

    In order to reveal the effect of hydrogen on the room-temperature plasticity of the titanium alloys TC4 and TC21, compression tests have been carried out at room temperature. Results show that an appropriate amount of hydrogen can improve the room-temperature plasticity of both the TC4 and TC21...... alloys. The ultimate compression strain of the TC4 alloy containing a hydrogen concentration of 0.5 wt.% increases by 39% compared to the untreated material. For the TC21 alloy the ultimate compression strain is increased by 33% at a hydrogen concentration of 0.6 wt.%. The main reason for the improvement...... of hydrogen-induced room-temperature plasticity of the TC4 and TC21 alloys is discussed....

  1. 40 CFR 1065.520 - Pre-test verification procedures and pre-test data collection.

    Science.gov (United States)

    2010-07-01

    ... corrective action does not resolve the deficiency, you may request to use the contaminated system as an... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Pre-test verification procedures and pre-test data collection. 1065.520 Section 1065.520 Protection of Environment ENVIRONMENTAL PROTECTION...

  2. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology...

  3. Testing the validity of a receptor kinetic model via TcNGA functional imaging of liver transplant recipients. Final report

    International Nuclear Information System (INIS)

    Stadalnik, R.C.

    1993-01-01

    The author had accomplished the expertise for I-125-HSA plasma volume, galactose clearance for determination of hepatic plasma flow as well as finalizing the kinetic model. They have just completed modifying the microscale Scatchard assay for greater precision of receptor measurement using only 5--10 mg of liver tissue. In addition, he determined during the past year that the most practical method and clinically reasonable measurement of liver volume was to measure the transplanted liver in vivo using Tc-NGA images in the anterior, posterior, and right lateral projections, using the method of Rollo and DeLand. Direct measurement of liver weight obtained during transplant operation was not reliable due to variability of fluid retention in the donor liver secondary to ischemia, preservation fluid, etc., which thereby did not reflect an accurate liver weight which is needed in the kinetic analysis comparison, i.e., V h (hepatic plasma volume)

  4. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members.

    Science.gov (United States)

    Närhi, M; Natri, O; Desbois, I; Kinggaard Holm, D; Galea, G; Aranko, K; Korhonen, M; Nordstrom, K

    2013-11-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization. An online questionnaire was used for data collection in 2011, and 43 replies were received covering 71 product answers from 13 countries. Estimated percentages of tissue and cell banking covered by EBA member blood banks as a proportion of all collections of each individual country varied markedly. There were also major differences in the amounts of products collected and discarded and in proportions tissues provided for grafting. However, discarding of certain collections also reflects the practice of increasing the likelihood of the very best units being used for transplantation. Harmonization of possible practices should focus on matching supply with demand and on identifying the most efficient operators. This could allow for the development of practices for minimizing unnecessary collections. © 2013 International Society of Blood Transfusion.

  5. Collection and cultivation methods of Acartia tonsa for toxicity testing

    International Nuclear Information System (INIS)

    Hood, C.A.; Mayo, R.R.

    1995-01-01

    Acartia tonsa were located and collected from Galveston Bay, Texas in June 1995, using plankton nets and transported to the laboratory for culture. After literature searching and laboratory experimentation. A simple reliable method was designed to culture A. tonsa. This method requires a minimum of glassware and supplies. Adult A. tonsa are placed in one gallon bell jars filled with natural seawater. The jars are then maintained in a water bath at a constant temperature. Water changes are conducted twice weekly and organisms are fed daily with a mixture of algae, Skeletonema costatum, isocrysis galbana, and Thalassiosira sp. Gravid females are then isolated in generators for 24 hours to obtain known age neonates. The neonates are maintained up to a specific age and then are used in toxicity tests such as the ''Determination of the Acute Lethal Toxicity to Marine Copepods,'' required in the United Kingdom for all chemicals used for offshore drilling fluid applications

  6. Soil-to-plant transfer of 99mTc: how to determine Tc-species in uptake and transport processes?

    International Nuclear Information System (INIS)

    Krijger, G. C.; Van Elswijk, D. A.; Wolterbeek, H. Th.

    1995-01-01

    Selective extraction, filtration and capillary electrophoresis were used to recognize problems dealing with complexation, oxidation and ligand-exchange processes during collection and analysis of Tc-species in xylem exudates, while 99m Tc-citrate was used as a marker complex. Relatively unstable Tc-species were synthesized in xylem exudates. Oxidation of relative unstable Tc-species during the collection of xylem exudates was suggested, requiring new, better procedures to recognize Tc-species representative for the plant interior. (author)

  7. Test gear and measurements a collection of useful and tested circuit design ideas'

    CERN Document Server

    Stewart OBE DLitthc, David

    2013-01-01

    This book provides a clear introduction to test gear in the field of electronics. As well as being a first guide to test gear and its use, the book includes much practical information and reference material for the more experienced electronics enthusiast or student.Based on a collection of feature articles originally published in Electronics - the Maplin Magazine, this work by Danny Stewart is sure to be useful to electronics constructors, students and experimenters alike. Details of all the common (and some not-so-common) items of test gear are included, alongside information regarding its us

  8. 99mTc-IgG-Lung Scintigraphy in the Assessment of Pulmonary Involvement in Interstitial Lung Disease and Its Comparison With Pulmonary Function Tests and High-Resolution Computed Tomography: A Preliminary Study

    International Nuclear Information System (INIS)

    Bahtouee, Mehrzad; Saberifard, Jamshid; Javadi, Hamid; Nabipour, Iraj; Malakizadeh, Hasan; Monavvarsadegh, Gholamhossein; Ilkhani Pak, Hoda; Sadeghi, Azadeh; Assadi, Majid

    2015-01-01

    The discrimination of inactive inflammatory processes from the active form of the disease is of great importance in the management of interstitial lung disease (ILD). The aim of this study was to determine the efficacy of 99mTc-IgG scan for the detection of severity of disease compared to high-resolution computed tomography (HRCT) and pulmonary function test (PFT). Eight known cases of ILD including four cases of Mustard gas (MG) intoxication and four patients with ILD of unknown cause were included in this study. A population of six patients without lung disease was considered as the control group. The patients underwent PFT and high-resolution computed tomography, followed by 99mTc-IgG scan. They were followed up for one year. 99mTc-IgG scan assessment of IgG uptake was accomplished both qualitatively (subjectively) and semiquantitatively. All eight ILD patients demonstrated a strong increase in 99mTc-IgG uptake in the lungs, compared to the control patients. The 99mTc-IgG scan scores were higher in the patient group (0.64[95% confidence interval(CI)=0.61-0.69])) than the control group (0.35 (0.35[95% CI=0.28-0.40]), (P<0.05)). In patients, a statistically significant positive correlation was detected between 99mTc-IgG scan and HRCT scores (Spearman’s correlation coefficient = 0.92, P < 0.008). The 99mTc-Human Immunoglobulin (HIG) scores were not significantly correlated with PFT findings (including FVC, FEV1, FEV1/FVC), O 2 saturation and age (P values > 0.05). There were no significant correlations between 99mTc-IgG score and HRCT patterns including ground glass opacity, reticular fibrosis and honeycombing (P value > 0.05). The present results confirmed that 99mTc-IgG scan could be applied to detect the severity of pulmonary involvement, which was well correlated with HRCT findings. This data also showed that the 99mTc-IgG scan might be used as a complement to HRCT in the functional evaluation of the clinical status in ILD; however, further studies are

  9. Cerebral blood flow assessed by brain SPECT with 99mTc-HMPAO utilising the acetazolamide test in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Lass, P.; Romanowicz, G.; Koseda-Dragan, M.

    1998-01-01

    Background: Cerebrovascular diseases are one of the most important complications of systemic lupus erythematosus (SLE). The diagnostic imaging of neuropsychiatric SLE complications presents many problems. This study was undertaken to investigate cerebral blood flow char s and its reactivity to hypercapnia by means of acetazolamide test in SLE patients. Methods: Brain SPECT studies using 99mTc-HMPAO were performed in 50 patients with SLE. Acetazolamide test was performed in 35 patients 3 days after the baseline study by means of repetitive scanning 20 min after i.v. injection of 1.0 g of acetazolamide. Results: Significant interhemispheric hypoperfusion areas were shown in 76.3% of all patients, 83.8% symptomatic and 63.1% asymptomatic. Patients with antiphospholipid syndrome showed multifocal perfusion deficits. The reaction of cerebral perfusion to acetazolamide was heterogenous and showed increase, decrease, no change or mixed reaction of baseline-study-found focal hypoperfusion. Acetazolamide test revealed hypoperfusion in two patients with normal baseline study. MRI scanning revealed cerebral lesions in 41% of patients. Conclusions: CBF asymmetries in symptomatic and asymptomatic patients with SLE are frequent. Regional CBF alterations seem to be different in patients with and without antiphospholipid syndrome. The part of the patients with SLE shows no or paradoxically inversed reaction to acetazolamide. (author)

  10. A numerical test of the collective coordinate method

    International Nuclear Information System (INIS)

    Dobrowolski, T.; Tatrocki, P.

    2008-01-01

    The purpose of this Letter is to compare the dynamics of the kink interacting with the imperfection which follows from the collective coordinate method with the numerical results obtained on the ground of the field theoretical model. We showed that for weekly interacting kinks the collective coordinate method works similarly well for low and extremely large speeds

  11. Gastric emptying scintigraphy: choice by in vitro test, of a new 99mTc marker to label solid phase and further analysis with the better radiopharmaceuticals

    International Nuclear Information System (INIS)

    Blanc, F.

    2005-05-01

    The study of gastric emptying by isotopic method occurs regularly in Brest nuclear medicine department. It consists in eating radiolabelled omelette with rhenium sulphide macro-colloid and in drinking radiolabelled water with 111 In-DTPA. The two phases are followed in stomach with gamma-camera. Rhenium sulphide macro-colloid have been taken off the market in january 2004 and no radiopharmaceutical has replaced them. in vitro test permitted us to test solid phase radiolabeling stability with 5 99m Tc-vectors used in nuclear medicine. Two of them are suitable for gastric emptying solid phase labelling: the tin fluoride colloids and the sodium phytate but tin fluoride colloids give better labelling stability than sodium phytate. In order to define solid phase marker properties, studies of medium composition by X fluorescence, size by laser granulometry, structure by NMR (nuclear magnetic resonance), TLC (thin layer chromatography) and by centrifugation are done either with the two vectors or only with sodium phytate. Structural properties of tin fluoride colloids are known. Results of this study indicate that phytates can be colloids. Finally, the good gastric emptying solid phase marker must be a colloid with a size of about 200 nm. (author)

  12. Prospects for the use of high-Tc superconductors in fusion magnets and options for their test in SULTAN

    International Nuclear Information System (INIS)

    Wesche, Rainer; Bruzzone, Pierluigi; March, Stephen; Marinucci, Claudio; Stepanov, Boris; Uglietti, Davide

    2013-01-01

    Highlights: ► RE-123 tapes j c ≥ 500 A/cm (77 K) would enable fusion magnets operating above 20 K. ► Quench studies indicate that the protection of RE-123 fusion magnets is a challenge. ► Possibilities to test 50 kA class HTS conductors in SULTAN have been identified. ► HTS bus bar of large thermal resistance needed to connect sample and NbTi flux pump. ► Tests in the 20–50 K range require additional changes in the SULTAN cryogenics. -- Abstract: In the last few years, the critical current densities of long commercially available REBa 2 Cu 3 O 7−x (RE-123, where RE represents Y or a rare earth element) coated conductors have reached values of 250 A/cm-width at 77 K and zero applied field. Even higher values of 600 A/cm-w (77 K, B = 0) have been demonstrated in shorter lengths. The attractive features of the use of these high-T c superconductors (HTS) are operation temperatures above 20 K and/or magnetic fields higher than those envisaged for the ITER TF coils. Possible operation conditions for HTS fusion magnets have been studied taking into consideration the possible further improvements of RE-123 coated conductors. Investigations of stability and quench behavior indicate that stability is not a problem, whereas quench detection and protection need attention. Because of the high currents necessary for fusion magnets, many tapes need to be assembled into a transposed conductor. The qualification of HTS conductors for fusion magnets would require their test at magnetic fields of 11 T and currents well above 10 kA. The possibilities to test straight HTS conductor samples in SULTAN have been considered. For a test at 4.5 K, only the development of a low resistance joint between the HTS conductor under test and the NbTi transformer of SULTAN would be necessary. Tests up to 20 K would require that the HTS sample is connected with the NbTi transformer by a conduction-cooled HTS bus bar of large thermal resistance similar to the HTS module of a current

  13. ACER Chemistry Test Item Collection. ACER Chemtic Year 12.

    Science.gov (United States)

    Australian Council for Educational Research, Hawthorn.

    The chemistry test item banks contains 225 multiple-choice questions suitable for diagnostic and achievement testing; a three-page teacher's guide; answer key with item facilities; an answer sheet; and a 45-item sample achievement test. Although written for the new grade 12 chemistry course in Victoria, Australia, the items are widely applicable.…

  14. Determination of Tc-99 in radioactive wastes

    International Nuclear Information System (INIS)

    Rivera S, A. A.

    2015-01-01

    Tc-99 is a fission product and one of the most important radionuclides from the view point of safety assessment for the disposal of radioactive waste because of its long half-life (2.1 x 10 5 years) and high mobility in soil-water systems, if this is released into the environment in significant quantities can concentrate on plants and animals. Tc-99 is a pure beta emitter with a maximum energy of 292 KeV, so their quantification imposes destructive methods to be analyzed by liquid scintillation. Therefore the quantification of Tc-99 in ion exchange resins requires of the mineralization of these and separation of Tc-99 of other radioisotopes present in the resin. Therefore the object of this thesis is to develop a quantification method of Tc-99 content in spent exchange resins. So in order to track the behavior of technetium during digestion exchange resins and radiochemical separation, given its high volatility, in this work the 99m Tc is used. To determine the degree of mineralization of the resins, an analysis was performed by chromatography. Subsequently the method used to determine the percentage of 99m Tc aerosolized during mineralization of resin is described. After the method for the radiochemical separation of 99m Tc is presented by liquid-liquid extraction using crown ether as extractant; for this testing was performed by varying the molarity of the extractant, the ratio of solvent extractant, type of digestion of the resin and the presence of Sr-85, in order to study the behavior of 99m Tc in the presence of this radioisotope. Finally, a track beta spectra of a sample of 99m Tc eluted from a generator 99 Mo/ 99m Tc function of time was performed. (Author)

  15. Clinical evaluation of scintigraphies with sup(99m)Tc-phytate and /sup 67/Ga-citrate as a screening test for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ayabe, Y; Oshiumi, Y; Kamoi, I; Ichiya, Y [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine; Murakami, J

    1981-02-01

    sup(99m)Tc-phytate and /sup 67/Ga-citrate scintigraphies were evaluated clinically in 50 cases of histologically proven hepatocellular carcinoma. Detectability was higher in sup(99m)Tc-phytate scans than in /sup 67/Ga scans, and was influenced by the presence of liver cirrhosis. However, by using both scans, the highest detectability was obtained. /sup 67/Ga scan was useful especially in cases with equivocal sup(99m)Tc-phytate scintigraphy and cases with liver cirrhosis. There was no definite correlation seen between Edmondson's histological gradings and grades of /sup 67/Ga accumulation. No significant difference of /sup 67/Ga accumulation in hepatocellular carcinoma was observed regardless of the presence of liver cirrhosis. We conclude that it is better to use sup(99m)Tc-phytate as the first choice in screening of hepatocellular carcinoma and subsequent /sup 67/Ga scan if indicated.

  16. 99mTc-EDTA and 99mTc-DTPA complexes as hydrological tracers

    International Nuclear Information System (INIS)

    Dominguez, J.; Borroto, J.; Nazco, J.; Perez, E.; Gamboa, R.; Cruz, J.

    2002-01-01

    The [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1- were evaluated as radiotracers for short time hydrological studies. Their complex stability after labelling with 9.25 GBq of 99m Tc, the behaviour against pH variations, from 5 to 9, in simulated solutions and in natural river waters and the sorption of these compounds on the river sediments, were tested in laboratory experiments. Finally field double tracing experiments were carried out for each of labelling complexes and Rhodamine WT. From recovery calculations not losses of the 99m Tc activity were observed. The shape of the RTD curves of the [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1 were quite similar to the Rhodamine Wt ones. May be concluded that both complexes behaved conservatively on the studied environmental conditions. (author)

  17. Science Library of Test Items. Volume Twenty-Two. A Collection of Multiple Choice Test Items Relating Mainly to Skills.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  18. Science Library of Test Items. Volume Eighteen. A Collection of Multiple Choice Test Items Relating Mainly to Chemistry.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  19. Science Library of Test Items. Volume Twenty. A Collection of Multiple Choice Test Items Relating Mainly to Physics, 1.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  20. Science Library of Test Items. Volume Seventeen. A Collection of Multiple Choice Test Items Relating Mainly to Biology.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  1. Science Library of Test Items. Volume Nineteen. A Collection of Multiple Choice Test Items Relating Mainly to Geology.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  2. 99m-Tc-IDA scintigraphic demonstrability of biliary elements and liver function tests in hepatobiliary diseases

    International Nuclear Information System (INIS)

    Kim, C.Y.; Bahk, Y.W.

    1982-01-01

    In the present communication, the results will be reported on a clinical study of how well scintigraphic visualization of the hepatobiliary elements and several commonly used clinical liver function tests correlate each other in various diseases of the hepatobiliary system. The demonstrability of the biliary tract, gallblader (GB) and duodenum was rather closely paralleled to serum bilirubin level and less closely to alkaline phosphatase and rather poorly to SGOT and SGPT. The biliary tree could not be visualized scintigraphically when bilirubin exceeded 10 mg/dl

  3. Side-suspended High- Tc Superconducting Maglev Prototype Vehicle Running at a High Speed in an Evacuated Circular Test Track

    International Nuclear Information System (INIS)

    Zhou, Dajin; Zhao, Lifeng; Cui, Chenyu; Zhang, Yong; Guo, Jianqiang; Zhao, Yong

    2017-01-01

    High- T c superconductor (HTS) and permanent magnetic guideway (PMG) based maglev train is intensively studied in China, Japan, Germany and Brazil, mainly through static or vibration test. Amongst these studies, only a few of reports are available for the direct and effective assessment on the dynamic performance of the HTS maglev vehicle by running on a straight or circular PMG track. The highest running speed of these experiments is lower than 50 km/h. In this paper, a side-suspended HTS permanent magnetic guideway maglev system was proposed and constructed in order to increase the running speed in a circular track. By optimizing the arrangement of YBCO bulks besides the PMG, the side-suspended HTS maglev prototype vehicle was successfully running stably at a speed as high as 150 km/h in a circular test track with 6.5 m in diameter, and in an evacuated tube environment, in which the pressure is 5 × 10 3 Pa. (paper)

  4. Non-destructive testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

    Energy Technology Data Exchange (ETDEWEB)

    Lu, D.F.; Fan, C.; Ruan, J.Z. [Midwest Superconductivity Inc., Lawrence, KS (United States)] [and others

    1994-12-31

    A SQUID is the most sensitive device to detect change in magnetic field. A non-destructive testing (NDT) device using high temperature SQUIDs and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUIDs. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology.

  5. Non-destructive testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

    International Nuclear Information System (INIS)

    Lu, D.F.; Fan, C.; Ruan, J.Z.

    1994-01-01

    A SQUID is the most sensitive device to detect change in magnetic field. A non-destructive testing (NDT) device using high temperature SQUIDs and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUIDs. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology

  6. Travel Time Data Collection Field Tests - Lessons Learned

    Science.gov (United States)

    1999-06-28

    The Los Angeles Spread Spectrum Radio (SSR) Traffic Signal Interconnect Field Operational Test (FOT) investigated the feasibility of using wireless communications as an alternative to traditional hard-wire interconnection, to extend the coverage of c...

  7. Automating the simulator testing and data collection process

    Energy Technology Data Exchange (ETDEWEB)

    Magi, T.; Dimitri-Hakim, R. [L-3 Communications MAPPS Inc., Montreal, Quebec (Canada)

    2012-07-01

    Scenario-based training is a key process in the use of Full Scope Simulators (FSS) for operator training. Scenario-based training can be defined as any set of simulated plant operations performed with a specific training objective in mind. In order to meet this training objective, the ANSI/ANS-3.5-2009 standard requires that certain simulator training scenarios be tested to ensure that they reproduce the expected plant responses, that all plant procedures can be followed, and that scenario-based training objectives can be met. While malfunction testing provided a narrow view of the simulator performance revolving around the malfunction itself, scenario testing provides a broader, overall view. The concept of instructor validation of simulator scenarios to be used for training and evaluation, and oversight of simulator performance during the validation process, work hand-in-hand. This is where Scenario-Based Testing comes into play. With the description of Scenario-Based Testing (SBT) within Nuclear Energy Institute NEI 09-09 white paper and within the ANSI/ANS-3.5-2009 standard, the industry now has a way forward that reduces the regulatory uncertainty. Together, scenario-based testing and scenario-based training combine to produce better simulators which in turn can be used to more effectively and efficiently train new and existing power plant operators. However, they also impose a significant data gathering and analysis burden on FSS users. L-3 MAPPS Orchid Instructor Station (Orchid IS) facilitates this data gathering and analysis by providing features that automate this process with a simple, centralized, easy to use interface. (author)

  8. Microstructural characterization and tribological behavior of surface plasma Zr-Er alloying on TC11 alloy

    Science.gov (United States)

    Wei, Dongbo; Zhang, Pingze; Liu, Yingchao; Chen, Xiaohu; Ding, Feng; Li, Fengkun

    2018-02-01

    The Zr coating and Zr-Er coating are grown on TC11 substrate by double-glow plasma surface metallurgy technique, followed by the wear tests at ambient temperature and 500 °C. The data of nanohardness and elastic modulus of the samples are collected by the nano-indentation test. The adhesion strength of coatings is investigated by means of the scratch test. The study of wear resistance is performed using a ball-on-disc wear test system by running against the Si3N4 ball and measured by scanning electron microscope (SEM) and X-ray diffraction (XRD). Experimental results indicate that the nanohardness of the Zr coating and Zr-Er coating are 5.94 GPa and 7.98 GPa, respectively, which are 1.79 times and 2.41 times greater than that of TC11 substrate. Zr coating and Zr-Er coating realize the metallurgical bonding with TC11 substrate with continuous and compact structure. Compared with the Zr coating and TC11, the Zr-Er coating presents the lowest specific wear rates, which are 1.689 × 10-6 mm3 Nm-1 and 1.851 × 10-6 mm3 Nm-1 at ambient temperature and 500 °C respectively, indicating the excellent and improved wear resistance of TC11.

  9. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S. [Centro de Diagnostico Fleury, Sao Paulo, SP (Brazil). Secao de Medicina Nuclear; Sao Paulo Univ. (USP), SP (Brazil). Escola de Saude Publica. Dept. de Epidemiologia]. E-mail: paulo.duarte@fleury.com.br

    2006-07-15

    Objective: The aim of this study was to compare the renal function measured with either {sup 99m}Tc-DTPA or {sup 99m}Tc-EC dynamic scintigraphies with that measured using {sup 99m}Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with {sup 99m}Tc-DTPA (55 studies) or with {sup 99m}Tc-EC (56 studies) were compared with the relative function measured using {sup 99m}Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of {sup 99m}Tc-DTPA and {sup 99m}Tc-EC studies that presented relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with {sup 99m}Tc-EC is not statistically different from that measured with {sup 99m}Tc-DMSA (p = 0.97). The relative renal function measured with {sup 99m}Tc-DTPA was statistically different from that measured using {sup 99m}Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA is higher for the {sup 99m}Tc-DTPA scintigraphy (p 0.04) than for {sup 99m}Tc-EC. Conclusion: the relative renal function measured with {sup 99m}Tc-EC dynamic scintigraphy is comparable with that measured with {sup 99m}Tc-DMSA static scintigraphy, while the relative renal function measured with {sup 99m}Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with {sup 99m}Tc-DMSA static scintigraphy. (author)

  10. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    International Nuclear Information System (INIS)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S.; Sao Paulo Univ.

    2006-01-01

    Objective: The aim of this study was to compare the renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured using 99m Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99m Tc-DTPA (55 studies) or with 99m Tc-EC (56 studies) were compared with the relative function measured using 99m Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of 99m Tc-DTPA and 99m Tc-EC studies that presented relative renal function different by more than 5% from that measured with 99m Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with 99m Tc-EC is not statistically different from that measured with 99m Tc-DMSA (p = 0.97). The relative renal function measured with 99m Tc-DTPA was statistically different from that measured using 99m Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with 99m Tc-DMSA is higher for the 99m Tc-DTPA scintigraphy (p 0.04) than for 99m Tc-EC. Conclusion: the relative renal function measured with 99m Tc-EC dynamic scintigraphy is comparable with that measured with 99m Tc-DMSA static scintigraphy, while the relative renal function measured with 99m Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with 99m Tc-DMSA static scintigraphy. (author)

  11. 77 FR 10509 - Agency Information Collection Activities; Proposed Collection; Comment Request; Drug Testing for...

    Science.gov (United States)

    2012-02-22

    ... that may potentially affect communities and the surrounding environment. Releases may be accidental... may be responsible for testing their employees for the use of marijuana, cocaine, opiates.... Respondents/Affected Entities: EPA contractor employees who work at sensitive sites. Estimated Number of...

  12. Live Operation Data Collection Optimization and Communication for the Domestic Nuclear Detection Office's Rail Test Center

    International Nuclear Information System (INIS)

    Gelston, Gariann M.

    2010-01-01

    For the Domestic Nuclear Detection Office's Rail Test Center (i.e., DNDO's RTC), port operation knowledge with flexible collection tools and technique are essential in both technology testing design and implementation intended for live operational settings. Increased contextual data, flexibility in procedures, and rapid availability of information are keys to addressing the challenges of optimization, validation, and analysis within live operational setting data collection. These concepts need to be integrated into technology testing designs, data collection, validation, and analysis processes. A modified data collection technique with a two phased live operation test method is proposed.

  13. Pharmacokinetics and radiation dosimetry of 99mTc-3PRGD2 in healthy individuals: A pilot study

    International Nuclear Information System (INIS)

    Cheng Guanghui; Gao Shi; JI Tiefeng; Ma Qingjie; Wang Qing; Jia Bing; Chen Zuowei

    2012-01-01

    99m Tc-3PRGD 2 is a new SPECT radiotracer for several tumor imaging with high uptake where integrin α v β 3 is highly expressed. This pilot study was to assess the safety, biodistribution and radiation dosimetry of 99m Tc-3PRGD 2 in healthy volunteers. The 10 healthy male volunteers were injected with 99m Tc-3PRGD 2 (786.7±55.8 MBq, 19.1-24.2 mCi). Baseline measurements of vital signs, laboratory safety tests and 12-lead electrocardiogram were recorded before and after injection. Blood and urine samples were collected and radiation counts were obtained at various time points. Whole-body scans and ROIs of identified organs were used for visual analysis and estimating the radiation dosimetry. No adverse reactions were found during the study. 99m Tc-3PRGD 2 exhibited a rapid clearance from the blood with less than 45% of the initial dosage at 10 min after injection and gradual increasing radioactivity in urine with (52.9±6)% of original dose at 1440 min. The whole-body imaging showed high radioactive accumulation in bladder. And the highest 99m Tc-3PRGD 2 uptake was found in the kidneys (3.50×10 -2 mSv/MBq). The 99m Tc-3PRGD 2 exhibited good pharmacokinetic properties and little radiation burden. This study showed that 99m Tc-3PRGD 2 would be a safe and attractive SPECT agent in clinic applications. (authors)

  14. The formation of insoluble Tc depends on bacterial activity

    International Nuclear Information System (INIS)

    Ishii, Nobuyoshi; Uchida, Shigeo; Koiso, Hiroyuki

    2005-01-01

    The formation of insoluble Tc (>0.2 μm in size) in ponding water of paddy soil was investigated. The ponding water prepared by flooding with deionized water was collected at a one-week intervals during the 120 days of the experimental period. The collected sample was incubated with 3 kBq mL -1 TcO 4 - at 25degC for 14 days. The mean value of relative amounts of insolubilized Tc was less than 0.6% of total Tc. This result suggested that flooding with deionized water was not effective for the formation of insoluble Tc. When the ponding water sample was incubated with TcO 4 - under anaerobic conditions, Tc was scarcely insolubilized. On the other hand, a significant fraction of the Tc was insolubilized in the ponding water sample supplemented with nutrients that promote bacterial activity. Also, the amount of insoluble Tc increased with time. From these results, it was concluded that the formation of insoluble Tc in the ponding water depends on enhanced bacterial activity rather than just anaerobic conditions. (author)

  15. Determination of Tc-99 in radioactive wastes; Determinacion de Tc-99 en desechos radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Rivera S, A. A.

    2015-07-01

    Tc-99 is a fission product and one of the most important radionuclides from the view point of safety assessment for the disposal of radioactive waste because of its long half-life (2.1 x 10{sup 5} years) and high mobility in soil-water systems, if this is released into the environment in significant quantities can concentrate on plants and animals. Tc-99 is a pure beta emitter with a maximum energy of 292 KeV, so their quantification imposes destructive methods to be analyzed by liquid scintillation. Therefore the quantification of Tc-99 in ion exchange resins requires of the mineralization of these and separation of Tc-99 of other radioisotopes present in the resin. Therefore the object of this thesis is to develop a quantification method of Tc-99 content in spent exchange resins. So in order to track the behavior of technetium during digestion exchange resins and radiochemical separation, given its high volatility, in this work the {sup 99m}Tc is used. To determine the degree of mineralization of the resins, an analysis was performed by chromatography. Subsequently the method used to determine the percentage of {sup 99m}Tc aerosolized during mineralization of resin is described. After the method for the radiochemical separation of {sup 99m}Tc is presented by liquid-liquid extraction using crown ether as extractant; for this testing was performed by varying the molarity of the extractant, the ratio of solvent extractant, type of digestion of the resin and the presence of Sr-85, in order to study the behavior of {sup 99m}Tc in the presence of this radioisotope. Finally, a track beta spectra of a sample of {sup 99m}Tc eluted from a generator {sup 99}Mo/{sup 99m}Tc function of time was performed. (Author)

  16. Comparative investigation of the gel chromatography column scanning method for quality control of /sup 99/sup(m)Tc-methylenediphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Darte, L

    1981-04-01

    Gel chromatography column scanning (GCS) is the method of choice for quality control of sup(99m)Tc-MDP preparations. Using this method all the labelled components are obtained rapidly in one simple test procedure. The influence of various parameters such as gel type, column size, prehistory of column, equilibration, eluent, elution volume and flow rate upon the results have been investigated. Test results for sup(99 m)Tc-MDP have been compared for several different GCS systems, a few TLC systems and column chromatography with fraction collection. The GCS technique, optimized for testing sup(99m)Tc-MDP preparations has been applied in a few experiments in which very good reproducibility is required: Labelling kinetics and stability when stored at room temperature or in a refrigerator and influence of the sup(99m)Te/(sup(99m)Tc + /sup 99/Tc) atomic ratio and of the amount of radioactivity on the sup(99m)Tc-MDP labelling yield, covering parameter ranges of clinical interest, have been studied.

  17. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Science.gov (United States)

    2010-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§ 864.3260...

  18. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members

    DEFF Research Database (Denmark)

    Närhi, M; Natri, O; Desbois, I

    2013-01-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB......) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization....

  19. The data collection system for failure/maintenance at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Casey, M.A.; Gruetzmacher, K.M.; Bartlit, J.R.; Cadwallader, L.C.

    1988-01-01

    A data collection system for obtaining information which can be used to help determine the reliability and vailability of future fusion power plants has been installed at the Los Alamos National Laboratory's Tritium Systems Test Assembly (TSTA). Failure and maintenance data on components of TSTA's tritium systems have been collected since 1984. The focus of the data collection has been TSTA's Tritium Waste Tratment System (TWT), which has maintained high availability since it became operation in 1982. Data collection is still in progress and a total of 291 failure reports are in the data collection system at this time, 47 of which are from the TWT. 6 refs., 2 figs., 2 tabs

  20. Identification of novel mammalian hosts and Brazilian biome geographic distribution of Trypanosoma cruzi TcIII and TcIV.

    Science.gov (United States)

    Barros, Juliana Helena S; Xavier, Samanta Cristina C; Bilac, Daniele; Lima, Valdirene Santos; Dario, Maria Augusta; Jansen, Ana Maria

    2017-08-01

    Trypanosoma cruzi is a parasitic protozoan responsible for Chagas disease. Seven different Discrete Typing Units (DTUs) of T. cruzi are currently identified in nature: TcI-TcVI, and TcBat whose distribution patterns in nature, hosts/reservoirs and eco-epidemiological importance are still little known. Here, we present novel data on the geographic distribution and diversity of mammalian hosts and vectors of T. cruzi DTUs TcIII and TcIV. In this study, we analyzed 61 T. cruzi isolates obtained from 18 species of mammals (five orders) and two Hemiptera genera. Samples were collected from five Brazilian biomes (Pantanal, Caatinga, Cerrado, Atlantic Rainforest, and Amazon) previously characterized as Z3 or mixed infection (TcI-Z3) by mini-exon gene PCR. To identify TcIII and TcIV genotypes, we applied restriction fragment length polymorphism analysis to the PCR-amplified histone 3 gene. DTUs TcIII and TcIV were identified in single and mixed infections from wide dispersion throughout five Brazilian biomes studied, with TcIV being the most common. Pantanal was the biome that displayed the largest number of samples characterized as TcIII and TcIV in single and mixed infections, followed by Atlantic Rainforest and Amazon. Species from the Didelphimorphia order displayed the highest frequency of infection and were found in all five biomes. We report, for the first time, the infection of a species of the Artiodactyla order by DTU TcIII. In addition, we describe new host species: five mammals (marsupials and rodents) and two genera of Hemiptera. Our data indicate that DTUs TcIII and TcIV are more widespread and infect a larger number of mammalian species than previously thought. In addition, they are transmitted in restricted foci and cycles, but in different microhabitats and areas with distinct ecological profiles. Finally, we show that DTUs TcIII and TcIV do not present any specific association with biomes or host species. Copyright © 2017. Published by Elsevier B.V.

  1. FedWeb Greatest Hits: Presenting the New Test Collection for Federated Web Search

    NARCIS (Netherlands)

    Demeester, Thomas; Trieschnigg, Rudolf Berend; Zhou, Ke; Nguyen, Dong-Phuong; Hiemstra, Djoerd

    This paper presents 'FedWeb Greatest Hits', a large new test collection for research in web information retrieval. As a combination and extension of the datasets used in the TREC Federated Web Search Track, this collection opens up new research possibilities on federated web search challenges, as

  2. Test Report Emission Test Program EPA Information Collection Request for Delayed Coking Units 736 Coker Unit

    Science.gov (United States)

    ARI Environmental, Inc. (ARI) was retained by Houston Refining LP (HRO) to conduct an emission test program at their refinery located in Houston, Texas. The testing was conducted on on the 736 Delayed Coking Unit (DCU) in response to EPA's ICR.

  3. Direct {sup 99m}Tc labeling of Herceptin (trastuzumab) by {sup 99m}Tc(I) tricarbonyl ion

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.-J.; Yen, C.-L.; Lo, S.-T.; Chen, K.-T. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Lo, J.-M. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China)], E-mail: jmlo@mx.nthu.edu.tw

    2008-03-15

    By simply incubating Herceptin (trastuzumab) with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +} ion in saline, a significant yield of {sup 99m}Tc-labeled trastuzumab was found to be achievable. The effective labeling may be based on that trastuzumab is inherent with endogenous histidine group to which {sup 99m}Tc(I) tricarbonyl ion can be strongly bound. For practical {sup 99m}Tc labeling processing, trastuzumab was purified beforehand from the commercial product, Herceptin (Genentech) via size exclusion chromatography to remove the excipient, {alpha}-histidine and a high-labeled yield could be obtained by incubating the purified trastuzumab with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +}. Retention of bioactivity of the {sup 99m}Tc(I)-labeled trastuzumab was validated using a cell binding test.

  4. Acceptability of Sexually Transmitted Infection Testing Using Self-Collected Vaginal Swabs among College Women

    Science.gov (United States)

    Fielder, Robyn L.; Carey, Kate B.; Carey, Michael P.

    2013-01-01

    Objective: To assess the acceptability of sexually transmitted infection (STI) testing using self-collected vaginal swabs (SCVS) among college women. Participants: First-year female students ("N" = 483). Methods: Participants were offered free testing for 3 STIs using SCVS in April 2010 and later completed a survey regarding their…

  5. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of ... Conclusion: Acceptability of self-sampling for HPV testing was similarly excellent in both groups despite their difference in terms ... cancer is the leading cause of death caused by cancer in.

  6. A guide to archival collections relating to radioactive fallout from nuclear weapon testing

    International Nuclear Information System (INIS)

    Martin, B.W.

    1992-09-01

    This ninth edition of A Guide to Archival Collections Relating to Radioactive Fallout from Nuclear Weapon Testing constitutes History Associates Incorporated's (HAI) final report of its document collection, processing, and declassification efforts for the Nevada Field Office of the Department of Energy. The most significant feature of this edition is the updated HAI collection effort information. We confirmed the accuracy of this information using our screening, processing, and transmittal records. Unlike previous editions, funding limitations prevented us from systematically revising the collection descriptions and point-of-contact information for this final edition. This guide has been prepared by professional historians who have a working knowledge of many of the record collections included in the following pages. In describing materials, they have tried to include enough information so that persons unfamiliar with the complexities of large record systems will be able to determine that nature of the information in, and the quality of, each record collection

  7. Effect of milking efficiency on Tc-99 content of Tc-99m derived from Tc-99m generators

    International Nuclear Information System (INIS)

    Bonnyman, J.

    1983-01-01

    Tc-99m obtained by separation from its parent Mo-99 always contains Tc-99 produced by decay of Tc-99m and Mo-99. Factors effecting the Tc-99/Tc-99m ratios are discussed. An HPLC method has been developed to measure the 99 TcO 4- content of sodium pertechnetate from generators with a detection limit of 0.9 ng Tc-99 for a 500 μl/ aliquot of TcO 4- -99m. First eluates of 10 chromatograph-ic generators gave Tc-99/Tc-99m ratios ranging from 3.5-46 ng Tc/mCi Tc-99m measured at the time of milking. The measurements indicate that Tc-99/Tc-99m ratios high enough to cause adverse labelling effects could be found in 'instant pertechnetate' and in the first eluate from Tc-99m generators for the activities normally used in radiopharmaceutical production

  8. Quantitative study of 99mTc-Technegas SPECT for ventilatory impairment in pulmonary emphysema. Regional distribution. Correlation of SPECT with pulmonary function test

    International Nuclear Information System (INIS)

    Satoh, Katashi; Mitani, Masahiro; Yamamoto, Yuka; Nishiyama, Yoshihiro; Ohkawa, Motoomi

    2003-01-01

    99m Tc-Technegas scintigraphy is used for evaluation of abnormality of ventilation in pulmonary emphysema. Although the abnormality of ventilation distribution is very easy to find, there is not an objective index. The evaluation is subjective and different by each radiologist. It was also difficult to compare each cases and the clinical course in the same case. The present study for quantitative evaluation has proved that excellent correlations is obtained between the mean voxel values of the lung and stage classification. Furthermore, a correlation is observed between the mean and forced expiratory volume in 1 second (FEV 1.0 )%. These data indicate that quantitative analysis of SPECT seem to be useful to classify the clinical stage and compare the each cases. And respiratory function decreases as much as chronic pulmonary emphysema exists in the lower lung field. (author)

  9. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  10. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  11. Test Collections for Patent-to-Patent Retrieval and Patent Map Generation in NTCIR-4 Workshop

    OpenAIRE

    Fujii, Atsushi; Iwayama, Makoto; Kando, Noriko

    2004-01-01

    This paper describes the Patent Retrieval Task in the Fourth NTCIR Workshop, and the test collections produced in this task. We perform the invalidity search task, in which each participant group searches a patent collection for the patents that can invalidate the demand in an existing claim. We also perform the automatic patent map generation task, in which the patents associated with a specific topic are organized in a multi-dimensional matrix.

  12. 99Tc in the Irish Sea. Recent trends

    International Nuclear Information System (INIS)

    McCartney, M.; Rajendran, K.

    1997-01-01

    The increase in discharges of 99 Tc from Sellafield has resulted in an ideal opportunity to study the behaviour of this radionuclide in the aquatic environment. Results, thus far, have demonstrated that 99 Tc uptake by seaweeds collected from around the Irish Sea has followed the anticipated trend, with brown seaweeds accumulating 100-1000 times more 99 Tc than red or green algae. The large increase in discharges of 99 Tc from Sellafield in 1994 had been matched by a similar increase in the levels present in brown seaweeds, mussels and winkles for which concentration factors of 24000, 5000 and 100, respectively, have been derived. This confirms the observation that 99 Tc uptake by marine organisms in the field far exceeds that which would be expected from laboratory studies. Thus, it is concluded that, given the radiological importance of this nuclide, the provision of more accurate information on its environmental behaviour is required. (author)

  13. Feature test report for the Small Debris Collection and Packaging System

    International Nuclear Information System (INIS)

    Brisbin, S.A.

    1995-01-01

    The Spent Nuclear Fuel Equipment Engineering group performed feature testing of the Small Debris Collection and Packaging System (SDCPS) in the 305 Cold Test Facility from January 30, 1995, to February 1, 1995. Feature testing of the Small Debris Collection and Packaging System (SDCPS) was performed for the following reasons: To assess the feasibility of using ''drop-out'' vessels to collect small debris (<2.5 cm) in MK-II fuel canisters while transferring sludge to the Weasel Pit. To evaluate system performance under conditions similar to those in the K-Basins (e.g. submerged under 4.9 meters of water and operated with long handled tools) while using a surrogate sludge mixed with debris. To determine if canister weight could be used to predict the volume of sludge and/or debris contained within the canisters during system operation

  14. 99mTc tetrosfosmin mamoscintigraphy in the diagnose of the breast cancer

    International Nuclear Information System (INIS)

    Batista, Juan F.

    1997-01-01

    Background: Several radiopharmaceuticals such as Tc-99m Metoxi-isobutiol-isonitrile, Tc-99m MDP, Gallium Citrate and Thallium Chloride have been tested for the detection of breast cancer and lymph node involvement. To date, only report has been published related with the uptake of Tc-99m tetrosfosmin in one patient with breast cancer

  15. 78 FR 30899 - Agency Information Collection Activities; Comment Request; NCES Cognitive, Pilot, and Field Test...

    Science.gov (United States)

    2013-05-23

    ... requested data in the desired format. ED is soliciting comments on the proposed information collection... and methodologies. The procedures utilized to this effect include but are not limited to experiments... activities, pilot testing, exploratory interviews, experiments with questionnaire design, and usability...

  16. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of Madagascar. Materials and methods: Participants were recruited in a health care center (urban group) and smaller affiliated dispensaries (rural group). They were invited to perform ...

  17. 93Tc and sup(93m)Tc gamma spectra

    International Nuclear Information System (INIS)

    Podkopaev, Yu.N.; Zarubin, P.P.; Kobelev, V.F.; Padalko, V.Yu.; Khrisanfov, Yu.V.

    1977-01-01

    The sup(93,93m)Tc decay was studied. The spectra of γ-rays accompanying the decay of this nuclide were studied. 93 Tc and sup(93m)Tc were obtained in the (dn)-reaction on 92 Mo. To ensure a more reliable identification of γ-rays, the isotopic composition of the targets, the bombardment time, the energy of the bombarding deuterons (5-12 MeV) and the spectrum processing program were varied. The energies and relative intensities of the γ-rays of the 93 Tc and sup(93m)Tc decay are listed in tables together with data of other investigatxons. The results obtained largely confirm the known data. Four new transitions were added in the sup(93m)Tc spectrum namely 1046.8, 2011.8, 2182.0, and 2861.5 keV. The 2739.0 keV transition was eliminated from the 93 Tc spectrum. The appropriate changes and additions were made in the 93 Tc decay scheme, and three new levels were introduced: 2479.0, 2821.7, and 3025.8 keV. The values of log ft of some levels of 93 Tc were estimated

  18. The collection and analysis of transient test data using the mobile instrumentation data acquisition system (MIDAS)

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Arviso, M.

    1995-01-01

    Packages designed to transport radioactive materials are required to survive exposure to environments defined in Code of Federal Regulations. Cask designers can investigate package designs through structural and thermal testing of full-scale packages, components, or representative models. The acquisition of reliable response data from instrumentation measurement devices is an essential part of this testing activity. Sandia National Laboratories, under the sponsorship of the US Department of Energy (DOE), has developed the Mobile Instrumentation Data Acquisition System (MIDAS) dedicated to the collection and processing of structural and thermal data from regulatory tests

  19. Expanding the knowledge of the geographic distribution of Trypanosoma cruzi TcII and TcV/TcVI genotypes in the Brazilian Amazon.

    Directory of Open Access Journals (Sweden)

    Valdirene Dos Santos Lima

    Full Text Available Trypanosoma cruzi infection is a complex sylvatic enzooty involving a wide range of animal species. Six discrete typing units (DTUs of T. cruzi, named TcI to TcVI, are currently recognized. One unanswered question concerning the epidemiology of T. cruzi is the distribution pattern of TcII and hybrid DTUs in nature, including their virtual absence in the Brazilian Amazon, the current endemic area of Chagas disease in Brazil. Herein, we characterized biological samples that were collected in previous epizootiological studies carried out in the Amazon Basin in Brazil. We performed T. cruzi genotyping using four polymorphic genes to identify T. cruzi DTUs: mini-exon, 1f8, histone 3 and gp72. This analysis was conducted in the following biological samples: (i two T. cruzi isolates obtained by culturing of stools from the triatomine species Rhodnius picttipes and (ii five serum samples from dogs in which trypomastigotes were observed during fresh blood examination. We report for the first time the presence of TcII and hybrid DTUs (TcV/TcVI in the Amazon region in mixed infections with TcI. Furthermore, sequencing of the constitutive gene, gp72, demonstrated diversity in TcII even within the same forest fragment. These data show that TcII is distributed in the five main Brazilian biomes and is likely more prevalent than currently described. It is very probable that there is no biological or ecological barrier to the transmission and establishment of any DTU in any biome in Brazil.

  20. Stability of U(VI) and Tc(VII) Reducing Microbial Communities to EnvironmentalPerturbation: Development and Testing of a Thermodynamic Network Model. Technical Report

    International Nuclear Information System (INIS)

    Jonathan D. Istok

    2008-01-01

    'Bioimmobilization' of redox-sensitive metals and radionuclides is being investigated as a way to remediate contaminated groundwater and sediments. In this approach, growth-limiting substrates are added to stimulate the activity of targeted groups of indigenous microorganisms and create conditions favorable for the microbially-mediated precipitation ('bioimmobilization') of targeted contaminants. This project investigated a fundamentally new approach for modeling this process that couples thermodynamic descriptions for microbial growth with associated geochemical reactions. In this approach, a synthetic microbial community is defined as a collection of defined microbial groups; each with a growth equation derived from bioenergetic principles. The growth equations and standard-state free energy yields are appended to a thermodynamic database for geochemical reactions and the combined equations are solved simultaneously to predict the effect of added substrates on microbial biomass, community composition, and system geochemistry. This approach, with a single set of thermodynamic parameters (one for each growth equation), was used to predict the results of laboratory and field bioimmobilization experiments at two geochemically diverse research sites. Predicted effects of ethanol or acetate addition on uranium and technetium solubility, major ion geochemistry, mineralogy, microbial biomass and community composition were in general agreement with experimental observations although the available experimental data precluded rigorous model testing. Model simulations provide insight into the long-standing difficulty in transferring experimental results from the laboratory to the field and from one field site to the next, especially if the form, concentration, or delivery of growth substrate is varied from one experiment to the next. Although originally developed for use in better understanding bioimmobilization of uranium and technetium via reductive precipitation, the

  1. THE INVESTIGATION OF BRUCELLA ANTIBODY WITH MILK RING TEST AND AGGLUTINATION TEST IN MILK COLLECTED FROM SAMSUN REGION

    Directory of Open Access Journals (Sweden)

    Goknur TERZI

    2006-06-01

    Full Text Available In this study Brucella antibodies were investigated with agglutination test (Whey-AT and Milk Ring Test (MRT in a total of 100 milk samples as 50 of cow milk and 50 of goat milk collected from center and villages of Samsun. According to MRT Brucella antibodies was positive at 10 samples (20 % of cow milk and 6 samples (12 % of goat milk. In cow milk, 4 (8 % positive, 3 (6 % suspicious and 43 (86 % negative samples; in goat milk 3 (6 % positive, 2 (4 % suspicious and 45 (90 % negative samples were determined according to antibodies titre of serum agglutination test (Whey-AT. [TAF Prev Med Bull 2006; 5(3.000: 196-203

  2. Production of 95mTc with proton bombardment of 95Mo

    International Nuclear Information System (INIS)

    Izumo, M.; Matsuoka, H.; Sorita, T.; Nagame, Y.; Sekine, T.; Hata, K.; Baba, S.

    1991-01-01

    Formation cross sections of 95m Tc and 95g Tc via the 95 Mo (p,n) reaction have been measured to evaluate the production yield of 95m Tc which is expected to be a useful radiotracer of technetium isotopes. It was found from the cross section data that for incident proton energies above 15 MeV, the thick-target yield of 95m Tc was more than 20 μCi/μAh at the end of bombardment and the 95g Tc contamination was less than 1% after 12 d cooling. To examine the separation and purification of 95m Tc from target, we have carried out a test production of 95m Tc using a thick 95 Mo-enriched target. Other reactions of producing 95m Tc are compared and discussed in terms of the production yield and amounts of contaminants. (author)

  3. Experimental study on the usefulness of magnetotherapy in bone fractures (tibial osteotomy in the rat). Accumulation of 99 mTc MDP - tests of tensile strength - determination of alkaline phosphatase

    International Nuclear Information System (INIS)

    Sailer, R.

    1985-01-01

    Non-directional magnetic field therapy using a flux density of 60 G and a frequency of 25 Hz was carried out over 12 hours daily in rats in order to ascertain its influence on the healing process following osteotomy of the tibia with internal splint fixation of the fractured bone being carried out as an additional measure. The results thus achieved were compared to those seen in control animals, were no magnetotherapy was carried out, on the basis of scintiscan studies using 99 mTc MDP (degree of density in the callus formed around the fracture zone), the plasma levels of alkaline phosphatase and tests of tensile strength. The follow-up observations of the healing process were additionally based on radiological and histological evaluations of the animals. Beneficial effects of magnetotherapy on the healing process could not be confirmed with any statistical significance. (TRV) [de

  4. Breast-milk radioactivity after a Tc-99m DTPA aerosol/Tc-99m MAA lung study

    International Nuclear Information System (INIS)

    Mountford, P.J.; Hall, F.M.; Wells, C.P.; Coakley, A.J.

    1984-01-01

    Measurements were made of the concentration of Tc-99m activity in samples of breast milk following an administration of Tc-99m DTPA aerosol for a lung ventilation image and one of Tc-99m MAA for lung perfusion. The activity was 222 nCi/ml of milk (8.2 kBq/ml) at 2 hr after the MAA injection, and it was found to be excreted exponentially with an effective half-life of 4.6 hr. There was a small incorporation of Tc-99m into breast-milk protein. The authors conclude that the combined use of these two Tc-99m agents did not indicate the interruption of breast feeding beyond 24 hr after administration of the MAA, and that for an aerosol ventiliation study alone, breast feeding need not be interrupted for more than 4 hr after the test

  5. Concentration of 99Tc in edible seaweed (Konbu) in the northern part of Japan

    International Nuclear Information System (INIS)

    Ohtsuka, Yoshihito; Iyogi, Takashi; Kakiuchi, Hideki; Hisamatsu, Shun'ichi; Inaba, Jiro

    2006-01-01

    The first commercial nuclear fuel reprocessing plant in Japan is located in Rokkasho Village, Aomori Prefecture, and is now performing uranium testing. We surveyed the distribution of background environmental radiation and radioactive materials around the plant before its full operation and studied causes of their fluctuation. The 99 Tc concentrations of edible seaweed (Konbu) collected in the northern part of Japan are reported here. Since the plant will release small amounts of 99 Tc to the ocean, the concentration of 99 Tc in seawater near the plant might possibly increase in the future. Seaweeds are important food items in Japan, and concentrate some radionuclides in seawater. Therefore, the 99 Tc concentrations in edible seaweeds before the full plant's operation are important to investigate the effect of the plant on the local environmental radioactivity. However, there are few reports of concentrations in edible seaweeds in the world, including those of Japan. Because concentrations of this nuclide in a general environmental sample are extremely low, it is difficult to determine them using conventional radioanalytical techniques. In this study, Tc in a sample was simply and rapidly separated from matrix elements by a solid phase chromatographic resin and an anion exchange resin, successively. The nuclide was determined using an inductively coupled plasma mass spectrometer. Radioactivity of 137 Cs in the sample was also measured by using gamma-ray spectrometry. In 2004, fishing industry cooperative associations of Aomori, Iwate and Hokkaido provided 15 edible seaweed (Konbu) samples, 11 Laminaria japonica and one each of L. ochotensis, L. angustata L. diabolica and L. longissima. Concentrations of 99 Tc in L. japonica ranged from 3.9 to 74 mBq kg -1 -dry, and mean value was 31 mBq kg -1 -dry. Concentrations in other edible seaweeds in Hokkaido were 3.4 - 6.2 mBq kg -1 -dry, except for L. longissima, which was lower than the detection limit (2.4 mBq kg -1 -dry

  6. Impurities in Tc-99m radiopharmaceutical solution obtained from Mo-100 in cyclotron.

    Science.gov (United States)

    Tymiński, Zbigniew; Saganowski, Paweł; Kołakowska, Ewa; Listkowska, Anna; Ziemek, Tomasz; Cacko, Daniel; Dziel, Tomasz

    2018-04-01

    The gamma emitting impurities in 99m Tc solution obtained from enriched molybdenum 100 Mo metallic target after its irradiation in a cyclotron were measured using a high-purity germanium (HPGe) detector. The radioactivity range of tested samples of 99m Tc was rather low, in the range from 0.34 to 2.39 MBq, thus creating a challenge to investigate the standard measurement HPGe system for impurity detection and quantification. In the process of 99m Tc separation from irradiated target the AnaLig® Tc-02 resin, Dionex H + and Alumina A columns were used. Fractions of eluates from various steps of separation process were taken and measured for radionuclidic purity. The overall measurement sensitivity of gamma emitters in terms of minimum detectable activity (MDA) was found at the level of 14-70Bq with emission lines in range of 36 - 1836keV resulting in impurity content range of 6.7 × 10 -4 to 3.4 × 10 -3 % for 93 Tc, 93m Tc, 94 Tc, 94m Tc, 95 Tc, 95m Tc, 96 Tc 96 Nb, 97 Nb, 99 Mo contaminants and 9.4 × 10 -3 % for 97m Tc. The usefulness of the chosen measurement conditions and the method applied to testing the potential contaminators was proved by reaching satisfactory results of MDAs less than the criteria of impurity concentration of all nuclides specified in the European Pharmacopoeia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Vertical distributions of (99)Tc and the (99)Tc/(137)Cs activity ratio in the coastal water off Aomori, Japan.

    Science.gov (United States)

    Nakanishi, Takahiro; Zheng, Jian; Aono, Tatsuo; Yamada, Masatoshi; Kusakabe, Masashi

    2011-08-01

    Using a sector-field ICP-MS the vertical distributions of the (99)Tc concentration and (99)Tc/(137)Cs activity ratio were measured in the coastal waters off Aomori Prefecture, Japan, where a spent-nuclear-fuel reprocessing plant has begun test operation. The (99)Tc concentrations in surface water ranged from 1.8 to 2.4 mBq/m(3), no greater than the estimated background level. Relatively high (99)Tc/(137)Cs activity ratios (10-12 × 10(-4)) would be caused by the inflow of the high-(99)Tc/(137)Cs water mass from the Japan Sea. There is no observable contamination from the reprocessing plant in the investigated area. The (99)Tc concentration and the (99)Tc/(137)Cs activity ratio in water column showed gradual decreases with depth. Our results implied that (99)Tc behaves in a more conservative manner than (137)Cs in marine environments. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Assessment of peritoneal membrane permeability by Tc-99m-excretion in patients undergoing CAPD

    International Nuclear Information System (INIS)

    Das, B.K.; Senthilnathan, M.S.; Pradhan, P.K.; Jeloka, T.K.; Sharma, R.K.

