WorldWideScience

Sample records for test chambers

  1. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  2. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    1999-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  3. Refrigeration Test Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The enclosed and environmentally controlled chamber is able to test four units (single-phase) simultaneously at conditions ranging from tundra to desert temperatures...

  4. Anechoic Radio Frequency Test Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — This chamber is used for characterization test of such systems as communications gear, tanks, radar, missiles, and helicopters. The dimensions of the chamber are 114...

  5. AC Test Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Psychrometric Test Chamber’s primary purpose is to evaluate the performance of split type central air conditioners and heat pumps in the cooling capacity range...

  6. Testing an hydrogen streamer chamber

    CERN Multimedia

    1975-01-01

    A 2x10 cm gap streamer chamber, 35x55 cm2 in surface, was built and tested at CERN. Good tracks of cosmic rays were obtained up to atmospheric pressure, see F. Rohrbach et al, CERN-LAL (Orsay) Collaboration, Nucl. Instr. Methods 141 (1977) 229. Michel Cathenoz stand on the center.

  7. Chamber B Thermal/Vacuum Chamber: User Test Planning Guide

    Science.gov (United States)

    Montz, Mike E.

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of Chamber B. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  8. Tests of anechoic chamber for aeroacoustics investigations

    Science.gov (United States)

    Palchikovskiy, V. V.; Bersenev, Yu. V.; Makashov, S. Yu.; Belyaev, I. V.; Korin, I. A.; Sorokin, E. V.; Khramtsov, I. V.; Kustov, O. Yu.

    2016-10-01

    The paper presents the results of qualification tests in the new anechoic chamber of Perm National Research Polytechnic University (PNRPU) built in 2014-2015 and evaluation of the chamber quality in aeroacoustic experiments. It describes design features of the chamber and its sound-absorption lining. The qualification tests were carried out with tonal and broadband noise sources in the frequency range 100 Hz - 20 kHz for two different cases of the source arrangement. In every case, measurements were performed in three directions by traverse microphones. Qualification tests have determined that in the chamber there is a free acoustic field within radius of 2 m for tonal noise and 3 m for broadband noise. There was also evaluated acoustic quality of the chamber by measurements of the jet noise and vortex ring noise. The results of the experiments demonstrate that PNRPU anechoic chamber allows the aeroacoustic measurements to be performed to obtain quantitative results.

  9. Reproducibility of the chamber scarification test

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner

    1996-01-01

    The chamber scarification test is a predictive human skin irritation test developed to rank the irritation potential of products and ingredients meant for repeated use on normal and diseased skin. 12 products or ingredients can be tested simultaneously on the forearm skin of each volunteer. The t...

  10. Almond Test Body. [for microwave anechoic chambers

    Science.gov (United States)

    Dominek, Allen K. (Inventor); Wood, Richard M. (Inventor); Gilreath, Melvin C. (Inventor)

    1989-01-01

    The invention is an almond shaped test body for use in measuring the performance characteristics of microwave anechoic chambers and for use as a support for components undergoing radar cross-section measurements. The novel aspect of this invention is its shape, which produces a large dynamic scattered field over large angular regions making the almond valuable for verifying the performance of microwave anechoic chambers. As a component mount, the almond exhibits a low return that does not perturb the measurement of the component and it simulates the backscatter characteristics of the component as if over an infinite ground plane.

  11. Almond test body. [for microwave anechoic chambers

    Science.gov (United States)

    Dominek, Allen K. (Inventor); Wood, Richard M. (Inventor); Gilreath, Melvin C. (Inventor)

    1989-01-01

    The invention is an almond shaped test body for use in measuring the performance characteristics of microwave anechoic chambers and for use as a support for components undergoing radar cross-section measurements. The novel aspect of this invention is its shape, which produces a large dynamic scattered field over large angular regions making the almond valuable for verifying the performance of microwave anechoic chambers. As a component mount, the almond exhibits a low return that does not perturb the measurement of the component and it simulates the backscatter characteristics of the component as if over an infinite ground plane.

  12. Testing fireproof materials in a combustion chamber

    Directory of Open Access Journals (Sweden)

    Kulhavy Petr

    2017-01-01

    Full Text Available This article deals with a prototype concept, real experiment and numerical simulation of a combustion chamber, designed for testing fire resistance some new insulating composite materials. This concept of a device used for testing various materials, providing possibility of monitoring temperatures during controlled gas combustion. As a fuel for the combustion process propane butane mixture has been used and also several kinds of burners with various conditions of inlet air (forced, free and fuel flows were tested. The tested samples were layered sandwich materials based on various materials or foams, used as fillers in fire shutters. The temperature distribution was measured by using thermocouples. A simulation of whole concept of experimental chamber has been carried out as the non-premixed combustion process in the commercial final volume sw Pyrosim. The result was to design chamber with a construction suitable, according to the international standards, achieve the required values (temperature in time. Model of the combustion based on a stoichiometric defined mixture of gas and the tested layered samples showed good conformity with experimental results – i.e. thermal distribution inside and heat release rate that has gone through the sample.

  13. Testing fireproof materials in a combustion chamber

    Science.gov (United States)

    Kulhavy, Petr; Martinec, Tomas; Novak, Ondrej; Petru, Michal; Srb, Pavel

    This article deals with a prototype concept, real experiment and numerical simulation of a combustion chamber, designed for testing fire resistance some new insulating composite materials. This concept of a device used for testing various materials, providing possibility of monitoring temperatures during controlled gas combustion. As a fuel for the combustion process propane butane mixture has been used and also several kinds of burners with various conditions of inlet air (forced, free) and fuel flows were tested. The tested samples were layered sandwich materials based on various materials or foams, used as fillers in fire shutters. The temperature distribution was measured by using thermocouples. A simulation of whole concept of experimental chamber has been carried out as the non-premixed combustion process in the commercial final volume sw Pyrosim. The result was to design chamber with a construction suitable, according to the international standards, achieve the required values (temperature in time). Model of the combustion based on a stoichiometric defined mixture of gas and the tested layered samples showed good conformity with experimental results - i.e. thermal distribution inside and heat release rate that has gone through the sample.

  14. GBO RF Anechoic Chamber & Antenna Test Range

    Data.gov (United States)

    Federal Laboratory Consortium — A shielded anechoic chamber measuring 15 by 15 by 37 feet is located in the Jansky Laboratory at Green Bank. This chamber has been outfitted as a far-field antenna...

  15. Test of an undulated vacuum chamber for the ISR

    CERN Multimedia

    1975-01-01

    This picture shows mechanical tests of an undulated vacuum chamber for downstream arms of ISR intersections. This chamber, made of 0.3 mm thick inconel, had inner dimensions of 150 mm by 50 mm. The deflection under vacuum is measured by dial gauges. On the left one sees the large vessel where vacuum chambers were tested at pressures above atmospheric pressure.

  16. Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2015-01-01

    The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.

  17. NASA Teams With Army in Vortex Combustion Chamber Engine Test

    Science.gov (United States)

    2003-01-01

    This photograph depicts one of over thirty tests conducted on the Vortex Combustion Chamber Engine at Marshall Space Flight Center's (MSFC) test stand 115, a joint effort between NASA's MSFC and the U.S. Army AMCOM of Redstone Arsenal. The engine tests were conducted to evaluate an irnovative, 'self-cooled', vortex combustion chamber, which relies on tangentially injected propellants from the chamber wall producing centrifugal forces that keep the relatively cold liquid propellants near the wall.

  18. MAN-IN-SIMULANT TEST (MIST) CHAMBER

    Data.gov (United States)

    Federal Laboratory Consortium — The MIST chamber uses methyl salicylate (oil of wintergreen) vapor as a simulant for HD agent to conduct system level evaluations of chemical protective ensembles....

  19. Production and test of the LHCb Muon Chamber

    CERN Multimedia

    2005-01-01

    - The Muon System of LHCb - The Multi-Wire Proportional Chambers for LHCb - Wire tension meter - Wire pitch measurement - Gas leakage test - Test with cosmic rays - Production and test summary - Gap gain uniformity - Production and test summary

  20. Lifetime tests for MAC vertex chamber

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, H.N.

    1986-07-01

    A vertex chamber for MAC was proposed to increase precision in the measurement of the B hadron and tau lepton lifetimes. Thin-walled aluminized mylar drift tubes were used for detector elements. A study of radiation hardness was conducted under the conditions of the proposed design using different gases and different operating conditions. (LEW)

  1. Ageing tests for the MEG II drift chamber

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, M., E-mail: marco.venturini@pi.infn.it [Scuola Normale Superiore, Piazza dei Cavalieri 7, 56126 Pisa (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Baldini, A.M. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Baracchini, E. [ICEPP, University of Tokyo 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Cei, F.; D' Onofrio, A. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Dipartimento di Fisica, Universita di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Dussoni, S.; Galli, L.; Grassi, M. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Nicolò, D. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Dipartimento di Fisica, Universita di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Signorelli, G.; Tenchini, F. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Zermini, A. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Dipartimento di Fisica, Universita di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy)

    2016-07-11

    The MEG II drift chamber will track positrons from μ{sup +} decays in a very harsh environment. For testing the robustness of the chamber to ageing effects an irradiation facility was set up at INFN Pisa. - Highlights: • We built up an X-ray facility for ageing studies of particle detectors. • Stable irradiation conditions were obtained over one-month timescale. • A moderate gain loss is expected for the MEG II drift chamber.

  2. Design of a Hyperbaric Chamber for Pressure Testing

    Directory of Open Access Journals (Sweden)

    Mohamad Sazali Shahmir Fikhri bin

    2014-07-01

    Full Text Available A hyperbaric chamber is an application of a pressure vessel to test the integrity of components and equipments subjected to high pressure. The chamber comprises of several main parts such as a shell, heads, instrumentation attachments, threaded fasteners and support. This paper describes the design of hyperbaric chamber for pressure testing that compiles to the ASME Boiler and Pressure Vessel code. The design approach adopted is the “design by formula” method. A structural analysis of the hyperbaric chamber with a cylindrical shell and a vertical orientation, based on an operating pressure of 34.5 MPa, was done. The analysis of the stress distribution shows that the normalized principal stresses acting on the chamber are within the yield envelop based on the maximum distortional energy criteria.

  3. Imploded test-chamber for an ISR intersection

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    At the ISR intersection points the vacuum chambers had to be as "transparent" as possible, for the p-p collision product particles to reach the detectors with minimum hindrance. This meant the choice of a light, yet very strong, metal; minimum thickness; and corrugation for mechanical strength. The test-chamber seen here was made of 0.6 mm thick corrugated titanium, obviously not strong enough to withstand the atmospheric pressure.

  4. Autoignition Chamber for Remote Testing of Pyrotechnic Devices

    Science.gov (United States)

    Harrington, Maureen L.; Steward, Gerald R.; Dartez, Toby W.

    2009-01-01

    The autoignition chamber (AIC) performs by remotely heating pyrotechnic devices that can fit the inner diameter of the tube furnace. Two methods, a cold start or a hot start, can be used with this device in autoignition testing of pyrotechnics. A cold start means extending a pyrotechnic device into the cold autoignition chamber and then heating the device until autoignition occurs. A hot start means heating the autoignition chamber to a specified temperature, and then extending the device into a hot autoignition chamber until autoignition occurs. Personnel are remote from the chamber during the extension into the hot chamber. The autoignition chamber, a commercially produced tubular furnace, has a 230-V, single-phase, 60-Hz electrical supply, with a total power output of 2,400 W. It has a 6-in. (15.2-cm) inner diameter, a 12-in. (30.4-cm) outer diameter and a 12-in.- long (30.4-cm), single-zone, solid tubular furnace (element) capable of heating to temperatures up to 2,012 F (1,100 C) in air.

  5. Aging tests of full scale CMS muon cathode strip chambers

    Energy Technology Data Exchange (ETDEWEB)

    D. Acosta et al.

    2003-10-15

    Two CMS production Cathode Strip Chambers were tested for aging effects in the high radiation environment at the Gamma Irradiation Facility at CERN. The chambers were irradiated over a large area: in total, about 2.1 m{sup 2} or 700 m of wire in each chamber. The 40% Ar+50%CO{sub 2}+10%CF{sub 4} gas mixture was provided by an open-loop gas system for one of the chambers and by closed-loop recirculating gas system for the other. After accumulating 0.3-0.4 C per centimeter of a wire, which is equivalent to operation during about 30-50 years at the peak LHC luminosity, no significant changes in gas gain, chamber efficiency, and wire signal noise were observed for either of the two chambers. The only consistent signs of aging were a small increase in dark current from {approx}2 nA to {approx}10 nA per plane of 600 wires and a decrease of strip-to-strip resistance from 1000 G{Omega} to 10-100 G{Omega}. Disassembly of the chambers revealed deposits on the cathode planes, while the anode wires remained fairly clean.

  6. Design and testing of a model CELSS chamber robot

    Science.gov (United States)

    Davis, Mark; Dezego, Shawn; Jones, Kinzy; Kewley, Christopher; Langlais, Mike; Mccarthy, John; Penny, Damon; Bonner, Tom; Funderburke, C. Ashley; Hailey, Ruth

    1994-01-01

    A robot system for use in an enclosed environment was designed and tested. The conceptual design will be used to assist in research performed by the Controlled Ecological Life Support System (CELSS) project. Design specifications include maximum load capacity, operation at specified environmental conditions, low maintenance, and safety. The robot system must not be hazardous to the sealed environment, and be capable of stowing and deploying within a minimum area of the CELSS chamber facility. This design consists of a telescoping robot arm that slides vertically on a shaft positioned in the center of the CELSS chamber. The telescoping robot arm consists of a series of links which can be fully extended to a length equal to the radius of the working envelope of the CELSS chamber. The vertical motion of the robot arm is achieved through the use of a combination ball screw/ball spline actuator system. The robot arm rotates cylindrically about the vertical axis through use of a turntable bearing attached to a central mounting structure fitted to the actuator shaft. The shaft is installed in an overhead rail system allowing the entire structure to be stowed and deployed within the CELSS chamber. The overhead rail system is located above the chamber's upper lamps and extends to the center of the CELSS chamber. The mounting interface of the actuator shaft and rail system allows the entire actuator shaft to be detached and removed from the CELSS chamber. When the actuator shaft is deployed, it is held fixed at the bottom of the chamber by placing a square knob on the bottom of the shaft into a recessed square fitting in the bottom of the chamber floor. A support boot ensures the rigidity of the shaft. Three student teams combined into one group designed a model of the CELSS chamber robot that they could build. They investigated materials, availability, and strength in their design. After the model arm and stand were built, the class performed pre-tests on the entire system

  7. Design and testing of a model CELSS chamber robot

    Science.gov (United States)

    Davis, Mark; Dezego, Shawn; Jones, Kinzy; Kewley, Christopher; Langlais, Mike; McCarthy, John; Penny, Damon; Bonner, Tom; Funderburke, C. Ashley; Hailey, Ruth

    1994-08-01

    A robot system for use in an enclosed environment was designed and tested. The conceptual design will be used to assist in research performed by the Controlled Ecological Life Support System (CELSS) project. Design specifications include maximum load capacity, operation at specified environmental conditions, low maintenance, and safety. The robot system must not be hazardous to the sealed environment, and be capable of stowing and deploying within a minimum area of the CELSS chamber facility. This design consists of a telescoping robot arm that slides vertically on a shaft positioned in the center of the CELSS chamber. The telescoping robot arm consists of a series of links which can be fully extended to a length equal to the radius of the working envelope of the CELSS chamber. The vertical motion of the robot arm is achieved through the use of a combination ball screw/ball spline actuator system. The robot arm rotates cylindrically about the vertical axis through use of a turntable bearing attached to a central mounting structure fitted to the actuator shaft. The shaft is installed in an overhead rail system allowing the entire structure to be stowed and deployed within the CELSS chamber. The overhead rail system is located above the chamber's upper lamps and extends to the center of the CELSS chamber. The mounting interface of the actuator shaft and rail system allows the entire actuator shaft to be detached and removed from the CELSS chamber. When the actuator shaft is deployed, it is held fixed at the bottom of the chamber by placing a square knob on the bottom of the shaft into a recessed square fitting in the bottom of the chamber floor. A support boot ensures the rigidity of the shaft. Three student teams combined into one group designed a model of the CELSS chamber robot that they could build. They investigated materials, availability, and strength in their design. After the model arm and stand were built, the class performed pre-tests on the entire system

  8. Characteristics of an anechoic chamber for fan noise testing

    Science.gov (United States)

    Wazyniak, J. A.; Shaw, L. M.; Essary, J. D.

    1977-01-01

    Acoustical and mechanical design features of NASA Lewis Research Center's engine fan noise facility are described. Acoustic evaluation of the 1420-m (50,000-ft) chamber, which is lined with an array of stepped wedges, is described. Results from the evaluation in terms of cut-off frequency and non-anechoic areas near the walls are detailed. Fan models with 0.51-m (20-in) diameters are electrically driven to 20,600 rpm in either the inlet mode (drawing air from the chamber) or exhaust mode (discharging air into the chamber) to facilitate study of both fore and aft fan noise. Inlet noise characteristics of the first fan tested, the JT8D Refan, are discussed and compared to full-scale levels. Turbulence properties of the inlet flow and acoustic results are compared with and without a turbulence reducing screen over the fan inlet.

  9. Materials screening chamber for testing materials resistance to atomic oxygen

    Science.gov (United States)

    Pippin, H. G.; Carruth, Ralph

    1989-01-01

    A unique test chamber for exposing material to a known flux of oxygen atoms is described. The capabilities and operating parameters of the apparatus include production of an oxygen atom flux in excess of 5 x 10 to the 16th atoms/sq cm-sec, controlled heating of the sample specimen, RF circuitry to contain the plasma within a small volume, and long exposure times. Flux measurement capabilities include a calorimetric probe and a light titration system. Accuracy and limitations of these techniques are discussed. An extension to the main chamber to allow simultaneous ultraviolet and atomic oxygen exposure is discussed. The oxygen atoms produced are at thermal energies. Sample specimens are maintained at any selected temperature between ambient and 200 C, to within + or - 2 C. A representative example of measurements made using the chamber is presented.

  10. Development and construction of a specific chamber for phototoxicity test

    Energy Technology Data Exchange (ETDEWEB)

    Sufi, Bianca S.; Mathor, Monica B., E-mail: biancasufi@usp.br, E-mail: mathor@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Esteves-Pedro, Natalia M.; Kaneko, Telma Mary, E-mail: nataliamenves@yahoo.com.br, E-mail: tsakuda@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Fac. de Ciencias Farmaceuticas; Lopes, Patricia, E-mail: patricia.lopes@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Diadema, SP (Brazil)

    2013-07-01

    Phototoxicity corresponds to the acute toxic response induced after skin exposure 'in vivo' and 'ex vivo' to certain chemicals and subsequent exposure to irradiation. Phototoxicity 'in vitro' assay is determined by viability of fibroblasts BALB/c 3T3 exposed to chemicals in the presence and absence of light. Substances identified as phototoxic are susceptible to 'in vivo' phototoxicity (OECD 432, 2004). A chamber was developed and constructed according to the guidelines OECD Toxicity Guide - 432 and ®ECVAM DB-ALM: INVITTOX N. 78. The chamber was built in stainless steel frame, with UVA lamps and dark area for negative control. The tests to qualify the chamber were performed with Sodium Lauryl Sulfate, recommended by the guides aforementioned, as negative control; and Bergamot oil (Givaudan-Roche), as positive control. Bergamot, Citrus bergamia, has, as major component, Bergapten responsible for its photosensitive activity. Both samples were diluted in Phosphate Buffered Saline with concentrations between 0.005 and 0.1 mg/mL, which were calculated by the dilution factor 1.47. These tests were performed over fibroblast BALB/c 3T3 culture and submitted to phototoxicity assay with MTS dye, under spectrophotometric reading, which allows determining the Photo Irritation Factor (PIF), what suggests that a substance with a PIF<2 predicts no phototoxicity; PIF>2 and <5 provides likely phototoxicity and PIF>5 provides phototoxicity. Sodium Lauryl Sulfate presented a PIF=1, being in accordance with the OECD. Bergamot oil has shown to be likely phototoxic with a PIF=2,475. These results provide that the chamber is qualified to be used to perform phototoxicity tests with assurance and security. (author)

  11. Aerospace Structures Test Facility Environmental Test Chambers (ETC)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The ETCs test the structural integrity of aerospace structures in representative operating temperatures and aerodynamic load distributions. The test article...

  12. Specialized Environmental Chamber Test Complex: User Test Planning Guide

    Science.gov (United States)

    Montz, Michael E.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the Specialized Environmental Test Complex. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  13. Conceptual Design Report for the Extreme Ecosystems Test Chambers

    Energy Technology Data Exchange (ETDEWEB)

    C. Barnes; J. Beller; K. Caldwell; K. Croft; R. Cherry; W. Landman

    1998-12-01

    This conceptual design supports the creation of Extreme Ecosystems Test Chambers, which will replicate deep subsurface and subocean environments characterized by high pressure (2,000 psi) and subfreezing to high temperature (-4 to 300 degrees F) with differing chemical and saturation conditions. The design provides a system to support research and development that includes heat transfer, phase change issues in porous media, microbiology in extreme environments, and carbon sequestration and extraction. The initial system design is based on the research needs to support the commercial production of methane hydrates from subsurface sediments. The design provides for three pressure vessels: a Down Hole Test Vessel, a Vertical Multi-phase Test Vessel, and a Horizontal Multi-phase Test Vessel.

  14. Scale testing of a partially confined blast chamber

    CSIR Research Space (South Africa)

    Grundling, W

    2012-10-01

    Full Text Available at the peak pressure readings from the confined and unconfined graphs, it is clear that in both cases the pressure has increased by partially confining the open side by 65%. Face-on pressure increased from 1 MPa up to 1.7 Mpa, while side-on pressure... readings increased from 0.8 MPa to 0.95 MPa in the confined state. It is recommended that more tests are done within the scaled blast chamber to retrieve repeatability in measurement results. Up-scaling of the pendulum to cover the full-size blast...

  15. MIMO OTA Testing in Small Multi-Probe Anechoic Chamber Setups

    OpenAIRE

    Llorente, Ines Carton; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    OTA testing of MIMO capable terminals is often performed in large anechoic chambers, where planar waves impinging the test area are assumed. Furthermore, reflections from the chamber, and probe coupling are often considered negligible due to the large dimensions of the chamber. This paper investigates the feasibility of reducing the physical dimension of 2D multi-probe anechoic chamber setups for MIMO OTA testing, with the purpose of reducing the cost and space of the setup. In the paper, a c...

  16. Structural Benchmark Tests of Composite Combustion Chamber Support Completed

    Science.gov (United States)

    Krause, David L.; Thesken, John C.; Shin, E. Eugene; Sutter, James K.

    2005-01-01

    A series of mechanical load tests was completed on several novel design concepts for extremely lightweight combustion chamber support structures at the NASA Glenn Research Center (http://www.nasa.gov/glenn/). The tests included compliance evaluation, preliminary proof loadings, high-strain cyclic testing, and finally residual strength testing of each design (see the photograph on the left). Loads were applied with single rollers (see the photograph on the right) or pressure plates (not shown) located midspan on each side to minimize the influence of contact stresses on corner deformation measurements. Where rollers alone were used, a more severe structural loading was produced than the corresponding equal-force pressure loading: the maximum transverse shear force existed over the entire length of each side, and the corner bending moments were greater than for a distributed (pressure) loading. Failure modes initiating at the corner only provided a qualitative indication of the performance limitations since the stress state was not identical to internal pressure. Configurations were tested at both room and elevated temperatures. Experimental results were used to evaluate analytical prediction tools and finite-element methodologies for future work, and they were essential to provide insight into the deformation at the corners. The tests also were used to assess fabrication and bonding details for the complicated structures. They will be used to further optimize the design of the support structures for weight performance and the efficacy of corner reinforcement.

  17. MIMO OTA Testing in Small Multi-Probe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Llorente, Ines Carton; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    investigates the feasibility of reducing the physical dimension of 2D multi-probe anechoic chamber setups for MIMO OTA testing, with the purpose of reducing the cost and space of the setup. In the paper, a channel emulation algorithm and chamber compensation technique are proposed for MIMO OTA testing in small......OTA testing of MIMO capable terminals is often performed in large anechoic chambers, where planar waves impinging the test area are assumed. Furthermore, reflections from the chamber, and probe coupling are often considered negligible due to the large dimensions of the chamber. This paper...

  18. Construction and test of sMDT chambers for the ATLAS muon spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Takasugi, Eric; Schmidt-Sommerfeld, Korbinian; Kortner, Oliver; Kroha, Hubert [Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2016-07-01

    In the ATLAS muon spectrometer, Monitored Drift Tube chambers (MDTs) are used for precise tracking measurements. In order to increase the geometric acceptance and rate capability, new chambers have been designed and are under construction to be installed in ATLAS during the winter shutdown of 2016/17 of the LHC. The new chambers have a drift tube diameter of 15 mm (compared to 30 mm of the other MDTs) and are therefore called sMDT chambers. This presentation reports on the progress of chamber construction and on the results of quality assurance tests.

  19. Cosmic ray tests of large area Multigap Resistive Plate Chambers

    CERN Document Server

    An, S; Kim, J; Williams, M C S; Zichichi, A; Zuyeuski, R

    2007-01-01

    We have built Multigap Resistive Plate Chambers (MRPC) with six gas gaps and an active area of . The signals are generated on 2.5 cm wide copper pickup strips; these are read out at each end thus allowing the position of the hit along the strip to be obtained from the time difference. Using three of these chambers we have set up a cosmic tracking system in a similar manner as planned for the Extreme Energy Events (EEE) project. The details of the set-up are presented in this paper. In addition we discuss the time and position resolution of these MRPCs measured using cosmic rays.

  20. A beam test of prototype time projection chamber using micro ...

    Indian Academy of Sciences (India)

    Keywords. Time projection chamber; micro-pattern gas detectors; micro-mesh gaseous structure; gas electron multiplier; international linear collider; spatial resolution. ... Makoto Kobayashi1 on behalf of part of the ILC{TPC Collaboration. High Energy Accelerator Organization (KEK), Tsukuba 305-0801, Japan ...

  1. Analysis of Anechoic Chamber Testing of the Hurricane Imaging Radiometer

    Science.gov (United States)

    Fenigstein, David; Ruf, Chris; James, Mark; Simmons, David; Miller, Timothy; Buckley, Courtney

    2010-01-01

    The Hurricane Imaging Radiometer System (HIRAD) is a new airborne passive microwave remote sensor developed to observe hurricanes. HIRAD incorporates synthetic thinned array radiometry technology, which use Fourier synthesis to reconstruct images from an array of correlated antenna elements. The HIRAD system response to a point emitter has been measured in an anechoic chamber. With this data, a Fourier inversion image reconstruction algorithm has been developed. Performance analysis of the apparatus is presented, along with an overview of the image reconstruction algorithm

  2. Calibration of Virtual Testing Stand of the Car Cabin using climatic chamber tests

    Directory of Open Access Journals (Sweden)

    Pokorny Jan

    2015-01-01

    Full Text Available The aim of our research is to calibrate and verify of the software Virtual Testing Stand of the Car Cabin using climatic chamber tests. The Virtual Testing Stand is standalone executable software developed in Matlab for prediction of the cabin environment and thermal heat load by using the time-efficient heat balance model. The main limitation of the simulation method is a simplified convection scheme inside a cabin using the empirical correlations instead of the CFD simulations. In this paper we present the first preliminary tests of the calibration process and verification of the simulation results. Tests were carried out for the car Skoda Octavia Combi with the silver metallic paint. The material composition of the test car was deeply explored and the material properties of the cabin were identified as accurate as possible. The car was exposed to the various environments inside a climate chamber. In this paper we report about two performed tests: summer solar soak test and winter heat-up test with the defined heat source.

  3. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  4. Chamber for mechanical testing in H2 with observation by neutron scattering

    Science.gov (United States)

    Connolly, Matthew; Bradley, Peter; Slifka, Andrew; Drexler, Elizabeth

    2017-06-01

    A gas-pressure chamber has been designed, constructed, and tested at a moderate pressure (3.4 MPa, 500 psi) and has the capability of mechanical loading of steel specimens for neutron scattering measurements. The chamber will allow a variety of in situ neutron scattering measurements: in particular, diffraction, quasielastic scattering, inelastic scattering, and imaging. The chamber is compatible with load frames available at the user facilities at the NIST Center for Neutron Research and Oak Ridge National Laboratory Spallation Neutron Source. A demonstration of neutron Bragg edge imaging using the chamber is presented.

  5. The central drift chamber for the D0 experiment: Design, construction and test

    Energy Technology Data Exchange (ETDEWEB)

    Behnke, Ties [State Univ. of New York (SUNY), Stony Brook, NY (United States)

    1989-08-01

    A cylindrical drift chamber has been designed and built at the State University of New York at Stony Brook. This chamber is to be installed in the D0 detector which is being completed at the Fermi National Accelerator. In this dissertation the design, construction and testing of this chamber are described. The characteristic features of this chamber are cells formed by solid walls and a modular structure. Much discussion is given to the performance of and results from a chamber made from three final modules which was installed in the D0 interaction region during the 1988/1989 collider run. Using this chamber proton anti-proton interactions were measured at the D0 interaction point.

  6. Redesign and Test of an SSME Turbopump for the Large Throat Main Combustion Chamber

    Science.gov (United States)

    Lunde, K. J.; Lee, G. A.; Eastland, A. H.; Rojas, L.

    1994-01-01

    The preburner oxidizer turbopump for the Space Shuttle Main Engine (SSME) was successfully redesigned for use with the Large Throat Main Combustion Chamber (LTMCC) and tested in air utilizing rapid prototyping. The redesign increases the SSME's operating range with the current Main Combustion Chamber (MCC) while achieving full operational range with the LTMCC. The use of rapid prototyping and air testing to validate the redesign demonstrated the ability to design, fabricate and test designs rapidly and at a very low cost.

  7. Radiated Immunity Testing of a Device with an External Wire: Repeatibility of Reverberation Chamber Results and Correlation with Anechoic Chamber Results

    OpenAIRE

    Canavero, Flavio

    2003-01-01

    We present the experimental radiated immunity results of an electronic device with an external wire obtained in reverberation and anechoic chambers. Repeatability and reproducibility of reverberation chamber measurements are investigated by repeating the test in three reverberation chambers with different characteristics. We show how the current state of the art allows a statistical control of RC measurement repeatability within an industrial installation, and that a statistical correlation w...

  8. Test and characterization of multigap resistive plate chambers for the EEE project

    Science.gov (United States)

    Bossini, E.; EEE Collaboration

    2016-03-01

    The Extreme Energy Events project is based on the deployment of cosmic-ray telescopes in Italian high schools with the active contribution of students and teachers. Each telescope is made by three Multigap Resistive Plate Chambers readout by strips. With around 50 telescopes already built and others under construction, specific systems to test and characterize the chambers are needed. In this article I will present a flexible and software-configurable solution to perform chamber efficiency studies with a set of scintillators and hardware to automatically scan detector strips to identify electrical issues. Both systems can provide accurate information but at the same time they can be easily operated by students.

  9. Test and characterization of multigap resistive plate chambers for the EEE project

    CERN Document Server

    Bossini, E

    2016-01-01

    The Extreme Energy Events project is based on the deployment of cosmic-ray telescopes in Italian high schools with the active contribution of students and teachers. Each telescope is made by three Multigap Resistive Plate Chambers readout by strips. With around 50 telescopes already built and others under construction, specific systems to test and characterize the chambers are needed. In this article I will present a flexible and software-configurable solution to perform chamber efficiency studies with a set of scintillators and hardware to automatically scan detector strips to identify electrical issues. Both systems can provide accurate information but at the same time they can be easily operated by students.

  10. Review of chamber design requirements for testing of personal protective clothing ensembles.

    Science.gov (United States)

    Gao, Pengfei; King, William P; Shaffer, Ronald

    2007-08-01

    This review focuses on the physical requirements for conducting ensemble testing and describes the salient issues that organizations involved in the design, test, or certification of personal protective equipment (PPE) and protective clothing ensembles need to consider for strategic planning. Several current and proposed PPE ensemble test practices and standards were identified. The man-in-simulant test (MIST) is the primary procedure used by the military to evaluate clothing ensembles for protection against chemical and biological warfare agents. MIST has been incorporated into the current editions of protective clothing and equipment standards promulgated by the National Fire Protection Association (NFPA). ASTM has recently developed a new test method (ASTM F 2588-06) for MIST evaluation of protective ensembles. Other relevant test methods include those described in International Organization for Standardization (ISO) standards. The primary differences among the test methods were the choice of test challenge material (e.g., sulfur hexafluoride, methyl salicylate, sodium chloride particles, corn oil, fluorophore-impregnated silica) and the exercise protocol for the subject(s). Although ensemble test methods and standards provide detailed descriptions of the test procedures, none give specific requirements for chamber design. A literature survey identified 28 whole-body exposure chambers that have been or could potentially be used for testing protective clothing ensembles using human test subjects. Median chamber size, median floor space, and median volume per subject were calculated from 15 chambers (involving human test subjects), where size information is available. Based on the literature survey of existing chambers and the review of the current and proposed standards and test methods, chamber design requirements will be dictated by the test methods selected. Due to widely different test conditions for aerosol/particulate and vapor ensemble testing, it is

  11. A Tale of Two Chambers: Iterative Approaches and Lessons Learned from Life Support Systems Testing in Altitude Chambers

    Science.gov (United States)

    Callini, Gianluca

    2016-01-01

    The drive for the journey to Mars is in a higher gear than ever before. We are developing new spacecraft and life support systems to take humans to the Red Planet. The journey that development hardware takes before its final incarnation in a fully integrated spacecraft can take years, as is the case for the Orion environmental control and life support system (ECLSS). Through the Pressure Integrated Suit Test (PIST) series, NASA personnel at Johnson Space Center have been characterizing the behavior of a closed loop ECLSS in the event of cabin depressurization. This kind of testing - one of the most hazardous activities performed at JSC - requires an iterative approach, increasing in complexity and hazards). The PIST series, conducted in the Crew and Thermal Systems Division (CTSD) 11-ft Chamber, started with unmanned test precursors before moving to a human-in-the-loop phase, and continues to evolve with the eventual goal of a qualification test for the final system that will be installed on Orion. Meanwhile, the Human Exploration Spacecraft Testbed for Integration and Advancement (HESTIA) program is an effort to research and develop technologies that will work in concert to support habitation on Mars. September 2015 marked the first unmanned HESTIA test, with the goal of characterizing how ECLSS technologies work together in a closed environment. HESTIA will culminate in crewed testing, but it can benefit from the lessons learned from another test that is farther ahead in its development and life cycle. Discussing PIST and HESTIA, this paper illustrates how we approach testing, the kind of information that facility teams need to ensure efficient collaborations and successful testing, and how we can apply what we learn to execute future tests.

  12. A beam test of prototype time projection chamber using micro ...

    Indian Academy of Sciences (India)

    Abstract. We conducted a series of beam tests of prototype TPCs for the international linear collider (ILC) experiment, equipped with an MWPC, a MicroMEGAS, or GEMs as a readout device. The prototype operated successfully in a test beam at KEK under an axial magnetic field of up to 1 T. The analysis of data is now in ...

  13. A permeation-controlled formaldehyde reference source for application in environmental test chambers.

    Science.gov (United States)

    Salthammer, Tunga; Giesen, Ruth; Schripp, Tobias

    2017-10-01

    In a wide range of indoor air pollutants, formaldehyde is one of the most-used and best-known substances. In order to protect human health, many countries have established threshold values for the release of formaldehyde from miscellaneous products and revise them constantly. Compliance with these regulations is usually assessed by emission test chamber measurements or derived methods. To control and improve the mechanisms of an emission test chamber, a reliable reference source with sample mimicking emission properties is required but not available so far. This study describes a permeation-controlled reference source based on the application of paraformaldehyde as formaldehyde releasing polymeric compound. Interactions between the formaldehyde release of the source and the governing chamber parameters temperature, relative humidity and air velocity were investigated in 1 m(3) emission chambers. Depending on the conditions, constant formaldehyde concentrations between approximately 10 ppb and 150 ppb can be adjusted for up to 600 h. A linear correlation between the logarithm of the chamber concentration and the reciprocal temperature was found. The results support the feasibility of the source for validation of emission test chamber performance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Development and Hotfire Testing of Additively Manufactured Copper Combustion Chambers for Liquid Rocket Engine Applications

    Science.gov (United States)

    Gradl, Paul R.; Greene, Sandy; Protz, Chris

    2017-01-01

    NASA and industry partners are working towards fabrication process development to reduce costs and schedules associated with manufacturing liquid rocket engine components with the goal of reducing overall mission costs. One such technique being evaluated is powder-bed fusion or selective laser melting (SLM), commonly referred to as additive manufacturing (AM). The NASA Low Cost Upper Stage Propulsion (LCUSP) program was designed to develop processes and material characterization for GRCop-84 (a NASA Glenn Research Center-developed copper, chrome, niobium alloy) commensurate with powder bed AM, evaluate bimetallic deposition, and complete testing of a full scale combustion chamber. As part of this development, the process has been transferred to industry partners to enable a long-term supply chain of monolithic copper combustion chambers. To advance the processes further and allow for optimization with multiple materials, NASA is also investigating the feasibility of bimetallic AM chambers. In addition to the LCUSP program, NASA’s Marshall Space Flight Center (MSFC) has completed a series of development programs and hot-fire tests to demonstrate SLM GRCop-84 and other AM techniques. MSFC’s efforts include a 4,000 pounds-force thrust liquid oxygen/methane (LOX/CH4) combustion chamber. Small thrust chambers for 1,200 pounds-force LOX/hydrogen (H2) applications have also been designed and fabricated with SLM GRCop-84. Similar chambers have also completed development with an Inconel 625 jacket bonded to the GRCop-84 material, evaluating direct metal deposition (DMD) laser- and arc-based techniques. The same technologies for these lower thrust applications are being applied to 25,000-35,000 pounds-force main combustion chamber (MCC) designs. This paper describes the design, development, manufacturing and testing of these numerous combustion chambers, and the associated lessons learned throughout their design and development processes.

  15. Development and test of combustion chamber for Stirling engine heated by natural gas

    Science.gov (United States)

    Li, Tie; Song, Xiange; Gui, Xiaohong; Tang, Dawei; Li, Zhigang; Cao, Wenyu

    2014-04-01

    The combustion chamber is an important component for the Stirling engine heated by natural gas. In the paper, we develop a combustion chamber for the Stirling engine which aims to generate 3˜5 kWe electric power. The combustion chamber includes three main components: combustion module, heat exchange cavity and thermal head. Its feature is that the structure can divide "combustion" process and "heat transfer" process into two apparent individual steps and make them happen one by one. Since natural gas can mix with air fully before burning, the combustion process can be easily completed without the second wind. The flame can avoid contacting the thermal head of Stirling engine, and the temperature fields can be easily controlled. The designed combustion chamber is manufactured and its performance is tested by an experiment which includes two steps. The experimental result of the first step proves that the mixture of air and natural gas can be easily ignited and the flame burns stably. In the second step of experiment, the combustion heat flux can reach 20 kW, and the energy utilization efficiency of thermal head has exceeded 0.5. These test results show that the thermal performance of combustion chamber has reached the design goal. The designed combustion chamber can be applied to a real Stirling engine heated by natural gas which is to generate 3˜5 kWe electric power.

  16. The Cosmic Ray Hodoscopes for Testing Thin Gap Chambers at the Technion and Tel Aviv University

    CERN Document Server

    Etzion, E; Amram, N; Benhammou, Ya; Ben-Moshe, M; Bella, G; Ginzburg, J; Gernitzky, Y; Harel, A; Landsman, Hagar Yaël; Panikashvili, N; Rozen, Y; Tarem, S; Warszawski, E; Wasilewski, J; Levinson, L

    2004-01-01

    Thin gap chambers (TGCs) are built for the muon trigger chambers in the endcap region of the LHC experiment ATLAS. More than 2500 ATLAS TGCs are being produced at the Weizmann institute in Israel, and in Shandong University in China. Detailed testing of these chambers is performed at the Technion and at the Tel-Aviv University. Two cosmic ray hodoscopes for testing the operation of these detectors were built in Israel. In these hodoscopes the response of the chambers to energetic cosmic ray muons is recorded and analyzed. The hodoscopes measure the exact time and space location of the cosmic ray hit and read out the chambers which are being tested to verify that they produce a corresponding signal within the required time interval. The cosmic ray hodoscopes built at the Technion and at the Tel Aviv University for the test of ATLAS TGCs are described. The mechanical structure, readout electronics, data acquisition and operating scheme are presented. Typical TGC test results are presented and discussed.

  17. Front-end Electronics Test for the LHCb Muon Wire Chambers

    CERN Document Server

    Nobrega, R; Carboni, G; Massafferri, A; Santovetti, E

    2007-01-01

    This document describes the apparatus and procedures implemented to test Multi Wire Proportional Chambers (MWPC) after front-end assembly for the LHCb Muon Detector. Results of measurements of key noise parameters are also described. Given a fully equipped chamber, this system is able to diagnose every channel performing an analysis of front-end output drivers’ response and noise rate versus threshold. Besides, it allows to assess if the noise rate at the experiment threshold region is within appropriate limits. Aiming at an automatic, fast and user-friendly system for mass production tests of MWPC, the project has foreseen as well electronic identification of every chamber and front-end board, and data archiving in such a way to make it available to the Experiment Control System (ECS) while in operation.

  18. Cosmic ray tests of a 4.6 m-long test drift chamber for JLC

    CERN Document Server

    Kurihara, Y; Sudo, S; Abe, T; Fujii, K; Ishihara, N; Khalatyan, N; Matsui, T; Nitoh, O; Ohama, T; Okuno, H; Sugiyama, A; Takahashi, K; Watanabe, T; Yoshida, T

    2000-01-01

    Performance of a 4.6 m-long drift chamber filled with a CO sub 2 iso-butane (90:10) mixture was studied using cosmic-ray data, in the course of detector R and D for JLC. After correcting the data for wire displacements due to gravitational and electrostatic forces, a spatial resolution of 100 mu m per wire was achieved over the full length of the chamber. The relation between wire efficiency and oxygen remnant in the chamber gas is also discussed.

  19. Emulating Ray-Tracing Channels in Multi-probe Anechoic Chamber Setups for Virtual Drive Testing

    DEFF Research Database (Denmark)

    Fan, Wei; Llorente, Ines Carton; Kyösti, Pekka

    2016-01-01

    This paper discusses virtual drive testing (VDT) for multiple-input multiple-output (MIMO) capable terminals in multi-probe anechoic chamber (MPAC) setups. We propose to perform VDT, via reproducing ray tracing (RT) simulated channels with the field synthesis technique. Simulation results...

  20. On Probe Weighting for MIMO OTA testing in Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Nuutinen, Jukka-Pekka

    2015-01-01

    The multi-probe anechoic chamber method is promising for OTA testing. The reason can be attributed to its potential for enabling evaluating MIMO terminals in realistic environments. The focus of the paper is on investigating how to create desired spatial channel models with the multi-probe anechoic...... chamber setups. Simulation results have shown that with the discussed methods, the number of probes and probe power weights determine to which level the spatial characteristics of the target channel models can be accurately approximated. With the optimized weights, better agreement is achieved for all...

  1. Development and testing of a Monte Carlo code system for analysis of ionization chamber responses

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, J.O.; Gabriel, T.A.

    1986-01-01

    To predict the perturbation of interactions between radiation and material by the presence of a detector, a differential Monte Carlo computer code system entitled MICAP was developed and tested. This code system determines the neutron, photon, and total response of an ionization chamber to mixed field radiation environments. To demonstrate the ability of MICAP in calculating an ionization chamber response function, a comparison was made to 05S, an established Monte Carlo code extensively used to accurately calibrate liquid organic scintillators. Both code systems modeled an organic scintillator with a parallel beam of monoenergetic neutrons incident on the scintillator. (LEW)

  2. Anechoic chamber qualification: traverse method, inverse square law analysis method, and nature of test signal.

    Science.gov (United States)

    Cunefare, Kenneth A; Biesel, Van B; Tran, John; Rye, Ryan; Graf, Aaron; Holdhusen, Mark; Albanese, Anne-Marie

    2003-02-01

    Qualification of anechoic chambers is intended to demonstrate that the chamber supports the intended free-field environment within some permissible tolerance bounds. Key qualification issues include the method used to obtain traverse data, the analysis method for the data, and the use of pure tone or broadband noise as the chamber excitation signal. This paper evaluates the relative merits of continuous versus discrete traverses, of fixed versus optimal reference analysis of the traverse data, and of the use of pure tone versus broadband signals. The current practice of using widely space discrete sampling along a traverse is shown to inadequately sample the complexity of the sound field extant with pure tone traverses, but is suitable for broadband traverses. Continuous traverses, with spatial resolution on the order of 15% of the wavelength at the frequency of interest, are shown to be necessary to fully resolve the spatial complexity of pure tone qualifications. The use of an optimal reference method for computing the deviations from inverse square law is shown to significantly improve the apparent performance of the chamber for pure tone qualifications. Finally, the use of broadband noise as the test signal, as compared to pure tone traverses over the same span, is demonstrated to be a marginal indicator of chamber performance.

  3. Office-like Test Chambers to Measure Cool Roof Energy Savings in Four Indian Climates

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, Rathish [Saint Gobain Research India Pvt. Ltd. (India); B, Sasank [Saint Gobain Research India Pvt. Ltd. (India); T, Rajappa [Saint Gobain Research India Pvt. Ltd. (India); N, Vinay [Saint Gobain Research India Pvt. Ltd. (India); Garg, Vishal [International Inst. of Information Technology, Hyderabad (India); Reddy, Niranjan [International Inst. of Information Technology, Hyderabad (India); Levinson, Ronnen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-21

    Selecting a high albedo (solar reflectance) waterproofing layer on the top of a roof helps lower the roof’s surface temperature and reduce the air conditioning energy consumption in the top floor of a building. The annual energy savings depend on factors including weather, internal loads, and building operation schedule. To demonstrate the energy saving potential of high albedo roofs, an apparatus consisting of two nearly identical test chambers (A and B) has been built in four Indian climates: Chennai (hot & humid), Bangalore (temperate), Jhagadia (Hot & dry) and Delhi (composite). Each chamber has well-insulated walls to mimic the core of an office building. Both chambers have the same construction, equipment, and operating schedule, differing only in roof surface. The reinforced cement concrete roof of Chamber A is surfaced with a low-albedo cement layer, while that of Chamber B is surfaced with a high-albedo water proof membrane (change in solar reflectance of 0.28). The experiment will be carried out for one year to explore seasonal variations in energy savings. Initial results in the month of July (post summer) shows that savings from high albedo roof ranges from 0.04 kWh/m2/day in temperate climates, to 0.08 kWh/m2/day in hot & dry climate.

  4. Mimicking Mars: A vacuum simulation chamber for testing environmental instrumentation for Mars exploration

    Energy Technology Data Exchange (ETDEWEB)

    Sobrado, J. M., E-mail: sobradovj@inta.es; Martín-Soler, J. [Centro de Astrobiología (CAB), INTA-CSIC, Torrejón de Ardoz, 28850 Madrid (Spain); Martín-Gago, J. A. [Centro de Astrobiología (CAB), INTA-CSIC, Torrejón de Ardoz, 28850 Madrid (Spain); Instituto de Ciencias de Materiales de Madrid (ICMM-CSIC), Cantoblanco, 28049 Madrid (Spain)

    2014-03-15

    We have built a Mars environmental simulation chamber, designed to test new electromechanical devices and instruments that could be used in space missions. We have developed this environmental system aiming at validating the meteorological station Rover Environment Monitoring Station of NASA's Mars Science Laboratory mission currently installed on Curiosity rover. The vacuum chamber has been built following a modular configuration and operates at pressures ranging from 1000 to 10{sup −6} mbars, and it is possible to control the gas composition (the atmosphere) within this pressure range. The device (or sample) under study can be irradiated by an ultraviolet source and its temperature can be controlled in the range from 108 to 423 K. As an important improvement with respect to other simulation chambers, the atmospheric gas into the experimental chamber is cooled at the walls by the use of liquid-nitrogen heat exchangers. This chamber incorporates a dust generation mechanism designed to study Martian-dust deposition while modifying the conditions of temperature, and UV irradiated.

  5. Mimicking Mars: a vacuum simulation chamber for testing environmental instrumentation for Mars exploration.

    Science.gov (United States)

    Sobrado, J M; Martín-Soler, J; Martín-Gago, J A

    2014-03-01

    We have built a Mars environmental simulation chamber, designed to test new electromechanical devices and instruments that could be used in space missions. We have developed this environmental system aiming at validating the meteorological station Rover Environment Monitoring Station of NASA's Mars Science Laboratory mission currently installed on Curiosity rover. The vacuum chamber has been built following a modular configuration and operates at pressures ranging from 1000 to 10(-6) mbars, and it is possible to control the gas composition (the atmosphere) within this pressure range. The device (or sample) under study can be irradiated by an ultraviolet source and its temperature can be controlled in the range from 108 to 423 K. As an important improvement with respect to other simulation chambers, the atmospheric gas into the experimental chamber is cooled at the walls by the use of liquid-nitrogen heat exchangers. This chamber incorporates a dust generation mechanism designed to study Martian-dust deposition while modifying the conditions of temperature, and UV irradiated.

