WorldWideScience

Sample records for test beam results

  1. Results from ATLAS Calorimeter Combined Test Beam

    CERN Document Server

    Tarrade, F

    2007-01-01

    Beam tests of combinations of ATLAS calorimeters have been performed both for the barrel and end cap parts. During a combined test beam in summer 2004 a slice of the ATLAS barrel detector - including all detector sub systems from the inner tracker, the calorimetry to the muon system - was exposed to particle beams (electrons, pions, photons, muons) with different energies (1GeV to 350GeV). The aim was to study the combined performance of the different detector sub systems in ATLAS-like conditions. We will present the electronics calibration scheme of the electromagnetic calorimeter and its implementation. The following studies on the combined testbeam data have been performed and will be presented: performance of the electromagnetic calorimetry down to very low energies (> GeV), photon reconstruction including converted photons and position measurements using the very precise ATLAS tracker and the electromagnetic calorimeter. These measurements have been compared to Monte Carlo simulations showing the good de...

  2. Results from the 1999 Beam Test of a Preshower Prototype

    CERN Document Server

    Aspell, Paul; Bloch, Philippe; Bourotte, Jean; Domeniconi, Jacques; Peisert, Anna; Evangelou, Ioannis; Kloukinas, Kostas; Kyriakis, Aristotelis; Loos, Robert; Loukas, Demetrios; Mousa, Jehad; Peron, Franck; Reynaud, Serge; Sirunyan, Albert M; Tournefier, Edwige; Van Hove, Alain; Zamiatin, Nikolai

    2000-01-01

    At the end of June 1999 a test of a preshower prototype, equipped with real-size detectors and LHC-style electronics, was tested in the H4 beam at CERN in front of a matrix of "Endcap" crystals. Data were taken with a variety of incident electron energies, and three angles of incidence ( to simulate different regions of the CMS endcaps). The prototype functioned well, with a very small startup period and operated successfully for the duration of the test ( ~ 1 week) without intervention. Good agreement has been found between data and a GEANT-3 based simulation, and the absolute results are promising. Plans are presented for a further test of the prototype in 2000 in the H2 beam inside the 3T magnet.

  3. Test beam results from the CMS electromagnetic calorimeter

    CERN Document Server

    Brunelière, R

    2004-01-01

    A precision lead tungstate crystal calorimeter is being constructed by the CMS collaboration. As a key part of the future CMS detector at the LHC, the electromagnetic calorimeter will play a major role in probing electroweak symmetry-breaking and searches for new physics. In order to check that the required performance of the electromagnetic calorimeter is attainable, every prototype is tested in real conditions within a beam of particles. In 2003 two modules of the electromagnetic calorimeter featuring the final mechanical design and electronic architecture have been tested with two different versions of the front-end electronics. In this paper a review of the main results of test beam campaigns in 2002 and 2003 are given. (7 refs).

  4. Planar Pixel Sensors for the ATLAS Upgrade: Beam Tests results

    CERN Document Server

    Weingarten, J

    2012-01-01

    The performance of planar silicon pixel sensors, in development for the ATLAS Insertable B-Layer and High Luminosity LHC (HL-LHC) upgrades, has been examined in a series of beam tests at the CERN SPS facilities since 2009. Salient results are reported on the key parameters, including the spatial resolution, the charge collection and the charge sharing between adjacent cells, for different bulk materials and sensor geometries. Measurements are presented for n+-in-n pixel sensors irradiated with a range of fluences and for p-type silicon sensors with various layouts from different vendors. All tested sensors were connected via bump-bonding to the ATLAS Pixel read-out chip. The tests reveal that both n-type and p-type planar sensors are able to collect significant charge even after the lifetime fluence expected at the HL-LHC.

  5. Performance of CREAM Calorimeter Results of Beam Tests

    CERN Document Server

    Ahn, H S; Beatty, J J; Bigongiari, G; Castellina, A; Childers, J T; Conklin, N B; Coutu, S; Duvernois, M A; Ganel, O; Han, J H; Hyun, H J; Kang, T G; Kim, H J; Kim, K C; Kim, M Y; Kim, T; Kim, Y J; Lee, J K; Lee, M H; Lutz, L; Maestro, P; Malinine, A; Marrocchesi, P S; Mognet, S I; Nam, S W; Nutter, S; Park, N H; Park, H; Seo, E S; Sina, R; Syed, S; Song, C; Swordy, S; Wu, J; Yang, J; Zhang, H Q; Zei, R; Zinn, S Y

    2005-01-01

    The Cosmic Ray Energetics And Mass (CREAM), a balloon-borne experiment, is under preparation for a flight in Antarctica at the end of 2004. CREAM is planned to measure the energy spectrum and composition of cosmic rays directly at energies between 1 TeV and 1000 TeV. Incident particle energies will be measured by a transition radiation detector and a sampling calorimeter. The calorimeter was constructed at the University of Maryland and tested at CERN in 2003. Performance of the calorimeter during the beam tests is reported.

  6. 3D silicon pixel sensors: Recent test beam results

    CERN Document Server

    Hansson, P; Sandaker, H; Korolkov, I; Barrera, C; Wermes, N; Borri, M; Grinstein, S; Troyano, I; Grenier, P; Devetak, E; Fleta, C; Kenney, C; Tsybychev, D; Nellist, C; Chmeissan, M; Su, D; DeWilde, B; Silverstein, D; Dorholt, O; Tsung, J; Sjoebaek, K; Stupak, J; Slaviec, T; Micelli, A; Helle, K; Bolle, E; Huegging, F; Kocian, M; Fazio, S; Balbuena, J; Dalla Betta, G F; La Rosa, A; Rivero, F; Mastroberardino, A; Hasi, J; Darbo, G; Boscardin, M; Da Via, C; Nordahl, P; Giordani, M; Jackson, P; Rohne, O; Gemme, C; Young, C

    2011-01-01

    The 3D silicon sensors aimed for the ATLAS pixel detector upgrade have been tested with a high energy pion beam at the CERN SPS in 2009. Two types of sensor layouts were tested: full-3D assemblies fabricated in Stanford, where the electrodes penetrate the entire silicon wafer thickness, and modified-3D assemblies fabricated at FBK-irst with partially overlapping electrodes. In both cases three read-out electrodes are ganged together to form pixels of dimension 50 x 400 mu m(2). Data on the pulse height distribution, tracking efficiency and resolution were collected for various particle incident angles, with and without a 1.6 T magnetic field. Data from a planar sensor of the type presently used in the ATLAS detector were used at the same time to give comparison. Published by Elsevier B.V.

  7. Test Beam Results with a Full Size sTGC

    CERN Document Server

    Rettie, Sebastien; The ATLAS collaboration

    2014-01-01

    The forthcoming LHC upgrade to high luminosity will increase the background rate in the forward region of the ATLAS Muon Spectrometer (composed of three Big Wheels (BW) and a Small Wheel (SW) on each side of the detector) by approximately a factor of five. With such a rate some of the present Muon Spectrometer detectors in the SW region will produce fake triggers and will therefore be replaced by a New Small Wheel (NSW) composed of small Thin Gap Chamber (sTGC) and Micromegas planes. The aim of the detectors is to reach 100 micrometers position resolution and an online muon track reconstruction with better than 1 mrad precision. A full size sTGC quadruplet has been constructed and equipped with the first prototype of the dedicated front end electronics (VMM1). The performance of the sTGC quadruplet at the Fermilab test beam facility is presented here.

  8. BeamCal Instrumentation IC: Design, Implementation, and Test Results

    Science.gov (United States)

    Abusleme, Angel; Dragone, Angelo; Haller, Gunther; Wooley, Bruce A.

    2012-06-01

    The BeamCal detector, one of the calorimeters in the forward region of the International Linear Collider detector, will serve three purposes: ensure hermeticity of the detector for small polar angles, reduce the backscattering from beamstrahlung electron-positron pairs into the detector center, and provide a low-latency signal for beam diagnostics. The BeamCal specifications in terms of noise suppression, signal charge, pulse rate, and occupancy pose unique challenges in the front end and readout electronics design. The Bean-BeamCal instrumentation IC is the integrated circuit under study to fulfill these requirements. To process the signal charge at the International Collider pulse rate, the Bean uses switched-capacitor filters and a slow reset-release technique. Each channel has a 10-bit successive approximation analog-to-digital converter. The Bean also features a fast feedback adder capable of providing a low latency output for beam diagnostic purposes. This work presents the design and characterization of a 3-channel prototype of the Bean built to validate concepts while the final device will comprise 32 channels.

  9. Results from the beam test of the engineering model of the GLAST large area telescope

    Energy Technology Data Exchange (ETDEWEB)

    Couto e Silva, E. do E-mail: eduardo@slac.stanford.edu; Anthony, P.; Arnold, R.; Arrighi, H.; Bloom, E.; Baughman, B.; Bogart, J.; Bosted, P.; Bumala, B.; Chekhtman, A.; Cotton, N.; Crider, A.; Dobbs-Dixon, I.; Djannati-Atai, A.; Dubois, R.; Engovatov, D.; Espigat, P.; Evans, J.L.; Fieguth, T.; Flath, D.; Frigaard, M.; Giebels, B.; Gillespie, S.; Godfrey, G.; Grove, J.E.; Handa, T.; Hansl-Kozanecka, T.; Hernando, J.; Hicks, M.; Hirayama, M.; Johnson, W.N.; Johnson, R.; Kamae, T.; Kroeger, W.; Lauben, D.; Lin, Y.C.; Lindner, T.; Michelson, P.; Moiseev, A.; Nikolaou, M.; Nolan, P.; Odian, A.; Ohsugi, T.; Ormes, J.; Paliaga, G.; Parkinson, P. Saz; Phlips, B.; Ritz, S.; Rock, S.; Russel, J.J.; Sadrozinski, H.; Schalk, T.; Silvis, J.; Szalata, Z.; Terrier, R.; Thompson, D.J.; Tournear, D.M.; Waite, A.P.; Wallace, J.; Williams, S.; Williamson, R.; Winker, G

    2001-11-21

    This paper describes the results of a beam test using the Engineering Model of the GLAST Large Area Telescope, which was installed in a beam of positrons, hadrons and tagged photons at SLAC. The performance of the four subsystems, Anti Coincidence Detector, Silicon Tracker, Calorimeter and Data Acquisition will be described.

  10. Results from the Beam Test of the Engineering Model of the GLAST Large Area Telescope

    Energy Technology Data Exchange (ETDEWEB)

    do Couto e Silva, Eduardo

    2000-11-03

    This paper describes the results of a beam test using the Engineering Model of the GLAST Large Area Telescope, which was installed in a beam of positrons, hadrons and tagged photons at SLAC. The performance of the four subsystems, Anti Coincidence Detector, Silicon Tracker, Calorimeter and Data Acquisition will be described.

  11. The Cherenkov correlated timing detector beam test results from quartz and acrylic bars

    CERN Document Server

    Sugaya, Y; Yoshimura, Y; Kanda, S; Olsen, S; Ueno, K; Varner, G S; Bergfeld, T; Bialek, J J; Lorenc, J; Palmer, M; Rudnick, G; Selen, M; Auran, T; Boyer, V; Honscheid, K; Tamura, N; Yoshimura, K; Lü, C; Marlow, D R; Mindas, C R; Prebys, E J; Asai, M; Kimura, A; Hayashi, S

    1995-01-01

    Several prototypes of a Cherenkov Correlated Timing (CCT) Detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype.

  12. Test Beam Results of Multi-Geometry Prototype Sensors for the LHCb Inner Tracker

    CERN Document Server

    Agari, M; Carron, B; Heule, S; Jiménez-Otero, S; Lehner, F; Ludwig, A; Pugatch, V; Schmelling, M; Sievers, P; Steinkamp, O; Straumann, U; Tran, M T; Vollhardt, A; Voss, H

    2002-01-01

    Multi-geometry silicon prototype sensors designed for the LHCb Inner Tracker have been studied in a test beam performed in the X7 beam line at CERN in May 2002. Measurements were made using the Beetle 1.1 analogue front-end chip and a sampling at 40 MHz. In this note results on resolution, signal-to-noise, noise rates and efficiencies are presented as function of the bias voltage and for different shaping times. Based on these results a decision will be made on which geometry will be implemented in the final sensors for the LHCb Inner Tracker.

  13. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Bambade, P; Amann, J; Angal-Kalinin, D; Apsimon, R; Araki, S; Aryshev, A; Bai, S; Bellomo, P; Bett, D; Blair, G; Bolzon, B; Boogert, S; Boorman, G; Burrows, P N; Christian, G; Coe, P; Constance, B; Delahaye, J P; Deacon, L; Elsen, E; Faus-Golfe, A; Fukuda, M; Gao, J; Geffroy, N; Gianfelice-Wendt, E; Guler, H; Hayano, H; Heo, A Y; Honda, Y; Huang, J Y; Hwang, W H; Iwashita, Y; Jeremie, A; Jones, J; Kamiya, Y; Karataev, P; Kim, E S; Kim, H S; Kim, S H; Komamiya, S; Kubo, K; Kume, T; Kuroda, S; Lam, B; Lyapin, A; Masuzawa, M; McCormick, D; Molloy, S; Naito, T; Nakamura, T; Nelson, J; Okamoto, D; Okugi, T; Oroku, M; Park, Y J; Parker, B; Paterson, E; Perry, C; Pivi, M; Raubenheimer, T; Renier, Y; Resta-Lopez, J; Rimbault, C; Ross, M; Sanuki, T; Scarfe, A; Schulte, D; Seryi, A; Spencer, C; Suehara, T; Sugahara, R; Swinson, C; Takahashi, T; Tauchi, T; Terunuma, N; Tomas, R; Urakawa, J; Urner, D; Verderi, M; Wang, M H; Warden, M; Wendt, M; White, G; Wittmer, W; Wolski, A; Woodley, M; Yamaguchi, Y; Yamanaka, T; Yan, Y; Yoda, H; Yokoya, K; Zhou, F; Zimmermann, F; 10.1103/PhysRevSTAB.13.042801

    2010-01-01

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  14. First test beam results of prototype modules for the upgrade of the ATLAS strip tracking detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00218553; The ATLAS collaboration

    2016-01-01

    The LHC is foreseen to be upgraded to the High-Luminosity LHC (HL-LHC). This will result in higher particle rates and radiation doses. The ATLAS experiment plans to replace its inner tracking detector by a new all-silicon tracker which is based on the concept of modularity. For the new silicon strip tracker a large prototyping and evaluation campaign is ongoing. Many modules of different types were built and tested both in the laboratories and in test beams. In the following first results obtained in test beams are presented. Both mini and full-size modules for the central and forward regions were tested before and after irradiation to fluences as expected at the HL-LHC.

  15. Recent Results from Beam Tests of 3D and Pad pCVD Diamond Detectors

    CERN Document Server

    Wallny, Rainer

    2017-01-01

    Results from prototypes of a detector using chemical vapor deposited (CVD) diamond with embedded resistive electrodes in the bulk forming a 3D diamond device are presented. A detector system consisting of 3D devices based on poly-crystalline CVD (pCVD) diamond was connected to a multi-channel readout and successfully tested in a 120 GeV/c proton beam at CERN proving for the first time the feasibility of the 3D detector concept in pCVD for particle tracking applications. We also present beam test results on the dependence of signal size on incident particle rate in charged particle detectors based on poly-crystalline CVD diamond. The detectors were tested in a 260 MeV/c pion beam over a range of particle fluxes from 2 kHz/cm2 to 10 MHz/cm2 . The pulse height of the sensors was measured with pad readout electronics at a peaking time of 7 ns. Our data from the 2015 beam tests at PSI indicate that the pulse height of poly-crystalline CVD diamond sensor irradiated to 5×1014 neq/cm2 is independent of particle flux...

  16. Beam test results of the irradiated Silicon Drift Detector for ALICE

    OpenAIRE

    Kushpil, S.; Crescio, E; Giubellino, P.; Idzik, M.; Kolozhvari, A; Kushpil, V.; Martinez, M.I.; Mazza, G; Mazzoni, A.; Meddi, F.; Nouais, D; Petracek, V; Piemonte, C; Rashevsky, A; Riccati, L

    2005-01-01

    The Silicon Drift Detectors will equip two of the six cylindrical layers of high precision position sensitive detectors in the ITS of the ALICE experiment at LHC. In this paper we report the beam test results of a SDD irradiated with 1 GeV electrons. The aim of this test was to verify the radiation tolerance of the device under an electron fluence equivalent to twice particle fluence expected during 10 years of ALICE operation.

  17. Beam test results of a drift velocity monitoring system for silicon drift detectors

    CERN Document Server

    Nouais, D; Bonvicini, V; Cerello, P; Giubellino, P; Hernández-Montoya, R; Kolojvari, A; Mazza, G; Nissinen, J; Rashevsky, A; Rivetti, A; Tosello, F; Vacchi, A

    2002-01-01

    We report results on drift velocity monitoring using MOS charge injectors in silicon drift detectors obtained in beam test conditions. The correction of velocity variations as small as 0.03% caused by temperature variations of the order of 0.04 K allowed to get an average space resolution along all the drift path of 28 mu m. Preliminary result demonstrating the possibility to correct for temperature gradients along the anode axis are also presented.

  18. Nuclear Counter Effect and Pion-Electron misidentification Simulations and 1998 test beam results

    CERN Document Server

    Dittmar, Michael

    1999-01-01

    The electron/charged pion discrimination within the ECAL is investigated using GEANT simulations and the 1998 test beam results. The Nuclear Counter Effect within the Avalanche Photo-Diodes enhances the probability of an electron misidentification. The test beam data show a Nuclear Counter Effect with a mean value of about 450 MeV for a Minimum Ionizing Particle crossing the APD, instead of the expected 200-250 MeV for a readout with a single APD. This value can be explained with the inefficient connection between crystals and APD`s in the PROTO 97 set-up. The pion beam data show a long tail in the E/p-ratio, which can be reproduced by GEANT simulations with Nuclear Counter Effect. GEANT simulations are then used for a study of the pion-electron confusion with the expected Nuclear Counter Effect and the foreseen set-up with two APD`s per crystal. These simulations show that the tail in the pion-energy deposition is still present. As a result one expects that about 0.1 % of the pions with 10 GeV < E &am...

  19. Compact Low-Voltage, High-Power, Multi-beam Klystron for ILC: Initial Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Teryaev, V. E. [Omega-P, New Haven; Shchelkunov, S. V. [Yale U.; Kazakov, S. Yu. [Fermilab; Hirshfield, J. L. [Yale U.; Ives, R. L. [Calabazas Creek Res. Inc., San Mateo; Marsden, D. [Calabazas Creek Res. Inc., San Mateo; Collins, G. [Calabazas Creek Res. Inc., San Mateo; Karimov, R. [Calabazas Creek Res. Inc., San Mateo; Jensen, R. [CPI, Palo Alto

    2015-10-20

    Initial test results of an L-band multi-beam klystron with parameters relevant for ILC are presented. The chief distinction of this tube from MBKs already developed for ILC is its low operating voltage of 60 kV, a virtue that implies considerable technological simplifications in the accelerator complex. To demonstrate the concept underlying the tubes design, a six-beamlet quadrant (a 54 inch high one-quarter portion of the full 1.3 GHz tube) was built and recently underwent initial tests, with main goals of demonstrating rated gun perveance, rated gain, and at least one-quarter of the full 10-MW rated power. Our initial three-day conditioning campaign without RF drive (140 microsec pulses @ 60 Hz) was stopped at 53% of full rated duty because of time-limits at the test-site; no signs appeared that would seem to prevent achieving full duty operation (i.e., 1.6 msec pulses @ 10 Hz). The subsequent tests with 10-15 microsec RF pulses confirmed the rated gain, produced output powers of up to 2.86 MW at 60 kV with high efficiency and 56 dB gain, and showed acceptable beam interception. These results suggest that a full version of the tube should be able to produce up to 11.5 MW. Follow-on tests are planned for later in 2015.

  20. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    Directory of Open Access Journals (Sweden)

    2010-04-01

    Full Text Available ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  1. Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes

    Energy Technology Data Exchange (ETDEWEB)

    Aidala, C.A.; et al.

    2017-04-05

    The sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is $2.8\\%\\oplus~15.5\\%/\\sqrt{E}$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $13.5\\%\\oplus 64.9\\%/\\sqrt{E}$. These results demonstrate that the performance of the proposed calorimeter system is consistent with \\geant simulations and satisfies the sPHENIX specifications.

  2. Beam test results for the SuperB-SVT thin striplet detector

    Science.gov (United States)

    Fabbri, L.; Comotti, D.; Manghisoni, M.; Re, V.; Traversi, G.; Gabrielli, A.; Giorgi, F.; Pellegrini, G.; Sbarra, C.; Semprini-Cesari, N.; Valentinetti, S.; Villa, M.; Zoccoli, A.; Berra, A.; Lietti, D.; Prest, M.; Bevan, A.; Wilson, F.; Beck, G.; Morris, J.; Ganaway, F.; Cenci, R.; Bombelli, L.; Citterio, M.; Coelli, S.; Fiorini, C.; Liberali, V.; Monti, M.; Nasri, B.; Neri, N.; Palombo, F.; Stabile, A.; Balestri, G.; Batignani, G.; Bernardelli, A.; Bettarini, S.; Bosi, F.; Casarosa, G.; Ceccanti, M.; Forti, F.; Giorgi, M. A.; Lusiani, A.; Mammini, P.; Morsani, F.; Oberhof, B.; Paoloni, E.; Perez, A.; Petragnani, G.; Profeti, A.; Rizzo, G.; Soldani, A.; Walsh, J.; Gaioni, L.; Manazza, A.; Quartieri, E.; Ratti, L.; Zucca, S.; Alampi, G.; Cotto, G.; Gamba, D.; Zambito, S.; Dalla Betta, G.-F.; Fontana, G.; Pancheri, L.; Povoli, M.; Verzellesi, G.; Bomben, M.; Bosisio, L.; Cristaudo, P.; Lanceri, L.; Liberti, B.; Rashevskaya, I.; Stella, C.; Vitale, L.

    2013-08-01

    The baseline detector option for the first layer of the SuperB Silicon Vertex Tracker (SVT) is a high resistivity double-sided silicon device with short strips (striplets) at 45° angle to the detector's edge. A prototype was tested with a 120 GeV/c pion beam in September 2011 at the SPS-H6 test-beam line at CERN. In this paper studies on efficiency, resolution and cluster size are reported.

  3. Test Beam results and integration of the ATLAS Level-1 Muon Barrel Trigger

    CERN Document Server

    Bianco, M; Cataldi, G; Chiodini, G; Fiore, G; Gorini, E; Grancagnolo, F; Miccoli, A; Perrino, R; Primavera, M; Spagnolo, S; Tassielli, G F; Ventura, A; Aloisio, A; Alviggi, M G; Canale, V; Caprio, M A; Carlino, G; Conventi, F; De Asmundis, R; Della Pietra, M; Della Volpe, D; Iengo, P; Izzo, V; Migliaccio, A; Patricelli, S; Sekhniaidze, G; Bocci, V; Chiodi, G; Gennari, E; Nisati, A; Pasqualucci, E; Pastore, F; Petrolo, E; Vari, R; Veneziano, Stefano; Aielli, G; Camarri, P; Cardarelli, R; Delle Fratte, C; Di Ciaccio, A; Di Simone, A; Di Stante, L; Liberti, B; Salamon, A; Santonico, R; Solfaroli, E; Aprodu, V; Petcu, M; 2004 IEEE Nuclear Science Symposium And Medical Imaging Conference

    2005-01-01

    The ATLAS Level-1 Muon Trigger will be crucial for the online selection of events with high transverse momentum muons and for its correct association to the bunch-crossing corresponding to the detected events. This system uses dedicated coarse granularity and fast detectors capable of providing measurements in two orthogonal projections. The Resistive Plate Chambers (RPCs) are used in the barrel region. The associated trigger electronics is based on a custom chip, the Coincidence Matrix, that performs space coincidences within programmable roads and time gates. The system is highly redundant and communicates with the ATLAS Level-1 trigger Processor with the MUCTPI Interface. The trigger electronics provides also the Readout of the RPCs. Preliminary results achieved with a full trigger tower with production detectors in the H8 test beam at CERN will be shown. In particular preliminary results on the integration of the barrel muon trigger electronics with the MUCTPI interface and with the ATLAS DAQ system will ...

  4. Results from the October 2014 CERN test beam of LumiCal

    CERN Document Server

    Borysov, O; Levy, A; Levy, I; Lukic, S; Moron, J; Neagu, A T; Preda, T; Rosenblat, O

    2016-01-01

    A prototype of a luminometer, designed for a future e+e- collider detector, was tested in the CERN PS accelerator T9 testbeam. The objective of this test beam was to demonstrate a multi-plane operation, to study the development of the electromagnetic shower and to compare it with MC simulations.

  5. Laboratory and test beam results from a large-area silicon drift detector

    CERN Document Server

    Bonvicini, V; Giubellino, P; Gregorio, A; Idzik, M; Kolojvari, A A; Montaño-Zetina, L M; Nouais, D; Petta, C; Rashevsky, A; Randazzo, N; Reito, S; Tosello, F; Vacchi, A; Vinogradov, L I; Zampa, N

    2000-01-01

    A very large-area (6.75*8 cm/sup 2/) silicon drift detector with integrated high-voltage divider has been designed, produced and fully characterised in the laboratory by means of ad hoc designed MOS injection electrodes. The detector is of the "butterfly" type, the sensitive area being subdivided into two regions with a maximum drift length of 3.3 cm. The device was also tested in a pion beam (at the CERN PS) tagged by means of a microstrip detector telescope. Bipolar VLSI front-end cells featuring a noise of 250 e/sup -/ RMS at 0 pF with a slope of 40 e/sup -//pF have been used to read out the signals. The detector showed an excellent stability and featured the expected characteristics. Some preliminary results will be presented. (12 refs).

  6. Low-energy beam test results of a calorimeter prototype for the CREAM experiment

    CERN Document Server

    Bagliesi, M G; Ganel, O; Kim, K C; Lee, M H; Lomtadze, T A; Lutz, L; Maestro, P; Marrocchesi, P S; Meucci, M; Millucci, V; Morsani, F; Seo, E S; Valle, G D

    2003-01-01

    CREAM (Cosmic Ray Energetics and Mass) is an experiment under construction for a direct measurement of high energy cosmic rays (10 /sup 12/ to >5.10/sup 14/ eV) over the elemental range from proton to iron. The first flight of CREAM is intended to demonstrate the new ultra long duration balloon (ULDB) capability under development by NASA. A prototype of a tungsten-SciFi imaging calorimeter designed for CREAM has been tested at CERN with electron beam energies ranging from 5 to 100 GeV. Although the calorimeter module is optimized for cosmic-ray spectral measurements in the multiTeV region, the response of its electromagnetic section to low energy electrons has been studied with this dedicated prototype. Results show good agreement with the expected behaviour in terms of linearity and energy resolution.

  7. Test beam results of a depleted monolithic active pixel sensor (DMAPS) prototype

    Energy Technology Data Exchange (ETDEWEB)

    Obermann, Theresa; Hemperek, Tomasz; Huegging, Fabian; Krueger, Hans; Wermes, Norbert [Bonn Univ. (Germany); Schwenker, Benjamin [Goettingen Univ. (Germany); Collaboration: ATLAS Pixel-Collaboration

    2016-07-01

    New monolithic detector concepts are currently being explored for future particle physics experiments, in particular for the upgrade of the ATLAS detector. Common to monolithic pixel detectors is the integration of the front-end circuitry and the sensor on the same silicon substrate. The DMAPS concept makes use of high resistive silicon as substrate. It enables the application of a high bias voltage to create a drift field for the charge collection in the sensor part as well as the full usage of CMOS logic in the same piece of silicon. DMAPS prototypes from several foundries are available since three years and have been extensively characterized in the lab. In this talk, results of test beam campaigns, with neutron irradiated prototypes implemented in the ESPROS process, are presented.

  8. TCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectors

    Energy Technology Data Exchange (ETDEWEB)

    Luukka, P.; Harkonen, J.; Maenpaa, T.; /Helsinki Inst. of Phys.; Betchart, B.; /Rochester U.; Czellar, S.; /Helsinki Inst. of Phys.; Demina, R.; /Rochester U.; Furgeri, A.; /Karlsruhe U., EKP; Gotra, Y.; /Rochester U.; Frey, M.; Hartmann, F.; /Karlsruhe U., EKP; Korjenevski, S.; /Rochester U. /Helsinki Inst. of Phys. /Karlsruhe U., EKP /Louvain U. /Karlsruhe U., EKP

    2009-01-01

    Pad and strip detectors processed on high resistivity n-type magnetic Czochralski silicon (MCz-Si) were irradiated to several different fluences with protons. The pad detectors were characterized with the transient current technique (TCT) and the full-size strip detectors with a reference beam telescope and a 225 GeV muon beam. The TCT measurements indicate a double junction structure and space charge sign inversion in MCz-Si detectors after 6x1014 1 MeV neq/cm2 fluence. In the beam test a signal-to-noise (S/N) ratio of 50 was measured for a non-irradiated MCz-Si sensor, and a S/N ratio of 20 for the sensors irradiated to the fluences of 1x1014 1 and 5x1014 1 MeV neq/cm2.

  9. Test-beam results from the ATLAS level-1 calorimeter trigger demonstrator

    CERN Document Server

    Bohm, C; Bright-Thomas, P G; Connors, A; Edwards, J; Eisenhandler, Eric F; Ellis, Nick; Engström, M; Farthouat, Philippe; Garvey, J; Gee, C N P; Gillman, A R; Hanke, P; Hatley, R; Hellman, S; Hillier, S J; Kluge, E E; Landon, M; Maddox, A J; Pentney, J M; Perera, V J O; Pfeiffer, U; Schuler, G A; Schumacher, C; Shah, T P; Silverstein, S; Staley, R J; Watkins, P M; Watson, A T; Wunsch, M

    1998-01-01

    The ATLAS level-1 calorimeter trigger will utilise a number of advanced technologies, many of which have already been successfully demonstrated. To evaluate the different technologies associated with the important areas of $9 high-speed data transport a large demonstrator system has been designed and operated during the last two years, using signals from prototype calorimeters in the ATLAS test-beam. Using this system, inter-crate data transmission and $9 reception have been demonstrated at over 1.4 Gbyte/s, with individual links running at up to 1.6 Gbaud. Operating with 160 Mbit/s signals across a transmission-line backplane, custom transceiver ASICs have achieved inter-module data $9 fanout at peak rates above 800 Mbyte/s. With the addition of further modules, the system was extended to emulate a vertical slice through the ATLAS level-1 calorimeter trigger. We present here the results from these tests, including $9 measurements of bit-error rates across different data paths. (12 refs).

  10. 3D-FBK Pixel sensors: recent beam tests results with irradiated devices

    CERN Document Server

    Micelli, A; Sandaker, H; Stugu, B; Barbero, M; Hugging, F; Karagounis, M; Kostyukhin, V; Kruger, H; Tsung, J W; Wermes, N; Capua, M; Fazio, S; Mastroberardino, A; Susinno, G; Gallrapp, C; Di Girolamo, B; Dobos, D; La Rosa, A; Pernegger, H; Roe, S; Slavicek, T; Pospisil, S; Jakobs, K; Kohler, M; Parzefall, U; Darbo, G; Gariano, G; Gemme, C; Rovani, A; Ruscino, E; Butter, C; Bates, R; Oshea, V; Parker, S; Cavalli-Sforza, M; Grinstein, S; Korokolov, I; Pradilla, C; Einsweiler, K; Garcia-Sciveres, M; Borri, M; Da Via, C; Freestone, J; Kolya, S; Lai, C H; Nellist, C; Pater, J; Thompson, R; Watts, S J; Hoeferkamp, M; Seidel, S; Bolle, E; Gjersdal, H; Sjobaek, K N; Stapnes, S; Rohne, O; Su, D; Young, C; Hansson, P; Grenier, P; Hasi, J; Kenney, C; Kocian, M; Jackson, P; Silverstein, D; Davetak, H; DeWilde, B; Tsybychev, D; Dalla Betta, G F; Gabos, P; Povoli, M; Cobal, M; Giordani, M P; Selmi, L; Cristofoli, A; Esseni, D; Palestri, P; Fleta, C; Lozano, M; Pellegrini, G; Boscardin, M; Bagolini, A; Piemonte, C; Ronchin, S; Zorzi, N; Hansen, T E; Hansen, T; Kok, A; Lietaer, N; Kalliopuska, J; Oja, A

    2011-01-01

    The Pixel detector is the innermost part of the ATLAS experiment tracking device at the Large Hadron Collider (LHC), and plays a key role in the reconstruction of the primary and secondary vertices of short-lived particles. To cope with the high level of radiation produced during the collider operation, it is planned to add to the present three layers of silicon pixel sensors which constitute the Pixel Detector, an additional layer (Insertable B-Layer, or IBL) of sensors. 3D silicon sensors are one of the technologies which are under study for the IBL. 3D silicon technology is an innovative combination of very-large-scale integration (VLSI) and Micro-Electro-Mechanical-Systems (MEMS) where electrodes are fabricated inside the silicon bulk instead of being implanted on the wafer surfaces. 3D sensors, with electrodes fully or partially penetrating the silicon substrate, are currently fabricated at different processing facilities in Europe and USA. This paper reports on the 2010 June beam test results for irradi...

  11. Beam test results for the upgraded LHCb RICH opto-electronic readout system

    CERN Multimedia

    Carniti, Paolo

    2016-01-01

    The LHCb experiment is devoted to high-precision measurements of CP violation and search for New Physics by studying the decays of beauty and charmed hadrons produced at the Large Hadron Collider (LHC). Two RICH detectors are currently installed and operating successfully, providing a crucial role in the particle identification system of the LHCb experiment. Starting from 2019, the LHCb experiment will be upgraded to operate at higher luminosity, extending its potential for discovery and study of new phenomena. Both the RICH detectors will be upgraded and the entire opto-electronic system has been redesigned in order to cope with the new specifications, namely higher readout rates, and increased occupancies. The new photodetectors, readout electronics, mechanical assembly and cooling system have reached the final phase of development and their performance was thoroughly and successfully validated during several beam test sessions in 2014 and 2015 at the SPS facility at CERN. Details of the test setup and perf...

  12. Test-beam Results from a RICH Detector Prototype Using Aerogel Radiator and Pixel Hybrid Photon Detectors

    CERN Document Server

    Aglieri-Rinella, G; Van Lysebetten, A; Piedigrossi, D; Wyllie, K; Bellunato, T F; Calvi, M; Matteuzzi, C; Musy, M; Perego, D L; Somerville, L P; Newby, C; Easo, S; Wotton, S

    2006-01-01

    A test-beam study was performed at CERN with a Ring Imaging Cherenkov (RICH) prototype using three pixel Hybrid Photon Detectors. Results on the photon yield and Cherenkov angle resolution are presented here, for the Aerogel radiator and also for reference runs taken with Nitrogen radiator.

  13. Final focus test beam

    Energy Technology Data Exchange (ETDEWEB)

    1991-03-01

    This report discusses the following: the Final Focus Test Beam Project; optical design; magnets; instrumentation; magnetic measurement and BPM calibration; mechanical alignment and stabilization; vacuum system; power supplies; control system; radiation shielding and personnel protection; infrastructure; and administration.

  14. Beam test results of a 16 ps timing system based on ultra-fast silicon detectors

    Science.gov (United States)

    Cartiglia, N.; Staiano, A.; Sola, V.; Arcidiacono, R.; Cirio, R.; Cenna, F.; Ferrero, M.; Monaco, V.; Mulargia, R.; Obertino, M.; Ravera, F.; Sacchi, R.; Bellora, A.; Durando, S.; Mandurrino, M.; Minafra, N.; Fadeyev, V.; Freeman, P.; Galloway, Z.; Gkougkousis, E.; Grabas, H.; Gruey, B.; Labitan, C. A.; Losakul, R.; Luce, Z.; McKinney-Martinez, F.; Sadrozinski, H. F.-W.; Seiden, A.; Spencer, E.; Wilder, M.; Woods, N.; Zatserklyaniy, A.; Pellegrini, G.; Hidalgo, S.; Carulla, M.; Flores, D.; Merlos, A.; Quirion, D.; Cindro, V.; Kramberger, G.; Mandić, I.; Mikuž, M.; Zavrtanik, M.

    2017-04-01

    In this paper we report on the timing resolution obtained in a beam test with pions of 180 GeV/c momentum at CERN for the first production of 45 μm thick Ultra-Fast Silicon Detectors (UFSD). UFSD are based on the Low-Gain Avalanche Detector (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test had a pad area of 1.7 mm2. The gain was measured to vary between 5 and 70 depending on the sensor bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution was determined by doing Gaussian fits to the time-of-flight of the particles between one or more UFSD and the trigger counter. For a single UFSD the resolution was measured to be 34 ps for a bias voltage of 200 V, and 27 ps for a bias voltage of 230 V. For the combination of 3 UFSD the timing resolution was 20 ps for a bias voltage of 200 V, and 16 ps for a bias voltage of 230 V.

  15. Beam test results of a 16 ps timing system based on ultra-fast silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Cartiglia, N., E-mail: cartiglia@to.infn.it [INFN, Torino (Italy); Staiano, A.; Sola, V. [INFN, Torino (Italy); Arcidiacono, R. [INFN, Torino (Italy); Università del Piemonte Orientale (Italy); Cirio, R.; Cenna, F.; Ferrero, M.; Monaco, V.; Mulargia, R.; Obertino, M.; Ravera, F.; Sacchi, R. [INFN, Torino (Italy); Università di Torino, Torino (Italy); Bellora, A.; Durando, S. [Università di Torino, Torino (Italy); Mandurrino, M. [Politecnico di Torino, Torino (Italy); Minafra, N. [University of Kansas, KS (United States); Fadeyev, V.; Freeman, P.; Galloway, Z.; Gkougkousis, E. [SCIPP, University of California Santa Cruz, CA 95064 (United States); and others

    2017-04-01

    In this paper we report on the timing resolution obtained in a beam test with pions of 180 GeV/c momentum at CERN for the first production of 45 µm thick Ultra-Fast Silicon Detectors (UFSD). UFSD are based on the Low-Gain Avalanche Detector (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test had a pad area of 1.7 mm{sup 2}. The gain was measured to vary between 5 and 70 depending on the sensor bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution was determined by doing Gaussian fits to the time-of-flight of the particles between one or more UFSD and the trigger counter. For a single UFSD the resolution was measured to be 34 ps for a bias voltage of 200 V, and 27 ps for a bias voltage of 230 V. For the combination of 3 UFSD the timing resolution was 20 ps for a bias voltage of 200 V, and 16 ps for a bias voltage of 230 V.

  16. Test beam results using scintillating fibers read out by a multianode phototube and visible light photon counters

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, B.; Davies, R.; Koltick, D.; McIlwain, R.; Schmitz, C.J.; Shibata, E.I. (Purdue Univ., Physics Dept., West Lafayette, IN (United States)); Atac, M. (Univ. California, Dept. of Physics, Los Angeles, CA (United States) Fermilab, Batavia, IL (United States)); Baumbaugh, B.; Jaques, J.; Kehoe, R.; Marchant, J.; Ruchti, R.; Warchol, J.; Wayne, M. (Univ. Notre Dame, Dept. of Physics, IN (United States)); Binkley, M.; Elias, J. (Fermilab, Batavia, IL (United States)); Goldberg, H.; Margulies, S.; Solomon, J. (Univ. Illinois, Dept. of Physics, Coll. of Liberal Arts and Sciences, Chicago, IL (United States)); Armstrong, T.; Lewis, R.; Smith, G. (Pennsylvania State Univ., University Park, PA (United States))

    1993-04-01

    The results from a test beam experiment at Fermilab using 830 [mu]m scintillating fibers, a version of a solid state photomultiplier, the VLPC, and a 256 channel multianode phototube are reported. Muon tracks were observed in a combined tracking system read out by VLPCs and the multianode phototube. A tracking algorithm was developed to unfold the complex cross talk pattern observed in the multianode phototube. A spatial resolution of [proportional to]130 [mu]m was obtained. (orig.).

  17. GTK beam test 2017

    CERN Document Server

    Vostinic, Snezana

    2017-01-01

    The GTK is in operation at NA62 since 2014 and is among the few silicon pixel detectors performing 4D tracking. This summer, a beam test was conducted to study the phenomena determining the detector time resolution. The project described here contributed to the beam test preparation, data taking and data analyses. One of the main goals of the test was to understand the weight field contribution to the detector time resolution. This field is distorting the signal pulse shape at the edge of the pixel. Hence, to study this effect, the position of the hits inside the pixel has to be determined. An external telescope was therefore used for this purpose.

  18. First Beam and High-Gradient Cryomodule Commissioning Results of the Advanced Superconducting Test Accelerator at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, Darren; et al.

    2015-06-01

    The advanced superconducting test accelerator at Fermilab has accelerated electrons to 20 MeV and, separately, the International Linear Collider (ILC) style 8-cavity cryomodule has achieved the ILC performance milestone of 31.5 MV/m per cavity. When fully completed, the accelerator will consist of a photoinjector, one ILC-type cryomodule, multiple accelerator R&D beamlines, and a downstream beamline to inject 300 MeV electrons into the Integrable Optics Test Accelerator (IOTA). We report on the results of first beam, the achievement of our cryomodule to ILC gradient specifications, and near-term future plans for the facility.

  19. Beam Test Results for Single- and Double-Sided Silicon Detector Prototypes of the CMS Central Detector

    CERN Document Server

    Adriani, O

    1997-01-01

    We report the results of two beam tests performed in July and September 1995 at CERN using silicon microstrip detectors of various types: single sided, double sided with small angle stereo strips, double sided with orthogonal strips, double sided with pads. For the read-out electronics use was made of Preshape32, Premux128 and VA1 chips. The signal to noise ratio and the resolution of the detectors was studied for different incident angles of the incoming particles and for different values of the detector bias voltage. The goal of these tests was to check and improve the performances of the prototypes for the CMS Central Detector.

  20. Test Beam Coordination: 2003 ATLAS Combined Test Beam

    CERN Multimedia

    Di Girolamo, B.

    The 2003 Test Beam Period The 2003 Test Beam period has been very fruitful for ATLAS. In spite of several days lost because of the accelerator problems, ATLAS has been able to achieve many results: FCAL has completed the calibration program in H6 Tilecal has completed the calibration program in H8 Pixel has performed extensive studies with normal and high intensity beams (up to 1.4*108 hadrons/spill) SCT has completed a variety of studies with quite a high number of modules operated concurrently TRT has performed several studies at high, low and very low energy (first use of the new H8 beam in the range 1 to 9 GeV) Muons (MDT,RPC and TGC) have been operating a large setup for about 5 months. The almost final MDT ROD (MROD) has been integrated in the readout and the final trigger electronics for TGC and RPC has been tested and certified with normal beam and during dedicated 40 MHz beam periods. The TDAQ has exploited a new generation prototype successfully and the new Event Filter infrastructure f...

  1. Wideband precision two-axis beam steerer tracking servo design and test results

    Science.gov (United States)

    Hayden, William L.; McCullough, T.; Reth, A.; Kaufman, David M.

    1993-08-01

    A compact, light-weight, two-axis beam steerer (TABS) with a 38 mm (1.5') Beryllium clear aperture was designed into a 1000 Hz servo loop for precision tracking of a remote laser source. The design is composed of a quadrant photodiode, a track-tone demodulator, a linear ratiometric processor with sum and difference circuits, and a proportional/integral controller with a phase lead compensator. The demodulator is a phase-lock-loop used for locking onto and then synchronously detecting the envelope of a modulated tracking beacon. This approach provides background rejection, star discrimination (or any other CW source), receiver AC coupling, and 1/f noise reduction. The linear ratiometric processor provides x and y error signals to the controller which are independent of input signal levels. The far-field performance goal is < 0.5 microradians rms from a Landsat-type of base motion disturbance.

  2. Beam test results of pixel triggerless prototypes for the P{sup ¯}ANDA MVD

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, Daniela, E-mail: calvo@to.infn.it [INFN–Sezione di Torino, Torino (Italy); De Remigis, Paolo; Filippi, Alessandra; Mazza, Giovanni; Rivetti, Angelo; Wheadon, Richard [INFN–Sezione di Torino, Torino (Italy); De Mori, Francesca; Marcello, Simonetta; Zotti, Laura [INFN–Sezione di Torino, Torino (Italy); Universita' di Fisica, Torino (Italy); Bianco, Simone; Zaunick, Hans-Georg [HISKP, Universität Bonn (Germany); Brinkmann, Kai-Thomas; Quagli, Tommaso; Schnell, Robert [II. Physikalisches Institut, Justus–Liebig Universität Giessen, Giessen (Germany)

    2013-12-21

    Hybrid pixel and double sided silicon microstrip devices will equip the Micro Vertex Detector of the P{sup ¯}ANDA experiment. The most challenging request of the experiment is the continuous readout at the rate of 2×10{sup 7} interactions/s. The detector is in an advanced R and D phase and pixel assemblies, composed of thinned epitaxial sensor read out by the custom chip prototype ToPix, developed in the 130 nm CMOS technology, were produced. The triggerless ASIC implements readout channels that are able to detect signals and transmit the information with a precise timestamp. It performs the energy loss measurement using the Time over Threshold technique, in the input range to about 50 fC. A dedicated testing bench allows the control and the readout of each single chip assembly. Two experimental setups were assembled for testing these first single chip prototypes with pions at CERN, T9, in August 2012. The first one is based on a pixel assembly positioned in the middle of a telescope composed of double sided silicon strips sensors. A 50 MHz clock signal synchronizes these two systems, the triggerless pixels and the strip detectors triggered by scintillation detectors. The second experimental setup is a tracking station housing four pixel assemblies. First results will be reported. -- Highlights: •The most challenge request of the experiment is the continuous readout. •The triggerless circuit transmits the information with a precise timestamp. •The sensor is based on a epitaxial silicon layer. •Timestamp matching of the detected hits belonging to the same event.

  3. Test beam results of a stereo preshower integrated in the liquid argon accordion calorimeter

    CERN Document Server

    Davis, R; Greenious, G; Kitching, P; Olsen, B; Pinfold, James L; Rodning, N L; Boos, E; Zhautykov, B O; Aubert, Bernard; Bazan, A; Beaugiraud, B; Boniface, J; Colas, Jacques; Eynard, G; Jézéquel, S; Le Flour, T; Linossier, O; Nicoleau, S; Sauvage, G; Thion, J; Van den Plas, D; Wingerter-Seez, I; Zitoun, R; Zolnierowski, Y; Chmeissani, M; Fernández, E; Garrido, L; Martínez, M; Padilla, C; Citterio, M; Gordon, H A; Lissauer, D; Ma, H; Makowiecki, D S; Radeka, V; Rahm, David Charles; Rescia, S; Stephani, D; Takai, H; Baisin, L; Berset, J C; Chevalley, J L; Gianotti, F; Gildemeister, O; Marin, C P; Nessi, Marzio; Poggioli, Luc; Richter, W; Vuillemin, V; Baze, J M; Delagnes, E; Gosset, L G; Lavocat, P; Lottin, J P; Mansoulié, B; Meyer, J P; Renardy, J F; Schwindling, J; Simion, S; Taguet, J P; Teiger, J; Walter, C; Collot, J; de Saintignon, P; Hostachy, J Y; Mahout, G; Barreiro, F; Del Peso, J; García, J; Hervás, L; Labarga, L; Romero, P; Scheel, C V; Chekhtman, A; Cousinou, M C; Dargent, P; Dinkespiler, B; Etienne, F; Fassnacht, P; Fouchez, D; Martin, L; Miotto, A; Monnier, E; Nagy, E; Olivetto, C; Tisserant, S; Battistoni, G; Camin, D V; Cavalli, D; Costa, G; Cozzi, L; Fedyakin, N N; Ferrari, A; Mandelli, L; Mazzanti, M; Perini, L; Resconi, S; Sala, P R; Beaudoin, G; Depommier, P; León-Florián, E; Leroy, C; Roy, P; Augé, E; Breton, D; Chase, Robert L; Chollet, J C; de La Taille, C; Fayard, Louis; Fournier, D; González, J; Hrisoho, A T; Jacquier, Y; Merkel, B; Nikolic, I A; Noppe, J M; Parrour, G; Pétroff, P; Puzo, P; Richer, J P; Schaffer, A C; Seguin-Moreau, N; Serin, L; Tisserand, V; Veillet, J J; Vichou, I; Canton, B; David, J; Genat, J F; Imbault, D; Le Dortz, O; Savoy-Navarro, Aurore; Schwemling, P; Eek, L O; Lund-Jensen, B; Söderqvist, J; Astbury, Alan; Keeler, Richard K; Lefebvre, M; Robertson, S; White, J

    1998-01-01

    This paper describes the construction of an integrated preshower within the RD3 liquid argon accordion calorimeter. It has a stereo view which enables the measurement of two transverse coordinates. The prototype was tested at CERN with electrons, photons and muons to validate its capability to work at LHC ( Energy resolution, impact point resolution, angular resolution, $\\pi^o$/$\\gamma$ rejection ).

  4. Testing of full-size reinforced concrete beams strengthened with FRP composites : experimental results and design methods verification

    Science.gov (United States)

    2000-06-01

    In 1997, a load rating of an historic reinforced concrete bridge in Oregon, Horsetail Creek Bridge, indicated substandard shear and moment capacities of the beams. As a result, the Bridge was strengthened with fiber reinforced : polymer composites as...

  5. Testing of full-size reinforced concrete beams strengthened with FRP composites : experimental results and design methods verification(appendices)

    Science.gov (United States)

    2000-06-01

    In 1997, a load rating of an historic reinforced concrete bridge in Oregon, Horsetail Creek Bridge, indicated substandard shear and moment capacities of the beams. As a result, the Bridge was strengthened with fiber reinforced polymer composites as a...

  6. Beam test results of CMS RPCs at high eta region under high-radiation environment

    CERN Document Server

    Park, S; Bahk, S Y; Hong, B; Hong, S J; Kang, D H; Kang, T I; Kim, T J; Kim, Y J; Kim, Y U; Koo, D G; Lee, H W; Lee, K S; Lee, S J; Lim, J K; Moon, D H; Nam, S K; Oh, J K; Park, W J; Rhee, J T; Ryu, M S; Shim, H H; Sim, K S

    2004-01-01

    The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1 kHz/cm**2. It is still unknown if the RPCs coated with linseed oil can be operated under such a high- radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite is chemically stabler than linseed oil. We have constructed oiled and non-oiled RPCs at the high eta region of CMS using phenolic bakelite and tested them in the Gamma Irradiation Facility at CERN. While both RPCs show the same characteristics in the efficiency and the strip multiplicity, the non-oiled RPC generates an intrinsic noise rate of 50 Hz/cm**2, compared to only 5 Hz/cm**2 for the oiled RPC, both at 10.0kV which is about 100 V above the 95% knee of the efficiency curve.

  7. First Results from Beam Measurements at the 3 MeV Test Stand for CERN LINAC4

    CERN Document Server

    Cheymol, B; Lokhovitsky, A; Midttun, O; Raich, U; Roncarolo, F; Scrivens, R; Zorin, E

    2011-01-01

    The H- source and the low energy beam transport(LEBT) line will determine to a large extend the performance of Linac-4, the new machine foreseen at CERN as injector into the PS Booster. For this reason a test stand is being set up, consisting of the source, the LEBT, the RFQ and the chopper line. Up to now only the source and LEBT are installed. First measurements have been performed using a Faraday Cup to measure the total source intensity, a slit and grid emittance meter for transverse emittance measurements as well as a spectrometer for energy spread measurements. Beam intensity, profile, transverse emittance and energy spread have been measured. The paper discusses measurements done on H- beams at 35 kV extraction voltage as well as proton beams at 45 keV.

  8. Test-beam activities and results for the ATLAS ITk pixel detector

    CERN Document Server

    Bisanz, Tobias; The ATLAS collaboration

    2017-01-01

    The Phase-II upgrade of the LHC will result in an increase of the instantaneous luminosity up to about $5\\times10^{34}~\\text{cm}^{-2}\\text{s}^{-1}$. To cope with the resulting challenges the current Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) system. The Pixel Detector will have to deal with occupancies of about 300~hits/FE/s as well as a fluence of $2\\times10^{16}~\\text{n}_\\text{eq}\\text{cm}^{-2}$. Various sensor layouts are under development, aiming at providing a high performance, cost effective pixel instrumentation to cover an active area of about $10~\\text{m}^2$. These range from thin planar silicon, over 3D silicon, to active CMOS sensors.\\par After extensive characterization of the sensors in the lab, their charge collection properties and hit efficiency are measured in common testbeam campaigns, which provide valuable feedback for improvements of the layout. Testbeam measurements of the final prototypes will be used for the decision of which sensor types will be installed in...

  9. Test-beam activities and results for the ATLAS ITk pixel detector

    Science.gov (United States)

    Bisanz, T.

    2017-12-01

    The Phase-II upgrade of the LHC aims at an increase of the instantaneous luminosity up to about 5×1034 cm‑2 s‑1. To cope with the resulting challenges the current Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) system. The Pixel Detector will have to deal with occupancies of about 300 hits/FE/s as well as a fluence of around 2×1016 neq cm‑2. Various sensor layouts are under development, aiming at providing a high performance, cost effective pixel instrumentation to cover an active area of about 10 m2. These range from thin planar silicon, 3D silicon, to active CMOS sensors. After extensive characterization of the sensors in the lab, their charge collection properties and hit efficiency are measured in common testbeam campaigns, which provide valuable feedback for improvements of the layout. Testbeam measurements of the final prototypes will be used for the decision of which sensor types will be installed in ITk. The setups used in the ITk Pixel testbeam campaigns will be presented, including the common track reconstruction and analysis software. Results from the latest measurements will be shown, highlighting some of the developments and challenges for the ITk Pixel sensors.

  10. Test-beam activities and results for the ATLAS ITk pixel detector

    CERN Document Server

    Bisanz, Tobias; The ATLAS collaboration

    2017-01-01

    The Phase-II upgrade of the LHC will result in an increase of the instantaneous luminosity up to about 5×1034 cm−2s−1. To cope with the challenges the current Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) system. The Pixel Detector will have to deal with occupancies of about 300~hits/FE/s as well as a fluence of 2×1016neqcm−2. Various sensor layouts are under development, aiming at providing a high performance, cost effective pixel instrumentation to cover an active area of about 10~m2. These range from thin planar silicon, over 3D silicon, to active CMOS sensors. After extensive characterization of the sensors in the lab, their charge collection properties and hit efficiency are measured in common testbeam campaigns, which provide valuable feedback for improvements of the layout. Testbeam measurements of the final prototypes will be used for the decision of which sensor types will be installed in ITk. The setups used in the ITk Pixel testbeam campaigns will be presented, inclu...

  11. The CALICE Tile Hadron Calorimeter Prototype With SiPM Readout: Design, Construction and First Test Beam Results

    CERN Document Server

    Wattimena, N

    2008-01-01

    The CALICE collaboration has constructed a test beam hadronic calorimeter (HCAL) with 7608 scintillator tiles, individually read out by novel multi-pixel Geiger mode photodiodes, so called SiPMs, and tested it in electron and hadron beams at CERN. This prototype is the first device which uses SiPMs on a large scale; its purpose is to establish the technology and to record hadron shower data with unprecedented granularity for the validation of simulation models and the development of clustering algorithms.

  12. Beam Test Results of Thin n-in-p 3D and Planar Pixel Sensors for the High Luminosity LHC Tracker Upgrade at CMS

    CERN Document Server

    Zoi, Irene; Dalla Betta, G. F; Dinardo, Mauro; Giacomini, G; Menasce, Dario; Mendicino, R; Meschini, Marco; Messineo, Alberto; Moroni, Luigi; Ronchin, S; Sultan, D.M.S; Uplegger, Lorenzo; Vernieri, Caterina; Viliani, Lorenzo; Zuolo, Davide

    2017-01-01

    This is necessary for the pixel tracker that is the closest to the interaction point and will be replaced. In this paper, the results, from beam tests performed at Fermilab Test Beam Facility, of thin (100 $\\mu$m and 130 $\\mu$m thick) n-in-p type sensors, assembled into hybrid single chip modules bump bonded to the PSI46dig readou...

  13. Assessment of Corona/Arcing Hazard for Electron Beam Welding in Space Shuttle Bay at LEO for ISWE: Test Results

    Science.gov (United States)

    Nunes, A. C., Jr.; Russell, C.; Vaughn, J.; Stocks, C.; ODell, D.; Bhat, B.

    1996-01-01

    Test welds were made in argon over a range of pressures from 10-5 to 10-3 torr (the latter pressure an order of magnitude above pressures anticipated in the space shuttle bay during welding) with and without plasma on 304 stainless steel, 6Al-4V titanium, and 5456 aluminum in search of any possible unwanted electrical discharges. Only a faint steady glow of beam-excited atoms around the electron beam and sometimes extending out into the vacuum chamber was observed. No signs of current spiking or of any potentially dangerous electrical discharge were found.

  14. Heavy ion beam test results of the silicon charge detector for the CREAM cosmic ray balloon mission

    CERN Document Server

    Park, I H; Bok, J B; Ganel, O; Hahn, J H; Han, W; Hyun, H J; Kim, H J; Kim, M Y; Kim, Y J; Lee, J K; Lutz, L; Malinine, A; Min, K W; Nam, S W; Nam, W; Park, H; Park, N H; Seo, E S; Seon, K I; Sone, J H; Yang, J; Zinn, S Y

    2004-01-01

    The Cosmic Ray Energetics And Mass (CREAM) experiment is designed to measure cosmic ray elemental spectra to help understand the source and acceleration mechanisms of ultra-high-energy cosmic rays. The payload is planned to launch in December 2004 from McMurdo Station, Antarctica as a balloon mission. A Silicon Charge Detector (SCD) was designed and constructed for the CREAM experiment to provide precision charge measurements of incident cosmic rays with a resolution of 0.2 charge unit or better. The SCD was exposed to heavy ion beams at CERN's H2 beam line in November 2003. The results reported here show the SCD performs as designed.

  15. Beam-Based Alignment in CTF3 Test Beam Line

    OpenAIRE

    Sterbini, G; Dӧbert, S; Marín, E.; Lillestol, RL; Schulte, D.; Adli, E.

    2012-01-01

    The CLIC linear collider is based on the two beams acceleration scheme. During acceleration of the colliding beams, the drive beam suffers a large build up on its energy spread. In order to efficiently transport such a beam, beam-based alignment techniques together with tight prealignment tolerances are crucial. To evaluate the performance of these steering algorithms, a beam-based steering campaign has been conducted at the Test Beam Line of the CLIC Test Facility. In the following we presen...

  16. Beam test results of STS prototype modules for the future accelerator experiments FAIR/CBM and NICA/MPD projects

    Science.gov (United States)

    Kharlamov, Petr; Dementev, Dmitrii; Shitenkov, Mikhail

    2017-10-01

    High-energy heavy-ion collision experiments provide the unique possibility to create and investigate extreme states of strongly-interacted matter and address the fundamental aspects of QCD. The experimental investigation the QCD phase diagram would be a major breakthrough in our understanding of the properties of nuclear matter. The reconstruction of the charged particles created in the nuclear collisions, including the determination of their momenta, is the central detection task in high-energy heavy-ion experiments. It is taken up by the Silicon Tracking System in CBM@FAIR and by Inner Tracker in MPD@NICA currently under development. These experiments requires very fast and radiation hard detectors, a novel data read-out and analysis concept including free streaming front-end electronics. Thermal and beam tests of prototype detector modules for these tracking systems showed the stability of sensors and readout electronics operation.

  17. Beam test results of STS prototype modules for the future accelerator experiments FAIR/CBM and NICA/MPD projects

    Directory of Open Access Journals (Sweden)

    Kharlamov Petr

    2017-01-01

    Full Text Available High-energy heavy-ion collision experiments provide the unique possibility to create and investigate extreme states of strongly-interacted matter and address the fundamental aspects of QCD. The experimental investigation the QCD phase diagram would be a major breakthrough in our understanding of the properties of nuclear matter. The reconstruction of the charged particles created in the nuclear collisions, including the determination of their momenta, is the central detection task in high-energy heavy-ion experiments. It is taken up by the Silicon Tracking System in CBM@FAIR and by Inner Tracker in MPD@NICA currently under development. These experiments requires very fast and radiation hard detectors, a novel data read-out and analysis concept including free streaming front-end electronics. Thermal and beam tests of prototype detector modules for these tracking systems showed the stability of sensors and readout electronics operation.

  18. Test results for electron beam charging of flexible insulators and composites. [solar array substrates, honeycomb panels, and thin dielectric films

    Science.gov (United States)

    Staskus, J. V.; Berkopec, F. D.

    1979-01-01

    Flexible solar-array substrates, graphite-fiber/epoxy - aluminum honeycomb panels, and thin dielectric films were exposed to monoenergetic electron beams ranging in energy from 2 to 20 keV in the Lewis Research Center's geomagnetic-substorm-environment simulation facility to determine surface potentials, dc currents, and surface discharges. The four solar-array substrate samples consisted of Kapton sheet reinforced with fabrics of woven glass or carbon fibers. They represented different construction techniques that might be used to reduce the charge accumulation on the array back surface. Five honeycomb-panel samples were tested, two of which were representative of Voyager antenna materials and had either conductive or nonconductive painted surfaces. A third sample was of Navstar solar-array substrate material. The other two samples were of materials proposed for use on Intelsat V. All the honeycomb-panel samples had graphite-fiber/epoxy composite face sheets. The thin dielectric films were 2.54-micrometer-thick Mylar and 7.62-micrometer-thick Kapton.

  19. Beam Instrumentation for the Single Electron DAFNE Beam Test Facility

    CERN Document Server

    Mazzitelli, G; Valente, P; Vescovi, M

    2003-01-01

    The DAΦNE Beam Test Facility (BTF) has been successfully commissioned in February 2002, and started operation in November of the same year. Although the BTF is a beam transfer line optimized for single particle production, mainly for high energy detectors calibration, it can provide electrons and positrons in a wide range of multiplicity: between 1-1010, with energies from a few tens of MeV up to 800 MeV. The large multiplicity range requires many different diagnostic devices, from high-energy calorimeters and ionization/fluorescence chambers in the few particles range, to standard beam diagnostics systems. The schemes of operation, the commissioning results, as well as the beam diagnostics are presented.

  20. Test Beams and Polarized Fixed Target Beams at the NLC

    OpenAIRE

    Keller, Lewis; Pitthan, Rainer; Rokni, Sayed; Thompson, Kathleen; Kolomenski, Yury

    2001-01-01

    A conceptual program to use NLC beams for test beams and fixed target physics is described. Primary undisrupted polarized beams would be the most simple to use, but for NLC, the disrupted beams are of good enough quality that they could also be used, after collimation of the low energy tails, for test beams and fixed target physics. Pertinent issues are: what is the compelling physics, what are the requirements on beams and running time, and what is the impact on colliding beam physics runni...

  1. Cholesterol testing and results

    Science.gov (United States)

    Cholesterol test results; LDL test results; VLDL test results; HDL test results; Coronary risk profile results; Hyperlipidemia-results; Lipid disorder test results; Heart disease - cholesterol results

  2. First results from a beam test of a high-granularity silicon-based calorimeter for CMS at HL-LHC

    CERN Document Server

    Chatterjee, Rajdeep Mohan

    2016-01-01

    A prototype of the electromagnetic calorimeter for the CMS High Granularity Calorimeter that is being designed for the High Luminosity LHC (HL-LHC) was tested in a test beam at the Fermilab Test Beam Facility (FTBF). The detector consisted of 16 sampling layers of silicon sensors interspersed withtungsten plates for a total thickness of 15.3 X$_{0}$. Each of the hexagonal sensors were sub-divided into 128 cells, predominantly hexagonal in shape, of area ~1.1 cm$^2$. The analog signal from the 2048 cells was readout using the 64-channel SKIROC2 ASIC, developed by the LLR OMEGA group for the CALICE collaboration. Data were collected with a custom data acquisition system developed for these tests. The detector was calibrated using signals obtained with 120 GeV protons.We report here the design of the prototype detector and the results obtained from analyzing the data collected in July 2016, with electron beams at energies ranging from 4 to 32 GeV.

  3. One cryogenic collimator, tested with beam

    CERN Document Server

    EuCARD, Collaboration

    2014-01-01

    The main accelerator SIS100 of the FAIR-complex will provide heavy ion beams of highest intensities. Beam loss due to ionization is the most demanding loss mechanism at operation with high intensity, intermediate charge state heavy ions. A special synchrotron design has been developed for SIS100, aiming for hundred percent control of ionization beam loss by means of a dedicated cryogenic ion catcher system. To suppress dynamic vacuum effects, the cryocatcher system shall provide a significantly reduced effective desorption yield. The construction and test of a prototype cryocatcher is a task of the EuCARD WP8 ColMat. A prototype test setup, including cryostat has been constructed, manufactured and tested under realistic conditions with beams from the heavy ion synchrotron SIS18. The design and results are presented.

  4. Test beam results of the first CMS double-sided strip module prototypes using the CBC2 read-out chip

    Energy Technology Data Exchange (ETDEWEB)

    Harb, Ali; Hauk, Johannes; Mussgiller, Andreas [DESY-Hamburg (Germany)

    2015-07-01

    The CMS Binary Chip 2 (CBC2) is a prototype version of the front-end readout ASIC to be used in the silicon stripmodules of the CMS outer tracker during the high-luminosity phase of the LHC. The CBC2 is produced in a 130 nm CMOS technology and bump-bonded to the hybrid of the double layer silicon strip modules, the so-called 2S modules. It has 254 input channels and is designed to provide an on-board trigger with the capability of cluster-width discrimination and high-momentum track identification. In November 2013 the first 2S module prototypes equipped with CBC2 were put under test at the DESY-II test beam facility. Data was collected exploiting a beam of positrons with an energy range of 2 to 4 GeV. The test setup, the event reconstruction, and the analysis results such as beam properties, alignment, clusters properties, and per-chip efficiency are presented.

  5. Test-beam with Python

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The talk will show the current implementation of the software tool developed by Silab (Bonn) and Oxford University to analyze test beam data with Mimosa telescope. Data collected from the telescope are merged with hits recorded on pixel detectors with a FE-I4 chips, the official read-out chip of the Atlas Pixel Detector. The software tool used to collect data, pyBAR, is developed with Python as well. The test-beam analysis tool parses the data-sets, recreates the tracks, aligns the telescope planes and allows to investigate the detectors spatial properties with high resolution. This has just allowed to study the properties of brand new devices that stand as possible candidate to replace the current pixel detector in Atlas.

  6. Test beam results of the first CMS double-sided strip module prototypes using the CBC2 read-out chip

    Energy Technology Data Exchange (ETDEWEB)

    Harb, Ali, E-mail: ali.harb@desy.de; Mussgiller, Andreas; Hauk, Johannes

    2017-02-11

    The CMS Binary Chip (CBC) is a prototype version of the front-end read-out ASIC to be used in the silicon strip modules of the CMS outer tracking detector during the high luminosity phase of the LHC. The CBC is produced in 130 nm CMOS technology and bump-bonded to the hybrid of a double layer silicon strip module, the so-called 2S-p{sub T} module. It has 254 input channels and is designed to provide on-board trigger information to the first level trigger system of CMS, with the capability of cluster-width discrimination and high-p{sub T} track identification. In November 2013 the first 2S-p{sub T} module prototypes equipped with the CBC chips were put to test at the DESY-II test beam facility. Data were collected exploiting a beam of positrons with an energy ranging from 2 to 4 GeV. In this paper the test setup and the results are presented.

  7. Test beam results of the first CMS double-sided strip module prototypes using the CBC2 read-out chip

    Science.gov (United States)

    Harb, Ali; Mussgiller, Andreas; Hauk, Johannes

    2017-02-01

    The CMS Binary Chip (CBC) is a prototype version of the front-end read-out ASIC to be used in the silicon strip modules of the CMS outer tracking detector during the high luminosity phase of the LHC. The CBC is produced in 130 nm CMOS technology and bump-bonded to the hybrid of a double layer silicon strip module, the so-called 2S-pT module. It has 254 input channels and is designed to provide on-board trigger information to the first level trigger system of CMS, with the capability of cluster-width discrimination and high-pT track identification. In November 2013 the first 2S-pT module prototypes equipped with the CBC chips were put to test at the DESY-II test beam facility. Data were collected exploiting a beam of positrons with an energy ranging from 2 to 4 GeV. In this paper the test setup and the results are presented.

  8. Test beam results of the first CMS double-sided strip module prototypes using the CBC2 read-out chip

    CERN Document Server

    AUTHOR|(CDS)2083921; Mussgiller, Andreas; Hauk, Johannes

    2016-01-01

    The CMS Binary Chip (CBC) is a prototype version of the front-end read-out ASIC to be used in the silicon strip modules of the CMS outer tracking detector during the high luminosity phase of the LHC. The CBC is produced in 130 nm CMOS technology and bump-bonded to the hybrid of a double layer silicon strip module, the so-called 2S-$p_{T}$ module. It has 254 input channels and is designed to provide on-board trigger information to the first level trigger system of CMS, with the capability of cluster-width discrimination and high-$p_{T}$ track identification. In November 2013 the first 2S-$p_{T}$ module prototypes equipped with the CBC chips were put to test at the DESY-II test beam facility. Data were collected exploiting a beam of positrons with an energy ranging from 2~to 4 GeV. In this paper the test setup and the results are presented.

  9. The 2002 Test Beam DAQ

    CERN Multimedia

    Mapelli, L.

    The ATLAS Tilecal group has been the first user of the Test Beam version of the DAQ/EF-1 prototype in 2000. The prototype was successfully tested in lab in summer 1999 and it has been officially adopted as baseline solution for the Test Beam DAQ at the end of 1999. It provides the right solution for users who need to have a modern data acquisition chain for final or almost final front-end and off-detector electronics (RODs and ROD emulators). The typical architecture for the readout and the DAQ is sketched in the figure below. A number of detector crates can send data over the Read Out Link to the Read Out System. The Read Out System sends data over an Ethernet link to a SubFarm PC that provides to send the data to Central Data Recording. In 2001 also the Muon MDT group has adopted this modern DAQ where for the first time a PC-based ReadOut System has been used, instead of the VME based implementation used in 2000, and for the Tilecal DAQ in 2001. In 2002 also Tilecal has adopted the PC-based implement...

  10. Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-$\\eta$ muon system

    CERN Document Server

    Abbaneo, D; Armagnaud, C; Aspell, P; Ban, Y; Bally, S; Benussi, L; Berzano, U; Bianco, S; Bos, J; Bunkowski, K; Cai, J; Chatelain, J P; Christiansen, J; Colafranceschi, S; Colaleo, A; Conde Garcia, A; David, E; de Robertis, G; De Oliveira, R; Duarte Pinto, S; Ferry, S; Formenti, F; Franconi, L; Gnanvo, K; Gutierrez, A; Hohlmann, M; Karchin, P E; Loddo, F; Magazzú, G; Maggi, M; Marchioro, A; Marinov, A; Mehta, K; Merlin, J; Mohapatra, A; Moulik, T; Nemallapudi, M V; Nuzzo, S; Oliveri, E; Piccolo, D; Postema, H; Raffone, G; Rodrigues, A; Ropelewski, L; Saviano, G; Sharma, A; Staib, M J; Teng, H; Tytgat, M; Tupputi, S A; Turini, N; Smilkjovic, N; Villa, M; Zaganidis, N; Zientek, M

    2011-01-01

    Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \\eta |<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The construction of large-area GEM detectors is challenging both from the technological and production aspects. In view of the CMS upgrade we have designed and built the largest full-size Triple-GEM muon detector, which is able to meet the stringent requirements given the hostile environment at the high-luminosity LHC. Measurements were performed during several test beam campaigns at the CERN SPS in 2010 and 2011. The main issues under study are efficiency, spatial resolution and timing performance with different inter-electrode gap configurations and gas mixtures. In this paper results of the performance of the pro...

  11. Beam profile monitoring at the test beam line at the Compact Linear Collider test facility

    Directory of Open Access Journals (Sweden)

    M. Olvegård

    2013-08-01

    Full Text Available The Compact Linear Collider (CLIC is a study for a future linear electron-positron collider based on a two-beam acceleration scheme in which a high-intensity drive beam is decelerated in order to provide the power to accelerate the main beam for collision in the TeV range. The power extracted from the drive beam deteriorates the beam quality and increases the energy spread significantly. Monitoring of the beam properties is therefore challenging but essential. These challenges are being addressed experimentally at the CLIC test facility where up to 55% of the power is extracted from the beam in the test beam line, a small-scale version of the CLIC drive-beam decelerator, leaving the beam with a very wide energy profile. For monitoring of the transverse beam profile and Twiss parameters we use optical transition radiation screens and quadrupole scans. The intra-pulse-train energy spectrum before and after deceleration is measured with segmented beam dumps. In this paper we discuss the performance of these diagnostic devices with a particular emphasis on the large energy spread and its effect on the beam imaging techniques, and with a final outlook to the CLIC drive-beam diagnostics.

  12. Modified M20 Beam Position Monitor Testing

    Science.gov (United States)

    Koros, Jessica; Musson, John

    2017-09-01

    Beam position monitors (BPMs) are used to measure lateral beam position. Two pairs of modified wire BPMs are being evaluated for installation into the injector at Jefferson Lab (JLab). The BPMs were coated with a Non-Evaporable Getter (NEG) to aid in pumping at the electron gun, as an ultra-high vacuum is required to protect the gun and to avoid scattering the beam. Beam in the injector has a large diameter, allowing extraction of second moments to give information about beam profile and emittance. The purpose of this project is to determine the effects of NEG coating on the BPMs and to calculate second moments from beam models on the Goubau Line (G-Line). Using the G-Line, scans of the BPMs were taken before and after NEG coating. Each scan produced an electrical field map, which characterizes properties of the BPM, including scale factors and coupling. Second moments were calculated using superposition of previous scan data, and verification of this method was attempted using several beam models. Results show the BPMs responded well to NEG and that measurement of second moments is possible. Once the BPMs are installed, they will enhance gun vacuum and enable monitoring of shape and trajectory of the beam as it exits the electron gun to ensure quality beam for experiments. This work is made possible through support from NSF award 1659177 to Old Dominion University.

  13. Laser Wire and Beam Position Monitor tests

    CERN Document Server

    Boogert, S T; Lyapin, A; Nevay, L; Snuverink, J

    2013-01-01

    This subtask involved two main activities; Firstly the development and subsequent usage of high resolution beam position monitors (BPM) for the International Linear Collider (ILC) and Compact Linear Collider projects (CLIC); and secondly the development of a laser-wire (LW) transverse beam size measurement systems. This report describes the technical progress achieved at a large-scale test ILC compatible BPM system installed at the Accelerator Test Facility 2 (ATF2). The ATF2 is an energy-scaled demonstration system for the final focus systems required to deliver the particle beams to collision at the ILC and CLIC. The ATF2 cavity beam position monitor system is one of the largest of its kind and rivals systems used at free electron lasers. The ATF2 cavity beam position system has achieved a position resolutionof 250 nm (with signal attuenation) and 27 nm (without attenuation). The BPM system has been used routinely for lattice diagnostics, beam based alignment and wakefield measurements. Extensive experience...