    2002-01-01

    Full text: Among various conservative treatment modalities for end stage renal disease (ESRD), continuous ambulatory peritoneal dialysis (CAPD) is increasingly being used in many centers. The success of CAPD depends largely on the permeable characteristics of the peritoneal membrane. Peritoneal Equilibration Test (PET), first described by Twardowski in 1987, is the most commonly used method for determination of peritoneal membrane characteristics. However, this test has several limitations. In order to find an alternative method for assessing peritoneal membrane characteristics we undertook this prospective study involving 20 patients. The main objective was to determine whether peritoneal excretion of intravenously applied Tc-99m-DTPA can be used for this purpose. 20 patients undergoing regular CAPD were included in this study. 370 MBq (10 mCi) of Tc-99m-DTPA was injected intravenously in the same standard preconditions as for the PET evaluation. A standard dose of 370 MBq (10 mCi) DTPA was kept and used later for calculations. At the end of 4 hours, a dialysate fluid sample was collected and the total dialysis effluent volume was measured. Excretion of Tc-99m-DTPA into the dialysate fluid as percentage of injected dose was calculated. Simultaneously standard PET values were determined. The peritoneal excretion of Tc-99m-DTPA ranged from 8 to 16 % of the injected dose depending upon the peritoneal membrane permeability. The patients were divided into following four groups depending upon DTPA excretion. High transporters (15 % and above); high average(12-15 %); low average (10-12 %); low transporters (10 % and less). When the results were compared with standard PET values, a good correlation could be established. We conclude that the radioisotope method using Tc-99m-DTPA can a good alternative technique to assess peritoneal membrane permeability. (author)

  9. Acceptability of self-collected versus provider-collected sampling for HPV DNA testing among women in rural El Salvador.

    Science.gov (United States)

    Rosenbaum, Alan J; Gage, Julia C; Alfaro, Karla M; Ditzian, Lauren R; Maza, Mauricio; Scarinci, Isabel C; Felix, Juan C; Castle, Philip E; Villalta, Sofia; Miranda, Esmeralda; Cremer, Miriam L

    2014-08-01

    To determine the acceptability of self-collected versus provider-collected sampling among women participating in public sector HPV-based cervical cancer screening in El Salvador. Two thousand women aged 30-49 years underwent self-collected and provider-collected sampling with careHPV between October 2012 and March 2013 (Qiagen, Gaithersburg, MD, USA). After sample collection, a random sample of women (n=518) were asked about their experience. Participants were questioned regarding sampling method preference, previous cervical cancer screening, HPV and cervical cancer knowledge, HPV risk factors, and demographic information. All 518 women approached to participate in this questionnaire study agreed and were enrolled, 27.8% (142 of 511 responding) of whom had not received cervical cancer screening within the past 3 years and were considered under-screened. Overall, 38.8% (n=201) preferred self-collection and 31.9% (n=165) preferred provider collection. Self-collection preference was associated with prior tubal ligation, HPV knowledge, future self-sampling preference, and future home-screening preference (P<0.05). Reasons for self-collection preference included privacy/embarrassment, ease, and less pain; reasons cited for provider-collection preference were result accuracy and provider knowledge/experience. Self-sampling was found to be acceptable, therefore screening programs could consider offering this option either in the clinic or at home. Self-sampling at home may increase coverage in low-resource countries and reduce the burden that screening places upon clinical infrastructure. Copyright © 2014 International Federation of Gynecology and Obstetrics. All rights reserved.

  10. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958

    Energy Technology Data Exchange (ETDEWEB)

    Anspaugh, L.R.; Church, B.W.

    1985-12-01

    In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ''estimated exposure,'' and ''one year effective biological exposure'' are explained. 4 figs., 7 tabs.

  11. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Church, B.W.

    1986-01-01

    In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, UT; Ely, NV; and Las Vegas, NV. Three events, HARRY (19 May 1953), BEE (22 March 1955), and SMOKY (31 August 1957), accounted for more than half the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of infinite exposure, estimated exposure, and 1-yr effective biological exposure are explained

  12. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Church, B.W.

    1985-12-01

    In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ''estimated exposure,'' and ''one year effective biological exposure'' are explained. 4 figs., 7 tabs

  13. Science Library of Test Items. Volume Twenty-One. A Collection of Multiple Choice Test Items Relating Mainly to Physics, 2.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  14. Reliability data collection on IC and VLSI devices tested under accelerated life conditions

    International Nuclear Information System (INIS)

    Barry, D.M.; Meniconi, M.

    1986-01-01

    As part of a more general investigation into the reliability and failure causes of semiconductor devices, statistical samples of integrated circuit devices (LM741C) and dynamic random access memory devices (TMS4116) were tested destructively to failure using elevated temperature as the accelerating stress. The devices were operated during the life test and the failure data generated were collected automatically using a multiple question-and-answer program and a process control computer. The failure data were modelled from the lognormal, inverse Gaussian and Weibull distribution using an Arrhenius reaction rate model. The failed devices were later decapsulated for failure cause determination. (orig./DG)

  15. Test Operations Procedure (TOP) 1-1-062 Environmental Effects Data Collection

    Science.gov (United States)

    2008-09-12

    this procedure. 11. ESTIMATION DESCRIPTION The prime example of an empirically based model is the Universal Soil Loss Equation ( USLE ) developed...impacts to human health and welfare and to the natural environment. The type of data collected might include noise levels, soil erosion, and...uptake relevant to flora/fauna and the soil erosion effects of proposed testing. c. Plan to identify any modifications/alternatives implemented

  16. Pretreatment of Tc-Containing Waste and Its Effect on Tc-99 Leaching From Grouts

    International Nuclear Information System (INIS)

    Aloy, Albert; Kovarskaya, Elena N.; Harbour, John R.; Langton, Christine A.; Holtzscheiter, E. William

    2007-01-01

    A salt solution (doped with Tc-99), that simulates the salt waste stream to be processed at the Saltstone Production Facility, was immobilized in grout waste forms with and without (1) ground granulated blast furnace slag and (2) pretreatment with iron salts. The degree of immobilization of Tc-99 was measured through monolithic and crushed grout leaching tests. Although Fe (+2) was shown to be effective in reducing Tc-99 to the +4 state, the strong reducing nature of the blast furnace slag present in the grout formulation dominated the reduction of Tc-99 in the cured grouts. An effective diffusion coefficient of 4.75 x 10 -12 (Leach Index of 11.4) was measured using the ANSI/ANS-16.1 protocol. The leaching results show that, even in the presence of a concentrated salt solution, blast furnace slag can effectively reduce pertechnetate to the immobile +4 oxidation state. The measured diffusivity was introduced into a flow and transport model (PORFLOW) to calculate the release of Tc-99 from a Saltstone Vault as a function of hydraulic conductivity of the matrix. (authors)

  17. Contribution of {sup 99m}Tc-DTPA dynamic renal scintigraphy with furosemide test in the exploration of low grade urethra-pelvic junction syndrome. Report of 17 cases; Apport de la scintigraphie renale dynamique au {sup 99m}Tc-DTPA avec epreuve au furosemide dans l'exploration du syndrome de la jonction pyelo-uretrale a minima. A propos de 17 cas

    Energy Technology Data Exchange (ETDEWEB)

    Ghfir, I.; Ben Rais, N. [Hopital Ibn Sina, CHU de Rabat, Service de Medecine Nucleaire, Rabat (Morocco)

    2009-10-15

    Introduction The renal scintigraphy using {sup 99m}Tc-DTPA with furosemide test constitutes a noninvasive and functional method that is of appreciable interest in the exploration of the upper urinary tract and in the evaluation of the separate renal function. It distinguishes the functional character of dilation from organic obstruction needing surgery or endoscopic treatment. Material and methods We report, through this work, the observations of 17 patients with a low grade urethra-pelvic junction syndrome detect by intravenous urography (I.V.U.). {sup 99m}Tc-DTPA renal scintigraphy with furosemide test was carried out among all our patients by means of a gamma-camera with large field equipped with a low energy high-resolution parallel collimator. The evaluation of images obtained consisted of analysis of urethra-pelvic permeability taking into account the semiquantitative parameters of time-activity curve or isotopic nephrogram (I.N.) obtained after digital reconstruction of sequential images. Results On the 17 studied cases, the sex-ratio was equal to 1.83; the average age was 18.92 years with extremes spanning from 4 years to 70 years. Renal scintigraphy categorized four patients groups. Group I: two patients (11.76%) with normal aspect of I.N.; group II; seven patients (41.17% of cases) with functional dilation; group III: five patients (29.41%) with organic obstruction and a group IV: three patients (17.64%) with intermediate response. Discussion {sup 99m}Tc-DTPA renal scintigraphy with furosemide test allowed, through our study, to obviate the limits of IVU and manometric explorations to distinguish functional dilation of organic obstruction. It permits the improvement of treatment with a favourable dosimetry. (authors)

  18. Superplastic Deformation of TC6 Alloy

    Directory of Open Access Journals (Sweden)

    DING Ling

    2016-12-01

    Full Text Available The superplastic tensile tests of TC6 alloy were conducted in the temperature range of 800-900℃ by using the maximum m value superplasticity deformation (Max m SPD method and the constant strain rate deformation method at the strain rate range of 0.0001-0.1 s-1. The stress-strain curve of the tensile tests was obtained and the microstructure near the fracture were analyzed by metallographic microscope. The result shows that the superplasticity of TC6 alloy is excellent, and the elongation increases first and then decreases with the increase of strain rate or temperature. When the temperature is 850℃ and strain rate is 0.001 s-1 at constant stain rate tensile tests, the elongation reaches up to 993%. However, the elongation using Max m SPD method at 850℃ is 1353%. It is shown that the material can achieve better superplasticity by using Max m SPD tensile compared to constant stain rate tensile under the same temperature. The superplastic deformation of TC6 alloy can enhance the dynamic recrystallization behavior significantly, the dynamic recrystallization behavior is promoted when strain rate and temperature are increased.

  19. Cryogenic and Gas System Piping Pressure Tests (A Collection of PT Permits)

    International Nuclear Information System (INIS)

    Rucinski, Russell A.

    2002-01-01

    This engineering note is a collection of pipe pressure testing documents for various sections of piping for the D-Zero cryogenic and gas systems. High pressure piping must conform with FESHM chapter 5031.1. Piping lines with ratings greater than 150 psig have a pressure test done before the line is put into service. These tests require the use of pressure testing permits. It is my intent that all pressure piping over which my group has responsibility conforms to the chapter. This includes the liquid argon and liquid helium and liquid nitrogen cryogenic systems. It also includes the high pressure air system, and the high pressure gas piping of the WAMUS and MDT gas systems. This is not an all inclusive compilation of test documentation. Some piping tests have their own engineering note. Other piping section test permits are included in separate safety review documents. So if it isn't here, that doesn't mean that it wasn't tested. D-Zero has a back up air supply system to add reliability to air compressor systems. The system includes high pressure piping which requires a review per FESHM 5031.1. The core system consists of a pressurized tube trailer, supply piping into the building and a pressure reducing regulator tied into the air compressor system discharge piping. Air flows from the trailer if the air compressor discharge pressure drops below the regulator setting. The tube trailer is periodically pumped back up to approximately 2000 psig. A high pressure compressor housed in one of the exterior buildings is used for that purpose. The system was previously documented, tested and reviewed for Run I, except for the recent addition of piping to and from the high pressure compressor. The following documents are provided for review of the system: (1) Instrument air flow schematic, drg. 3740.000-ME-273995 rev. H; (2) Component list for air system; (3) Pressure testing permit for high pressure piping; (4) Documentation from Run I contained in D-Zero Engineering note

  20. A comparison of human papillomavirus testing of clinician-collected and self-collected samples during follow-up after screen-and-treat.

    Science.gov (United States)

    Taylor, Sylvia; Wang, Chunhui; Wright, Thomas C; Denny, Lynette; Kuhn, Louise

    2011-08-15

    Screen-and-treat cervical cancer prevention programs based on high-risk human papillomavirus (HPV) testing and cryotherapy have been shown to be effective in resource-limited settings. However, because cryotherapy is not 100% effective, follow-up is needed after treatment to detect post-treatment failures. We compared the test performances of high-risk HPV testing (Hybrid Capture 2) using self-collected and clinician-collected samples as well as cervical cytology for identifying cervical intraepithelial neoplasia grades 2 or 3 or invasive cervical cancer (CIN2+) among women who did (n=812) and did not (n=1858) undergo cryotherapy in a South African screen-and-treat trial. At 6 months after enrolment (and after cryotherapy, if performed), women were tested using all three screening methods and then underwent colposcopy/biopsy. A predefined subset of women (n=1,455) had extended follow-up with colposcopy/biopsy at 12 months. A total of 33 and 91 cases of CIN2+ were detected among treated and untreated women, respectively. The sensitivity of HPV testing using clinician-collected samples and cervical cytology did not differ by treatment status. HPV testing of clinician-collected samples detected the most cases of CIN2+ among both treated (85%) and untreated (91%) women (p=0.31). Cytology (at a cutoff of atypical squamous cells of undetermined significance or greater) detected 76% of cases among both treated and untreated women. However, the sensitivity of HPV testing using self-collected samples was significantly lower among treated versus untreated women (55% vs. 78%, p=0.01). HPV testing using self-collected vaginal specimens may be useful in primary screening but performs poorly for detecting post-treatment failures. Copyright © 2010 UICC.

  1. Evaluation and investigation of regional cerebral blood flow by 1 point arterial blood collection method using 99mTc-ECD. Intravenous injection for 4 minutes with constant speed

    International Nuclear Information System (INIS)

    Itoh, Takeo; Shibata, Kazuhiro; Sudoh, Hideaki; Tanaka, Masato; Itoh, Kenjiro; Ueno, Yasushi

    1998-01-01

    Regional cerebral blood flow (rCBF) was measured using a 99m Tc-ECD through the 4-min constant intravenous infusion/one point arterial blood sampling method, proposed by Nakagawara et al. of Nakamura Memorial Hospital, and 133Xenon ( 133 Xe)-SPECT was performed on the same subjects to investigate the reproducibility of this method. We also determined whether cerebral blood flow (CBF) could be measured on the day of blood sampling through dilution of the obtained blood because it was difficult to measure the radioactivity in the blood on the day of blood sampling by this method. More, we investigated fixation of an octanol extraction rate and the substitution of venous blood for arterial blood in this method. The results revealed that CBF measured by this method with a 99m Tc-ECD were closely correlated to those measured by 133 Xe-SPECT, indicating the reliability as a method of measuring CBF. rCBF could be measured on the day of blood sampling through appropriate dilution of the obtained arterial blood. Octanol extraction rates were almost constant, indicating possible omission of cumbersome extraction procedure by fixation. However, the substitution of venous blood for arterial blood showed no correlation under the study system examined. (author)

  2. Beta Testing StraboSpot: Perspectives on mobile field mapping and data collection

    Science.gov (United States)

    Bunse, E.; Graham, K. A.; Rufledt, C.; Walker, J. D.; Müller, A.; Tikoff, B.

    2017-12-01

    Geologic field mapping has recently transitioned away from traditional techniques (e.g. field notebooks, paper mapping, Brunton compasses) and towards mobile `app' mapping technology. The StraboSpot system (Strabo) is an open-source solution for collection and storage for geologic field, microstructural, and lab-based data. Strabo's mission is to "enable recording and sharing data within the geoscience community, encourage interdisciplinary research, and facilitate the investigation of scientific questions that cannot currently be addressed" (Walker et al., 2015). Several mobile application beta tests of the system, on both Android and Apple iOS platforms using smartphones and tablets, began in Summer 2016. Students at the 2016 and 2017 University of Kansas Field Camps used Strabo in place of ArcGIS for Desktop on Panasonic Toughbooks, to field map two study areas. Strabo was also field tested by students of graduate and undergraduate level for both geo/thermochronologic sample collection and reconnaissance mapping associated with regional tectonic analysis in California. Throughout this period of testing, the app was geared toward structural and tectonic geologic data collection, but is versatile enough for other communities to currently use and is expanding to accommodate the sedimentology and petrology communities. Overall, users in each of the beta tests acclimated quickly to using Strabo for field data collection. Some key advantages to using Strabo over traditional mapping methods are: (1) Strabo allows for consolidation of materials in the field; (2) helps students track their position in the field with integrated GPS; and (3) Strabo data is in a uniform format making it simple for geologists to collaborate. While traditional field methods are not likely to go out of style in the near future, Strabo acts as a bridge between professional and novice geologists by providing a tool that is intuitive on all levels of geological and technological experience and

  3. Preliminary clinical study in patients with hemispatial neglect after stroke by neglect test battery and 99mTc-ECD single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yin Yafu; Li Xuena; Li Yaming; Gu Hui; Han Chunqi; Liu Hao

    2009-01-01

    Objective: To explore the presence, clinical characteristics, anatomical foci in image and mechanism of hemispatial neglect (HSN), neglect test battery and single-photon emission computed tomography (SPECT) regional cerebral blood flow (rCBF) imaging were performed on patients with stroke. Methods: Thirty dextromanual patients who were diagnosed as having unilateral stroke clinically were recruited. A neglect test battery including line bisection test, star cancellation test and drawing test was performed on the subjects. The severity of neglect was measured on neglect tests. The lowest rCBF, the range with decreased rCBF, number of the foci with decreased rCBF, the flow deficit size and the total number of pixels in the foci were measured on SPECT rCBF imaging. Results: Twenty-five patients were diagnosed as having HSN by the neglect test battery. Contralateral neglect (CN) and ipsilateral neglect (IN) were observed in both right and left hemisphere strokes. On SPECT imaging, the patients with neglect had decreased rCBF in the frontal cortex most often; followed by the parietal, occipital and temporal cortices; and basal ganglia and thalamus in some cases. The patients who had two or more regions damaged showed neglect more often and severity. The correlation coefficients between rCBF in the foci, the decreased percentage of rCBF of the foci and the severity of neglect were -0.119 (P>.05) and 0.221 (P>.05). The correlation coefficients between the range, number of foci, the flow deficit size, the total number of pixels of the foci and the severity of neglect were 0.537 (P<.05), 0.493 (P<.05), 0.561 (P<.05), 0.466 (P<.05), respectively. No difference between CN and IN on SPECT images reached statistical significance. Conclusions: The severity of neglect did not correlate with rCBF and the decreased percentage of rCBF in the foci, while it was significantly correlated with the range, number of foci, the flow deficit size and the total numbers of pixels of the foci

  4. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  5. Treatment with radioisotopes (RI), (40). A discussion of a morphological diagnosis and a diagnosis of cell function in the liver with sup(99m)Tc-HIDA (sup(99m)Tc-PI) and sup(99m)Tc-phytate

    Energy Technology Data Exchange (ETDEWEB)

    Asahara, A [Central Hospital of JNR, Tokyo (Japan)

    1978-11-01

    sup(99m)Tc-N-N-(N'(2,6 dimethylphenyl) carbamoyl methyl) iminodiacetic acid (sup(99m)Tc-HIDA) or sup(99m)Tc-phytate was administered to the same case, and their uptake into the liver was discussed by hepatic scintigraphy and hepatogram. As a result, hepatic images of subjects with normal liver function and those with cholelithiasis whose biliary flow was normal were the same, and there was no difference in a morphological diagnosis between them. Sufficient images could not be obtained because sup(99m)Tc-HIDA uptake into the liver decreased in acute hepatitis and acute obstructive jaundice, but sufficient images could be obtained by using sup(99m)Tc-phytate and its uptake into the liver was normal. The uptake of both agents decreased in most of the subjects with liver cirrhosis. As a collective result of both agents, various specific patterns of their uptake were showed according to diseases. sup(99m)Tc-phytate is more useful when an examination is made only to take hepatic image, because this agent is less limit for hepatic imaging. Uptake of sup(99m)Tc-HIDA and sup(99m)Tc-phytate into the liver and their excretion were almost the same in most of diseases, and there was no difference in diagnostic application merits between them. Excretion rate of sup(99m)Tc-HIDA was very low in Dubin-Johnson syndrome, but that of sup(99m)Tc-pyridoxylidene isoleusin (PI) was almost normal. It was supposed that metabolism of sup(99m)Tc-HIDA in hepatic cells differs from that of sup(99m)Tc-PI. (Tsunoda, M.).

  6. Does interaction matter? Testing whether a confidence heuristic can replace interaction in collective decision-making.

    Science.gov (United States)

    Bang, Dan; Fusaroli, Riccardo; Tylén, Kristian; Olsen, Karsten; Latham, Peter E; Lau, Jennifer Y F; Roepstorff, Andreas; Rees, Geraint; Frith, Chris D; Bahrami, Bahador

    2014-05-01

    In a range of contexts, individuals arrive at collective decisions by sharing confidence in their judgements. This tendency to evaluate the reliability of information by the confidence with which it is expressed has been termed the 'confidence heuristic'. We tested two ways of implementing the confidence heuristic in the context of a collective perceptual decision-making task: either directly, by opting for the judgement made with higher confidence, or indirectly, by opting for the faster judgement, exploiting an inverse correlation between confidence and reaction time. We found that the success of these heuristics depends on how similar individuals are in terms of the reliability of their judgements and, more importantly, that for dissimilar individuals such heuristics are dramatically inferior to interaction. Interaction allows individuals to alleviate, but not fully resolve, differences in the reliability of their judgements. We discuss the implications of these findings for models of confidence and collective decision-making. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Data collection and analysis software development for rotor dynamics testing in spin laboratory

    Science.gov (United States)

    Abdul-Aziz, Ali; Arble, Daniel; Woike, Mark

    2017-04-01

    Gas turbine engine components undergo high rotational loading another complex environmental conditions. Such operating environment leads these components to experience damages and cracks that can cause catastrophic failure during flights. There are traditional crack detections and health monitoring methodologies currently being used which rely on periodic routine maintenances, nondestructive inspections that often times involve engine and components dis-assemblies. These methods do not also offer adequate information about the faults, especially, if these faults at subsurface or not clearly evident. At NASA Glenn research center, the rotor dynamics laboratory is presently involved in developing newer techniques that are highly dependent on sensor technology to enable health monitoring and prediction of damage and cracks in rotor disks. These approaches are noninvasive and relatively economical. Spin tests are performed using a subscale test article mimicking turbine rotor disk undergoing rotational load. Non-contact instruments such as capacitive and microwave sensors are used to measure the blade tip gap displacement and blade vibrations characteristics in an attempt develop a physics based model to assess/predict the faults in the rotor disk. Data collection is a major component in this experimental-analytical procedure and as a result, an upgrade to an older version of the data acquisition software which is based on LabVIEW program has been implemented to support efficiently running tests and analyze the results. Outcomes obtained from the tests data and related experimental and analytical rotor dynamics modeling including key features of the updated software are presented and discussed.

  8. The Urine Marker Test: An Alternative Approach to Supervised Urine Collection for Doping Control.

    Science.gov (United States)

    Elbe, Anne-Marie; Jensen, Stine Nylansted; Elsborg, Peter; Wetzke, Monika; Woldemariam, Getachew A; Huppertz, Bernd; Keller, Ruprecht; Butch, Anthony W

    2016-01-01

    Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. The objective of this study was to investigate the use of the urine marker during urine doping control testing. Two studies investigated athletes' acceptance of this new method via two questionnaires (n = 253). Furthermore, a third study (n = 91) investigated whether ingestion of the marker can identify the urine as coming from a specific person and whether the marker interferes with the detection of prohibited substances. The results indicate that this new method finds wide acceptance both from athletes who have only heard about the procedure and those who have actually tested the new method. Furthermore, the marker, which can identify urine as coming from a specific person, does not interfere with the detection of prohibited substances.

  9. Coastal California's Fog Aerobiology and Ecology: Designing and Testing an Optimal Passive Impactor Collection Unit

    Science.gov (United States)

    Gentry, D.; Whinnery, J. T.; Ly, V. T.; Travers, S. V.; Sagaga, J.; Dahlgren, R. P.

    2017-12-01

    Microorganisms play a major role in our biosphere due to their ability to alter water, carbon and other geochemical cycles. Fog and low-level cloud water can play a major role in dispersing and supporting such microbial diversity. An ideal region to gather these microorganisms for characterization is the central coast of California, where dense fog is common. Fog captured from an unmanned aerial vehicle (UAV) at different altitudes will be analyzed to better understand the nature of microorganisms in the lower atmosphere and their potential geochemical impacts. The capture design consists of a square-meter hydrophobic mesh that hangs from a carbon fiber rod attached to a UAV. The DJI M600, a hexacopter, will be utilized as the transport for the payload, the passive impactor collection unit (PICU). The M600 will hover in a fog bank at altitudes between 10 and 100 m collecting water samples via the PICU. A computational flow dynamics (CFD) model will optimize the PICU's size, shape and placement for maximum capture efficiency and to avoid contamination from the UAV downwash. On board, there will also be an altitude, temperature and barometric pressure sensor whose output is logged to an SD card. A scale model of the PICU has been tested with several different types of hydrophobic meshes in a fog chamber at 90-95% humidity; polypropylene was found to capture the fog droplets most efficiently at a rate of .0042 g/cm2/hour. If the amount collected is proportional to the area of mesh, the estimated amount of water collected under optimal fog and flight conditions by the impactor is 21.3 g. If successful, this work will help identify the organisms living in the lower atmosphere as well as their potential geochemical impacts.

  10. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  11. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. II. Test series after Hardtack II, 1958, and summary

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Ricker, Y.E.; Black, S.C.; Grossman, R.F.; Wheeler, D.L.; Church, B.W.; Quinn, V.E.

    1990-01-01

    The historical data on the cumulative individual external gamma exposures are tabulated for communities around the Nevada Test Site for the time periods of 1961 to the signing of the Limited Test Ban Treaty on 5 August 1963, and from then until 1975. The collective exposures during the two time periods are calculated to be 610 and 320 person-R, respectively. The total collective external gamma exposure from 1951 through 1975 for these communities s calculated to be 86,000 person-R. The area considered includes the countries of Clark, Lincoln, Nye, and White Pine in Nevada and the countries of Iron and Washington in Utah; inclusion of Salt Lake City would have substantially increased the calculated collective exposure because of the large population. The methods of calculation are reviewed. Also, the historical data on the assessment of dose via ingestion are reviewed with emphasis on the dose to the thyroid of infants living in St. George, UT, at the time of fallout from event HARRY on 19 May 1953

  12. Radiopharmacokinetic data for 99mTc-ABP - A new radiopharmaceutical for bone scanning: Comparison with 99mTc-MDP

    International Nuclear Information System (INIS)

    Murphy, Consuelo Arteaga de; Melendez-Alafort, Laura; Montoya-Molina, Carlos E.; Sepulveda-Mendez, Jesus

    1997-01-01

    Technetium-99m-labeled alendronate is a new radiopharmaceutical for bone scanning developed under strict quality control at the INNSZ. The purpose of this work was to compare the radiopharmacokinetic data and the dosimetry of 99m Tc-ABP and 99m Tc-MDP in 10 volunteers, after it was tested in laboratory animals. 99m Tc-ABP has shorter mean residence time (MRT) and t (1(2)) β; is less protein bound; has a higher renal clearance; smaller Vdss, and similar bone uptake at 1 and 2 h. 99m Tc-ABP gives less radiation exposure to the patient with a 740 MBq dose, and the quality of the bone scan is excellent. 99m Tc-ABP is a better radiopharmaceutical than 99m Tc-MDP for bone scanning

  13. Tc: chemistry and radiopharmaceuticals: a prospectus

    International Nuclear Information System (INIS)

    Tulip, T.H.

    1987-01-01

    The recent explosion in technetium chemistry evident in this symposium promises to continue unabated. As in the past, radiopharmaceutical applications will lead to new Tc chemistry. In this lecture the author will discuss those areas which appear most fertile based on chemical and radiopharmaceutical criteria. Among these will be new organometallic Tc chemistry (e.g., Tc(CNR) 6 cations), Tc complexes as metabolic tracers (e.g., Tc-analogs to FDG), and peptide-based Tc chelators (e.g., Tc-metallothionein)

  14. Side-suspended High-Tc Superconducting Maglev Prototype Vehicle Running at a High Speed in an Evacuated Circular Test Track

    Science.gov (United States)

    Zhou, Dajin; Zhao, Lifeng; Cui, Chenyu; Zhang, Yong; Guo, Jianqiang; Zhao, Yong

    2017-07-01

    High-T c superconductor (HTS) and permanent magnetic guideway (PMG) based maglev train is intensively studied in China, Japan, Germany and Brazil, mainly through static or vibration test. Amongst these studies, only a few of reports are available for the direct and effective assessment on the dynamic performance of the HTS maglev vehicle by running on a straight or circular PMG track. The highest running speed of these experiments is lower than 50 km/h. In this paper, a side-suspended HTS permanent magnetic guideway maglev system was proposed and constructed in order to increase the running speed in a circular track. By optimizing the arrangement of YBCO bulks besides the PMG, the side-suspended HTS maglev prototype vehicle was successfully running stably at a speed as high as 150 km/h in a circular test track with 6.5 m in diameter, and in an evacuated tube environment, in which the pressure is 5 × 103 Pa.

  15. Development and testing of a two stage granular filter to improve collection efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Rangan, R.S.; Prakash, S.G.; Chakravarti, S.; Rao, S.R.

    1999-07-01

    A circulating bed granular filter (CBGF) with a single filtration stage was tested with a PFB combustor in the Coal Research Facility of BHEL R and D in Hyderabad during the years 1993--95. Filter outlet dust loading varied between 20--50 mg/Nm{sup 3} for an inlet dust loading of 5--8 gms/Nm{sup 3}. The results were reported in Fluidized Bed Combustion-Volume 2, ASME 1995. Though the outlet consists of predominantly fine particulates below 2 microns, it is still beyond present day gas turbine specifications for particulate concentration. In order to enhance the collection efficiency, a two-stage granular filtration concept was evolved, wherein the filter depth is divided between two stages, accommodated in two separate vertically mounted units. The design also incorporates BHEL's scale-up concept of multiple parallel stages. The two-stage concept minimizes reentrainment of captured dust by providing clean granules in the upper stage, from where gases finally exit the filter. The design ensures that dusty gases come in contact with granules having a higher dust concentration at the bottom of the two-stage unit, where most of the cleaning is completed. A second filtration stage of cleaned granules is provided in the top unit (where the granules are returned to the system after dedusting) minimizing reentrainment. Tests were conducted to determine the optimum granule to dust ratio (G/D ratio) which decides the granule circulation rate required for the desired collection efficiency. The data brings out the importance of pre-separation and the limitation on inlet dust loading for any continuous system of granular filtration. Collection efficiencies obtained were much higher (outlet dust being 3--9 mg/Nm{sub 3}) than in the single stage filter tested earlier for similar dust loading at the inlet. The results indicate that two-stage granular filtration has a high potential for HTHT application with fewer risks as compared to other systems under development.

  16. Migration of 99Tc in a weak loess aquifer. A field column experiment

    International Nuclear Information System (INIS)

    Liu, C.L.; Wang, X.Y.; Wang, H.F.

    2001-01-01

    The migration of 99 Tc in a weak loess aquifer was investigated in-situ with undisturbed aquifer medium columns. The columns were obtained horizontally at a depth of 32∼36 m in an Underground Research Facility (URF). Quartz containing 3 H (HTO) and 99 Tc (in the form of 99 TcO 4 - ) was introduced into one end of the columns and the columns were covered tightly. Aquifer water was introduced into the columns directly from an experimental shaft in the UFR. Effluents from the columns were collected and the activity of 3 H and 99 Tc were determined with a liquid scintillation analyzer. The breakthrough curves of 3 H and 99 Tc indicate that 99 Tc migrates a little faster than that 3 H does in the aquifer. (author)

  17. Batch test equilibration studies examining the removal of Cs, Sr, and Tc from supernatants from ORNL underground storage tanks by selected ion exchangers

    International Nuclear Information System (INIS)

    Collins, J.L.; Egan, B.Z.; Anderson, K.K.; Chase, C.W.; Bell, J.T.

    1995-01-01

    Bench-scale batch equilibration tests have been conducted with supernatants from two underground tanks at the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to determine the effectiveness of selected ion exchangers in removing cesium, strontium, and technetium. Seven sorbents were evaluated for cesium removal, nine for strontium removal, and four for technetium removal. The results indicate that granular potassium cobalt hexacyanoferrate was the most effective of the exchangers evaluated for removing cesium from the supernatants. The powdered forms of sodium titanate (NaTiO) and cystalline silicotitanate (CST) were superior in removing the strontium; however, for the sorbents of suitable particle size for column use, titanium monohydrogen phosphate (TiHP φ), sodium titanate/polyacrylonitrile (NaTiO-PAN), and titanium monohydrogen phosphate/polyacrylonitrile (TiP-PAN) gave the best results and were about equally effective. Reillex trademark 402 was the most effective exchanger in removing the technetium; however, it was only slightly more satisfactory than Reillex trademark HPQ

  18. A new method for 99mTc-labelling of proteins, leucocytes and platelets for nuclear medicine application

    International Nuclear Information System (INIS)

    Sundrehagen, E.

    1984-01-01

    A reduced state of 99mTc was obtained by concentrated hydrocloric acid treatment of the 99mTc(VII)/0.15 M NaCl eluate from 99Mo/99mTc generators. Non-acidic reduced state of 99mTc in dry NaCl deposit was obtained by vacuum evaporation of concentrated HCl and water. A monitored vacuum evaporator built for this purpose is presented, as well as methods of formation of various 99mTc-protein and 99mTc-polypeptide complexes. After careful protein precipation or anionic adsorption of pertechnetate and 99mTc-gentisic acid complexes, high radiochemical purities of labelled proteins were demonstrated by gel chromatography studies, radioimmunological methods, radioaffinity testing studies and ampholyte displacement radiochromatography. Preparative methods for 99mTc-plasmin (at pH=2), 99mTc-secretin (at pH=3) and 99mTc-IgG (at pH=4) are presented. The role and the limitations of 99mTc-plasmin for diagnosis of deep vein thrombosis were investigated in experimentally induced jugular vein thrombosis in rabbits. The in vivo distribution of intravenously injected 99mTc-secretin was found to be in correspondance with that of unlabelled secretin. Labelling of platelets and leucoytes from human blood with 99mTc was carried out at pH=7.2. Data for a remarkable high stability of the labelled cells are presented

  19. High-Tc superconductor applications

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    There has been much speculation about new products and business opportunities which high-Tc superconductors might make possible. However, with the exception of one Japanese survey, there have not been any recognized forecasts suggesting a timeframe and relative economic impact for proposed high-Tc products. The purpose of this survey is to provide definitive projections of the timetable for high-Tc product development, based on the combined forecasts of the leading U.S. superconductivity experts. The FTS panel of experts on high-Tc superconductor applications, representing both business and research, forecast the commercialization and economic impact for 28 classes of electronic, magnetic, communications, instrumentation, transportation, industrial, and power generation products. In most cases, forecasts predict the occurrence of developments within a 90% statistical confidence limit of 2-to-3 years. The report provides background information on the 28 application areas, as well as other information useful for strategic planners. The panel also forecast high-Tc research spending, markets, and international competitiveness, and provide insight into how the industry will evolve

  20. Synthesis and in vivo testing of a bromobutyl substituted 1,2-dithia-5,9-diazacycloundecane: a versatile precursor for new sup 99m Tc-bis(aminoethanethiol) complexes

    Energy Technology Data Exchange (ETDEWEB)

    Eisenhut, M.; Brandau, W.; Missfeldt, M. (Heidelberg Univ. (Germany, F.R.). Radiologisches Zentrum)

    1989-01-01

    7-(4'Bromobutyl)-3,3,11,11-tetramethyl-1,2-dithia-5,9-diazacycloundecane (6) an intermediate for the preparation of new {sup 99m}Tc-bis(aminoethanethiol) complexes ({sup 99m}Tc-BAT) was synthesized from the corresponding 7-(4'-phenoxybutyl) derivative (5) by ether cleavage with HBr/AcOH. To demonstrate its versatility as an alkylating agent, 6 was reacted with the amines piperidine, morpholine, NH{sub 3} and 1-phenyl-1,3,8-triazaspiro(4,5)decan-4-one, yielding the corresponding N-alkylated amines. Mild ring opening affording the BAT-ligands was achieved by reductive cleavage of the disulphide bonds with threo-2,3-dihydroxy-1,4-dimercaptobutane. The {sup 99m}Tc-BAT complexes prepared by the tin-reduction method proved to be stable under in vitro conditions. With the exception of the 7-(4'-aminobutyl) substituted one, the {sup 99m}Tc-BAT complexes revealed octanol-buffer partition coefficients (P) of log P > 1 at physiological pH. The complexes proved to be neutral and the amount of ultrafiltrable {sup 99m}Tc-BAT complex varied between 8-18%. In contrast to the good in vitro characteristics, the brain uptake values in CD-1 mice were comparably low. (author).

  1. Tigecycline activity tested against 26,474 bloodstream infection isolates: a collection from 6 continents.

    Science.gov (United States)

    Sader, Helio S; Jones, Ronald N; Stilwell, Matthew G; Dowzicky, Michael J; Fritsche, Thomas R

    2005-07-01

    The activity of tigecycline (formerly GAR936), a novel glycylcycline, was tested against recent bloodstream infection (BSI) pathogen isolates from 6 continents. Frequency of clinical occurrence of these pathogens was determined and their antibiograms assessed using reference broth microdilution methods. A total of 26474 strains were tested for tigecycline susceptibility according to the Clinical and Laboratory Standards Institute (formerly the National Committee for Clinical Laboratory Standards) by the M7-A6 guidelines with interpretations from M100-S15 and the package insert. The rank order of pathogens was Staphylococcus aureus (33.1%), Escherichia coli (14.0%), coagulase-negative staphylococci (13.5%), Enterococcus spp. (12.3%), Klebsiella spp. (5.7%), Pseudomonas aeruginosa (4.2%), Enterobacter spp. (3.0%), beta-hemolytic streptococci (2.9%), Streptococcus pneumoniae (2.3%), and viridans group streptococci (1.4%). Tigecycline exhibited a broader spectrum of activity against BSI isolates when compared to ciprofloxacin, tetracycline, aminoglycosides, and many beta-lactams (imipenem). Tigecycline was highly active against most pathogens tested, including staphylococci (MIC(90), 0.5 microg/mL), enterococci (MIC90, 0.25 microg/mL), streptococci (MIC(90), < or =0.12 microg/mL), Escherichia coli (MIC90, 0.25 microg/mL), Klebsiella spp. (MIC90, 1 mmicrog/mL), and Enterobacter spp. (MIC(90), 2 mmicrog/mL), but showed limited inhibition of Pseudomonas aeruginosa (MIC90, 16 microg/mL) and indole-positive or indole-negative Proteae (MIC90, 4-8 microg/mL). In summary, tigecycline exhibited a wide spectrum of antimicrobial potency versus BSI isolates collected worldwide. Serious infections in nosocomial environments should benefit from tigecycline use among the investigational phase 3 agents focused toward resistant strains.

  2. Texas flexible pavements and overlays : year 1 report, test sections, data collection, analyses, and data storage system.

    Science.gov (United States)

    2012-06-01

    This five-year project was initiated to collect materials and pavement performance data on a minimum of 100 highway test sections around the State of Texas, incorporating both flexible pavements and overlays. Besides being used to calibrate and valid...

  3. A new test procedure to evaluate the performance of substations for collective heating systems

    Science.gov (United States)

    Baetens, Robin; Verhaert, Ivan

    2017-11-01

    The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  4. A new test procedure to evaluate the performance of substations for collective heating systems

    Directory of Open Access Journals (Sweden)

    Baetens Robin

    2017-01-01

    Full Text Available The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  5. Acting in solidarity : Testing an extended dual pathway model of collective action by bystander group members

    NARCIS (Netherlands)

    Saab, Rim; Tausch, Nicole; Spears, Russell; Cheung, Wing-Yee

    We examined predictors of collective action among bystander group members in solidarity with a disadvantaged group by extending the dual pathway model of collective action, which proposes one efficacy-based and one emotion-based path to collective action (Van Zomeren, Spears, Fischer, & Leach,

  6. A modified method for the in vivo labeling of red blood cells with /sup 99m/Tc: concise communication

    International Nuclear Information System (INIS)

    Callahan, R.J.; Froelich, J.W.; McKusick, K.A.; Leppo, J.; Strauss, H.W.

    1982-01-01

    The rate of incorporation of /sup 99m/Tc into red blood cells pretinned in vivo was measured by collecting blood samples in stannous DTPA solution, which served as a competing ligand for /sup 99m/Tc. This collection technique permitted a measurement of high-affinity red-cell labeling efficiency at the instant of sampling. At 0.5 min after injection only 62% of technetium is tightly bound to the red cell; this rises to 94.5% at 10 min. Based on the graded labeling of the red cells, the in vivo labeling procedure was modified by isolating pertechnetate and red blood cells tinned in vivo in a syringe during the first 10 min of labeling. The pertechnetate is thus prevented from distributing to extravascular compartments, and 90% of the injected /sup 99m/Tc is firmly bound to red blood cells at the time of injection. In a series of 23 patients, seven were tested with the in vivo method and seven with the modified in vivo method, and nine patients were tested with each method on separate occasions. A decrease in gastric activity and improved image quality were found with the modified method compared with the standard method of in vivo red-cell labeling

  7. Study on the metabolic peculiarities of renal radiotracer 99mTc-PAHIDA and diagnostic use

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Wang Liuyi; Lun Mingyue

    1994-11-01

    The metabolic peculiarities of renal radiotracer 99m Tc-PAHIDA and diagnostic use were studied. The results of the radioactive tracing study showed that 99m Tc-PAHIDA was distributed predominantly in kidney, and then in heart, gastrointestinal tract, liver, spleen, musculus quadriceps femoris, adipose tissue, testes and brain. It should be noted that when smaller dose of this agent was given, more 99m Tc-PAHIDA was concentrated in kidney and, at the same time, the level of its binding to plasma protein was lower. The experimental results indicated that 99m Tc-PAHIDA was rapidly excreted in urine. Autoradiochromatographic examination of the urine showed a single radioactive peak corresponding to the authentic 99m Tc-PAHIDA, indicating that 99m Tc-PAHIDA was excreted in the unchanged form. (3 tabs.)

  8. Clinical comparison of diisopropyl-IDA Tc 99m and diethyl-IDA Tc 99m for evaluation of the hepatobiliary system

    International Nuclear Information System (INIS)

    Klingensmith, W.C.; Fritzberg, A.R.; Spitzer, V.M.; Kuni, C.C.; Shanahan, W.S.

    1981-01-01

    Thirty-one patients with a wide range of hepatobiliary function and clinical diagnoses were studied with both diisopropyl-IDA Tc 99m and diethyl-IDA Tc 99m. Images were similar except for an increased liver-to-kidney ratio with diisopropyl-IDA Tc 99m (p less than 0.01) and a tendency toward an increased liver-to-background ratio at five minutes with diisopropyl-IDA Tc 99m (p greater than 0.05). Quantification of the relative hepatocyte extraction efficiency indicated a 16% higher extraction efficiency for diisopropyl-IDA Tc 99m (p greater than 0.05). Cumulative three-hour urine collections following injection demonstrated no significant difference in renal excretion in patients with normal total serum bilirubin levels. Both radiopharmaceuticals demonstrated increasing renal excretion with increasing total serum bilirubin levels; however, renal excretion of diisopropyl-IDA Tc 99m increased more slowly than excretion of diethyl-IDA Tc 99m (p less than 0.01). We conclude that, while the overall differences between these two radiopharmaceuticals are small, diisopropyl-IDA Tc 99m is superior because of a lower renal excretion rate in patients with decreased hepatocyte function

  9. Development of {sup 99m}Tc extraction-recovery by solvent extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Akihiro; Nishikata, Kaori; Izumo, Hironobu; Tsuchiya, Kunihiko; Ishihara, Masahiro [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Tanase, Masakazu; Fujisaki, Saburo; Shiina, Takayuki; Ohta, Akio; Takeuchi, Nobuhiro [Chiyoda Technol Corp., Tokyo (Japan)

    2012-03-15

    {sup 99m}Tc is used as a radiopharmaceutical in the medical field for the diagnosis, and manufactured from {sup 99}Mo, the parent nuclide. In this study, the solvent extraction with MEK was selected, and preliminary experiments were carried out using Re instead of {sup 99m}Tc. Two tests were carried out in the experiments; the one is the Re extraction test with MEK from Re-Mo solution, the other is the Re recovery test from the Re-MEK. As to the Re extraction test, and it was clear that the Re extraction yield was more than 90%. Two kinds of Re recovery tests, which are an evaporation method using the evaporator and an adsorption/elution method using the alumina column, were carried out. As to the evaporation method, the Re concentration in the collected solution increased more than 150 times. As to the adsorption/elution method, the Re concentration increased in the eluted solution more than 20 times. (author)

  10. Test performance and acceptability of self- versus provider-collected swabs for high-risk HPV DNA testing in female-to-male trans masculine patients.

    Science.gov (United States)

    Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy P; Pardee, Dana J; McLean, Sarah A; Panther, Lori A; Gelman, Marcy; Mimiaga, Matthew J; Potter, Jennifer E

    2018-01-01

    High-risk human papillomavirus (hrHPV) causes virtually all cervical cancers. Trans masculine (TM) people (those assigned female at birth who identify with a gender other than female) have low uptake of conventional cervical cancer screening. Self-collected hrHPV DNA testing has high levels of acceptability among cisgender (non-transgender) females and may support increased cervical cancer screening uptake in TM individuals. To assess the test performance and acceptability of self-collected vaginal specimens in comparison to provider-collected cervical swabs for hrHPV DNA detection in TM individuals ages 21-64 years. Between March 2015-September 2016, 150 TM participants with a cervix (mean age = 27.5 years; SD = 5.7) completed a one-time study visit comprised of a self-report survey, self-collected vaginal HPV DNA swab, clinician-administered cervical HPV swab, and brief interview on acceptability of clinical procedures. Participants were randomized to complete either self- or provider-collection first to minimize ordering effects. Self- and provider-collected samples were tested for 13 hrHPV DNA types using a DNA Hybridization Assay. The primary outcome variable was the concordance (kappa statistic) and performance (sensitivity, specificity) of self-collected vaginal HPV DNA specimens versus provider-collected cervical HPV swabs as the gold standard. Of the 131 participants completing both the self- and provider-collected HPV tests, 21 cases of hrHPV were detected by the provider cervical swab (gold standard; 16.0% hrHPV prevalence); 15 of these cases were accurately detected by the self-collected vaginal swab (71.4% concordance) (Kappa = 0.75, 95% Confidence Interval [CI]: 0.59, 0.92; p<0.001). Compared to the provider-collected cervical hrHPV DNA sample (gold standard), the self-collected vaginal hrHPV DNA test demonstrated a sensitivity of 71.4% (95% CI: 0.52, 0.91; p = 0.0495) and specificity of 98.2% (95% CI: 0.96, 1.00; p<0.0001). Over 90% of participants

  11. 49 CFR Appendix H to Part 40 - DOT Drug and Alcohol Testing Management Information System (MIS) Data Collection Form

    Science.gov (United States)

    2010-10-01

    ..., App. H Appendix H to Part 40—DOT Drug and Alcohol Testing Management Information System (MIS) Data... 49 Transportation 1 2010-10-01 2010-10-01 false DOT Drug and Alcohol Testing Management Information System (MIS) Data Collection Form H Appendix H to Part 40 Transportation Office of the Secretary...

  12. Production and clinical evaluation of 99mTc-octreotide

    International Nuclear Information System (INIS)

    Fettich, J.; Kolenc-Peitl, P.

    2004-01-01

    Full text: Due to advantages of 99m-Tc labelled radiopharmaceuticals we examined the feasibility of producing 99m-Tcoctreotide in our laboratory and compare the results with 111-In-octreotide in the same patients. Keeping constant amount of components without exceeding amount of the peptide used, preparation of 99m-Tc-ethylendiaminediacetic- acidhydrazinonicotinamide-D-Phe1,Tyr3-octreotide (99m-Tc EDDA/HYNIC-TOC) was achieved. Radiochemical purity was tested using high-pressure liquid chromatography for 24 hours. In vitro stability testing of the product showed that radiochemical purity remained above 95% for 24 hours and the radiopharmaceutical was found suitable for human use. 5 - 10 μg of the peptide labelled with 550-650 MBq of 99m-Tc was prepared for each patient. 32 patients with clinically suspicious or confirmed carcinoid were investigated with 550 - 650 MBq 99m-Tcoctreotide prepared in our laboratory followed by 110 MBq 111-In-octreotide (Octreoscan, Mallinkrodt). Whole body scintigraphy and abdominal SPECT were performed 4 and 20 hrs after injection of respective radiopharmaceutical. In all patients both studies were acquired within 5 days. All patients gave informed consent for the study as required by Ethics committee. No abnormal tracer uptake was seen anywhere in the body in 12 patient with either of the radiopharmaceuticals. These were used to assess normal distribution of both radiopharmaceuticals. Normal accumulation was seen in case of both radiopharmaceuticals in the spleen, kidneys, liver and gallbladder. Biliary activity was seen in the gut in patients that were not well prepared for the study. There was significantly less activity seen in the kidneys in case of 99m-Tc-octreotide. This could be explained by higher hydrophilicity of the 99m-Tc-EDDA/HYNEC-TOC molecules as compared with 111-In-DTPA-octreotide. 20 patients with confirmed carcinoids showed abnormal uptake but without any difference in distribution of the two radiopharmaceuticals

  13. Role of Tc-99m Sulesomab in the diagnosis of bone and joint infections

    International Nuclear Information System (INIS)

    Iyengar, K.P.; Nadkarni, J.B.; Vinjamuri, S.

    2005-01-01

    Confirming the presence of deep-seated infection in the bones and joints can be difficult, especially when routine laboratory tests and plain radiographs are inconclusive. The aim of this study was to assess the role of Tc-99m labelled anti-granulocyte monoclonal antibody Fab' fragment (Sulesomab) in bone and joint infection. Scans of 95 patients with suspected skeletal/ joint infection were studied and correlated with clinical information. Referrals consisted of suspected infection in prosthetic total joint replacements (38), long bones (32), primary joints (12) and feet (13). There were 48 female and 47 male referrals with a mean age of 60 rears (Range= 16 to 89 years). Results of routine haemogram (ESR, CRP and full blood count), plain radiographs, relevant microbiology, culture and /or histology were collected in all patients. All patients had positive Tc-99m MDP bone scan prior to Tc-99m Sulesomab scintigraphy. Patients were classified into true positives, true negatives, false positives and false negatives on the basis of final diagnosis arrived at by conclusive microbiology, surgery, complementary investigations like CT/MRI and clinical follow-up. Fifty-eight out of 95 patients had normal or equivocal blood test results. Plain radiographs revealed no abnormality or were inconclusive of infection in more than half of the patients. The Tc-99m Sulesomab scans were found to be positive in 38 patients and 57 had normal scans. Outcome classification revealed 29 true positives, 56 true negatives, 9 false positives and one false negative with an overall sensitivity of 96.66 %, specificity of 86.15 % and negative predictive value of 98.24%. Individual sensitivity, specificity and diagnostic accuracy of each category were compared. The diagnostic accuracy was found to be the highest for long bone infections (96.87%) and least for primary joint infections (83.33%). Overall the sensitivities were better than specificity in all categories. We therefore conclude that Tc

  14. Tc-99m imaging agents

    International Nuclear Information System (INIS)

    Weininger, J.; Trumper, J.

    1984-01-01

    A wide range of pharmaceuticals for labeling with Tc-99m, developed by the Soreq Radiopharmaceuticals Department, is described. Details of the production and quality control of 13 kits are given, as well as the range of results required for consistently high quality imaging agents

  15. Tc7, a Tc1-hitch hiking transposon in Caenorhabditis elegans.

    OpenAIRE

    Rezsohazy, R; van Luenen, H G; Durbin, R M; Plasterk, R H

    1997-01-01

    We have found a novel transposon in the genome of Caenorhabditis elegans. Tc7 is a 921 bp element, made up of two 345 bp inverted repeats separated by a unique, internal sequence. Tc7 does not contain an open reading frame. The outer 38 bp of the inverted repeat show 36 matches with the outer 38 bp of Tc1. This region of Tc1 contains the Tc1-transposase binding site. Furthermore, Tc7 is flanked by TA dinucleotides, just like Tc1, which presumably correspond to the target duplication generated...

  16. Acting in solidarity: Testing an extended dual pathway model of collective action by bystander group members.

    Science.gov (United States)

    Saab, Rim; Tausch, Nicole; Spears, Russell; Cheung, Wing-Yee

    2015-09-01

    We examined predictors of collective action among bystander group members in solidarity with a disadvantaged group by extending the dual pathway model of collective action, which proposes one efficacy-based and one emotion-based path to collective action (Van Zomeren, Spears, Fischer, & Leach, 2004). Based on two proposed functions of social identity performance (Klein, Spears, & Reicher, 2007), we distinguished between the efficacy of collective action at consolidating the identity of a protest movement and its efficacy at achieving social change (political efficacy). We expected identity consolidation efficacy to positively predict collective action tendencies directly and indirectly via political efficacy. We also expected collective action tendencies to be positively predicted by moral outrage and by sympathy in response to disadvantaged outgroup's suffering. These hypotheses were supported in two surveys examining intentions to protest for Palestine in Britain (Study 1), and intentions to attend the June 4th vigil in Hong Kong to commemorate the Tiananmen massacre among a sample of Hong Kong citizens (Study 2). The contributions of these findings to research on the dual pathway model of collective action and the different functions of collective action are discussed. © 2014 The British Psychological Society.

  17. Leaching TC-99 from DWPF glass in simulated geologic repository groundwaters

    International Nuclear Information System (INIS)

    Bibler, N.E.; Jurgensen, A.R.

    1986-01-01

    The purpose was to determine if DWPF glass in geologic groundwaters would immobilize Tc-99 as well as it does other elements. A previous study (using a borosilicate glass of a very different composition from DWPF glass) indicated that Tc-99 leached rapidly from the glass suggesting that glass may not be a good matrix for immobilizing Tc-99. It was suggested that the Tc-99 had migrated to vesicles in the glass while the glass was still molten. To determine if borosilicate glass was a good immobilizing matrix for Tc-99, this study was performed using DWPF glass. The leaching of Tc-99 was compared to other elements in the glass. It was shown that rapid leaching will not occur with SRP glass. The leach rate for Tc-99 was nearly identical to that for B, a matrix element in the glass. Another objective was to compare the release of Tc-99 under oxidizing and reducing conditions with other elements in the glass. In the tests described here, even though the glass was dissolving more under reducing conditions as a result of abnormally high pH values, less Tc-99 appeared in solution

  18. Development and testing of an Internet-based data collection technique for simulator and real world experimentation

    International Nuclear Information System (INIS)

    Droeivoldsmo, Asgeir; Johnsen, Terje

    2005-09-01

    With experience from many years of data collection in the Man - Machine and Virtual Reality Laboratories at the OECD Halden Reactor Project, an evident need for more efficient handling of questionnaire data was documented. A working prototype on-line system for World Wide Web (www) questionnaire generation and data collection was developed and tested. This paper discusses the use of www-based data collection and the need for system functionality in experiments and surveys. Insights from the development of the system are reported together with experiences using such tools in simulation and realistic field experimentation. (Author)

  19. In Vitro Evaluation of Tc-99m Radiopharmaceuticals for Gastric Emptying Studies

    Directory of Open Access Journals (Sweden)

    Türkan Ertay

    2014-02-01

    Full Text Available Objective: Gastrointestinal motility and functional motility disorders causing either delayed or accelerated gastric emptying (GE may result in similar symptoms including nausea, vomiting, early satiety, fullness, bloating, and abdominal discomfort or pain. Hence, it is important to evaluate patients for both rapid and delayed GE in the same test. The gold standard technique to measure GE is scintigraphy by radiolabeled test meals. The aim of this study was to test alternative Tc-99m agents to label eggs as the solid meal and compare to Tc-99m sulfur colloid (SC for gastric emptying studies. Methods: In search of alternative agents for gastric emptying studies, we mixed and fried eggs with four different particulate compounds (Tc-99m labeled SC, tin colloid, nanocolloid and MAA, as well as with free pertechnetate and Tc-99m DTPA. We then measured the stability of these compounds in simulated gastric juice. Results: Our experiments demonstrated that in addition to Tc-99m sulfur colloid;Tc-99m MAA, Tc-99m nanocolloid and Tc-99m tin colloid also appear to make stable complexes with eggs in acidic environment. Conclusion: Therefore, these agents may be used for gastric emptying studies which could be more practical in routine conditions.