  6. Development and evaluation of an inhalation chamber for in vivo tests

    Directory of Open Access Journals (Sweden)

    EDUARDO R. DA SILVA

    2017-08-01

    Full Text Available ABSTRACT The bioavailability, toxicity, and therapeutic efficacy of a drug is directly related to its administration route. The pulmonary route can be accessed by inhalation after fumigation, vaporization or nebulization. Thus, pharmacological and toxicological evaluation accessed by an apparatus specifically designed and validated for this type of administration is extremely important. Based on pre-existing models, an inhalation chamber was developed. This presents a central structure with five animal holders. The nebulized air passes directly and continuously through these holders and subsequently to an outlet. Evaluation of its operation was performed using clove essential oil, a nebulizer, and a flow meter. The air within the chamber was collected by static headspace and analyzed by gas chromatography with a flame ionization detector. For this purpose, a 2.5 minutes chromatographic method was developed. The air flow in each of the five outputs was 0.92 liters per minute. During the first minute, the chamber became saturated with the nebulized material. Homogeneous and continuous operation of the chamber was observed without accumulation of volatile material inside it for 25 minutes. The inhalation chamber works satisfactorily for in vivo tests with medicines designed to be administrated by inhalation.

  7. LHCb: Performance of the fourgap LHCb Muon Chambers tested with cosmic rays

    CERN Multimedia

    Pinci, D

    2007-01-01

    The LHCb Muon System is composed of five detection stations (M1M5)mainly equipped with a total of 1368 MultiWire Proportional Chambers (MWPC). MWPCs need to ensure a high detection efficiency, a fast response and a good space resolution. We present here the results of detailed studies of the performance of different fourgap chambers, completely equipped with the final FrontEnd Electronics, measured with cosmic rays. Aspects such as time resolution, hit multiplicity and time and space structure of the crosstalk hits were measured. For the first time, both types of chambers, those with anodewirereadout and those with cathodepadreadout, were tested and the results are compared. Results hereby obtained will be used to individuate the optimal working conditions of the apparatus and to achieve a more realistic detector description in the LHCb Monte Carlo simulation.

  8. Development of eddy current testing system for inspection of combustion chambers of liquid rocket engines.

    Science.gov (United States)

    He, D F; Zhang, Y Z; Shiwa, M; Moriya, S

    2013-01-01

    An eddy current testing (ECT) system using a high sensitive anisotropic magnetoresistive (AMR) sensor was developed. In this system, a 20 turn circular coil with a diameter of 3 mm was used to produce the excitation field. A high sensitivity AMR sensor was used to measure the magnetic field produced by the induced eddy currents. A specimen made of copper alloy was prepared to simulate the combustion chamber of liquid rocket. Scanning was realized by rotating the chamber with a motor. To reduce the influence of liftoff variance during scanning, a dual frequency excitation method was used. The experimental results proved that ECT system with an AMR sensor could be used to check liquid rocket combustion chamber.

  9. Initial test results of an ionization chamber shower detector for a LHC luminosity monitor

    CERN Document Server

    Datte, P S; Haguenauer, Maurice; Manfredi, P F; Manghisoni, M; Millaud, J E; Placidi, Massimo; Ratti, L; Riot, V J; Schmickler, Hermann; Speziali, V; Traversi, G; Turner, W C

    2003-01-01

    A novel segmented multigap pressurized gas ionization chamber is being developed for optimization of the luminosity of the Large Hadron Collider (LHC). The ionization chambers are to be installed in the front quadrupole and 0 degrees neutral particle absorbers in the high luminosity interaction regions (IRs) and sample the energy deposited near the maxima of the hadronic/electromagnetic showers in these absorbers. The ionization chambers are instrumented with low noise, fast pulse-shaping electronics to be capable of resolving individual bunch crossings at 40 MHz. In this paper, we report the initial results of our second test of this instrumentation in a super proton synchrotron (SPS) external proton beam. Single 300 GeV protons are used to simulate the hadronic/electromagnetic showers produced by the forward collision products from the interaction regions of the LHC. The capability of instrumentation to measure the luminosity of individual bunches in a 40 MHz bunch train is demonstrated. (10 refs) .

  10. Reverberation Chamber Uniformity Validation and Radiated Susceptibility Test Procedures for the NASA High Intensity Radiated Fields Laboratory

    Science.gov (United States)

    Koppen, Sandra V.; Nguyen, Truong X.; Mielnik, John J.

    2010-01-01

    The NASA Langley Research Center's High Intensity Radiated Fields Laboratory has developed a capability based on the RTCA/DO-160F Section 20 guidelines for radiated electromagnetic susceptibility testing in reverberation chambers. Phase 1 of the test procedure utilizes mode-tuned stirrer techniques and E-field probe measurements to validate chamber uniformity, determines chamber loading effects, and defines a radiated susceptibility test process. The test procedure is segmented into numbered operations that are largely software controlled. This document is intended as a laboratory test reference and includes diagrams of test setups, equipment lists, as well as test results and analysis. Phase 2 of development is discussed.

  11. Experimental Evaluation of User Influence on Test Zone Size in Multi-probe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Ji, Yilin

    2017-01-01

    Over-the-air (OTA) radiated testing for multipleinput multiple-output (MIMO) capable mobile terminals has been actively discussed in the standardization in recent years, where multi-probe anechoic chamber (MPAC) method has been selected, together with the radiated two-stage (RTS) method. The supp......Over-the-air (OTA) radiated testing for multipleinput multiple-output (MIMO) capable mobile terminals has been actively discussed in the standardization in recent years, where multi-probe anechoic chamber (MPAC) method has been selected, together with the radiated two-stage (RTS) method...... available in the literature are typically limited to free space scenarios, where no user effect in the vicinity of MIMO terminal is present. There is a concern whether or not the test zone size should encompass the user phantom, together with the mobile terminal in the MPAC setup. To address this issue...

  12. Design, Development and Hotfire Testing of Monolithic Copper and Bimetallic Additively Manufactured Combustion Chambers

    Science.gov (United States)

    Gradl, Paul; Barnett, Greg; Brandsmeier, Will; Greene, Sandy Elam; Protz, Chris

    2016-01-01

    NASA and industry partners are working towards fabrication process development to reduce costs and schedules associated with manufacturing liquid rocket engine components with the goal of reducing overall mission costs. One such technique being evaluated is powder-bed fusion or selective laser melting (SLM) otherwise commonly referred to as additive manufacturing. The NASA Low Cost Upper Stage Propulsion (LCUSP) program was designed to develop processes and material characterization for the GRCop-84 copper-alloy commensurate with powder bed additive manufacturing, evaluate bimetallic deposition and complete testing of a full scale combustion chamber. As part of this development, the process has been transferred to industry partners to enable a long-term supply chain of monolithic copper combustion chambers. As a direct spin off of this program, NASA is working with industry partners to further develop the printing process for the GRCop-84 material in addition to the C-18150 (CuCrZr) material. To advance the process further and allow for optimization with multiple materials, NASA is also investigating the feasibility of bimetallic additively manufactured chambers. A 1.2k sized thrust-chamber was designed and developed to compare the printing process of the GRCop-84 and C-18150 SLM materials. A series of similar MCC liners also completed development with an Inconel 625 jacket bonded to the GRcop-84 liner evaluating direct metal deposition (DMD) laser and arc-based techniques. This paper describes the design, development, manufacturing and testing of these combustion chambers and associated lessons learned throughout the design and development process.

  13. Testing of Nanoparticle Release from a Composite Containing Nanomaterial Using a Chamber System.

    Science.gov (United States)

    Lee, Gun Ho; Ahn, Kang-Ho; Yu, Il Je

    2016-11-22

    With the rapid development of nanotechnology as one of the most important technologies in the 21 st century, interest in the safety of consumer products containing nanomaterials is also increasing. Evaluating the nanomaterial release from products containing nanomaterials is a crucial step in assessing the safety of these products, and has resulted in several international efforts to develop consistent and reliable technologies for standardizing the evaluation of nanomaterial release. In this study, the release of nanomaterials from products containing nanomaterials is evaluated using a chamber system that includes a condensation particle counter, optical particle counter, and sampling ports to collect filter samples for electron microscopy analysis. The proposed chamber system is tested using an abrasor and disc-type nanocomposite material specimens to determine whether the nanomaterial release is repeatable and consistent within an acceptable range. The test results indicate that the total number of particles in each test is within 20% from the average after several trials. The release trends are similar and they show very good repeatability. Therefore, the proposed chamber system can be effectively used for nanomaterial release testing of products containing nanomaterials.

  14. Use of an annular chamber for testing thermal preference of westslope cutthroat trout and rainbow trout

    Science.gov (United States)

    McMahon, T.E.; Bear, E.A.; Zale, A.V.

    2008-01-01

    Remaining populations of westslope cutthroat trout (Oncorhynchus clarkii lewisi) in western North America are primarily confined to cold headwaters whereas nonnative rainbow trout (Oncorhynchus mykiss) predominate in warmer, lower elevation stream sections historically occupied by westslope cutthroat trout. We tested whether differing thermal preferences could account for the spatial segregation observed in the field. Thermal preferences of age-1 westslope cutthroat trout and rainbow trout (125 to 150 mm total length) were assessed in the laboratory using a modified annular preference chamber at acclimation temperatures of 10, 12, 14, and 16??C Final preferred temperature of westslope cutthroat trout (14.9??C) was similar to that of rainbow trout (14.8??C) when tested in a thermal gradient of 11-17??C The high degree of overlap in thermal preference indicates the two species have similar thermal niches and a high potential for competition. We suggest several modifications to the annular preference chamber to improve performance in future studies.

  15. Stability of selected volatile contact allergens in different patch test chambers under different storage conditions

    DEFF Research Database (Denmark)

    Mose, Kristian Fredløv; Andersen, Klaus Ejner; Christensen, Lars Porskjaer

    2012-01-01

    storage conditions. Methods. Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber™, IQ Ultimate™, and Van der Bend® transport...... during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend® transport container, the contact allergens exhibited acceptable stability under...... both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. Conclusion. The Van der Bend® transport container was the best device for storage of samples of volatile contact allergens....

  16. Accelerated aging test of solar mirrors: Comparison of different UV chambers

    Science.gov (United States)

    Avenel, Coralie; Gardette, Jean-Luc; Therias, Sandrine; Disdier, Angela; Raccurt, Olivier

    2017-06-01

    This study aimed to compare three accelerated aging chambers with different lamps and irradiance levels: Suntest XXL+ and Sepap 12/24 from ATLAS MTS and UV5X from AMC/AMTC. Five kinds of solar mirrors were tested: thin and thick monolithic glass, laminated glass, aluminum and a glass mirror stick on a composite polymer substrate. All samples were aged under irradiation with a temperature set onto 70 °C. Temperatures were measured directly onto samples in addition to the chamber value. Temperature was kept constant and equal in each device in order to get the same acceleration factor due to temperature for all aging. This allowed comparing the effect of irradiation only. Specular reflectance was measured at several intervals during aging, and silver and paints surfaces were monitored by optical microscopy. This study is included in the framework of the STAGE-STE European project. One of the objectives is to establish a standard for CSP mirrors accelerated aging tests. Results of aging are needed to understand which tests are relevant to each available technology of mirror. Furthermore, a standard aimed to be applied in any device which can reach required conditions, so influence of these devices has to be known to ensure the reproducibility of aging between chambers and laboratories.

  17. Cryogenic Testing of the Thermal Vacuum Chamber and Ground Support Equipment for the James Webb Space Telescope in Chamber A at Johnson Space Center

    Science.gov (United States)

    DiPirro, M.; Homan, J.; Havey, K.; Ousley, W.

    2017-01-01

    The James Webb Space Telescope (JWST) is the largest cryogenic instrument telescope to be developed for space flight. The telescope will be passively cooled to 50 K and the instrument package will be at 40 K with the mid-infrared instrument at 6 K. The final cryogenic test of the Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) as an assembly (OTE + ISIM OTIS) will be performed in the largest 15 K chamber in the world, Chamber A at Johnson Space Center. The planned duration of this test will be 100 days in the middle of 2017. Needless to say, this ultimate test of OTIS, the cryogenic portion of JWST will be crucial in verifying the end-to-end performance of JWST. A repeat of this test would not only be expensive, but would delay the launch schedule (currently October 2018). Therefore a series of checkouts and verifications of the chamber and ground support equipment were planned and carried out between 2012 and 2016. This paper will provide a top-level summary of those tests, trades in coming up with the test plan, as well as some details of individual issues that were encountered and resolved in the course of testing.

  18. Final Test at the Surface of the ATLAS Endcap Muon Trigger Chamber Electronics

    CERN Document Server

    Kubota, T; Kanaya, N; Kawamoto, T; Kobayashi, T; Kuwabara, T; Nomoto, H; Sakamoto, H; Yamaguchi, T; Fukunaga, C; Ikeno, M; Iwasaki, H; Nagano, K; Nozaki, M; Sasaki, O; Tanaka, S; Yasu, Y; Hasegawa, Y; Oshita, H; Takeshita, T; Nomachi, M; Sugaya, Y; Sugimoto, T; Okumura, Y; Takahashi, Y; Tomoto, M; Kadosaka, T; Kawagoe, K; Kiyamura, H; Kurashige, H; Niwa, T; Ochi, A; Omachi, C; Takeda, H; Lifshitz, R; Lupu, N; Bressler, S; Tarem, S; Kajomovitz, E; Ben Ami, S; Bahat Treidel, O; Benhammou, Ya; Etzion, E; Lellouch, D; Levinson, L; Mikenberg, G; Roich, A

    2007-01-01

    For the detector commissioning planned in 2007, sector assembly of the ATLAS muon-endcap trigger chambers and final test at the surface for the assembled electronics are being done in CERN and almost completed. For the test, we built up the Data Acquisition (DAQ) system using test pulse of two types and cosmic rays in order to check functionality of the various aspects of the electronics mounted on a sector. So far, 99% of all 320,000 channels have been tested and most of them were installed into the ATLAS cavern. In this presentation, we will describe the DAQ systems and mass-test procedure in detail, and report the result of electronics test with some actual experiences

  19. In-situ high field strength testing using a transportable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2008-01-01

    A reverberation chamber can create very high fieldstrength with moderate input power. Existing chambers are making use of a paddle wheel to change the resonant modes in the chamber. In the case of a stepper motor, the field is stable for some time, and this type of reverberation chamber is called

  20. In-situ high field strength testing using a transportable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2008-01-01

    A reverberation chamber can create very high field strength with moderate input power. Existing chambers are making use of a paddle wheel to change the resonant modes in the chamber. In the case of a stepper motor, the field is stable for some time, and this type of reverberation chamber is called

  1. A SIMPLE Bubble Chamber for Dark Matter Searches: Testing and Development

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, A.R.; Fernandes, A.C.; Marques, J.G.; Kling, A. [C2TN, Instituto Superior Tecnico, Universidade de Lisboa, E.N. 10 - km 139.7, 2695-066 Bobadela, LRS (Portugal); Felizardo, M.; Girard, T.A. [Centro de Fisica Nuclear, Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003, Lisbon (Portugal); Lazaro, I. [Laboratoire Souterrain a Bas Bruit, UMS 3538 UNS/UAPV/CNRS, 84400 Rustrel-Pays d' Apt (France); Puibasset, J. [Centre de Recherche sur la Matiere Divisee CNRS et Universite d' Orleans, 45071 Orleans, 02 (France)

    2015-07-01

    SIMPLE (Superheated Instrument for Massive Particle Experiments) is one of only three experiments worldwide in search of evidence of astroparticle dark matter (WIMPs) using halocarbon-loaded superheated liquid (SHL) detectors. The 2012 Phase II SIMPLE measurements yielded the most restrictive exclusion contour in the spin-dependent (SD) sector of WIMP-proton interactions from a direct search experiment at the time, overlapping for the first time results previously obtained only indirectly [1]. In order to remain competitive with other experiments in the field, the next phase measurement requires larger exposure over shorter observation times with significantly improved neutron shielding. To increase exposure, SIMPLE plans, as a first step, to replace its superheated droplet detectors (SDDs), each containing an active mass of about 15 g of halocarbon, with bubble chambers capable of holding up to 20 kg of active halocarbon mass. We report on the development of the first 1 kg halocarbon SIMPLE bubble chamber prototype, including chamber recompression system design and testing and initial acoustic detection of bubble formation. (authors)

  2. Validation of the Read Out Electronics for the CMS Muon Drift Chambers at Tests Beam in CERN/GIF

    CERN Document Server

    Fernández, C; Fouz-Iglesias, M C; Marin, J; Oller, J C; Willmott, C

    2002-01-01

    Part of the readout system for the CMS muon drift chambers has been tested in test beams at CERN/GIF. Read Out Board (ROB) and HPTD have been validated with signals from a real muon beam, with an structure and flux similar to LHC operating conditions and using one of the chambers produced in CIEMAT already located in the test beam area under normal gas and voltage conditions. (Author) 5 refs.

  3. Construction and test of high precision drift-tube (sMDT) chambers for the ATLAS muon spectrometer

    CERN Document Server

    Nowak, Sebastian; Kroha, Hubert; Schwegler, Philipp; Sforza, Federico

    2014-01-01

    For the upgrade of the ATLAS muon spectrometer in March 2014 new muon tracking chambers (sMDT) with drift-tubes of 15 mm diameter, half of the value of the standard ATLAS Monitored Drift-Tubes (MDT) chambers, and 10~$\\mu$m positioning accuracy of the sense wires have been constructed. The new chambers are designed to be fully compatible with the present ATLAS services but, with respect to the previously installed ATLAS MDT chambers, they are assembled in a more compact geometry and they deploy two additional tube layers that provide redundant rack information. The chambers are composed of 8 layers of in total 624 aluminium drift-tubes. The assembly of a chamber is completed within a week. A semi-automatized production line is used for the assembly of the drift-tubes prior to the chamber assembly. The production procedures and the quality control tests of the single components and of the complete chambers will be discussed. The wire position in the completed chambers have been measured by using a coordinate me...

  4. ATS 6 EMI field measurements techniques and results. [anechoic chamber scale model testing

    Science.gov (United States)

    Afifi, M. S.; Keiser, B. E.

    1974-01-01

    At the present time 'Applications Technology Satellite (ATS)-6' is the world's largest communication satellite. It handles telecommunications in the frequency range of 40 - 30,000 MHz. Power levels on board the spacecraft range from -110 dBm to 52.5 dBw. Consequently considerable care was required in the design and test of this spacecraft, in order to provide assurances that the spacecraft would perform properly in its own RF environments. The testing was performed first by placing the earth viewing module (EVM) in a specially constructed 'small' anechoic chamber with an overhead parabolic reflector section, of 8' in diameter, instead of the 30' reflector of the full scale design. The near field analysis of this paper proves that this test configuration leads to a desirable overtest for the spacecraft. The test requirements, procedure and results are also explained.

  5. Determination of radon exhalation from construction materials using VOC emission test chambers.

    Science.gov (United States)

    Richter, M; Jann, O; Kemski, J; Schneider, U; Krocker, C; Hoffmann, B

    2013-10-01

    The inhalation of (222) Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available measuring devices in combination with VOC emission test chambers. Five materials - two types of clay brick, clinker brick, light-weight concrete brick, and honeycomb brick - generally used for wall constructions were used for the experiments. Their contribution to real room concentrations was estimated by applying room model parameters given in ISO 16000-9, RP 112, and AgBB. This knowledge can be relevant, if for instance indoor radon concentration is limited by law. The test set-up used here is well suited for application in test laboratories dealing with VOC emission testing. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Preparation of a Frozen Regolith Simulant Bed for ISRU Component Testing in a Vacuum Chamber

    Science.gov (United States)

    Klenhenz, Julie; Linne, Diane

    2013-01-01

    In-Situ Resource Utilization (ISRU) systems and components have undergone extensive laboratory and field tests to expose hardware to relevant soil environments. The next step is to combine these soil environments with relevant pressure and temperature conditions. Previous testing has demonstrated how to incorporate large bins of unconsolidated lunar regolith into sufficiently sized vacuum chambers. In order to create appropriate depth dependent soil characteristics that are needed to test drilling operations for the lunar surface, the regolith simulant bed must by properly compacted and frozen. While small cryogenic simulant beds have been created for laboratory tests, this scale effort will allow testing of a full 1m drill which has been developed for a potential lunar prospector mission. Compacted bulk densities were measured at various moisture contents for GRC-3 and Chenobi regolith simulants. Vibrational compaction methods were compared with the previously used hammer compaction, or "Proctor", method. All testing was done per ASTM standard methods. A full 6.13 m3 simulant bed with 6 percent moisture by weight was prepared, compacted in layers, and frozen in a commercial freezer. Temperature and desiccation data was collected to determine logistics for preparation and transport of the simulant bed for thermal vacuum testing. Once in the vacuum facility, the simulant bed will be cryogenically frozen with liquid nitrogen. These cryogenic vacuum tests are underway, but results will not be included in this manuscript.

  7. Data from one test "Semi-Volatile Organic Compound Small Chamber for bis (2-Ethylhexyl) phthalate in Vinyl Flooring Test 2"

    Science.gov (United States)

    This data was generated from a small chamber bis(2-ethylhexyl) phthalate (DEHP) emission test. It was to participate an interaboratory study of DEHP emissions from vinyl flooring in a SVOC emission chamber organized by Virginia Polytechnic Institute and State University (VT).

  8. A facility for the test of large area muon chambers at high rates

    CERN Document Server

    Agosteo, S; Belli, G; Bonifas, A; Carabelli, V; Gatignon, L; Hessey, N P; Maggi, M; Peigneux, J P; Reithler, H; Silari, Marco; Vitulo, P; Wegner, M

    2000-01-01

    Operation of large area muon detectors at the future Large Hadron Collider (LHC) will be characterized by large sustained hit rates over the whole area, reaching the range of kHz/\\scm. We describe a dedicated test zone built at CERN to test the performance and the aging of the muon chambers currently under development. A radioactive source delivers photons causing the sustained rate of random hits, while a narrow beam of high energy muons is used to directly calibrate the detector performance. A system of remotely controlled lead filters serves to vary the rate of photons over four orders of magnitude, to allow the study of performance as a function of rate.

  9. Testing of the abiotic degradation of chemicals in the atmosphere: the smog chamber approach

    Energy Technology Data Exchange (ETDEWEB)

    Kloepffer, W.H.; Haag, F.; Kohl, E.G.; Frank, R.

    1988-06-01

    Methods for measuring the hydroxyl-, ozone-, and direct photochemical reactivity of a substance in one specially designed medium size smog chamber are described. Rate coefficients for the reaction of OH with n-hexane, n-heptane, ethene, ethyne, chloroform, trichloroethene, methanol, 2-propanol, benzene, o-xylene, 1,4-dichlorobenzene, 1,2,4-trichlorobenzene, p-chloroaniline, naphthalene, acenaphthene, 1,4-dichloronaphthalene, biphenyl, and fluorenone are given and discussed. An upper limit of 5 X 10(-13) cm3/sec is given for the sum penta- and hexa-chlorobiphenyls (PCB). Rate coefficients for the ozone reaction are given for beta-pinene, limonene, delta 3-carene, cineol, vinyl chloride and 1,3-butadiene. In cases where the literature data are available for comparison, the rate coefficients (kappa OH and kappa O3) reported here compare favorably with the best data reported. The direct photochemical reactivity has been shown to be measurable if the chamber is cleaned carefully. Preliminary results on benzophenone are reported. The methods described here, except that of direct photochemical reactivity, are in agreement with those proposed to OECD. Moreover, part of the Draft OECD Test Guideline (Berlin, 1987) on Photochemical-Oxidative Degradation in the Atmosphere is based on work described here and on closely related work in other laboratories.

  10. A Push-Pull Test to Measure Volatilization Fluxes of Organic Pollutants without Flux Chambers

    Science.gov (United States)

    Reid, M. C.; Jaffe, P. R.

    2011-12-01

    Volatilization of organic contaminants is a potentially significant removal mechanism from wetlands, but field measurements are scarce and the physiochemical controls on volatilization from wetland soils remain poorly understood. It has been established that volatilization rates of certain pollutants are enhanced by vegetation and are strongly correlated with evapotranspiration (ET). These observations rely on flux chambers measurements, which are characterized by significant uncertainty due the chamber's effects on the meteorological variables around the plant and consequent impact on the biophysical processes governing ET and plant uptake of soil contaminants. Here we present data from a mesocosm study using a modified single-well push-pull test to measure in-situ volatilization rates from inundated soils vegetated with the wetland macrophytes Scirpus acutus and Typha latifolia, as well as from unplanted soil. This new method uses a test solution containing the volatile tracers sulfur hexafluoride (SF6), helium (He), and dichlorodifluoromethane (CFC-12) to estimate first-order volatilization rates and examine the relationship between physiochemical properties and volatilization rates. The test also yields an estimate for the volume of subsurface gas bubbles, which is used to derive a retardation factor for the effect of interphase partitioning on the estimation of kinetic parameters. We evaluate models to partition observed fluxes into different pathways for plant-mediated volatilization: transpirational uptake and consequent volatilization, and gas-phase diffusion through porous root aerenchyma. Those models are then used to scale tracer-derived volatilization fluxes to priority organic pollutants including benzene, trichloroethylene, and vinyl chloride. We also discuss the implementation of this method at field scales to estimate volatilization as a component of phytoremediation applications.

  11. Recent Advances on OTA Testing for 5G Antenna Systems in Multi-probe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Fan, Wei; Pedersen, Gert F.; Kyösti, Pekka

    2017-01-01

    Over-the-air (OTA) testing is seen as an essential method for evaluating 5G antenna systems, since conventional cable testing are no longer applicable. In the paper, we discussed the similarities and discrepancies of OTA testing in the multiprobe anechoic chamber (MPAC) setups for 4G user equipment...

  12. Construction and test of new precision drift-tube chambers for the ATLAS muon spectrometer

    Science.gov (United States)

    Kroha, H.; Kortner, O.; Schmidt-Sommerfeld, K.; Takasugi, E.

    2017-02-01

    ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 μm have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new RPC trigger chambers for replacement of the inner layer of the barrel muon spectrometer are in progress.

  13. Evaluation of ozone generation and indoor organic compounds removal by air cleaners based on chamber tests

    Science.gov (United States)

    Yu, Kuo-Pin; Lee, Grace Whei-May; Hsieh, Ching-Pei; Lin, Chi-Chi

    2011-01-01

    Ozone can cause many health problems, including exacerbation of asthma, throat irritation, cough, chest ache, shortness of breath, and respiratory infections. Air cleaners are one of the sources of indoor ozone, and thus the evaluation of ozone generated by air cleaners is desired significant issue. Most evaluation methods proposed are based on chamber tests. However, the adsorption and desorption of ozone on the wall of test chamber and the deposition of ozone resulted from the surface reaction can influence the evaluation results. In this study, we developed a mass balance model that took the adsorption, desorption and deposition of ozone into consideration to evaluate the effective ozone emission rates of six selected air cleaners. The experiments were conducted in a stainless steel chamber with a volume of 11.3 m 3 at 25 °C and 60% relative humidity. The adsorption, desorption and deposition rate constants of ozone obtained by fitting the model to the experimental data were k a = 0.149 ± 0.052 m h -1, k d = 0.013 ± 0.007 h -1, and k r = 0.050 ± 0.020 h -1, respectively. The effective ozone emission rates of Air Cleaners No. 1, 2, and 3 ranged between 13,400-24,500 μg h -1, 7190-10,400 μg h -1, and 4880-6560 μg h -1, respectively, which were more stable than those of No.4, 5, and 6. The effective ozone emission rates of Air Cleaners No. 4, 5, and 6 increased with the time of operation which might be relevant to the decrease of ozone removal by the "aging" filter installed in these cleaners. The removal of toluene and formaldehyde by these six air cleaners were also evaluated and the clean air delivery rates (CADRs) of these two pollutants ranged from non-detectable to 0.42 ± 0.08 m 3 h -1, and from non-detectable to 0.75 ± 0.07 m 3 h -1, respectively. The CADRs showed an insignificant relationship with the effective ozone emission rates. Thus, the removal of toluene and formaldehyde might be resulted from the adsorption on the filters and the

  14. Electron beam test of an iron/gas calorimeter based on ceramic parallel plate chambers

    Energy Technology Data Exchange (ETDEWEB)

    Arefiev, A.; Bencze, Gy.L.; Bizzeti, A.; Choumilov, E.; Civinini, C; Dalla Santa, F.; D' Alessandro, R.; Ferrando, A.; Fouz, M.C.; Herve, A.; Iglesias, A.; Ivochkin, V.; Josa, M.I.; Maggi, F.; Malinin, A.; Meschini, M.; Pojidaev, V.; Radermacher, E.; Salicio, J.M.

    1995-07-01

    The baseline option for the very forward calorimetry in the CMS experiment is an iron/gas calorimeter based on parallel plate chambers. A small prototype module of such a calorimeter, has been tested using electrons of 5 to 100 GeV/c momentum with various high voltages and two gases: CO2 (100%) and CF4/CO2 (80/20), at atmospheric pressure. The collected charge has been measured as a function of the high voltage and of the electron energy. The energy resolution has also been measured. Comparisons have been made with Monte-Carlo predictions. Agreement between data an simulation allows to make and estimation of the expected performance of a full size calorimeter. (Author) 23 refs.

  15. Final results from an extensive ageing test of bakelite Resistive Plate Chambers

    CERN Document Server

    Carboni, G; De Capua, S; Dominici, Daniele; Messi, R; Passaleva, G; Santovetti, E; Veltri, M

    2004-01-01

    We present the final results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two bakelite Resistive Plate Chambers (RPC) detectors. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistivity rho of the two RPC prototypes over 3 years. We observed a large spontaneous increase of rho with time, from the initial value of about 10**1**0 Omega cm to more than 200 multiplied by 10**1**0 Omega cm. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm**2 to less than 200 Hz/cm**2, was observed; the reversibility of the process, using a humid gas mixture, has also been studied. We also present a study of the effects of humidity on the bakelite resistivity using two 10 multiplied by 10 cm**2 bakelite samples.

  16. Venus Pressure Chamber: A Small Testing Facility Available to the Community

    Science.gov (United States)

    Johnson, Natasha M.; Wegel, D. C.

    2011-01-01

    Venus is an inhospitable planet where the surface mean. temperature is approximately 740K and the global mean pressure is approximately 95 bars. The atmosphere is comprised mostly of CO2 (approximately 96.5%) and N2 (approximately3.5%) with trace amounts of CO and other reactive gases. Although Venus is very similar in size and mass with the Earth and is Earth's nearest planetary neighbor, it has not received many visitors from Earth, especially those that can land on the surface. The challenge most often cited for this scarcity of surface probes is the workability/survivability of instruments and equipment in Venus' harsh environment. In order to overcome this obstacle, a small pressure chamber has been acquired for use by the scientific community. It is housed at Goddard Space. Flight Center in Maryland and is available to the community for testing of small flight components, instruments and short-term experiments that require high temperatures and pressures.

  17. Construction and Test of New Precision Drift-Tube Chambers for the ATLAS Muon Spectrometer

    CERN Document Server

    INSPIRE-00218480

    2017-02-11

    ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 ?micons have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new R...

  18. Testing of a Device for Positioning Measuring Microphones in Anechoic and Reverberation Chambers

    National Research Council Canada - National Science Library

    Felis, Józef; Flach, Artur; Kamisiński, Tadeusz

    2012-01-01

    This paper presents a mechanical positioning system for a measuring microphone designed for acoustic studies in anechoic and reverberation chambers at the Department of Mechanics and Vibroacoustics, AGH...

  19. Electromagnetic compatibility (EMC) standard test chamber upgrade requirements for spacecraft design verification tests

    Science.gov (United States)

    Dyer, Edward F.

    1992-01-01

    In view of the serious performance deficiencies inherent in conventional modular and welded shielding EMC test enclosures, in which multipath reflections and resonant standing waves can damage flight hardware during RF susceptibility tests, NASA-Goddard has undertaken the modification of a 20 x 24 ft modular-shielded enclosure through installation of steel panels to which ferrite tiles will be mounted with epoxy. The internally reflected RF energy will thereby be absorbed, and exterior power-line noise will be reduced. Isolation of power-line filters and control of 60-Hz ground connections will also be undertaken in the course of upgrading.

  20. Development and Hot-fire Testing of Additively Manufactured Copper Combustion Chambers for Liquid Rocket Engine Applications

    Science.gov (United States)

    Gradl, Paul R.; Greene, Sandy Elam; Protz, Christopher S.; Ellis, David L.; Lerch, Bradley A.; Locci, Ivan E.

    2017-01-01

    NASA and industry partners are working towards fabrication process development to reduce costs and schedules associated with manufacturing liquid rocket engine components with the goal of reducing overall mission costs. One such technique being evaluated is powder-bed fusion or selective laser melting (SLM), commonly referred to as additive manufacturing (AM). The NASA Low Cost Upper Stage Propulsion (LCUSP) program was designed to develop processes and material characterization for GRCop-84 (a NASA Glenn Research Center-developed copper, chrome, niobium alloy) commensurate with powder-bed AM, evaluate bimetallic deposition, and complete testing of a full scale combustion chamber. As part of this development, the process has been transferred to industry partners to enable a long-term supply chain of monolithic copper combustion chambers. To advance the processes further and allow for optimization with multiple materials, NASA is also investigating the feasibility of bimetallic AM chambers. In addition to the LCUSP program, NASA has completed a series of development programs and hot-fire tests to demonstrate SLM GRCop-84 and other AM techniques. NASA's efforts include a 4K lbf thrust liquid oxygen/methane (LOX/CH4) combustion chamber and subscale thrust chambers for 1.2K lbf LOX/hydrogen (H2) applications that have been designed and fabricated with SLM GRCop-84. The same technologies for these lower thrust applications are being applied to 25-35K lbf main combustion chamber (MCC) designs. This paper describes the design, development, manufacturing and testing of these numerous combustion chambers, and the associated lessons learned throughout their design and development processes.

  1. Biological monitoring of isocyanates and related amines. III. Test chamber exposure of humans to toluene diisocyanate.

    Science.gov (United States)

    Skarping, G; Brorson, T; Sangö, C

    1991-01-01

    Five men were exposed to toluene diisocyanate (TDI) atmospheres for 7.5 h. The TDI atmospheres were generated by a gas-phase permeation method, and the exposures were performed in an 8-m3 stainless-steel test chamber. The mean air concentration of TDI was ca. 40 micrograms/m3, which corresponds to the threshold limit value (TLV) of Sweden. The inhaled doses of 2,4- and 2,6-TDI were ca. 120 micrograms. TDI in the test chamber air was determined by an HPLC method using the 9-(N-methylaminomethyl)-anthracene reagent and by a continuous-monitoring filter-tape instrument. After hydrolysis of plasma and urine, the related amines, 2,4- and 2,6-toluenediamine 2,4-, and 2,6-TDA), were determined as pentafluoropropionic anhydride (PFPA) derivatives by capillary gas-chromatography using selected ion monitoring (SIM) in the electron-impact mode. The urinary elimination of the TDAs showed a possible biphasic pattern, with rapid first phases for 2,4-TDA (mean t1/2 for the concentration in urine, 1.9 h) and for 2,6-TDA (mean t1/2 for the concentration in urine, 1.6 h). The cumulative amount of 2,4-TDA excreted in urine within 28 h ranged from 8% to 14% of the estimated dose of 2,4-TDI, and the cumulative amount of 2,6-TDA in urine ranged from 14% to 18% of the 2,6-TDI dose. The average urinary level of 2,4-TDA was 5 micrograms/l in the 6 to 8-h sample (range 2.8-9.6 micrograms/l), and the corresponding value for 2,6-TDA was 8.6 micrograms/l (range, 5.6-16.6 micrograms/l). Biological monitoring of exposure to 2,4- and 2,6-TDI by analysis of 2,4- and 2,6-TDA in urine is feasible.

  2. Testing an ionization chamber with gaseous samples and measurements of the (n, alpha) reaction cross sections

    CERN Document Server

    Gledenov, Yu M; Salatskii, V I; Sedyshev, P V; Andrzejewski, J; Szalanski, P

    1999-01-01

    A new ionization chamber with gaseous samples (GIC) has been designed and tested on the thermal and resonance neutron beams of FLNP's neutron sources. The exposed gas volume serves as a target for neutrons. The obtained thermal cross sections for the sup 1 sup 7 O(n, alpha) sup 1 sup 4 C, sup 2 sup 1 Ne(n, alpha) sup 1 sup 8 O and sup 3 sup 6 Ar(n, alpha) sup 3 sup 3 S reactions are (233+-12) mb, (0.18+-0.09) mb and (5.43+-0.27) mb, respectively. These measurements have been performed on a pure beam of thermal neutrons from the high flux reactor IBR-2; and they demonstrated high efficiency and reliability of the method. Compared to samples on substrates, the application of gaseous samples makes the beam background essentially lower, and what is more important, the background component is totally absent due to the absence of Li and B microimpurities in gaseous samples while they do present in the samples on substrates. The method is also applicable to measurements with resonance neutrons. The recovery capabili...

  3. Cosmic ray test system for the ATLAS thin gap chamber modules at KOBE

    CERN Document Server

    Suigmoto, T; Arataki, Y; Bando, T; Homma, Y; Ichimiya, R; Ikeno, M; Ishii, K; Ishino, M; Iwasaki, H; Kurashige, H; Mima, T; Miyazaki, Y; Nakagawa, Y; Nakaune, Y; Nozaki, M; Ohshita, H; Okumura, K; Sasaki, O; Suzuki, R; Takeda, H; Takeshita, T; Tanaka, S; Uda, J; Yokoyama, C

    2004-01-01

    Thin gap chamber modules giving function of forward muon trigger to the ATLAS detector in the LHC experiment have been constructed at High Energy Research Organization (KEK) in Japan and their performances have been checked at Kobe University. A large-scale test system specially designed for measuring uniformity of the detection efficiencies and the timing resolution of 8 TGC modules at the same time was successfully operated. Each TGC module had 72 anode wire channels and 64 cathode strip channels (in total 1088 readout channels for 8 modules). Drift tubes consisted of 12 layers (total 428 tubes), between which the TGC modules are put, determined trajectories of cosmic rays. Hit pattern and timing of all detector signals (Trigger counter. Drift tubes and TGCs) were measured by using VME modules. In regular data acquisition situation, i.e. about effective 19 Hz trigger rate from scintillation counters and 73% tracking efficiency by the drift tubes, the detection efficiency of each layer by 5 mm * 5 mm region ...

  4. Suitability of small environmental chambers to test the emission of biocides from treated materials into the air

    Science.gov (United States)

    Horn, Wolfgang; Jann, Oliver; Wilke, Olaf

    Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100-200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SER a's). The SER a's (μg m -2 h -1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SER a stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SER a's (μg m -2 h -1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole.

  5. Conceptual design and issues of the laser inertial fusion test (LIFT) reactor—targets and chamber systems

    Science.gov (United States)

    Norimatsu, T.; Kozaki, Y.; Shiraga, H.; Fujita, H.; Okano, K.; Members of LIFT Design Team

    2017-11-01

    We present the conceptual design of an experimental laser fusion plant known as the laser inertial fusion test (LIFT) reactor. The conceptual design aims at technically connecting a single-shot experiment and a commercial power plant. The LIFT reactor is designed on a three-phase scheme, where each phase has specific goals and the dedicated chambers of each phase are driven by the same laser. Technical issues related to the chamber technology including radiation safety to repeat burst mode operation are discussed in this paper.

  6. Construction and Test of Muon Drift Tube Chambers for High Counting Rates

    CERN Document Server

    Schwegler, Philipp; Dubbert, Jörg

    2010-01-01

    Since the start of operation of the Large Hadron Collider (LHC) at CERN on 20 November 2009, the instantaneous luminosity is steadily increasing. The muon spectrometer of the ATLAS detector at the LHC is instrumented with trigger and precision tracking chambers in a toroidal magnetic field. Monitored Drift-Tube (MDT) chambers are employed as precision tracking chambers, complemented by Cathode Strip Chambers (CSC) in the very forward region where the background counting rate due to neutrons and γ's produced in shielding material and detector components is too high for the MDT chambers. After several upgrades of the CERN accelerator system over the coming decade, the instantaneous luminosity is expected to be raised to about five times the LHC design luminosity. This necessitates replacement of the muon chambers in the regions with the highest background radiation rates in the so-called Small Wheels, which constitute the innermost layers of the muon spectrometer end-caps, by new detectors with higher rate cap...

  7. Design and performance of the vacuum chambers for the undulator of the VUV FEL at the TESLA test facility at DESY

    CERN Document Server

    Hahn, U; Pflüger, J; Rüter, M; Schmidt, G; Trakhtenberg, E

    2000-01-01

    Three vacuum chambers for the VUV SASE FEL undulator sections at the TESLA Test Facility (TTF) were designed, built, tested and installed. Each chamber is 4.5 m long and of 11.5 mm thick. The inner diameter of the beam pipe is 9.5 mm. The rectangular chamber profile with a width of 128 mm is used to integrate beam position monitors and steerers. This is needed to provide a good overlap between the electron and the photon beam over the entire undulator length. The chambers are built in an aluminum extrusion technology developed for the insertion device vacuum chambers of the Advanced Photon Source. After manufacturing, special processing was performed to reach low outgassing rates (<1x10 sup - sup 1 sup 1 mbar centre dot l/s centre dot cm sup 2) and particle-free chambers. Mounting of the chambers at TTF were performed under clean room conditions better class 100.

  8. Comparison of measurements of the characteristics of directional microphone hearing aids in an IAC test room and an anechoic chamber.

    Science.gov (United States)

    Brey, R H; Caustin, E I; McPherson, J H

    1977-01-01

    The purpose of this study was to assess the possibility of measuring directional microphone hearing aids (DMHAs) using standard hearing aid test instruments in a sound field environment. The use of DMHAs is increasing and research has shown that under certain difficult listening situations, superior results are obtained by hearing impaired individuals with directional versus omnidirectional microphone arrangements. However, valid electroacoustic evaluation of the DMHAs cannot be accomplished using the conventional hearing aid test box. The ideal environment for such evaluations is an anechoic chamber, a facility not found in most audiological clinics. Results show that if the proper precautions are observed, the electroacoustic characteristics of DMHAs can be measured in a sound field environment using conventional hearing aid test instrumentation. Validation of this procedure was carried out by comparing sound field results with those obtained in an anechoic chamber.

  9. A Test Model in a RF Anechoic Chamber for the Application of Wi-Fi Communication in Korean Operating NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sik; Kim, Min Seok; Ryu, Ho Sun; Ye, Song Hae; Lee, Gwang Dae [KHNP, Daejeon (Korea, Republic of)

    2014-08-15

    The objective of this study is to make a test model and confirm its effectiveness in a radio frequency (RF) anechoic chamber before conducting a field test in Korean operating NPPs for use of Wi-Fi communication technology. This paper is focused on electromagnetic/radio-frequency interference (EMI/RFI) issue and discusses a methodology and its test result for overcoming that issue. Whenever wireless communication is performed between an access point (AP) and a smart phone, EMI/RFI problem always happens around those devices. It is necessary to decide how many wireless devices local workers will use and select what facilities and systems to protect from EMI/RFI, which are so-called EMI/RFI sensitive equipment. The number of wireless devices was decided as many as possible in the area where those devices could be used, and some sensitive equipment that shall not malfunction under electromagnetic environment were chosen. The test bed which considered above mentioned conditions was constructed and an experiment was carried out inside a radio-frequency anechoic chamber. Comparing with the allowable operating envelopes for electromagnetic level from RG-1.180, each maximum level of the test results acquired from a RF anechoic chamber is not over the limit even in case of considering the maximum local workers' usage. This result shows that it is highly likely that Wi-Fi communication can be used without any problem if sensitive equipment has observed the electromagnetic susceptibility limit of RG-1.180.

  10. Precision tracking with small-strip Thin Gap Chamber (sTGC): from Test Beam to ATLAS NSW Upgrade

    CERN Document Server

    Benhammou, Yan

    2014-01-01

    The forthcoming luminosity upgrade of LHC to super - LHC (sLHC) will increase the e xpected background rate in the forward region of the ATLAS Muon Spectrometer by approximately a factor of five. Some of the present Muon Spectrometer components will fail to cope with these high rates and will have to be replaced. A development of the Th in Gap Chambers (TGC) has been tested during the last four years. The results of these tests , presented here, showed that the small strip Thin Gap Chambers (sTGC) provide a fast trigger and high precision muon tracking under sLHC conditions. In 2012, sTGC technology has been accepted as a part of the New Small Wheel (NSW).

  11. Construction of a Thermal Vacuum Chamber for Environment Test of Triple CubeSat Mission TRIO-CINEMA

    Directory of Open Access Journals (Sweden)

    Jeheon Jeon

    2013-09-01

    Full Text Available TRiplet Ionospheric Observatory-CubeSat for Ion, Neutron, Electron & MAgnetic fields (TRIO-CINEMA is a CubeSat with 3.14 kg in weight and 3-U (10 × 10 × 30 cm in size, jointly developed by Kyung Hee University and UC Berkeley to measure magnetic fields of near Earth space and detect plasma particles. When a satellite is launched into orbit, it encounters ultrahigh vacuum and extreme temperature. To verify the operation and survivability of the satellite in such an extreme space environment, experimental tests are conducted on the ground using thermal vacuum chamber. This paper describes the temperature control device and monitoring system suitable for CubeSat test environment using the thermal vacuum chamber of the School of Space Research, Kyung Hee University. To build the chamber, we use a general purpose thermal analysis program and NX 6.0 TMG program. We carry out thermal vacuum tests on the two flight models developed by Kyung Hee University based on the thermal model of the TRIO-CINEMA satellite. It is expected from this experiment that proper operation of the satellite in the space environment will be achieved.

  12. Construction and Initial Tests of the Time Projection Chamber at TRIUMF

    Science.gov (United States)

    Hargrove, C. K.; Mes, H.; Carter, A. L.; Hincks, E. P.; Kessler, D.; Beer, G. A.; Bryman, D.; Numao, T.; Olin, A.; Pearce, R. M.; Reeve, P.; Robertson, L. B.; Hasinoff, M.; Poutissou, J. M.; Macdonald, J. A.; Spuller, J.; Azuelos, G.; Depommier, P.; Martin, J. P.; Poutissou, R.; Anderson, H. L.; Wright, S. C.; McKee, R. J.; Blecher, M.; Gotow, K.

    1981-04-01

    We have constructed an apparatus to search for the lepton number violating decay of the muon μ-Z → e-Z. The apparatus is based on the Time Projection Chamber principle. The main advantages are a large solid angle simeq 60%, simple trigger, good energy resolution, particle identification and simplified electronics. The details of the apparatus are described and preliminary results are given.

  13. Burning carbon monoxide in the settling chamber of a hotshot wind tunnel for obtaining the CO2 test gas

    Science.gov (United States)

    Shumskii, V. V.; Yaroslavtsev, M. I.

    2016-03-01

    A method of formation and heating of CO2 as a test gas in the settling chamber of a hotshot wind tunnel is considered. To form and heat CO2, the chamber is filled with a source gas mixture of CO, O2, and CO2, and after initiation, these substances participate in an exothermic chemical reaction in accordance with the formula CO + 0.5 O2 + xCO2 = (1 + x)CO2. A stoichiometric ratio of the concentrations of carbon monoxide CO and oxygen is used. Variation of the number of moles x of ballast CO2 in the left part of the chemical formula allows changing the temperature of the resultant test gas in a wide range. Experiments in the IT-302M hotshot wind tunnel carried out at ITAM SB RAS have shown that a pressure increase during an isochoric process in the settling chamber due to the joint effect of heat released in the reaction CO + 0.5 O2 and an electric charge provides the completeness of CO combustion almost equal to unity. The time of reaction completion at its initiation by an electric arc is no more than several milliseconds.

  14. Exposure assessment method for products containing carbon nanotubes inside a test chamber with a Taber abrasion machine

    Science.gov (United States)

    Matsui, Yasuto; Nagaya, Taiki; Nobuyuki, Kato; Ishibashi, Tomonori; Yoneda, Minoru

    2017-06-01

    Polymer/carbon nanotube (CNT) composites exhibit distinguished properties, but more quantitative risk assessments on CNTs are necessary as research and development advances. One method to assess the exact risk is to evaluate the characteristics of nanoparticles generated from CNT composites during sanding or Taber abrasion tests. Some researchers have applied loads to CNT composites using Taber machines and analysed the particles using aerosol-measuring instruments and electron microscopes. However, employing aerosol-measuring instruments is challenging due to the small amount of generated particles. Additionally, the presence of abundant background nanoparticles in testing environments creates issues in quantitative measurements. Our research strives to develop an examination method to measure even very small amounts of nanoparticles generated by Taber abrasion. In this study, a Taber abrasion machine is miniaturised so that it fits inside a small chamber. A high-efficiency particulate air filter is attached to the chamber to eliminate background nanoparticles. Then CNT composites are abraded with the miniaturised Taber abrasion machine inside the chamber and the generated particles are analysed.