  14. Test Beam Measurements on Picosec Gaseous Detector.

    CERN Document Server

    Sohl, Lukas

    2017-01-01

    In the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substituted. This reports describes the beam setup and measurements of different Picosec prototypes. A time resolution of under 30 ps has been measured during the test beam. This report gives an overview of my work as a Summer Student. I set up and operated a triple-GEM tracker and a trigger system for the beam. During the beam I measured different prototypes of Picosec detectors and analysed the data.

  15. Ibis DDT test results

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This document contains test results from a study done to determine the organochlorine levels in the livers of white-faced ibis from Stillwater Wildlife Management...

  16. CERN PSB Beam Tests of CNAO Synchrotron's Digital LLRF

    CERN Document Server

    Angoletta, M E; De Martinis, C; Falbo, L; Findlay, A; Foglio, R; Hunt, S; Tourres, D; Vescovi, C

    2008-01-01

    The Italian National Centre for Oncological hAdrontherapy (CNAO), in its final construction phase, uses proton and carbon ion beams to treat patients affected by solid tumours. At the heart of CNAO is a 78- meter circumference synchrotron that accelerates particles to up to 400 MeV/u. The synchrotron relies on a digital LLRF system based upon Digital Signal Processors (DSPs) and Field Programmable Gate Array (FPGA). This system implements cavity servoing and beam control capabilities, such as phase and radial loops. Beam tests of the CNAO synchrotron LLRF system were carried out at CERN's Proton Synchrotron Booster (PSB) in autumn 2007, to verify the combined DSP/FPGA architecture and the beam control capabilities. For this, a prototype version of CNAO's LLRF system was adapted to the PSB requirements. This paper outlines the prototype system layout and describes the tests carried out and their results. In particular, system architecture and beam control capabilities were successfully proven by comparison wit...

  17. Predicting the performance of the CMS precision PbWO$_4$ electromagnetic calorimeter in the HL-LHC era from test beam results on irradiated crystals

    CERN Document Server

    Zghiche, Amina

    2017-01-01

    The harsh radiation environment in which detectors will have to operate during the High Luminosity phase of the LHC (HL-LHC) represents a crucial challenge for many calorimeter technologies. In the CMS forward calorimeters, ionizing doses and hadron fluences will reach up to 300 kGy (at a dose rate of 30 Gy/h) and ${\\bf 2\\times 10^{14} cm^{-2}}$, respectively, at the pseudorapidity region of {\\bf $\\vert\\eta\\vert$}= 2.6. To evaluate the evolution of the CMS ECAL performance in such conditions, a set of \\PWO crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between ${\\bf 2.1\\times 10^{13} cm^{-2}}$ and ${\\bf 1.3\\times 10^{14} cm^{-2}}$, has been studied in beam tests. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The evolution of the performance of the PbWO$_4$ cry...

  18. Beam Test Results for New Full-scale GEM Prototypes for a Future Upgrade of the CMS High-eta Muon System

    CERN Document Server

    AUTHOR|(CDS)2067149; Armagnaud, C.; Aspell, P.; Assran, Y.; Ban, Y.; Bally, S.; Benussi, L.; Berzano, U.; Bianco, S.; Bos, J.; Bunkowski, K.; Cai, J.; Chatelain, J.P.; Christiansen, J.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; David, E.; de Robertis, G.; De Oliveira, R.; Duarte Pinto, S.; Ferry, S.; Formenti, F.; Franconi, L.; Fruboes, T.; Gutierrez, A.; Hohlmann, M.; Kamel, A.E.; Karchin, P.E.; Loddo, F.; Magazzu, G.; Maggi, M.; Marchioro, A.; Marinov, A.; Mehta, K.; Merlin, J.; Mohapatra, A.; Moulik, T.; Nemallapudi, M.V.; Nuzzo, S.; Oliveri, E.; Piccolo, D.; Postema, H.; Radi, A.; Raffone, G.; Rodrigues, A.; Ropelewski, L.; Saviano, G.; Sharma, A.; Staib, M.J.; Teng, H.; Tytgat, M.; Tupputi, S.A.; Turini, N.; Smilkjovic, N.; Villa, M.; Zaganidis, N.; Zientek, M.

    2012-01-01

    The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly technique, we built four full-scale Triple-GEM muon detectors for the inner ring of the first muon endcap station. We plan to install these or further improved versions in CMS during the first long LHC shutdown in 2013/14 for continued testing. These detectors are designed for the stringent rate and resolution requirements in the increasingly hostile environments expected at CMS after the second long LHC shutdown in 2018/19. The new prototypes were studied in muon/pion beams at the CERN SPS. We discuss our experience with constructing the new full-scale production prototypes and present preliminary performance r...

  19. ALICE Transition Radiation Detector (TRD), test beam.

    CERN Multimedia

    2003-01-01

    Electrons and positrons can be discriminated from other charged particles using the emission of transition radiation - X-rays emitted when the particles cross many layers of thin materials. To develop such a Transition Radiation Detector(TRD) for ALICE many detector prototypes were tested in mixed beams of pions and electrons, as in the example shown here.

  20. Test beam performance of the ALICE silicon pixel detector

    CERN Document Server

    Nilsson, P; Ohnishi, H; Olmos-Giner, A; Osmic F; Pappalardo, G S; Anelli, G; Antinori, F; Boccardi, A; Burns, M; Cali, I A; Campbell, M; Caselle, M; Chochula, P; Cinausero, M; D'Alessandro, A; Dima, R; Dinapoli, R; Elia, D; Enyo, H; Fabris, D; Fini, R; Fioretto, E; Formenti, F; Fujiwara, K; Heuser, J M; Kano, J; Kapusta, S; Kluge, A; Krivda, M; Lenti, V; Librizzi, F; Lunardon, M; Manzari, V; Morel, M; Olmos-Giner, A; Osmic, F; Pepato, Adriano; Prete, G; Riedler, P; Santoro, R; Scarlassara, F; Segato, G F; Soramel, F; Stefanini, G; Tanida, K; Taketani, A; Turrisi, R; Vannucci, L; Viesti, G; Virgili, T

    2004-01-01

    The ALICE Silicon Pixel Detector (SPD) will include 1200 bump-bonded readout chips produced in a commercial 0.25 mu CMOS process. Each chip has 8192 pixels of size 50 * 425 mu m/sup 2/, which leads to about 10 million readout channels in the whole detector system. Test beam measurements were recently carried out at the CERN SPS using a positive proton/pion beam as well as a 158 AGeV/c heavy ion beam (In) with a fixed Pb target. Analysis show good performance of the ALICE chip and assemblies in the positive beam as well as in the high multiplicity In beam. Preliminary results from data analysis show good performance of the SPD and fulfill the ALICE requirements.

  1. Flexural Test of Fly Ash based Geopolimer Concrete Beams

    Directory of Open Access Journals (Sweden)

    Nindyawati

    2017-01-01

    Full Text Available Fly ash is a by-product from the coal industry, which is widely available in Indonesia. Fly ash contains quite high silicate and alumina. Silica and alumina reacts with alkaline solution to produce alumina silicate gel which binds the aggregate to produce geopolymer concrete. Geopolymer concrete is introduced as an environmental concrete with high compressive strength. The use of geopolymer concrete beams is a solution to reduce the effects of greenhouse gases. This research uses experimental designs. The data are obtained from the testing of 4 pieces of reinforced geopolymer concrete beams and reinforced ordinary concrete beams with a / d of 1.11 and 2.24. The results are obtained from the maximum load that can be accepted by the beam. The results of this study are: (1 Geopolymer concrete cylinder has 26.78% higher compressive strength than ordinary concrete cylinders (2 Ordinary concrete beams can withstand 34.8% load higher compared to the geopolymer concrete beam (3 Reinforced ordinary concrete beams experience bending shear collapse while reinforced geopolymer concrete beam experience pure bending collapse.

  2. Results from the HiRadMat Primary Beam Line Commissioning

    CERN Document Server

    Hessler, C; Bauche, J; Bestmann, K; Blanco Sancho, J; Conan, N; Cornelis, K; Efthymiopoulos, I; Gaillard, H; Goddard, B; Grenier, D; Gros, G; Habert, A; Jensen, L; Kain, V; Le Godec, G; Meddahi, M; Pelletier, S; Pepinster, P; Puccio, B; Theis, C; Trilhe, P; Vandoni, G; Wenninger, J

    2011-01-01

    The High Radiation to Materials facility (HiRadMat) is a new experimental area at CERN, for studies of the impact of high-intensity pulsed beams on accelerator components and materials. The beam is delivered from the SPS by a new primary beam line, which has been constructed during the 2010/11 winter technical stop. The paper summarizes the construction phase and describes the results from the beam line commissioning in spring 2011. Beam parameter and aperture measurements are presented, as well as steering tests. A special emphasis has been put on the handling of the exceptionally flexible beam line optics in the control system.

  3. Pixel-Tilecal-MDT Combined Test Beam

    CERN Document Server

    B. Di Girolamo

    A test with many expectations When an additional week of running (from September 11th to 18th) was allocated for the test-beam, it was decided to give priority to a combined run with the participation of the Pixel, Tilecal and MDT sub-detectors. The integration of these three sub-detectors was possible as they all use the baseline (DAQ-1/EF based) DAQ for test beams (as reported in a previous e-news). The tests and the addition of a common trigger and busy were organized in a short timescale by experts from the three sub-detectors and DAQ/EF. The expectations were many; both looking for problems and finding solutions. The setup The setup, shown in the figure, consisted of the Pixel telescope normally used during the sub-detector tests, two Tilecal barrel modules, two Tilecal extended barrel modules, and six MDT barrel chambers. This fully occupied a length of some 30 meters in the H8 line of the SPS North Area. Each sub-detector used their own specialized front-end electronics. The data collected by modu...

  4. Molecular beam simulation of planetary atmospheric entry: Some recent results

    Science.gov (United States)

    French, J. B.; Reid, N. M.

    1972-01-01

    Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of the simulation technique are discussed. It is shown that an open cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen. The simulation techniques used provide assistance in designing, developing, and (potentially) in testing and calibrating the required flight instrument.

  5. Pulsed beam tests at the SANAEM RFQ beamline

    Science.gov (United States)

    Turemen, G.; Akgun, Y.; Alacakir, A.; Kilic, I.; Yasatekin, B.; Ergenlik, E.; Ogur, S.; Sunar, E.; Yildiz, V.; Ahiska, F.; Cicek, E.; Unel, G.

    2017-07-01

    A proton beamline consisting of an inductively coupled plasma (ICP) source, two solenoid magnets, two steerer magnets and a radio frequency quadrupole (RFQ) is developed at the Turkish Atomic Energy Authority’s (TAEA) Saraykoy Nuclear Research and Training Center (SNRTC-SANAEM) in Ankara. In Q4 of 2016, the RFQ was installed in the beamline. The high power tests of the RF power supply and the RF transmission line were done successfully. The high power RF conditioning of the RFQ was performed recently. The 13.56 MHz ICP source was tested in two different conditions, CW and pulsed. The characterization of the proton beam was done with ACCTs, Faraday cups and a pepper-pot emittance meter. Beam transverse emittance was measured in between the two solenoids of the LEBT. The measured beam is then reconstructed at the entrance of the RFQ by using computer simulations to determine the optimum solenoid currents for acceptance matching of the beam. This paper will introduce the pulsed beam test results at the SANAEM RFQ beamline. In addition, the high power RF conditioning of the RFQ will be discussed.

  6. Tests of beam-based alignement at FACET

    CERN Document Server

    Latina, A; Schulte, D; Adli, E

    2014-01-01

    The performance of future linear colliders will depend critically on beam-based alignment (BBA) and feedback systems, which will play a crucial role in guaranteeing the low emittance transport throughout such machines. BBA algorithms designed to improve the beam transmission in a linac by simultaneously optimising the trajectory and minimising the residual dispersion, have thoughtfully been studied in theory over the last years, and successfully verified experimentally. One such technique is called Dispersion-Free Steering (DFS). A careful study of the DFS performance at the SLAC test facility FACET lead us to design a beam-based technique specifically targeted to reduce the impact of transverse short-range wakefields, rather than of the dispersion, being the wakefields the limiting factor to the FACET performance. This technique is called Wakefield-Free Steering (WFS). The results of the first tests of WFS at FACET are presented in this paper.

  7. Beam test performance of the SKIROC2 ASIC

    Energy Technology Data Exchange (ETDEWEB)

    Amjad, M.S. [Laboratoire de l' Accélérateur Linéaire, Centre Scientifique d' Orsay, Université de Paris-Sud XI, CNRS/IN2P3, F-91898 Orsay Cedex (France); Anduze, M. [Laboratoire Leprince-Ringuet, École Polytechnique, CNRS/IN2P3, F-91128 Palaiseau (France); Augustin, J.-E. [Laboratoire de Physique Nucléaire et de Hautes Energies, UPMC, Université Paris Diderot, CNRS/IN2P3, Paris (France); Bonis, J. [Laboratoire de l' Accélérateur Linéaire, Centre Scientifique d' Orsay, Université de Paris-Sud XI, CNRS/IN2P3, F-91898 Orsay Cedex (France); Boudry, V. [Laboratoire Leprince-Ringuet, École Polytechnique, CNRS/IN2P3, F-91128 Palaiseau (France); Bourgeois, C. [Laboratoire de l' Accélérateur Linéaire, Centre Scientifique d' Orsay, Université de Paris-Sud XI, CNRS/IN2P3, F-91898 Orsay Cedex (France); Brient, J.-C. [Laboratoire Leprince-Ringuet, École Polytechnique, CNRS/IN2P3, F-91128 Palaiseau (France); Callier, S. [OMEGA, École Polytechnique, CNRS/IN2P3, F-91128 Palaiseau (France); Cerutti, M. [Laboratoire Leprince-Ringuet, École Polytechnique, CNRS/IN2P3, F-91128 Palaiseau (France); Chen, S. [Department of Physics, Graduate School of Science, The University of Tokyo, Tokyo 113-0033 (Japan); Cornat, R. [Laboratoire Leprince-Ringuet, École Polytechnique, CNRS/IN2P3, F-91128 Palaiseau (France); and others

    2015-04-01

    Beam tests of the first layers of CALICE silicon tungsten ECAL technological prototype were performed in April and July 2012 using 1–6 GeV electron beam at DESY. This paper presents an analysis of the SKIROC2 readout ASIC performance under test beam conditions.

  8. Beam test performance of the SKIROC2 ASIC

    CERN Document Server

    Frisson, T; Anduze, M; Augustin, J.E; Bonis, J; Boudry, V; Bourgeois, C; Brient, J.C; Callier, S; Cerutti, M; Chen, S; Cornat, R; Cornebise, P; Cuisy, D; David, J; De la Taille, C; Dulucq, F; Frotin, M; Gastaldi, F; Ghislain, P; Giraud, J; Gonnin, A; Grondin, D; Guliyev, E; Hostachy, J.Y; Jeans, D; Kamiya, Y; Kawagoe, K; Kozakai, C; Lacour, D; Lavergne, L; Lee, S.H; Magniette, F; Ono, H; Poeschl, R; Rouëné, J; Seguin-Moreau, N; Song, H.S; Sudo, Y; Thiebault, A; Tran, H; Ueno, H; Van der Kolk, N; Yoshioka, T

    2015-01-01

    Beam tests of the first layers of CALICE silicon tungsten ECAL technological prototype were performed in April and July 2012 using 1–6 GeV electron beam at DESY. This paper presents an analysis of the SKIROC2 readout ASIC performance under test beam conditions.

  9. Shear or bending? Experimental results on large t-shaped prestressed conrete beams

    NARCIS (Netherlands)

    Ensink, S.W.H.; Van der Veen, C.; De Boer, A.

    2015-01-01

    Experimental results of four shear tests on two large prestressed concrete beams are compared to nonlinear analysis and design code calculations. The beams have a length of 12 m and a depth of 1.3 m and are reinforced with stirrups and pre-tensioning. The four tests consist of a single point load at

  10. Test beam results on Atlas electromagnetic end-cap calorimeter: Electrons-jets separation; Resultats des tests en faisceau sur les bouchons du calorimetre electromagnetique d'ATLAS - separation electrons-jets

    Energy Technology Data Exchange (ETDEWEB)

    Serfon, C

    2005-05-15

    ATLAS is one of the four experiments being built on the future proton-proton collider at CERN: the LHC. This experiment has a large physics program, from Standard Model to new physics. The search for the Higgs boson in two photons or in four leptons, or the search of Z' or W' needs a good energy resolution for the electromagnetic calorimeter. This thesis describes the beam tests performed on three modules of the electromagnetic end cap calorimeter. A 0.6% non-uniformity, and a 0.7% energy resolution global constant term (dominant at high energy) has been obtained. Moreover, a study on the separation between electrons and jets is also performed. This study shows that a jets rejection factor of 10{sup 5} can be obtained keeping an electron efficiency better than 78%. (author)

  11. Collimation quench test with 4 TeV proton beams

    CERN Document Server

    Salvachua, B; Cauchi, M; Deboy, D; Hofle, W; Holzer, EB; Jacquet, D; Lari, L; Nebot, E; Mirarchi, D; Quaranta, E; Redaelli, S; Sapinski, M; Schmidt, R; Valentino, G; Valuch, D; Wenniger, J; Wollmann, D; Zerlauth, M; CERN. Geneva. ATS Department

    2014-01-01

    In 2013, at the end of the LHC physics run I, several quench tests took place with the aim to measure the quench limit of the LHC superconducting magnets. The LHC superconducting magnets in the dispersion suppressor of IR7 are the most exposed to beam losses leaking from the betatron collimation system and represent the main limitation for the halo cleaning. A collimation quench test was performed with 4 TeV proton beams to improve the quench limit estimates, which determine the maximum allowed beam loss rate for a given collimation cleaning. The main goal of the collimation quench test was to try to quench the magnets by increasing losses at the collimators. This note describes the procedure during the test and the first results with the data. Losses of up to 1 MW over a few seconds were generated by blowing up the beam, achieving total losses of about 5.8 MJ. These controlled losses exceeded by a factor 2 the collimation design value, and the magnets did not quench.

  12. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  13. Tests of a High Resolution Beam Profile Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Norem, J.

    2004-10-28

    High energy linear colliders require very small beams at the interaction point to produce high luminosities, and these beams must be measured and monitored. We have developed and tested a technique where the profile can be obtained from an extension of pinhole camera optics using thick, single sided collimators and slits. Very high resolutions (a few nm) should be possible. Gamma beams can be obtained from bremsstrahlung, Compton or beamstrahlung radiation. We describe tests of the technique using bremsstrahlung from an 800 MeV electron beam at Bates/MIT, Compton scattered photons from 47 GeV Final Focus Test Beam (FFTB) at SLAC, and other applications, such as linear colliders.

  14. Beam Line Design for the CERN Hiradmat Test Facility

    OpenAIRE

    Hessler, C.; Assmann, R.; Goddard, B; Meddahi, M; Weterings, W

    2009-01-01

    The LHC phase II collimation project requires beam shock and impact tests of materials used for beam intercepting devices. Similar tests are also of great interest for other accelerator components such as beam entrance/exit windows and protection devices. For this purpose a dedicated High Radiation Material test facility (HiRadMat) is under study. This facility may be installed at CERN at the location of a former beam line. This paper describes the associated beam line which is foreseen to de...

  15. High luminosity liquid-argon calorimeter test beam

    Energy Technology Data Exchange (ETDEWEB)

    Novgorodova, Olga; Straessner, Arno [TU Dresden, IKTP (Germany)

    2016-07-01

    In the future HL-LHC the luminosity will increase by factor of 5-7 with respect to the original LHC design. The HiLum collaboration studied the impact on small-sized modules of the ATLAS electromagnetic, hadronic, and forward calorimeters also instrumented by various intensity and position detectors. The intensity of beam varied over a wide range (10{sup 6} to 10{sup 12} p/s) and beyond the maximum expected at HL-LHC for these calorimeters. Results from the last test beam campaign in 2013 on the signal shape analysis from the calorimeter modules are compared with MC simulations. The correlation between high-voltage return currents of the electromagnetic calorimeter and beam intensity is used to estimate critical parameters and compared with predictions.

  16. Preliminary results of proton beam characterization for a facility of broad beam in vitro cell irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Wera, A.-C. [Laboratoire d' Analyses par Reactions Nucleaires (LARN), University of Namur-FUNDP, Rue de Bruxelles, 61, B-5000 Namur (Belgium)], E-mail: anne-catherine.wera@fundp.ac.be; Donato, K. [Ion Beam Application, Chemin du Cyclotron 3, B-1348 Louvain-la-Neuve (Belgium); Michiels, C. [Unite de Recherche en Biologie Cellulaire (URBC), University of Namur-FUNDP (Belgium); Jongen, Y. [Ion Beam Application, Chemin du Cyclotron 3, B-1348 Louvain-la-Neuve (Belgium); Lucas, S. [Laboratoire d' Analyses par Reactions Nucleaires (LARN), University of Namur-FUNDP, Rue de Bruxelles, 61, B-5000 Namur (Belgium)

    2008-05-15

    The interaction of charged particles with living matter needs to be well understood for medical applications. Particularly, it is useful to study how ion beams interact with tissues in terms of damage, dose released and dose rate. One way to evaluate the biological effects induced by an ion beam is by the irradiation of cultured cells at a particle accelerator, where cells can be exposed to different ions at different energies and flux. In this paper, we report the first results concerning the characterization of a broad proton beam obtained with our 2 MV tandem accelerator. For broad beam in vitro cell irradiation, the beam has to be stable over time, uniform over a {approx}0.5 cm{sup 2} surface, and a dose rate ranging from 0.1 to 10 Gy/min must be achievable. Results concerning the level of achievement of these requirements are presented in this paper for a 1 MeV proton beam.

  17. First test of BNL electron beam ion source with high current density electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Pikin, Alexander, E-mail: pikin@bnl.gov; Alessi, James G., E-mail: pikin@bnl.gov; Beebe, Edward N., E-mail: pikin@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States); Shornikov, Andrey; Mertzig, Robert; Wenander, Fredrik; Scrivens, Richard [CERN, CH-1211 Geneva 23 (Switzerland)

    2015-01-09

    A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm{sup 2} and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, the EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given.

  18. Modelling and Testing of the Piezoelectric Beam as Energy Harvesting System

    Directory of Open Access Journals (Sweden)

    Koszewnik Andrzej

    2016-12-01

    Full Text Available The paper describes modelling and testing of the piezoelectric beam as energy harvesting system. The cantilever beam with two piezo-elements glued onto its surface is considered in the paper. As result of carried out modal analysis of the beam the natural frequencies and modes shapes are determined. The obtained results in the way mentioned above allow to estimate such location of the piezo-actuator on the beam where the piezo generates maximal values of modal control forces. Experimental investigations carried out in the laboratory allow to verify results of natural frequencies obtained during simulation and also testing of the beam in order to obtain voltage from vibration with help of the piezo-harvester. The obtained values of voltage stored on the capacitor C0 shown that the best results are achieved for the beam excited to vibration with third natural frequency, but the worst results for the beam oscillating with the first natural frequency.

  19. The 2004 ATLAS Combined Test Beam

    CERN Multimedia

    The ATLAS CTB Team, .

    2004-01-01

    In the year 2004, ATLAS has been involved in a huge combined test beam (CTB) effort in H8. A complete slice of the barrel detector and of the Muon End-cap has been tested, with the following clear goals: pre-commission the final elements and study the detector performance in a realistic combined data taking. Thanks to this experience, a lot of expertise in the operations has been acquired and much data (~ 4.6 TB of data, ~ 90 million events on castor) has been collected and is already under analysis. The CTB has been characterized by different phases with an incremental presence of sub-detectors modules and associated DAQ infrastructure, as well as incremental improvement of analysis tools for prompt data certification. The physics goals of the CTB have been defined in consultation with the physics coordinator, all the sub-detector representatives and the combined performance group representative. With all these indications, a detailed run plan day-by-day schedule was defined before the CTB start and was foll...

  20. ATLAS TRT Barrel in Test Beam

    CERN Multimedia

    Luehring, F

    In July, the TRT group made a highly successful test of 6 Barrel TRT modules in the ATLAS H8 testbeam. Over 3000 TRT straw tubes (4 mm diameter gas drift tubes) were instrumented and found to operate well. The prototype represents 1/16 of the ATLAS TRT barrel and was assembled from TRT modules produced as spares. This was the largest scale test of the TRT to this date and the measured detector performance was as good as or better than what was expected in all cases. The 2004 TRT testbeam setup before final cabling was attached. The readout chain and central DAQ system used in the TRT testbeam is a final prototype for the ATLAS experiment. The TRT electronics used to read out the data were: The Amplifier/Shaper/Discriminator with Baseline Restoration (ASDBLR) chip is the front-end analog chip that shapes and discriminates the electronic pulses generated by the TRT straws. The Digital Time Measurement Read Out Chip (DTMROC) measures the time of the pulse relative to the beam crossing time. The TRT-ROD ...

  1. Experimental results of beryllium exposed to intense high energy proton beam pulses

    CERN Document Server

    Ammigan, K; Hurh, P; Zwaska, R; Butcher, M; Guinchard, M; Calviani, M; Losito, R; Roberts, S; Kuksenko, V; Atherton, A; Caretta, O; Davenne, T; Densham, C; Fitton, M; Loveridge, J; O'Dell, J

    2017-01-01

    Beryllium is extensively used in various accelerator beam lines and target facilities as a material for beam windows, and to a lesser extent, as secondary particle production targets. With increasing beam intensities of future accelerator facilities, it is critical to understand the response of beryllium under extreme conditions to reliably operate these components as well as avoid compromising particle production efficiency by limiting beam parameters. As a result, an exploratory experiment at CERN’s HiRadMat facility was carried out to take advantage of the test facility’s tunable high intensity proton beam to probe and investigate the damage mechanisms of several beryllium grades. The test matrix consisted of multiple arrays of thin discs of varying thicknesses as well as cylinders, each exposed to increasing beam intensities. This paper outlines the experimental measurements, as well as findings from Post-Irradiation-Examination (PIE) work where different imaging techniques were used to analyze and co...

  2. Beam Tests of a Prototype Stripline Beam Position Monitoring System for the Drive Beam of the CLIC Two-beam Module at CTF3

    CERN Document Server

    Benot-Morell, Alfonso; Nappa, Jean-Marc; Vilalte, Sebastien; Wendt, Manfred

    2016-01-01

    In collaboration with LAPP and IFIC, two units of a prototype stripline Beam Position Monitor (BPM) for the CLIC Drive Beam (DB), and its associated readout electronics have been successfully installed and tested in the Two-Beam-Module (TBM) at the CLIC Test Facility 3 (CTF3) at CERN. This paper gives a short overview of the BPM system and presents the performance measured under different Drive Beam configurations.

  3. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility.

  4. Recent results of radioactive beam experiments at ATLAS

    CERN Document Server

    Rehm, K E

    2001-01-01

    Various beams of short- and long-lived radioactive nuclei have recently been produced at the ATLAS accelerator at Argonne National Laboratory, using either the so-called In-Flight or the Two- Accelerator method. With these beams many questions which are of interest in the areas of nuclear structure and nuclear astrophysics can be addressed. In this contribution first results from experiments with /sup 44/Ti (T/sub 1/2/=60y) and /sup 17/F (T/sub 1/2/=64s) beams are discussed, which are of interest to the nucleosynthesis in supernovae and X-ray bursts. (28 refs).

  5. Results from the SLAC NLC test accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Ruth, R.D.; Adolphsen, C.; Allison, S. [and others

    1997-06-01

    The design for the Next Linear Collider (NLC) at SLAC is based on two 11.4 GHz linacs operating at an unloaded acceleration gradient of 50 MV/m increasing to 85 MV/m as the energy is increased from 1/2 TeV to 1 TeV in the center of mass. During the past several years there has been tremendous progress on the development of 11.4 GHz (X-band) RF systems. These developments include klystrons which operate at the required powder and pulse length, pulse compression systems that achieve a factor of four power multiplication and structures that are specially designed to reduce long-range wakefields. Together with these developments, we have constructed a 1/2 GeV test accelerator, the NLC Test Accelerator (NLCTA). The NLCTA will serve as a test bed as the design of the NLC is refined. In addition to testing the RF system, the NLCTA is designed to address many questions related to the dynamics of the beam during acceleration, in particular, multibunch beam-loading compensation and transverse beam break-up. In this paper we describe the NLCTA and present results from initial experiments.

  6. Directed Beam Alignment System Testing Program.

    Science.gov (United States)

    1979-06-04

    4 2.1.1 Handover Based on DBAS Alignment ........... 7 2.2 Conceptoal Implementation of DBAS .... ........... 8 3.0 Breadboard...A SCATTERING PHENOMENOLOGY When an electromagnetic wave propagates through any passive media , energy is removed from the radiation beam. The relative...amount of energy/ power removed from the beam per unit length of propagation defines the extinction coefficient for the media and is I dP Yext = P

  7. A beam test of prototype time projection chamber using micro ...

    Indian Academy of Sciences (India)

    Abstract. We conducted a series of beam tests of prototype TPCs for the international linear collider (ILC) experiment, equipped with an MWPC, a MicroMEGAS, or GEMs as a readout device. The prototype operated successfully in a test beam at KEK under an axial magnetic field of up to 1 T. The analysis of data is now in ...

  8. Beam tests on a proton linac booster for hadron therapy

    CERN Document Server

    De Martinis, C; Berra, P; Birattari, C; Calabretta, L; Crandall, K; Giove, D; Masullo, M R; Mauri, M; Rosso, E; Rovelli, A; Serafini, L; Szeless, Balázs; Toet, D Z; Vaccaro, Vittorio G; Weiss, M; Zennaro, R

    2002-01-01

    LIBO is a 3 GHz modular side-coupled proton linac booster designed to deliver beam energies up to 200 MeV, as required for the therapy of deep seated tumours. The injected beam of 50 to 70 MeV is produced by a cyclotron like those in several hospitals and research institutes. A full-scale prototype of the first module with an input/output energy of 62/74 MeV, respectively, was designed and built in 1999 and 2000. Full power RF tests were carried out successfully at CERN using a test facility at LIL at the end of the year 2000. In order to prove the feasibility of the acceleration process, an experimental setup with this module was installed at the INFN Laboratorio Nazionale del Sud (LNS) in Catania during 2001. The superconducting cyclotron provided the 62 MeV test beam. A compact solid-state RF modulator with a 4 MW klystron, made available by IBA-Scanditronix, was put into operation to power the linac. In this paper the main features of the accelerator are reviewed and the experimental results obtained duri...

  9. LHCb Scintillating Fibre Tracker: Test Beam Report 2015

    CERN Document Server

    Rodrigues Cavalcante, Ana Barbara; Gavardi, Laura; Girard, Olivier Goran; Greim, Roman; Haefeli, Guido; Han, Xiaoxue; Joram, Christian; Kecke, Matthieu; Kuonen, Axel Kevin; Leverington, Blake Dean; Mitzel, Dominik Stefan; Muller, Janine; Neuner, Max; Nieswand, Simon; Tekampe, Tobias

    2015-01-01

    This document summarizes the testbeam results of scintillating fibre mats tested at the SPS at CERN in May and November of 2015. Fibre mats consisting of 5, 6, and 8 layers (with a wider pitch) were tested for their light yield, attenuation length, single hit efficiency, and position resolution. In November 2016, one 6-layer module was additionally irradiated to the LHCb-Upgrade dose profile for fibre mats next to the beam pipe. The loss in signal was measured near the mirror.

  10. Results from the LHC Beam Dump Reliability Run

    CERN Document Server

    Uythoven, J; Carlier, E; Castronuovo, F; Ducimetière, L; Gallet, E; Goddard, B; Magnin, N; Verhagen, H

    2008-01-01

    The LHC Beam Dumping System is one of the vital elements of the LHC Machine Protection System and has to operate reliably every time a beam dump request is made. Detailed dependability calculations have been made, resulting in expected rates for the different system failure modes. A 'reliability run' of the whole system, installed in its final configuration in the LHC, has been made to discover infant mortality problems and to compare the occurrence of the measured failure modes with their calculations.

  11. Beam Test of Gamma-ray Large Area Space Telescope Components

    Energy Technology Data Exchange (ETDEWEB)

    Bloom, Elliott D

    1999-05-27

    A beam test of GLAST (Gamma-ray Large Area Space Telescope) components was performed at the Stanford Linear Accelerator Center in October, 1997. These beam test components were simple versions of the planned light hardware. Results on the performance of the tracker, calorimeter, and anticoincidence charged particle veto are presented.

  12. Beam profile monitoring at the test beam line at the Compact Linear Collider test facility

    OpenAIRE

    Olvegård, M.; Adli, E.; Andreazza, W; Bolzon, B; Bravin, E.; Chritin, N; Dabrowski, A.; Döbert, S; Duraffourg, M; Lefèvre, T.; Lillestøl, R.; Ziemann, V.

    2013-01-01

    The Compact Linear Collider, CLIC is a study for a future linear electron-positron collider based on a two-beam acceleration scheme in which a high intensity drive beam is decelerated in order to provide the power to accelerate the main beam for collision in the TeV range. The power extracted from the drive beam deteriorates the beam quality and increases the energy spread significantly. Monitoring of the beam properties is therefore challenging but essential. These challenges are being addre...

  13. Testing beam-induced quench levels of LHC superconducting magnets

    Directory of Open Access Journals (Sweden)

    B. Auchmann

    2015-06-01

    Full Text Available In the years 2009–2013 the Large Hadron Collider (LHC has been operated with the top beam energies of 3.5 and 4 TeV per proton (from 2012 instead of the nominal 7 TeV. The currents in the superconducting magnets were reduced accordingly. To date only seventeen beam-induced quenches have occurred; eight of them during specially designed quench tests, the others during injection. There has not been a single beam-induced quench during normal collider operation with stored beam. The conditions, however, are expected to become much more challenging after the long LHC shutdown. The magnets will be operating at near nominal currents, and in the presence of high energy and high intensity beams with a stored energy of up to 362 MJ per beam. In this paper we summarize our efforts to understand the quench levels of LHC superconducting magnets. We describe beam-loss events and dedicated experiments with beam, as well as the simulation methods used to reproduce the observable signals. The simulated energy deposition in the coils is compared to the quench levels predicted by electrothermal models, thus allowing one to validate and improve the models which are used to set beam-dump thresholds on beam-loss monitors for run 2.

  14. Beam Tests of the Balloon-Borne ATIC Experiment

    Science.gov (United States)

    Ganel, O.; Adams, J. H., Jr.; Ahn, E. J.; Ampe, J.; Bashindzhagyan, G.; Case, G.; Chang, J.; Ellison, S.; Fazely, A.; Gould, R.

    2003-01-01

    The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic-ray elemental spectra measurement from 50 GeV to 100 TeV for nuclei from hydrogen to iron. These measurements are expected to provide crucial hints about some of the most fundamental questions in astroparticle physics today. ATTIC'S design centers on an 18 radiation length (X(sub Omnicron)) deep bismuth germanate (BGO) calorimeter, preceded by a 0.75 lambda(sub int) graphite target. In September 1999 the ATIC detector was exposed to high-energy beams at CERN's SPS accelerator, within the framework of the development program for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). In December 2000 - January 2001, ATIC flew on the first of a series of long duration balloon (LDB) flights from McMurdo Station, Antarctica. We present here results from the 1999 beam-tests, including energy resolutions for electrons and protons at several beam energies from 100 GeV to 375 GeV, as well as signal linearity and collection efficiency estimates. We show how these results compare with expectations based on simulations, and their expected impacts on mission performance.

  15. Beam-induced quench test of LHC main quadrupole

    CERN Document Server

    Priebe, A; Dehning, B; Effinger, E; Emery, J; Holzer, E B; Kurfuerst, C; Nebot Del Busto, E; Nordt, A; Sapinski, M; Steckert, J; Verweij, A; Zamantzas, C

    2011-01-01

    Unexpected beam loss might lead to a transition of the accelerator superconducting magnet to a normal conducting state. The LHC beam loss monitoring (BLM) system is designed to abort the beam before the energy deposited in the magnet coils reach a quench-provoking level. In order to verify the threshold settings generated by simulation, a series of beam-induced quench tests at various beam energies has been performed. The beam losses are generated by means of an orbital bump peaked in one of main quadrupole magnets (MQ). The analysis includes not only BLM data but also the quench protection system (QPS) and cryogenics data. The measurements are compared to Geant4 simulations of energy deposition inside the coils and corresponding BLM signal outside the cryostat.

  16. The Datura Pixel Beam Telescope - Setup and first results

    Energy Technology Data Exchange (ETDEWEB)

    Eckstein, Doris; Eichhorn, Thomas; Gregor, Ingrid-Maria; Rubinskiy, Igor; Perrey, Hanno [DESY (Germany)

    2013-07-01

    The Datura pixel telescope is an upgraded version of the original Eudet beam telescope. It consists of six planes of Mimosa 26 monolithic active pixel sensors, mounted on two lever arms with three planes each. The sensor positioning is flexible and there is the possibility of including a central device under test (DUT). With the telescope, a pointing precision of under 3 μm at the DUT can be achieved. Cooling of sensors and DUT, positioning and read-out infrastructure are included. The telescope provides a flexible and general purpose testing environment for various sensor technologies. In this talk telescope resolution measurements at the low energy DESY e{sup +}/e{sup -} test beam are presented.

  17. Gap application results for adjacent electron beams treatment

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio, Francisco G.A., E-mail: francisampaio@pg.ffclrp.usp.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Del Lama, Lucas S., E-mail: lucasdellama@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Petchevist, Paulo C.D., E-mail: petchevist12@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Instituto de Radioterapia e Megavoltagem de Ribeirao Preto - IRMEV, Rua Sete de Setembro 1150, CEP 14010-180, Ribeirao Preto, SP (Brazil); Moreira, Marcos V., E-mail: marcos_vasques@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Instituto de Radioterapia e Megavoltagem de Ribeirao Preto - IRMEV, Rua Sete de Setembro 1150, CEP 14010-180, Ribeirao Preto, SP (Brazil); Almeida, Adelaide de, E-mail: dalmeida@ffclrp.usp.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil)

    2011-12-15

    Nowadays, electron beams from high-energy linear accelerators (LINAC) are widely used in a variety of radiotherapy treatments being suitable especially for superficial tumors. Since this sort of ionizing radiation has stopping power higher than photons, deeper and healthier tissues can be preserved. On the other hand, when applying adjacent electron beams, 'hot' spots can be observed, due to penumbra and/or scattering, contributing to the increase of the absorbed dose in the target volume. In this sense, the objective of this work was to investigate the effects of parallel adjacent electron beams using the chemical dosimeter Fricke Xylenol Gel (FXG) and compare the experimental results with ones acquired using Monte Carlo simulation. Thus, 10 Multiplication-Sign 10, 15 Multiplication-Sign 15 and 20 Multiplication-Sign 20 cm{sup 2} fields were irradiated with 5, 8 and 10 MeV electron beams applying different gap widths. The experimental results and the simulations indicated overdose values up to 40% from the prescribed one for the specific tumor. This demonstrates that specific gaps are necessary in the case of treatments with parallel adjacent electron beams in order to prevent overdoses in the depth of interest.

  18. Beam tests of the balloon-borne ATIC experiment

    CERN Document Server

    Ganel, O; Ahn, H S; Ampe, J; Bashindzhagian, G L; Case, G; Chang, H; Ellison, S; Fazely, A; Gould, R; Granger, D; Gunasingha, R M; Guzik, T G; Han, Y J; Isbert, J; Kim, H J; Kim, K C; Kim, S K; Kwon, Y; Panasyuk, M Y; Panov, A; Price, B; Samsonov, G; Schmidt, W K H; Sen, M; Seo, E S; Sina, R; Sokolskaya, N; Stewart, M; Voronin, A; Wagner, D; Wang, J Z; Wefel, J P; Wu, J; Zatsepin, V

    2005-01-01

    The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic-ray elemental spectra measurements from 50 GeV to 100 TeV for nuclei from hydrogen to iron. These measurements are expected to provide information about some of the most fundamental questions in astroparticle physics today. ATIC's design centers on an 18 radiation length (X0) deep bismuth germanate (BGO) calorimeter, preceded by a 0.75λint graphite target. In September 1999, the ATIC detector was exposed to high-energy beams at CERN's SPS accelerator within the framework of the development program for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). In December 2000–January 2001 and again in December 2002–January 2003, ATIC flew on the first two of a series of long-duration balloon (LDB) flights from McMurdo Station, Antarctica. We present here results from the 1999 beam tests, including energy resolutions for electrons and protons at several beam energies from 100 to 375 G...

  19. Molecular beam simulation of planetary atmospheric entry - Some recent results.

    Science.gov (United States)

    French, J. B.; Reid, N. M.; Nier, A. O.; Hayden, J. L.

    1972-01-01

    Progress is reported in the development of molecular beam techniques to simulate entry into planetary atmospheres. Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of a mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of this simulation technique are discussed, and it is demonstrated that even with certain inadequacies much information useful to the ion source design was obtained. Particularly, it is shown that an open-cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen.

  20. Successful beam tests for ALICE Transition Radiation Detector

    CERN Multimedia

    2002-01-01

    Another round of beam tests of prototypes for the Transition Radiation Detector (TRD) for ALICE has been completed and there are already some good results. Mass production of the components of the detector will start early next year.   Top view of the setup for the Transition Radiation Detector prototype tests at CERN.On the left, can be seen the full-scale TRD prototype together with four smaller versions. These are busy days for the TRD (Transition Radiation Detector) team of ALICE. Twenty people - mainly from Germany, but also from Russia and Japan - were working hard during the beam tests this autumn at CERN to assess the performance of their detector prototypes. Analysis of the data shows that the TRD can achieve the desired physics goal even for the highest conceivable multiplicities in lead-lead collisions at the LHC. In its final configuration in the ALICE experiment, the TRD will greatly help in identifying high-momentum electrons, which are 'needles in a haystack' that consists mostly of...

  1. First Results for the Beam Commissioning of the CERN Multi-Turn Extraction

    CERN Document Server

    Gilardoni, S; Benedetto, E; Bohl, T; Cettour Cave, S; Cornelis, K; Damerau, H; Follin, F; Fowler, T; Franchi, A; Freyermuth, P; Genoud, H; Giachino, R; Giovannozzi, M; hancock, S; Le Borgne, Y; Manglunki, D; Métral, G; Pereira, L; Ridewood, J; Riva, Y; Schokker, M; Sermeus, L; Steerenberg, R; Vandorpe, B; Wenninger, J

    2010-01-01

    The Multi-Turn Extraction (MTE), a new type of extraction based on beam trapping inside stable islands in horizontal phase space, has been commissioned during the 2008 run of the CERN Proton Synchrotron. Both singleand multi-bunch beams with a total intensity up to 1.4 1013 protons have been extracted with efficiencies up to 98%. Furthermore, injection tests in the CERN Super Proton Synchrotron were performed, with the beam then accelerated and extracted to produce neutrinos for the CERN Neutrino-to-Gran Sasso experiments. The results of the extensive measurement campaign are presented and discussed in detail.

  2. In Beam Tests of Implanted Helium Targets

    CERN Document Server

    McDonald, J E; Ahmed, M W; Blackston, M A; Delbar, T; Gai, M; Kading, T J; Parpottas, Y; Perdue, B A; Prior, R M; Rubin, D A; Spraker, M C; Yeomans, J D; Weissman, L; Weller, H R; Delbar, Th.; Conn, LNS/U; Duke, TUNL/

    2006-01-01

    Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. Helium implantation into the very thin (approximately 80-100 ug/cm^2) aluminum foils failed to produce useful targets (with only approximately 10% of the helium retained) due to an under estimation of the range by the code SRIM. The range of low energy helium in aluminum predicted by Northcliffe and Shilling and the NIST online tabulation are observed on the other hand to over estimate the range of low energy helium ions in aluminum. An attempt to increase the amount of helium by implanting a second deeper layer was also carried out, but it did not significantly increase the helium content beyond the blistering limit (ap...

  3. Plasma lens experiments at the Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, B. [California Univ., Los Angeles, CA (United States)]|[Lawrence Berkeley Lab., CA (United States); Chattopadhyay, S. [Lawrence Berkeley Lab., CA (United States); Chen, P. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)] [and others

    1993-04-01

    We intend to carry out a series of plasma lens experiments at the Final Focus Test Beam facility at SLAC. These experiments will be the first to study the focusing of particle beams by plasma focusing devices in the parameter regime of interest for high energy colliders, and is expected to lead to plasma lens designs capable of unprecedented spot sizes. Plasma focusing of positron beams will be attempted for the first time. We will study the effects of lens aberrations due to various lens imperfections. Several approaches will be applied to create the plasma required including laser ionization and beam ionization of a working gas. At an increased bunch population of 2.5 {times} 10{sup 10}, tunneling ionization of a gas target by an electron beam -- an effect which has never been observed before -- should be significant. The compactness of our device should prove to be of interest for applications at the SLC and the next generation linear colliders.

  4. FEM simulation of static loading test of the Omega beam

    Science.gov (United States)

    Bílý, Petr; Kohoutková, Alena; Jedlinský, Petr

    2017-09-01

    The paper deals with a FEM simulation of static loading test of the Omega beam. Omega beam is a precast prestressed high-performance concrete element with the shape of Greek letter omega. Omega beam was designed as a self-supporting permanent formwork member for construction of girder bridges. FEM program ATENA Science was exploited for simulation of load-bearing test of the beam. The numerical model was calibrated using the data from both static loading test and tests of material properties. Comparison of load-displacement diagrams obtained from the experiment and the model was conducted. Development of cracks and crack patterns were compared. Very good agreement of experimental data and the FEM model was reached. The calibrated model can be used for design of optimized Omega beams in the future without the need of expensive loading tests. The calibrated material model can be also exploited in other types of FEM analyses of bridges constructed with the use of Omega beams, such as limit state analysis, optimization of shear connectors, prediction of long-term deflections or prediction of crack development.

  5. Static and dynamic testing of a damaged post tensioned concrete beam

    Directory of Open Access Journals (Sweden)

    Limongelli M.P.

    2015-01-01

    Full Text Available In this paper are reported the results of an experimental campaign carried out on a post tensioned concrete beam with the aim of investigating the possibility to detect early warning signs of deterioration basing on static and/or dynamic tests. The beam was tested in several configurations aimed to reproduce several different phases of the ‘life’ of the beam: the original undamaged state, increasing loss of tension in the post tensioning cables, a strengthening intervention carried out by means of a second tension cable, formation of further cracks on the strengthened beam. Responses of the beam were measured by an extensive set of instruments consisting of accelerometers, inclinometers, displacement transducers, strain gauges and optical fibres. The paper discusses the tests program and the dynamic characterization of the beam in the different damage scenarios. The modal properties of the beam in the different phases were recovered basing on the responses recorded on the beam during sine-sweep and impact hammer tests. The variation of the first modal frequency was studied to investigate the sensitivity of this parameter to both the cracking of the concrete section and the tension in the cables and also to compare results given by different types of experimental tests.

  6. Testing long range beam-beam compensation for the LHC luminosity upgrade

    CERN Document Server

    Rijoff, Tatiana; Caracciolo, Sergio

    The performance of the Large Hadron Collider (LHC) at CERN and its minimum crossing angle are limited by long-range beam-beam collisions. A wire compensators can mitigate part of the long-range effects and may allow for smaller crossing angles, or higher beam intensity. A prototype long-range wire compensator should be installed in the LHC by 2014/15. The originally reserved position for the wire compensator (named BBC) seems not available in this first step, we need so to test other possibilities. The performed tests consider various longitudinal and transverse locations, different wire shapes, different optics configuration and trying several crossing angles between the beam. Simulation are done with the weak-strong code BBtrack developed by U. Dorda. New postprocessing tools were used to analyse tune footprints and particle stability In particular for particle stability was implemented a new method for the Lyapunov coefficient calculation.

  7. Testing beam-induced quench levels of LHC superconducting magnets

    CERN Document Server

    Auchmann, B.; Bednarek, M.; Bellodi, G.; Bracco, C.; Bruce, R.; Cerutti, F.; Chetvertkova, V.; Dehning, B.; Granieri, P.P.; Hofle, W.; Holzer, E.B.; Lechner, A.; Del Busto, E. Nebot; Priebe, A.; Redaelli, S.; Salvachua, B.; Sapinski, M.; Schmidt, R.; Shetty, N.; Skordis, E.; Solfaroli, M.; Steckert, J.; Valuch, D.; Verweij, A.; Wenninger, J.; Wollmann, D.; Zerlauth, M.

    2015-06-25

    In the years 2009-2013 the Large Hadron Collider (LHC) has been operated with the top beam energies of 3.5 TeV and 4 TeV per proton (from 2012) instead of the nominal 7 TeV. The currents in the superconducting magnets were reduced accordingly. To date only seventeen beam-induced quenches have occurred; eight of them during specially designed quench tests, the others during injection. There has not been a single beam- induced quench during normal collider operation with stored beam. The conditions, however, are expected to become much more challenging after the long LHC shutdown. The magnets will be operating at near nominal currents, and in the presence of high energy and high intensity beams with a stored energy of up to 362 MJ per beam. In this paper we summarize our efforts to understand the quench levels of LHC superconducting magnets. We describe beam-loss events and dedicated experiments with beam, as well as the simulation methods used to reproduce the observable signals. The simulated energy depositio...

  8. Test of the BEXE autocorrelator circuit at the CLIC laser beam

    CERN Document Server

    Aulenbacher, K; Cornali, R; Manarin, A; Rossa, E; Schmickler, Hermann; Voors, G; CERN. Geneva. SPS and LEP Division

    1997-01-01

    This device allows the measurement of the bunch length of a photon bunch by autocorrelation. The detector works in a very large range from X-rays to Infrared. This report describes the laser beam test and the resulting calibration.

  9. Initial commissioning results with the NSCL Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, S.; Kittimanapun, K.; Lapierre, A.; Leitner, D.; Ottarson, J.; Portillo, M. [National Superconducting Cyclotron Laboratory, NSCL, Michigan State University, East Lansing, Michigan 48824 (United States); Bollen, G. [National Superconducting Cyclotron Laboratory, NSCL, Michigan State University, East Lansing, Michigan 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824 (United States); Lopez-Urrutia, J. R. Crespo [Max-Planck Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Kester, O. [GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany)

    2012-02-15

    The ReA reaccelerator is being added to the National Superconducting Cyclotron Laboratory (NSCL) fragmentation facility in order to provide exotic rare-isotope beams, not available at the Isotope Separation On-Line facilities, in the several-MeV/u energy range. The first stage of the NSCL reaccelerator complex, consisting of an EBIT charge breeder, a room-temperature radiofrequency quadrupole (RFQ) accelerator, and superconducting linear accelerator modules, has been completed and is being put into operation. Commissioning of the EBIT has started by extracting charge-bred residual gas ions, ions created from a Ne gas jet directed across the EBIT's electron beam and ions captured from an external test ion source. Charge-bred ions from the Ne gas jet have been extracted as a pulse and accelerated through the RFQ and the two cryomodules.

  10. Beam position determination for the Test Storage Ring

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Peter

    1987-01-01

    The Test Storage Ring (TSR) for heavy ions, currently under design and construction at the Max Planck Institute for Nuclear Physics in Heidelberg, requires an extensive beam diagnostics system in order to enable it to operate without friction. This thesis concerns the beam position determination sub-system of this diagnostics system which is intended to determine the beam center of gravity of a bunched beam inside the cross section of the beam tube in a non-destructive manner. An electrostatic pickup is used to sense the location of the beam; the mode of operation of this device will be explained in detail. The signals go to a preamplifier from where they are then sent via a multiplex system to the measuring unit. This point also represents the interface to the computer system that controls the TSR. The prototype developed here was tested with the aid of a particle beam, as well as with other measurement methods. Resolutions of better than 1 mm about the center have been measured. In order to achieve or even improve such resolutions later in actual operation, it is possible to determine the properties of the preamplifiers with the aid of calibration signals and to take these into account in the course of the signal evaluation in the computer. The differences between the individual electrodes of a given pickup must also be compensated. These procedures and their associated electronic circuits are also described in this paper.

  11. The progress of funnelling gun high voltage condition and beam test

    Energy Technology Data Exchange (ETDEWEB)

    Wang, E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gassner, D. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Lambiase, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Meng, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rahman, O. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pikin, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rao, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sheehy, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Skaritka, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pietz, J. [Transfer Engineering and Manufacturing, Inc., Fremont, CA (United States); Ackeret, M. [Transfer Engineering and Manufacturing, Inc., Fremont, CA (United States); Yeckel, C. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Miller, R. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Dobrin, E. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Thompson, K. [Thompson, Stangenes Industries, Palo Alto, CA (United States)

    2015-05-03

    A prototype of a high average current polarized electron funneling gun as an eRHIC injector has been built at BNL. The gun was assembled and tested at Stangenes Incorporated. Two beams were generated from two GaAs photocathodes and combined by a switched combiner field. We observed the combined beams on a YAG crystal and measured the photocurrent by a Faraday cup. The gun has been shipped to Stony Brook University and is being tested there. In this paper we will describe the major components of the gun and recent beam test results. High voltage conditioning is discussed as well.

  12. Experimental results of beryllium exposed to intense high energy proton beam pulses

    Energy Technology Data Exchange (ETDEWEB)

    Ammigan, K. [Fermilab; Hartsell, B. [Fermilab; Hurh, P. [Fermilab; Zwaska, R. [Fermilab; Butcher, M. [CERN; Guinchard, M. [CERN; Calviani, M. [CERN; Losito, R. [CERN; Roberts, S. [Culham Lab; Kuksenko, V. [Oxford U.; Atherton, A. [Rutherford; Caretta, O. [Rutherford; Davenne, T. [Rutherford; Densham, C. [Rutherford; Fitton, M. [Rutherford; Loveridge, J. [Rutherford; O' Dell, J. [Rutherford

    2017-02-10

    Beryllium is extensively used in various accelerator beam lines and target facilities as a material for beam windows, and to a lesser extent, as secondary particle production targets. With increasing beam intensities of future accelerator facilities, it is critical to understand the response of beryllium under extreme conditions to reliably operate these components as well as avoid compromising particle production efficiency by limiting beam parameters. As a result, an exploratory experiment at CERN’s HiRadMat facility was carried out to take advantage of the test facility’s tunable high intensity proton beam to probe and investigate the damage mechanisms of several beryllium grades. The test matrix consisted of multiple arrays of thin discs of varying thicknesses as well as cylinders, each exposed to increasing beam intensities. This paper outlines the experimental measurements, as well as findings from Post-Irradiation-Examination (PIE) work where different imaging techniques were used to analyze and compare surface evolution and microstructural response of the test matrix specimens.

  13. TEST BEAM COORDINATION: Major upgrade of the ATLAS Test Beam network infrastructure

    CERN Multimedia

    Di Girolamo, B; Pasqualucci, E

    Based on the positive experience gained last year by the Muon group with the adoption of a completely isolated private network for the data acquisition, already last year for the 2002 Combined Pixel-Tilecal-Muon Test Beam, we adopted the private network solution. The main advantage of the isolation from the common CERN network infrastructure is the complete independence from possible problems that could affect the network in the area, intended to serve many other users, and the possibility to have a completely independent management of the IP addresses assignment. Moreover the presence of a firewall in the private network allows a better protection against possible external hackers, allowing users to transparently access the external word. A Fast Ethernet network has been set up as a control network. It relies on a backbone 24-port Fast Ethernet switch on which, in a tree structure, are connected several smaller switches dedicated to each sub-detector. In this way each sub-detector produces its own traffic...

  14. Modified Mode-I Cracked Sandwich Beam (CSB) Fracture Test

    Science.gov (United States)

    Smith, S. A.; Shivakumar, K. N.

    2001-01-01

    Five composite sandwich panels were fabricated using vacuum assisted resin transfer molding (VARTM). Four of these panels had E-glass/vinylester facesheets and one had carbon/epoxy facesheets. The sandwich panels had different density PVC foam cores. The four E-glass panels had core densities of 80, 100, 130, 200 kg/cu m. The sandwich with carbon/epoxy 3 facesheets had a core with density of 100 kg/cu m. Fracture tests were conducted using a modified Cracked Sandwich Beam (CSB) test configuration. Load displacement curves were obtained for loading and unloading of the specimens during crack growth. Various increments of crack growth were monitored. Critical Strain Energy Release Rates (SERR) were determined from the tests using the area method. The critical values of SERR can be considered the fracture toughness of the sandwich material. The fracture toughness ranged 367 J/sq m to 1350 J/sq m over the range of core densities. These results are compared to the Mode-I fracture toughness of the PVC foam core materials and values obtained for foam-cored sandwiches using the TSD specimen. Finite-element analyses (FEA) were performed for the test configuration and Strain Energy Release Rates were calculated using the Virtual Crack Closure Technique (VCCT). The SERR values determined from the FEA were scaled to the fracture loads, or critical loads, obtained from the modified CSB tests. These critical loads were in close agreement with the test values.

  15. Development and Beam Tests of an Automatic Algorithm for Alignment of LHC Collimators with Embedded BPMs

    CERN Document Server

    Valentino, G; Gasior, M; Mirarchi, D; Nosych, A A; Redaelli, S; Salvachua, B; Assmann, R W; Sammut, N

    2013-01-01

    Collimators with embedded Beam Position Monitor (BPM) buttons will be installed in the LHC during the upcoming long shutdown period. During the subsequent operation, the BPMs will allow the collimator jaws to be kept centered around the beam trajectory. In this manner, the best possible beam cleaning efficiency and machine protection can be provided at unprecedented higher beam energies and intensities. A collimator alignment algorithm is proposed to center the jaws automatically around the beam. The algorithm is based on successive approximation, as the BPM measurements are affected by non-linearities, which vary with the distance between opposite buttons, as well as the difference between the beam and the jaw centers. The successful test results, as well as some considerations for eventual operation in the LHC are also presented.

  16. Testing fundamental symmetries using radioactive ion beams at ...

    Indian Academy of Sciences (India)

    The ISAC Facility at TRIUMF, Canada's national laboratory for particle and nuclear physics, provides rare isotope beams for a diverse research program. In this paper we summarize some recent experimental developments at TRIUMF pertaining to fundamental symmetry tests. These tests use the atomic nucleus as a probe ...

  17. Tests of Local Hadron Calibration approaches in ATLAS Combined Beam Tests

    CERN Document Server

    Pospelov, G; The ATLAS collaboration

    2010-01-01

    The three Atlas calorimeter systems in the region of the forward crack at |eta| = 3.2 in the nominal Atlas setup and a typical section of the two barrel calorimeters at |eta| = 0.45 of Atlas have been exposed to combined beam tests with single electrons and pions. Detailed shower shape studies of electrons and pions with comparisons to various Geant4 based simulations utilizing different physics lists are presented for the endcap testbeam. The local hadronic calibration approach as used in the full Atlas setup has been applied to the endcap test beam data. An extension of it using layer correlations has been tested on the barrel test beam data. Both methods utilize modular correction steps based on shower shape variables to correct for invisible energy inside the reconstructed clusters in the calorimeters (compensation) and for lost energy deposits outside of the reconstructed clusters (dead material and out-of-cluster deposits). Results for both methods and comparisons to MC simulations are presented.

  18. Tests of a particle flow algorithm with CALICE test beam data

    CERN Document Server

    ,; CALICE Collaboration

    2011-01-01

    The studies presented in this paper provide a first experimental test of the Particle Flow Algorithm (PFA) concept using data recorded in high granularity calorimeters. Pairs of overlaid pion showers from CALICE 2007 test beam data are reconstructed by the PandoraPFA program developed to implement PFA for a future lepton collider. Recovery of a neutral hadron's energy in the vicinity of a charged hadron is studied. The impact of the two overlapping hadron showers on energy resolution is investigated. The dependence of the confusion error on the distance between a 10 GeV neutral hadron and a charged pion is derived for pion energies of 10 and 30 GeV which are representative of a 100 GeV jet. The comparison of these test beam data results with Monte Carlo simulation is done for various hadron shower models within the GEANT4 framework. The results for simulated particles and for beam data are in good agreement thereby providing support for previous simulation studies of the power of Particle Flow Calorimetry at ...

  19. Test Beam Data Analysis for a Timepix3 Readout Chip

    CERN Document Server

    Williams, Morag

    2016-01-01

    The vertex and tracker detector R&D for a future linear collider (CLICdp) aims at developing new silicon sensor technologies. The EP-LCD group has been helping develop a novel pixel detector chip called the Timepix3 with a very thick active silicon layer (675 μm). This thick detector can be used to reconstruct the track incidence angle using the charge drift-time information. To evaluate the principle, test beam data was taken in October 2015 and June 2016 with the Timepix3 at various angles to the beam. The data was analysed to evaluate the sensors performance in calculating the track incidence angle. The device angle was determined using three methods: the first using the cluster size information, secondly using the timing information, and finally using a multivariate analysis technique. The timing method proved the principle of the Timepix3 track angle measurements but the MVA method was found to give much better results, especially for smaller angles, than the other two methods and requires fewer cal...

  20. Status of an automatic Beam Steering for the CLIC Test Facility 3

    CERN Document Server

    Adli, E; Dabrowski, A; Schulte, D; Shaker, SH; Skowronski, P; Tecker, F; Tomás, R

    2008-01-01

    An automatic beam steering application for CTF 3 is being designed in order to automatize operation of the machine, as well as providing a test-bed for advanced steering algorithms for CLIC. Beam-based correction including dispersion free steering have been investigated. An approach based on a PLACET on-line model has been tested. This paper gives an overview of the current status and the achieved results of the CTF3 automatic steering.

  1. Overall Buckling and Wringkling of Debonded Sandwich Beams: Finite Element and Experimental Results

    Directory of Open Access Journals (Sweden)

    Bambang K. Hadi

    2006-05-01

    Full Text Available Overall buckling and wrinkling of debonded sandwich beams under compressive loads were analyzed by both finite element and experimental methods. In the finite element method, a quarter and a half models of the specimens were analyzed. It shows that a quarter model is not adequate to analyze buckling of debonded sandwich beams, since it will disregard overall buckling mode that may occur in sandwich beams having compressive loads. At least a half model should be used to analyze buckling of sandwich beams. A finite element program UNA was used extensively to analyze the buckling loads. Experimental buckling of sandwich beams was carried out using a compression testing machine. Two LVDTs were used to measure deflections of the specimen during experimental loading. The loads were measured using load cells available in the machine. Specimens having core thickness of 45 and 75 mm were tested to represent overall and wrinkling modes respectively. The delamination lengths were 20, 60 and 80 mm, which represent 10, 30 and 40% of the beam length. The results show that the differences between experimental and finite element methods were less than 10%. Both overall buckling and wrinkling modes were shown in these specimens.

  2. The trigger system of the first CMS tracker beam tests

    Energy Technology Data Exchange (ETDEWEB)

    Schwaller, B.; Drouhin, F.; Pallares, A.; Fontaine, J.C.; Benhammou, Y.; Charles, F.; Huss, D. [Univ. de Haute Alsace, Mulhouse (France). Groupe de Recherche en Physique des Hautes Energies; Hoffmann, C. [Inst. de Recherches Subatomiques, Strasbourg (France). Unite d`Electronique EXperimentale, Strasbourg (France)

    1998-10-01

    The trigger for the first compact muon solenoid (CMS) tracking beam tests is a dedicated system for analog multiplexed front-end electronics. With this first generation of electronics dedicated to CMS tracker detectors, some new specific development was necessary to read it with a multicrate distributed Data AcQuisition (DAQ) system. The goal of this development was to reach a high scalability of experiment subsystems and a good robustness for test beams. Each subsystem had to be independent from the others, both from the hardware and software point of view. Remote control software for this system as well as further monitoring facilities were the required functions of the trigger system.

  3. Design and construction of a prototype of a flat top beam interferometer and initial tests

    Energy Technology Data Exchange (ETDEWEB)

    Agresti, J [University of Pisa, Largo Pontecorvo 3, Pisa (Italy); D' Ambrosio, E [LIGO Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); DeSalvo, R [LIGO Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Forest, D [Laboratoire des Materiaux Avances, 22 Bd.Niels Bohr, Villeurbane (France); Lagrange, B [Laboratoire des Materiaux Avances, 22 Bd.Niels Bohr, Villeurbane (France); Mackowski, J M [Laboratoire des Materiaux Avances, 22 Bd.Niels Bohr, Villeurbane (France); Michel, C [Laboratoire des Materiaux Avances, 22 Bd.Niels Bohr, Villeurbane (France); Montorio, J L [Laboratoire des Materiaux Avances, 22 Bd.Niels Bohr, Villeurbane (France); Morgado, N [Laboratoire des Materiaux Avances, 22 Bd.Niels Bohr, Villeurbane (France); Pinard, L [Laboratoire des Materiaux Avances, 22 Bd.Niels Bohr, Villeurbane (France); Remillieux, A [Laboratoire des Materiaux Avances, 22 Bd.Niels Bohr, Villeurbane (France); Simoni, B [University of Pisa, Largo Pontecorvo 3, Pisa (Italy); Tarallo, M [University of Pisa, Largo Pontecorvo 3, Pisa (Italy); Willems, P [LIGO Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States)

    2006-03-02

    A non-Gaussian, flat-top laser beam profile, also called Mesa Beam Profile, supported by non spherical mirrors known as Mexican Hat (MH) mirrors, has been proposed as a way to depress the mirror thermal noise and thus improve the sensitivity of future interferometric Gravitational Wave detectors, including Advanced LIGO. Non-Gaussian beam configurations have never been tested before hence the main motivation of this project is to demonstrate the feasibility of this new concept. A 7m rigid suspended Fabry-Perot (FP) cavity which can support a scaled version of a Mesa beam applicable to the LIGO interferometers has been developed. The FP cavity prototype is being designed to prove the feasibility of actual MH mirror profiles, determine whether a MH mirror cavity is capable of transforming an incoming Gaussian beam into a flat top beam profile, study the effects of unavoidable mirror imperfections on the resulting beam profile and gauge the difficulties associated with locking and maintaining the alignment of such an optical cavity. We present the design of the experimental apparatus and simulations comparing Gaussian and Mesa beams performed both with ideal and current (measured) mirror profiles. An overview of the technique used to manufacture this kind of mirror and initial results showing Mesa beam properties are presented.

  4. LLRF beam results on the first year of ELENA’s commissioning with beam

    CERN Document Server

    Angoletta, Maria Elena; Molendijk, John; Sanchez Quesada, Jorge; CERN. Geneva. ATS Department

    2018-01-01

    CERN’s Extra Low ENergy Antiproton (ELENA) ring’s commissioning with beam started in earnest in March 2017. Ions from an H- source were injected in ELENA at low energy, although in a degraded way (lower voltage and intensity than planned) and with not constant reproducibility of the injection. From August 2017 onwards antiprotons from the AD were also injected in ELENA at high energy for up to three, weekly MD session. The 2017 ELENA commissioning run stopped on December 1st to allow the installation of the electron cooler. This note gives an overview of the successful operation carried out by the ELENA Low-Level RF (LLRF) during the first year of ELENA commissioning and of the main beam results obtained. Operation with H- ions and with antiprotons are considered, together with different operational settings and problems encountered. Hints on future deployment and commissioning steps are also provided.

  5. Propagation of low-quality laser beams in turbulent air: new fast simulation methods and experimental results

    Science.gov (United States)

    Hall, Thomas; Spindler, Gerhard; Becker, Peter; Grünewald, Karin; Pargmann, Carsten; Duschek, Frank

    2017-11-01

    Novel inherently fast methods basing upon fundamental Gaussian modes are presented to numerically simulate the propagation behavior of a low-quality laser beam, i.e., a beam characterized by a high quality factor M^2, in turbulent air. Actually, for a given initial diameter, beam wandering and spread at the target position is calculated. Test results are checked against respective simulations using higher-order mode beams having clearly defined quality factors and nearly perfect agreement is demonstrated. Experiments performed on the German Aerospace Center (DLR) laser test range at Lampoldshausen near Stuttgart satisfactorily accord with the predictions of the proposed simulation techniques.

  6. RSG Deployment Case Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Owsley, Stanley L.; Dodson, Michael G.; Hatchell, Brian K.; Seim, Thomas A.; Alexander, David L.; Hawthorne, Woodrow T.

    2005-09-01

    The RSG deployment case design is centered on taking the RSG system and producing a transport case that houses the RSG in a safe and controlled manner for transport. The transport case was driven by two conflicting constraints, first that the case be as light as possible, and second that it meet a stringent list of Military Specified requirements. The design team worked to extract every bit of weight from the design while striving to meet the rigorous Mil-Spec constraints. In the end compromises were made primarily on the specification side to control the overall weight of the transport case. This report outlines the case testing results.

  7. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  8. QCD tests with SLD and polarized beams

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, M.G. [Univ. of Massachusetts, Amherst, MA (United States)

    1994-12-01

    The author presents a measurement of the strong coupling {alpha}{sub s} derived from multijet rates using data collected by the SLD experiment at SLAC and find that {alpha}{sub s}(M{sub Z}{sup 2}) = 0.118 {+-} 0.002(stat.) {+-} 0.003(syst.) {+-} 0.010(theory). He presents tests of the flavor independence of strong interactions via preliminary measurements of the ratios {alpha}{sub s}(b)/{alpha}{sub s}(udsc) and {alpha}{sub s}(uds)/{alpha}{sub s}(bc). In addition, the group has measured the difference in charged particle multiplicity between Z{sup 0} {yields} b{bar b} and Z{sup 0} {yields} u{bar u}, d{bar d}, s{bar s} events, and find that it supports the prediction of perturbative QCD that the multiplicity difference be independent of center-of-mass energy. Finally, the group has made a preliminary study of jet polarization using the jet handedness technique.

  9. Spectrometry in the Test Beam Line at CTF3

    CERN Document Server

    Olvegaard, Maja; Chritin, N; Dabrowski, A; Dallocchio, A; Doebert, S; Lefevre, T; Adli, E

    2010-01-01

    The CLIC study is based on the so-called two-beam acceleration concept and one of the main goals of the CLIC Test Facility 3 is to demonstrate the efficiency of the CLIC RF power production scheme. As part of this facility a Test Beam Line (TBL), presently under commissioning, is a small-scale version of a CLIC decelerator. To perform as expected the beam line must show efficient and stable RF power production over 16 consecutive decelerating structures. As the high intensity electron beam is decelerated its energy spread grows by up to 60 %. A novel segmented beam dump for time resolved energy measurements has been designed to match the requirements of the TBL. As a complement, a diffusive OTR screen is also installed in the same spectrometer line. The combination of these two devices will provide both a high spatial resolution measurement of both the energy and energy spread and a measurement with a few nanoseconds time response. This paper describes the design of the new segmented dump and presents the res...

  10. Fermilab Test Beam Facility Annual Report. FY 2014

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States). et al.

    2015-01-01

    Fermilab Test Beam Facility (FTBF) operations are summarized for FY 2014. It is one of a series of publications intended to gather information in one place. In this case, the information concerns the individual experiments that ran at FTBF. Each experiment section was prepared by the relevant authors, and was edited for inclusion in this summary.

  11. Planck 2013 results. VII. HFI time response and beams

    DEFF Research Database (Denmark)

    Planck Collaboration,; Ade, P. A. R.; Aghanim, N.

    2013-01-01

    This paper characterizes the effective beams, the effective beam window functions (EBWF) and the associated errors for the Planck High Frequency Instrument (HFI) detectors. The effective beam is the angular response including the effect of the optics, detectors, data processing and the scan strat...

  12. PSB LLRF renovation: Initial beam tests of the new digital beam control system

    CERN Document Server

    Angoletta, ME; Butterworth, A; Findlay, A; Pedersen, F; CERN. Geneva. BE Department

    2009-01-01

    The beam control renovation project for CERN’s PS Booster (PSB) was started in autumn 2008. Its aim is to equip all four PSB rings with modern digital beam control systems, characterised by fully-PPM parameters and complete remote control. Additionally, all intermediate and input/output signals are to be remotely acquired in a digital way and in full PPM fashion, and displayed via the Oasis application program. The same digital technology concepts have already been successfully applied to the LEIR beam control system, which has acted as a pilot project for the whole PS Complex renovation project. This new technology allows a very flexible performance and can improve the system maintainability by becoming the standard for the PS Complex beam controls. This note details the first step in the PSB consolidation project, namely the beam control prototype tests carried out on PSB ring 4 in October and November 2008. Both C02 and C04 RF system have been successfully controlled; bunch splitting and extraction synch...

  13. The Overall Research Results of Prestressed I-beams Made of Ultra-high Performance Concrete

    Science.gov (United States)

    Tej, P.; Kolísko, J.; Kněž, P.; Čech, J.

    2017-09-01

    The design process of short-term and long-term loading of prestressed I-beams made of ultra-high performance concrete (UHPC) and the overall research results are presented in this article. The prestressed I-beams are intended and designed to replace steel HEB beams mainly in the construction of railway bridges with fully concreted height of the beams. These types of structures have the advantage of a low construction height. The prestressed I-beams were made of UHPC with dispersed steel fibres and are reinforced by prestressing cables in the bottom flange. Two specimens of 9 m span, three specimens of 7 m span and two specimens of 12 m span were made for the short-term loading. For the purpose of the long-term loading, two specimens of 12 m span were made and subsequently loaded for 450 days. All specimens were tested in four-point bending tests in the laboratory. The article presents also comparison of results of the experiments with computer simulations.

  14. Last Stand-alone Beam Test of the Hadronic End-cap Calorimeter (HEC) Finished.

    CERN Multimedia

    Oberlack, H

    One quarter of all 134 HEC modules are tested with electron, pion and muon beams: two "partial HEC wheels", three HEC1 modules and three HEC2 modules, are used in a standard setup using the HEC cryostat in the H6 beam line. The picture shows a view of the set-up in the cryostat during the installation. MC results show that in this setup the energy leakage is well under control - well below 5 %. In addition, the other three quarters of modules are tested in technical cold tests. Using calibration signals, a detailed test of the cabling, cold electronics, crosstalk and noise performance is being done. The beam tests started with four prototype modules per run in '97, when technological optimization was still the key issue. From '98 onwards, modules of the "module 0" type have been tested, typically in two run periods per year. Finally in '99 the series production has started, with first beam test of series modules in 2000. Since then 57 series modules have been cold tested, 24 of them actually in beam tests. T...