  20. Hydrometeor Trajectories and Distributions in a Simulation of TC Rapid Intensification (RI)

    Science.gov (United States)

    Zhu, Z.; Zhu, P.

    2010-12-01

    It has long been recognized that the microphysics scheme used in a numerical simulation of tropical cyclones (TC) can greatly affect the precipitation distribution, intensity and thermodynamic structure of the simulated TC. This suggests that the mixing ratios, concentrations and size distributions of hydrometeor(snow, graupel,rain,cloud ice) are important factors in the evolution of TC . The transport of hydrometeor may have a strong influence on these factors through its interactions with the growth and the latent heat forcing of hydrometeor and the wind filed, hence is a key to understanding TC microphysics. Schematic hydrometeor trajectories were first constructed using 3-D wind field and particle fallspeeds derived from airborne radar observations in a steady-state mature hurricane,Alicia(1983). Since then, little effort has been put in understanding hydrometeor transport in TC, especially the potential link between its evolution and the intensity and structure changes in a non-steady-state TC. This study is focused on investigating such a link by means of numerical simulations of TC Rapid Intensification(RI) using WRF model. We use the tracer utility in WRF to construct hydrometeor trajectories. Most of the popular microphysics schemes are tested, and the most reasonable test( which is determined by comparing the simulated TC intensity and structure with airborne radar observations) and the ensemble mean of all the tests are picked for detailed examinations.

  1. TcNPR3 from Theobroma cacao functions as a repressor of the pathogen defense response.

    Science.gov (United States)

    Shi, Zi; Zhang, Yufan; Maximova, Siela N; Guiltinan, Mark J

    2013-12-06

    Arabidopsis thaliana (Arabidopsis) NON-EXPRESSOR OF PR1 (NPR1) is a transcription coactivator that plays a central role in regulating the transcriptional response to plant pathogens. Developing flowers of homozygous npr3 mutants are dramatically more resistant to infection by the pathogenic bacterium Pseudomonas syringae, suggesting a role of NPR3 as a repressor of NPR1-mediated defense response with a novel role in flower development. We report here the characterization of a putative NPR3 gene from the tropical tree species Theobroma cacao (TcNPR3). Like in Arabidopsis, TcNPR3 was constitutively expressed across a wide range of tissue types and developmental stages but with some differences in relative levels compared to Arabidopsis. To test the function of TcNPR3, we performed transgenic complementation analysis by introducing a constitutively expressing putative TcNPR3 transgene into an Arabidopsis npr3 mutant. TcNPR3 expressing Arabidopsis plants were partially restored to the WT pathogen phenotype (immature flowers susceptible to bacterial infection). To test TcNPR3 function directly in cacao tissues, a synthetic microRNA targeting TcNPR3 mRNA was transiently expressed in cacao leaves using an Agrobacterium-infiltration method. TcNPR3 knock down leaf tissues were dramatically more resistance to infection with Phytophthora capsici in a leaf bioassay, showing smaller lesion sizes and reduced pathogen replication. We conclude that TcNPR3 functions similar to the Arabidopsis NPR3 gene in the regulation of the cacao defense response. Since TcNPR3 did not show a perfect complementation of the Arabidopsis NPR3 mutation, the possibility remains that other functions of TcNPR3 remain to be found. This novel knowledge can contribute to the breeding of resistant cacao varieties against pathogens through molecular markers based approaches or biotechnological strategies.

  2. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys.

    Science.gov (United States)

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J; Mäcke, Helmut R

    2004-02-01

    The aim of this study was to compare renal handling and distribution of (99m)Tc-octreotide and (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of (99m)Tc-octreotide was three times lower than that of (99m)Tc-EDDA/HYNIC-TOC. The predominant renal excretion of (99m)Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that (99m)Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of (99m)Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation.

  3. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys

    International Nuclear Information System (INIS)

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J.; Maecke, Helmut R.

    2004-01-01

    The aim of this study was to compare renal handling and distribution of 99m Tc-octreotide and 99m Tc-EDDA/HYNIC-Tyr 3 -octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of 99m Tc-octreotide was three times lower than that of 99m Tc-EDDA/HYNIC-TOC. The predominant renal excretion of 99m Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that 99m Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of 99m Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation

  4. Physicochemical and Biological Analysis of 99mTc-Glutathione Radiopharmaceuticals

    International Nuclear Information System (INIS)

    ME- Sriyani; N- Zainuddin

    2013-01-01

    99m Tc-glutathion ( 99m Tc-GSH) radiopharmaceutical is available in the GSH lyophilized-kit in which ready to use directly after adding 99m Tc radionuclide. In nuclear medicine, 99m Tc-GSH diagnostic kit is a radiopharmaceutical commonly utilized for cancer diagnoses using imaging method. This paper described the physicochemical and biological characteristics as well as the quality of 99m Tc-GSH diagnostic kit prepared from the GSH lyophilized-kit. The radiochemical purity was determined with thin layer chromatography (TLC) method, performed on a TLC-SG stationary phase with a mobile phase of a dried acetone and 0,9% of NaCl solution. Studies on the effect of volume and radioactivity of Na 99m TcO 4 solution to the radiochemical purity of 99m Tc-GSH were carried out. The sterility of GSH-lyophilized kit and toxicity of 99m Tc-GSH were also investigated. The stability test on GSH lyophilized kit and 99m Tc-GSH in several storage conditions, as well as the plasma stability of 99m Tc-GSH was performed. The analysis result showed that the GSH lyophilized-kit was sterile; the 99m Tc-GSH was non toxic with 99.54 ± 0.01% of radiochemical purity and remained stable 5 hours either at room temperature or 4℃. The volume more than 4 mL of Na 99m TcO 4 solution on the labeling of GSH could decreased the 99m Tc-GSH radiochemical purity, while the radioactivity more than 20 mCi in 7 mL of volume extended the incubation time. In-vitro stability test of 99m Tc-GSH in plasma showed that in the two hours of storage, the radiochemical purity decreased to 51.84 ± 2.52%, and until 5 hours of storage it did not change significantly. From the result, it can be concluded that the GSH lyophilized-kit was remained stable after 13 month of storage either at room temperature or 4℃ with 99% of 99m Tc-GSH radiochemical purity. (author)

  5. Validation of an ergonomic method to withdraw [99mTc] radiopharmaceuticals.

    Science.gov (United States)

    Blondeel-Gomes, Sandy; Marie, Solène; Fouque, Julien; Loyeau, Sabrina; Madar, Olivier; Lokiec, François

    2017-11-10

    The main objective of the present work was to ensure quality of radiopharmaceuticals syringes withdrawn with a "Spinal needle/obturator In-Stopper" system. Methods: Visual examinations and physicochemical tests are performed at T0 and T+4h for [ 99m Tc]albumin nanocolloid and T+7h for [ 99m Tc]eluate, [ 99m Tc] HydroxyMethylene DiPhosphonate and [ 99m Tc]Human Serum Albumin. Microbiological validation was performed according to European pharmacopoeia. Fingertip radiation exposure was evaluated to confirm the safety of the system. Results: Results show stable visual and physicochemical properties. The integrity of the connector was not affected after 30 punctures (no cores). No microbiological contamination was found on tested syringes. Conclusion: The system could be used 30 times. The stability of syringes drawing with this method is guaranteed up to 4 hours for [ 99m Tc]albumin nanocolloid and 7 hours for [ 99m Tc]eluate, [ 99m Tc]HydroxyMethylene DisPhosphonate and [ 99m Tc]Human serum albumin. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. 77 FR 34027 - Proposed Extension of Approval of Information Collection; Comment Request-Testing and...

    Science.gov (United States)

    2012-06-08

    ... Management and Budget (OMB), of information collection requirements for manufacturers and importers of... each year varies, depending upon the number of carpet styles and the annual volume of production. CPSC... one to 200, depending upon the number of carpet styles and the annual production volume. For example...

  7. 77 FR 30540 - Proposed Collection; Comment Request; Cognitive Testing of Instrumentation and Materials for the...

    Science.gov (United States)

    2012-05-23

    ..., materials to support data collection (e.g., advance mailings, reminder letters, etc.), consent forms, and methods of administration (e.g., computer assisted personal interviews [CAPI], audio computer assisted... Assent Forms Youth 98 1 2 196 Consent Forms Adult 98 1 2 196 PATH Study Questionnaires Youth 40 1 2 80...

  8. 78 FR 6128 - Agency Information Collection Activities: Accreditation of Commercial Testing Laboratories and...

    Science.gov (United States)

    2013-01-29

    ... Record Keepers: 100. Estimated Time per Record Keeper: 60 minutes. Estimated Total Burden Hours: 100... or record keepers from the collection of information (total capital/ startup costs and operations and.... Estimated Number of Responses per Respondent: 1. Estimated Number of Total Responses: 100. Estimated Time...

  9. 49 CFR Appendix C to Part 219 - Post-Accident Testing Specimen Collection

    Science.gov (United States)

    2010-10-01

    ... the transfer of the blood tubes on the second line of STEP 5 (the chain of custody block). E. Collect... (the chain of custody block). F. Seal the Individual Employee Kit a. The blood and urine specimens have... railroad representatives handling the box shall document chain of custody of the shipping box and shall...

  10. 77 FR 13532 - Proposed Information Collection; Comment Request; 2012 National Census Test

    Science.gov (United States)

    2012-03-07

    ... Push Internet methodology. Under a Push Internet methodology, households do not receive a questionnaire...-time data processing by increasing the speed of automated coding, thus reducing and/or eliminating back... collection will be implemented using a Push Internet methodology. That is, households will receive a paper...

  11. 75 FR 59723 - Proposed Collection; Comment Request; Testing Successful Health Communications Surrounding Aging...

    Science.gov (United States)

    2010-09-28

    ... qualitative research with its key audiences--older people, caregivers, and health professionals. Methods will... issues from the National Institute on Aging (NIA). Type of Information Collection Request: New. Need and... about aging and advances in research on aging to the scientific community, health care providers, and...

  12. Indications for pediatric 99mTc-dimercaptosuccinic-scintigraphy

    International Nuclear Information System (INIS)

    Meller, J.; Becker, W.; Zappel, H.

    2000-01-01

    This paper gives an overview about the diagnostic use of 99m Tc-Dimercaptosuccinic ( 99m Tc-DMSA)-scintigraphy in siblings and children and presents our own results with this tracer in pediatric nephro-urology. 99m Tc-DMSA offers a high renal accumulation and therefore is suited for the diagnosis of renal malformations. Furthermore, a calculation of the tubular renal split function and imaging of the renal cortex is possible due its high tubular retention. The tracer may be used with success in the non invasive diagnostic work up of both renoparenchymal and renovascular hypertension in childhood and especially in the diagnosis of segmental renal artery stenosis. Scintigraphy with 99m Tc-DMSA is a simple and highly effective method in the diagnosis of pyelonephritis and renal scarring. It offers important informations about the further prognosis of a child with urinary tract infection. In upper urinary tract infection 99m Tc-DMSA-scintigraphy may be more specific than available clinical tests. In the diagnosis of pyelonephritis and renal scarring scintigraphic imaging has been proven to be more sensitive than pyelography and ultrasound and its diagnostic power is at least equal compared with computed tomography. Therefore, imaging with 99m Tc-DMSA can be considered as the reference method in these questions. Regarding that reflux is seen in less than 40% of children with a pathologic DMSA-scan and that the prognosis of children with an urinary tract infection without a pathologic DMSA-scan is usually good, one could question the use of micturating cystourethrography in the diagnostic work up of children with symptomatic urinary tract infection and a normal DMSA-scan. (orig.) [de

  13. The function of Sn(II)-apatite as a Tc immobilizing agent

    Energy Technology Data Exchange (ETDEWEB)

    Asmussen, R. Matthew, E-mail: matthew.asmussen@pnnl.gov [Energy and Environment Directorate, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, WA, 99352 (United States); Neeway, James J.; Lawter, Amanda R.; Levitskaia, Tatiana G. [Energy and Environment Directorate, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, WA, 99352 (United States); Lukens, Wayne W. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720 (United States); Qafoku, Nikolla P. [Energy and Environment Directorate, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, WA, 99352 (United States)

    2016-11-15

    At the U.S. Department of Energy Hanford Site, Tc-99 is a component of low-activity waste (LAW) fractions of the nuclear tank waste and removal of Tc from LAW streams would greatly benefit the site remediation process. In this study, we investigated the removal of Tc(VII), as pertechnetate, from deionized water (DIW) and a LAW simulant through batch sorption testing and solid phase characterization using tin (II) apatite (Sn-A) and SnCl{sub 2}. Sn-A showed higher levels of Tc removal from both DIW and LAW simulant. Scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/XEDS) and X-ray absorption spectroscopy (XAS) of reacted Sn-A in DIW showed that TcO4- is reduced to Tc(IV) on the Sn-A surface. The performance of Sn-A in the LAW simulant was lowered due to a combined effect of the high alkalinity, which lead to an increased dissolution of Sn from the Sn-A, and a preference for the reduction of Cr(VI). - Highlights: • Sn(II)-Apatite shows high proficiency in removing Tc(VII) from neutral solutions. • The removal of the Tc(VII) by Sn(II)-apatite is done via reduction to Tc(IV)O{sub 2} × H{sub 2}O. • In LAW Sn(II)-apatite is less efficient in removing Tc(VII). • Interference in LAW due to a preference for the reduction of Cr(VI) and the high pH. • Sn(II)-apatite can remove Tc(VII) from LAW effectively through increasing material added.

  14. Oxidative Stability of Tc(I) Tricarbonyl Species Relevant to the Hanford Tank Waste

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, Sayandev [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hall, Gabriel B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Levitskaia, Tatiana G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Walter, Eric D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Washton, Nancy M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-12-17

    Technetium (Tc), which exists predominately in the liquid supernatant and salt cake fractions of the nuclear tank waste stored at the U.S. DOE Hanford Site, is one of the most difficult contaminants to dispose of and/or remediate. In the strongly alkaline environments prevalent in the tank waste, its dominant chemical form is pertechnetate (TcO4-, oxidation state +7). However, based on experimentation to-date, a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non-pertechnetate species. The presence of a non pertechnetate species significantly complicates disposition of low-activity waste (LAW), and the development of methods to either convert them to pertechnetate or to separate the non-pertechnetate species directly is needed. The challenge is the uncertainty regarding the nature and stability of the alkaline-soluble, low-valence, non pertechnetate species in the liquid tank waste. One objective of the Tc management project is to address this knowledge gap. This fiscal year (FY) 2015 report summarizes experimental work exploring the oxidative stability of model low-valence Tc(I) tricarbonyl species, derived from the [Tc(CO)3]+ moiety. These compounds are of interest due to their implied presence in several Hanford tank waste supernatants. Work in part was initiated in FY 2014, and a series of samples containing non-pertechnetate Tc generated ex situ or in situ in pseudo-Hanford tank supernatant simulant solutions was prepared and monitored for oxidation to Tc(VII) (Levitskaia et al. 2014). This experimentation continued in FY 2015, and new series of samples containing Tc(I) as [Tc(CO)3]+•Ligand was tested. The monitoring method used for these studies was a combination of 99Tc NMR and EPR spectroscopies.

  15. Earth-Base: testing the temporal congruency of paleontological collections and geologic maps of North America

    Science.gov (United States)

    Heim, N. A.; Kishor, P.; McClennen, M.; Peters, S. E.

    2012-12-01

    Free and open source software and data facilitate novel research by allowing geoscientists to quickly and easily bring together disparate data that have been independently collected for many different purposes. The Earth-Base project brings together several datasets using a common space-time framework that is managed and analyzed using open source software. Earth-Base currently draws on stratigraphic, paleontologic, tectonic, geodynamic, seismic, botanical, hydrologic and cartographic data. Furthermore, Earth-Base is powered by RESTful data services operating on top of PostgreSQL and MySQL databases and the R programming environment, making much of the functionality accessible to third-parties even though the detailed data schemas are unknown to them. We demonstrate the scientific potential of Earth-Base and other FOSS by comparing the stated age of fossil collections to the age of the bedrock upon which they are geolocated. This analysis makes use of web services for the Paleobiology Database (PaleoDB), Macrostrat, the 2005 Geologic Map of North America (Garrity et al. 2009) and geologic maps of the conterminous United States. This analysis is a way to quickly assess the accuracy of temporal and spatial congruence of the paleontologic and geologic map datasets. We find that 56.1% of the 52,593 PaleoDB collections have temporally consistent ages with the bedrock upon which they are located based on the Geologic Map of North America. Surprisingly, fossil collections within the conterminous United States are more consistently located on bedrock with congruent geological ages, even though the USA maps are spatially and temporally more precise. Approximately 57% of the 37,344 PaleoDB collections in the USA are located on similarly aged geologic map units. Increased accuracy is attributed to the lumping of Pliocene and Quaternary geologic map units along the Atlantic and Gulf coastal plains in the Geologic Map of North America. The abundant Pliocene fossil collections

  16. A guide to archival collections relating to radioactive fallout from nuclear weapon testing

    International Nuclear Information System (INIS)

    1989-10-01

    This guide has been prepared by professional historians who have a working knowledge of many of the record collections, included in the following pages. In describing materials, they have tried to include enough information so that persons unfamiliar with the complexities of large record systems will be able to determine the nature of the information in, and the quality of, each record collection. The guide is organized alphabetically by the means of the record repositories, not by the organizations which have custody of the records. It should be noted that arrangement by location does not reveal at a single glance all of the materials that may have originated in a specific laboratory, research center, or government agency. For example, records originated in one of the Atomic Energy Commission's national laboratories may, in some cases, be listed under the Federal Records Centers to which they have been retired. Thus, this guide includes an index of agencies originating documents and pages listing those agencies

  17. Charge collection control using retrograde well tested by proton microprobe irradiation

    International Nuclear Information System (INIS)

    Sayama, Hirokazu; Takai, Mikio; Kimura, Hiroshi; Ohno, Yoshikazu; Satoh, Shinichi; Sonoda, Kenichirou; Katani, Norihiko.

    1993-01-01

    Soft error reduction by high-energy ion-implanted layers has been investigated by novel evaluation techniques using high-energy proton microprobes. A retrograde well formed by 160 and 700 keV boron ion implantation could completely suppress soft errors induced by the proton microprobes at 400 keV. The proton-induced current revealed the charge collection efficiency for the retrograde well structure. The collected charge for the retrograde well in the soft-error mapping was proved to be lower than the critical charge of the measured DRAMs(dynamic random-access memories). Complementary use of soft-error mapping and ion-induced-current measurement could clarify well structures immune against soft errors. (author)

  18. STOCK MARKET AND TAX REVENUE COLLECTION IN MALAYSIA: EVIDENCE FROM COINTEGRATION AND CAUSALITY TESTS

    OpenAIRE

    Roshaiza Taha

    2013-01-01

    This study empirically examined the relationship between stock market performance and taxation in Malaysia over the period 1980 to 2008. The Gregory Hansen methodology was utilized to examine which tax collected by Malaysia’s Government most impacted stock market performance in Malaysia. The results show that stock market performance contributes most to the changes in company tax revenue as compared to personal taxes and real property gain taxes. In addition, the analysis detects a signific...

  19. Assessment of Using 99Mo and 99mTc Isotopes in Kuwait Medical Sector.

    Science.gov (United States)

    Ali, Naser

    2016-04-01

    The Ministry of Health (MOH) in the state of Kuwait currently depends on importing the radioisotope molybdenum (Mo) in its isotopic form (Mo) to fulfill its demands. The present study was conducted on all nuclear medicine departments in the state of Kuwait. Daily, weekly, and monthly data were analyzed to statistically determine the current and future demands for the isotope Tc. This analysis was performed by collecting and analyzing data on MOH consumption of Tc for different diagnostic applications. The overall results indicate a partial decrease of 1.012% in the overall total demand for Tc up to the year 2018 for the state of Kuwait.

  20. Effect of hydrogen addition on the microstructure of TC21 alloy

    International Nuclear Information System (INIS)

    Zhu Tangkui; Li Miaoquan

    2010-01-01

    Research highlights: → The aim of this paper is to study the effect of hydrogen content (0-0.887 wt.%H) on microstructure, phase composition, microhardness and β transus temperature of TC21 alloy. The results show that, with increasing hydrogen content, the β phase increases, the α/β interfaces of lamellar transformed β phase disappear, the lattice parameter of β phase increases and the β transus temperature decreases for the hydrogenated TC21 alloy. In comparison to the as-received TC21 alloy, the contrasts of primary α phase and transformed β phase under optical microscope in the TC21 alloy with high hydrogen content are reversed completely. Furthermore, the γ and δ hydrides are detected in the hydrogenated TC21 alloy. In addition, the variations of phase compositions for the hydrogenated TC21 alloy have influence on microhardness and β transus temperature. → In conclusion, this paper shows some significant rules about the influence of hydrogen on TC21 alloy. - Abstract: TC21 alloy was hydrogenated at 750 deg. C with different hydrogen contents ranging from 0 to 0.873 wt.%H, and its microstructural evolution and phase transformations were investigated by optical microscopy (OM) and X-ray diffraction (XRD). The microhardness and the β transus temperature for the hydrogenated TC21 alloy were determined by microhardness testing and metallographical approach, respectively. The results show that, hydrogen addition has a noticeable influence on microstructure, phase composition, microhardness and β transus temperature of TC21 alloy. With increasing hydrogen content, the β phase increases, the α/β interfaces of lamellar transformed β phase disappear, the lattice parameter of β phase increases and the β transus temperature decreases for the hydrogenated TC21 alloy. In comparison to the as-received TC21 alloy, the contrasts of primary α phase and transformed β phase under optical microscope in the hydrogenated TC21 alloy with high hydrogen

  1. Hot deformation behavior of TC18 titanium alloy

    Directory of Open Access Journals (Sweden)

    Jia Bao-Hua

    2013-01-01

    Full Text Available Isothermal compression tests of TC18 titanium alloy at the deformation temperatures ranging from 25°C to 800°C and strain rate ranging from 10-4 to 10-2 s-1 were conducted by using a WDW-300 electronic universal testing machine. The hot deformation behavior of TC18 was characterized based on an analysis of the true stress-true strain curves of TC18 titanium alloy. The curves show that the flow stress increases with increasing the strain rate and decreases with increasing the temperature, and the strain rate play an important role in the flow stress when increasing the temperatures. By taking the effect of strain into account, an improved constitutive relationship was proposed based on the Arrhenius equation. By comparison with the experimental results, the model prediction agreed well with the experimental data, which demonstrated the established constitutive relationship was reliable and can be used to predict the hot deformation behavior of TC18 titanium alloy.

  2. 9977 TYPE B PACKAGING INTERNAL DATA COLLECTION FEASIBILITY TESTING - MAGNETIC FIELD COMMUNICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Shull, D.

    2012-06-18

    The objective of this report is to document the findings from proof-of-concept testing performed by the Savannah River National Laboratory (SRNL) R&D Engineering and Visible Assets, Inc. for the DOE Packaging Certification Program (PCP) to determine if RuBee (IEEE 1902.1) tags and readers could be used to provide a communication link from within a drum-style DOE certified Type B radioactive materials packaging. A Model 9977 Type B Packaging was used to test the read/write capability and range performance of a RuBee tag and reader. Testing was performed with the RuBee tags placed in various locations inside the packaging including inside the drum on the outside of the lid of the containment vessel and also inside of the containment vessel. This report documents the test methods and results. A path forward will also be recommended.

  3. 9978 AND 9975 TYPE B PACKAGING INTERNAL DATA COLLECTION FEASIBILITY TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Fogle, R.

    2012-05-07

    The objective of this report is to document the findings from a series of proof-of-concept tests performed by Savannah River National Laboratory (SRNL) R and D Engineering, for the DOE Packaging Certification Program to determine if a viable radio link could be established from within the stainless steel confines of several drum-style DOE certified Type B radioactive materials packagings. Two in-hand, off-the-shelf radio systems were tested. The first system was a Wi-Fi Librestream Onsight{trademark} camera with a Fortress ES820 Access Point and the second was the On-Ramp Wireless Ultra-Link Processing{trademark} (ULP) radio system. These radio systems were tested within the Model 9975 and 9978 Type B packagings at the SRNL. This report documents the test methods and results. A path forward will also be recommended.

  4. Data Collection Protocols for Adhesive Testing Results Using the Materials Selection and Analysis Tool

    Science.gov (United States)

    2012-06-01

    processing envelope will also be equally broad, as the Army employs thermosetting , thermoplastic, paste, and film adhesives cured using a variety of...Testing ASTM D 1002 13 was the basis standard used for the single-lap-joint testing. Aluminum adherends ( Alloy 2024-T3) were used with dimensions of...Surface Preparation of Aluminum Alloys to Be Adhesively Bonded in Honeycomb Shelter Panels." ASTM International, West Conshohocken, PA, 2001, DOI

  5. Labelling and quality control of 99mTc labelled somatostatin analogues

    International Nuclear Information System (INIS)

    Poramatikul, N.; Sangsuriyan, J.; Kongpeth, P.; Ngamprayad, T.; Laloknam, S.; Permtermsin, C.; Madsomboon, N.

    2001-01-01

    To standardize interlaboratory reproducibility, iodination of RC-160 with 125 I and direct labelling of RC-160 with 99m Tc, quality control and binding assay were performed. Two conjugated peptides, HYNIC-RC-160 and MAG-3-RC-160, were synthesized. The conjugated peptides were radiolabelled with 99m Tc via co-ligands; 99m Tc-MAG-3-RC-160 via glucoheptonate, 99m Tc-HYNIC-RC-160 via EDDA and tricine. Conditions for labelling were optimized. Analytical and purification methods for the labelled products were developed. Radiochemical purity test of 99m Tc labelled peptides was performed by HPLC with gradient elution of 0.1%TFA/water and acetonitrile, or by ITLC-SG in saline and in 50% acetonitrile. The contaminants in 99m Tc radiolabelled product were separated by elution from SEPPAK C-18 cartridge by 0.1% acetic acid and the pure product was eluted out of SEPPAK column by 50% acetonitrile with about 68% recovery. Stability of the purified 99m Tc-MAG3-RC-160 stored at -20 deg. C was more than 72 h. 99m Tc-MAG-3-RC-160 showed a high equilibrium dissociation constant with K D of 26 pmole/mg protein and B max of 7.9 mM. (author)

  6. Clinical evaluation of hepatic scintigraphy using sup 99m Tc-GSA

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Katsumi; Nishiyama, Shogo; Nishimaki, Hiroshi; Tadokoro, Katsumi; Ikeda, Toshiaki; Matsubayashi, Takashi; Ishii, Kodo (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1992-06-01

    Functional hepatic imaging was performed using {sup 99m}Tc-DTPA-galactosyl human serum albumin ({sup 99m}Tc-GSA), a radiolabeled ligand that reacts specifically to the asialoglycoprotein receptor that resides at the plasma membrane of hepatocytes, in 21 patients: five with chronic active hepatitis (CAH), 14 with compensative liver cirrhosis (LC), one with chronic inactive hepatitis and one with acute hepatitis. The former two diseases were mainly investigated. Serial liver images were acquired at the rates of 10 sec/frame for 0-5 min and 2 min/frame for 6-30 min after the injection of {sup 99m}Tc-GSA, and the images were compared with {sup 99m}Tc-phytase images in 2 patients with CAH and 11 with LC, and those with portal scintigrams using {sup 123}I-iodoamphetamine (IMP) in 3 patients with LC. The images using {sup 99m}Tc-GSA were in better agreement with hepatic function than those using {sup 99m}Tc-phytase, and with the findings of portal scintigraphy using {sup 123}I-IMP. LHL15 (liver/liver and heart radioactivities at 15 min after injection of {sup 99m}Tc-GSA) correlated with the hepaplastin test (r=0.978 in CAH, and r=0.544 in LC), indicators of hepatic reserve. These results suggest that liver scintigraphy using {sup 99m}Tc-GSA might be a useful method for evaluating liver function. (author).

  7. Clinical evaluation of hepatic scintigraphy using 99mTc-GSA

    International Nuclear Information System (INIS)

    Ishii, Katsumi; Nishiyama, Shogo; Nishimaki, Hiroshi; Tadokoro, Katsumi; Ikeda, Toshiaki; Matsubayashi, Takashi; Ishii, Kodo

    1992-01-01

    Functional hepatic imaging was performed using 99m Tc-DTPA-galactosyl human serum albumin ( 99m Tc-GSA), a radiolabeled ligand that reacts specifically to the asialoglycoprotein receptor that resides at the plasma membrane of hepatocytes, in 21 patients: five with chronic active hepatitis (CAH), 14 with compensative liver cirrhosis (LC), one with chronic inactive hepatitis and one with acute hepatitis. The former two diseases were mainly investigated. Serial liver images were acquired at the rates of 10 sec/frame for 0-5 min and 2 min/frame for 6-30 min after the injection of 99m Tc-GSA, and the images were compared with 99m Tc-phytase images in 2 patients with CAH and 11 with LC, and those with portal scintigrams using 123 I-iodoamphetamine (IMP) in 3 patients with LC. The images using 99m Tc-GSA were in better agreement with hepatic function than those using 99m Tc-phytase, and with the findings of portal scintigraphy using 123 I-IMP. LHL15 (liver/liver and heart radioactivities at 15 min after injection of 99m Tc-GSA) correlated with the hepaplastin test (r=0.978 in CAH, and r=0.544 in LC), indicators of hepatic reserve. These results suggest that liver scintigraphy using 99m Tc-GSA might be a useful method for evaluating liver function. (author)

  8. Preparation of 99sup(m)Tc pyridoxylideneglutamate as an imaging agent for gall bladder

    International Nuclear Information System (INIS)

    Fraga de Suarez, A.; Mitta, A.E.A.; Parera, V.E.

    1980-04-01

    The preparation of pyridoxylideneglutamate 99 sup(m)Tc is described ITLC (S.G.) is suggested as a test method, the compound was assayed in rabbits and the stability of a non liofilized kit was determined. (author) [es

  9. Microbial reduction of 99Tc (as TcO4-) in anaerobic alkaline conditions

    International Nuclear Information System (INIS)

    Khizhnyak, T.; Simonoff, M.; Sergeant, C.; Simonoff, G.; Medvedeva-Lyalikova, N.N.

    2003-01-01

    The ability of bacteria to reduce pertechnetate in alkaline conditions was investigated using halophilic bacteria isolated from soda-lakes environments. Anaerobic halophilic bacteria were able to reduce as much as 0.25 mM pertechnetate, whereas no reduction took place without bacteria or in the presence of heat-killed bacteria. The results obtained showed reduction of Tc(VII)O 4 - to the Tc(V) and Tc(IV) at pH 10 in the carbonate-bicarbonate medium. About 57% of the total technetium was determined to be Tc(IV), 1-3% as a Tc(V) and 17-20% as a Tc(VII) after 1-3 days of incubation with bacteria. The microbial reduction of Tc(VII) in alkaline conditions has been suggested as a potential mechanism for the removal of Tc from contaminated environments or waste streams. (author)

  10. Performing T-tests to Compare Autocorrelated Time Series Data Collected from Direct-Reading Instruments.

    Science.gov (United States)

    O'Shaughnessy, Patrick; Cavanaugh, Joseph E

    2015-01-01

    Industrial hygienists now commonly use direct-reading instruments to evaluate hazards in the workplace. The stored values over time from these instruments constitute a time series of measurements that are often autocorrelated. Given the need to statistically compare two occupational scenarios using values from a direct-reading instrument, a t-test must consider measurement autocorrelation or the resulting test will have a largely inflated type-1 error probability (false rejection of the null hypothesis). A method is described for both the one-sample and two-sample cases which properly adjusts for autocorrelation. This method involves the computation of an "equivalent sample size" that effectively decreases the actual sample size when determining the standard error of the mean for the time series. An example is provided for the one-sample case, and an example is given where a two-sample t-test is conducted for two autocorrelated time series comprised of lognormally distributed measurements.

  11. Tc(V)-DMS tumour imaging agent

    International Nuclear Information System (INIS)

    Horiuchi, K.; Yomoda, I.; Yokoyama, A.; Endo, K.; Torizuka, K.

    1986-01-01

    The data obtained by the authors provide good evidence of Tc(V)-DMS as a stable, large-molecular-size Tc-complex or polynuclear Tc-complex, comparable to Tc-cit and Ga-cit. A role for this polynuclear configuration in the generation of Tc-species with affinity for neoplastic cells was demonstrated using the dilution method as a promoter of Tc(V)-DMS dissociation. The concurrent Ehrlich ascites tumour cell uptake studies with TLC analysis revealed the chromatographically detected changes well traced by the biological cell utilization. The biological implications of dilution as one of the factors regulating radiopharmaceutical delivery to the tumour cell tissue were better demonstrated in the biodistribution studies carried out with Erhlich ascites-bearing mice. If, on the basis of the present data, the authors may take their postulate one step further, a more dissociated Tc-species, defined speculatively as TcO/sub 4//sup 3-/, might constitute an active Tc- species within the cell interacting with some tumour-specific substance or site. Research to find evidence of its presence is currently in progress

  12. Natural resource collection and desired family size: a longitudinal test of environment-population theories.

    Science.gov (United States)

    Brauner-Otto, Sarah R; Axinn, William G

    2017-06-01

    Theories relating the changing environment to human fertility predict declining natural resources may actually increase the demand for children. Unfortunately most previous empirical studies have been limited to cross-sectional designs that limit our ability to understand links between processes that change over time. We take advantage of longitudinal measurement spanning more than a decade of change in the natural environment, household agricultural behaviors, and individual fertility preferences to reexamine this question. Using fixed-effects models, we find that women experiencing increasing time required to collect firewood to heat and cook or fodder to feed animals (the dominant needs for natural resources in this setting) increased their desired family size, even as many other macro-level changes have reduced desired family size. In contrast to previous, cross-sectional studies we find no evidence of such a relationship for men. Our findings regarding time spent collecting firewood are also new. These results support the "vicious circle" perspective and economic theories of fertility pointing to the value of children for household labor. This feedback from natural resource constraint to increased fertility is an important mechanism for understanding long term environmental change.

  13. Study on chromosome aberrations test determinated by micro-whole blood culture in vacuum blood collection tube

    International Nuclear Information System (INIS)

    Zhong Zhihong; Han Fang'an; Ge Qinjuan; Wu Xiao; Chen Juan

    2006-01-01

    Objective: To develop an easier and efficient method of culturing the chromosome and analyzing the aberrations in peripheral lymphocytes. Methods: Micro whole was cultured for 54 hours in home-made vacuum blood collection tube, and then collection, slice-making, microscopy detection for the chromosome aberrations was done. The difference of the results was analysed by comparing with the common method. Results: For 60 radiologists and 30 contrasts, the chromosome aberrations in peripheral lymphocytes were examed by this system, the lymphocytes and chromosome were clear and alive and easier to analyse. Compared with the common method, there was no significantly difference between the two analyzing results. Conclusion: The chromosome aberrations test by micro whole blood culture in vacuum blood collection tube is easier and efficient, and is worthy of being widely popularized. (authors)

  14. Using Tc-Re chemical analogy to synthesize and identify new 99mTc complexes

    International Nuclear Information System (INIS)

    Gambino, D.; Kremer, C.; Cartesio, S.; Leon, A.; Kremer, E.

    1989-01-01

    The strong chemical resemblance between Tc and Re is applied to design and evaluate experiments with 99m Tc complexes. A combination of spectrophotometric and electrophoretic techniques allows to propose the formula [TcO 2 (amine) 2 ] + for compounds prepared by reduction of 99m TcO 4 - with Zn (solid phase) in presence of several (bidentate) amines. (author) 10 refs.; 2 figs.; 4 tabs

  15. Superconductivity in the W-Tc and W2C-Tc systems

    International Nuclear Information System (INIS)

    Giorgi, A.L.

    1985-01-01

    A series of compositions in the W-Tc, W 2 C-Re and W 2 C-Tc systems were prepared and examined for superconductivity. The crystal structure, lattice parameters and superconducting transition temperatures of the W 2 C-Tc are reported for the first time. Similar measurements were made on the W-Tc and W 2 C-Re systems and the results compared with previous published results for these systems. 7 refs., 2 figs., 2 tabs

  16. Extensive tests of Hybrid Photon Detectors (HPD) used to collect Cherenkov light

    International Nuclear Information System (INIS)

    Borsato, E.; Buccheri, A.; DalCorso, F.; Ferroni, F.; Iacovella, F.; Mazzoni, M.A.; Morandin, M.; Morganti, S.; Piredda, G.; Posocco, M.; Santacesaria, R.; Stroili, R.; Torassa, E.; Voci, C.

    1997-01-01

    The principle of operation of a newly developed proximity focused Hybrid Photon Detector is described. The HPD characteristics, performance and calibration are reported. Results from beam tests of aerogel threshold counters read out by HPD and the particle identification performance are presented. (orig.)

  17. 78 FR 77646 - Proposed Information Collection; Comment Request; 2014 Census Site Test

    Science.gov (United States)

    2013-12-24

    ... improve self- response, the Census Bureau plans to test new contact and notification strategies such as... physical location, and provide a preference for a contact strategy of either email or text. Furthermore... will be a communications and promotional campaign designed to increase awareness and encourage...

  18. 78 FR 694 - Proposed Extension of Approval of Information Collection; Comment Request-Testing and...

    Science.gov (United States)

    2013-01-04

    ... ignition of mattresses, 16 CFR part 1632. The Open- Flame standard is intended to reduce unreasonable risks... may be introduced into commerce. The Office of Management and Budget (OMB) previously approved the... suppliers, and confirmation test records, if establishments choose to pool a prototype. This documentation...

  19. Pharmaceutical design and pharmacological characterization of Tc99m [99mTc] labelled somatostatin and gastrin analogues

    International Nuclear Information System (INIS)

    Guggenberg, E. von

    2004-10-01

    The development of regulatory peptide analogues radiolabelled with 99m Tc is of great interest for nuclear medicine applications, as 99m Tc shows very favourable imaging characteristics, such as low radiation burden to the patient, optimal image quality in SPECT, one-day-acquisition-protocol, availability on demand and cost effectiveness. In this work the principles of pharmaceutical design and preclinical pharmacological characterization of regulatory peptide analogues labelled with 99m Tc with possible application in tumour diagnosis are described. [ 99m Tc-EDDA-HYNIC0,Tyr3]octreotide ( 99m Tc-EDDA-HYNIC-TOC) is a promising new radiopharmaceutical with the potential to replace [ 111 In-DTPA0]octreotide in receptor scintigraphy of somatostatin receptor-positive tumours. Radiolabelling at high labelling yields and high specific activities could be obtained applying a coligand exchange labelling approach from tricine for EDDA under optimized conditions of pH, EDDA and stannous ion concentration. The resulting complex was characterized via HPLC, receptor binding and LC-MS. For the development of a freeze-dried kit formulation with long shelf-life, high stability of the final preparation and retained biological activity, the addition of bulking agent, the pH of the freeze-drying solution and the content of stannous chloride were of major importance. Different methods of radiochemical purity testing were evaluated to guarantee high quality of the preparation in a clinical setting, forming the basis for a further clinical evaluation of this promising new radiopharmaceutical. Radiolabelling of [D-Glu1]minigastrin (MG) with 99m Tc was studied applying two different labelling approaches. HYNIC-MG could be labelled using tricine and EDDA as coligands; and (Nalpha-His)Ac-MG was used as tridentate ligand for the 99m Tc carbonyl core. Stability experiments by HPLC analysis in PBS, serum, histidine- and cysteine-solutions as well as rat liver and kidney homogenates, receptor

  20. Democratization and Political Change as Threats to Collective Sentiments: Testing Durkheim in Russia.

    Science.gov (United States)

    Pridemore, William Alex; Kim, Sang-Weon

    2006-05-01

    Durkheim argued that acute political crises result in increased homicide rates because they pose a threat to sentiments about the collective. Though crucial to Durkheim's work on homicide, this idea remains untested. The authors took advantage of the natural experiment of the collapse of the Soviet Union to examine this hypothesis. Using data from Russian regions (N = 78) and controlling for measures of anomie and other covariates, the authors estimated the association between political change and change in homicide rates between 1991 and 2000. Results indicated that regions exhibiting less support for the Communist Party in 2000 (and thus greater change in political ideals because the Party had previously exercised complete control) were regions with greater increases in homicide rates. Thus, while democratization may be a positive development relative to the Communist juggernaut of the past, it appears that the swift political change in Russia is partially responsible for the higher rates of violence there following the collapse of the Soviet Union.

  1. Recycle Waste Collection Tank (RWCT) simulant testing in the PVTD feed preparation system

    International Nuclear Information System (INIS)

    Abrigo, G.P.; Daume, J.T.; Halstead, S.D.; Myers, R.L.; Beckette, M.R.; Freeman, C.J.; Hatchell, B.K.

    1996-03-01

    (This is part of the radwaste vitrification program at Hanford.) RWCT was to routinely receive final canister decontamination sand blast frit and rinse water, Decontamination Waste Treatment Tank bottoms, and melter off-gas Submerged Bed Scrubber filter cake. In order to address the design needs of the RWCT system to meet performance levels, the PNL Vitrification Technology (PVTD) program used the Feed Preparation Test System (FPTS) to evaluate its equipment and performance for a simulant of RWCT slurry. (FPTS is an adaptation of the Defense Waste Processing Facility feed preparation system and represents the initially proposed Hanford Waste Vitrification Plant feed preparation system designed by Fluor-Daniel, Inc.) The following were determined: mixing performance, pump priming, pump performance, simulant flow characterization, evaporator and condenser performance, and ammonia dispersion. The RWCT test had two runs, one with and one without tank baffles

  2. Development of kits for 99mTc radiopharmaceuticals for infection imaging. Report of a co-ordinated research project 2000-2003

    International Nuclear Information System (INIS)

    2004-09-01

    Infectious diseases remain a major health problem and cause of death worldwide, particularly in developing countries. Nuclear medicine imaging, because of its sensitivity, offers an attractive option for diagnosis of focal infections. This needs a reliable radiopharmaceutical that can selectively concentrate in sites of infection. Over the years 67 Ga and other radiopharmaceuticals that localize in inflammation associated with infection sites, also known as 'non-specific agents' have been used for infection imaging. However, experience has shown that an 'infection specific agent' that concentrates selectively at sites of infection and not inflammation would have several advantages. The first such agent developed more than two decades ago was 111 In-leucocytes which is still considered a 'gold standard'. Considerations of cost, availability, and superior properties for imaging make 99 mTc a better label than 111 In. 99 mTc white blood cell (WBC) was developed subsequently and used for infection imaging. However, both 111 In and 99 mTc WBCs have a number of drawbacks, in particular: each patient's blood sample has to be collected and individually radiolabelled; well-trained staff and suitable facilities for separating and labelling the patient's blood are needed; the risk of infection and cross-contamination associated with potential blood-borne microorganisms; and cost of materials. Because of these, considerable efforts have been continuously made towards developing convenient replacements for 99 mTc WBCs with limited success, 99 mTc antigranulocyte antibody being a good example. However, these radiopharmaceuticals still have many disadvantages, related to either their cost and availability or their performance. In view of the large potential for applications in patients, the development of new and improved 99 mTc labelled infection specific imaging agents was considered as a very worthwhile aim for scientific research in general and, in particular, for the

  3. Household Intertemporal Behaviour: A Collective Characterization and a Test of Commitment

    OpenAIRE

    Maurizio Mazzocco

    2007-01-01

    In this paper, a formal test of intra-household commitment is derived and performed. To that end, two models of household intertemporal behaviour are developed. In both models, household members are characterized by individual preferences. In the first formulation, household decisions are always on the ex ante Pareto frontier. In the second model, the assumption of intra-household commitment required by ex ante efficiency is relaxed. It is shown that the full-efficiency household Euler equati...

  4. A feasibility test of using smartphones to collect GPS information in face-to-face surveys

    Directory of Open Access Journals (Sweden)

    Kristen Olson

    2015-02-01

    Full Text Available Survey organizations rely on interviewers to make informed and efficient decisions about their efforts in the field, including which housing units they approach to knock on doors, make appointments, and obtain interviews. This paper presents initial findings from a feasibility test on a face to face survey, the US National Survey of Family Growth, in which the interviewers were equipped with GPS-enabled smartphones. This test included an experiment to determine if the use of the GPS-enabled smartphone altered interviewer behavior. We evaluate interviewer compliance with the GPS request, the effects of using the GPS device on interviewer behavior, and the quality of the recorded GPS points as related to interviewer behaviors. This test also included two surveys of interviewers that were completed after using the smartphone. We report results from these surveys and link one set of survey results to interviewer GPS compliance rates. Implications for future use of GPS devices to monitor and understand interviewer travel behavior are discussed.

  5. Differences and similarities of the Eocene to recent Sphaerogypsina tests collected from the Pannonian basin to the Adriatic Sea

    Science.gov (United States)

    Drobne, Katica; Ćosović, Vlasta; Čretnik, Janko; Turk, Janez; Briguglio, Antonino; Rögl, Fred; Praprotnik, Anton

    2017-04-01

    With a new series of shots in the X-ray tomographic techniques (CT), the study of fossil (Eocene and Miocene) and recent tests of Sphaerogypsina globulus (Reuss, 1848) sensu lato, sampled in the Adriatic Sea and adjacent coastal areas, have continued. The Eocene, Lutetian samples collected at the NW margin of the Central Neotethys (Benkovac) contain tests up to 2 mm in diameters, while specimens found in Priabonian deposits from the southern outskirts of the Eastern Alps (Šuštarica, Ravna Gora) and in the central Pannonian basin (Eger) are smaller, with diameters of 1.2 mm. In the Oligocene, Rupelian, sediments, deposited in the Slovenian corridor, area south of the E. Alps, known as representing transition between recessing Neotethys and emerging Pannonian Sea, (Gornji grad, Nova Štifta), foraminiferal tests are of 1.1 mm in diameter. Globular tests of Miocene, Badenian, specimens (Nussdorf, north of the E. Alps), originally described as bryozoan Ceriopora globulus by Reuss 1848, attained 1.2 mm in diameter. Comparison of tests diameters shows that Middle Eocene sphaerogypsinids had the largest tests among fossil taxa, implying that warm temperatures suited them a lot. The Oligocene tests, were smaller and the trend of decreasing in size persisted in the Miocene. Recent tests, although collected over decades from different places in the Adriatic Sea, just recently have been systematically sampled at Pakleni Is. (Hvar), Kornati archipelago and Mali Čutin Is., and studied.The tests, with diameters ranging from 0.3 to 1.0 mm (an average of 0.6 to 0.8 mm), are very small in comparison with fossil forms. The life habitats, as type of substrate, light (sunny vs. shadowed areas) have been investigated, revealing that sphaerogypsinids prefer to live at water depth up to 50 - 60 m. Special attention is payed to find live specimens, which would provide the basis for DNA analysis. The application of micro- tomography contributed significantly in studying test internal

  6. Scavenging of Tc(V) formed by I.T. in 95mTcO4- solutions

    International Nuclear Information System (INIS)

    Ianoz, E.; Colin, M.; Kosinski, M.

    1988-01-01

    The chemical effects of the I.T. of 95m Tc in 95m TcO 4 - have been studied in chelating ligand solutions. At high pH and at high concentration of 1,4,8,11-tetraazacyclotetradecane and 1,4-dithia-8, 11-diazacyclotetradecane, the retention of 95g Tc is about 20% and the unretained 95g Tc appears preponderantly (ca. 73%) as [TcO 2 L] + complexes. In glucoheptonate solution, the 95g Tc retention remains practically the same (22%) but the unretained 95g Tc is found in high proportion (73%) as [TcObis(glucoheptonate)] - . The added ligands are very good scavengers for 95g Tc(V). A comparison is made between 95g Tc species formed by the I.T. in 95m TcO 4 - and 99m Tc species resulting from the chemical reduction of 99m TcO 4 - . (orig.)

  7. The influence of stereoisomerism on the pharmacokinetics of Tc radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, L.; Taylor, A. [Atlanta, Emory Univ. School of Medicine, GA (United States). Dept. of Chemistry; Marzilli, L.G. [Atlanta, Emory Univ. School of Medicine, GA (United States). Dept. of Radiology

    1998-12-01

    The influence of stereoisomerism on the pharmacokinetics of Tc mono-oxo complexes is reviewed. Tc(V) mono-oxo complexes formed with N/S ligands have four donor groups from the ligands in an equatorial plane; the oxo ligand coordinates in an axial position. Stereoisomerism in Tc(V) mono-oxo complexes can be centered within the ligand (carbon atom in the chelate ring of ligating nitrogen of amine donors) or at the Tc. The metal center becomes chiral when an equatorial ligand has a head and a tail (i.e. the two ends of the ligand differ). All types of stereocenter can produce significantly different pharmacokinetic profiles for individual isomers. Thus, biological evaluation of separated stereoisomers is necessary to identify the optimal stereochemical configuration, particularly for radiopharmaceuticals targeted to receptor molecules with low specificity. Because of inter species variation, there is ultimately no substitute for human testing. Although it is possible that the increase in nonspecific binding of agents incorporating L- vs D-amino acids may more than offset any increased receptor binding, much more information is needed. Stereochemical factors can also lead to unpredictable differences in coordination geometry and thermodynamic preference of a single isomer; thus chemical characterization of stereo-isomers continues to be an important component of radiopharmaceutical development.

  8. Solubility study of Tc(IV) oxides

    International Nuclear Information System (INIS)

    Liu, D.J.; Fan, X.H.

    2005-01-01

    The deep geological disposal of the high level radioactive wastes is expected to be a safer disposal method in most countries. The long-lived fission product 99 Tc is present in large quantities in nuclear wastes and its chemical behavior in aqueous solution is of considerable interest. Under oxidizing conditions technetium exists as the anionic species TcO 4 - whereas under the reducing conditions, expected to exist in a deep geological repository, it is generally predicted that technetium will be present as TcO 2 ·nH 2 O. Hence, the mobility of Tc(IV) in reducing groundwater may be limited by the solubility of TcO 2 ·nH 2 O under these conditions. Due to this fact it is important to investigate the solubility of TcO 2 ·nH 2 O. The solubility determines the release of radionuclides from waste form and is used as a source term in radionuclide migration analysis in performance assessment of radioactive waste repository. Technetium oxide was prepared by reduction of a technetate solution with Sn 2 + . The solubility of Tc(IV) oxide has been determined in simulated groundwater and redistilled water under aerobic and anaerobic conditions. The effects of pH and CO 3 2- concentration of solution on solubility of Tc(IV) oxide were studied. The concentration of total technetium and Tc(IV) species in the solutions were periodically determined by separating the oxidized and reduced technetium species using a solvent extraction procedure and counting the beta activity of the 99 Tc with a liquid scintillation counter. The experimental results show that the rate of oxidation of Tc(IV) in simulated groundwater and redistilled water is about (1.49-1.86) x 10 -9 mol/(L·d) under aerobic conditions, but Tc(IV) in simulated groundwater and redistilled water is not oxidized under anaerobic conditions. Under aerobic or anaerobic conditions the solubility of Tc(IV) oxide in simulated groundwater and redistilled water is equal on the whole after centrifugation or ultrafiltration. The

  9. Effect of α-naphthylisothiocyanate on blood clearance of 99mTc-phytate in dogs

    International Nuclear Information System (INIS)

    Shibata, Hiroshi; Kohno, Masahiro; Katoh, Hirotake

    1989-01-01

    The effect of α-naphthylisothiocyanate (ANIT) on blood clearance of 99m Tc-phytate ( 99m Tc-P) in dogs was examined, and blood clearance test of 99m Tc-P was compared with the cases of serum transaminase test or serum bilirubin test. Serum transaminase and bilirubin levels in dogs increased after ANIT administration, however, the degree of increase in these parameters was much lower than the cases in rats. The disappearance rate of 99m Tc-P from blood in dogs decreased with the increase in dose of ANIT and with the passage of time after the ANIT administration. Changes of the blood clearance of 99m Tc-P after ANIT treatment in dogs may be influenced by the disorder in the hepatocytes rather than in the bile ductule cells. The blood clearance test of 99m Tc-P in dogs showed a sensitive reaction for the acute hepatic dysfunction induced by ANIT equally to the serum transaminase test or the serum bilirubin test. (author)

  10. Collection and Characterization of Samples for Establishment of a Serum Repository for Lyme Disease Diagnostic Test Development and Evaluation

    Science.gov (United States)

    Molins, Claudia R.; Sexton, Christopher; Young, John W.; Ashton, Laura V.; Pappert, Ryan; Beard, Charles B.

    2014-01-01

    Serological assays and a two-tiered test algorithm are recommended for laboratory confirmation of Lyme disease. In the United States, the sensitivity of two-tiered testing using commercially available serology-based assays is dependent on the stage of infection and ranges from 30% in the early localized disease stage to near 100% in late-stage disease. Other variables, including subjectivity in reading Western blots, compliance with two-tiered recommendations, use of different first- and second-tier test combinations, and use of different test samples, all contribute to variation in two-tiered test performance. The availability and use of sample sets from well-characterized Lyme disease patients and controls are needed to better assess the performance of existing tests and for development of improved assays. To address this need, the Centers for Disease Control and Prevention and the National Institutes of Health prospectively collected sera from patients at all stages of Lyme disease, as well as healthy donors and patients with look-alike diseases. Patients and healthy controls were recruited using strict inclusion and exclusion criteria. Samples from all included patients were retrospectively characterized by two-tiered testing. The results from two-tiered testing corroborated the need for novel and improved diagnostics, particularly for laboratory diagnosis of earlier stages of infection. Furthermore, the two-tiered results provide a baseline with samples from well-characterized patients that can be used in comparing the sensitivity and specificity of novel diagnostics. Panels of sera and accompanying clinical and laboratory testing results are now available to Lyme disease serological test users and researchers developing novel tests. PMID:25122862

  11. Data collection for the methods of in-pile materials testing

    International Nuclear Information System (INIS)

    Markina, N.V.; Rudkevich, A.V.; Lebedeva, E.E.