  15. Design of Refractory Metal Heat Pipe Life Test Environment Chamber, Cooling System, and Radio Frequency Heating System

    Science.gov (United States)

    Martin, J. J.; Bragg-Sitton, S. M.; Reid, R. S.; Stewart, E. T.; Davis, J. D.

    2011-01-01

    A series of 16 Mo-44.5%Re alloy/sodium heat pipes will be experimentally tested to examine heat pipe aging. To support this evaluation, an environmental test chamber and a number of auxiliary subsystems are required. These subsystems include radio frequency (RF) power supplies/inductive coils, recirculation water coolant loops, and chamber gas conditioning. The heat pipes will be grouped, based on like power and gas mixture requirements, into three clusters of five units each, configured in a pentagonal arrangement. The highest powered heat pipe will be tested separately. Test chamber atmospheric purity is targeted at <0.3 ppb oxygen at an approximate operating pressure of 76 torr (.1.5 psia), maintained by active purification (oxygen level is comparable to a 10(exp -6) torr environment). Treated water will be used in two independent cooling circuits to remove .85 kW. One circuit will service the RF hardware while the other will maintain the heat pipe calorimetry. Initial procedures for the startup and operation of support systems have been identified. Each of these subsystems is outfitted with a variety of instrumentation, integrated with distributed real-time controllers and computers. A local area network provides communication between all devices. This data and control network continuously monitors the health of the test hardware, providing warning indicators followed by automatic shutdown should potentially damaging conditions develop. During hardware construction, a number of checkout tests.many making use of stainless steel prototype heat pipes that are already fabricated.will be required to verify operation.

  16. Flow Quality Surveys in the Settling Chamber of the NASA Glenn Icing Research Tunnel (2011 Tests)

    Science.gov (United States)

    Steen, Laura E.; VanZante, Judith Foss; Broeren, Andy P.; Kubiak, Mark J.

    2014-01-01

    In 2011, the heat exchanger and refrigeration plant for NASA Glenn Research Centers Icing Research Tunnel (IRT) were upgraded. Flow quality surveys were performed in the settling chamber of the IRT in order to understand the effect that the new heat exchanger had on the flow quality upstream of the spray bars. Measurements were made of the total pressure, static pressure, total temperature, airspeed, and flow angle (pitch and yaw). These measurements were directly compared to measurements taken in 2000, after the previous heat exchanger was installed. In general, the flow quality appears to have improved with the new heat exchanger.

  17. Dynamic testing of thin-walled composite box beams in a vacuum chamber

    Science.gov (United States)

    Chandra, Ramesh; Chopra, Inderjit

    1989-01-01

    Vibration characteristics of thin-walled composite box beams are measured in a rotating environment in a 10-ft diameter vacuum chamber. Symmetric and antisymmetric layup beams are fabricated out of graphite/epoxy prepreg material using an autoclave molding technique. These are excited using piezoelectric ceramic elements and responses are measured using strain gages and accelerometers. First three natural modes are identified using spectrum analyzer over a range of rotational speeds up to 1000 rpm. Measured frequencies and mode shapes (displacement as well as strain) are correlated satisfactorily with calculated finite element results.

  18. Michigan ATLAS MDT Chamber Mass Production

    CERN Document Server

    Diehl, E; Levin, D; McKee, S; Neal, H; Schick, H; Tarle, G; Thun, R; Weaverdyck, C; Xu, Q; Zhao, Z; Zhou, B

    2001-01-01

    This paper describes the ATLAS MDT precision muon chamber construction at the University of Michigan. The chamber assembly facilities, the jigging set up, alignment procedures, and other measurements necessary for chamber assembly are described. The chamber quality assurance monitoring procedures and data for the first year mass production are presented. The chamber gas system assembly facilities, and the chamber leak test procedure together with data also reported. The chamber production database, which monitors chamber production, is also discussed.

  19. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  20. Modernization of NASA's Johnson Space Center Chamber: A Payload Transport Rail System to Support Cryogenic Vacuum Optical Testing of the James Webb Space Telescope (JWST)

    Science.gov (United States)

    Garcia, Sam; Homan, Jonathan; Speed, John

    2016-01-01

    NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the "Great Observatories", scheduled for launch in 2018. It is directly responsible for the integration and test (I&T) program that will culminate in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describe the challenges of developing, integrating and modifying new payload rails capable of transporting payloads within the thermal vacuum chamber up to 65,000 pounds. Ambient and Cryogenic Operations required to configure for testing will be explained. Lastly review historical payload configurations stretching from the Apollo program era to current James Webb Space Telescope testing.

  1. DESIGN, FABRICATION, ASSEMBLY AND BENCH TESTING OF A TEXACO INFRARED RATIO PYROMETER SYSTEM FOR THE MEASUREMENT OF REACTION CHAMBER TEMPERATURE

    Energy Technology Data Exchange (ETDEWEB)

    Tom Leininger

    2001-03-31

    Reliable measurement of gasifier reaction chamber temperature is important for the proper operation of slagging, entrained-flow gasification processes. Historically, thermocouples have been used as the main measurement technique, with the temperature inferred from syngas methane concentration being used as a backup measurement. While these have been sufficient for plant operation in many cases, both techniques suffer from limitations. The response time of methane measurements is too slow to detect rapid upset conditions, and thermocouples are subject to long-term drift, as well as slag attack, which eventually leads to failure of the thermocouple. Texaco's Montebello Technology Center (MTC) has developed an infrared ratio pyrometer system for measuring gasifier reaction chamber temperature. This system has a faster response time than both methane and thermocouples, and has been demonstrated to provide reliable temperature measurements for longer periods of time when compared to thermocouples installed in the same MTC gasifier. In addition, the system can be applied to commercial gasifiers without any significant scale-up issues. The major equipment items, the purge system, and the safety shutdown system in a commercial plant are essentially identical to the prototypes at MTC. The desired result of this DOE program is ''a bench-scale prototype, either assembled or with critical components (laboratory) tested in a convincing manner.'' The prototype of the pyrometer system (including gasifier optical access port) that was designed, assembled and tested for this program, has had previous prototypes that have been built and successfully tested under actual coal and coke gasification conditions in three pilot units at MTC. It was the intent of the work performed under the auspices of this program to review and update the existing design, and to fabricate and bench test an updated system that can be field tested in one or more commercial gasifiers

  2. Ussing Chamber

    NARCIS (Netherlands)

    Westerhout, J.; Wortelboer, H.; Verhoeckx, K.

    2015-01-01

    The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are

  3. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  4. An overview of changes in pressure values of the middle ear using impedance audiometry among diver candidates in a hyperbaric chamber before and after a pressure test

    Science.gov (United States)

    Anoraga, J. S.; Bramantyo, B.; Bardosono, S.; Simanungkalit, S. H.; Basiruddin, J.

    2017-08-01

    Impedance audiometry is not yet routinely used in pressure tests, especially in Indonesia. Direct exposure to pressure in a hyperbaric chamber is sometimes without any assessment of the middle ear or the Eustachian tube function (ETF) of ventilation. Impedance audiometry examinations are important to assess ETF ventilation. This study determined the middle ear pressure value changes associated with the ETF (ventilation) of prospective divers. This study included 29 prospective divers aged 20-40 years without conductive hearing loss. All subjects underwent a modified diving impedance audiometry examination both before and after the pressure test in a double-lock hyperbaric chamber. Using the Toynbee maneuver, the values obtained for changes of pressure in the middle ear were significant before and after the pressure test in the right and left ears: p audiometry examination is necessary for the selection of candidate divers undergoing pressure tests within a hyperbaric chamber.

  5. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Article's Absorption during Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    Science.gov (United States)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    The exposure of a customers aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facilitys available acoustic power capability becomes maximized with the test-article installed during the actual test then the customers environment requirement may become compromised. In order to understand the risk of not achieving the customers in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Stations Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.

  6. Towards an ecological audiology: stereophonic listening chamber and acoustic environmental tests.

    Science.gov (United States)

    Borg, E; Wilson, M; Samuelsson, E

    1998-01-01

    An acoustic laboratory for reproduction of speech and acoustic environments is presented along with two sound field tests. Its design has been inspired by the LEDE (Living End Dead End) principle for construction of radio and music control rooms. The equipment and the 12 loudspeakers can simultaneously reproduce several stereophonic and monophonic recordings. The interesting feature is that the delayed first reflex in the LEDE room allows for a realistic perception of the recording room. A preliminary presentation of two newly developed tests for sound field listening is given. In DSIN. Directional Speech In Noise, the JFC (just follow conversation) threshold for continuous discourse is determined in 12 directions in quiet and in noise from +/- 60 degrees azimuth. In SEIT (Sound Environmental Identification Test), stereophonic acoustic environments are presented and the subject is asked to identify specific components and to characterize each environment as closely as possible. Results from tests with normal hearing subjects and examples of results with hearing impaired subjects are presented. The potential of the technique for use in aural rehabilitation, functional definition of auditory communication and quality assessment of hearing aids is discussed. It is pointed out that the term ecological audiology is suitable for describing the interaction between the communicating individual and the environment in a broad sense.

  7. Results of radiation test of the cathode front-end board for CMS endcap muon chambers

    CERN Document Server

    Breedon, R; Durkin, L S; Gilmore, J; Gu, J; Hauser, J; Holbrook, B; Kim, C L; Ling, T; Mey, M; Murray, P; Rush, C J; Santiard, Jean-Claude; Tripathi, M

    2001-01-01

    After a brief overview of the CMS EMU electronics system, results on radiation induced single event effects, total ionization dose and displacement effects will be reported. These results are obtained by irradiating the components on electronics boards with 63 MeV protons and 1 MeV neutrons. During the proton irradiation, the electronics board was fully under power, all components on the board were active and the data were read out in the same way as designed for CMS. No deterioration of analog performance for each of the three CMOS ASICs on the tested board was observed, up to a dose of 10 krad. Each of the tested FPGAs survived beyond the dose of 30 krad. No single event latch-up was detected for the CMOS ASICs up to a proton fluence of 2x10 sup 1 sup 2 cm sup - sup 2. Single Event Upsets (SEU) in FPGAs were detected and their cross-sections measured. SEU mitigation with triple module redundancy and voting was implemented and tested.

  8. Modernization of NASA's Johnson Space Center Chamber: A Liquid Nitrogen System to Support Cryogenic Vacuum Optical Testing of the James Webb Space Telescope (JWST)

    Science.gov (United States)

    Garcia, Sammy; Homan, Jonathan; Montz, Michael

    2016-01-01

    NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the “Great Observatories”, scheduled for launch in 2018. It is directly responsible for the integration and test (I&T) program that will culminate in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describes the steps performed in efforts to convert the existing the 60’s era Liquid Nitrogen System from a forced flow (pumped) process to a natural circulation (thermo-siphon) process. In addition, the paper will describe the dramatic conservation of liquid nitrogen to support the long duration thermal vacuum testing. Lastly, describe the simplistic and effective control system which results in zero to minimal human inputs during steady state conditions.

  9. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  11. Plasma Panel Detectors for MIP Detection for the SLHC and a Test Chamber Design

    CERN Document Server

    Ball, Robert; Etzion, Erez; Friedman, Peter S; Levin, Daniel S; Moshe, Meny Ben; Weaverdyck, Curtis; Zhou, Bing

    2010-01-01

    Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal and spatial resolution. We are investigating a new radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma television displays. The design and production of PDPs is supported by four decades of industrial development. Emerging from this television technology is the Plasma Panel Sensor (PPS), a novel variant of the micropattern radiation detector. The PPS is fundamentally an array of micro-Geiger plasma discharge cells operating in a non-ageing, hermetically sealed gas mixture . We report on the PPS development program, including design of a PPS Test Cell.

  12. The Mobile Chamber

    Science.gov (United States)

    Scharfstein, Gregory; Cox, Russell

    2012-01-01

    A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

  13. Corrosion resistance test based on electrochemical noise-limiting the number of long-lasting and costly climate chamber tests

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Veldman, D.; Gouwen, R.J.; Bende, E.E.; Eerenstein, W.

    2013-10-15

    Damp-heat testing of PV modules is a time-consuming process, taking months. The electrochemical noise (EcN) set-up is a fast, direct corrosion measurement of solar cells, whereby results can be obtained within one hour. EcN measurements are presented for several solar cell concepts and different environments. It correlates with damp-heat degradation involving corrosion, which is rather common in EVA-encapsulated crystalline Si modules. Furthermore, the EcN test can be done as an evaluation tool when probing alternative brands, formulations or processing for metallisation pastes and as a screening test for new batches of metallisation paste.

  14. The Use of the Molecular Adsorber Coating Technology to Mitigate Vacuum Chamber Contamination During Pathfinder Testing for the James Webb Space Telescope

    Science.gov (United States)

    Abraham, Nithin S.; Hasegawa, Mark M.; Wooldridge, Eve M.; Henderson-Nelson, Kelly A.

    2016-01-01

    As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

  15. The use of the Molecular Adsorber Coating technology to mitigate vacuum chamber contamination during Pathfinder testing for the James Webb Space Telescope

    Science.gov (United States)

    Abraham, Nithin S.; Hasegawa, Mark M.; Wooldridge, Eve M.; Henderson-Nelson, Kelly A.

    2016-09-01

    As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

  16. Calibration Chamber Testing

    Science.gov (United States)

    1992-01-30

    found that in the arificially CaCO3-cemented Monterey sand there is a kind of threshold content of cemented agent at which one achieves a maximum gain in... vision at ASCE, National Convention, St. Louis (Missouri), Oct. 1981 4. Canou, J., Hachem, M.El., Kattan, A. and Juran, I.,"Mini Piezocone(M-CPTU

  17. Mass transfer of PBDEs from plastic TV casing to indoor dust via three migration pathways — A test chamber investigation

    Energy Technology Data Exchange (ETDEWEB)

    Rauert, C.; Harrad, S., E-mail: S.J.Harrad@bham.ac.uk

    2015-12-01

    Polybrominated diphenyl ethers (PBDEs) are widely detected in humans with substantial exposure thought to occur in indoor environments and particularly via contact with indoor dust. Despite this, knowledge of how PBDEs migrate to indoor dust from products within which they are incorporated is scarce. This study utilises an in-house designed and built test chamber to investigate the relative significance of different mechanisms via which PBDEs transfer from source materials to dust, using a plastic TV casing treated with the Deca-BDE formulation as a model source. Experiments at both room temperature and 60 °C revealed no detectable transfer of PBDEs from the TV casing to dust via volatilisation and subsequent partitioning. In contrast, substantial transfer of PBDEs to dust was detected when the TV casing was abraded using a magnetic stirrer bar. Rapid and substantial PBDE transfer to dust was also observed in experiments in which dust was placed in direct contact with the source. Based on these experiments, we suggest that for higher molecular weight PBDEs like BDE-209; direct dust:source contact is the principal pathway via which source-to-dust transfer occurs. - Highlights: • Transfer from a TV casing to dust of high molecular weight PBDEs examined. • Direct source:dust contact effected rapid and most substantial transfer. • Substantial source:dust transfer also occurred via abrasion of source.

  18. Diagnostic value of scratch-chamber test, skin prick test, histamine release and specific IgE in birch-allergic patients with oral allergy syndrome to apple

    DEFF Research Database (Denmark)

    Osterballe, M; Scheller, R; Stahl Skov, P

    2003-01-01

    BACKGROUND: The aim of the study was to examine the diagnostic value of skin prick test (SPT), scratch-chamber test (SCT), histamine release (HR) and specific immunoglobulin E (IgE) in birch-allergic patients with oral allergy syndrome to apple. METHODS: Ten birch-allergic patients with oral...... allergy syndrome to apple and 10 control subjects were included. All were tested with SPT, SCT, HR and specific IgE [CAP, Pharmacia, Sweden and Magic Lite (ML), ALK-ABELLO, Denmark]. RESULTS: The SPT with apple, acetone extract of apple (A72) and commercial apple extract showed sensitivities of 0.80, 0.......90 and 0.10, respectively. The SCT with the same extracts showed sensitivities of 0.30, 0.50 and 0.20, respectively. The sensitivity of specific IgE to apple were 0.90 (CAP) and 0.10 (ML). The sensitivity of the HR test was 90% (A72), and 25% using the commercial extract. CONCLUSION: The SPT and HR test...

  19. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  20. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. Automated microbial metabolism laboratory. [design of advanced labeled release experiment based on single addition of soil and multiple sequential additions of media into test chambers

    Science.gov (United States)

    1974-01-01

    The design and rationale of an advanced labeled release experiment based on single addition of soil and multiple sequential additions of media into each of four test chambers are outlined. The feasibility for multiple addition tests was established and various details of the methodology were studied. The four chamber battery of tests include: (1) determination of the effect of various atmospheric gases and selection of that gas which produces an optimum response; (2) determination of the effect of incubation temperature and selection of the optimum temperature for performing Martian biochemical tests; (3) sterile soil is dosed with a battery of C-14 labeled substrates and subjected to experimental temperature range; and (4) determination of the possible inhibitory effects of water on Martian organisms is performed initially by dosing with 0.01 ml and 0.5 ml of medium, respectively. A series of specifically labeled substrates are then added to obtain patterns in metabolic 14CO2 (C-14)O2 evolution.

  4. The Low Temperature Chamber Testing of the Compression Ignition Engine and System of the Armoured Personnel Carrier (APC) M113A1.

    Science.gov (United States)

    1981-06-01

    warmup and immediately prior to engine cranking. On no occasion was there more than a five percent difference in specific gravities between battery...starter motor that would have been required to turn the transmission during cranking. The clutch, as can be seen in Table 1, was disengaged for all tests...except test 7. UNCLASSIFIED 6 UNCLASSIFIED The time between initial cold chamber compressor activation and vehicle starting was recorded as the "cold

  5. Around the laboratories: Dubna: Physics results and progress on bubble chamber techniques; Stanford (SLAC): Operation of a very rapid cycling bubble chamber; Daresbury: Photographs of visitors to the Laboratory; Argonne: Charge exchange injection tests into the ZGS in preparation for a proposed Booster

    CERN Multimedia

    1969-01-01

    Around the laboratories: Dubna: Physics results and progress on bubble chamber techniques; Stanford (SLAC): Operation of a very rapid cycling bubble chamber; Daresbury: Photographs of visitors to the Laboratory; Argonne: Charge exchange injection tests into the ZGS in preparation for a proposed Booster

  6. Tests of the data acquisition system and detector control system for the muon chambers of the CMS experiment at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Sowa, Michael Christian

    2009-02-27

    The Phys. Inst. III A of RWTH Aachen University is involved in the development, production and tests of the Drift Tube (DT) muon chambers for the barrel muon system of the CMS detector at the LHC at CERN (Geneva). The present thesis describes some test procedures which were developed and performed for the chamber local Data Acquisition (DAQ) system, as well as for parts of the Detector Control System (DCS). The test results were analyzed and discussed. Two main kinds of DAQ tests were done. On the one hand, to compare two different DAQ systems, the chamber signals were split and read out by both systems. This method allowed to validate them by demonstrating, that there were no relevant differences in the measured drift times, generated by the same muon event in the same chamber cells. On the other hand, after the systems were validated, the quality of the data was checked. For this purpose extensive noise studies were performed. The noise dependence on various parameters (threshold,HV) was investigated quantitatively. Also detailed studies on single cells, qualified as ''dead'' and ''noisy'' were done. For the DAQ tests a flexible hardware and software environment was needed. The organization and installation of the supplied electronics, as well as the software development was realized within the scope of this thesis. The DCS tests were focused on the local gas pressure read-out components, attached directly to the chamber: pressure sensor, manifolds and the pressure ADC (PADC). At first it was crucial to proof, that the calibration of the mentioned chamber components for the gas pressure measurement is valid. The sensor calibration data were checked and possible differences in their response to the same pressure were studied. The analysis of the results indicated that the sensor output depends also on the ambient temperature, a new experience which implied an additional pedestal measurement of the chamber gas pressure

  7. Production characteristics of lettuce Lactuca sativa L. in the frame of the first crop tests in the Higher Plant Chamber integrated into the MELiSSA Pilot Plant

    Science.gov (United States)

    Tikhomirova, Natalia; Lawson, Jamie; Stasiak, Michael; Dixon, Mike; Paille, Christel; Peiro, Enrique; Fossen, Arnaud; Godia, Francesc

    Micro-Ecological Life Support System Alternative (MELiSSA) is an artificial closed ecosystem that is considered a tool for the development of a bioregenerative life support system for manned space missions. One of the five compartments of MELiSSA loop -Higher Plant Chamber was recently integrated into the MELiSSA Pilot Plant facility at Universitat Aut`noma deo Barcelona. The main contributions expected by integration of this photosynthetic compartment are oxygen, water, vegetable food production and CO2 consumption. Production characteristics of Lactuca sativa L., as a MELiSSA candidate crop, were investigated in this work in the first crop experiments in the MELiSSA Pilot Plant facility. The plants were grown in batch culture and totaled 100 plants with a growing area 5 m long and 1 m wide in a sealed controlled environment. Several replicates of the experiments were carried out with varying duration. It was shown that after 46 days of lettuce cultivation dry edible biomass averaged 27, 2 g per plant. However accumulation of oxygen in the chamber, which required purging of the chamber, and decrease in the food value of the plants was observed. Reducing the duration of the tests allowed uninterrupted test without opening the system and also allowed estimation of the crop's carbon balance. Results of productivity, tissue composition, nutrient uptake and canopy photosynthesis of lettuce regardless of test duration are discussed in the paper.

  8. Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon

    Energy Technology Data Exchange (ETDEWEB)

    Chavez B, A.; Balcazar G, M

    1991-10-15

    To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and proved a new automatic exchanger system of passive detectors of radon. The results of the new automatic exchanger system when it leave to flow the radon freely among the container and the automatic exchanger through a plastic membrane of 15 m. are shown. (Author)

  9. Mechanical behavior of PMMA due to artificial aging by means of a xenon-test chamber; Comportamiento mecanico del polimetilmetacrilato sometido a envejecimiento artificial mediante camara xenotest

    Energy Technology Data Exchange (ETDEWEB)

    Colom, X.; Nogues, F.; Valldeperas, J.; Carrillo, F.; Gordillo, A.

    2001-07-01

    In this investigation, the mechanical behavior of poly(methylmethacrylate) due to aging in Xenon test chamber, using a xenon-arch lamp as alight radiation to simulate natural sun light has been studied. This work studies the mechanical properties (elongation at break, Young's modules, tensile strength and toughness) of PMMA samples exposed to different aging conditions (until 1560 h xenotest that correspond to 750 days exposure at natural light). The evolution of different mechanical properties characterizes the PMMA's process of degradation. (Author) 10 refs.

  10. 23rd August 2011 - Turkish Representatives of the Union of Chambers and Commodity Exchanges, E. Uluatam and S. Kologlu, visiting the LHC superconducting magnet test hall with Engineering Department Head R. Saban.

    CERN Multimedia

    Benoit Jeannet

    2011-01-01

    23rd August 2011 - Turkish Representatives of the Union of Chambers and Commodity Exchanges, E. Uluatam and S. Kologlu, visiting the LHC superconducting magnet test hall with Engineering Department Head R. Saban.

  11. A Sensitive Cloud Chamber without Radioactive Sources

    Science.gov (United States)

    Zeze, Syoji; Itoh, Akio; Oyama, Ayu; Takahashi, Haruka

    2012-01-01

    We present a sensitive diffusion cloud chamber which does not require any radioactive sources. A major difference from commonly used chambers is the use of a heat sink as its bottom plate. The result of a performance test of the chamber is given. (Contains 8 figures.)

  12. Doriot Climatic Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...

  13. Conception and test of an integrated circuit (ASIC): application to multiwire chambers and photomultipliers of the GRAAL experience; Conception et test d`un circuit integre (ASIC): application aux chambres multifils et aux photomultiplicateurs de l`experience GRAAL

    Energy Technology Data Exchange (ETDEWEB)

    Bugnet, H.

    1995-11-21

    The nuclear physics project GRAAL (GRenoble Anneau Accelerateur Laser) located at the European Synchrotron Radiation Facility (ESRF) in Grenoble produces a high energy photon beam with a maximum energy of 1.5 GeV. This gamma beam is obtained by Compton backscattering and can be polarized easily. It permits to probe, in an original way, the structure of the nucleon. The associated detector system includes multiwire proportional chambers and scintillator hodoscopes. A kit of six ASICs (Application Specific Integrated Circuit) has been developed and used for the signal processing and data conditioning up to the level of the data acquisition. This integrated electronics can be mounted right on the detectors. Obvious advantages, due to the reduction of the length of the wires and the number of connections, are an improvement of the signal quality and an increase of the reliability. The Wire Processor (WP), ASIC designed and tested during this thesis, treats the signals from the chamber wires and the photomultipliers. In one chip, there are two identical channels permitting the amplification, the amplitude discrimination, the generation of a programmable delay and the writing in a two state memory in case of coincidence with an external strobe signal. The measurement of the multiwire chamber efficiency demonstrates the functioning of the WP, the data conditioning electronics, the data acquisition and the chamber itself. (author). 62 refs., 111 figs., 13 tabs.

  14. STUDY OF DATA TRANSMISSION SYSTEMS FOR A SPACE SIMULATION CHAMBER-DESIGN AND TEST OF AN ENGINEERING MODEL,

    Science.gov (United States)

    SPACE ENVIRONMENTS, TEST FACILITIES, DATA TRANSMISSION SYSTEMS , SIMULATION, RADAR TRANSMITTERS, PULSES, AMPLITUDE MODULATION, MICROWAVES, SPACECRAFT, GIMBALS, MULTIPLEXING, ENGINEERING DRAWINGS, CIRCUITS.

  15. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  16. National Ignition Facility Target Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-10-05

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This

  17. GPS-ABC radiated chamber testing overview and results : GPS-ABC Workshop VI : RTCA Washington, DC, March 30, 2017.

    Science.gov (United States)

    2017-03-30

    This presentation, which was given during the GPS-ABC Workshop VI in Washington, DC on March 30, 2017 details the authors' radiated testing protocols and results. GPS receiver testing was carried out April 25-29, 2016 at the Army : Research Laborator...

  18. 24 CFR 3280.406 - Air chamber test method for certification and qualification of formaldehyde emission levels.

    Science.gov (United States)

    2010-04-01

    ... certification and qualification of formaldehyde emission levels. 3280.406 Section 3280.406 Housing and Urban... qualification of formaldehyde emission levels. (a) Preconditioning. Preconditioning of plywood or particleboard... with the Standard Test Method for Determining Formaldehyde Levels from Wood Products Under Defined Test...

  19. Transferring calibration coefficients from ionisation chambers used for diagnostic radiology to transmission chambers.

    Science.gov (United States)

    Yoshizumi, Maíra T; Caldas, Linda V E

    2012-07-01

    In this work, the response of a double volume transmission ionisation chamber, developed at the Instituto de Pesquisas Energéticas e Nucleares, was compared to that of a commercial transmission chamber. Both ionisation chambers were tested in different X-ray beam qualities using secondary standard ionisation chambers as reference dosimeters. These standard ionisation chambers were a parallel-plate and a cylindrical ionisation chambers, used for diagnostic radiology and mammography beam qualities, respectively. The response of both transmission chambers was compared to that of the secondary standard chambers to obtain coefficients of equivalence. These coefficients allow the transmission chambers to be used as reference equipment. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures; Sistema de medicao camara de ionizacao-eletrometro para ensaios de protecao radiologica em equipamentos de raios X para procedimentos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio

    2012-07-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10{sup 8} V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW Registered-Sign platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  1. Chemical Warfare Agent Decontamination Efficacy Testing Large-Scale Chamber mVHP (registered trademerk) Decontamination System Evaluation

    Science.gov (United States)

    2010-02-01

    aware that notwithstanding any other provision of law , no person shall be subject to any penalty for failing to comply with a collection of information...Registered users should request additional copies from the Defense Technical Information Center; unregistered users should direct such requests to the...field (surrogate) data. VHP® is a registered trademark of STERIS Corporation, 5960 Heisley Road. Mentor, OH 44060. The primary objective of this test

  2. Demonstration/Validation of the TC-60 Controlled Detonation Chamber, Porton Down, UK: Final Demonstration Test Report

    Science.gov (United States)

    2007-06-01

    System A-47 DAG Data Authentication Group DOD Department of Defense DOT Department of Transportation DSTL Defense Science and Technology Laboratory...data and prepares a test report. i. Co-chairs the Data Authentication Group (DAG). j. Provides qualified personnel to perform explosive operations... ECu > el -0 ~o < Ndh fl. 4)Ag61 M 00 E -s c E 712 -E *5 Ln 00 at~ e a rd2 __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _A 6 C) L2L C 0 00N L), - - - 00 kN

  3. Design, construction and performance tests of a prototype micromegas chamber with two readout planes in a common gas volume

    Science.gov (United States)

    Brickwedde, Bernard; Düdder, Andreas; Schott, Matthias; Yildirim, Eda

    2017-08-01

    In this paper, the design and the performance of a prototype detector based on MicroMegas technology with two detection planes in a common gas volume is discussed. The detector is suited for the forward region of LHC detectors, addressing the high-rate environment and limited available space. Each detection plane has an active area of 9 × 9cm2 with a two-dimensional strip readout and is separated by a common gas region with a height of 14 mm . A micro-mesh, working as a cathode, is placed in the middle of the common gas volume separating it into two individual cells. This setup allows for an angle reconstruction of incoming particles with a precision of ∼ 2 mrad. Since this design reduces the impact of multiple scattering effects by the reduced material budget, possible applications for low energy beam experiments can be envisioned. The performance of the prototype detector has been tested with a 4 . 4 GeV electron beam, provided by the test beam facility at DESY.

  4. Analysis of RE4 Construction Cosmic Muon Test Data and Comparison with 2015 Collision Calibration Run Data for the Newly Installed RPC Chambers in the 4th Muon Endcap Station of the CMS Detector

    CERN Document Server

    Iqbal, Muhammad Ansar

    2015-01-01

    RPC are the heart of the muon system of CMS experiment at LHC, CERN. Recently a new endcap layer, RE4, was added to increase redundancy. These added chambers were tested during the construction period with cosmic muons in the 904 lab at Prevessin, CERN. This study analyzes the HV scan from those tests and compares them with the first 2015 collision data taken at Point-5. The analysis showed that most of the chambers were producing more than 90% efficiency and were in good agreement with the Point-5 results. Those which did not give good results were reported. Other variables like working point and maximum efficiency were also studied.

  5. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Articles Absorption During Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    Science.gov (United States)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    It is important to realize that some test-articles may have significant sound absorption that may challenge the acoustic power capabilities of a test facility. Therefore, to mitigate this risk of not being able to meet the customers target spectrum, it is prudent to demonstrate early-on an increased acoustic power capability which compensates for this test-article absorption. This paper describes a concise method to reduce this risk when testing aerospace test-articles which have significant absorption. This method was successfully applied during the SpaceX Falcon 9 Payload Fairing acoustic test program at the NASA Glenn Research Center Plum Brook Stations RATF.

  6. Application of C/C composites to the combustion chamber of rocket engines. Part 1: Heating tests of C/C composites with high temperature combustion gases

    Science.gov (United States)

    Tadano, Makoto; Sato, Masahiro; Kuroda, Yukio; Kusaka, Kazuo; Ueda, Shuichi; Suemitsu, Takeshi; Hasegawa, Satoshi; Kude, Yukinori

    1995-04-01

    Carbon fiber reinforced carbon composite (C/C composite) has various superior properties, such as high specific strength, specific modulus, and fracture strength at high temperatures of more than 1800 K. Therefore, C/C composite is expected to be useful for many structural applications, such as combustion chambers of rocket engines and nose-cones of space-planes, but C/C composite lacks oxidation resistivity in high temperature environments. To meet the lifespan requirement for thermal barrier coatings, a ceramic coating has been employed in the hot-gas side wall. However, the main drawback to the use of C/C composite is the tendency for delamination to occur between the coating layer on the hot-gas side and the base materials on the cooling side during repeated thermal heating loads. To improve the thermal properties of the thermal barrier coating, five different types of 30-mm diameter C/C composite specimens constructed with functionally gradient materials (FGM's) and a modified matrix coating layer were fabricated. In this test, these specimens were exposed to the combustion gases of the rocket engine using nitrogen tetroxide (NTO) / monomethyl hydrazine (MMH) to evaluate the properties of thermal and erosive resistance on the thermal barrier coating after the heating test. It was observed that modified matrix and coating with FGM's are effective in improving the thermal properties of C/C composite.

  7. An Alternative Corrosion Resistance Test Method for Solar Cells and Interconnection Materials Limiting the Number of Long-lasting and Expensive Damp-Heat Climate Chamber Tests

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Gouwen, R.J.; Veldman, D.; Bende, E.E.; Eerenstein, W. [ECN Solar Energy, Petten (Netherlands)

    2013-06-15

    Damp-heat testing of PV modules is a time-consuming process, taking months. We present an alternative test method: electrochemical noise (EcN) measurements. Data acquisition times vary between minutes for direct exposure to several tens of hours for encapsulated samples. EcN measurements are presented for several solar cell concepts and different environments. We have found that the degradation in damp-heat testing is proportional to the electrochemical noise signal. In conclusion, the electrochemical noise measurements are a fast, versatile tool to test the corrosion resistance of solar cells, which can be tested for different environments including encapsulation.

  8. Validation of the Read Out Electronics for the CMS Muon Drift Chambers at Tests Beam in CERN/GIF; Validacion en el Test Beam del CERN/GIF de la electronica de Lectura de las Camaras de Muones del Experimento CMS

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, C.; Fouz, M. c.; Marin, J.; Oller, J. C.; Willmott, C.; Amigo, L. J.

    2002-07-01

    Part of the readout system for the CMS muon drift chambers has been tested in test beams at CERN/GIF. Read Out Board (ROB) and HPTD have been validated with signals from a real muon beam, with an structure and flux similar to LHC operating conditions and using one of the chambers produced in CIEMAT already located in the test beam area under normal gas and voltage conditions. (Author) 5 refs.

  9. "Flat-Fish" Vacuum Chamber

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The picture shows a "Flat-Fish" vacuum chamber being prepared in the ISR workshop for testing prior to installation in the Split Field Magnet (SFM) at intersection I4. The two shells of each part were hydroformed from 0.15 mm thick inconel 718 sheet (with end parts in inconel 600 for easier manual welding to the arms) and welded toghether with two strips which were attached by means of thin stainless steel sheets to the Split Field Magnet poles in order to take the vertical component of the atmospheric pressure force. This was the thinnest vacuum chamber ever made for the ISR. Inconel material was chosen for its high elastic modulus and strenght at chamber bake-out temperature. In this picture the thin sheets transferring the vertical component of the atmosferic pressure force are attached to a support frame for testing. See also 7712182, 7712179.

  10. Plasma chemistry in wire chambers

    Energy Technology Data Exchange (ETDEWEB)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed.

  11. Standard Test Method for Application of Ionization Chambers to Assess the Low Energy Gamma Component of Cobalt-60 Irradiators Used in Radiation-Hardness Testing of Silicon Electronic Devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 Low energy components in the photon energy spectrum of Co-60 irradiators lead to absorbed dose enhancement effects in the radiation-hardness testing of silicon electronic devices. These low energy components may lead to errors in determining the absorbed dose in a specific device under test. This method covers procedures for the use of a specialized ionization chamber to determine a figure of merit for the relative importance of such effects. It also gives the design and instructions for assembling this chamber. 1.2 This method is applicable to measurements in Co-60 radiation fields where the range of exposure rates is 7 × 10 −6 to 3 × 10−2 C kg −1 s−1 (approximately 100 R/h to 100 R/s). For guidance in applying this method to radiation fields where the exposure rate is >100 R/s, see Appendix X1. Note 1—See Terminology E170 for definition of exposure and its units. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information onl...

  12. D0 Central Tracking Chamber Performance Studies

    Energy Technology Data Exchange (ETDEWEB)

    Pizzuto, Domenico [State Univ. of New York (SUNY), Stony Brook, NY (United States)

    1991-01-01

    The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an $R\\Phi$ tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against $\\gamma \\to e^+ e^-$ events.

  13. D0 central tracking chamber performance studies

    Energy Technology Data Exchange (ETDEWEB)

    Pizzuto, Domenico [State Univ. of New York, Stony Brook, NY (United States)

    1991-12-01

    The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an RΦ tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against γ → e + e- events.

  14. Anechoic chamber for VHF and UHF bands

    Science.gov (United States)

    Morikawa, Takao; Sugiura, Akira; Harima, Katsushige; Masuzawa, Hiroshi

    1995-06-01

    Built in 1969, the anechoic chamber of CRL has been used to the fullest by researchers in many fields such as EMI, EMC, antenna design, standard of electric field intensity, and type approval testing. In particular, in the early days of space development in Japan, many satellite-born antennas were developed in this anechoic chamber. However, a quarter of a century has passed since its construction and deteriorated performance due to superannuation sometimes caused difficulties in experiments conducted in the chamber. In 1993, CRL constructed a Measuring Facility for Radio Research (MFRR) and the anechoic chamber for VHF-UHF bands was remodeled as one of the sub-facilities of MFRR. The remodeling work included full replacement of the electromagnetic shielding, absorbers and measurement system. Since the remodeled anechoic chamber is being used not only for EMI tests but also for other purposes, a full-anechoic chamber has been adopted. In addition the chamber has been designed for the frequency range between 30 MHz and 10 GHz. After the remodeling work, the performance of the chamber is greatly improved. The average shielding factor is better than 85 dB for all frequency ranges and the unwanted reflection characteristic is -30 dB for frequencies above 1 GHZ. This paper summarizes the remodeling work, and the specifications and performance of the remodeled anechoic chamber.

  15. HVAC&R Equipment Environmental Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — Description:Large "Truck" ChamberThe large "truck" chamber provides controlled air conditions from -7 °C (20 °F) to 65 °C (150 °F).Air-Conditioner and Heat Pump Test...

  16. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  17. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  18. DORIOT CLIMATIC CHAMBERS

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers reproduce environmental conditions occurring anywhere around the world. They provide an invaluable service by significantly reducing the...

  19. Biases in methane chamber measurements in peatlands

    Science.gov (United States)

    Juszczak, R.

    2013-03-01

    The paper presents results of CH4 emission measurements at peatland with the application of the dynamic chamber technique. The measurements were conducted in two types of chambers differing in shape, height, volume and technology used to assure their tightness. The study tested how the following factors: 1) forced chamber headspace mixing or its absence, 2) mistakes of the person conducting measurements, 3) improper application of linear technique for calculating CH4 fluxes, and 4) simulated air sampling typical for static chambers, influence the significance of errors and the underestimation rate of CH4 fluxes measured in situ. It was indicated that chamber headspace mixing allows estimating methane fluxes with a smaller error than in the case of measurements conducted without mixing, and CH4 fluxes in such conditions can be 47 to 58% higher (depending on the chamber type) than in a chamber without fans. Using dynamic chambers and a fast analyzer to measure methane fluxes allows shortening the methane measurement process to a few minutes. On the other hand, using static chambers for methane flux measurements may lead to 70% underestimation of the calculated flux.

  20. DELPHI time projection chamber

    CERN Multimedia

    1989-01-01

    The time projection chamber is inserted inside the central detector of the DELPHI experiment. Gas is ionised in the chamber as a charged particle passes through, producing an electric signal from which the path of the particle can be found. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  1. BEBC bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  2. Climatic chamber ergometer

    CSIR Research Space (South Africa)

    Atkins, AR

    1968-01-01

    Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...

  3. Relating pressure measurements to phenomena observed in high speed video recordings during tests of explosive charges in a semi-confined blast chamber

    CSIR Research Space (South Africa)

    Mostert, FJ

    2012-09-01

    Full Text Available video recordings were obtained from the open end of the chamber of the fireball and post detonative behaviour of explosive products. The framing rate of the video camera was 10 000 fps and the pressure measurements were obtained for at least 10 ms after...

  4. A Cosmic Ray Measurement Facility for ATLAS Muon Chambers

    CERN Document Server

    Biebel, O; Boutemeur, M; Brandt, A; Dubbert, J; Duckeck, G; Elmsheuser, J; Fiedler, F; Hertenberger, R; Kortner, O; Nunnemann, T; Rauscher, F; Schaile, A D; Schieferdecker, P; Staude, A; Stiller, W; Ströhmer, R; Vertesi, R

    2003-01-01

    Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map the positions of the anode wires within the chambers with the precision needed for standalone muon momentum measurement in ATLAS, and to gain experience in the operation of the chambers and on-line calibration procedures. Until the start of muon chamber installation in ATLAS, 88 chambers built at the Max Planck Institute for Physics in Munich have to be commissioned and calibrated. With a data taking period of one day individual wire positions can be measured with an accuracy of 8.3 micrometers in the chamber plane and 27 micrometers in the direction perpendicular to that plane.

  5. Microwave-range shielding effectiveness measurements using a dual vibrating intrinsic reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes; Serra, Ramiro; Schipper, H.

    2012-01-01

    Reverberation chambers create a statistical uniformly distributed field which is very useful for reliable electromagnetic interference measurements. Another advantage of these chambers is the high field strength which can be generated compared to conventional test setups. A reverberation chamber

  6. RAPID COMMUNICATION: Conducting triangular chambers for EMC measurements

    Science.gov (United States)

    Huang, Yi

    1999-03-01

    Conducting rectangular chambers have been used extensively for electromagnetic compatibility (EMC) shielding and measurement applications. In this communication, conducting triangular chambers are investigated as an alternative structure for rectangular EMC reverberation chambers, which are becoming an increasingly important and powerful tool for both radiated immunity and emission tests. A prime consideration of designing such a system is the total possible number of modes inside the chamber. A new approach is introduced to obtain this parameter for three different triangular chambers. The initial study has demonstrated that triangular chambers may offer better performance in some cases than their rectangular counterparts.

  7. Biological monitoring of isocyanates and related amines. IV. 2,4- and 2,6-toluenediamine in hydrolysed plasma and urine after test-chamber exposure of humans to 2,4- and 2,6-toluene diisocyanate.

    Science.gov (United States)

    Brorson, T; Skarping, G; Sangö, C

    1991-01-01

    Two men were exposed to toluene diisocyanate (TDI) atmospheres at three different air concentrations (ca. 25, 50 and 70 micrograms/m3). The TDI atmospheres were generated by a gas-phase permeation method, and the exposures were performed in an 8-m3 stainless-steel test chamber. The effective exposure period was 4 h. The isomeric composition of the air in the test chamber was 30% 2,4-TDI and 70% 2,6-TDI. The concentration of TDI in air of the test chamber was determined by an HPLC method using the 9-(N-methyl-amino-methyl)-anthracene reagent and by a continuous-monitoring filter-tape instrument. Following the hydrolysis of plasma and urine, the related amines, 2,4-toluenediamine (2,4-TDA) and 2,6-toluenediamine (2,6-TDA), were determined as pentafluoropropionic anhydride (PFPA) derivatives by capillary gas chromatography using selected ion monitoring (SIM) in the electron-impact mode. In plasma, 2,4- and 2,6-TDA showed a rapid-phase elimination half-time of ca. 2-5 h, and that for the slow phase was greater than 6 days. A connection was observed between concentrations of 2,4- and 2,6-TDI in air and the levels of 2,4- and 2,6-TDA in plasma. The cumulated amount of 2,4-TDA excreted in the urine over 24 h was ca. 15%-19% of the estimated inhaled dose of 2,4-TDI, and that of 2,6-TDA was ca. 17%-23% of the inhaled dose of 2,6-TDI. A connection was found between the cumulated (24-h) urinary excretion of 2,4- and 2,6-TDA and the air concentration of 2,4- and 2,6-TDI in the test chamber.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. The HERMES forward tracking chambers construction, operation, and aging effects

    CERN Document Server

    Brack, J T; Clark, S; Ely, J; Fox, B; Hofman, G J; Kinney, E R; Mercer, D J; Rakness, G; Ristinen, R A; Smythe, W R; Warner, D

    2001-01-01

    The design, construction and operation of the HERMES forward (front) tracking chambers and associated electronics are described. Resolution and limited aging tests have been performed on these drift chambers, which use an Ar/CF sub 4 /CO sub 2 (90 : 5 : 5) gas mixture. No degradation in chamber performance has been observed for a cumulative charge in excess of 9 C/cm.

  10. Central Drift Chamber for rare kaon decay spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, S.; Blackmore, E.W.; Bryman, D.A.; Cresswell, J.; Numao, T.

    1986-02-01

    Design of the Central Drift Chamber for BNL experiment 787 and measurement of a rare kaon decay are discussed. A jet chamber type cell with 6 sense wires and no interspersed field wires has been designed to achieve good spatial resolution and efficiency in a 1 T magnetic field. Results of the testing of a prototype chamber are presented.

  11. ALICE Time Projection Chamber

    CERN Multimedia

    Lippmann, C

    2013-01-01

    The Time Projection Chamber (TPC) is the main device in the ALICE 'central barrel' for the tracking and identification (PID) of charged particles. It has to cope with unprecedented densities of charges particles.

  12. Obelix Wire Chamber

    CERN Multimedia

    1986-01-01

    Two wire chambers made originally for the R807 Experiment at CERN's Intersecting Storage Rings. In 1986 they were used for the PS 201 experiment (Obelix Experiment) at LEAR, the Low Energy Antiproton Ring. The group of researchers from Turin, using the chambers at that time, changed the acquisition system using for the first time 8 bit (10 bit non linear) analog to digital conversion for incoming signals from the chambers. The acquisition system was controlled by 54 CPU and 80 digital signal processors. The power required for all the electronics was 40 kW. For the period, this system was one of the most powerful on-line apparatus in the world. The Obelix Experiment was closed in 1996. To find more about how a wire chamber works, see the description for object CERN-OBJ-DE-038.

  13. Vacuum chamber 'bicone'

    CERN Multimedia

    1977-01-01

    This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).

  14. Target Chamber Manipulator

    Science.gov (United States)

    Tantillo, Anthony; Watson, Matthew

    2015-11-01

    A system has been developed to allow remote actuation of sensors in a high vacuum target chamber used with a particle accelerator. Typically, sensors of various types are placed into the target chamber at specific radial and angular positions relative to the beam line and target. The chamber is then evacuated and the experiments are performed for those sensor positions. Then, the chamber is opened, the sensors are repositioned to new angles or radii, and the process is repeated, with a separate pump-down cycle for each set of sensor positions. The new sensor positioning system allows scientists to pre-set the radii of up to a dozen sensors, and then remotely actuate their angular positions without breaking the vacuum of the target chamber. This reduces the time required to reposition sensors from 6 hours to 1 minute. The sensors are placed into one of two tracks that are separately actuated using vacuum-grade stepping motors. The positions of the sensors are verified using absolute optical rotary encoders, and the positions are accurate to 0.5 degrees. The positions of the sensors are electronically recorded and time-stamped after every change. User control is through a GUI using LabVIEW.

  15. The KLOE drift chamber

    CERN Document Server

    Adinolfi, M; Ambrosino, F; Andryakov, A; Antonelli, A; Antonelli, M; Anulli, F; Bacci, C; Bankamp, A; Barbiellini, G; Bellini, F; Bencivenni, G; Bertolucci, Sergio; Bini, C; Bloise, C; Bocci, V; Bossi, F; Branchini, P; Bulychjov, S A; Cabibbo, G; Calcaterra, A; Caloi, R; Campana, P; Capon, G; Carboni, G; Cardini, A; Casarsa, M; Cataldi, G; Ceradini, F; Cervelli, F; Cevenini, F; Chiefari, G; Ciambrone, P; Conetti, S; Conticelli, S; Lucia, E D; Robertis, G D; Sangro, R D; Simone, P D; Zorzi, G D; Dell'Agnello, S; Denig, A; Domenico, A D; Donato, C D; Falco, S D; Doria, A; Drago, E; Elia, V; Erriquez, O; Farilla, A; Felici, G; Ferrari, A; Ferrer, M L; Finocchiaro, G; Forti, C; Franceschi, A; Franzini, P; Gao, M L; Gatti, C; Gauzzi, P; Giovannella, S; Golovatyuk, V; Gorini, E; Grancagnolo, F; Grandegger, W; Graziani, E; Guarnaccia, P; Von Hagel, U; Han, H G; Han, S W; Huang, X; Incagli, M; Ingrosso, L; Jang, Y Y; Kim, W; Kluge, W; Kulikov, V; Lacava, F; Lanfranchi, G; Lee-Franzini, J; Lomtadze, F; Luisi, C; Mao Chen Sheng; Martemyanov, M; Matsyuk, M; Mei, W; Merola, L; Messi, R; Miscetti, S; Moalem, A; Moccia, S; Moulson, M; Müller, S; Murtas, F; Napolitano, M; Nedosekin, A; Panareo, M; Pacciani, L; Pagès, P; Palutan, M; Paoluzi, L; Pasqualucci, E; Passalacqua, L; Passaseo, M; Passeri, A; Patera, V; Petrolo, E; Petrucci, Guido; Picca, D; Pirozzi, G; Pistillo, C; Pollack, M; Pontecorvo, L; Primavera, M; Ruggieri, F; Santangelo, P; Santovetti, E; Saracino, G; Schamberger, R D; Schwick, C; Sciascia, B; Sciubba, A; Scuri, F; Sfiligoi, I; Shan, J; Silano, P; Spadaro, T; Spagnolo, S; Spiriti, E; Stanescu, C; Tong, G L; Tortora, L; Valente, E; Valente, P; Valeriani, B; Venanzoni, G; Veneziano, Stefano; Wu, Y; Xie, Y G; Zhao, P P; Zhou, Y

    2001-01-01

    The tracking detector of the KLOE experiment is 4 m diameter, 3.3 m length drift chamber, designed to contain a large fraction of the decays of low-energy K sub L produced at the Frascati DAPHINE phi-factory. The chamber is made by a thin carbon fiber structure and operated with a helium-based gas mixture in order to minimise conversion of low-energy photons and multiple scattering inside the sensitive volume. The tracking information is provided by 58 layers of stereo wires defing 12,582 cells, 2x2 cm sup 2 in size in the 12 innermost layers and 3x3 cm sup 2 in the outer ones. Details of the chamber design, calibration procedure and tracking performances are presented.