  15. FIRST RESULTS FROM OEDOTENSIOMETRIC TESTS

    Directory of Open Access Journals (Sweden)

    Luigi Cavazza

    2008-09-01

    Full Text Available An oedotensiometer was used to examine to examine the behaviour of sieved sample of a swelling soil (a vertisol as well as of the same soils treated with solution of Na+ + Ca2+ to simulate the soil changes from excessive irrigation with brackish water. The oedometer test consisted in an infiltration of water from below through a ceramic porous plate at a feeding pressure of +10 cm water and successive drainage under a depression mostly of -112 cm of water. The rate of water entry as well as the swelling rate of the sample were monitored. Preliminary considerations regards the domains in which the shrinkage curve of a swelling soil is subdivided and make hypothesis on the swelling process expected when the infiltration from below of the sample is applied. The results support the hypothesis that when the water pressure is applied some water enters rather rapidly in the larger structural pores and is followed later by the swelling in the smaller pores, responsible for the basic domain. This first conclusion demonstrates that the assumption of a simultaneous movement of solid and liquid components in the sample, which is the base of most theoretical developments for swelling soils, cannot be accepted for the tested samples. Some cases with water clogging on the sample surface confirm a late final swelling of the soil and permitted to evaluate the hydraulic conductivity of the swollen soil. These manifestations are more evident in sodicated soils. The loading of the sample reduces the swelling of the sample and seems to reduce its permeability. The reduction of the feeding water pressure further reduces the sample swelling. The draining process from saturated soil sample shows that most of the process occurs in the large pores of the structural domain. This gives the possibility to evaluate the water diffusivity coefficient for the structural domain of the sample. In draining the soil with the highest sodication there was a variation of soil volume

  16. Numerical analyses and laboratory testing of concrete composite T-shaped beams without interface adhesion

    Science.gov (United States)

    Jabłoński, Łukasz

    2018-01-01

    Laboratory tests of concrete composite concrete T-shaped beams with variously arranged interface were performed. In the particular series the interface between concrete parts was reinforced or non-reinforced. Additionally the interface conditions varied as follows: existence of adhesion in the interface, adhesion partly broken using chemical agent and adhesion completely broken with PVE membrane put in the interface. The paper presents the compiled results of all tests and the first stage of FEM analysis concerning the series of beams, where the adhesion was broken. Results of numerical analysis are compared with the crack pattern observed during tests.

  17. Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams

    Science.gov (United States)

    Dong, Hongying; Cao, Wanlin; Wu, Haipeng; Zhang, Jianwei; Xu, Fangfang

    2013-12-01

    A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements — the CFST columns and SP deep beams — to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.

  18. Data Analysis and Simulation for the RICH Upgrade Test Beam

    CERN Document Server

    Lalanne, Louis-Alexandre

    2017-01-01

    The LHCb experiment is one of the four particles physics experiments collecting data at the Large Hadron Collider. One of its key detector components is the Ring-Imaging Cherenkov (RICH) system. This provides charged particle identification over a wide momentum range, from 2–100 GeV/c. In order to increase the readout frequency from 1MHz to 40MHz RICH detectors will be upgrade in 2020. Prototypes are designed and tested by the RICH upgrade group of CERN. A full GEANT4 simulation have been programmed to reproduce the experimental test beam set-up and to produce MonteCarlo data. Those data have been compared to data from the test beam in order to study and compared the photon yield and the Cherenkov angle resolution of the most recent version of RICH.

  19. Results from the OPERA experiment at the CNGS beam

    Directory of Open Access Journals (Sweden)

    Mauri N.

    2017-01-01

    Full Text Available The OPERA experiment at the Gran Sasso underground laboratory was designed to study vμ → vτ oscillations in appearance mode in the CNGS neutrino beam. Five vτ candidate events have been observed, allowing to assess the discovery of vμ → vτ transitions in the atmospheric sector with a significance of 5.1σ. In this paper the vτ data analysis will be discussed, with emphasis on the background constraints obtained using dedicated data-driven control samples. Results on the search for vμ → vτ oscillations, on the search for sterile neutrino mixing and on the atmospheric muon charge ratio will also be presented.

  20. Chemical compatibility screening test results

    Energy Technology Data Exchange (ETDEWEB)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60{degrees}C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m{sup 2} for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals.

  1. Ultrasonic Transducer Irradiation Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Palmer, Joe [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Keller, Paul [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Montgomery, Robert [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chien, Hual-Te [Argonne National Lab. (ANL), Argonne, IL (United States); Kohse, Gordon [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States); Tittmann, Bernhard [Pennsylvania State Univ., University Park, PA (United States); Reinhardt, Brian [Pennsylvania State Univ., University Park, PA (United States); Rempe, Joy [Rempe and Associates, Idaho Falls, ID (United States)

    2015-02-01

    Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric

  2. Backsplash studies for the Scintillator Pad Detector of LHCb in a tagged-photon test beam

    CERN Document Server

    Garrido, L; Miquel, R; Peralta, D

    2002-01-01

    The Scintillator Pad Detector (SPD) of the LHCb experiment is part of the calorimeter system, positioned just before the preshower (PS), and is meant to separate photons and electrons at level 0 of the trigger. A tagged-photon test beam allowed to test in photon signals the SPD. These signals are mainly due to pair production inside the scintillator and to particles generated in the electromagnetic shower in the PS and in the electromagnetic calorimeter (backsplash). The observed results in a test beam experiment stress the low inefficiencies in e/gamma separation arising from backsplash.

  3. Fermilab Test Beam Facility Annual Report FY17

    Energy Technology Data Exchange (ETDEWEB)

    Rominsky, M. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Schmidt, E. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Rivera, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Uplegger, L. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Asaadi, J. [Univ. of Texas, Arlington, TX (United States); Raaf, J. L. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Freeman, J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Price, J. [Univ. of Liverpool (United Kingdom); Casey, B. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Ehrlich, R. [Univ. of Virginia, Charlottesville, VA (United States); Belmont, R. [Univ. of Colorado, Boulder, CO (United States); Boose, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Conners, M. [Georgia State Univ., Atlanta, GA (United States); Haggerty, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Hill, K. [Univ. of Colorado, Boulder, CO (United States); Hodges, A. [Georgia State Univ., Atlanta, GA (United States); Huang, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Kistenev, E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Lajoie, J. [Iowa State Univ., Ames, IA (United States); Mannel, E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Osborn, J. [Univ. of Michigan, Ann Arbor, MI (United States); Pontieri, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Purschke, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sarsour, M. [Georgia State Univ., Atlanta, GA (United States); Sen, A. [Iowa State Univ., Ames, IA (United States); Skoby, M. [Univ. of Michigan, Ann Arbor, MI (United States); Stoll, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Toldo, F. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ujvari, B. [Debrecen Univ., Debrecen (Hungary); Woody, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ronzhin, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Hanagaki, K. [High Energy Accelerator Research Organization (KEK), Tsukuba (Japan); Apresyan, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Bose, T. [Boston Univ., MA (United States); Canepa, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Demina, R. [Univ. of Rochester, NY (United States); Gershtein, Y. [Rutgers Univ., Piscataway, NJ (United States); Halkiadakis, E. [Rutgers Univ., Piscataway, NJ (United States); Haytmyradov, M. [Univ. of Iowa, Iowa City, IA (United States); Hazen, E. [Boston Univ., MA (United States); Hindrichs, O. [Univ. of Rochester, NY (United States); Korjenevski, S. [Univ. of Rochester, NY (United States); Nachtman, J. [Univ. of Iowa, Iowa City, IA (United States); Narain, M. [Brown Univ., Providence, RI (United States); Nash, K. [Rutgers Univ., Piscataway, NJ (United States); Onel, Y. [Univ. of Iowa, Iowa City, IA (United States); Osherson, M. [Rutgers Univ., Piscataway, NJ (United States); Rankin, D. [Boston Univ., MA (United States); Schneider, B. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Stone, B. [Rutgers Univ., Piscataway, NJ (United States); Metcalfe, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Benoit, M. [Univ. of Geneva (Switzerland); Vicente, M. [Univ. of Geneva (Switzerland); di Bello, F. [Univ. of Geneva (Switzerland); Cavallaro, E. [Univ. Autonoma de Barcelona (Spain); Chakanov, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Frizzell, D. [Univ. of Oklahoma, Norman, OK (United States); Kiehn, M. [Univ. of Geneva (Switzerland); Meng, L. [Univ. of Geneva (Switzerland); Miucci, A. [Univ. of Bern, Bern (Switzerland); Nodulman, L. [Argonne National Lab. (ANL), Argonne, IL (United States); Terzo, S. [Univ. Autonoma de Barcelona (Spain); Wang, Rui [Argonne National Lab. (ANL), Argonne, IL (United States); Weston, T. [Univ. of Oklahoma, Norman, OK (United States); Xie, Junqie [Argonne National Lab. (ANL), Argonne, IL (United States); Xu, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Zaffaroni, E. [Univ. of Geneva (Switzerland); Zhang, M. [Univ. of Illinois, Urbana, IL (United States); Argelles, C. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Axani, S. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Conrad, J. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Katori, T. [Queen Mary Univ. of London (United Kingdom); Noulai, M. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Mandalia, S. [Queen Mary Univ. of London (United Kingdom); Sandstrom, P. [Univ. of Wisconsin, Madison, WI (United States); Kryemadhi, A. [Messiah College, Mechanicsburg, PA (United States); Barner, L. [Messiah College, Mechanicsburg, PA (United States); Grove, A. [Messiah College, Mechanicsburg, PA (United States); Mohler, J. [Messiah College, Mechanicsburg, PA (United States); Roth, A. [Messiah College, Mechanicsburg, PA (United States); Beuzekom, M. van [Nikhef National Inst. for Subatomic Physics, Amsterdam (Netherlands); Dall' Occo, E. [Nikhef National Inst. for Subatomic Physics, Amsterdam (Netherlands); Schindler, H. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Paley, J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Badgett, W. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Denisov, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Lukic, S. [Vinca Inst. of Nuclear Sciences, Belgrade (Serbia); Ujic, P. [Vinca Inst. of Nuclear Sciences, Belgrade (Serbia); Lebrun, P. L.G. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Fields, L. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Christian, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Zaki, R. [Radboud Univ., Nijmegen (Netherlands)

    2018-01-23

    This Technical Memorandum (TM) summarizes the Fermilab Test Beam operations for FY2017. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the individual experiments that ran at FTBF and are listed in Table 1. Each experiment section was prepared by the relevant authors, and was edited for inclusion in this summary.

  4. Trigger and DAQ in the Combined Test Beam

    CERN Multimedia

    Dobson, M; Padilla, C

    2004-01-01

    Introduction During the Combined Test Beam the latest prototype of the ATLAS Trigger and DAQ system is being used to support the data taking of all the detectors. Further development of the TDAQ subsystems benefits from the direct experience given by the integration in the beam test. Support of detectors for the Combined Test Beam All ATLAS detectors need their own detector-specific DAQ development. The readout electronics is controlled by a Readout Driver (ROD), custom-built for each detector. The ROD receives data for events that are accepted by the first level trigger. The detector-specific part of the DAQ system needs to control the ROD and to respond to commands of the central DAQ (e.g. to "Start" a run). The ROD module then sends event data to a Readout System (ROS), a PC with special receiver modules/buffers. At this point the data enters the realm of the ATLAS DAQ and High Level Trigger system, constructed from Linux PCs connected with gigabit Ethernet networks. Most ATLAS detectors, representing s...

  5. Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility

    Directory of Open Access Journals (Sweden)

    T. Schietinger

    2016-10-01

    Full Text Available The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and test bed for the development and realization of SwissFEL, the x-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultralow-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.

  6. Tests of Local Hadron Calibration Approaches in ATLAS Combined Beam Tests

    CERN Document Server

    Grahn, KJ; The ATLAS collaboration; Pospelov, G

    2010-01-01

    Three ATLAS calorimeters in the region of the forward crack at $|eta| = 3.2$ in the nominal ATLAS setup and a typical section of the two barrel calorimeters at $|eta| = 0.45$ of ATLAS have been exposed to combined beam tests with single electrons and pions. Detailed shower shape studies of electrons and pions with comparisons to various Geant4 based simulations utilizing different physics lists are presented for the endcap testbeam. The local hadronic calibration approach as used in the full Atlas setup has been applied to the endcap testbeam data. An extension of it using layer correlations has been tested with the barrel test beam data. Both methods utilize modular correction steps based on shower shape variables to correct for invisible energy inside the reconstructed clusters in the calorimeters (compensation) and for lost energy deposits outside of the reconstructed clusters (dead material and out-of-cluster deposits). Results for both methods and comparisons to Monte-Carlo simulations are presented.

  7. Automated touch sensing in the mouse tapered beam test using Raspberry Pi.

    Science.gov (United States)

    Ardesch, Dirk Jan; Balbi, Matilde; Murphy, Timothy H

    2017-11-01

    Rodent models of neurological disease such as stroke are often characterized by motor deficits. One of the tests that are used to assess these motor deficits is the tapered beam test, which provides a sensitive measure of bilateral motor function based on foot faults (slips) made by a rodent traversing a gradually narrowing beam. However, manual frame-by-frame scoring of video recordings is necessary to obtain test results, which is time-consuming and prone to human rater bias. We present a cost-effective method for automated touch sensing in the tapered beam test. Capacitive touch sensors detect foot faults onto the beam through a layer of conductive paint, and results are processed and stored on a Raspberry Pi computer. Automated touch sensing using this method achieved high sensitivity (96.2%) as compared to 'gold standard' manual video scoring. Furthermore, it provided a reliable measure of lateralized motor deficits in mice with unilateral photothrombotic stroke: results indicated an increased number of contralesional foot faults for up to 6days after ischemia. The automated adaptation of the tapered beam test produces results immediately after each trial, without the need for labor-intensive post-hoc video scoring. It also increases objectivity of the data as it requires less experimenter involvement during analysis. Automated touch sensing may provide a useful adaptation to the existing tapered beam test in mice, while the simplicity of the hardware lends itself to potential further adaptations to related behavioral tests. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Performance of the ATLAS liquid argon forward calorimeter in beam tests

    CERN Document Server

    Archambault, J P; Cadabeschi, M; Epshteyn, V; Galt, C; Gillberg, D; Gorbounov, P; Heelan, L; Khakzad, M; Khovanskiy, V; Krieger, P; Loch, P; McCarthy, T G; Oakham, F G; Orr, R S; Rutherfoord, J; Savine, A; Schram, M; Shatalov, P; Shaver, L; Shupe, M; Strickland, V; Thompson, P; Tsukerman, I

    2013-01-01

    One of two ATLAS Forward Calorimeters, consisting of threemodules, one behind the other, was exposed to particle beams ofknown energies in order to study the detector performance with andwithout the presence of upstream material in the beam, and at theinner edge of the acceptance where shower energy containment isincomplete. Data were taken in the H6 beamline at CERN usingelectron and hadron beams with energies from 10 to 200 GeV.Results related to the intrinsic detector calibration, based on datataken with a minimal amount of material in front of the detector,have been previously published, but are updated here. This paperfocuses on studies of data taken with additional upstream materialin place. The effects of this additional material on the linearityand resolution of the response are presented. The response at theinner edge of the acceptance is also investigated. For all analyses,results based on a GEANT4 simulation of the beam-test setup anddetector response are also presented.

  9. TileCal Beam Test Simulation Application in the FADS/Goofy Framework (GEANT4)

    CERN Document Server

    Solodkov, A A

    2003-01-01

    A new application for the Tile Calorimeter (TileCal) beam test simulation has been developed in GEANT4 within the FADS/Goofy framework. The geometry and readout systems for all the different TileCal modules have been implemented in a quite detailed way. This application allows to simulate all the TileCal beam test setup configurations existing so far. Details of the development as well as instructions to install and run the program are presented. The first tests have been performed for a beam test setup consisting of five prototype modules using negative pions with different energies and results of comparison to the experimental data from TileCal TDR are presented as well.

  10. Beam Test of the ATLAS Level-1 Calorimeter Trigger System

    CERN Document Server

    Garvey, J; Mahout, G; Moye, T H; Staley, R J; Thomas, J P; Typaldos, D; Watkins, P M; Watson, A; Achenbach, R; Föhlisch, F; Geweniger, C; Hanke, P; Kluge, E E; Mahboubi, K; Meier, K; Meshkov, P; Rühr, F; Schmitt, K; Schultz-Coulon, H C; Ay, C; Bauss, B; Belkin, A; Rieke, S; Schäfer, U; Tapprogge, T; Trefzger, T; Weber, GA; Eisenhandler, E F; Landon, M; Apostologlou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J; Gee, C N P; Gillman, A R; Mirea, A; Perera, V J O; Qian, W; Sankey, D P C; Bohm, C; Hellman, S; Hidvegi, A; Silverstein, S

    2005-01-01

    The Level-1 Calorimter Trigger consists of a Preprocessor (PP), a Cluster Processor (CP), and a Jet/Energy-sum Processor (JEP). The CP and JEP receive digitised trigger-tower data from the Preprocessor and produce Region-of-Interest (RoIs) and trigger multiplicities. The latter are sent in real time to the Central Trigger Processor (CTP) where the Level-1 decision is made. On receipt of a Level-1 Accept, Readout Driver Modules (RODs), provide intermediate results to the data acquisition (DAQ) system for monitoring and diagnostic purpose. RoI information is sent to the RoI builder (RoIB) to help reduce the amount of data required for the Level-2 Trigger The Level-1 Calorimeter Trigger System at the test beam consisted of 1 Preprocessor module, 1 Cluster Processor Module, 1 Jet/Energy Module and 2 Common Merger Modules. Calorimeter energies were sucessfully handled thourghout the chain and trigger object sent to the CTP. Level-1 Accepts were sucessfully produced and used to drive the readout path. Online diagno...

  11. Beam Tests of a New Digital Beam Control System for the CERN LEIR Accelerator

    CERN Document Server

    Angoletta, Maria Elena; Blas, Alfred; De Long, Joseph; Findlay, Alan; Matuszkiewicz, Pawel; Pedersen, Flemming; Salom-Sarasqueta, Angela

    2005-01-01

    The Low Energy Ion Ring (LEIR) is a major component in the Large Hadron Collider ion injector chain. We have been developing an all-digital beam control and cavity servo system for the RF acceleration in LEIR. The system is housed by VME motherboards that may hold various daughter boards. Fast tasks are executed in Field Programmable Gate Arrays (FPGAs), slower tasks and communication with the software layer above are achieved in Digital Signal Processors (DSPs). We describe a simplified system prototype, which we tested with low intensity beams on the CERN PS Booster (PSB). The aim was to verify the combined DSP+FPGA architecture and the feedback loop dynamics. An additional goal was to deploy and validate novel software concepts, such as reference-functions and timings generation, and user-selectable digital data acquisition.

  12. Damage localization and quantification in simply supported beams using static test data

    Science.gov (United States)

    Ma, Q.; Solís, M.

    2017-05-01

    A novel simple method using static test data for damage detection, localization, and quantification in beams is presented in this paper. The method is based on the change of the deflections of the beam between a reference and a damaged state. For simply supported beams with a single damage, the maximum value of the change of deflections indicates the location of damage. Once the damage is located, one could estimate the rotational stiffness at the damaged cross section by applying a superposition scheme to isolate the effect of damage and by using basic structural analysis equilibrium equations. Afterwards, damage extent is evaluated through an existing relation between rotational stiffness and damage severity. Several static tests of a simply supported steel beam with a point load at different locations were conducted to exam the performance of the strategy. The damage is artificially introduced as an opened crack located at the bottom of the beam. The deflections of the beam were measured by using a Digital Image Correlation system. The results show that the method can accurately detect and quantify the damage. The method is non-model based and can be easily conducted. No specific loading positions are required and damage identification objective can be achieved from just one single static test.

  13. Planck 2013 results. VII. HFI time response and beams

    CERN Document Server

    Ade, P A R; Armitage-Caplan, C; Arnaud, M; Ashdown, M; Atrio-Barandela, F; Aumont, J; Baccigalupi, C; Banday, A J; Barreiro, R B; Battaner, E; Benabed, K; Benoît, A; Benoit-Lévy, A; Bernard, J -P; Bersanelli, M; Bielewicz, P; Bobin, J; Bock, J J; Bond, J R; Borrill, J; Bouchet, F R; Bowyer, J W; Bridges, M; Bucher, M; Burigana, C; Cardoso, J -F; Catalano, A; Challinor, A; Chamballu, A; Chary, R -R; Chiang, L -Y; Chiang, H C; Christensen, P R; Church, S; Clements, D L; Colombi, S; Colombo, L P L; Couchot, F; Coulais, A; Crill, B P; Curto, A; Cuttaia, F; Danese, L; Davies, R D; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Delouis, J -M; Désert, F -X; Diego, J M; Dole, H; Donzelli, S; Doré, O; Douspis, M; Dunkley, J; Dupac, X; Efstathiou, G; Enßlin, T A; Eriksen, H K; Finelli, F; Forni, O; Frailis, M; Fraisse, A A; Franceschi, E; Galeotta, S; Ganga, K; Giard, M; Giraud-Héraud, Y; González-Nuevo, J; Górski, K M; Gratton, S; Gregorio, A; Gruppuso, A; Gudmundsson, J E; Haissinski, J; Hansen, F K; Hanson, D; Harrison, D; Henrot-Versillé, S; Hernández-Monteagudo, C; Herranz, D; Hildebrandt, S R; Hivon, E; Hobson, M; Holmes, W A; Hornstrup, A; Hou, Z; Hovest, W; Huffenberger, K M; Jaffe, T R; Jaffe, A H; Jones, W C; Juvela, M; Keihänen, E; Keskitalo, R; Kisner, T S; Kneissl, R; Knoche, J; Knox, L; Kunz, M; Kurki-Suonio, H; Lagache, G; Lamarre, J -M; Lasenby, A; Laureijs, R J; Lawrence, C R; Leonardi, R; Leroy, C; Lesgourgues, J; Liguori, M; Lilje, P B; Linden-Vørnle, M; López-Caniego, M; Lubin, P M; Macías-Pérez, J F; MacTavish, C J; Maffei, B; Mandolesi, N; Maris, M; Marshall, D J; Martin, P G; Martínez-González, E; Masi, S; Matarrese, S; Matsumura, T; Matthai, F; Mazzotta, P; McGehee, P; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Miville-Deschênes, M -A; Moneti, A; Montier, L; Morgante, G; Mortlock, D; Munshi, D; Murphy, J A; Naselsky, P; Nati, F; Natoli, P; Netterfield, C B; Nørgaard-Nielsen, H U; Noviello, F; Novikov, D; Novikov, I; Osborne, S; Oxborrow, C A; Paci, F; Pagano, L; Pajot, F; Paoletti, D; Pasian, F; Patanchon, G; Perdereau, O; Perotto, L; Perrotta, F; Piacentini, F; Piat, M; Pierpaoli, E; Pietrobon, D; Plaszczynski, S; Pointecouteau, E; Polegre, A M; Polenta, G; Ponthieu, N; Popa, L; Poutanen, T; Pratt, G W; Prézeau, G; Prunet, S; Puget, J -L; Rachen, J P; Reinecke, M; Remazeilles, M; Renault, C; Ricciardi, S; Riller, T; Ristorcelli, I; Rocha, G; Rosset, C; Roudier, G; Rowan-Robinson, M; Rusholme, B; Sandri, M; Santos, D; Sauvé, A; Savini, G; Shellard, E P S; Spencer, L D; Starck, J -L; Stolyarov, V; Stompor, R; Sudiwala, R; Sureau, F; Sutton, D; Suur-Uski, A -S; Sygnet, J -F; Tauber, J A; Tavagnacco, D; Terenzi, L; Tomasi, M; Tristram, M; Tucci, M; Umana, G; Valenziano, L; Valiviita, J; Van Tent, B; Vielva, P; Villa, F; Vittorio, N; Wade, L A; Wandelt, B D; Yvon, D; Zacchei, A; Zonca, A

    2014-01-01

    This paper characterizes the effective beams,the effective beam window functions and the associated errors for the Planck HFI detectors. The effective beam is the angular response including the effect of the optics,detectors,data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of the CMB angular power spectrum. The HFI is a scanning instrument and its effective beams are the convolution of: (a) the optical response of the telescope and feeds;(b)the processing of the time-ordered data and deconvolution of the bolometric and electronic time response; and (c) the merging of several surveys to produce maps. The time response functions are measured using observations of Jupiter and Saturn and by minimizing survey difference residuals. The scanning beam is the post-deconvolution angular response of the instrument, and is characterized with observations of Mars. The main beam solid angles are determin...

  14. Beam tests of the 12 MHz RFQ RIB injector for ATLAS.

    Energy Technology Data Exchange (ETDEWEB)

    Clifft, B. E.; Kaye, R. A.; Kedzie, M.; Shepard, K. W.

    1999-05-06

    Beam tests of the ANL 12 MHz Radio-Frequency Quadruple (RFQ), designed for use as the initial element of an injector system for radioactive beams into the existing ATLAS accelerators, are in progress. Recent high-voltage tests of the RFQ without beam achieved the design intervane voltage of 100 kV CW, enabling beam tests with A/q as large as 132 using beams from the ANL Physics Division 4 MV Dynamitron accelerator facility. Although the RFQ was designed for bunched beams, initial tests have been performed with unbunched beams. Experiments with stable, unbunched beams of singly-charged {sup 132}Xe and {sup 84}Kr measured the output beam energy distribution as a function of the RFQ operating voltage. The observed energies are in excellent agreement with numerical beam simulations.

  15. Examination of the properties of IMRT and VMAT beams and evaluation against pre-treatment quality assurance results.

    Science.gov (United States)

    Crowe, S B; Kairn, T; Middlebrook, N; Sutherland, B; Hill, B; Kenny, J; Langton, C M; Trapp, J V

    2015-03-21

    This study aimed to provide a detailed evaluation and comparison of a range of modulated beam evaluation metrics, in terms of their correlation with QA testing results and their variation between treatment sites, for a large number of treatments. Ten metrics including the modulation index (MI), fluence map complexity, modulation complexity score (MCS), mean aperture displacement (MAD) and small aperture score (SAS) were evaluated for 546 beams from 122 intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans targeting the anus, rectum, endometrium, brain, head and neck and prostate. The calculated sets of metrics were evaluated in terms of their relationships to each other and their correlation with the results of electronic portal imaging based quality assurance (QA) evaluations of the treatment beams. Evaluation of the MI, MAD and SAS suggested that beams used in treatments of the anus, rectum, head and neck were more complex than the prostate and brain treatment beams. Seven of the ten beam complexity metrics were found to be strongly correlated with the results from QA testing of the IMRT beams (p beams with 100% specificity. However, few of the metrics are correlated with the results from QA testing of the VMAT beams, whether they were evaluated as whole 360° arcs or as 60° sub-arcs. Select evaluation of beam complexity metrics (at least MI, MCS and SAS) is therefore recommended, as an intermediate step in the IMRT QA chain. Such evaluation may also be useful as a means of periodically reviewing VMAT planning or optimiser performance.

  16. Beam tests of ATLAS SCT silicon strip detector modules

    CERN Document Server

    Campabadal, F; Key, M; Lozano, M; Martínez, C; Pellegrini, G; Rafí, J M; Ullán, M; Johansen, L; Pommeresche, B; Stugu, B; Ciocio, A; Fadeev, V; Gilchriese, M G D; Haber, C; Siegrist, J; Spieler, H; Vu, C; Bell, P J; Charlton, D G; Dowell, John D; Gallop, B J; Homer, R J; Jovanovic, P; Mahout, G; McMahon, T J; Wilson, J A; Barr, A J; Carter, J R; Fromant, B P; Goodrick, M J; Hill, J C; Lester, C G; Palmer, M J; Parker, M A; Robinson, D; Sabetfakhri, A; Shaw, R J; Anghinolfi, F; Chesi, Enrico Guido; Chouridou, S; Fortin, R; Grosse-Knetter, J; Gruwé, M; Ferrari, P; Jarron, P; Kaplon, J; MacPherson, A; Niinikoski, T O; Pernegger, H; Roe, S; Rudge, A; Ruggiero, G; Wallny, R; Weilhammer, P; Bialas, W; Dabrowski, W; Grybos, P; Koperny, S; Blocki, J; Brückman, P; Gadomski, S; Godlewski, J; Górnicki, E; Malecki, P; Moszczynski, A; Stanecka, E; Stodulski, M; Szczygiel, R; Turala, M; Wolter, M; Ahmad, A; Benes, J; Carpentieri, C; Feld, L; Ketterer, C; Ludwig, J; Meinhardt, J; Runge, K; Mikulec, B; Mangin-Brinet, M; D'Onofrio, M; Donega, M; Moêd, S; Sfyrla, A; Ferrère, D; Clark, A G; Perrin, E; Weber, M; Bates, R L; Cheplakov, A P; Saxon, D H; O'Shea, V; Smith, K M; Iwata, Y; Ohsugi, T; Kohriki, T; Kondo, T; Terada, S; Ujiie, N; Ikegami, Y; Unno, Y; Takashima, R; Brodbeck, T; Chilingarov, A G; Hughes, G; Ratoff, P; Sloan, T; Allport, P P; Casse, G L; Greenall, A; Jackson, J N; Jones, T J; King, B T; Maxfield, S J; Smith, N A; Sutcliffe, P; Vossebeld, Joost Herman; Beck, G A; Carter, A A; Lloyd, S L; Martin, A J; Morris, J; Morin, J; Nagai, K; Pritchard, T W; Anderson, B E; Butterworth, J M; Fraser, T J; Jones, T W; Lane, J B; Postranecky, M; Warren, M R M; Cindro, V; Kramberger, G; Mandic, I; Mikuz, M; Duerdoth, I P; Freestone, J; Foster, J M; Ibbotson, M; Loebinger, F K; Pater, J; Snow, S W; Thompson, R J; Atkinson, T M; Bright, G; Kazi, S; Lindsay, S; Moorhead, G F; Taylor, G N; Bachindgagyan, G; Baranova, N; Karmanov, D; Merkine, M; Andricek, L; Bethke, Siegfried; Kudlaty, J; Lutz, Gerhard; Moser, H G; Nisius, R; Richter, R; Schieck, J; Cornelissen, T; Gorfine, G W; Hartjes, F G; Hessey, N P; de Jong, P; Muijs, A J M; Peeters, S J M; Tomeda, Y; Tanaka, R; Nakano, I; Dorholt, O; Danielsen, K M; Huse, T; Sandaker, H; Stapnes, S; Bargassa, Pedrame; Reichold, A; Huffman, T; Nickerson, R B; Weidberg, A; Doucas, G; Hawes, B; Lau, W; Howell, D; Kundu, N; Wastie, R; Böhm, J; Mikestikova, M; Stastny, J; Broklová, Z; Broz, J; Dolezal, Z; Kodys, P; Kubík, P; Reznicek, P; Vorobel, V; Wilhelm, I; Chren, D; Horazdovsky, T; Linhart, V; Pospísil, S; Sinor, M; Solar, M; Sopko, B; Stekl, I; Ardashev, E N; Golovnya, S N; Gorokhov, S A; Kholodenko, A G; Rudenko, R E; Ryadovikov, V N; Vorobev, A P; Adkin, P J; Apsimon, R J; Batchelor, L E; Bizzell, J P; Booker, P; Davis, V R; Easton, J M; Fowler, C; Gibson, M D; Haywood, S J; MacWaters, C; Matheson, J P; Matson, R M; McMahon, S J; Morris, F S; Morrissey, M; Murray, W J; Phillips, P W; Tyndel, M; Villani, E G; Dorfan, D E; Grillo, A A; Rosenbaum, F; Sadrozinski, H F W; Seiden, A; Spencer, E; Wilder, M; Booth, P; Buttar, C M; Dawson, I; Dervan, P; Grigson, C; Harper, R; Moraes, A; Peak, L S; Varvell, K E; Chu Ming Lee; Hou Li Shing; Lee Shih Chang; Teng Ping Kun; Wan Chang Chun; Hara, K; Kato, Y; Kuwano, T; Minagawa, M; Sengoku, H; Bingefors, N; Brenner, R; Ekelöf, T J C; Eklund, L; Bernabeu, J; Civera, J V; Costa, M J; Fuster, J; García, C; García, J E; González-Sevilla, S; Lacasta, C; Llosa, G; Martí i García, S; Modesto, P; Sánchez, J; Sospedra, L; Vos, M; Fasching, D; González, S; Jared, R C; Charles, E

    2005-01-01

    The design and technology of the silicon strip detector modules for the Semiconductor Tracker (SCT) of the ATLAS experiment have been finalised in the last several years. Integral to this process has been the measurement and verification of the tracking performance of the different module types in test beams at the CERN SPS and the KEK PS. Tests have been performed to explore the module performance under various operating conditions including detector bias voltage, magnetic field, incidence angle, and state of irradiation up to 3 multiplied by 1014 protons per square centimetre. A particular emphasis has been the understanding of the operational consequences of the binary readout scheme.

  17. Production Facility Prototype Blower 1000 Hour Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-18

    The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was needed for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is now installed at the LANL facility for target and component flow testing. Two extended tests of >1000 hr operation have been completed. Those results and discussion thereof are reported herein. Also included in Appendix A is the detailed description of the blower and its installation, while Appendix B documents the pressure vessel design analysis. The blower has been operated for 1000 hours as a preliminary investigation of long-term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced. Test results and conclusions are in Appendix B.

  18. Expanded studies of linear collider final focus systems at the Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Tenenbaum, Peter Gregory [Stanford Univ., CA (United States)

    1995-12-01

    In order to meet their luminosity goals, linear colliders operating in the center-of-mass energy range from 3,50 to 1,500 GeV will need to deliver beams which are as small as a few Manometers tall, with x:y aspect ratios as large as 100. The Final Focus Test Beam (FFTB) is a prototype for the final focus demanded by these colliders: its purpose is to provide demagnification equivalent to those in the future linear collider, which corresponds to a focused spot size in the FFTB of 1.7 microns (horizontal) by 60 manometers (vertical). In order to achieve the desired spot sizes, the FFTB beam optics must be tuned to eliminate aberrations and other errors, and to ensure that the optics conform to the desired final conditions and the measured initial conditions of the beam. Using a combination of incoming-beam diagnostics. beam-based local diagnostics, and global tuning algorithms, the FFTB beam size has been reduced to a stable final size of 1.7 microns by 70 manometers. In addition, the chromatic properties of the FFTB have been studied using two techniques and found to be acceptable. Descriptions of the hardware and techniques used in these studies are presented, along with results and suggestions for future research.

  19. Irradiation and beam tests qualification for ATLAS IBL Pixel Modules

    CERN Document Server

    Rubinskiy, Igor

    2013-01-01

    The upgrade for the ATLAS detector will have different steps towards HL-LHC. The first upgrade for the Pixel Detector will consist in the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine (foreseen for 2013-14). The new detector, called Insertable B-Layer (IBL), will be inserted between the existing pixel detector and a new (smaller radius) beam-pipe at a radius of 33 mm. The IBL will require the development of several new technologies to cope with the increase of the radiation damage and the pixel occupancy and also to improve the physics performance, which will be achieved by reduction of the pixel size and of the material budget. Two different promising silicon sensor technologies (Planar n-in-n and 3D) are currently under investigation for the pixel detector. An overview of the sensor technologies’ qualification with particular emphasis on irradiation and beam tests are presented.

  20. Irradiation and beam tests qualification for ATLAS IBL Pixel Modules

    CERN Document Server

    Rubinskiy, I

    2013-01-01

    The upgrade for the ATLAS detector will have different steps towards HL-LHC. The first upgrade for the Pixel Detector will consist in the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine (foreseen for 2013–2014). The new detector, called Insertable B-Layer (IBL), will be inserted between the existing Pixel Detector and a new (smaller radius) beam-pipe at a radius of 33 mm. The IBL will require the development of several new technologies to cope with the increase in the radiation damage and the pixel occupancy and also to improve the physics performance, which will be achieved by reduction of the pixel size and of the material budget. Two different promising silicon sensor technologies (Planar n-in-n and 3D) are currently under investigation for the Pixel Detector. An overview of the sensor technologies' qualification with particular emphasis on irradiation and beam tests is presented.

  1. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS.

    Science.gov (United States)

    Thomae, R; Conradie, J; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V

    2016-02-01

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  2. HIE-ISOLDE Faraday cups tested with ion beams at TRIUMF

    CERN Document Server

    Cantero, E D

    2014-01-01

    The future HIE-ISOLDE Faraday cups for both the intercryomodule regions and the HEBTs have been tested using 34S+7, 4He+, 23Na+6 and 20Ne+5 beams from the ISAC-II accelerator at TRIUMF. Their performance has been characterized together with the Faraday cups from REX-ISOLDE and those from ISAC-II. The measurements were done at E/A = 1.5, 2.85 and 5.5 MeV/u, with beam intensities in the range of 100 pA to 4 nA. The performance of these Faraday cups has been compared under the same beam conditions for different bias voltages up to -350 V. Within the experimental uncertainties, most of them coming from fluctuations in beam intensity, all devices showed similar results. Biasing the Faraday cup repeller ring to voltages of at least -60 V, the escape of secondary electrons was suppressed.

  3. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    Energy Technology Data Exchange (ETDEWEB)

    Thomae, R., E-mail: rthomae@tlabs.ac.za; Conradie, J.; Fourie, D.; Mira, J.; Nemulodi, F. [iThemba LABS, P.O. Box 722, Somerset West 7130 (South Africa); Kuechler, D.; Toivanen, V. [CERN, BE/ABP/HSL, 1211 Geneva 23 (Switzerland)

    2016-02-15

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  4. The NOE scintillating fiber calorimeter prototype test results

    CERN Document Server

    Alexandrov, K V; Bernardini, P; Brigida, M; Campana, D; Candela, A M; Caruso, R; Cassese, F; Ceres, A; D'Aquino, B; De Cataldo, G; De Mitri, I; Di Credico, A; Favuzzi, C; Fusco, P; Gargano, F; Giglietto, N; Giordano, F; Grillo, A; Guarino, F; Gustavino, C; Lamanna, E; Lauro, A; Leone, A; Loparco, F; Mancarella, G; Martello, D; Mazziotta, M N; Mikheyev, S P; Mongelli, M; Osteria, G; Palladino, Vittorio; Passeggio, G; Perchiazzi, M; Pontoniere, G; Rainó, A; Rocco, R; Romanucci, E; Rubizzo, U; Sacchetti, A; Scapparone, E; Spinelli, P; Tikhomirov, V; Vaccina, A; Vanzanella, E; Weber, M

    2001-01-01

    An intense R&D program has been carried out by the NOE collaboration during the last years, to develop a massive fine grain scintillating fiber calorimeter, to be used, in combination with an appropriate target, in a long base line experiment at the CERN to Gran Sasso (CNGS) neutrino beam. The performance of a 4 ton NOE calorimeter prototype exposed to a test beam at CERN PS is shown. Results on the linearity, electromagnetic and hadronic energy resolution are reported and compared with the Monte Carlo predictions. (13 refs).

  5. Design of cryosorption pumps for TEST BEDS of ITER relevant Neutral Beam Injectors

    Energy Technology Data Exchange (ETDEWEB)

    Dremel, M. [Forschungszentrum Karlsruhe, Institut fuer Technische Physik, P.O. Box 3640, D-76021 Karlsruhe (Germany)]. E-mail: matthias.dremel@itp.fzk.de; Day, C. [Forschungszentrum Karlsruhe, Institut fuer Technische Physik, P.O. Box 3640, D-76021 Karlsruhe (Germany); Mack, A. [Forschungszentrum Karlsruhe, Institut fuer Technische Physik, P.O. Box 3640, D-76021 Karlsruhe (Germany); Jensen, H. [Forschungszentrum Karlsruhe, Institut fuer Technische Physik, P.O. Box 3640, D-76021 Karlsruhe (Germany); Speth, E. [IPP CSU-Max-Planck-Institut fuer Plasma Physik, D-85748 Garching (Germany); Falter, H.D. [IPP CSU-Max-Planck-Institut fuer Plasma Physik, D-85748 Garching (Germany); Riedl, R. [IPP CSU-Max-Planck-Institut fuer Plasma Physik, D-85748 Garching (Germany); Cordier, J.J. [Association EURATOM-CEA, DSM/Departement Recherche Fusion Controlee, CEA/Cadarache, F-13108, Saint Paul Lez Durance Cedex (France); Gravil, B. [Association EURATOM-CEA, DSM/Departement Recherche Fusion Controlee, CEA/Cadarache, F-13108, Saint Paul Lez Durance Cedex (France); Henry, D. [Association EURATOM-CEA, DSM/Departement Recherche Fusion Controlee, CEA/Cadarache, F-13108, Saint Paul Lez Durance Cedex (France); Zaccaria, P. [CONSORZIO RFX Association EURATOM-ENEA, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2005-11-15

    This paper presents the results of the design investigations and the manufacturing of cryosorption pumps for the Neutral Beam Test Facility 'MANITU' at Max Planck Institute for Plasma Physics (IPP) and the cryopump design analyses performed for the development of a test facility for the first ITER Neutral Beam Injector. The two identical cryopumps for IPP are foreseen to pump a hydrogen-throughput of 3 Pa m{sup 3}/s (H{sub 2}) with a pumping speed of 350 m{sup 3}/s per pump. The pressure conditions must be maintained over 4 h pumping without regeneration of the cryopanels. For the ITER Neutral Beam Test Facility, design calculations to assess heat loads and pumping parameters of the cryopumps will be briefly described.

  6. Modelling the double cantilever beam test with bending moments by using bilinear discontinuous cohesive laws

    DEFF Research Database (Denmark)

    Valvo, Paolo S.; Sørensen, Bent F.; Toftegaard, Helmuth Langmaack

    2015-01-01

    A theoretical model of the double cantilever beam tests with bending moments (DCB-UBM) is presented. The specimen is modelled as the assemblage of two laminated beams connected by a cohesive interface. It is assumed that the traction-separation laws – i.e. the relationships between the interfacial...... the cohesive law parameters from experiments. Experimental tests have been conducted on glass fibre reinforced specimens under pure mode I and II loading conditions. The predictions of the theoretical model turn out to be in very good agreement with the experimental results....

  7. Performance tests of a new fast digitiser for beam diagnostic applications

    CERN Document Server

    Angoletta, M E

    2002-01-01

    A new type of PCI-based fast digitisers has been deployed to implement new beam diagnostic systems and as a prototype for a new family of applications. The modules selected for the first tests and applications are the Acqiris DC265 fast digitiser boards, characterised by a high sampling speed, a large amount of memory per channel (2 MSamples per channel as the chosen option) and a PCI bus interface. This note details the tests carried out, and the results obtained, to ascertain the DC265 board and crate suitability to general beam diagnostics applications.

  8. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties.

    Science.gov (United States)

    Han, Cheol-Min; Lee, Eun-Jung; Kim, Hyoun-Ee; Koh, Young-Hag; Kim, Keung N; Ha, Yoon; Kuh, Sung-Uk

    2010-05-01

    The surface of polyetheretherketone (PEEK) was coated with a pure titanium (Ti) layer using an electron beam (e-beam) deposition method in order to enhance its biocompatibility and adhesion to bone tissue. The e-beam deposition method was a low-temperature coating process that formed a dense, uniform and well crystallized Ti layer without deteriorating the characteristics of the PEEK implant. The Ti coating layer strongly adhered to the substrate and remarkably enhanced its wettability. The Ti-coated samples were evaluated in terms of their in vitro cellular behaviors and in vivo osteointegration, and the results were compared to a pure PEEK substrate. The level of proliferation of the cells (MC3T3-E1) was measured using a methoxyphenyl tetrazolium salt (MTS) assay and more than doubled after the Ti coating. The differentiation level of cells was measured using the alkaline phosphatase (ALP) assay and also doubled. Furthermore, the in vivo animal tests showed that the Ti-coated PEEK implants had a much higher bone-in-contact (BIC) ratio than the pure PEEK implants. These in vitro and in vivo results suggested that the e-beam deposited Ti coating significantly improved the potential of PEEK for hard tissue applications. Copyright 2009 Elsevier Ltd. All rights reserved.

  9. Maintenance schemes for the ITER neutral beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    Zaccaria, P. [Consorzio RFX, Association EURATOM-ENEA, I-35127 Padova (Italy)]. E-mail: pierluigi.zaccaria@igi.cnr.it; Dal Bello, S. [Consorzio RFX, Association EURATOM-ENEA, I-35127 Padova (Italy); Marcuzzi, D. [Consorzio RFX, Association EURATOM-ENEA, I-35127 Padova (Italy); Masiello, A. [Consorzio RFX, Association EURATOM-ENEA, I-35127 Padova (Italy); Cordier, J.J. [Association EURATOM-CEA, DSM/Departement Recherche Fusion Controlee, CEA/Cadarache, F-13108 Saint Paul Lez Durance Cedex (France); Hemsworth, R. [Association EURATOM-CEA, DSM/Departement Recherche Fusion Controlee, CEA/Cadarache, F-13108 Saint Paul Lez Durance Cedex (France); Antipenkov, A. [Forschungszentrum Karlsruhe, Institut fuer Technische Physik, 76021 Karlsruhe (Germany); Day, C. [Forschungszentrum Karlsruhe, Institut fuer Technische Physik, 76021 Karlsruhe (Germany); Dremel, M. [Forschungszentrum Karlsruhe, Institut fuer Technische Physik, 76021 Karlsruhe (Germany); Mack, A. [Forschungszentrum Karlsruhe, Institut fuer Technische Physik, 76021 Karlsruhe (Germany); Jones, T. [UKAEA Culham EURATOM/UKAEA Fusion Association Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Coniglio, A. [Consorzio RFX, Association EURATOM-ENEA, I-35127 Padova (Italy); Pillon, M. [ENEA, Centro Ricerche Frascati, I-00044 Frascati, Rome (Italy); Sandri, S. [ENEA, Centro Ricerche Frascati, I-00044 Frascati, Rome (Italy); Speth, E. [IPP CSU-Max-Planck-Institut fuer Plasma Physik, D-85748 Garching (Germany); Tanga, A. [IPP CSU-Max-Planck-Institut fuer Plasma Physik, D-85748 Garching (Germany); Antoni, V. [Consorzio RFX, Association EURATOM-ENEA, I-35127 Padova (Italy); Pietro, E. Di [EFDA CSU, D-85748 Garching (Germany); Mondino, P.L. [EFDA CSU, D-85748 Garching (Germany)

    2005-11-15

    The ITER neutral beam test facility (NBTF) is planned to be built, after the approval of the ITER construction and the choice of the ITER site, with the agreement of the ITER international team and of the JA and RF participant teams. The key purpose is to progressively increase the performance of the first ITER injector and to demonstrate its reliability at the maximum operation parameters: power delivered to the plasma 16.5 MW, beam energy 1 MeV, accelerated D{sup -} ion current 40 A, pulse length 3600 s. Several interventions for possible modifications and for maintenance are expected during the early operation of the ITER injector in order to optimise the beam generation, aiming and steering. The maintenance scheme and the related design solutions are therefore a very important aspect to be considered for the NBTF design. The paper describes consistently the many interrelated aspects of the design, such as the optimisation of the vessel and cryopump geometry, in order to get a better maintenance flexibility, an easier man access and a larger access for diagnostic and monitoring.

  10. Maintenance schemes for the ITER neutral beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    Zaccaria, P.; Dal Bello, S.; Marcuzzi, D.; Masiello, A.; Coniglio, A.; Antoni, V. [Consorzio RFX Association Euratom-ENEA, Padova (Italy); Cordier, J.J.; Hemsworth, R. [Association Euratom-CEA Cadarache (DSM/DRFC), 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Antipenkov, A.; Day, C.; Dremel, M.; Mack, A. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Technische Physik; Pillon, M.; Sandri, S. [ENEA, Frascati (Italy). Centro Ricerche Energia; Speth, E.; Tanga, A. [Max-Planck-Institut fuer Plasmaphysik, IPP CSU, Garching (Germany); Jones, T. [UKAEA Culham Euratom/Ukaea Fusion Association Culham Science Centre, Abingdom OX (United Kingdom); Di Pietro, E.; Mondino, P.L. [EFDA CSU, Garching (Germany)

    2004-07-01

    The ITER neutral beam test facility (NBTF) is planned to be built, after the approval of the ITER construction and the choice of the ITER site, with the agreement of the ITER International Team and of the JA and RF participant teams. The key purpose is to progressively increase the performance of the first ITER injector and to demonstrate its reliability at the maximum operation parameters: power delivered to the plasma 16.5 MW, beam energy 1 MeV, accelerated D{sup -} ion current 40 A, pulse length 3600 s. Several interventions for possible modifications and for maintenance are expected during the early operation of the ITER injector in order to optimize the beam generation, aiming and steering. The maintenance scheme and the related design solutions are therefore a very important aspect to be considered for the NBTF design. The paper describes consistently the many interrelated aspects of the design, such as the optimisation of the vessel and cryopump geometry, in order to get a better maintenance flexibility, an easier man access and a larger access for diagnostic and monitoring. (authors)

  11. Latest Performance Results from the FONT5 Intra-train Beam Position and Angle Feedback System at ATF2

    CERN Document Server

    Christian, G B; Bett, D R; Blaskovic Kraljevic, N; Burrows, P N; Davis, M R; Gerbershagen, A; Perry, C; Constance, B; Resta-Lopez, J

    2012-01-01

    A prototype Interaction Point beam-based feedback system for future electron-positron colliders, such as the International Linear Collider, has been designed and tested on the extraction line of the KEK Accelerator Test Facility (ATF). The FONT5 intra-train feedback system aims to stabilize the beam orbit by correcting both the position and angle jitter in the vertical plane on bunch-tobunch time scales, providing micron-level stability at the entrance to the ATF2 final-focus system. The system comprises three stripline beam position monitors (BPMs) and two stripline kickers, custom low-latency analogue front-end BPM processors, a custom FPGA-based digital processing board with fast ADCs, and custom kickerdrive amplifiers. The latest results from beam tests at ATF2 will be presented, including the system latency and correction performance.

  12. Experimental results of beryllium exposed to intense high energy proton beam pulses

    OpenAIRE

    Ammigan, K.; Hartsell, B.; Hurh, P.; Zwaska, R.; Butcher, M.; Guinchard, M; Calviani, M; Losito, R; Roberts, S; Kuksenko, V.; Atherton, A.; Caretta, O.; Davenne, T.; Densham, C.; Fitton, M

    2017-01-01

    Beryllium is extensively used in various accelerator beam lines and target facilities as a material for beam windows, and to a lesser extent, as secondary particle production targets. With increasing beam intensities of future accelerator facilities, it is critical to understand the response of beryllium under extreme conditions to reliably operate these components as well as avoid compromising particle production efficiency by limiting beam parameters. As a result, an exploratory experiment ...

  13. Beam dynamics simulations and measurements at the Project X Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gianfelice-Wendt, E.; Scarpine, V.E.; Webber, R.C.; /Fermilab

    2011-03-01

    Project X, under study at Fermilab, is a multitask high-power superconducting RF proton beam facility, aiming to provide high intensity protons for rare processes experiments and nuclear physics at low energy, and simultaneously for the production of neutrinos, as well as muon beams in the long term. A beam test facility - former known as High Intensity Neutrino Source (HINS) - is under commissioning for testing critical components of the project, e.g. dynamics and diagnostics at low beam energies, broadband beam chopping, RF power generation and distribution. In this paper we describe the layout of the test facility and present beam dynamics simulations and measurements.

  14. Production Facility Prototype Blower 1000 Hour Test Results II

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-08

    Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

  15. LArIAT: Liquid Argon TPC in a Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, Phil [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2013-02-28

    This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of the LArIAT collaboration who have committed to participate in beam tests to be carried out starting during the 2013 Fermilab Test Beam Facility program. The TSW is intended primarily for the purpose of recording expectations for budget estimates and work allocation for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to modify this TSW to reflect such required adjustments. Actual contractual obligations will be set forth in separate documents. This TSW fulfills Article 1 (facilities and scope of work) of the User Agreements signed (or still to be signed) by an authorized representative of each institution collaborating on this experiment. Precision neutrino physics has entered a new era both with pressing questions to be addressed at short and long baselines, and with increasing interest and development of Liquid Argon Time Projection Chambers (LArTPCs). These open volume liquid argon TPCs drift ionization electrons from passing charged particles to readout wire chamber planes at the edge of the detector. The Signals are then combined to form 2D and 3D pho-quality like millimeter scale images of the charged particles tracks and to provide calorimetric measurements of the deposited energy in the detector.

  16. TEST BEAM COORDINATION: The 2004 Test Beam Calorimetry set-up in H8

    CERN Multimedia

    Aleksa, M; Di Girolamo, B; Ferrari, C; Giugni, D; Santoni, C; Wingerter, I

    A new table has been designed, built and finally mounted to position the LAr cryostat in front of the Tilecal modules. The new table has been connected to the existing Tilecal table to be able to move the full set-up along eta values between 0 and 1.2. The table has been conceived by D. Giugni (INFN Milano and now CERN PH) and modeled by G. Braga (INFN Milano) in spring-summer 2003. The realization of the table has been done by an Italian firm (MatecImpianti, Fenegrò, Como) under the supervision of S. Coelli (INFN Milano) starting August 2003. Figure 1 shows the table assembled at the firm (left). Figure 1: The Tilecal-LAr table: in Fenegro (left) and at CERN (right). In November 2003 the table has been delivered to CERN and put in temporary storage to be assembled after the preparation of the Tilecal zone. In February 2004 two technicians from the firm and the team of technician coordinated by C. Ferrari (CERN AB/ATB), assembled, tested and commissioned the table under the supervision of S. Coelli...

  17. Development of laser decontamination. 4. Test of beam transmission by fibers and the most suitable condition

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, Yasutaka; Ogawa, Ryuichirou; Ishijima, Noboru; Tanimoto, Kenichi [Japan Nuclear Cycle Development Inst., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1999-07-01

    In this work, the characteristics of laser beam transmission by optical fibers and decontamination speed by the most suitable condition and improvement of the characteristics of secondary products are experimented for apply laser decontamination technique to radioactive wastes treatment and decommissioning of nuclear fuel facilities. The results are as follows. (1) Beam transmission: For Q switch pulse YAG laser, beam transmission by optical fibers were examined. Transmission energy increase in proportion to diameter of fiber. The maximum transmission energy of optical fiber was 61 mJ, which was not damaged. The transmission energy of bundle fiber was more plenty than the energy of single fibers at same numbers. It is able to apply bundle fiber to transmission system of Q switch pulse YAG laser beam. (2) Improvement of decontamination speed: Imitation contaminants were removed perfectly on the condition that, the irradiation frequency was 2 times, move speed of test piece was 3.0 mm/sec, beam diameter was 1.2 mm, repetition speed was 10 Hz. At this time, the number of beam shots were more 4 in the unit area. The case of fluence is constant, the number of beam shots were increased by spread of beam diameter in the unit area. (3) Measurement of secondary products: Particle diameters of more than 50% secondary products by Q switch pulse YAG laser were less than 0. 1 {mu}m. Particle diameters of more than 50% secondary products by normal pulse YAG laser were from 0.1 {mu}m to 1 {mu}m. (author)

  18. FERMILAB SWITCHYARD RESONANT BEAM POSITION MONITOR ELECTRONICS UPGRADE RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, T. [Fermilab; Diamond, J. [Fermilab; Liu, N. [Fermilab; Prieto, P. S. [Fermilab; Slimmer, D. [Fermilab; Watts, A. [Fermilab

    2016-10-12

    The readout electronics for the resonant beam position monitors (BPMs) in the Fermilab Switchyard (SY) have been upgraded, utilizing a low noise amplifier transition board and Fermilab designed digitizer boards. The stripline BPMs are estimated to have an average signal output of between -110 dBm and -80 dBm, with an estimated peak output of -70 dBm. The external resonant circuit is tuned to the SY machine frequency of 53.10348 MHz. Both the digitizer and transition boards have variable gain in order to accommodate the large dynamic range and irregularity of the resonant extraction spill. These BPMs will aid in auto-tuning of the SY beamline as well as enabling operators to monitor beam position through the spill.

  19. Planck 2015 results. VII. HFI TOI and beam processing

    CERN Document Server

    Adam, R.; Aghanim, N.; Arnaud, M.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartolo, N.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bertincourt, B.; Bielewicz, P.; Bock, J.J.; Bonavera, L.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Boulanger, F.; Bucher, M.; Burigana, C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chary, R.-R.; Chiang, H.C.; Christensen, P.R.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T.A.; Eriksen, H.K.; Falgarone, E.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A.A.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Ghosh, T.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.L.; Henrot-Versillé, S.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, A.H.; Jaffe, T.R.; Jones, W.C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C.R.; Le Jeune, M.; Leahy, J.P.; Lellouch, E.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; McGehee, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Moreno, R.; Morgante, G.; Mortlock, D.; Moss, A.; Mottet, S.; Munshi, D.; Murphy, J.A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; Noviello, F.; Novikov, D.; Novikov, I.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Pearson, T.J.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J.P.; Reinecke, M.; Remazeilles, M.; Renault, C.; Renzi, A.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sandri, M.; Santos, D.; Sauvé, A.; Savelainen, M.; Savini, G.; Scott, D.; Seiffert, M.D.; Shellard, E.P.S.; Spencer, L.D.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J.A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Wade, L.A.; Wandelt, B.D.; Watson, R.; Wehus, I.K.; Yvon, D.; Zacchei, A.

    2016-01-01

    The Planck High Frequency Instrument (HFI) has observed the full sky at six frequencies (100, 143, 217, 353, 545, and 857 GHz) in intensity and at four frequencies in linear polarization (100, 143, 217, and 353 GHz). In order to obtain sky maps, the time-ordered information (TOI) containing the detector and pointing samples must be processed and the angular response must be assessed. The full mission TOI is included in the Planck 2015 release. This paper describes the HFI TOI and beam processing for the 2015 release. HFI calibration and map-making are described in a companion paper. The main pipeline has been modified since the last release (2013 nominal mission in intensity only), by including a correction for the non-linearity of the warm readout and by improving the model of the bolometer time response. The beam processing is an essential tool that derives the angular response used in all the Planck science papers and we report an improvement in the effective beam window function uncertainty of more than a...

  20. Development and beam test of a continuous wave radio frequency quadrupole accelerator

    Science.gov (United States)

    Ostroumov, P. N.; Mustapha, B.; Barcikowski, A.; Dickerson, C.; Kolomiets, A. A.; Kondrashev, S. A.; Luo, Y.; Paskvan, D.; Perry, A.; Schrage, D.; Sharamentov, S. I.; Sommer, R.; Toter, W.; Zinkann, G.

    2012-11-01

    The front end of any modern ion accelerator includes a radio frequency quadrupole (RFQ). While many pulsed ion linacs successfully operate RFQs, several ion accelerators worldwide have significant difficulties operating continuous wave (CW) RFQs to design specifications. In this paper we describe the development and results of the beam commissioning of a CW RFQ designed and built for the National User Facility: Argonne Tandem Linac Accelerator System (ATLAS). Several innovative ideas were implemented in this CW RFQ. By selecting a multisegment split-coaxial structure, we reached moderate transverse dimensions for a 60.625-MHz resonator and provided a highly stabilized electromagnetic field distribution. The accelerating section of the RFQ occupies approximately 50% of the total length and is based on a trapezoidal vane tip modulation that increased the resonator shunt impedance by 60% in this section as compared to conventional sinusoidal modulation. To form an axially symmetric beam exiting the RFQ, a very short output radial matcher with a length of 0.75βλ was developed. The RFQ is designed as a 100% oxygen-free electronic (OFE) copper structure and fabricated with a two-step furnace brazing process. The radio frequency (rf) measurements show excellent rf properties for the resonator, with a measured intrinsic Q equal to 94% of the simulated value for OFE copper. An O5+ ion beam extracted from an electron cyclotron resonance ion source was used for the RFQ commissioning. In off-line beam testing, we found excellent coincidence of the measured beam parameters with the results of beam dynamics simulations performed using the beam dynamics code TRACK, which was developed at Argonne. These results demonstrate the great success of the RFQ design and fabrication technology developed here, which can be applied to future CW RFQs.

  1. Development and beam test of a continuous wave radio frequency quadrupole accelerator

    Directory of Open Access Journals (Sweden)

    P. N. Ostroumov

    2012-11-01

    Full Text Available The front end of any modern ion accelerator includes a radio frequency quadrupole (RFQ. While many pulsed ion linacs successfully operate RFQs, several ion accelerators worldwide have significant difficulties operating continuous wave (CW RFQs to design specifications. In this paper we describe the development and results of the beam commissioning of a CW RFQ designed and built for the National User Facility: Argonne Tandem Linac Accelerator System (ATLAS. Several innovative ideas were implemented in this CW RFQ. By selecting a multisegment split-coaxial structure, we reached moderate transverse dimensions for a 60.625-MHz resonator and provided a highly stabilized electromagnetic field distribution. The accelerating section of the RFQ occupies approximately 50% of the total length and is based on a trapezoidal vane tip modulation that increased the resonator shunt impedance by 60% in this section as compared to conventional sinusoidal modulation. To form an axially symmetric beam exiting the RFQ, a very short output radial matcher with a length of 0.75βλ was developed. The RFQ is designed as a 100% oxygen-free electronic (OFE copper structure and fabricated with a two-step furnace brazing process. The radio frequency (rf measurements show excellent rf properties for the resonator, with a measured intrinsic Q equal to 94% of the simulated value for OFE copper. An O^{5+} ion beam extracted from an electron cyclotron resonance ion source was used for the RFQ commissioning. In off-line beam testing, we found excellent coincidence of the measured beam parameters with the results of beam dynamics simulations performed using the beam dynamics code TRACK, which was developed at Argonne. These results demonstrate the great success of the RFQ design and fabrication technology developed here, which can be applied to future CW RFQs.

  2. PS BOOSTER BEAM TESTS OF THE NEW DIGITAL BEAM CONTROL SYSTEM FOR LEIR

    CERN Document Server

    Angoletta, Maria Elena; Bento, J; De Long, J H; Findlay, A; Matuszkiewicz, P; Pedersen, F; Salom-Sarasqueta, A; CERN. Geneva. AB Department

    2005-01-01

    We have been developing a scaled-down prototype of the new digital beam control and cavity servoing system for CERN’s Low Energy Ion Ring (LEIR) slated for commissioning in 2005. The system’s hardware and software, developed as part of a CERN-BNL collaboration, are based on new all-digital technology already deployed at BNL's AGS Booster. The system relies on VME modules, carrying Digital Signal Processors (DSPs) as well as Field Programmable Gate Arrays (FPGAs), and daughter cards. New concepts deployed include software implementation, through DSPs & FPGAs, of functions traditionally executed by analogue hardware, such as reference-functions and timings generation. Additionally, a user-selectable digital data acquisition functionality provides diagnostic and troubleshoot access points, a new feature which is very useful in a digital system. The scaled-down prototype implements frequency program, radial steering, phase and radial loops capabilities and it has been tested in CERN's PS Booster (PSB) dur...

  3. Common Diagnostic Test Results Over the Years

    Directory of Open Access Journals (Sweden)

    Aruvee Eve

    2016-12-01

    Full Text Available In this article, common test results over the years 2000 – 2016 are analysed. The test questions for new entrants were based on secondary school mathematics. The students took the test in the first lesson of the higher mathematics course. The test results were analysed by years, by tasks and by specialities, and their differences were found. The test results’ dependence on state-exams score was studied and other types of dependence were looked at.

  4. Design of a compact device to generate and test beams with orbital angular momentum in the EUV.

    Science.gov (United States)

    Pabon, D O; Ledesma, S A; Quinteiro, G F; Capeluto, M G

    2017-10-10

    We present a compact design to generate and test optical-vortex beams with possible applications in the extreme ultraviolet (EUV) region of the electromagnetic spectrum. The device consists of a diffractive mask where both the beam with orbital angular momentum and the reference wavefront to test its phase are generated. In order to show that the proposal would work in the EUV, simulations and proof-of-principle experiments were performed, using typical parameters for EUV holography scaled to visible wavelengths. As the simplest case, we consider the well-known Laguerre-Gaussian (LG)-like beams, which have a single vortex in the propagation axis. To further test the versatility of the device, we consider Mathieu beams, more complex structured beams that may contain several vortices. In the experiment, a spatial light modulator was used to display the mask. As examples, we show the results for a LG-like beam with topological charge ℓ=1 and Mathieu beams with topological charge ℓ=2 and ellipticity q=2. These results show the potential of the device to generate a variety of beam shapes at EUV wavelengths.

  5. Alignment of the Pixel and SCT Modules for the 2004 ATLAS Combined Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    ATLAS Collaboration; Ahmad, A.; Andreazza, A.; Atkinson, T.; Baines, J.; Barr, A.J.; Beccherle, R.; Bell, P.J.; Bernabeu, J.; Broklova, Z.; Bruckman de Renstrom, P.A.; Cauz, D.; Chevalier, L.; Chouridou, S.; Citterio, M.; Clark, A.; Cobal, M.; Cornelissen, T.; Correard, S.; Costa, M.J.; Costanzo, D.; Cuneo, S.; Dameri, M.; Darbo, G.; de Vivie, J.B.; Di Girolamo, B.; Dobos, D.; Drasal, Z.; Drohan, J.; Einsweiler, K.; Elsing, M.; Emelyanov, D.; Escobar, C.; Facius, K.; Ferrari, P.; Fergusson, D.; Ferrere, D.; Flick,, T.; Froidevaux, D.; Gagliardi, G.; Gallas, M.; Gallop, B.J.; Gan, K.K.; Garcia, C.; Gavrilenko, I.L.; Gemme, C.; Gerlach, P.; Golling, T.; Gonzalez-Sevilla, S.; Goodrick, M.J.; Gorfine, G.; Gottfert, T.; Grosse-Knetter, J.; Hansen, P.H.; Hara, K.; Hartel, R.; Harvey, A.; Hawkings, R.J.; Heinemann, F.E.W.; Henss, T.; Hill, J.C.; Huegging, F.; Jansen, E.; Joseph, J.; Unel, M. Karagoz; Kataoka, M.; Kersten, S.; Khomich, A.; Klingenberg, R.; Kodys, P.; Koffas, T.; Konstantinidis, N.; Kostyukhin, V.; Lacasta, C.; Lari, T.; Latorre, S.; Lester, C.G.; Liebig, W.; Lipniacka, A.; Lourerio, K.F.; Mangin-Brinet, M.; Marti i Garcia, S.; Mathes, M.; Meroni, C.; Mikulec, B.; Mindur, B.; Moed, S.; Moorhead, G.; Morettini, P.; Moyse, E.W.J.; Nakamura, K.; Nechaeva, P.; Nikolaev, K.; Parodi, F.; Parzhitskiy, S.; Pater, J.; Petti, R.; Phillips, P.W.; Pinto, B.; Poppleton, A.; Reeves, K.; Reisinger, I.; Reznicek, P.; Risso, P.; Robinson, D.; Roe, S.; Rozanov, A.; Salzburger, A.; Sandaker, H.; Santi, L.; Schiavi, C.; Schieck, J.; Schultes, J.; Sfyrla, A.; Shaw, C.; Tegenfeldt, F.; Timmermans, C.J.W.P.; Toczek, B.; Troncon, C.; Tyndel, M.; Vernocchi, F.; Virzi, J.; Anh, T. Vu; Warren, M.; Weber, J.; Weber, M.; Weidberg, A.R.; Weingarten, J.; Wellsf, P.S.; Zhelezkow, A.

    2008-06-02

    A small set of final prototypes of the ATLAS Inner Detector silicon tracking system(Pixel Detector and SemiConductor Tracker), were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated using the known momenta of the beam particles and were shown to yield consistent results among the different alignment approaches. From the residual distributions, it is concluded that the precision attained in the alignmentof the silicon modules is of the order of 5 mm in their most precise coordinate.

  6. Alignment of the Pixel and SCT Modules for the 2004 ATLAS Combined Test Beam

    Science.gov (United States)

    Ahmad, A.; Andreazza, A.; Atkinson, T.; Baines, J.; Barr, A. J.; Beccherle, R.; Bell, P. J.; Bernabeu, J.; Broklova, Z.; Bruckman de Renstrom, P. A.; Cauz, D.; Chevalier, L.; Chouridou, S.; Citterio, M.; Clark, A.; Cobal, M.; Cornelissen, T.; Correard, S.; Costa, M. J.; Costanzo, D.; Cuneo, S.; Dameri, M.; Darbo, G.; de Vivie, J. B.; Di Girolamo, B.; Dobos, D.; Drasal, Z.; Drohan, J.; Einsweiler, K.; Elsing, M.; Emelyanov, D.; Escobar, C.; Facius, K.; Ferrari, P.; Fergusson, D.; Ferrere, D.; Flick, T.; Froidevaux, D.; Gagliardi, G.; Gallas, M.; Gallop, B. J.; Gan, K. K.; Garcia, C.; Gavrilenko, I. L.; Gemme, C.; Gerlach, P.; Golling, T.; Gonzalez-Sevilla, S.; Goodrick, M. J.; Gorfine, G.; Göttfert, T.; Grosse-Knetter, J.; Hansen, P. H.; Hara, K.; Härtel, R.; Harvey, A.; Hawkings, R. J.; Heinemann, F. E. W.; Henss, T.; Hill, J. C.; Huegging, F.; Jansen, E.; Joseph, J.; Karagöz Ünel, M.; Kataoka, M.; Kersten, S.; Khomich, A.; Klingenberg, R.; Kodys, P.; Koffas, T.; Konstantinidis, N.; Kostyukhin, V.; Lacasta, C.; Lari, T.; Latorre, S.; Lester, C. G.; Liebig, W.; Lipniacka, A.; Lourerio, K. F.; Mangin-Brinet, M.; Garcia, S. Marti i.; Mathes, M.; Meroni, C.; Mikulec, B.; Mindur, B.; Moed, S.; Moorhead, G.; Morettini, P.; Moyse, E. W. J.; Nakamura, K.; Nechaeva, P.; Nikolaev, K.; Parodi, F.; Parzhitskiy, S.; Pater, J.; Petti, R.; Phillips, P. W.; Pinto, B.; Poppleton, A.; Reeves, K.; Reisinger, I.; Reznicek, P.; Risso, P.; Robinson, D.; Roe, S.; Rozanov, A.; Salzburger, A.; Sandaker, H.; Santi, L.; Schiavi, C.; Schieck, J.; Schultes, J.; Sfyrla, A.; Shaw, C.; Tegenfeldt, F.; Timmermans, C. J. W. P.; Toczek, B.; Troncon, C.; Tyndel, M.; Vernocchi, F.; Virzi, J.; Anh, T. Vu; Warren, M.; Weber, J.; Weber, M.; Weidberg, A. R.; Weingarten, J.; Wells, P. S.; Zhelezko, A.

    2008-09-01

    A small set of final prototypes of the ATLAS Inner Detector silicon tracking system (Pixel Detector and SemiConductor Tracker), were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated using the known momenta of the beam particles and were shown to yield consistent results among the different alignment approaches. From the residual distributions, it is concluded that the precision attained in the alignment of the silicon modules is of the order of 5 μm in their most precise coordinate.

  7. Evaluation of Asphalt Mixture Low-Temperature Performance in Bending Beam Creep Test.

    Science.gov (United States)

    Pszczola, Marek; Jaczewski, Mariusz; Rys, Dawid; Jaskula, Piotr; Szydlowski, Cezary

    2018-01-10

    Low-temperature cracking is one of the most common road pavement distress types in Poland. While bitumen performance can be evaluated in detail using bending beam rheometer (BBR) or dynamic shear rheometer (DSR) tests, none of the normalized test methods gives a comprehensive representation of low-temperature performance of the asphalt mixtures. This article presents the Bending Beam Creep test performed at temperatures from -20 °C to +10 °C in order to evaluate the low-temperature performance of asphalt mixtures. Both validation of the method and its utilization for the assessment of eight types of wearing courses commonly used in Poland were described. The performed test indicated that the source of bitumen and its production process (and not necessarily only bitumen penetration) had a significant impact on the low-temperature performance of the asphalt mixtures, comparable to the impact of binder modification (neat, polymer-modified, highly modified) and the aggregate skeleton used in the mixture (Stone Mastic Asphalt (SMA) vs. Asphalt Concrete (AC)). Obtained Bending Beam Creep test results were compared with the BBR bitumen test. Regression analysis confirmed that performing solely bitumen tests is insufficient for comprehensive low-temperature performance analysis.

  8. Longitudinal beam parameters and quality checks of the LHC beam in the SPS: further results and comparisons

    CERN Document Server

    Papotti, G; Linnecar, T; Shaposhnikova, E; Tückmantel, Joachim; CERN. Geneva. AB Department

    2008-01-01

    Controlled longitudinal emittance blow up is used, along with other measures, to stabilize the nominal LHC beam in the SPS. Two Machine Development studies (MDs) were carried out in 2007 to evaluate the effectiveness of different noise settings for the longitudinal blow up of the beam. The noise settings are affected by both the presence of the 800 MHz RF system and intensity effects which modify the synchrotron frequency distribution inside the bunch. The results for the first MD are reported in Note [1]. This Note reports on the results of the second MD, carried out on 2007-10-17, as well as the comparison between the two in order to analyse the differences between the two occasions. Figures of merit are used that allow rapid evaluation of the quality of the beam as for example stability and bunch length uniformity across batches.

  9. High Energy Tests of Advanced Materials for Beam Intercepting Devices at CERN HiRadMat Facility

    CERN Document Server

    Bertarelli, A; Berthome, E; Boccone, V; Carra, F; Cerutti, F; Dallocchio, A; Dos Santos, S; Francon, P; Gentini, L; Guinchard, M; Mariani, N; Masi, A; Moyret, P; Redaeelli, S; Peroni, L; Scapin, M

    2012-01-01

    Predicting by simulations the consequences of LHC particle beams hitting Collimators and other Beam Intercepting Devices (BID) is a fundamental issue for machine protection: this can be done by resorting to highly non-linear numerical tools (Hydrocodes). In order to produce accurate results, these codes require reliable material models that, at the extreme conditions generated by a beam impact, are either imprecise or non-existent. To validate relevant constitutive models or, when unavailable, derive new ones, a comprehensive experimental test foreseeing intense particle beam impacts on six different materials, either already used for present BID or under development for future applications, is being prepared at CERN HiRadMat facility. Tests will be run at medium and high intensity using the SPS proton beam (440 GeV). Material characterization will be carried out mostly in real time relying on embarked instrumentation (strain gauges, microphones, temperature and pressure sensors) and on remote acquisition dev...