    1985-01-01

    Problems, relating to the creation of automated data banks intended for accumulatioon and systematization of data according to the methods of in-pile materials testing, taking into account their specific nature are discussed. The architecture of the bank, realized on the BESM-6 computer is described. The bank contains data on about 300 methods. The library of requests, which may be used by a user comprises about 20 descriptions. A new request description preparation and input take 5-20 min. The system answering time is from 30 sec to 3-4 min

  12. Immobilization of {sup 99}Tc (Re) using Iron-Phosphate Glasses

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Jong; Xu, Kai; Um, Woo Yong; Hrma, Pavel [Pohang Univ. of Science and Technology, Pohang (Korea, Republic of)

    2012-05-15

    Technetium-99 ({sup 99}Tc) is a fission product artificially generated during the irradiation of {sup 235}U for commercial power production or {sup 239}Pu for nuclear weapons. Under oxidizing conditions, the dominant species of Tc, the pertechnetate anion (TcO{sub 4} {sup -}), is highly soluble in ground water and thus easily transports through the geologic systems. In addition, because of its high fission yield ({approx}6 %) and long half-life (2.1x10{sup 5} yr), immobilization of {sup 99}Tc has been investigated for decades. Several waste forms such as metallic alloys, sintered titanate ceramics and chemically bonded phosphate ceramics have been proposed to encapsulate {sup 99}Tc. They have not yet been realized in the industrial-scale, mostly either due to the high volatilization of {sup 99}Tc during high temperature process (>1300 .deg. C), or the low {sup 99}Tc loading. Iron-phosphate (FeP) glasses have been developed as alternative waste forms because of their chemical durability equivalent to borosilicate glasses. Additionally, vitrification of radioactive waste by FeP glasses can be done at a relatively low temperature ({approx}1000 .deg. C) and the low-temperature process can reduce the volatilization of {sup 99}Tc significantly. Thus, this work reports the immobilization of {sup 99}Tc by FeP glasses using rhenium (Re) as a surrogate. We also examine the chemical durability of Re-containing FeP glasses using product consistency test (PCT). Experimental results reveal that FeP glass can become a promising candidate for immobilizing {sup 99}Tc

  13. Study on the metabolic peculiarities of renal radiotracer {sup 99m}Tc-PAHIDA and diagnostic use

    Energy Technology Data Exchange (ETDEWEB)

    Shoupeng, Zhu; Liuyi, Wang; Mingyue, Lun [Suzhou Medical Coll., JS (China)

    1994-11-01

    The metabolic peculiarities of renal radiotracer {sup 99m}Tc-PAHIDA and diagnostic use were studied. The results of the radioactive tracing study showed that {sup 99m}Tc-PAHIDA was distributed predominantly in kidney, and then in heart, gastrointestinal tract, liver, spleen, musculus quadriceps femoris, adipose tissue, testes and brain. It should be noted that when smaller dose of this agent was given, more {sup 99m}Tc-PAHIDA was concentrated in kidney and, at the same time, the level of its binding to plasma protein was lower. The experimental results indicated that {sup 99m}Tc-PAHIDA was rapidly excreted in urine. Autoradiochromatographic examination of the urine showed a single radioactive peak corresponding to the authentic {sup 99m}Tc-PAHIDA, indicating that {sup 99m}Tc-PAHIDA was excreted in the unchanged form. (3 tabs.).

  14. Evaluation of liver function in carbon tetrachloride-damaged rabbits by dynamic SPECT. Comparison of 99mTc-GSA and 99mTc-Sn colloid

    International Nuclear Information System (INIS)

    Kiuchi, Takaaki; Kawasaki, Yukiko; Hino, Ichirou; Kojima, Kanji; Ohkawa, Motoomi; Tanabe, Masatada; Tamai, Toyosato.

    1994-01-01

    Technetium-99m-DTPA-galactosyl human serum albumin ( 99m Tc-GSA) is a new ligand that binds specifically to asialoglycoprotein receptors in hepatocytes. We performed liver dynamic SPECT using 99m Tc-GSA and 99m Tc-Sn colloid in nine normal control rabbits and 17 chronically CCl 4 -damaged rabbits (total 29 examinations), and also performed liver function tests (ICGR 15 , Alb, etc). Using the obtained dynamic SPECT data, we analyzed the liver kinetics of 99m Tc-Sn colloid using a one-compartment model (hepatic blood flow [K]) and 99m Tc-GSA using a two-compartment model (hepatic blood flow and receptor binding [K 1 ], catabolism [K 2 ]). As the CCl 4 -treated period increased, K 1 decreased most significantly. K 1 showed the most statistically significant correlation with the results of liver function tests, ICGR 15 (p 1 showed a correlation with the hepatic fibrosis of the HAI score. From the present results, liver dynamic SPECT using 99m Tc-GSA may be said to provide a novel method for the evaluation of hepatic functional reserve. (author)

  15. Application of PXAMS technique for 36Cl analysis in soil collected at Semipalatinsk Nuclear Test Site

    International Nuclear Information System (INIS)

    Tolmachyov, S.; Maeda, Y.; Mitarai, S.; Nakashima, T.; Momoshima, N.; Yamamoto, M.

    2001-01-01

    36 Cl in soil samples from the Semipalatinsk Nuclear Test Site (former USSR) was measured at Kyushu University Tandem Laboratory (KUTL) by accelerator mass spectrometry (AMS) coupled with projectile X-ray detection (PXD) technique. The separation of competing 36 S and 3 6Cl atomic isobars, was satisfactory by PXD technique. Measured 36 Cl/Cl atom ratio was (5.0 ± 0.6) x 10 -10 and an average activity of 36 Cl was calculated as (2.0 ± 0.2) mBq/g, which is in a good agreement with that obtained by liquid scintillation counting (LSC) method previously. Currently developed AMS system at the Kyushu University can be applied for routine 36 Cl analysis at 36 Cl/Cl = 10 -11 atom ratio level. (author)

  16. 99Tc Process Monitoring System In-Lab Performance Characterization

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, Matthew J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Niver, Cynthia M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-01-01

    A 99Tc Process Monitoring (Tc-Mon) System has been designed and built for deployment at the recently constructed 200 West Pump & Treat (200W P&T) Plant in the 200 West Area ZP-1 Operable Unit of the Hanford Site. The plant is operated by CH2M Hill Plateau Remediation Company (CHPRC). The Tc-Mon system was created through collaboration between Pacific Northwest National Laboratory (PNNL) and Burge Environmental, Inc. The design of the new system has been optimized based on experience from an earlier field test (2011) of a prototype system at the 200W-ZP-1 Interim Pump & Treat Plant.

  17. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  18. Leaching Tc-99 from SRP glass in simulated tuff and salt groundwaters

    International Nuclear Information System (INIS)

    Bibler, N.E.; Jurgensen, A.R.

    1987-01-01

    Results of leach tests with Tc-99 doped SRP borosilicate waste glass are presented. The glass was prepared by melting a mixture of SRP 165 powdered frit doped with a carrier free solution of Tc-99 at 1150 0 C. Dissolution of portions of the resulting glass indicated that the Tc-99 was distributed homogeneously throughout the glass. Static leach tests up to 90 days were performed at 90 0 C in J-13 tuff groundwater or WIPP brine A at a SA/V of 100m -1 . Normalized mass losses were calculated for Tc-99 as well as all the major elements in the glass. Results indicated that under ambient oxidizing conditions Tc-99 leached no faster than the glass-forming elements of the glass. In J-13 water, Tc-99 leached congruently with B. In WIPP brine A, it leached congruently with Si. Leach rates for Li were higher in both groundwaters, probably due to a contribution from an ion exchange mechanism. Leach tests were performed under reducing conditions in J-13 water by adding Zn/Hg amalgam to the leachate. In these tests the pH increased significantly, probably because of the reaction of the amalgam with the water. In a 21-day test, the pH increased to 13 and leach rates for the glass were very high. Even though there was signifcant dissolution of the glass, the normalized mass loss based on Tc-99 was only 0.02g/m 2 . This result and the fact that reducing conditions at normal pH values do not significantly affect the dissolution of the glass, indicate that the low concentrations for Tc-99 obtained under reducing conditions are due to is solubility and not due to an increased durability of the glass. 14 refs., 2 figs., 5 tabs

  19. The influence of data collection rate, containment size and data smoothing on containment Integrated Leak Rate Tests

    International Nuclear Information System (INIS)

    Wagner, W.T.; Langan, J.P.; Norris, W.E.; Lurie, D.

    1988-01-01

    Phase I of a U.S. Nuclear Regulatory Commission contract investigated nuclear power plant Integrated Leak Rate Tests (ILRTs) using data gathered at many domestic and foreign ILRTs. The study evaluated ILRTs with the ANS criteria (in ANSI/ANS-56.8-1987) and the proposed extended ANS criteria (in draft Regulatory Guide, Task MS 021-5, October 1986). The study considered (1) the effects of data collection rates on ILRT conclusions, (2) a possible relationship between containment size, data collection rate and ILRT duration, (3) the impact of the proposed extended ANS methodology on ILRTs, and (4) the influence of data smoothing on ILRT data. The study was performed using 20 sets of Type A and 17 sets of verification data

  20. Field test to assess the effects of drilling fluids on groundwater chemistry collected from Columbia River basalts

    International Nuclear Information System (INIS)

    Graham, D.L.; Bryce, R.W.; Halko, D.J.

    1984-03-01

    The Basalt Waste Isolation Project has used water-based drilling fluids in borehole construction. Fluids begin as a mixture of Columbia River water and bentonite. Other compounds such as organic polymers, soda ash, and chromium lignosulfonate are added to attain desired fluid characteristics. A field test was conducted to assess the effects of these fluids on basaltic groundwater chemistry. A one-month hydrochemistry baseline was established for a single interlow zone in borehole DC-14. Following baseline data collection, approximately 40,000 liters of drilling fluid were injected into the interflow. Samples were collected and analyzed for anions, cations, stable and radioactive isotopes, dissolved gases, and three specific drilling fluid tracers (i.e., tritium, fluorescein, and total organic carbon), for a period of one year following injection. Nearly 8.0 million liters of fluid were removed since initiation of the test. Test results demonstrated that drilling fluid tracers are useful indicators of how well drilling fluids have been removed from a borehole. Constituents such as Na + , SO 4 -2 , and all carbon species showed increases in concentration, whereas species such as Cl - , F - , and Si demonstrated a substantial decrease in concentration as a consequence of drilling fluid injection. Stable isotope ratios of oxygen and hydrogen were insensitive to relatively small amounts ( 14 C was significantly affected by the introduction of ''live'' carbon as a result of drilling fluid injection. 8 refs., 7 figs., 2 tabs

  1. Accumulation, elimination and retention of 99Tc by duckweed

    International Nuclear Information System (INIS)

    Hattink, J.; Weltje, L.; Wolterbeek, H.Th.; Goeij, J.J.M. de

    2004-01-01

    Accumulation dynamics of the long-lived fission product technetium ( 99 Tc) in duckweed is studied. Duckweed serves as model for aquatic plants, because of its representative foliar uptake for 99 Tc. 99 Tc is irreversibly accumulated and distributed over cytoplasm, chloroplasts and mitochondria. Autoradiography showed that 99 Tc was not transported to new biomass. Irreversible storage of 99 Tc in plant biomass means that steady-state situations cannot be interpreted as a balance between uptake and elimination of 99 Tc, but that 99 Tc continuously builds up in each single duckweed plant and overall Tc concentrations are averaged over new biomass. (author)

  2. Acceptability of self-collection sampling for HPV-DNA testing in low-resource settings: a mixed methods approach.

    Science.gov (United States)

    Bansil, Pooja; Wittet, Scott; Lim, Jeanette L; Winkler, Jennifer L; Paul, Proma; Jeronimo, Jose

    2014-06-12

    Vaginal self-sampling with HPV-DNA tests is a promising primary screening method for cervical cancer. However, women's experiences, concerns and the acceptability of such tests in low-resource settings remain unknown. In India, Nicaragua, and Uganda, a mixed-method design was used to collect data from surveys (N = 3,863), qualitative interviews (N = 72; 20 providers and 52 women) and focus groups (N = 30 women) on women's and providers' experiences with self-sampling, women's opinions of sampling at home, and their future needs. Among surveyed women, 90% provided a self- collected sample. Of these, 75% reported it was easy, although 52% were initially concerned about hurting themselves and 24% were worried about not getting a good sample. Most surveyed women preferred self-sampling (78%). However it was not clear if they responded to the privacy of self-sampling or the convenience of avoiding a pelvic examination, or both. In follow-up interviews, most women reported that they didn't mind self-sampling, but many preferred to have a provider collect the vaginal sample. Most women also preferred clinic-based screening (as opposed to home-based self-sampling), because the sample could be collected by a provider, women could receive treatment if needed, and the clinic was sanitary and provided privacy. Self-sampling acceptability was higher when providers prepared women through education, allowed women to examine the collection brush, and were present during the self-collection process. Among survey respondents, aids that would facilitate self-sampling in the future were: staff help (53%), additional images in the illustrated instructions (31%), and a chance to practice beforehand with a doll/model (26%). Self-and vaginal-sampling are widely acceptable among women in low-resource settings. Providers have a unique opportunity to educate and prepare women for self-sampling and be flexible in accommodating women's preference for self-sampling.

  3. Technetium-99 ({sup 99}Tc) in annual growth segments of knotted wrack (Ascophyllum nodosum)

    Energy Technology Data Exchange (ETDEWEB)

    Heldal, Hilde Elise, E-mail: Hilde.Heldal@imr.no [Institute of Marine Research (IMR), PO Box 1870 Nordnes, N-5817 Bergen (Norway); Sjotun, Kjersti, E-mail: Kjersti.Sjotun@bio.uib.no [University of Bergen (UoB), Department of Biology, PO Box 7803, N-5020 Bergen (Norway)

    2010-10-15

    The distribution of technetium-99 ({sup 99}Tc) in annual growth segments of the brown seaweed Ascophyllum nodosum (Fucales, Phaeophyceae) from the southwestern coast of Norway is examined in samples collected from January to November 2006. A twenty-fold increase in the {sup 99}Tc-concentration from the youngest to the oldest growth segments was found. The concentrations ranged from 42 to 98 Bq/kg dry weight (d.w.) and from 964 to 1000 Bq/kg d.w. in growth segments formed in 2006 and 1996, respectively. In addition, a seasonal variation in the {sup 99}Tc concentration was observed in the actively growing 2006-segments: concentrations decreased from 98 Bq/kg d.w. in April to 54 Bq/kg d.w. in June; there was a further reduction from June to August (42 Bq/kg d.w.); and, finally there was an increase from August to November (93 Bq/kg d.w.). In most of the segments formed between 2000 and 2005, there was a tendency of slightly decreasing {sup 99}Tc-concentrations between June and November but this pattern was not observed for the older growth segments. In order to find an explanation for the non-homogenous distribution of {sup 99}Tc within thalli of A. nodosum, different hypotheses are discussed. Uptake and elimination of {sup 99}Tc appears to be most pronounced in the actively growing segments. To date, such non-homogenous distribution of {sup 99}Tc within thalli of A. nodosum has not been taken into consideration, neither in connection with sample collection nor analysis. This paper shows that special protocols must be followed if A. nodosum is going to be used as a bioindicator for {sup 99}Tc in the marine environment. A sampling strategy is proposed.

  4. A proposal for spreading and commercializing the (n, gamma) 99Tc generator

    International Nuclear Information System (INIS)

    Yoshida, Kosuke; Hishinuma, Yukio; Tatenuma, Katsuyoshi

    2006-01-01

    A practicability of 99m Tc generator based on (n, gamma) method using PZC (Poly Zirconium Compound), a Mo adsorbent with a high adsorption efficiency, has been studied by the FNCA member countries as a part of the FNCA activities; three research collaboration projects, Technetium Generator Project (TCG), Neutron Activation Analysis Project (NAA) and Neutron Spreading Project (NS) have been set up in order to achieve the significant results of the research reactor use among Asian countries. As a result of the collaboration research, practical data on the 99m Tc elution and 99 Mo breakthrough has recently been obtained by using the new 99m Tc generator based on (n, gamma) method using PZC (indicate 'PZC- 99m Tc generator' as follows). Even though unexpected amount of 99 Mo breakthrough accompanied with the 99m Tc elution treatment were currently occurred, the problem has been solved by subsequently adding an alumina column underneath the generator column containing PZC. In accordance with the realization of the practical PZC- 99m Tc generator, an administering tests to the mice with labeled compound of 99m Tc generated by PZC method have already been started by BATAN, a loading machine to simplify the process of the 99 Mo adsorption to PZC and the 99 Mo-PZC packing to a generator column has been fabricated in BATAN's hot cell to realize a mass production of PZC- 99m Tc generator, and moreover the Japanese and Indonesian patents pertaining to the production process and the loading machine of PZC- 99m Tc generator have been applied with joint application of BATAN and KAKEN Co. By the current collaboration approaches mentioned above, it is clear that the Technetium Generator Project of FNCA is now reaching to a phase where the aims of the project shall be turned from establishment of the practical PZC- 99m C generator to establishment of the delivery system of PZC- 99m Tc generator to put them into commercial use. In this paper, a practical application of the PZC- 99m

  5. Environmental Legionella spp. collected in urban test sites of South East Queensland, Australia, are virulent to human macrophages in vitro.

    Science.gov (United States)

    Lawrence, Amba; Eglezos, Sofroni; Huston, Wilhelmina

    2016-01-01

    Legionellae are frequent contaminants of potable water supplies, resulting in sporadic infections and occasional outbreaks. Isolates of Legionella were collected from urban test sites within South East Queensland and evaluated for their virulence potential in vitro. Two strains (from the species Legionella londiniensis and Legionella quinlivanii) were demonstrated to have the ability to infect human macrophages, while a strain from the species Legionella anisa did not maintain an infection over the same time course. This suggests that the spectrum of urban environmentally associated Legionella with potential to cause human disease might be greater than currently considered. Copyright © 2015 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  6. Assessment of the direct cyclotron production of (99m)Tc: An approach to crisis management of (99m)Tc shortage.

    Science.gov (United States)

    Rovais, Mohammad Reza Aboudzadeh; Aardaneh, Khosro; Aslani, Gholamreza; Rahiminejad, Ali; Yousefi, Kamran; Boulouri, Fatemeh

    2016-06-01

    Nowadays, the cyclotron production of technetium-99m ((99m)Tc) has been increased, due to the worldwide (99m)Tc generator shortage. In the present work, an improved strategy for the production of (99m)Tc, using the proton irradiation of the enriched (100)Mo was developed. The performance of this method in terms of the production yield, chemical purity, radiochemical purity, as well as radionuclide purity was evaluated. The average production yield was measured to be 356MBqμA(-1)h(-1). A good agreement was found between the calculated production yield and the experimental one. The radiochemical separation and total recovery yields of (99m)Tc were 92% and 69%, respectively. The radiochemical and the radionuclide purities of the (99m)Tc were 99% and >99.99% at the end of purification, respectively. The results of quality control tests (QC) support the concept that cyclotron-produced (99m)Tc is suitable for preparation of USP-compliant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Development of a Luminex Bead Based Assay for Diagnosis of Toxocariasis Using Recombinant Antigens Tc-CTL-1 and Tc-TES-26.

    Directory of Open Access Journals (Sweden)

    John P Anderson

    Full Text Available The clinical spectrum of human disease caused by the roundworms Toxocara canis and Toxocara cati ranges from visceral and ocular larva migrans to covert toxocariasis. The parasite is not typically recovered in affected tissues, so detection of parasite-specific antibodies is usually necessary for establishing a diagnosis. The most reliable immunodiagnostic methods use the Toxocara excretory-secretory antigens (TES-Ag in ELISA formats to detect Toxocara-specific antibodies. To eliminate the need for native parasite materials, we identified and purified immunodiagnostic antigens using 2D gel electrophoresis followed by electrospray ionization mass spectrometry. Three predominant immunoreactive proteins were found in the TES; all three had been previously described in the literature: Tc-CTL-1, Tc-TES-26, and Tc-MUC-3. We generated Escherichia coli expressed recombinant proteins for evaluation in Luminex based immunoassays. We were unable to produce a functional assay with the Tc-MUC-3 recombinant protein. Tc-CTL-1 and Tc-TES-26 were successfully coupled and tested using defined serum batteries. The use of both proteins together generated better results than if the proteins were used individually. The sensitivity and specificity of the assay for detecting visceral larval migrans using Tc-CTL-1 plus Tc-TES-26 was 99% and 94%, respectively; the sensitivity for detecting ocular larval migrans was 64%. The combined performance of the new assay was superior to the currently available EIA and could potentially be employed to replace current assays that rely on native TES-Ag.

  8. On the interaction of granite with Tc(IV) and Tc(VII) in aqueous solution

    International Nuclear Information System (INIS)

    Eriksen, T.E.; Cui, Daquing

    1991-10-01

    The behaviour of technetium in granite-groundwater systems under reducing conditions was investigated. The anion TcO 4 - was reduced to Tc(IV) and simultaneously precipitated as TcO 2 xnH 2 O on the granite surfaces. The electron sources are assumed to be iron oxides and/or iron containing minerals in the granite. The technetium concentration in ground water under repository conditions may be predicted assuming TcO 2 xnH 2 O as the solid phase and TcO(OH) 2 0 and TcO 4 - as the predominant aqueous complexes using a formation constant for TcO(OH) 2 0 of log K = -8.16 and a standard reduction potential E 0 for the reaction TcO 4 - + 3e - + 4H + = TcO 2 xnH 2 O of 0.738 V. The surface related distribution ratio K a for TcO(OH) 2 0 between Stripa granite and ground water is approximately 1 cm based on geometrical surface area. (au)

  9. Tc-99m leucoscintigraphy in surgical patients

    International Nuclear Information System (INIS)

    Durre-e-Sabih

    1990-01-01

    Leucoscintigraphy with Tc-99m-HMPAO is an important diagnostic modality for localizing of the site of infection. It has distinct advantages over gallium 67 and indium-111 labelled leukocytes, in terms of better image quality, less cell activation and the choice of using Technetium instead of In-111. This study was designed to set up the technique in AEMC, Multan Pakistan, to assess the practicality of using the procedure, and to see if the results offered additional clinical information that could affect patient management in our clinical environment. 27 patients were studied using the technique. There were 17 post-surgical patients, 4 post-partal patients and 6 patients who did no fit into the above categories. An accuracy of 81%, sensitivity of 75% and a specificity of 100 % were achieved. The spectrum of clinical presentation was broad and included post-operative infections, intra-abdominal haematoms, brain abscesses, localized peritonitis, sterile and infected intraperitoneal collections, infected pleural effusions and pyrexia of unknown origin. It was concluded that this technique is practicable in our conditions and gives important clinical information. (author)

  10. Instant thin layer chromatography (ITLC) - the most true and convenient method for the determination of radiochemical purity of Tc-99m Labeled radiopharmaceuticals

    International Nuclear Information System (INIS)

    Anwar-Ul-Azim, M.; Ansari, M.I.H.

    2007-01-01

    should be 90% to 100% for 99mTc compounds-USP XXI) Conclusion: The findings of the study indicate that routine RCP test of 99mTc-labeled radiopharmaceuticals through ITLC-SG method is a reliable one. Routine RCP measurement by this method not only prevents repeat patient study that results in increased radiation exposure to technologists and patients but also prevent the delay in reporting the study and the additional time and expenses involved. (author)

  11. Olanzapine induced Q-Tc shortening.

    Science.gov (United States)

    Shoja Shafti, Saeed; Fallah Jahromi, Parisa

    2014-12-01

    Prolongation of Q-Tc interval is commonly accepted as a surrogate marker for the ability of a drug to cause torsade de pointes. In the present study, safety of olanzapine versus risperidone was compared among a group of patients with schizophrenia to see the frequency of the electrocardiographic alterations induced by those atypical antipsychotics. Two hundred and sixty-eight female inpatients with schizophrenia entered in one of the two parallel groups to participate in an open study for random assignment to olanzapine (n = 148) or risperidone (n = 120). Standard 12-lead surface electrocardiogram (ECG) was taken from each patient at baseline, before initiation of treatment, and then at the end of management, just before discharge. The parameters that were assessed included heart rate (HR), P-R interval, QRS interval, Q-T interval (corrected = Q-Tc), ventricular activation time (VAT), ST segment, T wave, axis of QRS, and finally, interventricular conduction process. A total of 37.83% of cases in the olanzapine group and 30% in the risperidone group showed some Q-Tc changes; 13.51% and 24.32% of the patients in the olanzapine group showed prolongation and shortening of the Q-Tc, respectively, while changes in the risperidone group were restricted to only prolongation of Q-Tc. Comparison of means showed a significant increment in Q-Tc by risperidone (p = 0.02). Also, comparison of proportions in the olanzapine group showed significantly more cases with shortening of Q-Tc versus its prolongation (p = 0.01). No significant alterations with respect to other variables were evident. Olanzapine and risperidone had comparable potentiality for induction of Q-Tc changes, while production of further miscellaneous alterations in ECG was more observable in the olanzapine group compared with the risperidone group. Also shortening of Q-Tc was specific to olanzapine.

  12. sup(99m)Tc-2-mercaptopropionylglycine

    International Nuclear Information System (INIS)

    Saji, Hideo; Odori, Teruo; Morita, Rikushi; Yokoyama, Akira; Tanaka, Hisashi.

    1979-01-01

    Labeling of 2-mercaptopropionylglycine (2-MPG) with sup(99m)Tc, was studied and its chemical characteristics were examined. Further, biliary excretion behavior of this complex was comparatively estimated in mice, rats and rabbits. sup(99m)Tc-2-MPG was rapidly excreted in large quantities into the bile in mice and rats: within 1 hr after injection, 51% of the injected dose was recovered from the bile in rats. On the other hand, the ligand exchange reaction between this complex and penicillamine indicates that a low hydrolyzed sup(99m)Tc species is coordinated with 2-MPG. These results suggest that a low hydrolyzed sup(99m)Tc state is an effective feature in biliary excretion behavior of sup(99m)Tc compounds. Another interesting in vivo behavior of sup(99m)Tc-2-MPG is the difference observed in mice and rabbits: in mice, very high sup(99m)Tc activity is concentrated in the gallbladder and the clearance from tissues other than the gallbladder is rapid, whereas in rabbits, although a rapid and high excretion into the gallbladder is observed, a considerable high sup(99m)Tc activity is retained in the liver and the kidney. One reason for this different in vivo behavior is the low stability of this complex at high dilution: a big animal has the large dilution volume which lead to higher decomposition estimated by the higher liver and kidney retention or the lower bile excretion. In conclusion, studies carried on sup(99m)Tc-2-MPG showed a good biliary excretion behavior but an in vivo unstableness in big animals. (author)

  13. Assessment of hepatic functional reserve for hepatic resection using {sup 99m}Tc-PMT scintigraphy in comparison with {sup 99m}Tc-GSA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Atsushi [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    {sup 99m}Tc-diethylenetriamine-pentaacetic acid-galactosyl human serum albumin({sup 99m}Tc-GSA) scintigraphy has been reported as a useful study of hepatic functional reserve recently. We have performed {sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan({sup 99m}Tc-PMT) and {sup 99m}Tc-GSA preoperatively for evaluation of hepatic functional reserve and compared the usefulness of those scintigraphy study. Twenty-four patients who were the candidates of hepatic resection underwent {sup 99m}Tc-PMT scintigraphy preoperatively. Hepatic blood flow coefficient (K value), the amount of hepatic blood flow (HBF), and the ratio of portal blood flow (PVR) were computed. {sup 99m}Tc-GSA scintigraphy was also performed within two weeks of the {sup 99m}Tc-PMT scintigraphy, and the ratio of disappearance (HH{sub 15}) and the hepatic uptake ratio (LHL{sub 15}) were computed. The relationship between K value, HBF, PVR, HH{sub 15} and LHL{sub 15} was analyzed. Their correlation with other liver function tests was also examined. K value and HBF did not show statistically significant correlations with HH{sub 15} and LHL{sub 15}, PVR correlated statistically significantly HH{sub 15} and LHL{sub 15}. K value correlated with the preoperative values of cholinesterase, Fischer ratio, {gamma}-globulin, ICGR{sub 15}, albumin, and platelet count. There was a statistically significant correlation between LHL{sub 15} and the value of cholinesterase, {gamma}-globulin, platelet count, and Fischer ratio. When the liver resection of subsegmentectomy or more was indicated in 10 patients, nine patients had LHL{sub 15} value less than 0.9 which delineated possibility of poor prognosis. However, judging from K value and HBF, liver resection was considered feasible and it was all successfully performed, resulting in good prognosis. From this study, it is suspected that {sup 99m}Tc-GSA scintigraphy reflect the severity of liver fibrosis and the amount of portal blood flows, and {sup 99m}Tc-PMT scintigraphy

  14. Assessment of hepatic functional reserve for hepatic resection using 99mTc-PMT scintigraphy in comparison with 99mTc-GSA scintigraphy

    International Nuclear Information System (INIS)

    Sakuma, Atsushi

    2000-01-01

    99m Tc-diethylenetriamine-pentaacetic acid-galactosyl human serum albumin( 99m Tc-GSA) scintigraphy has been reported as a useful study of hepatic functional reserve recently. We have performed 99m Tc-N-pyridoxyl-5-methyl-tryptophan( 99m Tc-PMT) and 99m Tc-GSA preoperatively for evaluation of hepatic functional reserve and compared the usefulness of those scintigraphy study. Twenty-four patients who were the candidates of hepatic resection underwent 99m Tc-PMT scintigraphy preoperatively. Hepatic blood flow coefficient (K value), the amount of hepatic blood flow (HBF), and the ratio of portal blood flow (PVR) were computed. 99m Tc-GSA scintigraphy was also performed within two weeks of the 99m Tc-PMT scintigraphy, and the ratio of disappearance (HH 15 ) and the hepatic uptake ratio (LHL 15 ) were computed. The relationship between K value, HBF, PVR, HH 15 and LHL 15 was analyzed. Their correlation with other liver function tests was also examined. K value and HBF did not show statistically significant correlations with HH 15 and LHL 15 , PVR correlated statistically significantly HH 15 and LHL 15 . K value correlated with the preoperative values of cholinesterase, Fischer ratio, γ-globulin, ICGR 15 , albumin, and platelet count. There was a statistically significant correlation between LHL 15 and the value of cholinesterase, γ-globulin, platelet count, and Fischer ratio. When the liver resection of subsegmentectomy or more was indicated in 10 patients, nine patients had LHL 15 value less than 0.9 which delineated possibility of poor prognosis. However, judging from K value and HBF, liver resection was considered feasible and it was all successfully performed, resulting in good prognosis. From this study, it is suspected that 99m Tc-GSA scintigraphy reflect the severity of liver fibrosis and the amount of portal blood flows, and 99m Tc-PMT scintigraphy reflect the hepatic blood flow and ability of protein synthesis. It was proved that 99m Tc-PMT scintigraphy is

  15. Assessment of the stability of DNA in specimens collected under conditions for drug testing-A pilot study.

    Science.gov (United States)

    White, Robert M; Mitchell, John M; Hart, E Dale; Evans, Amy; Meaders, Meredith; Norsworthy, Sarah E; Hayes, Eugene D; Flegel, Ron; Maha, George C; Shaffer, Megan D; Hall, Erin M; Rogers, Kelley

    2018-02-01

    For forensic biological sample collections, the specimen donor is linked solidly to his or her specimen through a chain of custody (CoC) sometimes referenced as a chain of evidence. Rarely, a donor may deny that a urine or oral fluid (OF) specimen is his or her specimen even with a patent CoC. The goal of this pilot study was to determine the potential effects of short-term storage on the quality and quantity of DNA in both types of specimen under conditions that may be encountered with employment-related drug testing specimens. Fresh urine and freshly collected oral fluid all produced complete STR profiles. For the "pad" type OF collectors, acceptable DNA was extractable both from the buffer/preservative and the pad. Although fresh urine and OF produced complete STR profiles, partial profiles were obtained after storage for most samples. An exception was the DNA in the Quantisal OF collector, from which a complete profile was obtained for both freshly collected OF and stored OF. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Evaluation of usefulness of Tc-99m-GSA liver scintigraphy in chronic liver diseases

    International Nuclear Information System (INIS)

    Fukui, Hiroyuki; Kashiwagi, Toru; Kasahara, Akinori

    1991-01-01

    Liver scintigraphy was performed using a newly developed radiopharmaceutical, Tc-99m-DTPA-galactosyl-human-serum-albumin (Tc-99m-GSA), which binds specifically to the receptors on the hepatic cell surface, in 15 patients with chronic liver disease. The scintigraphy was evaluated qualitatively and quantitatively, and the results were compared with those obtained from the Tc-99m-PMT or Tc-99m-sn-phytate scintigraphy, and the liver function tests. The Tc-99m-GSA scintigraphy showed clear liver images in chronic hepatitis. However, in liver cirrhosis, the liver images were not clear and the cardiac images still existed 40 minutes after administration of Tc-99m-GSA, suggesting that the image quality of the Tc-99m-GSA scintigrams may be inferior to that of Tc-99m-sn-phytate or Tc-99m-PMT in some cases of severe liver dysfunction. The time-activity curves of the heart and liver were analyzed by non-linear regression analysis. The clearance rate from plasma (Kd) were obtained from the time-activity curve of the heart, and the hepatic uptake rate (Ku), hepatic excretion rate (Ke) and peak time of hepatic uptake-excretion curve (PT) were obtained from the time-activity curve of the liver. Kd, Ku, and PT values were more significantly decreased or prolonged in the patients with chronic hepatitis. Kd, Ku, and PT values had positive correlations with the result of the serum liver function tests, ICG-R15 and ICG-K. Ku and PT values had also correlations with the histological degree of hepatic fibrosis. On the other hand, the indices obtained using Tc-99m-PMT or Tc-99m-sn-phytate did not have correlations with the histological degrees of hepatic fibrosis. It is concluded that the liver scintigraphy using Tc-99m-GSA may be useful and give different information from those with conventional liver scintigraphies in evaluating chronic liver diseases. (author)

  17. Solubility of Tc(IV) oxides

    International Nuclear Information System (INIS)

    Liu, D.J.; Fan, X.H.

    2005-01-01

    Full text of publication follows: The deep geological disposal of the high level radioactive wastes is expected to be a safer disposal method in most countries. The long-lived fission product 99 Tc is present in large quantities in nuclear wastes and its chemical behavior in aqueous solution is of considerable interest. Under the reducing conditions, expected to exist in a deep geological repository, it is generally predicted that technetium will be present as TcO 2 .nH 2 O. The solubility of Tc(IV) is used as a source term in performance assessment of radioactive waste repository. Technetium oxide was prepared by reduction of a technetate solution with Sn 2+ . The solubility of Tc(IV) oxide has been determined in simulated groundwater and re-distilled water under aerobic and anaerobic conditions. The effects of pH and CO 3 2- concentration of solution on solubility of Tc(IV) oxide were studied. The concentration of total technetium and Tc(IV) species in the solutions were periodically determined by separating the oxidized and reduced technetium species using a solvent extraction procedure and counting the beta activity of the 99 Tc with a liquid scintillation counter. The experimental results show that the rate of oxidation of Tc(IV) in simulated groundwater and re-distilled water is about (1.49∼1.86) x 10 -9 mol/(L.d) under aerobic conditions, but Tc(IV) in simulated groundwater and re-distilled water is not oxidized under anaerobic conditions. Under aerobic or anaerobic conditions the solubility of Tc(IV) oxide in simulated groundwater and re-distilled water is equal on the whole after centrifugation or ultrafiltration. The solubility of Tc(IV) oxide decreases with the increase of pH at pH 10 and is pH independent in the range 2 -8 to 10 -9 mol/L at 2 3 2- concentration. These data could be used to estimate the Tc(IV) solubility for cases where solubility limits transport of technetium in reducing environments of high-level waste repositories. (authors)

  18. Study of {sup 99m}Tc-DMSA biodistribution in experimental animals

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Thais O.M. de; Silva, Natanael G. da; Colturato, Maria T.; Felgueiras, Carlos F.; Mengatti, Jair; Fukumori, Neuza T.O.; Matsuda, Margareth M.N.; Araújo, Elaine B. de, E-mail: thais.castrom@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia

    2017-11-01

    {sup 99m}Tc-DMSA, succimer ({sup 99m}Tc), is a radiopharmaceutical commonly used in nuclear medicine for renal function evaluation by imaging. In order to achieve adequate labeling of the product with good radiochemical yield and standardized biological distribution, the interval of 185 - 3700 MBq should be kept in a maximum volume of 3 mL for product labeling. Moreover, one should avoid exposing the reconstituted solution to oxygen and using the product after four hours post labeling. The aim of the study was to quantify and evaluate the influence of different DMSA complexes on biological distribution of the radiopharmaceutical in experimental animals, taking in account variations in the labeling parameters. Radiochemical purity was determined by paper and thin layer chromatography using both acetone/Whatman 3MM, 0.9% NaCl/TLC-SG and n-propanol/ H{sub 2}O/acetic acid (4:3:1 V/V/V)/TLC-SG systems respectively for quantification of {sup 99m}TcO{sub 4} - and {sup 99m}TcO{sub 2} plus some {sup 99m}Tc-DMSA complexes. The labeling activity did not significantly affect the extent of the main complex generation. The presence of oxygen and the concentration of {sup 99}Tc did not markedly change the percentage of the radiochemical impurities in the preparation. Radiochemical purity tests of the DMSA-{sup 99m}Tc based on IPEN-CNEN DMSA-TEC reagent and on another producer's reagent showed similar results. Although the routine method used by IPEN-CNEN to determine the radiochemical yield of {sup 99m}Tc-DMSA was not able to discriminate among {sup 99m}Tc-DMSA complexes, the renal uptake and the kidney to liver plus spleen uptake ratio in rats met the official compendia criteria for the radiopharmaceutical. (author)

  19. Study of "9"9"mTc-DMSA biodistribution in experimental animals

    International Nuclear Information System (INIS)

    Castro, Thais O.M. de; Silva, Natanael G. da; Colturato, Maria T.; Felgueiras, Carlos F.; Mengatti, Jair; Fukumori, Neuza T.O.; Matsuda, Margareth M.N.; Araújo, Elaine B. de

    2017-01-01

    "9"9"mTc-DMSA, succimer ("9"9"mTc), is a radiopharmaceutical commonly used in nuclear medicine for renal function evaluation by imaging. In order to achieve adequate labeling of the product with good radiochemical yield and standardized biological distribution, the interval of 185 - 3700 MBq should be kept in a maximum volume of 3 mL for product labeling. Moreover, one should avoid exposing the reconstituted solution to oxygen and using the product after four hours post labeling. The aim of the study was to quantify and evaluate the influence of different DMSA complexes on biological distribution of the radiopharmaceutical in experimental animals, taking in account variations in the labeling parameters. Radiochemical purity was determined by paper and thin layer chromatography using both acetone/Whatman 3MM, 0.9% NaCl/TLC-SG and n-propanol/ H_2O/acetic acid (4:3:1 V/V/V)/TLC-SG systems respectively for quantification of "9"9"mTcO_4 - and "9"9"mTcO_2 plus some "9"9"mTc-DMSA complexes. The labeling activity did not significantly affect the extent of the main complex generation. The presence of oxygen and the concentration of "9"9Tc did not markedly change the percentage of the radiochemical impurities in the preparation. Radiochemical purity tests of the DMSA-"9"9"mTc based on IPEN-CNEN DMSA-TEC reagent and on another producer's reagent showed similar results. Although the routine method used by IPEN-CNEN to determine the radiochemical yield of "9"9"mTc-DMSA was not able to discriminate among "9"9"mTc-DMSA complexes, the renal uptake and the kidney to liver plus spleen uptake ratio in rats met the official compendia criteria for the radiopharmaceutical. (author)

  20. [Contamination levels to room air arising from the use of 99mTc-gas and prevention from the contamination].

    Science.gov (United States)

    Komatani, A; Akutsu, T; Yamaguchi, K; Onodera, Y; Manaka, Y; Takahashi, K

    1996-04-01

    99mTc-gas (TECHNEGAS) is a 99mTc-labeled micro-aerosol which is considered to have different behavior from 133Xe or 81mKr gas. In order to estimate contamination levels to room air arising from the use of 99mTc-gas, filtered expired air during administration and 1, 2, 3, 5, 10 min after the administration were collected in each polyethylene bag. Radioactivities of the polyethylene bags, used filter and the lung were measured with 3-head scintillation camera. The activity of the expired air diminished within 6-10 min and about 5% of whole discharged 99mTc-gas was released to room air. The activity of the used filter was two times of the lung. According to these results, it is recommended that the 99mTc-gas may be administrated in a exclusive room. The administrated patient and used filter must be remain in the exclusive room.

  1. 99mTc DMSA scintigraphic findings in renal tuberculosis

    International Nuclear Information System (INIS)

    Moon, Tae Yong; Kim, Kun Il; Yoon, Chi Soon; Lee, Suck Hong; Kim, Byung Soo

    1993-01-01

    Evaluations of residual renal function and the therapeutic effectiveness in renal tuberculosis have largely been dependent on intravenous pyelogram or Contrast-CT scan, even though, exact renal functions are not evaluate with there methods. 99m Tc- DMSA is a radiopharmaceutical that is trapped in the functioning tubular cells of the kidney and therefore, quantitative renal function could be evaluated by insuring the counts of renal radioactivity and concomitant evaluation of renal morphology could be passable with the analog images of the radioactivity. The authors retrospectively analyzed 99mTc-DMSA scans of 75 kidneys of 67 patients with confirmed renal tuberculosis. We classified the morphologies of tuberculous kidneys as 6 types. We classified the morphologies of tuberculous kidneys as 6 types such as the type with small cortical defect, with parenchymal ulcerocavernous lesions, ulcerocavernous fistula to pelvis, mass-like defects, contracted kidney with ureter visualization, and the type with non visualization of kidney, corresponding to the characters of renal tuberculous pathogenesis with abscess formation, ulcerocavernous fistula, and fibrosis, and corresponding to the renal anatomy with parenchyma, and pelvocalyceal collecting system. Their mean residual renal functions measured with 99mTc-DMSA uptake rates were 19.0%,18.4%, 7.9%, 12%, 4.1%, 3.4% respectively

  2. Collecting Samples for Testing

    Science.gov (United States)

    ... Creatinine Ratio Valproic Acid Vancomycin Vanillylmandelic Acid (VMA) VAP Vitamin A Vitamin B12 and Folate Vitamin D ... that used for CSF in that they require aspiration of a sample of the fluid through a ...

  3. Evaluation of (99)  (m)TcN-MPO as a new myocardial perfusion imaging agent in normal dogs and in an acute myocardial infarction canine model: comparison with (99)  (m)Tc-sestamibi.

    Science.gov (United States)

    Bu, Lihong; Li, Renfei; Jin, Zhongnan; Wen, Xiaofei; Liu, Shuang; Yang, Baofeng; Shen, Baozhong; Chen, Xiaoyuan

    2011-02-01

    (99)  (m)TcN-MPO ([(99)  (m)TcN(mpo)(PNP5)](+): mpo = 2-mercaptopyridine oxide and PNP5 = N-ethoxyethyl-N,N-bis[2-(bis(3-methoxypropyl)phosphino)ethyl]amine) is a cationic (99)  (m)Tc-nitrido complex, which has favorable biodistribution and myocardial uptake with rapid liver clearance in Sprague Dawley rats. The objective of this study was to compare the biodistribution and pharmacokinetics of (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi in normal dogs, and to evaluate the potential of (99)  (m)TcN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. Five normal mongrel dogs were injected intravenously with (99)  (m)TcN-MPO. Venous blood samples were collected via a femoral vein catheter at 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 40, 60, and 90 min post-injection (p.i.). Anterior-posterior planar images were acquired by γ-camera at 10, 20, 30, 60, 90, and 120 min p.i. Regions of interest (ROIs) were drawn around the heart, liver, and lungs. The heart/liver and heart/lung ratios were calculated by dividing the mean counts in heart ROI by the mean counts in the liver and lung ROI, respectively. For comparison, (99)  (m)Tc-sestamibi was also evaluated in the same five dogs. The interval period between the two examinations was 1 week to eliminate possible interference between these two radiotracers. In addition, single positron emission computed tomography (SPECT) images in the canine infarct model were collected 24 h after myocardial infarction at 30 and 60 min after the administration of (99)  (m)TcN-MPO (n = 4) or (99)  (m)Tc-Sestamibi (n = 4). It was found that (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi displayed very similar blood clearance characteristics during the first 90 min p.i. Both (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min and less than 5% at 30 min p.i. (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi both showed good

  4. Comparative binding characteristics of Tc-CPI, Tc-TBI, and Tc-MIBI in cultured heart cells: Correlation with biochemical analysis and animal images

    International Nuclear Information System (INIS)

    Piwnica-Worms, D.; Kronauge, J.F.; Holman, B.L.; Davison, A.; Jones, A.G.

    1987-01-01

    Hexakis (isonitrile)technetium (I) complexes are a new class of cationic, lipophilic myocaridal perfusion imaging agents. To better understand their cellular mechanisms of uptake and washout, chick heart cells grown in culture were used as a model myocardial system. Tc-MIBI showed uptake to a plateau at a rate similar to Tc-CPI (t1/2 = 4.1 +- 0.7 minutes); however, the plateau was 63% greater. Tc-TBI uptake approached a plateau 900% greater than Tc-CPI binding. Heart cell studies showed washout of Tc-CPI>Tc-TBI>Tc-MIBI, which correlated with kinetic analysis of rabbit myocardial images. Biochemical in vitro analysis in human plasma demonstrated 75% enzymatic ester hydrolysis of Tc-CPI by 3 minutes, but no hydrolysis of Tc-TBI and Tc-MIBI. The results suggest that metabolism of the ester function of Tc-CPI following myocardial uptake may in part account for the more rapid cellular washout rates of Tc-CPI compared with Tc-TBI and Tc-MIBI

  5. 99mTc bone scanning agents preparation and chemical analysis of Tc(Sn)pyrophosphate, Tc(Sn)MDP and Tc(Sn)HMDP

    International Nuclear Information System (INIS)

    Kroesbergen, J.

    1986-01-01

    This thesis describes a comparison of the preparation, composition and properties of three bone scanning agents: 99m Tc(Sn)pyrophosphate, 99m Tc(Sn)MDP and 99m Tc(Sn)HMDP. This study has been performed for two reasons: First to investigate the preparation and composition of the radiopharmaceuticals as a function of experimental conditions. Together with previously reported results for 99m Tc(Sn)EHDP, obtained in a similar way, this enables to use well-defined preparations of the bone scanning agents. Secondly to gain an insight in the mechanism in which the agents behave 'in vivo'. Because the 'in vivo' process is too complicated to study directly, it seemed more appropriate to perform 'in vitro' investigations as simplifications of the 'in vivo' situation. 304 refs.; 26 figs.; 31 tabs

  6. Transmutation of Tc-99 in fission reactors

    International Nuclear Information System (INIS)

    Kloosterman, J.L.; Li, J.M.

    1994-12-01

    Transmutation of Tc-99 in three different types of fission reactors is considered: A heavy water reactor, a fast reactor and a light water reactor. For the first type a CANDU reactor was chosen, for the second one the Superphenix reactor, and for the third one a PWR. The three most promising Tc-99 transmuters are the fast reactor with a moderated subassembly in the inner core, a fast reactor with a non-moderated subassembly in the inner core, and a heavy water reactor with Tc-99 target pins in the moderator between the fuel bundles. Transmutation half lives of 15 to 25 years can be achieved, with yearly transmuted Tc-99 masses of about 100 kg at a thermal reactor power of about 3000 MW. (orig.)

  7. Role of Ca2+ in the binding mechanism of EHDP-Tc complex to bone

    International Nuclear Information System (INIS)

    Langevelde, A. van; Huisman, C.M.; Driessen, O.M.J.; Pauwels, E.K.J.

    1979-01-01

    Experiments are described testing the hypothesis that 99m-Tc-EHDP complex travels to bone as a unit and dissociates at the bone binding site because of the high affinity of EHDP for hydroxyapatite after which technetium binds separately. The results indicate that technetium is not dissociated from EHDP in binding to hydroxyapatite, but the EHDP-Tc-ligand stays intact. It is postulated that calcium plays an important role in bone-labelling with EHDP-Tc complex and that in fact the EHDP-Ca-Tc complex is the binding agent. Only by assuming the presence of this agent could the action of magnesium-ions or of excess calcium-ions be explained. (Auth./C.F.)

  8. Use of 99mTc-bicisate in activation studies by split-dose technique

    DEFF Research Database (Denmark)

    Holm, S; Madsen, P L; Sperling, B

    1994-01-01

    The properties of the brain single photon emission computed tomography (SPECT) tracer 99mTc-bicisate (ethyl cysteinate dimer) were examined in regard to its use in test-retest studies with short-interval, split-dose studies. The stimulus applied in these tests was a visual activation by a "flicke......The properties of the brain single photon emission computed tomography (SPECT) tracer 99mTc-bicisate (ethyl cysteinate dimer) were examined in regard to its use in test-retest studies with short-interval, split-dose studies. The stimulus applied in these tests was a visual activation...

  9. Temporal and spatial responses of the bioindicator Fucus to discharges of 99Tc in the eastern Irish Sea

    International Nuclear Information System (INIS)

    McDonald, P.; Busby, R.G.; McCartney, M.

    1999-01-01

    Technetium-99 is a radioactive isotope discharged under authorisation to the Irish Sea from the British Nuclear Fuels plc Sellafield reprocessing plant in Cumbria via a marine pipeline. An increase in 99 Tc discharges from Sellafield in recent years has provided an ideal opportunity to undertake a more detailed investigation of its environmental behaviour. Here, the temporal and spatial response of Fucus sp. to the increased discharges has been investigated and its role as a bioindicator assessed. Initial investigations in 1995, have confirmed the expectation that Fucus does act as an effective bioindicator of 99 Tc, with easily detectable 99 Tc concentrations (1 - 15 kBq kg -1 wet weight) being encountered, providing a time integrated signal of 99 Tc discharges. Analysis of subsequent samples collected during 1996, however, have shown significant short-term peaks in Fucus 99 Tc concentrations close to Sellafield (up to 90 kBq kg -1 wet weight) and this can be related to peaks in 99 Tc seawater concentrations. This type of response suggests that Fucus has a means of rapidly accumulating 99 Tc, although the rate at which this accumulated component may be eliminated remains unclear. This effect was only observed at sites close to Sellafield (within 15 km). Relatively constant 99 Tc concentrations in Fucus were found at more distant sites (50 - 150 km). (author)

  10. Tc-99m-hexakis(t-butylisonitrile)-technetium(I) (Tc-99m-TBI)

    International Nuclear Information System (INIS)

    Angelberger, P.; Dudczak, R.; Jones, A.G.; Lister-James, J.; Wagner-Loffler, M.; Buchheit, O.; Fally, F.

    1986-01-01

    The potassium analog (Tl-201)/sup +/ is widely used in nuclear cardiology but has inferior scintigraphic (80 keV photons), dosimetric and economic properties as compared to Tc-99m. Therefore considerable efforts have been made to develop a Tc-compound that would accumulate in the myocardium in relation to regional blood flow. This study was aimed at optimizing the preparation of Tc-TBI with n.c.a. Tc-99m, analyze and purify the product with HPLC, verify biodistribution in mice and undertake a clinical evaluation

  11. Radiopharmaceuticals to 99mTc

    International Nuclear Information System (INIS)

    Leon Cabana, Alba

    1994-01-01

    Studies about 99m Tc had demonstrated that have favorable properties for support diagnostic proceedings in nuclear medicine. This physical and chemical properties used for obtain another radiopharmaceuticals have been employed through re actives kits labelled with Tc 99m . A brief description was given about 99m utilities in diagnostic techniques such as endothelium reticular system,renal and hepatic studies,bone scintillators,cardiac diagnostic and cerebral perfusion

  12. Electrolytic 99TcO4- reduction at inert electrodes

    International Nuclear Information System (INIS)

    Kremer, C.; Gambino, D.; Leon, A.; Kremer, E.

    1990-01-01

    Electrolytic pertechnetate reduction at inert electrodes was studied as an alternative procedure for synthesizing Tc complexes. Pertechnetate reduction was carried out in aqueous media using different aminated ligands (en, dien, trien and 1,3-dap) forming [TcO 2 (amine) 2 ] + type complexes. Simultaneously with synthesis of the desired Tc complex, TcO 2 was electrodeposited onto the cathode. Conversion of TcO 4 - to Tc complex and TcO 2 was studied as a function of several variables (kind and concentration of supporting electrolyte, ligand concentration, pH, current and electrolysis time). (author) 9 refs.; 6 figs.; 1 tab

  13. Pharmacological study of 99mTc-CO-MIBI, a new mycoardial perfusion imaging agent comparison to 99mTc-MIBI

    International Nuclear Information System (INIS)

    Zhao Jiandong; Wang Jincheng; Mi Hongzhi

    2004-01-01

    pharmacokinetics parameters, biodistribution, T/NT radios were collected and calculated during and after the imaging. Moreover, the whole body image, heart planer scintigraphy and tomography were investigated on pharmacodynamics. The same procedure were performed to 99m Tc-MIBI. Results:Blood-pool clearance of 99m Tc-CO-MIBI was modeled and found to be biexponential during 2 hours after injection. The pharmacokinetics conform to two-compartment with 436.36±54.77 ml/h of blood clearance (CL) and half lives T α(1/2 ))=l.46±0.13 min for the fast early clearance, T β(1/2) =97.3+20.51 min for the slow late clearance. The clearance kinetics were faster than 99m Tc-MIBI which of CL=25 8.76±27.88 ml/h, T α(1/2) =2.21±0.09 min, T β(1/2) =163±14.1 min, respectively. The time-radioactivity curves showed that the pulmonary uptake curves were the lowest, the hepatic uptake curves were above the hearts early but descending so quickly as to start bellowing the heart curves at about 40min which were significant difference of 99m Tc-MIBI. To the latter, the liver curves were above the myocardial uptake curves sustained over 2 hours period post injection. The heart uptake ID% of 99m Tc-CO-MIBI were more than that of 99m Tc-MIBI at 10, 30, 60, 90, 120 min. The heart-lung and heart-liver ratios were also significantly different. For 99m Tc-CO-MIBI, they were 3.18±0.08 and 1.05±0.05 by 40 min while 99m Tc-MIBI 2.87±0.11 and 0.70±0.05, respectively. The planar and SPECT imaging of excellent quality during 10 to 120 min demonstrated that 99m Tc-CO-MIBI was high absorbed initially by myocardium and quickly clearance from liver. The whole body image show that the radioactivity mostly removed to the gallbladder and the intestines either. We can obtain perfect myocardial image without liver activity disturbance in condition of no extra fatty diets Conclusions: The result of this study suggested that the single alkaline component 99m Tc-CO-MIBI solution had better pharmacokinetics properties and

  14. Field Testing of Feedforward Collective Pitch Control on the CART2 Using a Nacelle-Based Lidar Scanner

    International Nuclear Information System (INIS)

    Schlipf, David; Haizmann, Florian; Hofsäß, Martin; Cheng, Po Wen; Fleming, Paul; Scholbrock, Andrew; Wright, Alan

    2014-01-01

    This work presents the results from a field test of LIDAR assisted collective pitch control using a scanning LIDAR device installed on the nacelle of a mid-scale research turbine. A nonlinear feedforward controller is extended by an adaptive filter to remove all uncorrelated frequencies of the wind speed measurement to avoid unnecessary control action. Positive effects on the rotor speed regulation as well as on tower, blade and shaft loads have been observed in the case that the previous measured correlation and timing between the wind preview and the turbine reaction are accomplish. The feedforward controller had negative impact, when the LIDAR measurement was disturbed by obstacles in front of the turbine. This work proves, that LIDAR is valuable tool for wind turbine control not only in simulations but also under real conditions. Furthermore, the paper shows that further understanding of the relationship between the wind measurement and the turbine reaction is crucial to improve LIDAR assisted control of wind turbines

  15. Field Testing of Feedforward Collective Pitch Control on the CART2 Using a Nacelle-Based Lidar Scanner

    Science.gov (United States)

    Schlipf, David; Fleming, Paul; Haizmann, Florian; Scholbrock, Andrew; Hofsäß, Martin; Wright, Alan; Cheng, Po Wen

    2014-12-01

    This work presents the results from a field test of LIDAR assisted collective pitch control using a scanning LIDAR device installed on the nacelle of a mid-scale research turbine. A nonlinear feedforward controller is extended by an adaptive filter to remove all uncorrelated frequencies of the wind speed measurement to avoid unnecessary control action. Positive effects on the rotor speed regulation as well as on tower, blade and shaft loads have been observed in the case that the previous measured correlation and timing between the wind preview and the turbine reaction are accomplish. The feedforward controller had negative impact, when the LIDAR measurement was disturbed by obstacles in front of the turbine. This work proves, that LIDAR is valuable tool for wind turbine control not only in simulations but also under real conditions. Furthermore, the paper shows that further understanding of the relationship between the wind measurement and the turbine reaction is crucial to improve LIDAR assisted control of wind turbines.