  16. DELPHI Barrel Muon Chamber Module

    CERN Multimedia

    1989-01-01

    The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.

  17. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  19. A new Open Top Chamber designed to test in situ effects of climatic and atmospheric changes on nitrogen fixation in boreal forest floor mosses

    Science.gov (United States)

    Bringuier, Charline; Bradley, Robert; Bellenger, Jean-Philippe; Morin, Hubert; Lindo, Zoë

    2014-05-01

    Biological nitrogen fixation (BNF) by cyanobacteria dwelling in forest floor moss layers is an important determinant of boreal black spruce forest productivity. Recent studies have suggested that these BNF rates may increase with increasing atmospheric CO2 and increasing temperature, as predicted by current weather models. This potential increase in BNF may be offset, however, by increasing atmospheric deposition of nitrogen, or by increasing demands for phosphorus (i.e. driving nodular ATP content) and for micronutrients such as Mo, Va and Fe (i.e. co-factors of nitrogenase enzyme). In order to study the relative and interactive effects of these factors controlling in situ BNF rates in boreal forest floor moss layers, a new Open Top Chamber (OTC) was developed in summer of 2013. The chambers measure 1.60 cm dia. × 60 cm height, and are equipped with an automated CO2 delivery system designed to maintain atmospheric daytime CO2 concentrations at 800 ppm, as well as buried heating coils that increase soil temperature by 4 ° C for 3 weeks in springtime. These 2 experimental factors are crossed in a full factorial (2 × 2) design that is replicated in 4 complete blocks. Each of the 16 OTCs is divided into 4 compartments, each of which are assigned 1 of 4 sub-plot factors. These include chronic additions of either atmospheric nitrogen, phosphorus, micronutrients or a non-amended control. Staring in summer 2014, a series of measurements will be made to assess the effects of treatments on BNF rates, cyanobacterial colonization and soil nitrogen cycling. Our poster will describe in detail the design and operation of the OTCs, as well as their construction and maintenance costs.

  20. Proposal for the award of a contract, without competitive tendering, for the manufacture and testing of 360 000 field strip cathodes for the drift tube chambers of the CMS muon detector

    CERN Document Server

    1999-01-01

    The Finance Committee is invited to authorize CERN to negotiate on behalf of the Participating Institutes of the CMS Collaboration a contract, without competitive tendering, with the JOINT INSTITUTE FOR NUCLEAR RESEARCH (JINR), Dubna, Russia, for the manufacture and testing of 360 000 field strip cathodes for the drift tube chambers of the CMS Muon Detector, for a total amount of 140 000 US dollars, not subject to revision. At the present rate of exchange, this amount is equivalent to approximately 210 000 Swiss francs.

  1. LEP Vacuum Chamber

    CERN Multimedia

    1983-01-01

    This is a cut-out of a LEP vacuum chamber for dipole magnets showing the beam channel and the pumping channel with the getter (NEG) strip and its insulating supports. A water pipe connected to the cooling channel can also be seen at the back.The lead radiation shield lining is also shown. See also 8305563X.

  2. Scanning bubble chamber pictures

    CERN Multimedia

    1974-01-01

    These were taken at the 2 m hydrogen bubble chamber. The photo shows an early Shiva system where the pre-measurements needed to qualify the event were done manually (cf photo 7408136X). The scanning tables were located in bld. 12. Gilberte Saulmier sits on foreground, Inge Arents at centre.

  3. Heavy liquid bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The CERN Heavy liquid bubble chamber being installed in the north experimental hall at the PS. On the left, the 1180 litre body; in the centre the magnet, which can produce a field of 26 800 gauss; on the right the expansion mechanism.

  4. Rocket Combustion Chamber Coating

    Science.gov (United States)

    Holmes, Richard R. (Inventor); McKechnie, Timothy N. (Inventor)

    2001-01-01

    A coating with the ability to protect (1) the inside wall (i.e., lining) of a rocket engine combustion chamber and (2) parts of other apparatuses that utilize or are exposed to combustive or high temperature environments. The novelty of this invention lies in the manner a protective coating is embedded into the lining.

  5. Chamber Profile Measurement System.

    Science.gov (United States)

    1980-10-01

    travel with the proper electronics. Other features of tihe gage assembly are: 1. Micrometer controlled down chamber positioning of the master template to...pressure sensitive "stiff stick" for infinitely varying the rate of travel from zero to maximum. A manual vernier control is incorporated to permit fine

  6. LEP vacuum chamber, prototype

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Final prototype for the LEP vacuum chamber, see 8305170 for more details. Here we see the strips of the NEG pump, providing "distributed pumping". The strips are made from a Zr-Ti-Fe alloy. By passing an electrical current, they were heated to 700 deg C.

  7. Using reverberation chambers for em measurements

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2010-01-01

    Reverberation chambers (RC) are being used for several decades. The main advantage is the high field strength which can be generated, with only modest power. In the last few years the use of RCs became much popular, for testing multi-path propagation for communication links, or testing the coupling

  8. GRCop-84 Development for Combustion Chamber Liners

    Science.gov (United States)

    Ellis, David; Nathal, Michael; Yun, Hee Man; Lerch, Bradley; Greenbauer-Seng, Leslie; Thomas-Ogbuji, Linus; Holmes, Richard

    2000-01-01

    The development, test, and thermophysical & mechanical properties of a GRCop-84 alloy for combustion chamber liners is discussed. Topics discussed include: History of GRCop-84 development, GRCop-84 thermal expansion, thermal conductivity of GRCop-84, yield strength of GRCop-84, GRCop-84 creep lives, GrCop-84 low cycle fatigue (LCF) lives, and hot fire testing of GRCop-84 spool pieces.

  9. Comparison of static chambers to measure CH4 emissions from soils

    NARCIS (Netherlands)

    Pihlatie, M.K.; Christiansen, J.R.; Aaltonen, H.; Korhonen, J.F.J.; Nordbo, A.; Rasilo, T.; Benanti, G.; Giebels, M.; Helmy, M.; Sheehy, J.; Jones, S.; Juszczak, R.; Klefoth, R.R.; Lobo-do-Vale, R.; Rosa, A.P.; Schreiber, P.; Serca, D.; Vicca, S.; Wolf, B.; Pumpanen, J.

    2013-01-01

    The static chamber method (non-flow-through-non-steady-state chambers) is the most common method to measure fluxes of methane (CH4) from soils. Laboratory comparisons to quantify errors resulting from chamber design, operation and flux calculation methods are rare. We tested fifteen chambers against

  10. Multiwire proportional chamber development

    Science.gov (United States)

    Doolittle, R. F.; Pollvogt, U.; Eskovitz, A. J.

    1973-01-01

    The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.

  11. Permeability of MDT chambers to water vapor

    CERN Document Server

    Palestini, S

    2003-01-01

    Tests of MDT chambers performed at the GIF facility and in the H8 test-beam area have shown relative high levels of water vapor contamination in the gas-mixture at the detector output. This effects significantly the drift properties of the MDTs. This note shows that amount of water observed is compatible with approximate estimates based on the permeability of Noryl, used in the tube end-plugs, and of EPDM, used in the O-rings of the on-chamber gas distribution.

  12. Characterization of a homemade ionization chamber for radiotherapy beams

    Energy Technology Data Exchange (ETDEWEB)

    Neves, Lucio P., E-mail: lpneves@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil); Perini, Ana P., E-mail: aperini@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil); Santos, Gelson P. dos, E-mail: gpsantos@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil); Xavier, Marcos, E-mail: mxavier@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.br [Universidade Federal de Pernambuco, Departamento de Energia Nuclear, Av. Prof. Luiz Freire 1000, 50740-540 Recife (Brazil); Caldas, Linda V.E., E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil)

    2012-07-15

    A homemade cylindrical ionization chamber was studied for routine use in therapy beams of {sup 60}Co and X-rays. Several characterization tests were performed: leakage current, saturation, ion collection efficiency, polarity effect, stability, stabilization time, chamber orientation and energy dependence. All results obtained were within international recommendations. Therefore the homemade ionization chamber presents usefulness for routine dosimetric procedures in radiotherapy beams. - Highlights: Black-Right-Pointing-Pointer A homemade ionization chamber was studied for routine use in radiotherapy. Black-Right-Pointing-Pointer Several characterization tests were performed and the results were satisfactory. Black-Right-Pointing-Pointer This chamber was compared to commercial ones and the results were similar. Black-Right-Pointing-Pointer This chamber is suitable for calibration procedures in {sup 60}Co beams.

  13. Vacuum Chambers for LEP sections

    CERN Multimedia

    1983-01-01

    The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.

  14. Central drift chamber for rare kaon decay spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, S.; Blackmore, E.W.; Bryman, D.A.; Cresswell, J.; Numao, T.

    1985-10-01

    Design of the central drift chamber for BNL experiment 787 and measurement of the decay K/sup +/ ..-->.. ..pi../sup +/ nu anti nu are discussed. A jet chamber type cell with 6 sense wires and no interspersed field wires has been designed to achieve good spatial resolution and efficiency in a 1 T magnetic field. Results of the testing of a prototype chamber are presented.

  15. Wire chambers revisited.

    Science.gov (United States)

    Ott, R J

    1993-04-01

    Detectors used for radioisotope imaging have, historically, been based on scintillating crystal/photomultiplier combinations in various forms. From the rectilinear scanner through to modern gamma cameras and positron cameras, the basic technology has remained much the same. Efforts to overcome the limitations of this form of technology have foundered on the inability to reproduce the required sensitivity, spatial resolution and sensitive area at acceptable cost. Multiwire proportional chambers (MWPCs) have long been used as position-sensitive charged particle detectors in nuclear and high-energy physics. MWPCs are large-area gas-filled ionisation chambers in which large arrays of fine wires are used to measure the position of ionisation produced in the gas by the passage of charged particles. The important properties of MWPCs are high-spatial-resolution, large-area, high-count-rate performance at low cost. For research applications, detectors several metres square have been built and small-area detectors have a charged particle resolution of 0.4 mm at a count rate of several million per second. Modification is required to MWPCs for nuclear medicine imaging. As gamma rays or X-rays cannot be detected directly, they must be converted into photo- or Compton scatter electrons. Photon-electron conversion requires the use of high atomic number materials in the body of the chamber. Pressurised xenon is the most useful form of "gas only" photon-electron convertor and has been used successfully in a gamma camera for the detection of gamma rays at energies below 100 keV. This camera has been developed specifically for high-count-rate first-pass cardiac imaging. This high-pressure xenon gas MWPC is the key to a highly competitive system which can outperform scintillator-based systems. The count rate performance is close to a million counts per second and the intrinsic spatial resolution is better than the best scintillator-based camera. The MWPC camera produces quantitative

  16. Review of wire chamber aging

    Energy Technology Data Exchange (ETDEWEB)

    Va' Vra, J.

    1986-02-01

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs.

  17. Posterior chamber pseudophakia.

    Science.gov (United States)

    Simcoe, C W

    1982-01-01

    Anatomically, the most physiological type of implant is that of the posterior chamber of the eye. After a brief historical review of these implants, two models differing by their loops are compared, these being either in the form of a J with narrow extremities or in the form of a C. The latter model possesses definite advantages. Firstly, the point of pressure on the lens capsule is less concentrated, reducing the pressure exerted by the loops and thus avoiding rupture of the zonular ciliaris, Secondly, contact in the form of an are prevents movement of the implant around its axis, a factor favorizing capsule slipping. Thirdly, the improved pressure distribution of the loops resulting from their greater flexibility also prevents the "windscreen wiper syndrome", providing improved stability of the implant. The technique employed avoids all contact taking place with the endothelium. The upper loop is placed in position after closure of the incision. Results in 1532 cases were very positive, and studies are currently being conducted with an implant with four loops in which the optic is within the posterior chamber, and which could be positioned after intracapsular extraction. A system of irrigation-aspiration is described which employs a fine curved canula that is easier to manage and permits improved cleaning of the capsule. Emphasis is placed on the need for narrow, deep, corneal sutures to reduce postoperative astigmatism.

  18. Council Chamber exhibition

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    To complete the revamp of CERN’s Council Chamber, a new exhibition is being installed just in time for the June Council meetings.   Panels will showcase highlights of CERN’s history, using some of the content prepared for the exhibitions marking 50 years of the PS, which were displayed in the main building last November. The previous photo exhibition in the Council Chamber stopped at the 1970s. To avoid the new panels becoming quickly out of date, photos are grouped together around specific infrastructures, rather than following a classic time-line. “We have put the focus on the accelerators – the world-class facilities that CERN has been offering researchers over the years, from the well-known large colliders to the lesser-known smaller facilities,” says Emma Sanders, who worked on the content. The new exhibition will be featured in a future issue of the Bulletin with photos and an interview with Fabienne Marcastel, designer of the exhibit...

  19. Readout system for proportional wire chambers

    CERN Document Server

    Berst, J D; Metzger, G; Meyer, J M; Schultz, G

    1974-01-01

    The authors describe a MWPC read-out system intended for the hyperon experiments at CERN. Its structure is like the familiar CAMAC branch highway, but driven by a spark chamber readout module placed in CAMAC. The different parts of the equipment, which may read up to 4096 wires, and the test system are described. (5 refs).

  20. Thermal Vacuum Chamber Repressurization with Instrument Purging

    Science.gov (United States)

    Woronowicz, Michael

    2017-01-01

    At the end of James Webb Space Telescope (JWST) OTIS (Optical Telescope Element-OTE-Integrated Science Instrument Module-ISIM) cryogenic vacuum testing in NASA Johnson Space Centers (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are mooting the idea that chamber particulate material stirred up by the repressurization process may be kept from falling into the ISIM interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This memo describes development of a series of models designed to describe this process. These are strung together in tandem to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

  1. Achieving ultrahigh vacuum in an unbaked chamber with glow ...

    Indian Academy of Sciences (India)

    Glow discharge conditioning (GDC) has long been accepted as one of the basic wall conditioning techniques for achieving ultrahigh vacuum in an unbaked chamber. As a part of this fundamental experimental study, a test chamber has been fabricated from stainless steel 304 L with its inner surface electropolished on ...

  2. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  3. Inlet noise on 0.5-meter-diameter NASA QF-1 fan as measured in an unmodified compressor aerodynamic test facility and in an anechoic chamber

    Science.gov (United States)

    Gelder, T. F.; Soltis, R. F.

    1975-01-01

    Narrowband analysis revealed grossly similar sound pressure level spectra in each facility. Blade passing frequency (BPF) noise and multiple pure tone (MPT) noise were superimposed on a broadband (BB) base noise. From one-third octave bandwidth sound power analyses the BPF noise (harmonics combined), and the MPT noise (harmonics combined, excepting BPF's) agreed between facilities within 1.5 db or less over the range of speeds and flows tested. Detailed noise and aerodynamic performance is also presented.

  4. Study of ignition, combustion, and production of harmful substances upon burning solid organic fuel at a test bench with a vortex chamber

    Science.gov (United States)

    Burdukov, A. P.; Chernetskiy, M. Yu.; Dekterev, A. A.; Anufriev, I. S.; Strizhak, P. A.; Greben'kov, P. Yu.

    2016-01-01

    Results of investigation of furnace processes upon burning of pulverized fuel at a test bench with a power of 5 MW are presented. The test bench consists of two stages with tangential air and pulverized coal feed, and it is equipped by a vibrocentrifugal mill and a disintegrator. Such milling devices have an intensive mechanical impact on solid organic fuel, which, in a number of cases, increases the reactivity of ground material. The processes of ignition and stable combustion of a mixture of gas coal and sludge (wastes of concentration plant), as well as Ekibastus coal, ground in the disintegrator, were studied at the test bench. The results of experimental burning demonstrated that preliminary fuel grinding in the disintegrator provides autothermal combustion mode even for hardly inflammable organic fuels. Experimental combustion of biomass, wheat straw with different lignin content (18, 30, 60%) after grinding in the disintegrator, was performed at the test bench in order to determine the possibility of supporting stable autothermal burning. Stable biofuel combustion mode without lighting by highly reactive fuel was achieved in the experiments. The influence of the additive GTS-Powder (L.O.M. Leaders Co., Ltd., Republic of Korea) in the solid and liquid state on reducing sulfur oxide production upon burning Mugun coal was studied. The results of experimental combustion testify that, for an additive concentration from 1 to 15% of the total mass of the burned mixture, the maximum SO2 concentration reduction in ejected gases was not more than 18% with respect to the amount for the case of burning pure coal.

  5. The ALICE time projection chamber

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    This time projection chamber is part of the ALICE detector on the new LHC accelerator at CERN. Particles produced in collisions at the core of the detector will follow paths outward through the various sub-detector layers. If these particles carry a charge, they will ionise the gas contained within this chamber producing an electric signal as the ions drift in the chamber's electric field.

  6. Portable electron beam weld chamber

    Science.gov (United States)

    Lewis, J. R.; Dimino, J. M.

    1972-01-01

    Development and characteristics of portable vacuum chamber for skate type electron beam welding are discussed. Construction and operational details of equipment are presented. Illustrations of equipment are provided.

  7. Improvement of a test-chamber for behavioral studies on adult females of Aedes aegypti (Linnaeus (Diptera, Culicidae Aperfeiçoamento de uma câmara-teste para estudos comportamentais com fêmeas adultas de Aedes aegypti (Linnaeus (Diptera, Culicidae

    Directory of Open Access Journals (Sweden)

    Isaías Cabrini

    2007-01-01

    Full Text Available A test-chamber (K&L-Chamber made of cardboard and acrylic plastic, and consisting in four sections (A, B, C and D was developed by Klowden & Lea (1978 for Aedes aegypti host-seeking behavior studies. Later, Foster & Lutes (1985 also used an identical chamber to successfully evaluate the efficacy of electronic repellers. It was described here a modified K&L-Chamber for behavioral studies of Ae. aegypti adults. The chamber was made in polystyrene, consisting of three sections (A, B and C and using a human hand and a fluorescent lamp as stimulus to attract the mosquitoes. The suitability of the present test-chamber was validated assaying 80 replicates and releasing 10 Ae. aegypti females in each replicate. The females were released in the section A and allowed to fly to the section C. A mean of 96.0% (s.e. 0.213 Ae. aegypti females successfully reached section C. The present test-chamber is cheaper and easier to handle and as efficient as K&L-Chamber, when compared to Foster & Lutes (1978 that noticed 93.8% of Ae. aegypti reaching the trap section.Uma câmara-teste (Câmara K&L feita de papelão e plástico acrílico, e consistindo em quatro seções (A, B, C e D foi desenvolvida por Klowden & Lea (1978 para estudos sobre o comportamento de busca pelo hospedeiro por Aedes aegypti. Foster & Lutes (1985 também usaram uma câmara idêntica para, com sucesso, avaliar a eficácia de repelentes eletrônicos. Aqui foi descrita uma Câmara K&L modificada (Câmara K&L-Unicamp para estudos comportamentais com adultos de Ae. aegypti. A câmara foi feita com isopor, consistindo em três seções (A, B e C e usando uma mão humana e uma lâmpada fluorescente para atrair os mosquitos. A adequação da presente câmara-teste foi validada por meio de 80 repetições, cada uma com liberação de 10 fêmeas de Ae. aegypti. As fêmeas foram liberadas na seção A e permitidas voar para a seção C. Uma média de 96,0% (e.p. 0,213 de fêmeas de Ae. aegypti chegaram a

  8. Proposal for a Full-Scale Prototype Single-Phase Liquid Argon Time Projection Chamber and Detector Beam Test at CERN

    CERN Document Server

    Kutter, T

    2015-01-01

    The Deep Underground Neutrino Experiment (DUNE) will use a large liquid argon (LAr) detector to measure the CP violating phase, determine the neutrino mass hier- archy and perform precision tests of the three-flavor paradigm in long-baseline neutrino oscillations. The detector will consist of four modules each with a fiducial mass of 10 kt of LAr and due to its unprecedented size will allow sensitive searches for proton decay and the detection and measurement of electron neutrinos from core collapse supernovae [1]. The first 10 kt module will use single-phase LAr detection technique and be itself modular in design. The successful manufacturing, installation and operation of several full-scale detector components in a suitable configuration represents a critical engineering milestone prior to the construction and operation of the first full 10 kt DUNE detector module at the SURF underground site. A charged particle beam test of a prototype detector will provide critical calibration measurements as well as inva...

  9. Dual reverberation chambers for high-dynamic range shielding effectiveness measurements

    NARCIS (Netherlands)

    Schipper, J.; Melenhorst, M.; Leferink, Frank Bernardus Johannes

    2008-01-01

    We describe a test setup using two reverberation chambers with a common wall. In the common wall a device under test (DUT) can be mounted. One of the rooms is a conventional chamber with a stirrer. The other room is a Vibrating Intrinsic Reverberation Chamber (VIRC), where the walls are used to stir

  10. Integration of a Higher Plant Chamber into the European Space Agency's MELiSSA Pilot Plant: The Canadian Role in Advanced Life Support Test-Bed Development

    Science.gov (United States)

    Waters, Geoffrey; Lawson, Jamie; Gidzinski, Danuta; Stasiak, Michael; Dixon, Mike; Peiro, Enrique; Godia, Francesc; Paille, Christel; Fossen, Arnaud; Lamaze, Brigitte; Lasseur, Christophe

    The European Space Agency's Micro-Ecological Life Support System Alternative (MELiSSA) project has been conceived as a tool for developing the technology of future biological life support systems required for long-term human space exploration missions to the Moon or Mars. The main life support functions of MELiSSA are the recycling of waste (inedible plant biomass, human excrement), carbon dioxide and minerals and the production of food, fresh water and air revitalization. Based on the principle of an aquatic ecosystem, MELiSSA is comprised of four microbial compartments and a higher plant compartment integrated in a closed loop. Each compartment is studied, designed and demonstrated at laboratory scale before being scaled-up for subsequent integration into the MELISSA Pilot Plant (MPP) at the Universitat Aut`noma de Barcelona. Work related to higher plant cultivation systems, o which have been historically focussed at the University of Guelph's Controlled Environment Systems Research Facility (CESRF), has included design of the HPC for the MPP, the metabolic characterization of MELiSSA candidate crops and the validation of theoretical gas exchange and nutrient dynamic models, The presented paper will review some of the recent data and HPC design work of CESRF conducted as part of Canada's involvement in the MELiSSA program and its partnership in the development of the MPP terrestrial demonstration test-bed.

  11. The Big European Bubble Chamber

    CERN Multimedia

    1977-01-01

    The 3.70 metre Big European Bubble Chamber (BEBC), dismantled on 9 August 1984. During operation it was one of the biggest detectors in the world, producing direct visual recordings of particle tracks. 6.3 million photos of interactions were taken with the chamber in the course of its existence.

  12. Characterization of a Reverberation Chamber

    Science.gov (United States)

    2015-10-01

    applied to the same device inside another facility, such as a gigahertz transverse electromagnetic (GTEM) or fully- anechoic chamber for further...and found to be consistent; reflections measured from inside the chamber yielded heavy spiking. The antenna used to transmit power into the room was

  13. The CLEO III drift chamber

    CERN Document Server

    Peterson, D; Briere, R A; Chen, G; Cronin-Hennessy, D; Csorna, S; Dickson, M; Dombrowski, S V; Ecklund, K M; Lyon, A; Marka, S; Meyer, T O; Patterson, J R; Sadoff, A; Thies, P; Thorndike, E H; Urner, D

    2002-01-01

    The CLEO group at the Cornell Electron Storage Ring has constructed and commissioned a new central drift chamber. With 9796 cells arranged in 47 layers ranging in radius from 13.2 to 79 cm, the new drift chamber has a smaller outer radius and fewer wires than the drift chamber it replaces, but allows the CLEO tracking system to have improved momentum resolution. Reduced scattering material in the chamber gas and in the inner skin separating the drift chamber from the silicon vertex detector provides a reduction of the multiple scattering component of the momentum resolution and an extension of the usable measurement length into the silicon. Momentum resolution is further improved through quality control in wire positioning and symmetry of the electric fields in the drift cells which have provided a reduction in the spatial resolution to 88 mu m (averaged over the full drift range).

  14. Achievable field strength in reverberation chambers

    Directory of Open Access Journals (Sweden)

    N. Eulig

    2003-01-01

    Full Text Available Feldvariable Kammern (FVK, engl.: modestirred- chamber werden unter anderem für EMV-Störfestigkeitsprüfungen verwendet. Ein häufig genanntes Argument, das die Einführung dieser Kammern als normgerechte Prüfumgebung vorantreiben soll, ist eine hohe Feldstärke, die im Vergleich zu anderen Testumgebungen mit relativ moderaten HF-Leistungen erreicht werden kann. Besonders für sicherheitskritische Geräte, wie Komponenten aus der Avionik- oder KFZ-Industrie, sind heutzutage Testfeldstärken von mehreren 100 V/m notwendig. Derart hohe Feldstärken können in Umgebungen, die ein ebenes Wellenfeld erzeugen oder nachbilden, nur mit großen HFLeistungen generiert werden. Durch die Resonanzeigenschaften einer FVK können demgegenüber mit sehr viel weniger Leistung und damit Verstärkeraufwand vergleichbare Werte der Feldstärke erzeugt werden. Allerdings sinkt mit zunehmendem Volumen die erreichbare Feldstärke bei gleicher Speiseleistung. Idealerweise sollen Feldvariable Kammern bei möglichst niedrigen Frequenzen für EMVTests nutzbar sein, was jedoch ein großes Kammervolumen erfordert. Das Problem, bei niedrigen Frequenzen hohe Feldstärken erzeugen zu können, relativiert deshalb den Vorteil von FVKn gegenüber bekannten Testumgebungen bei niedrigen Testfrequenzen. Der Posterbeitrag erläutert, welche Feldstärken in verschieden großen Feldvariablen Kammern beim Einspeisen einer bestimmten hochfrequenten Leistung erreicht werden können. Anhand dieser Ergebnisse wird aufgezeigt, oberhalb welcher Grenzfrequenz eine Anwendung von FVKn nur sinnvoll erscheint. Mode-stirred chambers (MSCs can be used for radiated immunity tests in EMC testing. Advantageous compared to conventional test methods is the high field strength which can here be generated with less RF-Power. This point is often the main argument for pushing the standardization of MSCs as an other EMC testing environment. Especially for safety-critical electronic equipment like avionic or

  15. Methods of Testing Thermal Insulation and Associated Test Apparatus

    Science.gov (United States)

    2004-01-01

    The system and method for testing thermal insulation uses a cryostatic insulation tester having a vacuum chamber and a cold mass including a test chamber and upper and lower guard chambers adjacent thereto. The thermal insulation is positioned within the vacuum chamber and adjacent the cold mass. Cryogenic liquid is supplied to the test chamber, upper guard and lower guard to create a first gas layer in an upper portion of the lower guard chamber and a second gas layer in an upper portion of the test chamber. Temperature are sensed within the vacuum chamber to test the thermal insulation.

  16. Effect of Chamber Wall Proximity on Radiometer Force Production (Preprint)

    National Research Council Canada - National Science Library

    Selden, N. P; Gimelshein, N. E; Gimelshein, S. F; Ketsdever, A. D

    2008-01-01

    ... on a given radiometer configuration in both the free molecule and transitional regimes. The contribution of the chamber walls to both the flowfield structure and radiometric force production were examined for helium, argon, and nitrogen test gases...

  17. Wideband MIMO Channel Capacity Analysis in Multiprobe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Fan, Wei; Kyosti, Pekka; Nielsen, Jesper Ødum

    2016-01-01

    This paper discusses over the air (OTA) testing for multiple input multiple output (MIMO) capable terminals with emphasis on wideband MIMO channel capacity analysis in a multi-probe anechoic chamber setup. In the literature, the spatial correlation simulation accuracy at the receiver (Rx) side has...... in a practical multi-probe anechoic chamber setup. The capacity simulation accuracy is shown to be a valid measure to determine the test area size....

  18. VOC emissions chambers

    Data.gov (United States)

    Federal Laboratory Consortium — In order to support the development of test methods and reference materials for volatile organic compounds (VOC) emissions from building materials and furnishings,...

  19. Characterization of a CT ionization chamber for radiation field mapping

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana P., E-mail: aperini@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000, Sao Paulo, SP (Brazil); Neves, Lucio P., E-mail: lpneves@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000, Sao Paulo, SP (Brazil); Vivolo, Vitor, E-mail: vivolo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000, Sao Paulo, SP (Brazil); Xavier, Marcos, E-mail: mxavier@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000, Sao Paulo, SP (Brazil); Khoury, Helen J., E-mail: hjkhoury@gmail.com [Universidade Federal de Pernambuco, Departamento de Energia Nuclear, Av. Prof. Luiz Freire 1000, 50740-540, Recife, PE (Brazil); Caldas, Linda V.E., E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000, Sao Paulo, SP (Brazil)

    2012-07-15

    A pencil-type ionization chamber, developed at Instituto de Pesquisas Energeticas e Nucleares (IPEN), was characterized with the objective to verify the possibility of its application in radiation field mapping procedures. The characterization tests were evaluated, and the results were satisfactory. The results obtained for the X radiation field mapping with the homemade chamber were compared with those of a PTW Farmer-type chamber (TN 30011-1). The maximum difference observed in this comparison was only 1.25%, showing good agreement. - Highlights: Black-Right-Pointing-Pointer A new ionization chamber was made and tested for radiation field mapping. Black-Right-Pointing-Pointer This ionization chamber was made using only accessible low cost materials. Black-Right-Pointing-Pointer The operational tests were made and the results were within the recommended limits. Black-Right-Pointing-Pointer The field map was compared with a commercial chamber presenting a 1.25% difference. Black-Right-Pointing-Pointer Our chamber presents potential for assurance reliability in calibration procedures.

  20. Influence of chamber misalignment on cased telescoped (CT ammunition accuracy

    Directory of Open Access Journals (Sweden)

    D. Corriveau

    2016-04-01

    Full Text Available As part of a research program, it was desired to better understand the impact of the rotating chamber alignment with the barrel throat on the precision and accuracy of a novel cased telescoped (CT ammunition firing rifle. In order to perform the study, a baseline CT ammunition chamber which was concentric with a Mann barrel bore was manufactured. Additionally, six chambers were manufactured with an offset relative to the barrel bore. These chambers were used to simulate a misaligned chamber relative to the bore axis. Precision and accuracy tests were then performed at 200 m in an indoor range under controlled conditions. For this project, 5.56 mm CT ammunition was used. As the chamber axis offset relative to the gun bore was increased, the mean point of impact was displaced away from the target center. The shift in the impact location is explained by the presence of in-bore yaw which results in lateral throw-off and aerodynamic jump components. The linear theory of ballistics is used to establish a relationship between the chamber misalignment and the resulting projectile mean point of impact for a rifle developed to fire CT ammunition. This relationship allows for the prediction of the mean point of impact given a chamber misalignment.

  1. Around the laboratories: Rutherford: Successful tests on bubble chamber target technique; Stanford (SLAC): New storage rings proposal; Berkeley: The HAPPE project to examine cosmic rays with superconducting magnets; The 60th birthday of Professor N.N. Bogolyubov; Argonne: Performance of the automatic film measuring system POLLY II

    CERN Multimedia

    1969-01-01

    Around the laboratories: Rutherford: Successful tests on bubble chamber target technique; Stanford (SLAC): New storage rings proposal; Berkeley: The HAPPE project to examine cosmic rays with superconducting magnets; The 60th birthday of Professor N.N. Bogolyubov; Argonne: Performance of the automatic film measuring system POLLY II

  2. Drift chambers for a precision measurement of the Michel parameters in muon decay

    CERN Document Server

    Davydov, Y; Comyn, M; Depommier, P; Doornbos, J; Faszer, W; Gagliardi, C A; Gill, D R; Green, P; Gumplinger, P; Hardy, J C; Hasinoff, M D; Helmer, R; Henderson, R; Khruchinsky, A; Kitching, P; Koetke, D D; Korkmaz, E J; Lachin, Yu Yu; Maas, D; MacDonald, J A; MacDonald, R; Manweiler, R; Marshall, G; Mathie, E L; Miassoedov, L; Musser, J R; Nord, P M; Olin, A; Openshaw, R; Ottewell, D; Porcelli, T; Poutissou, J M; Poutissou, R; Price, G; Quraan, M A; Rodning, N L; Schaapman, J; Selivanov, V; Sheffer, G; Shin, B; Sobratee, F; Soukup, J; Stanislaus, T D S; Stinson, G M; Tacik, R; Torokhov, V D; Tribble, R E; Vasilev, M A; Walter, H C; Wright, D

    2001-01-01

    Planar drift chambers will be used in a solenoidal magnetic field to measure the Michel parameters in muon decay. The chamber manufacture procedure uses flat glass tables and precise ceramic glass spacers to provide precise anode-cathode spacing. Results of bench and beam tests of the prototype chambers are discussed.

  3. Monitored Drift Tube (MDT) chambers for precise measurement of muon trajectories in the ATLAS muon spectrometer.

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    The basic detection component of the chamber is the cylindrical, aluminium, gas-filled MDT with its central tungsten rhenium wire. Each chamber is an assembly of two parallel multilayers of MDTs separated by a spacer frame. The chambers are pictured here in building 887 on the Prévessin site where they are being tested.

  4. Purging device for suppression chamber

    Energy Technology Data Exchange (ETDEWEB)

    Yoshino, Koichi.

    1987-11-14

    Purpose: To completely drive out air or the like in the suppression chamber in a short period of time thereby protect bent pipes from embrittled rupture. Constitution: Nitrogen gases, etc. entering through the inlet penetration to the inside of a reactor container are guided downwardly through communication pipeways, and the released downwardly in a stable manner while the blowing speed being retained by blowing mechanisms. Released nitrogen gases, etc. diffuse along the water surface of the suppression chamber and fill the inside of the chamber from below. Air, etc. in the suppression chamber prior to the supply of nitrogen gas, etc. is discharged through the exit penetration from the purging discharge pipe smoothly to the outside. In this way, air is replaced with nitrogen gas, etc., the released nitrogen is not directly blown to bent pipe, the operation is simplified, and the charge/discharge operation can be made in a short time efficiently. (Kamimura, M.).

  5. Vaporization chambers and associated methods

    Science.gov (United States)

    Turner, Terry D.; Wilding, Bruce M.; McKellar, Michael G.; Shunn, Lee P.

    2017-02-21

    A vaporization chamber may include at least one conduit and a shell. The at least one conduit may have an inlet at a first end, an outlet at a second end and a flow path therebetween. The shell may surround a portion of each conduit and define a chamber surrounding the portion of each conduit. Additionally, a plurality of discrete apertures may be positioned at longitudinal intervals in a wall of each conduit, each discrete aperture of the plurality of discrete apertures sized and configured to direct a jet of fluid into each conduit from the chamber. A liquid may be vaporized by directing a first fluid comprising a liquid into the inlet at the first end of each conduit, directing jets of a second fluid into each conduit from the chamber through discrete apertures in a wall of each conduit and transferring heat from the second fluid to the first fluid.

  6. The multigap resistive plate chamber

    Energy Technology Data Exchange (ETDEWEB)

    Zeballos, E. Cerron [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Crotty, I. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Hatzifotiadou, D. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Valverde, J. Lamas [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Univ. Louis Pasteur, Strasbourg (France); Neupane, S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Williams, M. C. S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Zichichi, A. [Univ. of Bologna, Bologna (Italy)

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  7. BEBC Big European Bubble Chamber

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    A view of the dismantling of the magnet of BEBC, the 3.7 m European Bubble Chamber : iron magnetic shielding ; lower and upper parts of the vacuum enclosure of the magnet; turbo-molecular vacuum pumps for the "fish-eye" windows; the two superconducting coils; a handling platform; the two cryostats suspended from the bar of the travelling crane which has a 170 ton carrying capacity. The chamber proper, not dismantled, is inside the shielding.

  8. Anterior chamber depth during hemodialysis

    Directory of Open Access Journals (Sweden)

    Gracitelli CPB

    2013-08-01

    Full Text Available Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of São Paulo – UNIFESP, São Paulo, Brazil Background: Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD because of anterior chamber depth changes during this therapy. Purpose: To evaluate anterior chamber depth and axial length in patients during HD sessions. Methods: A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth were measured using ultrasonic biometry, and these measures were evaluated at three different times during HD sessions. Body weight and blood pressure pre- and post-HD were also measured. Results: There was no difference in the axial length between the three measurements (P = 0.241. We observed a significantly decreased anterior chamber depth (P = 0.002 during HD sessions. Conclusion: Our results support the idea that there is a change in anterior chamber depth in HD sessions. Keywords: anterior chamber, hemodialysis, axial length, acute angle-closure glaucoma

  9. Wire pad chamber for LHCb muon system

    CERN Document Server

    Botchine, B; Lazarev, V A; Sagidova, N; Vorobev, A P; Vorobyov, A; Vorobyov, Alexei

    2000-01-01

    2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

  10. Assembly of Drift Tubes (DT) Chambers at CIEMAT (Madrid)

    CERN Multimedia

    Jesus Puerta-Pelayo

    2003-01-01

    The construction of muon drift tube chambers (DT) has been carried out in four different european institutes: Aachen (Germany), CIEMAT-Madrid (Spain), Legnaro and Turin (Italy), all of them following similar procedures and quality tests. Each chamber is composed by three or two independent units called superlayers, with four layers of staggered drift cells each. The assembly of a superlayer is a succesive glueing of aluminium plates and I-beams with electrodes previously attached, forming a rectangular and gas-tight volume. These pictures illustrate the various processes of material preparation, construction, equipment and assembly of full chambers at CIEMAT (Madrid).

  11. Cost advantage of dual-chamber versus single-chamber cardioverter-defibrillator implantation.

    Science.gov (United States)

    Goldberger, Zachary; Elbel, Brian; McPherson, Craig A; Paltiel, A David; Lampert, Rachel

    2005-09-06

    The purpose of this study was to determine the least expensive strategy for device selection in patients receiving implantable cardioverter-defibrillators (ICDs). Device cost for a single-chamber ICD is less than an atrioventricular (dual-chamber) ICD (AV-ICD); however, some patients without clinical need for AV-ICD at implantation might require a later upgrade, potentially offsetting the initial cost advantage of the single-chamber device. Decision analysis was used to estimate expected resource utilization costs of three alternative implantation strategies: 1) single-chamber device in all, with later upgrade to AV-ICD if needed; 2) initial implantation of an AV-ICD in all; and 3) targeted device selection on the basis of results of electrophysiologic testing (presence or absence of induced bradyarrhythmias or atrial arrhythmias). Clinical base estimates were obtained from retrospective review of all patients receiving ICDs between June 1997 and July 2001 at a single university hospital. Economic inputs were collected from national and single-center sources. In patients without other indications for electrophysiologic study (EPS), the expected per-person cost was least with the strategy of universal initial AV-ICD implantation (36,232 dollars) compared with initial single-chamber ICD/upgrade as needed (39,230 dollars) or EPS-guided selection (41,130 dollars). Sensitivity analyses demonstrated that universal AV-ICD implantation remained least expensive with upgrade rates as low as 10%. At a 5% upgrade rate, AV-ICD remained cheapest if the device cost-differential narrowed to 1,568 dollars. For patients undergoing EPS for risk assessment, EP-guided selection was least expensive. The strategy of universal AV-ICD implantation, which provides the benefits of dual-chamber capability while obviating any potential need for future upgrade, is the least costly strategy for most patient populations receiving ICDs.

  12. On Orbit Daytime Solar Heating Effects: A Comparison of Ground Chamber Arcing Results

    Science.gov (United States)

    Galofaro, J.; Vayner, B.; Ferguson, D.

    2004-01-01

    The purpose of the current experiment is to make direct comparisons between the arcing results obtained from the diffusion pumped vertical chamber and our newly renovated Teney vacuum chamber which is equipped with a cryogenic pump. Recall that the prior reported results obtained for the Vertical chamber were nominal at best, showing only a slight reduction in the arc rate after 5 heating cycles at the lower bias potentials and virtually no changes at high potential biases. It was concluded that the vertical chamber was unable to remove enough water vapor from the chamber to adequately test the arcing criterion. Because the cryo-pumped Teney chamber has a ten times better pumping speed, (40,000 liters per sec compared to 4,000 liters per sec for the diffusion pumped vertical chamber), a decision was made to retest that experiment in both the Teney and Vertical vacuum chambers. A comparison of the various data is presented with encouraging results.

  13. Emulsion Chamber Technology Experiment (ECT)

    Science.gov (United States)

    Gregory, John C.; Takahashi, Yoshiyuki

    1996-01-01

    The experimental objective of Emulsion Chamber Technology (ECT) was to develop space-borne emulsion chamber technology so that cosmic rays and nuclear interactions may subsequently be studied at extremely high energies with long exposures in space. A small emulsion chamber was built and flown on flight STS-62 of the Columbia in March 1994. Analysis of the several hundred layers of radiation-sensitive material has shown excellent post-flight condition and suitability for cosmic ray physics analysis at much longer exposures. Temperature control of the stack was 20 +/-1 C throughout the active control period and no significant deviations of temperature or pressure in the chamber were observed over the entire mission operations period. The unfortunate flight attitude of the orbiter (almost 90% Earth viewing) prevented any significant number of heavy particles (Z greater than or equal to 10) reaching the stack and the inverted flow of shower particles in the calorimeter has not allowed evaluation of absolute primary cosmic ray-detection efficiency nor of the practical time limits of useful exposure of these calorimeters in space to the level of detail originally planned. Nevertheless, analysis of the observed backgrounds and quality of the processed photographic and plastic materials after the flight show that productive exposures of emulsion chambers are feasible in low orbit for periods of up to one year or longer. The engineering approaches taken in the ECT program were proven effective and no major environmental obstacles to prolonged flight are evident.

  14. Anechoic Chambers: Aerospace Applications. (Latest Citations from the Aerospace Database)

    Science.gov (United States)

    1996-01-01

    The bibliography contains citations concerning the design, development, performance, and applications of anechoic chambers in the aerospace industry. Anechoic chamber testing equipment, techniques for evaluation of aerodynamic noise, microwave and radio antennas, and other acoustic measurement devices are considered. Shock wave studies on aircraft models and components, electromagnetic measurements, jet flow studies, and antenna radiation pattern measurements for industrial and military aerospace equipment are discussed. (Contains 50-250 citations and includes a subject term index and title list.)

  15. Immunoglobulin response to bluetongue virus soluble antigen in subcutaneous chambers.

    Science.gov (United States)

    Hajer, I; Jochim, M M; Lauerman, L H

    1977-06-01

    Group-specific antibodies were produced by inoculation of bluetongue virus soluble antigen into polyethylene chambers implanted subcutaneously in 8 rabbits and 2 sheep. For comparison, 5 rabbits and 1 sheep were inoculated intramuscularly with the soluble antigen in Freund's complete adjuvant. Antibodies present in the serum and chamber fluids were detected by the agar gel precipitin or serum-neutralization tests, qualitatively examined by immunoelectrophoresis and immunofluorescence, and quantitated by electroimmunodiffusion.

  16. Pre-evaluation of an ionization chamber for clinical radiotherapy dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Neves, Lucio P.; Perini, Ana P.; Xavier, Marcos; Caldas, Linda V.E., E-mail: mxavier@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2011-07-01

    This work presents some pre-operational tests for characterization of a new homemade ionization chamber developed at the Calibration Laboratory of Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP). This chamber was designed for use in radiotherapy dosimetry. To study the utilization of this chamber in radiotherapy, some tests were undertaken: short- and medium-term stabilities, saturation curve, recombination loss, polarity effect and leakage current. All results obtained in these tests were within the international recommendations. (author)

  17. Injection chamber test stands for optical testing of GDI injection systems in practically relevant engine conditions; Einspritzkammerpruefstaende fuer die optische Untersuchung von BDE-Einspritzduesen unter motorisch relevanten Bedingungen

    Energy Technology Data Exchange (ETDEWEB)

    Ipp, W.; Lindner, R.; Goldluecke, J.; Schmitz, I.; Leipertz, A. [Erlangen Univ. (Germany). Lehrstuhl fuer Technische Thermodynamik; Lutz, M. [Energie und Systemtechnik, ESYTEC GmbH, Erlangen (Germany)

    2005-07-01

    In GDI engines, the injection system has a significant effect on mixture formation, combustion and pollutant emissions. Therefore it is of basic interest to analyze the injection process at engine relevant conditions, for which contactless optical measurement techniques are particularly suitable. To investigate the specific behavior of the injection system it is required to separate the fuel propagation and evaporation processes from the influence of air motion and wall-interaction as it occurs inside the engine. For this purpose pressure vessels with optical accesses are used which are able to work at engine relevant conditions, regarding pressure as well as temperature. Beside this, for planning of an optical injection test bench, special demands have to be considered like the optimal and multifunctional use of optical measurement techniques, size, handling and safety, the utilization of existing resources as well as internal company regulations of the customer and last but not least, the costs. Considering these aspects the Department for Engineering Thermodynamics (LTT) of the University of Erlangen and the company ESYTEC Energie- und Systemtechnik GmbH have designed and constructed several optical test benches, some of them also for GDI systems. In this contribution the requirements for the optical investigation of GDI injection systems are discussed and an example of an already working test rig is shown. (orig.)

  18. A Temperature-Controlled Chamber Based on Vortex Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Krider, John; Nguyen, Hogan; /Fermilab

    2007-11-01

    We describe the construction and performance of a temperature-controlled chamber, based on a 'vortex' cooler. The chamber is capable of operation between room temperature and -42 C. The only nontrivial infrastructure requirement is dry compressed gas at 100 psi and 8 cfm. The chamber is economical, easy to operate and to build using commercially available parts. Since the refrigerant is compressed air, the chamber has minimal environmental impact. It does not generate mechanical vibrations nor electrical noise. It is suitable for testing electronically sensitive and low-power electronics at cold temperatures. We measured the reserve cooling capacity of the cold plate to be 17 watts at -27 C. At the limiting temperature of -42 C, reserve cooling power reduces to zero.

  19. Continuous flow, explosives vapor generator and sensor chamber

    Science.gov (United States)

    Collins, Greg E.; Giordano, Braden C.; Sivaprakasam, Vasanthi; Ananth, Ramagopal; Hammond, Mark; Merritt, Charles D.; Tucker, John E.; Malito, Michael; Eversole, Jay D.; Rose-Pehrsson, Susan

    2014-05-01

    A novel liquid injection vapor generator (LIVG) is demonstrated that is amenable to low vapor pressure explosives, 2,4,6-trinitrotoluene and hexahydro-1,3,5-trinitro-1,3,5-triazine. The LIVG operates in a continuous manner, providing a constant and stable vapor output over a period of days and whose concentration can be extended over as much as three orders of magnitude. In addition, a large test atmosphere chamber attached to the LIVG is described, which enables the generation of a stable test atmosphere with controllable humidity and temperature. The size of the chamber allows for the complete insertion of testing instruments or arrays of materials into a uniform test atmosphere, and various electrical feedthroughs, insertion ports, and sealed doors permit simple and effective access to the sample chamber and its vapor.

  20. A dual deformable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    There is disclosed an arrangement for measuring the effectiveness of a shielding material against electromagnetic fields. The arrangement comprises a first and a second reverberation chamber sharing a common wall. The common wall is partly made of the shielding material. A first antenna is arranged

  1. LEP vacuum chamber, early prototype

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The same vacuum chamber as in 7810256, read the detailed description there. Here, the 4 strip-shaped ion-getter pumps are poised at the entrance to their slots. Ion-getter pumps were not retained, thermal getter pumps were chosen instead (see 8301153 and 8305170).

  2. Bubble chamber: colour enhanced tracks

    CERN Multimedia

    1998-01-01

    This artistically-enhanced image of real particle tracks was produced in the Big European Bubble Chamber (BEBC). Liquid hydrogen is used to create bubbles along the paths of the particles as a piston expands the medium. A magnetic field is produced in the detector causing the particles to travel in spirals, allowing charge and momentum to be measured.