  10. Results from the 2009 beam commissioning of the CERN multi-turn extraction

    CERN Document Server

    Benedetto, E; Bohl, T; Cettour Cave, S; Cornelis, K; Cotte, D; Damerau, H; Delrieux, M; Fleuret, J; Fowler, T; Follin, F; Franchi, A; Freyermuth, P; Genoud, H; Gilardoni, S; Giovannozzi, M; Hancock, S; Hans, O; Le Borgne, Y; Manglunki, D; Matli, E; Métral, E; Métral, G; Newman, M; Pereira, L; Peters, F; Riva, Y; Roncarolo, F; Sermeus, L; Steerenberg, R; Vandorpe, B; Wenninger, J

    2010-01-01

    Following the analysis of the results obtained during the first year of beam commissioning of the CERN multiturn extraction, a number of changes have been introduced in the beam manipulations performed in the CERN Proton Synchrotron. This includes a different control of the linear chromaticity, the setting of the nonlinear magnets used to split the beam, and the longitudinal structure in the PS. The results obtained during the 2009 run are presented and discussed in detail, including the beam performance in both the PS and the SPS.

  11. MATISSE: alignment, integration, and test phase first results

    Science.gov (United States)

    Allouche, F.; Robbe-Dubois, S.; Lagarde, S.; Cruzalèbes, P.; Antonelli, P.; Bresson, Y.; Fantei-Caujolle, Y.; Marcotto, A.; Morel, S.; Beckmann, U.; Bettonvil, F.; Berio, Ph.; Heininger, M.; Lehmitz, M.; Agocs, T.; Brast, R.; Elswijk, E.; Ives, D.; Meixner, K.; Laun, W.; Mellein, M.; Neumann, U.; Bailet, C.; Clausse, J.-M.; Matter, A.; Meilland, A.; Millour, F.; Petrov, R. G.; Accardo, M.; Bristow, P.; Frahm, R.; Glindemann, A.; Gonzáles Herrera, J.-C.; Lizon, J.-L.; Schöller, M.; Graser, U.; Jaffe, W.; Lopez, B.

    2016-08-01

    MATISSE (Multi AperTure mid-Infrared SpectroScopic Experiment) is the spectro-interferometer for the VLTI of the European Southern Observatory, operating in near and mid-infrared, and combining up to four beams from the unit or the auxiliary telescopes. MATISSE will offer new breakthroughs in the study of circumstellar environments by allowing the multispectral mapping of the material distribution, the gas and essentially the dust. The instrument consists in a warm optical system (WOP) accepting four optical beams and relaying them after a dichroic splitting (for the L and M- and N- spectral bands) to cold optical benches (COB) located in two separate cryostats. The Observatoire de la Côte d'Azur is in charge of the WOP providing the spectral band separation, optical path equalization and modulation, pupil positioning, beam anamorphosis, beam commutation, and calibration. NOVA-ASTRON is in charge of the COB providing the functions of beam selection, reduction of thermal background emission, spatial filtering, pupil transfer, photometry and interferometry splitting, additional beam anamorphosis, spectral filtering, polarization selection, image dispersion, and image combination. The Max Planck Institut für Radio Astronomie is in charge of the operation and performance validation of the two detectors, a HAWAII-2RG from Teledyne for the L- and M- bands and a Raytheon AQUARIUS for the N-band. Both detectors are provided by ESO. The Max Planck Institut für Astronomie is in charge of the electronics and the cryostats for which the requirements on space limitations and vibration stability resulted on very specific and stringent decisions on the design. The integration and test of the COB: the two cryogenic systems, including the cold benches and the detectors, have been conducted at MPIA in parallel with the integration of the WOP at OCA. At the end of 2014, the complete instrument was integrated at OCA. Following this integration, a period of interface and alignment

  12. Hadron beam test of a scintillating fibre tracker system for elastic scattering and luminosity measurement in ATLAS

    OpenAIRE

    Anghinolfi, F.; S. Ask; Barrillon, P.; Blanchot, G; Blin, S.; Braem, André; C. De La Taille; Di Girolamo, B.; I. Efthymiopoulos(CERN, Geneva, Switzerland); Faustino, J; Fournier, D.; Franz, S.; Grafström, P.; Gurriana, L.; Haguenauer, M.

    2007-01-01

    A scintillating fibre tracker is proposed to measure elastic proton scattering at very small angles in the ATLAS experiment at CERN. The tracker will be located in so-called Roman Pot units at a distance of 240 m on each side of the ATLAS interaction point. An initial validation of the design choices was achieved in a beam test at DESY in a relatively low energy electron beam and using slow off-the-shelf electronics. Here we report on the results from a second beam test experiment carried out...

  13. Hadron beam test of a scintillating fibre tracker system for elastic scattering and luminosity measurement in ATLAS

    CERN Document Server

    Anghinolfi, F; Barrillon, P; Blanchot, G; Blin, S; Braem, André; de La Taille, C; Di Girolamo, B; Efthymiopoulos, I; Faustino, J; Fournier, D; Franz, S; Grafström, P; Gurriana, L; Haguenauer, M; Hedberg, V; Heller, M; Hoffmann, S; Iwanski, W; Joram, C; Kocnár, A; Lavigne, B; Lundberg, B; Maio, A; Maneira, M J P; Mapelli, A; Marques, C; Mjörnmark, U; Conde-Muíño, P; Puzo, P; Rijssenbeek, M; Saraiva, J G; Seguin-Moreau, N; Soares, S; Stenzel, H; Thioye, M; Varouchas, D; Vorobel, V

    2007-01-01

    A scintillating fibre tracker is proposed to measure elastic proton scattering at very small angles in the ATLAS experiment at CERN. The tracker will be located in so-called Roman Pot units at a distance of 240 m on each side of the ATLAS interaction point. An initial validation of the design choices was achieved in a beam test at DESY in a relatively low energy electron beam and using slow off-the-shelf electronics. Here we report on the results from a second beam test experiment carried out at CERN, where new detector prototypes were tested in a high energy hadron beam, using the first version of the custom designed front-end electronics. The results show an adequate tracking performance under conditions which are similar to the situation at the LHC. In addition, the alignment method using so-called overlap detectors was studied and shown to have the expected precision.

  14. AMORE Mo-99 Spike Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Youker, Amanda J. [Argonne National Lab. (ANL), Argonne, IL (United States); Krebs, John F. [Argonne National Lab. (ANL), Argonne, IL (United States); Quigley, Kevin J. [Argonne National Lab. (ANL), Argonne, IL (United States); Byrnes, James P. [Argonne National Lab. (ANL), Argonne, IL (United States); Rotsch, David A [Argonne National Lab. (ANL), Argonne, IL (United States); Brossard, Thomas [Argonne National Lab. (ANL), Argonne, IL (United States); Wesolowski, Kenneth [Argonne National Lab. (ANL), Argonne, IL (United States); Alford, Kurt [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-09-27

    With funding from the National Nuclear Security Administrations Material Management and Minimization Office, Argonne National Laboratory (Argonne) is providing technical assistance to help accelerate the U.S. production of Mo-99 using a non-highly enriched uranium (non-HEU) source. A potential Mo-99 production pathway is by accelerator-initiated fissioning in a subcritical uranyl sulfate solution containing low enriched uranium (LEU). As part of the Argonne development effort, we are undertaking the AMORE (Argonne Molybdenum Research Experiment) project, which is essentially a pilot facility for all phases of Mo-99 production, recovery, and purification. Production of Mo-99 and other fission products in the subcritical target solution is initiated by putting an electron beam on a depleted uranium (DU) target; the fast neutrons produced in the DU target are thermalized and lead to fissioning of U-235. At the end of irradiation, Mo is recovered from the target solution and separated from uranium and most of the fission products by using a titania column. The Mo is stripped from the column with an alkaline solution. After acidification of the Mo product solution from the recovery column, the Mo is concentrated (and further purified) in a second titania column. The strip solution from the concentration column is then purified with the LEU Modified Cintichem process. A full description of the process can be found elsewhere [1–3]. The initial commissioning steps for the AMORE project include performing a Mo-99 spike test with pH 1 sulfuric acid in the target vessel without a beam on the target to demonstrate the initial Mo separation-and-recovery process, followed by the concentration column process. All glovebox operations were tested with cold solutions prior to performing the Mo-99 spike tests. Two Mo-99 spike tests with pH 1 sulfuric acid have been performed to date. Figure 1 shows the flow diagram for the remotely operated Mo-recovery system for the AMORE project

  15. Development, Production and Testing of 4500 Beam Loss Monitors

    CERN Document Server

    Holzer, E B; Dehning, B; Ferioli, G; Grishin, V; Jimenez, T M; Koshelev, A; Kramer, Daniel; Larionov, A; Taborelli, M; Seleznev, V; Sleptsov, M; Sytin, A; Wevers, I

    2008-01-01

    Beam-loss monitoring (BLM) [1] is a key element in the LHC machine protection. 4250 nitrogen filled ionization chambers (IC) and 350 secondary emission monitors (SEM) have been manufactured and tested at the Institute for High Energy Physics (IHEP) in Protvino, Russia, following their development at CERN. Signal speed and robustness against aging were the main design criteria. Each monitor is permanently sealed inside a stainless-steel cylinder. The quality of the welding was a critical aspect during production. The SEMs are requested to hold a vacuum of $10^{-7}$ bar. Impurity levels from thermal and radiationinduced desorption should remain in the range of parts per million in the ICs. To avoid radiation aging (up to $2·10^{8}$ Gy in 20 years) production of the chambers followed strict UHV requirements. IHEP designed and built the UHV production stand. Due to the required dynamic range of $10^{8}$, the leakage current of the monitors has to stay below 2 pA. Several tests during and after production were ...

  16. Combined performance studies for electrons at the 2004 ATLAS combined test-beam

    Science.gov (United States)

    Abat, E.; Abdallah, J. M.; Addy, T. N.; Adragna, P.; Aharrouche, M.; Ahmad, A.; Akesson, T. P. A.; Aleksa, M.; Alexa, C.; Anderson, K.; Andreazza, A.; Anghinolfi, F.; Antonaki, A.; Arabidze, G.; Arik, E.; Atkinson, T.; Baines, J.; Baker, O. K.; Banfi, D.; Baron, S.; Barr, A. J.; Beccherle, R.; Beck, H. P.; Belhorma, B.; Bell, P. J.; Benchekroun, D.; Benjamin, D. P.; Benslama, K.; Bergeaas Kuutmann, E.; Bernabeu, J.; Bertelsen, H.; Binet, S.; Biscarat, C.; Boldea, V.; Bondarenko, V. G.; Boonekamp, M.; Bosman, M.; Bourdarios, C.; Broklova, Z.; Burckhart Chromek, D.; Bychkov, V.; Callahan, J.; Calvet, D.; Canneri, M.; Capeáns Garrido, M.; Caprini, M.; Cardiel Sas, L.; Carli, T.; Carminati, L.; Carvalho, J.; Cascella, M.; Castillo, M. V.; Catinaccio, A.; Cauz, D.; Cavalli, D.; Cavalli Sforza, M.; Cavasinni, V.; Cetin, S. A.; Chen, H.; Cherkaoui, R.; Chevalier, L.; Chevallier, F.; Chouridou, S.; Ciobotaru, M.; Citterio, M.; Clark, A.; Cleland, B.; Cobal, M.; Cogneras, E.; Conde Muino, P.; Consonni, M.; Constantinescu, S.; Cornelissen, T.; Correard, S.; Corso Radu, A.; Costa, G.; Costa, M. J.; Costanzo, D.; Cuneo, S.; Cwetanski, P.; Da Silva, D.; Dam, M.; Dameri, M.; Danielsson, H. O.; Dannheim, D.; Darbo, G.; Davidek, T.; De, K.; Defay, P. O.; Dekhissi, B.; Del Peso, J.; Del Prete, T.; Delmastro, M.; Derue, F.; Di Ciaccio, L.; Di Girolamo, B.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Dobos, D.; Dobson, M.; Dolgoshein, B. A.; Dotti, A.; Drake, G.; Drasal, Z.; Dressnandt, N.; Driouchi, C.; Drohan, J.; Ebenstein, W. L.; Eerola, P.; Efthymiopoulos, I.; Egorov, K.; Eifert, T. F.; Einsweiler, K.; El Kacimi, M.; Elsing, M.; Emelyanov, D.; Escobar, C.; Etienvre, A. I.; Fabich, A.; Facius, K.; Fakhr-Edine, A. I.; Fanti, M.; Farbin, A.; Farthouat, P.; Fassouliotis, D.; Fayard, L.; Febbraro, R.; Fedin, O. L.; Fenyuk, A.; Fergusson, D.; Ferrari, P.; Ferrari, R.; Ferreira, B. C.; Ferrer, A.; Ferrere, D.; Filippini, G.; Flick, T.; Fournier, D.; Francavilla, P.; Francis, D.; Froeschl, R.; Froidevaux, D.; Fullana, E.; Gadomski, S.; Gagliardi, G.; Gagnon, P.; Gallas, M.; Gallop, B. J.; Gameiro, S.; Gan, K. K.; Garcia, R.; Garcia, C.; Gavrilenko, I. L.; Gemme, C.; Gerlach, P.; Ghodbane, N.; Giakoumopoulou, V.; Giangiobbe, V.; Giokaris, N.; Glonti, G.; Goettfert, T.; Golling, T.; Gollub, N.; Gomes, A.; Gomez, M. D.; Gonzalez-Sevilla, S.; Goodrick, M. J.; Gorfine, G.; Gorini, B.; Goujdami, D.; Grahn, K.-J.; Grenier, P.; Grigalashvili, N.; Grishkevich, Y.; Grosse-Knetter, J.; Gruwe, M.; Guicheney, C.; Gupta, A.; Haeberli, C.; Haertel, R.; Hajduk, Z.; Hakobyan, H.; Hance, M.; Hansen, J. D.; Hansen, P. H.; Hara, K.; Harvey, A., Jr.; Hawkings, R. J.; Heinemann, F. E. W.; Henriques Correia, A.; Henss, T.; Hervas, L.; Higon, E.; Hill, J. C.; Hoffman, J.; Hostachy, J. Y.; Hruska, I.; Hubaut, F.; Huegging, F.; Hulsbergen, W.; Hurwitz, M.; Iconomidou-Fayard, L.; Jansen, E.; Jen-La Plante, I.; Johansson, P. D. C.; Jon-And, K.; Joos, M.; Jorgensen, S.; Joseph, J.; Kaczmarska, A.; Kado, M.; Karyukhin, A.; Kataoka, M.; Kayumov, F.; Kazarov, A.; Keener, P. T.; Kekelidze, G. D.; Kerschen, N.; Kersten, S.; Khomich, A.; Khoriauli, G.; Khramov, E.; Khristachev, A.; Khubua, J.; Kittelmann, T. H.; Klingenberg, R.; Klinkby, E. B.; Kodys, P.; Koffas, T.; Kolos, S.; Konovalov, S. P.; Konstantinidis, N.; Kopikov, S.; Korolkov, I.; Kostyukhin, V.; Kovalenko, S.; Kowalski, T. Z.; Krüger, K.; Kramarenko, V.; Kudin, L. G.; Kulchitsky, Y.; Lacasta, C.; Lafaye, R.; Laforge, B.; Lampl, W.; Lanni, F.; Laplace, S.; Lari, T.; Le Bihan, A.-C.; Lechowski, M.; Ledroit-Guillon, F.; Lehmann, G.; Leitner, R.; Lelas, D.; Lester, C. G.; Liang, Z.; Lichard, P.; Liebig, W.; Lipniacka, A.; Lokajicek, M.; Louchard, L.; Lourerio, K. F.; Lucotte, A.; Luehring, F.; Lund-Jensen, B.; Lundberg, B.; Ma, H.; Mackeprang, R.; Maio, A.; Maleev, V. P.; Malek, F.; Mandelli, L.; Maneira, J.; Mangin-Brinet, M.; Manousakis, A.; Mapelli, L.; Marques, C.; Garcia, S. Marti i.; Martin, F.; Mathes, M.; Mazzanti, M.; McFarlane, K. W.; McPherson, R.; Mchedlidze, G.; Mehlhase, S.; Meirosu, C.; Meng, Z.; Meroni, C.; Mialkovski, V.; Mikulec, B.; Milstead, D.; Minashvili, I.; Mindur, B.; Mitsou, V. A.; Moed, S.; Monnier, E.; Moorhead, G.; Morettini, P.; Morozov, S. V.; Mosidze, M.; Mouraviev, S. V.; Moyse, E. W. J.; Munar, A.; Myagkov, A.; Nadtochi, A. V.; Nakamura, K.; Nechaeva, P.; Negri, A.; Nemecek, S.; Nessi, M.; Nesterov, S. Y.; Newcomer, F. M.; Nikitine, I.; Nikolaev, K.; Nikolic-Audit, I.; Ogren, H.; Oh, S. H.; Oleshko, S. B.; Olszowska, J.; Onofre, A.; Padilla Aranda, C.; Paganis, S.; Pallin, D.; Pantea, D.; Paolone, V.; Parodi, F.; Parsons, J.; Parzhitskiy, S.; Pasqualucci, E.; Passmored, S. M.; Pater, J.; Patrichev, S.; Peez, M.; Perez Reale, V.; Perini, L.; Peshekhonov, V. D.; Petersen, J.; Petersen, T. C.; Petti, R.; Phillips, P. W.; Pina, J.; Pinto, B.; Podlyski, F.; Poggioli, L.; Poppleton, A.; Poveda, J.; Pralavorio, P.; Pribyl, L.; Price, M. J.; Prieur, D.; Puigdengoles, C.; Puzo, P.; RØhne, O.; Ragusa, F.; Rajagopalan, S.; Reeves, K.; Reisinger, I.; Rembser, C.; Bruckman de Renstrom, P. A.; Reznicek, P.; Ridel, M.; Risso, P.; Riu, I.; Robinson, D.; Roda, C.; Roe, S.; Rohne, O.; Romaniouk, A.; Rousseau, D.; Rozanov, A.; Ruiz, A.; Rusakovich, N.; Rust, D.; Ryabov, Y. F.; Ryjov, V.; Salto, O.; Salvachua, B.; Salzburger, A.; Sandaker, H.; Santamarina Rios, C.; Santi, L.; Santoni, C.; Saraiva, J. G.; Sarri, F.; Sauvage, G.; Says, L. P.; Schaefer, M.; Schegelsky, V. A.; Schiavi, C.; Schieck, J.; Schlager, G.; Schlereth, J.; Schmitt, C.; Schultes, J.; Schwemling, P.; Schwindling, J.; Seixas, J. M.; Seliverstov, D. M.; Serin, L.; Sfyrla, A.; Shalanda, N.; Shaw, C.; Shin, T.; Shmeleva, A.; Silva, J.; Simion, S.; Simonyan, M.; Sloper, J. E.; Smirnov, S. Yu; Smirnova, L.; Solans, C.; Solodkov, A.; Solovianov, O.; Soloviev, I.; Sosnovtsev, V. V.; Spanò, F.; Speckmayer, P.; Stancu, S.; Stanek, R.; Starchenko, E.; Straessner, A.; Suchkov, S. I.; Suk, M.; Szczygiel, R.; Tarrade, F.; Tartarelli, F.; Tas, P.; Tayalati, Y.; Tegenfeldt, F.; Teuscher, R.; Thioye, M.; Tikhomirov, V. O.; Timmermans, C. J. W. P.; Tisserant, S.; Toczek, B.; Tremblet, L.; Troncon, C.; Tsiareshka, P.; Tyndel, M.; Karagoez Unel, M.; Unal, G.; Unel, G.; Usai, G.; Van Berg, R.; Valero, A.; Valkar, S.; Valls, J. A.; Vandelli, W.; Vannucci, F.; Vartapetian, A.; Vassilakopoulos, V. I.; Vasilyeva, L.; Vazeille, F.; Vernocchi, F.; Vetter-Cole, Y.; Vichou, I.; Vinogradov, V.; Virzi, J.; Vivarelli, I.; de Vivie, J. B.; Volpi, M.; Anh, T. Vu; Wang, C.; Warren, M.; Weber, J.; Weber, M.; Weidberg, A. R.; Weingarten, J.; Wells, P. S.; Werner, P.; Wheeler, S.; Wiessmann, M.; Wilkens, H.; Williams, H. H.; Wingerter-Seez, I.; Yasu, Y.; Zaitsev, A.; Zenin, A.; Zenis, T.; Zenonos, Z.; Zhang, H.; Zhelezko, A.; Zhou, N.

    2010-11-01

    In 2004 at the ATLAS (A Toroidal LHC ApparatuS) combined test beam, one slice of the ATLAS barrel detector (including an Inner Detector set-up and the Liquid Argon calorimeter) was exposed to particles from the H8 SPS beam line at CERN. It was the first occasion to test the combined electron performance of ATLAS. This paper presents results obtained for the momentum measurement p with the Inner Detector and for the performance of the electron measurement with the LAr calorimeter (energy E linearity and resolution) in the presence of a magnetic field in the Inner Detector for momenta ranging from 20 GeV/c to 100 GeV/c. Furthermore the particle identification capabilities of the Transition Radiation Tracker, Bremsstrahlungs-recovery algorithms relying on the LAr calorimeter and results obtained for the E/p ratio and a way how to extract scale parameters will be discussed.

  17. First results of computerised tomographic angiography using electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, K.J.; Weisser, G.; Neff, K.W.; Mai, S.K.; Denk, S.; Georgi, M. [Inst. fuer Klinische Radiologie, Universitaetsklinikum Mannheim, Heidelberg (Germany)

    1999-05-01

    The aim of this study was to evaluate the suitability of electron beam tomography (EBT) with fast continuous volume scanning for CT angiography (CTA) in chest and abdomen. An Evolution XP EBT scanner with a new software version (12.34) was used. One hundred forty images per study can be acquired in 17 s using 3-mm collimation and overlapping image reconstruction. Study protocols for five different clinical applications of EBT CTA were established and evaluated. The EBT CTA technique was performed in 155 patients. High- and homogeneous density values were achieved along the whole course of the vessels; the mean density in the aorta was > 240 HU. Coeliac axis, superior and inferior mesenteric artery, renal and lumbar arteries were visualised in all cases. Maximum intensity projection and shaded surface display reconstruction demonstrated the relation between aneurysm and aortic branches very well due to an excellent resolution along the z-axis. In large scan volumes overlapping image reconstruction demonstrated better resolution along the z-axis than is available with helical CT. The EBT CTA technique proved to be very well suited excellent suitability for evaluation of pulmonary vessels. Compared with helical CT, EBT CTA offers a shorter scan time, which allows higher contrast enhancement in pulmonary vessels. The identification of intraluminal emboli and mural thrombi has improved. The EBT CTA technique is a very reliable tool for evaluation of aortic disease and pulmonary vessels. (orig.) With 3 figs., 9 refs.

  18. Test of the ATLAS pion calibration scheme in the ATLAS combined test beam

    CERN Document Server

    Spanò, F

    2009-01-01

    Pion energy reconstruction is studied using the data collected during the 2004 ATLAS combined test beam. The strategy to extract corrections for the non-compensating nature of the ATLAS calorimeters for dead material losses and for leakage effects is discussed and assessed. The default ATLAS strategy based on a weighting technique of the energy deposits in calorimeter cells is presented and compared to a novel technique exploiting correlations among energy deposited in calorimeter layers.

  19. Using Test Results To Support Clinical Judgment.

    Science.gov (United States)

    Silverman, Linda Kreger

    This paper recommends an evaluation procedure for gifted children which uses test results only to confirm the conclusions resulting from clinical evaluation that involves observation, discussion with the child, an interview with the parents, developmental milestones, and family history. It suggests that traditional test interpretation may lead to…

  20. Fabrication and testing of SMA composite beam with shape control

    Science.gov (United States)

    Noolvi, Basavaraj; S, Raja; Nagaraj, Shanmukha; Mudradi, Varada Raj

    2017-07-01

    Smart materials are the advanced materials that have characteristics of sensing and actuation in response to the external stimuli like pressure, heat or electric charge etc. These materials can be integrated in to any structure to make it smart. From the different types of smart materials available, Shape Memory Alloy (SMA) is found to be more useful in designing new applications, which can offer more actuating speed, reduce the overall weight of the structure. The unique property of SMA is the ability to remember and recover from large strains of upto 8% without permanent deformation. Embedding the SMA wire/sheet in fiber-epoxy/flexible resin systems has many potential applications in Aerospace, Automobile, Medical, Robotics and various other fields. In this work the design, fabrication, and testing of smart SMA composite beam has been carried out. Two types of epoxy based resin systems namely LY 5210 resin system and EPOLAM 2063 resin system are used in fabricating the SMA composite specimens. An appropriate mould is designed and fabricated to retain the pre-strain of SMA wire during high temperature post curing of composite specimens. The specimens are fabricated using vacuum bag technique.

  1. Study of the vertex trigger performance on test-beam data

    CERN Document Server

    Teubert, F

    1999-01-01

    99-030 The performance of the Level-1 vertex trigger algorithm on test-beam data collected with a prototype of the VDET detector is presented. The effect of the detectors misalignment on the Level-1 vertex trigger performance is shown to be a critical issue if the relative position is not controlled better than $100~\\mu$m. The Primary vertex resolution on the longitudinal direction obtained on the test-beam for 2D-tracks ($270~\\mu$m), translates into a resolution close to $80~\\mu$m for the statistics of an LHC event in good agreement with expectations. The discriminating power between B-events and Minimum Bias events is studied using a sample of ``artificial'' events built from events interacting at different targets separated by 1~cm. The results are very encouraging showing the feasibility to trigger on low multiplicity displaced vertices.

  2. Testing Long-Range Beam-Beam Compensation for the LHC Luminosity Upgrade

    CERN Document Server

    Rijoff, T L

    2012-01-01

    The performance of the Large Hadron Collider (LHC) at CERN and its minimum crossing angle are limited by the effect of long-range beam-beam collisions. A wire compensators can mitigate part of the long-range effects and may allow for smaller crossing angles, or higher beam intensity. A prototype long-range wire compensator could be installed in the LHC by 2014/15. Since the originally reserved position for such a wire compensator is not available for this first step, we explore other possible options. Our investigations consider various longitudinal and transverse locations, different wire shapes, different optics configurations and several crossing angles between the two colliding beams. Simulations are carried out with the weak-strong code BBtrack. New postprocessing tools are introduced to analyse tune footprints and particle stability. In particular, a new method for the Lyapunov coefficient calculation is implemented. Submitted as "Tesi di laurea" at the University of Milano, 2012.

  3. PRELIMINARY TEST RESULTS OF A PROTOTYPE FAST KICKER FOR APS MBA UPGRADE

    Energy Technology Data Exchange (ETDEWEB)

    Yao, C.-Y.; Morrison, L.; Sun, X.; Wang, J.; Cours, A.; Westferro, F.; Xiao, A.; Clute, T.; Conway, Z.; Decker, G.; Lenkszus, F.; Carwardine, J.; Barcikowski, A.; Keane, R.; Brill, A.

    2017-06-25

    The APS multi-bend achromatic (MBA) upgrade storage ring plans to support two bunch fill patterns: a 48-bunch and a 324-bunch. A “swap out” injection scheme is required. In order to provide the required kick to injected beam, to minimize the beam loss and residual oscillation of injected beam, and to minimize the perturbation to stored beam during injection, the rise, fall, and flat-top parts of the kicker pulse must be within a 16.9-ns interval. Stripline-type kickers are chosen for both injection and extraction. We developed a prototype kicker that supports a ±15kV differential pulse voltage. We performed high voltage discharge, TDR measurement, high voltage pulse test and beam test of the kicker. We report the final design of the fast kicker and the test results.

  4. Radiotherapy of advanced mycosis fungoides: indications and results of total skin electron beam and photon beam irradiation.

    Science.gov (United States)

    Maingon, P; Truc, G; Dalac, S; Barillot, I; Lambert, D; Petrella, T; Naudy, S; Horiot, J C

    2000-01-01

    The goals of this retrospective study of advanced mycosis fungoides are (1) to describe the indications of a combination of total skin electron beam and photon beam irradiation and (2) to analyze the results of total body or segmental photon irradiation for patients with extension beyond the skin. From January 1975 to December 1995, 45 patients with pathologically-confirmed mycosis fungoides or Sézary syndrome received a combination of TSEB and photon beam irradiation for advanced disease: 34 males and 11 females, mean age 61 years (range 27-87 years). The mean follow-up was 111 months (range 18-244 months, median 85 months). Whole-skin irradiation treatment to a depth of 3-5 mm with a 6-MeV electron beam was produced by a linear accelerator to a total dose of 24-30 Gy in 8-15 fractions, 3-4 times a week. In cases of thick plaques or tumors that were beyond the scope of low energy electron beams or for treating nodal areas (especially in the head and neck area or axilla involvement), regional irradiation (RRT) with Co-60 photon beams was followed by whole-skin electron beam irradiation (15 patients). In cases of diffuse erythrodermia, Sézary syndrome, nodal or visceral involvement, total body irradiation was delivered with a 25-MV photon beam using a split-course regimen to prevent hematological toxicity (22 patients). The first course consisted of 1.25 Gy delivered in ten fractions and 10 days. Subsequently, patients received TSEB. Four to 6 weeks after TSEB, they received a second course of 1.25 Gy. The cumulative TBI dose ranged from 2.5 to 3 Gy in about 3 months. Hemi-body irradiation (HB) with Co-60 (and a bolus) was given in cases of multiple regional tumors with large and thick infiltration of the skin to a dose of 9-12 Gy (using fractions of 1-1.5 Gy/day) which, once flattened, were boosted with whole-skin electron beam therapy (8 patients). At 3 months, the overall response rate was 75% with 23/45 (51%) patients in complete response and 24% in partial

  5. An Innovative Beam Halo Monitor system for the CMS experiment at the LHC: Design, Commissioning and First Beam Results

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00344917; Dabrowski, Anne

    The Compact Muon Solenoid (CMS) is a multi-purpose experiment situated at the Large Hadron Collider (LHC). The CMS has the mandate of searching new physics and making precise measurements of the already known mechanisms by using data produced by collisions of high-energy particles. To ensure high quality physics data taking, it is important to monitor and ensure the quality of the colliding particle beams. This thesis presents the research and design, the integration and the first commissioning results of a novel Beam Halo Monitor (BHM) that was designed and built for the CMS experiment. The BHM provides an online, bunch-by-bunch measurement of background particles created by interactions of the proton beam with residual gas molecules in the vacuum chamber or with collimator material upstream of the CMS, separately for each beam. The system consists of two arrays of twenty direction-sensitive detectors that are distributed azimuthally around the outer forward shielding of the CMS experiment. Each detector is ...

  6. Patients' preferences for receiving laboratory test results.

    Science.gov (United States)

    Sabahi, Azam; Ahmadian, Leila; Mirzaee, Moghadameh; Khajouei, Reza

    2017-04-01

    The laboratory, as a diagnostic department in the hospital, plays an important role in the treatment and prevention of diseases. Paying attention to patients' preferences for communication of test results may provide a better and more responsive system for delivering these results. This study aimed to identify patient preferences regarding receiving their laboratory test results electronically and to identify the reasons behind their choice. Descriptive-analytical study. This study was carried out in 2015 with 200 patients who had access to the internet and had been referred at least once previously to the hospital laboratory department to receive their test results. Data were collected through an expert-validated questionnaire, and its reliability was confirmed by test-retest (P = .8). Data were analyzed using χ2 and marginal independence SPSS and R software. Ninety-eight percent of participants preferred to be notified by short message service when their test results were ready. All participants preferred to receive their test results online, and 82.5% (n = 165) preferred to receive both normal and abnormal test results this way. The main reason for receiving results online was time savings, which was reported by 77% of participants, followed by lowering the chance of missing the results (31%). About 40% of participants thought e-mail notification was more secure than accessing the results through a hospital website. Findings showed that although patients wanted to benefit from online services for receiving their test results, they were concerned about confidentiality and security. Before using online technologies, security measures necessary to protect patient privacy and to gain the trust of patients should be defined.

  7. Analysis of CEDM test results (II)

    Energy Technology Data Exchange (ETDEWEB)

    Jun, H. G.; Chung, C. H.; Choi, N. H.; Yoon, Y. J.; Song, C. H.; Park, J. K. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-02-01

    The performance tests of the control element drive mechanism (CEDM) for the Korean Next Generation Reactor were carried out last year under the reactor operating condition. As parts of the performance test, the endurance performance test was resumed with the same test CEDM motor and continued up to 220 % of the motor design life time travel. The endurance test stopped at 110 % of motor design life time travel (110,000 ft) for inspection and measurement of the CEDM motor components. The test motor was disassembled and inspected, and dimensions of the moving parts on which wear is likely to happen were throughly measured. The endurance performance test continued up to 220,000 ft of the motor travel without any interruption of loop operation caused by malfunction of the test motor reassembled from the previous test run. At the completion of the endurance performance test the motor was fully disassembled and the moving parts of the motor were throughly measured again to find out what amount of the materials was lost by wear during the endurance test. This test results showed that the CEDM motor was successfully operated up to 220,000 ft travel without motor malfunction although some moving parts were damaged by wear and some unidentified causes. 4 refs., 64 figs., 11 tabs. (Author)

  8. A 5000-hour test of a grid-translation beam-deflection system for a 5-cm diameter Kaufman thruster

    Science.gov (United States)

    Lathem, W. C.

    1973-01-01

    A grid-translation type beam deflection system was tested on a 5-cm diameter mercury ion thruster for 5000 hours at a thrust level of about 0.36 mlb. During the first 2000 hours the beam was vectored 10 degrees in one direction. No erosion damage attributable to beam deflection was detected. Results indicate a possible lifetime of 15,000 to 20,000 hours. An optimized neutralizer position was used which eliminated the sputter erosion groove observed on the SERT 2 thrusters.

  9. Initial Results on Neutralized Drift Compression Experiments (NDCX-IA) for High Intensity Ion Beam

    CERN Document Server

    Roy, Prabir K; Baca, David; Bieniosek, Frank; Coleman, Joshua E; Davidson, Ronald C; Efthimion, Philip; Eylon, Shmuel; Gilson, Erik P; Grant Logan, B; Greenway, Wayne; Henestroza, Enrique; Kaganovich, Igor D; Leitner, Matthaeus; Rose, David; Sefkow, Adam; Sharp, William M; Shuman, Derek; Thoma, Carsten H; Vanecek, David; Waldron, William; Welch, Dale; Yu, Simon

    2005-01-01

    Ion beam neutralization and compression experiments are designed to determine the feasibility of using compressed high intensity ion beams for high energy density physics (HEDP) experiments and for inertial fusion power. To quantitatively ascertain the various mechanisms and methods for beam compression, the Neutralized Drift Compression Experiment (NDCX) facility is being constructed at Lawrence Berkeley National Laboratory (LBNL). In the first compression experiment, a 260 KeV, 25 mA, K+ ion beam of centimeters size is radially compressed to a mm size spot by neutralization in a meter-long plasma column and beam peak current is longitudinally compressed by an induction velocity tilt core. Instrumentation, preliminary results of the experiments, and practical limits of compression are presented. These include parameters such as emittance, degree of neutralization, velocity tilt time profile, and accuracy of measurements (fast and spatially high resolution diagnostic) are discussed.

  10. FLEXURAL TESTING OF WOOD-CONCRETE COMPOSITE BEAM MADE FROM KAMPER AND BANGKIRAI WOOD

    Directory of Open Access Journals (Sweden)

    Fengky Satria Yoresta

    2015-07-01

    Full Text Available Certain wood has a tensile strength that almost equal with steel rebar in reinforced concrete beams. This research aims to understand the capacity and flexural behavior of concrete beams reinforced by wood (wood-concrete composite beam. Two different types of beams based on placement positions of wood layers are proposed in this study. Two kinds of wood used are consisted of Bangkirai (Shorea laevifolia and Kamper (Cinnamomum camphora, meanwhile the concrete mix ratio for all beams is 1 cement : 2 fine aggregates : 3 coarse aggregates. Bending test is conducted by using one-point loading method. The results show that composite beam using Bangkirai wood is stronger than beams using Kamper wood. More thicker wood layer in tensile area will increase the flexural strength of beams. Crack patterns identified could be classified into flexural cracks, shear cracks, and split on wood layer   Beberapa jenis kayu tertentu memiliki kekuatan tarik yang hampir sama dengan tulangan baja pada balok beton bertulang. Penelitian ini bertujuan memahami kapasitas dan perilaku lentur balok beton bertulang yang diperkuat menggunakan kayu (balok komposit beton-kayu. Dua tipe balok yang berbeda berdasarkan posisi penempatan kayu digunakan dalam penelitian ini. Dua jenis kayu yang digunakan adalah kayu Bangkirai (Shorea laevifolia and Kamper (Cinnamomum camphora, sementara itu rasio campuran beton untuk semua balok menggunakan perbandingan 1 semen : 2 agregat halus : 3 agregat kasar. Pengujian lentur dilakukan menggunakan metode one-point loading. Hasil penelitian menunjukkan bahwa balok komposit dengan kayu Bangkirai lebih kuat dibandingkan balok dengan kayu Kamper. Semakin tebal lapisan kayu yang berada di daerah tarik akan meningkatkan kekuatan lentur balok. Pola kerusakan yang teridentifikasi dapat diklasifikasikan menjadi retak lentur, retak geser, dan pecah pada kayu REFERENCES Boen T. (2010. Retrofitting Simple Buildings Damaged by Earthquakes. World Seismic

  11. Measurements of electron beam emittance in the Accelerator Test Facility damping ring operated in multibunch modes

    Directory of Open Access Journals (Sweden)

    Yosuke Honda

    2003-09-01

    Full Text Available We present the measurement results of electron beam emittance in the Accelerator Test Facility damping ring operated in multibunch modes. The measurements were carried out with an upgraded laser wire beam profile monitor. The monitor has now a vertical wire as well as a horizontal one and is able to make much faster measurements thanks to an increased effective laser power inside the cavity. The measured emittance shows no large bunch-to-bunch dependence in either the horizontal or vertical directions. The values of the vertical emittance are similar to those obtained in the single-bunch operation. The present results are an important step toward the realization of a high-energy linear collider.

  12. Use of Silicon Carbide as Beam Intercepting Device Material: Tests, Issues and Numerical Simulations

    CERN Document Server

    Delonca, M; Gil Costa, M; Vacca, A

    2014-01-01

    Silicon Carbide (SiC) stands as one of the most promising ceramic material with respect to its thermal shock resistance and mechanical strengths. It has hence been considered as candidate material for the development of higher performance beam intercepting devices at CERN. Its brazing with a metal counterpart has been tested and characterized by means of microstructural and ultrasound techniques. Despite the positive results, its use has to be evaluated with care, due to the strong evidence in literature of large and permanent volumetric expansion, called swelling, under the effect of neutron and ion irradiation. This may cause premature and sudden failure, and can be mitigated to some extent by operating at high temperature. For this reason limited information is available for irradiation below 100°C, which is the typical temperature of interest for beam intercepting devices like dumps or collimators. This paper describes the brazing campaign carried out at CERN, the results, and the theoretical and numeric...

  13. Results from cosmics and first LHC beam with the ALICE HMPID detector

    CERN Document Server

    Volpe, Giacomo

    2009-01-01

    The ALICE HMPID (High Momentum Particle IDentification) detector has been designed to identify charged pions and kaons in the range 1 < p < 3 GeV/c and protons in the range 1.5 < p < 5 GeV/c. It consists of seven identical proximity focusing RICH (Ring Imaging Cherenkov) counters, covering in total 11 m2, which exploit large area MWPC equipped with CsI photocathodes for Cherenkov light imaging emitted in a liquid C6F14 radiator. The ALICE detector has been widely commissioned using cosmics and LHC beam from December 2007 until October 2008. During the cosmics data taking the HMPID detector collected a large set of data, using mainly the trigger provided by the TOF detector. We present here preliminary results of detector alignment using TPC tracking. The HMPID could be operated in a stable way, at a safe HV setting, also during LHC beam injection and circulation tests, when a very large occupancy (up to 50%) was achieved. Resulting gain mapping and overall detector performance will also be discuss...

  14. Thermal control wall prototype and test results

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, M.; Ohshima, K.; Jitsukawa, H.

    1986-01-01

    This paper describes a heat exchanger prototype and test results. The heat exchanger, called a thermal control wall, functions as a skin wall and as a means to vary the exterior wall thermal resistance of a building. Test results confirm that the capacity of the TCW is influenced by solar radiation. Furthermore, this TCW capacity can be evaluated by an overall heat transmission coefficient defined using the same sol air temperature difference as for a conventional wall.

  15. Test beam Characterizations of 3D Silicon Pixel detectors

    CERN Document Server

    Mathes, M; Da Via, C.; Garcia-Sciveres, M.; Einsweiler, K.; Hasi, J.; Kenney, C.; Parker, Sherwood; Reuen, L.; Ruspa, M.; Velthuis, J.; Watts, S.; Wermes, N.

    2008-01-01

    3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders them particularly interesting to be used in environments where standard silicon detectors have limitations, such as for example the radiation environment expected in an LHC upgrade. For the first time, several 3D sensors were assembled as hybrid pixel detectors using the ATLAS-pixel front-end chip and readout electronics. Devices with different electrode configurations have been characterized in a 100 GeV pion beam at the CERN SPS. Here we report results on unirradiated devices with three 3D electrodes per 50 x 400 um2 pixel area. Full charge collection is obtained already with comparatively low bias voltages around 10 V. Spatial resolution with binary readout is obtained as expected from the cell dimensions. Efficiencies of 95.9% +- 0.1 % for tracks parallel to the electrode...

  16. The AMS02 Cherenkov imager prototype In-beam tests with high-energy ions

    CERN Document Server

    Buénerd, Michel

    2005-01-01

    A prototype of the AMS Cherenkov imager has been tested at CERN with 20 and per nucleon ion obtained by fragmentation of a primary beam of Pb and In ions, respectively. Data have been collected with single low-intensity beam settings, over the range of nuclear charges 2beam conditions and using different radiators. The charge Z and velocity β resolution of the prototype have been measured and the aerogel material properties investigated.

  17. Studies of the ATLAS hadronic Calorimeter response to different particles at Test Beams

    CERN Document Server

    Zakareishvili, Tamar; The ATLAS collaboration

    2018-01-01

    The Large Hadron Collider (LHC) Phase II upgrade aims to increase the accelerator luminosity by a factor of 5-10. Due to the expected higher radiation levels and the aging of the current electronics, a new readout system of the ATLAS experiment hadronic calorimeter (TileCal) is needed. A prototype of the upgrade TileCal electronics has been tested using the beam from the Super Proton Synchrotron (SPS) accelerator at CERN. Data were collected with beams of muons, electrons and hadrons at various incident energies and impact angles. The muons data allow to study the dependence of the response on the incident point and angle in the cell. The electron data are used to determine the linearity of the electron energy measurement. The hadron data will allow to tune the calorimeter response to pions and kaons modelling to improve the reconstruction of the jet energies. The results of the ongoing data analysis are discussed in the presentation.

  18. Launch vehicle aerodynamic flight test results

    Science.gov (United States)

    Gaines, L. M.; Osborn, W. L.; Wiltse, P. D.

    1983-01-01

    The aerodynamic flight test procedures and results for the Space Shuttle orbiter are presented. The aerodynamic characteristics used in testing were determined from flights STS-1 and through STS-4. Normal force and pitching moment were different than predicted, suggesting an unanticipated aerodynamic force acting upward on the end of the orbiter. However, lateral-directional aerodynamic characteristics were in good management with good predictions. The flight measured aerodynamics are repeatable and show good correlation with angle of attack and angle of sideslip.

  19. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test...... acknowledgement. Rather, the physicians, trans-ferred work practices from their own departments, which did not have electronic white-boards, to the ED. This finding suggests a challenge to the cross-disciplinary work and norms for how to follow up on blood-test results in the ED....

  20. Ranking schools on external knowledge tests results

    Directory of Open Access Journals (Sweden)

    Gašper Cankar

    2007-01-01

    Full Text Available The paper discusses the use of external knowledge test results for school ranking and the implicit effect of such ranking. A question of validity is raised and a review of research literature and main known problems are presented. In many western countries publication of school results is a common practice and a similar trend can be observed in Slovenia. Experiences of other countries help to predict positive and negative aspects of such publication. Results of external knowledge tests produce very limited information about school quality—if we use other sources of information our ranking of schools can be very different. Nevertheless, external knowledge tests can yield useful information. If we want to improve quality in schools, we must allow schools to use this information themselves and improve from within. Broad public scrutiny is unnecessary and problematic—it moves the focus of school efforts from real improvement of quality to mere improvement of the school public image.

  1. Commissioning status of the decelerator test beam line in CTF3

    CERN Document Server

    Adli, E; Lillestol, R; Olvegaard, M; Syratchev, I; Carrillo, D; Toral, F; Faus-Golfe, A; Garcia-Garrigos, J J; Kubyshin, Y; Montoro, G

    2010-01-01

    The CLIC Test Facility (CTF3) at CERN was constructed by the CTF3 collaboration to study the feasibility of the concepts for a compact linear collider. The test beam line (TBL) recently added to the CTF3 machine was designed to study the CLIC decelerator beam dynamics and 12 GHz power production. The beam line consists of a FODO lattice with high precision BPM’s and quadrupoles on movers for precise beam alignment. A total of 16 Power Extraction and Transfer Structures (PETS) will be installed in between the quadrupoles to extract 12 GHz power from the drive beam provided by the CTF3 machine. The CTF3 drive beam with a bunch-train length of 140 ns, 12 GHz bunch repetition frequency and an average current over the train of up to 28 A will be injected into the test beam line. Each PETS structure will produce 135 MW of 12 GHz power at nominal current. The beam will have lost more than 50 % of its initial energy of 150 MeV at the end of the beam line and will contain particles with energies between 65 MeV and 1...

  2. High energy beam impact tests on a LHC tertiary collimator at the CERN high-radiation to materials facility

    Directory of Open Access Journals (Sweden)

    Marija Cauchi

    2014-02-01

    Full Text Available The correct functioning of a collimation system is crucial to safely operate highly energetic particle accelerators, such as the Large Hadron Collider (LHC. The requirements to handle high intensity beams can be demanding. In this respect, investigating the consequences of LHC particle beams hitting tertiary collimators (TCTs in the experimental regions is a fundamental issue for machine protection. An experimental test was designed to investigate the robustness and effects of beam accidents on a fully assembled collimator, based on accident scenarios in the LHC. This experiment, carried out at the CERN High-Radiation to Materials (HiRadMat facility, involved 440 GeV proton beam impacts of different intensities on the jaws of a horizontal TCT. This paper presents the experimental setup and the preliminary results obtained, together with some first outcomes from visual inspection and a comparison of such results with numerical simulations.

  3. System tests of the LHCb RICH detectors in a charged particle beam

    CERN Document Server

    Skottowe, Hugh

    2009-01-01

    The RICH detectors of the LHCb experiment will provide efficient particle identification over the momentum range 1-100 GeV=c. Results are presented from a beam test of the LHCb RICH system using final production pixel Hybrid Photon Detectors, the final readout electronics and an adapted version of LHCb RICH reconstruction software. Measurements of the photon yields and Cherenkov angle resolutions for both nitrogen and C4F10 radiators agree well with full simulations. The quality of the data and the results obtained demonstrate that all aspects meet the stringent physics requirements of the experiment are now ready for first data.

  4. Results on Intense Beam Focusing and Neutralization from the Neutralized Transport Experiment

    Science.gov (United States)

    Yu, Simon; Anders, Andre; Bieniosek, F. M.; Eylon, Shmuel; Henestroza, Enrique; Roy, Prabir; Shuman, Derek; Waldron, William L.; Houck, Tim; Sharp, William; Rose, Dave; Dale, Welch; Efthimion, Philip; Gilson, Eric; Sefkow, Adam

    2003-10-01

    In heavy ion inertial confinement fusion systems, intense beams of ions must be transported from the exit of the final focus magnet system through the target chamber to hit millimeter spot sizes on the target. Effective plasma neutralization of intense ion beams through the target chamber is essential for the viability of an economically competitive heavy ion fusion power plant. The physics of final magnetic transport and neutralized drift has been studied extensively with PIC simulations. To provide quantitative comparisons of theoretical predictions with experiment, the Heavy Ion Fusion Virtual National Laboratory has completed the construction and has begun experimentation with the NTX (Neutralized Transport Experiment). The experiment consists of 3 phases, each with physics issues of its own. Phase 1 is designed to generate a very high brightness potassium beam with variable perveance, using a beam aperturing technique. Phase 2 consists of magnetic transport through four pulsed quadrupoles. Here, beam tuning as well as the effects of phase space dilution through higher order nonlinear fields must be understood. In Phase 3, a converging ion beam at the exit of the magnetic section is transported through a drift section with plasma sources for beam neutralization, and the final spot size is measured under various conditions of neutralization. In this paper, we present results from all 3 phases of the experiment, with particular emphasis on the neutralization experiments.

  5. Construction and tests of an in-beam PET-like demonstrator for hadrontherapy beam ballistic control

    Energy Technology Data Exchange (ETDEWEB)

    Montarou, G., E-mail: montarou@clermont.in2p3.fr [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Bony, M.; Busato, E.; Chadelas, R. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Donnarieix, D. [Centre Jean Perrin, Service de Physique Médicale, Clermont-Ferrand F-63000 (France); Force, P.; Guicheney, C.; Insa, C.; Lambert, D.; Lestand, L.; Magne, M.; Martin, F. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Millardet, C. [Centre Jean Perrin, Service de Physique Médicale, Clermont-Ferrand F-63000 (France); Nivoix, M.; Podlyski, F.; Rozes, A. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France)

    2017-02-11

    We present the first results obtained with a detector, called Large Area Pixelized Detector (LAPD), dedicated to the study the ballistic control of the beam delivered to the patient by in-beam and real time detection of secondary particles, emitted during its irradiation in the context of hadrontherapy. These particles are 511 keV γ from the annihilation of a positron issued from the β{sup +} emitters induced in the patient tissues along the beam path. The LAPD basic concepts are similar to a conventional PET camera. The 511 keV γ are detected and the reconstructed lines of response allow to measure the β{sup +} activity distribution. Nevertheless, when trying to use γ from positron annihilation for the ballistic control in hadrontherapy, the large prompt γ background should be taken into account and properly rejected. First reconstruction results, obtained with a phantom filled with a high intensity FDG source at the cancer research centre of Clermont-Ferrand are shown. We also report results of measurements performed at the Heidelberg Ion-Beam Therapy Centre with one third of the detector, using proton and carbon ion beams.

  6. Beam Loading Tests on DC-SC Photoinjector at Peking University

    CERN Document Server

    Huang, Senlin; Chu, Xiangqiang; Ding, Yuantao; Hao, Jiankui; Jiao, Fei; Lin, Lin; Lu Xiang Yang; Quan, Shengwen; Wang, Guimei; Wang, Lifang; Xiang Rong; Xiao, Binping; Xie, Datao; Yang Li Min; Zhang, Baocheng; Zhao, Kui; Zhu, Feng

    2004-01-01

    Since the beginning of commissioning in February 2003, lots of tests on the DC-SC photoinjector test facility have been performed. At present, Q0 of the 1+1/2-cell cavity has reached ~1E8 (at 4.2K) and the average gradient was about 4MeV/m. The DC photogun can provide stable electron beams. When the power of output laser went up to 100mW (266nm), the average beam current reached 400μA. Beam loading tests have been carried out, and SC acceleration was achieved. Average current of electron beams is about 100μA after acceleration.Further investigations are in progress to improve diagnostics system and to measure the emittance, energy spread and pulse length of electron beams.

  7. Unit cell sparger test program and preliminary test results

    Energy Technology Data Exchange (ETDEWEB)

    Park, C. K.; Cho, S.; Song, C. H.; Yun, Y. Z.; Jeong, H. Z.; Chon, C. Y. [KAERI, Taejon (Korea, Republic of)

    2001-10-01

    KAERI performs blowdown tests to asess the performance of the prototype sparger which will be used in a APR1400 reactor. This report presents overview of the unit cell sparger test program and results of a preliminary analysis of the data from CPT-3 Test. CPT-3 Test was the third blowdown experiment conducted to determine the influence of air mass in the piping on the IRWST (In-containment Refueling Water Storage Tank) boundary during an operation of Safety Depressurization and Vent System (SDVS). The test was conducted from an initial system pressure of 14.6 MPa, a steam temperature of 343 .deg. C, and an air mass of 3.31 lb. The maximum pressure was observed at the bottom of the IRWST, and the frequency of the pressure wave was less than 6.4 Hz.

  8. Beam Diagnostics Report for the Thermal Test Conducted on 3/9/2016

    Energy Technology Data Exchange (ETDEWEB)

    Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-11

    The thermal test OTR data revealed several issues with the beam focus and the target window itself. The oxidation of the target window and the prominence of a scratch across the center of the window makes it impossible to accurately measure the beam profile and size.

  9. Indeterminate HIV western blot test result.

    Science.gov (United States)

    Barnett, Deborah L; Duffus, Wayne A

    2008-12-01

    An IWB is a test result that creates uncertainty. Explaining this result to patients can cause provider discomfort but the more the provider practices, the comfort level increases. HIV diagnosis is no longer considered a death sentence. It has become a manageable disease when patients enter care early. That is why it is important to encourage screening for all. The earlier a patient is linked to care the better the health outcome and this prevents ongoing HIV transmission.

  10. Cone Penetrometer N Factor Determination Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2014-03-05

    This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to releate resistance measurements taken with the cone penetrometer to shear strength.

  11. Commissioning and First Results of the Electron Beam Profiler in the Main Injector at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Thurman-Keup, R. [Fermilab; Alvarez, M. [Fermilab; Fitzgerald, J. [Fermilab; Lundberg, C. [Fermilab; Prieto, P. [Fermilab; Zagel, J. [Fermilab; Blokland, W. [Oak Ridge

    2017-08-01

    The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. A device such as this is already in use at the Spallation Neutron Source at ORNL and a similar device has been installed in the Main Injector at Fermilab. Commissioning of the device is in progress with the goal of having it operational by the end of the year. The status of the commissioning and initial results will be presented

  12. Experimental Results of Network-Assisted Interference Suppression Scheme Using Adaptive Beam-Tilt Switching

    Directory of Open Access Journals (Sweden)

    Tomoki Murakami

    2017-01-01

    Full Text Available This paper introduces a network-assisted interference suppression scheme using beam-tilt switching per frame for wireless local area network systems and its effectiveness in an actual indoor environment. In the proposed scheme, two access points simultaneously transmit to their own desired station by adjusting angle of beam-tilt including transmit power assisted from network server for the improvement of system throughput. In the conventional researches, it is widely known that beam-tilt is effective for ICI suppression in the outdoor scenario. However, the indoor effectiveness of beam-tilt for ICI suppression has not yet been indicated from the experimental evaluation. Thus, this paper indicates the effectiveness of the proposed scheme by analyzing multiple-input multiple-output channel matrices from experimental measurements in an office environment. The experimental results clearly show that the proposed scheme offers higher system throughput than the conventional scheme using just transmit power control.

  13. First results from the ALICE GEM TPC prototype test

    Energy Technology Data Exchange (ETDEWEB)

    Gasik, Piotr [TU Muenchen, Boltzmannstr. 2, 85748 Garching (Germany); Collaboration: ALICE TPC-Collaboration

    2013-07-01

    A large Time Projection Chamber (TPC) is the main device for tracking and charged particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2018, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 100 above the present readout rate of the TPC. In order to make full use of this luminosity, a major upgrade of the TPC is required. It is foreseen to replace the existing MWPC-based readout with Gas Electron Multiplier (GEM) foils. A GEM TPC can exploit the intrinsic suppression of back-drifting ions from the amplification stage to reduce the problem of drift-field distortions in an ungated operation. The latter is essential for a continuous readout required for all central detectors of ALICE after the upgrade. A prototype of an ALICE Inner Read-Out Chamber (IROC) was equipped with three large-size GEM foils as amplification stage to demonstrate the feasibility of this solution. The GEM IROC was installed within a test field cage with a drift length of 115 mm and commissioned with radioactive sources. The dE/dx resolution of the prototype was evaluated in a test beam campaign using protons, pions and electrons (1 to 6 GeV/c) at the CERN PS. Preliminary results from these measurements are discussed in this contribution.

  14. Influence of Age on Patch Tests Results

    Directory of Open Access Journals (Sweden)

    Aouatef Mahfoudh

    2017-03-01

    Full Text Available Objective: To assess the influence of age on the patch-test results and to compare the profiles of skin sensitizers according to the age groups. Methods: It is an 8-year retrospective study involving entire medical records of the patients with allergic contact dermatitis at the Unity of Dermatology and Allergology in the Department of Occupational Medicine, University Hospital of Sousse in Tunisia. Study population was divided into two age groups (group 1: patients 40 years. The statistical significance level was taken as p<0.05. Results: Among the patients, 586 have had at least one positive reaction to the patch-test. Older individuals were 1.1 times more likely to have at least one positive reaction to the patch-test than younger ones. The most common allergens in both groups are potassium dichromate (34.2% vs. 38%, thiuram mix (6% vs. 11%, cobalt chloride (27% vs. 28.8%, balsam of Peru (6% vs. 11.3% and nickel sulphate (41% vs. 27.3%. A significant variation was noted for potassium dichromate in terms of intensity of skin reaction (p=0.00. Conclusion: More research is needed to elucidate the physiologic mechanisms of age on the patch-test results and to adapt the European Standard Battery to each age group in term of allergen type and their appropriate concentration.

  15. submitter Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    CERN Document Server

    Thomae, R; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V

    2016-01-01

    ABSTRACT At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  16. Cryogenic Semiconductor Detectors: Simulation of Signal Formation & Irradiation Beam Test

    CERN Document Server

    AUTHOR|(CDS)2091318; Stamoulis, G; Vavougios, D

    The Beam Loss Monitoring system of the Large Hadron Collider is responsible for the pro- tection of the machine from damage and for the prevention of a magnet quench. Near the interaction points of the LHC, in the triplet magnets area, the BLMs are sensitive to the collision debris, limiting their ability to distinguish beam loss signal from signal caused due to the collision products. Placing silicon & diamond detectors inside the cold mass of the mag- nets, in liquid helium temperatures, would provide significant improvement to the precision of the measurement of the energy deposition in the superconducting coil of the magnet. To further study the signal formation and the shape of the transient current pulses of the aforementioned detectors in cryogenic temperatures, a simulation application has been developed. The application provides a fast way of determining the electric field components inside the detectors bulk and then introduces an initial charge distribution based on the properties of the radiat...

  17. First results from the Freiburg electron beam ion trap FreEBIT

    Energy Technology Data Exchange (ETDEWEB)

    Crespo Lopez Urrutia, J.R.; Bapat, B.; Feuerstein, B.; Werdich, A.; Ullrich, J. [University of Freiburg, Department of Physics (Germany)

    2000-08-15

    Initial tests from the Freiburg electron beam ion trap are reported. Highly charged ions of xenon, barium, tungsten and krypton have been observed with charge states up to 60+ by means of X-ray spectroscopy. The current status, upgrade and future experiments are outlined.

  18. Field Cone Penetration Tests with Various Penetration Rates - Test Results

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    The test site is located at Nordre Ringgade near the town called Dronninglund in the northern Jutland in Denmark. The site area is relatively flat, and was chosen because it has a size of approximately 3 ha and contains a relatively thick deposit of silty soils. Furthermore the groundwater...... was encountered at approximately 0.2-0.6 m below the ground level. The soil stratigraphy of the test site was before test start identified by geotechnical borings results. The geotechnical borings indicated that the site contains of sandy silt with clay stripes from approx. 4.0 to 10 m. In the top the silty soil...... is very sandy with few clay stripes, and gradually the clay stripes increases wherefore the soil from approx. 10 m contains of clay with sandy silt stripes. Large soil sample was also collected from the test site in order to determine basic soil properties in the laboratory....

  19. Test of the LHC DIAMOND Beam Loss Monitors

    CERN Document Server

    Dehning, B; Effinger, E; Pernegger, H; Griesmayer, E

    2011-01-01

    Chemical Vapour Deposition(CVD) diamond detectors were installed in the collimation area of the CERN LHC to study their feasibility as Fast Beam Loss Monitors in a high-­radiation environment. Four detectors were configured with fast, radiation-­hard pre-amplifiers with a bandwidth of 2GHz. The readout was via an oscilloscope with a bandwidth of 1GHz and a sampling rate of 5 GSPS. Despite the 250m cable run from the detectors to the oscilloscope, particle losses were resolved with a 2ns rise time, a pulse width of 10ns and a time resolution of 615ps. Two modes of operation were applied. For the analysis of unexpected beam aborts, the loss profile was recorded in a 1ms buffer and, for nominal operation, the histogram of the time structure of the losses was recorded in synchronism with the LHC period of 89.2us. Measurements during the LHC start-­up (February to December 2010) are presented. The Diamond Monitors gave an unprecedented insight into the time structure of the beam losses resolving the LHC RF freq...

  20. Test of the photon detection system for the LHCb RICH Upgrade in a charged particle beam

    CERN Document Server

    Baszczyk, Mateusz Karol; Calabrese, Roberto; Cardinale, Roberta; Carniti, Paolo; Cassina, Lorenzo; Cavallero, Giovanni; Cojocariu, Lucian Nicolae; Cotta Ramusino, Angelo; D'Ambrosio, Carmelo; Dorosz, Piotr Andrzej; Easo, Sajan; Eisenhardt, Stephan; Fiorini, Massimiliano; Frei, Christoph; Gambetta, Silvia; Gibson, Valerie; Gotti, Claudio; Harnew, Neville; He, Jibo; Keizer, Floris; Kucewicz, Wojciech; Maciuc, Florin; Maino, Matteo; Malaguti, Roberto; Matteuzzi, Clara; Mccann, Michael Andrew; Morris, Adam; Muheim, Franz; Papanestis, Antonis; Pessina, Gianluigi; Petrolini, Alessandro; Piedigrossi, Didier; Pistone, Alessandro; Placinta, Vlad-Mihai; Sigurdsson, Saevar; Simi, Gabriele; Smith, Jackson William; Spradlin, Patrick; Tomassetti, Luca; Wotton, Stephen

    2016-01-01

    The LHCb detector will be upgraded to use the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov (RICH) detectors are one of the key components of the LHCb detector for particle identification. In this paper, we describe the setup and the results of the first tests in a particle beam carried out to assess prototypes of the upgraded optoelectronic chain from the Multi-Anode PMT photosensor to the readout and data acquisition system.

  1. Test of the photon detection system for the LHCb RICH Upgrade in a charged particle beam

    CERN Document Server

    Baszczyk, M.K.

    2017-01-16

    The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for particle identification. In this paper we describe the setup and the results of tests in a charged particle beam, carried out to assess prototypes of the upgraded opto-electronic chain from the Multi-Anode PMT photosensor to the readout and data acquisition system.

  2. High heat flux test on the thermocouple embedded ITER neutral beam duct liner mock-up

    Energy Technology Data Exchange (ETDEWEB)

    Park, C.K., E-mail: ckpark@nfri.re.kr [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Kim, H.S., E-mail: hskim@nfri.re.kr [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Kim, G.H.; Ahn, H.J. [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Kim, S.K.; Lee, D.W. [Korea Atomic Energy Research Institute, Daejeon 305-353 (Korea, Republic of); Urbani, M. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067, St. Paul Lez Durance, Cedex (France)

    2016-11-01

    Highlights: • Twenty thermocouples have been installed on the NB duct liner full scale mock-up. • High heat flux test has been performed. • Four thermocouple fixation schemes had been verified by high heat flux test. • Temperature behavior of the NB duct liner has been successfully simulated. - Abstract: The ITER neutral beam duct liner is located within the tokamak VV port extension and is mounted on the VV port extension flange. The duct liner is made from CuCrZr copper alloy and is actively cooled through deep-drilled channels. A number of thermocouples should be installed on the neutral beam duct liner in order to provide the ability to detect temperature excursions on the surface of the duct liner. Twenty thermocouples have been installed on the neutral beam duct liner full scale mock-up, and a high heat flux test has been performed at the KoHLT-EB test facility, in order to simulate temperature detection in the neutral beam duct liner during ITER operation. For each thermocouple, the fixation method has been verified by high heat flux test with uniform electron beam profile, and the temperature behavior of the neutral beam duct liner has been successfully simulated by Gaussian electron beam profile.

  3. CLSM bleed water reduction test results

    Energy Technology Data Exchange (ETDEWEB)

    Langton, C.A. [Westinghouse Savannah River Company, Aiken, SC (United States); Rajendran, N. [Bechtel Savannah River Company, Aiken, SC (United States)

    1997-04-21

    Previous testing by BSRI/SRTC/Raytheon indicated that the CLSM specified for the Tank 20 closure generates about 6 gallons (23 liters) of bleed water per cubic yard of material (0.76 m3).1 This amount to about 10 percent of the total mixing water. HLWE requested that the CLSM mix be optimized to reduce bleed water while maintaining flow. Elimination of bleed water from the CLSM mix specified for High-Level Waste Tank Closure will result in waste minimization, time savings and cost savings. Over thirty mixes were formulated and evaluated at the on-site Raytheon Test Laboratory. Improved low bleed water CLSM mixes were identified. Results are documented in this report.

  4. Test Results of the PEFP 3MeV RFQ Upgrade

    CERN Document Server

    Cho, Yong-Sub; Jang, Ji-Ho; Kim, Han-Sung; Kim, Yong-Hwan; Kwon, Hyeok-Jung; Park, Mi-Young; Tae Seol, Kyung

    2005-01-01

    A 3MeV RFQ upgrade for 100MeV proton accelerator has been fabricated at PEFP (Proton Engineering Frontier Project). The tuning of the cavity was carried out before and after the brazing to meet the condition that the quadrupole field profile is within 1% of design value and dipole component is less than 1% of quadrupole one. The ancillary system such as high power RF including klystron power supply and cooling system were already tested up to operating level. Therefore, the main issues of the tests were cavity conditioning up to full power level and low duty beam test. After the completion of the beam test of RFQ itself, the 20MeV DTL which has been tested independently will be carried out. In this paper, the test results of the PEFP 3MeV RFQ upgrade including high power conditioning and low duty beam acceleration are presented.

  5. Polar cap ion beams during periods of northward IMF: Cluster statistical results

    Directory of Open Access Journals (Sweden)

    R. Maggiolo

    2011-05-01

    Full Text Available Above the polar caps and during prolonged periods of northward IMF, the Cluster satellites detect upward accelerated ion beams with energies up to a few keV. They are associated with converging electric field structures indicating that the acceleration is caused by a quasi-static field-aligned electric field that can extend to altitudes higher than 7 RE (Maggiolo et al., 2006; Teste et al., 2007. Using the AMDA science analysis service provided by the Centre de Données de la Physique des Plasmas, we have been able to extract about 200 events of accelerated upgoing ion beams above the polar caps from the Cluster database. Most of these observations are taken at altitudes lower than 7 RE and in the Northern Hemisphere. We investigate the statistical properties of these ion beams. We analyze their geometry, the properties of the plasma populations and of the electric field inside and around the beams, as well as their dependence on solar wind and IMF conditions. We show that ~40 % of the ion beams are collocated with a relatively hot and isotropic plasma population. The density and temperature of the isotropic population are highly variable but suggest that this plasma originates from the plasma sheet. The ion beam properties do not change significantly when the isotropic, hot background population is present. Furthermore, during one single polar cap crossing by Cluster it is possible to detect upgoing ion beams both with and without an accompanying isotropic component. The analysis of the variation of the IMF BZ component prior to the detection of the beams indicates that the delay between a northward/southward turning of IMF and the appearance/disappearance of the beams is respectively ~2 h and 20 min. The observed electrodynamic characteristics of high altitude polar cap ion beams suggest that they are closely connected to polar cap auroral arcs. We discuss the implications of these Cluster observations above the polar cap on the magnetospheric

  6. An improvement in IMRT QA results and beam matching in linacs using statistical process control.

    Science.gov (United States)

    Gagneur, Justin D; Ezzell, Gary A

    2014-09-08

    The purpose of this study is to apply the principles of statistical process control (SPC) in the context of patient specific intensity-modulated radiation therapy (IMRT) QA to set clinic-specific action limits and evaluate the impact of changes to the multileaf collimator (MLC) calibrations on IMRT QA results. Ten months of IMRT QA data with 247 patient QAs collected on three beam-matched linacs were retrospectively analyzed with a focus on the gamma pass rate (GPR) and the average ratio between the measured and planned doses. Initial control charts and action limits were calculated. Based on this data, changes were made to the leaf gap parameter for the MLCs to improve the consistency between linacs. This leaf gap parameter is tested monthly using a MLC sweep test. A follow-up dataset with 424 unique QAs were used to evaluate the impact of the leaf gap parameter change. The initial data average GPR was 98.6% with an SPC action limit of 93.7%. The average ratio of doses was 1.003, with an upper action limit of 1.017 and a lower action limit of 0.989. The sweep test results for the linacs were -1.8%, 0%, and +1.2% from nominal. After the adjustment of the leaf gap parameter, all sweep test results were within 0.4% of nominal. Subsequently, the average GPR was 99.4% with an SPC action limit of 97.3%. The average ratio of doses was 0.997 with an upper action limit of 1.011 and a lower action limit of 0.981. Applying the principles of SPC to IMRT QA allowed small differences between closely matched linacs to be identified and reduced. Ongoing analysis will monitor the process and be used to refine the clinical action limits for IMRT QA.

  7. Calibration of LHCf calorimeters for photon measurement by CERN SPS test beam

    CERN Document Server

    Mase, T; Bonechi, L; Bongi, M; Castellini, G; D'Alessandro, R; Fukui, K; Haguenauer, M; Itow, Y; Kasahara, K; Macina, D; Masuda, K; Menjo, H; Mitsuka, G; Mizuishi, M; Muraki, Y; Nakai, M; Papini, P; Perrot, A-L; Ricciarini, S; Sako, T; Shimizu, Y; Sumi, T; Taki, K; Tamura, T; Torii, S; Tricomi, A; Turner,W C; Viciani, A; Watanabe, H; Yoshida, K

    2012-01-01

    Energy resolution and linearity of the LHCf calorimeters for electromagnetic showers were measured at the SPS H4 beam line in 2007 using electron beams of 50–200 GeV and muon beams of 150 GeV. The absolute energy scale was determined in these data. The results that were obtained (<5% energy resolution) are well understood by using Monte Carlo simulations and are good enough for the requirements of the LHCf experiment.