  16. The Physical Clogging of the Landfill Leachate Collection System in China: Based on Filtration Test and Numerical Modelling

    Directory of Open Access Journals (Sweden)

    Yili Liu

    2018-02-01

    Full Text Available Clogging of the leachate collection system (LCS has been a common operation problem in municipal solid waste (MSW landfills in China, which can result in high water levels that threaten the safety of landfill operations. To determine the cause of failure in an LCS, raw leachate from a municipal solid waste transfer station was collected and the high content of particulate matter was characterized. Based on the parameters obtained in a filtration test, a numerical simulation was performed to estimate the influence of particle deposition on drainage system clogging. The results showed that LCSs were confronted with the risk of clogging due to the deposition of particulate matter resulting from the higher concentration of total suspended solids (TSS level > 2200 mg L−1 and larger particle size (>30% TSS particles > 15 μm in the leachate. On one hand, the non-woven geotextile, as the upper layer of the LCS, retained most particulate matter of large diameters, reducing its hydraulic conductivity to approximately 10−8 to 10−9 m s−1 after 1–2 years of operation and perching significant leachate above it (0.6–0.7 m. On the other hand, the geotextile prevented the gravel layer from physically clogging and minimized the leachate head above the bottom liner. Therefore, the role of geotextile should be balanced to optimize the LCS in MSW landfills in China.

  17. Pathogenic bacteria and heavy metals toxicity assessments in evaluating unpasteurized raw milk quality through biochemical tests collected from dairy cows

    Directory of Open Access Journals (Sweden)

    Hamid Iqbal

    2016-11-01

    Full Text Available Objective: To evaluate the hygienic quality by determining the presence of predominant pathogenic microbial contaminants (contagious or environmental and indiscriminate heavy metals contained in unpasteurized milk samples collected from cattle specie of cow. Methods: Raw milk samples were collected in October, 2014 from different regions of District Kohat, Khyber Pakhtunkhwa, Pakistan and cultured on the selective media plates according to the manufacturer instructions to observe pathogenic microbial flora and confirm it with relevant biochemical tests to specify bacterial specie. Results: Milk samples analyzed on MacConkey and nutrient agar media were found contaminated mostly with coliform, Staphylococcus aureus, Enterobacter aerogenes and Proteus vulgaris. Similarly, result of the heavy metals analysis performed using atomic absorption spectrophotometer flame photometry showed that raw milk contains heavy metals residues of lead and cadmium contents at higher levels while copper, zinc and chromium were observed lower than permissible limits whereas manganese within specified recommended values. Conclusions: Microbial contamination of milk and toxic metals is mainly accredited to the scrupulous unhygienic measures during processing of milk exhibiting a wide array of hazardous impacts on human health.

  18. Installation of Tc-99m generator manufacturing facilities

    International Nuclear Information System (INIS)

    Shin, B. C.; Choung, W. M.; Park, J. H.; Park, S. H.; Kim, S. J.; Park, K. B.

    2004-01-01

    For the characteristics of radiopharmaceuticals, the manufacturing facility should be complied with the radiation safety standards for operators as well as GMP (Good Manufacturing Practice) cleanness standards for production. We intensively modified the existing Radioisotope production facilities, which were installed only in radiation safety points of view, to meet cleanness criteria. And the concept of multi-barrier buffer zones was introduced to apply negative air pressure for hot cell with first priority and to continue relative positive air pressure for clean room. The manufacturing area for Tc-99m Generator can be entered only through a second change. The doors of each change area are interlocked to maintain air pressure differentials. The pass box for material transfer are also interlocked so that only one side may be opened at any one time to keep cleanness. Two door-type autoclave was installed crossing the wall between preparing room and aseptic room to keep cleanness after sterilization. Three lead hot cells were installed and final inspection including gamma survey test were performed. The clean room was installed and TAB for this facility was performed in order to acquire the necessary air flow. The filter bank for filtration of exhausted radiation air was installed and its efficiency test was performed. In this facility, radiation shielding utilities and manufacturing instruments were set up and their operating manuals were documented. Efficiency tests for every utilities and instruments were satisfied and the approval for use of the facilities was achieved from MOST (Ministry of Science and Technology). The Sam Young Unitech, the lessee of the facilities set up the equipment in the hot cell, which is needed to produce Tc-99m Generator, supported by IPPE in Russia. They are composing the systems complied with the guidelines and the regulations, and keep in contact to KFDA for acquiring its approval. It is expected to produce Tc-99m Generator within

  19. Use of 99mTc from a commercial 99Mo/9mTc generator as yield tracer for the determination of 99Tc at low levels

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Jensen, Mikael; Nielsen, Sven Poul

    2007-01-01

    The concentrations of Tc-99 and impurity radionuclides in the Tc-99m tracer solution obtained from a commercial Mo-99/Tc-99m generator were measured by gamma spectrometry and liquid scintillation counting. Mo-99 and Ru-103 were found in the Tc-99m eluate. A simple separation using two extra alumina...... cartridges was investigated to purify the eluate to obtain a suitable Tc-99m tracer with low Tc-99 concentration. The activity ratio of Tc-99/Tc-99m in the prepared Tc-99m solution is lower than 15 x 10(-9), which is higher than the theoretical ratio of less than 10 x 10(-9). The possible reason is discussed....... The Tc-99 in the 20 kBq spiked Tc-99m tracer was found to be less than 0.3mBq, which is lower than the detection limit of the radiometric method used for environmental samples. The purified Tc-99m eluate is used as yield tracer for the determination of low levels of Tc-99 in environmental samples. (c...

  20. ST-segment elevation induced by ergometric stress during myocardial perfusion test with {sup 99m}Tc-SESTAMIBI; Supradesnivel ST inducido por stress ergométrico durante el estudio de perfusión miocárdica con {sup 99m}Tc-SESTAMIBI

    Energy Technology Data Exchange (ETDEWEB)

    Pastore, F. A.; Fernández, C. C.; Giovaneti, A.; Malvar, M.; Abud, A.C., E-mail: franciscopastore@gmail.com [Hospital Interzonal De Agudos Eva Perón, Provincia de Buenos Aires (Argentina)

    2014-07-01

    ST-segment elevation provoked by the exercise test is a low prevalence response. Two clinical cases in which such behavior arose during the myocardial technetium-99m-Sestamibi SPECT test are described. Physiopathological considerations in correlation with the bibliography linked to the subject are made. (authors) [Spanish] El supradesnivel del segmento ST inducido por el test de ejercicio es una respuesta de baja prevalencia. Se descri¬ben dos casos clínicos, en los cuales, dicho comporta¬miento se presentó durante el estudio de perfusión mio¬cárdica con tecnecio-99m-Sestamibi SPECT. Se realizan consideraciones fisiopatológicas en corre¬lación con los antecedentes bibliográficos vinculados al tema. (autores)

  1. sup(99m)Tc-sucralfate scintigraphy and colonic disease

    International Nuclear Information System (INIS)

    George, A.; Merrick, M.V.; Palmer, K.R.; Millar, A.M.

    1987-01-01

    Sucralfate is an aluminium substituted disaccharide, binding at low pH to sites of ulceration in the gastrointestinal tract. Dawson et al (1985) reported that abdominal scans taken 12-24 hours after ingestion of sup(99m)Tc-sucralfate provide a range of normal appearances in healthy subjects and the pattern of ileal or colonic abnormalities in inflammatory bowel disease, surprising in view of the low binding affinity of sucralfate at ileonic pH. The authors have studied a series of 18 consecutive patients undergoing routine colonoscopy preceded by sup(99m)Tc-sucralfate scintigraphy. In vitro tests of isotope binding to parent molecule and absence of gastric mucosal uptake show that the disappointing results were not due to disruption of the sup(99m)Tc-sucralfate complex. It is suggested that labelled sucralfate attaches to luminal contents rather than adhering to mucosa, supported by the caecal 'hot spots' found in patients shown to have caecal pooling at colonoscopy and by observations that the one poorly prepared patient with pronounced faecal retention at time of endoscopy also had increased retention of radioactivity throughout the colon in the absence of mucosal abnormality. (U.K.)

  2. Sup(99m)Tc-sucralfate scintigraphy and colonic disease

    Energy Technology Data Exchange (ETDEWEB)

    George, A.; Merrick, M.V.; Palmer, K.R.; Millar, A.M.

    1987-09-05

    Sucralfate is an aluminium substituted disaccharide, binding at low pH to sites of ulceration in the gastrointestinal tract. Dawson et al (1985) reported that abdominal scans taken 12-24 hours after ingestion of sup(99m)Tc-sucralfate provide a range of normal appearances in healthy subjects and the pattern of ileal or colonic abnormalities in inflammatory bowel disease, surprising in view of the low binding affinity of sucralfate at ileonic pH. The authors have studied a series of 18 consecutive patients undergoing routine colonoscopy preceded by sup(99m)Tc-sucralfate scintigraphy. In vitro tests of isotope binding to parent molecule and absence of gastric mucosal uptake show that the disappointing results were not due to disruption of the sup(99m)Tc-sucralfate complex. It is suggested that labelled sucralfate attaches to luminal contents rather than adhering to mucosa, supported by the caecal 'hot spots' found in patients shown to have caecal pooling at colonoscopy and by observations that the one poorly prepared patient with pronounced faecal retention at time of endoscopy also had increased retention of radioactivity throughout the colon in the absence of mucosal abnormality. (U.K.).

  3. Clinical application of 99mTc-DTPA-HSA

    International Nuclear Information System (INIS)

    Kawamura, Yasuaki; Yamazaki, Junichi; Okuzumi, Ichio

    1989-01-01

    A newly developed blood pool imaging agent, Tc-99m DTPA-HSA (Tc-99m HSA-D), was clinically assessed in blood pool studies of patients with heart disease. Twenty mCi of Tc-99m HSA-D was iv injected to the patients. Similarly, conventional Tc-99m HSA was injected one week later for comparison. Blood counts of Tc-99m HSA-D were significantly higher than those of Tc-99m HSA at 30 minutes after iv injection (p<0.01) and at one, 3, and 6 hours (p<0.001). For the heart, liver, and lungs, sequential counts of Tc-99m HSA-D were also significantly higher than those of Tc-99m HSA. Free Tc-99m uptake in the stomach, thyroid gland, and kidneys was higher on Tc-99m HSA images than Tc-99m HSA-D images. Hepatic and pulmonary uptake of free Tc-99m that were visualized on Tc-99m HSA-D did not influence the diagnostic ability. None of the patients had clinical toxicity of Tc-99m HSA-D. The results indicate that Tc-99m HSA-D is a stable blood pool imaging agent. (Namekawa, K)

  4. Prediction of multiaxial fatigue life for notched specimens of titanium alloy TC4

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Z. R.; Li, Z. X. [Southeast University, Nanjing (China); Hu, X. T.; Song, Y. D. [Nanjing University, Nanjing (China)

    2016-05-15

    Both the proportional and nonproportional multiaxial fatigue tests were conducted on two kinds of notched specimens of titanium alloy TC4. The multiaxial fatigue critical area of notched specimen is considered as the location experiencing the maximum damage. It is unsatisfactory to predict the multiaxial fatigue life with the local stress and strain in the fatigue critical area. The critical distance concepts are employed in the multiaxial life prediction method for notched specimens. The proposed method was checked by the test data of TC4 notched specimens. The prediction results are almost within a factor of three scatter band of the test results.

  5. Current status of research and development of 99Mo/99mTc generator in Korea

    International Nuclear Information System (INIS)

    Park, U.J.; Lee, J.S.; Son, K.J.; Nam, S.S.; Kwak, S.I.; Han, H.S.

    2006-01-01

    To supply 99m Tc in stable and economical manner in Korea, a chromatographic generator has been under development at KAERI since late 1980's. The chromatographic type of technetium generator is preferred in hospital because it is more convenient and less time-restricted for applications. Hence, the demand of 99m Tc in medical applications is keep increasing. In Korea, there are more than 200 gamma cameras including SPECT in hospitals. For these applications, approximately 100 units/week of 99m Tc generators of which annual cost reached 3 million US dollars were required in 2002. Hence, the development of 99m Tc generators and technology of fission 99 Mo processing were started while installing the generator loading facility (GLF) at KAERI. This facility is currently on a trial run for the commercial production of 99m Tc generators and expected to produce more than 200 generators per week in 2004. For the fission 99 Mo production, an annulus U foil target was considered as the LEU target. The designed LEU target is being used for target manufacturing test and accident analysis. The develop gel type 99m Tc generators by using a poly zirconium complex (PZC) and alumina column, KAERI has cooperated with a Japanese company since late 1990's. In 2003, experimental studies for molybdate adsorption capacity and elution characteristics of the PZC samples from three different batches produced by Kaken Co. were carried out. (author)

  6. Studies on sup(99m)Tc-pertechnetate from the MEK solvent extraction generator

    International Nuclear Information System (INIS)

    Mohammad, R.; Moore, D.E.; Maddalena, D.J.; Boyd, R.E.

    1984-12-01

    Analysis by gas chromatography-mass spectrometry and high performance liquid chromatography has revealed organic residues in sup(99m)Tc-pertechnetate obtained from 99 Mo-molybdate by extraction, using the organic solvent methylethylketone (MEK). The organic residues have been identified as either (i) low molecular weight carbonyl compounds such as formaldehyde, acetaldehyde and acetone, presumably caused by the effects of γ-radiation on MEK, or (ii) condensation products resulting from the action of strong alkali on MEK during the extraction process. The quantities of organic residues varied from batch to batch of extracted pertechnetate; up to 40 μ mL -1 was found. When these compounds were tested, in rats, by addition to a pyrophosphate bone-seeking radiopharmaceutical, the tissue distribution was not significantly different from that in the control, which contained no added compound. Assay for 99 Tc in MEK-derived pertechnetate indicated up to 10 μg mL -1 of 99 Tc carrier. An assessment of the biological effect of 99 Tc carrier was obtained by (i) red blood cell labelling, where 6 ng mL -1 of 99 Tc was sufficient to reduce labelling efficiency; and (ii) pyrophosphate tissue distribution, where a significant effect was obtained in the presence of 10 μ mL -1 of 99 Tc carrier

  7. Preparation of the 99mTc-dextran lymphoscin tigraphic agent and its preliminary clinical application

    International Nuclear Information System (INIS)

    Lu Weiyue; You Dejian; Ma Yuanming; He Guangren; Zhang Wei; Tu Zhipei; Jin Bixia

    1991-01-01

    Dextran-70 was treated by gradient sedimentation, and that with a mean molecular weight of 105000 which was optimal for lymphatic system imaging rabbits was selected. Sn-Dextran kit was produced containing the above-mentioned dextran. Sn-Dextran kits can be stored at 4 deg C for 8 months. Its efficiency of labelling is more than 95%. The biodistribution, pharmacokinetics studies and lymphoscintigraphy in rabbits for 99m Tc-dextran showed: (1) high radioactivity in the popliteal nodes and very low redioactivity in other nontarget organs except kidneys through which it was excreted; (2) 99m Tc-dextran accumulated markedly and rapidly in lymphatic system. The lymph channels and nodes were well visualized in scintigrams; (3) 99m Tc-dextran cleared rapidly from the injection site. Radioactivity of 95% of the injected dose disappearing after 6.5h. Toxicity tests indicated that: 99m Tc-dextran is a drug of low toxicity and safe. Preliminary clinical applications of 99m Tc-dextran in 100 cases provided satisfactory results. The process of imaging usually took less than 1h after injection, and no side-effects occurred in any patient. In most cases, the results corresponded basically with the clinical diagnosis. Hence, 99m Tc-dextran is an ideal radiopharmaceutical that can be used for the visualization of the lymphatic system. It is recomminded for routine use in clincal practice

  8. The utility of quantitative 99mTc-GSA liver scintigraphy in the evaluation of hepatic functional reserve

    International Nuclear Information System (INIS)

    Shuke, Noriyuki; Aburano, Tamio; Nakajima, Kenichi

    1992-01-01

    Using data from 17 patients with liver cirrhosis and 3 patients with fatty liver, we have compared the utility of 3 hepatic imaging agents in the evalution of hepatic functional reserve. Evaluated here were 99m Tc-galactosyl human serum albumin (GSA) which is a new ligand for hepatic binding protein, 99m Tc-N-pyridoxyl-5-methyl tryptophan (PMT) of a hepatobiliary agent, and 99m Tc-Sn colloid. In each patient, we performed these 3 imaging studies within a week and also examined hepatic function tests (indocyanine green test, hepaplastin test, choline-esterase, etc). In each imaging study, serial images and dynamic data were obtained after the injection of 99m Tc-GSA (185 MBq/3 mg), 99m Tc-PMT (185 MBq), or 99m Tc-Sn colloid (185 MBq). Using the dynamic data obtained, we analyzed the liver kinetics of the 3 agents based on 1 compartment model with 3 parameters (hepatic clearance, hepatic excretion rate, non-specific volume of distribution). From fitting the liver and heart data to this model, three unknown parameters were determined. Patlak plot was also applied in order to estimate liver uptake rate. Both curve fitting and Patlak plot could determine appropriate parameters in every study. In 99m Tc-GSA, a nonlinear 3 compartment model was also applied in order to estimate hepatic blood flow, liver receptor density, and affinity of receptor-GSA binding separately. Using the parameters obtained, we analyzed the correlations between the parameters and the results of hepatic function tests. In all of the parameters, those obtained from 99m Tc-GSA imaging showed the most significant statistical correlation with the results of hepatic function tests. From the present results, 99m Tc-GSA imaging was concluded to be the best for evaluation of hepatic functional reserve. (author)

  9. Synthesis and Characterization of Tc(I) Carbonyl Nitrosyl Species Relevant to the Hanford Tank Waste: FY 2016 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Hall, Gabriel B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chatterjee, Sayandev [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Levitskaia, Tatiana G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Martin, Thibaut J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wall, Nathalie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Walter, Eric D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-24

    Among long-lived radioactive constituents in the Hanford tank waste, Tc presents a unique challenge in that it exists predominantly in the liquid phase, generally in the anionic form of pertechnetate, TcO4-, which is highly volatile at low-activity waste (LAW) vitrification melter temperatures and mobile in the Hanford site’s subsurface environment. The complex behavior of Tc under storage, treatment, and immobilization conditions significantly affects its management options, which to-date remain uncertain. In strongly alkaline environments, Tc exists as pertechnetate, TcO4- (oxidation state +7), and in the reduced forms (oxidation state < +7) collectively known as non-pertechnetate species. Pertechnetate is a well-characterized, anionic Tc species that can be removed from LAW by anion exchange or solvent extraction methods. There is no definitive information on the origin of the non-pertechnetate Tc species, nor is there a comprehensive description of their composition and behavior. It has been recently proposed that the non-pertechnetate species can comprise Tc(I) metal center and carbonyl or mixed carbonyl nitrosyl ligands stabilizing low-valent Tc. Recent work by our group has significantly expanded this previous work, generating a series of Tc(I) carbonyl compounds and demonstrating that they can be generated from reduction of TcO4- in the simulated Hanford tank waste in presence of CO at elevated temperature (Levitskaia et al. 2014). These results are consistent with the previous proposal that [Tc(CO)3]+ species can be present in the Hanford tank waste and suggest that the low Tc(I) oxidation state is stabilized by the π-accepting ability of the CO ligands. The continuation work has been initiated to develop model Tc carbonyl nitrosyl compounds and investigate their potential presence in the Hanford tank wastes. This report summarizes our to-date results.

  10. In situ Spectroscopic Analysis and Quantification of [Tc(CO)3]+ in Hanford Tank Waste.

    Science.gov (United States)

    Branch, Shirmir D; French, Amanda D; Lines, Amanda M; Soderquist, Chuck Z; Rapko, Brian M; Heineman, William R; Bryan, Samuel A

    2018-06-12

    The quantitative conversion of non-pertechnetate [Tc(CO)3]+ species in nuclear waste storage tank 241-AN-102 at the Hanford Site is demonstrated. A waste sample containing the [Tc(CO)3]+ species is added to a developer solution that rapidly converts the non-emissive species into a luminescent complex, which is detected spectroscopically. This method was first demonstrated using a [Tc(CO)3]+ sample non-waste containing matrix to determine a detection limit (LOD), resulting in a [Tc(CO)3]+ LOD of 2.20 × 10-7 M, very near the LOD of the independently synthesized standard (2.10 × 10-7 M). The method was then used to detect [Tc(CO)3]+ in a simulated waste using the standard addition method, resulting in a [Tc(CO)3]+ concentration of 1.89 × 10-5 M (within 27.7% of the concentration determined by β- liquid scintillation counting). Three samples from 241-AN-102 were tested by the standard addition method: (1) a 5 M Na adjusted fraction, (2) a fraction depleted of 137Cs, (3) and an acid-stripped eluate. The concentrations of [Tc(CO)3]+ in these fractions were determined to be 9.90 × 10-6 M (1), 0 M (2), and 2.46 × 10-6 M (3), respectively. The concentration of [Tc(CO)3]+ in the as-received AN-102 tank waste supernatant was determined to be 1.84 × 10-5 M.

  11. Studies on the porphine labeled with 99mTc-pertechnetate

    International Nuclear Information System (INIS)

    Ai-Yih Wang; Jiunn-Liang Lin; Wen-Chieh Lin

    2010-01-01

    The aim of this research is to use acetylacetonate as a 99m Tc chelating agent label with porphyrin and evaluate its radiochemical and biological characteristics. Stannous chloride was used as a reductant to determine the chemical and biological characterization of 99m Tc-complexes from labeling porphine (4',4'',4'''-(2lH,23H-Porphine-5,10,15,20-terayl)tetrakis-(benzoic acid), TPPB) with 99m Tc-pertechnetate. Instant thin layer chromatography (ITLC), size exclusion chromatography (SEC), paper electrophoresis, and UV/Vis spectrophotometry were used to evaluate chemical characterization. Finally, biodistribution and liver function tests were applied to evaluate biological characteristics. The results of this study show that the labeling efficiency of 99m Tc(acac)-TPPB was nearly 100% when using acetylacetone (acac) as a conjugator. Three major 99m Tc(acac)-TPPB complexes were separated by SEC, and all of them were hydrophilic. The UV-Vis spectra of 99m Tc(acac)-TPPB complexes closely resembled those of the TPPB, but the wave lengths of their peaks changed 430, 521, 556, 591 and 647 nm after complexation. The biodistribution study selected the liver as the target organ. The 99m Tc(acac)-TPPB complex may cause short-term liver injury. However, this injury can be repaired, and the reagent is quickly metabolized. Hence, the toxicity of the 99m Tc(acac)-TPPB complex is within an acceptable range, and making it a promising liver imaging agent. (author)

  12. Lung function declines in patients with pulmonary sarcoidosis and increased respiratory epithelial permeability to 99mTc-DTPA

    International Nuclear Information System (INIS)

    Chinet, T.; Dusser, D.; Labrune, S.; Collignon, M.A.; Chretien, J.; Huchon, G.J.

    1990-01-01

    Respiratory epithelial clearance of 99m Tc-DTPA (RC-Tc-DTPA) and pulmonary function tests (PFT) were determined at intervals of 6 or 12 months in 37 untreated, nonsmoking patients with sarcoidosis over a period of 6 to 36 months. PFT included the measurements of total lung capacity (TLC), vital capacity (VC), FEV1, and diffusing capacity for carbon monoxide. No difference was found between the respiratory clearance of 113m In-DTPA (2.25 +/- 1.00%/min) and RC-Tc-DTPA (2.29 +/- 1.11%/min) in eight patients with pulmonary sarcoidosis. Pulmonary function decreased 15% or more in at least 2 function tests during 11 follow-up periods, but it remained stable during 47 follow-up periods. In patients whose lung function deteriorated, RC-Tc-DTPA increased to 3.51 +/- 1.55%/min; in contrast, in patients whose lung function remained stable, regardless of the initial values, RC-Tc-DTPA was normal (1.00 +/- 0.50%/min; p less than 0.001). In eight patients who were treated with corticosteroids, RC-Tc-DTPA decreased from 3.48 +/- 1.31%/min to 1.56 +/- 0.64%/min (p less than 0.001), and PFT improved. We conclude that in nonsmokers with pulmonary sarcoidosis, increased RC-Tc-DTPA is not related to dissociation of 99mTc from DTPA, RC-Tc-DTPA is increased when pulmonary function decreases, and, when increased, RC-Tc-DTPA decreases with corticosteroid therapy

  13. Development of 99mTc extraction techniques from 99Mo by (n,γ) reaction

    International Nuclear Information System (INIS)

    Kimura, Akihiro; Hori, Naohiko; Tsuchiya, Kunihiko; Ishihara, Masahiro; Yamabayashi, Hisamichi; Tanase, Masakazu; Fujisaki, Saburo; Sato, Yuichi

    2010-11-01

    Investigation of production method of 99 Mo by (n, γ) reaction, where the processing is relatively simple and generating less amount of radioactive waste, is conducted in the Neutron Irradiation and Testing Reactor Center. The 99 Mo is adsorbed to highly efficient adsorbent PZC after neutron irradiation and 99m Tc is eluted. However, radioactivity concentration of the 99m Tc solution obtained from PZC column loaded with 99 Mo derived by (n, γ) method is lower than that obtained from alumina column with 99 Mo by (n, f) method due to extremely low specific activity of (n, f) 99 Mo. Therefore, it is necessary to develop technique for increasing the amount of 99 Mo and the 99m Tc solution of high radioactivity concentration (minimum: 1Ci/ cm 3 ). In this study, the preliminary fabrication tests using high density MoO 3 pellets were carried out to increase the production of 99 Mo. The method of concentrating 99m Tc solution through solvent extraction with MEK was investigated and a device for this concentration process was also developed. In the preliminary tests of the MoO 3 pellets, the pellets having high density were successfully fabricated by the SPS method. Additionally, it was ascertained that the pellets can be dissolved with 6M-NaOH solution completely. The test for 99 Mo adsorption followed by 99m Tc elution using PZC was carried out. As the result, amount of Mo adsorbed to 1g-PZC was about 250mg, and 99m Tc yield was about 80%. In the concentration test using Re solution instead of 99m Tc solution, it was ascertained that the concentration efficiency is higher than 80% of the theoretical value. A concentration device for 99m Tc solution could be realized based on the method employed in the present experiments. The outcomes of development of 99m Tc extraction techniques from 99 Mo by (n,γ) reaction was reviewed in this paper, and the contents were presented in the 3rd International Symposium on Material Test Reactors. (author)

  14. A study on 99mTc-macroaggregated albumin as lung imaging agent

    International Nuclear Information System (INIS)

    Xu Rongzhu; Fan Guangyu; Liu Yinmei; Bai Suzhen

    1990-01-01

    A method for the preparation of macroaggregated albumin (MAA) kits labelled with 99m Tc for lung scanning is described. The tween-80 is used as both dispersing agent and stable agent in order to raise uniformity and concentration of MAA particle size, which is between 10 to 100 μm. More than 80% particles are in the range of 10-60 μm. A millilitre MAA solution contains 5.3 x 10 6 particles. The lyophilized MAA kits are stable within eight months. The unlyophilized MAA kits are stable within 51 days. The radiochemical yield is >95% and the radiochemical purity is determined by paper chromatography. In addition, centrifuge method is used in combination with micro paper chromatography, in order to obtain the percentage of 99m Tc(IV) bound to the MAA, the percentage of unreduced 'free' 99m Tc(VII) and the percentage of reduced-hydrolyzed form of 99n Tc(IV). Blank centrifuge test of the 99m Tc(IV)-Sn colloid shows that about 85% 99m Tc(IV) is found in the supernatant solution. This method is simple and rapid. After eight hours the radiochemical purity of the labelled 99m Tc-MAA sample placed at 16 deg C and 22 deg C remains >95%. The organ distribution of LACA 18-26g mice meets the standard of the same product in the US pharmacopeia. The results of the study with rabbits by scanning with γ-camera indicate that the activity in the lung of the rabbit reaches a high level between 2-3 hours after injection. The toxic test and nonsterile and nonpyrogen test are very satisfactory and meet the standard of the Chinese pharmacopeia

  15. A new detection method of 99Tc by nuclear excitation

    International Nuclear Information System (INIS)

    Sekine, T.; Yoshihara, Kenji; Nemeth, Zs.; Lakosi, L.; Veres, A.

    1989-01-01

    A new nuclear excitation process, 99 Tc(γ,γ') 99m Tc reaction, was applied for the first time to radioactivation analysis of technetium. Bremsstrahlung irradiation of 99 Tc samples gave the reaction product 99m Tc which emits γ-ray easily measurable by a semiconductor detector. The production rate of 99m Tc per μg 99 Tc was linearly correlated with the flux of bremsstrahlung. The detection limit of 99 Tc was estimated to be nanogram order (0.63 Bq 99 Tc) under the optimum irradiation condition. Possible interference by 100 Ru(γ, p) 99m Tc reaction was also studied, which could be discriminated from the (γ,γ') reaction by simultaneously occurring 98 Ru(γ,p) 97 Ru reaction. (author) 17 refs.; 7 figs

  16. Method for the detection of Tc in seaweed samples coupling the use of Re as a chemical tracer and isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Mas, Jose Luis; Tagami, Keiko; Uchida, Shigeo

    2004-01-01

    Analysis of the artificial radionuclide 99 Tc in environmental samples requires a chemical separation due to its low concentration, and therefore the use of a chemical yield tracer is peremptory. From a practical viewpoint, Re can be used for this purpose, due to its chemical similarities with Tc. Thus, the use of a radioactive tracer for Tc recovery calculation can be avoided. However, results from a recent intercomparison exercise showed that using of Re as a chemical yield tracer appears to underestimate the Tc concentration relative to the result obtained with isotopes of Tc. In the present work, the methodology used to design a simple separation method for the measurement of 99 Tc in environmental samples is described. Tc recovery is estimated throughout the Re recovery calculation by the isotope dilution technique coupled with ICP-MS (ID-ICP-MS) technique. For chemical separation, a chromatographic resin is used. Interfering elements are removed using a resin washing step carefully designed to avoid any element fractionation between Re and Tc; the care taken in this step is of major importance to assure the equivalence of the chemical recoveries for both elements. Agreement is tested using five replicates of five seaweed samples. The average recoveries for 95m Tc and Re were 93±6 and 95±7%, respectively, those are within the uncertainty intervals for each other. The results explained here demonstrate the possibility of applying Re chemical recoveries to calculate the Tc concentrations with the advantage of not introducing systematic errors

  17. Preparation and quality control of 99m Tc-MDPA

    International Nuclear Information System (INIS)

    Bernardes, Dulcila M. Lessa; Castanheira, Claudia Elisabete; Castro, Jose Alberto de; Mengatti, Jair; Muramoto, Emiko; Pereira, Claudia Regina; Vicente, Irene

    2005-01-01

    Since the early 1970s a number of 99 mTc-phosphate compounds have been introduced for bone imaging. The three extensively studies diphosphonates are: 1-hydroxyethylidene diphosphonate (HEDP), methylene diphosphonate (MDP) and hydroxymethylene diphosphonate (HMDP or HDP) of which MDP and HDP are most commonly used in nuclear medicine. This report describes the routine production and quality control of MDP ('multidose') at IPEN-CNEN/SP, in lyophilized form for labeled with high activities of 99m Tc (9,250 MBq). The process was done under vacuum and low temperature in Super Modulyo -'Edwards' lyophilizator and each lyophilized vial contains: 5.0 mg of MDP; 1.0 mg SnCl 2 .H 2 O; 0.1mg ascorbic acid and 20.0 mg sodium pyrophosphate at pH = 6.0. The radiochemical purity was determined by thin layer chromatography system in Whatman 3MM paper (1 x 8 cm), using acetone and saline (0.9% NaCl) as solvents, respectively. Sterility and pyrogen tests were performed by the microbiology procedures outlined in the pharmacopoeias and by the 'in-vitro' Limulus test, respectively. Biological distribution in Wistar rats was evaluated in different organs (% dose / organ). The method was validated for routine production at Radiopharmacy Center, the radiochemical purities of 99m Tc-MDP ('multidose') was > 95%. The biological distribution in rats showed high uptake in bone tissue, and low activities in thyroid, liver and stomach. Sterility and pyrogen tests were negative in all the delivered lyophilized vials. (author)

  18. Data Collection and Harmonization in HIV Research: The Seek, Test, Treat, and Retain Initiative at the National Institute on Drug Abuse.

    Science.gov (United States)

    Chandler, Redonna K; Kahana, Shoshana Y; Fletcher, Bennett; Jones, Dionne; Finger, Matthew S; Aklin, Will M; Hamill, Kathleen; Webb, Candace

    2015-12-01

    Large-scale, multisite data sets offer the potential for exploring the public health benefits of biomedical interventions. Data harmonization is an emerging strategy to increase the comparability of research data collected across independent studies, enabling research questions to be addressed beyond the capacity of any individual study. The National Institute on Drug Abuse recently implemented this novel strategy to prospectively collect and harmonize data across 22 independent research studies developing and empirically testing interventions to effectively deliver an HIV continuum of care to diverse drug-abusing populations. We describe this data collection and harmonization effort, collectively known as the Seek, Test, Treat, and Retain Data Collection and Harmonization Initiative, which can serve as a model applicable to other research endeavors.

  19. Acceptability and usability of self-collected sampling for HPV testing among African-American women living in the Mississippi Delta.

    Science.gov (United States)

    Scarinci, Isabel C; Litton, Allison G; Garcés-Palacio, Isabel C; Partridge, Edward E; Castle, Philip E

    2013-01-01

    Human papillomavirus (HPV) DNA testing has been shown to be an effective approach to cervical cancer screening, and self-collection sampling for HPV testing could be a potential alternative to Pap test, provided that women who tested positive by any method get timely follow-up and care. This feasibility study examined acceptability and usability of self-collected sampling for HPV testing among African-American (AA) women in the Mississippi Delta to inform the development of interventions to promote cervical cancer screening in this population. The study consisted of two phases. Phase I consisted of eight focus groups (n = 87) with AA women to explore knowledge, attitudes, and beliefs about cervical cancer and HPV infection as well as acceptability of self-collected sampling for HPV testing. In phase II, we examined the usability of this technology through one discussion group (n = 9). The Health Belief Model guided data collection and analysis. Although participants perceived themselves as susceptible to cervical cancer and acknowledged its severity, there was a lack of knowledge of the link between HPV and cervical cancer, and they expressed a number of misconceptions. The most frequent barriers to screening included embarrassment, discomfort, and fear of the results. Women in both phases were receptive to self-collected sampling for HPV testing. All participants in the usability phase expressed that self-collection was easy and they did not experience any difficulties. Self-collection for HPV testing is an acceptable and feasible method among AA women in the Mississippi Delta to complement current cytology cervical cancer screening programs. Copyright © 2013 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  20. Can tumor uptake Tc-99m MDP

    International Nuclear Information System (INIS)

    Yang, Y.S.F.; Zeng, Z.J.; Yao, Y.M.; Shi, S.M.P.; Shi, S.Z.Y.

    2002-01-01

    Aim: To study a distribution of Tc-99m MDP in mice bearing tumor cell lines. Methods: The uptake of Tc-99m MDP was analyzed in seven human tumor cell lines (SPC-A1 adenocarcinoma of lung cancer, P37 Breast cancer, T24 Bladder cancer, SKOV2 Ovary carcinoma, Hela-229 Cervical carcinoma, Osteosarcoma, A375 Melanoma) and one mouse lung cancer cell line (Lewis). They were transplanted into 13, 4, 5, 5, 4, 5 athymic mice, 6 SCID nude mice and 4 C57 black mice, respectively. Approximately 10(7) cells of each cell line were injected subcutaneously into a right chest of mouse. After 5∼6 weeks, the Tc-99m MDP scintigraphy were determined 5-6 hours after i.v. injection of 74MBq in 0.05ml every mouse. Result: Biodistribution and tumor uptake MDP was different in the various cell types investigated. Region of interests (RIOs) placed on a small part of the tumor and horizontal copied to left chest or spine of mice in Tc-99m MDP imaging and the average count ratio (tumor to background ratio: T/B, tumor to spine ratio: T/NT) in each ROI was calculated. 13 nude mice bearing the adenocarcinoma (SPC-A1) were sacrificed and biodistribution was determined after Tc-99m MDP scintigraphy. Results were expressed as % injected dose/gram (%ID/g), mean±SD. T-ulcer=ulcer of tumor, T-round=surrounding of tumor, T-center=the center of tumor, Thor-sp=thoracic spine, Lum-ver=lumbar vertebra, LN=lymph node. Conclusions: Tumor can uptake Tc-99m MDP including adenocarcinoma. Higher uptake rate in the center tissue of tumor is than other part of tumor. It maybe connected with necrosis or fibrosis of tumor

  1. Production of gel 99mTc generators for Nuclear Medicine at the Nuclear Power Institute of China, Chengdu

    International Nuclear Information System (INIS)

    Boyd, R.E.

    1996-07-01

    The development and testing of the gel-type 99m Tc generator technology has been going on for several years at the Nuclear Power Institute of China. This generator type has already been licensed by the Ministry of Health. With the co-operation of the IAEA, under Model Project CPR/2/006,it is intended to upgrade and optimise the existing facility for large scale production and continue to improve the generator performance in terms of quality and reliability of its use in nuclear medicine. The expert mission objective was to carry out final laboratory tests to assess the performance of the gel- type 99m Tc, locally produced, as well as to assess the suitability of the corresponding 99m Tc eluate for nuclear medicine studies. In particular, the expert tested the suitability of the 99m Tc for the labelling of sensitive biomolecules and its general performance in a nuclear medicine service

  2. The evaluation of dobutamine 99mTc-MIBI myocardial perfusion imaging in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    He Qing; Qu Wanying; Gong Junhui; Zhou Ying

    1996-01-01

    The method and the clinical value of dobutamine stress test as a substitute for exercise test in 99m Tc-MIBI myocardial perfusion imaging was investigated. 40 Patients were intravenously infused with dobutamine through IVAC syringe pumps by incremental doses, and 99m Tc-MIBI was injected at the peak dobutamine heart rate. The myocardial imaging was then performed. The rest myocardial imaging was done after 48 hours. 30 of the 31 patients with coronary heart disease showed reversible perfusion defects in dobutamine 99m Tc-MIBI myocardial perfusion images and 7 of the 9 patients without coronary heart disease showed normal images. The sensitivity of this test was 96.8% and the specificity 77.8%. None of the studies was discontinued due to dobutamine side effect. Dobutamine 99m Tc-MIBI myocardial perfusion imaging is a safe and sensitive method in the diagnosis of coronary heart disease

  3. /sup 99m/Tc-labelled hepatobiliary radiopharmaceuticals

    International Nuclear Information System (INIS)

    Galli, G.; Maini, C.L.

    1986-01-01

    During the last 15 years many compounds labelled with /sup 99m/Tc have been proposed for use in cholescintigraphy. A short chronological list includes: toluidine blue, penicillamine, tetracycline, dihydrothioctic acid, mercaptoisubutyric acid, pyridoxals, pyridoxylideneaminates, carboxyl-hydroxyquinoline, substituted acetanilide iminodiacetates (so called IDAs), ethylenediamine-N, N-diacetate derivatives (such as sulfonyl-EDDA and benzoyl-EDDA), and orthoiodohippurate analogues. Among all these compounds the IDAs have been those most extensively used for basic and clinical research. A large series of IDA derivatives has been developed, and the properties of 33 of them have recently been tested

  4. Revision: quality control of 99mTc

    International Nuclear Information System (INIS)

    Alves, S.M.; Kabad, M.C.; Teixeira, G.J.; Sousa, C H.S.

    2015-01-01

    The radiopharmaceutical most commonly used in nuclear medicine is technetium-99m. Radiopharmaceuticals labeled with 99m Tc are the main agents for diagnosis, being used in the vast majority of procedures due to radionuclide characteristics. During its preparation impurities can be generated that make products with different qualities of the desired. In this paper were presented some of the factors that can interfere with radiopharmaceuticals and the tests used for quality assurance, certifying that the product is fit for purpose. It is up to nuclear medicine centers deploy a program to raise the quality of exams and increase patient safety. (author)

  5. Genetic Characterization of Trypanosoma cruzi DTUs in Wild Triatoma infestans from Bolivia: Predominance of TcI

    Science.gov (United States)

    Brenière, Simone Frédérique; Aliaga, Claudia; Waleckx, Etienne; Buitrago, Rosio; Salas, Renata; Barnabé, Christian; Tibayrenc, Michel; Noireau, François

    2012-01-01

    Background The current persistence of Triatoma infestans (one of the main vectors of Chagas disease) in some domestic areas could be related to re-colonization by wild populations which are increasingly reported. However, the infection rate and the genetic characterization of the Trypanosoma cruzi strains infecting these populations are very limited. Methodology/Principal Findings Of 333 wild Triatoma infestans specimens collected from north to south of a Chagas disease endemic area in Bolivia, we characterized 234 stocks of Trypanosoma cruzi using mini-exon multiplex PCR (MMPCR) and sequencing the glucose phosphate isomerase (Gpi) gene. Of the six genetic lineages (“discrete typing units”; DTU) (TcI-VI) presently recognized in T. cruzi, TcI (99.1%) was overdominant on TcIII (0.9%) in wild Andean T. infestans, which presented a 71.7% infection rate as evaluated by microscopy. In the lowlands (Bolivian Chaco), 17 “dark morph” T. infestans were analyzed. None of them were positive for parasites after microscopic examination, although one TcI stock and one TcII stock were identified using MMPCR and sequencing. Conclusions/Significance By exploring large-scale DTUs that infect the wild populations of T. infestans, this study opens the discussion on the origin of TcI and TcV DTUs that are predominant in domestic Bolivian cycles. PMID:22685616

  6. A Study on 99mTc-pertechnetate thyroid uptake in various thyroid disease

    International Nuclear Information System (INIS)

    Choi, Sung Jae; Min, Hae Sook; Koh, Chang Soon; Lee, Mun Ho

    1974-01-01

    The 99m Tc-pertechnetate thyroid uptake rates(20 min) were measured in 24 healthy normal subjects, 140 patients with nontoxic goiter and 98 patients with thyrotoxicosis who were treated at the Thyroid Clinic, Seoul National University Hospital, from August 1972 to August 1973. Diagnostic reliabilities and correlations between 99m TcO 4 -thyroid uptake rate (20 min) and other thyroid function tests were evaluated. The observed results were as follows:1) The 99m TcO 4 - thyroid uptake rates (20 min) in normal subjects, euthyroid group and hyperthyroid group were 4.1±0.9%, 5.2±1.8% and 29.7±10.6%. There was a significant difference between the mean of the euthyroid group and the mean of the hyperthyroid group and so differentiation between them can be easy. 2) In the diagnosis of hyperthyroidism, the reliabilities of 99m TcO 4 - thyroid uptake rate(20 min), 131 I thyroid uptake rate (24 hrs), serum T 3 resin uptake rate, serum T 4 and T 7 were 87.9-97.9%, 81.2-94.4%, 87.9-97.9%, 90.5-99.3% and 93.7-100%. 99m TcO 4 -thyroid uptake rate (20 min) is more accurate than 131 I thyroid uptake rate (24 hrs) in the diagnosis of hyperthyroidism. 3) 99m TcO 4 -thyroid uptake rate (20 min) was well correlated with 131 I thyroid uptake rate (24 hrs), serum T 3 resin uptake rate, serum T 4 and T 7 . Points in favor of 99m Tc are that it gives a small radiation dose to the thyroid, that tests can be repeated at the short interval, the study can be completed at a single patient visit and it is particularly well suited for the assessment of thyroid function in patients being treated with an antithyroid drug.

  7. Summary of Blast Shield and Material Testing for Development of Solid Debris Collection at the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Shaughnessy, D.A.; Gostic, J.M.; Moody, K.J.; Grant, P.M.; Lewis, L.A.; Hutcheon, I.D.

    2011-01-01

    The ability to collect solid debris from the target chamber following a NIF shot has application for both capsule diagnostics, particularly for fuel-ablator mix, and measuring cross sections relevant to the Stockpile Stewardship program and nuclear astrophysics. Simulations have shown that doping the capsule with up to 10 15 atoms of an impurity not otherwise found in the capsule does not affect its performance. The dopant is an element that will undergo nuclear activations during the NIF implosion, forming radioactive species that can be collected and measured after extraction from the target chamber. For diagnostics, deuteron or alpha induced reactions can be used to probe the fuel-ablator mix. For measuring neutron cross sections, the dopant should be something that is sensitive to the 14 MeV neutrons produced through the fusion of deuterium and tritium. Developing the collector is a challenge due to the extreme environment of the NIF chamber. The collector surface is exposed to a large photon flux from x-rays and unconverted laser light before it is exposed to a debris wind that is formed from vaporized material from the target chamber center. The photons will ablate the collector surface to some extent, possibly impeding the debris from reaching the collector and sticking. In addition, the collector itself must be mechanically strong enough to withstand the large amount of energy it will be exposed to, and it should be something that will be easy to count and chemically process. In order to select the best material for the collector, a variety of different metals have been tested in the NIF chamber. They were exposed to high-energy laser shots in order to evaluate their postshot surface characterization, morphology, degree of melt, and their ability to retain debris from the chamber center. The first set of samples consisted of 1 mm thick pieces of aluminum that had been fielded in the chamber as blast shields protecting the neutron activation diagnostic. Ten

  8. Simple determination of 99Tc in radioactive waste using Tc extraction disk and imaging plates

    International Nuclear Information System (INIS)

    Kameo, Y.; Katayama, A.; Hoshi, A.; Haraga, T.; Nakashima, M.

    2010-01-01

    A simple method was developed for determination of 99 Tc in low-level radioactive waste: Technetium-99 retained by a solid phase extraction disk was directly measured with imaging plates system. It was found that more than 97% of Tc were retained by the disk from a solution of pH 2 to 12, whereas depth profile of Tc in the disk, which greatly influences the counting efficiency, depended on solution pH. The present method was successfully applied to actual radioactive liquid waste samples arising from nuclear research facilities.

  9. Technetium removal column flow testing with alkaline, high salt, radioactive tank waste

    International Nuclear Information System (INIS)

    Blanchard, D.L. Jr.; Kurath, D.E.; Golcar, G.R.; Conradson, S.D.

    1996-01-01

    This report describes two bench-scale column tests conducted to demonstrate the removal of Tc-99 from actual alkaline high salt radioactive waste. The waste used as feed for these tests was obtained from the Hanford double shell tank AW-101, which contains double shell slurry feed (DSSF). The tank sample was diluted to approximately 5 M Na with water, and most of the Cs-137 was removed using crystalline silicotitanates. The tests were conducted with two small columns connected in series, containing, 10 mL of either a sorbent, ABEC 5000 (Eichrom Industries, Inc.), or an anion exchanger Reillex trademark-HPQ (Reilly Industries, Inc.). Both materials are selective for pertechnetate anion (TcO 4 - ). The process steps generally followed those expected in a full-scale process and included (1) resin conditioning, (2) loading, (3) caustic wash to remove residual feed and prevent the precipitation of Al(OH) 3 , and (4) elution. A small amount of Tc-99m tracer was added as ammonium pertechnetate to the feed and a portable GEA counter was used to closely monitor the process. Analyses of the Tc-99 in the waste was performed using ICP-MS with spot checks using radiochemical analysis. Technetium x-ray absorption spectroscopy (XAS) spectra of 6 samples were also collected to determine the prevalence of non-pertechnetate species [e.g. Tc(IV)

  10. Modelling 99Tc concentrations in Fucus vesiculosus from the north-east Irish Sea

    International Nuclear Information System (INIS)

    Nawakowski, Claire; Nicholson, Michael D.; John Kershaw, Peter; Leonard, Kinson S.

    2004-01-01

    In 1994 there were substantial increases in the quantity of 99 Tc discharged into the north-east Irish Sea from BNFL Sellafield (UK), concomitant with improvements in waste treatment procedures. As a consequence, the concentration of 99 Tc observed in seawater and biota samples, taken from the Irish Sea coastline, increased significantly. Elevated concentrations were also reported in Dutch, Danish, Norwegian, Swedish and Arctic waters in subsequent years. In the present study a simple numerical model was developed and applied to time-series data of 99 Tc concentrations in the brown seaweed Fucus vesiculosus, collected from three UK sites in the vicinity of Sellafield (St. Bees, Heysham, Port William). The model considered site-specific scaling effects, lag times, previous discharge history and potential seasonal variation in uptake. In general, there was a good fit between predicted and observed concentrations, but the degree of uncertainty varied inversely with the frequency of sampling. We did not observe a significant seasonal variation. The modelled lag times to the three sites were consistent with transport times based on observations of the water column distribution of 99 Tc. The model was applied to a variety of discharge scenarios, reflecting current discussion on the future management of 99 Tc releases. Concentrations in Fucus reached asymptotic values in 3-10 years, depending on the scenario and sampling site under consideration

  11. Soil-to-Plant Transfer Factors of {sup 99}Tc for Korean Major Upland Crops

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Ho; Lim, Kwang Muk; Jun, In; Keum, Dong Kwon [Korea Atomic Energy Reserach Institute, Daejeon (Korea, Republic of)

    2011-12-15

    In order to investigate the soil-to-plant transfer factor (TF) of {sup 99}Tc for Korean major upland crops (soybean, radish and Chinese cabbage), pot experiments were performed in a greenhouse. Soils were collected from four upland fields (two for soybean and two for radish and Chinese cabbage) around Gyeongju radioactive-waste disposal site. Three to four weeks before sowing, dried soils were mixed with a {sup 99}Tc solution and the mixtures were put into pots and irrigated. TF values were expressed as the ratios of the {sup 99}Tc concentrations in plants (Bq kg{sup -1}-dry or fresh) to those in soils (Bq kg{sup -1}-dry). There was no great difference in the TF value between soils. The TF values for soybean seeds were extremely lower than those for the straws, indicating a very low mobility of {sup 99}Tc to seeds. As representative TF values of{sup 99}Tc,1.8 X 10{sup -1}, 1.2 X 10{sup 1}, 3.2 X 10{sup 2} and 1.3 X 10{sup 2} (for dry plants), arithmetic means for two soils, were proposed for soybean seeds, radish roots, radish leaves and Chinese cabbage leaves, respectively. In the case of the vegetables, proposals for fresh plants were also made. The proposed values are not sufficiently representative so successive updates are needed.

  12. Bcl-2 overexpression prevents 99mTc-MIBI uptake in breast cancer cell lines

    International Nuclear Information System (INIS)

    Aloj, Luigi; Zannetti, Antonella; Caraco, Corradina; Del Vecchio, Silvana; Salvatore, Marco

    2004-01-01

    We have previously shown a correlation between the absence of technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) uptake and overexpression of the anti-apoptotic protein Bcl-2 in human breast carcinoma. To establish a direct cause-effect relationship between Bcl-2 overexpression and reduced 99m Tc-MIBI uptake, MCF-7 and T47D breast cancer cell lines were stably transfected with the human Bcl-2 gene to increase intracellular protein levels and tested for 99m Tc-MIBI uptake. All clones overexpressing Bcl-2 showed a dramatic reduction of 99m Tc-MIBI uptake as compared with mock transfected control cells. Tracer uptake was promptly and partially restored by induction of apoptosis with staurosporine treatment. After 4.5 h of staurosporine treatment, a tenfold increase in 99m Tc-MIBI uptake was observed in treated as compared with untreated Bcl-2 overexpressing cells. Our findings provide a rational basis for the development of an in vivo test to detect Bcl-2 overexpression in human tumours. (orig.)

  13. Evaluation of Tc-99M dextran as a useful agent for peripheral lymphoscintigraphy

    International Nuclear Information System (INIS)

    Farzana Kousar; Muhammad Numair Younis; Shabana Saeed; Mustanser Jehangir; Saeeda Asghar

    2004-01-01

    Peripheral lymphoscintigraphy is known for its great academic value and more importantly, may contribute to supporting the accuracy of clinical diagnosis and assessment of lymphedema treatment. The main aim of this study was to evaluate the 99m Tc dextran as peripheral lymphoscintigraphic agent and its validation in recognizing different lymphatic patterns in normal and edematous limbs. Methods: Peripheral lymphoscintigraphy was performed in 24 patients (mean age 43.9 ± 11 years) using 99m Tc dextran (molecular weight 150,000 and 250,000) as radiotracer. 37 MBq (1 mCi) 99m Tc dextran (PINSCANTM) was injected intradermally in the first web space of the hand or foot of both limbs. 30 minutes sequential dynamic and static imaging was done. Delayed static images were taken at one hour and then three hours post injection. Results: Only qualitative interpretation was done. Different lymphatic patterns were observed in normal population as well as in control and edematous limbs. Results were further analysed using chi square test, paired and unpaired student t test at the confidence level 0.05. All mean values were given with one standard deviation. Visual and statistical analysis showed good clinical correlation. These results were also compared favourably with 99m Tc HSA lymphoscintigraphic findings available in literature. Conclusion: 99m Tc dextran is a promising agent for peripheral lymphoscintigraphy. (authors)

  14. 99Tc in seawater in the West Spitsbergen Current and adjacent areas

    International Nuclear Information System (INIS)

    Gerland, Sebastian; Lind, Bjoern; Dowdall, Mark; Karcher, M.; Kolstad, Anne Kathrine

    2003-01-01

    99 Tc levels were measured in seawater samples collected between 2000 and 2002 in the West Spitsbergen Current (WSC) and along the western coast of Svalbard or Spitzbergen and compared with available oceanographic 3-D modelling results for the late 1990s. Additional data from related regions are also presented in order to support the data interpretation. The seawater in the Arctic fjord Kongsfjorden on the western coast of Svalbard is influenced by the WSC, as shown by the 99 Tc levels in surface water. By means of the WSC, 99 Tc reaches the Eastern Fram Strait, where one branch of the WSC turns west into the East Greenland Current (EGC), and another branch continues northwards into the Arctic Ocean. Surface seawater collected in the central part of the WSC during a cruise on board the R/V 'Polarstern' in the summer of 2000, showed higher levels of 99 Tc than samples measured in Kongsfjorden in the spring of 2000. However, all levels measured in surface water are of the same order of magnitude. Data from sampling of deeper water in the WSC and EGC provide information pertaining to the lateral distribution of 99 Tc. In all vertical profiling surveys (conducted in spring and summer), the highest levels of 99 Tc were found in surface water. Comparison with oceanographic 3-D modelling indicates both significant seasonal variations in the lateral stratification of the WSC and variations with depth over shorter vertical distances. This information can be applied in sampling strategies, environmental monitoring, long-range transport of pollutants and physical oceanography

  15. Process modifications of obtaining Tc-99m by solvent extraction

    International Nuclear Information System (INIS)

    Leon, A.; Verdera, S.

    1978-01-01

    This paper describes a modification in the process to obtaining Tc-99m by the extraction method of solvent from Mo-99 produced by irradiation. Tc-99m is considered an ideal radionuclide for medical and biological applications

  16. Cervical Cancer Screening Preferences Among Trans-Masculine Individuals: Patient-Collected Human Papillomavirus Vaginal Swabs Versus Provider-Administered Pap Tests.

    Science.gov (United States)

    McDowell, Michal; Pardee, Dana J; Peitzmeier, Sarah; Reisner, Sari L; Agénor, Madina; Alizaga, Natalie; Bernstein, Ida; Potter, Jennifer

    2017-08-01

    Trans-masculine (TM, i.e., persons who have a masculine spectrum gender identity, but were assigned female sex at birth) individuals face disparities in cervical cancer screening rates compared to cisgender women. Some unique barriers to screening in this population are specific to Pap tests. Introduction of self-collected frontal (i.e., vaginal) swabs for human papillomavirus (HPV) testing as a screening strategy may obviate these barriers. This study elucidates cervical cancer screening preferences among TM individuals. TM individuals participated in in-depth interviews (n = 31) and online surveys (n = 32) to explore perceptions and experiences regarding cervical cancer screening, including the acceptability of self-collected frontal HPV swabs for cervical cancer screening compared to provider-administered Pap tests. Provider-collected frontal HPV swab acceptability was also explored. Most TM individuals (94% in-person and 91% online participants) preferred either the self- or provider-collected frontal HPV swab to the Pap test. Participants perceived self- and provider-collected frontal HPV swabs to be less invasive, provoke less gender discordance, and promote a greater sense of agency compared to Pap tests. However, some participants expressed concern about HPV swab accuracy and, regarding the self-collected swab, discomfort about the need to engage with genitals they may not want to acknowledge. Individuals who reported positive provider relationships found Pap tests and provider-collected frontal swabs more acceptable than those who did not. Frontal HPV swabs have the potential to promote regular cervical cancer screening among TM individuals and to narrow screening disparities. Work is ongoing to establish swab accuracy and develop shared decision-making tools.