  3. DELPHI's Ring Imaging Cherenkov Chamber

    CERN Multimedia

    1989-01-01

    The hundreds of mirrors around this Ring Imaging Cherenkov Chamber reflect cones of light created by fast moving particles to a detector. The velocity of a particle can be measured by the size of the ring produced on the detector. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  4. Microstrip gas chambers on implanted substrates

    Energy Technology Data Exchange (ETDEWEB)

    Pallares, A. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Barthe, S. [Laboratoire PHASE (UPR 292 du CNRS), 23 rue du Loess, BP 28, 67037 Strasbourg Cedex 2 (France); Bergtold, A.M. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Brom, J.M. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Cailleret, J. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Christophel, E. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Coffin, J. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Eberle, H. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Fang, R. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Fontaine, J.C. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Geist, W. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Kachelhoffer, T. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Levy, J.M. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Mack, V. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Schunck, J.P. [Laboratoire PHASE (UPR 292 du CNRS), 23 rue du Loess, BP 28, 67037 Strasbourg Cedex 2 (France); Sigward, M.H. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires

    1995-12-11

    We have studied the performance of several Microstrip Gas Chamber (MSGC) prototypes made on standard Desag D263 boron implanted glass. The purpose of the implantation is to reduce the surface resistance. The long term stability of this implantation has been measured under applied bias voltage. Comparative tests have been carried out on prototypes made on implanted and unimplanted detectors under electron ({sup 90}Sr) and X-ray (8 keV) irradiation. The total dose was approximately 7 mC/cm. (orig.).

  5. Resistive Plate Chambers for Imaging Calorimetry - the DHCAL

    CERN Document Server

    Repond, Jose

    2014-01-01

    The DHCAL, the Digital Hadron Calorimeter, is a prototype calorimeter based on Resistive Plate Chambers (RPCs). The design emphasizes the imaging capabilities of the detector in an effort to optimize the calorimeter for the application of Particle Flow Algorithms (PFAs) to the reconstruction of hadronic jet energies in a colliding beam environment. The readout of the chambers is segmented into 1 x 1 cm2 pads, each read out with a 1-bit (single threshold) resolution. The prototype with approximately 500,000 readout channels underwent extensive testing in both the Fermilab and CERN test beams. This talk presents preliminary findings from the analysis of data collected at the test beams.

  6. Resistive Plate Chambers for imaging calorimetry — The DHCAL

    Science.gov (United States)

    Repond, J.

    2014-09-01

    The DHCAL — the Digital Hadron Calorimeter — is a prototype calorimeter based on Resistive Plate Chambers (RPCs). The design emphasizes the imaging capabilities of the detector in an effort to optimize the calorimeter for the application of Particle Flow Algorithms (PFAs) to the reconstruction of hadronic jet energies in a colliding beam environment. The readout of the chambers is segmented into 1 × 1 cm2 pads, each read out with a 1-bit (single threshold) resolution. The prototype with approximately 500,000 readout channels underwent extensive testing in both the Fermilab and CERN test beams. This talk presents preliminary findings from the analysis of data collected at the test beams.

  7. Herds of methane chambers grazing bubbles

    Science.gov (United States)

    Grinham, Alistair; Dunbabin, Matthew

    2014-05-01

    Water to air methane emissions from freshwater reservoirs can be dominated by sediment bubbling (ebullitive) events. Previous work to quantify methane bubbling from a number of Australian sub-tropical reservoirs has shown that this can contribute as much as 95% of total emissions. These bubbling events are controlled by a variety of different factors including water depth, surface and internal waves, wind seiching, atmospheric pressure changes and water levels changes. Key to quantifying the magnitude of this emission pathway is estimating both the bubbling rate as well as the areal extent of bubbling. Both bubbling rate and areal extent are seldom constant and require persistent monitoring over extended time periods before true estimates can be generated. In this paper we present a novel system for persistent monitoring of both bubbling rate and areal extent using multiple robotic surface chambers and adaptive sampling (grazing) algorithms to automate the quantification process. Individual chambers are self-propelled and guided and communicate between each other without the need for supervised control. They can maintain station at a sampling site for a desired incubation period and continuously monitor, record and report fluxes during the incubation. To exploit the methane sensor detection capabilities, the chamber can be automatically lowered to decrease the head-space and increase concentration. The grazing algorithms assign a hierarchical order to chambers within a preselected zone. Chambers then converge on the individual recording the highest 15 minute bubbling rate. Individuals maintain a specified distance apart from each other during each sampling period before all individuals are then required to move to different locations based on a sampling algorithm (systematic or adaptive) exploiting prior measurements. This system has been field tested on a large-scale subtropical reservoir, Little Nerang Dam, and over monthly timescales. Using this technique

  8. A new fission chamber dedicated to Prompt Fission Neutron Spectra measurements

    Energy Technology Data Exchange (ETDEWEB)

    Taieb, J.; Laurent, B., E-mail: benoit.laurent@cea.fr; Bélier, G.; Sardet, A.; Varignon, C.

    2016-10-11

    New fission chambers dedicated to Prompt Fission Neutron Spectra measurements with the time-of-flight technique have been developed. The actinide mass embedded in the chamber was maximized, while the alpha-fission discrimination and the time resolution were optimized. Moreover, to reduce the neutron background and spectra distortions, neutron scattering with the materials were minimized by the choice of material and structure. These chambers were then tested and validated during tests and in-beam experiments.

  9. Technology developments for thrust chambers of future launch vehicle liquid rocket engines

    Science.gov (United States)

    Immich, H.; Alting, J.; Kretschmer, J.; Preclik, D.

    2003-08-01

    In this paper an overview of recent technology developments for thrust chambers of future launch vehicle liquid rocket engines at Astrium, Space Infrastructure Division (SI), is shown. The main technology. developments shown in this paper are: Technologies Technologies for enhanced heat transfer to the coolant for expander cycle engines Advanced injector head technologies Advanced combustion chamber manufacturing technologies. The main technologies for enhanced heat transfer investigated by subscale chamber hot-firing tests are: Increase of chamber length Hot gas side ribs in the chamber Artificially increased surface roughness. The developments for advanced injector head technologies were focused on the design of a new modular subscale chamber injector head. This injector head allows for an easy exchange of different injection elements: By this, cost effective hot-fire tests with different injection element concepts can be performed. The developments for advanced combustion chamber manufacturing technologies are based on subscale chamber tests with a new design of the Astrium subscale chamber. The subscale chamber has been modified by introduction of a segmented cooled cylindrical section which gives the possibility to test different manufacturing concepts for cooled chamber technologies by exchanging the individual segments. The main technology efforts versus advanced manufacturing technologies shown in this paper are: Soldering techniques Thermal barrier coatings for increased chamber life. A new technology effort is dedicated especially to LOX/Hydrocarbon propellant combinations. Recent hot fire tests on the subscale chamber with Kerosene and Methane as fuel have already been performed. A comprehensive engine system trade-off between the both propellant combinations (Kerosene vs. Methane) is presently under preparation.

  10. Metal explosion chambers: designing, manufacturing, application

    Science.gov (United States)

    Stoyanovskii, O. I.; Zlobin, B. S.; Shtertser, A. A.; Meshcheryakov, Y. P.

    2017-10-01

    Designing of explosion chambers is based on research investigations of the chamber body stress-strain state, which is determined by numerical computation and experimentally by the strain gage technique. Studies show that chamber bottoms are the most loaded elements, and maximal stresses arise in chamber poles. Increasing the shell thickness around poles by welding-in an insert is a simple and saving way to solve this problem. There are structural solutions, enabling reliable hermetic closure and preventing leakage of detonation products from the chamber. Explosion chambers are employed in scientific research and in different industrial applications: explosive welding and hardening, synthesis of new materials, disposal of expired ammunition, and etc.

  11. Growing and Analyzing Biofilms in Flow Chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic...... conditions, and the environment can be carefully controlled and easily changed. The protocols in this unit include construction of the flow chamber and the bubble trap, assembly and sterilization of the flow chamber system, inoculation of the flow chambers, running of the system, image capture and analysis...

  12. Energy Loss to Coaxial Vacuum Chambers in LEP and LHC

    CERN Document Server

    Gluckstern, R L

    1996-01-01

    In many hig-energy storage rings the beam chamber is connected to a separate pump chamber by a metallic wall with many holes or slots whic permits passage of the rest gas. In LEP, the pump chamber contains a metallic 'negstrip' pump, and thereby becomes a coazial transmission line. Also in LHC, a coaxial line is formed by the 'liner' and the surrounding cold vacuum chamber which it shields from heating by sznchrotron radiation. Since the phase velocity of electro-magnetic fields in a coax line is close to light velocity, the fields will be almost in sznchronism with the particle beam and the pump chamber, which may result in a large resistive impedance and could lead to isntability, loss of beam energy, and excessive heating of the chamber walls. Here we estimate the rate of field buildup analytically, and in a subsequent report we will compare these results with numerical computations using 3-D computer codes. The results are tested for diagnostic purposes on a 'slot coupler' with short and wide holes design...

  13. Oxide Protective Coats for Ir/Re Rocket Combustion Chambers

    Science.gov (United States)

    Fortini, Arthur; Tuffias, Robert H.

    2003-01-01

    An improved material system has been developed for rocket engine combustion chambers for burning oxygen/ hydrogen mixtures or novel monopropellants, which are highly oxidizing at operating temperatures. The baseline for developing the improved material system is a prior iridium/rhenium system for chambers burning nitrogen tetroxide/monomethyl hydrazine mixtures, which are less oxidizing. The baseline combustion chamber comprises an outer layer of rhenium that provides structural support, plus an inner layer of iridium that acts as a barrier to oxidation of the rhenium. In the improved material system, the layer of iridium is thin and is coated with a thermal fatigue-resistant refractory oxide (specifically, hafnium oxide) that serves partly as a thermal barrier to decrease the temperature and thus the rate of oxidation of the rhenium. The oxide layer also acts as a barrier against the transport of oxidizing species to the surface of the iridium. Tests in which various oxygen/hydrogen mixtures were burned in iridium/rhenium combustion chambers lined with hafnium oxide showed that the operational lifetimes of combustion chambers of the improved material system are an order of magnitude greater than those of the baseline combustion chambers.

  14. LEP vacuum chamber, early prototype

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The structure of LEP, with long bending magnets and little access to the vacuum chamber between them, required distributed pumping. This is an early prototype for the LEP vacuum chamber, made from extruded aluminium. The main opening is for the beam. The small channel to the right is for cooling water, to carry away the heat deposited by the synchroton radiation from the beam. The 4 slots in the channel to the left house the strip-shaped ion-getter pumps (see 7810255). The ion-getter pumps depended on the magnetic field of the bending magnets, too low at injection energy for the pumps to function well. Also, a different design was required outside the bending magnets. This design was therefore abandoned, in favour of a thermal getter pump (see 8301153 and 8305170).

  15. Development of multiwire proportional chambers

    CERN Multimedia

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  16. Aging Investigation of CMS EMU Prototype Chambers

    CERN Document Server

    Ferguson*, T; Krivshich, Anatoli; Kuznetsova, Ekaterina; Lobachev, Evgeny; Mitselmakher, Guenakh; Schipunov, L

    1999-01-01

    The aging investigation results of CMS EMU prototype chambers are presented. Aging tests under sustained irradiation by a 90Sr 2 Ci were performed with three working gas mixtures Ar( 30%)+CO2( 50%)+CF4( 20%), Ar( 30%)+CO2( 70%) and Ar( 40%)+CO2( 50%)+CF4( 10%). For Ar( 30%)+CO2( 50%)+CF4( 20%) mixture gas gain reduction was not observed up to the accumulated charge Q = 13.56 C/cm. However, the dark current in the chamber was noticeable starting already from Q = 2 C/cm. The absence of the CF4 ( in the Ar/CO2 gas mixture) caused fast aging deterioration, and Q = 0.2 C/cm was enough to obtain 50% of the gas gain reduction. In the test with Ar( 40%)+CO2( 50%)+CF4( 10%) mixture the gas gain reduction and the dark current increase were not observed up to Q = 13.35 C/cm. Reduction of the gas flow rate to 0.1 volume per day caused 50% of the gain decrease due to the gas pollution by fragments of dissociated gas molecules. The gain restored after switching back to the 1 volume per day flow rate. Studies with electroni...

  17. Characterization of a free air ionization chamber for low energies

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Natalia F.; Xavier, Marcos; Vivolo, Vitor; Caldas, Linda V.E., E-mail: nsilva@ipen.br, E-mail: mxavier@ipen.br, E-mail: vivolo@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Free air ionization chambers are used by most primary metrology laboratories as primary standards of the quantities air kerma and exposure in X-ray beams. The free air ionization chamber for low energies of the Calibration Laboratory (LCI) of IPEN showed in a characterization test a problem in the set responsible for the variation of its sensitive volume. After a modification in the support of the micrometers used for the movement of the internal cylinder and the establishment of a new alignment system protocol, the tests were redone. The objective of this work was to present the results obtained in the new condition. (author)

  18. Design of a Fully Anechoic Chamber

    OpenAIRE

    Rusz, Roman

    2015-01-01

    This thesis deals with fully anechoic chamber design. The main aim of this thesis is to design fully anechoic chamber according to acoustics laws and customers (Honeywell’s) requirements. The fully anechoic chamber will be used for measuring sound and vibration quantities. This work is divided into two main parts. The first part deals with the general anechoic chamber theory and all its related design aspects. The second part, practical part, focus on specific design according to requirements...

  19. Liquid rocket combustion chamber acoustic characterization

    Directory of Open Access Journals (Sweden)

    Cândido Magno de Souza

    2010-09-01

    Full Text Available Over the last 40 years, many solid and liquid rocket motors have experienced combustion instabilities. Among other causes, there is the interaction of acoustic modes with the combustion and/or fluid dynamic processes inside the combustion chamber. Studies have been showing that, even if less than 1% of the available energy is diverted to an acoustic mode, combustion instability can be generated. On one hand, this instability can lead to ballistic pressure changes, couple with other propulsion systems such as guidance or thrust vector control, and in the worst case, cause motor structural failure. In this case, measures, applying acoustic techniques, must be taken to correct/minimize these influences on the combustion. The combustion chamber acoustic behavior in operating conditions can be estimated by considering its behavior in room conditions. In this way, acoustic tests can be easily performed, thus identifying the cavity modes. This paper describes the procedures to characterize the acoustic behavior in the inner cavity of four different configurations of a combustion chamber. Simple analytical models are used to calculate the acoustic resonance frequencies and these results are compared with acoustic natural frequencies measured at room conditions. Some comments about the measurement procedures are done, as well as the next steps for the continuity of this research. The analytical and experimental procedures results showed good agreement. However, limitations on high frequency band as well as in the identification of specific kinds of modes indicate that numerical methods able to model the real cavity geometry and an acoustic experimental modal analysis may be necessary for a more complete analysis. Future works shall also consider the presence of passive acoustic devices such as baffles and resonators capable of introducing damping and avoiding or limiting acoustic instabilities.

  20. Vacuum chamber at intersection I-6

    CERN Multimedia

    1971-01-01

    The vacuum chamber at intersection region I-6, one of these where experiments in colliding-beam physics will be taking place. The "wheels" prevent the thin wall (1.5 mm) of the chamber from collapsing. The chamber is equipped with heating tapes and its wrapped in thermal insulation. Residual gas pressure at this and other similar regions is around 10_11.

  1. Making a Fish Tank Cloud Chamber

    Science.gov (United States)

    Green, Frances

    2012-01-01

    The cloud chambers described here are large, made from readily available parts, simple to set up and always work. With no source in the chamber, background radiation can be observed. A large chamber means that a long rod containing a weakly radioactive material can be introduced, increasing the chance of seeing decays. Details of equipment and…

  2. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...

  3. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic cond...

  4. Thermal comfort of dual-chamber ski gloves

    Science.gov (United States)

    Dotti, F.; Colonna, M.; Ferri, A.

    2017-10-01

    In this work, the special design of a pair of ski gloves has been assessed in terms of thermal comfort. The glove 2in1 Gore-Tex has a dual-chamber construction, with two possible wearing configurations: one called “grip” to maximize finger flexibility and one called “warm” to maximize thermal insulation in extremely cold conditions. The dual-chamber gloves has been compared with two regular ski gloves produced by the same company. An intermittent test on a treadmill was carried out in a climatic chamber: it was made of four intense activity phases, during which the volunteer ran at 9 km/h on a 5% slope for 4 minutes, spaced out by 5-min resting phases. Finger temperature measurements were compared with the thermal sensations expressed by two volunteers during the test.

  5. Static and wind tunnel near-field/far-field jet noise measurements from model scale single-flow base line and suppressor nozzles. Summary report. [conducted in the Boeing large anechoic test chamber and the NASA-Ames 40by 80-foot wind tunnel

    Science.gov (United States)

    Jaeck, C. L.

    1977-01-01

    A test program was conducted in the Boeing large anechoic test chamber and the NASA-Ames 40- by 80-foot wind tunnel to study the near- and far-field jet noise characteristics of six baseline and suppressor nozzles. Static and wind-on noise source locations were determined. A technique for extrapolating near field jet noise measurements into the far field was established. It was determined if flight effects measured in the near field are the same as those in the far field. The flight effects on the jet noise levels of the baseline and suppressor nozzles were determined. Test models included a 15.24-cm round convergent nozzle, an annular nozzle with and without ejector, a 20-lobe nozzle with and without ejector, and a 57-tube nozzle with lined ejector. The static free-field test in the anechoic chamber covered nozzle pressure ratios from 1.44 to 2.25 and jet velocities from 412 to 594 m/s at a total temperature of 844 K. The wind tunnel flight effects test repeated these nozzle test conditions with ambient velocities of 0 to 92 m/s.

  6. Low-Cost, High-Performance Combustion Chamber

    Science.gov (United States)

    Fortini, Arthur J.

    2015-01-01

    Ultramet designed and fabricated a lightweight, high-temperature combustion chamber for use with cryogenic LOX/CH4 propellants that can deliver a specific impulse of approx.355 seconds. This increase over the current 320-second baseline of nitrogen tetroxide/monomethylhydrazine (NTO/MMH) will result in a propellant mass decrease of 55 lb for a typical lunar mission. The material system was based on Ultramet's proven oxide-iridium/rhenium architecture, which has been hot-fire tested with stoichiometric oxygen/hydrogen for hours. Instead of rhenium, however, the structural material was a niobium or tantalum alloy that has excellent yield strength at both ambient and elevated temperatures. Phase I demonstrated alloys with yield strength-to-weight ratios more than three times that of rhenium, which will significantly reduce chamber weight. The starting materials were also two orders of magnitude less expensive than rhenium and were less expensive than the C103 niobium alloy commonly used in low-performance engines. Phase II focused on the design, fabrication, and hot-fire testing of a 12-lbf thrust class chamber with LOX/CH4, and a 100-lbf chamber for LOX/CH4. A 5-lbf chamber for NTO/MMH also was designed and fabricated.

  7. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London...

  8. COLDDIAG: A Cold Vacuum Chamber for Diagnostics

    CERN Document Server

    Casalbuoni, S; Gerstl, S; Grau, A W; Hagelstein, M; Saez de Jauregui, D; Boffo, C; Sikler, G; Baglin, V; Cox, M P; Schouten, J C; Cimino, R; Commisso, M; Spataro, B; Mostacci, A; Wallen, E J; Weigel, R; Clarke, J; Scott, D; Bradshaw, T; Jones, R; Shinton, I

    2011-01-01

    One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.

  9. Promoted-Combustion Chamber with Induction Heating Coil

    Science.gov (United States)

    Richardson, Erin; Hagood, Richard; Lowery, Freida; Herald, Stephen

    2006-01-01

    prevent heating of the base of the chamber during use. A sapphire cylinder protects the coil against slag generated during an experiment. The induction coil is energized by a 6-kW water-cooled power supply operating at a frequency of 400 kHz. The induction coil is part of a parallel-tuned circuit, the tuning of which is used to adjust the coupling of power to the specimen. The chamber is mounted on a test stand along with pumps, valves, and plumbing for transferring pressurized gas into and out of the chamber. In addition to multiple video cameras aimed through the windows encircling the chamber, the chamber is instrumented with gauges for monitoring the progress of an experiment. One of the gauges is a dual-frequency infrared temperature transducer aimed at the specimen through one window. Chamber operation is achieved via a console that contains a computer running apparatus-specific software, a video recorder, and real-time video monitors. For safety, a blast wall separates the console from the test stand.

  10. Design and construction of an inexpensive homemade plant growth chamber.

    Science.gov (United States)

    Katagiri, Fumiaki; Canelon-Suarez, Dario; Griffin, Kelsey; Petersen, John; Meyer, Rachel K; Siegle, Megan; Mase, Keisuke

    2015-01-01

    Plant growth chambers produce controlled environments, which are crucial in making reproducible observations in experimental plant biology research. Commercial plant growth chambers can provide precise controls of environmental parameters, such as temperature, humidity, and light cycle, and the capability via complex programming to regulate these environmental parameters. But they are expensive. The high cost of maintaining a controlled growth environment is often a limiting factor when determining experiment size and feasibility. To overcome the limitation of commercial growth chambers, we designed and constructed an inexpensive plant growth chamber with consumer products for a material cost of $2,300. For a comparable growth space, a commercial plant growth chamber could cost $40,000 or more. Our plant growth chamber had outside dimensions of 1.5 m (W) x 1.8 m (D) x 2 m (H), providing a total growth area of 4.5 m2 with 40-cm high clearance. The dimensions of the growth area and height can be flexibly changed. Fluorescent lights with large reflectors provided a relatively spatially uniform photosynthetically active radiation intensity of 140-250 μmoles/m2/sec. A portable air conditioner provided an ample cooling capacity, and a cooling water mister acted as a powerful humidifier. Temperature, relative humidity, and light cycle inside the chamber were controlled via a z-wave home automation system, which allowed the environmental parameters to be monitored and programmed through the internet. In our setting, the temperature was tightly controlled: 22.2°C±0.8°C. The one-hour average relative humidity was maintained at 75%±7% with short spikes up to ±15%. Using the interaction between Arabidopsis and one of its bacterial pathogens as a test experimental system, we demonstrate that experimental results produced in our chamber were highly comparable to those obtained in a commercial growth chamber. In summary, our design of an inexpensive plant growth chamber

  11. Design and construction of an inexpensive homemade plant growth chamber.

    Directory of Open Access Journals (Sweden)

    Fumiaki Katagiri

    Full Text Available Plant growth chambers produce controlled environments, which are crucial in making reproducible observations in experimental plant biology research. Commercial plant growth chambers can provide precise controls of environmental parameters, such as temperature, humidity, and light cycle, and the capability via complex programming to regulate these environmental parameters. But they are expensive. The high cost of maintaining a controlled growth environment is often a limiting factor when determining experiment size and feasibility. To overcome the limitation of commercial growth chambers, we designed and constructed an inexpensive plant growth chamber with consumer products for a material cost of $2,300. For a comparable growth space, a commercial plant growth chamber could cost $40,000 or more. Our plant growth chamber had outside dimensions of 1.5 m (W x 1.8 m (D x 2 m (H, providing a total growth area of 4.5 m2 with 40-cm high clearance. The dimensions of the growth area and height can be flexibly changed. Fluorescent lights with large reflectors provided a relatively spatially uniform photosynthetically active radiation intensity of 140-250 μmoles/m2/sec. A portable air conditioner provided an ample cooling capacity, and a cooling water mister acted as a powerful humidifier. Temperature, relative humidity, and light cycle inside the chamber were controlled via a z-wave home automation system, which allowed the environmental parameters to be monitored and programmed through the internet. In our setting, the temperature was tightly controlled: 22.2°C±0.8°C. The one-hour average relative humidity was maintained at 75%±7% with short spikes up to ±15%. Using the interaction between Arabidopsis and one of its bacterial pathogens as a test experimental system, we demonstrate that experimental results produced in our chamber were highly comparable to those obtained in a commercial growth chamber. In summary, our design of an inexpensive plant

  12. A silicon microstrip gas chamber

    Energy Technology Data Exchange (ETDEWEB)

    Van der Marel, J. (Radiation Technology Group, Faculty of Applied Physics, Delft Univ. of Tech. (Netherlands)); Van den Bogaard, A. (Delft Inst. of Microelectronics and Submicrotechnology, Delft Univ. of Tech. (Netherlands)); Van Eijk, C.W.E. (Radiation Technology Group, Faculty of Applied Physics, Delft Univ. of Tech. (Netherlands)); Hollander, R.W. (Radiation Technology Group, Faculty of Applied Physics, Delft Univ. of Tech. (Netherlands)); Okx, W.J.C. (Radiation Technology Group, Faculty of Applied Physics, Delft Univ. of Tech. (Netherlands)); Sarro, P.M. (Delft Inst. of Microelectronics and Submicrotechnology, Delft Univ. of Tech. (Netherlands))

    1994-09-01

    We are manufacturing microstrip gas chambers (MSGC) on silicon with an insulating SiO[sub 2] layer. To study the effect of the sheet resistance of the SiO[sub 2] on the operation of the detector several processes to modify the SiO[sub 2] layer have been investigated: ion implantation, boron and phosphorus diffusion, phosphosilicate glass evaporation and polycrystalline silicon deposition. The dependence of the gas gain on the potentials of the different electrodes and the long term stability have been studied. ((orig.))

  13. Pupillary block glaucoma following implantation of a posterior chamber pseudophakos in the anterior chamber.

    Directory of Open Access Journals (Sweden)

    Mandal Anil

    2002-01-01

    Full Text Available Pupillary block glaucoma is a common complication of cataract surgery, especially following anterior chamber intraocular lens implantation. We report a case of pupillary block glaucoma with a posterior chamber IOL that was implanted in the anterior chamber following a complicated extracapsular cataract extraction. The case was successfully managed by explantation of the posterior chamber lens, anterior vitrectomy, peripheral iridectomy and secondary anterior chamber intraocular lens implantation. The intraocular pressure was controlled with a single topical antiglaucoma medication.

  14. Limits to Drift Chamber Resolution

    CERN Document Server

    Riegler, Werner

    1998-01-01

    ATLAS (A Large Toroidal LHC Apparatus) will be a general-purpose experiment at the Large Hadron Collider that will be operational at CERN in the year 2004. The ATLAS muon spectrometer aims for a momentum resolution of 10% for a transverse momentum of pT=1TeV. The precision tracking devices in the muon system will be high pressure drift tubes (MDTs) with a single wire resolution of 1100 chambers covering an area of ≈ 2500m2. The high counting rates in the spectrometer as well as the aim for excellent spatial resolution and high efficiency put severe constraints on the MDT operating parameters. This work describes a detailed study of all the resolution limiting factors in the ATLAS environment. A ’full chain’ simulation of the MDT response to photons and charged particles as well as quantitative comparisons with measurements was performed. The good agreement between simulation and measurements resulted in a profound understanding of the drift chamber processes and the individual contributions to the spat...

  15. Physicist makes muon chamber sing

    CERN Document Server

    2007-01-01

    This Monitored Drift Tube detector, consisting of argon-CO2-filled aluminium tubes with a wire down the centre of each, will track muons in ATLAS; Tiecke used a single tube from one of these detectors to create the pipes in his organ. Particle physicists can make good musicians; but did you know particle detectors can make good music? That's what NIKHEF physicist Henk Tiecke learned when he used pipes cut from the ATLAS Monitored Drift Tube detector (MDT) to build his own working Dutch-style barrel organ in the autumn of 2005. 'I like to work with my hands,' said Tiecke, who worked as a senior physicist at NIKHEF, Amsterdam, on ZEUS until his retirement last summer. Tiecke had already constructed his barrel organ when he visited some colleagues in the ATLAS muon chambers production area at Nikhef in 2005. He noticed that the aluminium tubes they were using to build the chambers were about three centimetres in diameter-just the right size for a pipe in a barrel organ. 'The sound is not as nice as from wooden...

  16. Comparison of Channel Emulation Techniques in Multiprobe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Llorente, Ines Carton; Fan, Wei; Nielsen, Jesper Ødum

    2015-01-01

    This paper compares two different techniques for channel emulation in multiprobe anechoic chamber based setups, which is a candidate solution for the standardization of MIMO OTA performance testing of mobile devices. The comparison is performed via simulations of the field distribution, temporal...

  17. Electromagnetic Field in Anechoic and EMC Chambers - Part I - Modelling

    Directory of Open Access Journals (Sweden)

    P. Pechac

    2000-04-01

    Full Text Available Anechoic and EMC chamber at the CTU in Prague was designed and used fora variety of antenna measurements and EMI testing. Due to differentmeasurement methods (near field, far field, compact range, and EMImeasurement applied in the laboratory, different simulations wereperformed during the design process.

  18. Rician Channel Modeling for Multiprobe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Hentilä, Lassi

    2014-01-01

    This paper discusses over the air (OTA) testing for multiple input multiple output (MIMO) capable terminals, with emphasis on modeling Rician channel models in the multi-probe anechoic chamber setups. A technique to model Rician channels is proposed. The line-of-sight (LOS) component...

  19. Electromagnetic Field in Anechoic and EMC Chambers - Part I - Modelling

    OpenAIRE

    Mazanek, M.; Klepal, M.; Pechač, Pavel

    2000-01-01

    Anechoic and EMC chamber at the CTU in Prague was designed and used for a variety of antenna measurements and EMI testing. Due to different measurement methods (near field, far field, compact range, and EMI measurement) applied in the laboratory, different simulations were performed during the design process.

  20. Transfer Chamber for DBD Surface Treatment and Analysis

    Science.gov (United States)

    Faust, Jessica; Gershman, Sophia; Daniels, Ryan

    2012-10-01

    Materials that are hydrophobic, smooth, and have low surface tension lead to poor adhesion for printing and coating. Surface modification using atmospheric pressure dielectric barrier discharge (DBD) improves adhesion by activating the surface, increasing its roughness and functionalizing. We have constructed and tested a DBD discharge system that uses a 15kV, 800-1350Hz pulsed dc source and a mixture of gasses at 300-600Torr. Treated surfaces are studied using X-ray photoelectron spectroscopy, Auger electron spectroscopy, and other methods that require high vacuum environment. We designed a portable transfer chamber to move the sample from the atmospheric pressure treatment chamber to a high vacuum surface analysis chamber with minimal interaction with the environment. The transfer chamber was designed to meet the specific requirements of each system; a bellows drive and sample holder to manually move the sample into the transfer chamber; the ability to fill with pure nitrogen gas to prevent contamination of the sample surface; constructed to withstand a range of pressures from 300 to 10-8Torr; the ability to connect compatibly with each system. Proper surface characterization of the sample is crucial to designing an effective treatment system.

  1. Sag Compensation System for Assembly of MDT-Chambers for the ATLAS Experiment

    CERN Document Server

    Barashkou, A V; Chepurnov, V F; Evtoukhovitch, P G; Glonti, G L; Gongadze, A L; Ilyushenka, Y N; Kotov, S A; Kruchonak, V G; Tskhadadze, E G

    2005-01-01

    The description of a system of the devices created for compensation of the gravitational deflection of the drift chamber during its assembly is presented. By means of this system during stage-by-stage gluing of layers of tube drift detectors to the chamber the transversal deflection considerably decreases and by that high accuracy of mutual position of separate tubes is provided. The devices were applied at assembly of 74 MDT-chambers of the ATLAS experiment. Design values of deformation of the chambers as well as the results of measurement of transversal deflections obtained during the assembly with the use of the system of sag compensation are given. Testing of chambers on the X-ray tomograph at CERN has shown that the accuracy of the positions of separate signal wires inside the assembled chambers is within the limits of the required 20 $\\mu$m.

  2. Elimination of High-Frequency Combustion Instability in the Fastrac Engine Thrust Chamber

    Science.gov (United States)

    Rocker, Marvin; Nesman, Tomas E.

    1999-01-01

    A series of tests were conducted to stabilize the combustion of the Fastrac engine thrust chamber. The first few stability tests resulted in unstable combustion due ineffective acoustic cavity designs. The thrust chamber exhibited unstable combustion in the first-tangential mode and its harmonics. Combustion was stabilized by increasing the volume of the acoustic cavities and by plugging the dump-cooling orifices so that the cavities were uncooled. Although the first few stability tests resulted in unstable combustion, prior and subsequent long-duration performance tests of the Fastrac thrust chamber were spontaneously stable. Stability considerations during the injector faceplate design were based on the Hewitt correlation.

  3. Bond durability of contemporary adhesive systems to pulp chamber dentin

    Science.gov (United States)

    Ayar, Muhammet Kerim

    2015-01-01

    Abstract Objective: The purpose of this study was to evaluate long-term bond strengths of dentin adhesive systems, which include one-step self-etch adhesive systems (Optibond All-in-one, Kerr; Adper Prompt L-POP, 3 M ESPE), a three-step etch-and-rinse adhesive (Optibond FL, Kerr) and two-step self-etch adhesive (AdheSE Bond, Ivoclar), applied to pulp chamber dentin surfaces after 12-month water storage by using microtensile bond strength (µTBS) test. Materials and methods: Dentin adhesive systems were applied to unprepared pulp chamber dentin surfaces according to manufacturer’s directions, respectively (n = 5). After applying adhesive systems, composite buildups were done incrementally. Bond strengths to pulp chamber dentin surfaces were determined using µTBS test after water storage for 24 h and 12 month. Kruskal–Wallis analysis and Mann–Whitney U-test for pairwise comparisons were used to determine statistical differences in µTBS between the groups at a significance level of 5%. Results: There were no significant differences in µTBS between storage periods for tested adhesives regardless adhesive class. Conclusion: Bond durability of tested adhesive systems, including one-bottle self-etch adhesives with pulp chamber dentin surfaces, may be considered stable after 12-month water storage. Therefore, one-step self-etch, also called “user-friendly” adhesives may perform and traditional three-step etch-and-rinse adhesives in the long-term when used for bonding to pulp chamber dentin surfaces. PMID:28642905

  4. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Palmans, H. [Ghent Univ. (Belgium). Dept. of Biomedical Physics; Verhaegen, F.

    1995-12-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire`s multiple scattering theory and Vavilov`s energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program`s accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented.

  5. Performance of single chamber biocatalyzed electrolysis with different types of ion exchange membranes

    NARCIS (Netherlands)

    Rozendal, R.A.; Hamelers, H.V.M.; Molenkamp, R.J.; Buisman, C.J.N.

    2007-01-01

    In this paper hydrogen production through biocatalyzed electrolysis was studied for the first time in a single chamber configuration. Single chamber biocatalyzed electrolysis was tested in two configurations: (i) with a cation exchange membrane (CEM) and (ii) with an anion exchange membrane (AEM).

  6. Study of the cross-talk between different gaps of the LHCb Muon chambers

    CERN Document Server

    Martellotti, G; Penso, G; Pinci, D

    2009-01-01

    During the tests before the installation phase of the Multi-Wire Proportional Chambers (MWPC) on the Muon Detector of LHCb an effect of cross talk between the different gas-gaps was found. In this note we present the results of a detailed study of this effect performed on different chambers.

  7. EVALUATION OF RADON EMANATION FROM SOIL WITH VARYING MOISTURE CONTENT IN A SOIL CHAMBER

    Science.gov (United States)

    The paper describes measurements to quantitatively identify the extent to which moisture affects radon emanation and diffusive transport components of a sandy soil radon concentration gradient obtained in the EPA test chamber. The chamber (2X2X4 m long) was constructed to study t...

  8. Exhaust-gas aftertreatment under extreme conditions: validation in a climatic-altitude chamber

    NARCIS (Netherlands)

    Gompel, P. van; Willems, F.P.T.; Doosje, E.; Vergouwe, M.

    2009-01-01

    By testing the vehicle under a wide range of conditions, the new climatic-altitude chamber at TNO will be essential in the various development stages for the integrated systems approach. The CA chamber allows to efficiently deal with the impact of system configuration and system integration on

  9. Study of the bunch crossing identification at LHC using microstrip gas chambers

    Energy Technology Data Exchange (ETDEWEB)

    Angelini, F. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Bacchetta, N. [Istituto Nazionale di Fisica Nucleare, Padua (Italy); Bellazzini, R. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Bon, D. [IPN, Lyon (France); Bondar, A. [Rossijskaya Akademiya Nauk, Novosibirsk (Russian Federation). Inst. Yadernoj Fiziki; Bozzo, M. [Istituto Nazionale di Fisica Nucleare, Genoa (Italy); Brez, A. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Brom, J.M. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Caldero, J.C. [IPN, Lyon (France); Clergeau, J.F. [IPN, Lyon (France); Contardo, D. [IPN, Lyon (France); French, M. [Rutherford Appleton Lab., Chilton (United Kingdom); Giraldo, A. [Istituto Nazionale di Fisica Nucleare, Padua (Italy); Guillot, G. [IPN, Lyon (France); Hall, G. [IC, London (United Kingdom); Hammarstroem, R. [European Organization for Nuclear Research, Geneva (Switzerland); Haroutunian, R. [IPN, Lyon (France); Jones, L. [Rutherford Appleton Lab., Chilton (United Kingdom); Kachelhoffer, T. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Kryn, D. [IPN, Lyon (France); Loreti, M. [Istituto Nazionale di Fisica Nucleare, Padua (Italy); Ladzinski, T. [European Organization for Nuclear Research, Geneva (Switzerland); Mabo, J.C. [IPN, Lyon (France); MacEvoy, B. [IC, London (United Kingdom); Massai, M. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Miguet, M. [IPN, Lyon (France); Millmore, M. [IC, London (United Kingdom); Morelli, A. [Istituto Nazionale di Fisica Nucleare, Genoa (Italy); Nagaslaev, V. [European Organization for Nuclear Research, Geneva (Switzerland); Pallares, A. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Parodi, F. [Istituto Nazionale di Fisica Nucleare, Genoa (Italy); Peisert, A. [European Organization for Nuclear Research, Geneva (Switzerland); Quian, S. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires

    1996-01-01

    During the beam test of a tracker prototype for the Compact Muon Solenoid detector proposed for the LHC, the time response of the Microstrip Gas Chambers was studied using different gases and chamber gaps. The subsequent efficiency to identify the bunch crossings at LHC is discussed for several algorithms used in the off-line signal processing of the data. (orig.).

  10. The CAST Time Projection Chamber

    CERN Document Server

    Autiero, D.; Carmona, J.M.; Cebrian, S.; Chesi, E.; Davenport, M.; Delattre, M.; Di Lella, L.; Formenti, F.; Irastorza, I.G.; Gomez, H.; Hasinoff, M.; Lakic, B.; Luzon, G.; Morales, J.; Musa, L.; Ortiz, A.; Placci, A.; Rodriguez, A.; Ruz, J.; Villar, J.A.; Zioutas, K.

    2007-01-01

    One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data taking periods, and the overall efficiency for the detection of photons coming from conversion of solar axions is 62 %. Shielding has been installed around the detector, lowering the background level to 4.10 x 10^-5 counts/cm^2/s/keV between 1 and 10 keV. During phase I of the CAST experiment the TPC has provided robust and stable operation, thus contributing with a competitive result to the overall CAST limit on axion-photon coupling and mass.

  11. Time Projection Chamber at TRIUMF

    Energy Technology Data Exchange (ETDEWEB)

    Bryman, D.; Leitch, M.; Navon, I.; Numao, T.; Schlatter, P.; Dixit, M.S.; Hargrove, C.K.; Mes, H.; Bennett, A.; Macdonald, J.A.

    1984-01-01

    The Time Projection Chamber at TRIUMF is being used to search for muon-electron conversion. The best spatial resolution in the TPC, sigma approx. = 200 ..mu..m, occurs at the minimum drift length and for an optimum track-to-anode crossing angle determined by the magnetic field. The observed resolution is dependent on the diffusion of the drifting electrons, the track-to-anode crossing angle, vector E X vector B effects near the anode wire and the discrete nature of the ionization process. Distortion due to positive ions leaking back into the drift volume from the anode wire region have been nearly eliminated by the use of a pulsed dual grid system.

  12. Vacuum Chamber for the Booster Bending Magnets

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    To minimize eddy currents, induced by the rising magnetic field, the chamber was made from thin stainless steel of high specific electric resistance. For mechanical stength, it was corrugated in a hydro-forming process. The chamber is curved, to follow the beam's orbital path. Under vacuum, the chamber tends to staighten, the ceramic spacer along half of its length keeps it in place (see also 7402458).

  13. Drift chamber tracking with neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Lindsey, C.S.; Denby, B.; Haggerty, H.

    1992-10-01

    We discuss drift chamber tracking with a commercial log VLSI neural network chip. Voltages proportional to the drift times in a 4-layer drift chamber were presented to the Intel ETANN chip. The network was trained to provide the intercept and slope of straight tracks traversing the chamber. The outputs were recorded and later compared off line to conventional track fits. Two types of network architectures were studied. Applications of neural network tracking to high energy physics detector triggers is discussed.

  14. [Taylor and Hill, Incorporated's JSC Cryo Chamber A

    Science.gov (United States)

    Morales, Rito

    2008-01-01

    NASA commissioned construction of an environmental simulation test chamber which was completed in 1964 at Johnson Space Center (JSC) in Houston, Texas. The facility, Chamber A, was invaluable for testing spacecraft and satellites before deployment to space. By testing spacecraft in an environment similar to the one they would be functioning in, potential problems could be addressed before launch. A new addition to NASA's observatory inventory is called the James Webb Space Telescope (JWST), after a former Administrator of NASA. The new telescope will have 7 times the mirror area of the Hubble, with a target destination approximately one million miles from earth. Scheduled for launch in 2013, the JWST will allow scientists the ability to see, for the first time, the first galaxies that formed in the early Universe. Pre-launch testing of JWST must be performed in environments that approximate its final target space environment as closely as possible.

  15. Computational fluid dynamic (CFD) investigation of thermal uniformity in a thermal cycling based calibration chamber for MEMS

    Science.gov (United States)

    Gui, Xulong; Luo, Xiaobing; Wang, Xiaoping; Liu, Sheng

    2015-12-01

    Micro-electrical-mechanical system (MEMS) has become important for many industries such as automotive, home appliance, portable electronics, especially with the emergence of Internet of Things. Volume testing with temperature compensation has been essential in order to provide MEMS based sensors with repeatability, consistency, reliability, and durability, but low cost. Particularly, in the temperature calibration test, temperature uniformity of thermal cycling based calibration chamber becomes more important for obtaining precision sensors, as each sensor is different before the calibration. When sensor samples are loaded into the chamber, we usually open the door of the chamber, then place fixtures into chamber and mount the samples on the fixtures. These operations may affect temperature uniformity in the chamber. In order to study the influencing factors of sample-loading on the temperature uniformity in the chamber during calibration testing, numerical simulation work was conducted first. Temperature field and flow field were simulated in empty chamber, chamber with open door, chamber with samples, and chamber with fixtures, respectively. By simulation, it was found that opening chamber door, sample size and number of fixture layers all have effects on flow field and temperature field. By experimental validation, it was found that the measured temperature value was consistent with the simulated temperature value.

  16. Bicone vacuum chamber for ISR intersection

    CERN Multimedia

    1975-01-01

    This is one of the bicone chambers made of titanium for experiment R 702. The central corrugated part had a very thin titanium wall (0.28 mm). The first of these chambers collapsed in its central part when baked at 300 C (August 1975). After an intensive effort to develop better quality and reproducible welds for this special material, the ISR workshop was able to build two new chambers of this type. One of them was installed at I 7 for R 702 in 1976 and worked perfectly. It was at that time the most "transparent" intersection vacuum chamber. See also 7609219, 7609221.

  17. Precision Radio Frequency Anechoic Chamber Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Performs measurements and calibration of antennas for satellites and aircraft or groundbased systems. The chamber is primarily used for optimizing antenna...

  18. The Mark II Vertex Drift Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, J.P.; Baggs, R.; Fujino, D.; Hayes, K.; Hoard, C.; Hower, N.; Hutchinson, D.; Jaros, J.A.; Koetke, D.; Kowalski, L.A.

    1989-03-01

    We have completed constructing and begun operating the Mark II Drift Chamber Vertex Detector. The chamber, based on a modified jet cell design, achieves 30 {mu}m spatial resolution and <1000 {mu}m track-pair resolution in pressurized CO{sub 2} gas mixtures. Special emphasis has been placed on controlling systematic errors including the use of novel construction techniques which permit accurate wire placement. Chamber performance has been studied with cosmic ray tracks collected with the chamber located both inside and outside the Mark II. Results on spatial resolution, average pulse shape, and some properties of CO{sub 2} mixtures are presented. 10 refs., 12 figs., 1 tab.

  19. R3B time projection chamber

    Science.gov (United States)

    Legou, P.

    2012-07-01

    Within the international FAIR project, the R3B collaboration (Reaction studies with Radioactive Relativistic beams) will be in charge of the physics program with secondary beams of energy between 200 and 1500MeV per nucleon. Central to the R3B set-up will be a large-aperture superconducting magnet under construction at CEA-Saclay. An international collaboration has been formed to work on the design of a large time-projection chamber (TPC) to be installed behind this magnet to cover the full phase-space of the charged fragments produced in the target. Within this collaboration, tests of detector prototypes were performed with the heavy-ions beams at GSI Darmstadt. These prototypes were equipped with a gaseous Micromegas detector. Two amplification technologies were tested, either conventional or resistive Micromegas and two construction concepts, bulk-Micromegas or micro-meshes screwed on the PCB. We will present the results of the last beam and the 1m TPC station which will be dedicated to make tests using the real drift distance and compare the performances of micromegas and GEM.

  20. Small-sized reverberation chamber for the measurement of sound absorption

    Directory of Open Access Journals (Sweden)

    R. del Rey

    2017-09-01

    Full Text Available This paper presents the design, construction, calibration and automation of a reverberation chamber for small samples. A balance has been sought between reducing sample size, to reduce the manufacturing costs of materials, and finding the appropriate volume of the chamber, to obtain reliable values at high and mid frequencies. The small-sized reverberation chamber, that was built, has a volume of 1.12 m3 and allows for the testing of samples of 0.3 m2. By using diffusers, to improve the diffusion degree, and automating measurements, we were able to improve the reliability of the results, thus reducing test errors. Several comparison studies of the measurements of the small-sized reverberation chamber and the standardised reverberation chamber are shown, and a good degree of adjustment can be seen between them, within the range of valid frequencies. This paper presents a small laboratory for comparing samples and making decisions before the manufacturing of larger sizes.

  1. Contamination Control Assessment of the World's Largest Space Environment Simulation Chamber

    Science.gov (United States)

    Snyder, Aaron; Henry, Michael W.; Grisnik, Stanley P.; Sinclair, Stephen M.

    2012-01-01

    The Space Power Facility s thermal vacuum test chamber is the largest chamber in the world capable of providing an environment for space simulation. To improve performance and meet stringent requirements of a wide customer base, significant modifications were made to the vacuum chamber. These include major changes to the vacuum system and numerous enhancements to the chamber s unique polar crane, with a goal of providing high cleanliness levels. The significance of these changes and modifications are discussed in this paper. In addition, the composition and arrangement of the pumping system and its impact on molecular back-streaming are discussed in detail. Molecular contamination measurements obtained with a TQCM and witness wafers during two recent integrated system tests of the chamber are presented and discussed. Finally, a concluding remarks section is presented.

  2. Endcap Muon Chamber Calibration and Monitoring Procedures in CMS

    CERN Document Server

    Vickey Boeriu, Oana

    2009-01-01

    The cathode strip chamber (CSC) system is one of the three types of muon detectors used in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). It consists of 468 chambers, with a total of $\\sim$218k strips and $\\sim$183k wires, placed onto two endcaps. Calibration tests which monitor the system stability, measure configuration constants that will be downloaded to electronics and calculate the calibration constants needed in the offline reconstruction - like crosstalk, gains, noise and connectivity - are performed regularly. The full chain of acquiring, analyzing and applying the calibration constants was successfully tested recently for the first time on the CSC system, using cosmic-ray data recorded during the Magnet Test and Cosmic Challenge (MTCC).

  3. Wide-band antennas for reverberation chambers

    NARCIS (Netherlands)

    Vogt-Ardatjew, R.A.; van de Beek, G.S.; Leferink, Frank Bernardus Johannes

    2012-01-01

    Shielding effectiveness measurements in a dual vibrating intrinsic reverberation chamber results in very repeatable results for a large frequency range and large dynamic range. Antennas in reverberation chambers do not need any gain, but the losses should be low and the dimensions should be small.

  4. Shielding Effectiveness Measurements using a Reverberation Chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes; Bergsma, J.G.; Bergsma, Hans; van Etten, Wim

    2006-01-01

    Shielding effectiveness measurements have been performed using a reverberation chamber. The reverberation chamber methodology as we1l as the measurement setup is described and some results are given. Samples include glass reinforced plastic panels, aluminum panels with many holes, wire mesh, among

  5. 21 CFR 866.2120 - Anaerobic chamber.

    Science.gov (United States)

    2010-04-01

    ... and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2120 Anaerobic chamber. (a) Identification. An anaerobic chamber is a device intended for medical purposes to maintain an anaerobic (oxygen...

  6. An ionization chamber with magnetic levitated electrodes

    CERN Document Server

    Kawaguchi, T

    1999-01-01

    A new type of ionization chamber which has magnetically levitated electrodes has been developed. The electrodes are supplied voltages for the repelling of ions by a battery which is also levitated with the electrodes. The characteristics of this ionization chamber are investigated in this paper.