  8. Photon reconstruction in the ATLAS Inner Detector and Liquid Argon Barrel Calorimeter at the 2004 Combined Test Beam

    CERN Document Server

    Abat, E; Addy, T N; Adragna, P; Aharrouche, M; Ahmad, A; Akesson, T.P A; Aleksa, M; Alexa, C; Anderson, K; Andreazza, A; Anghinolfi, F; Antonaki, A; Arabidze, G; Arik, E; Atkinson, T; Baines, J; Baker, O K; Banfi, D; Baron, S; Barr, A J; Beccherle, R; Beck, H P; Belhorma, B; Bell, P J; Benchekroun, D; Benjamin, D P; Benslama, K; Bergeaas Kuutmann, E; Bernabeu, J; Bertelsen, H; Binet, S; Biscarat, C; Boldea, V; Bondarenko, V G; Boonekamp, M; Bosman, M; Bourdarios, C; Broklova, Z; Burckhart-Chromek, D; Bychkov, V; Callahan, J; Calvet, D; Canneri, M; Capeans Garrido, M; Caprini, M; Cardiel Sas, L; Carli, T; Carminati, L; Carvalho, J; Cascella, M; Castillo, M V; Catinaccio, A; Cauz, D; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Cetin, S A; Chen, H; Cherkaoui, R; Chevalier, L; Chevallier, F; Chouridou, S; Ciobotaru, M; Citterio, M; Clark, A; Cleland, B; Cobal, M; Cogneras, E; Conde Muino, P; Consonni, M; Constantinescu, S; Cornelissen, T; Correard, S; Corso-Radu, A; Costa, G; Costa, M J; Costanzo, D; Cuneo, S; Cwetanski, P; Da Silva, D; Dam, M; Dameri, M; Danielsson, H O; Dannheim, D; Darbo, G; Davidek, T; De, K; Defay, P O; Dekhissi, B; Del Peso, J; Del Prete, T; Delmastro, M; Derue, F; Di Ciaccio, L; Di Girolamo, B; Dita, S; Dittus, F; Djama, F; Djobava, T; Dobos, D; Dobson, M; Dolgoshein, B A; Dotti, A; Drake, G; Drasal, Z; Dressnandt, N; Driouchi, C; Drohan, J; Ebenstein, W L; Eerola, P; Efthymiopoulos, I; Egorov, K; Eifert, T F; Einsweiler, K; El Kacimi, M; Elsing, M; Emelyanov, D; Escobar, C; Etienvre, A I; Fabich, A; Facius, K; Idrissi Fakhr-Eddine, A; Fanti, M; Farbin, A; Farthouat, P; Fassouliotis, D; Fayard, L; Febbraro, R; Fedin, O L; Fenyuk, A; Fergusson, D; Ferrari, P; Ferrari, R; Ferreira, B C; Ferrer, A; Ferrere, D; Filippini, G; Flick, T; Fournier, D; Francavilla, P; Francis, D; Froeschl, R; Froidevaux, D; Fullana, E; Gadomski, S; Gagliardi, G; Gagnon, P; Gallas, M; Gallop, B J; Gameiro, S; Gan, K K; Garcia, R; Garcia, C; Gavrilenko, I L; Gemme, C; Gerlach, P; Ghodbane, N; Giakoumopoulou, V; Giangiobbe, V; Giokaris, N; Glonti, G; Gottfert, T.; Golling, T; Gollub, N; Gomes, A; Gomez, M D; Gonzalez-Sevilla, S; Goodrick, M J; Gorfine, G; Gorini, B; Goujdami, D; Grahn, K J; Grenier, P; Grigalashvili, N; Grishkevich, Y; Grosse-Knetter, J; Gruwe, M; Guicheney, C; Gupta, A; Haeberli, C; Hartel, R.; Hajduk, Z; Hakobyan, H; Hance, M; Hansen, J D; Hansen, P H; Hara, K; Harvey, A., Jr; Hawkings, R J; Heinemann, F.E W; Henriques Correia, A; Henss, T; Hervas, L; Higon, E; Hill, J C; Hoffman, J; Hostachy, J Y; Hruska, I; Hubaut, F; Huegging, F; Hulsbergen, W; Hurwitz, M; Iconomidou-Fayard, L; Jansen, E; Jen-La Plante, I; Johansson, P.D C; Jon-And, K; Joos, M; Jorgensen, S; Joseph, J; Kaczmarska, A; Kado, M; Karyukhin, A; Kataoka, M; Kayumov, F; Kazarov, A; Keener, P T; Kekelidze, G D; Kerschen, N; Kersten, S; Khomich, A; Khoriauli, G; Khramov, E; Khristachev, A; Khubua, J; Kittelmann, T H; Klingenberg, R; Klinkby, E B; Kodys, P; Koffas, T; Kolos, S; Konovalov, S P; Konstantinidis, N; Kopikov, S; Korolkov, I; Kostyukhin, V; Kovalenko, S; Kowalski, T Z; Kruger, K.; Kramarenko, V; Kudin, L G; Kulchitsky, Y; Lacasta, C; Lafaye, R; Laforge, B; Lampl, W; Lanni, F; Laplace, S; Lari, T; Le Bihan, A C; Lechowski, M; Ledroit-Guillon, F; Lehmann, G; Leitner, R; Lelas, D; Lester, C G; Liang, Z; Lichard, P; Liebig, W; Lipniacka, A; Lokajicek, M; Louchard, L; Loureiro, K F; Lucotte, A; Luehring, F; Lund-Jensen, B; Lundberg, B; Ma, H; Mackeprang, R; Maio, A; Maleev, V P; Malek, F; Mandelli, L; Maneira, J; Mangin-Brinet, M; Manousakis, A; Mapelli, L; Marques, C; Marti i Garcia, S; Martin, F; Mathes, M; Mazzanti, M; McFarlane, K W; McPherson, R; Mchedlidze, G; Mehlhase, S; Meirosu, C; Meng, Z; Meroni, C; Mialkovski, V; Mikulec, B; Milstead, D; Minashvili, I; Mindur, B; Mitsou, V A; Moed, S; Monnier, E; Moorhead, G; Morettini, P; Morozov, S V; Mosidze, M; Mouraviev, S V; Moyse, E.W J; Munar, A; Myagkov, A; Nadtochi, A V; Nakamura, K; Nechaeva, P; Negri, A; Nemecek, S; Nessi, M; Nesterov, S Y; Newcomer, F M; Nikitine, I; Nikolaev, K; Nikolic-Audit, I; Ogren, H; Oh, S H; Oleshko, S B; Olszowska, J; Onofre, A; Padilla Aranda, C; Paganis, S; Pallin, D; Pantea, D; Paolone, V; Parodi, F; Parsons, J; Parzhitski, S; Pasqualucci, E; Passmore, S M; Pater, J; Patrichev, S; Peez, M; Perez Reale, V; Perini, L; Peshekhonov, V D; Petersen, J; Petersen, T C; Petti, R; Phillips, P W; Pilcher, J; Pina, J; Pinto, B; Podlyski, F; Poggioli, L; Poppleton, A; Poveda, J; Pralavorio, P; Pribyl, L; Price, M J; Prieur, D; Puigdengoles, C; Puzo, P; Ragusa, F; Rajagopalan, S; Reeves, K; Reisinger, I; Rembser, C; Bruckman de Renstrom, P.A.; Reznicek, P; Ridel, M; Risso, P; Riu, I; Robinson, D; Roda, C; Roe, S; Rohne, O.; Romaniouk, A; Rousseau, D; Rozanov, A; Ruiz, A; Rusakovich, N; Rust, D; Ryabov, Y F; Ryjov, V; Salto, O; Salvachua, B; Salzburger, A; Sandaker, H; Santamarina Rios, C.Santamarina; Santi, L; Santoni, C; Saraiva, J G; Sarri, F; Sauvage, G; Says, L P; Schaefer, M; Schegelsky, V A; Schiavi, C; Schieck, J; Schlager, G; Schlereth, J; Schmitt, C; Schultes, J; Schwemling, P; Schwindling, J; Seixas, J M; Seliverstov, D M; Serin, L; Sfyrla, A; Shalanda, N; Shaw, C; Shin, T; Shmeleva, A; Silva, J; Simion, S; Simonyan, M; Sloper, J E; Smirnov, S.Yu; Smirnova, L; Solans, C; Solodkov, A; Solovianov, O; Soloviev, I; Sosnovtsev, V V; Spano, F; Speckmayer, P; Stancu, S; Stanek, R; Starchenko, E; Straessner, A; Suchkov, S I; Suk, M; Szczygiel, R; Tarrade, F; Tartarelli, F; Tas, P; Tayalati, Y; Tegenfeldt, F; Teuscher, R; Thioye, M; Tikhomirov, V O; Timmermans, C.J.W P; Tisserant, S; Toczek, B; Tremblet, L; Troncon, C; Tsiareshka, P; Tyndel, M; Karagoz Unel, M.; Unal, G; Unel, G; Usai, G; Van Berg, R; Valero, A; Valkar, S; Valls, J A; Vandelli, W; Vannucci, F; Vartapetian, A; Vassilakopoulos, V I; Vasilyeva, L; Vazeille, F; Vernocchi, F; Vetter-Cole, Y; Vichou, I; Vinogradov, V; Virzi, J; Vivarelli, I; de Vivie, J B; Volpi, M; Vu Anh, T; Wang, C; Warren, M; Weber, J; Weber, M; Weidberg, A R; Weingarten, J; Wells, P S; Werner, P; Wheeler, S; Wiesmann, M; Wilkens, H; Williams, H H; Wingerter-Seez, I; Yasu, Y; Zaitsev, A; Zenin, A; Zenis, T; Zenonos, Z; Zhang, H; Zhelezko, A; Zhou, N

    2011-01-01

    The reconstruction of photons in the ATLAS detector is studied with data taken during the 2004 Combined Test Beam, where a full slice of the ATLAS detector was exposed to beams of particles of known energy at the CERN SPS. The results presented show significant differences in the longitudinal development of the electromagnetic shower between converted and unconverted photons as well as in the total measured energy. The potential to use the reconstructed converted photons as a means to precisely map the material of the tracker in front of the electromagnetic calorimeter is also considered. All results obtained are compared with a detailed Monte-Carlo simulation of the test-beam setup which is based on the same simulation and reconstruction tools as those used for the ATLAS detector itself.

  9. Photon reconstruction in the ATLAS Inner Detector and Liquid Argon Barrel Calorimeter at the 2004 Combined Test Beam

    Science.gov (United States)

    Abat, E.; Abdallah, J. M.; Addy, T. N.; Adragna, P.; Aharrouche, M.; Ahmad, A.; Akesson, T. P. A.; Aleksa, M.; Alexa, C.; Anderson, K.; Andreazza, A.; Anghinolfi, F.; Antonaki, A.; Arabidze, G.; Arik, E.; Atkinson, T.; Baines, J.; Baker, O. K.; Banfi, D.; Baron, S.; Barr, A. J.; Beccherle, R.; Beck, H. P.; Belhorma, B.; Bell, P. J.; Benchekroun, D.; Benjamin, D. P.; Benslama, K.; Bergeaas Kuutmann, E.; Bernabeu, J.; Bertelsen, H.; Binet, S.; Biscarat, C.; Boldea, V.; Bondarenko, V. G.; Boonekamp, M.; Bosman, M.; Bourdarios, C.; Broklova, Z.; Burckhart Chromek, D.; Bychkov, V.; Callahan, J.; Calvet, D.; Canneri, M.; Capeáns Garrido, M.; Caprini, M.; Cardiel Sas, L.; Carli, T.; Carminati, L.; Carvalho, J.; Cascella, M.; Castillo, M. V.; Catinaccio, A.; Cauz, D.; Cavalli, D.; Cavalli Sforza, M.; Cavasinni, V.; Cetin, S. A.; Chen, H.; Cherkaoui, R.; Chevalier, L.; Chevallier, F.; Chouridou, S.; Ciobotaru, M.; Citterio, M.; Clark, A.; Cleland, B.; Cobal, M.; Cogneras, E.; Conde Muino, P.; Consonni, M.; Constantinescu, S.; Cornelissen, T.; Correard, S.; Corso Radu, A.; Costa, G.; Costa, M. J.; Costanzo, D.; Cuneo, S.; Cwetanski, P.; Da Silva, D.; Dam, M.; Dameri, M.; Danielsson, H. O.; Dannheim, D.; Darbo, G.; Davidek, T.; De, K.; Defay, P. O.; Dekhissi, B.; Del Peso, J.; Del Prete, T.; Delmastro, M.; Derue, F.; Di Ciaccio, L.; Di Girolamo, B.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Dobos, D.; Dobson, M.; Dolgoshein, B. A.; Dotti, A.; Drake, G.; Drasal, Z.; Dressnandt, N.; Driouchi, C.; Drohan, J.; Ebenstein, W. L.; Eerola, P.; Efthymiopoulos, I.; Egorov, K.; Eifert, T. F.; Einsweiler, K.; El Kacimi, M.; Elsing, M.; Emelyanov, D.; Escobar, C.; Etienvre, A. I.; Fabich, A.; Facius, K.; Fakhr-Edine, A. I.; Fanti, M.; Farbin, A.; Farthouat, P.; Fassouliotis, D.; Fayard, L.; Febbraro, R.; Fedin, O. L.; Fenyuk, A.; Fergusson, D.; Ferrari, P.; Ferrari, R.; Ferreira, B. C.; Ferrer, A.; Ferrere, D.; Filippini, G.; Flick, T.; Fournier, D.; Francavilla, P.; Francis, D.; Froeschl, R.; Froidevaux, D.; Fullana, E.; Gadomski, S.; Gagliardi, G.; Gagnon, P.; Gallas, M.; Gallop, B. J.; Gameiro, S.; Gan, K. K.; Garcia, R.; Garcia, C.; Gavrilenko, I. L.; Gemme, C.; Gerlach, P.; Ghodbane, N.; Giakoumopoulou, V.; Giangiobbe, V.; Giokaris, N.; Glonti, G.; Goettfert, T.; Golling, T.; Gollub, N.; Gomes, A.; Gomez, M. D.; Gonzalez-Sevilla, S.; Goodrick, M. J.; Gorfine, G.; Gorini, B.; Goujdami, D.; Grahn, K.-J.; Grenier, P.; Grigalashvili, N.; Grishkevich, Y.; Grosse-Knetter, J.; Gruwe, M.; Guicheney, C.; Gupta, A.; Haeberli, C.; Haertel, R.; Hajduk, Z.; Hakobyan, H.; Hance, M.; Hansen, J. D.; Hansen, P. H.; Hara, K.; Harvey, A., Jr.; Hawkings, R. J.; Heinemann, F. E. W.; Henriques Correia, A.; Henss, T.; Hervas, L.; Higon, E.; Hill, J. C.; Hoffman, J.; Hostachy, J. Y.; Hruska, I.; Hubaut, F.; Huegging, F.; Hulsbergen, W.; Hurwitz, M.; Iconomidou-Fayard, L.; Jansen, E.; Jen-La Plante, I.; Johansson, P. D. C.; Jon-And, K.; Joos, M.; Jorgensen, S.; Joseph, J.; Kaczmarska, A.; Kado, M.; Karyukhin, A.; Kataoka, M.; Kayumov, F.; Kazarov, A.; Keener, P. T.; Kekelidze, G. D.; Kerschen, N.; Kersten, S.; Khomich, A.; Khoriauli, G.; Khramov, E.; Khristachev, A.; Khubua, J.; Kittelmann, T. H.; Klingenberg, R.; Klinkby, E. B.; Kodys, P.; Koffas, T.; Kolos, S.; Konovalov, S. P.; Konstantinidis, N.; Kopikov, S.; Korolkov, I.; Kostyukhin, V.; Kovalenko, S.; Kowalski, T. Z.; Krüger, K.; Kramarenko, V.; Kudin, L. G.; Kulchitsky, Y.; Lacasta, C.; Lafaye, R.; Laforge, B.; Lampl, W.; Lanni, F.; Laplace, S.; Lari, T.; Le Bihan, A.-C.; Lechowski, M.; Ledroit-Guillon, F.; Lehmann, G.; Leitner, R.; Lelas, D.; Lester, C. G.; Liang, Z.; Lichard, P.; Liebig, W.; Lipniacka, A.; Lokajicek, M.; Louchard, L.; Loureiro, K. F.; Lucotte, A.; Luehring, F.; Lund-Jensen, B.; Lundberg, B.; Ma, H.; Mackeprang, R.; Maio, A.; Maleev, V. P.; Malek, F.; Mandelli, L.; Maneira, J.; Mangin-Brinet, M.; Manousakis, A.; Mapelli, L.; Marques, C.; Garcia, S. Marti i.; Martin, F.; Mathes, M.; Mazzanti, M.; McFarlane, K. W.; McPherson, R.; Mchedlidze, G.; Mehlhase, S.; Meirosu, C.; Meng, Z.; Meroni, C.; Mialkovski, V.; Mikulec, B.; Milstead, D.; Minashvili, I.; Mindur, B.; Mitsou, V. A.; Moed, S.; Monnier, E.; Moorhead, G.; Morettini, P.; Morozov, S. V.; Mosidze, M.; Mouraviev, S. V.; Moyse, E. W. J.; Munar, A.; Myagkov, A.; Nadtochi, A. V.; Nakamura, K.; Nechaeva, P.; Negri, A.; Nemecek, S.; Nessi, M.; Nesterov, S. Y.; Newcomer, F. M.; Nikitine, I.; Nikolaev, K.; Nikolic-Audit, I.; Ogren, H.; Oh, S. H.; Oleshko, S. B.; Olszowska, J.; Onofre, A.; Padilla Aranda, C.; Paganis, S.; Pallin, D.; Pantea, D.; Paolone, V.; Parodi, F.; Parsons, J.; Parzhitskiy, S.; Pasqualucci, E.; Passmored, S. M.; Pater, J.; Patrichev, S.; Peez, M.; Perez Reale, V.; Perini, L.; Peshekhonov, V. D.; Petersen, J.; Petersen, T. C.; Petti, R.; Phillips, P. W.; Pilcher, J.; Pina, J.; Pinto, B.; Podlyski, F.; Poggioli, L.; Poppleton, A.; Poveda, J.; Pralavorio, P.; Pribyl, L.; Price, M. J.; Prieur, D.; Puigdengoles, C.; Puzo, P.; Ragusa, F.; Rajagopalan, S.; Reeves, K.; Reisinger, I.; Rembser, C.; Bruckman de Renstrom, P. A.; Reznicek, P.; Ridel, M.; Risso, P.; Riu, I.; Robinson, D.; Roda, C.; Roe, S.; Røhne, O.; Romaniouk, A.; Rousseau, D.; Rozanov, A.; Ruiz, A.; Rusakovich, N.; Rust, D.; Ryabov, Y. F.; Ryjov, V.; Salto, O.; Salvachua, B.; Salzburger, A.; Sandaker, H.; Santamarina Rios, C.; Santi, L.; Santoni, C.; Saraiva, J. G.; Sarri, F.; Sauvage, G.; Says, L. P.; Schaefer, M.; Schegelsky, V. A.; Schiavi, C.; Schieck, J.; Schlager, G.; Schlereth, J.; Schmitt, C.; Schultes, J.; Schwemling, P.; Schwindling, J.; Seixas, J. M.; Seliverstov, D. M.; Serin, L.; Sfyrla, A.; Shalanda, N.; Shaw, C.; Shin, T.; Shmeleva, A.; Silva, J.; Simion, S.; Simonyan, M.; Sloper, J. E.; Smirnov, S. Yu; Smirnova, L.; Solans, C.; Solodkov, A.; Solovianov, O.; Soloviev, I.; Sosnovtsev, V. V.; Spanò, F.; Speckmayer, P.; Stancu, S.; Stanek, R.; Starchenko, E.; Straessner, A.; Suchkov, S. I.; Suk, M.; Szczygiel, R.; Tarrade, F.; Tartarelli, F.; Tas, P.; Tayalati, Y.; Tegenfeldt, F.; Teuscher, R.; Thioye, M.; Tikhomirov, V. O.; Timmermans, C. J. W. P.; Tisserant, S.; Toczek, B.; Tremblet, L.; Troncon, C.; Tsiareshka, P.; Tyndel, M.; Karagoez Unel, M.; Unal, G.; Unel, G.; Usai, G.; Van Berg, R.; Valero, A.; Valkar, S.; Valls, J. A.; Vandelli, W.; Vannucci, F.; Vartapetian, A.; Vassilakopoulos, V. I.; Vasilyeva, L.; Vazeille, F.; Vernocchi, F.; Vetter-Cole, Y.; Vichou, I.; Vinogradov, V.; Virzi, J.; Vivarelli, I.; de Vivie, J. B.; Volpi, M.; Anh, T. Vu; Wang, C.; Warren, M.; Weber, J.; Weber, M.; Weidberg, A. R.; Weingarten, J.; Wells, P. S.; Werner, P.; Wheeler, S.; Wiessmann, M.; Wilkens, H.; Williams, H. H.; Wingerter-Seez, I.; Yasu, Y.; Zaitsev, A.; Zenin, A.; Zenis, T.; Zenonos, Z.; Zhang, H.; Zhelezko, A.; Zhou, N.

    2011-04-01

    The reconstruction of photons in the ATLAS detector is studied with data taken during the 2004 Combined Test Beam, where a full slice of the ATLAS detector was exposed to beams of particles of known energy at the CERN SPS. The results presented show significant differences in the longitudinal development of the electromagnetic shower between converted and unconverted photons as well as in the total measured energy. The potential to use the reconstructed converted photons as a means to precisely map the material of the tracker in front of the electromagnetic calorimeter is also considered. All results obtained are compared with a detailed Monte-Carlo simulation of the test-beam setup which is based on the same simulation and reconstruction tools as those used for the ATLAS detector itself.

  10. Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

    Energy Technology Data Exchange (ETDEWEB)

    Antoni, V.; Agostinetti, P.; Brombin, M.; Cervaro, V.; Delogu, R.; Fasolo, D.; Franchin, L.; Ghiraldelli, R.; Molon, F.; Pasqualotto, R.; Serianni, G., E-mail: gianluigi.serianni@igi.cnr.it; Tollin, M.; Veltri, P. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) (Italy); De Muri, M. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) (Italy); INFN-LNL, v.le dell' Università 2, I-35020, Legnaro (PD) Italy (Italy); Ikeda, K.; Kisaki, M.; Nakano, H.; Takeiri, Y.; Tsumori, K. [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Muraro, A. [Istituto di Fisica del Plasma (IFP-CNR) – Via Cozzi 53, 20125, Milano (Italy)

    2015-04-08

    In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

  11. An evaluation testing technique of single event effect using Beam Blanking SEM

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, J.; Hada, T.; Pesce, A.; Akutsu, T.; Matsuda, S. [National Space Development Agency of Japan, Tsukuba, Ibaraki (Japan). Tsukuba Space Center; Igarashi, T.; Baba, S.

    1997-03-01

    Beam Blanking SEM (Scanning Electron Microscope) testing technique has been applied to CMOS SRAM devices to evaluate the occurence of soft errors on memory cells. Cross-section versus beam current and LET curves derived from BBSEM and heavy ion testing technique, respectively, have been compared. A linear relation between BBSEM current and heavy ion LET has been found. The purpose of this study was to demonstrate that the application of focused pulsed electron beam could be a reliable, convenient and inexpensive tool to investigate the effects of heavy ions and high energy particles on memory devices for space application. (author)

  12. Summary and Conclusions of the First DESY Test Beam User Workshop arXiv

    CERN Document Server

    Arling, Jan-Hendrik; Bandiera, Laura; Behnke, Ties; Dannheim, Dominik; Diener, Ralf; Dreyling-Eschweiler, Jan; Ehrlichmann, Heiko; Gerbershagen, Andreas; Gregor, Ingrid-Maria; Hayrapetyan, Avetik; Kaminski, Jochen; Kroll, Jiri; Martinengo, Paolo; Meyners, Norbert; Müntz, Christian; Poley, Luise; Schwenker, Benjamin; Stanitzki, Marcel

    On October 5/6, 2017, DESY hosted the first DESY Test Beam User Workshop [1] which took place in Hamburg. Fifty participants from different user communities, ranging from LHC (ALICE, ATLAS, CMS, LHCb) to FAIR (CBM, PANDA), DUNE, Belle-II, future linear colliders (ILC, CLIC) and generic detector R&D presented their experiences with the DESY II Test Beam Facility, their concrete plans for the upcoming years and a first estimate of their needs for beam time in the long-term future beyond 2025. A special focus was also on additional improvements to the facility beyond its current capabilities.

  13. Test Results of a MSGC Detector Module for the CMS forward MSGC-Tracker

    CERN Document Server

    Kräber, Michael; Kärcher, Kurt; Knoblauch, Dieter; Metri, R; Müller, Thomas; Neuberger, Dirk; Pallarès, Anne; Simonis, Hans-Jürgen; Thümmel, Wolf Hagen

    1998-01-01

    We report on the construction and test beam results of a MSGC detector module with four trapezoidal elements arranged in a geometry as planned for the CMS forward tracker. Our objective is to study a concept for the forward detector modules which is easy to build with minimal contribution to the material budget. Signal to noise ratio and spatial resolution of the detector are studied for different bias voltages in a 100 GeV muon beam at CERN.

  14. Residual Stress Test and Finite Element Analysis of Titanium Alloy Surface Obtained by Electron Beam Welding

    Directory of Open Access Journals (Sweden)

    LIU Xiaojia

    2016-08-01

    Full Text Available Ti60 titanium alloy plates were welded by electron beam,and the welding residual stress was tested and simulated by the residual stress tester and finite element analysis. The comparison of the residual stress values caused in the three kinds of welding processes of pre-heating, slow cooling and both pre-heating and slow cooling was carried out. The residual stress distribution law was also studied. Results show that in the vertical welding section, the longitudinal welding residual stress tested is similar to that simulated as to the change trend; in the parallel welding section, the distributions of the tested and simulated longitudinal welding residual stress are similar. These prove that the finite element analysis is reasonable and reliable. The process of pre-heating has little influence on the welding residual stress, but the slow cooling process can change its distribution.

  15. Numerical simulation and optimization of the variable energy 60-1000 MeV proton beams at PNPI synchrocyclotron for testing the radiation resistance of electronics

    Science.gov (United States)

    Artamonov, S. A.; Ivanov, E. M.; Ivanov, N. A.; Lebedeva, J. S.; Riabov, G. A.

    2017-01-01

    A universal center for testing electronic components (ECs) for the needs of aviation and space is created in the SC-1000 Petersburg Nuclear Physics Institute, National Research Centre "Kurchatov Institute" (PNPI NRC KI). One of the main instruments of these tests is variable energy protons beams. This paper presents Monte Carlo simulation results for a proton beam with energy of 1000 MeV passing through copper and tungsten degraders, and defines the length of these degraders to obtain energies of 60, 100, 200, 300, 400, 500, 600, 700, 800, 900, and 1000 MeV. Detailed studies of further transmission of the proton beams along the beam line using the copper degrader are accomplished. Basic theoretical parameters for each proton beam, such as the intensity, the energy heterogeneity, beam size, and uniformity of its spatial distribution are obtained.

  16. Visual perception skills testing: preliminary results

    CSIR Research Space (South Africa)

    Smith, Adrew C

    2009-02-01

    Full Text Available stream_source_info Smith_d4_2009.pdf.txt stream_content_type text/plain stream_size 7318 Content-Encoding UTF-8 stream_name Smith_d4_2009.pdf.txt Content-Type text/plain; charset=UTF-8 Visual Perception Skills Testing...: Preliminary Results Andrew Cyrus Smith CSIR Meraka Institute PO Box 395 Pretoria, 0001, South Africa +27 12 841 4626 acsmith @ csir.co.za ABSTRACT Good visual perception skills are important in the effective manipulation of Tangible User...

  17. Arc melter demonstration baseline test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process.

  18. Preliminary test results for the SVX4

    Energy Technology Data Exchange (ETDEWEB)

    Christofek, L.; Hanagaki, K.; Rapidis, P.; Utes, M.; /Fermilab

    2005-06-01

    We present and summarize the preliminary test results for SVX4 chip testing. There are presently two versions of the SVX4. Version 2 has on-chip bypassing and Version 1 does not. The on-chip bypassing is a layer of transistors under the front-end analog pipeline that acts as a bypassing capacitor for the voltage supply. Its size is about a microfarad. We aggressively choose to test Version 2 because of this feature. The feature is advantageous for hybrid design because it eliminates the need for an additional passive component on the hybrid itself by placing it on the actual SVX4 die. Also, the SVX4 was designed to operate in two modes: D. and CDF. One can set which mode the chip will operate by placing a jumper in the proper position on the SVX4 chip carrier. In either mode, the chip can either use the operating parameters from the shift register or the shadow register. Similarly, this is selected by placing a jumper on the SVX4 chip carrier. This chip has this feature because it was unknown whether the new design of the shadow register would be operable. The shadow register is also call the SEU register or Single Event Upset register. An introduction into the functionality of the chip and an explanation on the difference between D. and CDF mode can be found in the SVX4 User's Manual [1].

  19. Reanimation of the RICH Test Beam Simulation in GEANT4

    CERN Document Server

    Arzymatov, Kenenbek

    2017-01-01

    This test was originally developed by Sajan Easo (LHCb) ten years ago mostly for the purpose of testing the behavior of photomultipliers, but it wasn’t used in regression testing in Gauss/Geant4 famework. The goal of project is to revive simulation of cherenkov radiaton test by completing.

  20. First beam test of a combined ramp and squeeze at LHC

    CERN Document Server

    Wenninger, Jorg; Coello De Portugal - Martinez Vazquez, Jaime Maria; Gorzawski, Arkadiusz; Redaelli, Stefano; Schaumann, Michaela; Solfaroli Camillocci, Matteo; CERN. Geneva. ATS Department

    2015-01-01

    With increasing maturity of LHC operation it is possible to envisage more complex beam manipulations. At the same time operational efficiency receives increasing attention. So far ramping the beams to their target energy and squeezing the beams to smaller or higher beta are decoupled at the LHC. (De-)squeezing is always performed at the target energy, currently 6.5 TeV. Studies to combine the ramp and squeeze processes have been made for the LHC since 2011, but so far no experimental test with beam had ever performed. This note describes the first machine experiment with beam aiming at validating the combination of ramp and squeeze, the so-called combined ramp and squeeze (CRS).

  1. Test bench to commission a third ion source beam line and a newly designed extraction system

    Energy Technology Data Exchange (ETDEWEB)

    Winkelmann, T.; Cee, R.; Haberer, T.; Naas, B.; Peters, A. [Heidelberger Ionenstrahl-Therapie Centrum (HIT), D-69120 Heidelberg (Germany)

    2012-02-15

    The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

  2. Test bench to commission a third ion source beam line and a newly designed extraction system.

    Science.gov (United States)

    Winkelmann, T; Cee, R; Haberer, T; Naas, B; Peters, A

    2012-02-01

    The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

  3. Influence of steel fibers on the shear and flexural performance of high-strength concrete beams tested under blast loads

    Science.gov (United States)

    Algassem, O.; Li, Y.; Aoude, H.

    2017-09-01

    This paper presents the results of a study examining the effect of steel fibres on the blast behaviour of high-strength concrete beams. As part of the study, a series of three large-scale beams built with high-strength concrete and steel fibres are tested under simulated blast loading using the shock-tube testing facility at the University of Ottawa. The specimens include two beams built with conventional high-strength concrete (HSC) and one beam built with high-strength concrete and steel fibres (HSFRC). The effect of steel fibres on the blast behaviour is examined by comparing the failure mode, mid-span displacements and, overall blast resistance of the specimens. The results show that the addition of steel fibres in high-strength concrete beams can prevent shear failure and substitute for shear reinforcement if added in sufficient quantity. Moreover, the use of steel fibres improves flexural response under blast loading by reducing displacements and increasing blast capacity. Finally, the provision of steel fibres is found to improve the fragmentation resistance of high-strength concrete under blast loads.

  4. Non-linear beam dynamics tests in the LHC: measurement of intensity decay for probing dynamic aperture at injection

    CERN Document Server

    Cettour Cave, S; Giovannozzi, M; Ludwig, M; MacPherson, A; Redaelli, S; Roncarolo, F; Solfaroli Camillocci, M; Venturini Delsolaro, W

    2013-01-01

    For a second year in a row dynamic aperture experiments have been performed at the LHC. These studies have been carried out by two teams following alternative techniques: On Beam 1 a novel approach has been tested which heats the beam until the emittance becomes large, and derives the dynamic aperture from beam losses assuming an inverse logarithm model for the time-dependence of the intensity. On Beam 2, the traditional approach of sampling the dynamic aperture with large amplitude kicks has been pursued [1]. In 2011, considerable progress was made and impressive results have been reported. In 2012 a further Machine Development (MD) session was scheduled during which both teams have benefited from an improved availability of the beams and more optimal performance of the instrumentation. Observations and analysis are presented as two MD reports of the LHC dynamic aperture experiment MD. This note describes the observations made on Beam 1, when the strength of the spool pieces have been varied. The key quantit...

  5. Unit cell sparger test program and analysis of test results

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Kyung; Song, C. H.; Cho, S.; Yoon, Y. J

    2003-11-01

    This report presents the results of test data from CPT-3 test and the effect of important parameters on the IRWST load. The object of CPT-3 test is to determine the influence of air mass in the piping on the IRWST (In-containment Refueling Water Storage Tank) boundary during an operation of Safety Depressurization and Vent System (SDVS). The test was conducted from an initial system pressure of 15.2 MPa, a steam temperature of 343.3 .deg. C, and an air mass of 3.34 lb. Following valve actuation, the pressure within the discharge line underwent pressure transient due to high pressure steam from the pressurizer and the discharged high pressure air formed air bubbles, which expanded and compressed periodically in the simulated IRWST. Air bubble oscillation was terminated within 2 s into the test. The magnitude of the pressure wave during the air clearing period was inversely proportional to the distance and very abrupt pressure spikes were observed in case the distance from the sparger holes to the submerged structure was less than 0.9 m. After the isolation valves were closed, the water in the simulated IRWST was considered to rise up to the 2.4m from the water surface in the quench tank. The amount of air mass in the piping, water temperature in the simulated IRWST, air temperature in the piping had not significant effect on the pressure loading during an air clearing period. However, the opening time of the isolation valve, steam mass flow rate, and submergence of an sparger have been shown to have great effects on the pressure loading during an air clearing period. 2 % of sparger flow area seems to be sufficient for the vacuum breaker area to mitigate the water hammering caused by abrupt water level rising during valve closure.

  6. Interface Fracture Toughness Assessment of Solder Joints Using Double Cantilever Beam Test

    Science.gov (United States)

    Loo, Shane Zhi Yuan; Lee, Puay Cheng; Lim, Zan Xuan; Yantara, Natalia; Tee, Tong Yan; Tan, Cher Ming; Chen, Zhong

    In the current work, a test scheme to evaluate solder joint interface fracture toughness using double cantilever beam (DCB) test has been successfully demonstrated. The obtained results, in terms of critical energy release rate, predict the joint failure based on the principle of fracture mechanics. The results can be used as a materials property in the reliability design of various types of solder-ball joined packages. DCB specimens made of 99.9 wt% copper were selected in the current work. Eutectic Sn-37Pb and lead-free Sn-3.5Ag-0.5Cu solders were used to join two pieces of the copper beams with controlled solder thickness. The test record showed steady propagation of the crack along the solder / copper interface, which verifies the viability of such a testing scheme. Interface fracture toughness for as-joined, extensively-reflowed and thermally aged samples has been measured. Both the reflow treatment and the thermal aging lead to degradation of the solder joint fracture resistance. Reflow treatment was more damaging as it induces much faster interface reaction. Fractographic analysis established that the fracture has a mixed micromechanism of dimple and cleavage. The dimples are formed as a result of the separation between the hard intermetallic compound (IMC) particles and the soft solder material, while the cleavage is formed by the brittle split of the IMCs. When the IMC thickness is increased due to extended interface reaction, the proportion of IMC cleavage failure increases, and this was reflected in the decrease of the critical energy release rate.

  7. Initial Burn Pan (JMTF) Testing Results

    Science.gov (United States)

    2016-03-01

    12  Figure 14. Test 1 - Data from underwater thermocouples... underwater thermocouples. ............................................................................ 18  LIST OF TABLES Table 1. Test schedule...locations around the test area. A remote control drone equipped with a GoPro camera was also used to video the third test. All recorded video and still

  8. Protecting LHC Components Against Radiation Resulting From an Unsynchronized Beam Abort

    CERN Document Server

    Drozhdin, A I; Mokhov, N V; Rakhno, I L; Weisse, E

    2001-01-01

    The effect of possible accidental beam loss in the LHC on the IP5 and IP6 insertion elements is studied via realistic Monte Carlo simulations. The scenario studied is beam loss due to unsynchronized abort at an accidental prefire of one of the abort kicker modules. Simulations show that this beam loss would result in severe heating of the IP5 and IP6 superconducting (SC) quadrupoles. Contrary to the previous considerations with a stationary set of collimators in IP5, collimators in IP6 close to the cause are proposed: a movable collimator upstream of the Q4 quadrupole and a stationary one upstream of the extraction septum MSD. The calculated temperature rise in the optimal set of collimators is quite acceptable. All SC magnets are protected by these collimators against damage.

  9. CFRP strengthening of concrete beams - testing in sub-zero temperature

    DEFF Research Database (Denmark)

    Täljsten, Björn; Carolin, A.

    2007-01-01

    Strengthening structures with epoxy bonded Carbon Fibre-Reinforced Polymer (CFRP) plates and sheets are today a well-known and over the world common used method to improve a structure performance. The composite materials used for strengthening are very light and easy to handle,. have good...... compared to the summer period? In this paper the last issue will be addressed. CFRP strengthen concrete beams have been tested in sub-zero temperature and loaded up to failure. The cold climate tests are then compared with similar beams tested in room climate. From the tests no significantly difference...

  10. Advanced wing design survivability testing and results

    Science.gov (United States)

    Bruno, J.; Tobias, M.

    1992-01-01

    Composite wings on current operational aircraft are conservatively designed to account for stress/strain concentrations, and to assure specified damage tolerance. The technology that can lead to improved composite wing structures and associated structural efficiency is to increase design ultimate strain levels beyond their current limit of 3500 to 4000 micro-in/in to 6000 micro-in/in without sacrificing structural integrity, durability, damage tolerance, or survivability. Grumman, under the sponsorship of the Naval Air Development Center (NADC), has developed a high-strain composite wing design for a subsonic aircraft wing using novel and innovative design concepts and manufacturing methods, while maintaining a state-of-the-art fiber/resin system. The current advanced wing design effort addressed a tactical subsonic aircraft wing using previously developed, high-strain wing design concepts in conjunction with newer/emerging fiber and polymer matrix composite (PMC) materials to achieve the same goals, while reducing complexity. Two categories of advanced PMC materials were evaluated: toughened thermosets; and engineered thermoplastics. Advanced PMC materials offer the technological opportunity to take maximum advantage of improved material properties, physical characteristics, and tailorability to increase performance and survivability over current composite structure. Damage tolerance and survivability to various threats, in addition to structural integrity and durability, were key technical issues addressed during this study, and evaluated through test. This paper focuses on the live-fire testing, and the results performed to experimentally evaluate the survivability of the advanced wing design.

  11. Trillium 360 Seismometer Initial Test Results

    Science.gov (United States)

    Bainbridge, Geoffrey; Devanney, Peter; Upadhyaya, Sarvesh

    2017-04-01

    Test results for Trillium 360 show this seismometer can resolve the Peterson New Low Noise Model down to 300 seconds period. This has been confirmed at multiple sites: Pinon Flat (California), Albuquerque Seismological Laboratory (New Mexico) and Nanometrics (Ottawa, Canada). The Pinon Flat deployment captured the March 2, 2016 Mw=7.9 Indonesian event and showed a response coherent with reference sensors including an STS-1 at periods down to 0.0015 Hz. At frequencies below 0.0015 Hz the reference sensors showed a noncoherent spurious response, i.e. noise in the presence of signal, whereas the Trillium 360 was relatively unaffected. Magnetic sensitivity has been measured to be 0.01 m/s^2/T in two independent tests at ASL and Nanometrics. Temperature sensitivity is 3*10^-4 m/s^2/T. This combination of low sensitivity to both magnetic field and temperature is achieved through magnetic shielding which resolves the side effect of magnetic sensitivity in temperature-compensated ferromagnetic spring alloys. The T360 seismometer components are sufficiently miniaturized for deployment in a borehole. This enables low-noise performance even in an urban environment with thick sediments (at Nanometrics, Ottawa) since the seismometer can be emplaced in bedrock below surface sediments and away from surface noise.

  12. Initial imperfections for fea of tubular beams based on validated experiment results

    NARCIS (Netherlands)

    Pavlovic, M.; Veljkovic, M.; Dubina, D.; Ungureanu, V.

    2016-01-01

    The experiment data available on 4-point bending experiments performed in Aus-tralia and Europe on tubular section beams are validated by FEA. Large scattering of available experiment results is investigated by detailed analysis of different geometrical imperfections. Loading set-up is analysed

  13. Beam Test of a Dielectric Loaded High Pressure RF Cavity for Use in Muon Cooling Channels

    Energy Technology Data Exchange (ETDEWEB)

    Freemire, Ben [IIT, Chicago; Bowring, Daniel [Fermilab; Kochemirovskiy, Alexey [Chicago U.; Moretti, Alfred [Fermilab; Peterson, David [Fermilab; Tollestrup, Alvin [Fermilab; Torun, Yagmur [IIT, Chicago; Yonehara, Katsuya [Fermilab

    2016-06-01

    Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. A 99.5% alumina ring was inserted in a high pressure RF test cell and subjected to an intense proton beam at the MuCool Test Area at Fermilab. The results of the performance of this dielectric loaded high pressure RF cavity will be presented.

  14. Analysis of CEDM test result(1)

    Energy Technology Data Exchange (ETDEWEB)

    Jun, H. G.; Chung, C. H.; Yoon, Y. J.; Donh, C. H.; Park, J. K. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-05-01

    The performance tests of the control element drive mechanism (CEDM) of Korean Next Generation Reactor(KNGR) were carried out. The performance tests consist of endurance test, power test, air cooling test and drop test. The endurance test was carried out to get 500,650 steps (31,290.6 ft) of CEDM movement. In power test, the motor driving power was measured for the cases of withdrawl, inserting, and holding states of CEDM. In air cooling test, the power to move the CEA was calculated from the measurements of temperature rising of air and it was compared with the measurement of power test. The 678 times of the drop test were carried out. For all drop tests, the drop time was shorter than the acceptance criteria of 4 sec. The effects of loop temperature and flow rate were investigated in drop test. After endurance test, the CEDM assembly was disassembled and visually inspected, and it was found out that the motor are not injured, bur the drive shaft is damaged seriously. 3 refs., 34 figs., 17 tabs. (Author)

  15. Development of a synchrotron radiation beam monitor for the Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Scarpelli, Andrea [Univ. of Ferrara (Italy)

    2016-01-01

    Nonlinear integrable optics applied to beam dynamics may mitigate multi-particle instabilities, but proof of principle experiments have never been carried out. The Integrable Optics Test Accelerator (IOTA) is an electron and proton storage ring currently being built at Fermilab, which addresses tests of nonlinear lattice elements in a real machine in addition to experiments on optical stochastic cooling and on the single-electron wave function. These experiments require an outstanding control over the lattice parameters, achievable with fast and precise beam monitoring systems. This work describes the steps for designing and building a beam monitor for IOTA based on synchrotron radiation, able to measure intensity, position and transverse cross-section beam.

  16. The thermal focusing mirror of the ESRF Troika beam line principle, design and first results

    CERN Document Server

    Mattenet, M; Zontone, F; Detlefs, C; Grübel, G; Facchini, M; Jacquot, P

    2001-01-01

    We describe a focussing mirror system that is bent by differential thermal expansion due to a temperature gradient perpendicular to its surface. Temperature control is achieved through a side cooling arrangement on the top, and a heating device at the bottom of the mirror body. We present measurements of the optical properties obtained by speckle interferometry on a test system, and under actual operating conditions in the white undulator beam.

  17. Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data

    CERN Document Server

    Chatrchyan, S; Sirunyan, A M; Adam, W; Arnold, B; Bergauer, H; Bergauer, T; Dragicevic, M; Eichberger, M; Erö, J; Friedl, M; Frühwirth, R; Ghete, V M; Hammer, J; Hänsel, S; Hoch, M; Hörmann, N; Hrubec, J; Jeitler, M; Kasieczka, G; Kastner, K; Krammer, M; Liko, D; Magrans de Abril, I; Mikulec, I; Mittermayr, F; Neuherz, B; Oberegger, M; Padrta, M; Pernicka, M; Rohringer, H; Schmid, S; Schöfbeck, R; Schreiner, T; Stark, R; Steininger, H; Strauss, J; Taurok, A; Teischinger, F; Themel, T; Uhl, D; Wagner, P; Waltenberger, W; Walzel, G; Widl, E; Wulz, C E; Chekhovsky, V; Dvornikov, O; Emeliantchik, I; Litomin, A; Makarenko, V; Marfin, I; Mossolov, V; Shumeiko, N; Solin, A; Stefanovitch, R; Suarez Gonzalez, J; Tikhonov, A; Fedorov, A; Karneyeu, A; Korzhik, M; Panov, V; Zuyeuski, R; Kuchinsky, P; Beaumont, W; Benucci, L; Cardaci, M; De Wolf, E A; Delmeire, E; Druzhkin, D; Hashemi, M; Janssen, X; Maes, T; Mucibello, L; Ochesanu, S; Rougny, R; Selvaggi, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Adler, V; Beauceron, S; Blyweert, S; D'Hondt, J; De Weirdt, S; Devroede, O; Heyninck, J; Kalogeropoulos, A; Maes, J; Maes, M; Mozer, M U; Tavernier, S; Van Doninck, W; Van Mulders, P; Villella, I; Bouhali, O; Chabert, E C; Charaf, O; Clerbaux, B; De Lentdecker, G; Dero, V; Elgammal, S; Gay, A P R; Hammad, G H; Marage, P E; Rugovac, S; Vander Velde, C; Vanlaer, P; Wickens, J; Grunewald, M; Klein, B; Marinov, A; Ryckbosch, D; Thyssen, F; Tytgat, M; Vanelderen, L; Verwilligen, P; Basegmez, S; Bruno, G; Caudron, J; Delaere, C; Demin, P; Favart, D; Giammanco, A; Grégoire, G; Lemaitre, V; Militaru, O; Ovyn, S; Piotrzkowski, K; Quertenmont, L; Schul, N; Beliy, N; Daubie, E; Alves, G A; Pol, M E; Souza, M H G; Carvalho, W; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Mundim, L; Oguri, V; Santoro, A; Silva Do Amaral, S M; Sznajder, A; Fernandez Perez Tomei, T R; Ferreira Dias, M A; Gregores, E M; Novaes, S F; Abadjiev, K; Anguelov, T; Damgov, J; Darmenov, N; Dimitrov, L; Genchev, V; Iaydjiev, P; Piperov, S; Stoykova, S; Sultanov, G; Trayanov, R; Vankov, I; Dimitrov, A; Dyulendarova, M; Kozhuharov, V; Litov, L; Marinova, E; Mateev, M; Pavlov, B; Petkov, P; Toteva, Z; Chen, G M; Chen, H S; Guan, W; Jiang, C H; Liang, D; Liu, B; Meng, X; Tao, J; Wang, J; Wang, Z; Xue, Z; Zhang, Z; Ban, Y; Cai, J; Ge, Y; Guo, S; Hu, Z; Mao, Y; Qian, S J; Teng, H; Zhu, B; Avila, C; Baquero Ruiz, M; Carrillo Montoya, C A; Gomez, A; Gomez Moreno, B; Ocampo Rios, A A; Osorio Oliveros, A F; Reyes Romero, D; Sanabria, J C; Godinovic, N; Lelas, K; Plestina, R; Polic, D; Puljak, I; Antunovic, Z; Dzelalija, M; Brigljevic, V; Duric, S; Kadija, K; Morovic, S; Fereos, R; Galanti, M; Mousa, J; Papadakis, A; Ptochos, F; Razis, P A; Tsiakkouri, D; Zinonos, Z; Hektor, A; Kadastik, M; Kannike, K; Müntel, M; Raidal, M; Rebane, L; Anttila, E; Czellar, S; Härkönen, J; Heikkinen, A; Karimäki, V; Kinnunen, R; Klem, J; Kortelainen, M J; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Nysten, J; Tuominen, E; Tuominiemi, J; Ungaro, D; Wendland, L; Banzuzi, K; Korpela, A; Tuuva, T; Nedelec, P; Sillou, D; Besancon, M; Chipaux, R; Dejardin, M; Denegri, D; Descamps, J; Fabbro, B; Faure, J L; Ferri, F; Ganjour, S; Gentit, F X; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Lemaire, M C; Locci, E; Malcles, J; Marionneau, M; Millischer, L; Rander, J; Rosowsky, A; Rousseau, D; Titov, M; Verrecchia, P; Baffioni, S; Bianchini, L; Bluj, M; Busson, P; Charlot, C; Dobrzynski, L; Granier de Cassagnac, R; Haguenauer, M; Miné, P; Paganini, P; Sirois, Y; Thiebaux, C; Zabi, A; Agram, J L; Besson, A; Bloch, D; Bodin, D; Brom, J M; Conte, E; Drouhin, F; Fontaine, J C; Gelé, D; Goerlach, U; Gross, L; Juillot, P; Le Bihan, A C; Patois, Y; Speck, J; Van Hove, P; Baty, C; Bedjidian, M; Blaha, J; Boudoul, G; Brun, H; Chanon, N; Chierici, R; Contardo, D; Depasse, P; Dupasquier, T; El Mamouni, H; Fassi, F; Fay, J; Gascon, S; Ille, B; Kurca, T; Le Grand, T; Lethuillier, M; Lumb, N; Mirabito, L; Perries, S; Vander Donckt, M; Verdier, P; Djaoshvili, N; Roinishvili, N; Roinishvili, V; Amaglobeli, N; Adolphi, R; Anagnostou, G; Brauer, R; Braunschweig, W; Edelhoff, M; Esser, H; Feld, L; Karpinski, W; Khomich, A; Klein, K; Mohr, N; Ostaptchouk, A; Pandoulas, D; Pierschel, G; Raupach, F; Schael, S; Schultz von Dratzig, A; Schwering, G; Sprenger, D; Thomas, M; Weber, M; Wittmer, B; Wlochal, M; Actis, O; Altenhöfer, G; Bender, W; Biallass, P; Erdmann, M; Fetchenhauer, G; Frangenheim, J; Hebbeker, T; Hilgers, G; Hinzmann, A; Hoepfner, K; Hof, C; Kirsch, M; Klimkovich, T; Kreuzer, P; Lanske, D; Merschmeyer, M; Meyer, A; Philipps, B; Pieta, H; Reithler, H; Schmitz, S A; Sonnenschein, L; Sowa, M; Steggemann, J; Szczesny, H; Teyssier, D; Zeidler, C; Bontenackels, M; Davids, M; Duda, M; Flügge, G; Geenen, H; Giffels, M; Haj Ahmad, W; Hermanns, T; Heydhausen, D; Kalinin, S; Kress, T; Linn, A; Nowack, A; Perchalla, L; Poettgens, M; Pooth, O; Sauerland, P; Stahl, A; Tornier, D; Zoeller, M H; Aldaya Martin, M; Behrens, U; Borras, K; Campbell, A; Castro, E; Dammann, D; Eckerlin, G; Flossdorf, A; Flucke, G; Geiser, A; Hatton, D; Hauk, J; Jung, H; Kasemann, M; Katkov, I; Kleinwort, C; Kluge, H; Knutsson, A; Kuznetsova, E; Lange, W; Lohmann, W; Mankel, R; Marienfeld, M; Meyer, A B; Miglioranzi, S; Mnich, J; Ohlerich, M; Olzem, J; Parenti, A; Rosemann, C; Schmidt, R; Schoerner-Sadenius, T; Volyanskyy, D; Wissing, C; Zeuner, W D; Autermann, C; Bechtel, F; Draeger, J; Eckstein, D; Gebbert, U; Kaschube, K; Kaussen, G; Klanner, R; Mura, B; Naumann-Emme, S; Nowak, F; Pein, U; Sander, C; Schleper, P; Schum, T; Stadie, H; Steinbrück, G; Thomsen, J; Wolf, R; Bauer, J; Blüm, P; Buege, V; Cakir, A; Chwalek, T; De Boer, W; Dierlamm, A; Dirkes, G; Feindt, M; Felzmann, U; Frey, M; Furgeri, A; Gruschke, J; Hackstein, C; Hartmann, F; Heier, S; Heinrich, M; Held, H; Hirschbuehl, D; Hoffmann, K H; Honc, S; Jung, C; Kuhr, T; Liamsuwan, T; Martschei, D; Mueller, S; Müller, Th; Neuland, M B; Niegel, M; Oberst, O; Oehler, A; Ott, J; Peiffer, T; Piparo, D; Quast, G; Rabbertz, K; Ratnikov, F; Ratnikova, N; Renz, M; Saout, C; Sartisohn, G; Scheurer, A; Schieferdecker, P; Schilling, F P; Schott, G; Simonis, H J; Stober, F M; Sturm, P; Troendle, D; Trunov, A; Wagner, W; Wagner-Kuhr, J; Zeise, M; Zhukov, V; Ziebarth, E B; Daskalakis, G; Geralis, T; Karafasoulis, K; Kyriakis, A; Loukas, D; Markou, A; Markou, C; Mavrommatis, C; Petrakou, E; Zachariadou, A; Gouskos, L; Katsas, P; Panagiotou, A; Evangelou, I; Kokkas, P; Manthos, N; Papadopoulos, I; Patras, V; Triantis, F A; Bencze, G; Boldizsar, L; Debreczeni, G; Hajdu, C; Hernath, S; Hidas, P; Horvath, D; Krajczar, K; Laszlo, A; Patay, G; Sikler, F; Toth, N; Vesztergombi, G; Beni, N; Christian, G; Imrek, J; Molnar, J; Novak, D; Palinkas, J; Szekely, G; Szillasi, Z; Tokesi, K; Veszpremi, V; Kapusi, A; Marian, G; Raics, P; Szabo, Z; Trocsanyi, Z L; Ujvari, B; Zilizi, G; Bansal, S; Bawa, H S; Beri, S B; Bhatnagar, V; Jindal, M; Kaur, M; Kaur, R; Kohli, J M; Mehta, M Z; Nishu, N; Saini, L K; Sharma, A; Singh, A; Singh, J B; Singh, S P; Ahuja, S; Arora, S; Bhattacharya, S; Chauhan, S; Choudhary, B C; Gupta, P; Jain, S; Jha, M; Kumar, A; Ranjan, K; Shivpuri, R K; Srivastava, A K; Choudhury, R K; Dutta, D; Kailas, S; Kataria, S K; Mohanty, A K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Guchait, M; Gurtu, A; Maity, M; Majumder, D; Majumder, G; Mazumdar, K; Nayak, A; Saha, A; Sudhakar, K; Banerjee, S; Dugad, S; Mondal, N K; Arfaei, H; Bakhshiansohi, H; Fahim, A; Jafari, A; Mohammadi Najafabadi, M; Moshaii, A; Paktinat Mehdiabadi, S; Rouhani, S; Safarzadeh, B; Zeinali, M; Felcini, M; Abbrescia, M; Barbone, L; Chiumarulo, F; Clemente, A; Colaleo, A; Creanza, D; Cuscela, G; De Filippis, N; De Palma, M; De Robertis, G; Donvito, G; Fedele, F; Fiore, L; Franco, M; Iaselli, G; Lacalamita, N; Loddo, F; Lusito, L; Maggi, G; Maggi, M; Manna, N; Marangelli, B; My, S; Natali, S; Nuzzo, S; Papagni, G; Piccolomo, S; Pierro, G A; Pinto, C; Pompili, A; Pugliese, G; Rajan, R; Ranieri, A; Romano, F; Roselli, G; Selvaggi, G; Shinde, Y; Silvestris, L; Tupputi, S; Zito, G; Abbiendi, G; Bacchi, W; Benvenuti, A C; Boldini, M; Bonacorsi, D; Braibant-Giacomelli, S; Cafaro, V D; Caiazza, S S; Capiluppi, P; Castro, A; Cavallo, F R; Codispoti, G; Cuffiani, M; D'Antone, I; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Giordano, V; Giunta, M; Grandi, C; Guerzoni, M; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Odorici, F; Pellegrini, G; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G; Torromeo, G; Travaglini, R; Albergo, S; Costa, S; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Broccolo, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Frosali, S; Gallo, E; Genta, C; Landi, G; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Tropiano, A; Benussi, L; Bertani, M; Bianco, S; Colafranceschi, S; Colonna, D; Fabbri, F; Giardoni, M; Passamonti, L; Piccolo, D; Pierluigi, D; Ponzio, B; Russo, A; Fabbricatore, P; Musenich, R; Benaglia, A; Calloni, M; Cerati, G B; D'Angelo, P; De Guio, F; Farina, F M; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Martelli, A; Menasce, D; Miccio, V; Moroni, L; Negri, P; Paganoni, M; Pedrini, D; Pullia, A; Ragazzi, S; Redaelli, N; Sala, S; Salerno, R; Tabarelli de Fatis, T; Tancini, V; Taroni, S; Buontempo, S; Cavallo, N; Cimmino, A; De Gruttola, M; Fabozzi, F; Iorio, A O M; Lista, L; Lomidze, D; Noli, P; Paolucci, P; Sciacca, C; Azzi, P; Bacchetta, N; Barcellan, L; Bellan, P; Bellato, M; Benettoni, M; Biasotto, M; Bisello, D; Borsato, E; Branca, A; Carlin, R; Castellani, L; Checchia, P; Conti, E; Dal Corso, F; De Mattia, M; Dorigo, T; Dosselli, U; Fanzago, F; Gasparini, F; Gasparini, U; Giubilato, P; Gonella, F; Gresele, A; Gulmini, M; Kaminskiy, A; Lacaprara, S; Lazzizzera, I; Margoni, M; Maron, G; Mattiazzo, S; Mazzucato, M; Meneghelli, M; Meneguzzo, A T; Michelotto, M; Montecassiano, F; Nespolo, M; Passaseo, M; Pegoraro, M; Perrozzi, L; Pozzobon, N; Ronchese, P; Simonetto, F; Toniolo, N; Torassa, E; Tosi, M; Triossi, A; Vanini, S; Ventura, S; Zotto, P; Zumerle, G; Baesso, P; Berzano, U; Bricola, S; Necchi, M M; Pagano, D; Ratti, S P; Riccardi, C; Torre, P; Vicini, A; Vitulo, P; Viviani, C; Aisa, D; Aisa, S; Babucci, E; Biasini, M; Bilei, G M; Caponeri, B; Checcucci, B; Dinu, N; Fanò, L; Farnesini, L; Lariccia, P; Lucaroni, A; Mantovani, G; Nappi, A; Piluso, A; Postolache, V; Santocchia, A; Servoli, L; Tonoiu, D; Vedaee, A; Volpe, R; Azzurri, P; Bagliesi, G; Bernardini, J; Berretta, L; Boccali, T; Bocci, A; Borrello, L; Bosi, F; Calzolari, F; Castaldi, R; Dell'Orso, R; Fiori, F; Foà, L; Gennai, S; Giassi, A; Kraan, A; Ligabue, F; Lomtadze, T; Mariani, F; Martini, L; Massa, M; Messineo, A; Moggi, A; Palla, F; Palmonari, F; Petragnani, G; Petrucciani, G; Raffaelli, F; Sarkar, S; Segneri, G; Serban, A T; Spagnolo, P; Tenchini, R; Tolaini, S; Tonelli, G; Venturi, A; Verdini, P G; Baccaro, S; Barone, L; Bartoloni, A; Cavallari, F; Dafinei, I; Del Re, D; Di Marco, E; Diemoz, M; Franci, D; Longo, E; Organtini, G; Palma, A; Pandolfi, F; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Alampi, G; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Biino, C; Borgia, M A; Botta, C; Cartiglia, N; Castello, R; Cerminara, G; Costa, M; Dattola, D; Dellacasa, G; Demaria, N; Dughera, G; Dumitrache, F; Graziano, A; Mariotti, C; Marone, M; Maselli, S; Migliore, E; Mila, G; Monaco, V; Musich, M; Nervo, M; Obertino, M M; Oggero, S; Panero, R; Pastrone, N; Pelliccioni, M; Romero, A; Ruspa, M; Sacchi, R; Solano, A; Staiano, A; Trapani, P P; Trocino, D; Vilela Pereira, A; Visca, L; Zampieri, A; Ambroglini, F; Belforte, S; Cossutti, F; Della Ricca, G; Gobbo, B; Penzo, A; Chang, S; Chung, J; Kim, D H; Kim, G N; Kong, D J; Park, H; Son, D C; Bahk, S Y; Song, S; Jung, S Y; Hong, B; Kim, H; Kim, J H; Lee, K S; Moon, D H; Park, S K; Rhee, H B; Sim, K S; Kim, J; Choi, M; Hahn, G; Park, I C; Choi, S; Choi, Y; Goh, J; Jeong, H; Kim, T J; Lee, J; Lee, S; Janulis, M; Martisiute, D; Petrov, P; Sabonis, T; Castilla Valdez, H; Sánchez Hernández, A; Carrillo Moreno, S; Morelos Pineda, A; Allfrey, P; Gray, R N C; Krofcheck, D; Bernardino Rodrigues, N; Butler, P H; Signal, T; Williams, J C; Ahmad, M; Ahmed, I; Ahmed, W; Asghar, M I; Awan, M I M; Hoorani, H R; Hussain, I; Khan, W A; Khurshid, T; Muhammad, S; Qazi, S; Shahzad, H; Cwiok, M; Dabrowski, R; Dominik, W; Doroba, K; Konecki, M; Krolikowski, J; Pozniak, K; Romaniuk, Ryszard; Zabolotny, W; Zych, P; Frueboes, T; Gokieli, R; Goscilo, L; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Wrochna, G; Zalewski, P; Almeida, N; Antunes Pedro, L; Bargassa, P; David, A; Faccioli, P; Ferreira Parracho, P G; Freitas Ferreira, M; Gallinaro, M; Guerra Jordao, M; Martins, P; Mini, G; Musella, P; Pela, J; Raposo, L; Ribeiro, P Q; Sampaio, S; Seixas, J; Silva, J; Silva, P; Soares, D; Sousa, M; Varela, J; Wöhri, H K; Altsybeev, I; Belotelov, I; Bunin, P; Ershov, Y; Filozova, I; Finger, M; Finger, M., Jr.; Golunov, A; Golutvin, I; Gorbounov, N; Kalagin, V; Kamenev, A; Karjavin, V; Konoplyanikov, V; Korenkov, V; Kozlov, G; Kurenkov, A; Lanev, A; Makankin, A; Mitsyn, V V; Moisenz, P; Nikonov, E; Oleynik, D; Palichik, V; Perelygin, V; Petrosyan, A; Semenov, R; Shmatov, S; Smirnov, V; Smolin, D; Tikhonenko, E; Vasil'ev, S; Vishnevskiy, A; Volodko, A; Zarubin, A; Zhiltsov, V; Bondar, N; Chtchipounov, L; Denisov, A; Gavrikov, Y; Gavrilov, G; Golovtsov, V; Ivanov, Y; Kim, V; Kozlov, V; Levchenko, P; Obrant, G; Orishchin, E; Petrunin, A; Shcheglov, Y; Shchetkovskiy, A; Sknar, V; Smirnov, I; Sulimov, V; Tarakanov, V; Uvarov, L; Vavilov, S; Velichko, G; Volkov, S; Vorobyev, A; Andreev, Yu; Anisimov, A; Antipov, P; Dermenev, A; Gninenko, S; Golubev, N; Kirsanov, M; Krasnikov, N; Matveev, V; Pashenkov, A; Postoev, V E; Solovey, A; Toropin, A; Troitsky, S; Baud, A; Epshteyn, V; Gavrilov, V; Ilina, N; Kaftanov, V; Kolosov, V; Kossov, M; Krokhotin, A; Kuleshov, S; Oulianov, A; Safronov, G; Semenov, S; Shreyber, I; Stolin, V; Vlasov, E; Zhokin, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Petrushanko, S; Sarycheva, L; Savrin, V; Snigirev, A; Vardanyan, I; Dremin, I; Kirakosyan, M; Konovalova, N; Rusakov, S V; Vinogradov, A; Akimenko, S; Artamonov, A; Azhgirey, I; Bitioukov, S; Burtovoy, V; Grishin, V; Kachanov, V; Konstantinov, D; Krychkine, V; Levine, A; Lobov, I; Lukanin, V; Mel'nik, Y; Petrov, V; Ryutin, R; Slabospitsky, S; Sobol, A; Sytine, A; Tourtchanovitch, L; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Djordjevic, M; Jovanovic, D; Krpic, D; Maletic, D; Puzovic, J; Smiljkovic, N; Aguilar-Benitez, M; Alberdi, J; Alcaraz Maestre, J; Arce, P; Barcala, J M; Battilana, C; Burgos Lazaro, C; Caballero Bejar, J; Calvo, E; Cardenas Montes, M; Cepeda, M; Cerrada, M; Chamizo Llatas, M; Clemente, F; Colino, N; Daniel, M; De La Cruz, B; Delgado Peris, A; Diez Pardos, C; Fernandez Bedoya, C; Fernández Ramos, J P; Ferrando, A; Flix, J; Fouz, M C; Garcia-Abia, P; Garcia-Bonilla, A C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Marin, J; Merino, G; Molina, J; Molinero, A; Navarrete, J J; Oller, J C; Puerta Pelayo, J; Romero, L; Santaolalla, J; Villanueva Munoz, C; Willmott, C; Yuste, C; Albajar, C; Blanco Otano, M; de Trocóniz, J F; Garcia Raboso, A; Lopez Berengueres, J O; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Lloret Iglesias, L; Naves Sordo, H; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chuang, S H; Diaz Merino, I; Diez Gonzalez, C; Duarte Campderros, J; Fernandez, M; Gomez, G; Gonzalez Sanchez, J; Gonzalez Suarez, R; Jorda, C; Lobelle Pardo, P; Lopez Virto, A; Marco, J; Marco, R; Martinez Rivero, C; Martinez Ruiz del Arbol, P; Matorras, F; Rodrigo, T; Ruiz Jimeno, A; Scodellaro, L; Sobron Sanudo, M; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Albert, E; Alidra, M; Ashby, S; Auffray, E; Baechler, J; Baillon, P; Ball, A H; Bally, S L; Barney, D; Beaudette, F; Bellan, R; Benedetti, D; Benelli, G; Bernet, C; Bloch, P; Bolognesi, S; Bona, M; Bos, J; Bourgeois, N; Bourrel, T; Breuker, H; Bunkowski, K; Campi, D; Camporesi, T; Cano, E; Cattai, A; Chatelain, J P; Chauvey, M; Christiansen, T; Coarasa Perez, J A; Conde Garcia, A; Covarelli, R; Curé, B; De Roeck, A; Delachenal, V; Deyrail, D; Di Vincenzo, S; Dos Santos, S; Dupont, T; Edera, L M; Elliott-Peisert, A; Eppard, M; Favre, M; Frank, N; Funk, W; Gaddi, A; Gastal, M; Gateau, M; Gerwig, H; Gigi, D; Gill, K; Giordano, D; Girod, J P; Glege, F; Gomez-Reino Garrido, R; Goudard, R; Gowdy, S; Guida, R; Guiducci, L; Gutleber, J; Hansen, M; Hartl, C; Harvey, J; Hegner, B; Hoffmann, H F; Holzner, A; Honma, A; Huhtinen, M; Innocente, V; Janot, P; Le Godec, G; Lecoq, P; Leonidopoulos, C; Loos, R; Lourenço, C; Lyonnet, A; Macpherson, A; Magini, N; Maillefaud, J D; Maire, G; Mäki, T; Malgeri, L; Mannelli, M; Masetti, L; Meijers, F; Meridiani, P; Mersi, S; Meschi, E; Meynet Cordonnier, A; Moser, R; Mulders, M; Mulon, J; Noy, M; Oh, A; Olesen, G; Onnela, A; Orimoto, T; Orsini, L; Perez, E; Perinic, G; Pernot, J F; Petagna, P; Petiot, P; Petrilli, A; Pfeiffer, A; Pierini, M; Pimiä, M; Pintus, R; Pirollet, B; Postema, H; Racz, A; Ravat, S; Rew, S B; Rodrigues Antunes, J; Rolandi, G; Rovere, M; Ryjov, V; Sakulin, H; Samyn, D; Sauce, H; Schäfer, C; Schlatter, W D; Schröder, M; Schwick, C; Sciaba, A; Segoni, I; Sharma, A; Siegrist, N; Siegrist, P; Sinanis, N; Sobrier, T; Sphicas, P; Spiga, D; Spiropulu, M; Stöckli, F; Traczyk, P; Tropea, P; Troska, J; Tsirou, A; Veillet, L; Veres, G I; Voutilainen, M; Wertelaers, P; Zanetti, M; Bertl, W; Deiters, K; Erdmann, W; Gabathuler, K; Horisberger, R; Ingram, Q; Kaestli, H C; König, S; Kotlinski, D; Langenegger, U; Meier, F; Renker, D; Rohe, T; Sibille, J; Starodumov, A; Betev, B; Caminada, L; Chen, Z; Cittolin, S; Da Silva Di Calafiori, D R; Dambach, S; Dissertori, G; Dittmar, M; Eggel, C; Eugster, J; Faber, G; Freudenreich, K; Grab, C; Hervé, A; Hintz, W; Lecomte, P; Luckey, P D; Lustermann, W; Marchica, C; Milenovic, P; Moortgat, F; Nardulli, A; Nessi-Tedaldi, F; Pape, L; Pauss, F; Punz, T; Rizzi, A; Ronga, F J; Sala, L; Sanchez, A K; Sawley, M C; Sordini, V; Stieger, B; Tauscher, L; Thea, A; Theofilatos, K; Treille, D; Trüb, P; Weber, M; Wehrli, L; Weng, J; Zelepoukine, S; Amsler, C; Chiochia, V; De Visscher, S; Regenfus, C; Robmann, P; Rommerskirchen, T; Schmidt, A; Tsirigkas, D; Wilke, L; Chang, Y H; Chen, E A; Chen, W T; Go, A; Kuo, C M; Li, S W; Lin, W; Bartalini, P; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y; Lei, Y J; Lin, S W; Lu, R S; Schümann, J; Shiu, J G; Tzeng, Y M; Ueno, K; Velikzhanin, Y; Wang, C C; Wang, M; Adiguzel, A; Ayhan, A; Azman Gokce, A; Bakirci, M N; Cerci, S; Dumanoglu, I; Eskut, E; Girgis, S; Gurpinar, E; Hos, I; Karaman, T; Kayis Topaksu, A; Kurt, P; Önengüt, G; Önengüt Gökbulut, G; Ozdemir, K; Ozturk, S; Polatöz, A; Sogut, K; Tali, B; Topakli, H; Uzun, D; Vergili, L N; Vergili, M; Akin, I V; Aliev, T; Bilmis, S; Deniz, M; Gamsizkan, H; Guler, A M; Öcalan, K; Serin, M; Sever, R; Surat, U E; Zeyrek, M; Deliomeroglu, M; Demir, D; Gülmez, E; Halu, A; Isildak, B; Kaya, M; Kaya, O; Ozkorucuklu, S; Sonmez, N; Levchuk, L; Lukyanenko, S; Soroka, D; Zub, S; Bostock, F; Brooke, J J; Cheng, T L; Cussans, D; Frazier, R; Goldstein, J; Grant, N; Hansen, M; Heath, G P; Heath, H F; Hill, C; Huckvale, B; Jackson, J; Mackay, C K; Metson, S; Newbold, D M; Nirunpong, K; Smith, V J; Velthuis, J; Walton, R; Bell, K W; Brew, C; Brown, R M; Camanzi, B; Cockerill, D J A; Coughlan, J A; Geddes, N I; Harder, K; Harper, S; Kennedy, B W; Murray, P; Shepherd-Themistocleous, C H; Tomalin, I R; Williams, J H; Womersley, W J; Worm, S D; Bainbridge, R; Ball, G; Ballin, J; Beuselinck, R; Buchmuller, O; Colling, D; Cripps, N; Davies, G; Della Negra, M; Foudas, C; Fulcher, J; Futyan, D; Hall, G; Hays, J; Iles, G; Karapostoli, G; MacEvoy, B C; Magnan, A M; Marrouche, J; Nash, J; Nikitenko, A; Papageorgiou, A; Pesaresi, M; Petridis, K; Pioppi, M; Raymond, D M; Rompotis, N; Rose, A; Ryan, M J; Seez, C; Sharp, P; Sidiropoulos, G; Stettler, M; Stoye, M; Takahashi, M; Tapper, A; Timlin, C; Tourneur, S; Vazquez Acosta, M; Virdee, T; Wakefield, S; Wardrope, D; Whyntie, T; Wingham, M; Cole, J E; Goitom, I; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Munro, C; Reid, I D; Siamitros, C; Taylor, R; Teodorescu, L; Yaselli, I; Bose, T; Carleton, M; Hazen, E; Heering, A H; Heister, A; John, J St; Lawson, P; Lazic, D; Osborne, D; Rohlf, J; Sulak, L; Wu, S; Andrea, J; Avetisyan, A; Bhattacharya, S; Chou, J P; Cutts, D; Esen, S; Kukartsev, G; Landsberg, G; Narain, M; Nguyen, D; Speer, T; Tsang, K V; Breedon, R; Calderon De La Barca Sanchez, M; Case, M; Cebra, D; Chertok, M; Conway, J; Cox, P T; Dolen, J; Erbacher, R; Friis, E; Ko, W; Kopecky, A; Lander, R; Lister, A; Liu, H; Maruyama, S; Miceli, T; Nikolic, M; Pellett, D; Robles, J; Searle, M; Smith, J; Squires, M; Stilley, J; Tripathi, M; Vasquez Sierra, R; Veelken, C; Andreev, V; Arisaka, K; Cline, D; Cousins, R; Erhan, S; Hauser, J; Ignatenko, M; Jarvis, C; Mumford, J; Plager, C; Rakness, G; Schlein, P; Tucker, J; Valuev, V; Wallny, R; Yang, X; Babb, J; Bose, M; Chandra, A; Clare, R; Ellison, J A; Gary, J W; Hanson, G; Jeng, G Y; Kao, S C; Liu, F; Liu, H; Luthra, A; Nguyen, H; Pasztor, G; Satpathy, A; Shen, B C; Stringer, R; Sturdy, J; Sytnik, V; Wilken, R; Wimpenny, S; Branson, J G; Dusinberre, E; Evans, D; Golf, F; Kelley, R; Lebourgeois, M; Letts, J; Lipeles, E; Mangano, B; Muelmenstaedt, J; Norman, M; Padhi, S; Petrucci, A; Pi, H; Pieri, M; Ranieri, R; Sani, M; Sharma, V; Simon, S; Würthwein, F; Yagil, A; Campagnari, C; D'Alfonso, M; Danielson, T; Garberson, J; Incandela, J; Justus, C; Kalavase, P; Koay, S A; Kovalskyi, D; Krutelyov, V; Lamb, J; Lowette, S; Pavlunin, V; Rebassoo, F; Ribnik, J; Richman, J; Rossin, R; Stuart, D; To, W; Vlimant, J R; Witherell, M; Apresyan, A; Bornheim, A; Bunn, J; Chiorboli, M; Gataullin, M; Kcira, D; Litvine, V; Ma, Y; Newman, H B; Rogan, C; Timciuc, V; Veverka, J; Wilkinson, R; Yang, Y; Zhang, L; Zhu, K; Zhu, R Y; Akgun, B; Carroll, R; Ferguson, T; Jang, D W; Jun, S Y; Paulini, M; Russ, J; Terentyev, N; Vogel, H; Vorobiev, I; Cumalat, J P; Dinardo, M E; Drell, B R; Ford, W T; Heyburn, B; Luiggi Lopez, E; Nauenberg, U; Stenson, K; Ulmer, K; Wagner, S R; Zang, S L; Agostino, L; Alexander, J; Blekman, F; Cassel, D; Chatterjee, A; Das, S; Gibbons, L K; Heltsley, B; Hopkins, W; Khukhunaishvili, A; Kreis, B; Kuznetsov, V; Patterson, J R; Puigh, D; Ryd, A; Shi, X; Stroiney, S; Sun, W; Teo, W D; Thom, J; Vaughan, J; Weng, Y; Wittich, P; Beetz, C P; Cirino, G; Sanzeni, C; Winn, D; Abdullin, S; Afaq, M A; Albrow, M; Ananthan, B; Apollinari, G; Atac, M; Badgett, W; Bagby, L; Bakken, J A; Baldin, B; Banerjee, S; Banicz, K; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Biery, K; Binkley, M; Bloch, I; Borcherding, F; Brett, A M; Burkett, K; Butler, J N; Chetluru, V; Cheung, H W K; Chlebana, F; Churin, I; Cihangir, S; Crawford, M; Dagenhart, W; Demarteau, M; Derylo, G; Dykstra, D; Eartly, D P; Elias, J E; Elvira, V D; Evans, D; Feng, L; Fischler, M; Fisk, I; Foulkes, S; Freeman, J; Gartung, P; Gottschalk, E; Grassi, T; Green, D; Guo, Y; Gutsche, O; Hahn, A; Hanlon, J; Harris, R M; Holzman, B; Howell, J; Hufnagel, D; James, E; Jensen, H; Johnson, M; Jones, C D; Joshi, U; Juska, E; Kaiser, J; Klima, B; Kossiakov, S; Kousouris, K; Kwan, S; Lei, C M; Limon, P; Lopez Perez, J A; Los, S; Lueking, L; Lukhanin, G; Lusin, S; Lykken, J; Maeshima, K; Marraffino, J M; Mason, D; McBride, P; Miao, T; Mishra, K; Moccia, S; Mommsen, R; Mrenna, S; Muhammad, A S; Newman-Holmes, C; Noeding, C; O'Dell, V; Prokofyev, O; Rivera, R; Rivetta, C H; Ronzhin, A; Rossman, P; Ryu, S; Sekhri, V; Sexton-Kennedy, E; Sfiligoi, I; Sharma, S; Shaw, T M; Shpakov, D; Skup, E; Smith, R P; Soha, A; Spalding, W J; Spiegel, L; Suzuki, I; Tan, P; Tanenbaum, W; Tkaczyk, S; Trentadue, R; Uplegger, L; Vaandering, E W; Vidal, R; Whitmore, J; Wicklund, E; Wu, W; Yarba, J; Yumiceva, F; Yun, J C; Acosta, D; Avery, P; Barashko, V; Bourilkov, D; Chen, M; Di Giovanni, G P; Dobur, D; Drozdetskiy, A; Field, R D; Fu, Y; Furic, I K; Gartner, J; Holmes, D; Kim, B; Klimenko, S; Konigsberg, J; Korytov, A; Kotov, K; Kropivnitskaya, A; Kypreos, T; Madorsky, A; Matchev, K; Mitselmakher, G; Pakhotin, Y; Piedra Gomez, J; Prescott, C; Rapsevicius, V; Remington, R; Schmitt, M; Scurlock, B; Wang, D; Yelton, J; Ceron, C; Gaultney, V; Kramer, L; Lebolo, L M; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Adams, T; Askew, A; Baer, H; Bertoldi, M; Chen, J; Dharmaratna, W G D; Gleyzer, S V; Haas, J; Hagopian, S; Hagopian, V; Jenkins, M; Johnson, K F; Prettner, E; Prosper, H; Sekmen, S; Baarmand, M M; Guragain, S; Hohlmann, M; Kalakhety, H; Mermerkaya, H; Ralich, R; Vodopiyanov, I; Abelev, B; Adams, M R; Anghel, I M; Apanasevich, L; Bazterra, V E; Betts, R R; Callner, J; Castro, M A; Cavanaugh, R; Dragoiu, C; Garcia-Solis, E J; Gerber, C E; Hofman, D J; Khalatian, S; Mironov, C; Shabalina, E; Smoron, A; Varelas, N; Akgun, U; Albayrak, E A; Ayan, A S; Bilki, B; Briggs, R; Cankocak, K; Chung, K; Clarida, W; Debbins, P; Duru, F; Ingram, F D; Lae, C K; McCliment, E; Merlo, J P; Mestvirishvili, A; Miller, M J; Moeller, A; Nachtman, J; Newsom, C R; Norbeck, E; Olson, J; Onel, Y; Ozok, F; Parsons, J; Schmidt, I; Sen, S; Wetzel, J; Yetkin, T; Yi, K; Barnett, B A; Blumenfeld, B; Bonato, A; Chien, C Y; Fehling, D; Giurgiu, G; Gritsan, A V; Guo, Z J; Maksimovic, P; Rappoccio, S; Swartz, M; Tran, N V; Zhang, Y; Baringer, P; Bean, A; Grachov, O; Murray, M; Radicci, V; Sanders, S; Wood, J S; Zhukova, V; Bandurin, D; Bolton, T; Kaadze, K; Liu, A; Maravin, Y; Onoprienko, D; Svintradze, I; Wan, Z; Gronberg, J; Hollar, J; Lange, D; Wright, D; Baden, D; Bard, R; Boutemeur, M; Eno, S C; Ferencek, D; Hadley, N J; Kellogg, R G; Kirn, M; Kunori, S; Rossato, K; Rumerio, P; Santanastasio, F; Skuja, A; Temple, J; Tonjes, M B; Tonwar, S C; Toole, T; Twedt, E; Alver, B; Bauer, G; Bendavid, J; Busza, W; Butz, E; Cali, I A; Chan, M; D'Enterria, D; Everaerts, P; Gomez Ceballos, G; Hahn, K A; Harris, P; Jaditz, S; Kim, Y; Klute, M; Lee, Y J; Li, W; Loizides, C; Ma, T; Miller, M; Nahn, S; Paus, C; Roland, C; Roland, G; Rudolph, M; Stephans, G; Sumorok, K; Sung, K; Vaurynovich, S; Wenger, E A; Wyslouch, B; Xie, S; Yilmaz, Y; Yoon, A S; Bailleux, D; Cooper, S I; Cushman, P; Dahmes, B; De Benedetti, A; Dolgopolov, A; Dudero, P R; Egeland, R; Franzoni, G; Haupt, J; Inyakin, A; Klapoetke, K; Kubota, Y; Mans, J; Mirman, N; Petyt, D; Rekovic, V; Rusack, R; Schroeder, M; Singovsky, A; Zhang, J; Cremaldi, L M; Godang, R; Kroeger, R; Perera, L; Rahmat, R; Sanders, D A; Sonnek, P; Summers, D; Bloom, K; Bockelman, B; Bose, S; Butt, J; Claes, D R; Dominguez, A; Eads, M; Keller, J; Kelly, T; Kravchenko, I; Lazo-Flores, J; Lundstedt, C; Malbouisson, H; Malik, S; Snow, G R; Baur, U; Iashvili, I; Kharchilava, A; Kumar, A; Smith, K; Strang, M; Alverson, G; Barberis, E; Boeriu, O; Eulisse, G; Govi, G; McCauley, T; Musienko, Y; Muzaffar, S; Osborne, I; Paul, T; Reucroft, S; Swain, J; Taylor, L; Tuura, L; Anastassov, A; Gobbi, B; Kubik, A; Ofierzynski, R A; Pozdnyakov, A; Schmitt, M; Stoynev, S; Velasco, M; Won, S; Antonelli, L; Berry, D; Hildreth, M; Jessop, C; Karmgard, D J; Kolberg, T; Lannon, K; Lynch, S; Marinelli, N; Morse, D M; Ruchti, R; Slaunwhite, J; Warchol, J; Wayne, M; Bylsma, B; Durkin, L S; Gilmore, J; Gu, J; Killewald, P; Ling, T Y; Williams, G; Adam, N; Berry, E; Elmer, P; Garmash, A; Gerbaudo, D; Halyo, V; Hunt, A; Jones, J; Laird, E; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Piroué, P; Stickland, D; Tully, C; Werner, J S; Wildish, T; Xie, Z; Zuranski, A; Acosta, J G; Bonnett Del Alamo, M; Huang, X T; Lopez, A; Mendez, H; Oliveros, S; Ramirez Vargas, J E; Santacruz, N; Zatzerklyany, A; Alagoz, E; Antillon, E; Barnes, V E; Bolla, G; Bortoletto, D; Everett, A; Garfinkel, A F; Gecse, Z; Gutay, L; Ippolito, N; Jones, M; Koybasi, O; Laasanen, A T; Leonardo, N; Liu, C; Maroussov, V; Merkel, P; Miller, D H; Neumeister, N; Sedov, A; Shipsey, I; Yoo, H D; Zheng, Y; Jindal, P; Parashar, N; Cuplov, V; Ecklund, K M; Geurts, F J M; Liu, J H; Maronde, D; Matveev, M; Padley, B P; Redjimi, R; Roberts, J; Sabbatini, L; Tumanov, A; Betchart, B; Bodek, A; Budd, H; Chung, Y S; de Barbaro, P; Demina, R; Flacher, H; Gotra, Y; Harel, A; Korjenevski, S; Miner, D C; Orbaker, D; Petrillo, G; Vishnevskiy, D; Zielinski, M; Bhatti, A; Demortier, L; Goulianos, K; Hatakeyama, K; Lungu, G; Mesropian, C; Yan, M; Atramentov, O; Bartz, E; Gershtein, Y; Halkiadakis, E; Hits, D; Lath, A; Rose, K; Schnetzer, S; Somalwar, S; Stone, R; Thomas, S; Watts, T L; Cerizza, G; Hollingsworth, M; Spanier, S; Yang, Z C; York, A; Asaadi, J; Aurisano, A; Eusebi, R; Golyash, A; Gurrola, A; Kamon, T; Nguyen, C N; Pivarski, J; Safonov, A; Sengupta, S; Toback, D; Weinberger, M; Akchurin, N; Berntzon, L; Gumus, K; Jeong, C; Kim, H; Lee, S W; Popescu, S; Roh, Y; Sill, A; Volobouev, I; Washington, E; Wigmans, R; Yazgan, E; Engh, D; Florez, C; Johns, W; Pathak, S; Sheldon, P; Andelin, D; Arenton, M W; Balazs, M; Boutle, S; Buehler, M; Conetti, S; Cox, B; Hirosky, R; Ledovskoy, A; Neu, C; Phillips II, D; Ronquest, M; Yohay, R; Gollapinni, S; Gunthoti, K; Harr, R; Karchin, P E; Mattson, M; Sakharov, A; Anderson, M; Bachtis, M; Bellinger, J N; Carlsmith, D; Crotty, I; Dasu, S; Dutta, S; Efron, J; Feyzi, F; Flood, K; Gray, L; Grogg, K S; Grothe, M; Hall-Wilton, R; Jaworski, M; Klabbers, P; Klukas, J; Lanaro, A; Lazaridis, C; Leonard, J; Loveless, R; Magrans de Abril, M; Mohapatra, A; Ott, G; Polese, G; Reeder, D; Savin, A; Smith, W H; Sourkov, A; Swanson, J; Weinberg, M; Wenman, D; Wensveen, M; White, A

    2010-01-01

    This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Timing performance results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. The inter-channel synchronization is measured to be within 2 ns.