  17. MIBI-99mTc mammary scintigraphy

    International Nuclear Information System (INIS)

    Mayosky, Maria C.; Parma, Elvira P.; Armesto, Amparo M.; Zarlenga, Ana C.; Cresta, Carlos; Azar, Maria E.; Noblia, Cristina

    1999-01-01

    121 patients suspected of breast cancer were studied with MIBI- 99m Tc to evaluate the suitability of the mammary scintigraphy in patients with doubtful cancer diagnosis.The results show 93 % sensitivity and 95 % specificity and indicate the usefulness of this procedure to increase the accuracy of the diagnosis

  18. Tc Generator Development: Up-to-Date Tc Recovery Technologies for Increasing the Effectiveness of Mo Utilisation

    Directory of Open Access Journals (Sweden)

    Van So Le

    2014-01-01

    Full Text Available A review on the Mo sources available today and on the Tc generators developed up to date for increasing the effectiveness of Mo utilisation is performed in the format of detailed description of the features and technical performance of the technological groups of the Mo production and Tc recovery. The latest results of the endeavour in this field are also surveyed in regard of the technical solution for overcoming the shortage of Mo supply. The technological topics are grouped and discussed in a way to reflect the similarity in the technological process of each group. The following groups are included in this review which are high specific activity Mo: the current issues of production, the efforts of more effective utilisation, and the high specific activity Mo-based Tc generator and Tc concentration units; low specific activity Mo: the Mo production based on neutron capture and accelerators and the direct production of Tc and the methods of increasing the specific activity of Mo using Szilard-Chalmers reaction and high electric power isotopic separator; up-to-date technologies of Tc recovery from low specific activity Mo: the solvent extraction-based Tc generator, the sublimation methods for Mo/Tc separation, the electrochemical method for Tc recovery, and the column chromatographic methods for Tc recovery. Besides the traditional Tc-generator systems, the integrated Tc generator systems (Tc generator column combined with postelution purification/concentration unit are discussed with the format of process diagram and picture of real generator systems. These systems are the technetium selective sorbent column-based generators, the high Mo-loading capacity column-based integrated Tc generator systems which include the saline-eluted generator systems, and the nonsaline aqueous and organic solvent eluent-eluted generator systems using high Mo-loading capacity molybdategel and recently developed sorbent columns. Tc concentration methods used in the

  19. Enhanced inhibitory synaptic transmission in the spinal dorsal horn mediates antinociceptive effects of TC-2559

    Science.gov (United States)

    2011-01-01

    Background TC-2559 is a selective α4β2 subtype of nicotinic acetylcholine receptor (nAChR) partial agonist and α4β2 nAChR activation has been related to antinociception. The aim of this study is to investigate the analgesic effect of TC-2559 and its underlying spinal mechanisms. Results 1) In vivo bioavailability study: TC-2559 (3 mg/kg) had high absorption rate in rats with maximal total brain concentration reached over 4.6 μM within first 15 min after administration and eliminated rapidly with brain half life of about 20 min after injection. 2) In vivo behavioral experiments: TC-2559 exerts dose dependent antinociceptive effects in both formalin test in mice and chronic constriction injury (CCI) model in rats by activation of α4β2 nAChRs; 3) Whole-cell patch-clamp studies in the superficial dorsal horn neurons of the spinal cord slices: perfusion of TC-2559 (2 μM) significantly increased the frequency, but not amplitude of spontaneous inhibitory postsynaptic currents (sIPSCs). The enhancement of sIPSCs was blocked by pre-application of DHβE (2 μM), a selective α4β2 nicotinic receptor antagonist. Neither the frequency nor the amplitude of spontaneous excitatory postsynaptic currents (sEPSCs) of spinal dorsal horn neurons were affected by TC-2559. Conclusions Enhancement of inhibitory synaptic transmission in the spinal dorsal horn via activation of α4β2 nAChRs may be one of the mechanisms of the antinociceptive effects of TC-2559 on pathological pain models. It provides further evidence to support the notion that selective α4β2 subtype nAChR agonist may be developed as new analgesic drug for the treatment of neuropathic pain. PMID:21816108

  20. Role of /sup 99/mTc pertechnetate uptake in the evaluation of thyroid function

    Energy Technology Data Exchange (ETDEWEB)

    Sucupira, M.S.; Camargo, E.E.; Nickoloff, E.L.; Alderson, P.O.; Wagner, H.N. Jr.

    1983-01-01

    To investigate the usefulness of the 20 min /sup 99/mTc-pertechnetate uptake test, the records of 246 consecutive patients were reviewed. Of these, 192 patients (151 females, 41 males; 10 weeks to 78 years) had at least one year clinical follow-up or a confirmed diagnosis by biopsy or surgery and were included in our study. In these patients, the /sup 99/mTc pertechnetate uptake and hormonal values (T3 resin uptake, T4 RIA, T-index) were obtained. These results were then compared to the clinical diagnosis at the time of the uptake and one year later. All patients received an i.v. injection of 5 mCi of /sup 99/mTc pertechnetate. Imaging was performed using a pinhole collimator and a scintillation camera interfaced to a computer. Regions of interest for the thyroid and the background were used to calculate the 20 min /sup 99/mTc pertechnetate uptake as a percentage of the injected dose. /sup 99/mTc uptake and hormonal values were confirmatory in 158 patients (82.3%): 138 were euthyroid, 18 were hyperthyroid and 2 were hypothyroid. In 29 other patients (15.1%) the pertechnetate uptake provided useful additional information and helped to identify Hashimoto's thyroiditis (8 patients); thyroid suppression by exogenous iodide, steroids or T4 (7 patients); overtreated hyperthyroidism (1 patient); persistent hyperthyroidism (5 patients); different stages of Grave's disease (4 patients); and toxic nodular goiter (4 patients). The /sup 99/mTc uptake was misleading in 5 euthyroid patients (2.6%). We have found the /sup 99/mTc pertechnetate uptake a useful adjunct to measurement of hormonal levels in patients with suspected thyroid disease.

  1. Emission of Tc-99 from nuclear facilities

    International Nuclear Information System (INIS)

    Luxenburger, H.J.; Schuettelkopf, H.; Bohn, B.

    1984-11-01

    No noticeable Tc-activities are emitted from nuclear power stations. The emissions with the gaseous effluents exceed but rarely the detection limit of 25 nCi/h. Likewise, the emission with the liquid effluents remains below the detection limit of about 0.5 nCi/m 3 . Neither can a remarkable emission be recorded from the facilities of the Central Decontamination Services Department (HDB) of KfK. The emissions from the evaporation system for low level solutions and from the evaporation system for low level solutions and from the incineration facility for solid wastes do not exceed or rarely exceed to a minor extent the detection limit of 0.3 pCi/m 3 waste air. Also with the liquid effluents only minor Tc-amounts are discharged of 0.3 nCi/m 3 at the maximum. In the distillate of the medium level solutions discharged from the Karlsruhe Reprocessing Plant (WAK) to HDB as so-called tritiated water 2 nCi/m 3 Tc-99 at the maximum are contained. Only in the gaseous effluents from the evaporation system for medium level solutions emissions of up to 14 pCi/m 3 can be detected. The detection limits are almost permanently exceeded by the gaseous effluents from WAK. Small amounts of Tc-99 of 7 pCi/m 3 exhaust air at the maximum are released to the environment. However, the amount of Tc accumulated over the sampling period is insignificant from the radioecological point of view. (orig./HP) [de

  2. Occurrence and behaviour of Tc in the environment

    International Nuclear Information System (INIS)

    Luxenburger, H.J.; Schuettelkopf, H.

    1984-08-01

    A literature research was performed about the occurence and the behaviour of Tc in the environment. About 3600 publications, published between 1925 und 1983, were evaluated. The actual knowledge about Tc in the environment within extended regions is fragmentary. A lot of necessary informations about the behaviour of Tc in the environment are lacking completely. (orig.) [de

  3. Tc Chemistry in HLW: Role of Organic Complexants

    International Nuclear Information System (INIS)

    Hess, Nancy S.; Conradsen, Steven D.

    2003-01-01

    Tc complexation with organic compounds in tank waste plays a significant role in the redox chemistry of Tc and the partitioning of Tc between the supernatant and sludge components in waste tanks. These processes need to be understood so that strategies to effectively remove Tc from high-level nuclear waste prior to waste immobilization can be developed and so that long-term consequences of Tc remaining in residual waste after sludge removal can be evaluated. Only limited data on the stability of Tc-organic complexes exists and even less thermodynamic data on which to develop predictive models of Tc chemical behavior is available. To meet these challenges we are conducting a research program to study to develop thermodynamic data on Tc-organic complexation over a wide range of chemical conditions. We will attempt to characterize Tc-speciation in actual tank waste using state-of-the-art analytical organic chemistry, separations, and speciation techniques to validate our model. On the basis of such studies we will develop credible model of Tc chemistry in HLW that will allow prediction of Tc speciation in tank waste and Tc behavior during waste pretreatment processing and in waste tank residuals

  4. Mismatched uptake of Tc-99m-ECD and Tc-99m-HMPAO in subacute cerebral infarction: Tc-99m-ECD for viability and Tc-99m-HMPAO for flow restoration

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. S.; Hyun, I. Y.; Kim, S. K. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)] [and others

    1997-07-01

    Tc-99m-HMPAO reflects tissue perfusion but Tc-99m-ECD uptake is affected by tissue viability in addition to tissue perfusion which the varied state of cellular retention of Tc-99m-ECD reflects. Luxuriously perfused area on Tc-99m-HMPAO SPECT implies that this cortex was already reperfused either spontaneously or after thrombolysis and that accompanied paralysis of vascular reactivity in those zones warms progressive deterioration. We tried to find out if we can use sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT to reveal cortical perfusion and severity and range of risky areas of cerbral cortex despite reperfusion in sub-acute infarction. In 13 patients (M ; F =7 : 6, mean age 57 (range: 26-84)) with cortical (n=12) and basal ganglia infarction (1), we performed sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT at the same position. At first, 555 MBq of Tc-99m-ECD was injected and imaged and then 1110 MBq of Tc-99m-HMPAO was injected again and imaged with the patients in situ, and the first image (Tc-99m-ECD) and the subtracted image (2nd- 1st : Tc-99m-HMPAO) were compared slice by slice. Study was done from 3 days to 31 days (16{+-}9) after ictus. Tc-99m-ECD uptake was always less than or equal to Tc-99m-HMPAO uptake at the lesion in all cases. Luxury perfusion was prominent in four patients. Mismatched uptake was found in 10 patients. Severity of mismatch showed diverse spectrum and was ranged from total middle cerebral artery territory (1 case) to peripheral thin zones around infarction (2 cases). The other 7 showed intermediate amount of tissues with mismatch , i.e., Tc-99m-ECD defects where Tc-99m-HMPAO uptake is in part increased, normal or decreased. Upon discharge, patients having more uptake with Tc-99m-ECD predicted improvement. Patients having mismatched uptake went dichotomous way. In conclusion, Tc-99m-ECD/Tc-99m-HMPAO sequential SPECT is feasible and reveal both tissue perfusion (Tc-99m-HMPAO ) and discrepant Tc-99m-ECD uptake probably reflecting viability in acute

  5. Microstructure and Properties of Laser Additive Manufacturing TC Bearing

    Directory of Open Access Journals (Sweden)

    YANG Jiao-xi

    2016-07-01

    Full Text Available In order to solve the problem of uneven wear of TC bearing that conventional method brought and improve its service life,wear-resistant coating was fabricated on the surface of steel parts matrix with the method of laser additive manufacture. The Cr3C2/Fe based alloy was deposited by laser cladding technique on the inner-sleeve cylindrical and outer-sleeve bore of TC bearing with two different process parameters. The high-performance coating was obtained respectively, of cracks free,no pores and with good metallurgical quality. The morphology of the laser cladding coating was observed by scanning electronic microscope (SEM,the composition was analyzed by EDS,the phase transformation was characterized by XRD. The wear resistance,corrosion resistance and hardness of the laser cladding layer were tested by friction and wear tester,salt spray test chamber and digital micro-hardness tester respectively. The results show that the average micro-hardness of composite coating is HV700. The wear resistance of the composite coating is about 3 times as much as the Ni-based alloy. The corrosion resistance is close to 316L stainless steel.

  6. (99m)Tc-labeled gastrins of varying peptide chain length: Distinct impact of NEP/ACE-inhibition on stability and tumor uptake in mice.

    Science.gov (United States)

    Kaloudi, Aikaterini; Nock, Berthold A; Lymperis, Emmanouil; Krenning, Eric P; de Jong, Marion; Maina, Theodosia

    2016-06-01

    In situ inhibition of neutral endopeptidase (NEP) has been recently shown to impressively increase the bioavailability and tumor uptake of biodegradable gastrin radioligands. Furthermore, angiotensin converting enzyme (ACE) has been previously shown to cleave gastrin analogs in vitro. In the present study, we have assessed the effects induced by single or dual NEP/ACE-inhibition on the pharmacokinetic profile of three (99m)Tc-labeled gastrins of varying peptide chain length: [(99m)Tc]SG6 ([(99m)Tc-N4-Gln(1)]gastrin(1-17)), [(99m)Tc]DG2 ([(99m)Tc-N4-Gly(4),DGlu(5)]gastrin(4-17)) and [(99m)Tc]DG4 ([(99m)Tc-N4-DGlu(10)]gastrin(10-17)). Mouse blood samples were collected 5min after injection of each of [(99m)Tc]SG6/DG2/DG4 together with: a) vehicle, b) the NEP-inhibitor phosphoramidon (PA), c) the ACE-inhibitor lisinopril (Lis), or d) PA plus Lis and were analyzed by RP-HPLC for radiometabolite detection. Biodistribution was studied in SCID mice bearing A431-CCK2R(+/-) xenografts at 4h postinjection (pi). [(99m)Tc]SG6 or [(99m)Tc]DG4 was coinjected with either vehicle or the above described NEP/ACE-inhibitor regimens; for [(99m)Tc]DG2 control and PA animal groups were only included. Treatment of mice with PA induced significant stabilization of (99m)Tc-radiotracers in peripheral blood, while treatment with Lis or Lis+PA affected the stability of des(Glu)5 [(99m)Tc]DG4 only. In line with these findings, PA coinjection led to notable amplification of tumor uptake of radiopeptides compared to controls (PTc]DG4 profited by single Lis (2.06±0.39%ID/g vs 0.99±0.13%ID/g in controls) or combined Lis+PA coinjection (8.91±1.61%ID/g vs 4.89±1.33%ID/g in PA-group). Furthermore, kidney uptake remained favourably low and unaffected by PA and/or Lis coinjection only in the case of [(99m)Tc]DG4 (Tc-radioligands based on different-length gastrins. Truncated [(99m)Tc]DG4 exhibited overall the most attractive profile during combined NEP/ACE-inhibition in mouse models, providing new

  7. Study on the metabolic characteristics of renal imaging agent 99mTc-PAHIDA with tracer experiment

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Wang Liuyi; Lun Mingyue

    1995-01-01

    Tracer experiment showed that 99m Tc-PAHIDA was distributed predominantly in kidney. The distribution in other tissue was in the following descending order: heart, gastrointestinal tract, liver, spleen, muscle, adipose tissue, testes, and brain. The smaller the intravenous dose, the lower the proportion of the drug was combined to plasma protein and the more the drug was distributed in kidney. Excretion of 99m Tc-PAHIDa via urine was rapid and was in its original form as shown by radiochromatography

  8. Preoperative nodal staging of non-small cell lung cancer using 99mTc-sestamibi spect/ct imaging

    Directory of Open Access Journals (Sweden)

    Juliana Muniz Miziara

    2011-01-01

    Full Text Available OBJECTIVES: The proper nodal staging of non-small cell lung cancer is important for choosing the best treatment modality. Although computed tomography remains the first-line imaging test for the primary staging of lung cancer, its limitations for mediastinum nodal staging are well known. The aim of this study is to evaluate the accuracy of hybrid single-photon emission computed tomography and computed tomography using 99mTc-sestamibi in the nodal staging of patients with non-small cell lung cancer and to identify potential candidates for surgical treatment. METHODS: Prospective data were collected for 41 patients from December 2006 to February 2009. The patients underwent chest computed tomography and single-photon emission computed tomography/computed tomography examinations with 99mTc-sestamibi within a 30-day time period before surgery. Single-photon emission computed tomography/computed tomography was considered positive when there was focal uptake of sestamibi in the mediastinum, and computed tomography scan when there was lymph nodes larger than 10 mm in short axis. The results of single-photon emission computed tomography and computed tomography were correlated with pathology findings after surgery. RESULTS: Single-photon emission computed tomography/computed tomography correctly identified six out of 19 cases involving hilar lymph nodes and one out of seven cases involving nodal metastases in the mediastinum. The sensitivity, specificity, positive predictive value, and negative predictive value for 99mTc-sestamibi single-photon emission computed tomography/computed tomography in the hilum assessment were 31.6%, 95.5%, 85.7%, and 61.8%, respectively. The same values for the mediastinum were 14.3%, 97.1%, 50%, and 84.6%, respectively. For the hilar and mediastinal lymph nodes, chest tomography showed sensitivity values of 47.4% and 57.1%, specificity values of 95.5% and 91.2%, positive predictive values of 90% and 57.1% and negative

  9. Preoperative nodal staging of non-small cell lung cancer using 99mTc-sestamibi SPECT/CT imaging

    International Nuclear Information System (INIS)

    Miziara, Juliana Muniz; Rocha, Euclides Timoteo da; Miziara, Jose Elias Abrao; Garcia, Gustavo Fabene; Simoes, Maria Izilda Previato; Lopes, Marco Antonio; Kerr, Ligia Maria; Buchpiguel, Carlos Alberto

    2011-01-01

    Objectives: The proper nodal staging of non-small cell lung cancer is important for choosing the best treatment modality. Although computed tomography remains the first-line imaging test for the primary staging of lung cancer, its limitations for mediastinum nodal staging are well known. The aim of this study is to evaluate the accuracy of hybrid single-photon emission computed tomography and computed tomography using 99m Tc-sestamibi in the nodal staging of patients with non-small cell lung cancer and to identify potential candidates for surgical treatment. Methods: Prospective data were collected for 41 patients from December 2006 to February 2009. The patients underwent chest computed tomography and single-photon emission computed tomography/computed tomography examinations with 99m Tc-sestamibi within a 30-day time period before surgery. Single-photon emission computed tomography/computed tomography was considered positive when there was focal uptake of sestamibi in the mediastinum, and computed tomography scan when there was lymph nodes larger than 10 mm in short axis. The results of single-photon emission computed tomography and computed tomography were correlated with pathology findings after surgery. Results: Single-photon emission computed tomography/computed tomography correctly identified six out of 19 cases involving hilar lymph nodes and one out of seven cases involving nodal metastases in the mediastinum. The sensitivity, specificity, positive predictive value, and negative predictive value for 99m Tc-sestamibi single-photon emission computed tomography/computed tomography in the hilum assessment were 31.6%, 95.5%, 85.7%, and 61.8%, respectively. The same values for the mediastinum were 14.3%, 97.1%, 50%, and 84.6%, respectively. For the hilar and mediastinal lymph nodes, chest tomography showed sensitivity values of 47.4% and 57.1%, specificity values of 95.5% and 91.2%, positive predictive values of 90% and 57.1% and negative predictive values of 67

  10. Initial Evaluation of (99m)Tc(CO)3(ASMA) as a Renal Tracer in Healthy Human Volunteers.

    Science.gov (United States)

    Lipowska, Malgorzata; Klenc, Jeffrey; Folks, Russell D; Taylor, Andrew T

    2014-09-01

    Preclinical studies in rats showed that two of (99m)Tc(CO)3(ASMA) isomers (rac- and L-ASMA) had pharmacokinetic properties equivalent to that of (131)I-OIH, the radiopharmaceutical standard for the measurement of effective renal plasma flow. The aim of this study was to evaluate the pharmacokinetics of (99m)Tc(CO)3(ASMA) isomers in healthy human subjects. Three ASMA ligands (rac-, L- and D-ASMA) were labeled with (99m)Tc(CO)3 using an IsoLink kit (Covidien), and each formed (99m)Tc(CO)3(ASMA) tracer was co-injected with (131)I-OIH into healthy human subjects followed by sequential imaging, plasma clearance measurements and timed urine collection. Plasma protein binding, red cell uptake and percent injected dose in the urine were determined. Urine from each group of volunteers was analyzed for metabolites by HPLC. Image quality was excellent with all three agents. Each (99m)Tc(CO)3(ASMA) preparation was excreted unchanged in the urine. The plasma clearance ratio ((99m)Tc(CO)3(ASMA)/(131)I-OIH) was 81 ± 3 % for D-ASMA compared to only 20 ± 4 % for L-ASMA and 37 ± 7 % for rac-ASMA; the 81 % clearance ratio for D-ASMA isomer is still ∼ 30 % higher than the (99m)Tc-MAG3/(131)I-OIH clearance ratio (∼50-60 %). Red cell uptake was similar for all three tracers (6-9 %), and all tracers had a relatively rapid renal excretion; at 3 h, the (99m)Tc(CO)3(ASMA)/(131)I-OIH urine ratio was 100 ± 3 % for D-ASMA, 80 ± 2 % for L-ASMA and 88 ± 1 % for rac-ASMA. The renal excretion characteristics of (99m)Tc(CO)3(D-ASMA) in humans are superior to those of the other two (99m)Tc(CO)3(ASMA) isomers studied, but are still inferior to (131)I-OIH, even though there was no difference in the clearance of two of (99m)Tc(CO)3(ASMA) isomers and (131)I-OIH in rats. The work described here demonstrates the sensitivity in in vivo biological behavior of (99m)Tc(CO)3(ASMA) isomers to their subtle structural differences.

  11. Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals.

    Science.gov (United States)

    Uccelli, Licia; Boschi, Alessandra; Martini, Petra; Cittanti, Corrado; Bertelli, Stefania; Bortolotti, Doretta; Govoni, Elena; Lodi, Luca; Romani, Simona; Zaccaria, Samanta; Zappaterra, Elisa; Farina, Donatella; Rizzo, Carlotta; Giganti, Melchiore; Bartolomei, Mirco

    2018-03-15

    The influence of effective room temperature on the radiochemical purity of 99m Tc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the 99m Tc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the work area, the presence of instruments for heating, the continuous activation of air filtration, in addition to the fact that the environment of the isolator used for the 99m Tc-radiopharmaceuticals preparation and storage is completely isolated and not conditioned. A total of 244 99m Tc-radiopharmaceutical preparations (seven different types) have been tested and the radiochemical purity was checked at the end of preparation and until the expiry time. Moreover, we found that the mean temperature into the isolator was significantly higher than 25 °C, the temperature, in general, required for the preparation and storage of 99m Tc-radiopharmaceuticals. Results confirmed the radiochemical stability of radiopharmaceutical products. However, as required in the field of quality assurance, the impact that different conditions than those required by the manufacturer on the radiopharmaceuticals quality have to be verified before human administration.

  12. Use of hypoxia imaging agent 99mTc-HL91 in rat cerebral ischemia models

    International Nuclear Information System (INIS)

    Zhou Ying; Qu Wanying; Li Meng; Chen Fang; Yao Zhiming; Zhu Ming; Zhu Lin

    1999-01-01

    Objective: To explore the possibility of diagnosis for cerebrovascular disease by a novel synthetic hypoxia agent 99m Tc-HL91 used in rat cerebral ischemia models. Methods: Pharmacological experiments of 99m Tc-HL91 were carried out including common properties, radiochemical purity, stability in vitro, anomalous toxicity test and biodistribution in mice. Fifteen cerebral ischemic rat models were established and received 99m Tc-HL91 scintigraphy. Results: 1) HL91 kits were labelled with 99m Tc easily and showed high radiochemical purity and stability. 2) Rapid clearance in blood, heart and lungs and high activity in liver, kidneys and intestines were observed. Relatively low uptake in brain was identified. 3) The radioactivity in ischemic brain tissue increased significantly at 4h postinjection in both rat images and isolated brain images. 4) The radioactivity ratios of lesion to normal brain tissue by drawing ROIs in isolated brain planar images were 0.98 +- 0.06, 0.99 +- 0.05, 1.29 +- 0.03, 1.56 +- 0.14 and 1.66 +- 0.06 at 1,2,4,8 and 12 h postinjection, respectively. There were significant differences among all groups except for 1 h and 2 h, 8 h and 12 h postinjection (P 99m Tc-HL91 in the hypoxic, ischemic brain tissue have been proved. It is appropriate to perform imaging at 4 h postinjection

  13. Evaluation of time dependency of the acetazolamide effect on cerebral hemodynamics as measured by {sup 99m}Tc-ECD single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Takaki, Akihiro; Urata, Joji; Okada, Kazuhiro; Takaki, Rie [Saiseikai Kumamoto Hospital (Japan). Diagnostic Imaging Center; Mizuta, Yoshihiko; Murakami, Masaji; Yonehara, Toshiroh; Hirano, Teruyuki; Fujioka, Shodo

    2001-01-01

    Kuwabara et al. have examined the cerebral artery dilation with acetazolamide (ACZ) challenge test using PET. And, they reported that ACZ reaction came out time dependently. We have developed a unique SPECT's method using Technetium-99m ethyl cysteinate dimer ({sup 99m}Tc-ECD) to verify the results obtained by Kuwabara et al. One thousand MBq of {sup 99m}Tc-ECD was exactly divided into three syringes. Each of which was intravenous infused (IV) at rest, 7.5, and 20 minutes after ACZ administration. Data collection was started using dynamic SPECT immediately after {sup 99m}Tc-ECD IV at rest. Using necessary data only, SPECT images representing each of the three {sup 99m}Tc-ECD IV was reconstructed. SPECT counts were obtained by the ROI method from each images to calculate relative CBF from rest to 7.5 and 20 minutes after ACZ administration. The 18 hemispheres of nine patients in the negative control group in whom ACZ was not loaded, CBF was stable during the three evaluation. The measurement error our method was estimated as small. The 18 hemispheres of nine patients in the positive control group who has normal vasodilatory reserve, CBF was increased by 26.2{+-}8.1% at 7.5 minutes and 29.3{+-}13.1% at 20 minutes after ACZ administration. Seven patients with and chronic stage unilateral internal carotid artery severe stenosis and/or occlusion were evaluated as the test group. Case of unaffected side, CBF was increased by 17.6{+-}6.9% at 7.5 minutes and 24.8{+-}11.3% 20 minutes after ACZ administration. And, increase rate of CBF in the affected side was 2.8{+-}1.6% at 7.5 minutes and 17.3{+-}5.0% at 20 minutes after ACZ administration. In the affected side, timing of the maximum CBF increase caused by ACZ was remarkably delayed. Our method based on {sup 99m}Tc-ECD SPECT also revealed delayed cerebral artery dilation in the affected side. It was suggested that ACZ reaction came out time dependently, as reported by Kuwabara et al. (author)

  14. Study of Eustachian tube drainage function with radioisotope (99m-Tc)

    International Nuclear Information System (INIS)

    Marone, S.A.M.; Miniti, A.

    1985-01-01

    The knowledge of the physiological condition of the Eustachian tube is of major significance to the understanding of the middle ear pathology as well as for the treatment of each case. This paper studies the drainage function of the Eustachian tube. The choice of the Technetium (99m-Tc) as tracer was based on its physical qualities - tracer perfectly adaptable to the detection system, pure gamma emitter, low energy and 6 hours half-life. The use of Tc-99m turns out to be a very accurate method for testing the drainage function. It is an entirely physiological method, and it produces no side effect reactions. (Auth.)

  15. The labeling of white blood cells with 99mTc and 111In complexes

    International Nuclear Information System (INIS)

    Hadizad, T.; Najafi, R.

    1993-01-01

    Leukocytes have been labelled with a variety of gamma emitters and labelled (mixed) leukocytes are used clinically to detect and localize sites of abscess in the abdominal area and inflammatory processes surrounding grafts, ulcerative colitis and study of leukocyte kinetics. In this project we used 99m Tc-Sn-Pyp, 99m Tc-Hexamethyl propenylamine oxine, 111 In-Tropolone and 111 In-Oxine Sulfate for the labelling of leukocytes. All the in vitro and in vivo tests have been done to get an optimum condition for injection

  16. Qualification of a production and packaging hot cell for sodium pertechnetate Tc 99m

    International Nuclear Information System (INIS)

    Cavero, Luis; Robles, Anita; Miranda, Jesus; Martinez, Ramos; Paragulla, Wilson; Moore, Mariel; Herrera, Jorge; Ocana, Elias; Portilla, Arturo; Otero, Manuel; Novoa, Carlos; Koga, Roberto

    2014-01-01

    It was designed and implemented a protocol for a hot cell of production and packaging of sodium pertechnetate Tc 99m, in a two-step process: installation qualification (IQ) and operation qualification (OQ). In the IQ design specifications and user requirements and associated equipment and materials by traceable documentation was verified. In the OQ scheduled for operation and control sequences it was verified plus operational tests recommended by the World Health Organization (WHO) and ISO 14644-1 and 3 were performed to clean areas. The results showed that the hot cell complies with the classification for Grades C and A for the preparation and packaging of Tc 99m. (authors).

  17. Cyclohexanone solvent extraction of 99TcO4 from alkaline nuclear waste solutions

    International Nuclear Information System (INIS)

    Schulz, W.W.

    1980-01-01

    Although the 99 Tc cyclohexanone solvent extraction process is still in the bench-scale development stage, the process appears well suited for engineering-scale removal of 99 Tc from alkaline Hanford waste solutions. The most pressing process development need is to resolve the phase disengaging problems encountered during water stripping operations. Stripping tests in pulse columns and/or centrifugal contactors are particularly needed to determine the magnitude of the phase disengaging problem in engineering-scale equipment and to find suitable remedies. 5 figures, 7 tables

  18. Preclinical pharmacological study of 99mTcN(NOET)2 and comparison with 201Tl in redistribution of ischemia myocardium

    International Nuclear Information System (INIS)

    Wang, J.C.; Zhang, J.B.; Wang, Q.; Mi, H.Z.; Wang, X.B.

    2002-01-01

    Aim: To study the biological properties of the myocardial imaging agent 99m TcN(NOET) 2 and compare with 201 Tl in redistribution of ischemia myocardium. Materials and Methods: To prepared the 99m TcN(NOET) 2 complex, the intermediate [ 99m TcN] 2+ and ligand NOET were synthesized. In the presence of reducer and the doner of N, the [ 99m Tc=N] 2+ could be synthesized at 100, then NOET was added, 99m TcN(NOET) 2 was formed at room temperature. 201 Tl was provided by the Department of Isotope, China Institute of Atomic Energy. Five dogs were from the Fu Wai experimental animal feeding center, two of them were made into ischemia myocardium models by ligating some coronary artery branches were demonstrated by X-ray coronary angiography, the extent of stenosis of those blood vessels was over 90%. Dynamic imaging of rest was performed respectively in three normal dogs after injecting a dose of 555MBq (15mCi) of 99m TcN(NOET) 2 complex up to two hours. The whole body imaging planar and tomography imaging was carried out respectively at fixed time intervals during two hours in order to obtain the time-activity curves of heart, lung and liver, in vivo biodistribution and quality analysis of myocardial images. Moreover, intravenous blood samples were collected at different times to gain the kinetics of blood clearance. Stress and redistribution imaging underwent in two dogs with ischemia myocardium. Dipyridamol was given intravenously at a dose of 0.6mg/Kg in 4 mins. Stress :9 9m TcN(NOET) 2 myocardial SPECT imaging was performed at 30, 70 and 110 min after injection of 99m TcN(NOET) 2 complex, stress 201 Tl myocardial SPECT imaging was carried out 10 min and redistribution imaging 4 hr after injection of 55.5MBq (1.5mCi) 201 Tl chloride. The tests of 99m TcN(NOET) 2 and 201 Tl were performed respectively in the same dog within 10 days, in order to obtain a comparison between two myocardial redistribution imaging. Results: Radiochemical purity of 99m TcN(NOET) 2 was 98.41%

  19. Targeting osteomyelitis with complete [99mTc]besilesomab and fragmented [99mTc]sulesomab antibodies: kinetic evaluations

    International Nuclear Information System (INIS)

    GRATZ, Stefan; KEMKE, Bendix; KEIZE, Patrik; KAMPEN, Wim U.; LUSTER, Markus; HÖFFKEN, Helmut

    2016-01-01

    The aim of this retrospective study was to compare the targeting of “pure” osteomyelitis (i.e., without surrounding soft tissue infection) by directly 99mTc-labelled complete immunoglobulin G (IgG) monoclonal antibody (MAb) ([99mTc]besilesomab) and by directly 99mTc-labelled fragment antigen-binding (FAb) MAb ([99mTc]sulesomab) in relation to their kinetic fate. A total of 73 patients with “pure” osteomyelitis were examined with [99mTc]besilesomab, (Scintimun®, IBA/CIS bio international, Saclay, France; N.=38) and [99mTc]sulesomab (LeukoScan®, Immunomedics Inc., Morris Plains, NJ, USA; N.=35). Kinetic data were deduced from whole-body and single-photon emission computed tomographic scans, performed 10 minutes to 24 hour p.i. (region-of-interest technique [ROI]). In targeting “pure” osteomyelitis, sensitivities at 1-4 hours were found to be higher for [99mTc]sulesomab (44% and 80% for [99mTc]besilesomab and [99mTc]sulesomab, respectively) but at significantly lower target/background (T/B) ratios than with [99mTc]besilesomab (1.8±0.3 versus 1.4±0.5 for [99mTc]besilesomab and [99mTc]sulesomab respectively; P<0.01). With [99mTc]besilesomab, there was a continuous osteomyelitis uptake over 24 hours, whereas with [99mTc]sulesomab, the maximal uptake occurred mostly within 1-4 hours, with subsequent clearance being slower for antigen-bound activity than for nonspecific background. Hence, diagnosis was possible mostly after 4h with [99mTc]sulesomab but often not before 24 hours with [99mTc]besilesomab, the later increasing significantly (P<0.01) in sensitivity (87% and 84% for [99mTc]besilesomab and [99mTc]sulesomab, respectively). These results show that the higher sensitivity of [99mTc]sulesomab in osteomyelitis targeting at earlier p.i. times does not rely on an increased antibody uptake but on a more rapid clearance of nonspecific background activity due to faster metabolism and excretion. Intact [99mTc]besilesomab show a slow, continuous uptake

  20. New superconductors from granular to high T$_{c}$

    CERN Document Server

    Deutscher, Guy

    2018-01-01

    How new are the high Tc superconductors, as compared to the conventional low Tc ones? In what sense are these oxides different from regular metals in their normal state? How different is the mechanism for high Tc superconductivity from the well-known electron-phonon interaction that explains so well superconductivity in metals and alloys? What are the implications of the new features of the high Tc oxides for their practical applications? This interesting book aims to provide some answers to those questions, drawing particularly on similarities between the high Tc oxides and granular superconductors, which also present a short coherence length, a small superfluid density and an inhomogeneous structure.

  1. New superconductors from granular to high T$_{c}$

    CERN Document Server

    Deutscher, Guy

    2006-01-01

    How new are the high Tc superconductors, as compared to the conventional low Tc ones? In what sense are these oxides different from regular metals in their normal state? How different is the mechanism for high Tc superconductivity from the well-known electron-phonon interaction that explains so well superconductivity in metals and alloys? What are the implications of the new features of the high Tc oxides for their practical applications? This book aims to give some answers to those questions, drawing particularly on similarities between the high Tc oxides and granular superconductors, which also present a maximum of their critical temperature near the metal-insulator transition.

  2. Direct provision versus facility collection of HIV self-tests among female sex workers in Uganda: A cluster-randomized controlled health systems trial.

    Directory of Open Access Journals (Sweden)

    Katrina Ortblad

    2017-11-01

    Full Text Available HIV self-testing allows HIV testing at any place and time and without health workers. HIV self-testing may thus be particularly useful for female sex workers (FSWs, who should test frequently but face stigma and financial and time barriers when accessing healthcare facilities.We conducted a cluster-randomized controlled health systems trial among FSWs in Kampala, Uganda, to measure the effect of 2 HIV self-testing delivery models on HIV testing and linkage to care outcomes. FSW peer educator groups (1 peer educator and 8 participants were randomized to either (1 direct provision of HIV self-tests, (2 provision of coupons for free collection of HIV self-tests in a healthcare facility, or (3 standard of care HIV testing. We randomized 960 participants in 120 peer educator groups from October 18, 2016, to November 16, 2016. Participants' median age was 28 years (IQR 24-32. Our prespecified primary outcomes were self-report of any HIV testing at 1 month and at 4 months; our prespecified secondary outcomes were self-report of HIV self-test use, seeking HIV-related medical care and ART initiation. In addition, we analyzed 2 secondary outcomes that were not prespecified: self-report of repeat HIV testing-to understand the intervention effects on frequent testing-and self-reported facility-based testing-to quantify substitution effects. Participants in the direct provision arm were significantly more likely to have tested for HIV than those in the standard of care arm, both at 1 month (risk ratio [RR] 1.33, 95% CI 1.17-1.51, p < 0.001 and at 4 months (RR 1.14, 95% CI 1.07-1.22, p < 0.001. Participants in the direct provision arm were also significantly more likely to have tested for HIV than those in the facility collection arm, both at 1 month (RR 1.18, 95% CI 1.07-1.31, p = 0.001 and at 4 months (RR 1.03, 95% CI 1.01-1.05, p = 0.02. At 1 month, fewer participants in the intervention arms had sought medical care for HIV than in the standard of care arm

  3. Status and future application of pilot lead-bismuth target circuit TC-1 for ADS

    Energy Technology Data Exchange (ETDEWEB)

    Ignatiev, S.; Leonchuk, M.; Orlov, Y.; Pankratov, D.; Reshetnikova, O.; Suvorov, G.; Zabudko, A. [Institute for Physics and Power Engineering, Obninsk (Russian Federation); Stepanov, V.; Klimov, N. [Experimental and Design Organization, Gidropress, Podolsk (Russian Federation); Hechanova, A.; Ma, J. [Nevada Univ., Las Vegas, NV (United States); Li, N. [Los Alamos National Lab., NM (United States); Gudowski, W. [International Science and Technology Center, Moscow (Russian Federation)

    2007-07-01

    A complicated evolution, status and future application of the pilot molten lead-bismuth target circuit of 1 MW proton beam power (TC-1) as an important part of a target-blanket accelerator driven system (ADS), that has been developed, created and twice tested under the auspice of the International Science and Technology Center (ISTC), is analyzed. The target complex TC-1 is a circulation lead-bismuth loop whose beam window is made of ferritic steel EP-823 (this steel was used in the past as material of fuel rods cladding in reactors cooled with lead-bismuth). At present TC-1 is operating at coolant temperature up to 300 C degrees and will be used to study different issues linked to the use of lead-bismuth: -) interaction with air, water and hydrogen, -) different regimes of flow, -) corrosion, -) filtering, or -) slag formation.

  4. Role of 99mTc-mebrofenin in evaluation of neonatal cholestasis syndrome

    International Nuclear Information System (INIS)

    Maini, Atul; Khanduri, Arun; Gambhir, S.; Yacha, S.K.; Das, B.K.

    1997-01-01

    We prospectively evaluated 40 patients with neonatal cholestasis syndrome (NCS) over a period of 2.5 years. Main aim was to evaluate the efficacy of hepatobiliary scintigraphy using 99m Tc-mebrofenin, without phenobarbital induction, in differentiating Extrahepatic Biliary Atresia (EHBA) from Neonatal Hepatitis (NH). All infants were clinically examined. Liver function tests, ultrasonography and liver biopsy were carried out in each case. EHBA was diagnosed either by per-operative cholangiography or scintigraphy and liver biopsy. NH was diagnosed by liver histology and ultrasonography or by scintigraphy or by per operative cholangiography. Our sensitivity (100%) and specificity (80%) were found to be similar to results of previous studies using other 99m Tc-IDA agents with phenobarbital induction. Therefore, with 99m Tc-mebrofenin phenobarbital induction may not be needed in differentiating EHBA from NH, thus decreasing the time of diagnostic evaluation. (author)

  5. Bioaccumulation and chemical modification of Tc by soil bacteria

    International Nuclear Information System (INIS)

    Henrot, J.

    1989-01-01

    Bioaccumulation and chemical modification of pertechnetate (TcO 4 -) by aerobically and anaerobically grown soil bacteria and by pure cultures of sulfate-reducing bacteria (Desulfovibrio sp.) were studied to gain insight on the possible mechanisms by which bacteria can affect the solubility of Tc in soil. Aerobically grown bacteria had no apparent effect on TcO 4 -; they did not accumulate Tc nor modify its chemical form. Anaerobically grown bacteria exhibited high bioaccumulation and reduced TcO 4 -, enabling its association with organics of the growth medium. Reduction was a metabolic process and not merely the result of reducing conditions in the growth medium. Association of Tc with bacterial polysaccharides was observed only in cultures of anaerobic bacteria. Sulfate-reducing bacteria efficiently removed Tc from solution and promoted its association with organics. Up to 70% of the total Tc in the growth medium was bioaccumulated and/or precipitated. The remaining Tc in soluble form was entirely associated with organics. Pertechnetate was not reduced by the same mechanism as dissimilatory sulfate reduction, but rather by some reducing agent released in the growth medium. A calculation of the amount of Tc that could be associated with the bacterial biomass present in soil demonstrates that high concentration ratios in cultures do not necessarily imply that bioaccumulation is an important mechanism for long-term retention of Tc in soil

  6. 99mTc-stannous colloid white cell scintigraphy in childhood inflammatory bowel disease.

    Science.gov (United States)

    Peacock, Kenneth; Porn, Ute; Howman-Giles, Robert; O'Loughlin, Edward; Uren, Roger; Gaskin, Kevin; Dorney, Stuart; Kamath, Ramanand

    2004-02-01

    99mTc-Labeled white cell scintigraphy (WCS) has been used for the investigation of inflammatory bowel disease (IBD) in adults, but data on children are limited. The most common agent used is (99m) Tc-hexamethylpropyleneamine oxime (HMPAO); however, this agent has limitations. In a retrospective study, we assessed the use of (99m)Tc-stannous colloid WCS for the initial evaluation of children with suspected IBD. Diagnostic, endoscopic, and contrast radiography results were retrospectively collected from the medical records. Two experienced nuclear physicians unaware of the patient data interpreted the WCS results, with agreement reached by consensus. Statistical analysis was performed on the ability of WCS to detect active disease and localize it topographically and on a comparison of diagnostic methods, using a combination of clinical features and endoscopy as the reference standard. Between 1996 and 1999, 64 patients (35 male and 29 female; mean age, 12.5 y; age range, 2-19 y) had WCS performed, with IBD subsequently diagnosed in 34 patients. (99m)Tc-Stannous colloid WCS had an 88% sensitivity, 90% specificity, and 8.8 likelihood ratio for initial investigation of IBD. Agreement was poor for topographic localization of disease. Small-bowel series had a 75% sensitivity, 50% specificity, and 1.5 likelihood ratio for detecting endoscopic disease of the terminal ileum and proximal colon. Our results confirm that WCS is a useful imaging technique for the initial evaluation of patients with suspected IBD. (99m)Tc-Stannous colloid had results at least comparable to those of other WCS agents, and in children, (99m)Tc-stannous colloid WCS should be preferred in view of lower cost, shorter preparation time, and the smaller blood volumes required.

  7. Diagnostic test accuracy study of 18F-sodium fluoride PET/CT, 99mTc-labelled diphosphonate SPECT/CT, and planar bone scintigraphy for diagnosis of bone metastases in newly diagnosed, high-risk prostate cancer

    DEFF Research Database (Denmark)

    Fonager, Randi F; Zacho, Helle D; Langkilde, Niels C

    2017-01-01

    The aim of this study was to prospectively compare planar, bone scan (BS) versus SPECT/CT and NaF PET/CT in detecting bone metastases in prostate cancer. Thirty-seven consecutive, newly diagnosed, prostate cancer patients with prostate specific antigen (PSA) levels ≥ 50 ng/mL and who were...... considered eligible for androgen-deprivation therapy (ADT) were included in this study. BS, SPECT/CT, and NaF PET/CT, were performed prior to treatment and were repeated after six months of ADT. Baseline images from each index test were independently read by two experienced readers. The reference standard......%, and 96%, respectively, and the negative predictive values were 60%, 77% and 75%, respectively. No statistically significant difference among the three imaging modalities was observed. All three imaging modalities showed high sensitivity and specificity. NaF PET/CT and SPECT/CT showed numerically improved...

  8. 99mTc-interleukin-2 scintigraphy for the in vivo imaging of vulnerable atherosclerotic plaques

    International Nuclear Information System (INIS)

    Annovazzi, Alessio; D'Alessandria, Calogero; Scopinaro, Francesco; Bonanno, Elena; Spagnoli, Luigi G.; Arca, Marcello; Marcoccia, Antonella; Violi, Francesco; Toma, Giorgio De; Signore, Alberto

    2006-01-01

    Several histopathological studies have demonstrated that vulnerable plaques are enriched in inflammatory cells. The aims of this study were: (1a) to test the ability of 99m Tc-labelled interleukin-2 ( 99m Tc-IL2) to bind to IL2R-positive (IL2R+) cells in carotid plaques and (1b) to correlate the plaque uptake of 99m Tc-IL2, measured in vivo, with the number of IL2R+ cells within the plaque, measured ex vivo by histology (transversal study, TS), and (2) to evaluate changes in 99m Tc-IL2 uptake in plaques, before and after treatment with a statin or a hypocholesterolaemic diet (longitudinal study, LS). Ultrasound scan was performed for plaque characterisation and localisation. Fourteen patients (16 plaques) eligible for endoarterectomy were recruited for the TS and underwent 99m Tc-IL2 scintigraphy before surgery. Nine patients (13 plaques) were recruited for the LS; these patients received atorvastatin or a standard hypocholesterolaemic diet and 99m Tc-IL2 scintigraphy was performed before and after 3 months of treatment. The degree of 99m Tc-IL2 uptake was expressed as the plaque/background (T/B) ratio. In patients from TS, T/B ratios correlated with the percentage of IL2R+ cells at histology (r=0.707; p=0.002) and the number of IL2R+ cells at flow cytometry (r=0.711; p=0.006). No correlations were observed between ultrasound scores and either scintigraphic or histological findings. In patients from the LS, the mean 99m Tc-IL2 uptake decreased in statin-treated patients (1.75±0.50 vs 2.16±0.44; p=0.012), while it was unchanged in the patients on the hypocholesterolaemic diet (2.33±0.45 vs 2.34±0.5). 99m Tc-IL2 accumulates in vulnerable carotid plaques; this accumulation is correlated with the amount of IL2R+ cells and is influenced by lipid-lowering treatment with a statin. (orig.)

  9. Evaluation of the absorbed dose to the kidneys due to Tc99m (DTPA) / Tc99m (Mag3) and Tc99m (Dmsa)

    International Nuclear Information System (INIS)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P.; Idrogo C, J.; Marquez P, F.

    2015-10-01

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc 99m (DTPA) / Tc 99m (Mag3) or Tc 99m (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc 99m (DTPA) / Tc 99m (Mag3), are given by 0.00466 mGy.MBq -1 / 0.00339 mGy.MBq -1 . Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc 99m (DTPA) / Tc 99m (Mag3). The absorbed dose to the kidneys due to Tc 99m (Dmsa) is 0.17881 mGy.MBq -1 . Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc 99m (Dmsa). (Author)

  10. On the organ distribution of a selection of 99mTc-tagged tetracyclines

    International Nuclear Information System (INIS)

    Weinhold, S.E.M.

    1983-01-01

    During this study the time course of organ concentrations of 99mTc-tagged tetracycline and of 99mTc-rolitetracycline that had been labeled according to two different methods was investigated with reference to that of two standard preparations, 99mTcO 4 and 3 H-labeled tetracycline, which differ from the test substances in their chemical structures (lipohilia - hydrophilia). As the substances to be investigated here are chemically related, they showed mostly consistent organ concentrations and great vivo stability. The concentrations measured in the organs examined (particularly the lungs) followed the same pattern as the concentrations in the blood and were thus regarded as being primarily the result of convection processes, whereas the concentrations seen in some other organs (especially the kidneys and, to a lesser extent, the liver) rather appeared to be determined by invasion and evasion processes; this held true for 99mTc-labeled tetracyclines as well as for pertechnetate. None of the five substances tested during this study appeared to be able to pass the blood-brain barrier. As regards solubility in water, the 99mTc-labeled tetracyclines occupy an intermediate position between pertechnetate (extremely water-soluble) and 3 H-labeled tetracyclines (extremely lipophil), which can be seen from the moderately high blood concentrations of these preparations. In view of the high organ concentrations that are observed particularly in the kidneys following administration of 99mTc-labeled tetracycline and rolitetracycline, the use of these substances for renal scintiscanning appears worth considering, as only approx. one tenth of the dose of pertechnetate would be required for this purpose. (TRV) [de

  11. The Origin of Tc Enhancement in Heterostructure Cuprate Superconductors

    Directory of Open Access Journals (Sweden)

    Doron L. Bergman

    2011-10-01

    Full Text Available Recent experiments on heterostructures composed of two or more films of cuprate superconductors of different oxygen doping levels have shown a remarkable Tc enhancement (up to 50% relative to single compound films. We provide a simple explanation of the enhancement which arises naturally from a collection of experimental works. We show that the enhancement could be caused by a structural change in the lattice, namely an increase in the distance of the apical oxygen from the copper-oxygen plane. This increase modifies the effective off-site interaction in the plane which in turn enhances the d-wave superconductivity order parameter. To illustrate this point we study the extended Hubbard model using the fluctuation exchange approximation.

  12. Determination of the Tc distribution for 1000 Transition Edge Sensors

    International Nuclear Information System (INIS)

    Brink, P.L.; Saab, T.; Miller, A.J.; Cabrera, B.; Castle, J.P.; Chang, C.; Young, B.A.; Akerib, D.S.; Discroll, D.; Kamat, S.; Perera, T.A.; Schnee, R.W.; Wang, G.; Emes, J.H.; Gaitskell, R.J.; Mandic, V.; Meunier, P.; Rau, W.; Sadoulet, B.; Seitz, D.N.

    2002-01-01

    The ZIP detectors deployed in the CDMS II experiment utilize phonon sensors comprising W Transition Edge Sensors (TESs). In order to ensure uniform collection of the athermal phonon signal the TESs are dispersed uniformly on one side of a 1 cm thick, 3 inch diameter, disk. Each quadrant contains 1036 TESs connected in parallel to one series-array SQUID amplifier. The initial superconducting transition temperatures of these TESs tend to be too high for our requirements, and substantial gradients make the operation of the detectors difficult. Hence our implementation of Fe-56 ion implantation, as reported at the previous LTD meeting, to reduce in a controlled manner the transition temperature. However, the successful implementation of this ion-implantation scheme requires accurate knowledge of the initial transition temperature of each TES in a given quadrant. We report on our approaches and techniques employed to address the issue of determining the initial Tc distribution

  13. Accumulation of Tc-99m-MIBI and Tc-99m-tetrofosmin in tumor cells. Uptake and washout studies

    International Nuclear Information System (INIS)

    Rodrigues, M.; Aghajanian, A.A.; Sinzinger, H.; Kalinowska, W.; Zielinski, C.

    2002-01-01

    Aim: To investigate in-vitro the uptake and washout of Tc-99m-MIBI and Tc-99m-tetrofosmin in human breast adenocarcinoma and soft tissue sarcoma cell lines. Methods: The uptake of Tc-99m-MIBI and Tc-99m-tetrofosmin (at 37 0 C, 10, 30 and 60 minutes after incubation with 7.4x10E5 Bq each tracer) was investigated in breast adenocarcinoma MCF-7 and SK-BR-3 cells, synovial sarcoma SW 982 cells and chondrosarcoma SW 1353 cells (concentration of 1x10E6 cells/ml incubation medium). Tracer uptake in cells incubated with ouabain (Na/K-ATPase pump inhibitor; 100 μM and 1mM; 15 and 30 minutes), nigericin (increases mitochondrial potential and disrupts cell membrane potential; 5 and 50 μg/ml; 15 minutes) and carbonyl cyanide m-chlorophenylhydrazone (CCCP) (depolarizes mitochondrial membrane; 10 and 100 μM; 30 minutes) was compared to that in cells without incubation with chemical agents (control cells). The washout (at 37 0 C, 10-60 minutes, 30 and 60 minutes after tracer incubation) of Tc-99m-MIBI and Tc-99m-tetrofosmin was studied in MCF-7 cells, SK-BR-3 cells , SW 1353 cells and fibrosarcoma SW 684 cells. Results: Cellular tracer uptake decreased with ouabain (decrease of Tc-99m-tetrofosmin > Tc-99m-MIBI in SK-BR-3 cells and SW 982 cells) and increased with nigericin (increase of Tc-99m-MIBI > Tc-99m-tetrofosmin in all cells) as compared to the uptake in control cells. With CCCP, decrease of Tc-99m-MIBI uptake in cells preincubated with nigericin was higher than that in cells under basal conditions, whereas a similar decrease of Tc-99m-tetrofosmin uptake in these two group of cells was found. Washout of Tc-99m-MIBI from all cells was lower than that of Tc-99m-tetrofosmin. No significant difference in cell-associated activity of both tracers was found between washout after 30 minutes and that after 60 minutes of incubation, in all cells. Washout of Tc-99m-MIBI from SK-BR-3 cells Tc-99m-tetrofosmin) and Na/K-ATPase pump (Tc-99m-tetrofosmin > Tc-99m-MIBI). Tc-99m-MIBI and

  14. Use of 99mTc-HMPAO-leucocyte scintigraphy coupled to 99mTc-colloid scintigraphy in diagnosing the osteo-articular sepsis

    International Nuclear Information System (INIS)

    Darlas, Y.; Pegoix, M.; Filmont, J.E.; Leclercq, S.; Rosas, M.H.; Agostini, D.; Aubriot, J.H.; Bouvard, G.

    1997-01-01

    The object of this study was the scintigraphic diagnosis of osseous sepsis based on the absence of congruence between leucocytic and colloidal fixations and the evaluation of the effect of coupling between the scintigraphies (sc) with leucocytes (A) and colloids (B) on the diagnosis feasibility index of this technique. Seventy four patients, 97 sc were divided into two groups according to the scintigraphic technique [(A) only]: 35 sc; [(A) and (B)]: 62 sc. [Prosthesis: 48 patients, 68 sc. Osteitis: 26 patients, 29 sc]. The scintigraphies were performed as follows: (A) autologous leucocytes labelled by 250 - 300 MBq of 99m Tc-HMPAO, with planar incidences (15 min), 3 - 4 hours after injection and (B) Labelled nano-colloids labelled by 180 - 200 MBq of 99m Tc, the same incidences, 30 min after injection. The delay between (A) and (B): 48 hours. The final diagnosis of sepsis: bacteriological and histologic criteria after biopsies and/or clinical, biological and radiological evolution. The comparison between the two groups is given in a table in terms of prevalence, sensitivity and specificity, using the χ2 and Fisher tests. In conclusion, the scintigraphy by 99m Tc-HMPAO-leucocyte is a sensitive method (Se ∼ 90%) for the diagnosis of osseous sepsis and coupled to the scintigraphy by 99m Tc-colloids allow obtaining a high specificity (Sp ≥ 90%) by reducing the number of falsely positive diagnoses

  15. Adsorption behavior of 99Tc in Ca-bentonite

    International Nuclear Information System (INIS)

    Liu Dejun; Fan Xianhua; Zhang Yingjie; Yao Jun; Zhou Duo; Wang Yong

    2004-01-01

    The adsorption behaviors of 99 Tc in bentonite were studied with batch methods under aerobic and anoxic conditions. The adsorption ratios is about 1.47 mL/g under aerobic conditions. The adsorption ratio of 99 Tc in bentonite is not affected by pH in the range of 5-12 and the CO 3 2- , Fe 3+ concentrations in the range of 10 -8 -10 -2 mol/L in the solution. The adsorption ratio of Tc in bentonite increases with the increase of the mass percent of Fe 2 O 3 and Fe 3 O 4 and the Fe 2+ concentration in the range of 10 -8 -10 -2 mol/L. Tc exists ainly in the form of Tc(VII) after the adsorption equilibriums. The adsorption ratio of Tc in bentonite increase with the increase of the mass percent of Fe and Tc exists mainly in the form of Tc(VII) after the adsorption equilibriums. The adsorption ratio of Tc in bentonite is about 84.84 mL/g under anoxic conditions. The adsorption ratios of 99 Tc in bentonite decreases with the increase of pH in the range of 5-12 and the CO 3 2- concentration in the range of 10 -8 -10 -2 mol/L in the solution. The adsorption ratio of Tc in bentonite increases with the increase of the Fe 3+ , Fe 2+ concentration in the range of 10 -8 -10 -2 mol/L and the mass percent of Fe, Fe 2 O 3 and Fe 3 O 4 . Tc exists mainly in the form of Tc(IV) after the adsorption equilibriums. The adsorption isotherms of TcO 4 - in bentonite are all in fairly agree with the Freundlich's equation under aerobic and anoxic conditions. (authors)

  16. Asteroid 2008 TC3 Breakup and Meteorite Fractions

    Science.gov (United States)

    Goodrich, C.; Jenniskens, P.; Shaddad, M. H.; Zolensky, M. E.; Fioretti, A. M.