  7. Results from the MAC Vertex chamber

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, H.N.

    1987-05-01

    The design, construction, and performance characteristics of a high precision gaseous drift chamber made of thin walled proportional tubes are described. The device achieved an average spatial resolution of 45 ..mu..m in use for physics analysis with the MAC detector. The B-lifetime result obtained with this chamber is discussed.

  8. Validation of a fully anechoic chamber

    NARCIS (Netherlands)

    Mandaris, Dwi; Moonen, Dominicus Johannes Guilielmus; van de Beek, G.S.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2016-01-01

    This paper describes a technique to characterize the performance of a Fully Anechoic Chamber (FAC) from 500 MHz to 3 GHz based on S-Parameter analysis with antennas and a Vector Network Analyzer (VNA. The measurements have been performed by placing one antenna inside the chamber and performing S11

  9. Micro acoustic resonant chambers for heating/agitating/mixing (MARCHAM)

    Science.gov (United States)

    Sherrit, Stewart; Noell, Aaron C.; Fisher, Anita M.; Takano, Nobuyuki; Grunthaner, Frank

    2016-04-01

    tested a variety of chambers. This paper describes the experimental results which are in general agreement with theory within the limitations of the modeling.

  10. Evaluation of linearity of response and angular dependence of an ionization chamber for dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana P.; Neves, Lucio P.; Xavier, Marcos; Caldas, Linda V.E., E-mail: mxavier@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2011-07-01

    In this paper a pencil-type ionization chamber designed and manufactured at Instituto de Pesquisas Energeticas e Nucleares was evaluated for dosimetric applications in computed tomography beams. To evaluate the performance of this chamber two tests were undertaken: linearity of response and angular dependence. The results obtained in these tests showed good results, within the international recommendations. Moreover, this homemade ionization chamber is easy to manufacture, of low cost and efficient. (author)

  11. The HARP Time Projection Chamber

    CERN Document Server

    Vidal-Sitjes, G

    2003-01-01

    A novel apparatus for the calibration of the HARP Time Projection Chamber has been designed, developed and built. The apparatus consists of a large number of point-like photo-electron sources located at precise positions inside the detector volume. The photo-electron sources are optical quartz fibers on which one end is coated with an aluminum layer of $\\sim$80{\\AA} thickness and are held in place on the High Voltage membrane. The fibers are used to guide UV laser light pulses that generate photoelectrons on the fiber tips and these act as photo-electron emitters. The photoelectrons drift inside the detector and produce the calibration signals. The technique allows to asses $E\\times B$ distortions and to measure drift velocity, ion feedback and time stability in real time. The analog signals generated by the TPC front-end electronics have been characterized. Different methods to extract the amplitude and time of occurrence from the digitized signals have been studied and compared. Fast estimators, like the su...

  12. Performance of a parallel plate ionization chamber in beta radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, Patricia L.; Caldas, Linda V.E., E-mail: patrilan@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    A homemade parallel plate ionization chamber with graphite collecting electrode, and developed for use in mammography beams, was tested in relation to its usefulness in beta radiation dosimetry at the Calibration Laboratory of IPEN. Characterization tests of this ionization chamber were performed, using the Sr-90 + Y-90, Kr-85 and Pm-147 sources of a beta secondary standard system. The results of saturation, leakage current, stabilization time, response stability, linearity, angular dependence, and calibration coefficients are within the recommended limits of international recommendations that indicate that this chamber may be used for beta radiation dosimetry. (author)

  13. Monitored Drift Chambers in the ATLAS Detector

    CERN Document Server

    Herten, G

    Monitored Drift Chambers (MDT) are used in the ATLAS Detector to measure the momentum of high energy muons. They consist of drift tubes, which are filled with an Ar-CO2 gas mixture at 3 bar gas pressure. About 1200 drift chambers are required for ATLAS. They are up to 6 m long. Nevertheless the position of every wire needs to be known with a precision of 20 µm within a chamber. In addition, optical alignment sensors are required to measure the relative position of adjacent chambers with a precision of 30µm. This gigantic task seems impossible at first instance. Indeed it took many years of R&D to invent the right tools and methods before the first chamber could be built according to specifications. Today, at the time when 50% of the chambers have been produced, we are confident that the goal for ATLAS can be reached. The mechanical precision of the chambers could be verified with the x-ray tomograph at CERN. This ingenious device, developed for the MDT system, is able to measure the wire position insid...

  14. Manufacture of Cryoshroud Surfaces for Space Simulation Chambers

    Science.gov (United States)

    Ash, Gary S.

    2008-01-01

    Environmental test chambers for space applications use internal shrouds to simulate temperature conditions encountered in space. Shroud temperatures may range from +150 C to -253 C (20 K), and internal surfaces are coated with special high emissivity/absorptivity paints. To obtain temperature uniformity over large areas, detailed thermal design is required for placement of tubing for gaseous or liquid nitrogen and helium and other exotic heat exchange fluids. The recent increase in space simulation activity related to the James Webb Space Telescope has led to the design of new cryogenic shrouds to meet critical needs in instrument package testing. This paper will review the design and manufacturing of shroud surfaces for several of these programs, including fabrication methods and the selection and application of paints for simulation chambers.

  15. Making MUSIC: A multiple sampling ionization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Shumard, B. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)]. E-mail: shumard@phy.anl.gov; Henderson, D.J. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Rehm, K.E. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Tang, X.D. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)

    2007-08-15

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the ({alpha}, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for ({alpha}, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only ({alpha}, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the ({alpha}, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the ({alpha}, p) reaction to reach the anode segment below the reaction.

  16. Investigation of gaseous propellant combustion and associated injector/chamber design guidelines

    Science.gov (United States)

    Calhoon, D. F.; Ito, J. I.; Kors, D. L.

    1973-01-01

    Injector design criteria are provided for gaseous hydrogen-gaseous oxygen propellants. Design equations and procedures are presented which will allow an injector-chamber designer to a priori estimate of the performance, compatibility and stability characteristics of prototype injectors. The effects of chamber length, element geometry, thrust per element, mixture ratio, impingement angle, and element spacing were evaluated for four element concepts and their derivatives. The data from this series of tests were reduced to a single valued mixing function that describes the mixing potential of the various elements. Performance, heat transfer and stability data were generated for various mixture ratios, propellant temperatures, chamber pressures, contraction ratios, and chamber lengths. Applications of the models resulted in the design of procedures, whereby the performance and chamber heat flux can be calculated directly, and the injector stability estimated in conjunction with existing models.

  17. LEP vacuum chamber, cross-section

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Cross-section of the final prototype for the LEP vacuum chamber. The elliptic main-opening is for the beam. The small channel to the left is for the cooling water, to carry away the heat deposited by the synchrotron radiation. The square channel to the right houses the Non-Evaporable Getter (NEG) pump. The chamber is made from extruded aluminium. Its outside is clad with lead, to stop the synchrotron radiation emitted by the beam. For good adherence between Pb and Al, the Al chamber was coated with a thin layer of Ni. Ni being slightly magnetic, some resulting problems had to be overcome. See also 8301153.

  18. Weld Development for Aluminum Fission Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Cross, Carl Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Jesse Norris [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-16

    The Sigma welding team was approached to help fabricate a small fission chamber (roughly ½ inch dia. x ½ inch tall cylinder). These chambers are used as radiation sensors that contain small traces of radionuclides (Cf 252, U 235, and U 238) that serve to ionize gas atoms in addition to external radiation. When a voltage is applied within the chamber, the resulting ion flow can be calibrated and monitored. Aluminum has the advantage of not forming radioactive compounds when exposed to high external radiation (except from minor Na alloy content). Since aluminum has not been used before in this application, this presented an unexplored challenge.

  19. Cloud chamber photographs of the cosmic radiation

    CERN Document Server

    Rochester, George Dixon

    1952-01-01

    Cloud Chamber Photographs of the Cosmic Radiation focuses on cloud chamber and photographic emulsion wherein the tracks of individual subatomic particles of high energy are studied. The publication first offers information on the technical features of operation and electrons and cascade showers. Discussions focus on the relationship in time and space of counter-controlled tracks; techniques of internal control of the cloud chamber; cascade processes with artificially-produced electrons and photons; and nuclear interaction associated with an extensive shower. The manuscript then elaborates on

  20. Radio Frequency Anechoic Chamber Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Supports the design, manufacture, and test of antenna systems. The facility is also used as an electromagnetic compatibility/radio frequency interference...

  1. A scaling method for combustion stability rating of coaxial gas liquid injectors in a subscale chamber

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Chae Hoon; Kim, Young Jun [Sejong Univ., Seoul (Korea, Republic of); Kim, Young Mog [Korea Aerospace Research Institute, Daejeon (Korea, Republic of); Pikalov, Valery P. [Research Institute of Chemical Machine Building, Sergiev Posad (Russian Federation)

    2012-11-15

    A scaling method to examine combustion stability characteristics of a coaxial injector is devised based on the acoustics and combustion dynamics in a chamber. The method is required for a subscale test of stability rating with a model chamber, which is cost effective compared with an actual full scale test. First, scaling and similarity rules are considered for stability rating and thereby, three conditions of acoustic, hydrodynamic, and flame condition similarities are proposed. That is, for acoustic similarity, the natural or resonant frequencies in the actual chamber should be maintained in the model chamber. And, two parameters of density ratio and velocity ratio are derived for the requirement of hydrodynamic and flame condition similarities between the actual and the model conditions. Next, one example of an actual combustion chamber with high performance is selected and the proposed scaling method is applied to the chamber for understanding of the method. The design operating condition for a model test is presented by mass flow rates of propellants. Stability boundaries can be identified on the coordinate plane of chamber pressure and mixture ratio of fuel and oxidizer by applying the scaling method.

  2. Damping insert materials for settling chambers of supersonic wind tunnels

    Science.gov (United States)

    Wu, Jie; Radespiel, Rolf

    2017-03-01

    This study describes the application of a novel damping insert material for reducing the flow fluctuations in a tandem nozzle supersonic wind tunnel. This new damping material is composed of multi-layer stainless steel wired meshes. The influences of the multi-layer mesh, such as the quantity of the mesh layer and the installed location in the settling chamber, to the freestream quality have been investigated. A Pitot probe instrumented with a Kulite pressure sensor and a hot-wire probe are employed to monitor the flow fluctuation in the test section of the wind tunnel. Thereafter, a combined modal analysis is applied for the disturbance qualification. Additionally, the transient Mach number in the test section is measured. The disturbance qualification indicates that the multi-layer mesh performs well in providing reduction of vorticity reduction and acoustic fluctuations. Comparable flow quality of the freestream was also obtained using a combination of flexible damping materials. However, the life-span of the new damping materials is much longer. The time transient of the Mach number measured in the test section indicates that the mean flow is rather constant over run time. Furthermore, the time-averaged pressure along the settling chamber is recorded and it shows the distribution of pressure drop by settling chamber inserts.

  3. LAYOUT AND SIZING OF ESF ALCOVES AND REFUGE CHAMBERS

    Energy Technology Data Exchange (ETDEWEB)

    John Beesley and Romeo S. Jurani

    1995-08-25

    The purpose of this analysis is to establish size requirements and approximate locations of Exploratory Studies Facility (ESF) test and operations alcoves, including refuge chambers during construction of the Topopah Spring (TS) loop. Preliminary conceptual layouts for non-deferred test alcoves will be developed to examine construction feasibility based on current test plans and available equipment. The final location and configuration layout for alcoves will be developed when in-situ rock conditions can be visually determined. This will be after the TBM has excavated beyond the alcove location and the rock has been exposed. The analysis will examine the need for construction of walkways and electrical alcoves in the ramps and main drift. Niches that may be required to accommodate conveyor booster drives and alignments are not included in this analysis. The analysis will develop design criteria for refuge chambers to meet MSHA requirements and will examine the strategic location of refuge chambers based on their potential use in various ESF fire scenarios. This document supersedes DI:BABE00000-01717-0200-00003 Rev 01, ''TS North Ramp Alcove and Stubout Location Analysis'' in its entirety (Reference 5-6).

  4. Reflectivity level of radio anechoic chambers

    DEFF Research Database (Denmark)

    Appel-Hansen, Jørgen

    1973-01-01

    A comparison between the antenna-pattern comparison technique and the free-space voltage standing-wave ratio technique for evaluating the reflectivity level of radio anechoic chambers is presented. Based on an analysis of the two techniques, it is pointed out which parameters influence the measured...... be used to measure the improvements. This work is inspired by the current discussion of finding a figure of merit for anechoic chambers. Based on the results, an evaluation procedure for anechoic chambers is indicated. However, it is pointed out and illustrated by examples that further investigations...... value of the reflectivity level. The comparison is illustrated with experimental results and it is explained why inconsistent and uncorrelated results may be found when the two methods are used. Furthermore, it is demonstrated, by introducing improvements in a chamber, how the reflectivity level can...

  5. RADAR Anechoic Chamber/RCS Measurements Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The RF Anechoic Chamber is 56 feet long by 12 feet high by 13.5 feet wide, with an adjoining electronic computer control room. A double door entrance at one end of...

  6. Developing cloud chambers with high school students

    CERN Document Server

    Ishizuka, Ryo; Sato, Shoma; Zeze, Syoji

    2013-01-01

    The result and outcome of the cloud chamber project, which aims to develop a cloud chamber useful for science education is reported in detail. A project includes both three high school students and a teacher as a part of Super Science High School (SSH) program in our school. We develop a dry ice free cloud chamber using salt and ice (or snow). Technical detail of the chamber is presented. We also argue how the project affects student's cognition, motivation, academic skills and behavior. The research project had been done in very similar way to those of professional researchers, i.e., planning research, applying fund, writing a paper and giving a talk in conferences. From interviews with students, we learn that such style of scientific activity is very effective in promoting student's motivation for learning science.

  7. High Performance Methane Thrust Chamber (HPMTC) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC proposes to develop a High-Performance Methane Thrust Chamber (HPMRE) to meet the demands of advanced chemical propulsion systems for deep-space mission...

  8. Chamber Core Structures for Fairing Acoustic Mitigation

    National Research Council Canada - National Science Library

    Lane, Steven A; Henderson, Kyle; Williams, Andrew; Ardelean, Emil

    2007-01-01

    .... A composite chamber core fairing consists of many axial tubes sandwiched between face sheets, tubes that can be used as acoustic dampers to reduce low-frequency interior noise with virtually no added mass...

  9. Developing Cloud Chambers with High School Students

    Science.gov (United States)

    Ishizuka, Ryo; Tan, Nobuaki; Sato, Shoma; Zeze, Syoji

    The result and outcome of the cloud chamber project, which aims to develop a cloud chamber useful for science education is reported in detail. A project includes both three high school students and a teacher as a part of Super Science High School (SSH) program in our school. We develop a dry-ice-free cloud chamber using salt and ice (or snow). Technical details of the chamber are described. We also argue how the project have affected student's cognition, motivation, academic skills and behavior. The research project has taken steps of professional researchers, i.e., in planning research, applying fund, writing a paper and giving a talk in conferences. From interviews with students, we have learnt that such style of scientific activity is very effective in promoting student's motivation for learning science.

  10. New measurement methods for anechoic chamber characterization

    OpenAIRE

    Gómez Alfageme, Juan José; Sanchez Bote, José Luis; Blanco Martín, Elena

    2008-01-01

    As a continuation of the work presented in 122nd AES Convention, this paper tries to study in depth the anechoic chambers qualification. The purpose of this paper is to find parameters that allow the characterization of this type of enclosures. The proposal that becomes in this work is trying to obtain data of the anechoic chambers absorption by means of the transfer functions between pairs of microphones, or by means of the impulse response between pairs of microphones. Based on the results ...

  11. Signal shapes in a TPC wire chamber

    Science.gov (United States)

    Rossegger, S.; Riegler, W.

    2010-11-01

    We study signal shapes in Multi Wire Proportional Chambers (MWPCs) and the influence of the electron distribution around the wire on the ion tail characteristics. Simulations of the ion tail for two different geometries, different voltages and therefore gas gains were performed. These simulations are compared to measurements carried out with the ALICE TPC wire chambers for a Ne/CO 2/N 2 gas mixture, which allows to extract the avalanche spread around the anode wires of the MWPC.

  12. Georges Charpak and his multiwire chamber

    CERN Multimedia

    1970-01-01

    In 1968, Georges Charpak developed the 'multiwire proportional chamber', a gas-filled box with a large number of parallel detector wires, each connected to individual amplifiers. Linked to a computer, it could achieve a counting rate a thousand times better than existing techniques - without a camera in sight. From left to right, Georges Charpak, Fabio Sauli and Jean-Claude Santiard working on a multiwire chamber in 1970.

  13. The Gargamelle heavy liquid bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1970-01-01

    This image shows the Gargamelle heavy liquid bubble chamber. It was used to detect particles in experiments at the PS between 1970 and 1976 before being moved to the SPS. In 1973, while working on the PS, it detected the first neutral current, an interaction vital to the electroweak theory. In 1978 a large fissure appeared in the body of the chamber and Gargamelle was stopped in 1979.

  14. The world's largest time projection chamber

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Peter Glassel, the technical coordinator for the ALICE time projection chamber, is seen sitting inside the detector; the largest in the world at nearly 100 cubic metres. Thousands of wires are connected to read out electronic data produced as particles are created in lead-lead collisions at the centre of the detector. These particles will cause the medium within the time projection chamber to ionise along their tracks allowing the particle paths to be recreated.

  15. Laser peripheral iridotomy changes anterior chamber architecture.

    Science.gov (United States)

    Theinert, Christian; Wiedemann, Peter; Unterlauft, Jan D

    2017-01-19

    The pressure gradient between anterior and posterior chamber in acute angle closure (AAC) and primary angle closure suspects is balanced by a sufficient laser peripheral iridotomy (LPI). The anterior chamber changes induced by LPI in patients with unilateral AAC were examined and compared to healthy eyes to define threshold values, which may help to discriminate between healthy and diseased eyes. Using Scheimpflug photography, anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), and central corneal thickness (CCT) were measured before and after LPI in both eyes of unilateral AAC cases. These measurements were compared to a group of healthy control eyes to determine threshold values for ACD, ACV, and ACA. The ACD, ACV, and ACA increased significantly in the 25 AAC eyes after LPI. The ACD, ACV, ACA, and CCT values in the AAC eyes obtained before LPI were compared to a control group of 59 healthy eyes with wide open chamber angles. The cutoff values revealed by receiver operating characteristic analysis were 2.1 mm for ACD, 90.5 mm2 for ACV, and 27.25° for ACA. Our results confirm the significant changes of the anterior segments architecture induced by LPI in AAC eyes. The found threshold values for ACD, ACV, and ACA may help in daily clinical routine to discriminate between healthy eyes and those in need for a prophylactic LPI.

  16. Application of Molecular Adsorber Coatings in Chamber A for the James Webb Space Telescope

    Science.gov (United States)

    Abraham, Nithin S.

    2017-01-01

    As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground-based space applications, in particular, for vacuum chamber environments. This presentation describes the application of the MAC technology for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap outgassed contaminants, specifically silicone-based diffusion pump oil, from within JSCs cryogenic optical vacuum chamber test facility called Chamber A. This presentation summarizes the background, fabrication, installation, chemical analysis test results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination. As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground-based space applications, in particular, for vacuum chamber environments. This presentation describes the application of the MAC technology for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap outgassed contaminants, specifically silicone-based diffusion pump oil, from within JSCs cryogenic optical vacuum chamber test

  17. In vitro penetration of bleaching agents into the pulp chamber

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Valera, M C; Mancini, M N G

    2004-01-01

    To investigate pulp chamber penetration of bleaching agents in teeth following restorative procedures.......To investigate pulp chamber penetration of bleaching agents in teeth following restorative procedures....

  18. Reduction of fan noise in an anechoic chamber by reducing chamber wall induced inlet flow disturbances

    Science.gov (United States)

    Dittmar, J. H.; Mackinnon, M. J.; Woodward, R. P.

    1978-01-01

    The difference between the flight and ground static noise of turbofan engines has been identified as a significant problem in engine noise testing. The additional noise for static testing has been attributed to inlet flow disturbances or turbulence interacting with the fan rotor. In an attempt to determine a possible source of inflow disturbances entering fans tested in the Lewis Research Center anechoic chamber the inflow field was studied using potential flow analysis. These potential flow calculations indicated that there was substantial flow over the wall directly behind the fan inlet that could produce significant inflow disturbances. Fan noise tests were run with various extensions added to the fan inlet to move the inlet away from this backwall and thereby reduce the inlet flow disturbances. Significant noise reductions were observed with increased inlet length. Over 5 dB reduction of the blade passage tone sound power level was observed between the shortest and longest inlets at 90% fan speed and the first overtone was reduced 9 dB. High frequency broadband noise was also reduced.

  19. Development of mass-production technique of the ATLAS thin gap chamber in Japan

    CERN Document Server

    Tanaka, S; Ishii, K; Iwasaki, H; Arataki, Y; Bando, T; Homma, Y; Ishino, M; Kondo, T; Kobayashi, T; Kurashige, H; Mikenberg, G; Miyazaki, Y; Nakagawa, Y; Nanjo, H; Ikeno, M; Nozaki, M; Ochi, A; Sasaki, O; Shoa, M; Sugimoto, T; Takeda, H; Takeshita, T; Yokoyama, C

    2004-01-01

    The thin gap chambers (TGCs) are used for the muon trigger system in the end-cap regions of the ATLAS detector. As the anode-cathode distance is small, 1.4 mm, chamber flatness is essential to achieve a uniform gas gain over the chamber. The TGC mass production phase at High Energy Accelerator Research Organization (KEK) started in January 2001. In order to perform a stable production with high quality we developed a chamber closing system. When we glue two half- chambers together, we sandwich them with a granite table and an aluminum honeycomb panel that keep the chamber flat from both sides. By using silk screens, we also control the quantity of epoxy adhesive that affects the chamber thickness. Owing to these developments, we can achieve the flatness of less than 100 mu m. Uniformity of detection efficiency of the TGC is measured with a cosmic-ray test bench at Kobe University. We have tested 300 TGCs so far. Position dependence of the efficiency is measured with a granularity of 5 mm- by-5 mm. The average...

  20. Techniques developed for the ATLAS Thin Gap Chambers mass production in Japan

    CERN Document Server

    Tanaka, S; Ishii, K; Iwasaki, H; Arataki, Y; Bando, T; Homma, Y; Ishino, M; Kondo, T; Kobayashi, T; Kurashige, H; Mikenberg, G; Miyazaki, Y; Nakagawa, Y; Nanjo, H; Ikeno, M; Nozaki, M; Ochi, A; Sasaki, O; Shoa, M; Sugimoto, T; Takeda, H; Takeshita, T; Yokoyama, C

    2004-01-01

    The Thin Gap Chambers (TGCs) are used for the muon trigger system in the end-cap regions of the ATLAS detector. The TGC mass production phase at High Energy Accelerator Research Organization (KEK) started in January 2001. As the anode-cathode distance is small, 1.4 mm, chamber flatness is essential to achieve a uniform gas gain over the chamber. In order to perform a stable production with high quality we developed a chamber closing system. When we glue two half-chambers together, we sandwich them between a granite table and an aluminum honeycomb panel to keep the chamber flat from both sides. By using silk screens, we control the quantity of epoxy adhesive that affects the chamber thickness. Due to these developments, we can achieve the flatness of less than 100 µm. Uniformity of detection efficiency of the TGC is measured with a cosmic-ray test bench at Kobe University. So far we have tested 300 TGCs. Position dependence of the efficiency is measured with a granularity of 5mm-by-5mm. The average efficiency...

  1. Implementation of Autonomous Control Technology for Plant Growth Chambers

    Science.gov (United States)

    Costello, Thomas A.; Sager, John C.; Krumins, Valdis; Wheeler, Raymond M.

    2002-01-01

    The Kennedy Space Center has significant infrastructure for research using controlled environment plant growth chambers. Such research supports development of bioregenerative life support technology for long-term space missions. Most of the existing chambers in Hangar L and Little L will be moved to the new Space Experiment Research and Processing Laboratory (SERPL) in the summer of 2003. The impending move has created an opportunity to update the control system technologies to allow for greater flexibility, less labor for set-up and maintenance, better diagnostics, better reliability and easier data retrieval. Part of these improvements can be realized using hardware which communicates through an ethernet connection to a central computer for supervisory control but can be operated independently of the computer during routine run-time. Both the hardware and software functionality of an envisioned system were tested on a prototype plant growth chamber (CEC-4) in Hangar L. Based upon these tests, recommendations for hardware and software selection and system design for implementation in SERPL are included.

  2. Biomass production chamber air analysis of wheat study (BWT931)

    Science.gov (United States)

    Batten, J. H.; Peterson, B. V.; Berdis, E.; Wheeler, E. M.

    1993-01-01

    NASA's Controlled Ecological Life Support System (CELSS) biomass production chamber at John F. Kennedy Space Center provides a test bed for bioregenerative studies using plants to provide food, oxygen, carbon dioxide removal, and potable water to humans during long term space travel. Growing plants in enclosed environments has brought about concerns regarding the level of volatile organic compounds (VOC's) emitted from plants and the construction materials that make up the plant growth chambers. In such closed systems, the potential exists for some VOC's to reach toxic levels and lead to poor plant growth, plant death, or health problems for human inhabitants. This study characterized the air in an enclosed environment in which wheat cv. Yocora Rojo was grown. Ninty-four whole air samples were analyzed by gas chromatography/mass spectrometry throughout the eighty-four day planting. VOC emissions from plants and materials were characterized and quantified.

  3. Beam Loss Ion Chamber System Upgrade for Experimental Halls

    CERN Document Server

    Dotson, Danny W

    2005-01-01

    The Beam loss Ion Chamber System (BLICS) was developed to protect Jefferson Labs transport lines, targets and beam dumps from a catastrophic "burn through." Range changes and testing was accomplished manually requiring the experiment to be shut down. The new upgraded system is based around an "off the shelf" Programmable Logic Controller located in a single controll box supporting up to ten individual detectors. All functions that formerly required an entry into the experimental hall and manual adjustment can be accomplished from the Machine Control Center (MCC). A further innovation was the addition of a High Voltage "Brick" at the detector location. A single cable supplies the required voltage for the Brick and a return line for the ion chamber signal. The read back screens display range, trip point, and accumulated dose for each location. The new system is very cost effective and significantly reduces the amount of lost experimental time.

  4. A prototype low-background multiwire proportional chamber

    Science.gov (United States)

    Ahmed, Z.; Bowles, M. A.; Bunker, R.; Golwala, S. R.; Grant, D. R.; Kos, M.; Nelson, R. H.; Rider, A.; Schnee, R. W.; Sotolongo, D.; Wang, B.; Zahn, A.

    2014-01-01

    A prototype multiwire proportional chamber (MWPC) was developed to demonstrate the feasibility of constructing a radiopure time projection chamber with MWPC track readout to assay materials for alpha- and beta-emitting surface contaminants for future rare-event-search experiments as well as other scientific fields. The design features and assembly techniques described here are motivated by the position and energy resolution required to reconstruct alpha and beta tracks while efficiently rejecting backgrounds. Results from a test setup using an 55Fe x-ray source indicate excellent operational stability and a near-ideal energy resolution of 15.8% FWHM at 5.89 keV and a gas gain of ~ 104.

  5. Study of the response of low pressure ionization chambers

    CERN Document Server

    Nebot Del Busto, E; Effinger, E; Grishin, V; Herranz Alvarez, J

    2012-01-01

    The Beam Loss Monitoring System (BLM) of the Large Hadron Collider (LHC) is based on parallel plate Ionization Chambers (IC) with active volume 1.5l and a nitrogen filling gas at 0.1 bar overpressure. At the largest loss locations, the ICs generate signals large enough to saturate the read-out electronics. A reduction of the active volume and filling pressure in the ICs would decrease the amount of charge collected in the electrodes, and so provide a higher saturation limit using the same electronics. This makes Little Ionization Chambers (LIC) with both reduced pressure and small active volume a good candidate for these high radiation areas. In this contribution we present measurements performed with several LIC monitors with reduced active volume and various filling pressures. These detectors were tested under various conditions with different beam setups, with standard LHC ICs used for calibration purposes

  6. Measurement and simulation of the drift pulses and resolution in the micro-jet chamber

    Science.gov (United States)

    Va'vra, J.

    1983-11-01

    We have tested a prototype of a micro-jet chamber [1], using both a nitrogen laser and a 10 GeV electron beam. The achieved resolution in the particle beam was σ=18 ≃m for a 1 mm impact parameter and 22 ≃m when averaging over the entire beam profile. The experimental results were compared to a Monte Carlo program which simulates the pulse shapes and resolution in drift chambers of any geometry. The main emphasis in our simulation analysis was to study various timing stategies for drift chambers in order to achieve the best possible timing resolution.

  7. The first precision drift tube chambers for the ATLAS muon spectrometer

    CERN Document Server

    Bauer, F; Dietl, HMunich, Max Planck Inst.; Kotov, S AMunich, Max Planck Inst.; Kroha, HMunich, Max Planck Inst.; Manz, AMunich, Max Planck Inst.; Ostapchuk, A YaMunich, Max Planck Inst.; Richter, RMunich, Max Planck Inst.; Schael, SMunich, Max Planck Inst.; Chouridou, S; Schaile, A D; Staude, A; Ströhmer, R; Trefzger, T M; Diehl, E; Levin, DMichigan U.,; McKee, SMichigan U.,; Neal, HMichigan U.,; Tarle, GMichigan U.,; Thun, RMichigan U.,; Zhou, BMichigan U.,; Bouzakis, K; Krepouri, A; Paschalias, P; Petridou, C; Sampsonidis, D; Tsiafis, I; Valderanis, C; Wotschack, J; Avramidou, R M; Dris, M; Gazis, E N; Katsoufis, E D; Maltezos, S; Stavropoulo, G; Fassouliotis, D; Ioannou, P; Kourkoumelis, C; Birioukov, V; Chelkov, G A; Dedovitch, D V; Evtoukhovitch, P G; Gongadze, A L; Gostkin, M I; Khartchenko, D V; Potrap, I N; Rogalev, E V; Tskhadadze, E G; Zhuravlov, V V

    2002-01-01

    The muon spectrometer of the ATLAS detector for the Large Hadron Collider is designed to provide a muon transverse momentum resolution of 2-10% for momenta between 6 GeV and 1 TeV over a pseudo-rapidity range of |eta |< 2.7. This required the development of precision drift chambers with a track position resolution of 40 micrometer, the Monitored Drift Tube (MDT) chambers. We report about the construction of the three main types of MDT chambers for ATLAS, test results and the first production experience.

  8. The INAF/IAPS Plasma Chamber for ionospheric simulation experiment

    Science.gov (United States)

    Diego, Piero

    2016-04-01

    The plasma chamber is particularly suitable to perform studies for the following applications: - plasma compatibility and functional tests on payloads envisioned to operate in the ionosphere (e.g. sensors onboard satellites, exposed to the external plasma environment); - calibration/testing of plasma diagnostic sensors; - characterization and compatibility tests on components for space applications (e.g. optical elements, harness, satellite paints, photo-voltaic cells, etc.); - experiments on satellite charging in a space plasma environment; - tests on active experiments which use ion, electron or plasma sources (ion thrusters, hollow cathodes, field effect emitters, plasma contactors, etc.); - possible studies relevant to fundamental space plasma physics. The facility consists of a large volume vacuum tank (a cylinder of length 4.5 m and diameter 1.7 m) equipped with a Kaufman type plasma source, operating with Argon gas, capable to generate a plasma beam with parameters (i.e. density and electron temperature) close to the values encountered in the ionosphere at F layer altitudes. The plasma beam (A+ ions and electrons) is accelerated into the chamber at a velocity that reproduces the relative motion between an orbiting satellite and the ionosphere (≈ 8 km/s). This feature, in particular, allows laboratory simulations of the actual compression and depletion phenomena which take place in the ram and wake regions around satellites moving through the ionosphere. The reproduced plasma environment is monitored using Langmuir Probes (LP) and Retarding Potential Analyzers (RPA). These sensors can be automatically moved within the experimental space using a sled mechanism. Such a feature allows the acquisition of the plasma parameters all around the space payload installed into the chamber for testing. The facility is currently in use to test the payloads of CSES satellite (Chinese Seismic Electromagnetic Satellite) devoted to plasma parameters and electric field

  9. Studies on orange oil methyl ester in diesel engine with hemispherical and toroidal combustion chamber

    Directory of Open Access Journals (Sweden)

    Karthickeyan Viswanathan

    2016-01-01

    Full Text Available An investigation has been made to compare the emission characteristics of 20% orange oil methyl ester and 80% diesel in volumetric basis with Neat diesel in hemispherical combustion chamber and toroidal combustion chamber. Non-edible orange oil is selected and utilized to prepare alternative fuel to be utilized in Diesel engine. The traditional method of transestrification is employed for preparation orange oil methyl ester. The chemical properties of prepared methyl ester were determined using fouriertransform infrared spectroscopy method. Further its fuel properties were found based on American Society for Testing and Materials standards and compared with Neat diesel fuel properties. A compression ignition engine with electrical dynamometer test rig with gas analyzer has been used. It is observed that 1% of NOx and 4% of HC emission reduced in toroidal combustion chamber engine. However, smoke emission is found to be lower in hemispherical combustion chamber engine.

  10. Completion of installation of DT and RPC chambers before Cosmic Challenge

    CERN Multimedia

    Mimmo Dattola

    2006-01-01

    All the drift tube ("DT") and resistive plate chambers ("RPC") packages foreseen to be installed in the central barrel ring ("YB0") before the magnet test have been installed (some are missing in the photograph but have since been installed). These silver-coloured rectangular boxes in the gaps between the steel of the rings (red in the image) detect muons. Chambers for Sectors 4 and 5 (sector 1 is at the 9 o'clock position and the counting is clockwise) as well as a couple of chambers in the support "feet" (sectors 9 and 11) will be installed after the magnet test. Chambers for sectors 1 and 7 will be installed in the underground cavern ("UXC") - the latter will be in the places used for the lifting and lowering of the ring.

  11. Mark 1 Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Mark I Test Facility is a state-of-the-art space environment simulation test chamber for full-scale space systems testing. A $1.5M dollar upgrade in fiscal year...

  12. Construction and use of small chambers for boron trifluoride; Construction et utilisation de petites chambres au trifluorure de bore

    Energy Technology Data Exchange (ETDEWEB)

    Caillat, R.; Lallemant, C.; Valladas, G

    1949-07-01

    The fabrication of the chambers (the materials used, the fabrication of the parts and their assembly), and their final testing are described in a first part. Then, the preparation of crude boron fluoride, the storing of the crude, the purification of BF{sub 3} by sublimation and condensation, the pumping, drying and filling up of the chambers, their finishing and sealing are described in a second part. The last part describes the use of the chambers for the counting of slow neutrons: amplification system, pulses discrimination and neutrons counting, accuracy. The characteristics of the amplification circuit used with the chamber are described in the appendix. (J.S.)

  13. Utilization of Double-Water-Chamber Seawall type for Wave Energy Extraction and Wave Dissipation

    OpenAIRE

    Husain, Firman

    2016-01-01

    Variation type and model of wave energy converter have been applied in many countries around the world in order to harvest the ocean wave power. A number of other devices were developing and testing by researchers in the experimental scale. In the present paper investigates double-water-chamber seawall performance for wave energy converter. The main body of water chamber seawall is like OWC structure. Savonius water turbine and guide vanes used to extract a wave power instead of air turbine a...

  14. Experimental and Monte Carlo evaluation of an ionization chamber in a {sup 60}Co beam

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana P.; Neves, Lucio Pereira, E-mail: anapaula.perini@ufu.br [Universidade Federal de Uberlandia (INFIS/UFU), MG (Brazil). Instituto de Fisica; Santos, William S.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Recently a special parallel-plate ionization chamber was developed and characterized at the Instituto de Pesquisas Energeticas e Nucleares. The operational tests presented results within the recommended limits. In order to determine the influence of some components of the ionization chamber on its response, Monte Carlo simulations were carried out. The experimental and simulation results pointed out that the dosimeter evaluated in the present work has favorable properties to be applied to {sup 60}Co dosimetry at calibration laboratories. (author)

  15. Two Italian pupils building an MRPC muon chamber in CERN’s Building 29

    CERN Document Server

    2005-01-01

    For several months, Italian secondary school pupils have been coming to CERN each week and heading for Building 29. They are participating in the EEE (Extreme Energy Events) Project, the aim of which is to carry out a real-life experiment in search of large atmospheric showers using muon detectors located in their schools. In this hall at CERN they are helping to build and test muon chambers - MRPCs (Multigap Resistive Plate Chambers).

  16. Recent experimental results and developments on the resistive plate chambers for the CMS experiment

    CERN Document Server

    Altieri, S; Bruno, G; Guida, R; Merlo, M; Ratti, S P; Riccardi, C; Torre, P; Vitulo, P; Abbrescia, M; Colaleo, A; Iaselli, Giuseppe; Loddo, F; Maggi, M; Marangelli, B; Natali, S; Nuzzo, S; Pugliese, G; Ranieri, A; Romano, F

    2001-01-01

    Resistive plate chambers (RPC) have been chosen as dedicated trigger detectors for the CMS experiment at the LHC. The expected severe operating conditions have required an intense research and development activity on these detectors over the past years. Experimental results on overall performance of large chambers, rate capability, ageing and photon sensitivity are reviewed. In all of these tests the detector has proven to achieve good enough performance for successful use at the LHC. (6 refs).

  17. Repair of isolated double-chambered right ventricle | El Kouache ...

    African Journals Online (AJOL)

    The finding of a double-chambered right ventricle (DCRV) is exceptionally rare as an isolated anomaly. It is a congenital cardiac anomaly in which the right ventricle is separated into two chambers, a proximal highpressure chamber and a distal low-pressure chamber, by anomalous muscles or fibrous tissues in the right ...

  18. Design, analysis, and fabrication of oxide-coated iridium/rhenium combustion chambers

    Science.gov (United States)

    Jang, Q.; Tuffias, R. H.; Laferla, R.; Ghoniem, N. M.

    1993-01-01

    Iridium-coated rhenium (Ir/Re) combustion chambers provide high temperature, oxidation-resistant operation for radiation-cooled liquid-fueled rocket engines. A 22-N (5-lb(sub f)) chamber has been operated for 15 hours at 2200 C (4000 F) using nitrogen tetroxide/monomethyl hydrazine (NTO/MMH) propellant, with negligible internal erosion. The oxidation resistance of these chambers could be further increased by the addition of refractory oxide coatings, providing longer life and/or operation in more oxidizing and higher temperature environments. The oxide coatings would serve as a thermal and diffusion barrier for the iridium coating, lowering the temperature of the iridium layer while also preventing the ingress of oxygen and egress of iridium oxides. This would serve to slow the failure mechanisms of Ir/Re chambers, namely the diffusion of rhenium to the inner surface and the oxidation of iridium. Such protection could extend chamber lifetimes by tens or perhaps hundreds of hours, and allow chamber operation on stoichiometric or higher mixture ratio oxygen/hydrogen (O2/H2) propellant. Extensive thermomechanical, thermochemical, and mass transport modeling was performed as a key material/structure design tool. Based on the results of these analyses, several 22-N oxide-coated Ir/Re chambers were fabricated and delivered to NASA Lewis Research Center for hot-fire testing.

  19. Change of Pressing Chamber Conicalness at Briquetting Process in Briquetting Machine Pressing Chamber

    Directory of Open Access Journals (Sweden)

    Peter Križan

    2012-01-01

    Full Text Available In this paper, we will present the impact of the conical shape of a pressing chamber, an important structural parameter. Besides the known impact of the technological parameters of pressing chambers, it is also very important to pay attention to their structural parameters. In the introduction, we present a theoretical analysis of pressing chamber conicalness. An experiment aimed at detecting this impact was performed at our institute, and it showed that increasing the conicalness of a pressing chamber improves the quality of the final briquettes. The conicalness of the pressing chamber has a significanteffect on the final briquette quality and on the construction of briquetting machines. The experimental findings presented here show the importance of this parameter in the briquetting process.

  20. Determining Temperature Differential to Prevent Hardware Cross-Contamination in a Vacuum Chamber

    Science.gov (United States)

    Hughes, David

    2013-01-01

    When contamination-sensitive hardware must be tested in a thermal vacuum chamber, cross-contamination from other hardware present in the chamber, or residue from previous tests, becomes a concern. Typical mitigation strategies involve maintaining the temperature of the critical item above that of other hardware elements at the end of the test. A formula for relating the pumping speed of a chamber, the surface area of contamination sources, and the temperatures of the chamber, source, and contamination-sensitive items has been developed. The formula allows the determination of a temperature threshold about which contamination will not condense on the sensitive items. It defines a parameter alpha that is the fraction given by (contaminant source area)/[chamber pumping speed (time under vacuum) 0.5]. If this parameter is less than 10(exp -6), cross-contamination from common spacecraft material will not occur when the sensitive hardware is at the same temperature as the source of contamination (The chamber is isothermal within 5 C.). Knowing when it becomes safe to have the hardware isothermal permits faster and easier thermal transitions when compared with maintaining an arbitrary temperature differential between parts. Furthermore, the standard temperature differential may not be adequate under some conditions (alpha>10(exp -4)).

  1. Technical note: Headspace analysis of explosive compounds using a novel sampling chamber.

    Science.gov (United States)

    DeGreeff, Lauryn; Rogers, Duane A; Katilie, Christopher; Johnson, Kevin; Rose-Pehrsson, Susan

    2015-03-01

    The development of instruments and methods for explosive vapor detection is a continually evolving field of interest. A thorough understanding of the characteristic vapor signatures of explosive material is imperative for the development and testing of new and current detectors. In this research a headspace sampling chamber was designed to contain explosive materials for the controlled, reproducible sampling and characterization of vapors associated with these materials. In a detonation test, the chamber was shown to contain an explosion equivalent to three grams of trinitrotoluene (TNT) without damage to the chamber. The efficacy of the chamber in controlled headspace sampling was evaluated in laboratory tests with bulk explosive materials. Small quantities of TNT, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) were separately placed in the sampling chamber, and the headspace of each material was analyzed by gas chromatography/mass spectrometry (GC/MS) with online cryogenic trapping to yield characteristic vapor signatures for each explosive compound. Chamber sampling conditions, temperature and sampling time, were varied to demonstrate suitability for precise headspace analysis. Published by Elsevier Ireland Ltd.

  2. Spin Start Line Effects on the J2X Gas Generator Chamber Acoustics

    Science.gov (United States)

    Kenny, R. Jeremy

    2011-01-01

    The J2X Gas Generator engine design has a spin start line connected near to the turbine inlet vanes. This line provides helium during engine startup to begin turbomachinery operation. The spin start line also acts as an acoustic side branch which alters the chamber's acoustic modes. The side branch effectively creates 'split modes' in the chamber longitudinal modes, in particular below the first longitudinal mode and within the frequency range associated with the injection-coupled response of the Gas Generator. Interaction between the spin start-modified chamber acoustics and the injection-driven response can create a higher system response than without the spin start attached to the chamber. This work reviews the acoustic effects of the spin start line as seen throughout the workhorse gas generator test program. A simple impedance model of the spin start line is reviewed. Tests were run with no initial spin start gas existing in the line, as well as being initially filled with nitrogen gas. Tests were also run with varying spin start line lengths from 0" to 40". Acoustic impedance changes due to different spin start gas constituents and line lengths are shown. Collected thermocouple and static pressure data in the spin start line was used to help estimate the fluid properties along the line length. The side branch impedance model was coupled to a chamber impedance model to show the effects on the overall chamber response. Predictions of the spin start acoustic behavior for helium operation are shown and compared against available data.

  3. Additively Manufactured Low Cost Upper Stage Combustion Chamber

    Science.gov (United States)

    Protz, Christopher; Cooper, Ken; Ellis, David; Fikes, John; Jones, Zachary; Kim, Tony; Medina, Cory; Taminger, Karen; Willingham, Derek

    2016-01-01

    Over the past two years NASA's Low Cost Upper Stage Propulsion (LCUSP) project has developed Additive Manufacturing (AM) technologies and design tools aimed at reducing the costs and manufacturing time of regeneratively cooled rocket engine components. High pressure/high temperature combustion chambers and nozzles must be regeneratively cooled to survive their operating environment, causing their design fabrication to be costly and time consuming due to the number of individual steps and different processes required. Under LCUSP, AM technologies in Sintered Laser Melting (SLM) GRCop-84 and Electron Beam Freeform Fabrication (EBF3) Inconel 625 have been significantly advanced, allowing the team to successfully fabricate a 25k-class regenerative chamber. Estimates of the costs and schedule of future builds indicate cost reductions and significant schedule reductions will be enabled by this technology. Characterization of the microstructural and mechanical properties of the SLM-produced GRCop-84, EBF3 Inconel 625 and the interface layer between the two has been performed and indicates the properties will meet the design requirements. The LCUSP chamber is to be tested with a previously demonstrated SLM injector in order to advance the Technology Readiness Level (TRL) and demonstrate the capability of the application of these processes. NASA is advancing these technologies to reduce cost and schedule for future engine applications and commercial needs.

  4. Commissioning of SLAC SLD 45-Degree Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Eschenburg, Vance O.

    2002-07-19

    The SLD experiment at the Stanford Linear Accelerator Center had a significant gap in its muon tracking coverage, provided by the Warm Iron Calorimeter. Supplemental planes of limited streamer tube chambers were added to improve the coverage in the vicinity of the gap at 0.65 < |cos{theta}| < 0.85. A software effort to upgrade the tracking software for this system is detailed. The commissioning of the forty-five degree chamber region of the SLAC SLD Warm Iron Calorimeter is presented. This task involved the completion of the forty-five degree chamber region geometry for the Warm Iron Calorimeter's fitter and swimmer and the changing of the way multiple scattering effects are treated in the fitter algorithm.

  5. Rapid-Cycling Bubble-Chamber, details

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    Parts of the hydraulic expansion system of the Rapid-Cycling Bubble-Chamber (RCBC). RCBC was the largest of 3 rapid-cycling bubble-chambers (the others were LEBC and HOLEBC), used as target- and vertex-detectors within the European Hybrid Spectrometer (EHS) in the SPS North Area (EHN1). RCBC contained 250 l of liquid hydrogen and was located inside a 3 T superconducting magnet. It was designed for 30 expansions/s (100 times faster than BEBC), the system shown here allowed 50 expansions/s. RCBC operated from 1981 to 1983 for experiments NA21, NA22 and NA23 at a rate of 15 expansions/s, clocking up a total of over 4 million. In the rear, at left, is bearded Lucien Veillet; Augustin Didona is at the right. See also 8001009. The installation of the piston assembly in the RCBC chamber body is shown in the Annual Report 1980, p.65.

  6. High temperature thrust chamber for spacecraft

    Science.gov (United States)

    Chazen, Melvin L. (Inventor); Mueller, Thomas J. (Inventor); Kruse, William D. (Inventor)

    1998-01-01

    A high temperature thrust chamber for spacecraft (20) is provided herein. The high temperature thrust chamber comprises a hollow body member (12) having an outer surface and an internal surface (16) defining the high temperature chamber (10). The body member (12) is made substantially of rhenium. An alloy (18) consisting of iridium and at least alloying metal selected of the group consisting of rhodium, platinum and palladium is deposited on at least a portion of the internal surface (16) of the body member (12). The iridium and the alloying metal are electrodeposited onto the body member (12). A HIP cycle is performed upon the body member (12) to cause the coating of iridium and the alloying metal to form the alloy (18) which protects the body member (12) from oxidation.

  7. Anterior chamber collapse syndrome in a koala.

    Science.gov (United States)

    Liddle, Vl; Naranjo, C; Bernays, Me

    2014-05-01

    Anterior chamber collapse syndrome has been recognised in various species and is associated with early-life ocular disease or trauma. It is important to differentiate this acquired condition from a congenital malformation. An adult female koala (Phascolarctos cinereus) was referred for assessment of buphthalmos and severe keratitis of the right eye. The degree of keratitis obstructed examination of intraocular structures. Enucleation of the affected eye was performed and the histopathological diagnosis was anterior chamber collapse syndrome and secondary glaucoma. This case contributes to the limited information available in the literature on anterior chamber collapse syndrome, a disease unique in having secondary glaucoma with minimal or no inflammation. The case also expands the literature available on ocular disease in koalas. More specifically, this is the only reported case of glaucoma, of any aetiology, in the koala. © 2014 Australian Veterinary Association.

  8. Swirl chamber for vitrification of fly ashes

    Directory of Open Access Journals (Sweden)

    Zarzycki Robert

    2017-01-01

    Full Text Available The study presents the concept of a swirl chamber used for vitrification of fly ashes. It assumes the use of coal dust in the process of fly ash melting. The coal dust supplied to the swirl chamber and gasified in the atmosphere of O2, CO2 and H2O allows for obtaining combustible gases composed of CO and H2, which are burnt with the pneumatically supplied fly ash. The above process allows for obtaining a product in the form of a molten slag which does not contain coal grains. The study presents numerical calculations for the process of combustion and gasification of coal dust and opportunities for ensuring adequate parameters in the fly ash melting zone. The combustible gases obtained during the process of gasification can be supplied to the chamber of a pulverized-bed boiler.