  18. High-energy lattice for first-beam operation of the SRF test accelerator at NML

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, C.; /NICADD, DeKalb; Piot, P.; /NICADD, DeKalb /Fermilab; Church, M.; /Fermilab

    2011-09-01

    The Superconducting Radio Frequency Test Accelerator, a linear electron accelerator currently in construction at Fermilab's New Muon Laboratory, will eventually reach energies of {approx} 900 MeV using four ILC-type superconducting accelerating cryomodules. The accelerator's construction is staged according to cryomodules availability. The first phase that will support first beam operation incorporates one cryomodule. In this Note, we summarize a possible design for the first-beam accelerator configuration.

  19. Feasibility tests of a new all-digital beam control scheme for LEIR

    CERN Document Server

    Angoletta, Maria Elena; Findlay, A; Pedersen, F; CERN. Geneva. AB Department

    2004-01-01

    The new Low Energy Ion Ring (LEIR), to be commissioned at CERN in early 2005, will be a very important element of the LHC lead ions injection chain and will require a new beam control and cavity servoing system. Current plans call for a new all-digital beam control system based on the same technology deployed at Brookhaven National Laboratory (BNL) for the to control the AGS Booster beam. That beam control system, now under development, relies on VME modules and daughter boards based on Digital Signal Processors (DSPs) and Field Programmable Gate Arrays (FPGAs). The DSP provides high throughput processing capabilities and ease of connection with the software layer immediately above, while the daughter boards implement master clock, digital receiver and modulator capabilities. The resulting system is very flexible because is configurable via software and offers multi-processing capabilities and high bandwidth data paths, features that make it very attractive for a beam control implementation. For application t...

  20. Results from Tests of a Preshower Prototype During 1996

    CERN Document Server

    Aspell, Paul; Bloch, Philippe; Bourotte, Jean; Reynaud, Serge; Van Hove, Alain

    1997-01-01

    During 1996 a first version of the front-end electronics for the CMS preshower was tested in the laboratory. The 40MHz electronics contained a 32 channel, 128 time-slot analogue memory. Satisfactory results obtained from laboratory tests led to its use in tests using high energy beams incident on a silicon detector placed downstream of a thickness of lead absorber, representative of the CMS preshower. Adequate noise performance was achieved ( leading to the measurement of single mip signals) after individual pedestals for each time-slot were subtracted; this will not be necessary in the future. The spatial precision obtained from the prototype is in good agreement with simulation. The contribution to the ECAL energy resolution is found to be negligible for incident electron energies greater than about 100 GeV ( corresponding to about 40 GeV Et at eta=1.7) after a "correction function" has been applied to the energy measured in the lead tungstate ( PbWO4) crystals. This correction function uses the signals mea...

  1. Design, Fabrication, and Testing of Composite Energy-Absorbing Keel Beams for General Aviation Type Aircraft

    Science.gov (United States)

    Kellas, Sotiris; Knight, Norman F., Jr.

    2002-01-01

    A lightweight energy-absorbing keel-beam concept was developed and retrofitted in a general aviation type aircraft to improve crashworthiness performance. The energy-absorbing beam consisted of a foam-filled cellular structure with glass fiber and hybrid glass/kevlar cell walls. Design, analysis, fabrication and testing of the keel beams prior to installation and subsequent full-scale crash testing of the aircraft are described. Factors such as material and fabrication constraints, damage tolerance, crush stress/strain response, seat-rail loading, and post crush integrity, which influenced the course of the design process are also presented. A theory similar to the one often used for ductile metal box structures was employed with appropriate modifications to estimate the sustained crush loads for the beams. This, analytical tool, coupled with dynamic finite element simulation using MSC.Dytran were the prime design and analysis tools. The validity of the theory as a reliable design tool was examined against test data from static crush tests of beam sections while the overall performance of the energy-absorbing subfloor was assessed through dynamic testing of 24 in long subfloor assemblies.

  2. SU-E-T-354: Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J; Farrokhkish, M; Norrlinger, B; Wang, Y [Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Heaton, R; Jaffray, D; Islam, M [Princess Margaret Cancer Centre, Toronto, Ontario (Canada); University of Toronto, Toronto, Ontario (Canada)

    2015-06-15

    Purpose: To investigate the feasibility of performing routine QA tests of linear accelerators (Linac) using the Integral Quality Monitoring (IQM) system. The system, consisting of a 1-D sensitivity gradient large area ion-chamber mounted at the collimator, allows automatic collection and analysis of beam data. Methods: The IQM was investigated to perform several QA constancy tests, similar to those recommended by AAPM TG142, of a Linac including: beam output, MLC calibration, beam symmetry, relative dose factor (RDF), dose linearity, output as a function of gantry angle and dose rate. All measurements by the IQM system accompanied a reference measurement using a conventional dosimetry system and were performed on an Elekta Infinity Linac with Agility MLC. The MLC calibration check is done using a Picket-Fence type 2×10cm{sup 2} field positioned at different off-axis locations along the chamber gradient. Beam symmetry constancy values are established by signals from an 4×4cm{sup 2} aperture located at various off-axis positions; the sensitivity of the test was determined by the changes in the signals in response to a tilt in the beam. The data for various square field sizes were used to develop a functional relationship with RDF. Results: The IQM tracked the beam output well within 1% of the reference ion-chamber readings. The Picket-Fence type field test detected a 1mm shift error of one MLC bank. The system was able to detect 2.5% or greater beam asymmetry. The IQM results for all other QA tests were found to agree with the reference values to within 0.5%. Conclusion: It was demonstrated that the IQM system can effectively monitor the Linac performance parameters for the purpose of routine QA constancy tests. With minimum user interactions a comprehensive set of tests can be performed efficiently, allowing frequent monitoring of the Linac. The presenting author’s salary is funded by the manufacturer of the QA device. All the other authors have financial

  3. Beam acceleration test in negative-ion based NBI system for JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, K.; Akino, N.; Araki, M.; Ebisawa, N.; Fujiwara, Y.; Hanada, M.; Honda, A.; Inoue, T.; Itoh, T.; Kawai, M.; Kazawa, M.; Koizumi, J.; Kuriyama, M.; Miyamoto, K.; Miyamoto, N.; Mogaki, K.; Nagase, A.; Ohara, Y.; Ohga, T.; Okumura, Y.; Oohara, H.; Ohshima, K.; Satoh, F.; Takahashi, S.; Takenouchi, T.; Usami, H.; Usui, K.; Yamamoto, M.; Yamazaki, T. [Japan Atomic Energy Research Institute, Naka-machi, Naka-gun, Ibaraki-ken, 311-01 (Japan)

    1996-07-01

    Beam extraction and acceleration test in the Negative Ion Based Neutral Beam Injector for JT-60U has been started using one ion source that is designed to produce a 500 keV, 22 A D{sup {minus}} ion beam. Deuterium negative ions are produced in a cesium-seeded semi-cylindrical plasma generator and accelerated by a multi-aperture three-stage electrostatic accelerator. In the preliminary experiment of beam acceleration, the D{sup {minus}} ion beam of 13.5 A was successfully accelerated to 400 keV for a pulse duration of 0.12 s. The negative ion beam power was 5.4 MW. The operating gas pressure in the plasma generator was as low as 0.22 Pa. The highest energy beam of 460 keV, 2.4 A, 0.44 s was also obtained. The ratio of extracted electron current to extracted negative ion current is estimated Ie/I{sub D{sup {minus}}}{lt}1. It was confirmed that the electron leak from the extractor to the accelerator is suppressed efficiently by the effects of biassing, electron trapping gap and magnetic field. {copyright} {ital 1996 American Institute of Physics.}

  4. ELECTRON AND OPTICAL BEAM TESTING OF INTEGRATED CIRCUITS

    OpenAIRE

    Collin, J.-P.

    1989-01-01

    The evolution of Integrated Circuits technology and architecture is pushing today the associated test and characterization technology to even higher levels. The test must not only present even higher parametric performances like voltage, temporal and spatial resolutions and a good fault coverage but also high level functionalities like a CAD link and automation capabilities. Each and all of these characteristics, when they are identified as measurement and functional performances, need more a...

  5. Chracterization of the beam from the RFQ of the PIP-II Injector Test

    Energy Technology Data Exchange (ETDEWEB)

    Shemyakin, A. [Fermilab; Carneiro. J.-P., Carneiro. J.-P. [Fermilab; Hanna, B. [Fermilab; Prost, L. [Fermilab; Saini, A. [Fermilab; Scarpine, V. [Fermilab; Sista, V. L.S. [Bhabha Atomic Res. Ctr.; Steimel, J. [Fermilab

    2017-05-01

    A 2.1 MeV, 10 mA CW RFQ has been installed and commissioned at the Fermilab’s test accelerator known as PIP-II Injector Test. This report describes the measure-ments of the beam properties after acceleration in the RFQ, including the energy and emittance.

  6. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    CERN Document Server

    Adli, E; Dubrovskiy, A; Syratchev, I; Ruber, R; Ziemann, V

    2011-01-01

    We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter reg...

  7. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    Directory of Open Access Journals (Sweden)

    E. Adli

    2011-08-01

    Full Text Available We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter regime of CLIC.

  8. Successful beam test of the SPS-to-LHC transfer line TI2

    CERN Multimedia

    2007-01-01

    Image of the first beam spot on the last BTV screen traversed by the beam during the TI 2 test.At 12:03:47 on 28 October a beam passed down the 2.7 km of the new SPS-to-LHC transfer line TI 2 at the first attempt, to within some 50 m of the LHC tunnel. After initial tuning, a range of measurements was carried out with a low intensity proton beam and preliminary analyses look good. After the test, no increase in radiation levels was found in either the LHC or ALICE, and the zones were rapidly opened again for access. As from next year TI 2 will regularly transport a beam from the SPS to the LHC injection point of Ring 1, near Point 2 (ALICE). The TI 8 transfer line, which will bring particles from the SPS to the injection point in Ring 2, near Point 8 (LHCb), was commissioned successfully with low intensity beam in 2004. The two LHC injection lines have a combined length of 5.6 km and comprise some seven hundred warm magnets. While a...

  9. Preliminary Beam Tests at REX for an Automatic Cavity Phasing Routine at HIE-ISOLDE

    CERN Document Server

    Fraser, M A; Broere, J; Lanaia, D; Valuch, D

    2013-01-01

    The HIE upgrade at ISOLDE will use 32 independently phased superconducting quarterwave cavities, which will impose new demands on the operation and set-up of the linac. The large range of different radioactive species and the broad experimental programme means that the same beam species and energy are rarely studied twice, and the accelerator must be re-tuned for each experimental run. In order to expedite machine set-up it is foreseen to calculate and set automatically the cavity phases when the operator inputs the desired beam energy and A/q of the beam species. In this note we explore our understanding of the REX rf system and test our beam dynamics calculations with two independently phased 7-gap split-ring cavities.

  10. Review of the Drive Beam Stabilization in the CLIC Test Facility CTF3

    CERN Document Server

    Dubrovskiy, A; Skowronski, P; Tecker, F; Persson, T

    2013-01-01

    CTF3 is a Test Facility focusing on beam-based studies of the key concepts of the Compact Linear Collider CLIC. Over the past several years many aspects of the CLIC two-beam acceleration scheme were studied in CTF3, including the crucial issue of drive beam stability. The main sources of drifts and instabilities have been identified and mitigated, helping to improve the machine performance and showing significant progress towards the experimental demonstration of the very stringent requirements on current, energy and phase stability needed in CLIC. In this paper, the more effective techniques and feed-backs are summarized. The latest measurements on beam stability are reported and their relevance to CLIC is discussed.

  11. Testing CPT conservation using the NuMI neutrino beam with the MINOS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Auty, David John [Univ. of Sussex, Brighton (United Kingdom)

    2010-03-01

    The MINOS experiment was designed to measure neutrino oscillation parameters with muon neutrinos. It achieves this by measuring the neutrino energy spectrum and flavor composition of the man-made NuMI neutrino beam 1km after the beam is formed and again after 735 km. By comparing the two spectra it is possible to measure the oscillation parameters. The NuMI beam is made up of 7.0%$\\bar{v}$μ, which can be separated from the vμ because the MINOS detectors are magnetized. This makes it possible to study $\\bar{v}$μ oscillations separately from those of muon neutrinos, and thereby test CPT invariance in the neutrino sector by determining the $\\bar{v}$μ oscillation parameters and comparing them with those for vμ, although any unknown physics of the antineutrino would appear as a difference in oscillation parameters. Such a test has not been performed with beam $\\bar{v}$μ before. It is also possible to produce an almost pure $\\bar{v}$μ beam by reversing the current through the magnetic focusing horns of the NuMI beamline, thereby focusing negatively, instead of positively charged particles. This thesis describes the analysis of the 7% $\\bar{v}$μ component of the forward horn current NuMI beam. The $\\bar{v}$μ of a data sample of 3.2 x 10{sup 20} protons on target analysis found 42 events, compared to a CPT conserving prediction of 58.3-7.6+7.6(stat.)-3.6+3.6(syst.) events. This corresponds to a 1.9 σ deficit, and a best fit value of Δ$\\bar{m}$322 = 18 x 10-3 eV2 and sin2 2$\\bar{θ}$23 = 0.55. This thesis focuses particularly on the selection of $\\bar{v}$μ events, and investigates possible improvements of the selection algorithm. From this a different selector was chosen, which corroborated the findings of the original selector. The

  12. Commissioning experience and beam physics measurements at the SwissFEL Injector test Facility

    CERN Document Server

    Schietinger, T.; Aiba, M.; Arsov, V.; Bettoni, S.; Beutner, B.; Calvi, M.; Craievich, P.; Dehler, M.; Frei, F.; Ganter, R.; Hauri, C. P.; Ischebeck, R.; Ivanisenko, Y.; Janousch, M.; Kaiser, M.; Keil, B.; Löhl, F.; Orlandi, G. L.; Ozkan Loch, C.; Peier, P.; Prat, E.; Raguin, J.-Y.; Reiche, S.; Schilcher, T.; Wiegand, P.; Zimoch, E.; Anicic, D.; Armstrong, D.; Baldinger, M.; Baldinger, R.; Bertrand, A.; Bitterli, K.; Bopp, M.; Brands, H.; Braun, H. H.; Brönnimann, M.; Brunnenkant, I.; Chevtsov, P.; Chrin, J.; Citterio, A.; Csatari Divall, M.; Dach, M.; Dax, A.; Ditter, R.; Divall, E.; Falone, A.; Fitze, H.; Geiselhart, C.; Guetg, M. W.; Hämmerli, F.; Hauff, A.; Heiniger, M.; Higgs, C.; Hugentobler, W.; Hunziker, S.; Janser, G.; Kalantari, B.; Kalt, R.; Kim, Y.; Koprek, W.; Korhonen, T.; Krempaska, R.; Laznovsky, M.; Lehner, S.; Le Pimpec, F.; Lippuner, T.; Lutz, H.; Mair, S.; Marcellini, F.; Marinkovic, G.; Menzel, R.; Milas, N.; Pal, T.; Pollet, P.; Portmann, W.; Rezaeizadeh, A.; Ritt, S.; Rohrer, M.; Schär, M.; Schebacher, L.; Scherrer, St.; Schlott, V.; Schmidt, T.; Schulz, L.; Smit, B.; Stadler, M.; Steffen, Bernd; Stingelin, L.; Sturzenegger, W.; Treyer, D. M.; Trisorio, A.; Tron, W.; Vicario, C.; Zennaro, R.; Zimoch, D.

    2016-10-26

    The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and test bed for the development and realization of SwissFEL, the x-ray Free Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including atransverse deflecting rf cavity. It delivered electron bunchesof up to200 pC chargeand up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of a FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultralow-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measureme...

  13. Collimation quench test with 6.5 TeV proton beams

    CERN Document Server

    Salvachua Ferrando, Belen Maria; Bruce, Roderik; Hermes, Pascal Dominik; Holzer, Eva Barbara; Jacquet, Delphine; Kalliokoski, Matti; Mereghetti, Alessio; Mirarchi, Daniele; Redaelli, Stefano; Skordis, Eleftherios; Valentino, Gianluca; Valloni, Alessandra; Wollmann, Daniel; Zerlauth, Markus; CERN. Geneva. ATS Department

    2016-01-01

    We show here the analysis of the MD test that aimed to quench the superconducting magnets in the dispersion suppressor region downstream of the main betatron collimation system. In Run I there were several attempts to quench the magnets in the same region. This was done by exciting the Beam 2 in a controlled way using the transverse damper and generating losses leaking from the collimation cleaning. No quench was achieved in 2013 with a maximum of 1 MW of beam power loss absorbed by the collimation system at 4 TeV beam energy. In 2015 a new collimation quench test was done at 6.5 TeV aiming at similar power loss over longer period, 5-10 s. The main outcome of this test is reviewed.

  14. Study of the 2004 End-Cap beam tests of the ATLAS detector

    CERN Document Server

    Bieri, Marco

    The ATLAS detector is an all-purpose detector to study high-ener gy proton–proton colli- sions. ATLAS is located at the LHC (Lar ge Hadron Collider) at CERN in Gene va, Switzer - land. Before first data taking, man y beam tests have been carried out in order to fully understand each detector component. The studies in this thesis will concentrate on the 2004 beam test of the entire combined end-cap calorimeter system. The first section of this thesis outlines particle selection in the incoming test beam, eliminating contamination in order to have an accurate calibration environment. The remainder of the thesis focuses on detector calibration and performance studies, including signal-to-ener gy calibration con- stant determination, and various detector ener gy summation methods studying their effect on response. Ov erall detector ener gy sharing characteristics including the response of dead detector regions is also presented.

  15. Mechanical Design of a High Energy Beam Absorber for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Baffes, C.; Church, M.; Leibfritz, J.; Oplt, S.; Rakhno, I.; /Fermilab

    2012-05-10

    A high energy beam absorber has been built for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab. In the facility's initial configuration, an electron beam will be accelerated through 3 TTF-type or ILC-type SRF cryomodules to an energy of 750MeV. The electron beam will be directed to one of multiple downstream experimental and diagnostic beam lines and then deposited in one of two beam absorbers. The facility is designed to accommodate up to 6 cryomodules, which would produce a 75kW beam at 1.5GeV; this is the driving design condition for the beam absorbers. The beam absorbers consist of water-cooled graphite, aluminum and copper layers contained in a helium-filled enclosure. This paper describes the mechanical implementation of the beam absorbers, with a focus on thermal design and analysis. The potential for radiation-induced degradation of the graphite is discussed.

  16. Multi-shaped beam: development status and update on lithography results

    Science.gov (United States)

    Slodowski, Matthias; Doering, Hans-Joachim; Dorl, Wolfgang; Stolberg, Ines A.

    2011-04-01

    According to the ITRS [1] photo mask is a significant challenge for the 22nm technology node requirements and beyond. Mask making capability and cost escalation continue to be critical for future lithography progress. On the technological side mask specifications and complexity have increased more quickly than the half-pitch requirements on the wafer designated by the roadmap due to advanced optical proximity correction and double patterning demands. From the economical perspective mask costs have significantly increased each generation, in which mask writing represents a major portion. The availability of a multi-electron-beam lithography system for mask write application is considered a potential solution to overcome these challenges [2, 3]. In this paper an update of the development status of a full-package high-throughput multi electron-beam writer, called Multi Shaped Beam (MSB), will be presented. Lithography performance results, which are most relevant for mask writing applications, will be disclosed. The MSB technology is an evolutionary development of the matured single Variable Shaped Beam (VSB) technology. An arrangement of Multi Deflection Arrays (MDA) allows operation with multiple shaped beams of variable size, which can be deflected and controlled individually [4]. This evolutionary MSB approach is associated with a lower level of risk and a relatively short time to implementation compared to the known revolutionary concepts [3, 5, 6]. Lithography performance is demonstrated through exposed pattern. Further details of the substrate positioning platform performance will be disclosed. It will become apparent that the MSB operational mode enables lithography on the same and higher performance level compared to single VSB and that there are no specific additional lithography challenges existing beside those which have already been addressed [1].

  17. Accelerator beam test of the kinematic lightweight energy meter detector prototype for very high energy cosmic ray measurements in space

    CERN Document Server

    Bashindzhagian, G L

    2004-01-01

    The idea of the KLEM (Kinematic Lightweight Energy Meter) detector is to directly measure the elemental energy spectra of very high-energy cosmic rays in space by determining the angular distribution of secondary particles produced in a target. The first test of the simple KLEM prototype was performed at the CERN SPS test-beam with 180 GeV pions. The results of the first test analysis confirm that, using the KLEM method, the energy of 180 GeV pions can be measured with a relative error of about 67%, which is very close to the results of the simulation (65 %).

  18. Adaptive support for aircraft panel testing: New method and its experimental verification on a beam structure

    Science.gov (United States)

    Sachau, Delf; Baschke, Manuel

    2017-04-01

    Acoustic transmissibility of aircraft panels is measured in full-scale test rigs. The panels are supported at their frames. These boundary conditions do not take into account the dynamic influence of the fuselage, which is significant in the frequency range below 300 Hz. This paper introduces a new adaptive boundary system (ABS). It combines accelerometers and electrodynamic shakers with real-time signal processing. The ABS considers the dynamic effect of the fuselage on the panel. The frames are dominating the dynamic behaviour of a fuselage in the low-frequency range. Therefore, the new method is applied to a beam representing a frame of the aircraft structure. The experimental results are evaluated and the precision of the ABS is discussed. The theoretical apparent mass representing the cut-off part of a frame is calculated and compared with the apparent mass, as provided by the ABS. It is explained how the experimental set-up limits the precision of the ABS.

  19. Design studies and sensor tests for the beam calorimeter of the ILC detector

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsova, E.

    2007-03-15

    The International Linear Collider (ILC) is being designed to explore particle physics at the TeV scale. The design of the Very Forward Region of the ILC detector is considered in the presented work. The Beam Calorimeter - one of two electromagnetic calorimeters situated there - is the subject of this thesis. The Beam Calorimeter has to provide a good hermeticity for high energy electrons, positrons and photons down to very low polar angles, serve for fast beam diagnostics and shield the inner part of the detector from backscattered beamstrahlung remnants and synchrotron radiation. As a possible technology for the Beam Calorimeter a diamond-tungsten sandwich calorimeter is considered. Detailed simulation studies are done in order to explore the suitability of the considered design for the Beam Calorimeter objectives. Detection efficiency, energy and angular resolution for electromagnetic showers are studied. At the simulation level the diamondtungsten design is shown to match the requirements on the Beam Calorimeter performance. Studies of polycrystalline chemical vapour deposition (pCVD) diamond as a sensor material for the Beam Calorimeter are done to explore the properties of the material. Results of the measurements performed with pCVD diamond samples produced by different manufacturers are presented. (orig.)

  20. Measurements of beam emittance, accelerated RF phase band, and centring in a 1 MeV test cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Dehnel, M.P.; Erdman, K.L. [Obco Technologies Inc., Richmond B.C. (Canada); Kuo, T. [TRIUMF, Vancouver B.C. (Canada)

    1999-07-01

    Differential probe measurements of radial and axial circulating beam intensity in the EBCO/TRIUMF 1 MeV H{sup -} Test Cyclotron have been made. Intensity profile simulations from an analytical model compare well with the measured beam intensity data, and yield important beam related quantities such as the emittance, the accelerated RF phase band and the beam centring. The experimental hardware details, comparisons of measured and computed data, and a description of the analytical model are reported. (authors)

  1. Electron beam test of key elements of the laser-based calibration system for the muon g - 2 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Anastasi, A.; Basti, A.; Bedeschi, F.; Bartolini, M.; Cantatore, G.; Cauz, D.; Corradi, G.; Dabagov, S.; Di Sciascio, G.; Di Stefano, R.; Driutti, A.; Escalante, O.; Ferrari, C.; Fienberg, A. T.; Fioretti, A.; Gabbanini, C.; Gioiosa, A.; Hampai, D.; Hertzog, D. W.; Iacovacci, M.; Karuza, M.; Kaspar, J.; Liedl, A.; Lusiani, A.; Marignetti, F.; Mastroianni, S.; Moricciani, D.; Pauletta, G.; Piacentino, G. M.; Raha, N.; Rossi, E.; Santi, L.; Venanzoni, G.

    2017-01-01

    We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.

  2. Preliminary X-43 flight test results

    Science.gov (United States)

    McClinton, Charles R.; Rausch, Vincent L.; Nguyen, Luat T.; Sitz, Joel R.

    2005-07-01

    The successful Mach 7 flight test of the Hyper-X/X-43 research vehicle has provided a major, essential demonstration of the capability of the airframe integrated scramjet engine. This flight was a crucial first step toward establishing the potential for air-breathing hypersonic propulsion for application to space-launch vehicles.

  3. Beam-loss-induced electrical stress test on CMS Silicon Strip Modules

    CERN Document Server

    Fahrer, M; Hartmann, F; Heier, S; MacPherson, A; Muller, T H; Weiler, T h

    2004-01-01

    Based on simulated LHC beam loss scenarios, fully depleted CMS silicon tracker modules and sensors were exposed to 42 ns-long beam spills of approximately 10**1**1 protons per spill at the PS at CERN. The ionisation dose was sufficient to short circuit the silicon sensors. The dynamic behaviour of bias voltage, leakage currents and voltages over coupling capacitors were monitored during the impact. Results of pre- and post-qualification as well as the dynamic behaviour are shown.

  4. Linear and second order optics corrections for the KEK Accelerator Test Facility final focus beam line

    Directory of Open Access Journals (Sweden)

    T. Okugi

    2014-02-01

    Full Text Available In this paper, the linear and second order optics corrections for the KEK Accelerator Test Facility (ATF2 final focus beam line are described. The beam optics of the ATF2 beam line is designed based on a local chromaticity correction scheme similar to the ILC final focus system. Beam measurements in 2012 revealed skew sextupole field errors that were much larger than expected from magnetic field measurements. The skew sextupole field error was a critical limitation of the beam size at the ATF2 virtual interaction point (IP. Therefore, four skew sextupole magnets were installed to correct the field error in August 2012. By using the four skew sextupole magnets, the predicted tolerances of the skew sextupole field errors of the ATF2 magnets were increased. Furthermore, analyzing field maps of the sextupole magnets identified the source of the skew sextupole field error. After the field error source was removed, the IP vertical beam size could more easily be focused to less than 65 nm.

  5. Validation of the Read Out Electronics for the CMS Muon Drift Chambers at Tests Beam in CERN/GIF

    CERN Document Server

    Fernández, C; Fouz-Iglesias, M C; Marin, J; Oller, J C; Willmott, C

    2002-01-01

    Part of the readout system for the CMS muon drift chambers has been tested in test beams at CERN/GIF. Read Out Board (ROB) and HPTD have been validated with signals from a real muon beam, with an structure and flux similar to LHC operating conditions and using one of the chambers produced in CIEMAT already located in the test beam area under normal gas and voltage conditions. (Author) 5 refs.

  6. A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, P. [Cockcroft Inst. Accel. Sci. Tech.; Baboi, N. [DESY; Eddy, N. [Fermilab; Fellenz, B. [Fermilab; Jones, R. M. [Cockcroft Inst. Accel. Sci. Tech.; Lorbeer, B. [DESY; Wamsat, T. [DESY; Wendt, M. [Fermilab

    2012-08-01

    Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to define a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 {\\mu}m accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 {\\mu}m over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012.

  7. A study of beam position diagnostics with beam-excited dipole higher order modes using a downconverter test electronics in third harmonic 3.9 GHz superconducting accelerating cavities at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, P. [Manchester Univ. (United Kingdom); Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Baboi, N.; Lorbeer, B.; Wamsat, T. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Eddy, N.; Fellenz, B.; Wendt, M. [Fermi National Accelerator Lab., Batavia, IL (United States); Jones, R.M. [Manchester Univ. (United Kingdom); The Cockcroft Institute, Daresbury (United Kingdom)

    2012-08-15

    Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to de ne a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 m accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 m over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012.

  8. A layer correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test

    Science.gov (United States)

    Abat, E.; Abdallah, J. M.; Addy, T. N.; Adragna, P.; Aharrouche, M.; Ahmad, A.; Akesson, T. P. A.; Aleksa, M.; Alexa, C.; Anderson, K.; Andreazza, A.; Anghinolfi, F.; Antonaki, A.; Arabidze, G.; Arik, E.; Atkinson, T.; Baines, J.; Baker, O. K.; Banfi, D.; Baron, S.; Barr, A. J.; Beccherle, R.; Beck, H. P.; Belhorma, B.; Bell, P. J.; Benchekroun, D.; Benjamin, D. P.; Benslama, K.; Bergeaas Kuutmann, E.; Bernabeu, J.; Bertelsen, H.; Binet, S.; Biscarat, C.; Boldea, V.; Bondarenko, V. G.; Boonekamp, M.; Bosman, M.; Bourdarios, C.; Broklova, Z.; Burckhart Chromek, D.; Bychkov, V.; Callahan, J.; Calvet, D.; Canneri, M.; Capeáns Garrido, M.; Caprini, M.; Cardiel Sas, L.; Carli, T.; Carminati, L.; Carvalho, J.; Cascella, M.; Castillo, M. V.; Catinaccio, A.; Cauz, D.; Cavalli, D.; Cavalli Sforza, M.; Cavasinni, V.; Cetin, S. A.; Chen, H.; Cherkaoui, R.; Chevalier, L.; Chevallier, F.; Chouridou, S.; Ciobotaru, M.; Citterio, M.; Clark, A.; Cleland, B.; Cobal, M.; Cogneras, E.; Conde Muino, P.; Consonni, M.; Constantinescu, S.; Cornelissen, T.; Correard, S.; Corso Radu, A.; Costa, G.; Costa, M. J.; Costanzo, D.; Cuneo, S.; Cwetanski, P.; Da Silva, D.; Dam, M.; Dameri, M.; Danielsson, H. O.; Dannheim, D.; Darbo, G.; Davidek, T.; De, K.; Defay, P. O.; Dekhissi, B.; Del Peso, J.; Del Prete, T.; Delmastro, M.; Derue, F.; Di Ciaccio, L.; Di Girolamo, B.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Dobos, D.; Dobson, M.; Dolgoshein, B. A.; Dotti, A.; Drake, G.; Drasal, Z.; Dressnandt, N.; Driouchi, C.; Drohan, J.; Ebenstein, W. L.; Eerola, P.; Efthymiopoulos, I.; Egorov, K.; Eifert, T. F.; Einsweiler, K.; El Kacimi, M.; Elsing, M.; Emelyanov, D.; Escobar, C.; Etienvre, A. I.; Fabich, A.; Facius, K.; Fakhr-Edine, A. I.; Fanti, M.; Farbin, A.; Farthouat, P.; Fassouliotis, D.; Fayard, L.; Febbraro, R.; Fedin, O. L.; Fenyuk, A.; Fergusson, D.; Ferrari, P.; Ferrari, R.; Ferreira, B. C.; Ferrer, A.; Ferrere, D.; Filippini, G.; Flick, T.; Fournier, D.; Francavilla, P.; Francis, D.; Froeschl, R.; Froidevaux, D.; Fullana, E.; Gadomski, S.; Gagliardi, G.; Gagnon, P.; Gallas, M.; Gallop, B. J.; Gameiro, S.; Gan, K. K.; Garcia, R.; Garcia, C.; Gavrilenko, I. L.; Gemme, C.; Gerlach, P.; Ghodbane, N.; Giakoumopoulou, V.; Giangiobbe, V.; Giokaris, N.; Glonti, G.; Goettfert, T.; Golling, T.; Gollub, N.; Gomes, A.; Gomez, M. D.; Gonzalez-Sevilla, S.; Goodrick, M. J.; Gorfine, G.; Gorini, B.; Goujdami, D.; Grahn, K.-J.; Grenier, P.; Grigalashvili, N.; Grishkevich, Y.; Grosse-Knetter, J.; Gruwe, M.; Guicheney, C.; Gupta, A.; Haeberli, C.; Haertel, R.; Hajduk, Z.; Hakobyan, H.; Hance, M.; Hansen, J. D.; Hansen, P. H.; Hara, K.; Harvey, A., Jr.; Hawkings, R. J.; Heinemann, F. E. W.; Henriques Correia, A.; Henss, T.; Hervas, L.; Higon, E.; Hill, J. C.; Hoffman, J.; Hostachy, J. Y.; Hruska, I.; Hubaut, F.; Huegging, F.; Hulsbergen, W.; Hurwitz, M.; Iconomidou-Fayard, L.; Jansen, E.; Jen-La Plante, I.; Johansson, P. D. C.; Jon-And, K.; Joos, M.; Jorgensen, S.; Joseph, J.; Kaczmarska, A.; Kado, M.; Karyukhin, A.; Kataoka, M.; Kayumov, F.; Kazarov, A.; Keener, P. T.; Kekelidze, G. D.; Kerschen, N.; Kersten, S.; Khomich, A.; Khoriauli, G.; Khramov, E.; Khristachev, A.; Khubua, J.; Kittelmann, T. H.; Klingenberg, R.; Klinkby, E. B.; Kodys, P.; Koffas, T.; Kolos, S.; Konovalov, S. P.; Konstantinidis, N.; Kopikov, S.; Korolkov, I.; Kostyukhin, V.; Kovalenko, S.; Kowalski, T. Z.; Krüger, K.; Kramarenko, V.; Kudin, L. G.; Kulchitsky, Y.; Lacasta, C.; Lafaye, R.; Laforge, B.; Lampl, W.; Lanni, F.; Laplace, S.; Lari, T.; Le Bihan, A.-C.; Lechowski, M.; Ledroit-Guillon, F.; Lehmann, G.; Leitner, R.; Lelas, D.; Lester, C. G.; Liang, Z.; Lichard, P.; Liebig, W.; Lipniacka, A.; Lokajicek, M.; Louchard, L.; Lourerio, K. F.; Lucotte, A.; Luehring, F.; Lund-Jensen, B.; Lundberg, B.; Ma, H.; Mackeprang, R.; Maio, A.; Maleev, V. P.; Malek, F.; Mandelli, L.; Maneira, J.; Mangin-Brinet, M.; Manousakis, A.; Mapelli, L.; Marques, C.; Garcia, S. Marti i.; Martin, F.; Mathes, M.; Mazzanti, M.; McFarlane, K. W.; McPherson, R.; Mchedlidze, G.; Mehlhase, S.; Meirosu, C.; Meng, Z.; Meroni, C.; Mialkovski, V.; Mikulec, B.; Milstead, D.; Minashvili, I.; Mindur, B.; Mitsou, V. A.; Moed, S.; Monnier, E.; Moorhead, G.; Morettini, P.; Morozov, S. V.; Mosidze, M.; Mouraviev, S. V.; Moyse, E. W. J.; Munar, A.; Myagkov, A.; Nadtochi, A. V.; Nakamura, K.; Nechaeva, P.; Negri, A.; Nemecek, S.; Nessi, M.; Nesterov, S. Y.; Newcomer, F. M.; Nikitine, I.; Nikolaev, K.; Nikolic-Audit, I.; Ogren, H.; Oh, S. H.; Oleshko, S. B.; Olszowska, J.; Onofre, A.; Padilla Aranda, C.; Paganis, S.; Pallin, D.; Pantea, D.; Paolone, V.; Parodi, F.; Parsons, J.; Parzhitskiy, S.; Pasqualucci, E.; Passmored, S. M.; Pater, J.; Patrichev, S.; Peez, M.; Perez Reale, V.; Perini, L.; Peshekhonov, V. D.; Petersen, J.; Petersen, T. C.; Petti, R.; Phillips, P. W.; Pina, J.; Pinto, B.; Podlyski, F.; Poggioli, L.; Poppleton, A.; Poveda, J.; Pralavorio, P.; Pribyl, L.; Price, M. J.; Prieur, D.; Puigdengoles, C.; Puzo, P.; RØhne, O.; Ragusa, F.; Rajagopalan, S.; Reeves, K.; Reisinger, I.; Rembser, C.; Bruckman de Renstrom, P. A.; Reznicek, P.; Ridel, M.; Risso, P.; Riu, I.; Robinson, D.; Roda, C.; Roe, S.; Rohne, O.; Romaniouk, A.; Rousseau, D.; Rozanov, A.; Ruiz, A.; Rusakovich, N.; Rust, D.; Ryabov, Y. F.; Ryjov, V.; Salto, O.; Salvachua, B.; Salzburger, A.; Sandaker, H.; Santamarina Rios, C.; Santi, L.; Santoni, C.; Saraiva, J. G.; Sarri, F.; Sauvage, G.; Says, L. P.; Schaefer, M.; Schegelsky, V. A.; Schiavi, C.; Schieck, J.; Schlager, G.; Schlereth, J.; Schmitt, C.; Schultes, J.; Schwemling, P.; Schwindling, J.; Seixas, J. M.; Seliverstov, D. M.; Serin, L.; Sfyrla, A.; Shalanda, N.; Shaw, C.; Shin, T.; Shmeleva, A.; Silva, J.; Simion, S.; Simonyan, M.; Sloper, J. E.; Smirnov, S. Yu; Smirnova, L.; Solans, C.; Solodkov, A.; Solovianov, O.; Soloviev, I.; Sosnovtsev, V. V.; Spanò, F.; Speckmayer, P.; Stancu, S.; Stanek, R.; Starchenko, E.; Straessner, A.; Suchkov, S. I.; Suk, M.; Szczygiel, R.; Tarrade, F.; Tartarelli, F.; Tas, P.; Tayalati, Y.; Tegenfeldt, F.; Teuscher, R.; Thioye, M.; Tikhomirov, V. O.; Timmermans, C. J. W. P.; Tisserant, S.; Toczek, B.; Tremblet, L.; Troncon, C.; Tsiareshka, P.; Tyndel, M.; Karagoez Unel, M.; Unal, G.; Unel, G.; Usai, G.; Van Berg, R.; Valero, A.; Valkar, S.; Valls, J. A.; Vandelli, W.; Vannucci, F.; Vartapetian, A.; Vassilakopoulos, V. I.; Vasilyeva, L.; Vazeille, F.; Vernocchi, F.; Vetter-Cole, Y.; Vichou, I.; Vinogradov, V.; Virzi, J.; Vivarelli, I.; de Vivie, J. B.; Volpi, M.; Anh, T. Vu; Wang, C.; Warren, M.; Weber, J.; Weber, M.; Weidberg, A. R.; Weingarten, J.; Wells, P. S.; Werner, P.; Wheeler, S.; Wiessmann, M.; Wilkens, H.; Williams, H. H.; Wingerter-Seez, I.; Yasu, Y.; Zaitsev, A.; Zenin, A.; Zenis, T.; Zenonos, Z.; Zhang, H.; Zhelezko, A.; Zhou, N.

    2011-06-01

    A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions impinging on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20GeV and 180GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.

  9. Results of workplace drug testing in Norway

    Directory of Open Access Journals (Sweden)

    Hilde Marie Erøy Lund

    2011-12-01

    Full Text Available Workplace drug testing is less common in Norway than in many other countries. During the period from 2000-2006, 13469 urine or blood samples from employees in the offshore industry, shipping companies and aviation industry were submitted to the Norwegian Institute of Public Health for drug testing. The samples were analysed for benzodiazepines, illicit drugs, muscle relaxants with sedating properties, opioids and z-hypnotics. In total, 2.9% of the samples were positive for one or more substances. During the study period the prevalence decreased for morphine (from 1.9% to 1.1% and increased for amphetamine (from 0.04% to 0.6%, clonazepam (from 0% to 0.1%, methamphetamine (from 0.04% to 0.6%, nitrazepam (from 0% to 0.4% and oxazepam (from 0.5% to 1.3% (p<0.05. There was no significant change in prevalence for the other substances included in the analytical programme. Illicit drugs were significantly associated with lower age (OR: 0.93, p<0.05. This study found low prevalence of drugs among employees in companies with workplace drug testing programmes in Norway.

  10. Comparative evaluation results of CMS replacement resist for e-beam reticle fabrication

    CERN Document Server

    Kobayashi, H; Asakawa, K; Yokoya, Y; Wada, T

    1999-01-01

    Looking for a CMS replacement resist is an urgent assignment for e- beam reticle fabrication, which enables us to maintain flexibility of reticle fabrications. The CMS-EX series was discontinued in 1995, and its stored resin will be used up completely soon in this year 1999. We then tried to find a replacement resist, and examined commercially available resists SEL-N1000, SEL-N1100 and ZEN4400. We studied their behavior to post-spin baking temperature, in order to bring out their potential, by investigating isolated clear pattern fidelity in details as it was the most tough one to make by a negative-working resist. This paper describes our comparative evaluation results of commercially available negative-working resists to determine a CMS- EX-S replacement for e-beam reticle fabrication. (4 refs).

  11. A Versatile Molecular Beam Epitaxy System for Low-Temperature STM: Instrument Design and Initial Results

    Science.gov (United States)

    Bowman, Adam; Ding, Hao; Jeon, Sangjun; Yazdani, Ali

    Efficient combination of molecular beam epitaxy (MBE) with scanning tunneling microscopy (STM) is essential for engineering and studying new materials with topological and superconducting properties. Particularly valuable are the capabilities to grow clean material interfaces, single monolayer films, and 2D systems with proximitized superconductivity. A new MBE system designed for STM was constructed to allow reliable ultra-high vacuum sample transfer, growth between 77 K and 1500 K, direct current sample flashing, and RHEED surface monitoring. Six Knudsen cells and electron beam evaporators allow growth of a variety of superconducting, topological, and metallic films. UHV transfer from the MBE via a vacuum suitcase can be accomplished within an hour to preserve clean surfaces. Initial low-temperature STM results on bismuth and monolayer iron selenide (FeSe) films will be presented. This work is supported by the Moore Foundation, ONR, and NSF.

  12. Protecting LHC IP1/IP5 Components Against Radiation Resulting from Colliding Beam Interactions

    CERN Document Server

    Mokhov, N V; Kerby, J S; Strait, J B

    2003-01-01

    Beam-induced energy deposition in the LHC high luminosity interaction region (IR) components due to both pp collisions and beam loss in the IR vicinity is a significant challenge for the design of the high luminosity insertions. It was shown in our previous studies that a set of absorbers would reduce both the peak power density and total heat load to tolerable levels. In this paper the results of further optimization and comprehensive MARS calculations are summarized for the LHC lattice, version 6.4, for the updated IP1 and IP5 layouts and a baseline pp-collision source term. Power density, power dissipation, particle fluxes and spectra, accumulated dose and residual dose rates are studied in the components of the inner triplets including their TAS absorbers, the TAN neutral beam absorbers, separation dipoles, and quadrupoles of the outer triplets and possible collimators there. Results are given for the nominal luminosity of 1034 cm-2 s-1. The current design is proved to provide the best safety margin under...

  13. Possibility of high efficient beam extraction from the CERN SPS with a bent crystal. Simulation results

    Energy Technology Data Exchange (ETDEWEB)

    Scandale, W. [CERN, European Organization for Nuclear Research, CH-1211 Geneva 23 (Switzerland); Laboratoire de l' AccelerateurLineaire (LAL), Universite Paris SudOrsay, Orsay (France); INFN Sezione di Roma, Piazzale Aldo Moro 2, 00185 Rome (Italy); Kovalenko, A.D.; Taratin, A.M. [Joint Institute for Nuclear Research, 141980 Dubna, Moscow Region (Russian Federation)

    2017-03-11

    The extraction of the SPS beam of 270 GeV/c protons assisted by a bent crystal was studied by simulation. Two methods for delivering the SPS beam onto a crystal were considered: transverse diffusion and orbit bump of the beam. It was shown that the main condition for high efficient beam extraction with a bent crystal, which is a small divergence of the incident beam, can be fulfilled. Extraction efficiency up to 99% can be reached for both methods of the beam delivering. The irradiation of the electrostatic septum wires during the beam extraction can be considerably reduced.

  14. Clinical results of proton-beam therapy for locoregionally advanced esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mizumoto, Masashi; Sugahara, Shinji; Nakayama, Hidetsugu; Okumura, Toshiyuki; Tsuboi, Koji; Sakurai, Hideyuki [Proton Medical Research Center, Univ. of Tsukuba, Ibaraki (Japan); Dept. of Radiation Oncology, Univ. of Tsukuba, Ibaraki (Japan); Hashii, Haruko [Dept. of Radiation Oncology, Univ. of Tsukuba, Ibaraki (Japan); Nakahara, Akira [Dept. of Gastroenterological Medicine, Univ. of Tsukuba, Ibaraki (Japan); Terashima, Hideo [Dept. of Surgery, Univ. of Tsukuba, Ibaraki (Japan); Tokuuye, Koichi [Proton Medical Research Center, Univ. of Tsukuba, Ibaraki (Japan); Dept. of Radiology, Tokyo Medical Univ., Shinkuku, Tokyo (Japan)

    2010-09-15

    Purpose: To evaluate the efficacy and safety of proton-beam therapy for locoregionally advanced esophageal cancer. Patients and Methods: The subjects were 51 patients with esophageal cancer who were treated between 1985 and 2005 using proton beams with or without X-rays. All but one had squamous cell carcinoma. Of the 51 patients, 33 received combinations of X-rays (median 46 Gy) and protons (median 36 GyE) as a boost. The median total dose of combined X-rays and proton radiation for these 33 patients was 80 GyE (range 70-90 GyE). The other 18 patients received proton-beam therapy alone (median 79 GyE, range 62-98 GyE). Results: Treatment interruption due to radiation-induced esophagitis or hematologic toxicity was not required for any patient. The overall 5-year actuarial survival rate for the 51 patients was 21.1% and the median survival time was 20.5 months (95% confidence interval 10.9-30.2). Of the 51 patients, 40 (78%) showed a complete response within 4 months after completing treatment and seven (14%) showed a partial response, giving a response rate of 92% (47/51). The 5-year local control rate for all 51 patients was 38.0% and the median local control time was 25.5 months (95% confidence interval 14.6-36.3). Conclusion: The results suggest that proton-beam therapy is an effective treatment for patients with locally advanced esophageal cancer. Further studies are required to determine the optimal total dose, fractionation schedules, and best combination of proton therapy with chemotherapy. (orig.)

  15. Trajectory measurements and correlations in the final focus beam line at the KEK Accelerator Test Facility

    Directory of Open Access Journals (Sweden)

    Y. Renier

    2013-06-01

    Full Text Available The Accelerator Test Facility 2 (ATF2 commissioning group aims to demonstrate the feasibility of the beam delivery system of the next linear colliders (ILC and CLIC as well as to define and to test the tuning methods. As the design vertical beam sizes of the linear colliders are about few nanometers, the stability of the trajectory as well as the control of the aberrations are very critical. ATF2 commissioning started in December 2008, and thanks to submicron resolution beam position monitors (BPMs, it has been possible to measure the beam position fluctuation along the final focus of ATF2 during the 2009 runs. The optics was not the nominal one yet, with a lower focusing to make the tuning easier. In this paper, a method to measure the noise of each BPM every pulse, in a model-independent way, will be presented. A method to reconstruct the trajectory’s fluctuations is developed which uses the previously determined BPM resolution. As this reconstruction provides a measurement of the beam energy fluctuations, it was also possible to measure the horizontal and vertical dispersion function at each BPMs parasitically. The spatial and angular dispersions can be fitted from these measurements with uncertainties comparable with usual measurements.

  16. Pulsed Supersonic Beams from High Pressure Source: Simulation Results and Experimental Measurements

    Directory of Open Access Journals (Sweden)

    U. Even

    2014-01-01

    Full Text Available Pulsed beams, originating from a high pressure, fast acting valve equipped with a shaped nozzle, can now be generated at high repetition rates and with moderate vacuum pumping speeds. The high intensity beams are discussed, together with the skimmer requirements that must be met in order to propagate the skimmed beams in a high-vacuum environment without significant disruption of the beam or substantial increases in beam temperature.

  17. RESULTS OF INITIAL AMMONIA OXIDATION TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fowley, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-12-30

    This memo presents an experimental survey of aqueous phase chemical processes to remove aqueous ammonia from waste process streams. Ammonia is generated in both the current Hanford waste flowsheet and in future waste processing. Much ammonia will be generated in the Low Activity Waste (LAW) melters.i Testing with simulants in glass melters at Catholic University has demonstrated the significant ammonia production.ii The primary reaction there is the reducing action of sugar on nitrate in the melter cold cap. Ammonia has been found to be a problem in secondary waste stabilization. Ammonia vapors are noxious and destruction of ammonia could reduce hazards to waste treatment process personnel. It is easily evolved especially when ammonia-bearing solutions are adjusted to high pH.

  18. ALICE EMCal Reconstructable Energy Non-Linearity From Test Beam Monte Carlo

    CERN Document Server

    Carter, Thomas Michael

    2017-01-01

    Calorimeters play many important roles in modern high energy physics detectors, such as event selection, triggering, and precision energy measurements. EMCal, in the case of the ALICE experiment provides triggering on high energy jets, improves jet quenching study measurement bias and jet energy resolution, and improves electron and photon measurements [3]. With the EMCal detector in the ALICE experiment taking on so many important roles, it is important to fully understand, characterize and model its interactions with particles. In 2010 SPS and PS electron test beam measurements were performed on an EMCal mini-module [2]. Alongside this, the test beam setup and geometry was recreated in Geant4 by Nico [1]. Figure 1 shows the reconstructable energy linearity for the SPS test beam data and that obtained from the test beam monte carlo, indicating the amount of energy deposit as hits in the EMCal module. It can be seen that for energies above ∼ 100 GeV there is a significant drop in the reconstructableenergym...

  19. Design and Application of a Beam Testing System for Experiential Learning in Mechanics of Materials

    Science.gov (United States)

    Sullivan, R. Warsi; Rais-Rohani, M.

    2009-01-01

    Research shows that students can significantly improve their understanding and retention of topics presented in an engineering course when discussions of theoretical and mathematical approaches are combined with active-learning exercises involving hands-on physical experiments. In this paper, the design and application of a beam testing system…

  20. Facility for the testing of the TFTR prototype neutral beam injector

    Energy Technology Data Exchange (ETDEWEB)

    Haughian, J.M.

    1977-07-01

    The design of the prototype neutral beam injection system for TFTR is nearing completion at the Lawrence Livermore Laboratory. This paper describes some of the features of the facility at the Lawrence Berkeley Laboratory where this prototype will be assembled and tested.

  1. MARINET experiment KNSWING testing an I-Beam OWC attenuator

    DEFF Research Database (Denmark)

    Nielsen, Kim; Bingham, Harry B.

    2015-01-01

    energy converter with 20 Oscillating Water Column (OWC) chambers on each side. The damping applied to each chamber by the Power Take Off (PTO) is modeled by forcing the air through a hole with an area of about 1.3% of the chamber water surface area.The results in irregular wave conditions shows...... that the converter can absorb more than 2.5. MW of wave power that in wave conditions with significant wave heights of 5. m. A capture width ratio between 20% and 25% was measured in the most frequent wave conditions with average periods between 5 and 7. s with significant wave height of 2 m. In short crested waves...

  2. Experimental results of an rf gun and the generation of a multibunch beam

    Directory of Open Access Journals (Sweden)

    Abhay Deshpande

    2011-06-01

    Full Text Available At the laser undulator compact x-ray source at KEK, our group has designed and built a new rf gun with a larger mode separation of 8.6 MHz and higher Q value than earlier guns. This paper presents details on the design and fabrication, low-power measurements, and tuning procedures followed in the fabrication of the gun cavity. We also give a detailed account of experiments performed with this gun and present measurement results. We have successfully generated 100 bunches per train with a 50 nC charge at 41 MeV and 300 bunches per train with a 160 nC charge at 5 MeV, with low peak-to-peak energy difference. In the future, we plan to go up to a 0.5 nC charge per bunch in an 8000-bunch train at low energy and a 2 nC charge per bunch in a 100-bunch train at high energy. This will make it possible to have higher charge available for laser-beam collisions, thus enabling the generation of high flux soft x rays using the low-energy electron beam and approximately 30 keV x rays using the high-energy electron beam.

  3. RC Beams Strengthened with Mechanically Fastened Composites: Experimental Results and Numerical Modeling

    Directory of Open Access Journals (Sweden)

    Enzo Martinelli

    2014-03-01

    Full Text Available The use of mechanically-fastened fiber-reinforced polymer (MF-FRP systems has recently emerged as a competitive solution for the flexural strengthening of reinforced concrete (RC beams and slabs. An overview of the experimental research has proven the effectiveness and the potentiality of the MF-FRP technique which is particularly suitable for emergency repairs or when the speed of installation and immediacy of use are imperative. A finite-element (FE model has been recently developed by the authors with the aim to simulate the behavior of RC beams strengthened in bending by MF-FRP laminates; such a model has also been validated by using a wide experimental database collected from the literature. By following the previous study, the FE model and the assembled database are considered herein with the aim of better exploring the influence of some specific aspects on the structural response of MF-FRP strengthened members, such as the bearing stress-slip relationship assumed for the FRP-concrete interface, the stress-strain law considered for reinforcing steel rebars and the cracking process in RC members resulting in the well-known tension stiffening effect. The considerations drawn from this study will be useful to researchers for the calibration of criteria and design rules for strengthening RC beams through MF-FRP laminates.

  4. Long term creep tests on timber beams in heated and non-heated environments

    Energy Technology Data Exchange (ETDEWEB)

    Gowda, S.; Kortesmaa, M.; Ranta-Maunus, A. [VTT Building Technology, Espoo (Finland). Building Materials and Products

    1996-12-31

    The aim of this research investigation was to study the long term effect of creep on different wood materials under natural environmental conditions. The tests were initiated in the summer of 1992 and the results collected until the end of 1995 are reported here. The experiments on sawn timber of pine and spruce, glulam, Kerto-LVL and I-profile with hard board web structural size members were carried out in a sheltered environment, where the changes in moisture and temperature of the surrounding followed the natural climatic conditions of Southern Finland. In addition, separate tests on eight glulam beams were carried out in a heated room environment. The experiments were carried out at low load levels (2-7 MPa). The surface of few groups of specimens were treated with alkyd and emulsion paint, some were creosoted and salt impregnated, while few samples had no treatment. The creep test data of all specimens were analysed systematically to obtain creep curves. The data showed significant variation in creep among wood materials with different treatments. Creep of glulam was same in heated and non-heated environment. (orig.) (3 refs.)

  5. Middleware for big data processing: test results

    Science.gov (United States)

    Gankevich, I.; Gaiduchok, V.; Korkhov, V.; Degtyarev, A.; Bogdanov, A.

    2017-12-01

    Dealing with large volumes of data is resource-consuming work which is more and more often delegated not only to a single computer but also to a whole distributed computing system at once. As the number of computers in a distributed system increases, the amount of effort put into effective management of the system grows. When the system reaches some critical size, much effort should be put into improving its fault tolerance. It is difficult to estimate when some particular distributed system needs such facilities for a given workload, so instead they should be implemented in a middleware which works efficiently with a distributed system of any size. It is also difficult to estimate whether a volume of data is large or not, so the middleware should also work with data of any volume. In other words, the purpose of the middleware is to provide facilities that adapt distributed computing system for a given workload. In this paper we introduce such middleware appliance. Tests show that this middleware is well-suited for typical HPC and big data workloads and its performance is comparable with well-known alternatives.

  6. A test beam set-up for the characterization of the Geiger-mode avalanche photodiode technology for particle tracking

    CERN Document Server

    Vilella, A; Trenado, J; Vila, A; Casanova, R; Vos, M; Garrido, L; Dieguez, A

    2012-01-01

    It is well known that avalanche photodiodes operated in the Geiger mode above the breakdown voltage offer a virtually infinite gain and time accuracy in the picosecond range that can be used for single photon detection. However, their performance in particle detection still remains unexplored. In this contribution, we are going to expose different steps that we have taken in order to prove the efficiency of the Geiger mode avalanche photodiodes in the aforementioned field. In particular, we will present a setup for the characterization of these sensors in a test beam. The expected results of the test beam at DESY and CERN have been simulated with Geant4 and will also be exposed.

  7. Mine safety sensors: Test results in a simulated test stope

    CSIR Research Space (South Africa)

    Dickens, J

    2013-10-01

    Full Text Available in a simulated test stope John Dickens and Ruth Teleka CSIR Centre for Mining Innovation Johannesburg, South Africa Email: jdickens@csir.co.za Abstract—The South African mining industry is plagued by accidents, the most common of which are rock falls..., the locking mechanism and the wooden hanging-wall supports. The final structure included a simulated stope face in addition to the parts shown in the concept. The simulated stope face can be seen on the right of the stope in Fig. 2. 2 37 5 6 4 1 Fig. 1. A...

  8. Effects of T-tabs and large deflections in double cantilever beam specimen tests

    Science.gov (United States)

    Naik, Rajiv A.; Crews, John H., Jr.; Shivakumar, Kunigal N.

    1991-01-01

    A simple strength of materials analysis was developed for a double-cantilever beam (DCB) specimen to account for geometric nonlinearity effects due to large deflections and T-tabs. A new DCB data analysis procedure was developed to include the effects of these nonlinearities. The results of the analysis were evaluated by DCB tests performed for materials having a wide range of toughnesses. The materials used in the present study were T300/5208, IM7/8551-7, and AS4/PEEK. Based on the present analysis, for a typical deflection/crack length ratio of 0.3 (for AS4/PEEK), T-tabs and large deflections cause a 15 and 3 percent error, respectively, in the computer Mode I strain energy release rate. Design guidelines for DCB specimen thickness and T-tab height were also developed in order to keep errors due to these nonlinearities within 2 percent. Based on the test results, for both hinged and tabbed specimens, the effects of large deflection on the Mode I fracture toughness (G sub Ic) were almost negligible (less than 1 percent) in the case of T300/5208 and IM7/8551-7; however, AS4/PEEK showed a 2 to 3 percent effect. The effects of T-tabs G sub Ic were more significant for all the materials with T300/5208 showing a 5 percent error, IM7/8551-7 a 15 percent error, and, AS4/PEEK a 20 percent error.

  9. Results of SC proton cavity tests (B = 1 and B = 0.65)

    CERN Document Server

    Peauger, F et al

    2013-01-01

    The two superconducting cavities were carefully designed for challenging performance. They were fabricated in industry with intermediate tests and specialized processing in CEA and CNRS. The results are promising, except for a degradation of the field flatness of the low velocity cavity, after electron-beam welding. This might reduce the accelerating gradient. Due to delays in manufacturing, the final performance tests will be carried out in the coming months.

  10. Cavity beam position monitor system for the Accelerator Test Facility 2

    Directory of Open Access Journals (Sweden)

    Y. I. Kim

    2012-04-01

    Full Text Available The Accelerator Test Facility 2 (ATF2 is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1  μm for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.

  11. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Planck Collaboration,; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    on the measurements performed during Jupiter observations. By stacking the data from Jupiter transits, the main beam profiles are measured down to -20 dB at 30 and 44 GHz, and down to -25 dB at 70 GHz. The main beam solid angles are determined to better than 0.2% at each LFI frequency band. To ensure...... can be reached by the Jupiter measurements themselves. The agreement between the simulated beams and the scanning beams is better than 1% at each LFI frequency band. The simulated beams are used for the computation of the window functions for the effective beams. The error budget in the window...

  12. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Planck Collaboration,; Aghanim, N.; Armitage-Caplan, C.

    2014-01-01

    on the measurements performed during Jupiter observations. By stacking the data from Jupiter transits, the main beam profiles are measured down to -20 dB at 30 and 44 GHz, and down to -25 dB at 70 GHz. The main beam solid angles are determined to better than 0.2% at each LFI frequency band. To ensure...... can be reached by the Jupiter measurements themselves. The agreement between the simulated beams and the scanning beams is better than 1% at each LFI frequency band. The simulated beams are used for the computation of the window functions for the effective beams. The error budget in the window...

  13. Status and Planned Experiments of the Hiradmat Pulsed Beam Material Test Facility at CERN SPS

    Energy Technology Data Exchange (ETDEWEB)

    Charitonidis, Nikolaos [CERN; Efthymiopoulos, Ilias [CERN; Fabich, Adrian [CERN; Meddahi, Malika [CERN; Gianfelice-Wendt, Eliana [Fermilab

    2015-06-01

    HiRadMat (High Irradiation to Materials) is a facility at CERN designed to provide high-intensity pulsed beams to an irradiation area where material samples as well as accelerator component assemblies (e.g. vacuum windows, shock tests on high power targets, collimators) can be tested. The beam parameters (SPS 440 GeV protons with a pulse energy of up to 3.4 MJ, or alternatively lead/argon ions at the proton equivalent energy) can be tuned to match the needs of each experiment. It is a test area designed to perform single pulse experiments to evaluate the effect of high-intensity pulsed beams on materials in a dedicated environment, excluding long-time irradiation studies. The facility is designed for a maximum number of 1016 protons per year, in order to limit the activation of the irradiated samples to acceptable levels for human intervention. This paper will demonstrate the possibilities for research using this facility and go through examples of upcoming experiments scheduled in the beam period 2015/2016.

  14. Status and Planned Experiments of the Hiradmat Pulsed Beam Material Test Facility at CERN SPS

    CERN Document Server

    Charitonidis, Nikolaos; Fabich, Adrian; Meddahi, Malika; Gianfelice-Wendt, Eliana

    2015-01-01

    HiRadMat (High Irradiation to Materials) is a facility at CERN designed to provide high-intensity pulsed beams to an irradiation area where material samples as well as accelerator component assemblies (e.g. vacuum windows, shock tests on high power targets, collimators) can be tested. The beam parameters (SPS 440 GeV protons with a pulse energy of up to 3.4 MJ, or alternatively lead/argon ions at the proton equivalent energy) can be tuned to match the needs of each experiment. It is a test area designed to perform single pulse experiments to evaluate the effect of high-intensity pulsed beams on materials in a dedicated environment, excluding long-time irradiation studies. The facility is designed for a maximum number of 1016 protons per year, in order to limit the activation of the irradiated samples to acceptable levels for human intervention. This paper will demonstrate the possibilities for research using this facility and go through examples of upcoming experiments scheduled in the beam period 2015/201...

  15. Development of a Beam-based Phase Feedforward Demonstration at the CLIC Test Facility (CTF3)

    CERN Document Server

    AUTHOR|(CDS)2083344; Christian, Glenn

    The Compact Linear Collider (CLIC) is a proposal for a future linear electron--positron collider that could achieve collision energies of up to 3~TeV. In the CLIC concept the main high energy beam is accelerated using RF power extracted from a high intensity drive beam, achieving an accelerating gradient of 100~MV/m. This scheme places strict tolerances on the drive beam phase stability, which must be better than $0.2^\\circ$ at 12~GHz. To achieve the required phase stability CLIC proposes a high bandwidth (${>}17.5$~MHz), low latency drive beam ``phase feedforward'' (PFF) system. In this system electromagnetic kickers, powered by 500~kW amplifiers, are installed in a chicane and used to correct the phase by deflecting the beam on to longer or shorter trajectories. A prototype PFF system has been installed at the CLIC Test Facility, CTF3; the design, operation and commissioning of which is the focus of this work. Two kickers have been installed in the pre-existing chicane in the TL2 transfer line at CTF3 for t...

  16. Energy Linearity and Resolution of the ATLAS Electromagnetic Barrel Calorimeter in an Electron Test-Beam

    CERN Document Server

    Aharrouche, M; Di Ciaccio, L; El-Kacimi, M; Gaumer, O; Gouanère, M; Goujdami, D; Lafaye, R; Laplace, S; Le Maner, C; Neukermans, L; Perrodo, P; Poggioli, L; Prieur, D; Przysiezniak, H; Sauvage, G; Tarrade, F; Wingerter-Seez, I; Zitoun, R; Lanni, F; Ma, H; Rajagopalan, S; Rescia, S; Takai, H; Belymam, A; Benchekroun, D; Hakimi, M; Hoummada, A; Barberio, E; Gao, Y S; Lü, L; Stroynowski, R; Aleksa, Martin; Beck-Hansen, J; Carli, T; Efthymiopoulos, I; Fassnacht, P; Follin, F; Gianotti, F; Hervás, L; Lampl, W; Collot, J; Hostachy, J Y; Ledroit-Guillon, F; Martin, P; Ohlsson-Malek, F; Saboumazrag, S; Leltchouk, M; Parsons, J A; Seman, M; Simion, S; Banfi, D; Carminati, L; Cavalli, D; Costa, G; Delmastro, M; Fanti, M; Mandelli, L; Mazzanti, M; Tartarelli, F; Bourdarios, C; Fayard, L; Fournier, D; Graziani, G; Hassani, S; Iconomidou-Fayard, L; Kado, M; Lechowski, M; Lelas, M; Parrour, G; Puzo, P; Rousseau, D; Sacco, R; Serin, L; Unal, G; Zerwas, D; Camard, A; Lacour, D; Laforge, B; Nikolic-Audit, I; Schwemling, P; Ghazlane, H; Cherkaoui-El-Moursli, R; Idrissi Fakhr-Eddine, A; Boonekamp, M; Kerschen, N; Mansoulié, B; Meyer, P; Schwindling, J; Lund-Jensen, B; Tayalati, Y

    2006-01-01

    A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to 245 GeV. The electron beam impinged at one point corresponding to a pseudo-rapidity of eta=0.687 and an azimuthal angle of phi=0.28 in the ATLAS coordinate system. A detailed study of several effects biasing the electron energy measurement allowed an energy reconstruction procedure to be developed that ensures a good linearity and a good resolution. Use is made of detailed Monte Carlo simulations based on Geant which describe the longitudinal and transverse shower profiles as well as the energy distributions. For electron energies between 15 GeV and 180 GeV the deviation of the measured incident electron energy over the beam energy is within 0.1%. The systematic uncertainty of the measurement is about 0.1% at low energies and negligible at high energies. The energy resoluti...

  17. First on-line results from the CRIS (Collinear Resonant Ionisation Spectroscopy) beam line at ISOLDE

    Energy Technology Data Exchange (ETDEWEB)

    Procter, T. J., E-mail: thomas.procter@postgrad.manchester.ac.uk; Flanagan, K. T. [University of Manchester (United Kingdom); Collaboration: CRIS Collaboration

    2013-04-15

    The CRIS (Collinear Resonant Ionisation Spectroscopy) experiment at the on-line isotope separator facility, ISOLDE, CERN, has been constructed for high-sensitivity laser spectroscopy measurements on radioactive isotopes. The technique determines the magnetic dipole and electric quadrupole moments, nuclear spin and changes in mean-square charge radii of exotic nuclei via measurement of their hyperfine structures and isotope shifts. In November 2011 the first on-line run was performed using the CRIS beam line, when the hyperfine structure of {sup 207}Fr was successfully measured. This paper will describe the technique and experimental setup of CRIS and present the results from the first on-line experiment.