    2017-01-01

    The recovery of meteorites from the impact of asteroid 2008 TC3 in the Nubian Desert of Sudan on October 7, 2008, marked the first time meteorites were collected from an asteroid observed in space by astronomical techniques before impacting. Search teams from the University of Khartoum traced the location of the strewn field and collected about 660 meteorites in four expeditions to the fall region, all of which have known fall coordinates. Upon further study, the Almahata Sitta meteorites proved to be a mixed bag of mostly ureilites (course grained, fine grained, and sulfide-metal assemblages), enstatite chondrites (EL3-6, EH3, EH5, breccias) and ordinary chondrites (H5-6, L4-5). One bencubbinite-like carbonaceous chondrite was identified, as well as one unique Rumuruti-like chondrite and an Enstatite achondrite. New analysis: The analysed meteorites so far suggest a high 30-40 percent fraction of non-ureilites among the recovered samples, but that high fraction does not appear to be in agreement with the meteorites in the University of Khartoum (UoK) collection. Ureilites dominate the meteorites that were recovered by the Sudanese teams. To better understand the fraction of recovered materials that fell to Earth, a program has been initiated to type the meteorites in the UoK collection in defined search areas. At this meeting, we will present some preliminary results from that investigation.

  17. Rationale and design of REACT: a randomised controlled trial assessing the effectiveness of home-collection to increase chlamydia retesting and detect repeat positive tests.

    Science.gov (United States)

    Smith, Kirsty S; Hocking, Jane S; Chen, Marcus; Fairley, Christopher K; McNulty, Anna; Read, Phillip; Bradshaw, Catriona S; Tabrizi, Sepehr N; Wand, Handan; Saville, Marion; Rawlinson, William; Garland, Suzanne M; Donovan, Basil; Kaldor, John M; Guy, Rebecca

    2014-04-24

    Repeat infection with Chlamydia trachomatis is common and increases the risk of sequelae in women and HIV seroconversion in men who have sex with men (MSM). Despite guidelines recommending chlamydia retesting three months after treatment, retesting rates are low. We are conducting the first randomised controlled trial to assess the effectiveness of home collection combined with short message service (SMS) reminders on chlamydia retesting and reinfection rates in three risk groups. The REACT (retest after Chlamydia trachomatis) trial involves 600 patients diagnosed with chlamydia: 200 MSM, 200 women and 200 heterosexual men recruited from two Australian sexual health clinics where SMS reminders for retesting are routine practice. Participants will be randomised to the home group (3-month SMS reminder and home-collection) or the clinic group (3-month SMS reminder to return to the clinic). Participants in the home group will be given the choice of attending the clinic if they prefer. The mailed home-collection kit includes a self-collected vaginal swab (women), UriSWAB (Copan) for urine collection (heterosexual men), and UriSWAB plus rectal swab (MSM). The primary outcome is the retest rate at 1-4 months after a chlamydia diagnosis, and the secondary outcomes are: the repeat positive test rate; the reinfection rate; the acceptability of home testing with SMS reminders; and the cost effectiveness of home testing. Sexual behaviour data collected via an online survey at 4-5 months, and genotyping of repeat infections, will be used to discriminate reinfections from treatment failures. The trial will be conducted over two years. An intention to treat analysis will be conducted. This study will provide evidence about the effectiveness of home-collection combined with SMS reminders on chlamydia retesting, repeat infection and reinfection rates in three risk groups. The trial will determine client acceptability and cost effectiveness of this strategy. Australian and New

  18. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  19. Technetium {sup 99m}Tc Pertechnetate Brain Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi [Capital Army Hospital, ROKA, Seoul (Korea, Republic of); Rhee, Chong Heon; Koh, Chang Soon [Radiological Research Institute, Seoul (Korea, Republic of)

    1968-03-15

    Technetium {sup 99}mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or {sup 131}I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced {sup 99}mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  20. 99mTc-diethyl-IDA chloescintigraphy

    International Nuclear Information System (INIS)

    Kim, J. W.; Oh, K. C.; Bae, B. H.; Kim, Y. S.; Park, B. H.

    1981-01-01

    For many years, 131 I-rose bengal has been used as the main hepatobiliary radiopharmaceutical. The undesirable physical characteristics of the radioiodine, however, finally prevented its widespread use in clinical medicine. In recent years, a number of hepatobiliary radiopharmaceuticals employing 99m Tc and 123 I as indicator have been introduced. 99m Tc-diethyl-IDA is a most promising one in these agents. Cholescintigraphy, using 99m Tc-diethyl-IDA was performed in 10 normal subjects and 32 patients suffering from various hepatobiliary disturbances, from Sep. -'79 to Aug-' 80, at the department of radiology, Maryknoll Hospital. The following results are obtained: 1. In normal fasting subjects, the liver, GB, CBD, and the proximal portion of small bowel are clearly delineated within 30 min after the injection. After a fatty meal, the radioactivity of the liver and CBD is notably disappeared with increase of the activity in GB and small bowel. 2. A dilatation of the main biliary ducts is a pathognomomic sign of partial mechanical obstructive disorders and a key point of D.Dx from hepatocellular disorders. 3. In cases of complete biliary obstruction, the radioactivity of the liver, CBD, and small bowel is not separated and the background activity is markedly increased. The kidneys are well visualized. 4. In severe hyperbilirubinaemia of above 10mg%, this method is not valuable

  1. Mechanisms of conventional and high Tc superconductivity

    International Nuclear Information System (INIS)

    Kresin, V.L.; Morawitz, H.; Wolf, S.A.

    1993-01-01

    This book gives a careful and objective review of theories of superconductivity in traditional superconductors, organics, and high Tc cuprates. Of course, the authors do still present their own theories of cuprate superconductivity, but only in the final chapter after other possibilities have been discussed. The book should be especially useful for researchers entering the field of high Tc superconductivity. The reviews of photon mediated pairing and strong coupling theory are very welcome, since much of this material has not been reviewed since the classic 1969 volume edited by Parks. In particular the authors dispel the various myths that phonon mediated pairing leads to upper bounds on Tc. In addition to phonon mediated pairing the book discussed in detail pairing due to exchange of acoustic (demon) plasmons, excitons, or magnetic fluctuations. There have been so many diverse mechanisms based on strong correlation and large U Hubbard models that a book like this can only discuss a limited selection of the main contenders. In particular here the emphasis on Fermi liquid based models no doubt reflects the authors' own point of view. A whole chapter discusses the concepts of induced superconductivity, in the proximity effect, and its application to materials with several different electronic subsystems

  2. Fabrication of multifunctional CaP-TC composite coatings and the corrosion protection they provide for magnesium alloys.

    Science.gov (United States)

    Tan, Cui; Zhang, Xiaoxu; Li, Qing

    2017-08-28

    Two major problems with magnesium (Mg) alloy biomaterials are the poor corrosion resistance and infection associated with implantation. In this study, a novel calcium phosphate (CaP)/tetracycline (TC) composite coating for Mg implants that can both improve the corrosion resistance of Mg and release a drug in a durable way is reported. Scanning electron microscope (SEM) images showed that TC additives make the CaP coating more compact and uniform. Electrochemical tests indicated CaP/TC coatings can provide excellent corrosion protection for Mg alloy substrates. Besides, TC additives can also provide effective prevention of bone infection and inflammation due to its broad-spectrum antibacterial properties. The one-step hydrothermal process reported here greatly simplified the multi-step fabrication of smart coatings reported previously.

  3. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  4. Results of toxicity tests and chemical analyses conducted on sediments collected from the TNX Outfall Delta Operable Unit, July 1999

    International Nuclear Information System (INIS)

    Specht, W.L.

    2000-01-01

    In order to provide unit specific toxicity data that will be used to address critical uncertainty in the ecological risk assessment (ERA) for the TNX Outfall Delta Operable Unit (TNXOD OU), sediments were collected from eight locations in the Inner Swamp portion of the operable unit and two unit specific background locations. These samples were analyzed for total mercury, total uranium, and sediment toxicity

  5. Tumor affinity of technetium-99m labeled radiopharmaceuticals. II. Sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA), sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, K; Kobayashi, S; Hisada, K; Tonami, N [Kanazawa Univ. (Japan). School of Medicine; Ando, A

    1976-10-01

    The authors have examined the tumor affinity of various sup(99m)Tc-labelled radiopharmaceuticals to Ehrlich's tumor for the purpose of delineating human malignant neoplasm positively. The biologic distributions of sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA) and sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP, sup(99m)Tc-Honvan) are included as the second report on the tumor affinity of Ehrlich-bearing mice. Tumor concentration of sup(99m)Tc-EHDP was lowest and the positive delineation of implanted tumor with sup(99m)Tc-EHDP was poorest in sequential images, though active accumulation in some soft tissues malignant neoplasms, breast cancer, and thyroid cancer, has been reported. Tumor concentration and the tumor-to-blood ratio of sup(99m)Tc-DMSA were not so high, contrary to our expectation that /sup 197/Hg-DMSA might show high tumor concentration and high tumor-to-blood ratio the same as /sup 197/Hg chlormerodrin of the renal scanning radiopharmaceuticals. Tumor concentration of sup(99m)Tc-DSDP was highest. The tumor-to-blood concentration ratio was lower than that of the above mentioned radiopharmaceuticals but the tumor-to-liver ratio and/or tumor-to-lung ratio was over 1.0 at the earlier time. Biologic distribution of sup(99m)Tc-DSDP was similar to that of /sup 32/P labeled DSDP. It is presumed that sup(99m)Tc is labeled at the phosphate ester of DSDP which is dephospholytated immediately by phospholylase in vivo following intravenous injection. Although it is not known precisely it may be assumed that the mechanism of accumulating sup(99m)Tc-DSDP in Ehrlich's tumor is related to the phospholylase activity in neoplasms.

  6. Effect of Cimetidine and Gastric Acidity on the Gastric Mucosal Retention of 99mTc-Pertechnetate in Rate

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Kim, Jong Woo; Baik, Yong Whee

    1989-01-01

    99m Tc-Pertechnetate (TcO 4 - ) is concentrated by the stomach after intravenous injection, allowing the detection of ectopic gastric mucosa. It has been used to develop a noninvasive test of gastric secretion. However the cellular site of concentration is still controversial, that is whether mucin-secreting epithelial cell or acid-secreting parietal cell. This study is planned to investigate the effects of cimetidine and gastric acidity on the retention of TcO 4 - in the gastric wall of the rat. Also we further attempted to clarify the uptake and secreting cell of TcO 4 - in the gastric mucosa. One hundred rats were divided into two groups, preliminary (40 rats) and main examination group (60 rats). Preliminary examination group was composed of fasting group (20 rats) for the detection of the time for reaching stable TcO 4 - retention ratio in gastric wall and post-prandial group (20 rats) for the detection of the time for reaching the maximal gastric acidity. Main examination group was composed of fasting group (30 rats), which was subdivided into control group (10 rats), cimetidine group (10 rats), Mylanta group (10 rats) and post-prandial group (30 rats), which was subdivided into 90 min group (10 rats), 90 min cimetidine group (10 rats), and 120 min group (10 rats). Retention ratio (%) of TcO 4 - in the gastric wall and the pH of the gastric contents were measured in the extracted stomach of the six groups. Gastric wail retention ratio of TcO 4 - was calculated by the gastric wall radioactivity (cpm) divided by total gastric radioactivity (cpm) at 30 mins after intravenous injection of 0.4 mCi of TcO 4 - . The results were as follows: 1) The time required for reaching stable TcO 4 - retention ratio and the lowest gastric pH were 30 min and 90 min, respectively. 2) In the fasting group, the gastric wall retention ratio of TcO 4 - was significantly increased in the cimetidine group, compared with the control group (P 4 - retention ratio and gastric pH were well

  7. Biogeochemical Coupling of Fe and Tc Speciation in Subsurface Sediments: Implications to Long-Term Tc Immobilization

    International Nuclear Information System (INIS)

    Jim K. Fredrickson; C. I. Steefel; R. K. Kukkadapu; S. M. Heald

    2006-01-01

    The project has been focused on biochemical processes in subsurface sediments involving Fe that control the valence state, solubility, and effective mobility of 99Tc. Our goal has been to understand the Tc biogeochemistry as it may occur in suboxic and biostimulated subsurface environments. Two objectives have been pursued: (1) To determine the relative reaction rates of 99Tc(VII)O2(aq) with metal reducing bacteria and biogenic Fe(II); and to characterize the identity, structure, and molecular speciation of Tc(IV) products formed through reaction with both biotic and abiotic reductants. (2) To quantify the biogeochemical factors controlling the reaction rate of O2 with Tc(IV)O2?nH2O in sediment resulting from the direct enzymatic reduction of Tc(VII) by DIRB and/or the reaction of Tc(VII) with the various types of biogenic Fe(II) produced by DIRB

  8. Comparison of sup(99m)Tc-MDP to sup(99m)Tc-pertechnetate by computerized quantitative joint scintigraphy

    International Nuclear Information System (INIS)

    Rekonen, A.; Moettoenen, T.; Oka, M.

    1982-01-01

    99mTc-pertechnetate was compared to 99mTc-MDP in joint pairs with asymmetric arthritis. Markedly elevated joint activity ratios (inflamed/uninflamed joint) were measured in all the joint pairs studied. In the joints affected by reactive arthritis and without roentgenologic changes the mean joint activity was the same with both tracers. A very high activity ratio with 99mTc-MDP was found in septic arthritis. In rheumatoid arthritis the sensitivity of 99mTc-MDP as an indicator of active arthritis seemed to be better than that of 99mTc-pertechnetate. Even in joints without erosions in roentgenograms the joint activity ratios were markedly elevated with 99mTc-MDP. This suggests, that high activity in 99mTc-MDP scanning might be prognostic of erosive joint changes. In this work a profile curve was used for quantitation differences between joints

  9. Clinical evaluation of Tc-99m-mebrofenin and comparison with Tc-disofenin for radionuclide hepatobiliary imaging

    International Nuclear Information System (INIS)

    Klingensmith, W. III; Fritzberg, A.; Spitzer, V.

    1982-01-01

    The clinical comparison reported indicates that Tc-mebrofenin has a significantly lower level of renal excretion that Tc-disofenin at all bilirubin levels. At a total bilirubin level of 25 mg/dl the renal excretion of Tc-mebrofenin is still less than the renal excretion of Tc-disofenin in subjects with normal bilirubin levels. In addition, renal radioactivity in images was never seen in subjects with normal bilirubins while visualization of renal radioactivity is routine in normal subjects with Tc-disofenin. No significant differences were found in any other parameter including hepatocyte extraction efficiency, time of maximum hepatic radioactivity, and hepatic parenchymal washout. This study indicates that Tc-mebrofenin is equal to Tc-disofenin in its hepatobiliary characteristics and superior in its renal characteristics

  10. Lung scintigraphy with nonspecific human immunoglobulin G (99mTc-HIG) in the evaluation of pulmonary involvement in connective tissue diseases: correlation with pulmonary function tests (PFTs) and high-resolution computed tomography (HRCT)

    International Nuclear Information System (INIS)

    Kostopoulos, C.; Toubanakis, C.; Mamoulakis, C.; Gialafos, E.; Mavrikakis, M.; Koutsikos, J.; Zerva, C.; Leondi, A.; Moulopoulos, L.A.; Sfikakis, P.P.

    2008-01-01

    In patients with connective tissue diseases (CTD), the early detection and evaluation of the severity of the pulmonary involvement is mandatory. High-resolution computed tomography (HRCT) and pulmonary function tests (PFTs) are considered to be valuable noninvasive diagnostic modalities. Radiopharmaceuticals have also been used for this purpose. Our aim was the evaluation of technetium-labeled human polyclonal immunoglobulin G (HIG) lung scintigraphy in the early detection and assessment of the severity of the pulmonary involvement in CTD patients. Fifty-two nonsmoking CTD patients were studied by PFTs, HRCT, and HIG. According to PFTs, patients were divided in group A (impaired PFTs - abnormal pulmonary function) and group B (normal pulmonary function). Semiquantitative analysis was done on HIG and HRCT and corresponding scores were obtained. Significant difference was found between HIG scores in the two groups (0.6 ± 0.07 vs 0.51 ± 0.08, P < 0.001). There was a statistically significant negative correlation between HIG scores and PFTs results and a positive correlation between HIG and HRCT scores. HIG demonstrated similar clinical performance to HRCT. At the best cut-off levels of their score (0.56 and 7, respectively), HIG had a superior sensitivity (77.5 vs 57.5%) with lower specificity (75 vs 91.7%). The combination of the two methods increased the sensitivity of abnormal findings at the expense of specificity. HIG scintigraphy can be used in the early detection and evaluation of the severity of the pulmonary involvement in CTD, whereas, when used in combination with HRCT, the detection of affected patients can be further improved. (orig.)

  11. Role of 99mTc-MIBI in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Laghari, Naeem Ahmed; Anees, Mohammad

    2004-01-01

    Full text: Breast carcinoma is the most frequently diagnosed malignancy in women with 41% of all new cases diagnosed in developing countries. Over 323,000 women in the developing countries were detected in 1990, leading to 140,000 deaths. The annual incidence of breast carcinoma among women in Pakistan accounts for 32% of all detected carcinomas and 18% of all cancer related deaths. Three years data (2000-2002) collected from Bahawalpur Institute of Nuclear Medicine and Oncology (BINO) indicated that 16.5% of the total patients were registered with carcinoma breast. To reduce the mortality associated with this disease, screening of asymptomatic women has been advocated to diagnose problems at an early stage, particularly by X-ray mammography on annual basis after the age of 50. The available imaging modalities like mammography and ultrasound lack the desired specificity to differentiate the malignant masses from benign ones; hence there is a need to search for more specific imaging tool and to save the patients from unnecessary biopsies. Technetium-99m labeled methoxy-isobutyl-isonitrile (99mTc-MIBI) is a well-known cardiac perfusion-imaging agent. After convincing reports from various parts of the world that it specifically accumulates in malignant breast masses, we carried out a study to evaluate the diagnostic performance of 99mTc-MIBI scintimammography in palpable breast lesions. Patients with palpable breast lesions were studied after obtaining informed written consent. The study was carried out as a prospective trial. A total of 42 patients with 45 palpable breast masses were included in this study. The median age was 44 years (range 19-84 years). Tc-99m-MIBI was injected in a dose of 740 MBq in dorsal pedal vein and if unsuccessful then in medial cubital vein on the opposite side of the breast, to be imaged for the lump. Planar 10 minutes images in prone lateral and in supine position with arms raised behind the head were acquired 10 minutes and 60-90 minute

  12. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    International Nuclear Information System (INIS)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.; Barker, K.K.; Ice, R.D.

    1982-01-01

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated with other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate

  13. Rice uptake and leaching of {sup 99}Tc in different paddy soils contaminated according to two contrasting scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Ho; Lim, Kwang Muk; Jun, In; Kim, Byung Ho; Keum, Dong Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    Four different paddy soils collected around the Gyeongju nuclear site were treated with {sup 99}TcO{sub 4}{sup -1} solution under the assumption of two contrasting contamination scenarios. Scenario I (SN-I) is for a pre-transplanting deposition of {sup 99}Tc followed by plowing, whereas SN-II is for its deposition onto the water surface shortly after transplanting. Rice plants were grown in lysimeters in a greenhouse. Plant uptake of {sup 99}Tc was quantified with the TF{sub area} (m{sup 2}·kg{sup -1}-dry). The SN-II values for straws and brown rice, having been generally higher than the SN-I values, were within the ranges of 6.9x10{sup -3}⁓4.1x10{sup -2} and 5.2x10{sup -6}⁓7.3x10{sup -5}, respectively. Sorption onto clay seems to have decreased {sup 99}Tc uptake in SN-I, whereas it may have had an insignificant effect in SN-II. A phenomenon characteristic of submerged paddy soil, i.e., the development of a thin oxic surface layer may have greatly affected the rice uptake of SN-II {sup 99}Tc. The surface-water concentrations of {sup 99}Tc were much higher in SN-II than in SN-I. For the percolating water, however, the opposite was generally true. At most 1.3% of the applied {sup 99}Tc were leached through such percolation. The use of empirical deposition time-dependent TF{sub area} values was considered desirable in assessing the radiological impact of a growing-season deposition of {sup 99}Tc onto paddy fields.

  14. ICP-MS as advantageous analytical technique for the determination of long-lived /sup 99/Tc in the environment

    International Nuclear Information System (INIS)

    Ihsanullah

    1992-05-01

    Technetium (Tc) was the first artificially created by man and has no stable isotope. The most crucial technetium isotope environmentally /sup 99/Tc is a pure beta emitter with a half-life of 2.1 X 105 years. The main source of /sup 99/Tc to the environment is the disposal of liquid wastes from nuclear installations or during separation and recovery of spent nuclear fuels. Because of its long half life, high fission yield, mobility and current interest in the collective long term doses, it is necessary to establish a knowledge of the behavior of /sup 99/Tc in the environment for complete assessment of the impact of nuclear industry. Due to various analytical difficulties however, data on the behavior of Tc in the environment are limited. In the literature, many techniques are reported for the analysis of Tc. A very sensitive, precise and powerful technique is required which can be applied to environmental samples in order to gain information by obtaining more precise data to assess the impact of Tc releases on man. Attention has been focussed for this purpose on a new powerful technique i.e. inductively coupled plasma mass spectrometry (ICP-MS). This report has been directed towards the development of ICP-MS. The technique gives a very high sensitivity enabling long lived radionuclides including /sup 99/Tc to be measured directly down to pg ml-1 levels in solution. Because of its versatility ICP-MS is finding applications for trace multielement analysis and low detection limits in almost all fields. (author)

  15. Development of 99mTc labelled somatostatin analogues and evaluation of their radiochemical and biological behaviour

    International Nuclear Information System (INIS)

    Gano, L.; Patricio, L.

    2001-01-01

    Conjugates of two somatostatin analogues, octreotide and RC-160, with HYNIC were synthesized, characterized and purified by reverse phase HPLC. Radiolabelling of the conjugates with 99m Tc was achieved using tricine as co-ligand. High labelling efficiencies were obtained and 99m Tc peptides with high radiochemical purity were found when analysed both by ITLC and HPLC. In vitro stability of 99m Tc-peptides in human serum and towards cysteine challenge was determined by Cellogel electrophoresis and HPLC after ultrafiltration of serum solution through a 20 kDa cut off membrane. Biodistribution studies were performed in healthy mice at 5 and 30 minutes and 1, 2, 4 and 24 h post-injection. Urine and blood samples were collected at sacrifice time. Samples of urine and ultrafiltrate murine serum were analysed by electrophoresis and reverse phase HPLC in order to get some information about radiocompounds metabolism. Biological distribution of 99m Tc octreotide was also assayed in mice pre-treated with an excess of unlabelled peptide. From our results we conclude that this labelling method led to stable 99m Tc complexes both in vitro and in vivo when high specific activities (37-72 GBq/μmole) were used. Biodistribution studies of both 99m Tc-peptides indicated a radioactivity distribution profile with significant differences especially in the liver uptake that is higher for 99m Tc RC-160. However, a rapid blood clearance was obtained for both radiolabelled peptides, and the urine analysis indicated that 99m Tc peptide is mostly excreted as the initial complex. Pre-treatment with unlabelled peptide did not affect renal excretion of 99m TOC but pancreas and intestine radioactive uptake was significantly lower, indicating saturation of somatostatin receptors and selective uptake. (author)

  16. The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime

    International Nuclear Information System (INIS)

    Berman, D.S.; Kiat, H.; Maddahi, J.

    1991-01-01

    The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and 99mTc-Teboroxime, are now available for routine clinical application. Both agents allow assessment of ejection fraction by the first-pass technique at rest or during exercise, thus providing additional information not available with thallium-201. 99mTc-Sestamibi has long myocardial residence time, as well as adequate myocardial extraction, providing images of higher count density and superior quality compared with thallium-201. 99mTc-Teboroxime has excellent myocardial uptake characteristics but is cleared very rapidly from the myocardium. Both tracers have shown results similar to those obtained with thallium-201 for detection of coronary artery disease and the assessment of defect reversibility. 99mTc-Sestamibi studies using the rest/stress imaging sequence can be accomplished in approximately 5 hours; studies using dual-isotope imaging (rest thallium-201 and stress 99mTc-Sestamibi injection) can be completed in 1 to 2 hours. Gated stress images can be performed with 99mTc-Sestamibi, providing simultaneous information of myocardial perfusion at stress and resting wall motion or thickening and allowing rapid differentiation of ischemic from infarcted tissue. Because of its slow myocardial clearance and absence of redistribution, 99mTc-Sestamibi allows uncoupling of the time of injection from the time of imaging and thus can be valuable in the evaluation of acute myocardial infarction and outcome of thrombolytic therapy. With 99mTc-Teboroxime, rapid serial studies are feasible. Pharmacologic stress and rest studies with 99mTc-Teboroxime single photon emission computed tomography potentially can be completed in under 30 minutes. 73 references

  17. Characterization of natural titanomagnetites (Fe3-xTixO4) for studying heterogeneous electron transfer to Tc(VII) in the Hanford subsurface

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Carolyn I.; Liu, Juan; Baer, Donald R.; Qafoku, Odeta; Heald, Steve M.; Arenholz, Elke; Grosz, Andrew E.; McKinley, James P.; Resch, Charles T.; Bowden, Mark E.; Engelhard, Mark H.; Rosso, Kevin M.

    2014-03-01

    Sediments with basaltic provenance, such as those at the Hanford nuclear reservation, Washington, USA, are rich in Fe-bearing minerals of mixed valence. These minerals are redox reactive with aqueous O2 or Fe(II), and have the potential to react with important environmental contaminants including Tc. Here we isolate, identify and characterize natural Fe(II)/Fe(III)-bearing microparticles from Hanford sediments, develop synthetic analogues and investigate their batch redox reactivity with aqueous Tc(VII). Natural Fe-rich mineral samples were isolated by magnetic separation from sediments collected at several locations on Hanford’s central plateau. This magnetic mineral fraction was found to represent up to 1 wt% of the total sediment, and be composed of 90% magnetite with minor ilmenite and hematite, as determined by X-ray diffraction. The magnetite contained variable amounts of transition metalsconsistent with alio- and isovalent metal substitutions for Fe. X-ray microprobe analysis showed that Ti was the most significant substituent, and that these grains could be described with the titanomagnetite formula Fe3_xTixO4, which falls between endmember magnetite (x = 0) and ulvo¨ spinel (x = 1). The dominant composition was determined to be x = 0.15 by chemical analysis and electron probe microanalysis in the bulk, and by L-edge X-ray absorption spectroscopy and X-ray photoelectron spectroscopy at the surface. Site-level characterization of the titanomagnetites by X-ray magnetic circular dichroism showed that despite native oxidation, octahedral Fe(II) was detectable within 5 nm of the mineral surface. By testing the effect of contact with oxic Hanford and Ringold groundwaters to reduced Ringold groundwater, it was found that the concentration of this near-surface structural Fe(II) was strongly dependent on aqueous redox condition. This highlights the potential for restoring reducing equivalents and thus reduction capacity to oxidized Fe-mineral surfaces through

  18. Internal friction around Tc connected with superconductivity in high Tc superconductors

    International Nuclear Information System (INIS)

    Wang Yening

    1993-01-01

    Internal friction and ultrasonic measurements show that there always exists a phase-like transition (PLT) characterized by the jump of lattice parameters at tens degrees above Tc in superconducting YBaCuO, BiSrCaCuO and TlBaCaCuO. Ferroelastic loops and shape memory effect associated with elastic softening invariably occur at the PLT temperature, showing the characteristics of thermoelastic martensitic transition. Internal frictions in KHz of Bi(Pb)SrCaCuO reveal a static hysteretic plateau (Qp -1 ) above Tc that drops linearly with temperature below Tc. The Qp -1 of YBaCuO decreases with decreasing oxygen content. The origin of the hysteretic Qp -1 is attributed to the lattice distortions around the carriers. (orig.)

  19. Bioavailability of {sup 99m}Tc-paclitaxel-glucuronide ({sup 99m}Tc-PAC-G)

    Energy Technology Data Exchange (ETDEWEB)

    Biber Muftuler, F.Z.; Demir, I.; Uenack, P.; Ichedef, C.; Yurt Kilcar, A. [Ege Univ., Izmir (Turkey). Dept. of Nuclear Applications

    2011-07-01

    An antitumor agent paclitaxel (PAC) has been proved to be efficient in the treatment of breast and ovarian cancer. Glucuronic acid-derived paclitaxel compound (paclitaxel-glucuronide (PAC-G)) was enzymatically synthesized using microsome preparate separated from rat livers. The biodistribution mechanism of PAC-G in healthy female Albino Wistar rats has been investigated. The expected structure is confirmed according to LC/MS results, and the possible attachment is to C2-hydroxyl group. PAC-G was labeled with {sup 99m}Tc and the radiochemical yield of radiolabeled compound ({sup 99m}Tc-PAC-G) was 98.0 {+-} 02.74% (n=9). The range of the breast/blood and breast/muscle ratios is approximately between 3 and 35 in 240 min. All these experimental studies indicate that {sup 99m}Tc-PAC-G may potentially be used in breast tissue as an imaging agent. (orig.)

  20. Exafs studies of coprecipitation and adsorption reactions of Tc

    Energy Technology Data Exchange (ETDEWEB)

    Bunker, D.J.; Jones, M.J.; Livens, F.R.; Collison, D. [Manchester Univ. (United Kingdom). Dept. of Chemistry; Pattrick, R.A.D. [Manchester Univ., Dept. of Earth Sciences (United Kingdom); Charnock, J.M. [CLRC Daresbury Laboratoire, Warrington Cheshire (United Kingdom)

    2000-07-01

    Adsorption and coprecipitation reactions may be a simple way of removing [TcO{sub 4}]{sup -} from aqueous solution. The effectiveness of a range of potential adsorbents and precipitants has been evaluated and some are capable of near quantitative (>98%) removal of [TcO{sub 4}){sup -} from solution. X-ray absorption near edge structure (XANES) has been used to determine Tc oxidation states and extended X-ray absorption fine structure spectroscopy (EXAFS) has been used to identify the local environment of Tc. The absorption edge position has been determined, using [PPh{sub 4}][TcO{sub 4}], TcS{sub 2} and Tc{sub 2}S{sub 7} as model compounds, and is diagnostic of Tc oxidation state. In a series of experiments investigating FeS coprecipitation, Tc was reduced to oxidation state (IV) and its local environment resembled that in TcO{sub 2} (6 O atoms at approximately 2.0 Angstrom). (authors)

  1. Studies of the Tc oxidation states in humic acid solutions

    International Nuclear Information System (INIS)

    Wang Bo; Liu Dejun; Yao Jun

    2010-01-01

    The oxidation state is an important aspect of the speciation of Tc in groundwater that contained organic substances due to it control the precipitation, complexation, sorption and colloid formation behavior of the Tc under HWL geological disposal conditions. In present work, the oxidation states of Tc were investigated using the LaCl 3 coagulation method and solution extraction method in aqueous solutions in which the humic acid concentration range is from 0 to 20 mg L -1 and the Tc (Ⅶ) concentration range is about 10 -8 mol l -1 . The radiocounting of 99 Tc was determined using liquid scintillation spectrometry. The humic acid will influence the radiocounting ratio of 99 Tc apparently, however, the quenching effect can be restrained once keep the volume of the cocktail to about twenty times of the sample volume. The LaCl 3 coagulation methods were carried out for the investigation of Tc oxidation states in humic acid aqueous systems at about pH 8. The tetraphenylarsonium chloride (IPA)-chloroform extraction method was used also simultaneously to investigation the concentrations of Tc (Ⅳ) and Tc (Ⅶ) for the availability of the LaCl 3 precipitation method, and the experimental results demonstrate that tetravalent technetium and pertechnetate concentrations are well agreement with the LaCl 3 precipitation method. These two experimental results demonstrated that Tc (Ⅶ) is very stable in the Tc (Ⅶ)-humic acid system during a 350 days experimental period, and the Tc (Ⅳ) concentrations are very lower, that is indicate that there didn't oxidizing reactions between the Fluka humic acid and Tc (Ⅶ) in aqueous solutions under anaerobic conditions. That is means the presence of humic acids even in anaerobic groundwater is disadvantage for the retardance of radionuclides. (authors)

  2. Studies of Tc oxidation states in humic acid solutions

    International Nuclear Information System (INIS)

    Wang Bo; Liu Dejun; Yao Jun

    2011-01-01

    The oxidation state of Tc is an important aspect of the speciation in groundwater which contained organic substances due to it control the precipitation, complexation, sorption and colloid formation behavior of the Tc under HWL geological disposal conditions. In present work, the oxidation states of Tc were investigated using the LaCl 3 coagulation method and solution extraction method in aqueous solutions in which the humic acid concentration range is from 0 to 20 mg/L and the Tc (VII) concentration is about 10 -8 mol/L. The radiocounting of 99 Tc was determined using liquid scintillation spectrometry. The humic acid will influence the radiocounting ratio of 99 Tc apparently, however, the quenching effect can be restrained once keep the volume of the cocktail to about twenty times of the sample volume. The LaCl 3 coagulation method was carried out for the investigation of Tc oxidation states in humic acid aqueous systems at about pH 8. The tetraphenylarsonium chloride (TPA)-chloroform extraction method was used also simultaneously to investigation the concentrations of Tc (IV) and Tc (VII) for the availability of the LaCl 3 precipitation method, and the experimental results demonstrate that tetravalent technetium and pertechnetate concentration are well agreement with the LaCl 3 precipitation method. These two experimental results demonstrated that Tc (VII) is very stable in the Tc (VII)-humic acid system during a 350 days experimental period, and the Tc (IV) concentrations are very lower, that is indicate that there didn't oxidizing reactions between the Fluka humic acid and Tc (VII) in aqueous solutions under anaerobic conditions. That means the presence of humic acids even in anaerobic groundwater is disadvantage for the retardance of radionuclides. (authors)

  3. Radiochemical data collected on events from which radioactivity escaped beyond the borders of the Nevada test range complex

    International Nuclear Information System (INIS)

    Hicks, H.G.

    1981-01-01

    This report identifies all nuclear events in Nevada that are known to have sent radioactivity beyond the borders of the test range complex. There have been 177 such tests, representing seven different types: nuclear detonations in the atmosphere, nuclear excavation events, nuclear safety events, underground nuclear events that inadvertently seeped or vented to the atmosphere, dispersion of plutonium and/or uranium by chemical high explosives, nuclear rocket engine tests, and nuclear ramjet engine tests. The source term for each of these events is given, together with the data base from which it was derived (except where the data are classified). The computer programs used for organizing and processing the data base and calculating radionuclide production are described and included, together with the input and output data and details of the calculations. This is the basic formation needed to make computer modeling studies of the fallout from any of these 177 events

  4. Study of the viability of hydroxyapatite as matrix of the generator 99 Mo/99m Tc

    International Nuclear Information System (INIS)

    Aguilar D, I.C.; Badillo A, V.E.; Monroy G, F.

    2004-01-01

    The generator more used in the nuclear medicine it is the generator 99 Mo / 99 Tc. The separation of 99 Mo and 99m Tc in the commercial generator is carried out on a column that contains alumina (Al 2 0 3 ). The adsorbent proposed in this investigation work, the hydroxyapatite, is an insoluble solid considered within of the fixers of anions more important. To evaluate the efficiency of the hydroxyapatite in the separation of the Mo and the Tc they were carried out preliminary tests to know the likeness of the one been accustomed to by the molybdate ions (MoO 4 -2 ) and the pertechnetate ions (Tc0 4 - ) in function of the value of the p H, in a solution of CaCI 2 0.01 M. For the study of the retention of the molybdate ion, it was used the radioisotope Mo-99 fission product, and for the pertechnetate ion it was used the Tc- 99 m radionuclide son of the Mo-99. The obtained results in a solution of CaCl 2 0.01 M to different values of p H of the solution, show that the fixation of the pertechnetate ions (TcO 4 - ) and the fixation of the molybdate ions (MoO 4 -2 ), they present very different behaviors in the hydroxyapatite. The results indicate that the synthetic hydroxyapatite BIO-RAD retains to the molybdate ion to values of lightly acid p H (5-6), being the retention of the pertechnetate practically worthless. (Author)

  5. Imaging human atherosclerosis with /sup 99m/Tc-labeled low density lipoproteins

    International Nuclear Information System (INIS)

    Lees, A.M.; Lees, R.S.; Schoen, F.J.; Isaacsohn, J.L.; Fischman, A.J.; McKusick, K.A.; Strauss, H.W.

    1988-01-01

    The feasibility of localizing human atherosclerotic plaques by gamma scintillation camera external imaging with technetium-99m-labeled low density lipoproteins (99mTc-LDL) was tested in 17 patients who had atherosclerosis. Imaging demonstrated focal accumulation of radiolabel consistent with 99mTc-LDL sequestration by plaques in the carotid, iliac, or femoral vessels of four patients 8 to 21 hours after intravenous injection of the radiopharmaceutical. Focal accumulation of 99mTc-LDL also appeared in the location of coronary lesions in four patients, but this accumulation could not be distinguished with certainty from residual blood pool radioactivity. When carotid endarterectomy specimens from six patients who received 99mTc-LDL 1 day before endarterectomy were examined, the specimens had focal accumulations of radiolabel, with two to four times greater radioactivity in some regions of each specimen than in others; this occurred whether or not the lesions were detected on the gamma camera images. Lesion composition may have determined whether accumulation was quantitatively sufficient to produce an external image. Histologically, the imaged carotid specimen had abundant foam cells and macrophages and poorly organized intramural blood consistent with a plaque hemorrhage; in contrast, nonimaged endarterectomy specimens were mature, fibrocalcific plaques. We conclude that: 1) 99mTc-LDL did accumulate in human atherosclerotic plaques; 2) in some patients, the accumulation of 99mTc-LDL was sufficient for detection by gamma camera imaging; 3) the amount of LDL that accumulated appeared to depend on lesion composition; and 4) the design of new radiopharmaceuticals with reduced residual blood pool activity relative to plaque accumulation should lead to improved external imaging of atherosclerosis

  6. Development of more efficacious Tc-99m organ imaging agents for use in nuclear medicine by analytical characterization of radiopharmaceutical mixtures. Progress report, May 1, 1982-April 30, 1983

    International Nuclear Information System (INIS)

    Heineman, W.R.; Deutsch, E.A.

    1982-11-01

    A procedure based on high performance liquid chromatography (HPLC) has been developed for separating individual Tc-diphosphonate complexes in skeletal-imaging radiopharmaceuticals prepared by reduction of TcO 4 - with NaBH 4 in the presence of methylene diphosphonate (MDP). Seven different Tc-MDP complexes have been detected and isolated in pure form. Significant differences in skeletal uptake and blood clearance are exhibited by the three complexes tested thus far by biodistribution studies in test animals. The relative quantities of these complexes present in a radiopharmaceutical preparation are dramatically influenced by the pH of the reaction mixture. Thus, control of pH is a simple means of forming in high yield the single, most efficacious Tc-MDP complex for skeletal imaginG. An HPLC method with electrochemical detection has been developed for the analytical determination of total TcO 4 - (/sup 99m/Tc + 99 Tc). Concentrations of TcO 4 - as low as 9 x 10 -9 M can be detected. The method is being evaluated for monitoring total TcO 4 - in 99 Mo//sup 99m/Tc generators

  7. Post meningitis subdural hygroma: Anatomical and functional evaluation with (99m)Tc-ehylene cysteine dimer single photon emission tomography/computed tomography.

    Science.gov (United States)

    Sharma, Punit; Mishra, Ajiv; Arora, Geetanjali; Tripathi, Madhavi; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Subdural hygroma is the collection of cerebrospinal fluid in the subdural space. Most often these resolve spontaneously. However, in cases with neurological complications surgical drainage may be needed. We here, present the case of an 8-year-old boy with post meningitis subdural hygroma. (99m)Tc-ehylene cysteine dimer ((99m)Tc-ECD) hybrid single photon emission tomography/computed tomography (SPECT/CT) carried out in this patient, demonstrated the subdural hygroma as well as the associated cerebral hypoperfusion. If (99m)Tc-ECD SPECT/CT is integrated into management of these patients, it can help in decision making with respect to conservative versus surgical management.

  8. Comparison of Tc-99m Ciprofloxacin (Infecton) and Tc-99m Methylene diphosphonate (MDP) three-phase bone scintigraphy in the diagnosis of osteomyelitis in patients with Sickle Cell Disease

    International Nuclear Information System (INIS)

    Bererhi, H.; Hussein, S.; Wali, Y.

    2003-01-01

    The high incidence of Sickle Cell Disease (SCD) is a major health problem in Oman. These patients are more prone to infections than the general population, and in particular, they are highly susceptible to osteomyelitis. Because bone infarction is more common than osteomyelitis in SCD, an accurate and rapid differential diagnosis is essential before initiating appropriate treatment. The present prospective study evaluates the usefulness of the new radiopharmaceutical, Tc- 99m Ciprofloxacin (Infecton) for the differential diagnosis of infection and infarction in patients with SCD. Majority of subjects studied were children. The results of Tc-99m Infecton imaging were compared with those of the 3-phase bone scintigraphy using Tc- 99m Methylene diphosphonate (Tc-99m MDP). Twenty-five patients referred for ruling out infection were imaged after intravenous injection of 5.5 MBq/kg body weight of Tc-99m Infecton. First pass, blood pool and late images (at one, four and 24 hours post injection) were performed. Subsequently all patients were also studied by three-phase bone scintigraphy using Tc-99m MDP. No adverse effects were observed. The sensitivity, specificity, accuracy and positive likelihood ratio of Tc-99m Infecton imaging for osteomyelitis were 100%, 92%, 94% and 12.5 respectively. Although bone scintigraphy would rarely be used by itself as a stand-alone test in the diagnosis of osteomyelitis in patients with SCD, its corresponding values were: 88%, 64%, 71% and 2.4. The results of this study suggest that the use of Tc-99m Infecton imaging is extremely beneficial in the management of patients of Sickle Cell Disease with suspected osteomyelitis. (author)

  9. Accumulation of 99Tc in duckweed Lemna minor L. as a function of growth rate and 99Tc concentration

    International Nuclear Information System (INIS)

    Hattink, J.; Wolterbeek, H.Th.

    2001-01-01

    This study focuses on the question of whether short-term studies can be used to forecast the accumulation of the long-lived fission product 99 Tc in duckweed, Lemna minor L., grown in the field; in other words, are the accumulation parameters independent of changing growth rates typical of natural populations of duckweed. Two processes determine the 99 Tc accumulation: (i) uptake and release of 99 TcO 4 - , characterised by a concentration factor, K d , and (ii) first-order reduction and complexation of Tc VII , characterised by k red . At various 99 Tc concentrations, the growth, total Tc and TcO 4 - accumulation were monitored over 10 days; parameters were fitted and compared with earlier results. Both K d and k red turn out to be independent of time, concentration and growth rate up to a concentration of 10 -6 mol l -1 99 TcO 4 - . Concentrations above this level result in toxic effects. The Tc accumulation in field populations of duckweed at Tc concentrations which generally occur in the environment can be forecasted by using the results from short-term experiments

  10. /sup 99m/Tc labeling of antibodies to cardiac myosin Fab and to human fibrinogen

    International Nuclear Information System (INIS)

    Khaw, B.A.; Strauss, H.W.; Carvalho, A.; Locke, E.; Gold, H.K.; Haber, E.

    1982-01-01

    We have developed a method of labeling biologically active labile macromolecules, such as human fibrinogen (HF) and anticardiac-myosin Fab (AM-Fab), with /sup 99m/Tc at neutral pH. This method uses dithionite reduction of pertechnetate and subsequent labeling, to test the method with acid-labile macromolecules. Complexes of diethylene triamine pentaacetic acid with macromolecules such as human fibrinogen (D-HF) and anticardiac-myosin Fab (D-AM-Fab) were labeled and utilized in in vitro and in vivo studies. In biodistribution studies, the /sup 99m/Tc D-HF had a two-component blood clearance (half-times 1 hr and 15 hr) and was 80--88% coagulable. The /sup 99m/Tc AM-Fab retained its immunoreactivity as tested by affinity chromatography; also during in vivo localization in experimental myocardial infarction. This labeling technique provides an easy and efficient approach to the /sup 99m/Tc labeling of other biologically active and acid-labile macromolecules

  11. Evaluation of Tc-99m leukocyte scan in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Butler, J.A.; Marcus, C.S.; Henneman, P.L.; Inkelis, S.H.; Wilson, S.E.

    1987-01-01

    A new /sup 99m/Tc Microlite leukocyte scan was performed in 38 patients to assess its value in the diagnosis of acute appendicitis. Autologous leukocytes are labeled with /sup 99m/Tc by inducing phagocytosis of /sup 99m/Tc albumin microcolloid particles. The advantages of this test over the standard indium-111 scan include superior imaging capability, a marked reduction (greater than 75%) in the radiation dose, and performance of the test including labeling, in less than 3 hr. Imaging is performed at 5-90 min postinjection of labeled cells. There were 19 male and 19 female patients with ages ranging from 10 to 80 years, in whom the diagnosis of appendicitis was indeterminate on clinical examination. Of the 13 of the 38 patients (34%) who came to surgery 12 had acute appendicitis. The WBC scan correctly identified 10 of the 12 cases of appendicitis. There were two false-negative studies. In the nonoperative group of 25 patients admitted for observation, 21 studies were reported as negative and four identified other sites of inflammation. All patients with a negative study have remained asymptomatic on follow-up. With a sensitivity of 83% (10/12) and a specificity of 100% (26/26) the /sup 99m/Tc leukocyte scan provides a rapid and highly accurate method for diagnosis of appendicitis in this preliminary study of patients with equivocal clinical exams

  12. Diagnosis of clinically unsuspected gallbladder perforation in an obese patient, by Tc-99m IDA cholescintigraphy

    International Nuclear Information System (INIS)

    Mesgarzadeh, M.; Haines, J.E.; Bobba, V.R.; Von Dollen, L.E.; Jarboe, G.; Krishnamurthy, G.T.

    1983-01-01

    A male Pickwickian syndrome patient was admitted to the hospital with sudden onset of abdominal pain. Physical examination was equivocal. Due to patient's ileus and morbid obesity (weight 450 lb), neither TCT scan nor ultrasound was possible. A Tc-99m PIPIDA hepatobiliary imaging study revealed intraperitoneal leakage of radioactive bile with collection of the activity in both abdominal gutters, indicating gallbladder rupture. Prompt surgery confirmed the diagnosis

  13. 99mTc-Tetrofosmin scintimammography in suspected breast cancer patients: comparison with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate the diagnostic role of 99m Tc-Tetrofosmin in detection of breast cancer and compared with that of 99m Tc-MIBI. Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had 99m Tc-MIBI and 99m Tc-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of 99m Tc-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-Tetrofosmin were 31, 10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of 99m Tc-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both 99m Tc-Tetrofosmin scintimammographies and its size was 0.5cm. 99m Tc-Tetrofosmin and 99m Tc-MIBI were non-invasive and useful in detection of breast cancer and 99m Tc-Tetrofosmin was comparable to the 99m Tc-MIBI in detection of primary breast cancer.=20

  14. Formation of a Tc(III)-adenosine diphosphate complex

    International Nuclear Information System (INIS)

    Torres, J.; Kremer, C.; Kremer, E.

    1995-01-01

    A 99 Tc-ADP complex was prepared when KTcO 4 was reduced in aqueous medium by SnCl 2 , Na 2 S 2 O 4 , NaBH 4 or Zn in the presence of ADP in excess. The resulting solution was studied by chromatography and spectrophotometry. Electrochemical reduction and substitution on [Tc III (tu) 6 ] 3+ were investigated as alternative synthetic routes. The anionic Tc-ADP complex was isolated as a solid. Cerimetric titrations confirmed the oxidation state +3 for the central atom. IR and 1 H-NMR data showed that the purine base is bonded to the Tc central atom but not the ribose moiety. No oxo groups seemed to be directly bonded to the Tc atom. The complex is rather stable in neutral solutions. However, it decomposes to pertechnetate and TcO 2 at extreme pH values. (author). 16 refs., 2 figs., 3 tabs

  15. A review of sup(99m)Tc generator technology

    International Nuclear Information System (INIS)

    Molinski, V.J.

    1982-01-01

    The sup(99m)Tc generator has found widespread use because it is ideally suited for scintigraphy. The preparation of sup(99m)Tc generators using alumina and other ion exchange systems is described. Other methods of separating 99 Mo and sup(99m)Tc, such as solvent extraction and sublimation, are also discussed. Some of the problems associated with the alumina column type sup(99m)Tc generator are listed with possible causes and solutions to their problems. The current biomedical applications of the sup(99m)Tc radioisotope are the basis of a $100 million nuclear medicine business. The importance of the sup(99m)Tc generator makes it imperative that we understand and solve the problems associated with its manufacture. (author)

  16. Can tumor uptake Tc-99m MDP ?

    International Nuclear Information System (INIS)

    Yand Shun, Fang; Yao, Ming; Zeng, Jun; Shi Zhen, Yu; Zhao Lan, Xiang; Dong Qiang, Gang

    2003-01-01

    To explore the mechanism of technetium-99m-methylene diphosphonate (MDP) uptake within tumor through analyze a distribution of Tc-99m MDP in mice bearing tumor cell lines. Methods: The uptake of Tc-99m MDP was analyzed in seven human tumor cell lines ( SPC-A1 adenocarcinoma of lung cancer, Bcap-37 Breast cancer, T-24 Bladder cancer, SKOV3 Ovary carcinoma, Hela-229 Cervical carcinoma, SCI-OS Osteosarcoma, SCI-375 Melanoma) and mouse Lewis lung cancer cell line. They were transplanted into athymic mice, SCID nude mice and C57BL/6 mice, respectively. Approximately 10(6) cells of each cell line were injected subcutaneously into a right chest of mouse. After 4 and 5 weeks, the Tc-99m MDP scintigraphy were determined 6 hours after tail vein injection of 74MBq in 0.05ml every mouse. Result: Biodistribution and tumor uptake MDP was different in the various cell types investigated. According to the Region Ratio program of Siemens Power Macintosh 9500 Computer System, region of interests (RIOs) placed on a small part of the tumor and horizontal copied to left background (T/B) and thoracic spine (T/N) of mice in Tc-99m MDP imaging. The average cpm/pixel ratios were calculated by standardized uptake measure (SUM) and determined the tumor-positive value (T/B) greater than or equal to 1.2. T/B of cell lines were sorted from higher to lower as follows: SCI-OS, Lewis, SKOV3, SCI-375, T-24, SPC-A1, Bcap-37, Hela-229. T/N: SCI-OS, SKOV3, T-24, SCI-375, Lewis, SPC-A1, Bcap-37, Hela-229. The biodistribution data of 99Tcm-MDP in SPC-A1 tumor-bearing BALB/c nude mice were given as ID/g and represent the means D (n=13) in 30 hours after injection of Tc-99m MDP. ID/g of major tissue were sorted from higher to lower as follows: thoracic spine, lumbar, ribs, kidneys, the center of tumor, the ulcer of tumor, the surrounding of tumor, lymph node, blood, lungs, heart, liver. Conclusions: Most of tumor can uptake Tc-99m MDP including human adenocarcinoma. The uptake rate in the center tissue of

  17. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    . Cardiac amyloidosis is often under diagnosed due to unspecific and varied signs and symptoms. The diagnosis is confirmed by endomyocardial biopsy, an invasive procedure with inherent risks to this technique. Pyrophosphate-{sup 99m}Tc scintigraphy is a simple, non-invasive, low cost, with good sensitivity method for detection of cardiac amyloidosis. The scintigraphy pattern observed in cardiac amyloidosis cases is abnormal diffuse tracer uptake in both heart ventricles. Planar and/or tomographic imaging may be performed. It is considered a highly sensitive test, with low rates of false-negative results despite the existing little literature. Therefore the scintigraphy can be useful to select patients for biopsy. Conclusion: Scintigraphy can be of great assistance in cardiac amyloidosis, despite its low specificity. Due to its high sensibility, it can be a useful test to early discriminate patients who should undergo biopsy, allowing treatment optimization. (author)

  18. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    International Nuclear Information System (INIS)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C.

    2008-01-01

    amyloidosis is often under diagnosed due to unspecific and varied signs and symptoms. The diagnosis is confirmed by endomyocardial biopsy, an invasive procedure with inherent risks to this technique. Pyrophosphate- 99m Tc scintigraphy is a simple, non-invasive, low cost, with good sensitivity method for detection of cardiac amyloidosis. The scintigraphy pattern observed in cardiac amyloidosis cases is abnormal diffuse tracer uptake in both heart ventricles. Planar and/or tomographic imaging may be performed. It is considered a highly sensitive test, with low rates of false-negative results despite the existing little literature. Therefore the scintigraphy can be useful to select patients for biopsy. Conclusion: Scintigraphy can be of great assistance in cardiac amyloidosis, despite its low specificity. Due to its high sensibility, it can be a useful test to early discriminate patients who should undergo biopsy, allowing treatment optimization. (author)

  19. Remote Sensing of Radiative and Microphysical Properties of Clouds During TC (sup 4): Results from MAS, MASTER, MODIS, and MISR

    Science.gov (United States)

    King, Michael D.; Platnick, Steven; Wind, Galina; Arnold, G. Thomas; Dominguez, Roseanne T.

    2010-01-01

    The Moderate Resolution Imaging Spectroradiometer (MODIS) Airborne Simulator (MAS) and MODIS/Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) Airborne Simulator (MASTER) were used to obtain measurements of the bidirectional reflectance and brightness temperature of clouds at 50 discrete wavelengths between 0.47 and 14.2 microns (12.9 microns for MASTER). These observations were obtained from the NASA ER-2 aircraft as part of the Tropical Composition, Cloud and Climate Coupling (TC4) experiment conducted over Central America and surrounding Pacific and Atlantic Oceans between 17 July and 8 August 2007. Multispectral images in eleven distinct bands were used to derive a confidence in clear sky (or alternatively the probability Of cloud) over land and ocean ecosystems. Based on the results of individual tests run as part of the cloud mask, an algorithm was developed to estimate the phase of the clouds (liquid water, ice, or undetermined phase). The cloud optical thickness and effective radius were derived for both liquid water and ice clouds that were detected during each flight, using a nearly identical algorithm to that implemented operationally to process MODIS Cloud data from the Aqua and Terra satellites (Collection 5). This analysis shows that the cloud mask developed for operational use on MODIS, and tested using MAS and MASTER data in TC(sup 4), is quite capable of distinguishing both liquid water and ice clouds during daytime conditions over both land and ocean. The cloud optical thickness and effective radius retrievals use five distinct bands of the MAS (or MASTER), and these results were compared with nearly simultaneous retrievals of marine liquid water clouds from MODIS on the Terra spacecraft. Finally, this MODIS-based algorithm was adapted to Multiangle Imaging SpectroRadiometer (MISR) data to infer the cloud optical thickness Of liquid water clouds from MISR. Results of this analysis are compared and contrasted.