  9. Emulsion chamber experiments for the Space Station

    Science.gov (United States)

    Wilkes, R. J.

    Emulsion chambers offer several unique features for the study of ultrahigh-energy cosmic-ray interactions and spectra aboard a permanent manned Space Station. Emulsion-chamber experiments provide the highest acceptance/weight ratio of any current experimental technique, are invulnerable to mechanical shocks and temperature excursions associated with space flight, do not employ volatile or explosive components or materials, and are not dependent upon data communications or recording systems. Space-Station personnel would be employed to replace track-sensitive materials as required by background accumulation. Several emulsion-chamber designs are proposed, including both conventional passive calorimetric detectors and a hybrid superconducting-magnetic-spectrometer system. Results of preliminary simulation studies are presented. Operational logistics are discussed.

  10. Directional molecular flow analysis and leak detection with a rotatable gas analyzer in a large space simulation chamber

    Science.gov (United States)

    Ehlers, H. K. F.

    1972-01-01

    A system was developed and applied at the NASA Manned Spacecraft Center for measuring and analyzing directional molecular flows in a large thermal vacuum chamber in order to verify molecular environment and identify characteristic and abnormal test article and chamber conditions. The system is described, and some results obtained in over 1200 hours of operation are given.

  11. Development of special ionization chambers for a quality control program in mammography; Desenvolvimento de camaras de ionizacao especiais para controle de qualidade em mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jonas Oliveira da

    2013-07-01

    Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards. (author)

  12. Over the air test

    DEFF Research Database (Denmark)

    2015-01-01

    [1] This invention relates to over-the-air testing of a device in an anechoic chamber. In particular, the invention is suitable for simulating both uplink and downlink over-the-air communication with a device under test even when the anechoic chamber has different numbers of uplink and downlink...

  13. Sealed Plant-Growth Chamber For Clinostat

    Science.gov (United States)

    Brown, Christopher S.; Dreschel, Thomas W.

    1993-01-01

    Laboratory chamber for growing plants used to measure photosynthesis and respiration in simulated microgravity. Holds plant specimens while rotated on clinostat, see article, "Clinostat Delivers Power To Plant-Growth Cabinets" (KSC-11537). Provides way of comparing gas-exchange rates of plants rotated horizontally on clinostat with those of stationary or vertically rotated plants. Gas extracted for analysis without stopping clinostat. Chamber includes potlike base and cylindrical cover, both made of transparent acrylic pipe. Gasket forms seal between cover and bottom plate of base. Cover bolted to pot baseplate, which in turn bolted to clinostat.

  14. A view inside the Gargamelle bubble chamber

    CERN Multimedia

    1970-01-01

    Gargamelle was the name given to a big bubble chamber built at the Saclay Laboratory in France during the late 1960s. It was designed principally for the detection at CERN of the elusive particles called neutrinos. A bubble chamber contains a liquid under pressure, which reveals the tracks of electrically charged particles as trails of tiny bubbles when the pressure is reduced. Neutrinos have no charge, and so leave no tracks, but the aim with Gargamelle was "see neutrinos" by making visible any charged particles set in motion by the interaction of neutrinos in the liquid

  15. The Rufous Hornero (Furnarius rufus) nest as an incubation chamber.

    Science.gov (United States)

    Shibuya, Felipe L S; Braga, Talita V; Roper, James J

    2015-01-01

    Foraging and incubation are mutually exclusive activities for parent birds. A trade-off is generated when a combination of food availability and temperature regulation force birds to choose one and neglect the other, at least temporarily. The Rufous Hornero builds large, oven-like, mud nests, the evolutionary cause of which remains unknown. We tested that temperature variation inside the nest is that which is expected if one function of the nest were for temperate regulation. If so, this would suggest that the nest works as an incubation chamber (but which now may serve more than one function). We divided nests into two natural treatments: nests that received more continuous direct sunshine (sun), and those that received less direct sunshine, due to shade from trees or buildings (shade). Thermometer data loggers were placed in the nest cavity and outside, in the shade of the nest, and temperature was measured every 10min. We predicted that temperatures would consistently be higher and less variable in nests than outside nests. Also, at higher ambient temperatures the nest would function better as an incubation chamber as a consequence of having evolved in a hotter climate. Thus, in Curitiba, where temperatures are lower than where the species (and nest) evolved, nests in greater sunshine should have thermal characteristics that support the incubation chamber hypothesis. Predictions were supported: with Repeated Measures ANOVA and t-tests, we found that temperatures were more constant and higher in nests, especially when in the sun, and as the season progressed (hotter ambient temperatures). We conclude that the large mud nest of the Rufous Hornero works as an incubation chamber that likely evolved to help resolve the incubation-foraging trade-off in the very seasonal and hot regions where the bird evolved. Thus, as an incubation chamber, the nest allows the bird to forage rather than incubate thereby resolving the foraging-incubation trade-off and potentially

  16. Proportional chambers of the barrel hadron calorimeter of the L3 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Arefiev, A.; Azemoon, T.; Bachmann, U.; Ball, R.C.; Boehlen, W.E.; Capell, M.; Chen, C.; Chen, H.S.; Chumakov, M.; Galaktionov, Yu.

    1989-02-01

    The design and the mass production of the proportional wire chambers for the barrel part of the uranium-gas sampling hadron calorimeter of the L3 detector at the CERN Large Electron-Positron storage ring (LEP) are described. The chambers meet the specific requirements arising from the limited space available to the calorimeter, the radioactivity of uranium, and the physics criteria of good energy and position resolution for incident hadrons. The mass production techniques employed ensured that all of the 371664 chamber cells have uniform response (with 5% accuracy) to ionizing particles. Over 8000 chambers of the same design, in 53 different sizes, were manufactured and tested at the ITEP (Moscow), at the University of Michigan (Ann Arbor) and at the IHEP (Beijing).

  17. A compact multi-chamber setup for degradation and lifetime studies of organic solar cells

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Jørgensen, Mikkel; Krebs, Frederik C

    2011-01-01

    A controlled atmosphere setup designed for long-term degradation studies of organic solar cells under illumination is presented. The setup was designed with ease-of-use and compactness in mind and allows for multiple solar cells distributed on four glass substrates to be studied in four different...... chambers with temperature and atmosphere control. The four chambers are situated at close proximity in the setup thereby allowing the solar cells to be subjected to as uniform an illumination distribution as possible for the given solar simulator employed. The cell substrates serve as the front window...... and present a tight seal. Hence no illumination correction needs to be performed due to transmission and reflection losses as otherwise seen with test chambers employing a window as a seal. The solar cells in each chamber are continuously and individually electrically monitored under biased conditions...

  18. Evaluation of the uniformity of concentration of radon in a radon chamber.

    Science.gov (United States)

    Xiongjie, Zhang; Ye, Zhang; Yang, Liu; Bin, Tang

    2016-04-01

    In order to solve the problem that the evaluation results of the uniformity of concentration of radon in a radon chamber via various methods were difficult to compare, according to its statistical properties, a mathematical model was built to analyze the uniformity of concentration of radon; an evaluation method for the overall uniformity of concentration of radon was proposed on the basis of single-factor multi-group ANOVA, and a detection method for nonuniform points in a radon chamber was proposed on the basis of single-factor two-group t-test; an evaluation process of the uniformity of concentration of radon in a radon chamber was established. The proposed method was applied to evaluate the HD-6 small and medium-sized radon chambers and achieved good results. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Validation of an Animal Isolation Imaging Chamber for Use in Animal Biosafety Level-3 Containment.

    Science.gov (United States)

    Alderman, T Scott; Frothingham, Richard; Sempowski, Gregory D

    2010-01-01

    Live imaging of animals infected with pathogenic microbes poses a contamination risk to equipment, personnel and other animals. A Caliper animal isolation chamber designed for the IVIS(®) Spectrum imaging system was tested as a containment device for mice infected with microbes assigned to animal biosafety level-3 (ABSL-3). A testing protocol was developed by adapting two published standards to test other equipment in high containment environments. The protocol included quantitative leak-testing of the high efficiency particulate air (HEPA) filters, soap bubble testing of the animal isolation chamber, and pressure decay testing of the complete containment system. HEPA filters were > 99.999% efficient (soap bubble testing at flow rates of 0.25 L/min to 2.0 L/min, generating pressures up to 2.90 in H(2)O. (26-fold increase over normal operating pressure). The complete containment system passed pressure decay testing at 2.0 in H(2)O by sustaining 95% of the initial pressure over a 30 minute period.The Caliper animal isolation chamber provides appropriate isolation for the IVIS(®) Spectrum imaging system. When used as a containment device, it must undergo periodic performance testing, as described here, since it operates under positive pressure. The chamber is an appropriate component of ABSL-3 containment when combined with proper administrative controls and work practices. The testing protocol described here can be used to validate containment devices for other imaging systems or animal species.

  20. Effects of inlet distortion on gas turbine combustion chamber exit temperature profiles

    Science.gov (United States)

    Maqsood, Omar Shahzada

    Damage to a nozzle guide vane or blade, caused by non-uniform temperature distributions at the combustion chamber exit, is deleterious to turbine performance and can lead to expensive and time consuming overhaul and repair. A test rig was designed and constructed for the Allison 250-C20B combustion chamber to investigate the effects of inlet air distortion on the combustion chamber's exit temperature fields. The rig made use of the engine's diffuser tubes, combustion case, combustion liner, and first stage nozzle guide vane shield. Rig operating conditions simulated engine cruise conditions, matching the quasi-non-dimensional Mach number, equivalence ratio and Sauter mean diameter. The combustion chamber was tested with an even distribution of inlet air and a 4% difference in airflow at either side. An even distribution of inlet air to the combustion chamber did not create a uniform temperature profile and varying the inlet distribution of air exacerbated the profile's non-uniformity. The design of the combustion liner promoted the formation of an oval-shaped toroidal vortex inside the chamber, creating localized hot and cool sections separated by 90° that appeared in the exhaust. Uneven inlet air distributions skewed the oval vortex, increasing the temperature of the hot section nearest the side with the most mass flow rate and decreasing the temperature of the hot section on the opposite side. Keywords: Allison 250, Combustion, Dual-Entry, Exit Temperature Profile, Gas Turbine, Pattern Factor, Reverse Flow.

  1. Drift Chambers detectors; Detectores de deriva

    Energy Technology Data Exchange (ETDEWEB)

    Duran, I.; Martinez laso, L.

    1989-07-01

    We present here a review of High Energy Physics detectors based on drift chambers. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysed, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author) 115 refs.

  2. Vacuum chamber for intersection I-4

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Vacuum chamber for intersection I-4 of the ISR being assembled inside a wooden mock-up of the gap of the split-field magnet. The central round-cylinder section is provisional and is to be replaced by an elliptic-cylinder section to give more space vertically for installation of detectors. Supports for the central section are of carbon fibre composite.

  3. Spark chambers in the Microcosm museum

    CERN Multimedia

    Patrice Loiez

    1990-01-01

    These spark chambers were displayed in CERN's permanent exhibition, Microcosm. These were particle detectors in which the tracks of particles would be seen by sparks created along the particle's path. While touring Microcosm, visitors can learn more about this and other detector methods both past and present.

  4. Intracapsular cataract extraction with anterior chamber intraocular ...

    African Journals Online (AJOL)

    Aim: To assess the visual outcome of cataract extraction with ACIOL implantation in a Nigerian hospital. Methods: The visual outcome of 50 eyes of 42 patients aged 40 years and above, out of 212 eyes that underwent intracapsular cataract extraction (ICCE) and anterior chamber intraocular lens (ACIOL) implantation, were ...

  5. IKAR, a ionization chamber for WA9

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    This ionization chamber arrived at CERN from Leningrad for a high precision study of hadron elastic scattering by a CERN-Clermont-Ferrand-Leningrad-Lyon-Uppsala Collaboration in the H3 beam (WA9). G.A. Korolev (third from right) looks at the drawings.

  6. Presenting Chamber Music to Young Children

    Science.gov (United States)

    Smith, Terry Fonda

    2011-01-01

    The number of professional ensembles and organizations with dedicated outreach concerts has been steadily increasing over the past decade. More recently, educational concerts pairing chamber music with young children have been documented. The work presented in this article is a study in the efficacy and feasibility of this format. Various music…

  7. The arrival of the CLOUD chamber

    CERN Multimedia

    CERN AVC

    2009-01-01

    The team from the CLOUD experiment - the world’s first experiment using a high-energy particle accelerator to study the climate - were on cloud nine after the arrival of their new three-metre diameter cloud chamber. This marks the end of three years’ R&D; and design, and the start of preparations for data taking later this year.

  8. Prototype vacuum chamber for ISR intersection region

    CERN Multimedia

    1974-01-01

    The vacuum chambers at the ISR interaction regions had to be as transparent as possible to the secondary particles emerging from the collision points. Made from stainless steel or titanium, only a fraction of a millimeter thick, they were most delicate to handle.

  9. Prototype Vacuum Chamber for ISR Intersection Region

    CERN Multimedia

    1974-01-01

    The vacuum chambers at the ISR interaction region had to be as transparent as possible to the secondary particles emerging from the collision points. Made from stainless steel or titanium, only a fraction of a millimeter thick, they were most delicate to handle.

  10. The use of microholography in bubble chambers

    CERN Document Server

    Royer, H

    1981-01-01

    In-line holography has been used for the first time in a bubble chamber for the account of the CERN (Geneva, CH). The holograms were recorded with the help of a single-mode pulse laser. Bubble tracks of 25 microns in diameter have been reconstructed with a resolution of 2 microns. (12 refs).

  11. Highly efficient resistive plate chambers for high rate environment

    CERN Document Server

    Cwiok, M; Górski, M; Królikowski, J

    1999-01-01

    The full scale prototype of an inverted double gap RPC module for ME-1/1 station of the CMS detector was tested in the gamma irradiation facility at the CERN SPS muon beam. The chamber made of medium resistivity bakelite and filled with "green gas" mixture of C /sub 2/H/sub 2/F/sub 4//iso-butane/SF/sub 6/ has wide efficiency plateau and good timing properties when operated in avalanche mode under continuous irradiation with strong /sup 137/Cs source for rates up to about 5 kHz/cm/sup 2//gap. (10 refs).

  12. Two-dimensional microgap gas chambers on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Marel, J. van der [Delft Univ. of Technol. (Netherlands). Fac. of Appl. Phys.]|[Delft Univ. of Technol. (Netherlands). Inst. of Microelectron. and Submicrotechnol.; Bogaard, A. van der [Delft Univ. of Technol. (Netherlands). Fac. of Appl. Phys.]|[Delft Univ. of Technol. (Netherlands). Inst. of Microelectron. and Submicrotechnol.; Eijk, C.W.E. van [Delft Univ. of Technol. (Netherlands). Fac. of Appl. Phys.]|[Delft Univ. of Technol. (Netherlands). Inst. of Microelectron. and Submicrotechnol.; Hollander, R.W. [Delft Univ. of Technol. (Netherlands). Fac. of Appl. Phys.]|[Delft Univ. of Technol. (Netherlands). Inst. of Microelectron. and Submicrotechnol.; Sarro, P.M. [Delft Univ. of Technol. (Netherlands). Fac. of Appl. Phys.]|[Delft Univ. of Technol. (Netherlands). Inst. of Microelectron. and Submicrotechnol.

    1995-12-11

    We are manufacturing microgap chambers (MGC) on silicon with two-dimensional read-out. They have an anode pitch of 100 {mu}m and a cathode pitch of 400 {mu}m. We obtained a maximum gas gain of 2500 and the avalanche charge collection takes place within 15 ns. The stability of the gas gain is very good. We have tested the position resolution for the detection of X-rays. It appears that the gas composition and the strength of the drift field are important parameters. A high concentration of dimethylether and a rather small drift field provide the smallst size of the total avalanche. (orig.).

  13. Performances of keystone geometry micro-strip gas chambers

    CERN Document Server

    Chiari, M; Tonetto, F; Travaglini, L

    2002-01-01

    The performances of micro-strip gas chamber detectors with CF sub 4 counting gas have been tested with a sup 2 sup 4 sup 1 Am alpha source. The behaviour of the gain as a function of gas pressure, the dependence of the energy resolution on gas pressure and anode voltage, and the gain variation along the strip length due to the keystone geometry of the micro-strip pads are reported. An empirical response function to describe such a position dependence of the gain is proposed.

  14. Carbon wire chamber at sub-atmospheric pressure

    Science.gov (United States)

    Charles, G.; Audouin, L.; Bettane, J.; Dupre, R.; Genolini, B.; Hammoudi, N.; Imre, M.; Le Ven, V.; Maroni, A.; Mathon, B.; Nguyen Trung, T.; Rauly, E.

    2017-05-01

    Present in many experiments, wire and drift chambers have been used in a large variety of shapes and configurations during the last decades. Nevertheless, their readout elements has not evolved much: tungsten, sometimes gold-plated or aluminum, wires. By taking advantage of the developments in the manufacture of conducting carbon fiber, we could obtain interesting improvements for wire detectors. In this article, we present recent tests and simulations using carbon fibers to readout signal in place of traditional tungsten wires. Unlike metallic wires, their low weight guaranties a reduced quantity of material in the active area.

  15. Steel Primer Chamber Assemblies for Dual Initiated Pyrovalves

    Science.gov (United States)

    Guemsey, Carl S.; Mizukami, Masashi; Zenz, Zac; Pender, Adam A.

    2009-01-01

    A solution was developed to mitigate the potential risk of ignition failures and burn-through in aluminum primer chamber assemblies on pyrovalves. This was accomplished by changing the assembly material from aluminum to steel, and reconfiguration of flame channels to provide more direct paths from initiators to boosters. With the geometric configuration of the channels changed, energy is more efficiently transferred from the initiators to the boosters. With the alloy change to steel, the initiator flame channels do not erode upon firing, eliminating the possibility of burn-through. Flight qualification tests have been successfully passed.

  16. Distant teaching of chamber music via local area networks

    DEFF Research Database (Denmark)

    Bitzer, Joerg; May, Tobias; Kurtisi, Zefir

    2006-01-01

    In this paper we present a study on teaching chamber music via internet. The application for this setup is for a highly reputed teacher to teach professional musicians at a very high level. Usually, all participants would have to fly from all over the world in order to work together. Therefore......, it would be of great value, if these teaching lessons could be done via internet. Several audio and video devices and different audio setups have been tested. The results indicate that MPEG 2 broadcast devices with two microphones are suitable for this task....

  17. Anterior chamber fixation of a posterior chamber intraocular lens: A novel technique

    Directory of Open Access Journals (Sweden)

    A Sahap Kükner

    2014-01-01

    Full Text Available We aimed to evaluate the implantation of a posterior chamber intraocular lens (IOL in the anterior chamber (AC with the haptics passing through two iridectomies to the posterior chamber. A total of 33 eyes of 33 patients with inadequate posterior capsular support due to either previous aphakia or posterior capsular rupture during cataract extraction were included in the study. A double iridectomy was performed on all patients using a vitrectomy probe on the midperiphery of the iris. IOLs were implanted in the AC, and the haptics were passed through the iridectomies to the posterior chamber. The mean follow-up time was 25.3 months. AC hemorrhage occurred in five patients during the iridectomy procedure. Corneal edema was detected in eight of 14 patients with primary IOL insertions. Haptic dislocation was detected in only one patient. This technique may be a good alternative to scleral-fixated IOL implantation in eyes with aphakia.

  18. Altitude Chamber Testing of the Passenger Oxygen System (POS)

    Science.gov (United States)

    2009-08-01

    centrally located under the sternum (breast bone ), a dry progressive cough, and difficulty with inspiration. There may be a sense of suffocation and...bag. A maxillary sinus block may cause referred pain to the upper teeth, and thus be mistaken for barodontalgia (pain in the teeth produced by

  19. Metallic spherical anechoic chamber for antenna pattern measurement

    Science.gov (United States)

    Farahbakhsh, Ali; Khalaj-Amirhosseini, Mohammad

    2016-08-01

    Anechoic chambers are used for indoor antenna measurements. The common method of constructing an anechoic chamber is to cover all inside walls by the electromagnetic absorbers. In this paper, a fully metallic spherical chamber structure is presented in which the propagation of the electromagnetic waves inside the chamber is controlled and they are guided to an absorber. In the proposed method, an appropriate quiet zone is obtained, and unlike ordinary anechoic chambers, the absorber usage amount is reduced greatly. The performance of the chamber is evaluated by simulation. The results show that the proposed method could provide a useful technique for the indoor antenna measurements.

  20. Electronic Combat Integrated Test Facilities

    National Research Council Canada - National Science Library

    1992-01-01

    ... and evaluating weapons systems hardware and software in a controlled ground test environment. These facilities consist of anechoic chambers connected to various simulation and instrumentation laboratories...

  1. An uncommon variant of double-chambered right ventricle masquerading as double-chambered left ventricle.

    Science.gov (United States)

    Baritakis, Nikolaos; Grapsas, Nikolaos; Kotsalos, Andreas; Davlouros, Periklis

    2018-02-01

    We present a rare case of a double-chambered right ventricle masquerading as a double-chambered left ventricle, which was found incidentally on cardiac imaging in an adult female patient with atypical chest pain. The most common form of double-chambered right ventricle is characterized by compartmentalization of the right ventricle by muscular bands into 2 distinct chambers. The main features of this malformation are a pressure gradient between the 2 compartments, and the frequent (up to 90%) association with a membranous ventricular septal defect. In our case, the muscular band dividing the right ventricle was located in the inferoseptal part of the latter, creating a diminutive cavity that had no communication with the main right ventricle but communicated with the left ventricle creating the false impression of a double-chambered left ventricle. This constitutes a rare variant of double-chambered right ventricle with unknown clinical implications. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  3. Technical Note: Semi-rigid chambers for methane gas flux measurements on tree-stems

    Science.gov (United States)

    Siegenthaler, A.; Welch, B.; Pangala, S. R.; Peacock, M.; Gauci, V.

    2015-09-01

    There is increasing interest in the measurement of methane (CH4) emissions from tree stems in a wide range of ecosystems so as to determine how they contribute to the total ecosystem flux. To date, tree CH4 fluxes are commonly measured using rigid closed chambers (static or dynamic), which often pose challenges as these are bulky and limit measurement of CH4 fluxes to only a very narrow range of tree stem sizes and shapes. To overcome these challenges we aimed to design, describe and test new semi-rigid stem-flux chambers (or sleeves). We compared semi-rigid chamber's gas permeability to CH4 against the traditional rigid chamber approach, in the laboratory and in the field, with continuous flow or syringe injections. We found that the semi-rigid chambers performed well, and had numerous benefits including reduced gas permeability and optimal stem gas exchange surface to total chamber volume ratio (Sc/Vtot) allowing better headspace mixing, especially when connected in a dynamic mode to a continuous flow gas analyser. Semi-rigid sleeves can easily be constructed and transported in multiple sizes, are extremely light, cheap to build and fast to deploy. This makes them ideal for use in remote ecosystems where access logistics are complicated.

  4. Study of the BIS-MDT /ATLAS Chambers with Cosmic Rays

    CERN Document Server

    Tsarouchas, Charilaos; Gazis, Evangelos; Tsipolitis, Georgios

    This thesis is a study of data obtained from cosmic tests of BIS chambers. BIS chambers belong to the muon sub detector of ATLAS experiment at the CERN laboratory in Geneva. Moreover BIS chambers are Greek implemented chambers from a fruitful collaboration of University of Athens (construction of tubes), Na- tional Technical University of Athens (quality assurance and quality Control) and University of Thesaloniki (final assembly). From September of 2000 to the April of 2004 the Greek muon team tried its best to implement the 112 BIS-MDT chambers. The study if this thesis, is a small ring in this chain of completion steps and connects previous work and installation procedures programmed for April of 2006. Briefly, this thesis gives in the first chapter information about the CERN lab- oratory, the ATLAS experiment and the BIS-MDT chambers. In chapter 2, pre- sented some very elementary operation principles of BIS detection unit, the MDT tube. In chapter 3, an extensive study of TDC spectrum is done and in para...

  5. Evaluation of the Effects of Menstrual Cycle on Anterior Chamber Parameters as Measured with Pentacam

    Directory of Open Access Journals (Sweden)

    Arzu Seyhan Karatepe

    2013-01-01

    Full Text Available Pur po se: To evaluate the effects of endogenous gonadotropic hormones (follicle-stimulating hormone, luteinizing hormone and sex steroids (progesterone, estrogen to anterior segment parameters. Ma te ri al and Met hod: Thirty healthy females who had a menstrual cycle of 28±1 day and with a mean age of 36.5±7.56 (range, 20 – 46 years were included in the study. Starting from the first day of their cycle, Pentacam Scheimpflug camera measurements were performed on the 1st, 3rd, 7th, 12th, 16th, 21st, 26th, and 28th days. The central corneal thickness, anterior chamber depth, anterior segment volume, keratometric values, anterior chamber angle value, and pupilla diameter of both eyes were evaluated. Repeated measures analysis of variance test was used for statistical analysis. Re sults: No difference that reaches statistical significance was found in the means of central corneal thickness, anterior chamber volume, keratometric values, anterior chamber angle, and pupilla diameter between the days. Mean anterior chamber depth measurement of the right eyes on the 1st day was 2.72±0.44 mm, whereas it was 2.77±0.46 mm on the 26th day. Mean anterior chamber depth measurement of the left eyes on the 1st day was 2.74±0.42 mm, whereas it was 2.80±0.43 mm on the 26th day. This increment of anterior chamber depth value from the 1st to the 26th days was found to be statistically significant (p≤0.05. Dis cus si on: Progesterone and estrogen that rise in the second half of the menstrual cycle might have a deepening effect on the anterior chamber. These findings should be further investigated with more profound studies that also evaluate the hormonal values and their correlations with anterior segment parameters. (Turk J Ophthalmol 2013; 43: 15-8

  6. The Effect of Heat Treatments and Coatings on the Outgassing Rate of Stainless Steel Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Mamum, Md Abdullah A. [Old Dominion Univ., Norfolk, VA (United States); Elmustafa, Abdelmageed A, [Old Dominion Univ., Norfolk, VA (United States); Stutzman, Marcy L. [JLAB, Newport News, VA (United States); Adderley, Philip A. [JLAB, Newport News, VA (United States); Poelker, Matthew [JLAB, Newport News, VA (United States)

    2014-03-01

    The outgassing rates of four nominally identical 304L stainless steel vacuum chambers were measured to determine the effect of chamber coatings and heat treatments. One chamber was coated with titanium nitride (TiN) and one with amorphous silicon (a-Si) immediately following fabrication. One chamber remained uncoated throughout, and the last chamber was first tested without any coating, and then coated with a-Si following a series of heat treatments. The outgassing rate of each chamber was measured at room temperatures between 15 and 30 deg C following bakes at temperatures between 90 and 400 deg C. Measurements for bare steel showed a significant reduction in the outgassing rate by more than a factor of 20 after a 400 deg C heat treatment (3.5 x 10{sup 12} TorrL s{sup -1}cm{sup -2} prior to heat treatment, reduced to 1.7 x 10{ sup -13} TorrL s{sup -1}cm{sup -2} following heat treatment). The chambers that were coated with a-Si showed minimal change in outgassing rates with heat treatment, though an outgassing rate reduced by heat treatments prior to a-Si coating was successfully preserved throughout a series of bakes. The TiN coated chamber exhibited remarkably low outgassing rates, up to four orders of magnitude lower than the uncoated stainless steel. An evaluation of coating composition suggests the presence of elemental titanium which could provide pumping and lead to an artificially low outgassing rate. The outgassing results are discussed in terms of diffusion-limited versus recombination-limited processes.

  7. The physics of Resistive Plate Chambers

    CERN Document Server

    Riegler, Werner

    2004-01-01

    Over the last 3 years we investigated theoretical aspects of Resistive Plate Chambers (RPC) in order to clarify some of the outstanding questions on space charge effects, high efficiency of small gap RPCs, charge spectra, signal shape and time resolution. In a series of reports we analyzed RPC performance including all detector aspects covering primary ionization, avalanche multiplication, space charge effects, signal induction in presence of resistive materials, crosstalk along detectors with long strips and front-end electronics. Using detector gas parameters entirely based on theoretical predictions and physical models for avalanche development and space charge effects we are able to reproduce measurements for 2 and 0.3 mm RPCs to very high accuracy without any additional assumptions. This fact gives a profound insight into the workings of RPCs and also underlines the striking difference in operation regime when compared to wire chambers. A summary of this work as well as recent results on three-dimensiona...

  8. Introduction for Diffusion Chamber Culture Symposium

    Energy Technology Data Exchange (ETDEWEB)

    Carsten, A. L.

    1979-01-01

    The diffusion-chamber system has been applied to studies of cell kinetics, progenitor cell quantitation, humoral effects, immunological effects, cytogenetics, organogenesis, and the cellular effects of drugs and physical factors such as radiation, hypoxia, etc. Chamber contents have been analyzed by clot dissolution with measuring of cell content, limiting dilution evaluation, radionuclide utilization (tritiated thymidine labeling), growth of colony number, size and type, CFU-S or CFU-C content, or proliferation by secondary culture in mice or in vitro systems, and chromosome changes. Cell types ranging from embryonal tissues to adult normal and neoplastic tissues have been grown in hosts across species barriers. Advantages and disadvantages of this system are discussed.

  9. The KLOE drift chamber VCI 2001

    CERN Document Server

    Adinolfi, M; Ambrosino, F; Andryakov, A; Antonelli, A; Antonelli, M; Anulli, F; Bacci, C; Bankamp, A; Barbiellini, G; Bellini, F; Bencivenni, G; Bertolucci, Sergio; Bini, C; Bloise, C; Bocci, V; Bossi, F; Branchini, P; Bulychjov, S A; Cabibbo, G; Calcaterra, A; Caloi, R; Campana, P; Capon, G; Carboni, G; Cardini, A; Casarsa, M; Cataldi, G; Ceradini, F; Cervell, F; Cevenini, F; Chiefari, G; Ciambrone, P; Conetti, S; Conticelli, S; De Lucia, E; De Robertis, G; De Simone, P; De Zorzi, G; De Sangro, R; Dell'Agnello, S; Denig, A; Di Domenico, A; Di Donato, C; Di Falco, S; Doria, A; Drago, E; Elia, V; Erriquez, O; Farilla, A; Felici, G; Ferrari, A; Ferrer, M L; Finocchiaro, G; Forti, C; Franceschi, A; Franzini, P; Gao, M L; Gatti, C; Gauzzi, P; Giovannella, S; Golovatyuk, V; Gorini, E; Grancagnolo, F; Grandegger, W; Graziani, E; Guarnaccia, P; Han, H G; Han, S W; Huang, X; Incagli, M; Ingrosso, L; Jang, Y Y; Kim, W; Kluge, W; Kulikov, V; Lacava, F; Lanfranchi, G; Lee-Franzini, J; Lomtadze, F; Luisi, C; Mao Chen Sheng; Martemyanov, M; Matsyuk, M; Mei, W; Merola, L; Messi, R; Miscetti, S; Moalem, A; Moccia, S; Moulson, M; Murtas, F; Müller, S; Napolitano, M; Nedosekin, A; Pacciani, L; Pagès, P; Palutan, M; Panareo, M; Paoluzi, L; Pasqualucci, E; Passalacqua, L; Passaseo, M; Passeri, A; Patera, V; Petrolo, E; Petrucci, Guido; Picca, D; Pirozzi, G; Pistillo, C; Pollack, M; Pontecorvo, L; Primavera, M; Ruggieri, F; Santangelo, P; Santovetti, E; Saracino, G; Schamberger, R D; Schwick, C; Sciascia, B; Sciubba, A; Scuri, F; Sfiligoi, I; Shan, J; Silano, P; Spadaro, T; Spagnolo, S; Spiriti, E; Stanescu, C; Tong, G L; Tortora, L; Valente, E; Valente, P; Valeriani, B; Venanzoni, G; Veneziano, Stefano; Von Hagel, U; Wu, Y; Xie, Y G; Zhao, P P; Zhou, Y

    2002-01-01

    The main goal of the KLOE experiment at the Frascati DAPHINE phi-factory is the study CP violation in kaon decays. The tracking device of the experiment is a drift chamber whose dimensions, 4 m of diameter and 3.3 m length, provide a large acceptance volume for the decay products of low momentum K sub L (lambda sub L =3.4 m). A complete stereo geometry with 12.582 cells arranged in 58 layers guarantees a high and uniform efficiency in the reconstruction of the charged K sub L decays. Very light materials have been chosen both for the drift medium, a helium-based gas mixture, and for the mechanical structure, made of carbon fiber, to minimize multiple scattering and conversion of low-energy photons. The design requirements, the adopted solutions together with the calibration procedure and the tracking performances of the drift chamber are discussed.

  10. Diurnal variations in a sealed radon chamber

    Science.gov (United States)

    Gilboy, W. B.; James, P. R.; Farmer, C. P.; Beard, J. E.

    1990-12-01

    During experiments to calibrate a radon-in-air counter, some unexpected diurnal variations have been observed. Inside the sealed stainless-steel chamber of a nominal volume of 3 litres, ionised 218Po atoms from the alpha-decay of 222Rn are attracted by an electric field to a ZnS(Ag) scintillation screen via which subsequent α-decay events are detected. Results for this configuration are presented and also for a modified version in which the scintillation screen is replaced by a high-resolution α-detector. Ambient temperature changes were suspected to be responsible for the observed counting-efficiency variation and this has been confirmed by operating the wall of the chamber at various temperatures between 0°C and about 40°C, which revealed a positive temperature coefficient of ˜1%/°C at 25°C. Possible reasons for this effect are considered.

  11. Dataset of Building and Environment Publication in 2016, A reference method for measuring emissions of SVOCs in small chambers

    Data.gov (United States)

    U.S. Environmental Protection Agency — The data presented in this data file is a product of a journal publication. The dataset contains DEHP air concentrations in the emission test chamber. This dataset...

  12. Wire chambers with their magnetostrictive readout

    CERN Multimedia

    1974-01-01

    This set of wire chamber planes shaped as a cylinder sector was installed inside the magnet of a polarized spin target modified to allow as well momentum analysis of the produced particles. The experiment (S126) was set up by the CERN-Trieste Collaboration in the PS beam m9 to measure spin effects in the associated production of of a positive kaon and a positive Sigma by interaction of a positive pion with polarized protons.

  13. The Bern Infinitesimal Bubble Chamber (BIBC)

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    The chamber body was machined from a block of aluminium. The visible volume was cylindrical with 65 mm diameter and 35 mm depth. It was filled with propane or freon. It was meant as vertex detector in the search of short-lived particles. It was also used with in-line holography resulting in 8 µm bubble size and 9 cm depth of the field. See E. Ramseyer, B. Hahn and E. Hugentobler, Nucl. Instrum. Methods 201 (1982) 335.

  14. Efficient Determination of Reverberation Chamber Time Constant

    OpenAIRE

    Zhang, Xiaotian; Robinson, Martin P.; Flintoft, Ian D.; Dawson, John F.

    2017-01-01

    Determination of the rate of energy loss in a reverberation chamber is fundamental to many different measurements such as absorption cross-section, antenna efficiency, radiated power, and shielding effectiveness. Determination of the energy decay time-constant in the time domain by linear fitting the power delay profile, rather than using the frequency domain quality-factor, has the advantage of being independent of the radiation efficiency of antennas used in the measurement. However, determ...

  15. Vacuum Chamber for the Booster Bending Magnets

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    To minimise eddy currents, induced by the rising magnetic field, the chamber was made from thin stainless steel of high specific electric resistance. For mechanical strength, it was corrugated in a hydro-forming process. The cross-section was designed for maximum strength and maximum aperture. To accept particles with simultaneous large amplitudes in both planes, the cross-section approaches a rectangular shape (see also 7402463).

  16. Cell seeding chamber for bone graft substitutes

    OpenAIRE

    Hennig, J.; Schieker, Matthias; Seitz, H.

    2012-01-01

    There is an increasing demand for bone graft substitutes that are used as osteoconductive scaffolds in the treatment of bone defects and fractures. Achieving optimal bone regeneration requires initial cell seeding of the scaffolds prior to implantation. The cell seeding chamber is a closed assembly. It works like a sandglass. The position of the scaffold is between two reservoirs containing the fluid (e. g. blood). The fluid at the upper reservoir flows through the scaffold driven by gravity....

  17. VPS Process for Copper Components in Thrust Chamber Assemblies

    Science.gov (United States)

    Elam, Sandra; Holmes, Richard; Hickman, Robert; McKechnie, Tim; Thom, George

    2005-01-01

    For several years, NASA's Marshall Space Flight Center (MSFC) has been working with Plasma Processes, Inc., (PPI) to fabricate thrust chamber liners with GRCop-84. Using the vacuum plasma spray (VPS) process, chamber liners of a variety of shapes and sizes have been created. Each has been formed as a functional gradient material (FGM) that creates a unique protective layer of NiCrAlY on the GRCop-84 liner s hot wall surface. Hot-fire testing was successfully conducted on a subscale unit to demonstrate the liner's durability and performance. Similar VPS technology has also been applied to create functional gradient coatings (FGC) on copper injector faceplates. Protective layers of NiCrAlY and zirconia were applied to both coaxial and impinging faceplate designs. Hot-fire testing is planned for these coated injectors in April 2005. The resulting material systems for both copper alloy components allows them to operate at higher temperatures with improved durability and operating margins.

  18. Modifications of a Composite-Material Combustion Chamber

    Science.gov (United States)

    Williams, Brian E.; McNeal, Shawn R.

    2005-01-01

    Two short reports discuss modifications of a small, lightweight combustion chamber that comprises a carbon/carbon composite outer shell and an iridium/ rhenium inner liner. The first report discusses chamber design modifications made as results of hot-fire tests and post-test characterization. The Books & Reports 32 NASA Tech Briefs, June 2005 modifications were intended to serve a variety of purposes, including improving fabrication, reducing thermal-expansion mismatch stresses, increasing strength-to-weight ratios of some components, and improving cooling of some components. The second report discusses (1) the origin of stress in the mismatch between the thermal expansions of the Ir/Re liner and a niobium sleeve and flange attached to the carbon/ carbon shell and (2) a modification intended to relieve the stress. The modification involves the redesign of an inlet connection to incorporate a compressible seal between the Ir/Re liner and the Nb flange. A nickel alloy was selected as the seal material on the basis of its thermal-expansion properties and its ability to withstand the anticipated stresses, including the greatest stresses caused by the high temperatures to be used in brazing during fabrication.

  19. Diurnal Variation of Anterior Chamber Flare

    Directory of Open Access Journals (Sweden)

    Mehmet Adam

    2015-04-01

    Full Text Available Objectives: To investigate the ideal time and reproducibility of anterior chamber flare measurements. Materials and Methods: Anterior chamber flare measurements were performed with laser flaremetre device at 8 am to 45 volunteers and these measurements were repeated on the same day at 12 pm and 4 pm. Results: Twenty-five (55.5% of the volunteers were women and 20 (44.5% were men; mean age was 28.67±7.40 (18-49 years. The mean anterior chamber flare measurements taken following the ophthalmologic examination were 5.94±1.41 foton/msn at 8 am, 5.65±1.45 foton/msn at 12 pm, and 5.79±1.20 foton/msn at 4 pm. No statistical difference was found between the measurements (p=0.08. Subgroup analysis according to eye color, revealed no significant difference between flare measurements in brown, hazel, and green eyes (p=0.21. Correlation analysis demonstrated association between age and all flare measurements within the day (r=0.24, p=0.03; r=0.41, p=0.01, r=0.27, p=0.01. Conclusion: No significant diurnal change was detected in the flare measurements of our study subjects but positive correlation with age was observed. Hence, all flare measurements within a day are reliable and have high repeatability in healthy subjects. (Turk J Ophthalmol 2015; 45: 52-5

  20. Close cathode chamber: Low material budget MWPC

    Science.gov (United States)

    Varga, Dezső; Kiss, Gábor; Hamar, Gergő; Bencédi, Gyula

    2013-01-01

    Performance of asymmetric-type MWPC-s are presented. In this structure, referred to as Close Cathode Chamber in an earlier study, the material budget is significantly reduced on one hand by the elimination of external support frame, on the other hand by thin detector walls. In this paper it is demonstrated that the outline is compatible with large size detectors (1 m wire length), maintaining mechanical and operation stability, with total weight of 3 kg (including support structure) for a half square meter surface. The detection efficiency and response time is shown to be sufficient for L0 triggering in the ALICE VHMPID layout. Reduced sensitivity to cathode deformations (due to internal overpressure as mechanical strain) is directly demonstrated. On small sized chambers, improvement of position resolution with analog readout is evaluated, reaching 0.09 mm RMS with 2 mm wide cathode segments. Simulation results on signal time evolutions are presented. With the above studies, comparison of classical MWPC-s and the Close Cathode Chamber design is performed in all major aspects.

  1. Menstrual history in altitude chamber trainees.

    Science.gov (United States)

    Schirmer, J U; Workman, W T

    1992-07-01

    Previous studies have determined a higher rate of altitude-induced decompression sickness (DCS) in women than in men. Women are reportedly at higher risk for developing DCS during menses. A study of menstrual history in women completing altitude chamber training without developing DCS has never been accomplished. The purpose of this study was to collect and analyze menstrual history in these women. Thirteen U.S. Air Force Aerospace Physiology Units participated in a USAF-approved survey for 1 year. After completing altitude chamber flights, data on age, day of menstrual cycle (DMC), birth control pill use (BCP), and mean durations of menstrual cycle and menses were collected. There were 508 responses analyzed. There was no differences between mean duration of menstrual cycle and menses in the Yes (Y) and No (N) BCP groups. Y and N BCP groups were equally distributed across the menstrual cycle. Women completing altitude chamber training without developing DCS appear to be evenly distributed across their menstrual cycle, with use of BCPs not affecting their susceptibility to DCS.

  2. RF Anechoic Chambers, Tri-Service Research Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — In collaboration with the Navy, there are 12 RF Anechoic and static free exposure chambers located at TSRL. These chambers cover the majority of the RF spectrum and...

  3. Performance of three pencil-type ionization chambers (10 cm) in computed tomography standard beams

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E., E-mail: mcastro@ipen.br, E-mail: mxavier@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The use of computed tomography (CT) has increased over the years, thus generating a concern about the doses received by patients undergoing this procedure. Therefore, it is necessary to perform routinely beam dosimetry with the use of a pencil-type ionization chamber. This detector is the most utilized in the procedures of quality control tests on this kind of equipment. The objective of this work was to perform some characterization tests in standard CT beams, as the saturation curve, polarity effect, ion collection efficiency and linearity of response, using three ionization chambers, one commercial and two developed at the IPEN. (author)

  4. Response and Monte Carlo evaluation of a reference ionization chamber for radioprotection level at calibration laboratories

    Science.gov (United States)

    Neves, Lucio P.; Vivolo, Vitor; Perini, Ana P.; Caldas, Linda V. E.

    2015-07-01

    A special parallel plate ionization chamber, inserted in a slab phantom for the personal dose equivalent Hp(10) determination, was developed and characterized in this work. This ionization chamber has collecting electrodes and window made of graphite, and the walls and phantom made of PMMA. The tests comprise experimental evaluation following international standards and Monte Carlo simulations, employing the PENELOPE code to evaluate the design of this new dosimeter. The experimental tests were conducted employing the radioprotection level quality N-60 established at the IPEN, and all results were within the recommended standards.

  5. Effect of sintering columns on the heat transfer and flow characteristics of the liquid cooling vapor chambers

    Science.gov (United States)

    Naphon, Paisarn; Wiriyasart, Songkran

    2016-09-01

    The results of the heat and flow characteristics of working fluid inside the vapor chamber with different sintering columns of 20, 81, 225 are presented. The vapor chambers with one inlet port and four outlet ports are tested by using water as coolant. Parametric studies including different heat fluxes, number and size of wick columns, and flow rate of coolants on the cooling performance are considered. A three-dimensional heat and mass transfer model for vapor chamber with wick and without sintering plate and sintering columns are developed. The numerical simulation results show the velocity and pressure distribution of liquid and vapor phases of the working fluid inside the vapor chamber. It is found that the number of wick column have an important influence to the velocity and pressure phenomena of working fluid which results in thermal performance of vapor chamber. Reasonable agreement is obtained from the comparison between the measured data and the predicted results.

  6. Effect of bleaching agents on bonding to pulp chamber dentine.

    Science.gov (United States)

    Timpawat, S; Nipattamanon, C; Kijsamanmith, K; Messer, H H

    2005-04-01

    To determine the effect of intracoronal bleaching agents on adhesion of bonding agents to pulp chamber dentine. Forty extracted human maxillary anterior teeth were randomly divided into four groups of 10 teeth each. Bleaching agents were sealed in pulp chambers for 7 days, as in clinical use. Group 1 (control): distilled water, group 2: 35% hydrogen peroxide, group 3: sodium perborate mixed with water, and group 4: sodium perborate mixed with 35% hydrogen peroxide. Teeth were stored in saline at 37 degrees C for 7 days. After the bleaching agent was removed, teeth were leached in water for a further 7 days prior to bonding. The crown was cut vertically from mesial to distal and the labial pulp chamber dentine was prepared for bonding with Clearfil SE-Bond and filled with resin composite (Clearfil AP-X). The bonded specimens were kept moist at 37 degrees C for 24 h. Microtensile bond strengths were determined using a universal testing machine. Additional teeth were prepared using the same bleaching procedures to investigate the scanning electron microscopic appearance of the dentine surface. Mean values (+/-SD) of microtensile bond strength for the experimental groups were: group 1: 5.29 +/- 2.21 MPa, group 2: 5.99 +/- 1.51 MPa, group 3: 9.17 +/- 1.65 MPa and group 4: 3.99 +/- 1.31 MPa. Dentine treated with sodium perborate in water (group 3) had significantly higher mean bond strength when compared with the other three groups (P sodium perborate plus hydrogen peroxide (group 4). In terms of subsequent bond strength during restoration, sodium perborate mixed with distilled water appears to be the best intracoronal bleaching agent.

  7. Anechoic chamber in industrial plants. [construction materials and structural design

    Science.gov (United States)

    Halpert, E.; Juncu, O.; Lorian, R.; Marfievici, D.; Mararu, I.

    1974-01-01

    A light anechoic chamber for routine acoustical measurements in the machine building industry is reported. The outer housing of the chamber consists of modules cast in glass fiber reinforced polyester resin; the inner housing consists of pyramidal modules cut out of sound absorbing slates. The parameters of this anechoic chamber facilitate acoustical measurements according to ISO and CAEM recommendations.

  8. A cylindrical drift chamber with azimuthal and axial position readout

    Energy Technology Data Exchange (ETDEWEB)

    Bar-Yam, Z.; Cummings, J.P.; Dowd, J.P.; Eugenio, P.; Hayek, M.; Kern, W.; King, E.; Shenhav, N.; Chung, S.U.; Hackenburg, R.W.; Olchanski, C.; Weygand, D.P.; Willutzki, H.J.; Brabson, B.B.; Crittenden, R.R.; Dzierba, A.R.; Gunter, J.; Lindenbusch, R.; Rust, D.R.; Scott, E.; Smith, P.T.; Sulanke, T.; Teige, S.; Denisov, S.; Dushkin, A.; Kochetkov, V.; Lipaev, V.; Popov, A.; Shein, I.; Soldatov, A.; Anoshina, E.V.; Bodyagin, V.A.; Demianov, A.I.; Gribushin, A.M.; Kodolova, O.L.; Korotkikh, V.L.; Kostin, M.A.; Ostrovidov, A.I.; Sarycheva, L.I.; Sinev, N.B.; Vardanyan, I.N.; Yershov, A.A.; Adams, T.; Bishop, J.M.; Cason, N.M.; Sanjari, A.H.; LoSecco, J.M.; Manak, J.J.; Shephard, W.D.; Stienike, D.L.; Taegar, S.A.; Thompson, D.R.; Brown, D.S.; Pedlar, T.; Seth, K.K.; Wise, J.; Zhao, D.; Adams, G.S.; Napolitano, J.; Nozar, M.; Smith, J.A.; Witkowski, M. [Massachusetts Univ., North Dartmouth, MA (United States)]|[Brookhaven National Laboratory, Upton, L.I., NY 11973 (United States)]|[Indiana University, Bloomington, IN 47405 (United States)]|[Institute for High Energy Physics, Protvino (Russian Federation)]|[Institute of Nuclear Physics, Moscow State University, Moscow (Russian Federation)]|[University of Notre Dame, Notre Dame, IN 46556 (United States)]|[Northwestern University, Evanston, IL 60208 (United States)]|[Rensselaer Polytechnic Institute, Troy, NY 12180 (United States)

    1997-02-21

    A cylindrical multiwire drift chamber with axial charge-division has been constructed and used in experiment E852 at Brookhaven National Laboratory. It serves as a trigger element and as a tracking device for recoil protons in {pi}{sup -}p interactions. We describe the chamber`s design considerations, details of its construction, electronics, and performance characteristics. (orig.).

  9. 7 CFR 58.423 - Cheese vacuumizing chamber.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cheese vacuumizing chamber. 58.423 Section 58.423 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....423 Cheese vacuumizing chamber. The vacuum chamber shall be satisfactorily constructed and maintained...