  18. Mechanical and thermal measurements on a 11 m long beam screen in the LHC Magnet Test String during RUN 3A

    CERN Document Server

    Artoos, K; Kos, N

    1999-01-01

    Two eleven meter long beam screens were installed in the third dipole of the LHC Magnet Test String. Instrumentation was used to measure the mechanical and thermal behaviour of the screens during thermal transients and quenches. The horizontal deformation, angular displacement, heating of the screen as a result of the quench induced eddy currents and relative longitudinal displacement between beam screen and magnet end were measured.

  19. An Architecture Proposal for the ILC Test Beam Silicon Telescope at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Turqueti, M.A.; /Fermilab

    2007-04-01

    The requirements for an ILC Test Beam silicon telescope system are foreseen to be very stringent. Resolution, noise, and throughput must be carefully managed in order to provide a useful instrument for the high energy physics community to develop detector technologies for the ILC. Since the ILC Test Beam is meant to test a wide variety of different detectors, it must employ universally accepted software techniques, hardware standards and protocols as well as easy integration of hardware and software with the various clients using the system. In this paper, we describe an open modular architecture to achieve these goals, including an analysis of the entire chain of software and hardware needed to meet the requirements.

  20. Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

    Science.gov (United States)

    Lee, S. H.; Yang, B. X.; Collins, J. T.; Ramanathan, M.

    2017-02-01

    Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This paper presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

  1. Results of the High-Power Conditioning and the First Beam Acceleration of the DTL-1 for J-PARC

    CERN Document Server

    Naito, F; Chiba, J; Fukui, Y; Furukawa, K; Igarashi, Z; Ikegami, K; Ikegami, M; Kadokura, E; Kamikubota, N; Kato, T; Kawamura, M; Kobayashi, H; Kubota, C; Takasaki, E; Tanaka, H; Yamaguchi, S; Yoshino, K

    2004-01-01

    The first tank of the DTL for Japan Proton Accelerator Research Complex (J-PARC) was installed in the test facility at KEK. The DTL tank is 9.9 m in length and consists of the 76 cells. The resonant frequency of the tank is 324 MHz. After the installation of the tank, the high-power conditioning was carried out deliberately. Consequently the peak rf power of 1.3 MW (pulse repetition 50 Hz, pulse length 600 μs) was put into the tank stably. (The required power is about 1.1 MW for the designed accelerating field of 2.5 MV/m on the axis.) Following the conditioning, negative hydrogen beam, accelerated by the RFQ linac up to 3 MeV, was injected to the DTL and accelerated up to its design value of 19.7 MeV. The peak current of 30 mA was achieved with almost 100% transmission. In this paper, the conditioning history of the DTL and the result of the first beam test will be described.

  2. Standard practice for preparation and use of Bent-Beam stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers procedures for designing, preparing, and using bent-beam stress-corrosion specimens. 1.2 Different specimen configurations are given for use with different product forms, such as sheet or plate. This practice applicable to specimens of any metal that are stressed to levels less than the elastic limit of the material, and therefore, the applied stress can be accurately calculated or measured (see Note 1). Stress calculations by this practice are not applicable to plastically stressed specimens. Note 1—It is the nature of these practices that only the applied stress can be calculated. Since stress-corrosion cracking is a function of the total stress, for critical applications and proper interpretation of results, the residual stress (before applying external stress) or the total elastic stress (after applying external stress) should be determined by appropriate nondestructive methods, such as X-ray diffraction (1). 1.3 Test procedures are given for stress-corrosion testing by ex...

  3. Partial Breast Radiation Therapy With Proton Beam: 5-Year Results With Cosmetic Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Bush, David A., E-mail: dbush@llu.edu [Department of Radiation Oncology, Loma Linda University Medical Center, Loma Linda, California (United States); Do, Sharon [Department of Radiation Oncology, Loma Linda University Medical Center, Loma Linda, California (United States); Lum, Sharon; Garberoglio, Carlos [Department of Surgical Oncology, Loma Linda University Medical Center, Loma Linda, California (United States); Mirshahidi, Hamid [Department of Medical Oncology, Loma Linda University Medical Center, Loma Linda, California (United States); Patyal, Baldev; Grove, Roger; Slater, Jerry D. [Department of Radiation Oncology, Loma Linda University Medical Center, Loma Linda, California (United States)

    2014-11-01

    Purpose: We updated our previous report of a phase 2 trial using proton beam radiation therapy to deliver partial breast irradiation (PBI) in patients with early stage breast cancer. Methods and Materials: Eligible subjects had invasive nonlobular carcinoma with a maximal dimension of 3 cm. Patients underwent partial mastectomy with negative margins; axillary lymph nodes were negative on sampling. Subjects received postoperative proton beam radiation therapy to the surgical bed. The dose delivered was 40 Gy in 10 fractions, once daily over 2 weeks. Multiple fields were treated daily, and skin-sparing techniques were used. Following treatment, patients were evaluated with clinical assessments and annual mammograms to monitor toxicity, tumor recurrence, and cosmesis. Results: One hundred subjects were enrolled and treated. All patients completed the assigned treatment and were available for post-treatment analysis. The median follow-up was 60 months. Patients had a mean age of 63 years; 90% had ductal histology; the average tumor size was 1.3 cm. Actuarial data at 5 years included ipsilateral breast tumor recurrence-free survival of 97% (95% confidence interval: 100%-93%); disease-free survival of 94%; and overall survival of 95%. There were no cases of grade 3 or higher acute skin reactions, and late skin reactions included 7 cases of grade 1 telangiectasia. Patient- and physician-reported cosmesis was good to excellent in 90% of responses, was not changed from baseline measurements, and was well maintained throughout the entire 5-year follow-up period. Conclusions: Proton beam radiation therapy for PBI produced excellent ipsilateral breast recurrence-free survival with minimal toxicity. The treatment proved to be adaptable to all breast sizes and lumpectomy cavity configurations. Cosmetic results appear to be excellent and unchanged from baseline out to 5 years following treatment. Cosmetic results may be improved over those reported with photon

  4. RESULTS FROM THE COMMISSIONING OF THE NSRL BEAM TRANSFER LINE AT BNL.

    Energy Technology Data Exchange (ETDEWEB)

    TSOUPAS,N.; BELLAVIA,S.; BONATI,R.; ET AL.

    2004-07-05

    The NASA SPACE RADIATION LABORATORY (NSRL) has been constructed and started operations at the Brookhaven National Laboratory in 2003. The NSRL facility will be used by NASA to perform radiation effect studies on materials and biological samples for the space program. The facility utilizes proton and heavy-ion beams of energies from 50 to 3000 MeVln which are accelerated by the AGS Booster synchrotron accelerator. To date, {sup 1}H, {sup 12}C, {sup 56}Fe, {sup 48}Ti, and {sup 197}Au ion beams of various magnetic rigidities have been extracted from the Booster, and transported by the NSRL beam transport line to the sample location which is located 100 m from the extraction point. The NSRL beam transport line has been designed to employ octupole magnetic elements which transform the normal (Gaussian) beam distribution at the location of the sample into a beam with rectangular cross section, and uniformly distributed over the sample. When using the octupole magnetic elements to obtain the uniform beam distribution on the sample, no beam-collimation is applied at any location along the NSRL beam transport line and the beam focusing on the sample is purely magnetic. The main subject of this paper will be the performance of the octupoles (third order optics) in obtaining uniform beam distributions at the target of the NSRL beam transport line.

  5. FIRST BEAM TESTS OF THE APS MBA UPGRADE ORBIT FEEDBACK CONTROLLER

    Energy Technology Data Exchange (ETDEWEB)

    Sereno, N. S.; Arnold, N.; Brill, A.; Bui, H.; Carwardine, J.; Decker, G.; Deriy, B.; Emery, L.; Farnsworth, R.; Fors, T.; Keane, R.; Lenkszus, F.; Lill, R.; Paskvan, D.; Pietryla, A.; Shang, H.; Shoaf, S.; Veseli, S.; Wang, J.; Xu, S.; Yang, B.X.

    2017-03-25

    The new orbit feedback system required for the APS multi-bend acromat (MBA) ring must meet challenging beam stability requirements. The AC stability requirement is to correct rms beam motion to 10 % the rms beam size at the insertion device source points from 0.01 to 1000 Hz. The vertical plane represents the biggest challenge for AC stability which is required to be 400 nm rms for a 4 micron vertical beam size. In addition long term drift over a period of 7 days is required to be 1 micron or less at insertion de- vice BPMs and 2 microns for arc bpms. We present test re- sults of theMBA prototype orbit feedback controller (FBC) in the APS storage ring. In this test, four insertion device BPMs were configured to send data to the FBC for process- ing into four fast corrector setpoints. The configuration of four bpms and four fast correctors creates a 4-bump and the configuration of fast correctors is similar to what will be implemented in the MBA ring. We report on performance benefits of increasing the sampling rate by a factor of 15 to 22.6 kHz over the existing APS orbit feedback system, lim- itations due to existing storage ring hardware and extrapo- lation to theMBA orbit feedback design. FBC architecture, signal flow and processing design will also be discussed.

  6. Upgrade and experimental results of radio frequency ion source for neutral beam injector

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Yahong, E-mail: xieyh@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Hu, Chundong [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Jiang, Caichao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Graduate school, University of Science and Technology of China, Hefei 230026 (China); Gu, Yuming; Xu, Yongjian; Chen, Shiyong; Liang, Lizhen; Liu, Zhimin; Xie, Yuanlai [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2017-01-15

    Highlights: • The RF ion source was developed in ASIPP for the first time. • The gas control was employed for the initial plasma production successfully. • The RF power was controlled for the stable plasma generation with high power. • Long pulse operation was tested and analyzed with 400 s. - Abstract: A radio frequency (RF) ion source was designed and developed for neutral beam injector in Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). Recently, the RF ion source was upgraded with new RF power generator (50 kW with frequency of 1 MHz), a new matching unit and the faraday shield with water cooling. Two new methods were used for the ion source tests on the test bed. The high pressure was used for the ignition of plasma and change to low pressure of 0.3 Pa to maintain the plasma. The RF plasma can be generated without the start filament successfully. In order to avoid the plasma oscillation with high power, the RF power was set to increase with two stages without change the matching unit. High power of 46 kW with pulse length of 22 s was achieved on the test bed and the plasma duration can be extended too.

  7. Planck 2015 results. IV. Low Frequency Instrument beams and window functions

    Science.gov (United States)

    Planck Collaboration; Ade, P. A. R.; Aghanim, N.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Bartolo, N.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bock, J. J.; Bonaldi, A.; Bonavera, L.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Bucher, M.; Burigana, C.; Butler, R. C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Chamballu, A.; Christensen, P. R.; Colombi, S.; Colombo, L. P. L.; Crill, B. P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R. D.; Davis, R. J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Dickinson, C.; Diego, J. M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T. A.; Eriksen, H. K.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K. M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Hansen, F. K.; Hanson, D.; Harrison, D. L.; Henrot-Versillé, S.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Hornstrup, A.; Hovest, W.; Huffenberger, K. M.; Hurier, G.; Jaffe, A. H.; Jaffe, T. R.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kiiveri, K.; Kisner, T. S.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lähteenmäki, A.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C. R.; Leahy, J. P.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P. B.; Linden-Vørnle, M.; Lindholm, V.; López-Caniego, M.; Lubin, P. M.; Macías-Pérez, J. F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P. G.; Martínez-González, E.; Masi, S.; Matarrese, S.; Mazzotta, P.; McGehee, P.; Meinhold, P. R.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Montier, L.; Morgante, G.; Mortlock, D.; Moss, A.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C. B.; Nørgaard-Nielsen, H. U.; Novikov, D.; Novikov, I.; Paci, F.; Pagano, L.; Paoletti, D.; Partridge, B.; Pasian, F.; Patanchon, G.; Pearson, T. J.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Pierpaoli, E.; Pietrobon, D.; Pointecouteau, E.; Polenta, G.; Pratt, G. W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renzi, A.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rubiño-Martín, J. A.; Rusholme, B.; Sandri, M.; Santos, D.; Savelainen, M.; Scott, D.; Seiffert, M. D.; Shellard, E. P. S.; Spencer, L. D.; Stolyarov, V.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vassallo, T.; Vielva, P.; Villa, F.; Wade, L. A.; Wandelt, B. D.; Watson, R.; Wehus, I. K.; Yvon, D.; Zacchei, A.; Zonca, A.

    2016-09-01

    This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013 Planck release; the main differences concern the beam normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 30 and 44 GHz, and down to -30 dB at 70 GHz. It has been confirmed that the agreement between the simulated beams and the measured beams is better than 1% at each LFI frequency band (within the 20 dB contour from the peak, the rms values are 0.1% at 30 and 70 GHz; 0.2% at 44 GHz). Simulated polarized beams are used for the computation of the effective beam window functions. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer band shapes. The total uncertainties in the effective beam window functions are 0.7% and 1% at 30 and 44 GHz, respectively (at ℓ ≈ 600); and 0.5% at 70 GHz (at ℓ ≈ 1000).

  8. Production Facility Prototype Blower Installation Report with 1000 Hour Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-01

    The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was needed for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is currently being installed at the LANL facility for target and component flow testing. This report describes this blower/motor/pressure vessel package and the status of the facility preparations. The blower has been operated for 1000 hours as a preliminary investigation of long term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced. Test results and conclusions are reported.

  9. Dynamic testing of thin-walled composite box beams in a vacuum chamber

    Science.gov (United States)

    Chandra, Ramesh; Chopra, Inderjit

    1989-01-01

    Vibration characteristics of thin-walled composite box beams are measured in a rotating environment in a 10-ft diameter vacuum chamber. Symmetric and antisymmetric layup beams are fabricated out of graphite/epoxy prepreg material using an autoclave molding technique. These are excited using piezoelectric ceramic elements and responses are measured using strain gages and accelerometers. First three natural modes are identified using spectrum analyzer over a range of rotational speeds up to 1000 rpm. Measured frequencies and mode shapes (displacement as well as strain) are correlated satisfactorily with calculated finite element results.

  10. Pion Energy Reconstruction by the Local Hadronic Calibration Method with ATLAS Combined Test Beam 2004 data

    CERN Document Server

    Kulchitsky, Y; Khubua, J; Russakovich, N; Shigaev, V; Vinogradov, V

    2008-01-01

    The pion energy reconstruction by the local hadronic calibration method on the basis of the 2004 combined test beam data in the energy range 10 -- 350 GeV and $\\eta = 0.25$ is performed. In this method energies deposited in each cell are weighted. The weights are determined by the Monte Carlo simulation using Calibration Hits software. We have modified this method by applying cuts in weights. The obtained fractional energy resolution with the conventional method of determination of the energy deposit in the dead material between LAr and Tile calorimeters is $\\sigma/E = (67\\pm2)\\%/\\sqrt{E} \\oplus (3.9\\pm0.2)\\% \\oplus (95\\pm22)\\%/E$. This is about 1.5 times better than the results for the hadronic calibration method obtained by the Oxford-Stockholm group and slightly better than the H1 method results for CTB04 obtained by Pisa group. The energy linearity is within $\\pm$1\\%. We have determined the general normalization constant of 0.91 for which the mean value linearity for the weight cut of 1.05 is about 1. At ...

  11. Thermal shock tests with beryllium coupons in the electron beam facility JUDITH

    Energy Technology Data Exchange (ETDEWEB)

    Roedig, M.; Duwe, R.; Schuster, J.L.A. [Forschungszentrum Juelich GmbH (Germany)] [and others

    1995-09-01

    Several grades of American and Russian beryllium have been tested in high heat flux tests by means of an electron beam facility. For safety reasons, major modifications of the facility had to be fulfilled in advance to the tests. The influence of energy densities has been investigated in the range between 1 and 7 MJ/m{sup 2}. In addition the influence of an increasing number of shots at constant energy density has been studied. For all samples, surface profiles have been measured before and after the experiments. Additional information has been gained from scanning electron microscopy, and from metallography.

  12. Preliminary design of safety and interlock system for indian test facility of diagnostic neutral beam

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, Himanshu, E-mail: htyagi@iter-india.org [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Soni, Jignesh [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Yadav, Ratnakar; Bandyopadhyay, Mainak; Rotti, Chandramouli [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Gahlaut, Agrajit [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Joshi, Jaydeep; Parmar, Deepak [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Bansal, Gourab; Pandya, Kaushal; Chakraborty, Arun [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India)

    2016-11-15

    Highlights: • Indian Test Facility being built to characterize DNB for ITER delivery. • Interlock system required to safeguard the investment incurred in building the facility and protecting ITER deliverable components. • Interlock levels upto 3IL-3 identified. • Safety instrumented system for occupational safety being designed. Safety I&C functions of SIL-2 identified. • The systems are based on ITER PIS and PSS design guidelines. - Abstract: Indian Test Facility (INTF) is being built in Institute For Plasma Research to characterize Diagnostic Neutral Beam in co-operation with ITER Organization. INTF is a complex system which consists of several plant systems like beam source, gas feed, vacuum, cryogenics, high voltage power supplies, high power RF generators, mechanical systems and diagnostics systems. Out of these, several INTF components are ITER deliverable, that is, beam source, beam line components and power supplies. To ensure successful operation of INTF involving integrated operation of all the constituent plant systems a matured Data Acquisition and Control System (DACS) is required. The INTF DACS is based on CODAC platform following on PCDH (Plant Control Design Handbook) guidelines. The experimental phases involve application of HV power supplies (100 KV) and High RF power (∼800 KW) which will produce energetic beam of maximum power 6MW within the facility for longer durations. Hence the entire facility will be exposed tohigh heat fluxes and RF radiations. To ensure investment protection and to provide occupational safety for working personnel a matured Safety and Interlock system is required for INTF. The Safety and Interlock systems are high-reliability I&C systems devoted completely to the specific functions. These systems will be separate from the conventional DACS of INTF which will handle the conventional control and acquisition functions. Both, the Safety and Interlock systems are based on IEC 61511 and IEC 61508 standards as

  13. Beam Test Performance and Simulation of Prototypes for the ALICE Silicon Pixel Detector

    CERN Document Server

    Conrad, J; Antinori, F; Badalà, A; Barbera, R; Boccardi, A; Bruno, G E; Burns, M; Cali, I A; Campbell, M; Caselle, M; Ceresa, S; Chochula, P; Cinausero, M; Dima, R; Elia, D; Fabris, D; Fini, R A; Fioretto, E; Kapusta, S; Kluge, A; Krivda, M; Lenti, V; Librizzi, F; Lunardon, M; Manzari, V; Morel, M; Moretto, S; Morsch, A; Nilsson, P; Noriega, M L; Osmic, F; Pappalardo, G S; Paticchio, V; Pepato, Adriano; Prete, G; Pulvirenti, A; Riedler, P; Riggi, F; Santoro, R; Scarlassara, F; Segato, G F; Soramel, F; Stefanini, G; Sándor, L; Torcatode-Matos, C; Turrisi, R; Vannucci, L; Viesti, G; Virgili, T

    2007-01-01

    The silicon pixel detector (SPD) of the ALICE experiment in preparation at the Large Hadron Collider (LHC) at CERN is designed to provide the precise vertex reconstruction needed for measuring heavy flavor production in heavy ion collisions at very high energies and high multiplicity. The SPD forms the innermost part of the Inner Tracking System (ITS) which also includes silicon drift and silicon strip detectors. Single assembly prototypes of the ALICE SPD have been tested at the CERN SPS using high energy proton/pion beams in 2002 and 2003. We report on the experimental determination of the spatial precision. We also report on the first combined beam test with prototypes of the other ITS silicon detector technologies at the CERN SPS in November 2004. The issue of SPD simulation is briefly discussed.

  14. Test~of~Beam~Extraction~by~Crystal~Channeling~at~the~SPS: A First Step towards a LHC Extracted Beam

    CERN Multimedia

    2002-01-01

    % RD22 \\\\ \\\\ The availability of a beam extracted out of the LHC accelerator would open up very interesting possibilities for B-physics, in particular for the study of CP-violation. Channeling in bent crystals appears to be the most promising method to produce an extracted beam of intensity $\\sim$~10$^{8}$ p/sec. This would provide as many as 10$^{10}$ $ B \\bar{B} $ pairs per year of run, two orders of magnitude more than could be produced by an e$^+$e$^-$ B-factory with L~=~10$^{34}$ cm$^{-2}$s$^{-1}$ We propose a R\\&D program to study beam extraction at the CERN SPS, using a silicon bent crystal to be installed in the SPS beam pipe and placed next to the beam in such a way as to intercept the beam halo. Transverse excitation of the beam in presence of non-linearities will be used to create halo conditions similar to what are expected for LHC.

  15. Beam tests of a prototype level-1 calorimeter trigger for LHC experiments

    Energy Technology Data Exchange (ETDEWEB)

    Brawn, I.P. (The University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Carney, R.E. (The University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Dickow, U. (CERN, 1211 Geneva 23 (Switzerland)); Eisenhandler, E. (Queen Mary and Westfield College, University of London, London, E1 4NS (United Kingdom)); Ellis, N. (CERN, 1211 Geneva 23 (Switzerland)); Garvey, J. (The University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Gee, C.N.P. (Rutherford Appleton Laboratory, Chilton, Didcot, Oxon, OX11 0QX (United Kingdom)); Gillman, A.R. (Rutherford Appleton Laboratory, Chilton, Didcot, Oxon, OX11 0QX (United Kingdom)); Hatley, R. (Rutherford Appleton Laboratory, Chilton, Didcot, Oxon, OX11 0QX (United Kingdom)); Landon, M. (Queen Mary and Westfield College, University of London, London, E1 4NS (United Kingdom)); Perera, V. (Rutherford Appleton Laboratory, Chilton, Didcot, Oxon, OX11 0QX (United Kingdom)); Quinton, S. (Rutherford Appleton Laboratory, Chilton

    1994-10-01

    Beam tests of a first-prototype electromagnetic calorimeter trigger processor for LHC experiments are described. The synchronous, pipelined, digital processor built with ASICs, was successfully operated at the full LHC bunch-crossing frequency of 40 MHz. Real data signals were obtained from a liquid argon electromagnetic calorimeter. The measured performance of the electron/photon trigger algorithm is compared with Monte Carlo simulations. ((orig.))

  16. Measurement of trapping time constants in irradiated DOFZ silicon with test beam data

    CERN Document Server

    Lari, T

    2004-01-01

    A method has been developed to measure the trapping time constants in irradiated materials with test beam data. The measurements have been performed on ATLAS pixel detectors irradiated with protons to a fluence of 1.1 * 10/sup 15/ n/sub eq/ cm/sup -2/. Different defect annealing scenarios have been investigated. The trapping probability has been observed to be smaller after 25 h of annealing at 60 degrees C than after beneficial annealing only.

  17. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  18. INTEGRATING CONTROLS FRAMEWORKS: CONTROL SYSTEMS FOR NA62 LAV DETECTOR TEST BEAMS

    CERN Document Server

    Holme, O; Golonka, P; Gonzalez-Berges, M; Milcent, H

    2011-01-01

    The detector control system for the NA62 experiment at CERN, to be ready for physics data-taking in 2014, is going to be built based on control technologies recommended by the CERN Engineering group. A rich portfolio of the technologies is planned to be showcased and deployed in the final application, and synergy between them is needed. In particular two approaches to building controls application need to play in harmony: the use of the high-level application framework called UNICOS, and a bottom-up approach of development based on the components of the JCOP Framework. The aim of combining the features provided by the two frameworks is to avoid duplication of functionality and minimize the maintenance and development effort for future controls applications. In the paper the result of the integration efforts obtained so far are presented; namely the control applications developed for beam-testing of NA62 detector prototypes. Even though the delivered applications are simple, significant conceptual and developm...

  19. Integrating Controls Frameworks: Control Systems for NA62 LAV Detector Test Beams

    CERN Document Server

    Holme, Oliver; Golonka, Piotr; Gonzalez-Berges, Manuel; Milcent, Hervé

    2011-01-01

    The detector control system for the NA62 experiment at CERN, to be ready for physics data-taking in 2014, is going to be built based on control technologies recommended by the CERN Engineering group. A rich portfolio of the technologies is planned to be showcased and deployed in the final application, and synergy between them is needed. In particular two approaches to building controls application need to play in harmony: the use of the high-level application framework called UNICOS, and a bottom-up approach of development based on the components of the JCOP Framework. The aim of combining the features provided by the two frameworks is to avoid duplication of functionality and minimize the maintenance and development effort for future controls applications. In the paper the result of the integration efforts obtained so far are presented; namely the control applications developed for beam-testing of NA62 detector prototypes. Even though the delivered applications are simple, significant conceptual and developm...

  20. Results of ASTM round robin testing for mode 1 interlaminar fracture toughness of composite materials

    Science.gov (United States)

    Obrien, T. Kevin; Martin, Roderick H.

    1992-01-01

    The results are summarized of several interlaboratory 'round robin' test programs for measuring the mode 1 interlaminar fracture toughness of advanced fiber reinforced composite materials. Double Cantilever Beam (DCB) tests were conducted by participants in ASTM committee D30 on High Modulus Fibers and their Composites and by representatives of the European Group on Fracture (EGF) and the Japanese Industrial Standards Group (JIS). DCB tests were performed on three AS4 carbon fiber reinforced composite materials: AS4/3501-6 with a brittle epoxy matrix; AS4/BP907 with a tough epoxy matrix; and AS4/PEEK with a tough thermoplastic matrix. Difficulties encountered in manufacturing panels, as well as conducting the tests are discussed. Critical issues that developed during the course of the testing are highlighted. Results of the round robin testing used to determine the precision of the ASTM DCB test standard are summarized.

  1. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    CERN Document Server

    Aghanim, N; Arnaud, M; Ashdown, M; Atrio-Barandela, F; Aumont, J; Baccigalupi, C; Banday, A J; Barreiro, R B; Battaner, E; Benabed, K; Benoît, A; Benoit-Lévy, A; Bernard, J -P; Bersanelli, M; Bielewicz, P; Bobin, J; Bock, J J; Bonaldi, A; Bond, J R; Borrill, J; Bouchet, F R; Bridges, M; Bucher, M; Burigana, C; Butler, R C; Cardoso, J -F; Catalano, A; Chamballu, A; Chiang, L -Y; Christensen, P R; Church, S; Colombi, S; Colombo, L P L; Crill, B P; Curto, A; Cuttaia, F; Danese, L; Davies, R D; Davis, R J; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Dickinson, C; Diego, J M; Dole, H; Donzelli, S; Doré, O; Douspis, M; Dupac, X; Efstathiou, G; Enßlin, T A; Eriksen, H K; Finelli, F; Forni, O; Frailis, M; Franceschi, E; Gaier, T C; Galeotta, S; Ganga, K; Giard, M; Giraud-Héraud, Y; González-Nuevo, J; Górski, K M; Gratton, S; Gregorio, A; Gruppuso, A; Hansen, F K; Hanson, D; Harrison, D; Henrot-Versillé, S; Hernández-Monteagudo, C; Herranz, D; Hildebrandt, S R; Hivon, E; Hobson, M; Holmes, W A; Hornstrup, A; Hovest, W; Huffenberger, K M; Jaffe, T R; Jaffe, A H; Jewell, J; Jones, W C; Juvela, M; Kangaslahti, P; Keihänen, E; Keskitalo, R; Kiiveri, K; Kisner, T S; Knoche, J; Knox, L; Kunz, M; Kurki-Suonio, H; Lagache, G; Lähteenmäki, A; Lamarre, J -M; Lasenby, A; Laureijs, R J; Lawrence, C R; Leahy, J P; Leonardi, R; Lesgourgues, J; Liguori, M; Lilje, P B; Lindholm, V; Linden-Vørnle, M; López-Caniego, M; Lubin, P M; Macías-Pérez, J F; Maino, D; Mandolesi, N; Maris, M; Marshall, D J; Martin, P G; Martínez-González, E; Masi, S; Matarrese, S; Matthai, F; Mazzotta, P; Meinhold, P R; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Moneti, A; Montier, L; Morgante, G; Mortlock, D; Moss, A; Munshi, D; Naselsky, P; Natoli, P; Netterfield, C B; Nørgaard-Nielsen, H U; Novikov, D; Novikov, I; O'Dwyer, I J; Osborne, S; Paci, F; Pagano, L; Paoletti, D; Partridge, B; Pasian, F; Patanchon, G; Perdereau, O; Perotto, L; Perrotta, F; Pierpaoli, E; Pietrobon, D; Plaszczynski, S; Platania, P; Pointecouteau, E; Polenta, G; Ponthieu, N; Popa, L; Poutanen, T; Pratt, G W; Prézeau, G; Prunet, S; Puget, J -L; Rachen, J P; Rebolo, R; Reinecke, M; Remazeilles, M; Ricciardi, S; Riller, T; Rocha, G; Rosset, C; Roudier, G; Rubiño-Martín, J A; Rusholme, B; Sandri, M; Santos, D; Scott, D; Seiffert, M D; Shellard, E P S; Spencer, L D; Starck, J -L; Stolyarov, V; Stompor, R; Sureau, F; Sutton, D; Suur-Uski, A -S; Sygnet, J -F; Tauber, J A; Tavagnacco, D; Terenzi, L; Toffolatti, L; Tomasi, M; Tristram, M; Tucci, M; Tuovinen, J; Türler, M; Umana, G; Valenziano, L; Valiviita, J; Van Tent, B; Varis, J; Vielva, P; Villa, F; Vittorio, N; Wade, L A; Wandelt, B D; Zacchei, A; Zonca, A

    2014-01-01

    This paper presents the characterization of the in-flight beams, the beam window functions and the associated uncertainties for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is necessary for determining the transfer function to go from the observed to the actual sky anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the reconstruction of the anisotropy power spectrum at high multipoles, whereas the sidelobes affect the low and intermediate multipoles. The in-flight assessment of the LFI main beams relies on the measurements performed during Jupiter observations. By stacking the data from multiple Jupiter transits, the main beam profiles are measured down to -20 dB at 30 and 44 GHz, and down to -25 dB at 70 GHz. The main beam solid angles are determined to better than 0.2% at each LFI frequency band. The Planck pre-launch optical model is conveniently tuned to characterize the main beams independently of any noise effects. This approac...

  2. Planck 2015 results. IV. Low Frequency Instrument beams and window functions

    CERN Document Server

    Ade, P.A.R.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartolo, N.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bock, J.J.; Bonaldi, A.; Bonavera, L.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Bucher, M.; Burigana, C.; Butler, R.C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Chamballu, A.; Christensen, P.R.; Colombi, S.; Colombo, L.P.L.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Dickinson, C.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T.A.; Eriksen, H.K.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Hansen, F.K.; Hanson, D.; Harrison, D.L.; Henrot-Versillé, S.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, A.H.; Jaffe, T.R.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kiiveri, K.; Kisner, T.S.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lähteenmäki, A.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C.R.; Leahy, J.P.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; Lindholm, V.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; Mazzotta, P.; McGehee, P.; Meinhold, P.R.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Montier, L.; Morgante, G.; Mortlock, D.; Moss, A.; Munshi, D.; Murphy, J.A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; Novikov, D.; Novikov, I.; Paci, F.; Pagano, L.; Paoletti, D.; Partridge, B.; Pasian, F.; Patanchon, G.; Pearson, T.J.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Pierpaoli, E.; Pietrobon, D.; Pointecouteau, E.; Polenta, G.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J.P.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renzi, A.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rubiño-Martín, J.A.; Rusholme, B.; Sandri}, M.; Santos, D.; Savelainen, M.; Scott, D.; Seiffert, M.D.; Shellard, E.P.S.; Spencer, L.D.; Stolyarov, V.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J.A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vassallo, T.; Vielva, P.; Villa, F.; Wade, L.A.; Wandelt, B.D.; Watson, R.; Wehus, I.K.; Yvon, D.; Zacchei, A.

    2016-01-01

    This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013 Planck release; the main differences concern the beam normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 30 and 44 GHz, and down to -30 dB at 70 GHz. The agreement between the simulated beams and the measured beams is confirmed to be better than 1% at each LFI frequency band (within the 20 dB contour from the peak, the rms values are: 0.1% at 30 and 70 GHz; 0.2% at 44 GHz). Simulated polarized beams are used for the computation of the effective beam window functions. The error budget for the window functions is estimated fro...

  3. Simulations and cold-test results of a prototype plane wave transformer linac structure

    Directory of Open Access Journals (Sweden)

    Arvind Kumar

    2002-03-01

    Full Text Available We have built a 4-cell prototype plane wave transformer (PWT linac structure. We discuss here details of the design and fabrication of the PWT linac structure. We present results from superfish and gdfidl simulations as well as cold tests, which are in good agreement with each other. We also present detailed tolerance maps for the PWT structure. We discuss beam dynamics simulation studies performed using parmela.

  4. Results of a beam dump experiment at the CERN SPS neutrino facility

    Directory of Open Access Journals (Sweden)

    T. Hansl

    1978-03-01

    Full Text Available We report results from a beam dump experiment that has been performed at the CERN SPS neutrino facility using the CDHS neutrino counter detector. Limits on dimuon and trimuon production by new penetrating neutral particles are given. A new source of prompt electron and muon neutrinos has been observed giving (1.2±0.4× 10−7 νe or νμ per incident proton with neutrino angle smaller than 1.85 mrad and Eν > 20 GeV. If these prompt neutrinos are attributed to charmed meson pair production, the inclusive DD production cross section could be of the order of 30 ωb. If axions are existing their production rate relative to π0 mesons is found to be less than 0.5 × 10−8.

  5. Testbeam results of the upgraded fast beam condition monitor at CMS

    Energy Technology Data Exchange (ETDEWEB)

    Hempel, Maria; Karacheban, Olena; Lohmann, Wolfgang [BTU, Cottbus (Germany); DESY, Zeuthen (Germany); Afanaciev, Konstantin [NCPHEP, Minsk (Belarus); Burtowy, Piotr; Ryjov, Vladimir; Zagozdzinska, Agnieszka [CERN, Geneva (Switzerland); Henschel, Hans; Lange, Wolfgang; Leonard, Jessica Lynn [DESY, Zeuthen (Germany); Levy, Itamar [Tel Aviv University, Tel Aviv (Israel); Przyborowski, Dominik [AGH-UST, Cracow (Poland); Schuwalow, Sergej; Walsh, Roberval [DESY, Hamburg (Germany)

    2016-07-01

    The Fast Beam Condition Monitor BCM1F at CMS is based on single-crystal diamond sensor with nanosecond time resolution. BCM1F delivered luminosity and machine induced background information to the CMS and LHC control room during the first running period of the LHC. A major upgrade to BCM1F was developed and built during the long shutdown of the LHC in 2014. The increased rate and the 25ns spacing should be handled with sensors subdivided by a double pad metallization and a faster new front-end ASIC. A prototype with these new components was investigated in the testbeam at DESY-II. The results are presented and also verified by Superfish simulations.

  6. Beam backgrounds in the ATLAS detector during LHC loss map tests at beta*=40cm and beta*=80cm at Ebeam=6.5 TeV

    CERN Document Server

    The ATLAS collaboration

    2017-01-01

    In this note the beam-background measurements with the ATLAS detector during lossmap tests of the LHC are described. Loss maps taken at beta*=40 cm and the normal 2015 setting of beta*=80 cm are compared. In the first case several collimator settings were explored, resulting in significant changes of beam backgrounds in ATLAS. Besides the studies of the dependence of background on collimation, which are important for optimisation of the LHC performance, these tests provide a clean environment to study the relative importance of beam halo losses on the experiment. The results show that the halo-related component of beam background in ATLAS decreases exponentially with increasing aperture of the tertiary collimators, the slope in terms of nominal sigma being about -0.5. From the data it is also shown that in normal operation conditions of LHC run 2 the beam halo losses contribute at most at the percent level to the total background, the dominant part coming from beam-gas interactions. The data are also used to ...

  7. Test beam & time resolution analysis for UFSD and CVD diamond detectors

    CERN Document Server

    Scali, Stefano

    2017-01-01

    The ever-increasing luminosity in particle physics, aimed at seeking new phenomena, has led to the need for radiation-hard detectors with a remarkable time resolution. To reach the goal several tests and data analysis has been performed but further development is still required. During my internship I have participated to the test of new sensors. After an introduction to the theoretical framework this report describes the data taking procedure using SPS beam at the H8 site in Prevessin. The second part describes the data analysis and extrapolation of the time resolution for many boards.

  8. Results of the First Performance Tests of the CMS Electromagnetic Calorimeter

    CERN Document Server

    Adzic, Petar; Almeida, Carlos; Almeida, Nuno; Anagnostou, Georgios; Anfreville, Marc; Anicin, Ivan; Antunovic, Zeljko; Asimidis, Asimakis; Auffray, Etiennette; Baccaro, Stefania; Barney, David; Barone, Luciano; Barrillon, Pierre; Bartoloni, Alessandro; Beauceron, Stephanie; Beaudette, Florian; Bell, Ken W; Benetta, Robert; Bercher, Michel; Beteva, B; Beuselinck, Raymond; Bhardwa, A; Biino, Cristina; Bimbot, Stephane; Bloch, Philippe; Blyth, Simon; Bonesini, Maurizio; Bordalo, Paula; Bornheim, Adolf; Bourotte, Jean; Britton, David; Brown, Robert M; Brunelière, Renaud; Busson, Philippe; Camporesi, Tiziano; Cartiglia, Nicolo; Cavallari, Francesca; Chamont, David; Chang, Paoti; Chang, You-Hao; Charlot, Claude; Chen, E Augustine; Chipaux, Rémi; Cockerill, David J A; Collard, Caroline; Combaret, Christophe; Costantini, Silvia; Da Silva, J C; Dafinei, Ioan; Daskalakis, Georgios; Davatz, Giovanna; De Min, Alberto; Deiters, Konrad; Dejardin, Marc; Della Negra, Rodolphe; Depasse, Pierre; Descamp, J; Dewhirst, Guy; Dhawan, Satish; Diemoz, Marcella; Dissertori, Günther; Dittmar, Michael; Djambazov, Lubomir; Dobrzynski, Ludwik; Drndarevic, Snezana; Dupanloup, Michel; Dzelalija, Mile; Ehlers, Jan; El-Mamouni, H; Peisert, Anna; Evangelou, Ioannis; Fabbro, Bernard; Faure, Jean-Louis; Fay, Jean; Ferri, Federico; Flower, Paul S; Franzoni, Giovanni; Funk, Wolfgang; Gaillac, Anne-Marie; Gargiulo, Corrado; Gascon-Shotkin, S; Geerebaert, Yannick; Gentit, François-Xavier; Ghezzi, Alessio; Gilly, Jean; Giolo-Nicollerat, Anne-Sylvie; Givernaud, Alain; Gninenko, Sergei; Go, Apollo; Godinovic, Nikola; Golubev, Nikolai; Gómez-Reino, Robert; Govoni, Pietro; Grahl, James; Gras, Philippe; Greenhalgh, Justin; Guillaud, Jean-Paul; Haguenauer, Maurice; Hamel De Montechenault, G; Hansen, Magnus; Heath, Helen F; Hill, Jack; Hobson, Peter R; Holmes, Daniel; Holzner, André; Hou, George Wei-Shu; Ille, Bernard; Ingram, Quentin; Jain, Adarsh; Janot, Patrick; Jarry, Patrick; Karar, M A; Kataria, Sushil Kumar; Katchanov, V A; Kennedy, Bruce W; Kloukinas, Kostas; Koblitz, Birger; Kokkas, Panagiotis; Korjik, M; Krasnikov, Nikolai; Krpic, Dragomir; Kyriakis, Aristotelis; Lebeau, Michel; Lecomte, Pierre; Lecoq, Paul; Lemaire, Marie-Claude; Lethuillier, Morgan; Lin, Willis; Lintern, A L; Lister, Alison; Locci, Elizabeth; Lodge, Anthony B; Longo, Egidio; Loukas, Demetrios; Lustermann, Werner; Lynch, Clare; MacKay, Catherine Kirsty; Maletic, Dimitrije; Mandjavidze, Irakli; Manthos, Nikolaos; Markou, Athanasios; Mathez, Hervé; Matveev, Viktor; Maurelli, Georges; Menichetti, Ezio; Meridiani, Paolo; Milenovic, Predrag; Milleret, Gérard; Miné, Philippe; Montecchi, Marco; Mur, Michel; Musienko, Yuri; Nardulli, Alessandro; Nash, Jordan; Neal, Homer; Nédélec, Patrick; Negri, Pietro; Nessi-Tedaldi, Francesca; Newman, Harvey B; Nikitenko, Alexander; Obertino, Maria Margherita; Ofierzynski, Radoslaw Adrian; Organtini, Giovanni; Paganini, Pascal; Paganoni, Marco; Papadopoulos, Ioannis; Paramatti, Riccardo; Pastrone, Nadia; Pauss, Felicitas; Poilleux, Patrick; Puljak, Ivica; Pullia, Antonino; Puzovic, Jovan; Ragazzi, Stefano; Ramos, Sergio; Rander, John; Ravat, Olivier; Raymond, M; Razis, Panos A; Redaelli, Nicola; Regnault, Nicolas; Renker, Dieter; Reucroft, Steve; Reymond, Jean-Marc; Reynaud, Michel; Reynaud, Serge; Romanteau, Thierry; Rondeaux, Françoise; Rosowsky, André; Rovelli, Chiara; Rusack, Roger; Rusakov, Sergey V; Ryan, Matthew John; Rykaczewski, Hans; Sakhelashvili, Tariel; Salerno, Roberto; Santos, Marcelino; Schinzel, Dietrich; Seez, Christopher; Semeniouk, Igor; Sempere-Roldan, P; Sharif, Omar; Sharp, Peter; Shepherd-Themistocleous, Claire; Shevchenko, Sergey; Shivpuri, Ram Krishen; Sidiropoulos, Georgios; Sillou, Daniel; Singovsky, Alexander; Sirois, Yves; Sirunyan, Albert M; Smith, Brian; Smith, Vincent J; Sproston, Martin; Suter, Henry; Swain, John; Tabarelli de Fatis, Tommaso; Takahashi, Maiko; Tapper, Robert J; Tcheremoukhine, Alexandre; Teixeira, Isabel; Teixeira, Joao Paulo; Teller, Olivier; Triantis, Frixos A; Troshin, Sergey; Tyurin, Nikolay; Udriot, Stève; Ueno, Koji; Uzunian, Andrey; Van Vulpen, Ivo; Varela, Joao; Vaz-Cardoso, N; Verrecchia, Patrice; Vichoudis, Paschalis; Viertel, Gert; Virdee, Tejinder; Wang, Minzu; Williams, Jennifer C; Yaselli, Ignacio; Zamiatin, Nikolai; Zelepoukine, Serguei; Zeller, Michael E; Zhang, Lin; Zhu, Kejun; Zhu, Ren-Yuan

    2006-01-01

    Performance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to validate prototypes of the new Very Front End electronics. The final versions of the monitoring and cooling systems, and of the high and low voltage regulation were used in these tests. The results are consistent with the performance targets including those for noise and overall energy resolution, required to fulfil the physics programme of CMS at the LHC.

  9. High Pressure Gas Filled RF Cavity Beam Test at the Fermilab MuCool Test Area

    Energy Technology Data Exchange (ETDEWEB)

    Freemire, Ben [Illinois Inst. of Technology, Chicago, IL (United States)

    2013-05-01

    The high energy physics community is continually looking to push the limits with respect to the energy and luminosity of particle accelerators. In the realm of leptons, only electron colliders have been built to date. Compared to hadrons, electrons lose a large amount of energy when accelerated in a ring through synchrotron radiation. A solution to this problem is to build long, straight accelerators for electrons, which has been done with great success. With a new generation of lepton colliders being conceived, building longer, more powerful accelerators is not the most enticing option. Muons have been proposed as an alternative particle to electrons. Muons lose less energy to synchrotron radiation and a Muon Collider can provide luminosity within a much smaller energy range than a comparable electron collider. This allows a circular collider to be built with higher attainable energy than any present electron collider. As part of the accelerator, but separate from the collider, it would also be possible to allow the muons to decay to study neutrinos. The possibility of a high energy, high luminosity muon collider and an abundant, precise source of neutrinos is an attractive one. The technological challenges of building a muon accelerator are many and diverse. Because the muon is an unstable particle, a muon beam must be cooled and accelerated to the desired energy within a short amount of time. This requirement places strict requisites on the type of acceleration and focusing that can be used. Muons are generated as tertiary beams with a huge phase space, so strong magnetic fields are required to capture and focus them. Radio frequency (RF) cavities are needed to capture, bunch and accelerate the muons. Unfortunately, traditional vacuum RF cavities have been shown to break down in the magnetic fields necessary for capture and focusing.

  10. A Study of Hadronic Calibration Schemes for Pion Test Beam Data in the ATLAS Forward Calorimeter

    CERN Document Server

    McCarthy, Thomas G

    The ATLAS forward calorimeters constitute a small though important fraction of the detector's calorimeter system, designed in part to accurately and precisely measure the energy of particles and jets of particles originating from the collisions of high-energy protons at the detector's centre. The application of hadronic weights, a practice common in high-energy calorimetry, provides a means of compensation for the fraction of energy which is deposited by particles in the detector, but which is invisible to the detector due to the nature of hadronic showers. Explored here are various schemes of extracting hadronic weights, as well as the application of such weights, based on pion data from the 2003 ATLAS forward calorimeter test beam. During the collection of test beam data, beams of both pions and electrons of known energy, ranging from 10 to 200 GeV, were fired at specific points of an isolated detector in order to understand its response. The improvement in noise-subtracted energy resolution with respect to...

  11. Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam

    Energy Technology Data Exchange (ETDEWEB)

    Chatrchyan, S.; et al.

    2017-09-25

    We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillator, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the signal timing for blue and green scintillators.

  12. A Layer Correlation Technique for Pion Energy Calibration at the 2004 ATLAS Combined Beam Test

    CERN Document Server

    Grahn, Karl-Johan

    2009-01-01

    A new method for calibrating the hadron response of a segmented calorimeter is developed. It is based on a principal component analysis of the calorimeter layer energy deposits, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the ATLAS calorimeters were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions impinging on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by about 20% compared to the electromagnetic scale.

  13. A Layer Correlation Technique for ATLAS Calorimetry Calibration at the 2004 ATLAS Combined Beam Test

    CERN Document Server

    Carli, T; Spanò, F; Speckmayer, P

    2008-01-01

    A method for calibrating the response of a segmented calorimeter to hadrons is developed. The ansatz is that information on longitudinal shower fluctuations gained from a principal component analysis of the layer energy depositions can improve energy resolution by correcting for hadronic invisible energy and dead material losses: projections along the eigenvectors of the correlation matrix are used as input for the calibration. The technique is used to reconstruct the energy of pions impinging on the ATLAS calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. Simulated Monte Carlo events are used to derive corrections for invisible energy lost in nuclear reactions and in dead material in front and in between the calorimeters. For pion beams with energies between 20 and 180 GeV, the particle energy is reconstructed within 3% and the resolution is improved by about 20%.

  14. Treatment result of so-called keloid with electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Masatsugu; Narabayashi, Isamu; Tatsumi, Toshiaki; Sueyoshi, Kozo; Uesugi, Yasuo; Nakata, Yasunobu; Tajima, Sadao [Osaka Medical Coll., Takatsuki (Japan)

    1999-03-01

    Between September 1993 and February 1997, 28 sites of so-called keloid (14 true keloids and 14 hypertrophic scars) were treated with electron beam irradiation. Twenty-five of these sites were treated with surgical excision followed by radiotherapy, and the other 3 sites received radiotherapy only. Irradiation by 9 MeV electron beam was performed for all patients, with a total dose of 20 Gy (10 fractions for 2 weeks). The results were evaluated at 8-49 months (Ave. 28.4 months) after treatment. Three sites treated with radiation more than 60 days after excision were excluded from evaluation of treatment response. Twenty-two of 25 sites showed complete response (CR) or partial response (PR). The control rate of total sites was 88.0%. The control rate was 92.9% in true keloids and 81.8% in hypertrophic scars. All keloid sites in the face, neck, shoulder, back and arm exhibited CR. One site of keloid in the head showed no response (NR). In 10 sites in the thoracic lesion, 8 were PR (80.0%) and 2 were NR (20.0%). In 8 sites in the abdominal lesion, 6 were CR (75.0%), 2 were PR (25.0%). All 3 non-operative sites exhibited PR. The control rate of sites treated with radiation within 14 days after keloid excision was 80.0% and that in sites treated more than 15 days after excision was 100.0%. Seven sites (7/28=25.0%) developed acute reaction, which were demonstrated erythema in the irradiated field, but this reaction was transient. Five sites (5/28=17.9%) showed hyperpigmentation indicating late reaction. The development of malignant tumor in or around the irradiated field was not shown. Postoperative electron beam irradiation was effective for so-called keloid. These data suggest that 10-fraction irradiation controls low grade of hyperpigmentation development, even though patients received a comparatively high total dose of radiotherapy. (author)

  15. Planck 2015 results: IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Ade, P. A R; Aghanim, N.; Ashdown, M.

    2016-01-01

    normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 30...

  16. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    Science.gov (United States)

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  17. Reporting Test Results to the Public: Exploring the Doughnut.

    Science.gov (United States)

    Perlman, Carole L.

    This paper examines some of the issues involved in releasing test results to the press. The first part is based on a survey of National Association of Test Directors members (72 of the 142 members completed a questionnaire on reporting test results to the public). The survey included the following: to whom are results reported; what kind of…

  18. Beam test of the upgraded ALICE ITS detector with ion beam: Study of the expected charged particle occupancy on the chip

    CERN Document Server

    Mongkolkiattichai, Jirayu

    2017-01-01

    The ALICE experiment plan to upgrade the ITS. In particular, a new high-resolution, and low mass 7-layer silicon tracker based on monolithic pixel detector In this phase of the project, beam tests of the basic component of the detector, the chip, are very important to characterize its performance. The aim of my study is to establish the expected occupancy of the new chip for ITS ALICE Upgraded in beam tests with ion beams, it will help ALICE physicists to arrange the chip in appropriated position. To provide expected occupancy, dN/dy in Au + Au collisions of AGS Experiment is used to fit by Gaussian distribution and transformed via a relation of rapidity and pseudo rapidity to occupancy which depends on radius and angle. The detector should be near area of collision as soon as possible and the angle with respect to beam line depends on beam energy, 22, 24, 42 and 84 degrees for 2, 4, 6 and 8 A GeV

  19. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  20. Experimental test accelerator: description and results of initial experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fessenden, T.; Birx, D.; Briggs, R.

    1980-06-02

    The ETA is a high current (10,000 Amp) linear induction accelerator that produces short (30 ns) pulses of electrons at 5 MeV twice per second or in bursts of 5 pulses separated by as little as one millisecond. At this time the machine has operated at 65% of its design current and 90% of the design voltage. This report contains a description of the accelerator and its diagnostics; the results of the initial year of operation; a comparison of design codes with experiments on beam transport; and a discussion of some of the special problems and their status.

  1. Technical Note: Validation of halo modeling for proton pencil beam spot scanning using a quality assurance test pattern

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Liyong, E-mail: linl@uphs.upenn.edu; Huang, Sheng; Kang, Minglei; Solberg, Timothy D.; McDonough, James E.; Ainsley, Christopher G. [Department of Radiation Oncology, University of Pennsylvania, 3400 Civic Center Boulevard, Philadelphia, Pennsylvania 19104 (United States)

    2015-09-15

    Purpose: The purpose of this paper is to demonstrate the utility of a comprehensive test pattern in validating calculation models that include the halo component (low-dose tails) of proton pencil beam scanning (PBS) spots. Such a pattern has been used previously for quality assurance purposes to assess spot shape, position, and dose. Methods: In this study, a scintillation detector was used to measure the test pattern in air at isocenter for two proton beam energies (115 and 225 MeV) of two IBA universal nozzles (UN #1 and UN #2). Planar measurements were compared with calculated dose distributions based on the weighted superposition of location-independent (UN #1) or location-dependent (UN #2) spot profiles, previously measured using a pair-magnification method and between two nozzles. Results: Including the halo component below 1% of the central dose is shown to improve the gamma-map comparison between calculation and measurement from 94.9% to 98.4% using 2 mm/2% criteria for the 115 MeV proton beam of UN #1. In contrast, including the halo component below 1% of the central dose does not improve the gamma agreement for the 115 MeV proton beam of UN #2, due to the cutoff of the halo component at off-axis locations. When location-dependent spot profiles are used for calculation instead of spot profiles at central axis, the gamma agreement is improved from 98.0% to 99.5% using 2 mm/2% criteria. The two nozzles clearly have different characteristics, as a direct comparison of measured data shows a passing rate of 89.7% for the 115 MeV proton beam. At 225 MeV, the corresponding gamma comparisons agree better between measurement and calculation, and between measurements in the two nozzles. Conclusions: In addition to confirming the primary component of individual PBS spot profiles, a comprehensive test pattern is useful for the validation of the halo component at off-axis locations, especially for low energy protons.

  2. A~Scalable~Data~Taking~System at~a~Test~Beam~for~LHC

    CERN Multimedia

    2002-01-01

    % RD-13 A Scalable Data Taking System at a Test Beam for LHC \\\\ \\\\We have installed a test beam read-out facility for the simultaneous test of LHC detectors, trigger and read-out electronics, together with the development of the supporting architecture in a multiprocessor environment. The aim of the project is to build a system which incorporates all the functionality of a complete read-out chain. Emphasis is put on a highly modular design, such that new hardware and software developments can be conveniently introduced. Exploiting this modularity, the set-up will evolve driven by progress in technologies and new software developments. \\\\ \\\\One of the main thrusts of the project is modelling and integration of different read-out architectures to provide a valuable training ground for new techniques. To address these aspects in a realistic manner, we collaborate with detector R\\&D projects in order to test higher level trigger systems, event building and high rate data transfers, once the techniques involve...

  3. Lactose Breath Test in Children: Relationship Between Symptoms During the Test and Test Results.

    Science.gov (United States)

    Glatstein, Miguel; Reif, Shimon; Scolnik, Dennis; Rom, Liat; Yerushalmy-Feler, Anat; Dali-Levy, Margalit; Cohen, Shlomi

    2016-08-17

    Lactose malabsorption affects 70% of the world population. The hydrogen breath test (HBT) is used clinically to test for this condition. The aim of our study was to describe the relationship between symptoms experienced before and during the HBT and test results. We included children who underwent the HBT in the pediatric gastroenterology unit at Dana-Dwek Children's Hospital during a 6-month period. Previous symptoms and those experienced before and after the HBT were assessed using a questionnaire and a validated pain scale. Ninety-five children were included in the study, and 66.3% had a positive HBT. Diarrhea and flatulence during the test were significantly more frequent in the group with a positive HBT compared to those with a negative test (31.7% vs. 9.4%, P = 0.016 and 69.8% vs. 40.6%, P = 0.006, respectively). The frequency of abdominal pain and bloating was similar. Diarrhea and flatulence during the HBT are the most specific symptoms of lactose intolerance. Abdominal pain should not be automatically attributed to lactose intolerance even in the presence of lactose malabsorption. Coupling the HBT with a real-time questionnaire facilitates interpretation of results and subsequent recommendations.

  4. Outgassing measurements and results used in designing the Doublet III Neutral Beam Injector System

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, R.M.; Harvey, J.

    1979-11-01

    Material vacuum properties played an important part in designing the Neutral Beam Injector System for General Atomic's Doublet III Tokamak. Low operating vacuum tank pressures were desired to keep re-ionization of the Neutral Beam to a minimum. Plasma contamination was also a major concern, hence stringent material impurity constraints were imposed. Outgassing Rate Measurement and Residual Gas Analyses were performed on different types of materials to determine if their vacuum properties were compatible with the Neutral Beam Injector System requirements.

  5. Recent results of experiments with radioactive 21Na and 7Be ion beams

    Science.gov (United States)

    Greife, U.; Livesay, J.; Jewett, C.; Chipps, K.; Sarazin, F.; Bardayan, D.; Blackmon, J.; Nesaraja, C.; Smith, M. S.; Champagne, A.; Fitzgerald, R.; Jones, K.; Thomas, J.; Kozub, R.; Buchmann, L.; Caggiano, J.; Hunter, D.; Hutcheon, D.; Olin, A.; Ottewell, D.; Rogers, J.; Ruiz, C.; Ruprecht, G.; Trinczek, M.; Vockenhuber, C.; Bishop, S.; D'Auria, J.; Lamay, M.; Liu, W.; Wrede, C.; Chatterjee, M. L.; Chen, A. A.; Pearson, J.; Engel, S.; Laird, A. M.; Gigliotti, D.; Hussein, A.

    2007-08-01

    We report here on experiments with radioactive 21Na and 7Be beams performed by Colorado School of Mines students at the ISAC facility of TRIUMF and the Holifield Radioactive Ion Beam Facility (HRIBF) of ORNL. At TRIUMF, the DRAGON recoil separator and its segmented BGO array were used to investigate higher energy resonances in the reaction H(21Na, γ)22Mg. Using the HRIBF we performed an experiment with a 7Be ion beam to measure scattering off Hydrogen and Carbon. Both elastic 7Be + p scattering and for the first time resonant inelastic scattering 7Be(p, p‧)7Be∗ were observed.

  6. Social problems of indeterminate and false positive HIV test results ...

    African Journals Online (AJOL)

    Increased availability of Human Immunodeficiency Virus (HIV) screening test and more public enlightenment have resulted in more people coming forward to access counseling and testing at the HIV counseling and testing centers in Nigeria. Some of the clients however obtained indeterminate and false positive results ...

  7. Performance of a fast acquisition system for in-beam PET monitoring tested with clinical proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Piliero, M.A., E-mail: piliero@pi.infn.it [Department of Physics, University of Pisa and INFN, sezione di Pisa (Italy); Bisogni, M.G. [Department of Physics, University of Pisa and INFN, sezione di Pisa (Italy); Cerello, P. [INFN, sezione di Torino (Italy); Department of Physics, University of Torino (Italy); Del Guerra, A. [Department of Physics, University of Pisa and INFN, sezione di Pisa (Italy); Fiorina, E. [INFN, sezione di Torino (Italy); Department of Physics, University of Torino (Italy); Liu, B.; Morrocchi, M. [Department of Physics, University of Pisa and INFN, sezione di Pisa (Italy); Pennazio, F. [INFN, sezione di Torino (Italy); Department of Physics, University of Torino (Italy); Pirrone, G. [Department of Physics, University of Pisa and INFN, sezione di Pisa (Italy); Wheadon, R. [INFN, sezione di Torino (Italy)

    2015-12-21

    In this work we present the performance of a fast acquisition system for in-beam PET monitoring during the irradiation of a PMMA phantom with a clinical proton beam. The experimental set-up was based on 4 independent detection modules. Two detection modules were placed at one side of a PMMA phantom and the other two modules were placed at the opposite side of the phantom. One detection module was composed of a Silicon Photon Multiplier produced by AdvanSiD coupled to a single scintillating LYSO crystal. The read-out system was based on the TOFPET ASIC managed by a Xilinx ML605 FPGA Evaluation Board (Virtex 6). The irradiation of the PMMA phantom was performed at the CNAO hadrontherapy facility (Pavia, Italy) with a 95 MeV pulsed proton beam. The pulsed time structure of the proton beam was reconstructed by each detection module. The β{sup +} annihilation peak was successfully measured and the production of β{sup +} isotopes emitters was observed as increasing number of 511 keV events detected during irradiation. Finally, after the irradiation, the half lives of the {sup 11}C and {sup 15}O radioactive isotopes were estimated.

  8. Performance of a fast acquisition system for in-beam PET monitoring tested with clinical proton beams

    Science.gov (United States)

    Piliero, M. A.; Bisogni, M. G.; Cerello, P.; Del Guerra, A.; Fiorina, E.; Liu, B.; Morrocchi, M.; Pennazio, F.; Pirrone, G.; Wheadon, R.

    2015-12-01

    In this work we present the performance of a fast acquisition system for in-beam PET monitoring during the irradiation of a PMMA phantom with a clinical proton beam. The experimental set-up was based on 4 independent detection modules. Two detection modules were placed at one side of a PMMA phantom and the other two modules were placed at the opposite side of the phantom. One detection module was composed of a Silicon Photon Multiplier produced by AdvanSiD coupled to a single scintillating LYSO crystal. The read-out system was based on the TOFPET ASIC managed by a Xilinx ML605 FPGA Evaluation Board (Virtex 6). The irradiation of the PMMA phantom was performed at the CNAO hadrontherapy facility (Pavia, Italy) with a 95 MeV pulsed proton beam. The pulsed time structure of the proton beam was reconstructed by each detection module. The β+ annihilation peak was successfully measured and the production of β+ isotopes emitters was observed as increasing number of 511 keV events detected during irradiation. Finally, after the irradiation, the half lives of the 11C and 15O radioactive isotopes were estimated.

  9. Beam test of a prototype read-out system for precision tracking detectors at LHC

    CERN Document Server

    Millmore, M; Gill, K; Hall, G; Howell, G; Jones, L; Langhans, W A; MacEvoy, B C; Matheson, J; Payne, R; Raymond, M; Stefanini, G; Vasey, F; Vitè, Davide F; Watts, S; Wheadon, R

    1996-01-01

    A prototype of a read-out system developed for high spatial precision tracking detectors at LHC has been tested in a beam at CERN. It is based on a radiation hard CMOS front end chip which includes signal amplification, storage in an analogue delay line and a deconvolution filter. Data were transferred from the front-end chip using an analogue fibre optic link emplouing a novel reflective electro-optic modulator and continuous laser light source remote from the detector. This is the first time such a system has been used in an experimental environment and is the basis of the system proposed for the CMS experiment at LHC.

  10. Estimation of the Influence on the LHC Beam of Parasitic Magnetic Fields Resulting from Magnet Interconnections

    CERN Document Server

    Völlinger, C

    2008-01-01

    The Large Hadron Collider (LHC) is equipped with 1232 main superconducting dipole magnets, 474 superconducting quadrupole magnets and more than 7400 superconducting corrector magnets that are distributed around the eight sectors of the accelerator. Each of the magnets is powered via superconducting power cables, the so-called main busbars for the main magnets and auxiliary busbars for the corrector magnets. Within the main magnets, the field produced by the superconducting busbars is shielded by the magnet's iron yoke. However, in the numerous magnet interconnections, the busbars are magnetically unshielded with respect to the beam pipes and produce parasitic fields that can affect the beam. Extensive analyses have been carried out in the past to assess the field quality of the individual magnets and its influence on the two counter-rotating beams. However, no detailed evaluation of the influence of the parasitic fields of the main and auxiliary busbars and their effect on beam optics had been performed so fa...

  11. First results of the novel photon beam position monitor for undulator beamlines of Elettra

    CERN Document Server

    Galimberti, A; Paolucci, G; Presacco, R; Paolicelli, G; Stefani, G

    2001-01-01

    The latest generation SR sources have severe constraints for the stability of the delivered radiation. The high brightness beamlines using undulator radiation are most sensitive to electron beam oscillations. Therefore, photon beam position monitors for undulator radiation are being built as detectors of beam movement and as references for feedback systems. A significant part of the radiation coming from the upstream and downstream dipoles is superimposed on the undulator radiation. A novel detector, incorporating photoelectron analysers, has been developed at Elettra. It can be tuned to the working energy of the undulator from few eV to some keV, the active elements intercepting the tails of the photon distribution. A prototype has been developed for the vertical photon beam position monitoring, and a complete set of characterisation measurements has been performed down to the lowest photon energies of the undulator peak. A description of the detector and its features are presented along with the commissioni...

  12. Progress in the realization of the PRIMA neutral beam test facility

    Science.gov (United States)

    Toigo, V.; Boilson, D.; Bonicelli, T.; Piovan, R.; Hanada, M.; Chakraborty, A.; Agarici, G.; Antoni, V.; Baruah, U.; Bigi, M.; Chitarin, G.; Dal Bello, S.; Decamps, H.; Graceffa, J.; Kashiwagi, M.; Hemsworth, R.; Luchetta, A.; Marcuzzi, D.; Masiello, A.; Paolucci, F.; Pasqualotto, R.; Patel, H.; Pomaro, N.; Rotti, C.; Serianni, G.; Simon, M.; Singh, M.; Singh, N. P.; Svensson, L.; Tobari, H.; Watanabe, K.; Zaccaria, P.; Agostinetti, P.; Agostini, M.; Andreani, R.; Aprile, D.; Bandyopadhyay, M.; Barbisan, M.; Battistella, M.; Bettini, P.; Blatchford, P.; Boldrin, M.; Bonomo, F.; Bragulat, E.; Brombin, M.; Cavenago, M.; Chuilon, B.; Coniglio, A.; Croci, G.; Dalla Palma, M.; D'Arienzo, M.; Dave, R.; De Esch, H. P. L.; De Lorenzi, A.; De Muri, M.; Delogu, R.; Dhola, H.; Fantz, U.; Fellin, F.; Fellin, L.; Ferro, A.; Fiorentin, A.; Fonnesu, N.; Franzen, P.; Fröschle, M.; Gaio, E.; Gambetta, G.; Gomez, G.; Gnesotto, F.; Gorini, G.; Grando, L.; Gupta, V.; Gutierrez, D.; Hanke, S.; Hardie, C.; Heinemann, B.; Kojima, A.; Kraus, W.; Maeshima, T.; Maistrello, A.; Manduchi, G.; Marconato, N.; Mico, G.; Moreno, J. F.; Moresco, M.; Muraro, A.; Muvvala, V.; Nocentini, R.; Ocello, E.; Ochoa, S.; Parmar, D.; Patel, A.; Pavei, M.; Peruzzo, S.; Pilan, N.; Pilard, V.; Recchia, M.; Riedl, R.; Rizzolo, A.; Roopesh, G.; Rostagni, G.; Sandri, S.; Sartori, E.; Sonato, P.; Sottocornola, A.; Spagnolo, S.; Spolaore, M.; Taliercio, C.; Tardocchi, M.; Thakkar, A.; Umeda, N.; Valente, M.; Veltri, P.; Yadav, A.; Yamanaka, H.; Zamengo, A.; Zaniol, B.; Zanotto, L.; Zaupa, M.

    2015-08-01

    The ITER project requires additional heating by two neutral beam injectors, each accelerating to 1 MV a 40 A beam of negative deuterium ions, to deliver to the plasma a power of about 17 MW for one hour. As these requirements have never been experimentally met, it was recognized as necessary to setup a test facility, PRIMA (Padova Research on ITER Megavolt Accelerator), in Italy, including a full-size negative ion source, SPIDER, and a prototype of the whole ITER injector, MITICA, aiming to develop the heating injectors to be installed in ITER. This realization is made with the main contribution of the European Union, through the Joint Undertaking for ITER (F4E), the ITER Organization and Consorzio RFX which hosts the Test Facility. The Japanese and the Indian ITER Domestic Agencies (JADA and INDA) participate in the PRIMA enterprise; European laboratories, such as IPP-Garching, KIT-Karlsruhe, CCFE-Culham, CEA-Cadarache and others are also cooperating. Presently, the assembly of SPIDER is on-going and the MITICA design is being completed. The paper gives a general overview of the test facility and of the status of development of the MITICA and SPIDER main components at this important stage of the overall development; then it focuses on the latest and most critical issues, regarding both physics and technology, describing the identified solutions.

  13. Wake-field and space charge effects on high brightness beams calculations and measured results for the laser driven photoelectrons at BNL-ATF

    Energy Technology Data Exchange (ETDEWEB)

    Parsa, Z.

    1993-05-01

    We discuss the formalism used to study the effects of the interactions between the highly charged particles and the fields in the accelerating structure, including space charge and wake fields. Some of our calculations and numerical simulation results obtained for the Brookhaven National Laboratory (BNL) high-brightness photoelectron beam at the Accelerator Test Facility (ATF) and the measured data at ATF are also included.

  14. Accelerated partial breast irradiation with external beam radiotherapy. First results of the German phase 2 trial

    Energy Technology Data Exchange (ETDEWEB)

    Ott, Oliver J.; Strnad, Vratislav; Stillkrieg, Wilhelm; Fietkau, Rainer [University Hospital Erlangen, Department of Radiation Oncology, Erlangen (Germany); Uter, Wolfgang [University Erlangen-Nuremberg, Dept. of Medical Informatics, Biometry and Epidemiology, Erlangen (Germany); Beckmann, Matthias W. [University Hospital Erlangen, Dept. of Gynecology, Erlangen (Germany)

    2017-01-15

    To evaluate the feasibility and efficacy of external beam three-dimensional (3D) conformal accelerated partial breast irradiation (APBI) for selected patients with early breast cancer. Between 2011 and 2016, 72 patients were recruited for this prospective phase 2 trial. Patients were eligible for APBI if they had histologically confirmed breast cancer or pure ductal carcinoma in situ (DCIS), a tumor diameter ≤3 cm, clear resection margins ≥2 mm, no axillary lymph node involvement, no distant metastases, tumor bed clips, and were aged ≥50 years. Patients were excluded if mammography showed a multicentric invasive growth pattern, or if they had residual diffuse microcalcifications postoperatively, an extensive intraductal component, or vessel invasion. Patients received 3D conformal external beam APBI with a total dose of 38 Gy in 10 fractions in 1-2 weeks. The trial had been registered at the German Clinical Trials Register, DRKS-ID: DRKS00004417. Median follow-up was 25.5 months (range 1-61 months). Local control was maintained in 71 of 72 patients. The 3-year local recurrence rate was 2.1% (95% confidence interval, CI: 0-6.1%). Early toxicity (grade 1 radiodermatitis) was seen in 34.7% (25/72). Late side effects ≥ grade 3 did not occur. Cosmetic results were rated as excellent/good in 96.7% (59/61). APBI with external beam radiotherapy techniques is feasible with low toxicity and, according to the results of the present and other studies, on the way to becoming a standard treatment option for a selected subgroup of patients. (orig.) [German] Untersuchung der Vertraeglichkeit und Sicherheit der externen, 3-D-konformalen akzelerierten Teilbrustbestrahlung (APBI) fuer ausgewaehlte Patientinnen mit einem fruehen Mammakarzinom. Von 2011 bis 2016 wurden 72 Patientinnen in diese prospektive Phase-2-Studie eingebracht. Einschlusskriterien waren ein histologisch gesichertes Mammakarzinom oder DCIS, ein Tumordurchmesser ≤ 3 cm, tumorfreie Resektionsraender ≥ 2

  15. First Test Results of the 150 mm Aperture IR Quadrupole Models for the High Luminosity LHC

    CERN Document Server

    Ambrosio, G; Wanderer, P; Ferracin, P; Sabbi, G

    2017-01-01

    The High Luminosity upgrade of the LHC at CERN will use large aperture (150 mm) quadrupole magnets to focus the beams at the interaction points. The high field in the coils requires Nb3Sn superconductor technology, which has been brought to maturity by the LHC Accelerator Re-search Program (LARP) over the last 10 years. The key design targets for the new IR quadrupoles were established in 2012, and fabrication of model magnets started in 2014. This paper discusses the results from the first single short coil test and from the first short quadrupole model test. Remaining challenges and plans to address them are also presented and discussed.

  16. First Test Results of the 150 mm Aperture IR Quadrupole Models for the High Luminosity LHC

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosio, G. [Fermilab; Chlachidze, G. [Fermilab; Wanderer, P. [Brookhaven; Ferracin, P. [CERN; Sabbi, G. [LBNL, Berkeley

    2016-10-06

    The High Luminosity upgrade of the LHC at CERN will use large aperture (150 mm) quadrupole magnets to focus the beams at the interaction points. The high field in the coils requires Nb3Sn superconductor technology, which has been brought to maturity by the LHC Accelerator Re-search Program (LARP) over the last 10 years. The key design targets for the new IR quadrupoles were established in 2012, and fabrication of model magnets started in 2014. This paper discusses the results from the first single short coil test and from the first short quadrupole model test. Remaining challenges and plans to address them are also presented and discussed.

  17. Comparison of Multi-Test device skin testing and modified RAST results.

    Science.gov (United States)

    Levine, J L; Mabry, R L; Mabry, C S

    1998-06-01

    The initial purpose of this study was to determine the potential correlation between allergy test results obtained with the Multi-Test skin testing method and the radioallergosorbent test (RAST) blood test (used as a "standard"). Twenty patients with a history and physical examination findings suggestive of inhalant allergy underwent both a Multi-Test system screen (14 antigens plus histamine and glycerine controls) and RAST testing. The relationship between wheal size and Multi-Test system grade for each antigen and the corresponding RAST class was studied. The correlation between positive Multi-Test system and RAST results was poor, with an average agreement by antigen of 56.26% and overall agreement of 67.86%. However, the overall agreement between negative Multi-Test system results (RAST results (Test system result indicates that significant inhalant allergy is unlikely, whereas a positive Multi-Test system result necessitates follow-up with more definitive testing by additional skin testing or RAST.

  18. Double Cantilever Beam and End Notched Flexure Fracture Toughness Testing of Two Composite Materials

    Science.gov (United States)

    Kessler, Jeff A.; Adams, Donald F.

    1993-01-01

    Two different unidirectional composite materials were provided by NASA Langley Research Center and tested by the Composite Materials Research Group within the Department of Mechanical Engineering at the University of Wyoming. Double cantilever beam and end notched flexure tests were performed to measure the mode I (crack opening) and mode II (sliding or shear) interlaminar fracture toughness of the two materials. The two composites consisted of IM7 carbon fiber combined with either RP46 resin toughened with special formulation of LaRC IA resin, known as JJS1356; or PES chain extended thermoplastic resin known as JJS1361. Double Cantilever Beam Specimen Configuration and Test Methods As received from NASA, the test specimens were nominally 0.5 inch wide, 6 inches long, and 0.2 inch thick. A 1 inch long Kapton insert at the midplane of one end of the specimen (placed during laminate fabrication) facilitated crack initiation and extension. It was noted that the specimens provided were smaller than the nominal 1.5 inch wide, 9.0 inch long configuration specified. Similarly, the Kapton inserts were of greater length than those in the present specimens. Hence, the data below should not be compared directly to those generated with the referenced methods. No preconditioning was performed on the specimens prior to testing. In general, the methodology was used for the present work. Crack opening loads were introduced to the specimens via piano hinges attached to the main specimen faces at a single end of each specimen. Hinges were bolted to the specimens using the technique presented. The cracks were extended a small distance from the end of the Kapton insert prior to testing. Just before precracking, the sides of the specimens were coated with water-soluble typewriter correction fluid to aid in crack visualization. Scribe marks were then made in the coating at half-inch intervals.

  19. Integrating supervision, control and data acquisition—The ITER Neutral Beam Test Facility experience

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A., E-mail: adriano.luchetta@igi.cnr.it; Manduchi, G.; Taliercio, C.; Breda, M.; Capobianco, R.; Molon, F.; Moressa, M.; Simionato, P.; Zampiva, E.