  20. Concentrations of 99Tc and 137Cs in edible kelps and sea urchin ovaries from the northern part of Japan

    International Nuclear Information System (INIS)

    Ohtsuka, Y.; Iyogi, T.; Takaku, Y.; Hisamatsu, S.; Sekine, T.

    2006-01-01

    The first commercial nuclear fuel reprocessing plant in Japan is located in Rokkasho Village, Aomori Prefecture, and is now under the active test using actual spent nuclear fuels. Since the plant will release small amount of 99 Tc to the ocean, the concentration of 99 Tc in seawater nearby the plant will possibly increase in future. Since it is important to get background concentration levels of 99 Tc and 137 Cs in marine products from the ocean nearby the plant for assessing the effect to the concentration levels by the plant, the nuclides in edible kelps and sea urchin ovaries from the northern part of Japan (Aomori, Hokkaido and Iwate) were observed. Concentrations of 99 Tc in the kelps were lower than those reported for other non-edible seaweeds (Sargassum thunbergii) in Aomori, and the same level to the reported value of Hizikia fusiformis in Kyushu. 99 Tc concentrations in the urchin ovaries were lower than the detection limit of our method, and concentrations of 137 Cs in them were similar to these in the kelps. It suggested that 99 Tc is not concentrated in sea urchin ovaries. This work was supported by a grant from Aomori prefecture, Japan. (author)

  1. The development of 99mTc-analog of Cu-DTS as an agent for imaging hypoxia

    International Nuclear Information System (INIS)

    Horiuchi, K.; Tsukamoto, T.; Saito, M.; Nakayama, M.; Fujibayashi, Y.; Saji, H.

    2000-01-01

    Works on dithiosemicarbazone (DTS) derivatives radiolabeled with divalent Cu (Cu-62, Cu-64) indicate its potentiality as an ischemic tissue detecting agent. Development of analogous derivatives labeled with the more accessible technetium-99m (Tc) is most desirable. Various synthesized DTS derivatives are radiolabeled with a novel approach, using a macromolecular Sn(II)-complex under an anaerobic condition at pH 3.4-4.5 and stabilization by ascorbate solution at pH 6.7-7.0. Characterization of Tc-DTS derivatives done by various analytical methods (TLC, HPLC, EP, PC) and by in vivo studies in normal mice and in rats myocardial LAD (left anterior descent coronary artery) occlusion model. Among tested DTS, only Tc-ATSE, Tc-ATSM and Tc-ATSM 2 showed distinctive characteristics, with the latter presenting high myocardium uptake in regions of ischemia in LAD rat myocardium model. Potentiality of the Cu-DTS mimetic agent, Tc-ATSM 2 as an ischemia-damaged myocardium agent is discussed

  2. Preliminary studies of 99mTc-PQQ-NMDAR binding and effect of specificity binding by mannitol

    International Nuclear Information System (INIS)

    Xingqin Zhou; Yanyan Kong; Guoxian Cao; Jiankang Zhang

    2013-01-01

    Pyrroloquinoline quinone (PQQ) is a powerful neuroprotectant that specifically binds to brain NMDA receptors and inhibits excitotoxicity. Imaging this binding reaction in the brain remains a long sought goal in this field of study, and one of the primary challenges remaining is enabling soluble labeled PQQ to pass the blood-brain barrier (BBB). Previously, our group successfully labeled PQQ with Technetium-99m ( 99m Tc), a metastable nuclear isomer used in radioactive isotope medical tests. In this work, we determined the specific binding of 99m Tc-PQQ and NMDAR by radioligand receptor assay. Ebselen (EB) and MK-801 both effectively inhibited 99m Tc-PQQ binding. We then investigated methods of opening the BBB using mannitol to enable entry to the brain by 99m Tc-PQQ. Our results showed that 7.5 mL/kg of 20 % mannitol effectively opened the BBB and 20 min was the optimum treatment time. Competition studies showed that mannitol did not affect the specific binding between 99m Tc-PQQ and NMDA receptors. Using this method, the amount of 99m Tc-PQQ uptake and retention was increased most significantly in the hippocampus and cortex, and re-opening the BBB did not affect binding. Together, our results demonstrate that the use of mannitol to open the BBB may contribute significantly to improving image quality by increasing the uptake amount of a water-soluble agent in brain. (author)

  3. The Theobroma cacao B3 domain transcription factor TcLEC2 plays a duel role in control of embryo development and maturation.

    Science.gov (United States)

    Zhang, Yufan; Clemens, Adam; Maximova, Siela N; Guiltinan, Mark J

    2014-04-24

    The Arabidopsis thaliana LEC2 gene encodes a B3 domain transcription factor, which plays critical roles during both zygotic and somatic embryogenesis. LEC2 exerts significant impacts on determining embryogenic potential and various metabolic processes through a complicated genetic regulatory network. An ortholog of the Arabidopsis Leafy Cotyledon 2 gene (AtLEC2) was characterized in Theobroma cacao (TcLEC2). TcLEC2 encodes a B3 domain transcription factor preferentially expressed during early and late zygotic embryo development. The expression of TcLEC2 was higher in dedifferentiated cells competent for somatic embryogenesis (embryogenic calli), compared to non-embryogenic calli. Transient overexpression of TcLEC2 in immature zygotic embryos resulted in changes in gene expression profiles and fatty acid composition. Ectopic expression of TcLEC2 in cacao leaves changed the expression levels of several seed related genes. The overexpression of TcLEC2 in cacao explants greatly increased the frequency of regeneration of stably transformed somatic embryos. TcLEC2 overexpressing cotyledon explants exhibited a very high level of embryogenic competency and when cultured on hormone free medium, exhibited an iterative embryogenic chain-reaction. Our study revealed essential roles of TcLEC2 during both zygotic and somatic embryo development. Collectively, our evidence supports the conclusion that TcLEC2 is a functional ortholog of AtLEC2 and that it is involved in similar genetic regulatory networks during cacao somatic embryogenesis. To our knowledge, this is the first detailed report of the functional analysis of a LEC2 ortholog in a species other then Arabidopsis. TcLEC2 could potentially be used as a biomarker for the improvement of the SE process and screen for elite varieties in cacao germplasm.

  4. In vivo tumor angiogenesis imaging with site-specific labeled 99mTc-HYNIC-VEGF

    International Nuclear Information System (INIS)

    Blankenberg, Francis G.; Backer, Marina V.; Patel, Vimalkumar; Backer, Joseph M.; Levashova, Zoia

    2006-01-01

    We recently developed a cysteine-containing peptide tag (C-tag) that allows for site-specific modification of C-tag-containing fusion proteins with a bifunctional chelator, HYNIC (hydrazine nicotinamide)-maleimide. We then constructed and expressed C-tagged vascular endothelial growth factor (VEGF) and labeled it with HYNIC. We wished to test 99m Tc-HYNIC-C-tagged VEGF ( 99m Tc-HYNIC-VEGF) for the imaging of tumor vasculature before and after antiangiogenic (low continuous dosing, metronomic) and tumoricidal (high-dose) cyclophosphamide treatment. HYNIC-maleimide was reacted with the two thiol groups of C-tagged VEGF without any effect on biologic activity in vitro. 99m Tc-HYNIC-VEGF was prepared using tin/tricine as an exchange reagent, and injected via the tail vein (200-300 μCi, 1-2 μg protein) followed by microSPECT imaging 1 h later. Sequencing analysis of HYNIC-containing peptides obtained after digestion confirmed the site-specific labeling of the two accessible thiol groups of C-tagged VEGF. Tumor vascularity was easily visualized with 99m Tc/VEGF in Balb/c mice with 4T1 murine mammary carcinoma 10 days after implantation into the left axillary fat pad in controls (12.3±5.0 tumor/bkg, n=27) along with its decrease following treatment with high (150 mg/kg q.o.d. x 4; 1.14±0.48 tumor/bkg, n=9) or low (25 mg/kg q.d. x 7; 1.03±0.18 tumor/bkg, n=9) dose cyclophosphamide. Binding specificity was confirmed by observing a 75% decrease in tumor uptake of 99m Tc/biotin-inactivated VEGF, as compared with 99m Tc-HYNIC-VEGF. 99m Tc can be loaded onto C-tagged VEGF in a site-specific fashion without reducing its bioactivity. 99m Tc-HYNIC-VEGF can be rapidly prepared for the imaging of tumor vasculature and its response to different types of chemotherapy. (orig.)

  5. IMPLEMENTATION AND VALIDATION OF STATISTICAL TESTS IN RESEARCH'S SOFTWARE HELPING DATA COLLECTION AND PROTOCOLS ANALYSIS IN SURGERY.

    Science.gov (United States)

    Kuretzki, Carlos Henrique; Campos, Antônio Carlos Ligocki; Malafaia, Osvaldo; Soares, Sandramara Scandelari Kusano de Paula; Tenório, Sérgio Bernardo; Timi, Jorge Rufino Ribas

    2016-03-01

    The use of information technology is often applied in healthcare. With regard to scientific research, the SINPE(c) - Integrated Electronic Protocols was created as a tool to support researchers, offering clinical data standardization. By the time, SINPE(c) lacked statistical tests obtained by automatic analysis. Add to SINPE(c) features for automatic realization of the main statistical methods used in medicine . The study was divided into four topics: check the interest of users towards the implementation of the tests; search the frequency of their use in health care; carry out the implementation; and validate the results with researchers and their protocols. It was applied in a group of users of this software in their thesis in the strict sensu master and doctorate degrees in one postgraduate program in surgery. To assess the reliability of the statistics was compared the data obtained both automatically by SINPE(c) as manually held by a professional in statistics with experience with this type of study. There was concern for the use of automatic statistical tests, with good acceptance. The chi-square, Mann-Whitney, Fisher and t-Student were considered as tests frequently used by participants in medical studies. These methods have been implemented and thereafter approved as expected. The incorporation of the automatic SINPE (c) Statistical Analysis was shown to be reliable and equal to the manually done, validating its use as a research tool for medical research.

  6. 99mTc-HMPAO SPECT in brain death

    International Nuclear Information System (INIS)

    Tsuchida, Tatsuro; Sadato, Norihiro; Nishizawa, Sadahiko

    1993-01-01

    Brain single photon emission computed tomography (SPECT) with 99m Tc-d,l-hexamethyl-propyleneamine oxime (HMPAO) was performed twice in a 78-year-old man clinically diagnosed as brain death according to the standard criteria of the Japanese Ministry of Welfare. The first brain SPECT demonstrated the tracer accumulation in the brain, indicating preserved cerebral blood flow. The second brain SPECT performed 3 days later revealed cessation of the blood flow. In patients with preserved cerebral blood flow, the diagnosis of brain death cannot be made, even if they meet the existing criteria, because previous report noted the recovery in some of those patients. Brain perfusion SPECT plays an important role as a confirmatory test for the diagnosis of brain death. (author)

  7. 99mTc renal tubular function agents: Current status

    International Nuclear Information System (INIS)

    Eshima, D.; Fritzberg, A.R.; Taylor, A. Jr.

    1990-01-01

    Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3. 61 references

  8. Quality assurance of Mo-99/Tc-99m radionuclide generators

    Science.gov (United States)

    Uzunov, Nikolay; Yordanova, Galina; Salim, Seniha; Stancheva, Natalya; Mineva, Vanya; Meléndez-Alafort, Laura; Rosato, Antonio

    2018-03-01

    Gamma-ray spectrometry analyses of the radionuclide content of eluate from two Mo-99/Tc-99m radionuclide generators POLTECHNET have been performed. The relative activities of 99Mo 103Ru and 131I radioisotopes with respect to the activity of 99mTc at different time intervals after the primary pertechnetate elution of the generators have been analyzed. The relative activities of the isotopes were determined and compared to the radionuclidic purity requirements for 99mTc.

  9. To the radiotoxicity of {sup 99m}Tc radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Ftacnikova, S [Inst. of Preventive and Clinical Medicine, 83301 Bratislava (Slovakia)

    1996-12-31

    In this paper the radiotoxicity and RBE values of Auger electrons for {sup 99m}Tc radiopharmaceuticals were discussed. Expression for the expected RBE for {sup 99m}Tc compounds is given. For the Auger electrons emitted in the decay of {sup 99m}Tc the RBE(Auger) = 10 and a value of 20 for the radiation weighing factor were recommended. (J.K.) 4 refs.

  10. Preoperative localization of parathyroid carcinoma using Tc-99m MIBI.

    Science.gov (United States)

    Kitapçi, M T; Tastekin, G; Turgut, M; Caner, B; Kars, A; Barista, I; Bekdik, C

    1993-03-01

    A patient with parathyroid cancer is presented who underwent Tc-99m MIBI scintigraphy. The Tc-99m MIBI image demonstrated increased accumulation of activity at the lower pole of the left thyroid lobe which was later confirmed as a parathyroid cancer. Uptake by parathyroid cancer must be kept in mind as a cause of increased Tc-99m MIBI accumulation when a disease is in question in the thyroid or parathyroid gland.

  11. Jointscintigraphy with 99m Tc-pyrophosphate

    International Nuclear Information System (INIS)

    Mirtl, B.; Leb, G.; Klein, G.; Goebel, R.; Eber, O.

    1975-01-01

    Joint scintigraphy was performed in 85 patients suffering from a variety of rheumatic diseases, using a gamma camera and line scanner. Tc-pyrophosphate was the radio nuclide employed; it accumulates selectively in the juxta-articular parts of the bone. The method provides an objective demonstration of inflammatory and degenerative rheumatic joint changes. More over scintigraphic changes can be demonstrated in joint disease which is too early to be clinically apparent or before there are any corresponding changes in serological parameters. The method is useful both in the localisation and staging of disease, in the evaluation of treatment and as an objective control of clinical skills. (orig.) [de

  12. Post meningitis subdural hygroma: Anatomical and functional evaluation with 99mTc-ehylene cysteine dimer single photon emission tomography/computed tomography

    OpenAIRE

    Sharma, Punit; Mishra, Ajiv; Arora, Geetanjali; Tripathi, Madhavi; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Subdural hygroma is the collection of cerebrospinal fluid in the subdural space. Most often these resolve spontaneously. However, in cases with neurological complications surgical drainage may be needed. We here, present the case of an 8-year-old boy with post meningitis subdural hygroma. 99mTc-ehylene cysteine dimer (99mTc-ECD) hybrid single photon emission tomography/computed tomography (SPECT/CT) carried out in this patient, demonstrated the subdural hygroma as well as the associated cereb...

  13. Pressure and high-Tc superconductivity in sulfur hydrides.

    Science.gov (United States)

    Gor'kov, Lev P; Kresin, Vladimir Z

    2016-05-11

    The paper discusses fundamentals of record-TC superconductivity discovered under high pressure in sulfur hydride. The rapid increase of TC with pressure in the vicinity of Pcr ≈ 123GPa is interpreted as the fingerprint of a first-order structural transition. Based on the cubic symmetry of the high-TC phase, it is argued that the lower-TC phase has a different periodicity, possibly related to an instability with a commensurate structural vector. In addition to the acoustic branches, the phonon spectrum of H3S contains hydrogen modes with much higher frequencies. Because of the complex spectrum, usual methods of calculating TC are here inapplicable. A modified approach is formulated and shown to provide realistic values for TC and to determine the relative contributions of optical and acoustic branches. The isotope effect (change of TC upon Deuterium for Hydrogen substitution) originates from high frequency phonons and differs in the two phases. The decrease of TC following its maximum in the high-TC phase is a sign of intermixing with pairing at hole-like pockets which arise in the energy spectrum of the cubic phase at the structural transition. On-pockets pairing leads to the appearance of a second gap and is remarkable for its non-adiabatic regime: hydrogen mode frequencies are comparable to the Fermi energy.

  14. Achalasia diagnosed by 99mTc pertechnetate scintigraphy

    International Nuclear Information System (INIS)

    Mikosch, P.; Gallowitsch, H.J.; Kresnik, E.; Lind, P.

    1997-01-01

    A 73-year-old patient presented a 99m Tc scintiscan with a focal tracer accumulation left and caudal of the thyroid gland. Further investigations with sonography, CT, esophagoscopy and barium swallow provided the diagnosis of achalasia as the reason for focal 99m Tc retention caudal of the thyroid gland. Explanation for 99m Tc accumulation within the esophagus may be the nonspecific accumulation of 99m Tc not only in the thyroid gland but also in the salivary glands. Excretion of the tracer follows with the saliva. Structural and motor disorders of the esophagus can thus lead to focal tracer retention within the esophagus simulating thyroid tissue. (orig.) [de

  15. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  16. Chemistry of /sup 99m/Tc labeling kits

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Meinken, G.; Richards, P.

    1976-01-01

    Problems have been reported with the use of kit-produced /sup 99m/Tc radiopharmaceuticals. This study was undertaken to understand the chemistry involved in various stannous kit systems. The relation between Tc, tin, and the ligands used to complex the reduced Tc was investigated. It is concluded that for reliable performance, stannous kits should be prepared so that most of the tin is kept in the usable (reducing) form; a solution would be to use minimum tin and a large excess of complexing agent. Oxidation of the Tc complex to free pertechnetate is not a major problem in most kit systems. 5 figures

  17. Synthesis and comparison of 99mTc-enrofloxacin and 99mTc-ciprofloxacin.

    NARCIS (Netherlands)

    Siaens, R.H.; Rennen, H.J.J.M.; Boerman, O.C.; Dierckx, R.A.; Slegers, G.

    2004-01-01

    The use of (99m)Tc-ciprofloxacin as a tracer for infection and inflammation has been examined and discussed in the literature extensively. Its alleged ability to discriminate between sterile inflammation and bacterial versus nonbacterial infections has led to an intense debate. Other labeled

  18. Testing inter-observer reliability of the Transition Analysis aging method on the William M. Bass forensic skeletal collection.

    Science.gov (United States)

    Fojas, Christina L; Kim, Jieun; Minsky-Rowland, Jocelyn D; Algee-Hewitt, Bridget F B

    2018-01-01

    Skeletal age estimation is an integral part of the biological profile. Recent work shows how multiple-trait approaches better capture senescence as it occurs at different rates among individuals. Furthermore, a Bayesian statistical framework of analysis provides more useful age estimates. The component-scoring method of Transition Analysis (TA) may resolve many of the functional and statistical limitations of traditional phase-aging methods and is applicable to both paleodemography and forensic casework. The present study contributes to TA-research by validating TA for multiple, differently experienced observers using a collection of modern forensic skeletal cases. Five researchers independently applied TA to a random sample of 58 documented individuals from the William M. Bass Forensic Skeletal Collection, for whom knowledge of chronological age was withheld. Resulting scores were input into the ADBOU software and maximum likelihood estimates (MLEs) and 95% confidence intervals (CIs) were produced using the forensic prior. Krippendorff's alpha was used to evaluate interrater reliability and agreement. Inaccuracy and bias were measured to gauge the magnitude and direction of difference between estimated ages and chronological ages among the five observers. The majority of traits had moderate to excellent agreement among observers (≥0.6). The superior surface morphology had the least congruence (0.4), while the ventral symphyseal margin had the most (0.9) among scores. Inaccuracy was the lowest for individuals younger than 30 and the greatest for individuals over 60. Consistent over-estimation of individuals younger than 30 and under-estimation of individuals over 40 years old occurred. Individuals in their 30s showed a mixed pattern of under- and over-estimation among observers. These results support the use of the TA method by researchers of varying experience levels. Further, they validate its use on forensic cases, given the low error overall. © 2017 Wiley

  19. Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer.

    Science.gov (United States)

    O'Connor, Michael K; Morrow, Melissa M B; Hunt, Katie N; Boughey, Judy C; Wahner-Roedler, Dietlind L; Conners, Amy Lynn; Rhodes, Deborah J; Hruska, Carrie B

    2017-12-01

    Molecular breast imaging (MBI) performed with 99m Tc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99m Tc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99m Tc sestamibi and 99m Tc maraciclatide in patients with suspected breast cancer, using a high-resolution dedicated gamma camera for MBI. Women with breast lesions suspicious for malignancy were recruited to undergo two MBI examinations-one with 99m Tc sestamibi and one with 99m Tc maraciclatide. A radiologist interpreted MBI studies in a randomized, blinded fashion to assign an assessment score (1-5) and measured lesion size. Lesion-to-background (L/B) ratio was measured with region-of-interest analysis. Among 39 analyzable patients, 21 malignant tumors were identified in 21 patients. Eighteen of 21 tumors (86%) were seen on 99m Tc sestamibi MBI and 19 of 21 (90%) were seen on 99m Tc maraciclatide MBI (p = 1). Tumor extent measured with both radiopharmaceuticals correlated strongly with pathologic size ( 99m Tc sestamibi, r = 0.84; 99m Tc maraciclatide, r = 0.81). The L/B ratio in detected breast cancers was similar for the two radiopharmaceuticals: 1.55 ± 0.36 (mean ± S.D.) for 99m Tc sestamibi and 1.62 ± 0.37 (mean ± S.D.) for 99m Tc maraciclatide (p = 0.53). No correlation was found between the L/B ratio and molecular subtype for 99m Tc sestamibi (r s  = 0.12, p = 0.63) or 99m Tc maraciclatide (r s  = -0.12, p = 0.64). Of 20 benign lesions, 10 (50%) were seen on 99m Tc sestamibi and 9 of 20 (45%) were seen on 99m Tc maraciclatide images (p = 0.1). The average L/B ratio for benign lesions was 1.34 ±0.40 (mean ±S.D.) for 99m Tc sestamibi and 1.41 ±0.52 (mean ±S.D.) for 99m Tc maraciclatide (p = 0.75). Overall diagnostic performance was similar for both radiopharmaceuticals. AUC from ROC

  20. Mating tests among geographically separated collections of the Trametes versicolor (Fr.) Pilát (Basidiomycetes, Polyporales) group

    Czech Academy of Sciences Publication Activity Database

    Tomšovský, Michal; Homolka, Ladislav

    2004-01-01

    Roč. 79, 3-4 (2004), s. 425-431 ISSN 0029-5035 R&D Projects: GA ČR GA526/02/1216; GA ČR GD206/03/H137 Institutional research plan: CEZ:AV0Z5020903 Keywords : trametes versicolor * mating tests Subject RIV: EE - Microbiology, Virology Impact factor: 0.594, year: 2004

  1. [Measures to prevent patient identification errors in blood collection/physiological function testing utilizing a laboratory information system].

    Science.gov (United States)

    Shimazu, Chisato; Hoshino, Satoshi; Furukawa, Taiji

    2013-08-01

    We constructed an integrated personal identification workflow chart using both bar code reading and an all in-one laboratory information system. The information system not only handles test data but also the information needed for patient guidance in the laboratory department. The reception terminals at the entrance, displays for patient guidance and patient identification tools at blood-sampling booths are all controlled by the information system. The number of patient identification errors was greatly reduced by the system. However, identification errors have not been abolished in the ultrasound department. After re-evaluation of the patient identification process in this department, we recognized that the major reason for the errors came from excessive identification workflow. Ordinarily, an ultrasound test requires patient identification 3 times, because 3 different systems are required during the entire test process, i.e. ultrasound modality system, laboratory information system and a system for producing reports. We are trying to connect the 3 different systems to develop a one-time identification workflow, but it is not a simple task and has not been completed yet. Utilization of the laboratory information system is effective, but is not yet perfect for patient identification. The most fundamental procedure for patient identification is to ask a person's name even today. Everyday checks in the ordinary workflow and everyone's participation in safety-management activity are important for the prevention of patient identification errors.

  2. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    International Nuclear Information System (INIS)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-01-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function

  3. Collection and use of individual behavioral and consumption rate data to improve reconstruction of thyroid doses from nuclear weapons tests in Kazakhstan

    International Nuclear Information System (INIS)

    Drozdovitch, Vladimir; Schonfeld, Sara; Bouville, Andre; Land, Charles; Luckyanov, Nick; Simon, Steven L.; Schwerin, Michael

    2008-01-01

    Full text: Historical behavioral and consumption rate data were collected from residents of Kazakhstan exposed to nuclear weapons testing fallout using a focus group data collection strategy. These data will enable improved thyroid dose estimation in a radiation epidemiological study being carried out the U.S. National Cancer Institute. The study on the relationship of radiation exposure from weapons testing fallout and thyroid disease in a cohort of 2,994 subjects is now in a stage of improving earlier dose estimates based on individual information collected from a basic questionnaire administered to the study population in 1998. The study subjects of both Kazakh and Russian origin were exposed during childhood to radioactive fallout from nuclear weapons tests conducted at the Semipalatinsk Nuclear Test Site between 1949 and 1962. Due to the long time since exposure, a well developed strategy is necessary to encourage accurate memory recall. Limitations of the data collected in 1998 suggested the need to obtain reliable information that is tailored specific to the requirements of the dose reconstruction algorithm and to the evaluation of individual dose uncertainties. Focus group data collection in Kazakhstan in 2007 involved four 8-person focus groups (three of women and one of men) in each of four exposed settlements where thyroid disease screening was conducted in 1998. Age-specific data on relevant childhood behaviour, including time spent indoors and consumption of milk and other dairy products from cows, goats, horses, and sheep, were collected from women's groups. Men's focus groups were interviewed about construction materials of houses and schools as well as animal grazing patterns and supplemental feed to animals. Information obtained from the focus groups are being used to derive the settlement-, ethnicity-, age-, and gender-specific (where appropriate) probability density distributions on individual consumption rates of milk and dairy products

  4. Three-dimensional display of 99mTc-MIBI myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari

    1992-01-01

    One of 99m Tc-hexakis, 99m Tc-methoxyisobutyl isonitrile (MIBI), has been demonstrated to have a myocardial uptake proportional to regional coronary blood flow. In this study, 99m Tc-MIBI myocardial scintigraphy was performed for 16 patients with ischemic heart disease. After injection of 740 MBq of 99m Tc-MIBI, 64 projection images were collected during a 360-degree rotation. Three-dimensional (3D) display of the left ventricle was reconstructed with depth-shading method from 99m Tc-MIBI SPECT images, which were reconstructed by filtered back projection method. In 9 of the patients, left ventricular cineangiography were performed as diagnostic gold standard. Four physicians blinded to patients' clinical information interpreted 3D images and SPECT images on separate occasions. Diagnosis of hypoperfusion by 3D displays agreed with those of SPECT in 92.9% (104/112 segments), and disagreed in 7.1% (8 segments). Sensitivity and specificity of 3D images were 87.0% and 93.9%, which were not statistically different (p<0.05) from that of SPECT images (91.3%, 97.0%). Receiver operating characteristic (ROC) analysis revealed nearly identical curves for the two. Although 3D display had nearly identical diagnostic ability with SPECT, observers reported that 3D images were easier to diagnose than SPECT images. An advantage of the 3D display is that the display gives a more realistic impression of the left ventricle to an observer than tomography or planar imaging. Another advantage is that 3D display can reduce the amount of data storage compared with that of SPECT. In conclusion, 3D images may be useful for diagnosis of hypoperfusion of left ventricle. (author)

  5. Sup(99m)Tc-thioglucose

    International Nuclear Information System (INIS)

    Deckart, H.; Weiland, J.; Blottner, A.; Weiss, M.L.

    1978-01-01

    A procedure for labelling thioglucose with sup(99m)Tc with an efficiency of more than 95% yielding a compound with good in vitro and in vivo stability is presented. Pharmakokinetic studies in rats show slow blood-clearance and significant binding to plasma proteins and erythrocytes. Uptake in the kidneys was high and persistent. The whole body retention curve showed components with effective half-lives of 5 h (44,7%), 1,24 h (19,3%) and 7 min (36%). Autoradiography of kidney tissue reveal concentration of the compound in the epithelial cells of the tubulus of the cortex. No excretion via the liver was observed. The new compound was compared with other kidney scanning agents. Normal controls show in agreement with the animal experiments slow blood clearance and high as well as strong binding to plasma proteins. Whole-body retention combined with organ uptake studies show fast and persistent uptake in the kidneys so that the compound can be used for kidney imaging up to 24 h after application. Cumulative renal excretion is 18% of the dose during the first six hours. Finally, comparative studies of the differences in kidney imaging in normal patients and in patients with diseased kidneys using the new compound as well as conventional scanning agents ( 197 Hg neohydrine) and other sup(99m)Tc labelled compounds are presented. (author)

  6. Variation in NHS utilisation of vault smear tests in women post-hysterectomy: A study, using routinely collected datasets

    Directory of Open Access Journals (Sweden)

    Wilson Sue

    2008-03-01

    Full Text Available Abstract Background 20% of women living in the UK have a hysterectomy during their lifetime, levels are higher in the USA, making it one of the most commonly performed major surgical procedures. Understanding of the indications for hysterectomy and of the rationale for follow-up of women post hysterectomy is currently limited. Guidelines concerning follow-up by means of vaginal vault cytology tests exist but these are not based on 'gold standard' evidence. Furthermore, the extent to which current practice reflects these guidelines is unclear. This study aims to determine the factors associated with variability in hysterectomy rates and subsequent follow-up after surgery by use of the vaginal vault smear cytology test. Methods/Design All women resident in the West Midlands region, of the United Kingdom, who had a hysterectomy operation between 1st April 2002 and 30th March 2003 will be identified from the Hospital Episodes Statistics database which also contains proxy data on deprivation status, derived from postcode and self declared ethnicity. These data will be linked to regional cervical screening records for each woman and histopathology laboratory records from the relevant hospitals. Study objectives are to describe: Indications for the hysterectomy operation, histology at hysterectomy, subsequent follow-up by use or non-use of vaginal vault cytology tests and variation between histological groups. Additionally the data will be categorised according to a woman's cytology screening history prior to surgery (i.e. always normal, borderline, resolved abnormalities, CIN etc and these different groups compared. Variations in these outcomes according to age, deprivation and ethnic group will also be examined. Analysis will be undertaken using SPSS. Discussion This study will clarify patterns of current practice in one large English region and determine whether this practice reflects existing guidelines. The study will also strengthen the evidence

  7. Electrolytic 99mTcO4- reduction: a different pathway to obtain 99mTc-labelled compounds

    International Nuclear Information System (INIS)

    Savio, E.; Kremer, C.; Gambino, D.; Kremer, E.; Leon, A.

    1991-01-01

    Electrolytic reduction of 99m TcO 4 - at inert electrodes to obtain 99m Tc cationic complexes and in vitro stability of labelled compounds were studied. Amines were used as neutral N-donor ligands and a systematic analysis of various parameters involved in the reduction process was performed. Usefulness of electrolytic reduction was proved as an alternative 99m Tc-labelling method. Its most important advantages are: production of complexes with a high radiochemical purity, negligible presence of red-hyd- 99m Tc, lack of foreign materials, simplicity of development and possibility of further applications. (author)

  8. The role of Tc-99m IDA hepatobiliary and Tc-99m colloid hepatic imaging in primary biliary cirrhosis

    International Nuclear Information System (INIS)

    Aburano, T.; Yokoyama, K.; Shuke, N.; Kinuya, S.; Takayama, T.; Tonami, N.; Hisada, K.

    1991-01-01

    To assess the presence of primary biliary cirrhosis, 15 patients at various histopathologic stages were studied by Tc-99m IDA hepatobiliary and/or Tc-99m colloid hepatic imaging. In the earlier stages (I and II), seven of eight patients (88%) showed uniform hepatic retention of Tc-99m IDA. Of seven patients in the same stage, however, four (57%) showed no abnormality on Tc-99m colliod imaging. In three of these four negative patients (75%), uniform hepatic retention of Tc-99m IDA was noted. In the later stages (III and IV), all seven patients showed decreased clearance with or without delayed tracer appearance in the intestine and prominent hepatic retention on Tc-99m IDA imaging; with Tc-99m colloid imaging there was enlargement of the spleen and increased activity in the spleen and bone marrow. Thus, Tc-99m IDA imaging is considered to be more useful in revealing this functional disorder at the earlier stage of primary biliary cirrhosis and in evaluating progression from an earlier to a later stage of disease. Tc-99m colloid imaging also effectively evaluated progression

  9. Preoperative radiological diagnosis by 99mTc·MIBI-99mTc subtraction scintigraphy for primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Inouye, Takahiro; Tomita, Toshiki; Shinden, Seiichi; Takagi, Hitoshi; Kano, Shigeru.

    1996-01-01

    Preoperative radiological diagnosis constitutes the most important factor for the surgical treatment of hyperparathyroidism. In this regard, MRI is useful for detecting the abnormal parathyroid, but it is often difficult to localize it using MRI only. It is thus necessary to combine this procedure with excellent subtraction scintigraphy. We performed both 201 Tl- 99m Tc and 99m Tc·MIBI- 99m Tc subtraction scintigraphy in seven patients with primary hyperparathyroidism and compared them the radiological results. Five patients presented parathyroid adenomas and the rest hypertrophy of the parathyroid. We could detect the abnormal parathyroid in four patients (57.1%) by 201 Tl- 99m Tc subtraction scintigraphy and in six patients (85.7%) by 99m Tc·MIBI- 99m Tc subtraction scintigraphy. We therefore believe that 99m Tc·MIBI- 99m Tc subtraction scintigraphy will become an essential examination for primary hyperparathyroidism rather than the presently employed 201 Tl- 99m Tc subtraction scintigraphy. (author)

  10. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Predicting the sparticle spectrum from GUTs via SUSY threshold corrections with SusyTC

    Energy Technology Data Exchange (ETDEWEB)

    Antusch, Stefan [Department of Physics, University of Basel,Klingelbergstr. 82, CH-4056 Basel (Switzerland); Max-Planck-Institut für Physik (Werner-Heisenberg-Institut),Föhringer Ring 6, D-80805 München (Germany); Sluka, Constantin [Department of Physics, University of Basel,Klingelbergstr. 82, CH-4056 Basel (Switzerland)

    2016-07-21

    Grand Unified Theories (GUTs) can feature predictions for the ratios of quark and lepton Yukawa couplings at high energy, which can be tested with the increasingly precise results for the fermion masses, given at low energies. To perform such tests, the renormalization group (RG) running has to be performed with sufficient accuracy. In supersymmetric (SUSY) theories, the one-loop threshold corrections (TC) are of particular importance and, since they affect the quark-lepton mass relations, link a given GUT flavour model to the sparticle spectrum. To accurately study such predictions, we extend and generalize various formulas in the literature which are needed for a precision analysis of SUSY flavour GUT models. We introduce the new software tool SusyTC, a major extension to the Mathematica package REAP http://dx.doi.org/10.1088/1126-6708/2005/03/024, where these formulas are implemented. SusyTC extends the functionality of REAP by a full inclusion of the (complex) MSSM SUSY sector and a careful calculation of the one-loop SUSY threshold corrections for the full down-type quark, up-type quark and charged lepton Yukawa coupling matrices in the electroweak-unbroken phase. Among other useful features, SusyTC calculates the one-loop corrected pole mass of the charged (or the CP-odd) Higgs boson as well as provides output in SLHA conventions, i.e. the necessary input for external software, e.g. for performing a two-loop Higgs mass calculation. We apply SusyTC to study the predictions for the parameters of the CMSSM (mSUGRA) SUSY scenario from the set of GUT scale Yukawa relations ((y{sub e})/(y{sub d}))=−(1/2), ((y{sub μ})/(y{sub s}))=6, and ((y{sub τ})/(y{sub b}))=−(3/2), which has been proposed recently in the context of SUSY GUT flavour models.

  12. Proceedings of the international workshop on aged and decommissioned material collection and testing for structural integrity purposes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This workshop was sponsored by the CEC DG XI and XII/JRC Petten/AMES and by the Principal Working Group 3 (PWG-3) on reactor component integrity of the NEA CSNI, and it was hosted by the CEN Mol, Belgium. The activities of PWG-3 fall into three main areas: non-destructive examination (NDE), fracture analysis, and ageing/materials degradation. The topic of the workshop falls into the third area of ageing and materials degradation. The titles of the papers are: AMES and other European networks in Integrity of Ageing Structures; Over View of Proving Test on the Reliability of Material of Nuclear Power Plant Components; Activities on Ageing Degradation Phenomena of NPP in Korea; Capability of Investigation on Decommissioned Parts from NPPs at the MPA Stuttgart; How Accurately can Surveillance Specimens Reflect the True State of RPV Materials?; Applicability of Design Codes to Aged Materials; Microstructural Investigations of as-Fabricated, Long-Term Thermally Aged and Neutron Irradiated RPV Materials: An Atom Probe Study; Proposed Post-Service Investigations on Decommissioned Greifswald Units; Tools and Experience in Post Irradiation Examination of Structural Core Components at PSI Hot laboratory; Testing of Beznau NPP Unit 1 Steam Generator Cast Stainless Steel Elbows; Mechanical Properties Characterisation of Irradiated Materials From Operating or Decommissioned Nuclear Power Plants; Long Term Ageing of Cast Ti-Stabilised Stainless Steel; Enhanced Surveillance of Nuclear Reactor Pressure Vessels. Discussions and conclusions are also presented

  13. Land Surface Reflectance Retrieval from Hyperspectral Data Collected by an Unmanned Aerial Vehicle over the Baotou Test Site

    Science.gov (United States)

    Duan, Si-Bo; Li, Zhao-Liang; Tang, Bo-Hui; Wu, Hua; Ma, Lingling; Zhao, Enyu; Li, Chuanrong

    2013-01-01

    To evaluate the in-flight performance of a new hyperspectral sensor onboard an unmanned aerial vehicle (UAV-HYPER), a comprehensive field campaign was conducted over the Baotou test site in China on 3 September 2011. Several portable reference reflectance targets were deployed across the test site. The radiometric performance of the UAV-HYPER sensor was assessed in terms of signal-to-noise ratio (SNR) and the calibration accuracy. The SNR of the different bands of the UAV-HYPER sensor was estimated to be between approximately 5 and 120 over the homogeneous targets, and the linear response of the apparent reflectance ranged from approximately 0.05 to 0.45. The uniform and non-uniform Lambertian land surface reflectance was retrieved and validated using in situ measurements, with root mean square error (RMSE) of approximately 0.01–0.07 and relative RMSE of approximately 5%–12%. There were small discrepancies between the retrieved uniform and non-uniform Lambertian land surface reflectance over the homogeneous targets and under low aerosol optical depth (AOD) conditions (AOD = 0.18). However, these discrepancies must be taken into account when adjacent pixels had large land surface reflectance contrast and under high AOD conditions (e.g. AOD = 1.0). PMID:23785513

  14. sup(99m)Tc-PI as safe and easy scintigraphy after hepatectomy

    International Nuclear Information System (INIS)

    Terui, Shoji; Oyamada, Hiyoshimaru; Hasegawa, Hiroshi

    1980-01-01

    Hepatobiliary scintigraphy with sup(99m)Tc-PI was performed on 16 patients after various types of hepatectomy for either primary or secondary liver tumor. sup(99m)Tc-PI scintigraphy was found very useful, especially in regard to clinical evaluation of indistinct low-uptake areas observed on a sup(99m)Tc colloid liver scintigram in the regenerating liver after hepatectomy. Both tests were conducted successively within a couple of weeks. Colloid scintigrams after hepatectomy were divided into two groups according to the sites of indistinct low-uptake areas; one showed them near the resected margin of the regenerating liver (Type I), and the other showed them in both marginal and intrahepatic regions (Type II). Of these 16 patients, 8 showed Type I and 7 showed Type II. The remaining one was excluded for postsurgical complications. By comparing the colloid scintigram with the sup(99m)Tc-PI scintigram, in all the cases of Type I indistinct low-uptake areas were found to be the hilum with a shifted common bile duct. On the other hand, in 2 cases of Type II indistinct low-uptake areas were caused by the hilum accompanied by the dilated bile ducts. In the remaining 5, indistinct low-uptake areas were not identified as bile ducts but were confirmed to be a recurrence of the tumor. (author)

  15. Studies of labelling conditions for gentamicin with99mTc Biological uptake

    International Nuclear Information System (INIS)

    Carvalho, O.G. de; Almeida, M.A.T.M. de; Muramoto, E.

    1989-10-01

    Gentamicin sulphate is an aminoglycoside antibiotic type specifically used for treatment of infections produced by Gram-negative bacterias but on the hand it presents ototoxic reactions as a serious side effect. The optimal labelling conditions of gentamicin sulphate with 99m Tc, using sodium pertechnetate solutions eluted from a 99 Mo - 99m Tc generator, were stablished by testing differents masses of antibiotic and reducing agent (SnCl 2 .2H 2 O), and also different reaction times and final labelling pH. The labelling yields were determined through ascendent type crimatographic analysis using metylacetone and 0,9% NaCl solution as solvents. From the studies of the biological uptake of 99m Tc gentamicin sulphate per gram of eight different organs and tissues from Wistar rats, it was shown that for a dose of 0,3 mg of 99m Tc-gentamicin intravenously administered. The kidneys, presented the greatest affinity for the drug, being thus the main excretory organs of the product. (author) [pt

  16. Solubility study of Tc(IV) in a granitic water

    International Nuclear Information System (INIS)

    Liu, D.J.; Yao, J.; Wang, B.; Bruggeman, C.; Maes, N.

    2007-01-01

    The deep geological disposal of the high level radioactive wastes is expected to be a safe disposal method in most countries. The long-lived fission product 99 Tc is present in large quantities in nuclear wastes and its chemical behavior in aqueous solution is of considerable interest. Under oxidizing conditions technetium exists as the anionic species TcO 4 - whereas under the reducing conditions, expected to exist in a deep geological repository, it is generally predicted that technetium will be present as TcO 2 .nH 2 O. Hence, the mobility of Tc(IV) in reducing groundwater may be limited by the solubility of TcO 2 .nH 2 O under these conditions. Due to this fact it is important to investigate the solubility of TcO 2 .nH 2 O. The solubility determines the release of radionuclides from waste form and is used as a source term in radionuclide migration analysis in performance assessment of radioactive waste repository. Technetium(IV) was prepared by reduction of a technetate solution with Sn 2+ . The solubility of Tc(IV) has been determined in simulated groundwater and redistilled water under aerobic and anaerobic conditions. The effects of pH and CO 3 2- concentration of solution on solubility of Tc(IV) were studied. The concentration of total technetium and Tc(IV) species in the solutions were periodically determined by separating the oxidized and reduced technetium species using a solvent extraction procedure and counting the beta activity of the 99 Tc with a liquid scintillation counter. The experimental results show that the rate of oxidation of Tc(IV) in simulated groundwater and redistilled water is about (1.49 ∝ 1.86) x 10 -9 mol L -1 d -1 under aerobic conditions, while no Tc(IV) oxidation was detected in simulated groundwater and redistilled water under anaerobic conditions. Under aerobic or anaerobic conditions the solubility of Tc(IV) in simulated groundwater and redistilled water is equal on the whole after centrifugation or ultrafiltration. The

  17. Determination of 99Mo in 99mTc eluates used in nuclear medicine centers in Rio de Janeiro

    International Nuclear Information System (INIS)

    Ribeiro, Bianca da S.; Souza, Raphael S.S.; Lucena, Eder A.; Dantas, Ana Leticia A.; Dantas, Bernardo M.

    2009-01-01

    99m Tc is used in nuclear medicine for image diagnoses with SPECT. It is obtained from the elution of molybdenum-99/technetium-99m ( 99 Mo/ 99m Tc) generators. During the elution, 99 Mo can detach from the column, passing through the filter and mixing in the solution of pertechnetate eluate and becoming a radionuclidic impurity. The presence of molybdenum in the radiopharmaceutical solution imparts an unnecessary radiation dose to the patient, since its half-life is relatively long (66 hours) and it emits beta particles and high-energy photons of (740 keV). A parameter that indicates the quality of the eluates is the radionuclidic purity, the MBT (molybdenum break through), defined as the ratio between 99 Mo and 99m Tc activities in the eluate. The American and the European Pharmacopoeias restrict 99 Mo content to respectively 0.015% and 0.1% activity ratio 99 Mo/ 99m Tc at the time of the administration to the patient. In Brazil, this parameter is not controlled by official regulations. The objective of this work is to determine the presence of 99 Mo in the eluates used in nuclear medicine centers (NMC). The activity measurements of 99 Mo were performed with a NaI(Tl)8''x4'' scintillation detector installed in the IRD whole body counter. The activity of 99m Tc was measured in the NMC where the eluates were collected and, using the established calculations, it was determined the activity ratio 99 Mo/ 99m Tc. The eluate samples were kindly supplied by the participating NMC of Rio de Janeiro. All measurements indicated the presence of 99 Mo. It is concluded that the technique is sensitive to detect 99 Mo in 99m Tc eluates and permits to verify the quality of the generators used in NMC evaluated in this study. (author)

  18. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo

    International Nuclear Information System (INIS)

    Bernard, Bert F.; Krenning, Eric P.; Breeman, Wout A. P.; Ensing, Geert; Benjamins, Harry; Bakker, Willem H.; Visser, Theo J.; Jong, Marion de

    1998-01-01

    The aim of this study was to compare uptake of 99m Tc-MIBI, 99m Tc-tetrofosmin and 99m Tc-Q12 in vitro and biodistribution in vivo in rats. In vitro, uptake decreased in the order MIBI→tetrofosmin→Q12. Uptake of MIBI and tetrofosmin, but not of Q12, in cultured tumor cells was dependent on the plasma membrane and mitochondrial potential. In vivo, heart uptake of all three compounds was high and stable. Tumor uptake decreased in the order MIBI→Q12→tetrofosmin and the tumor/blood ratio in the order MIBI→tetrofosmin→Q12

  19. Web-Based Survey Application to Collect Contextually Relevant Geographic Data With Exposure Times: Application Development and Feasibility Testing

    Science.gov (United States)

    Tobin, Karin; Rudolph, Jonathan; Latkin, Carl

    2018-01-01

    Background Although studies that characterize the risk environment by linking contextual factors with individual-level data have advanced infectious disease and substance use research, there are opportunities to refine how we define relevant neighborhood exposures; this can in turn reduce the potential for exposure misclassification. For example, for those who do not inject at home, injection risk behaviors may be more influenced by the environment where they inject than where they live. Similarly, among those who spend more time away from home, a measure that accounts for different neighborhood exposures by weighting each unique location proportional to the percentage of time spent there may be more correlated with health behaviors than one’s residential environment. Objective This study aimed to develop a Web-based application that interacts with Google Maps application program interfaces (APIs) to collect contextually relevant locations and the amount of time spent in each. Our analysis examined the extent of overlap across different location types and compared different approaches for classifying neighborhood exposure. Methods Between May 2014 and March 2017, 547 participants enrolled in a Baltimore HIV care and prevention study completed an interviewer-administered Web-based survey that collected information about where participants were recruited, worked, lived, socialized, injected drugs, and spent most of their time. For each location, participants gave an address or intersection which they confirmed using Google Map and Street views. Geographic coordinates (and hours spent in each location) were joined to neighborhood indicators by Community Statistical Area (CSA). We computed a weighted exposure based on the proportion of time spent in each unique location. We compared neighborhood exposures based on each of the different location types with one another and the weighted exposure using analysis of variance with Bonferroni corrections to account for

  20. Knowledge and attitudes of pregnant women with regard to collection, testing and banking of cord blood stem cells.

    Science.gov (United States)

    Fernandez, Conrad V; Gordon, Kevin; Van den Hof, Michiel; Taweel, Shaureen; Baylis, Françoise

    2003-03-18

    Umbilical cord blood is used as a source of hematopoietic stem cells for bone marrow transplantation in the treatment of malignant and nonmalignant disease. We sought to examine pregnant women's knowledge and attitudes regarding cord blood banking, as their support is crucial to the success of cord blood transplant programs. A questionnaire examining sociodemographic factors and women's attitudes to cord blood banking was developed on the basis of findings from 2 focus groups and a pilot study. The questionnaire was distributed to 650 women attending antenatal clinics at a regional women's hospital between April and July 2001. A total of 443 women (68%) responded. More than half of the women (307/438 or 70% [95% confidence interval, CI, 66% to 74%]) reported poor or very poor knowledge about cord blood banking. Many of the respondents (299/441 or 68% [95% CI 63% to 72%]) thought that physicians should talk to pregnant women about the collection of cord blood, and they wanted to receive information about this topic from health care professionals (290/441 or 66% [95% CI 61% to 70%]) or prenatal classes (308/441 or 70% [95% CI 65% to 74%]). Most of the women (379/442 or 86% [95% CI 82% to 89%]) would elect to store cord blood in a public bank, many citing altruism as the reason for this choice. A much smaller proportion (63/442 or 14% [95% CI 11% to 18%]) would elect private banking, indicating that this would be a good investment or that they would feel guilty if the blood had not been stored. Additional acceptable uses for cord blood included research (mentioned by 294/436 women or 67% [95% CI 63% to 72%]) and gene therapy (mentioned by 169/437 women or 39% [95% CI 34% to 43%]). Most of the women in this study supported the donation of cord blood to public cord blood banks for potential transplantation and research.

  1. Three-dimensional vs. two-dimensional shear-wave elastography of the testes - preliminary study on a healthy collective.

    Science.gov (United States)

    Marcon, J; Trottmann, M; Rübenthaler, J; D'Anastasi, M; Stief, C G; Reiser, M F; Clevert, D A

    2016-01-01

    Shear wave elastography (SWE) and its derivative Supersonic Shear Imaging (SSI) are newer techniques for the determination of tissue elasticity by measuring the velocity of generated shear waves (SWV), which correlates positively with tissue stiffness.The techniques are integrated into many modern ultrasound systems and have been examined in the evaluation of viscoelastic properties of different organ systems. Two-dimensional shear wave elastography (2D SWE) of the testes has been found to be a useful tool in recent studies which included the determination of standard values in healthy volunteers. Three-dimensional shear wave elastography (3D SWE) is the latest development in elastography and is made possible by generation of a multiplanar three-dimensional map via volumetric acquisition with a special ultrasound transducer. This technique allows the assessment of tissue elasticity in a three-dimensional, fully accessible organ map.The aim of this preliminary study was to both evaluate the feasibility of 3D SWE and to compare 2D and 3D SWE standard values in the testes of healthy subjects. We examined the testes of healthy male volunteers (n = 32) with a mean age of 51.06±17.75 years (range 25-77 years) by B-mode ultrasound, 2D and 3D SWE techniques in September of 2016. Volunteers with a history of testicular pathologies were excluded. For all imaging procedures the SL15-4 linear transducer (bandwidth 4-15 MHz) as well as the SLV16-4 volumetric probe (bandwidth 4-16 MHz) of the Aixplorer® ultrasound device (SuperSonic Imagine, Aix-en-Provence, France) were used. Seven regions of interest (ROI, Q-Box®) within the testes were evaluated for SWV using both procedures. SWV values were described in m/s. Results were statistically evaluated using univariateanalysis. Mean SWV values were 1.05 m/s for the 2D SWE and 1.12 m/s for the 3D SWE.Comparisons of local areas delivered no statistically significant differences (p = 0.11 to p = 0.66), except for

  2. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  3. {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Wolfgang M.; Moka, Detlef E-mail: detlef.moka@uni-koeln.de; Brockmann, Holger A.; Schomaecker, Klaus; Schicha, Harald

    2002-02-01

    Myocellular kinetics of {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order {sup 99m}Tc-MIBI {yields}{yields} implies {sup 99m}Tc-tetrofosmin {yields}{yields} implies {sup 99m}Tc-furifosmin. {sup 201}Tl and {sup 99m}Tc-MIBI exhibited bi- (t1,t2), {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from {sup 201}Tl (t2) {yields}{yields} implies {sup 99m}Tc-MIBI (t2) {yields}{yields} implies {sup 99m}Tc-tetrofosmin (t3) {yields}{yields} implies {sup 99m}Tc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but {sup 99m}Tc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of {sup 201}Tl, and suggests a similar phenomenon for {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin.

  4. Instrumented Pressure Testing Chamber (IPTC) Characterization of Methane Gas Hydrate-Bearing Pressure Cores Collected from the Methane Production Test Site in the Eastern Nankai Trough, Offshore Japan

    Science.gov (United States)

    Waite, W. F.; Santamarina, J. C.; Dai, S.; Winters, W. J.; Yoneda, J.; Konno, Y.; Nagao, J.; Suzuki, K.; Fujii, T.; Mason, D. H.; Bergeron, E.

    2014-12-01

    Pressure cores obtained at the Daini-Atsumi Knoll in the eastern Nankai Trough, the site of the methane hydrate production test completed by the Methane Hydrate Resources in Japan (MH21) project in March 2013, were recovered from ~300 meters beneath the sea floor at close to in situ pressure. Cores were subsequently stored at ~20 MPa and ~5°C, which maintained hydrate in the cores within stability conditions. Pressure core physical properties were measured at 10 MPa and ~6°C, also within the methane hydrate stability field, using the IPTC and other Pressure Core Characterization Tools (PCCTs). Discrete IPTC measurements were carried out in strata ranging from silty sands to clayey silts within the turbidite sequences recovered in the cores. As expected, hydrate saturations were greatest in more permeable coarser-grained layers. Key results include: 1) Where hydrate saturation exceeded 40% in sandy sediments, the gas hydrate binds sediment grains within the matrix. The pressure core analyses yielded nearly in situ mechanical properties despite the absence of effective stress in the IPTC. 2) In adjacent fine-grained sediment (hydrate saturation < 15%), hydrate did not significantly bind the sediment. IPTC results in these locations were consistent with the zero effective-stress limit of comparable measurements made in PCCT devices that are designed to restore the specimen's in situ effective stress. In sand-rich intervals with high gas hydrate saturations, the measured compressional and shear wave velocities suggest that hydrate acts as a homogeneously-distributed, load-bearing member of the bulk sediment. The sands with high gas hydrate saturations were prone to fracturing (brittle failure) during insertion of the cone penetrometer and electrical conductivity probes. Authors would like to express their sincere appreciation to MH21 and the Ministry of Economy, Trade and Industry for permitting this work to be disclosed at the 2014 Fall AGU meeting.

  5. Evaluation of the absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) and Tc{sup 99m} (Dmsa); Evaluacion de la dosis absorbida en los rinones debido al Tc{sup 99m} (DTPA) / Tc{sup 99m} (MAG3) y Tc{sup 99m} (DMSA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Idrogo C, J.; Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) or Tc{sup 99m} (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3), are given by 0.00466 mGy.MBq{sup -1} / 0.00339 mGy.MBq{sup -1}. Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3). The absorbed dose to the kidneys due to Tc{sup 99m} (Dmsa) is 0.17881 mGy.MBq{sup -1}. Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc{sup 99m} (Dmsa). (Author)

  6. Radiological results for samples collected on paired glass- and cellulose-fiber filters at the Sandia complex, Tonopah Test Range, Nevada

    International Nuclear Information System (INIS)

    Mizell, Steve A.; Shadel, Craig A.

    2016-01-01

    Airborne particulates are collected at U.S. Department of Energy sites that exhibit radiological contamination on the soil surface to help assess the potential for wind to transport radionuclides from the contamination sites. Collecting these samples was originally accomplished by drawing air through a cellulose-fiber filter. These filters were replaced with glass-fiber filters in March 2011. Airborne particulates were collected side by side on the two filter materials between May 2013 and May 2014. Comparisons of the sample mass and the radioactivity determinations for the side-by-side samples were undertaken to determine if the change in the filter medium produced significant results. The differences in the results obtained using the two filter types were assessed visually by evaluating the time series and correlation plots and statistically by conducting a nonparametric matched-pair sign test. Generally, the glass-fiber filters collect larger samples of particulates and produce higher radioactivity values for the gross alpha, gross beta, and gamma spectroscopy analyses. However, the correlation between the radioanalytical results for the glass-fiber filters and the cellulose-fiber filters was not strong enough to generate a linear regression function to estimate the