  10. Bi-cone vacuum chamber in the ISR

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The "bi-cone" vacuum chamber in ISR intersection I-7, for experiment R702. Made from 0.28 mm thick titanium, it was at its time the most transparent chamber ever built. Ian Wilson is standing next to the chamber. See also 7609219.

  11. Installation and Commissioning of the new GLM Implantation Chamber

    CERN Document Server

    Pohl, Christoph

    2016-01-01

    Summer student report about the work with the new implantation chamber for the GLM branch of ISOLDE. In the context of this project an API for the vacuum system of the new chamber was developed and implemented in web application that will be used to control the new implantation chamber at some point.

  12. 30 CFR 56.7807 - Flushing the combustion chamber.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...

  13. 30 CFR 57.7807 - Flushing the combustion chamber.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...

  14. Engineering analyses of large precision cathode strip chambers for GEM

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, J.A.; Belser, F.C.; Pratuch, S.M.; Wuest, C.R. [Lawrence Livermore National Lab., CA (United States); Mitselmakher, G. [Superconducting Super Collider Lab., Dallas, TX (United States); Gordeev, A. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Johnson, C.V. [Lawrence Livermore National Lab., CA (United States)]|[Superconducting Super Collider Lab., Dallas, TX (United States); Polychronakos, V.A. [Brookhaven National Lab., Upton, NY (United States); Golutvin, I.A. [Joint Institute for Nuclear Research, Dubna (Russian Federation)

    1993-10-21

    Structural analyses of large precision cathode strip chambers performed up to the date of this publication are documented. Mechanical property data for typical chamber materials are included. This information, originally intended to be an appendix to the {open_quotes}CSC Structural Design Bible,{close_quotes} is presented as a guide for future designers of large chambers.

  15. Evaluation of a plane-parallel ionization chamber for low-energy radiotherapy beams

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana Paula; Neves, Lucio Pereira; Santos, William de Souza; Caldas, Linda V.E., E-mail: aperini@ipen.br, E-mail: lpneves@ipen.br, E-mail: wssantos@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    A plane-parallel ionization chamber, with a sensitive volume of 6.3 cm{sup 3}, developed at the Calibration Laboratory of IPEN (LCI), was utilized to verify the possibility of its application in low-energy X-ray beam qualities for radiotherapy (T-qualities). This homemade ion chamber was manufactured using polymethyl methacrylate (PMMA) coated with graphite, and co-axial cables. In order to evaluate the performance of this ionization chamber, some characterization tests were performed: short- and medium-term stability, leakage current, saturation, ion collection efficiency, polarity effect and linearity of response. The maximum value obtained in the short-term stability test was 0.2%, in accordance with the limit value of 0.3% provided by the IEC 60731 standard. The saturation curve was obtained varying the applied voltage from -400 V to +400 V, in steps of 50 V, using the charge collecting time of 20 s. From the saturation curve two other characteristics were analyzed: the polarity effect and the ion collection efficiency, with results within the international recommendations. The leakage current of the ionization chamber was measured in time intervals of 20 minutes, before and after its irradiations, and all the results obtained were in agreement with the IEC 60731 standard. The linearity of response was verified utilizing the T-50(b) radiation quality, and the ionization chamber was exposed to different air kerma rates. The response of the ionization chamber presented a linear behavior. Therefore, all results were considered satisfactory, within international recommendations, indicating that this homemade ionization chamber presents potential routine use in dosimetry of low-energy radiotherapy beams. (author)

  16. Ozone deposition to an oat crop ( Avena sativa L.) grown in open-top chambers and in the ambient air

    Science.gov (United States)

    Pleijel, H.; Wallin, G.; Karlsson, P. E.; Skarby, L.; Sellden, G.

    Fluxes and deposition velocities for ozone were determined for open-top chambers with and without an oat crop, and for the adjacent field, using a resistance analogue model and the aerodynamic wind-profile method, respectively. During a period when the canopy was green and the ambient wind speeds modest, the fluxes and deposition velocities were higher in the chamber with plants than in the field crop. The deposition to chamber walls and soil in the chamber only accounted for part of that difference. The deposition velocity for ozone to the crop was light-dependent both in the chamber with plants and in the ambient air. With increasing plant senescence, the deposition velocity declined and the light dependence disappeared. Fluctuations in deposition velocity superimposed on the overall declining trend followed the same temporal pattern in the chambers with and without plants. These fluctuations in deposition velocity may partly be explained by variations in surface wetness. Differences in boundary layer conductance between chamber and ambient, which under certain conditions may significantly influence the validity of the chamber as a test system, were observed.

  17. Safety observation of applying anterior chamber gas injection for unstable anterior chamber at the end of cataract surgery

    National Research Council Canada - National Science Library

    Yong-Zhi Huang; Tao Sun; Yu-Ting Zhi; Li Li; Lu-Ning Yan

    2015-01-01

    AIM: To observe the surgical effect, complications and assess the safety of applying anterior chamber injection of sterile air to treat instability of anterior chamber occurred at the end of cataract...

  18. Status on the Verification of Combustion Stability for the J-2X Engine Thrust Chamber Assembly

    Science.gov (United States)

    Casiano, Matthew; Hinerman, Tim; Kenny, R. Jeremy; Hulka, Jim; Barnett, Greg; Dodd, Fred; Martin, Tom

    2013-01-01

    Development is underway of the J -2X engine, a liquid oxygen/liquid hydrogen rocket engine for use on the Space Launch System. The Engine E10001 began hot fire testing in June 2011 and testing will continue with subsequent engines. The J -2X engine main combustion chamber contains both acoustic cavities and baffles. These stability aids are intended to dampen the acoustics in the main combustion chamber. Verification of the engine thrust chamber stability is determined primarily by examining experimental data using a dynamic stability rating technique; however, additional requirements were included to guard against any spontaneous instability or rough combustion. Startup and shutdown chug oscillations are also characterized for this engine. This paper details the stability requirements and verification including low and high frequency dynamics, a discussion on sensor selection and sensor port dynamics, and the process developed to assess combustion stability. A status on the stability results is also provided and discussed.

  19. A combination drift chamber/pad chamber for very high readout rates

    Energy Technology Data Exchange (ETDEWEB)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W. [Fermi National Accelerator Lab., Batavia, IL (United States); Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J. [Wisconsin Univ., Madison, WI (United States); Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P. [Pavia Univ. (Italy)]|[Istituto Nazionale di Fisica Nucleare, Rome (Italy); Arenton, M.; Conetti, S.; Cox, B.; Dukes, E.; Golovatyuk, V.; Hanlet, P.; McManus, A.; Nelson, K.; Recagni, M.; Segal, J.; Sun, J. [Virginia Univ., Charlottesville, VA (United States); Ballagh, C.; Bingham, H.; Kaeding, T.; Lys, J.; Misawa, S. [California Univ., Berkeley, CA (United States); Blankman, A.; Borodin, S.; Kononenko, W.; Newcomer, M.; Selove, W.; Trojak, T.; VanBerg, R.; Zhang, S.N. [Pennsylvania Univ., Philadelphia, PA (United States); Block, M.; Corti, G.; LeCompte, T.; Rosen, J.; Yao, T. [Northwestern Univ., Evanston, IL (United States); Boden, A.; Cline, D.; Ramachandran, S.; Rhoades, J.; Tokar, S. [California Univ., Los Angeles, CA (United States); Budagov, J.; Tsyganov, E. [Joint Inst. for Nuclear Research, Dubna (USSR); Cao, Z.L.; He, M.; Wang, C.; Wei, C.; Zhang, N. [Shandong Univ., Jinan, SD (China); Chen, T.Y.; Yao, N. [Nanjing Univ., JS (China); Clark, K.; Jenkins, M. [University of South Alabama, Mobile, AL (United States); Cooper, M. [Vanier Inst. of the Family, Ottawa, ON (Canada); Creti, P.; Gorini, E.; Grancagnolo, F.; Panareo, M. [Lecce Univ. (Italy)]|[Istituto Nazionale di Fisica Nucleare, Rome (Italy); Fortney, L.; Kowald, W. [Duke Univ., Durham, NC (United States); Haire, M.; Judd, D.; Turnbull, L.; Wagoner, D. [Texas A and M Univ., Prairie View, TX (United States); Lau, K.; Mo, G. [Houston Univ., TX (United States); Trischuk, J. [McGill Univ., Montreal, PQ (Canada)

    1991-11-01

    Six medium-sized ({approx}1 {times} 2 m{sup 2}) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers.

  20. A novel non invasive measurement of hemodynamic parameters: Comparison of single-chamber ventricular and dual-chamber pacemaker

    Directory of Open Access Journals (Sweden)

    Ingrid M. Pardede

    2008-03-01

    Full Text Available We carried out a cross sectional study to analyze hemodynamic parameters of single-chamber ventricular pacemaker compared with dual-chamber pacemaker by using thoracic electrical bioimpedance monitoring method (Physio Flow™ - a novel simple non-invasive measurement. A total of 48 consecutive outpatients comprised of 27 single chamber pacemaker and 21 dual chamber were analyzed. We measured cardiac parameters: heart rate, stroke volume index, cardiac output index, estimated ejection fraction, end diastolic volume, early diastolic function ratio, thoracic fluid index, and systemic parameters: left cardiac work index and systemic vascular resistance index. Baseline characteristic and pacemaker indication were similar in both groups. Cardiac parameters assessment revealed no significant difference between single-chamber pacemaker and dual-chamber pacemaker in heart rate, stroke volume index, cardiac index, estimated ejection fraction, end-diastolic volume, thoracic fluid index. There was significantly higher early diastolic function ratio in single-chamber pacemaker compared to dual-chamber pacemaker: 92% (10.2-187.7% vs. 100.6% (48.7-403.2%; p=0.006. Systemic parameters assessment revealed significantly higher left cardiac work index in single-chamber group than dual-chamber group 4.9 kg.m/m² (2.8-7.6 kg.m/m² vs. 4.3 kg.m/m² (2.9-7.2 kg.m/m²; p=0.004. There was no significant difference on systemic vascular resistance in single-chamber compared to dual-chamber pacemaker. Single-chamber ventricular pacemaker provides similar stroke volume, cardiac output and left cardiac work, compared to dual-chamber pacemaker. A non-invasive hemodynamic measurement using thoracic electrical bioimpedance is feasible for permanent pacemaker outpatients. (Med J Indones 2008; 17: 25-32Keywords: Permanent pacemaker, single chamber, dual chamber, thoracic electrical bioimpedance, hemodynamic parameter

  1. Quality assurance for radon exposure chambers at the National Air and Radiation Environmental Laboratory, Montgomery, Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Semler, M.O.; Sensintaffar, E.L. [National Air and Radiation Environmental Laboratory, Montgomery, AL (United States)

    1993-12-31

    The Office of Radiation and Indoor Air, U.S. Environmental Protection Agency (EPA), operates six radon exposure chambers in its two laboratories, the National Air and Radiation Environmental Laboratory (NAREL) in Montgomery, Alabama, and the Las Vegas Facility, Las Vegas, Nevada. These radon exposure chambers are used to calibrate and test portable radon measuring instruments, test commercial suppliers of radon measurement services through the Radon Measurement Proficiency Program, and expose passive measurement devices to known radon concentrations as part of a quality assurance plan for federal and state studies measuring indoor radon concentrations. Both laboratories participate in national and international intercomparisons for the measurement of radon and are presently working with the National Institute of Standards and Technology (NIST) to receive a certificate of traceability for radon measurements. NAREL has developed an estimate of the total error in its calibration of each chamber`s continuous monitors as part of an internal quality assurance program. This paper discusses the continuous monitors and their calibration for the three chambers located in Montgomery, Alabama, as well as the results of the authors intercomparisons and total error analysis.

  2. Validation of Contamination Control in Rapid Transfer Port Chambers for Pharmaceutical Manufacturing Processes.

    Science.gov (United States)

    Hu, Shih-Cheng; Shiue, Angus; Liu, Han-Yang; Chiu, Rong-Ben

    2016-11-12

    There is worldwide concern with regard to the adverse effects of drug usage. However, contaminants can gain entry into a drug manufacturing process stream from several sources such as personnel, poor facility design, incoming ventilation air, machinery and other equipment for production, etc. In this validation study, we aimed to determine the impact and evaluate the contamination control in the preparation areas of the rapid transfer port (RTP) chamber during the pharmaceutical manufacturing processes. The RTP chamber is normally tested for airflow velocity, particle counts, pressure decay of leakage, and sterility. The air flow balance of the RTP chamber is affected by the airflow quantity and the height above the platform. It is relatively easy to evaluate the RTP chamber's leakage by the pressure decay, where the system is charged with the air, closed, and the decay of pressure is measured by the time period. We conducted the determination of a vaporized H₂O₂ of a sufficient concentration to complete decontamination. The performance of the RTP chamber will improve safety and can be completely tested at an ISO Class 5 environment.

  3. Characterizations of Cathode pad chamber as tracking detector for MUON Spectrometer of ALICE

    CERN Document Server

    Pal, Sanjoy

    The present thesis gives an overview of A Large Ion Collider Experiment (ALICE) at the Large Hadron Collider at CERN with particular emphasis on the contribution of the Indian Collaboration to the Muon Spectrometer. The two major activities of the Indian Collaboration namely, the 2$^{nd}$ Tracking Station and MANAS chip, have been covered in detail. A full scale prototype chamber (0$^{th}$ chamber) for the 2$^{nd}$ station was tested at CERN with beams from PS and SPS. Detail analysis of his data was carried out by me to validate the design and fabrication procedure for these large area Cathode Pad Chambers. This analysis also determined the production specifications of the MANAS chip. The thesis present every step which led to timely production of the ten chambers (two spare) of the 2$^{nd}$ station. At every stage strict quality control measures were adopted and various tests were carried out to validate every production step. I have been closely associated with the chamber production and all the validation...

  4. Advanced Modified High Performance Synthetic Jet Actuator with Curved Chamber

    Science.gov (United States)

    Xu, Tian-Bing (Inventor); Su, Ji (Inventor); Jiang, Xiaoning (Inventor)

    2014-01-01

    The advanced modified high performance synthetic jet actuator with optimized curvature shape chamber (ASJA-M) is a synthetic jet actuator (SJA) with a lower volume reservoir or chamber. A curved chamber is used, instead of the conventional cylinder chamber, to reduce the dead volume of the jet chamber and increase the efficiency of the synthetic jet actuator. The shape of the curvature corresponds to the maximum displacement (deformation) profile of the electroactive diaphragm. The jet velocity and mass flow rate for the ASJA-M will be several times higher than conventional piezoelectric actuators.

  5. String quartet chamber music : the personal way of music development

    OpenAIRE

    Montant, Laure

    2012-01-01

    The subject of this thesis is about chamber music and more specifically string quartet. How and why chamber music should be a real part of a musician’s life. In the introduction, it is explained why it is important to play chamber music and what qualities a musician needs to be good at it. Then a description of what is chamber music litterally is exposed. The history recounts what was chamber music from its early beginings until our days and why it has so much evolves. About interpretation, t...

  6. Premixed combustion under electric field in a constant volume chamber

    KAUST Repository

    Cha, Min Suk

    2012-12-01

    The effects of electric fields on outwardly propagating premixed flames in a constant volume chamber were experimentally investigated. An electric plug, subjected to high electrical voltages, was used to generate electric fields inside the chamber. To minimize directional ionic wind effects, alternating current with frequency of 1 kHz was employed. Lean and rich fuel/air mixtures for both methane and propane were tested to investigate various preferential diffusion conditions. As a result, electrically induced instability showing cracked structure on the flame surface could be observed. This cracked structure enhanced flame propagation speed for the initial period of combustion and led to reduction in flame initiation and overall combustion duration times. However, by analyzing pressure data, it was found that overall burning rates are not much affected from the electric field for the pressurized combustion period. The reduction of overall combustion time is less sensitive to equivalence ratio for methane/air mixtures, whereas the results demonstrate pronounced effects on a lean mixture for propane. The improvement of combustion characteristics in lean mixtures will be beneficial to the design of lean burn engines. Two hypothetical mechanisms to explain the electrically induced instability were proposed: 1) ionic wind initiated hydrodynamic instability and 2) thermodiffusive instability through the modification of transport property such as mass diffusivity. © 2012 IEEE.

  7. Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics

    CERN Document Server

    Gerstl, Stefan; Casalbuoni, Sara; Grau, Andreas; Hagelstein, Michael; Saez de Jauregui, David; Baglin, Vincent; Boffo, Cristian; Sikler, Gunther; Bradshaw, Thomas; Cimino, Roberto; Commisso, Mario; Spataro, Bruno; Clarke, James; Scott, Duncan; Cox, Matthew; Schouten, Jos; Jones, Roger; Shinton, Ian; Mostacci, Andrea; Wallen, Erik; Weigel, Ralf

    2010-01-01

    One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.

  8. Micromegas chambers for the ATLAS muon spectrometer upgrade

    CERN Document Server

    AUTHOR|(CDS)2080692; The ATLAS collaboration

    2014-01-01

    Micromegas, an abbreviation for Micro MEsh Gaseous Structure, is a robust detector with excellent spatial resolution and high rate capability. An R\\& D activity, called Muon ATLAS MicroMegas Activity (MAMMA) which was initiated in 2007 in order to explore the potential of the MM technology for use in the ATLAS experiment. After several years of prototyping and testing, the ATLAS collaboration has chosen the micromegas technology (MM) along with the small-strip Thin Gap Chambers (sTGC) for the upgrade of the inner muon station in the high-rapidity region, the so called New Small Wheel (NSW) upgrade project. It employs eight layers of MM and eight layers of sTGC detectors. The NSW project requires fully efficient micromegas chambers, able to cope with the maximum expected rate of $15\\,\\mathrm{kHz/cm^2}$ featuring spatial resolution better than $100\\,\\mu\\mathrm{m}$. The MM detectors will cover a total active area of $\\sim1200\\,\\mathrm{m^2}$ and will be operated in a moderate magnetic field with intensity up ...

  9. Dynamic consideration of smog chamber experiments

    Directory of Open Access Journals (Sweden)

    W. K. Chuang

    2017-08-01

    Full Text Available Recent studies of the α-pinene + ozone reaction that address particle nucleation show relatively high molar yields of highly oxidized multifunctional organic molecules with very low saturation concentrations that can form and grow new particles on their own. However, numerous smog-chamber experiments addressing secondary organic aerosol (SOA mass yields, interpreted via equilibrium partitioning theory, suggest that the vast majority of SOA from α-pinene is semivolatile. We explore this paradox by employing a dynamic volatility basis set (VBS model that reproduces the new-particle growth rates observed in the CLOUD experiment at CERN and then modeling SOA mass yield experiments conducted at Carnegie Mellon University (CMU. We find that the base-case simulations do overpredict observed SOA mass but by much less than an equilibrium analysis would suggest; this is because delayed condensation of vapors suppresses the apparent mass yields early in the chamber experiments. We further find that a second VBS model featuring substantial oligomerization of semivolatile monomers can match the CLOUD growth rates with substantially lower SOA mass yields; this is because the lighter monomers have a higher velocity and thus a higher condensation rate for a given mass concentration. The oligomerization simulations are a closer match to the CMU experiments than the base-case simulations, though they overpredict the observations somewhat. However, we also find that if the chemical conditions in CLOUD and the CMU chamber were identical, substantial nucleation would have occurred in the CMU experiments when in fact none occurred. This suggests that the chemical mechanisms differed in the two experiments, perhaps because the high oxidation rates in the SOA formation experiments led to rapid termination of peroxy radical chemistry.

  10. Dynamic consideration of smog chamber experiments

    Science.gov (United States)

    Chuang, Wayne K.; Donahue, Neil M.

    2017-08-01

    Recent studies of the α-pinene + ozone reaction that address particle nucleation show relatively high molar yields of highly oxidized multifunctional organic molecules with very low saturation concentrations that can form and grow new particles on their own. However, numerous smog-chamber experiments addressing secondary organic aerosol (SOA) mass yields, interpreted via equilibrium partitioning theory, suggest that the vast majority of SOA from α-pinene is semivolatile. We explore this paradox by employing a dynamic volatility basis set (VBS) model that reproduces the new-particle growth rates observed in the CLOUD experiment at CERN and then modeling SOA mass yield experiments conducted at Carnegie Mellon University (CMU). We find that the base-case simulations do overpredict observed SOA mass but by much less than an equilibrium analysis would suggest; this is because delayed condensation of vapors suppresses the apparent mass yields early in the chamber experiments. We further find that a second VBS model featuring substantial oligomerization of semivolatile monomers can match the CLOUD growth rates with substantially lower SOA mass yields; this is because the lighter monomers have a higher velocity and thus a higher condensation rate for a given mass concentration. The oligomerization simulations are a closer match to the CMU experiments than the base-case simulations, though they overpredict the observations somewhat. However, we also find that if the chemical conditions in CLOUD and the CMU chamber were identical, substantial nucleation would have occurred in the CMU experiments when in fact none occurred. This suggests that the chemical mechanisms differed in the two experiments, perhaps because the high oxidation rates in the SOA formation experiments led to rapid termination of peroxy radical chemistry.

  11. The Evolution and Development of Cephalopod Chambers and Their Shape.

    Science.gov (United States)

    Lemanis, Robert; Korn, Dieter; Zachow, Stefan; Rybacki, Erik; Hoffmann, René

    2016-01-01

    The Ammonoidea is a group of extinct cephalopods ideal to study evolution through deep time. The evolution of the planispiral shell and complexly folded septa in ammonoids has been thought to have increased the functional surface area of the chambers permitting enhanced metabolic functions such as: chamber emptying, rate of mineralization and increased growth rates throughout ontogeny. Using nano-computed tomography and synchrotron radiation based micro-computed tomography, we present the first study of ontogenetic changes in surface area to volume ratios in the phragmocone chambers of several phylogenetically distant ammonoids and extant cephalopods. Contrary to the initial hypothesis, ammonoids do not possess a persistently high relative chamber surface area. Instead, the functional surface area of the chambers is higher in earliest ontogeny when compared to Spirula spirula. The higher the functional surface area the quicker the potential emptying rate of the chamber; quicker chamber emptying rates would theoretically permit faster growth. This is supported by the persistently higher siphuncular surface area to chamber volume ratio we collected for the ammonite Amauroceras sp. compared to either S. spirula or nautilids. We demonstrate that the curvature of the surface of the chamber increases with greater septal complexity increasing the potential refilling rates. We further show a unique relationship between ammonoid chamber shape and size that does not exist in S. spirula or nautilids. This view of chamber function also has implications for the evolution of the internal shell of coleoids, relating this event to the decoupling of soft-body growth and shell growth.

  12. Anterior chamber intra ocular lens implantation.

    OpenAIRE

    Raju N

    1989-01-01

    The role of A.C. IOL in modern implant surgery has become somewhat debatable, since, the choice procedure to day is undoubtedly an ECCE with a PC lens implant preferably in the capsular bag. Even so, anterior chamber lens implantation has its definite indications. As such it is necessary for the implant surgeon to be familiar with the latest technique in this modality of surgery as well. Many of the complications of earlier rigid model AC IOLs were mainly due to defective lens design. With th...

  13. Posterior chamber intraocular lens dislocations and malpositions.

    Science.gov (United States)

    Obstbaum, S A; To, K

    1989-08-01

    Decentration and malposition of posterior chamber intraocular lenses (PC IOL) accounts for one of the remaining and unresolved conditions associated with the implantation of these lenses. This condition assumes importance since in approximately 50% of cases where a PC IOL is removed there is an aspect of improper positioning. The common types of malpositions are: pupil capture; sunset syndrome; sunrise syndrome; horizontal decentration; and the windshield wiper syndrome. This paper will explore the causes and management of these conditions and discuss the virtues of capsular bag implantation.

  14. Chamber service module (CSM1) for MDT

    CERN Document Server

    Binchi, P

    2002-01-01

    CSM-1 is the second and latest version of the high speed electronic unit whose primary task is to multiplex serial data from up to 18 ASD /TDC cards located at the ends of the Monitored Drift Tubes. Each CSM will capture data from all 24 channel TDC (AMT-2 units) of a given chamber and transfer it along a single optic fiber to the MROD, the event builder and readout driver. The core of the board is a Xilinx VirtexII FPGA which will use JTAG protocol (IEEE Std. 1149.1) for logic configuration parameter loading.

  15. Vacuum chamber for containing particle beams

    Science.gov (United States)

    Harvey, A.

    1985-11-26

    A vacuum chamber for containing a charged particle beam in a rapidly changing magnetic environment comprises a ceramic pipe with conducting strips oriented along the longitudinal axis of the pipe and with circumferential conducting bands oriented perpendicular to the longitudinal axis but joined with a single longitudinal electrical connection. When both strips and bands are on the outside of the ceramic pipe, insulated from each other, a high-resistance conductive layer such as nickel can be coated on the inside of the pipe.

  16. Liquid ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    Physik. 42, 303-344,        1913. [3]    KRAMERS, H.A.: On a modification of Jaffe's theory pf column-ionization. Physica. 10, 18,        665-675, 1952. [4]    CHU, J.C.H., GRANT, WH., ALMOND, P.R.: A liquid Ionization Chamber for neutron        dosimetry. Phys. Med. Biol. 6, 25, 1133-1148, 1980....

  17. Investigation on temperature separation and flow behaviour in vortex chamber

    Science.gov (United States)

    Matsuno, Yuhi; Fukushima, Yusuke; Matsuo, Shigeru; Hashimoto, Tokitada; Setoguchi, Toshiaki; Kim, Heuy Dong

    2015-04-01

    In the previous researches, it is known that the swirl flow in circular pipe causes the temperature separation. Recently, it is shown that the temperature separation occurs in a vortex chamber when compressed air are pumped into this device from the periphery. Especially, in a cavity installed in the periphery of the chamber, the highest temperature was observed. Therefore, it is expected that this device can be used as a heat source in the engineering field. In recent researches, the mechanism of temperature separation in vortex chamber has been investigated by some researchers. However, there are few researches for the effect of diameter and volume of vortex chamber, height of central rod and position of cavity on the temperature separation. Further, no detailed physical explanation has been made for the temperature separation phenomena in the vortex chamber. In the present study, the effects of chamber configuration and position of the cavity on temperature separation in the vortex chamber were investigated experimentally.

  18. Golden Jubilee photos: The first CERN bubble chamber

    CERN Multimedia

    2004-01-01

    In the 1950s and 1960s, bubble and spark chambers were the dominant experimental tools in high-energy physics. While spark chambers were usually built and fitted to specific experiments, bubble chambers were constructed as general purpose devices that could be used for a variety of experiments. At CERN, the bubble chamber programme started under Charles Peyrou in the late 1950s. The first of CERN's bubble chambers, a 30 cm hydrogen chamber, is seen here being inserted into its vacuum tank. The HBC30, as it was called, took its first beam from the SC in 1959. One of the first pictures taken, of a positive pion-proton interaction, began a long series of pretty images for which bubble chambers would become famous. When it stopped operating in spring 1962, the HBC30 had consumed 150 km of film in its 3 years of operation.

  19. Multigas Leakage Correction in Static Environmental Chambers Using Sulfur Hexafluoride and Raman Spectroscopy.

    Science.gov (United States)

    Jochum, Tobias; von Fischer, Joseph C; Trumbore, Susan; Popp, Jürgen; Frosch, Torsten

    2015-11-03

    In static environmental chamber experiments, the precision of gas flux measurements can be significantly improved by a thorough gas leakage correction to avoid under- or overestimation of biological activity such as respiration or photosynthesis. Especially in the case of small biological net gas exchange rates or gas accumulation phases during long environmental monitoring experiments, gas leakage fluxes could distort the analysis of the biogenic gas kinetics. Here we propose and demonstrate a general protocol for online correction of diffusion-driven gas leakage in plant chambers by simultaneous quantification of the inert tracer sulfur hexafluoride (SF6) and the investigated biogenic gases using enhanced Raman spectroscopy. By quantifying the leakage rates of carbon dioxide (CO2), methane (CH4), and hydrogen (H2) simultaneously with SF6 in the test chamber, their effective diffusivity ratios of approximately 1.60, 1.96, and 5.65 were determined, each related to SF6. Because our experiments suggest that the effective diffusivity ratios are reproducible for an individual static environmental chamber, even under varying concentration gradients and slight changes of the chamber sealing, an experimental method to quantify gas leakage fluxes by using effective diffusivity ratios and SF6 leakage fluxes is proposed. The method is demonstrated by quantifying the CO2 net exchange rate of a plant-soil ecosystem (Mirabilis jalapa). By knowing the effective chamber diffusivity ratio CO2/SF6 and the measured SF6 leakage rate during the experiment, the leakage contribution to the total CO2 exchange rate could be calculated and the biological net CO2 concentration change within the chamber atmosphere determined.

  20. Operation of high rate microstrip gas chambers

    CERN Document Server

    Barr, A J; Bouclier, Roger; Capéans-Garrido, M; Dominik, Wojciech; Manzin, G; Million, Gilbert; Hoch, M; Ropelewski, Leszek; Sauli, Fabio; Sharma, A

    1996-01-01

    We describe recent measurements carried out in well controlled and reproducible conditions to help understanding the factors affecting the short and long term behaviour of Microstrip Gas Chambers. Special care has been taken concerning the gas purity and choice of materials used in the system and for the detectors construction. Detectors built on glasses with surface resistivity in the range $10^{13}-10^{15} \\Omega/\\Box$ have shown satisfactory performance as they do not show charging-up process at high rate and stand the large doses required for the future high luminosity experiments (~10 mC·cm-1·yr-1). Concerning the lifetime measurements, it has been observed that chambers manufactured on high-resistivity glass are far more susceptible of suffering ageing than detectors made on low resistivity, electron-conducting supports, independently of the metal used for the artwork (chromium or gold) at least in clean gas conditions. The successfully operation in the laboratory of detectors manufactured on diamond-...

  1. BEBC, the Big European Bubble Chamber

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    The vessel of the Big European Bubble Chamber, BEBC, was installed at the beginning of the 1970s. The large stainless-steel vessel, measuring 3.7 metres in diameter and 4 metres in height, was filled with 35 cubic metres of liquid (hydrogen, deuterium or a neon-hydrogen mixture), whose sensitivity was regulated by means of a huge piston weighing 2 tonnes. During each expansion, the trajectories of the charged particles were marked by a trail of bubbles, where liquid reached boiling point as they passed through it. The first images were recorded in 1973 when BEBC, equipped with the largest superconducting magnet in service at the time, first received beam from the PS. In 1977, the bubble chamber was exposed to neutrino and hadron beams at higher energies of up to 450 GeV after the SPS came into operation. By the end of its active life in 1984, BEBC had delivered a total of 6.3 million photographs to 22 experiments devoted to neutrino or hadron physics. Around 600 scientists from some fifty laboratories through...

  2. Translimbal fixation of posterior chamber lenses.

    Science.gov (United States)

    Yospaiboon, Yosanan; Wongwai, Pantipa; Ratanapakorn, Tanapat; Sinawat, Suthasinee

    2005-11-01

    To evaluate the result of a surgical technique to insert and secure a standard posterior chamber lens through a simple limbal incision in eyes that had no capsular support or whose capsule was inadvertently ruptured during extracapsular cataract extraction. Retrospective review of the medical records of patients who underwent translimbal fixation of posterior chamber lenses according to age, gender, preoperative visual acuity, postoperative visual acuity, follow-up period and any complications, especially those that may be related to the surgical technique. Twelve patients were recruited in the present study. The patents' age ranged from 31 to 77 years, with a mean of 62.58 years. There were 9 male and 3 female patients. The preoperative visual acuity ranged from hand motion to counting fingers, and the postoperative visual acuity ranged from 6/6 to 6/24 except one patient who had postoperative visual acuity of counting fingers due to a pre-existing macular hole. The length of follow-up period ranged from 3 to 12 months, with a mean of 6.17 months. There was no clinically significant lens-related complication. This simple surgical technique controls the location of the needle entry and exit to decrease the risk of bleeding and increase the chance of ciliary sulcus placement. An inferior groove was made to bury the suture knot and was sutured closed to prevent the knot erosion through the conjunctiva.

  3. Suppressing drift chamber diffusion without magnetic field

    CERN Document Server

    Martoff, C J; Ohnuki, T; Spooner, N J C; Lehner, M

    2000-01-01

    The spatial resolution in drift chamber detectors for ionizing radiation is limited by diffusion of the primary electrons. A strong magnetic field along the drift direction is often applied (Fancher et al., Nucl. Instr. and Meth. A 161 (1979) 383) because it suppresses the transverse diffusion, improving the resolution but at considerable increase in cost and complexity. Here we show that transverse track diffusion can be strongly suppressed without any magnetic field. This is achieved by using a gas additive which reversibly captures primary ionization electrons, forming negative ions. The ions drift with thermal energies even at very high drift fields and low pressures (E/P=28.5 V/cm torr), and the diffusion decreases with increasing drift field. Upon arrival at the avalanche region of the chamber the negative ions are efficiently stripped and ordinary avalanche gain is obtained. Using this technique, r.m.s. transverse diffusion less than 200 mu m has been achieved over a 15 cm drift path at 40 torr with ze...

  4. Prototype for the ALEPH Time Projection Chamber

    CERN Multimedia

    1980-01-01

    This is a prototype endplate piece constructed during R&D for the ALEPH Time Projection Chamber (TPC). ALEPH was one of 4 experiments at CERN's 27km Large Electron Positron collider (LEP) that ran from 1989 to 2000. ALEPH's TPC was a large-volume tracking chamber, 4.4 metres long and 3.6 metres in diameter - the largest TPC in existance at the time. This object is one of the endplates of a “Kind” sector, the smallest of the three types of sectors. The patterns etched into the copper form the cathode pads that measured particle track coordinates in the r-phi direction. It included a laser calibration system, a gating system to prevent space charge buildup, and a new radial pad geometry to improve resolution. the ALEPH TPC allowed for precise momentum measurements of the high-momentum particles from W and Z decays. The following institutes participated: CERN, Athens, Glasgow, Mainz, MPI Munich, INFN-Pisa, INFN-Trieste, Wisconsin.

  5. Report on Fission Time Projection Chamber M3FT-12IN0210052

    Energy Technology Data Exchange (ETDEWEB)

    James K. Jewell

    2012-08-01

    The Time Projection Chamber is a collaborative effort to implement an innovative approach and deliver unprecedented fission measurements to DOE programs. This 4?-detector system will provide unrivaled 3-D data about the fission process. Shown here is a half populated TPC (2?) at the LLNL TPC laboratory as it undergoes testing before being shipped to LANSCE for beam experiments.

  6. FULL-SCALE CHAMBER INVESTIGATION AND SIMULATION OF AIR FRESHENER EMISSIONS IN THE PRESENCE OF OZONE

    Science.gov (United States)

    The paper discusses results of tests, conducted in the EPA large chamber facility, determining emissions and chemical degradation of volatile organic compounds (VOCs) from one electrical plug-in type pine-scented air freshener in the presence of ozone supplied by a device markete...

  7. Electromagnetic Compatibility Testing Studies

    Science.gov (United States)

    Trost, Thomas F.; Mitra, Atindra K.

    1996-01-01

    This report discusses the results on analytical models and measurement and simulation of statistical properties from a study of microwave reverberation (mode-stirred) chambers performed at Texas Tech University. Two analytical models of power transfer vs. frequency in a chamber, one for antenna-to-antenna transfer and the other for antenna to D-dot sensor, were experimentally validated in our chamber. Two examples are presented of the measurement and calculation of chamber Q, one for each of the models. Measurements of EM power density validate a theoretical probability distribution on and away from the chamber walls and also yield a distribution with larger standard deviation at frequencies below the range of validity of the theory. Measurements of EM power density at pairs of points which validate a theoretical spatial correlation function on the chamber walls and also yield a correlation function with larger correlation length, R(sub corr), at frequencies below the range of validity of the theory. A numerical simulation, employing a rectangular cavity with a moving wall shows agreement with the measurements. The determination that the lowest frequency at which the theoretical spatial correlation function is valid in our chamber is considerably higher than the lowest frequency recommended by current guidelines for utilizing reverberation chambers in EMC testing. Two suggestions have been made for future studies related to EMC testing.

  8. LHCb: Design of a Highly Optimised Vacuum Chamber Support for the LHCb Experiment

    CERN Multimedia

    Leduc, L; Veness, R

    2011-01-01

    The beam vacuum chamber in the LHCb experimental area passes through the centre of a large aperture dipole magnet. The vacuum chamber and all its support systems lie in the acceptance of the detector, so must be highly optimised for transparency to particles. As part of the upgrade programme for the LHCb vacuum system, the support system has been re-designed using advanced lightweight materials. In this paper we discuss the physics motivation for the modifications, the criteria for the selection of materials and tests performed to qualify them for the particular environment of a particle physics experiment. We also present the design of the re-optimised support system.

  9. Rate-dependent performance of ion chambers for particle-ID at the GSI fragment separator

    Energy Technology Data Exchange (ETDEWEB)

    Hucka, Jan-Paul; Allred, Timothy; Enders, Joachim [Institut fuer Kernphysik, TU Darmstadt (Germany); Gernhaeuser, Roman; Maurus, Steffen [Physik Department, TU Muenchen (Germany); Nociforo, Chiara; Pietri, Stephane; Prochazka, Andrej [GSI Helmholtzzentrum fuer Schwerionenforschung (Germany)

    2015-07-01

    At the GSI Fragment Separator (FRS), multi-sampling ion chambers (MUSIC) employing a Frisch grid are used for charge identification of secondary ion beams. At the FAIR Super-FRS, higher rates are expected, and an event-by-event determination of the charge of secondary ions will be needed at rates of several 100000 events per second. The comparison of results from test measurements for the MUSIC performance with that of a recently constructed tilted-electrode gas ion chamber (TEGIC), which was designed similar to the one discussed, is presented.

  10. Long-term performance of double gap resistive plate chambers under gamma irradiation

    CERN Document Server

    Abbrescia, M; Guarrasi, L; Iaselli, Giuseppe; Loddo, F; Maggi, M; Marangelli, B; Natali, S; Nuzzo, S; Pugliese, G; Ranieri, A; Romano, F; Altieri, S; Belli, G; Bruno, G; Gianini, G; Ratti, S P; Riccardi, C; Torre, P; Viola, L; Vitulo, P

    2002-01-01

    In this paper, we describe a dedicated test to study possible long- term aging effects on Resistive Plate Chambers (RPCs). A double gap detector was operated under gamma irradiation for a period approximately equal to 10 years of LHC in the CMS-barrel region: an integrated dose of about 1.6 Gy and a total charge of about 0.05 C/cm /sup 2/ gap were accumulated on the chamber. The results show no relevant aging effect. Also the RPC sensitivity to /sup 60/Co gamma energies is measured. (9 refs).

  11. Development and evaluation of a Monte Carlo Code System for analysis of ionization chamber responses

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, J.O.; Gabriel, T.A.

    1987-07-01

    This document reports on the development and testing of a Monte Carlo code system for calculating the response of an ionization chamber to mixed neutron and photon radiation environment. The code system, Monte Carlo Ionization Chamber Analysis Package (MICAP), determines the neutron, photon, and total responses of the ionization chamber to the mixed field radiation environment. The Monte Carlo method performs accurate simulations of the physical processes involved in detecting radiation using ionization chambers, and eliminates limitations inherent in approximate methods. To evaluate MICAP, comparisons were made with results obtained using other code systems and with experimental results. Separate comparisons with other code systems verified the validity of the neutron, photon, and charged particle transport processes and the nuclear models used to describe the individual neutron reactions, respectively. Comparisons with mono-energetic photon calibration experiments and with mixed neutron and photon radiation experiments verified the applicability of MICAP for analyzing the response of ionization chambers to mixed field radiation environments. 47 refs., 23 figs., 20 tabs.

  12. Degradation in the efficiency of glass Resistive Plate Chambers operated without external gas supply

    Science.gov (United States)

    Baesso, P.; Cussans, D.; Thomay, C.; Velthuis, J.; Burns, J.; Quillin, S.; Stapleton, M.; Steer, C.

    2015-06-01

    Resistive plate chambers (RPC) are particle detectors commonly used by the high energy physics community. Their normal operation requires a constant flow of gas mixture to prevent self-poisoning which reduces the chamber's capability to detect particles. We studied how quickly the efficiency of two RPCs drops when operated in sealed mode, i.e. without refreshing the gas mixture. The test aim is to determine how RPCs could be used as particle detectors in non-laboratory applications, such as those exploiting muon tomography for geological imaging or homeland security. The two sealed RPCs were operated in proportional mode for a period of more than three months, and their efficiencies were recorded continuously and analysed in 8-hours intervals. The results show that the efficiency drops on average by 0.79 ± 0.01 % every 24 hours of operation and returns close to the initial value after purging the old gas mixture and flushing the chambers with fresh gas.

  13. Elimination of Intermediate-Frequency Combustion Instability in the Fastrac Engine Thrust Chamber

    Science.gov (United States)

    Rocker, Marvin; Nesman, Tomas E.; Turner, Jim E. (Technical Monitor)

    2001-01-01

    A series of tests were conducted to measure the combustion performance of the Fastrac engine thrust chamber. The thrust chamber exhibited benign, yet marginally unstable combustion. The marginally unstable combustion was characterized by chamber pressure oscillations with large amplitudes and a frequency that was too low to be identified as acoustic or high-frequency combustion instability and too high to be identified as chug or low-frequency combustion instability. The source of the buzz or intermediate-frequency combustion instability was traced to the fuel venturi whose violently noisy cavitation caused resonance in the feedline downstream. Combustion was stabilized by increasing the throat diameter of the fuel venturi such that the cavitation would occur more quietly.

  14. Resistive Plate Chambers commissioning and performance results for 2011-2013.

    CERN Document Server

    CMS Collaboration

    2014-01-01

    Resistive Plate Chambers (RPC) performance results for the period between 2011-2013 are presented. These results include history plots for the RPC relevant variables such as: Cluster Size, Efficiency, percentage of inactive detector during operation, Rates, and Currents. RPC variables are studied as function of relevant parameters such as the averaged instantaneous luminosity of the LHC, time, and CMS cavern pressure. Results obtained with the monitoring tools used by CMS such as the Web Based Monitoring tool (WBM) are also shown. RPC Background rates measured during 2010, 2011, and 2012 are presented and compared. Preparations for the 2015 Run include the installation of a new couple of disks of RPCs in the endcap regions, results obtained during quality control campaigns for the new RPCs are also presented, these results include High voltage scans that probe the quality and standards of the RPC construction procedures, as well as tests on chamber gas leaks and current behavior for the new chambers. Basic p...

  15. The STREON Recirculation Chamber: An Advanced Tool to Quantify Stream Ecosystem Metabolism in the Benthic Zone

    Science.gov (United States)

    Brock, J. T.; Utz, R.; McLaughlin, B.

    2013-12-01

    The STReam Experimental Observatory Network is a large-scale experimental effort that will investigate the effects of eutrophication and loss of large consumers in stream ecosystems. STREON represents the first experimental effort undertaken and supported by the National Ecological Observatory Network (NEON).Two treatments will be applied at 10 NEON sites and maintained for 10 years in the STREON program: the addition of nitrate and phosphate to enrich concentrations by five times ambient levels and electrical fields that exclude top consumers (i.e., fish or invertebrates) of the food web from the surface of buried sediment baskets. Following a 3-5 week period, the sediment baskets will be extracted and incubated in closed, recirculating metabolic chambers to measure rates of respiration, photosynthesis, and nutrient uptake. All STREON-generated data will be open access and available on the NEON web portal. The recirculation chamber represents a critical infrastructural component of STREON. Although researchers have applied such chambers for metabolic and nutrient uptake measurements in the past, the scope of STREON demands a novel design that addresses multiple processes often neglected by earlier models. The STREON recirculation chamber must be capable of: 1) incorporating hyporheic exchange into the flow field to ensure measurements of respiration include the activity of subsurface biota, 2) operating consistently with heterogeneous sediments from sand to cobble, 3) minimizing heat exchange from the motor and external environment, 4) delivering a reproducible uniform flow field over the surface of the sediment basket, and 5) efficient assembly/disassembly with minimal use of tools. The chamber also required a means of accommodating an optical dissolved oxygen probe and a means to inject/extract water. A prototype STREON chamber has been designed and thoroughly tested. The flow field within the chamber has been mapped using particle imaging velocimetry (PIV

  16. Beam Measurements of a CLOUD (Cosmics Leaving OUtdoor Droplets) Chamber

    CERN Document Server

    Kirkby, Jasper

    2001-01-01

    A striking correlation has recently been observed between global cloud cover and the flux of incident cosmic rays. The effect of natural variations in the cosmic ray flux is large, causing estimated changes in the Earth's energy radiation balance that are comparable to those attributed to greenhouse gases from the burning of fossil fuels since the Industrial Revolution. However a direct link between cosmic rays and cloud formation has not been unambiguously established. We therefore propose to experimentally measure cloud (water droplet) formation under controlled conditions in a test beam at CERN with a CLOUD chamber, duplicating the conditions prevailing in the troposphere. These data, which have never been previously obtained, will allow a detailed understanding of the possible effects of cosmic rays on clouds and confirm, or otherwise, a direct link between cosmic rays, global cloud cover and the Earth's climate. The measurements will, in turn, allow more reliable calculations to be made of the residual e...

  17. Development of a Micro Pixel Chamber for the ATLAS Upgrade

    CERN Document Server

    Ochi, Atsuhiko; Komai, Hidetoshi; Edo, Yuki; Yamaguchi, Takahiro

    2012-01-01

    The Micro Pixel Chamber (μ-PIC) is being developed a sacandidate for the muon system of the ATLAS detector for upgrading in LHC experiments. The μ-PIC is a micro-pattern gaseous detector that doesn’t have floating structure such as wires, mesh, or foil. This detector can be made by printed-circuit-board (PCB) technology, which is commercially available and suited for mass production. Operation tests have been performed under high flux neutrons under similar conditions to the ATLAS cavern. Spark rates are measured using several gas mixtures under 7 MeV neutron irradiation, and good properties were observed using neon, ethane, and CF4 mixture of gases.Using resistive materials as electrodes, we are also developing a new μ-PIC, which is not expected to damage the electrodes in the case of discharge sparks.

  18. Gas mixture studies for streamer operated Resistive Plate Chambers

    Science.gov (United States)

    Paoloni, A.; Longhin, A.; Mengucci, A.; Pupilli, F.; Ventura, M.

    2016-06-01

    Resistive Plate Chambers operated in streamer mode are interesting detectors in neutrino and astro-particle physics applications (like OPERA and ARGO experiments). Such experiments are typically characterized by large area apparatuses with no stringent requirements on detector aging and rate capabilities. In this paper, results of cosmic ray tests performed on a RPC prototype using different gas mixtures are presented, the principal aim being the optimization of the TetraFluoroPropene concentration in Argon-based mixtures. The introduction of TetraFluoroPropene, besides its low Global Warming Power, is helpful because it simplifies safety requirements allowing to remove also isobutane from the mixture. Results obtained with mixtures containing SF6, CF4, CO2, N2 and He are also shown, presented both in terms of detectors properties (efficiency, multiple-streamer probability and time resolution) and in terms of streamer characteristics.

  19. Progress with diamond over-coated microstrip gas chambers

    CERN Document Server

    Boimska, B; Capéans-Garrido, M; Dominik, Wojciech; Million, Gilbert; Ropelewski, Leszek; Sauli, Fabio; Sharma, A; Temmel-Ropelewski, T

    1998-01-01

    We describe recent observations and measurements with Micro-Strip Gas Chambers coated, after manufacturing, with a thin diamond-like layer in order to increase their rate capability. Compared to the more widely used solution consisting in coating the insulating support with a conductive layer before photo-lithography (the so-called undercoating), over-coating has the advantage of avoiding possible problems with adherence of metals to the layer, damages during the etching process and reduced quality of the artwork resulting from imperfections or dust inclusions in the layer. Early tests have however indicated that, possibly because of damages to the layer due to electron and ion bombardment during the avalanche process, irreversible structural modifications and fatal breakdown could be encountered at very high integral radiation fluxes. The present paper summarizes these results, and describes recent developments demonstrating that a better choice of the parameters of the over-coat may allow to withstand the r...

  20. Readout of TPC Tracking Chambers with GEMs and Pixel Chip

    Energy Technology Data Exchange (ETDEWEB)

    Kadyk, John; Kim, T.; Freytsis, M.; Button-Shafer, J.; Kadyk, J.; Vahsen, S.E.; Wenzel, W.A.

    2007-12-21

    Two layers of GEMs and the ATLAS Pixel Chip, FEI3, have been combined and tested as a prototype for Time Projection Chamber (TPC) readout at the International Linear Collider (ILC). The double-layer GEM system amplifies charge with gain sufficient to detect all track ionization. The suitability of three gas mixtures for this application was investigated, and gain measurements are presented. A large sample of cosmic ray tracks was reconstructed in 3D by using the simultaneous timing and 2D spatial information from the pixel chip. The chip provides pixel charge measurement as well as timing. These results demonstrate that a double GEM and pixel combination, with a suitably modified pixel ASIC, could meet the stringent readout requirements of the ILC.