    2016-11-15

    Highlights: • The paper describes the experience gained in the integration of different systems for the control and data acquisition system of the ITER Neutral Beam Test Facility. • It describes the way the different frameworks have been integrated. • It reports some lessons learnt during system integration. • It reports some authors’ considerations about the development the ITER CODAC. - Abstract: The ITER Neutral Beam (NBI) Test Facility, under construction in Padova, Italy consists in the ITER full scale ion source for the heating neutral beam injector, referred to as SPIDER, and the full size prototype injector, referred to as MITICA. The Control and Data Acquisition System (CODAS) for SPIDER has been developed and is going to be in operation in 2016. The system is composed of four main components: Supervision, Slow Control, Fast Control and Data Acquisition. These components interact with each other to carry out the system operation and, since they represent a common pattern in fusion experiments, software frameworks have been used for each (set of) component. In order to reuse as far as possible the architecture developed for SPIDER, it is important to clearly define the boundaries and the interfaces among the system components so that the implementation of any component can be replaced without affecting the overall architecture. This work reports the experience gained in the development of SPIDER components, highlighting the importance in the definition of generic interfaces among component, showing how the specific solutions have been adapted to such interfaces and suggesting possible approaches for the development of other ITER subsystems.

  20. Standardized Test Results: An Opportunity for English Program Improvement

    Science.gov (United States)

    Jiménez, Maureyra; Rodríguez, Caroll; Rey Paba, Lourdes

    2017-01-01

    This case study explores the relationship between the results obtained by a group of Industrial Engineering students on a national standardized English test and the impact these results had on language program improvement. The instruments used were interviews, document analysis, observations, surveys, and test results analysis. Findings indicate…

  1. Design of a synchrotron radiation detector for the test beam lines at the Superconducting Super Collider Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, R.D.

    1994-01-01

    As part of the particle- and momentum-tagging instrumentation required for the test beam lines of the Superconducting Super Collider (SSC), the synchrotron radiation detector (SRD) was designed to provide electron tagging at momentum above 75 GeV. In a parallel effort to the three test beam lines at the SSC, schedule demands required testing and calibration operations to be initiated at Fermilab. Synchrotron radiation detectors also were to be installed in the NM and MW beam lines at Femilab before the test beam lines at the SSC would become operational. The SRD is the last instrument in a series of three used in the SSC test beam fines. It follows a 20-m drift section of beam tube downstream of the last silicon strip detector. A bending dipole just in of the last silicon strip detector produces the synchrotron radiation that is detected in a 50-mm-square cross section NaI crystal. A secondary scintillator made of Bicron BC-400 plastic is used to discriminate whether it is synchrotron radiation or a stray particle that causes the triggering of the NaI crystal`s photo multiplier tube (PMT).

  2. MMW/IR beam combiner with graphene IR window for MMW/IR compact range compound test

    Science.gov (United States)

    Chen, Dong; Li, Yanhong; Pang, Xudong; Zhu, Weihua; Wang, Liquan; Liu, Zhigang; Wang, Tailei; Zhu, Shouzheng

    2017-06-01

    A millimeter wave (MMW)/infrared (IR) beam combiner with a graphene IR window for the MMW/IR compact range (CR) compound test is creatively proposed with comprehensive analysis and simulation. Graphene is used as the IR window material to transfer the IR feed signal behind a perforated MMW CR reflector for it has the unique property of high IR transmissivity and high MMW conductivity. This research shows that graphene IR windows have better IR transmissivity than conducting inductive mesh IR windows when the beam combiner meets the MMW CR test demanding. Graphene IR windows also show a better MMW test bandwidth than dielectric IR windows. Meanwhile, the graphene IR window MMW/IR beam combiner has a circular aperture test zone with which it is sufficient to test a cylindrical unit under test according to the requirement.

  3. The data acquisition system of the SuperB-SVT beam test

    Science.gov (United States)

    Sbarra, C.; Fabbri, L.; Gabrielli, A.; Giorgi, F.; Lusiani, A.; Paoloni, E.; Pellegrini, G.; Semprini-Cesari, N.; Valentinetti, S.; Villa, M.; Zoccoli, A.

    2013-08-01

    Prototypes of a new hybrid pixel detector and a high resistivity detector with short strips, developed by the VIPIX Collaboration and aimed at equipping the layer-0 of the SuperB vertex detector, have been tested in September 2011 with a 120 GeV pion beam at the SPS H6 beam line at CERN. They are placed at the center of a reference telescope consisting of six planes of silicon detector with a double-sided strip readout. Both the telescope and the detectors under test (DUT) are equipped with a custom-design, data-push digital readout. The main elements of the trigger and data acquisition system are two VME boards (EDRO) organized in a master-slave configuration and responsible for programming the front-end chips of both the telescope and the DUT. The master board distributes a global synchronization clock and the triggers to all devices, including two 3×3 analog-maps matrices placed behind the DUT and supplied with an independent readout. Both EDROs act as event-fragment builders. These are sent out to a remote PC for event building, buffering and storage.

  4. Test-beam measurements and simulation studies of thin pixel sensors for the CLIC vertex detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00574329; Dannheim, Dominik

    The multi-$TeV$ $e^{+}e^{-}$ Compact Linear Collider (CLIC) is one of the options for a future high-energy collider for the post-LHC era. It would allow for searches of new physics and simultaneously offer the possibility for precision measurements of standard model processes. The physics goals and experimental conditions at CLIC set high precision requirements on the vertex detector made of pixel detectors: a high pointing resolution of 3 $\\mu m$, very low mass of 0.2% $X_{0}$ per layer, 10 ns time stamping capability and low power dissipation of 50 mW/$cm^{2}$ compatible with air-flow cooling. In this thesis, hybrid assemblies with thin active-edge planar sensors are characterised through calibrations, laboratory and test-beam measurements. Prototypes containing 50 $\\mu m$ to 150 $\\mu m$ thin planar silicon sensors bump-bonded to Timepix3 readout ASICs with 55 $\\mu m$ pitch are characterised in test beams at the CERN SPS in view of their detection efficiency and single-point resolution. A digitiser for AllP...

  5. MINERvA neutrino detector response measured with test beam data

    Energy Technology Data Exchange (ETDEWEB)

    Aliaga, L. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Altinok, O. [Physics Department, Tufts University, Medford, MA 02155 (United States); Araujo Del Castillo, C. [Sección Física, Departamento de Ciencias, Pontificia Universidad Católica del Perú, Apartado 1761, Lima (Peru); Bagby, L.; Bellantoni, L. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Bergan, W.F. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Bodek, A.; Bradford, R. [University of Rochester, Rochester, New York 14627 (United States); Bravar, A. [University of Geneva, 1211 Geneva 4 (Switzerland); Budd, H. [University of Rochester, Rochester, New York 14627 (United States); Butkevich, A. [Institute for Nuclear Research of the Russian Academy of Sciences, 117312 Moscow (Russian Federation); Martinez Caicedo, D.A. [Centro Brasileiro de Pesquisas Físicas, Rua Dr. Xavier Sigaud 150, Urca, Rio de Janeiro, Rio de Janeiro 22290-180 (Brazil); Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Carneiro, M.F. [Centro Brasileiro de Pesquisas Físicas, Rua Dr. Xavier Sigaud 150, Urca, Rio de Janeiro, Rio de Janeiro 22290-180 (Brazil); Christy, M.E. [Hampton University, Department of Physics, Hampton, VA 23668 (United States); Chvojka, J. [University of Rochester, Rochester, New York 14627 (United States); Motta, H. da [Centro Brasileiro de Pesquisas Físicas, Rua Dr. Xavier Sigaud 150, Urca, Rio de Janeiro, Rio de Janeiro 22290-180 (Brazil); Devan, J. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); and others

    2015-07-21

    The MINERvA collaboration operated a scaled-down replica of thesolid scintillator tracking and sampling calorimeter regions of the MINERvA detector in a hadron test beam at the Fermilab Test Beam Facility. This paper reports measurements with samples of protons, pions, and electrons from 0.35 to 2.0 GeV/c momentum. The calorimetric response to protons, pions, and electrons is obtained from these data. A measurement of the parameter in Birks' law and an estimate of the tracking efficiency are extracted from the proton sample. Overall the data are well described by a Geant4-based Monte Carlo simulation of the detector and particle interactions with agreements better than 4% for the calorimetric response, though some features of the data are not precisely modeled. These measurements are used to tune the MINERvA detector simulation and evaluate systematic uncertainties in support of the MINERvA neutrino cross-section measurement program.

  6. TESTBEAM COORDINATION: 2nd ATLAS H8 Combined Test Beam Workshop

    CERN Document Server

    Di Girolamo, B

    The second ATLAS H8 Combined Test Beam Workshop took place at CERN on 24th and 25th November. After a first workshop in July to warm up the atmosphere, a lot of work has been done in the meantime and there was a clear need to get together again before the end of 2003. The morning of the first day has been devoted to an assessment of the status of the various elements needed for next year’s test beam in H8. Each sub-detector has been presenting the status of preparation, as well as the work in progress and still to be done. The picture has been completed with the first plans for the DAQ from the point of view of the sub-detectors requirements, and a status of the LVL1 elements. Finally, the status and the timescale for availability of the LVL2 and EF infrastructure have been presented. The final draft layout of the sub-detectors has been discussed (figures 1 and 2). A more detailed description of the layout is in preparation to include more information on dead material and on the ancillary detectors (scint...

  7. Beam tests of an integrated prototype of the ATLAS Forward Proton detector

    CERN Document Server

    INSPIRE-00397348

    2016-09-19

    The ATLAS Forward Proton (AFP) detector is intended to measure protons scattered at small angles from the ATLAS interaction point. To this end, a combination of 3D Silicon pixel tracking modules and Quartz-Cherenkov time-of-flight (ToF) detectors is installed 210m away from the interaction point at both sides of ATLAS. Beam tests with an AFP prototype detector combining tracking and timing sub-detectors and a common readout have been performed at the CERN-SPS test-beam facility in November 2014 and September 2015 to complete the system integration and to study the detector performance. The successful tracking-timing integration was demonstrated. Good tracker hit efficiencies above 99.9% at a sensor tilt of 14{\\deg}, as foreseen for AFP, were observed. Spatial resolutions in the short pixel direction with 50 {\\mu}m pitch of 5.5 +/- 0.5 {\\mu}m per pixel plane and of 2.8 +/- 0.5 {\\mu}m for the full four-plane tracker at 14{\\deg} were found, largely surpassing the AFP requirement of 10 {\\mu}m. The timing detector...

  8. TEST RESULTS FOR FUEL-CELL OPERATION ON LANDFILL GAS

    Science.gov (United States)

    Test results from a demonstration of fuel-cell (FC) energy recovery and control of landfill gas emissions are presented. The project addressed two major issues: (i) the design, construction, and testing of a landfill-gas cleanup system; and (ii) a field test of a commercial phos...

  9. Towards powerful negative ion beams at the test facility ELISE for the ITER and DEMO NBI systems

    Science.gov (United States)

    Fantz, U.; Hopf, C.; Wünderlich, D.; Friedl, R.; Fröschle, M.; Heinemann, B.; Kraus, W.; Kurutz, U.; Riedl, R.; Nocentini, R.; Schiesko, L.

    2017-11-01

    The test facility ELISE represents an important step in the European R&D roadmap towards the neutral beam injection (NBI) systems on ITER. ELISE provides early experience with operation of large radio frequency (RF) driven negative hydrogen ion sources. Starting with first plasma pulses in March 2013, ELISE has demonstrated stable 1 h plasma discharges with repetitive 10 s beam extraction pulses every 3 min in hydrogen and deuterium at the pressure of 0.3 Pa required by ITER. Stable ion currents of 9.3 A and 5.8 A have been extracted using only one quarter of the available RF power and reducing the extraction voltage in order to control the co-extracted electrons. The best hydrogen pulse for the required 1000 s for hydrogen gave an extracted current of 21.4 A and resulted in an accelerated current of 17.9 A, using only 53 kW per driver. Linear scaling towards full RF power (90 kW/driver) predicts that the target value of the negative ion current (H-: 33 A extracted, 23 A accelerated; D-: 28 A extracted and 20 A accelerated) can be achieved or even exceeded. Issues in long pulse operation are the caesium dynamics and the stability of the co-extracted electron current, for which the caesium management and the magnetic field configuration are promising tools for optimisation. Operation at high RF power for long pulses has highest priority for the next experimental campaign. In parallel or in a later stage, ELISE could serve as a test bed for studies on a DEMO NBI system. Examples are concepts concerning RF efficiency, operation with largely reduced caesium consumption or with caesium alternatives, and neutralization of the accelerated ion beam by a laser neutralizer in order to improve efficiency and reliability of NBI systems. Lab scale experiments on these topics are carried out presently in parallel with ELISE operation.

  10. Component-level test of molded freeform optics for LED beam shaping using experimental ray tracing

    Science.gov (United States)

    Gutierrez, Gustavo; Hilbig, David; Fleischmann, Friedrich; Henning, Thomas

    2017-06-01

    Due to the high demand of LED light sources, the need to modify their radiation pattern to meet specific application requirements has also increased. This is mostly achieved by using molded secondary optics, which are composed of a combination of several aspherical and freeform surfaces. Unfortunately, the manufacturers of these secondary optics only provide output information at system level, making impossible to independently characterize the secondary optic in order to determine the sources of erroneous results. For this reason, it is necessary to perform a component-level verification leading to the validation of the correctness of the produced secondary optic independently of the light source. To understand why traditional inspection methods fail, it is necessary to take into account that not only errors due to irregularities on the lens surface like pores, glass indentations or scratches affect the performance of the lens, but also differences in refractive index appear after the compression during fabrication process. These internal alterations are generally produced during the cooling stage and their effect over the performance of the lens are not possible to be measured using tactile techniques. Additionally, the small size of the lens and the freeform characteristics of its surface introduce additional difficulties to perform its validation. In this work, the component-level test is done by obtaining the ray mapping function (RMF) which describes the deflection of the light beam as a function of the input angle. To obtain the RMF, firstly a collimated light source is held fix and the lens is rotated. Thus, a virtual point source is created and subsequently by using experimental ray tracing it is possible to determine the ray slopes, which are used to the retrieve the RMF. Under the assumption that the optical system under analysis is lossless and considering the principle of energy conservation, it is possible under specific conditions to use this new

  11. Causes of false-positive HIV rapid diagnostic test results

    OpenAIRE

    Klarkowski, Derryck; O?Brien, Daniel P.; Shanks, Leslie; Singh, Kasha P.

    2014-01-01

    HIV rapid diagnostic tests have enabled widespread implementation of HIV programs in resource-limited settings. If the tests used in the diagnostic algorithm are susceptible to the same cause for false positivity, a false-positive diagnosis may result in devastating consequences. In resource-limited settings, the lack of routine confirmatory testing, compounded by incorrect interpretation of weak positive test lines and use of tie-breaker algorithms, can leave a false-positive diagnosis undet...

  12. Hawaiian Electric Advanced Inverter Test Plan - Result Summary

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Nelson, Austin; Prabakar, Kumaraguru; Nagarajan, Adarsh

    2016-10-14

    This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

  13. The data-acquisition system for the CMS tracker beam tests

    CERN Document Server

    Drouhin, F; Pallarès, A; Verdini, P G; Fontaine, J C; Jeanneau, F; Huss, D

    2000-01-01

    This paper describes the conception and the development of a real- time data-acquisition system for prototype detectors of the Tracker being designed for the compact muon solenoid (CMS) experiment at the Large Hadron Collider of CERN, European Laboratory for Particle Physics, Geneva, Switzerland. The rationale for the development of a dedicated data-acquisition system was the need to perform two fundamental beam tests (the "Milestone Barrel 1" and "Milestone Forward 1"), with large-scale prototypes of the detectors planned as the baseline design. The number of readout channels, the complexity of the readout electronics, and the stringent requirements of the milestone tests mandated that a thorough understanding of the issues related to the physics of the detectors themselves be coupled with the application of leading-edge electronic and software engineering technologies. The implementation described in this paper is based on a distributed architecture. An event builder CPU handles the two main tasks of synchr...

  14. Test Beam Studies for the ATLAS Tile Calorimeter Upgrade Readout Electronics

    CERN Document Server

    Schaefer, Douglas; The ATLAS collaboration

    2018-01-01

    The High Luminosity Large Hadron Collider is expected to deliver 3-4/ab of p-p collisions with around 200 collisions per proton bunch crossing starting in 2026, and the readout electronics of the ATLAS Tile Calorimeter need to be upgraded to deal with the high rate of data taking as well as the large pileup conditions. The proposed digitizer/shaper cards were tested in 2016-7 in the North Area at CERN using the beam from the SPS to produce high energy pions, electrons, muons, and kaons. This presentation summarizes the setup for particle identification and study of the ATLAS Tile Calorimeter data taking in preparation for the production of main boards and digitizer/shaper boards for the photo-multiplier tubes. The fully assembled and tested mini-drawers will start to be installed after the LHC long shutdown in December 2023. The pulse shape, uniformity, and timing precision of the upgrade system are demonstrated.

  15. The performance of the LHCb Pixel Hybrid Photon Detectors in a 25ns structured test-beam

    CERN Document Server

    Perego, Davide Luigi

    2007-01-01

    Particle identification plays an important role in the challenging physics programme of the LHCb experiment. Pion-kaon separation in the wide momentum range 1-100 GeV/$c$ will be achieved by a pair of Ring Imaging Cherenkov detectors, using three radiators. Cherenkov photons in the wavelength range 200-600 nm will be detected by pixel Hybrid Photon Detectors (HPDs) developed by LHCb in collaboration with industry. The HPDs and associated electronics have been designed to operate at 40 MHz, the bunch-crossing frequency of the LHC. Final production photon detectors and the full readout chain, coupled for the LHCb data handling system, have been tested for the first time in a particle beam, operating with the nominal 25 ns bunch spacing, in September 2006. A total of 48 HPDs mounted on three RICH columns have been installed inside a customised RICH detector using N$_2$ GeV/$c$ pion beam at the CERN Super Proton Synchrotron. The results of the tests demonstrate that the HPD is a reliable photon detector that meet...

  16. Analysis of pixel systematics and space point reconstruction with DEPFET PXD5 matrices using high energy beam test data

    Energy Technology Data Exchange (ETDEWEB)

    Reuen, Lars

    2011-02-15

    To answer the current questions in particle physics vertex-detectors, the innermost sub-detector system of a multipurpose particle detector, with brilliant spatial resolution and at the same time with as little sensor material as possible are mandatory. These requirements are the driving force behind the newest generation of silicon pixel sensors like the DEPFET pixel, which incorporates the first amplification stage in form of a transistor in the fully depleted sensor bulk, allowing for a high spatial resolution even with thinned down sensors. A DEPFET pixel prototype system, build for the future TeV-scale liner collider ILC, was characterized in a high energy beam test at CERN with a spatial resolution and statistics that allowed for the first time in-pixel homogeneity measurements of DEPFET pixels. Yet, in the quest for higher precision the sensor development must be accompanied by progress in position reconstruction algorithms. A study with three novel approaches in position reconstruction was undertaken. The results of the in-pixel beam test and the performance of the new methods with an emphasis on {delta}-electrons will be presented here. (orig.)

  17. Test and Simulation Results for Quenches Induced by Fast Losses on a LHC Quadrupole

    CERN Document Server

    Bracco, Ch; Bartmann, W; Bednarek, M; Lechner, A; Sapinski, M; Vittal Shetty, N; Schmidt, R; Solfaroli Camillocci, M; Verweij, A

    2014-01-01

    A test program for beam induced quenches was started in the LHC in 2011 in order to reduce as much as possible BLM-triggered beam dumps, without jeopardising the safety of the superconducting magnets. A first measurement was performed to asses the quench level of a quadrupole located in the LHC injection region in case of fast (ns) losses. It consisted in dumping single bunches onto an injection protection collimator located right upstream of the quadrupole, varying the bunch intensity up to 3×1010 protons and ramping the quadrupole current up to 2200 A. No quench was recorded at that time. The test was repeated in 2013 with increased bunch intensity (6.5×1010 protons); a quench occurred when powering the magnet at 2500 A. The comparison between measurements during beam induced and quench heaters induced quenches is shown. Results of FLUKA simulations on energy deposition, calculations on quench behaviour using the QP3 code and the respective estimates of quench levels are also presented.

  18. Revised data taking schedule with ion beams

    CERN Document Server

    Gazdzicki, Marek; Aduszkiewicz, A; Andrieu, B; Anticic, T; Antoniou, N; Argyriades, J; Asryan, A G; Baatar, B; Blondel, A; Blumer, J; Boldizsar, L; Bravar, A; Brzychczyk, J; Bubak, A; Bunyatov, S A; Choi, K U; Christakoglou, P; Chung, P; Cleymans, J; Derkach, D A; Diakonos, F; Dominik, W; Dumarchez, J; Engel, R; Ereditato, A; Feofilov, G A; Fodor, Z; Ferrero, A; Gazdzicki, M; Golubeva, M; Grebieszkow, K; Grzeszczuk, A; Guber, F; Hasegawa, T; Haungs, A; Igolkin, S; Ivanov, A S; Ivashkin, A; Kadija, K; Katrynska, N; Kielczewska, D; Kikola, D; Kisiel, J; Kobayashi, T; Kolesnikov, V I; Kolev, D; Kolevatov, R S; Kondratiev, V P; Kowalski, S; Kurepin, A; Lacey, R; Laszlo, A; Lyubushkin, V V; Majka, Z; I Malakhov, A; Marchionni, A; Marcinek, A; Maris, I; Matveev, V; Melkumov, G L; Meregaglia, A; Messina, M; Mijakowski, P; Mitrovski, M; Montaruli, T; Mrówczynski, St; Murphy, S; Nakadaira, T; Naumenko, P A; Nikolic, V; Nishikawa, K; Palczewski, T; Pálla, G; Panagiotou, A D; Peryt, W; Planeta, R; Pluta, J; Popov, B A; Posiadala, M; Przewlocki, P; Rauch, W; Ravonel, M; Renfordt, R; Röhrich, D; Rondio, E; Rossi, B; Roth, M; Rubbia, A; Rybczynski, M; Sadovskii, A; Sakashita, K; Schuster, T; Sekiguchi, T; Seyboth, P; Shibata, M; Sissakian, A N; Skrzypczak, E; Slodkowski, M; Sorin, A S; Staszel, P; Stefanek, G; Stepaniak, J; Strabel, C; Ströbele, H; Susa, T; Szentpétery, I; Szuba, M; Tada, M; Taranenko, A; Tsenov, R; Ulrich, R; Unger, M; Vassiliou, M; Vechernin, V V; Vesztergombi, G; Wlodarczyk, Z; Wojtaszek, A; Zipper, W; CERN. Geneva. SPS and PS Experiments Committee; SPSC

    2009-01-01

    This document presents the revised data taking schedule of NA61 with ion beams. The revision takes into account limitations due to the new LHC schedule as well as final results concerning the physics performance with secondary ion beams. It is proposed to take data with primary Ar and Xe beams in 2012 and 2014, respectively, and to test and use for physics a secondary B beam from primary Pb beam fragmentation in 2010, 2011 and 2013.

  19. Results of a 5-Week Schedule of Modern Total Skin Electron Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Morris, Stephen Lloyd, E-mail: stephen.morris@gstt.nhs.uk [St Johns Institute of Dermatology, Guys and St Thomas Hospital, London (United Kingdom); McGovern, Mark; Bayne, Sally; Wain, Mary; Child, Fiona; Whittaker, Sean [St Johns Institute of Dermatology, Guys and St Thomas Hospital, London (United Kingdom)

    2013-08-01

    Purpose: To report the outcomes of a 5-week schedule of total skin electron beam radiation therapy (TSEB) for mycosis fungoides (MF). Methods: Over 5 years, 41 patients with confirmed MF were treated with a modern TSEB technique delivering 30 Gy in 20 fractions over 5 weeks to the whole skin surface. Data were collected prospectively and entered into the skin tumor unit research database. Skin modified skin weighted assessment tool score data were collected to determine response, duration of response, survival, and toxicity. The outcomes were analyzed according to the patient's stage before TSEB, prognostic factors, and adjuvant treatments. Results: Seventeen patients were stage 1B, 19 were stage IIB, 3 were stage III, and 2 were stage IV. The overall response rate was 95%, with a complete response rate of 51%. Seventy-six percent of patients had relapsed at median follow-up of 18 months. The median time to relapse was 12 months, to systemic therapy was 15 months, and to modified skin weighted assessment tool progression above baseline was 44 months. The complete response rate was 59% in stage IB and 47% in stage IIB patients. The median time to skin relapse was longer in stage IB compared with stage IIB, 18 months versus 9 months. The median time to systemic therapy was longer in stage IB compared with stage IIB, >56 months versus 8 months. The median overall survival was 35 months: >56 months for stage IB, 25 months for stage IIB, 46 months for stage III, and 23.5 months for stage IV. Fifteen patients received adjuvant psoralen + ultraviolet A treatment with no difference seen in the time to relapse. Conclusions: This 5-week schedule of TSEB for MF has a high response rate with comparable duration of response to other regimens. Future studies are needed to find adjuvant and combination treatments to improve the duration of response.

  20. Analyzing the Results of Electronic Tests Using Intelligent Agents

    Directory of Open Access Journals (Sweden)

    Pencho Malinov

    2016-03-01

    Full Text Available This article presents the use of intelligent agents in analyzing the results of electronic tests, based on IMS Question & Test Interoperability (QTI standard. The results of the analysis show the average assessment of the conducted test, sections of the study material and issues of the test that hinders students. The aim is to support the educational process by creating a personal assistant which will be in service to teachers. The assistant will be developed like a multi-agent system of rational agents or such based on BDI (Beliefs, Desires, Intentions architecture.

  1. Commissioning experience and first results from the new SLS beam size monitor

    CERN Document Server

    Schlott, V; Saa Hernandez, A; Streun, A; Andersson, A; Breunlin, J; Milas, N

    2013-01-01

    In the context of the TIARA work package “SLS vertical emittance tuning” (SVET), an extremely small vertical beam size of 3.6 $\\mu$m, corresponding to a vertical emittance of 0.9 pm, was verified using an optical monitor based on imaging of $\\pi$-polarized light. Since the existing beam size monitor reached its limit of resolution, a new monitor beam line was designed and installed at the 08BD bending magnet of the Swiss Light Source (SLS) storage ring. Larger magnification and operation at shorter wavelength provide improved spatial resolution. Reflective optics enables convenient switching between different wavelengths. An optical table is located in a hutch outside the storage ring tunnel to provide access during operation. Movable obstacles in the beam path create interference patterns and thus provide redundancy of model based analysis of the images. In this paper we report on our commissioning experience and provide a comparison of the different measurement methods at different wavelengths.

  2. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  3. Design and microwave test of an ultrawideband input/output structure for sheet beam travelling wave tubes

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Guoxiang; Wang, Jianxun; Liu, Guo; Yang, Liya; Luo, Yong [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054 (China); Wang, Shafei [North Electronic Device Research Institution, P.O. Box 947, Beijing 100141 (China)

    2015-06-15

    Broadband operation is of great importance for the applications of travelling wave tubes such as high-data communication and wideband radar. An input/output (I/O) structure operating with broadband property plays a significant role to achieve these applications. In this paper, a Y-type branch waveguide (YTBW) coupler and its improvements are proposed and utilized to construct an extremely wideband I/O structure to ensure the broadband operation for sheet beam travelling wave tubes (SB-TWTs). Cascaded reflection resonators are utilized to improve the isolation characteristic and transmission efficiency. Furthermore, to minimize the reflectivity of the port connected with the RF circuit, wave-absorbing material (WAM) is loaded in the resonator. Simulation results for the YTBW loaded with WAM predict an excellent performance with a 50.2% relative bandwidth for port reflectivity under −15 dB, transmission up to −1.5 dB, and meanwhile isolation under −20 dB. In addition, the coupler has a relatively compact configuration and the beam tunnel can be widened, which is beneficial for the propagation of the electrons. A Q-band YTBW loaded with two reflection resonators is fabricated and microwave tested. Vector network analyzer (VNA) measured results have an excellent agreement with our simulation, which verify our theoretical analysis and simulation calculation.

  4. Design and microwave test of an ultrawideband input/output structure for sheet beam travelling wave tubes

    Science.gov (United States)

    Shu, Guoxiang; Wang, Jianxun; Liu, Guo; Yang, Liya; Luo, Yong; Wang, Shafei

    2015-06-01

    Broadband operation is of great importance for the applications of travelling wave tubes such as high-data communication and wideband radar. An input/output (I/O) structure operating with broadband property plays a significant role to achieve these applications. In this paper, a Y-type branch waveguide (YTBW) coupler and its improvements are proposed and utilized to construct an extremely wideband I/O structure to ensure the broadband operation for sheet beam travelling wave tubes (SB-TWTs). Cascaded reflection resonators are utilized to improve the isolation characteristic and transmission efficiency. Furthermore, to minimize the reflectivity of the port connected with the RF circuit, wave-absorbing material (WAM) is loaded in the resonator. Simulation results for the YTBW loaded with WAM predict an excellent performance with a 50.2% relative bandwidth for port reflectivity under -15 dB, transmission up to -1.5 dB, and meanwhile isolation under -20 dB. In addition, the coupler has a relatively compact configuration and the beam tunnel can be widened, which is beneficial for the propagation of the electrons. A Q-band YTBW loaded with two reflection resonators is fabricated and microwave tested. Vector network analyzer (VNA) measured results have an excellent agreement with our simulation, which verify our theoretical analysis and simulation calculation.

  5. Colorectal Tumour Microsatellite Instability Test Results: Perspectives from Patients

    Directory of Open Access Journals (Sweden)

    Lindor Noralane M

    2004-05-01

    Full Text Available Abstract Purpose To determine which individuals with colorectal cancer (CRC were interested in knowing the results of their tumour microsatellite instability (MSI and immunohistochemistry (IHC testing. We were also interested in the patients' reasons for choosing to learn their results and in the impact of those results on overall self-assessed quality of life. Patients and Methods CRCs from 414 individuals were assayed for MSI and IHC for DNA mismatch repair gene products (MLH1, MSH2, MSH6. Individuals were invited to learn their MSI/IHC results. They randomly received either brief or extended educational materials about the testing and a pretest survey to learn reasons for their interest and to assess their pretest quality of life. Results Of the 414 individuals, 307 (74% chose to learn their results. There was no significant difference in interest in knowing test results according to gender, age, educational level, or family history of colon cancer. The level of detail in the information piece received by the patients did not influence their desire to know their test results. Self-assessed quality of life was not altered by receiving results and was not correlated with the test outcome. Conclusions Individuals with colorectal cancer had a high level of interest in learning their individual MSI/IHC test results and did not seem deterred by the inherent complexity or ambiguity of this information. Regardless of test outcome, results did not significantly affect self-assessed quality of life. Further studies are needed to assess comprehension of results and behavioural changes resulting from the learning of MSI/IHC results.

  6. Results of recent KROTOS FCI tests. Alumina vs. corium melts

    Energy Technology Data Exchange (ETDEWEB)

    Huhtiniemi, I.; Magallon, D.; Hohmann, H. [Commission of the European Communities, Ispra (Italy). Joint Research Center

    1998-01-01

    Recent results from KROTOS fuel-coolant interaction experiments are discussed. Five tests with alumina were performed under highly subcooled conditions, all of these tests resulted in spontaneous steam explosions. Additionally, four tests were performed at low subcooling to confirm, on one hand, the suppression of spontaneous steam explosions under such conditions and, on the other hand, that such a system is still triggerable using an external initiator. The other test parameters in these alumina tests included the melt superheat and the initial pressure. All the tests in the investigated superheat range (150 K - 750 K) produced a steam explosion and no evidence of the explosion suppression by the elevated initial pressure (in the limited range of 0.1 - 0.375 MPa) was observed in the alumina tests. The corium test series include a test with 3 kg of melt under both subcooled and near saturated conditions at ambient pressure. Two additional tests were performed with subcooled water; one test was performed at an elevated pressure of 0.2 MPa with 2.4 kg of melt and another test with 5.1 kg of melt at ambient pressure. None of these tests with corium produced a propagating energetic steam explosion. However, propagating low energy (about twice the energy of the trigger pulse) events were observed. All corium tests produced significantly higher water level swells during the mixing phase than the corresponding alumina tests. Present experimental evidence suggests that the water depletion in the mixing zone suppresses energetic steam explosions with corium melts at ambient pressure and in the present pour geometry. Processes that could produce such a difference in void generation are discussed. (author)

  7. A modern and versatile data-acquisition package for calorimeter prototypes test-beams H4DAQ

    CERN Document Server

    Marini, Andrea Carlo

    2017-01-01

    The upgrade of the calorimeters for the HL-LHC or for future colliders requires an extensive programme of tests to qualify different detector prototypes with dedicated test beams. A common data-acquisition system (called H4DAQ) was developed for the H4 test beam line at the North Area of the CERN SPS in 2014 and it has since been adopted by an increasing number of teams involved in the CMS experiment and AIDA groups. Several different calorimeter prototypes and precision timing detectors have used H4DAQ from 2014 to 2017, and it has proved to be a versatile application, portable to many other beam test environments (the CERN beam lines EA-T9 at the PS, H2 and H4 at the SPS, and at the INFN Frascati Beam Test Facility).The H4DAQ is fast, simple, modular and can be configured to support different setups. The different functionalities of the DAQ core software are split into three configurable finite state machines the data readout, run control, and event builder. The distribution of information and data betw...

  8. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  9. Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Yang, B.; Lee, S.; Westferro, F.; Jaski, Y.; Lenkszus, F.; Sereno, N.; Ramanathan, M.

    2017-03-25

    The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beam intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.

  10. Lamb waves beam deviation due to small inclination of the test structure in air-coupled ultrasonic NDT.

    Science.gov (United States)

    Kichou, H B; Chavez, J A; Turo, A; Salazar, J; Garcia-Hernandez, M J

    2006-12-22

    In Lamb waves inspection, an air-coupled transmitter transducer is oriented at a specific angle such that it generates a pure Lamb mode which propagates along the structure and interacts with any existing defects. For this inspection system, amplitude losses appears when small inclinations of the tested structure occurs. An important factor which affects directly these losses has been observed, it consists of the Lamb waves beam (LWB) deviation due to this bad alignment. In this work, a simple expression of LWB deviation has been deduced. This expression includes the test structure angle, phase velocity of generated Lamb mode, and the phase velocity of waves propagating in the coupled medium. A(0) Lamb mode is generated and detected in 1 mm thick aluminium plate sample using 1 MHz PZ27 piezoelectric transducers of 20 mm of diameter. Experimental LWB deviation angles are measured for different inclination angles of the test sample. A comparative study is released with theoretical results. For 1 degree of misalignment in the aluminium plate inclination, and transducers separation distance of 35 mm, LWB deviation angle is around 7 degrees and the amplitude is reduced by around 11%. Then, for a large separation distance, we must move the receiver transducer to detect the deviated LWB. It is shown that, for both theoretical and experimental studies, the LWB deviation and its measured amplitude are very sensitive to the alignment of the tested structure with respect to the transmitter-receiver transducers plane. In metal plates it is most satisfactory to use A(0) mode compared with S(0) mode since it is easy to excite and has a large amplitude and small deviation beam angles.

  11. In situ radiation test of silicon and diamond detectors operating in superfluid helium and developed for beam loss monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kurfürst, C.; Dehning, B.; Sapinski, M.; Bartosik, M.R.; Eisel, T.; Fabjan, C.; Rementeria, C.A. [CERN, Geneva (Switzerland); Griesmayer, E. [CIVIDEC Instrumentation, GmbH, Vienna (Austria); Eremin, V. [Ioffe Institute, St. Petersburg (Russian Federation); Verbitskaya, E., E-mail: elena.verbitskaya@cern.ch [Ioffe Institute, St. Petersburg (Russian Federation); Zabrodskii, A.; Fadeeva, N.; Tuboltsev, Y.; Eremin, I. [Ioffe Institute, St. Petersburg (Russian Federation); Egorov, N. [Research Institute of Material Science and Technology, Zelenograd, Moscow (Russian Federation); Härkönen, J.; Luukka, P.; Tuominen, E. [Helsinki Institute of Physics, Helsinki (Finland)

    2015-05-11

    As a result of the foreseen increase in the luminosity of the Large Hadron Collider, the discrimination between the collision products and possible magnet quench-provoking beam losses of the primary proton beams is becoming more critical for safe accelerator operation. We report the results of ongoing research efforts targeting the upgrading of the monitoring system by exploiting Beam Loss Monitor detectors based on semiconductors located as close as possible to the superconducting coils of the triplet magnets. In practice, this means that the detectors will have to be immersed in superfluid helium inside the cold mass and operate at 1.9 K. Additionally, the monitoring system is expected to survive 20 years of LHC operation, resulting in an estimated radiation fluence of 1×10{sup 16} proton/cm{sup 2}, which corresponds to a dose of about 2 MGy. In this study, we monitored the signal degradation during the in situ irradiation when silicon and single-crystal diamond detectors were situated in the liquid/superfluid helium and the dependences of the collected charge on fluence and bias voltage were obtained. It is shown that diamond and silicon detectors can operate at 1.9 K after 1×10{sup 16} p/cm{sup 2} irradiation required for application as BLMs, while the rate of the signal degradation was larger in silicon detectors than in the diamond ones. For Si detectors this rate was controlled mainly by the operational mode, being larger at forward bias voltage. - Highlights: • Silicon and diamond detectors are proposed for beam loss monitoring at LHC. • The first in situ radiation test of Si and diamond detectors at 1.9 K is described. • Both diamond and silicon detectors survived after 1×10{sup 16} p/cm{sup 2} irradiation at 1.9 K. • The rate of Si detectors degradation depends on bias polarity and is larger at V{sub forw}. • Sensitivity of Si detectors irradiated to 1×10{sup 16} p/cm{sup 2} is independent on resistivity.

  12. Does empirical Clostridium difficile infection (CDI) therapy result in false-negative CDI diagnostic test results?

    Science.gov (United States)

    Sunkesula, Venkata C K; Kundrapu, Sirisha; Muganda, Christine; Sethi, Ajay K; Donskey, Curtis J

    2013-08-01

    Patients with suspected Clostridium difficile infection (CDI) often receive empirical therapy prior to collection of stool specimens for diagnostic testing. The likelihood that such empirical therapy might result in false-negative CDI test results is unknown. We conducted a prospective study of CDI patients to determine the time to conversion of CDI test results, including polymerase chain reaction (PCR) for toxin B genes, glutamate dehydrogenase, and toxigenic culture, from positive to negative during CDI therapy. We evaluated the frequency of and risk factors for persistence of positive CDI tests. For patients receiving empirical therapy, we assessed the frequency of conversion of positive CDI test results at the time of the test order to negative by the time clinical staff collected stool specimens for testing. For 51 CDI patients, PCR, glutamate dehydrogenase, and toxigenic culture results converted to negative at similar rates. For PCR, 14%, 35%, and 45% of positive CDI tests converted to negative after 1, 2, and 3 days of treatment, respectively. Increased age and infection with North American pulsed-field gel electrophoresis strains were associated with persistent positive PCR results. For CDI patients diagnosed at the time of the test order, conversion to negative PCR results by the time clinical stool specimens were collected occurred in 4 of 9 (44%) patients who were prescribed empirical CDI therapy versus 0 of 23 (0%) who were not (P = .004). Empirical treatment for suspected CDI cases may result in false-negative PCR results if there are delays in stool specimen collection.

  13. Pattern Of Skin Prick Allergy Test Results In Enugu | Mgbor ...

    African Journals Online (AJOL)

    The “Allergo Ganzer” Allergy test kit (Germany) was used for skin prick allergy test on each patient. Result The reactivities to test allergens were found to be in 44.4% patients positive to house dust mites I & II, 27.2% to house dust, 22% to grass, 16.6% to cereal and trees respectively and only 8.3% to mould. Conclusion

  14. Preliminary results on time-resolved ion beam induced luminescence applied to the provenance study of lapis lazuli

    Science.gov (United States)

    Czelusniak, C.; Palla, L.; Massi, M.; Carraresi, L.; Giuntini, L.; Re, A.; Lo Giudice, A.; Pratesi, G.; Mazzinghi, A.; Ruberto, C.; Castelli, L.; Fedi, M. E.; Liccioli, L.; Gueli, A.; Mandò, P. A.; Taccetti, F.

    2016-03-01

    This work will present preliminary results concerning the use of time-resolved ion beam induced luminescence applied to provenance studies of lapis lazuli. Measurements were performed at the pulsed beam facility at LABEC laboratory in Florence. Lapis lazuli is a semi-precious gemstone, used as ornament since the early civilizations that can be found in few places on Earth. The importance of this work lies in understanding the origin of various samples of lapis lazuli, from which it may be possible to gain insight into trade routes from ancient times. The samples studied in this work originated from Chile, Afghanistan, Tajikistan, Myanmar, and Siberia. The stones were irradiated with 3 MeV protons and the resulting luminescence was detected by a photomultiplier tube, whose output was acquired using a sampling digitizer VME module (CAEN/V1720). Wavelength discrimination was performed at 430 nm utilizing a range of beam currents. The results showed that, by changing the beam current intensity, one can study different features of lapis lazuli, and this may aid in distinguishing lapis lazuli from different provenances.

  15. Preliminary results on time-resolved ion beam induced luminescence applied to the provenance study of lapis lazuli

    Energy Technology Data Exchange (ETDEWEB)

    Czelusniak, C. [Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); Palla, L. [Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa and Università di Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Massi, M. [Dipartimento di Fisica e Astronomia, Università di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); Carraresi, L.; Giuntini, L. [Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); Re, A.; Lo Giudice, A. [Dipartimento di Fisica, Università di Torino & INFN Sezione di Torino, Via Giuria 1, 10125 Torino (Italy); Pratesi, G. [Museo di Storia Naturale, Università di Firenze, Via G. La Pira 4, 50121 Firenze (Italy); Mazzinghi, A. [Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); Ruberto, C. [Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); Dipartimento di Chimica, Università di Firenze, Via della Lastruccia 1, 50019 Sesto Fiorentino, Firenze (Italy); Castelli, L. [Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Firenze, Via Sansone 1, I-50019 Sesto Fiorentino, Firenze (Italy); and others

    2016-03-15

    This work will present preliminary results concerning the use of time-resolved ion beam induced luminescence applied to provenance studies of lapis lazuli. Measurements were performed at the pulsed beam facility at LABEC laboratory in Florence. Lapis lazuli is a semi-precious gemstone, used as ornament since the early civilizations that can be found in few places on Earth. The importance of this work lies in understanding the origin of various samples of lapis lazuli, from which it may be possible to gain insight into trade routes from ancient times. The samples studied in this work originated from Chile, Afghanistan, Tajikistan, Myanmar, and Siberia. The stones were irradiated with 3 MeV protons and the resulting luminescence was detected by a photomultiplier tube, whose output was acquired using a sampling digitizer VME module (CAEN/V1720). Wavelength discrimination was performed at 430 nm utilizing a range of beam currents. The results showed that, by changing the beam current intensity, one can study different features of lapis lazuli, and this may aid in distinguishing lapis lazuli from different provenances.

  16. Beam instability induced by rf deflectors in the combiner ring of the CLIC test facility and mitigation by damped deflecting structures

    CERN Document Server

    Alesini, D; Biscari, C; Ghigo, A; Corsini, R

    2011-01-01

    In the CTF3 (CLIC test facility 3) run of November 2007, a vertical beam instability has been found in the combiner ring during operation. After a careful analysis, the source of the instability has been identified in the vertical deflecting modes trapped in the rf deflectors and excited by the beam passage. A dedicated tracking code that includes the induced transverse wakefield and the multibunch multipassage effects has been written and the results of the beam dynamics analysis are presented in the paper. The mechanism of the instability was similar to the beam breakup in a linear accelerator or in an energy recovery linac. The results of the code allowed identifying the main key parameters driving such instability and allowed finding the main knobs to mitigate it. To completely suppress such beam instability, two new rf deflectors have been designed, constructed, and installed in the ring. In the new structures the frequency separation between the vertical and horizontal deflecting modes has been increase...

  17. Test beam analysis of ultra-thin hybrid pixel detector assemblies with Timepix readout ASICs

    CERN Document Server

    Alipour Tehrani, Niloufar; Dannheim, Dominik; Firu, Elena; Kulis, Szymon; Redford, Sophie; Sicking, Eva

    2016-01-01

    The requirements for the vertex detector at the proposed Compact Linear Collider imply a very small material budget: less than 0.2% of a radiation length per detection layer including services and mechanical supports. We present here a study using Timepix readout ASICs hybridised to pixel sensors of 50 − 500 μm thickness, including assemblies with 100 μm thick sensors bonded to thinned 100μm thick ASICs. Sensors from three producers (Advacam, Micron Semiconductor Ltd, Canberra) with different edge termination technologies (active edge, slim edge) were bonded to Timepix ASICs. These devices were characterised with the EUDET telescope at the DESY II test beam using 5.6 GeV electrons. Their performance for the detection and tracking of minimum ionising particles was evaluated in terms of charge sharing, detection efficiency, single-point resolution and energy deposition.

  18. Beam test of a 12-layer scintillating-fiber charged-particle tracking system

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, B.; Howell, B.L.; Koltick, D.; McIlwain, R.L.; Schmitz, C.J.; Shibata, E.I.; Zhou, Z.; Baumbaugh, B.; Ivancic, M.; Jaques, J.; Kehoe, R.; Kelley, M.; Mahoney, M.; Marchant, J.; Ruchti, R.; Wayne, M.; Atac, M.; Baumbaugh, A.; Elias, J.E.; Romero, A.; Chrisman, D.; Park, J.; Adams, M.R.; Chung, M.; Goldberg, H.; Margulies, S.; Solomon, J.; Chaney, R.; Orgeron, J.; Armstrong, T.; Lewis, R.A.; Mitchell, G.S.; Moore, R.S.; Passaneau, J.; Smith, G.A.; Corcoran, M.; Adams, D.; Bird, F.; Fenker, H.; Regan, T.; Thomas, J. (Dept. of Physics, Purdue Univ., West Lafayette, IN (United States) Dept. of Physics, Univ. of Notre Dame, IN (United States) Fermilab, Batavia, IL (United States) Dept. of Physics, Univ. of California, Los Angeles, CA (United States) Dept. of Physics, Univ. of Illinois, Chicago, IL (United States) Dept. of Physics, Univ. of Texas, Richardson, TX (United States) Dept. of Physics, Pennsylvania State Univ., University Park, PA (United States) Dept. of Physics, Rice Univ

    1994-02-01

    A 96-channel, 3-superlayer, scintillating-fiber tracking system has been tested in a 5 GeV/c [pi][sup -] beam. The scintillating fibers were 830 [mu]m in diameter, spaced 850 [mu]m apart, and 4.3 m in length. They were coupled to 6 m long, clear fiber waveguides and finally to visible light photon counters. A spatial resolution of [approx]150 [mu]m for a double-layered ribbon was achieved with this tracking system. This first prototype of a charged-particle tracking system configured for the Solenoidal Detector Collaboration at the Superconducting Super Collider is a benchmark in verifying the expected number of photoelectrons from the fibers. (orig.)

  19. A prototype of the CMS Object Oriented Reconstruction and Analysis Framework for the Beam Test Data

    CERN Document Server

    Silvestris, L

    1998-01-01

    CMS software requirements and computing resources will by far exceed those of any existing high energy physics experiment, not only for the complexity of the detector and of the physics task but also for the size of the collaboration and the long time scale. Therefore, software should be developed keeping in mind not only performance but also modularity, flexibility, maintainability, quality assurance and documentation. Object Orientation has been identified as the enabling technology, since it directly addresses this kind of problems. We will report on the development of an Object Oriented Reconstruction and Analysis Framework for the CMS experiment and in particular on a prototype of a complete analysis chain for the CMS test-beam data. The analysis chain consists of three different components: data acquisition, reconstruction and analysis, and interactive analysis tools. In the online part the data, read from the VME, are stored into an Objectivity federated database. Later, using an automatic procedure, t...

  20. Usefulness of Routine Antibacterial Susceptibility Testing Results for ...

    African Journals Online (AJOL)

    The objective was to evaluate the usefulness and reliability of routine antibacterial susceptibility testing data in antibacterial resistance surveillance in Lagos Metropolis. The antibacterial susceptibility testing results of 3,961 clinical isolates of bacteria from four highly rated hospitals in Lagos metropolis were collated and ...

  1. Documenting and Explaining Major Field Test Results among Undergraduate Students

    Science.gov (United States)

    Contreras, Salvador; Badua, Frank; Chen, Jiun Shiu; Adrian, Mitchell

    2011-01-01

    The authors investigated the results of the Educational Testing Service Major Field Test (ETS-MFT) administered to business majors at a U.S. state university. Longitudinal trends and cross-sectional differences are documented, including significant performance differences among students of different majors. Findings suggest that a cohort affect…

  2. Measurement and interpretation of skin prick test results

    NARCIS (Netherlands)

    J.P.M. van der Valk; R. Gerth van Wijk (Roy); E.J. Hoorn (Ewout); L. Groenendijk (Laurens); I.M. Groenendijk (Ilse M.); N.W. de Jong (Nicolette)

    2016-01-01

    textabstractBackground: There are several methods to read skin prick test results in type-I allergy testing. A commonly used method is to characterize the wheal size by its 'average diameter'. A more accurate method is to scan the area of the wheal to calculate the actual size. In both methods, skin

  3. Test results for SEU and SEL immune memory circuits

    Science.gov (United States)

    Wiseman, D.; Canaris, J.; Whitaker, S.; Gambles, J.; Arave, K.; Arave, L.

    1993-01-01

    Test results for three SEU logic/circuit hardened CMOS memory circuits verify upset and latch-up immunity for two configurations to be in excess of 120 MeV cm(exp 2)/mg using a commercial, non-radiation hardened CMOS process. Test chips from three separate fabrication runs in two different process were evaluated.

  4. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  5. Laboratory Test Results for the Travelling Wave Fault Location Scheme

    Directory of Open Access Journals (Sweden)

    Krzysztof Glik

    2014-03-01

    Full Text Available The article describes the travelling wave fault location algorithm for high voltage lines based on wavelet transform. The algorithm is implemented in a prototype and tested in the laboratory. The article presents the hardware and software part of a travelling wave fault locator, methodology and test results.

  6. A Comparison Between The NORCAT Rover Test Results and the ISRU Excavation System Model Predictions Results

    Science.gov (United States)

    Gallo, Christopher A.; Agui, Juan H.; Creager, Colin M.; Oravec, Heather A.

    2012-01-01

    An Excavation System Model has been written to simulate the collection and transportation of regolith on the moon. The calculations in this model include an estimation of the forces on the digging tool as a result of excavation into the regolith. Verification testing has been performed and the forces recorded from this testing were compared to the calculated theoretical data. The Northern Centre for Advanced Technology Inc. rovers were tested at the NASA Glenn Research Center Simulated Lunar Operations facility. This testing was in support of the In-Situ Resource Utilization program Innovative Partnership Program. Testing occurred in soils developed at the Glenn Research Center which are a mixture of different types of sands and whose soil properties have been well characterized. This testing is part of an ongoing correlation of actual field test data to the blade forces calculated by the Excavation System Model. The results from this series of tests compared reasonably with the predicted values from the code.

  7. Development of RFQ particle dynamics simulation tools and validation with beam tests

    Energy Technology Data Exchange (ETDEWEB)

    Maus, Johannes M.

    2010-07-01

    Two different strategies of designing RFQs have been introduced. The analytic description of the electric fields inside the quadrupole channel has been derived and the two term simplification was shown as well as the limitation of these approaches. The main work of this thesis was the implementation and analysis of a multigrid Poisson solver to describe the potential and electric field of RFQs which are needed to simulate the particle dynamics accurately. The main two ingredients of a multigrid Poisson solver are the ability of a Gauss-Seidel iteration method to smooth the error of an approximation within a few iteration steps and the coarse grid principle. The smoothing corresponds to a damping of the high frequency components of the error. After the smoothing, the error term can well be approximated on a coarser grid in which the low frequency components of the error on the fine grid are converted to high frequency errors on the coarse grid which can be damped further with the same Gauss-Seidel method. After implementation, the multigrid Poisson solver was analyzed using two different type of test problems: with and without a charge density. As a charge density, a homogeneously charged ball and cylinder were used to represent the bunched and unbunched beam and placed inside a quadruple channel. The solver showed a good performance. Next, the performance of the solver to calculate the external potentials (and fields) of RFQs was analyzed. Closing the analysis of the external field, the transmission and fraction of accelerated particles of the set of 12 RFQs for the two different methods were shown. In the last chapter of this thesis some experimental work on the MAFF (Munich Accelerator for Fission Fragments) IH-RFQ is described. The MAFF RFQ was designed to accelerate very neutron-rich fission fragments for various experiments. The machine was assembled in Frankfurt and a beam test stand was built. As a part of this thesis the shunt impedance of the structure was

  8. Quench Tests of LHC Magnets with Beam: Studies on Beam Loss development and determination of Quench levels

    CERN Document Server

    Priebe, A; Sapinski, M

    The application of superconducting materials in the field of high energy accelerator physics not only opens the doors to the generation of the magnetic fields unattainable to normal conductors but also demands facing new challenges. A transition fromthe superconducting state, which is characterized by a resistance-free flow of the electric current, to the normal conducting state is called quenching. This process might be extremely dangerous and even lead to destruction of amagnet superconducting coil if no protecting actions are taken. Therefore, the knowledge of a magnet quench level, i.e. amount of energy which causes the transition to the resistive state, is crucial for the safety and operational efficiency of the accelerator. Regarding that, specific thresholds are incorporated to dedicated quench prevention systems in order to suppress the origin of detected energy perturbation, for example beam losses, or mitigate the consequences of the quenching process by dissipating the energy stored in the magnetic...

  9. Power-cooling mismatch test series. Test PCM-2A; test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Cawood, G.W.; Holman, G.W.; Martinson, Z.R.; Legrand, B.L.

    1976-09-01

    The report describes the results of an in-pile experimental investigation of pre- and postcritical heat flux (CHF) behavior of a single 36-inch-long, pressurized water reactor (PWR) type, UO/sub 2/-fueled, zircaloy-clad fuel rod. The nominal coolant conditions for pressure and temperature were representative of those found in a commercial PWR. Nine separate departures from nucleate boiling (DNB) cycles were performed by either of two different methods: (a) decreasing the coolant flow rate while the fuel rod power was held constant, or (b) increasing the fuel rod power while the coolant flow rate was held constant. DNB was obtained during eight of the nine cycles performed. For the final flow reduction, the mass flux was decreased to 6.1 x 10/sup 5/ lb/hr-ft/sup 2/ at a constant peak linear heat generation rate of 17.8 kW/ft. The fuel rod was allowed to remain in film boiling for about 210 seconds during this final flow reduction. The fuel rod remained intact during the test. Results of on-line measurements of the fuel rod behavior are presented together with discussion of instrument performance. A comparison of the data with Fuel Rod Analysis Program-Transient 2 (FRAP-T2) computer code calculations is included.

  10. Pharmacogenetic Allele Nomenclature: International Workgroup Recommendations for Test Result Reporting

    NARCIS (Netherlands)

    L.V. Kalman; J.A.G. Agúndez; M.L. Appell (M Lindqvist); J.L. Black; G.C. Bell; S. Boukouvala; C. Bruckner; E. Bruford (Elspeth); K. Caudle; S.A. Coulthard; A.K. Daly; A.L. Del Tredici; J.T. Den Dunnen; K. Drozda; R.E. Everts; D. Flockhart; R.R. Freimuth; A. Gaedigk; H. Hachad; T. Hartshorne; M. Ingelman-Sundberg (Magnus); T.E. Klein (T.); V.M. Lauschke; D. Maglott (Donna); H.L. McLeod (Howard); G.A. McMillin; U.A. Meyer; D.J. Müller; D.A. Nickerson (Deborah); W.S. Oetting; M. Pacanowski; V.M. Pratt; M.V. Relling (Mary); A. Roberts; D. Flesch-Janys (Dieter); K. Sangkuhl; M. Schwab; S.A. Scott (S.); S.C. Sim; R.K. Thirumaran; L.H. Toji; R.F. Tyndale; R.H.N. van Schaik (Ron); M. Whirl-Carrillo; K.T.J. Yeo; U. Zanger (Ulrich)

    2016-01-01

    textabstractThis article provides nomenclature recommendations developed by an international workgroup to increase transparency and standardization of pharmacogenetic (PGx) result reporting. Presently, sequence variants identified by PGx tests are described using different nomenclature systems. In

  11. Diffraction Radiation test at CesrTA for Non-Intercepting Micron-scale Beam Size Measurement

    CERN Document Server

    Bobb, L; Lefevre, T; Mazzoni, S; Aumeyr, T; Karataev, P; Billing, M; Conway, J

    2013-01-01

    Diffraction radiation (DR) is produced when a relativistic charged particle moves in the vicinity of a medium. The electric field of the charged particle polarises the target atoms which then oscillate, emitting radiation with a very broad spectrum. The spatial-spectral properties of DR are sensitive to a range of electron beam parameters. Furthermore, the energy loss due to DR is so small that the electron beam parameters are unchanged. DR can therefore be used to develop non-invasive diagnostic tools. To achieve the micron-scale resolution required to measure the transverse (vertical) beam size using incoherent DR in CLIC, DR in UV and X-ray spectral-range must be investigated. Experimental validation of such a scheme is ongoing at CesrTA at Cornell University, USA. Here we report on the test using 0.5 mm and 1 mm target apertures on a 2.1 GeV electron beam and 400 nm wavelength.

  12. Preliminary results of steel containment vessel model test

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, T.; Komine, K.; Arai, S. [Nuclear Power Engineering Corp., Tokyo (Japan)] [and others

    1997-04-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11-12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented.

  13. Preliminary results of steel containment vessel model test

    Energy Technology Data Exchange (ETDEWEB)

    Luk, V.K.; Hessheimer, M.F. [Sandia National Labs., Albuquerque, NM (United States); Matsumoto, T.; Komine, K.; Arai, S. [Nuclear Power Engineering Corp., Tokyo (Japan); Costello, J.F. [Nuclear Regulatory Commission, Washington, DC (United States)

    1998-04-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11--12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented.

  14. Linac-integrated 4D cone beam CT: first experimental results

    Science.gov (United States)

    Dietrich, Lars; Jetter, Siri; Tücking, Thomas; Nill, Simeon; Oelfke, Uwe

    2006-06-01

    A new online imaging approach, linac-integrated cone beam CT (CBCT), has been developed over the past few years. It has the advantage that a patient can be examined in their treatment position directly before or during a radiotherapy treatment. Unfortunately, respiratory organ motion, one of the largest intrafractional organ motions, often leads to artefacts in the reconstructed 3D images. One way to take this into account is to register the breathing phase during image acquisition for a phase-correlated image reconstruction. Therefore, the main focus of this work is to present a system which has the potential to investigate the correlation between internal (movement of the diaphragm) and external (data of a respiratory gating system) information about breathing phase and amplitude using an inline CBCT scanner. This also includes a feasibility study about using the acquired information for a respiratory-correlated 4D CBCT reconstruction. First, a moving lung phantom was used to develop and to specify the required methods which are based on an image reconstruction using only projections belonging to a certain moving phase. For that purpose, the corresponding phase has to be detected for each projection. In the case of the phantom, an electrical signal allows one to track the movement in real time. The number of projections available for the image reconstruction depends on the breathing phase and the size of the position range from which projections should be used for the reconstruction. The narrower this range is, the better the inner structures can be located, but also the noise of the images increases due to the limited number of projections. This correlation has also been analysed. In a second step, the methods were clinically applied using data sets of patients with lung tumours. In this case, the breathing phase was detected by an external gating system (AZ-733V, Anzai Medical Co.) based on a pressure sensor attached to the patient's abdominal region with a

  15. Causes of false-positive HIV rapid diagnostic test results.

    Science.gov (United States)

    Klarkowski, Derryck; O'Brien, Daniel P; Shanks, Leslie; Singh, Kasha P

    2014-01-01

    HIV rapid diagnostic tests have enabled widespread implementation of HIV programs in resource-limited settings. If the tests used in the diagnostic algorithm are susceptible to the same cause for false positivity, a false-positive diagnosis may result in devastating consequences. In resource-limited settings, the lack of routine confirmatory testing, compounded by incorrect interpretation of weak positive test lines and use of tie-breaker algorithms, can leave a false-positive diagnosis undetected. We propose that heightened CD5+ and early B-lymphocyte response polyclonal cross-reactivity are a major cause of HIV false positivity in certain settings; thus, test performance may vary significantly in different geographical areas and populations. There is an urgent need for policy makers to recognize that HIV rapid diagnostic tests are screening tests and mandate confirmatory testing before reporting an HIV-positive result. In addition, weak positive results should not be recognized as valid except in the screening of blood donors.

  16. Beam tests of full-size prototypes of silicon detectors for TOF heavy-ions diagnostics in Super-FRS

    Science.gov (United States)

    Eremin, V.; Bezbakh, A.; Eremin, I.; Egorov, N.; Fomichev, A.; Golovkov, M.; Gorshkov, A.; Galkin, A.; Kiselev, O.; Knyazev, A.; Kostyleva, D.; Krupko, S.; Mitina, D.; Slepnev, R.; Sharov, P.; Verbitskaya, E.

    2017-03-01

    The full-size prototypes of large-area silicon detectors for the Time-Of-Flight (TOF) diagnostics of heavy ions were tested with 132Xe (600 MeV/u) beam. The obtained time resolution of the prototypes was about 13 ps, which satisfied the requirements of diagnostics for the Super Fragment Separator (Super-FRS) that is under development at GSI, Darmstadt, Germany. The irradiation effect on the timing properties of silicon detectors was studied with super-fast silicon pad detectors with a rise time of 190 ps. It was shown that the changes in the rise time of the leading edge of the detector current response to 40Ar ions (40.5 MeV/u) were negligible up to the fluence of 2 × 1011 ion/cm2 expected after one year of Super-FRS operation. This result confirms the model of the leading edge current pulse formation via a flow of the polarization current in dense tracks of heavy ions and shows the perspectives for application of silicon detectors for the TOF diagnostics of intensive heavy-ion beams.

  17. Planck 2015 results. VII. High Frequency Instrument data processing: Time-ordered information and beams

    Science.gov (United States)

    Planck Collaboration; Adam, R.; Ade, P. A. R.; Aghanim, N.; Arnaud, M.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Bartolo, N.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bertincourt, B.; Bielewicz, P.; Bock, J. J.; Bonavera, L.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Boulanger, F.; Bucher, M.; Burigana, C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chary, R.-R.; Chiang, H. C.; Christensen, P. R.; Clements, D. L.; Colombi, S.; Colombo, L. P. L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B. P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R. D.; Davis, R. J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Diego, J. M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T. A.; Eriksen, H. K.; Falgarone, E.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A. A.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Ghosh, T.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K. M.; Gratton, S.; Gruppuso, A.; Gudmundsson, J. E.; Hansen, F. K.; Hanson, D.; Harrison, D. L.; Henrot-Versillé, S.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Hornstrup, A.; Hovest, W.; Huffenberger, K. M.; Hurier, G.; Jaffe, A. H.; Jaffe, T. R.; Jones, W. C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T. S.; Kneissl, R.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C. R.; Le Jeune, M.; Leahy, J. P.; Lellouch, E.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P. B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P. M.; Macías-Pérez, J. F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P. G.; Martínez-González, E.; Masi, S.; Matarrese, S.; McGehee, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Moreno, R.; Morgante, G.; Mortlock, D.; Moss, A.; Mottet, S.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C. B.; Nørgaard-Nielsen, H. U.; Noviello, F.; Novikov, D.; Novikov, I.; Oxborrow, C. A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Pearson, T. J.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Pratt, G. W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Reinecke, M.; Remazeilles, M.; Renault, C.; Renzi, A.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sandri, M.; Santos, D.; Sauvé, A.; Savelainen, M.; Savini, G.; Scott, D.; Seiffert, M. D.; Shellard, E. P. S.; Spencer, L. D.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Wade, L. A.; Wandelt, B. D.; Watson, R.; Wehus, I. K.; Yvon, D.; Zacchei, A.; Zonca, A.

    2016-09-01

    The Planck High Frequency Instrument (HFI) has observed the full sky at six frequencies (100, 143, 217, 353, 545, and 857 GHz) in intensity and at four frequencies in linear polarization (100, 143, 217, and 353 GHz). In order to obtain sky maps, the time-ordered information (TOI) containing the detector and pointing samples must be processed and the angular response must be assessed. The full mission TOI is included in the Planck 2015 release. This paper describes the HFI TOI and beam processing for the 2015 release. HFI calibration and map making are described in a companion paper. The main pipeline has been modified since the last release (2013 nominal mission in intensity only), by including a correction for the nonlinearity of the warm readout and by improving the model of the bolometer time response. The beam processing is an essential tool that derives the angular response used in all the Planck science papers and we report an improvement in the effective beam window function uncertainty of more than a factor of 10 relative to the2013 release. Noise correlations introduced by pipeline filtering function are assessed using dedicated simulations. Angular cross-power spectra using data sets that are decorrelated in time are immune to the main systematic effects.

  18. Non-linear beam dynamics tests in the LHC: LHC dynamic aperture MD on Beam 2 (24th of June 2012)

    CERN Document Server

    Maclean, E H; Persson, T H B; Redaelli, S; Schmidt, F; Tomas, R; Uythoven, J

    2013-01-01

    This MD note summarizes measurements performed on LHC Beam 2 during the non-linear machine development (MD) of 24 June 2012. The aim of the measurement was to observe the dynamic aperture of LHC Beam 2, and obtain turn-by-turn (TbT) betatron oscillation data, enabling the study of amplitude detuning and resonance driving terms (RDTs). The regular injections required by the MD also represented an opportunity to test a new coupling feedback routine based on the analysis of injection oscillation data. Initial measurements were performed on the nominal state of the LHC at injection. On completion of this study the Landau octupoles were turned off and corrections for higher-order chromaticities were implemented to reduce the non-linearity of the machine as far as possible. A second set of measurements were then performed. All studies were performed using the LHC aperture kicker (MKA).

  19. Beam Diagnostics for the J-PARC Main Ring Synchrotron

    CERN Document Server

    Toyama, Takeshi; Hashimoto, Yoshinori; Hayashi, Naoki; Kishiro, Junichi; Lee, Seishu; Miura, Takako; Muto, Suguru; Toyokawa, Ryoji

    2005-01-01

    Beam diagnostics: beam intensity monitors (DCCT, SCT, FCT, WCM), beam position monitors (ESM), beam loss monitors (proportional chamber, air ion chamber), beam profile monitors (secondary electron emission, gas-sheet) have been designed, tested, and will be installed for the Main Ring synchrotron of J-PARC (Japan Proton Accelerator Research Complex). This paper describes the basic design principle and specification of each monitor, with a stress on how to cope with high power beam (average circulation current of ~12 A) and low beam loss operation (less than 1 W/m except a collimator region). Some results of preliminary performance test using present beams and a radiation source will be reported.

  20. Designing, manufacturing, and testing of embedded EFPI strain sensor for damage detection of smart composite beams

    Science.gov (United States)

    Sim, Lay M.; Zhou, Gang

    2005-04-01

    Designing a fiber optic sensor in the development of a real-time damage detection and evaluation system is important for providing reliable results. This paper describes the manufacturing and implementation of an Extrinsic Fabry-Perot Interferometer (EFPI) strain sensor for the non-destructive quantitative evaluation of carbon fiber reinforced composites. The EPFI strain sensors were examined for their integrity and performance. The integrity of the sensors was assessed experimentally by determining the bending strength of the glass tube, which was used in the fabrication of the sensor. Further validations on the survival of the sensors when embedded were also carried out with the application of the modified classical lamination theory (CLT). The sensor performance was examined extensively by either bonded on the surface or embedded in the tensile region of simple quasi-isotropic (QI) composite beams. These smart beams were loaded quasi-statically in three-point bend and cantilever loading The EFPI strain sensors have shown to surface a maximum tensile strain of up to 0.8%, which was adequate and reliable for strain measurements in the current system. The understanding of the EFPI strain sensors behaviour have paved way for the success in achieving a fiber optic strain sensor based damage detection and evaluation system (FODDAS).

  1. Oscillating flow loss test results in Stirling engine heat exchangers

    Science.gov (United States)

    Koester, G.; Howell, S.; Wood, G.; Miller, E.; Gedeon, D.

    1990-01-01

    The results are presented for a test program designed to generate a database of oscillating flow loss information that is applicable to Stirling engine heat exchangers. The tests were performed on heater/cooler tubes of various lengths and entrance/exit configurations, on stacked and sintered screen regenerators of various wire diameters and on Brunswick and Metex random fiber regenerators. The test results were performed over a range of oscillating flow parameters consistent with Stirling engine heat exchanger experience. The tests were performed on the Sunpower oscillating flow loss rig which is based on a variable stroke and variable frequency linear drive motor. In general, the results are presented by comparing the measured oscillating flow losses to the calculated flow losses. The calculated losses are based on the cycle integration of steady flow friction factors and entrance/exit loss coefficients.

  2. System Test of the ATLAS Muon Spectrometer in the H8 Beam at the CERN SPS

    CERN Document Server

    Etzion, Erez; 2004 IEEE Nuclear Science Symposium And Medical Imaging Conference; Etzion, Erez

    2004-01-01

    An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last four years. This spectrometer will use pressurized Monitored Drift Tube (MDT) chambers and Cathode Strip Chambers (CSC) for precision tracking, Resistive Plate Chambers (RPCs) for triggering in the barrel and Thin Gap Chambers (TGCs) for triggering in the end-cap region. The test set-up emulates one projective tower of the barrel (six MDT chambers and six RPCs) and one end-cap octant (six MDT chambers, A CSC and three TGCs). The barrel and end-cap stands have also been equipped with optical alignment systems, aiming at a relative positioning of the precision chambers in each tower to 30-40 micrometers. In addition to the performance of the detectors and the alignment scheme, many other systems aspects of the ATLAS muon spectrometer have been tested and validated with this setup, such as the mechanical detector integration and installation, the detector control system, the data acquisi...

  3. Pulse Shape Characterization of Silicon Diodes for HGCal with data from Beam Test at CERN

    CERN Document Server

    De Silva, Malinda

    2016-01-01

    The High Luminosity phase of the LHC (starting operation in 2025) will provide unprecedented instantaneous and integrated luminosity, with 25 ns bunch crossing intervals and up to 140 pileup events. A challenge is to provide excellent physics performance in such a harsh environment to fully exploit the HL-LHC potentialities and explore new physics frontiers. In this context, the High Granularity Calorimeter is the detector designed to provide electromagnetic and hadronic energy coverage and reconstruction in the forward direction of the upgraded CMS. In April 2016 and June 2016, a set of 36 diodes were tested in order to understand various characteristics of its performance, in order to use them in the upgraded HG Calorimeter. Here, the silicon diodes were mounted onto a test bench at CERN’s beam test area and exposed to electron showers. Data received from these diodes were acquired and analysed separately. The objective of this report is to show the variation of Time Rise, Time Over Threshold with various...

  4. An integral test of FLUKA nuclear models with 160 MeV proton beams in multi-layer Faraday cups

    CERN Document Server

    Rinaldi, I; Parodi, K; Ferrari, A; Sala, P; Mairani, A

    2011-01-01

    Monte Carlo (MC) codes are useful tools to simulate the complex processes of proton beam interactions with matter. In proton therapy, nuclear reactions influence the dose distribution. Therefore, the validation of nuclear models adopted in MC codes is a critical requisite for their use in this field. A simple integral test can be performed using a multi-layer Faraday cup (MLFC). This method allows separation of the nuclear and atomic interaction processes, which are responsible for secondary particle emission and the finite primary proton range, respectively. In this work, the propagation of 160 MeV protons stopping in two MLFCs made of polyethylene and copper has been simulated by the FLUKA MC code. The calculations have been performed with and without secondary electron emission and transport, as well as charge sharing in the dielectric layers. Previous results with other codes neglected those two effects. The impact of this approximation has been investigated and found to be relevant only in the proximity ...

  5. Thermo-Mechanical tests for the CLIC two-beam module study

    CERN Document Server

    Xydou, A; Riddone, G; Daskalaki, E

    2014-01-01

    The luminosity goal of CLIC requires micron level precision with respect to the alignment of the components on its two-meter long modules, composing the two main linacs. The power dissipated inside the module components introduces mechanical deformations affecting their alignment and therefore the resulting machine performance. Several two-beam prototype modules must be assembled to extensively measure their thermo-mechanical behavior under different operation modes. In parallel, the real environmental conditions present in the CLIC tunnel should be studied. The air conditioning and ventilation system providing specified air temperature and flow has been installed in the dedicated laboratory. The power dissipation occurring in the modules is being reproduced by the electrical heaters inserted inside the RF structure mock-ups and the quadrupoles. The efficiency of the cooling systems is being verified and the alignment of module components is monitored. The measurement results will be compared to finite elemen...

  6. Cement/bentonite interaction. Results from 16 month laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, O. [Clay Technology AB, Lund (Sweden)

    1997-12-01

    The work concerns possible bentonite clay mineral alteration in constructions with bentonite in close contact with cement, and the effect of such changes on bentonite buffer properties. The investigation comprises a 16 months laboratory test series with hydrothermal cell tests, percolation tests and diffusion tests. MX-80 Wyoming bentonite was used in all tests. Two types of artificial cement pore water solutions were used in the percolation and diffusion tests. The swelling pressure and the hydraulic conductivity were measured continuously in the percolation tests. After termination, the clay was analyzed with respect to changes in element distribution, mineralogy and shear strength. The water solutions were analyzed with respect to pH, cations and major anions. The results concerning chemical and mineralogical changes are in summary: Ion exchange in the montmorillonite until equilibrium with cement pore-water ions was reached; Increase in cation exchange capacity; Dissolution of original cristobalite; Increase in quartz content; Minor increase in illite content; Minor formation of chlorite; Formation of CSH(I); Wash away of CSH-gel into surrounding water. A large decrease in swelling pressure and a moderate increase in hydraulic conductivity were recorded in the samples percolated by SULFACEM pore-water solution. The mineralogical alterations only concerned a minor part of the total bentonite mass and the changes in physical properties were therefore most likely due to the replacement of the original charge balancing cation by cement pore-water cations. Comparisons between the current test result and results from 4 month tests indicate that the rates of illite and chlorite formation were reduced during the tests. The presence of zeolites in the clay could not be ensured. However, the discovery of CSH material is important since CSH is expected to precede the formation of zeolites 5 refs, 48 figs, 11 tabs

  7. Variables affecting interpretation of skin prick test results.

    Science.gov (United States)

    Topal, Suhan Günasti; Karaman, Bilge Fettahlıoğlu; Aksungur, Varol L

    2017-01-01

    Both performer- and device-dependent variabilities have been reported in sizes of wheal responses to skin prick tests. We aimed to evaluate whether or not variabilities in sizes of wheal responses influence the final interpretation of skin prick